Vous êtes sur la page 1sur 6

SUMMARY OF CHANGES

The 2007 Edition of this Code contains revisions in addition to the 2004 Edition with 2005 and 2006 Addenda. The revisions are identied with the designation 07 in the margin and, as described in the Foreword, become mandatory six months after the publication date of the 2007 Edition. To invoke these revisions before their mandatory date, use the designation 2007 Edition in documentation required by this Code. If you choose not to invoke these revisions before their mandatory date, use the designation 2004 Edition through the 2006 Addenda in documentation required by this Code. The BC numbers listed below are explained in more detail in List of Changes in BC Order following this Summary of Changes. Changes given below are identied on the pages by a margin note, 07, placed next to the affected area. Page 1 3 4 Location PG-2.1(a) PG-9.1 PG-9.1.2 PG-9.2 5 8 10
--`,,```,,,,````-`-`,,`,,`,`,,`---

Change (BC Number) Revised (BC06-1218) Added SA-333 (BC01-419) Added (BC03-214) Revised (BC00-433) Added (BC05-185) (1) Revised title and rst paragraph (BC03-214) (2) Added PG-12.2 and PG-12.3 (BC03-214) Revised in its entirety (BC06-959) Revised (BC05-1407) Two entries in the last column were revised (BC06-1493) Last row in in-text table added (BC05-185) (1) Revised (BC06-54) (2) PG-32.1.3.1.1 through PG-32.1.3.1.3 deleted (BC06-54) Paragraph designations corrected by errata (BC06-55) (1) Illustrations (d) and (e) revised (BC05-1119) (2) General Note (c) added (BC05-1119) ANSI revised to read ASME (BC06-747) Last sentence added (BC05-1485) Degree sign in Note (1)(c) corrected to be a percent sign by errata (BC06-55) Blow-Off Single and Multiple Installations line bolded by errata (BC06-744) Added (BC03-214) Revised (BC03-214) Revised (BC03-214) Revised (BC03-214) Revised (BC03-214) Revised (BC03-214) xxxiii

PG-9.7 PG-12 PG-18 PG-21

11 15 22

Table PG-19 PG-27.4, Note 6 PG-32.1.3.1

PG-32.1.4.3 27 30 31 33 41 45 Fig. PG-33.2 PG-39.5.1 PG-42.1.6 Fig. PG-42.1 Fig. PG-58.3.1 PG-60.1.1.4 PG-60.1.6 46 PG-60.3.2 PG-60.3.3 PG-60.3.6 PG-60.3.7

Copyright ASME International Provided by IHS under license with ASME No reproduction or networking permitted without license from IHS

Not for Resale

Page 47 52 60

Location PG-60.6.4 PG-68.3 PG-73.3.4(b) PG-73.3.4(b)(1) PG-73.3.4(b)(5) PG-73.3.4(c)

Change (BC Number) Spelling of Celsius corrected by errata (BC06-55) Revised (BC04-926, BC06-748) Revised (BC05-1655) Revised (BC05-1655) Revised (BC05-1655) Added (BC05-1655) Revised in its entirety (BC02-3580) Revised in its entirety (BC02-3580) PG-100 deleted (BC06-959) Revised (BC04-926) Revised (BC06-1354) Revised in its entirety (BC06-1353) Revised (BC05-556) General Note (h) revised (BC05-1248) Equations revised (BC05-556) Revised (BC05-556) Illustration (q-2) revised (BC05-656) (1) General Note (a)(11)(f) added (BC05-1248) (2) General Note (a)(12) added (BC05-682) General Note (a)(8)(c)(3) added (BC05-682) General Note (a)(6)(e) added (BC05-682) (1) General Note (a)(5) added (BC05-682) (2) General Note (a)(6) added (BC05-1608) P-No. 10H added (BC05-185) Revised (BC06-745) (1) PWT-11.1(e) added (BC04-1431) (2) Last sentence revised (BC04-1431) Illustration (e) added (BC04-1431) Title revised (BC05-1248) First and last sentences revised (BC05-1248) Last sentence deleted (BC05-1248) First sentence revised (BC04-1192) Added (BC04-1288) First sentence revised (BC06-749) Revised (BC06-1084) Two values in the rst number column corrected by errata (BC06-55) Revised (BC06-1345) (1) A-317.3(c)(4) deleted (BC06-1345) xxxiv
Not for Resale

