CONTENTS
Bostmarine Type LSX Power Cable Four Conductor

.............................................................................................
1

Bostmarine Type LSX Power Cable Multi-Conductor

............................................................................................
3

Bostmarine Type LSX Power Cable Three Conductor


Bostmarine Type LSX Power Cable Two Conductor

...........................................................................................
5

.............................................................................................
7

Bostmarine Type LSX Signal Cable 16 AWG

........................................................................................................
9

Bostmarine Type LSX Signal Cable 18 AWG

........................................................................................................
11

Bostmarine Type LSX Signal Cable 20 AWG

........................................................................................................
13

Bostmarine Type T/N Control Cable Multi-Conductor

............................................................................................
15

Bostmarine Type T/N Control Cable Multi-Conductor Shielded

.............................................................................
17

Bostmarine Type T/N Control Cable Shielded Triads

............................................................................................
19

Bostmarine Type T/N Power Cable Four Conductor

..............................................................................................
21

Bostmarine Type T/N Power Cable Three Conductor

............................................................................................
23

Bostmarine Type T/N Power Cable Two Conductor

..............................................................................................
25

Bostmarine Type T/N Signal Cable 14 AWG

.........................................................................................................
27

Bostmarine Type T/N Signal Cable 16 AWG

.........................................................................................................
29

Bostmarine Type T/N Signal Cable 18 AWG

.........................................................................................................
31

Bostmarine Type T/N Signal Cable 20 AWG

.........................................................................................................
33

Bostmarine Type X Control Cable

..........................................................................................................................
35

Bostmarine Type X Power Cable Four Conductor

.................................................................................................
37

Bostmarine Type X Power Cable Three Conductor

...............................................................................................
39

Bostmarine Type X Power Cable Two Conductor

..................................................................................................
41

Bostmarine Type X Signal Cable 16 AWG

.............................................................................................................
43

Bostmarine Type X Signal Cable 18 AWG

.............................................................................................................
45

Bostmarine Type X Signal Cable 20 AWG

.............................................................................................................
47

Bostrig 125 Type P Control 10&12AWG

................................................................................................................
49

Bostrig 125 Type P Control 12&10AWG

................................................................................................................
51

Bostrig 125 Type P Control 14AWG

......................................................................................................................
53

Bostrig 125 Type P Control 14AWG AS


Bostrig 125 Type P Control 16AWG

.................................................................................................................
55

......................................................................................................................
57
II

CONTENTS
Bostrig 125 Type P Control 16AWG AS
Bostrig 125 Type P Control 18AWG

.................................................................................................................
59

......................................................................................................................
61

Bostrig 125 Type P Control 18AWG AS


Bostrig 125 Type P MR Power Cable
Bostrig 125 Type P Power 1C

..........................................................................................................................
77

............................................................................................................................
79

Bostrig 125 Type P Power 4C AS


Bostrig 125 Type P Power 5C

..........................................................................................................................
73

............................................................................................................................
75

Bostrig 125 Type P Power 3C AS


Bostrig 125 Type P Power 4C

..........................................................................................................................
69

............................................................................................................................
71

Bostrig 125 Type P Power 2C AS


Bostrig 125 Type P Power 3C

....................................................................................................................
65

............................................................................................................................
67

Bostrig 125 Type P Power 1C AS


Bostrig 125 Type P Power 2C

.................................................................................................................
63

..........................................................................................................................
81

............................................................................................................................
83

Bostrig 125 Type P Power 5C AS

..........................................................................................................................
85

Bostrig 125 Type P Signal Cable

...........................................................................................................................
87

Bostrig 125 Type P Signal Cable

...........................................................................................................................
89

Bostrig 125 Type P Signal IO P 16&14AWG

.........................................................................................................
91

Bostrig 125 Type P Signal IO P 16&14AWG AS


Bostrig 125 Type P Signal IO P 20&18AWG

.........................................................................................................
95

Bostrig 125 Type P Signal IO P 20&18AWG AS


Bostrig 125 Type P Signal IO T 18&16AWG

....................................................................................................
97

..........................................................................................................
99

Bostrig 125 Type P Signal IO T 18&16AWG AS


Bostrig 125 Type P VFD 2kV

....................................................................................................
93

....................................................................................................
101

............................................................................................................................
103

Bostrig MHV-15 Cable IEC 12/20 kV

.....................................................................................................................
105

Bostrig MHV-15 Cable IEC 8.7/15 kV

....................................................................................................................
106

Bostrig MHV-15B Cable 100% Level

.....................................................................................................................
107

Bostrig MHV-15B Cable 133% Level

.....................................................................................................................
108

Bostrig MHV-15BS Cable IEC 12/20 kV

................................................................................................................
109

Bostrig MHV-15BS Cable IEC 8.7/15 kV

...............................................................................................................
110
III

CONTENTS
Bostrig MHV-5 Cable

............................................................................................................................
111

Bostrig MHV-5B Cable

............................................................................................................................
112

Bostrig MHV-5BS Cable

............................................................................................................................
113

Bostrig MHV-8 Cable IEC 3.6/6 kV

........................................................................................................................
114

Bostrig MHV-8 Cable IEC 6/10 kV

.........................................................................................................................
115

Bostrig MHV-8B Cable 100% Level

.......................................................................................................................
116

Bostrig MHV-8B Cable 133% Level

.......................................................................................................................
117

Bostrig MHV-8BS Cable IEC 3.6/6 kV

...................................................................................................................
118

Bostrig MHV-8BS Cable IEC 6/10 kV

....................................................................................................................
119

Bostrig MHV3-15 Cable IEC 12/20 kV

...................................................................................................................
120

Bostrig MHV3-15 Cable IEC 8.7/15 kV

..................................................................................................................
121

Bostrig MHV3-15B Cable 100% Level

...................................................................................................................
122

Bostrig MHV3-15B Cable 133% Level

...................................................................................................................
123

Bostrig MHV3-15BS Cable IEC 12/20 kV

..............................................................................................................
124

Bostrig MHV3-15BS Cable IEC 8.7/15 kV

.............................................................................................................
125

Bostrig MHV3-5 Cable

............................................................................................................................
126

Bostrig MHV3-5B Cable


Bostrig MHV3-5BS Cable

............................................................................................................................
127
............................................................................................................................
128

Bostrig MHV3-8 Cable IEC 3.6/6 kV

......................................................................................................................
129

Bostrig MHV3-8 Cable IEC 6/10 kV

.......................................................................................................................
130

Bostrig MHV3-8B Cable 100% Level

.....................................................................................................................
131

Bostrig MHV3-8B Cable 133% Level

.....................................................................................................................
132

Bostrig MHV3-8BS Cable IEC 3.6/6 kV

.................................................................................................................
133

Bostrig MHV3-8BS Cable IEC 6/10 kV

..................................................................................................................
134

Bostrig S611T Marine Fiber Optic Cables

..............................................................................................................
135

Bostrig S670 T Marine Fiber Optic Cables

.............................................................................................................
137

Datacomm 50 Coaxial cable - 2.7/7.3AF Low Loss FRNC-C

...........................................................................
139

Datacomm 50 Coaxial cable - RG 213 FRNC-B

................................................................................................
141

Datacomm 50 Coaxial cable - RG 214 FRNC-B

................................................................................................
143

IV

CONTENTS
Datacomm 50 Coaxial cable - RG 214 PVC

......................................................................................................
145

Datacomm 50 Coaxial cable - RG 223 FRNC-B


Datacomm 50 Coaxial cable - RG 223 PVC

................................................................................................
147

......................................................................................................
149

Datacomm 6 FOILS 4x2x0.57 (AWG 23) MULTIMEDIA LSHF-FR


Datacomm 75 CATV cable - 1.0/4.8 AF FRNC-C
Datacomm 75 CATV cable - 1.6/7.3 AF FRNC

..............................................................................................
153

..................................................................................................
155

Datacomm 75 CATV cable - Coax10 AD 10S FRNC-C

.....................................................................................
157

Datacomm Analogue Audio Cable 110 O AC10 SS 26/7 10P


Datacomm Armoured industrial cable AICI-I/O/RM-W

...............................................................................
159

...........................................................................................
161

Datacomm Cat. 5e SF/UTP 4x2x0.51 (AWG 24) FRNC-C

....................................................................................
163

Datacomm Cat. 7 S/FTP 4x2x0.42 (AWG 27/7) Patch LSHF


Datacomm Cat. 7 S/FTP 4x2x0.56 (AWG 23) LSHF

................................................................................
165

.............................................................................................
167

Datacomm Optical Fire Resistant Cable QFCI-I/O/RM/C-JM


Datacomm S611T Marine Fiber Optic Cable

.......................................................................
151

................................................................................
169

.........................................................................................................
171

Datacomm S670T Armoured Marine Fiber Optic Cable

........................................................................................
173

Datacomm SIENOPYR-FR-PROFIBUS M-02Y(St)CHX 100V

..............................................................................
175

Datacomm ToughCat S/STP 4x2x0,6 (AWG 24/7) LSHF-FR

............................................................................
177

HXXM CL2 1KV

............................................................................................................................
179

HXXM CL5 1KV

............................................................................................................................
181

HXXM FR CL2 1KV

............................................................................................................................
183

HXXM FR CL5 1KV

............................................................................................................................
184

HXXM FR Power & Control


HXXM(i) 1kV
HXXM(i) 250V

............................................................................................................................
186

............................................................................................................................
188
............................................................................................................................
190

HXXMB 1KV CL5 armoured

............................................................................................................................
192

HXXMB FR CL2 1KV armoured

............................................................................................................................
194

HXXMB FR CL5 1KV armoured

............................................................................................................................
196

HXXMB(c) FR 1KV armoured


HXXMB(i) 1kV armoured

............................................................................................................................
198

............................................................................................................................
200
V

CONTENTS
HXXMB(i) 250V armoured

............................................................................................................................
202

HXXMB(i) FR 1kV armoured


HXXMB(i) FR 250V armoured
BFOU 1kV

............................................................................................................................
204
............................................................................................................................
206

............................................................................................................................
208

BFOU(c) 250V

............................................................................................................................
220

BFOU(i) 250V

............................................................................................................................
224

BFOU-HCF(c) 250V

............................................................................................................................
229

BFOU-HCF(i) 250V

............................................................................................................................
231

BFOU-HCF-1kv-HF

............................................................................................................................
233

BU 1kV

............................................................................................................................
238

BU(c) 250V

............................................................................................................................
242

BU(i) 250V

............................................................................................................................
245

RFOU 12 20 24kV
RFOU 1kV

............................................................................................................................
248

............................................................................................................................
251

RFOU 6 10 12kV

............................................................................................................................
263

RFOU(c) 250V

............................................................................................................................
267

RFOU(i) 250V

............................................................................................................................
271

RFOU-HCF-6_10_12kV-HF
RU 1kV

............................................................................................................................
276

............................................................................................................................
279

RU(c) 250V

............................................................................................................................
285

RU(i) 250V

............................................................................................................................
288

UX 1000V

............................................................................................................................
291

Shipline BI 1KV

............................................................................................................................
293

Shipline BXOI 1KV

............................................................................................................................
296

Shipline BXOI 250V

............................................................................................................................
300

Shipline TFOI 12KV

............................................................................................................................
303

Shipline TI 1KV

............................................................................................................................
305

Shipline TI(c) 1KV

............................................................................................................................
311

Shipline TXOI 1KV

............................................................................................................................
314
VI

CONTENTS
Shipline TXOI 250V

............................................................................................................................
320

Shipline Plus TFXI 1KV

............................................................................................................................
323

Shipline Plus TIOI(c) 250V armoured


Shipline TFOI 10KV amoured
Shipline TIOI 1KV armoured
BFCU 1kV

....................................................................................................................
329

............................................................................................................................
332
............................................................................................................................
334

............................................................................................................................
340

BFCU(c) 250V

............................................................................................................................
344

BFCU(i) 250V

............................................................................................................................
348

RFCU 1kV

............................................................................................................................
353

RFCU(c) 250V

............................................................................................................................
357

RFCU(i) 250V

............................................................................................................................
361

RU 1kV

............................................................................................................................
365

RU 1kV earthing cable

............................................................................................................................
367

This catalog represents only a partial selection of Draka Marine, Oil & Gas International wire and
cable products, based on criteria submitted when requesting the information. For a complete list
of Draka Marine, Oil & Gas International products, including specialty conversion and termination
items, visit www.DrakaMOG.com.
All products are subject to current availability. Please check with your Draka Marine, Oil & Gas
International representative.

All contents 2007 Draka Marine, Oil & Gas International. All rights reserved.

VII

Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX POWER CABLE


four conductor / LSZH / unarmored & armored
14 AWG to 500 MCM / 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applications where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness as
shown in tables on the reverse.

3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (covered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.

CustRef LSX-05

DUSA_LSX05_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-502

BOSTMARINE TYPE LSX POWER CABLE


four conductor / LSZH / unarmored
14 AWG to 500 MCM / 600V
TPC
Cable Type

Part
Number

Conductor
Size

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

FLSXTPO-4
FLSXTPO-6
FLSXTPO-10
FLSXTPO-16
FLSXTPO-26
FLSXTPO-41
FLSXTPO-66
FLSXTPO-83
FLSXTPO-106
FLSXTPO-133
FLSXTPO-168
FLSXTPO-212
FLSXTPO-250
FLSXTPO-300
FLSXTPO-350
FLSXTPO-400
FLSXTPO-500

036338
036339
036340
036341
036342
036343
036344
036345
036346
036347
036348
036349
036350
036351
036352
036353
036354

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65

0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79

0.440 11.2
0.485 12.3
0.575 14.6
0.730 18.5
0.830 21.1
0.990 25.1
1.140 29.0
1.290 32.8
1.390 35.3
1.500 38.1
1.625 41.3
1.830 49.5
2.000 50.8
2.130 54.1
2.260 57.4
2.370 60.2
2.580 65.5

120 179
164 244
241 359
382 568
542 806
824 1226
1205 1793
1500 2232
1782 2652
2220 3303
2706 4027
3444 5125
4002 5955
4680 6964
5464 8130
6140 9136
7560 11250

four conductor / LSZH / aluminum or bronze armored


14 AWG to 500 MCM / 600V
TPC
Cable Type

Part
Number*

Conductor
Size

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

FLSXTPO-4
FLSXTPO-6
FLSXTPO-10
FLSXTPO-16
FLSXTPO-26
FLSXTPO-41
FLSXTPO-66
FLSXTPO-83
FLSXTPO-106
FLSXTPO-133
FLSXTPO-168
FLSXTPO-212
FLSXTPO-250
FLSXTPO-300
FLSXTPO-350
FLSXTPO-400
FLSXTPO-500

036338
036339
036340
036341
036342
036343
036344
036345
036346
036347
036348
036349
036350
036351
036352
036353
036354

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65

0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79

0.495 12.6
0.540 13.7
0.630 16.0
0.785 19.9
0.885 22.5
1.045 26.5
1.195 30.4
1.345 34.2
1.445 36.7
1.555 39.5
1.680 42.7
1.885 47.9
2.055 52.2
2.185 55.5
2.315 58.8
2.425 61.6
2.635 66.9

147 219
193 287
276 411
426 634
591 879
882 1312
1272 1893
1576 2345
1863 2772
2308 3434
2801 4168
3551 5284
4118 6128
4804 7148
5595 8325
6278 9342
7710 11472

209 311
262 390
356 530
526 783
705 1049
1017 1513
1427 2123
1750 2604
2051 3052
2501 3721
3020 4494
3797 5650
4387 6528
5090 7574
5899 8778
6595 9813
8055 11986

*NOTE: For aluminum armored versions, add an A (ex. 036299A). For bronze armored versions, add a B (ex. 036299B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-06

Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX CONTROL CABLE


multi-conductor / LSZH / unarmored & armored
18, 16 and 14 AWG / 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applications where low smOke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness as
shown in tables on the reverse.

3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (covered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.

CustRef LSX-07

DUSA_LSX07_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-502

BOSTMARINE TYPE LSX CONTROL CABLE


multi-conductor / LSZH / armored & unarmored
18, 16 and 14 AWG / 600V
18 AWG 1.0 mm2
TPC
Cable Type

Part
Number of Stranding
Number* Conductors Type

C18LSXTPO-2
C18LSXTPO-3
C18LSXTPO-4
C18LSXTPO-7
C18LSXTPO-10
C18LSXTPO-14
C18LSXTPO-19
C18LSXTPO-24
C18LSXTPO-30
C18LSXTPO-37
C18LSXTPO-44
C18LSXTPO-61

036355*
036356*
036357*
036358*
036359*
036360*
036361*
036362*
036363*
036364*
036365*
036366*

2
3
4
7
10
14
19
24
30
37
44
61

7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2

Insulation
Thickness
in mm

Jacket
Thickness
in mm

0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

Insulation
Thickness
in mm

Jacket
Thickness
in mm

0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

Insulation
Thickness
in mm

Jacket
Thickness
in mm

0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

Cable Diameter Cable Weight


Armored Cable
(nom)
(approx)
Diameter (nom)
in mm Lbs/mft Kg/km
in mm
0.32 8.0
0.33 8.4
0.36 9.1
0.42 10.8
0.56 14.4
0.61 15.5
0.67 17.0
0.78 19.8
0.88 22.4
0.93 23.6
1.03 26.2
1.10 27.9

47 70
56 83
68 101
99 147
153 228
195 290
250 372
308 458
370 551
480 714
547 814
696 1036

0.375 9.5
0.385 9.8
0.415 10.5
0.475 12.1
0.615 15.6
0.665 16.9
0.725 18.4
0.835 21.2
0.935 23.7
0.985 25.0
1.085 27.6
1.155 29.3

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
67 100
77 115
90 133
125 186
187 279
232 345
290 432
354 527
422 628
535 796
608 905
761 1132

113 168
124 185
142 211
184 274
265 394
316 470
383 570
462 687
543 808
662 985
748 1113
910 1354

16 AWG 1.3 mm2


TPC
Cable Type

Part
Number of Stranding
Number* Conductors Type

C16LSXTPO-2
C16LSXTPO-3
C16LSXTPO-4
C16LSXTPO-7
C16LSXTPO-10
C16LSXTPO-14
C16LSXTPO-19
C16LSXTPO-24
C16LSXTPO-30
C16LSXTPO-37
C16LSXTPO-44
C16LSXTPO-61

036367*
036368*
036369*
036370*
036371*
036372*
036373*
036374*
036375*
036376*
036377*
036378*

2
3
4
7
10
14
19
24
30
37
44
61

7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2

Cable Diameter Cable Weight


Armored Cable
(nom)
(approx)
Diameter (nom)
in mm Lbs/mft Kg/km
in mm
0.34 8.6
0.36 9.1
0.39 9.9
0.46 11.7
0.61 15.6
0.67 16.9
0.73 18.7
0.90 22.9
0.95 24.1
1.02 25.9
1.16 29.3
1.27 32.4

57 85
71 106
87 129
129 192
197 293
255 379
328 488
444 661
529 787
631 939
748 1113
980 1458

0.395 10.0
0.415 10.5
0.445 11.3
0.515 13.1
0.665 16.9
0.725 18.4
0.785 19.9
0.955 24.5
1.055 26.8
1.075 27.3
1.215 30.9
1.325 33.7

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
78 116
93 138
111 165
157 234
234 348
295 439
372 553
497 740
585 870
691 1028
816 1214
1054 1568

127 189
145 216
167 248
222 330
318 473
388 577
472 702
620 922
715 1064
830 1235
974 1449
1227 1826

14 AWG 2.1 mm2


TPC
Cable Type

Part
Number of Stranding
Number* Conductors Type

C14LSXTPO-2
C14LSXTPO-3
C14LSXTPO-4
C14LSXTPO-7
C14LSXTPO-10
C14LSXTPO-14
C14LSXTPO-19
C14LSXTPO-24
C14LSXTPO-30
C14LSXTPO-37
C14LSXTPO-44
C14LSXTPO-61

036379*
036380*
036381*
036382*
036383*
036384*
036385*
036386*
036387*
036388*
036389*
036390*

2
3
4
7
10
14
19
24
30
37
44
61

7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2

Cable Diameter Cable Weight


Armored Cable
(nom)
(approx)
Diameter (nom)
in mm Lbs/mft Kg/km
in mm
0.37 9.4
0.39 9.9
0.42 10.8
0.51 12.8
0.68 17.1
0.73 18.5
0.81 20.6
0.99 25.1
1.05 26.7
1.13 28.7
1.27 32.3
1.40 35.4

72 107
92 137
114 170
173 257
261 388
342 509
444 661
593 882
714 1063
856 1274
1010 1503
1350 2009

0.425 10.8
0.445 11.3
0.475 12.1
0.565 14.3
0.735 18.7
0.785 19.9
0.865 22.0
1.045 26.5
1.105 28.1
1.185 30.1
1.325 33.7
1.455 37.0

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
95 141
116 173
140 208
204 304
302 449
386 574
492 732
651 967
776 1155
922 1372
1084 1613
1432 2130

148 220
172 256
199 296
275 409
396 589
486 723
603 897
786 1170
919 1367
1076 1601
1257 1870
1621 2412

*NOTE: For aluminum armored versions, add an A (ex. 036379A). For bronze armored versions, add a B (ex. 036079B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-08

Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX POWER CABLE


three conductor / LSZH / unarmored & armored
14 AWG to 1000 MCM / 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applications where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness as
shown in tables on the reverse.