61

PG-73.4.1 PG-73.4.3

63 69 71 74 78 79 80 81 83 92 93 94 95 99 103 119 122 130

Inspection and Tests PG-106.4.2(e) PG-108.2 PG-112.2.7 PW-15.1 Table PW-11 Fig. PW-15 PW-15.1.2 Fig. PW-16.1 Table PW-39 Table PW-39 Table PW-39 Table PW-39 Table PW-39 PW-41.5 PWT-11.1 Fig. PWT-11 Fig. PFT-21 PFT-21.1 PFT-21.2

147 151, 152 162 163 168 191 192

PEB-18.2.2 Part PHRSG A-19.3 A-20.3 Table A-44 A-317.1 A-317.3


--`,,```,,,,````-`-`,,`,,`,`,,`---

Copyright ASME International Provided by IHS under license with ASME No reproduction or networking permitted without license from IHS

Page

Location

Change (BC Number) (2) A-317.3(h) deleted (BC06-1345)

194 195, 196 198

Form P-2 Form A-351 Form P-2A

New header added (BC06-570) (1) Last sentence added to number 5 (BC06-570) (2) Number 41 added (BC06-570) (1) New header added (BC06-570) (2) Certied Individual checkbox added to Certicate of Compliance of Completed Boiler box (BC04-1192) (3) Number 33 added to Certicate of Shop Inspection of Completed Boiler head (BC04-1192) (1) Last sentence added to number 5 (BC06-570) (2) Number 32 revised (BC04-1192) (3) Number 36 added (BC06-570) New header added (BC06-570) (1) Last sentence added to numbers 6 through 8 (BC06-570) (2) Number 48 added (BC06-570) New headers added (BC06-570) (1) Last sentence to number 5 added (BC06-570) (2) Number 36 added (BC06-570) (1) New header added (BC06-570) (2) Form P-3A-M deleted by errata (BC07-410) (1) Last sentence added to number 4 (BC06-570) (2) Number 16 added (BC06-570) New header added (BC06-570) (1) Number 32 revised (BC06-570) (2) Paragraph designation in number 34 corrected by errata (BC06-55) (3) Number 35 added (BC06-570) New header added (BC06-570) (1) Number 23 revised (BC06-570) (2) Number 24 added (BC06-570) Number 17 revised to read 18 in rst line (BC06-570) Number 18 revised (BC06-570) New header added (BC06-570) (1) Number 2 revised (BC06-570) (2) Number 19 added (BC06-570) Table A-361 deleted (BC05-379) (1) B16.34a-1998 revised to read B16.34-2004 (BC05-379) (2) B31.1-2004 revised to read B31.1b-2006 (BC06-849) (3) B36.10M-2000 revised to read B36.10M-2004 (BC05-925) (4) Note (1) deleted (BC05-379) (5) Note (5) deleted (BC06-1325)

199, 200

Form A-351.1

202 203, 204

Form P-2B Form A-351.2

206, 207 208, 209 211


--`,,```,,,,````-`-`,,`,,`,`,,`---

Form P-3 Form A-352 Form P-3A Form A-353 Form P-4 Form A-354

212 214 215

218 219 220 221 226 227 231 232

Form P-4A Form A-354.1 Form P-4B Form A-354.2 Form P-7 Form A-356 A-360 Table A-360

NOTE: Volume 57 of the Interpretations to Section I of the ASME Boiler and Pressure Vessel Code follows the last page of this Edition. xxxv
Copyright ASME International Provided by IHS under license with ASME No reproduction or networking permitted without license from IHS Not for Resale