3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (covered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.

CustRef LSX-03

DUSA_LSX03_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-502

BOSTMARINE TYPE LSX POWER CABLE


three conductor / LSZH / unarmored
14 AWG to 1000 MCM / 600V
TPC
Cable Type

Part
Number

Conductor
Size

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TLSXTPO-4
TLSXTPO-6
TLSXTPO-10
TLSXTPO-16
TLSXTPO-26
TLSXTPO-41
TLSXTPO-66
TLSXTPO-83
TLSXTPO-106
TLSXTPO-133
TLSXTPO-168
TLSXTPO-212
TLSXTPO-250
TLSXTPO-300
TLSXTPO-350
TLSXTPO-400
TLSXTPO-500
TLSXTPO-750
TLSXTPO-1000

036319
036320
036321
036322
036323
036324
036325
036326
036327
036328
036329
036330
036331
036332
036333
036334
036335
036336
036337

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
750 380.0
1000 507.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/110.9
61/128.0

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.080 2.03
0.080 2.03

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.140 3.56
0.140 3.56

0.400 10.2
0.440 11.2
0.500 12.7
0.670 17.1
0.750 19.1
0.900 23.0
1.030 26.2
1.160 29.5
1.255 31.9
1.355 34.4
1.470 37.3
1.595 40.5
1.810 46.0
1.930 49.0
2.040 51.8
2.140 54.4
2.330 59.2
2.865 72.8
3.200 81.3

90 134
120 179
170 253
280 417
395 588
570 848
875 1302
1090 1622
1320 1964
1615 2403
1980 2947
2435 3624
2965 4412
3485 5186
4005 5960
4525 6734
5545 8252
8420 12530
11000 16370

three conductor / LSZH / aluminum and bronze armored


14 AWG to 1000 MCM / 600V
TPC
Cable Type

Part
Number*

Conductor
Size

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

TLSXTPO-4
TLSXTPO-6
TLSXTPO-10
TLSXTPO-16
TLSXTPO-26
TLSXTPO-41
TLSXTPO-66
TLSXTPO-83
TLSXTPO-106
TLSXTPO-133
TLSXTPO-168
TLSXTPO-212
TLSXTPO-250
TLSXTPO-300
TLSXTPO-350
TLSXTPO-400
TLSXTPO-500
TLSXTPO-750
TLSXTPO-1000

036319
036320
036321
036322
036323
036324
036325
036326
036327
036328
036329
036330
036331
036332
036333
036334
036335
036336
036337

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
750 380.0
1000 507.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/110.9
61/128.0

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.080 2.03
0.080 2.03

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.140 3.56
0.140 3.56

0.455 11.3
0.495 12.6
0.555 14.1
0.725 18.4
0.805 20.4
0.955 24.3
1.085 27.6
1.215 30.9
1.310 33.3
1.410 35.8
1.525 38.7
1.650 41.9
1.865 47.4
1.985 50.4
2.095 53.2
2.195 55.8
2.385 60.6
2.920 74.2
3.255 82.7

115 171
147 219
200 298
320 476
440 655
623 927
936 1393
1158 1732
1394 2074
1694 2521
2066 3074
2528 3762
3070 4568
3597 5352
4124 6137
4649 6918
5680 8452
8586 12776
11185 16643

171 254
209 311
270 402
413 615
543 808
746 1110
1076 1601
1316 1958
1564 2327
1878 2794
2265 3370
2743 4082
3314 4931
3857 5739
4398 6544
4937 7346
5993 8918
8969 13346
11613 17280

*NOTE: For aluminum armored versions, add an A (ex. 036299A). For bronze armored versions, add a B (ex. 036299B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-04

Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX POWER CABLE


two conductor / LSZH / unarmored & armored
14 AWG to 1000 MCM / 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applications where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-500. Thickness as
shown in tables on the reverse.

3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (covered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.

CustRef LSX-01

DUSA_LSX01_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-500

BOSTMARINE TYPE LSX POWER CABLE


two conductor / LSZH / unarmored
14 AWG to 1000 MCM / 600V
TPC
Cable Type

Part
Number

Conductor
Size

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

DLSXTPO-4
DLSXTPO-6
DLSXTPO-10
DLSXTPO-16
DLSXTPO-26
DLSXTPO-41
DLSXTPO-66
DLSXTPO-83
DLSXTPO-106
DLSXTPO-133
DLSXTPO-168
DLSXTPO-212
DLSXTPO-250
DLSXTPO-300
DLSXTPO-350
DLSXTPO-400
DLSXTPO-500
DLSXTPO-600
DLSXTPO-750
DLSXTPO-1000

036299
036300
036301
036302
036303
036304
036305
036306
036307
036308
036309
036310
036311
036312
036313
036314
036315
036316
036317
036318

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
600 304.0
750 380.0
1000 507.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/99.2
61/110.9
61/128.0

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.080 2.03
0.080 2.03
0.080 2.03

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79

0.380 9.7
0.420 10.7
0.470 11.9
0.630 16.0
0.705 17.9
0.810 20.6
0.970 24.6
1.090 27.7
1.180 30.0
1.270 32.3
1.380 35.1
1.490 37.8
1.630 41.4
1.810 46.0
1.910 48.5
2.005 50.9
2.180 55.4
2.405 61.1
2.620 66.5
2.995 76.1

81 121
98 146
138 205
234 348
280 417
448 667
682 1015
835 1242
915 1362
1222 1818
1491 2219
1805 2686
1945 2894
2385 3549
2735 4070
3080 4584
3755 5588
4530 6741
5550 8259
7390 10997

two conductor / LSZH / aluminum and bronze armored


14 AWG to 1000 MCM / 600V
TPC
Cable Type

Part
Number*

Conductor
Size

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

DLSXTPO-4
DLSXTPO-6
DLSXTPO-10
DLSXTPO-16
DLSXTPO-26
DLSXTPO-41
DLSXTPO-66
DLSXTPO-83
DLSXTPO-106
DLSXTPO-133
DLSXTPO-168
DLSXTPO-212
DLSXTPO-250
DLSXTPO-300
DLSXTPO-350
DLSXTPO-400
DLSXTPO-500
DLSXTPO-600
DLSXTPO-750
DLSXTPO-1000

036299*
036300*
036301*
036302*
036303*
036304*
036305*
036306*
036307*
036308*
036309*
036310*
036311*
036312*
036313*
036314*
036315*
036316*
036317*
036318*

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
600 304.0
750 380.0
1000 507.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/99.2
61/110.9
61/128.0

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.080 2.03
0.080 2.03
0.080 2.03

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79

0.435 11.0
0.475 12.1
0.525 13.3
0.685 17.4
0.760 19.3
0.865 22.0
1.025 26.0
1.145 29.1
1.235 31.4
1.325 33.7
1.435 36.4
1.545 39.2
1.685 42.3
1.865 47.4
1.965 49.9
2.060 52.3
2.235 56.8
2.460 62.5
2.675 67.9
3.055 77.6

104 155
124 185
167 248
272 405
322 479
496 738
739 1100
899 1338
984 1464
1296 1928
1572 2339
1892 2815
2040 3036
2490 3705
2846 4235
3197 4757
3882 5776
4670 6949
5702 8485
7563 11254

159 237
183 272
233 347
359 534
419 623
607 903
872 1298
1047 1558
1145 1704
1469 2632
1758 2616
2093 3114
2260 3363
2734 4068
3103 4617
3466 5157
4174 6211
4992 7428
6053 9007
7964 11850

*NOTE: For aluminum armored versions, add an A (ex. 036299A). For bronze armored versions, add a B (ex. 036299B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-02

Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX SIGNAL CABLE


indiv. and overall STP / LSZH / unarmored & armored
16 AWG 1.31 mm2 / 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applications where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness as
shown in tables on the reverse.

3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (covered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.

CustRef LSX-13

DUSA_LSX13_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-512

BOSTMARINE TYPE LSX SIGNAL CABLE


indiv. and overall STP / LSZH / unarmored
16 AWG 1.31 mm2 / 600V
TPC
Cable Type

Part
Number

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP16(IS)LSXTPO-1
TP16(IS-OS)LSXTPO-2
TP16(IS-OS)LSXTPO-3
TP16(IS-OS)LSXTPO-4
TP16(IS-OS)LSXTPO-5
TP16(IS-OS)LSXTPO-6
TP16(IS-OS)LSXTPO-7
TP16(IS-OS)LSXTPO-8
TP16(IS-OS)LSXTPO-9
TP16(IS-OS)LSXTPO-10
TP16(IS-OS)LSXTPO-11
TP16(IS-OS)LSXTPO-12
TP16(IS-OS)LSXTPO-13
TP16(IS-OS)LSXTPO-14
TP16(IS-OS)LSXTPO-15
TP16(IS-OS)LSXTPO-16
TP16(IS-OS)LSXTPO-17
TP16(IS-OS)LSXTPO-18
TP16(IS-OS)LSXTPO-19
TP16(IS-OS)LSXTPO-20
TP16(IS-OS)LSXTPO-21
TP16(IS-OS)LSXTPO-22

036435
036436
036437
036438
036439
036440
036441
036442
036443
036444
036445
036446
036447
036448
036449
036450
036451
036452
036453
036454
036455
036456

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.32 8.1
0.50 12.7
0.56 14.2
0.61 15.5
0.67 17.0
0.73 18.5
0.73 18.5
0.79 20.1
0.89 22.6
0.97 24.6
0.99 25.1
0.99 25.1
1.04 26.4
1.04 26.4
1.10 27.9
1.10 27.9
1.15 29.2
1.15 29.2
1.15 29.2
1.21 30.7
1.21 30.7
1.28 32.5

56 83
104 155
153 228
190 283
227 338
265 394
295 439
332 494
370 551
449 668
487 724
516 768
555 826
585 870
621 924
654 974
694 1033
724 1078
754 1122
790 1176
824 1226
865 1287

indiv. and overall STP / LSZH / aluminum and bronze armored


16 AWG 1.31 mm2 / 600V
TPC
Cable Type

Part
Number*

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

TP16(IS)LSXTPO-1
TP16(IS-OS)LSXTPO-2
TP16(IS-OS)LSXTPO-3
TP16(IS-OS)LSXTPO-4
TP16(IS-OS)LSXTPO-5
TP16(IS-OS)LSXTPO-6
TP16(IS-OS)LSXTPO-7
TP16(IS-OS)LSXTPO-8
TP16(IS-OS)LSXTPO-9
TP16(IS-OS)LSXTPO-10
TP16(IS-OS)LSXTPO-11
TP16(IS-OS)LSXTPO-12
TP16(IS-OS)LSXTPO-13
TP16(IS-OS)LSXTPO-14
TP16(IS-OS)LSXTPO-15
TP16(IS-OS)LSXTPO-16
TP16(IS-OS)LSXTPO-17
TP16(IS-OS)LSXTPO-18
TP16(IS-OS)LSXTPO-19
TP16(IS-OS)LSXTPO-20
TP16(IS-OS)LSXTPO-21
TP16(IS-OS)LSXTPO-22

036435*
036436*
036437*
036438*
036439*
036440*
036441*
036442*
036443*
036444*
036445*
036446*
036447*
036448*
036449*
036450*
036451*
036452*
036453*
036454*
036455*
036456*

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.375 9.5
0.555 14.1
0.615 15.6
0.665 16.9
0.725 18.4
0.785 19.9
0.785 19.9
0.845 21.4
0.945 24.0
1.025 26.0
1.045 26.5
1.045 26.5
1.095 27.8
1.095 27.8
1.155 29.3
1.155 29.3
1.205 24.2
1.205 24.2
1.205 24.2
1.265 32.1
1.265 32.1
1.335 33.9

76 113
134 199
187 278
227 338
267 397
309 460
339 504
379 564
423 629
506 753
545 811
574 854
616 917
646 961
686 1021
719 1070
762 1134
792 1178
822 1123
861 1281
895 1332
940 1399

122 182
204 304
265 394
311 463
360 534
409 609
439 653
487 725
544 809
639 951
680 1012
709 1055
758 1128
788 1173
835 1242
868 1292
918 1366
948 1411
978 1455
1025 1525
1059 1576
1113 1656

*NOTE: For aluminum armored versions, add an A (ex. 036435A). For bronze armored versions, add a B (ex. 036435B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.
Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-14

10

Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX SIGNAL CABLE


indiv. and overall STP signal / LSZH / unarmored & armored
18 AWG 0.82 mm2 / 600V
APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applications where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness as
shown in tables on the reverse.

3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (covered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.

CustRef LSX-11

11

DUSA_LSX11_0905

DRAKA MOG BOSTMARINE

Manufactured to BIW Specifying Standard J512

BOSTMARINE TYPE LSX SIGNAL CABLE


indiv. and overall STP signal / LSZH / unarmored
18 AWG 0.82 mm2 / 600V
TPC
Cable Type

Part
Number

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP18(IS)LSXTPO-1
TP18(IS-OS)LSXTPO-2
TP18(IS-OS)LSXTPO-3
TP18(IS-OS)LSXTPO-4
TP18(IS-OS)LSXTPO-5
TP18(IS-OS)LSXTPO-6
TP18(IS-OS)LSXTPO-7
TP18(IS-OS)LSXTPO-8
TP18(IS-OS)LSXTPO-9
TP18(IS-OS)LSXTPO-10
TP18(IS-OS)LSXTPO-11
TP18(IS-OS)LSXTPO-12
TP18(IS-OS)LSXTPO-13
TP18(IS-OS)LSXTPO-14
TP18(IS-OS)LSXTPO-15
TP18(IS-OS)LSXTPO-16
TP18(IS-OS)LSXTPO-17
TP18(IS-OS)LSXTPO-18
TP18(IS-OS)LSXTPO-19
TP18(IS-OS)LSXTPO-20
TP18(IS-OS)LSXTPO-21
TP18(IS-OS)LSXTPO-22

036413
036414
036415
036416
036417
036418
036419
036420
036421
036422
036423
036424
036425
036426
036427
036428
036429
036430
036431
036432
036433
036434

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.30 7.6
0.45 11.4
0.48 12.2
0.59 15.0
0.61 15.5
0.66 16.8
0.66 16.8
0.72 18.3
0.78 19.8
0.89 22.6
0.91 23.1
0.91 23.1
0.96 24.4
0.96 24.4
1.01 25.7
1.01 25.7
1.06 26.9
1.06 26.9
1.06 26.9
1.11 28.2
1.11 28.2
1.16 29.5

46 68
85 126
109 162
153 228
182 271
211 314
232 346
262 390
290 432
359 534
346 516
368 548
438 652
459 684
490 729
512 762
543 808
565 840
586 872
619 921
639 951
671 998

indiv. and overall STP signal / LSZH / aluminum and bronze armored
18 AWG 0.82 mm2 / 600V
TPC
Cable Type

Part
Number*

TP18(IS)LSXTPO-1
TP18(IS-OS)LSXTPO-2
TP18(IS-OS)LSXTPO-3
TP18(IS-OS)LSXTPO-4
TP18(IS-OS)LSXTPO-5
TP18(IS-OS)LSXTPO-6
TP18(IS-OS)LSXTPO-7
TP18(IS-OS)LSXTPO-8
TP18(IS-OS)LSXTPO-9
TP18(IS-OS)LSXTPO-10
TP18(IS-OS)LSXTPO-11
TP18(IS-OS)LSXTPO-12
TP18(IS-OS)LSXTPO-13
TP18(IS-OS)LSXTPO-14
TP18(IS-OS)LSXTPO-15
TP18(IS-OS)LSXTPO-16
TP18(IS-OS)LSXTPO-17
TP18(IS-OS)LSXTPO-18
TP18(IS-OS)LSXTPO-19
TP18(IS-OS)LSXTPO-20
TP18(IS-OS)LSXTPO-21
TP18(IS-OS)LSXTPO-22

036413*
036414*
036415*
036416*
036417*
036418*
036419*
036420*
036421*
036422*
036423*
036424*
036425*
036426*
036427*
036428*
036429*
036430*
036431*
036432*
036433*
036434*

Number of Stranding
Pairs
Type
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.355 9.0
0.455 11.6
0.535 13.6
0.645 16.4
0.665 16.9
0.715 18.2
0.715 18.2
0.775 19.7
0.835 21.2
0.945 24.0
0.965 24.5
0.965 24.5
1.015 25.8
1.015 25.8
1.065 27.1
1.065 27.1
1.115 28.3
1.115 28.3
1.115 28.3
1.165 29.6
1.165 29.6
1.215 30.9

65 97
112 167
138 205
188 280
219 326
251 373
272 405
305 454
336 500
400 595
412 613
422 628
495 737
516 768
550 818
572 851
605 900
627 933
648 964
684 1018
704 1048
739 1100

108 161
176 262
206 307
271 403
303 451
342 509
363 540
404 601
444 661
524 780
533 793
546 812
626 931
647 963
687 1022
709 1055
750 1116
772 1149
793 1180
835 1242
855 1272
897 1335

*NOTE: For aluminum armored versions, add an A (ex. 036391A). For bronze armored versions, add a B (ex. 036391B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.
Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-12

12

Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX SIGNAL CABLE


indiv. and overall STP signal / LSZH / unarmored & armored
20 AWG 0.52 mm2 / 300V
APPLICATIONS
BOSTMARINE Type LSX 300 volt cables are suitable for use in commercial marine applications where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 300
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness as
shown in tables on the reverse.

3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (covered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.

CustRef LSX-09

13

DUSA_LSX09_1005

DRAKA MOG BOSTMARINE

Manufactured to BIW Specifying Standard J512

BOSTMARINE TYPE LSX SIGNAL CABLE


indiv. and overall STP signal / LSZH / unarmored
20 AWG 0.52 mm2 / 300V
TPC
Cable Type

Part
Number

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP20(IS)LSXTPO-1
TP20(IS-OS)LSXTPO-2
TP20(IS-OS)LSXTPO-3
TP20(IS-OS)LSXTPO-4
TP20(IS-OS)LSXTPO-5
TP20(IS-OS)LSXTPO-6
TP20(IS-OS)LSXTPO-7
TP20(IS-OS)LSXTPO-8
TP20(IS-OS)LSXTPO-9
TP20(IS-OS)LSXTPO-10
TP20(IS-OS)LSXTPO-11
TP20(IS-OS)LSXTPO-12
TP20(IS-OS)LSXTPO-13
TP20(IS-OS)LSXTPO-14
TP20(IS-OS)LSXTPO-15
TP20(IS-OS)LSXTPO-16
TP20(IS-OS)LSXTPO-17
TP20(IS-OS)LSXTPO-18
TP20(IS-OS)LSXTPO-19
TP20(IS-OS)LSXTPO-20
TP20(IS-OS)LSXTPO-21
TP20(IS-OS)LSXTPO-22

036391
036392
036393
036394
036395
036396
036397
036398
036399
036400
036401
036402
036403
036404
036405
036406
036407
036408
036409
036410
036411
036412

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.28 7.1
0.41 10.4
0.43 10.9
0.48 12.2
0.55 14.0
0.60 15.2
0.60 15.2
0.65 16.5
0.69 17.5
0.75 19.1
0.78 19.8
0.78 19.8
0.82 20.8
0.82 20.8
0.90 22.9
0.90 22.9
0.95 24.1
0.95 24.1
0.95 24.1
0.99 25.1
0.99 25.1
1.04 26.4

36 54
64 95
80 119
97 144
132 196
152 226
164 244
185 275
204 303
226 336
242 360
256 381
275 409
289 430
346 515
359 534
381 566
395 587
408 608
429 638
444 661
466 694

indiv. and overall STP signal / LSZH / aluminum and bronze armored
20 AWG 0.52 mm2 / 300V
TPC
Cable Type

Part
Number*

TP20(IS)LSXTPO-1
TP20(IS-OS)LSXTPO-2
TP20(IS-OS)LSXTPO-3
TP20(IS-OS)LSXTPO-4
TP20(IS-OS)LSXTPO-5
TP20(IS-OS)LSXTPO-6
TP20(IS-OS)LSXTPO-7
TP20(IS-OS)LSXTPO-8
TP20(IS-OS)LSXTPO-9
TP20(IS-OS)LSXTPO-10
TP20(IS-OS)LSXTPO-11
TP20(IS-OS)LSXTPO-12
TP20(IS-OS)LSXTPO-13
TP20(IS-OS)LSXTPO-14
TP20(IS-OS)LSXTPO-15
TP20(IS-OS)LSXTPO-16
TP20(IS-OS)LSXTPO-17
TP20(IS-OS)LSXTPO-18
TP20(IS-OS)LSXTPO-19
TP20(IS-OS)LSXTPO-20
TP20(IS-OS)LSXTPO-21
TP20(IS-OS)LSXTPO-22

036391*
036392*
036393*
036394*
036395*
036396*
036397*
036398*
036399*
036400*
036401*
036402*
036403*
036404*
036405*
036406*
036407*
036408*
036409*
036410*
036411*
036412*

Number of Stranding
Pairs
Type
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.335 8.5
0.465 11.8
0.485 12.3
0.535 13.6
0.605 15.4
0.655 16.6
0.655 16.6
0.705 17.9
0.745 18.9
0.805 20.4
0.835 21.2
0.835 21.2
0.875 22.2
0.875 22.2
0.955 24.3
0.955 24.3
1.005 25.5
1.005 25.5
1.005 25.5
1.045 26.5
1.045 26.5
1.095 27.8

54 80
89 132
106 158
126 187
165 246
188 280
200 298
224 333
245 365
271 403
288 429
302 449
324 482
338 503
399 594
412 613
437 650
451 671
464 690
487 725
502 747
527 784

95 141
147 219
167 248
194 289
242 360
271 403
283 421
314 467
340 506
374 556
396 589
410 610
436 649
450 670
522 777
535 796
567 844
581 869
594 884
622 926
637 948
669 995

*NOTE: For aluminum armored versions, add an A (ex. 036391A). For bronze armored versions, add a B (ex. 036391B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.
Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-10

14

Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N CONTROL CABLE


multi-conductor / unarmored & armored
18, 16 and 14 AWG / 600V
APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.

3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.

CustRef TN-07

15

DUSA_TN07_0905

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-500

BOSTMARINE TYPE T/N CONTROL CABLE


multi-conductor / unarmored & armored
18, 16 and 14 AWG / 600V
18 AWG 1.0 mm2
TPC
Cable Type

Part
Number of
Number* Conductors

C18T/NT-2
C18T/NT-3
C18T/NT-4
C18T/NT-7
C18T/NT-10
C18T/NT-16
C18T/NT-20
C18T/NT-24
C18T/NT-30
C18T/NT-37
C18T/NT-44
C18T/NT-61

036125*
036126*
036127*
029781*
030630*
350376
350377
036131*
036132*
036133*
036134*
036135*

2
3
4
7
10
16
20
24
30
37
44
61

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2

0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2

0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2

0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.015 / 0.004
0.015 / 0.004
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

Cable Diameter Cable Weight


Armored Cable
(nom)
(approx)
Diameter (nom)
in mm Lbs/mft Kg/km
in mm
0.28 7.1
0.29 7.4
0.31 7.9
0.36 9.1
0.45 11.4
0.57 14.5
0.63 16.0
0.65 16.5
0.69 17.5
0.74 18.8
0.86 21.8
0.95 24.1

35 52
44 65
53 79
86 128
117 174
210 312
255 379
262 390
310 461
372 554
471 701
612 911

0.33 8.4
0.34 8.6
0.36 9.1
0.41 10.4
0.50 12.7
0.63 16.0
0.69 17.5
0.70 17.8
0.74 18.8
0.79 20.1
0.91 23.1
1.00 25.4

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
53 79
62 92
72 107
108 160
144 214
244 363
292 434
301 448
351 522
416 619
522 777
668 994

94 140
105 156
117 174
160 238
208 310
324 482
379 564
391 582
446 664
518 771
640 952
798 1187

16 AWG 1.3 mm2


TPC
Cable Type

Part
Number of
Number* Conductors

C16T/NT-2
C16T/NT-3
C16T/NT-4
C16T/NT-7
C16T/NT-10
C16T/NT-16
C16T/NT-20
C16T/NT-24
C16T/NT-30
C16T/NT-37
C16T/NT-44
C16T/NT-61

030109*
036115*
030131*
030631*
030137*
350097
350101
030149*
030150*
030132*
030180*
036140*

2
3
4
7
10
16
20
24
30
37
44
61

Cable Diameter Cable Weight


Armored Cable
(nom)
(approx)
Diameter (nom)
in mm Lbs/mft Kg/km
in mm
0.30 7.6
0.31 7.9
0.34 8.6
0.39 9.9
0.50 12.7
0.63 16.0
0.69 17.5
0.72 18.3
0.77 19.6
0.87 22.1
0.96 24.4
1.07 27.2

49 73
53 79
72 107
114 170
159 237
273 406
334 497
358 533
431 641
556 827
652 970
816 1214

0.35 8.9
0.36 9.1
0.39 9.9
0.44 11.2
0.55 14.0
0.69 17.5
0.75 19.1
0.77 19.6
0.82 20.8
0.92 23.4
1.01 25.7
1.12 28.7

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
68 101
72 107
93 138
138 205
189 281
310 461
375 558
401 597
477 710
608 905
709 1055
879 1308

111 165
117 174
142 211
194 289
259 385
397 591
470 699
500 744
583 868
727 1082
840 1250
1025 1525

14 AWG 2.1 mm2


TPC
Cable Type

Part
Number of
Number* Conductors

C14T/NT-2
C14T/NT-3
C14T/NT-4
C14T/NT-7
C14T/NT-10
C14T/NT-16
C14T/NT-20
C14T/NT-24
C14T/NT-30
C14T/NT-37
C14T/NT-44
C14T/NT-61

036141*
036142*
036143*
030129*
030108*
350105
350111
030151*
036147*
030153*
036148*
036149*

2
3
4
7
10
16
20
24
30
37
44
61

Cable Diameter Cable Weight


Armored Cable
(nom)
(approx)
Diameter (nom)
in mm Lbs/mft Kg/km
in mm
0.33 8.4
0.35 8.9
0.37 9.4
0.44 11.2
0.58 14.7
0.69 17.5
0.74 18.8
0.81 20.6
0.90 22.9
0.96 24.4
1.08 27.4
1.14 29.0

62 92
81 121
101 150
157 234
240 357
366 545
451 671
494 735
639 951
762 1134
901 1341
1210 1801

0.38 9.7
0.40 10.2
0.42 10.7
0.49 12.4
0.63 16.0
0.75 19.1
0.80 20.3
0.86 21.8
0.95 24.1
1.01 25.7
1.13 28.7
1.19 30.2

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
83 124
103 153
124 185
184 274
275 409
407 606
495 737
542 806
692 1030
818 1217
965 1436
1277 1900

130 193
153 228
177 263
246 366
356 530
502 747
596 887
653 972
815 1213
950 1414
1112 1655
1432 2131

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-08

16

Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N CONTROL CABLE


multi-conductor shielded / unarmored & armored
16 and 14 AWG / 600V
APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.

3. SHIELD
An aluminum/polyester tape with drain wire, 100% coverage, is applied over the
cabled core.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.

CustRef TN-19

17

DUSA_TN19_0905

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-500

BOSTMARINE TYPE T/N CONTROL CABLE


multi-conductor shielded / unarmored & armored
16 and 14 AWG / 600V
16 AWG 1.3 mm2
TPC
Cable Type

Part
Number of
Number* Conductors

C16(OS)T/NT-2
C16(OS)T/NT-3
C16(OS)T/NT-4
C16(OS)T/NT-7
C16(OS)T/NT-10
C16(OS)T/NT-16
C16(OS)T/NT-20
C16(OS)T/NT-24
C16(OS)T/NT-30
C16(OS)T/NT-37
C16(OS)T/NT-44
C16(OS)T/NT-61

030109*
036115*
030131*
030631*
030137*
350172*
350166*
030149*
030150*
030132*
030180*
036140*

2
3
4
7
10
16
20
24
30
37
44
61

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2

0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2

0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48
0.019 0.48

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

Cable Diameter Cable Weight Armored Cable Aluminum arm.


Bronze arm.
(nom)
(approx)
Diameter (nom)
Cable Weight
Cable Weight
in mm Lbs/mft Kg/km
in mm
Lbs/mft Kg/km Lbs/mft Kg/km
0.31 7.9
0.33 8.4
0.35 8.9
0.42 10.7
0.55 14.0
0.63 16.0
0.70 17.8
0.76 19.3
0.81 20.6
0.91 23.1
1.03 26.2
1.13 28.7

58 86
63 94
82 122
124 185
169 251
281 418
343 510
371 552
444 661
569 847
666 991
830 1235

0.37 9.4
0.39 9.9
0.41 10.4
0.48 12.2
0.58 14.7
0.69 17.5
0.76 19.3
0.82 20.8
0.87 22.1
0.97 24.6
1.09 27.7
1.19 30.2

77 115
83 124
103 153
150 305
200 418
319 475
385 573
416 619
492 1056
623 927
727 1082
896 1333

122 182
130 193
153 228
209 311
273 406
406 604
480 714
521 775
602 896
747 1112
867 1290
1049 1561

14 AWG 2.1 mm2


TPC
Cable Type

Part
Number of
Number* Conductors

C14(OS)T/NT-2
C14(OS)T/NT-3
C14(OS)T/NT-4
C14(OS)T/NT-7
C14(OS)T/NT-10
C14(OS)T/NT-16
C14(OS)T/NT-20
C14(OS)T/NT-24
C14(OS)T/NT-30
C14(OS)T/NT-37
C14(OS)T/NT-44
C14(OS)T/NT-61

036141*
036142*
036143*
030129*
030108*
350374*
350375*
030151*
036147*
030153*
036148*
036149*

2
3
4
7
10
16
20
24
30
37
44
61

Cable Diameter Cable Weight Armored Cable Aluminum arm.


Bronze arm.
(nom)
(approx)
Diameter (nom)
Cable Weight
Cable Weight
in mm Lbs/mft Kg/km
in mm
Lbs/mft Kg/km Lbs/mft Kg/km
0.34 8.6
0.36 9.1
0.42 10.7
0.46 11.6
0.58 14.7
0.63 16.0
0.71 18.0
0.84 21.3
0.93 23.6
1.00 25.4
1.13 28.7
1.18 30.0

75 112
94 140
115 171
171 254
254 377
378 562
462 687
510 759
655 975
778 1158
917 1364
1226 1824

0.40 10.2
0.42 10.7
0.48 12.2
0.52 13.2
0.64 16.3
0.75 19.1
0.82 20.8
0.90 22.9
0.99 25.1
1.06 26.9
1.19 30.2
1.24 31.5

96 143
116 173
140 208
199 296
206 307
419 623
507 754
560 833
710 1056
837 1245
983 1463
1295 1927

145 216
167 248
219 326
273 406
369 549
514 765
612 911
675 1004
837 1245
972 1446
1137 1692
1456 2167

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-20

18

Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N CONTROL CABLE


indiv. & overall shielded triads / unarmored & armored
18, 16 and 14 AWG / 600V
DRAKA-USA

APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

ISO9001
QSC3497

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.
3. TRIAD SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.

4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.

CustRef TN-17

19

DUSA_TN17_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-510

BOSTMARINE TYPE T/N CONTROL CABLE


indiv. & overall shielded twisted triad / unarmored & armored
18, 16 and 14 AWG / 600V
18 AWG 1.0 mm2
Insulation
TPC
Part
Number of Stranding Thickness
Cable Type
Number*
triads
Type
in mm
TT18(IS-OS)T/NT-1 350370
1
7/15.2 0.019 0.48
TT18(IS-OS)T/NT-3 350371
3
7/15.2 0.019 0.48
TT18(IS-OS)T/NT-6 350372
6
7/15.2 0.019 0.48
TT18(IS-OS)T/NT-12350373
12
7/15.2 0.019 0.48

Jacket Cable Diameter Cable Weight


Armored Cable
Thickness
(nom)
(approx)
Diameter (nom)
in mm
in mm Lbs/mft Kg/km
in mm
0.045 1.14 0.31 7.9
56 83
0.37 9.4
0.060 1.52 0.59 15.0
174 259
0.65 16.5
0.060 1.52 0.76 19.3
294 437
0.82 20.8
0.080 2.03 1.05 26.7
567 844
1.11 28.2

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
75 112
119 177
209 311
291 433
339 504
444 661
629 936
772 1149

Jacket Cable Diameter Cable Weight


Armored Cable
Thickness
(nom)
(approx)
Diameter (nom)
in mm
in mm Lbs/mft Kg/km
in mm
0.045 1.14 0.33 8.4
70 104
0.39 9.9
0.060 1.52 0.64 16.3
222 330
0.70 17.8
0.060 1.52 0.84 21.3
380 565
0.90 22.9
0.080 2.03 1.15 29.2
683 1016
1.21 30.7

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
91 135
138 205
260 387
349 519
430 640
555 826
751 1117
907 1350

Jacket Cable Diameter Cable Weight


Armored Cable
Thickness
(nom)
(approx)
Diameter (nom)
in mm
in mm Lbs/mft Kg/km
in mm
0.045 1.14 0.36 9.1
93 138
0.42 10.7
0.060 1.52 0.70 17.8
294 437
0.76 19.3
0.060 1.52 0.96 24.4
558 830
1.02 25.9
0.080 2.03 1.26 32.0
1007 1498
1.32 33.5

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
115 171
166 247
336 500
431 641
614 914
745 1109
1081 1609
1251 1861

16 AWG 1.3 mm2


Insulation
TPC
Part
Number of Stranding Thickness
Cable Type
Number*
triads
Type
in mm
TT16(IS-OS)T/NT-1 350366
1
7/19.2 0.019 0.48
TT16(IS-OS)T/NT-3 350367
3
7/19.2 0.019 0.48
TT16(IS-OS)T/NT-6 350368
6
7/19.2 0.019 0.48
TT16(IS-OS)T/NT-12350369
12
7/19.2 0.019 0.48

14 AWG 2.1 mm2


Insulation
TPC
Part
Number of Stranding Thickness
Cable Type
Number*
triads
Type
in mm
TT14(IS-OS)T/NT-1 350362
1
7/24.2 0.019 0.48
TT14(IS-OS)T/NT-3 350363
3
7/24.2 0.019 0.48
TT14(IS-OS)T/NT-6 350364
6
7/24.2 0.019 0.48
TT14(IS-OS)T/NT-12350365
12
7/24.2 0.019 0.48

*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-18

20

Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N POWER CABLE


four conductor power distribution / unarmored & armored
14 AWG to 750 MCM / 600V
APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated Vw1.

3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.

CustRef TN-05

21

DUSA_TN05_0905

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-500

BOSTMARINE TYPE T/N POWER CABLE


four conductor power distribution / unarmored
14 AWG to 750 MCM / 600V
TPC
Cable Type

Part
Number

Conductor Size
AWG/MCM mm2

Stranding
Type

PVC/Nylon
Insulation Thickness
in mm

Jacket
Thickness
in mm

Unarmored
Cable Diameter
in mm

Unarmored
Cable Weight
Lbs/mft Kg/km

FT/NT-4
FT/NT-6
FT/NT-10
FT/NT-16
FT/NT-26
FT/NT-41
FT/NT-66
FT/NT-83
FT/NT-106
FT/NT-133
FT/NT-168
FT/NT-212
FT/NT-250
FT/NT-300
FT/NT-350
FT/NT-400
FT/NT-500
FT/NT-600
FT/NT-750

030104
030130
030128
030135
030134
030133
030179
036114
036115
036116
036117
030177
036118
036119
036120
036121
036122
036123
036124

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
600 304.0
750 380.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/99.2
61/110.9

0.015/0.38 0.004/0.10
0.015/0.38 0.004/0.10
0.020/0.51 0.004/0.10
0.030/0.76 0.005//0.13
0.030/0.76 0.005/0.13
0.040/1.02 0.006/0.15
0.040//1.02 0.006/0.15
0.050/1.27 0.007/0.18
0.050/1.27 0.007/0.18
0.050/1.27 0.007/0.18
0.050/1.27 0.007/0.18
0.050/1.27 0.007/0.18
0.060/1.52 0.008/0.20
0.060/1.52 0.008/0.20
0.060/1.52 0.008/0.20
0.060/1.52 0.008/0.20
0.060/1.52 0.008/0.20
0.070/1.78 0.009/0.23
0.070/1.78 0.009/0.23

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.140 3.56
0.140 3.56

0.39 9.9
0.43 10.9
0.51 13.0
0.66 16.8
0.77 19.6
0.99 25.1
1.13 28.7
1.27 32.3
1.38 35.1
1.49 37.8
1.61 40.9
1.82 46.2
1.98 50.3
2.11 53.6
2.34 59.4
2.46 62.5
2.56 65.0
2.87 72.9
3.11 79.0

151 225
225 335
366 545
536 798
878 1307
1268 1887
1598 2378
1924 2863
2374 3533
2569 3823
2850 4241
3650 5432
4319 6427
5051 7517
5866 8730
6623 9856
8086 12033
9657 14371
11949 17782

four conductor power distribution / aluminum or bronze armored


14 AWG to 750 MCM / 600V
TPC
Cable Type

Part
Number*

Conductor Size
AWG/MCM mm2

Stranding
Type

PVC/Nylon
Insulation Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

FT/NT-4
FT/NT-6
FT/NT-10
FT/NT-16
FT/NT-26
FT/NT-41
FT/NT-66
FT/NT-83
FT/NT-106
FT/NT-133
FT/NT-168
FT/NT-212
FT/NT-250
FT/NT-300
FT/NT-350
FT/NT-400
FT/NT-500
FT/NT-600
FT/NT-750

030104*
030130*
030128*
030135*
030134*
030133*
030179*
036114*
036115*
036116*
036117*
030177*
036118*
036119*
036120*
036121*
036122*
036123*
036124*

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
600 304.0
750 380.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/99.2
61/110.9

0.015/0.38 0.004/0.10
0.015/0.38 0.004/0.10
0.020/0.51 0.004/0.10
0.030/0.76 0.005//0.13
0.030/0.76 0.005/0.13
0.040/1.02 0.006/0.15
0.040//1.02 0.006/0.15
0.050/1.27 0.007/0.18
0.050/1.27 0.007/0.18
0.050/1.27 0.007/0.18
0.050/1.27 0.007/0.18
0.050/1.27 0.007/0.18
0.060/1.52 0.008/0.20
0.060/1.52 0.008/0.20
0.060/1.52 0.008/0.20
0.060/1.52 0.008/0.20
0.060/1.52 0.008/0.20
0.070/1.78 0.009/0.23
0.070/1.78 0.009/0.23

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.140 3.56
0.140 3.56

0.44 11.2
0.48 12.2
0.56 14.2
0.71 18.1
0.82 20.9
1.04 26.4
1.18 30.0
1.32 33.8
1.43 36.3
1.54 39.1
1.66 42.2
1.87 47.5
2.03 51.6
2.16 54.9
2.39 60.7
2.51 63.8
2.61 66.3
2.92 74.2
3.16 80.3

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
174 259
251 373
396 589
575 856
923 1373
1325 1971
1663 2475
1997 2972
2453 3650
2654 3949
2942 4378
3753 5584
4431 6593
5171 7694
5999 8927
6762 10062
8235 12254
9819 14611
12125 18042

229 341
310 461
466 693
664 988
1026 1527
1457 2168
1813 2698
2165 3222
2635 3921
2850 4241
3154 4693
3993 5942
4691 6980
5447 8105
6305 9382
7084 10541
8566 12746
10194 15169
12531 18646

*NOTE: For aluminum armored versions, add an A (ex. 030104A). For bronze armored versions, add a B (ex. 030104B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-06

22

Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N POWER CABLE


three conductor power distribution / unarmored & armored
14 AWG to 750 MCM / 600V
APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.

3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.