LIST OF CHANGES IN BC ORDER


BC Number
BC00-433 BC01-419 BC02-3580 BC03-214 BC04-1192

Change
Revised Sections I, II, III, VIII, IX, and XII and Code Cases 21-217-1, 2224-1, N-201-4, and N-253 to change references to SA-336 for stainless steel forgings to SA-965. Incorporation of SA-333 Grade 6 carbon steel from Code Case 2056-1 into Section I and Section II, Part D, and annulment of the Code Case 6 months after publication of the revision. PG-73.4.1 Revised hydrostatic test requirement. PG-73.4.3 Revised footnote. Revised PG-9, PG-12, and PG-60 to include permitted materials for use in magnetic water level indicators and provisions for their use. Revised para. PEB-18.2.2 to provide for periodic audits of S and M stamp holder, as well as E stamp holders who elect to make an equivalent examination of a completed electric boiler without witness by the Authorized Inspector as permitted in paras. PEB-18.1 and PEB-18.5. New Part PHRSG, Requirements for Heat Recovery Steam Generators. Revised PWT-11.1 to allow the attachment of tubes in water tube boiler by expansion only into tube holes with grooved sides. Added sketch (e) to Fig. PWT-11 to illustrate the requirements for expanding a tube into grooved tube holes. 1. Revised PG-59.4 to delete integral ahead of economizers. 2. Proposed revisions to PG-68.3 and PG-106.4.2(e) add isolable superheaters to safety valve requirements and to nameplate stamping requirements. Also, in PG-106.4.2(e), independently is replaced with isolable and nonintegral separately red superheaters, which are the type that require separate namepletes. Added 30 deg min. transition angle to illustrations (d) and (e), and add Note (c) to Fig. PG-33.2 per the Annex. Illustration (d) was revised to show a single 60 deg angle, as is the case in illustrations (g) and (h) of Fig. PG-33.2. Revised Table PW-11 to add the existing exemptions from RT for waterleg, furnace, and rebox weld joints, removing them from PFT-21. Revised Table PW-39 for P-No.1 to permit exemption from PWHT for waterleg, rebox, and furnace welds complying with PFT-21, which do not exceed 34 in. (19 mm) in thickness. Revised PFT-21.1 and PFT-21.2 to delete radiography exemptions, which have been relocated to Table PW-11 and to clarify where the waterleg width dimension requirements apply. Also, claried the intent that other waterleg closure designs which meet the requirements are acceptable by adding a new nal sentence to PFT-21.1 and changing the title of Fig. PFT-21 to add the words Some Acceptable at the beginning. Deleted reference to units of measure. Addition of the following sentence to PG-42.1.6: Parts such as lap joint stub ends fabricated by welding with ller metal added may not be used in Code Construction unless they are fabricated in accordance with PG-11.3. Revised Table PW-39 for P-No.5A to add Note (1)(e), adding an exemption from PWHT for corrosion resistant overlay welding of pipe and tube under qualifying conditions. Incorporated CC 2208 by revising PG-73.3.4 to include the application of a corrosion-resistant coating to valve springs to the permissable modications by an Assembler. Revised Section I, paras. PG-9.7, PG-27.4, PW-39; Section II, Part D; and Table 1A all revised to incorporate Alloy S31803. Added new Part PHRSG to protect hot coils from desuperheater spray water quenching. Also added new Fig. PHRSG-4. Table A-360 was revised to refer to B16.34-2004, Valves Flanged, Threaded, and Welding End, and to delete Note 1, referenced for both B16.5 and B16.34. Table A-361 was deleted. Revised PW-15.1 to call for use of smaller weld leg when llet weld legs are unequal. Revise PW-15.1.2 and Fig. PW-15 to use average diameter when calculating strength of llet welds. Revised Table PW-39 PWHT requirements for P-No.1, P-No.3, P-No.4, and P-No.5A, permitting the attachment of nonload bearing studs and insulation attachment pins to heat-absorbing surfaces when using an automatic arc stud welding or automatic resistance stud welding processes. Updated Table A-360 for reference to Standard B16.10M. Corrected the reference to gure on fusible plugs in A20.3 The revision claries the denition of Power Boiler as used in BPV SC-I. Table A-360 revised to delete Note 5 and editorially correct reference paragraphs in Notes 2 and 6. Note 5 is no longer needed because of revisions made to ASME B31.1. The wording unless the formula is noted otherwise is removed from A-317.1. Also, paras. A-317.3(c)(4) and A-317.3(h) are removed.