CustRef TN-03

23

DUSA_TN03_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-500

BOSTMARINE TYPE T/N POWER CABLE


three conductor power distribution / unarmored & armored
14 AWG to 750 MCM / 600V
TPC
Cable Type

Part
Number

Conductor Size
AWG/MCM mm2

Stranding
Type

PVC/Nylon
Insulation Thickness
in mm

Jacket
Thickness
in mm

Unarmored
Cable Diameter
in mm

Unarmored
Cable Weight
Lbs/mft Kg/km

TT/NT-4
TT/NT-6
TT/NT-10
TT/NT-16
TT/NT-26
TT/NT-41
TT/NT-66
TT/NT-83
TT/NT-106
TT/NT-133
TT/NT-168
TT/NT-212
TT/NT-250
TT/NT-300
TT/NT-350
TT/NT-400
TT/NT-500
TT/NT-600
TT/NT-750

030101
030102
030107
030106
030105
030110
030112
036102
030178
036103
036104
036105
036106
036107
036108
036109
036110
036111
036112

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
600 304.0
750 380.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/99.2
61/110.9

0.015/0.004 0.38/0.10
0.015/0.004 0.38/0.10
0.020/0.004 0.51/0.10
0.030/0.005 0.76/0.13
0.030/0.005 0.76/0.13
0.040/0.006 1.02/0.15
0.040/0.006 1.02/0.15
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.060/0.008 1.52/0.20
0.060/0.008 1.52/0.20
0.060/0.008 1.52/0.20
0.060/0.008 1.52/0.20
0.060/0.008 1.52/0.20
0.070/0.009 1.78/0.22
0.070/0.009 1.78/0.22

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79

0.35 8.9
0.39 9.9
0.46 11.7
0.61 15.5
0.69 17.5
0.84 21.3
1.02 25.9
1.16 29.5
1.24 31.5
1.36 34.5
1.45 36.8
1.59 40.4
1.80 45.7
1.91 48.5
2.05 52.1
2.22 56.4
2.45 62.2
2.52 64.0
2.83 71.9

86 128
120 179
171 254
301 448
406 604
664 988
980 1458
1228 1827
1557 2317
1828 2720
2244 3339
2773 4127
3360 5000
3920 5834
4550 6771
5133 7639
6472 9631
7375 10975
9200 13691

three conductor power distribution / aluminum or bronze armored


14 AWG to 750 MCM / 600V
TPC
Cable Type

Part
Number*

Conductor Size
AWG/MCM mm2

Stranding
Type

PVC/Nylon
Insulation Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

TT/NT-4
TT/NT-6
TT/NT-10
TT/NT-16
TT/NT-26
TT/NT-41
TT/NT-66
TT/NT-83
TT/NT-106
TT/NT-133
TT/NT-168
TT/NT-212
TT/NT-250
TT/NT-300
TT/NT-350
TT/NT-400
TT/NT-500
TT/NT-600
TT/NT-750

030101*
030102*
030107*
030106*
030105*
030110*
030112*
036102*
030178*
036103*
036104*
036105*
036106*
036107*
036108*
036109*
036110*
036111*
036112*

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
600 304.0
750 380.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/99.2
61/110.9

0.015/0.004 0.38/0.10
0.015/0.004 0.38/0.10
0.020/0.004 0.51/0.10
0.030/0.005 0.76/0.13
0.030/0.005 0.76/0.13
0.040/0.006 1.02/0.15
0.040/0.006 1.02/0.15
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.060/0.008 1.52/0.20
0.060/0.008 1.52/0.20
0.060/0.008 1.52/0.20
0.060/0.008 1.52/0.20
0.060/0.008 1.52/0.20
0.070/0.009 1.78/0.22
0.070/0.009 1.78/0.22

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79

0.38 9.7
0.44 11.2
0.51 13.0
0.66 16.8
0.74 18.8
0.89 22.6
1.07 27.2
1.21 30.8
1.29 32.8
1.41 35.8
1.50 38.1
1.64 41.7
1.85 47.0
1.96 49.8
2.10 53.4
2.27 57.7
2.50 63.5
2.57 65.3
2.88 73.2

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
107 159
143 213
198 295
337 501
446 664
713 1061
1039 1626
1295 1927
1628 2422
1906 2836
2327 3463
2864 4262
3462 5151
4029 5995
4666 6943
5259 7825
6611 9837
7518 11187
9360 13928

156 232
198 295
262 390
419 623
539 802
825 1228
1174 1747
1448 2155
1792 2666
2085 3102
2518 3747
3073 4573
3699 5504
4280 6369
4935 7343
5550 8258
6932 10315
7847 11676
9730 14478

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-04

24

Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N POWER CABLE


two conductor power distribution / unarmored & armored
14 AWG to 500 MCM / 600V
APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.

3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.

CustRef TN-01

25

DUSA_TN01_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-500

BOSTMARINE TYPE T/N POWER CABLE


two conductor power distribution / unarmored & armored
14 AWG to 500 MCM / 600V
TPC
Cable Type

Part
Number

Conductor Size
AWG/MCM mm2

Stranding
Type

PVC/Nylon
Insulation Thickness
in mm

Jacket
Thickness
in mm

Unarmored
Cable Diameter
in mm

Unarmored
Cable Weight
Lbs/mft Kg/km

DT/NT-4
DT/NT-6
DT/NT-10
DT/NT-16
DT/NT-26
DT/NT-41
DT/NT-66
DT/NT-83
DT/NT-106
DT/NT-133
DT/NT-168
DT/NT-212
DT/NT-250
DT/NT-300
DT/NT-350
DT/NT-400
DT/NT-500

030103
030123
030114
030138
030139
030182
036090
036091
036092
036093
036094
036095
036096
036097
036049
036098
036099

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2

0.015/0.004 0.38/0.10
0.015/0.004 0.38/0.10
0.020/0.004 0.51/0.10
0.030/0.005 0.76/0.13
0.030/0.005 0.76/0.13
0.040/0.006 1.02/0.15
0.040/0.006 1.02/0.15
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.060/0.080 1.52/2.03
0.060/0.080 1.52/2.03
0.060/0.080 1.52/2.03
0.060/0.080 1.52/2.03
0.060/0.080 1.52/2.03

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79

0.33 8.4
0.37 9.4
0.43 10.9
0.58 14.7
0.65 16.5
0.80 20.3
0.97 24.6
1.00 25.4
1.18 30.0
1.27 32.3
1.38 35.1
1.56 39.6
1.62 41.1
1.80 45.7
1.90 48.3
2.08 52.8
2.17 55.1

66 98
88 131
133 198
216 321
311 463
479 713
727 1082
933 1388
1110 1652
1323 1969
1602 2384
2122 3158
2337 3478
2851 4243
3303 4915
3662 5450
4497 6692

two conductor power distribution / aluminum or bronze armored


14 AWG to 750 MCM / 600V
TPC
Cable Type

Part
Number*

Conductor Size
AWG/MCM mm2

Stranding
Type

PVC/Nylon
Insulation Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

DT/NT-4
DT/NT-6
DT/NT-10
DT/NT-16
DT/NT-26
DT/NT-41
DT/NT-66
DT/NT-83
DT/NT-106
DT/NT-133
DT/NT-168
DT/NT-212
DT/NT-250
DT/NT-300
DT/NT-350
DT/NT-400
DT/NT-500

030103*
030123*
030114*
030138*
030139*
030182*
036090*
036091*
036092*
036093*
036094*
036095*
036096*
036097*
036049*
036098*
036099*

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2

0.015/0.004 0.38/0.10
0.015/0.004 0.38/0.10
0.020/0.004 0.51/0.10
0.030/0.005 0.76/0.13
0.030/0.005 0.76/0.13
0.040/0.006 1.02/0.15
0.040/0.006 1.02/0.15
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.050/0.007 1.27/0.18
0.060/0.080 1.52/2.03
0.060/0.080 1.52/2.03
0.060/0.080 1.52/2.03
0.060/0.080 1.52/2.03
0.060/0.080 1.52/2.03

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79

0.38 9.7
0.42 10.7
0.48 12.5
0.63 16.0
0.70 17.8
0.85 21.6
1.02 25.9
1.05 26.7
1.23 31.3
1.32 33.6
1.43 36.3
1.61 40.9
1.67 42.4
1.85 47.0
1.95 49.6
2.13 54.1
2.22 56.4

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
86 128
110 164
159 237
250 372
351 522
530 789
791 1177
991 1475
1178 1753
1396 2077
1681 2501
2211 3290
2429 3614
2953 4394
3411 5076
3780 5625
4620 6875

132 196
162 240
218 324
329 490
437 650
633 942
912 1357
1124 1673
1334 1985
1564 2327
1863 2772
2416 3595
2643 3933
3190 4747
3660 5446
4053 6031
4904 7297

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-02

26

Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
14 AWG 2.1 mm2 / 600V
DRAKA-USA

APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

ISO9001
QSC3497

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION

1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.

3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.

CustRef TN-15

27

DUSA_TN15_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-510

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
14 AWG 2.1 mm2 / 600V
TPC
Cable Type

Part
Number

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP14(IS-OS)T/NT-1
TP14(IS-OS)T/NT-2
TP14(IS-OS)T/NT-3
TP14(IS-OS)T/NT-4
TP14(IS-OS)T/NT-6

350356
350357
350358
350360
350361

1
2
3
4
6

7/24.2
7/24.2
7/24.2
7/24.2
7/24.2

0.015 / 0.004 0.38 / 0.10


0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10

0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52

0.340 8.6
0.575 14.6
0.605 15.4
0.665 16.9
0.790 20.1

73 109
175 260
228 339
282 420
392 583

indiv. & overall shielded twisted pair / aluminum or bronze armored


14 AWG 2.1 mm2 / 600V
TPC
Cable Type

Part
Number*

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

TP14(IS-OS)T/NT-1
TP14(IS-OS)T/NT-2
TP14(IS-OS)T/NT-3
TP14(IS-OS)T/NT-4
TP14(IS-OS)T/NT-6

350356*
350357*
350358*
350360*
350361*

1
2
3
4
6

7/24.2
7/24.2
7/24.2
7/24.2
7/24.2

0.015 / 0.004 0.38 / 0.10


0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10

0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52

0.400 10.2
0.635 16.1
0.665 16.9
0.725 18.4
0.850 21.6

94 140
210 312
264 393
322 479
439 653

143 213
290 432
348 518
414 616
547 814

*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-16

28

Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
16 AWG 1.3 mm2 / 600V
DRAKA-USA

APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

ISO9001
QSC3497

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION

1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.

3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.

CustRef TN-13

29

DUSA_TN13_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-510

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
16 AWG 1.3 mm2 / 600V
TPC
Cable Type

Part
Number

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP16(IS)T/NT-1
TP16(IS-OS)T/NT-2
TP16(IS-OS)T/NT-3
TP16(IS-OS)T/NT-4
TP16(IS-OS)T/NT-5
TP16(IS-OS)T/NT-6
TP16(IS-OS)T/NT-7
TP16(IS-OS)T/NT-8
TP16(IS-OS)T/NT-9
TP16(IS-OS)T/NT-10
TP16(IS-OS)T/NT-11
TP16(IS-OS)T/NT-12
TP16(IS-OS)T/NT-13
TP16(IS-OS)T/NT-14
TP16(IS-OS)T/NT-15
TP16(IS-OS)T/NT-16
TP16(IS-OS)T/NT-17
TP16(IS-OS)T/NT-18
TP16(IS-OS)T/NT-19
TP16(IS-OS)T/NT-20
TP16(IS-OS)T/NT-21
TP16(IS-OS)T/NT-22

030160
030162
036194
030164
036196
030165
036198
030166
036200
036201
036202
036203
036204
036205
030161
036207
036208
036209
036210
030163
036212
036213

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2

0.015 / 0.004 0.38 / 0.10


0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.29 7.4
0.43 11.0
0.46 11.7
0.50 12.8
0.58 14.8
0.63 16.1
0.63 16.1
0.69 17.4
0.74 18.8
0.81 20.4
0.88 22.2
0.88 22.2
0.92 23.3
0.92 23.3
0.97 24.6
0.97 24.6
1.02 25.9
1.02 25.9
1.02 25.9
1.07 27.2
1.07 27.2
1.12 28.5

49 72
58 86
124 184
155 231
205 306
240 356
268 398
300 446
337 502
373 555
401 597
466 693
501 746
530 788
566 842
594 884
630 938
659 981
687 1023
724 1077
752 1119
789 1174

indiv. & overall shielded twisted pair / aluminum or bronze armored


16 AWG 1.3 mm2 / 600V
TPC
Cable Type

Part
Number of
Number* Pairs

TP16(IS)T/NT-1
TP16(IS-OS)T/NT-2
TP16(IS-OS)T/NT-3
TP16(IS-OS)T/NT-4
TP16(IS-OS)T/NT-5
TP16(IS-OS)T/NT-6
TP16(IS-OS)T/NT-7
TP16(IS-OS)T/NT-8
TP16(IS-OS)T/NT-9
TP16(IS-OS)T/NT-10
TP16(IS-OS)T/NT-11
TP16(IS-OS)T/NT-12
TP16(IS-OS)T/NT-13
TP16(IS-OS)T/NT-14
TP16(IS-OS)T/NT-15
TP16(IS-OS)T/NT-16
TP16(IS-OS)T/NT-17
TP16(IS-OS)T/NT-18
TP16(IS-OS)T/NT-19
TP16(IS-OS)T/NT-20
TP16(IS-OS)T/NT-21
TP16(IS-OS)T/NT-22

030160*
030162*
036194*
030164*
036196*
030165*
036198*
030166*
036200*
036201*
036202*
036203*
036204*
036205*
030161*
036207*
036208*
036209*
036210*
030163*
036212*
036213*

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2

0.015 / 0.004 0.38 / 0.10


0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.34 8.7
0.48 12.2
0.51 13.0
0.55 14.0
0.63 16.0
0.68 17.3
0.68 17.3
0.74 18.8
0.79 20.1
0.86 21.9
0.93 23.6
0.93 23.6
0.97 24.7
0.97 24.7
1.02 25.9
1.02 25.9
1.07 27.2
1.07 27.2
1.07 27.2
1.12 28.5
1.12 28.5
1.17 29.7

67 100
84 125
151 225
185 275
239 356
277 412
305 454
340 506
380 565
420 625
452 673
517 769
554 824
583 868
622 926
650 967
689 1025
718 1068
746 1110
786 1170
814 1211
853 1269

108 161
143 213
215 320
253 376
318 473
362 539
390 580
433 644
479 713
528 786
569 847
634 943
677 1007
706 1051
751 1117
779 1159
824 1226
853 1269
881 1311
928 1381
956 1423
1002 1491

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.
Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-14

30

Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
18 AWG 0.82 mm2 / 600V
DRAKA-USA

APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

ISO9001
QSC3497

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION

1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.

3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.

CustRef TN-11

31

DUSA_TN11_0905

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-510

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
18 AWG 0.82 mm2 / 600V
TPC
Cable Type

Part
Number

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP18(IS)T/NT-1
TP18(IS-OS)T/NT-2
TP18(IS-OS)T/NT-3
TP18(IS-OS)T/NT-4
TP18(IS-OS)T/NT-5
TP18(IS-OS)T/NT-6
TP18(IS-OS)T/NT-7
TP18(IS-OS)T/NT-8
TP18(IS-OS)T/NT-9
TP18(IS-OS)T/NT-10
TP18(IS-OS)T/NT-11
TP18(IS-OS)T/NT-12
TP18(IS-OS)T/NT-13
TP18(IS-OS)T/NT-14
TP18(IS-OS)T/NT-15
TP18(IS-OS)T/NT-16
TP18(IS-OS)T/NT-17
TP18(IS-OS)T/NT-18
TP18(IS-OS)T/NT-19
TP18(IS-OS)T/NT-20
TP18(IS-OS)T/NT-21
TP18(IS-OS)T/NT-22

029504
030171
029509
030173
029511
036176
029514
030174
036179
029503
036180
030170
036182
036183
036184
036185
036186
036187
036188
029507
036190
036191

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2

0.015 / 0.004 0.38 / 0.10


0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.27 6.8
0.39 10.0
0.42 10.6
0.46 11.6
0.50 12.7
0.57 14.6
0.57 14.6
0.62 15.7
0.67 16.9
0.72 18.4
0.75 19.0
0.75 19.0
0.79 20.0
0.79 20.0
0.87 22.1
0.87 22.1
0.92 23.3
0.92 23.3
0.92 23.3
0.96 24.5
0.96 24.5
1.01 25.7

40 59
74 111
97 145
122 181
147 218
189 282
210 313
237 352
263 392
291 433
312 465
336 500
361 538
383 570
442 659
464 690
492 732
513 763
534 795
562 837
584 868
613 912

indiv. & overall shielded twisted pair / aluminum or bronze armored


18 AWG 0.82 mm2 / 600V
TPC
Cable Type

Part
Number of
Number*
Pairs

TP18(IS)T/NT-1
TP18(IS-OS)T/NT-2
TP18(IS-OS)T/NT-3
TP18(IS-OS)T/NT-4
TP18(IS-OS)T/NT-5
TP18(IS-OS)T/NT-6
TP18(IS-OS)T/NT-7
TP18(IS-OS)T/NT-8
TP18(IS-OS)T/NT-9
TP18(IS-OS)T/NT-10
TP18(IS-OS)T/NT-11
TP18(IS-OS)T/NT-12
TP18(IS-OS)T/NT-13
TP18(IS-OS)T/NT-14
TP18(IS-OS)T/NT-15
TP18(IS-OS)T/NT-16
TP18(IS-OS)T/NT-17
TP18(IS-OS)T/NT-18
TP18(IS-OS)T/NT-19
TP18(IS-OS)T/NT-20
TP18(IS-OS)T/NT-21
TP18(IS-OS)T/NT-22

029504*
030171*
029509*
030173*
029511*
036176*
029514*
030174*
036179*
029503*
036180*
030170*
036182*
036183*
036184*
036185*
036186*
036187*
036188*
029507*
036190*
036191*

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2

0.015 / 0.004 0.38 / 0.10


0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.32 8.2
0.44 11.2
0.47 12.0
0.40 10.2
0.55 14.0
0.62 15.8
0.62 15.8
0.67 17.0
0.72 18.3
0.77 19.6
0.80 20.3
0.80 20.3
0.84 21.4
0.84 21.4
0.92 23.4
0.92 23.4
0.97 24.7
0.97 24.7
0.97 24.7
1.01 25.7
1.01 25.7
1.06 26.9

57 85
97 144
122 182
149 222
177 263
223 332
244 363
273 406
302 449
333 496
356 530
380 565
407 606
429 638
492 732
514 765
545 811
566 842
587 873
617 918
639 951
671 998

95 141
152 226
180 268
213 317
245 365
300 446
321 478
257 382
393 585
430 640
456 679
480 714
513 763
535 796
608 905
630 937
668 994
689 1025
710 1056
745 1109
767 1141
806 1199

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.
Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-12

32

Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
20 AWG 0.52 mm2 / 300V
DRAKA-USA

APPLICATIONS
BOSTMARINE Type T/N 300 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 300 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

ISO9001
QSC3497

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION

1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.

3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.

CustRef TN-09

33

DUSA_TN09_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-510

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored
20 AWG 0.52 mm2 / 300V
TPC
Cable Type

Part
Number

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP20(IS)T/NT-1
TP20(IS-OS)T/NT-2
TP20(IS-OS)T/NT-3
TP20(IS-OS)T/NT-4
TP20(IS-OS)T/NT-5
TP20(IS-OS)T/NT-6
TP20(IS-OS)T/NT-7
TP20(IS-OS)T/NT-8
TP20(IS-OS)T/NT-9
TP20(IS-OS)T/NT-10
TP20(IS-OS)T/NT-11
TP20(IS-OS)T/NT-12
TP20(IS-OS)T/NT-13
TP20(IS-OS)T/NT-14
TP20(IS-OS)T/NT-15
TP20(IS-OS)T/NT-16
TP20(IS-OS)T/NT-17
TP20(IS-OS)T/NT-18
TP20(IS-OS)T/NT-19
TP20(IS-OS)T/NT-20
TP20(IS-OS)T/NT-21
TP20(IS-OS)T/NT-22

030190
030193
030194
030195
036154
036155
036156
036157
036158
029501
036159
030191
036161
036162
036163
036164
036165
036166
036167
036168
036169
036170

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1

0.015 / 0.004 0.38 / 0.10


0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03

0.25 6.3
0.36 9.1
0.38 9.7
0.41 10.5
0.45 11.5
0.49 12.5
0.49 12.5
0.56 14.3
0.61 15.4
0.66 16.7
0.68 17.2
0.68 17.2
0.71 18.1
0.71 18.1
0.75 19.1
0.75 19.1
0.79 20.2
0.79 20.2
0.79 20.2
0.88 22.2
0.88 22.2
0.92 23.3

33 49
61 91
80 119
99 147
118 175
137 204
153 228
186 277
211 314
229 341
245 365
267 397
287 427
303 450
323 481
339 504
360 535
375 559
391 582
447 665
463 689
485 722

indiv. & overall shielded twisted pair / aluminum or bronze armored


20 AWG 0.52 mm2 / 300V
TPC
Cable Type

Part
Number of
Number*
Pairs

TP20(IS)T/NT-1
TP20(IS-OS)T/NT-2
TP20(IS-OS)T/NT-3
TP20(IS-OS)T/NT-4
TP20(IS-OS)T/NT-5
TP20(IS-OS)T/NT-6
TP20(IS-OS)T/NT-7
TP20(IS-OS)T/NT-8
TP20(IS-OS)T/NT-9
TP20(IS-OS)T/NT-10
TP20(IS-OS)T/NT-11
TP20(IS-OS)T/NT-12
TP20(IS-OS)T/NT-13
TP20(IS-OS)T/NT-14
TP20(IS-OS)T/NT-15
TP20(IS-OS)T/NT-16
TP20(IS-OS)T/NT-17
TP20(IS-OS)T/NT-18
TP20(IS-OS)T/NT-19
TP20(IS-OS)T/NT-20
TP20(IS-OS)T/NT-21
TP20(IS-OS)T/NT-22

030190*
030193*
030194*
030195*
036154*
036155*
036156*
036157*
036158*
029501*
036159*
030191*
036161*
036162*
036163*
036164*
036165*
036166*
036167*
036168*
036169*
036170*

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1

0.015 / 0.004 0.38 / 0.10


0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10
0.015 / 0.004 0.38 / 0.10

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03

0.30 7.6
0.41 10.4
0.43 10.9
0.46 11.7
0.50 12.7
0.54 13.7
0.54 13.7
0.61 15.5
0.66 15.4
0.71 18.0
0.73 18.5
0.73 18.5
0.76 19.3
0.76 19.3
0.80 20.3
0.80 20.3
0.84 21.3
0.84 21.3
0.84 21.3
0.93 23.6
0.93 22.2
0.97 23.3

49 73
83 135
103 153
124 185
145 216
167 248
183 272
220 327
248 369
269 400
286 426
308 458
329 490
345 513
368 548
384 571
407 606
422 628
438 652
499 743
515 766
539 802

86 128
135 201
158 235
182 271
209 311
236 351
252 375
298 443
332 494
360 536
380 565
402 598
427 635
443 695
471 701
487 725
515 766
530 789
546 812
620 923
636 946
665 990

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 036150B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.
Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-10

34

Draka Marine Shipboard Cables

BOSTMARINE TYPE X CONTROL CABLE


multi-conductor / unarmored & armored
18, 16 and 14 AWG / 600V
APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated
VW1. Thickness as shown in tables on the reverse.

3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.

CustRef X-07

35

DUSA_X07_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-501

BOSTMARINE TYPE X CONTROL CABLE


multi-conductor / unarmored & armored
18, 16 and 14 AWG / 600V
18 AWG 1.0 mm2
TPC
Cable Type

Part
Number of
Number* Conductors

C18XT-2
C18XT-3
C18XT-4
C18XT-7
C18XT-10
C18XT-14
C18XT-19
C18XT-24
C18XT-30
C18XT-37
C18XT-44
C18XT-61

036570
036571
036572
036573
036574
036575
036576
036577
036578
036579
036580
036581

2
3
4
7
10
14
19
24
30
37
44
61

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2

0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2

0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2
7/24.2

0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76
0.030 0.76

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

Cable Diameter Cable Weight


Armored Cable
(nom)
(approx)
Diameter (nom)
in mm Lbs/mft Kg/km
in mm
0.32 8.0
0.33 8.4
0.36 9.1
0.42 10.8
0.56 14.4
0.61 15.5
0.67 17.0
0.78 19.8
0.88 22.4
0.93 23.6
1.03 26.2
1.10 27.9

47 70
56 83
68 101
99 147
153 228
195 290
250 372
308 458
370 551
480 714
547 814
696 1036

0.375 9.5
0.385 9.8
0.415 10.5
0.475 12.1
0.615 15.6
0.665 16.9
0.725 18.4
0.835 21.2
0.915 23.2
0.985 25.0
1.085 27.6
1.155 29.3

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
67 100
77 115
90 134
125 186
187 278
232 345
290 432
354 527
422 628
535 796
608 905
761 1132

113 168
124 185
142 211
184 274
265 394
316 470
383 570
462 687
543 808
662 985
748 1113
910 1354

16 AWG 1.3 mm2


TPC
Cable Type

Part
Number of
Number* Conductors

C16XT-2
C16XT-3
C16XT-4
C16XT-7
C16XT-10
C16XT-14
C16XT-19
C16XT-24
C16XT-30
C16XT-37
C16XT-44
C16XT-61

036582
036583
036584
036585
036053
036586
036587
036588
036589
036590
036591
036592

2
3
4
7
10
14
19
24
30
37
44
61

Cable Diameter Cable Weight


Armored Cable
(nom)
(approx)
Diameter (nom)
in mm Lbs/mft Kg/km
in mm
0.34 8.6
0.36 9.1
0.39 9.9
0.46 11.7
0.61 15.6
0.67 16.9
0.73 18.7
0.90 22.9
0.95 24.1
1.02 25.9
1.16 29.3
1.27 32.4

57 85
71 106
87 129
129 192
197 293
255 379
328 488
444 661
529 787
631 939
748 1113
980 1458

0.395 10.0
0.415 10.5
0.445 11.3
0.515 13.1
0.665 16.9
0.725 18.4
0.785 19.9
0.955 24.3
1.005 25.5
1.075 27.3
1.215 30.9
1.325 33.7

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
78 116
93 138
111 165
157 234
234 348
295 439
372 553
497 740
585 870
691 1028
816 1214
1054 1568

127 189
145 216
167 248
222 330
318 473
388 577
472 702
620 923
715 1064
830 1235
974 1449
1227 1825

14 AWG 2.1 mm2


TPC
Cable Type

Part
Number of
Number* Conductors

C14XT-2
C14XT-3
C14XT-4
C14XT-7
C14XT-10
C14XT-14
C14XT-19
C14XT-24
C14XT-30
C14XT-37
C14XT-44
C14XT-61

036593
036594
036595
036057
036596
036058
036597
036059
036598
036599
036600
036601

2
3
4
7
10
14
19
24
30
37
44
61

Cable Diameter Cable Weight


Armored Cable
(nom)
(approx)
Diameter (nom)
in mm Lbs/mft Kg/km
in mm
0.37 9.4
0.39 9.9
0.42 10.8
0.51 12.8
0.68 17.1
0.73 18.5
0.81 20.6
0.99 25.1
1.05 26.7
1.13 28.7
1.27 32.3
1.40 35.4

72 107
92 137
114 170
173 257
261 388
342 509
444 661
593 882
714 1063
856 1274
1010 1503
1350 2009

0.425 10.8
0.445 11.3
0.475 12.1
0.565 14.4
0.735 18.7
0.785 19.9
0.865 22.0
1.045 26.5
1.105 28.1
1.185 30.1
1.325 33.7
1.455 37.0

Aluminum arm.
Bronze arm.
Cable Weight
Cable Weight
Lbs/mft Kg/km Lbs/mft Kg/km
95 141
116 173
140 208
204 306
302 449
386 574
492 732
651 969
776 1155
922 1372
1084 1613
1432 2131

148 220
172 256
199 296
275 409
396 589
486 723
603 897
786 1170
919 1367
1076 1601
1257 1870
1621 2412

*NOTE: For aluminum armored versions, add an A (ex. 036570A). For bronze armored versions, add a B (ex. 036570B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef X-08

36

Draka Marine Shipboard Cables

BOSTMARINE TYPE X POWER CABLE


four conductor / unarmored & armored
14 AWG to 500 MCM / 600V
APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated
VW1. Thickness as shown in tables on the reverse.

3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.

CustRef X-05

37

DUSA_X05_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-501

BOSTMARINE TYPE X POWER CABLE


four conductor / unarmored
14 AWG to 500 MCM / 600V
TPC
Cable Type

Part
Number

Conductor Size
AWG/MCM mm2

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

FXT-4
FXT-6
FXT-10
FXT-16
FXT-26
FXT-41
FXT-66
FXT-83
FXT-106
FXT-133
FXT-168
FXT-212
FXT-250
FXT-300
FXT-350
FXT-400
FXT-500

036563
036564
036052
036565
036566
036015
036011
030143
030144
030145
030146
030147
030183
036568
030389
036569
030647

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65

0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79

0.440 11.2
0.485 12.3
0.575 14.6
0.730 18.5
0.830 21.1
0.990 25.1
1.140 29.0
1.290 32.8
1.390 35.3
1.500 38.1
1.625 41.3
1.830 46.5
2.000 50.8
2.130 54.1
2.260 57.4
2.370 60.2
2.580 65.5

120 179
164 244
241 359
382 568
542 806
824 1226
1205 1793
1500 2232
1782 2652
2220 3303
2706 4027
3444 5125
4002 5955
4680 6964
5464 8130
6140 9136
7560 11250

four conductor / aluminum or bronze armored


14 AWG to 500 MCM / 600V
TPC
Cable Type

Part
Number*

Conductor Size
AWG/MCM mm2

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

FXT-4
FXT-6
FXT-10
FXT-16
FXT-26
FXT-41
FXT-66
FXT-83
FXT-106
FXT-133
FXT-168
FXT-212
FXT-250
FXT-300
FXT-350
FXT-400
FXT-500

036563*
036564*
036052*
036565*
036566*
036015*
036011*
030143*
030144*
030145*
030146*
030147*
030183*
036568*
030389*
036569*
030647*

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65

0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79

0.495 12.6
0.540 13.7
0.630 16.0
0.785 19.9
0.885 22.5
1.045 26.5
1.195 30.4
1.345 34.2
1.445 36.7
1.555 39.5
1.680 42.7
1.885 47.9
2.055 52.2
2.185 55.5
2.315 58.8
2.425 61.6
2.635 66.9

147 219
193 287
276 411
426 634
591 879
882 1312
1272 1893
1576 2345
1863 2772
2308 3434
2801 4168
3551 5284
4118 6128
4804 7148
5595 8325
6278 9342
7710 11472

209 311
262 390
356 530
526 783
705 1049
1017 1513
1427 2123
1750 2604
2051 3052
2510 3735
3020 4494
3797 5650
4387 6528
5090 7574
5899 8778
6595 9813
8055 11986

*NOTE: For aluminum armored versions, add an A (ex. 036563A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 1281-209-3857 fax www.drakausa.com

CustRef X-06

38

Draka Marine Shipboard Cables

BOSTMARINE TYPE X POWER CABLE


three conductor / unarmored & armored
14 AWG to 1000 MCM / 600V
APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated
VW1. Thickness as shown in tables on the reverse.

3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.

CustRef X-03

39

DUSA_X03_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-501

BOSTMARINE TYPE X POWER CABLE


three conductor / unarmored
14 AWG to 1000 MCM / 600V
TPC
Cable Type

Part
Number

Conductor
Size

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TXT-4
TXT-6
TXT-10
TXT-16
TXT-26
TXT-41
TXT-66
TXT-83
TXT-106
TXT-133
TXT-168
TXT-212
TXT-250
TXT-300
TXT-350
TXT-400
TXT-500
TXT-750
TXT-1000

030125
030113
036010
036009
036055
036008
036007
030126
030127
030140
030141
030142
030158
036559
030124
030200
030647
036561
036562

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
750 380.0
1000 507.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/110.9
61/128.0

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.080 2.03
0.080 2.03

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.140 3.56
0.140 3.56

0.400 10.2
0.440 11.2
0.500 12.7
0.670 17.1
0.750 19.1
0.900 23.0
1.030 26.2
1.160 29.5
1.255 31.9
1.355 34.4
1.470 37.3
1.595 40.5
1.810 46.0
1.930 49.0
2.040 51.8
2.140 54.4
2.330 59.2
2.865 72.8
3.200 81.3

90 134
120 179
170 253
280 417
395 588
570 848
875 1302
1090 1622
1320 1964
1615 2403
1980 2947
2435 3624
2965 4412
3485 5186
4005 5960
4525 6734
5545 8252
8420 12530
11000 16370

three conductor / aluminum or bronze armored


14 AWG to 1000 MCM / 600V
TPC
Cable Type

Part
Number*

Conductor Size
AWG/MCM mm2

Stranding
Type

Insulationj
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

TXT-4
TXT-6
TXT-10
TXT-16
TXT-26
TXT-41
TXT-66
TXT-83
TXT-106
TXT-133
TXT-168
TXT-212
TXT-250
TXT-300
TXT-350
TXT-400
TXT-500
TXT-750
TXT-1000

030125*
030113*
036010*
036009*
036055*
036008*
036007*
030126*
030127*
030140*
030141*
030142*
030158*
036559*
030124*
030200*
030647*
036561*
036562*

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
750 380.0
1000 507.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/110.9
61/128.0

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.080 2.03
0.080 2.03

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.140 3.56
0.140 3.56

0.440 11.2
0.490 12.5
0.550 14.0
0.720 18.3
0.880 22.4
0.950 24.2
1.080 27.6
1.210 30.8
1.310 33.3
1.410 35.8
1.520 38.6
1.650 41.9
1.860 47.3
1.980 50.3
2.090 53.1
2.190 55.7
2.380 60.5
2.920 74.2
3.250 82.6

115 171
147 219
200 298
320 476
440 655
623 927
936 1393
1158 1732
1394 2074
1694 2521
2066 3074
2528 3762
3070 4568
3597 5352
4124 6137
4649 6918
5680 8452
8586 12776
11185 16643

171 254
209 311
270 402
413 615
543 808
746 1110
1076 1601
1316 1958
1564 2327
1878 2794
2265 3370
2743 4082
3314 4931
3857 5739
4398 6544
4937 7346
5993 8918
8969 13346
11613 17280

*NOTE: For aluminum armored versions, add an A (ex. 036012A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 1281-209-3857 fax www.drakausa.com

CustRef X-04

40

Draka Marine Shipboard Cables

BOSTMARINE TYPE X POWER CABLE


two conductor / unarmored & armored
14 AWG to 1000 MCM / 600V
APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated
VW1. Thickness as shown in tables on the reverse.

3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.

CustRef X-01

41

DUSA_X01_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-501

BOSTMARINE TYPE X POWER CABLE


two conductor / unarmored
14 AWG to 1000 MCM / 600V
TPC
Cable Type

Part
Number

Conductor
Size

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

DXT-4
DXT-6
DXT-10
DXT-16
DXT-26
DXT-41
DXT-66
DXT-83
DXT-106
DXT-133
DXT-168
DXT-212
DXT-250
DXT-300
DXT-350
DXT-400
DXT-500
DXT-600
DXT-750
DXT-1000

036012
036013
036050
036051
036542
036543
036544
036545
036546
036547
036548
036549
036550
036551
036552
036553
036554
036555
036556
036557

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
600 304.0
750 380.0
1000 507.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/99.2
61/110.9
61/128.0

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.080 2.03
0.080 2.03
0.080 2.03

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.140 3.56

0.380 9.7
0.420 10.7
0.470 11.9
0.630 16.0
0.705 17.9
0.810 20.6
0.970 24.6
1.090 27.7
1.180 30.0
1.270 32.3
1.380 35.1
1.490 37.8
1.630 41.4
1.810 46.0
1.910 48.5
2.005 50.9
2.180 55.4
2.405 61.1
2.620 66.5
2.995 76.1

81 121
98 146
138 205
234 348
280 417
448 667
682 1015
835 1242
915 1362
1222 1818
1491 2219
1805 2686
1945 2894
2385 3549
2735 4070
3080 4584
3755 5588
4530 6741
5550 8259
7390 10997

two conductor / aluminum or bronze armored


14 AWG to 1000 MCM / 600V
TPC
Cable Type

Part
Number*

Conductor Size
AWG/MCM mm2

Stranding
Type

Insulationj
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

DXT-4
DXT-6
DXT-10
DXT-16
DXT-26
DXT-41
DXT-66
DXT-83
DXT-106
DXT-133
DXT-168
DXT-212
DXT-250
DXT-300
DXT-350
DXT-400
DXT-500
DXT-600
DXT-750
DXT-1000

036012*
036013*
036050*
036051*
036542*
036543*
036544*
036545*
036546*
036547*
036548*
036549*
036550*
036551*
036552*
036553*
036554*
036555*
036556*
036557*

14 2.1
12 3.3
10 5.3
8 8.4
6 13.3
4 21.1
2 33.6
1 42.4
1/0 53.5
2/0 67.4
3/0 85.0
4/0 107.2
250 127.0
300 152.0
350 177.0
400 203.0
500 253.0
600 304.0
750 380.0
1000 507.0

7/24.2
7/30.5
7/38.5
7/48.6
7/61.2
7/77.2
7/97.4
19/66.4
19/74.5
19/83.7
19/94.0
19/105.5
37/82.2
37/90.0
37/97.3
37/104.0
37/116.2
61/99.2
61/110.9
61/128.0

0.030 0.76
0.030 0.76
0.030 0.76
0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.055 1.40
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.065 1.65
0.080 2.03
0.080 2.03
0.080 2.03

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.110 2.79
0.140 3.56

0.435 11.0
0.475 12.1
0.525 13.3
0.685 17.4
0.760 19.3
0.865 22.0
1.025 26.0
1.145 29.1
1.235 31.4
1.325 33.7
1.435 36.4
1.545 39.2
1.685 42.3
1.865 47.4
1.965 49.9
2.060 52.3
2.235 56.8
2.460 62.5
2.675 67.9
3.055 77.6

104 155
124 185
167 248
272 405
322 479
496 738
739 1100
899 1338
984 1464
1296 1928
1572 2339
1892 2815
2040 3036
2490 3705
2846 4235
3197 4757
3882 5776
4670 6949
5702 8485
7563 11254

159 237
183 272
233 347
359 534
419 623
607 903
872 1298
1047 1558
1145 1704
1469 2632
1758 2616
2093 3114
2260 3363
2734 4068
3103 4617
3466 5157
4174 6211
4991 7427
6053 9007
7964 11850

*
NOTE: For aluminum armored versions, add an A (ex. 036012A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 1281-209-3857 fax www.drakausa.com

CustRef X-02

42

Draka Marine Shipboard Cables

BOSTMARINE TYPE X SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
16 AWG 1.31 mm2 / 600V
APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated
VW1. Thickness as shown in tables on the reverse.

3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.

CustRef X-13

43

DUSA_X13_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-511

BOSTMARINE TYPE X SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored
16 AWG 1.31 mm2 / 600V
TPC
Cable Type

Part
Number

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP16(IS)XT-1
TP16(IS-OS)XT-2
TP16(IS-OS)XT-3
TP16(IS-OS)XT-4
TP16(IS-OS)XT-5
TP16(IS-OS)XT-6
TP16(IS-OS)XT-7
TP16(IS-OS)XT-8
TP16(IS-OS)XT-9
TP16(IS-OS)XT-10
TP16(IS-OS)XT-11
TP16(IS-OS)XT-12
TP16(IS-OS)XT-13
TP16(IS-OS)XT-14
TP16(IS-OS)XT-15
TP16(IS-OS)XT-16
TP16(IS-OS)XT-17
TP16(IS-OS)XT-18
TP16(IS-OS)XT-19
TP16(IS-OS)XT-20
TP16(IS-OS)XT-21
TP16(IS-OS)XT-22

036646
036647
036648
036649
036650
036651
036652
036653
036654
036655
036656
036657
036658
036659
036660
036661
036662
036663
036664
036665
036666
036667

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.32 8.1
0.50 12.7
0.56 14.2
0.61 15.5
0.67 17.0
0.73 18.5
0.73 18.5
0.79 20.1
0.89 22.6
0.97 24.6
0.99 25.1
0.99 25.1
1.04 26.4
1.04 26.4
1.10 27.9
1.10 27.9
1.15 29.2
1.15 29.2
1.15 29.2
1.21 30.7
1.21 30.7
1.28 32.5

56 83
104 155
153 228
190 283
227 338
265 394
295 439
332 494
370 551
449 668
487 724
516 768
555 826
585 870
621 924
654 974
694 1033
724 1078
754 1122
790 1176
824 1226
865 1287

indiv. & overall shielded twisted pair / aluminum or bronze armored


16 AWG 1.31 mm2 / 600V
TPC
Cable Type

Part
Number*

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

TP16(IS)XT-1
TP16(IS-OS)XT-2
TP16(IS-OS)XT-3
TP16(IS-OS)XT-4
TP16(IS-OS)XT-5
TP16(IS-OS)XT-6
TP16(IS-OS)XT-7
TP16(IS-OS)XT-8
TP16(IS-OS)XT-9
TP16(IS-OS)XT-10
TP16(IS-OS)XT-11
TP16(IS-OS)XT-12
TP16(IS-OS)XT-13
TP16(IS-OS)XT-14
TP16(IS-OS)XT-15
TP16(IS-OS)XT-16
TP16(IS-OS)XT-17
TP16(IS-OS)XT-18
TP16(IS-OS)XT-19
TP16(IS-OS)XT-20
TP16(IS-OS)XT-21
TP16(IS-OS)XT-22

036646*
036647*
036648*
036649*
036650*
036651*
036652*
036653*
036654*
036655*
036656*
036657*
036658*
036659*
036660*
036661*
036662*
036663*
036664*
036665*
036666*
036667*

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2
7/19.2

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.375 9.5
0.555 14.1
0.615 15.6
0.665 16.9
0.725 18.4
0.785 19.9
0.785 19.9
0.845 21.4
0.945 24.0
1.025 26.0
1.045 26.5
1.045 26.5
1.095 27.8
1.095 27.8
1.155 29.3
1.155 29.3
1.205 24.2
1.205 24.2
1.205 24.2
1.265 32.1
1.265 32.1
1.335 33.9

76 113
134 199
187 278
227 338
267 397
309 460
368 548
379 564
423 629
506 753
545 811
574 854
616 917
646 961
686 1021
719 1070
762 1134
792 1178
822 1123
861 1281
895 1332
940 1399

122 182
204 304
265 394
311 463
360 534
409 609
439 653
487 725
544 809
639 951
680 1012
709 1055
758 1128
788 1173
835 1242
868 1292
918 1366
948 1411
978 1455
1025 1525
1059 1576
1113 1656

*NOTE: For aluminum armored versions, add an A (ex. 036646A). For bronze armored versions, add a B (ex. 036646B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.
Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef X-14

44

Draka Marine Shipboard Cables

BOSTMARINE TYPE X SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
18 AWG 0.82 mm2 / 600V
APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated
VW1. Thickness as shown in tables on the reverse.

3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.