BC04-1288 BC04-1431

BC04-926

BC05-1119

BC05-1248

BC05-1407 BC05-1485

BC05-1608 BC05-1655 BC05-185 BC05-186 BC05-379 BC05-556 BC05-682

BC05-925 BC06-1084 BC06-1218 BC06-1325 BC06-1345

xxxvi
Copyright ASME International Provided by IHS under license with ASME No reproduction or networking permitted without license from IHS Not for Resale

--`,,```,,,,````-`-`,,`,,`,`,,`---

BC Number
BC06-1353 BC06-1354 BC06-1493 BC06-54 BC06-55 BC06-566 BC06-57 BC06-570

Change
The rst sentence of PG-112.2.7 was revised. Statement added to PG-108.2 to identify where the additional nameplate must be located. This proposal corrects the metricated values in Table PG-19. Revised PG-32.1.3.1 using 238 in. in leiu of NPS 2, and combined paras. PG-32.1.3.1.1, PG32.1.3.1.2, and PG-32.1.3.1.3 into PG-32.1.3.1. Errata items for Section I. Added new certication rules to Part PHRSG. Paragraph references corrected editorially. 1. Added Page (Ref. No.) of (Ref. No.) to selected forms. This is the page number and total number of pages for the individual form. 2. On the second and third pages, where applicable, of the form, the following changes were made: (a) Added Page (Ref. No.) of (Ref. No.) on form. This is the page number and total number of pages for the individual form. (b) Deleted the word Back or Back (Contd) on form. (c) Added method of identication of the boiler from the rst page of the form. 3. On Forms P-4B and P-4B-M, changed the reference to number 17 on line 1 of the form to number 18. On the guides, the following changes were made: (a) Added a statement to the boiler identication numbers being used, To be shown on all pages of Forms P-X and P-X, as appropriate. (b) Added reference number and statement, Show page number and total number of pages of Forms P-X or P-X, as appropriate. (c) On Guides for Forms P-4, P-4M, P-4A, P-4A-M, P-4B, P-4B-M, P-7, and P-7M, deleted the words If desired, capitalized the letter T, and changed the word may to shall. Corrected Fig. PW-16.1, sketch (q-2) dimension 12t sub min. to minimum of 112t. Errata to Fig. PG-58.3.1, bolded line under PG-58.3.6. Added references to PW-41.5.4 through PW-41.5.6 in PW-41.5. Corrected the B1.20.1 reference in PG-39.5.1. Replaced the text 6 lb (29 kg/hr) of steam per square foot (square meter) of with 6 lb/ft2 (29 kg/m2) of steam per hour, using the for greater clarity. Replaced the word renewed with replaced in rst sentence. Updated Table A-360 for the 2007 edition. Deleted para. PG-100 and the last ten words of PG-18. Deleted Form P-3A-M by errata.

Copyright ASME International Provided by IHS under license with ASME No reproduction or networking permitted without license from IHS

--`,,```,,,,````-`-`,,`,,`,`,,`---

BC06-656 BC06-744 BC06-745 BC06-747 BC06-748 BC06-749 BC06-849 BC06-959 BC07-410

xxxvii
Not for Resale

xxxviii
Copyright ASME International Provided by IHS under license with ASME No reproduction or networking permitted without license from IHS Not for Resale

--`,,```,,,,````-`-`,,`,,`,`,,`---

Vous aimerez peut-être aussi