CustRef X-11

45

DUSA_X11_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-511

BOSTMARINE TYPE X SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored
18 AWG 0.82 mm2 / 600V
TPC
Cable Type

Part
Number

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP18(IS)XT-1
TP18(IS-OS)XT-2
TP18(IS-OS)XT-3
TP18(IS-OS)XT-4
TP18(IS-OS)XT-5
TP18(IS-OS)XT-6
TP18(IS-OS)XT-7
TP18(IS-OS)XT-8
TP18(IS-OS)XT-9
TP18(IS-OS)XT-10
TP18(IS-OS)XT-11
TP18(IS-OS)XT-12
TP18(IS-OS)XT-13
TP18(IS-OS)XT-14
TP18(IS-OS)XT-15
TP18(IS-OS)XT-16
TP18(IS-OS)XT-17
TP18(IS-OS)XT-18
TP18(IS-OS)XT-19
TP18(IS-OS)XT-20
TP18(IS-OS)XT-21
TP18(IS-OS)XT-22

036624
036625
036626
036627
036628
036629
036630
036631
036632
036633
036634
036635
036636
036637
036638
036639
036640
036641
036642
036643
036644
036645

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.30 7.6
0.45 11.4
0.48 12.2
0.59 15.0
0.61 15.5
0.66 16.8
0.66 16.8
0.72 18.3
0.78 19.8
0.89 22.6
0.91 23.1
0.91 23.1
0.96 24.4
0.96 24.4
1.01 25.7
1.01 25.7
1.06 26.9
1.06 26.9
1.06 26.9
1.11 28.2
1.11 28.2
1.16 29.5

46 68
85 126
109 162
153 228
182 271
211 314
232 346
262 390
290 432
359 534
346 516
368 548
438 652
459 684
490 729
512 762
543 808
565 840
586 872
619 921
639 951
671 998

indiv. & overall shielded twisted pair / aluminum & bronze armored
18 AWG 0.82 mm2 / 600V
TPC
Cable Type

Part
Number*

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

TP18(IS)XT-1
TP18(IS-OS)XT-2
TP18(IS-OS)XT-3
TP18(IS-OS)XT-4
TP18(IS-OS)XT-5
TP18(IS-OS)XT-6
TP18(IS-OS)XT-7
TP18(IS-OS)XT-8
TP18(IS-OS)XT-9
TP18(IS-OS)XT-10
TP18(IS-OS)XT-11
TP18(IS-OS)XT-12
TP18(IS-OS)XT-13
TP18(IS-OS)XT-14
TP18(IS-OS)XT-15
TP18(IS-OS)XT-16
TP18(IS-OS)XT-17
TP18(IS-OS)XT-18
TP18(IS-OS)XT-19
TP18(IS-OS)XT-20
TP18(IS-OS)XT-21
TP18(IS-OS)XT-22

036624*
036625*
036626*
036627*
036628*
036629*
036630*
036631*
036632*
036633*
036634*
036635*
036636*
036637*
036638*
036639*
036640*
036641*
036642*
036643*
036644*
036645*

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2
7/15.2

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.355 9.0
0.505 12.8
0.535 13.6
0.645 16.4
0.665 16.9
0.715 18.2
0.715 18.2
0.775 19.7
0.835 21.2
0.925 23.5
0.965 24.5
0.965 24.5
1.015 25.8
1.015 25.8
1.065 27.1
1.065 27.1
1.115 28.3
1.115 28.3
1.115 28.3
1.165 29.6
1.165 29.6
1.215 30.9

65 97
112 167
138 205
188 280
219 326
251 373
272 405
305 454
336 500
364 542
393 585
422 628
495 737
516 768
550 818
572 851
605 900
627 933
648 964
684 1018
704 1048
739 1100

108 161
176 262
206 307
271 403
303 451
342 509
363 540
404 601
444 661
478 711
512 762
546 812
626 931
647 963
687 1022
709 1055
750 1116
772 1149
793 1180
835 1242
855 1272
897 1335

*NOTE: For aluminum armored versions, add an A (ex. 036624A). For bronze armored versions, add a B (ex. 036624B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.
Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef X-12

46

Draka Marine Shipboard Cables

BOSTMARINE TYPE X SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
20 AWG 0.52 mm2 / 300V
APPLICATIONS
BOSTMARINE Type X 300 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 300
volts. Type X cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES

IEEE STANDARD 45 (1998)

IEEE STANDARD 1580 (2001)

UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated
VW1. Thickness as shown in tables on the reverse.

3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.

CustRef X-09

47

DUSA_X09_1005

DRAKA MOG BOSTMARINE

Manufactured to Draka Cableteq USA Specifying Standard J-511

BOSTMARINE TYPE X SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored
20 AWG 0.52 mm2 / 300V
TPC
Cable Type

Part
Number

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP20(IS)XT-1
TP20(IS-OS)XT-2
TP20(IS-OS)XT-3
TP20(IS-OS)XT-4
TP20(IS-OS)XT-5
TP20(IS-OS)XT-6
TP20(IS-OS)XT-7
TP20(IS-OS)XT-8
TP20(IS-OS)XT-9
TP20(IS-OS)XT-10
TP20(IS-OS)XT-11
TP20(IS-OS)XT-12
TP20(IS-OS)XT-13
TP20(IS-OS)XT-14
TP20(IS-OS)XT-15
TP20(IS-OS)XT-16
TP20(IS-OS)XT-17
TP20(IS-OS)XT-18
TP20(IS-OS)XT-19
TP20(IS-OS)XT-20
TP20(IS-OS)XT-21
TP20(IS-OS)XT-22

036602
036603
036604
036605
036606
036607
036608
036609
036610
036611
036612
036613
036614
036615
036616
036617
036618
036619
036620
036621
036622
036623

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.28 7.1
0.41 10.4
0.43 10.9
0.48 12.2
0.55 14.0
0.60 15.2
0.60 15.2
0.65 16.5
0.69 17.5
0.75 19.1
0.78 19.8
0.78 19.8
0.82 20.8
0.82 20.8
0.90 22.9
0.90 22.9
0.95 24.1
0.95 24.1
0.95 24.1
0.99 25.1
0.99 25.1
1.04 26.4

36 54
64 95
80 119
97 144
132 196
152 226
164 244
185 275
204 303
226 336
242 360
256 381
275 409
289 430
346 515
359 534
381 566
395 587
408 608
429 638
444 661
466 694

indiv. & overall shielded twisted pair / aluminum or bronze armored


20 AWG 0.52 mm2 / 300V
TPC
Cable Type

Part
Number*

Number of
Pairs

Stranding
Type

Insulation
Thickness
in mm

Jacket
Thickness
in mm

Armored
Cable Diameter
in mm

Aluminum arm.
Cable Weight
Lbs/mft Kg/km

Bronze arm.
Cable Weight
Lbs/mft Kg/km

TP20(IS)XT-1
TP20(IS-OS)XT-2
TP20(IS-OS)XT-3
TP20(IS-OS)XT-4
TP20(IS-OS)XT-5
TP20(IS-OS)XT-6
TP20(IS-OS)XT-7
TP20(IS-OS)XT-8
TP20(IS-OS)XT-9
TP20(IS-OS)XT-10
TP20(IS-OS)XT-11
TP20(IS-OS)XT-12
TP20(IS-OS)XT-13
TP20(IS-OS)XT-14
TP20(IS-OS)XT-15
TP20(IS-OS)XT-16
TP20(IS-OS)XT-17
TP20(IS-OS)XT-18
TP20(IS-OS)XT-19
TP20(IS-OS)XT-20
TP20(IS-OS)XT-21
TP20(IS-OS)XT-22

036602*
036603*
036604*
036605*
036606*
036607*
036608*
036609*
036610*
036611*
036612*
036613*
036614*
036615*
036616*
036617*
036618*
036619*
036620*
036621*
036622*
036623*

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22

7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1
7/12.1

0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64
0.025 0.64

0.045 1.14
0.045 1.14
0.045 1.14
0.045 1.14
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.060 1.52
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03
0.080 2.03

0.335 8.5
0.465 11.8
0.485 12.3
0.535 13.6
0.605 15.4
0.655 16.6
0.655 16.6
0.705 17.9
0.745 18.9
0.805 20.4
0.835 21.2
0.835 21.2
0.875 22.2
0.875 22.2
0.955 24.3
0.955 24.3
1.005 25.5
1.005 25.5
1.005 25.5
1.045 26.5
1.045 26.5
1.095 27.8

54 80
89 132
106 158
126 187
165 246
188 280
200 298
224 333
245 365
271 403
288 429
302 449
324 482
338 503
399 594
412 613
437 650
451 671
464 690
487 725
502 747
527 784

95 141
147 219
167 248
194 289
242 360
271 403
283 421
314 467
340 506
374 556
396 589
410 610
436 649
450 670
522 777
535 796
567 844
584 869
594 884
622 926
637 948
669 995

*NOTE: For aluminum armored versions, add an A (ex. 036602A). For bronze armored versions, add a B (ex. 036602B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.
Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef X-10

48

Bostrig Type P
0807
Page 17 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed

TYPE P CONTROL CABLE


600V or 0.6/1kV
12 & 10 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

49

www.DrakaMOG.com

Bostrig Type P
0807
Page 18 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV


multi-conductor / armored and sheathed
12 & 10 AWG / 600V or 0.6/1kV
12 AWG 3.08 mm2
Type
Designation
C12PNBS-2
C12PNBS-3
C12PNBS-4
C12PNBS-5
C12PNBS-6
C12PNBS-7
C12PNBS-8
C12PNBS-10
C12PNBS-12
C12PNBS-16
C12PNBS-20
C12PNBS-24
C12PNBS-30
C12PNBS-37
C12PNBS-44
C12PNBS-60
C12PNBS-91

Draka
Number
026300
026301
026302
026303
026304
026305
026306
026307
026308
026309
026310
026311
026312
026313
026314
026315
026316

Number of
Conductors
2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76

Sheath
Thickness
in mm
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.110 2.8
.110 2.8
.125 3.2
.125 3.2

Cable Diameter
(nominal)
in mm
.605 15.4
.620 15.8
.665 16.9
.710 18.0
.750 19.1
.750 19.1
.800 20.3
.940 23.9
.965 24.5
1.085 27.6
1.175 29.9
1.280 32.5
1.340 34.0
1.490 37.9
1.640 41.7
1.875 47.6
2.180 55.4

Cable Weight
(approximate)
Lbs/mft Kg/km
250 372
285 424
325 484
370 551
415 618
435 647
485 722
620 923
680 1012
870 1295
1020 1518
1180 1756
1370 2039
1685 2508
1955 2909
2630 3914
3670 5462

Number of
Conductors
2
3
4
5
6
7
8
10

Insulation
Thickness
in mm
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76

Sheath
Thickness
in mm
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.080 2.0
.080 2.0
.080 2.0
.080 2.0

Cable Diameter
(nominal)
in mm
.670 17.0
.695 17.7
.750 19.1
.820 20.8
.895 22.7
.895 22.7
.950 24.1
1.112 28.5

Cable Weight
(approximate)
Lbs/mft Kg/km
315 469
370 551
430 640
500 744
600 893
640 952
710 1057
910 1354

10 AWG 5.53 mm2


Type
Designation
C10PNBS-2
C10PNBS-3
C10PNBS-4
C10PNBS-5
C10PNBS-6
C10PNBS-7
C10PNBS-8
C100PNBS-10

Draka
Number
026317
026318
026319
026320
026321
026322
026323
026324

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
12
6,503 3.30
10 10,908 5.53

95C
26
37

100C
31
41

110C
33
44

50

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 41 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored

TYPE P CONTROL CABLE


600V or 0.6/1kV
12 & 10 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

51

www.DrakaMOG.com

Bostrig Type P
0807
Page 42 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


multi-conductor / unarmored
12 & 10 AWG / 600V or 0.6/1kV
12 AWG 3.08 mm2
Type
Designation
C12PN-2
C12PN-3
C12PN-4
C12PN-5
C12PN-6
C12PN-7
C12PN-8
C12PN-10
C12PN-12
C12PN-16
C12PN-20
C12PN-24
C12PN-30
C12PN-37
C12PN-44
C12PN-60
C12PN-91

Draka
Number
026224
026225
026226
026227
026228
026229
026230
026231
026232
026233
026234
026235
026236
026237
026238
026239
026240

Number of
Conductors
2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76

Sheath
Thickness
in mm
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.080 2.0
.110 2.8
.125 3.2

Cable Diameter
(nominal)
in mm
.425 10.8
.440 11.2
.475 12.1
.525 13.3
.570 14.5
.570 14.5
.620 15.6
.720 18.3
.745 18.9
.865 22.0
.955 24.3
1.060 26.9
1.120 28.5
1.210 30.7
1.355 34.4
1.565 39.8
1.880 47.8

Cable Weight
(approximate)
Lbs/mft Kg/km
100 149
135 201
155 231
190 283
220 327
245 365
280 417
355 528
400 595
550 818
680 1012
795 1183
955 1421
1140 1697
1390 2069
1880 2798
2800 4167

Number of
Conductors
2
3
4
5
6
7
8
10

Insulation
Thickness
in mm
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76
.030 0.76

Sheath
Thickness
in mm
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.060 1.5
.080 2.0

Cable Diameter
(nominal)
in mm
.490 12.5
.520 13.2
.565 14.4
.620 15.8
.675 17.2
.675 17.2
.730 18.5
.895 22.7

Cable Weight
(approximate)
Lbs/mft Kg/km
115 171
200 298
240 357
295 439
350 521
390 580
445 662
590 878

10 AWG 5.53 mm2


Type
Designation
C10PN-2
C10PN-3
C10PN-4
C10PN-5
C10PN-6
C10PN-7
C10PN-8
C10PN-10

Draka
Number
026241
026242
026243
026244
026245
026246
026247
026248

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
12
6,503 3.30
10 10,908 5.53

95C
26
37

100C
31
41

110C
33
44

52

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 39 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored

TYPE P CONTROL CABLE


600V or 0.6/1kV
14 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on oppposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

53

www.DrakaMOG.com

Bostrig Type P
0807
Page 40 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


multi-conductor / unarmored
14 AWG / 600V or 0.6/1kV 1.94 mm2
Type
Designation

Draka
Number

Number of
Conductors

C14PN-2
C14PN-3
C14PN-4
C14PN-5
C14PN-6
C14PN-7
C14PN-8
C14PN-10
C14PN-12
C14PN-16
C14PN-20
C14PN-24
C14PN-30
C14PN-37
C14PN-44
C14PN-60
C14PN-91

026207
026208
026209
026210
026211
026212
026213
026214
026215
026216
026217
026218
026219
026220
026297
026298
026299

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080

.380 6.7
.390 9.9
.430 10.9
.475 12.1
.515 13.1
.515 13.1
.560 14.2
.650 16.5
.670 17.0
.740 18.8
.820 20.8
.950 24.1
1.005 25.5
1.080 27.4
1.215 30.9
1.345 34.2
1.650 41.9

77 115
100 149
115 171
147 218
165 246
180 268
210 313
260 387
290 432
375 558
495 737
585 871
695 1034
850 1265
990 1473
1300 1935
1980 2947

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
14
4,106 2.08

95C
20

100C
25

110C
27

54

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 15 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed

TYPE P CONTROL CABLE


600V or 0.6/1kV
14 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

55

www.DrakaMOG.com

Bostrig Type P
0807
Page 16 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV


multi-conductor / armored and sheathed
14 AWG / 600V or 0.6/1kV 1.94 mm2
Type
Designation

Draka
Number

Number of
Conductors

C14PNBS-2
C14PNBS-3
C14PNBS-4
C14PNBS-5
C14PNBS-6
C14PNBS-7
C14PNBS-8
C14PNBS-10
C14PNBS-12
C14PNBS-16
C14PNBS-20
C14PNBS-24
C14PNBS-30
C14PNBS-37
C14PNBS-44
C14PNBS-60
C14PNBS-91

026283
026284
026285
026286
026287
026288
026289
026290
026291
026292
026293
026294
026295
026296
026297
026298
026299

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.110
.110
.115

.560 14.2
.575 14.6
.620 15.8
.660 16.8
.700 17.8
.700 17.8
.740 18.8
.860 21.8
.890 22.6
.960 24.4
1.040 26.4
1.170 29.7
1.225 31.1
1.305 33.2
1.495 38.0
1.625 41.3
1.950 49.5

205 305
240 357
275 409
305 454
340 506
355 528
395 588
500 744
550 818
655 975
770 1146
930 1384
1060 1577
1240 1845
1510 2247
1880 2298
2750 4093

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.8
2.8
2.9

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with 4 or moreCurrent Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
14
4,106 2.08

95C
20

100C
25

110C
27

56

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 37 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored

TYPE P CONTROL CABLE


600V or 0.6/1kV
16 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

57

www.DrakaMOG.com

Bostrig Type P
0807
Page 38 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


multi-conductor / unarmored
16 AWG / 600V or 0.6/1kV 1.23 mm2
Type
Designation

Draka
Number

Number of
Conductors

C16PN-2
C16PN-3
C16PN-4
C16PN-5
C16PN-6
C16PN-7
C16PN-8
C16PN-10
C16PN-12
C16PN-16
C16PN-20
C16PN-24
C16PN-30
C16PN-37
C16PN-44
C16PN-60
C16PN-91

026190
026191
026192
026193
026194
026195
026196
026197
026198
026199
026200
026201
026202
026203
026204
026205
026206

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080

.355 9.0
.370 9.4
.400 10.2
.440 11.2
.475 12.1
.475 12.1
.540 13.7
.595 15.1
.610 15.5
.675 17.2
.745 18.9
.840 21.3
.915 23.2
.985 25.0
1.100 27.9
1.220 31.0
1.480 37.6

65 97
80 119
95 141
115 171
135 201
145 216
160 238
200 298
225 335
285 424
350 521
440 655
520 774
625 930
735 1094
960 1429
1470 2188

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
16
2,061 1.32

95C
16

100C
17

110C
18

58

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 13 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed

TYPE P CONTROL CABLE


600V or 0.6/1kV
16 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

59

www.DrakaMOG.com

Bostrig Type P
0807
Page 14 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV


multi-conductor / armored and sheathed
16 AWG / 600V or 0.6/1kV 1.23 mm2
Type
Designation
C16PNBS-2
C16PNBS-3
C16PNBS-4
C16PNBS-5
C16PNBS-6
C16PNBS-7
C16PNBS-8
C16PNBS-10
C16PNBS-12
C16PNBS-16
C16PNBS-20
C16PNBS-24
C16PNBS-30
C16PNBS-37
C16PNBS-44
C16PNBS-60
C16PNBS-91

Draka
Number

Number of
Conductors

026266
026267
0262668
026269
026270
026271
026272
026273
026274
026275
026276
026277
026278
026279
026280
026281
026282

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080
.080
.110
.110

.535 13.6
.545 13.8
.590 15.0
.620 15.8
.655 16.6
.655 16.6
.720 18.3
.775 19.7
.790 20.1
.895 22.7
.965 24.5
1.050 26.7
1.135 28.8
1.205 30.6
1.320 33.5
1.500 38.1
1.770 45.0

190 283
205 305
235 350
265 394
295 439
300 446
340 506
400 595
430 640
545 811
635 945
755 1124
865 1287
995 1480
1125 1674
1495 2225
2100 3125

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0
2.0
2.8
2.8

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with 4 or more Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
16
2,601 1.32

95C
16

100C
17

110C
18

60

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 35 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored

TYPE P CONTROL CABLE


600V or 0.6/1kV
18 AWG
1

Approvals

Applications
BostrigTM Type P Marine and Offshore Cable is
primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.
Bostrig cables have excellent resistance to oil, abrasion,
moisture, sunlight and ester-based mud (Type P-MR).
The standard insulation has a continuous operating
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an armored and
sheathed version.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Det Norske Veritas Type Approval Certificates E8792,
E8793, E8794, E8795 and E8796.
American Bureau of Shipping Approval Certificate
03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

61

www.DrakaMOG.com

Bostrig Type P
0807
Page 36 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


multi-conductor / unarmored
18 AWG / 600V or 0.6/1kV 0.96 mm2
Type
Designation

Draka
Number

Number of
Conductors

C18PN-2
C18PN-3
C18PN-4
C18PN-5
C18PN-6
C18PN-7
C18PN-8
C18PN-10
C18PN-12
C18PN-16
C18PN-20
C18PN-24
C18PN-30
C18PN-37
C18PN-44
C18PN-60
C18PN-91

026173
026174
026175
026176
026177
026178
026179
026180
026181
026182
026183
026184
026185
026186
026187
026188
026189

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080

.340 8.6
.360 9.1
.390 9.9
.425 10.8
.460 11.7
.460 11.7
.490 12.5
.570 14.5
.585 14.9
.660 16.8
.715 18.2
.790 20.1
.875 22.2
.940 23.9
1.055 26.8
1.165 29.6
1.390 35.3

55 82
70 104
85 127
100 149
120 179
130 193
140 208
175 260
195 290
250 372
305 454
355 528
455 677
545 811
640 952
835 1243
1220 1816

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
18
1,620 0.82

95C
11

100C
12

110C
13

62

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 11 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed

TYPE P CONTROL CABLE


600V or 0.6/1kV
18 AWG
1

Approvals

Applications
BostrigTM Type P Marine and Offshore Cable is
primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.
Bostrig cables have excellent resistance to oil, abrasion,
moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.
The standard insulation has a continuous operating
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Det Norske Veritas Type Approval Certificates E8792,
E8793, E8794, E8795 and E8796.
American Bureau of Shipping Approval Certificate
03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

63

www.DrakaMOG.com

Bostrig Type P
0807
Page 12 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV


multi-conductor / armored and sheathed
18 AWG / 600V or 0.6/1kV 0.96 mm2
Type
Designation

Draka
Number

Number of
Conductors

C18PNBS-2
C18PNBS-3
C18PNBS-4
C18PNBS-5
C18PNBS-6
C18PNBS-7
C18PNBS-8
C18PNBS-10
C18PNBS-12
C18PNBS-16
C18PNBS-20
C18PNBS-24
C18PNBS-30
C18PNBS-37
C18PNBS-44
C18PNBS-60
C18PNBS-91

026249
026250
026251
026252
026253
026254
026255
026256
026257
026258
026259
026260
026261
026262
026263
026264
026265

2
3
4
5
6
7
8
10
12
16
20
24
30
37
44
60
91

Insulation
Thickness
in mm
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030
.030

0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.060
.060
.060
.060
.060
.060
.060
.060
.060
.080
.080
.080
.080
.080
.080
.110
.110

.515 13.1
.540 13.7
.575 14.6
.605 15.4
.640 16.3
.640 16.3
.670 17.1
.750 19.1
.765 19.1
.885 22.5
.935 23.8
1.010 25.7
1.100 27.9
1.165 29.6
1.275 32.4
1.445 36.7
1.650 41.9

180 268
200 298
225 335
250 372
275 409
285 424
310 461
365 543
365 543
500 744
580 863
655 975
790 1176
900 1339
1035 1540
1355 2016
1860 2768

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
2.0
2.0
2.0
2.0
2.8
2.8

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all conductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3

Table 4

Three Conductor Cable, four Conductor

Cables with more than four Current Carrying Conductors

Cables with three Current Carrying


No of Conductors

Conductors 45C Ambient


Conductor Size
Gauge CMA mm2
18
1,620 0.82

95C
11

100C
12

110C
13

64

4-6
7-9
10-20
21-30
31-40
41-60
61 and greater

www.DrakaMOG.com

Derating Factor from 3


Conductor Ampacity
0.8
0.7
0.5
0.45
0.40
0.35
0.30

Bostrig Type P
0807
Page 61 of 62

BOSTRIG TYPE P-MR POWER CABLE


Single conductor / armored & sheathed
and unarmored ester-based mud resistant

TYPE P-MR POWER CABLE


2000V
2

4/0 AWG TO 1111 MCM

Applications

Approvals

BostrigTM Type P Mud Resistant Cable is primarily


designed for power, control, signal and instrumentation
applications for offshore, land rigs, marine vessels and
oil and gas drilling rigs. Instead of Polychloroprene
(Neoprene), they are sheathed in our proprietary
elastomeric formulation which is not only mud-resistant
but qualifies as a low-smoke zero-halogen (LSZH) cable
in accordance with IEEE 45 (1998), IEEE 1580 (2001)
and type approved as Type M.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Performance requirements of IEc 92-3.
Det Norske Veritas Type Approval Certificates E8797,
E8798, E8799 and E8800.
Manufactured to BIW Specifying Standard J104

This mud-resistant jacket is designed for use in areas


where ester-based drilling muds and fluids are present.
These cables are listed by ETL in accordance with IEEE
45 and type approved by DNV as resistant to NOVA
Plus, Petrofree LE and Petrofree drilling muds and
fluids. The cable was tested in accordance with NEK
606 for 56 days at 70C in each of the ester-based
muds mentioned above
This product can be manufactured in an unarmored
version.

Construction
1. Conductors
2. Insulation
3. Armor
4. Sheath

Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page.
A mylar separator is used over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580
(2001). Thickness as shown in tables on opposite page.

Features
Special ester-based mud-resistant jacket also provides superior resistance to oil,
abrasion, moisture, sunlight, crush and impact
Super-flexible construction
Meets IEEE 45 (1998) and IEEE 1580 (2001) for 600 and 2000 volts

Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 45 (1998), IEEE 1580 (2001), and
UL 1309/CSA 245 and IEEE 45 (1998) for 2000V.
Type approved by DNV.

65

www.DrakaMOG.com

Bostrig Type P
0807
Page 62 of 62

BOSTRIG TYPE P-MR POWER CABLE


single conductor / armored & sheathed and unarmored
4/0 AWG to 1111 MCM / 2000V
Armored & sheathed
Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
Impedance
(nominal)
(Phase-Neutral)
Inductance
Capacitance
in mm
/kft - /km mH/kft mH/km pF/ft pF/m

Ampacity
(measured @ C)
95 100 110

Cable Weight
(approximate)
Lbs/mft Kg/km

SPBM2KV(HD)-4/0

026034M

4/0 112.6

.080 2.0

1.040 26.4

0.07 0.2

0.11 0.4

146 479

335 351 376

1190 1771

SPBM2KV(HD)-262

026035M

262 133.1

.080 2.0

1.090 27.7

0.06 0.2

0.10 0.3

162 531

382 407 436

1360 2024

SPBM2KV(HD)-313

026036M

313 158.7

.080 2.0

1.155 29.3

0.06 0.2

0.10 0.3

175 574

426 455 487

1580 2351

SPBM2KV(HD)-373

026037M

373 189.2

.080 2.0

1.225 31.1

0.05 0.2

0.10 0.3

189 620

476 516 553

1800 2678

SPBM2KV(HD)-444

026038M

444 225.2

.080 2.0

1.295 32.9

0.05 0.2

0.10 0.3

205 672

531 588 630

2130 3169

SPBM2KV(HD)-535

026039M

535 271.3

.110 2.8

1.475 37.5

0.04 0.01

0.10 0.3

200 656

596 630 675

2620 3899

SPBM2KV(HD)-646

026040M

646 327.5

.110 2.8

1.575 40.0

0.04 0.01

0.10 0.3

216 708

670 731 7783

3050 4538

SPBM2KV(HD)-777

026041M

777 394.2

.110 2.8

1.665 42.3

0.04 0.01

0.10 0.3

236 774

754 822 881

3570 5312

SPBM2KV(HD)-1111

026042M

1111 563.0

.125 3.2

1.990 48.3

0.04 0.01

0.10 0.3

257 843

942 1025 1098

4780 7113

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

Ampacity
(measured @ C)
95 100 110

Cable Weight
(approximate)
Lbs/mft Kg/km

Unarmored
Type
Designation

Cable Diameter
Impedance
(nominal)
(Phase-Neutral)
Inductance
Capacitance
in mm
/kft- /km mH/kft mH/km pF/ft pF/m

SPM2KV(HD)-4/0

026015M

4/0 112.6

.105 2.7

.690 20.8

0.07 0.2

0.11 0.4

146 479

335 351 376

1060 1577

SPM2KV(HD)-262

026016M

262 133.1

.105 2.7

.820 22.1

0.06 0.2

0.10 0.3

162 531

382 407 436

1220 1815

SPM2KV(HD)-313

026017M

313 158.7

.105 2.7

.935 23.8

0.06 0.2

0.10 0.3

175 574

426 455 487

1430 2128

SPM2KV(HD)-373

026018M

373 189.2

.105 2.7

1.005 25.5

0.05 0.2

0.10 0.3

189 620

476 516 553

1640 2440

SPM2KV(HD)-444

026019M

444 225.2

.105 2.7

1.075 27.3

0.05 0.2

0.10 0.3

205 672

531 588 630

1940 2887

SPM2KV(HD)-535

026020M

535 271.3

.120 3.1

1.195 30.4

0.04 0.1

0.10 0.3

200 656

596 630 675

2370 3527

SPM2KV(HD)-646

026021M

646 327.5

.120 3.1

1.295 32.9

0.04 0.1

0.10 0.3

216 708

670 731 783

2800 4166

SPM2KV(HD)-777

026022M

777 394.2

.120 3.1

1.385 35.2

0.04 0.1

0.10 0.3

236 774

754 822 881

3300 4910

SPM2KV(HD)-1111

026023M

1111 563.0

.120 3.1

1.595 40.5

0.04 0.1

0.10 0.3

257 843

942 1025 1098

4500 6696

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

66

www.DrakaMOG.com

Bostrig Type P
0807
Page 25 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV & 2000V


Single conductor / unarmored

TYPE P POWER CABLE


600V or 0.6/1kV & 2000V
18 AWG to 1111 MCM
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J104

Construction
1. Conductor
2. Insulation

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001). Thickeness
as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight,
mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600 & 2000V / IEC standards
for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245
and IEEE 45 (1998) for 600V & 2000V.

67

www.DrakaMOG.com

Bostrig Type P
0807
Page 26 of 62

BOSTRIG TYPE P POWER CABLE


single conductor / unarmored
18 AWG to 1111 MCM / 600V or 0.6/1kV & 2000V
600V or 600/1000V
Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

SP-18

026000

18

.030 0.76

.111 2.8

6.4 21.0

0.18 0.6

58 190

16 16 17

11 16

SP-16

026001

16

.030 0.76

.119 3.0

4.5 14.8

0.18 0.6

65 213

20 23 25

13 19

SP-14

026002

14

.030 0.76

.133 3.4

2.9 9.5

0.16 0.5

77 253

29 37 39

18 27

SP-12

026004

12

.030 0.76

.151 3.8

1.9 6.2

0.15 0.5

90 295

38 45 49

28 42

SP-10

026004

10

.030 0.76

.180 4.6

1.2 3.9

0.14 0.5

107 351

51 58 61

44 65

SP-8

026005

8 8.4

.045 1.1

.233 5.9

0.7 2.3

0.14 0.5

95 311

67 72 77

69 103

SP-6

026006

6 13.3

.045 1.1

.290 7.4

0.5 1.6

0.12 0.4

126 413

90 96 103

103 153

SP-5

026007

5 18.6

.045 1.1

.335 8.5

0.3 1.6

0.12 0.4

140 459

111 109 117

145 216

SP-4

026008

4 21.5

.045 1.11

.353 9.0

0.3 1.6

0.12 0.4

153 502

122 128 137

171 254

SP-3

026009

3 27.2

.045 1.1

.380 9.7

0.2 0.7

0.11 0.4

173 567

142 146 156

200 298

SP-2

026010

2 33.7

.045 1.1

.423 10.7

0.2 0.7

0.11 0.4

187 613

162 169 181

231 344

SP-1

026011

1 46.1

.055 1.4

.493 12.5

0.1 0.3

0.11 0.4

178 584

197 194 208

348 518

SP-1/0

026012

1/0 56.3

.055 1.4

.524 13.3

0.1 0.3

0.11 0.4

190 623

223 227 243

414 618

SP-2/0

026013

2/0 67.6

.055 1.4

.578 14.7

0.09 0.3

0.10 0.3

212 695

250 262 281

476 708

SP-3/0

026014

3/0 92.1

.055 1.4

.659 16.7

0.08 0.3

0.10 0.3

245 804

304 300 321

671 999

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

SP2KV-8

030477

0.055 1.40

0.265 6.7

0.695 2.28

0.108 0.354

82 269

67 72 77

74 111

SP2KV-6

030478

0.055 1.40

0.326 8.3

0.442 1.45

0.099 0.324

108 354

90 96 103

110 164

SP2KV-5

030479

0.055 1.40

0.354 9.0

0.332 1.09

0.097 0.318

120 393

111 109 117

147 220

SP2KV-4

030480

0.055 1.40

0.38 9.7

0.277 0.91

0.095 0.312

131 430

122 128 137

170 254

SP2KV-3

030481

0.055 1.40

0.42 10.7

0.221 0.72

0.092 0.302

148 485

142 146 156

206 307

SP2KV-2

030482

0.055 1.40

0.449 11.4

0.176 0.58

0.090 0.295

160 525

162 169 181

251 374

SP2KV-1

030483

0.065 1.65

0.519 13.2

0.141 0.46

0.091 0.298

158 518

197 194 208

341 507

SP2KV-1/0

029732

1/0

0.065 1.65

0.549 13.9

0.113 0.37

0.089 0.292

168 551

223 227 243

405 603

SP2KV-2/0

027055

2/0

0.065 1.65

0.594 15.1

0.092 0.30

0.088 0.289

184 604

250 262 281

499 742

SP2KV-3/0

030484

3/0

0.065 1.65

0.684 17.4

0.075 0.25

0.086 0.282

216 708

304 300 321

668 994

SP2KV(HD)-4/0

026015

4/0 112.6

0.105 2.7

.821 20.9

0.07 0.2

0.11 0.4

146 479

344 351 376

896 1333

SP2KV(HD)-262

026016

262 133.1

0.105 2.7

.895 22.7

0.06 0.2

0.10 0.3

162 531

382 407 436

1035 1540

SP2KV(HD)-313

026017

313 158.7

0.105 2.7

.966 24.5

0.06 0.2

0.10 0.3

175 574

426 455 487

1227 1826

SP2KV(HD)-373

026018

373 189.2

0.105 2.7

1.033 26.2

0.05 0.2

0.10 0.3

189 620

476 516 553

1424 2119

SP2KV(HD)-444

026019

444 225.2

0.105 2.7

1.114 28.3

0.05 0.2

0.10 0.3

205 672

531 588 630

1707 2540

SP2KV(HD)-535

026020

535 271.3

0.120 3.1

1.227 31.2

0.04 0.1

0.10 0.3

200 656

596 630 675

2025 3014

SP2KV(HD)-646

026021

646 327.5

0.120 3.1

1.331 33.3

0.04 0.1

0.10 0.3

216 708

670 731 783

2429 3615

SP2KV(HD)-777

026022

777 394.2

0.120 3.1

1.424 36.2

0.04 0.1

0.10 0.3

236 774

754 822 881

2896 4310

SP2KV(HD)-1111

026023

1111 563.0

0.120 3.1

1.675 42.5

0.04 0.1

0.10 0.3

257 843

942 1025 1098

3946 5872

Type
Designation

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

2000V
Impedance
(Phase-Neutral)
/kft - /km

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

68

www.DrakaMOG.com

Bostrig Type P
0807
Page 1 of 62

BOSTRIG TYPE P POWER CABLE 600V, 0.6/1kV & 2000V


Single conductor / armored and sheathed

TYPE P POWER CABLE


600V or 0.6/1kV & 2000V
8 AWG to 1111 MCM
2

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J104

This product is readily available in an unarmored version.

Construction
1. Conductor
2. Insulation
3. Armor
4. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight,
mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600 & 2000V / IEC standards
for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245
and IEEE 45 (1998) for 600V & 2000V.

69

www.DrakaMOG.com

Bostrig Type P
0807
Page 2 of 62

BOSTRIG TYPE P POWER CABLE


single conductor / armored and sheathed
8 AWG to 1111 MCM / 600V or 0.6/1kV & 2000V
600V
Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

026024

8 8.4

.060 1.5

.415 10.5

0.7 2.3

0.14 0.5

95 311

67 72 77

155 231

026025

6 13.3

.060 1.5

.470 11.9

0.5 1.6

0.12 0.4

126 413

90 96 103

210 313

SPBS-5

026026

5 18.6

.060 1.5

.525 13.3

0.3 1.6

0.12 0.4

140 459

111 109 117

260 387

SPBS-4

026027

4 21.5

.060 1.5

.535 13.6

0.3 1.6

0.12 0.4

153 502

122 128 137

295 439

SPBS-3

026028

3 27.2

.060 1.5

.560 14.2

0.2 0.7

0.11 0.4

173 567

142 146 156

335 499

SPBS-2

026029

2 33.7

.060 1.5

.595 15.1

0.2 0.7

0.11 0.4

187 613

162 169 181

380 566

SPBS-1

026030

1 46.1

.060 1.5

.675 17.2

0.1 0.3

0.11 0.4

178 584

197 194 208

520 774

SPBS-1/0

026031

1/0 56.3

.060 1.5

.730 18.5

0.1 0.3

0.11 0.4

190 623

223 227 243

615 915

SPBS-2/0

026032

2/0 67.6

.060 1.5

.745 18.9

0.09 0.3

0.10 0.3

212 695

250 262 281

680 1012

SPBS-3/0

026033

3/0 92.1

.080 2.0

.890 22.6

0.08 0.3

0.10 0.3

245 804

304 300 321

940 1399

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

SPBS2KV-8

036754

0.045 1.14

0.43 10.9

0.696 2.28

0.138 0.453

82 269

67 72 77

157 234

SPBS2KV-6

036755

0.045 1.14

0.491 12.5

0.442 1.45

0.124 0.407

108 354

90 96 103

208 310

SPBS2KV-5

036756

0.045 1.14

0.519 13.2

0.333 1.09

0.120 0.394

120 393

111 109 117

253 376

SPBS2KV-4

036757

0.060 1.52

0.575 14.6

0.279 0.92

0.120 0.394

131 430

122 128 137

299 445

SPBS2KV-3

036758

0.060 1.52

0.615 15.6

0.222 0.73

0.115 0.377

148 485

142 146 156

346 515

SPBS2KV-2

036742

0.060 1.52

0.644 16.4

0.178 0.58

0.112 0.367

160 525

162 169 181

399 594

SPBS2KV-1

036759

0.060 1.52

0.714 18.1

0.143 0.47

0.110 0.361

158 518

197 194 208

509 757

SPBS2KV-1/0

036760

1/0

0.060 1.52

0.744 18.9

0.115 0.38

0.108 0.354

168 551

223 227 243

581 865

SPBS2KV-2/0

036761

2/0

0.060 1.52

0.789 20.0

0.095 0.31

0.105 0.344

184 604

250 262 281

688 1024

Draka
Number

SPBS-8
SPBS-6

Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Conductor Size
AWG/MCM mm2

Type
Designation

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

2000V
Impedance
(Phase-Neutral)
/kft - /km

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

SPBS2KV-3/0

027068

3/0

0.080 2.03

0.939 23.8

0.079 0.26

0.105 0.344

216 708

304 300 321

937 1395

SPBS2KV(HD)-4/0

026034

4/0 112.6

.080 2.0

1.040 26.4

0.07 0.2

0.11 0.4

146 479

344 351 376

1195 1778

SPBS2KV(HD)-262

026035

262 133.1

.080 2.0

1.090 27.7

0.06 0.2

0.10 0.3

162 531

382 407 436

1350 2009

SPBS2KV(HD)-313

026036

313 158.7

.080 2.0

1.155 29.3

0.06 0.2

0.10 0.3

175 574

426 455 487

1550 2307

SPBS2KV(HD)-373

026037

373 189.2

.080 2.0

1.225 31.1

0.05 0.2

0.10 0.3

189 620

476 516 553

1785 2656

SPBS2KV(HD)-444

026038

444 225.2

.080 2.0

1.295 32.9

0.05 0.2

0.10 0.3

205 672

531 588 630

2065 3073

SPBS2KV(HD)-535

026039

535 271.3

.110 2.8

1.475 37.5

0.04 0.1

0.10 0.3

200 656

596 630 675

2540 3780

SPBS2KV(HD)-646

026040

646 327.5

.110 2.8

1.575 40.0

0.04 0.1

0.10 0.3

216 708

670 731 783

2950 4390

SPBS2KV(HD)-777

026041

777 394.2

.110 2.8

1.665 42.3

0.04 0.1

0.10 0.3

236 774

754 822 881

3450 5134

SPBS2KV(HD)-1111 026042

1111 563.0

.125 3.2

1.990 48.3

0.04 0.1

0.10 0.3

257 843

942 1025 1098

4700 6994

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

70

www.DrakaMOG.com

Bostrig Type P
0807
Page 27 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Two conductor / unarmored

TYPE P POWER CABLE


600V or 0.6/1kV
8 AWG to 777 MCM
1

Applications

Approvals

BostrigTM Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

This product is readily available in an armored and


sheathed version.

Transport Canada Approved AMS400-20-2

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)

Manufactured to BIW Specifying Standard J105

CONSTRUCTION
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600 & 2000V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V & 2000V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

71

www.DrakaMOG.com

Bostrig Type P
0807
Page 28 of 62

BOSTRIG TYPE P POWER CABLE


two conductor / unarmored
8 AWG to 777 MCM / 600V or 0.6/1kV
Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Draka
Number

Conductor Size
AWG/MCM mm2

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

DPN-8

026043

8 7.57

.060 1.5

.590 15.0

0.70 2.3

0.12 0.4

95 312

58 64 69

210 313

DPN-6

026044

6 12.5

.060 1.5

.705 17.9

0.46 1.5

0.11 0.4

126 413

83 85 91

315 469

DPN-5

026045

5 18.6

.060 1.5

.810 20.6

0.33 1.1

0.11 0.4

140 459

95 101 108

440 655

DPN-4

026046

4 21.5

.080 2.0

.870 22.1

0.29 1.0

0.10 0.3

153 502

104 110 118

520 774

DPN-3

026047

3 25.6

.080 2.0

.920 23.4

0.23 0.8

0.10 0.3

173 567

121 132 141

605 900

DPN-2

026048

2 30.7

.080 2.0

.985 25.0

0.18 0.6

0.10 0.3

187 613

138 149 160

685 1019

DPN-1

026049

1 46.0

.080 2.0

1.150 29.2

0.14 0.5

0.09 0.3

178 584

168 174 186

975 1451

DPN-1/0

026050

1/0 56.3

.080 2.0

1.260 32.0

0.12 0.4

0.09 0.3

190 623

190 199 213

1150 1711

DPN-2/0

026051

2/0 66.5

.080 2.0

1.320 33.5

0.09 0.3

0.09 0.3

212 695

213 242 259

1285 1912

DPN-3/0

026052

3/0 92.1

.110 2.8

1.560 39.6

0.08 0.3

0.09 0.3

245 804

259 265 284

1860 2768

DPN-4/0

026053

4/0 112.6

.110 2.8

1.660 42.2

0.07 0.2

0.09 0.3

259 850

293 307 329

2215 3296

DPN-262

026054

262 133.0

.125 3.2

1.830 46.5

0.06 0.2

0.09 0.3

247 810

325 358 383

2605 3877

DPN-313

026055

313 158.6

.125 3.2

1.965 49.9

0.05 0.2

0.09 0.3

270 886

362 391 419

3035 4517

DPN-373

026056

373 189.3

.125 3.2

2.105 53.5

0.04 0.1

0.09 0.3

292 958

405 442 473

3615 5380

DPN-444

026057

444 225.1

.125 3.2

2.245 57.0

0.04 0.1

0.09 0.3

318 1043

451 504 540

4140 6161

DPN-535

026058

535 271.2

.140 3.6

2.4905 63.4

0.04 0.1

0.09 0.3

291 954

507 538 576

4960 7381

DPN-646

026059

646 327.5

.140 3.6

2.695 68.5

0.04 0.1

0.09 0.3

314 1030

570 632 677

5880 8750

DPN-777

026060

777 393.8

.140 3.6

2.900 73.7

0.03 0.1

0.09 0.3

345 1132

641 684 733

7030 10462

Type
Designation

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

72

www.DrakaMOG.com

Bostrig Type P
0807
Page 3 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Two conductor / armored and sheathed

TYPE P POWER CABLE


600V or 0.6/1kV
1

8 AWG to 777 MCM

Applications

Approvals

BostrigTM Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

Transport Canada Approved AMS400-20-2


Manufactured to BIW Specifying Standard J104

This product is readily available in an unarmored version.

CONSTRUCTION
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

73

www.DrakaMOG.com

Bostrig Type P
0807
Page 4 of 62

BOSTRIG TYPE P POWER CABLE


two conductor / armored and sheathed
8 AWG to 777 MCM / 600V or 0.6/1kV
Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

DPNBS-8

026108

8 7.57

.060 1.5

.765 19.4

0.70 2.3

0.12 0.4

95 312

58 64 69

405 603

DPNBS-6

026109

6 12.5

.080 2.0

.920 23.4

0.46 1.5

0.11 0.4

126 413

83 85 91

580 863

DPNBS-5

026110

5 18.6

.080 2.0

1.040 26.4

0.33 1.1

0.11 0.4

140 459

95 101 108

720 1071

DPNBS-4

026111

4 21.5

.080 2.0

1.090 27.7

0.29 1.0

0.10 0.3

153 502

104 110 118

850 1265

DPNBS-3

026112

3 25.6

.080 2.0

1.140 29.0

0.23 0.8

0.10 0.3

173 567

121 132 141

940 1399

DPNBS-2

026113

2 30.7

.080 2.0

1.205 30.6

0.18 0.6

0.10 0.3

187 613

138 149 160

1045 1555

DPNBS-1

026114

1 46.0

.110 2.8

1.430 36.3

0.14 0.5

0.09 0.3

178 584

168 174 186

1480 2202

DPNBS-1/0

026115

1/0 56.3

.110 2.8

1.535 39.0

0.12 0.4

0.09 0.3

190 623

190 199 213

1695 2522

DPNBS-2/0

026116

2/0 66.5

.110 2.8

1.600 40.6

0.09 0.3

0.09 0.3

212 695

213 242 259

1845 2746

DPNBS-3/0

026117

3/0 92.1

.125 3.2

1.870 47.5

0.08 0.3

0.09 0.3

245 804

259 265 284

2585 3825

DPNBS-4/0

026118

4/0 112.6

.125 3.2

1.975 50.2

0.07 0.2

0.09 0.3

259 850

293 307 329

2980 4435

DPNBS-262

026119

262 133.0

.125 3.2

2.145 54.5

0.06 0.2

0.09 0.3

247 810

325 358 383

3445 5127

DPNBS-313

026120

313 158.6

.140 3.6

2.305 58.6

0.05 0.2

0.09 0.3

270 886

362 391 419

4005 5960

DPNBS-373

026121

373 189.3

.140 3.6

2.445 62.1

0.04 0.1

0.09 0.3

292 958

405 442 473

4650 6920

DPNBS-444

026122

444 225.1

.140 3.6

2.585 65.7

0.04 0.1

0.09 0.3

318 1043

451 504 540

5240 7798

DPNBS-535

026123

535 271.2

.155 3.9

2.865 72.8

0.04 0.1

0.09 0.3

291 954

507 538 576

6175 9189

DPNBS-646

026124

646 327.5

.155 3.9

3.065 77.9

0.04 0.1

0.09 0.3

314 1030

570 632 677

7185 10692

DPNBS-777

026125

777 393.8

.155 3.9

3.270 83.01

0.03 0.1

0.09 0.3

345 1132

641 684 733

8420 12530

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

74

www.DrakaMOG.com

Bostrig Type P
0807
Page 29 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Three conductor / unarmored

TYPE P POWER CABLE


600V or 0.6/1kV
8 AWG to 777 MCM
1

Approvals

Applications
BostrigTM Type P Marine and Offshore Cable is
primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.
Bostrig cables have excellent resistance to oil, abrasion,
moisture, sunlight and ester-based mud (Type P-MR).
The standard insulation has a continuous operating
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an armored and
sheathed version.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Det Norske Veritas Type Approval Certificates E8792,
E8793, E8794, E8795 and E8796.
American Bureau of Shipping Approval Certificate
03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

75

www.DrakaMOG.com

Bostrig Type P
0807
Page 30 of 62

BOSTRIG TYPE P POWER CABLE


three conductor / unarmored
8 AWG to 777 MCM / 600V or 0.6/1kV
Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Draka
Number

Conductor Size
AWG/MCM mm2

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

TPN-8

026061

8 7.57

.060 1.5

.625 15.9

0.70 2.3

0.12 0.4

95 312

47 52 56

275 409

TPN-6

026062

6 12.5

.060 1.5

.750 19.1

0.46 1.5

0.11 0.4

126 413

63 70 75

420 625

TPN-5

026063

5 18.6

.080 2.0

.890 22.6

0.33 1.1

0.11 0.4

140 459

78 82 88

555 826

TPN-4

026064

4 21.5

.080 2.0

.925 23.5

0.29 1.0

0.10 0.3

153 502

86 92 99

695 1034

TPN-3

026065

3 25.6

.080 2.0

.975 24.8

0.23 0.8

0.10 0.3

173 567

99 108 116

805 1198

TPN-2

026066

2 30.7

.080 2.0

1.045 26.5

0.18 0.6

0.10 0.3

187 613

111 122 131

915 1362

TPN-1

026067

1 46.1

.080 2.0

1.225 31.1

0.14 0.5

0.09 0.3

178 584

137 143 153

1320 1964

TPN-1/0

026068

1/0 56.3

.080 2.0

1.340 34.0

0.12 0.4

0.09 0.3

190 623

156 164 176

1610 2395

TPN-2/0

026069

2/0 66.5

.110 2.8

1.440 36.6

0.09 0.3

0.09 0.3

212 695

175 188 201

1885 2805

TPN-3/0

026070

3/0 92.1

.110 2.8

1.665 42.3

0.08 0.3

0.09 0.3

245 804

213 218 234

2560 3810

TPN-4/0

026071

4/0 112.6

.125 3.2

1.800 45.7

0.07 0.2

0.09 0.3

259 850

241 252 270

3060 4555

TPN-262

026072

262 133.0

.125 3.2

1.950 49.5

0.06 0.2

0.09 0.3

247 810

267 294 315

3555 5290

TPN-313

026073

313 158.6

.125 3.2

2.095 53.2

0.05 0.2

0.09 0.3

270 886

298 321 344

4140 6161

TPN-373

026074

373 189.3

.125 3.2

2.245 57.0

0.04 0.1

0.09 0.3

292 958

333 361 387

4880 7262

TPN-444

026075

444 225.1

.140 3.6

2.425 61.6

0.04 0.1

0.09 0.3

318 1043

371 411 440

5800 8631

TPN-535

026076

535 271.2

.140 3.6

2.660 67.6

0.04 0.1

0.09 0.3

291 954

417 443 475

6945 10335

TPN-646

026077

646 327.5

.140 3.6

2.905 73.8

0.04 0.1

0.09 0.3

314 1030

469 516 553

8185 12818

TPN-777

026078

777 393.8

.140 3.6

3.095 78.6

0.03 0.1

0.09 0.3

345 1132

528 562 602

9695 14428

Type
Designation

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

76

www.DrakaMOG.com

Bostrig Type P
0807
Page 5 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Three conductor / armored and sheathed

TYPE P POWER CABLE


600V or 0.6/1kV
8 AWG to 777 MCM
1

Approvals

Applications
BostrigTM Type P Marine and Offshore Cable is
primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.
Bostrig cables have excellent resistance to oil, abrasion,
moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.
The standard insulation has a continuous operating
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Det Norske Veritas Type Approval Certificates E8792,
E8793, E8794, E8795 and E8796.
American Bureau of Shipping Approval Certificate
03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998)
for 600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

77

www.DrakaMOG.com

Bostrig Type P
0807
Page 6 of 62

BOSTRIG TYPE P POWER CABLE


three conductor / armored and sheathed
8 AWG to 777 MCM / 600V or 0.6/1kV
Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

TPNBS-8

026126

8 7.57

.060 1.5

.835 21.2

0.70 2.3

0.12 0.4

95 312

47 52 56

480 714

TPNBS-6

026127

6 12.5

.080 2.0

.965 24.5

0.46 1.5

0.11 0.4

126 413

63 70 75

700 1042

TPNBS-5

026128

5 18.6

.080 2.0

1.120 28.5

0.33 1.1

0.11 0.4

140 459

78 82 88

900 1339

TPNBS-4

026129

4 21.5

.080 2.0

1.140 29.0

0.29 1.0

0.10 0.3

153 502

86 92 99

1040 1548

TPNBS-3

026130

3 25.6

.080 2.0

1.200 30.5

0.23 0.8

0.10 0.3

173 567

99 108 116

1160 1726

TPNBS-2

026131

2 30.7

.080 2.0

1.265 32.1

0.18 0.6

0.10 0.3

187 613

111 122 131

1295 1927

TPNBS-1

026132

1 46.1

.110 2.8

1.505 38.2

0.14 0.5

0.09 0.3

178 584

137 143 153

1850 2753

TPNBS-1/0

026133

1/0 56.3

.110 2.8

1.620 41.2

0.12 0.4

0.09 0.3

190 623

156 164 176

2190 3259

TPNBS-2/0

026134

2/0 66.5

.110 2.8

1.730 43.9

0.09 0.3

0.09 0.3

212 695

175 188 201

2500 3720

TPNBS-3/0

026135

3/0 92.1

.125 3.2

1.975 50.2

0.08 0.3

0.09 0.3

245 804

213 218 234

3330 4955

TPNBS-4/0

026136

4/0 112.6

.125 3.2

2.110 53.6

0.07 0.2

0.09 0.3

259 850

241 252 270

3890 5789

TPNBS-262

026137

262 133.0

.125 3.2

2.290 58.2

0.06 0.2

0.09 0.3

247 810

267 294 315

4515 6704

TPNBS-313

026138

313 158.6

.140 3.6

2.435 61.9

0.05 0.2

0.09 0.3

270 886

298 321 344

5170 7694

TPNBS-373

026139

373 189.3

.140 3.6

2.585 65.7

0.04 0.1

0.09 0.3

292 958

333 361 387

5975 8892

TPNBS-444

026140

444 225.1

.140 3.6

2.765 70.2

0.04 0.1

0.09 0.3

318 1043

371 411 440

6980 10387

TPNBS-535

026141

535 271.2

.140 3.6

3.030 77.0

0.04 0.1

0.09 0.3

291 954

417 443 475

8235 12255

TPNBS-646

026142

646 327.5

.140 3.6

3.275 83.2

0.04 0.1

0.09 0.3

314 1030

469 516 553

9575 14249

TPNBS-777

026143

777 393.8

.140 3.6

3.465 88.0

0.03 0.1

0.09 0.3

345 1132

528 562 602

11280 16786

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

78

www.DrakaMOG.com

Bostrig Type P
0807
Page 31 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Four conductor / unarmored

TYPE P POWER CABLE


600V or 0.6/1kV
8 AWG to 777 MCM
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

79

www.DrakaMOG.com

Bostrig Type P
0807
Page 32 of 62

BOSTRIG TYPE P POWER CABLE


four conductor / unarmored
8 AWG to 777 MCM / 600V or 0.6/1kV
Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Draka
Number

Conductor Size
AWG/MCM mm2

Jacket
Thickness
in mm

Cable Diameter
(nominal)
in mm

FPN-8

026079

8 7.57

.060 1.5

.690 17.5

0.70 2.3

0.12 0.4

95 312

47 52 56

350 521

FPN-6

026080

6 12.5

.060 1.5

.820 20.8

0.46 1.5

0.11 0.4

126 413

63 70 75

540 804

FPN-5

026081

5 18.6

.080 2.0

.980 24.9

0.33 1.1

0.11 0.4

140 459

78 82 88

775 1153

FPN-4

026082

4 21.5

.080 2.0

1.020 25.9

0.29 1.0

0.10 0.3

153 502

86 92 99

885 1317

FPN-3

026083

3 25.6

.080 2.0

1.080 27.4

0.23 0.8

0.10 0.3

173 567

99 108 116

1025 1525

FPN-2

026084

2 30.7

.080 2.0

1.160 29.5

0.18 0.6

0.10 0.3

187 613

111 122 131

1170 1741

FPN-1

026085

1 46.1

.080 2.0

1.360 34.5

0.14 0.5

0.09 0.3

178 584

137 143 153

1710 2545

FPN-1/0

026086

1/0 56.3

.110 2.8

1.510 38.4

0.12 0.4

0.09 0.3

190 623

156 164 176

2100 3125

FPN-2/0

026087

2/0 66.5

.110 2.8

1.590 40.4

0.09 0.3

0.09 0.3

212 695

175 188 201

2410 3586

FPN-3/0

026088

3/0 92.1

.125 3.2

1.875 47.6

0.08 0.3

0.09 0.3

245 804

213 218 234

3360 5000

FPN-4/0

026089

4/0 112.6

.125 3.2

1.995 50.7

0.07 0.2

0.09 0.3

259 850

241 252 270

3940 5863

FPN-262

026090

262 133.0

.125 3.2

2.165 55.0

0.06 0.2

0.09 0.3

247 810

267 294 315

4640 6905

FPN-313

026091

313 158.6

.140 3.6

2.355 59.8

0.05 0.2

0.09 0.3

270 886

298 321 344

5475 8148

FPN-373

026092

373 189.3

.140 3.6

2.525 64.1

0.04 0.1

0.09 0.3

292 958

333 361 387

6365 9472

FPN-444

026093

444 225.1

.140 3.6

2.695 68.5

0.04 0.1

0.09 0.3

318 1043

371 411 440

7500 11161

FPN-535

026094

535 271.2

.140 3.6

2.990 76.0

0.04 0.1

0.09 0.3

291 954

417 443 475

8970 13349

FPN-646

026095

646 327.5

.140 3.6

3.230 82.0

0.04 0.1

0.09 0.3

314 1030

469 516 553

10640 15834

FPN-777

026096

777 393.8

.140 3.6

3.445 87.5

0.03 0.1

0.09 0.3

345 1132

528 562 602

12730 18944

Type
Designation

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.
The ampacity of 4 conductor cables is based on three current carrying conductors and the fourth conductor being used as a Neutral or Grounding conductor. If all conductors are
current carrying, the ampacity must be reduced by 0.8.

80

www.DrakaMOG.com

Bostrig Type P
0807
Page 7 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Four conductor / armored and sheathed

TYPE P POWER CABLE


600V or 0.6/1kV
8 AWG to 777 MCM
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables complywith the Crush and Impact requirements of
UL 2225.

81

www.DrakaMOG.com

Bostrig Type P
0807
Page 8 of 62

BOSTRIG TYPE P POWER CABLE


four conductor / armored and sheathed
8 AWG to 777 MCM / 600V or 0.6/1kV
Cable Diameter
(nominal)
in mm

Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

FPNBS-8

026144

8 7.57

.060 1.5

.910 23.1

0.70 2.3

0.13 0.4

95 312

47 52 56

605 900

FPNBS-6

026145

6 12.5

.080 2.0

1.045 26.5

0.46 1.5

0.12 0.4

126 413

63 70 75

890 1324

FPNBS-5

026146

5 18.6

.080 2.0

1.210 30.7

0.33 1.1

0.11 0.4

140 459

78 82 88

1140 1696

FPNBS-4

026147

4 21.5

.080 2.0

1.240 31.5

0.29 1.0

0.11 0.4

153 502

86 92 99

1265 1883

FPNBS-3

026148

3 25.6

.080 2.0

1.300 33.0

0.23 0.8

0.11 0.4

173 567

99 108 116

1415 2106

FPNBS-2

026149

2 30.7

.080 2.0

1.440 36.6

0.18 0.6

0.10 0.3

187 613

111 122 131

1675 2493

FPNBS-1

026150

1 46.1

.110 2.8

1.640 41.7

0.14 0.5

0.10 0.3

178 584

137 143 153

2300 3423

FPNBS-1/0

026151

1/0 56.3

.110 2.8

1.820 46.2

0.12 0.4

0.10 0.3

190 623

156 164 176

2860 4256

FPNBS-2/0

026152

2/0 66.5

.110 2.8

1.920 48.8

0.09 0.3

0.10 0.3

212 695

175 188 201

3150 4688

FPNBS-3/0

026153

3/0 92.1

.125 3.2

2.185 55.5

0.08 0.3

0.10 0.3

245 804

213 218 234

4220 6280

FPNBS-4/0

026154

4/0 112.6

.125 3.2

2.335 59.3

0.07 0.2

0.09 0.3

259 850

241 252 270

4920 7322

FPNBS-262

026155

262 133.0

.125 3.2

2.505 63.6

0.06 0.2

0.09 0.3

247 810

267 294 315

5700 8483

FPNBS-313

026156

313 158.6

.140 3.6

2.695 68.5

0.05 0.2

0.09 0.3

270 886

298 321 344

6620 9852

FPNBS-373

026157

373 189.3

.140 3.6

2.895 73.5

0.04 0.1

0.09 0.3

292 958

333 361 387

7590 11295

FPNBS-444

026158

444 225.1

.140 3.6

3.065 77.9

0.04 0.1

0.09 0.3

318 1043

371 411 440

8800 13096

FPNBS-535

026159

535 271.2

.140 3.6

3.360 85.3

0.04 0.1

0.09 0.3

291 954

417 443 475

10500 15626

FPNBS-646

026160

646 327.5

.140 3.6

3.600 91.4

0.04 0.1

0.09 0.3

314 1030

469 516 553

12290 18290

FPNBS-777

026161

777 393.8

.140 3.6

3.815 96.9

0.04 0.1

0.09 0.3

345 1132

528 562 602

14500 21578

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.
The ampacity of 4 conductor cables is based on three current carrying conductors and the fourth conductor being used as a Neutral or Grounding conductor. If all conductors are
current carrying, the ampacity must be reduced by 0.8.

82

www.DrakaMOG.com

Bostrig Type P
0807
Page 33 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Five conductor / armored and sheathed

TYPE P POWER CABLE


600V or 0.6/1kV
8 to 4/0 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates


No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

83

www.DrakaMOG.com

Bostrig Type P
0807
Page 34 of 62

BOSTRIG TYPE P POWER CABLE


five conductor / unarmored
8 to 4/0 AWG / 600V or 0.6/1kV
Cable Diameter
(nominal)
in mm

Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Draka
Number

Conductor Size
AWG/MCM mm2

Jacket
Thickness
in mm

QPN-8

026097

8 7.57

.060 1.5

760 19.3

0.70 2.3

0.12 0.4

95 312

38 42 45

430 640

QPN-6

026098

6 12.5

.080 2.0

.955 24.3

0.46 1.5

0.11 0.4

126 413

50 56 60

700 1042

QPN-5

026099

5 18.6

.080 2.0

1.080 27.4

0.33 1.1

0.11 0.4

140 459

62 66 70

950 1414

QPN-4

026100

4 21.5

.080 2.0

1.125 28.6

0.29 1.0

0.10 0.3

153 502

69 74 79

1100 1637

QPN-3

026101

3 25.6

.110 2.8

1.195 30.4

0.23 0.8

0.10 0.3

173 567

79 86 93

1260 1875

QPN-2

026102

2 30.7

.110 2.8

1.280 32.5

0.18 0.6

0.10 0.3

187 613

89 98 105

1450 2158

QPN-1

026103

1 46.1

.125 3.2

1.565 39.8

0.14 0.5

0.09 0.3

178 584

110 114 122

2205 3282

QPN-1/0

026104

1/0 56.3

.125 3.2

1.715 43.6

0.12 0.4

0.09 0.3

190 623

125 131 141

2650 3945

QPN-2/0

026105

2/0 66.5

.125 3.2

1.790 45.5

0.09 0.3

0.09 0.3

212 695

140 150 161

3015 4487

QPN-3/0

026106

3/0 92.1

.140 3.6

2.075 52.7

0.08 0.3

0.09 0.3

245 804

170 174 187

4140 6161

QPN-4/0

026107

4/0 112.6

.140 3.6

2.210 56.1

0.07 0.2

0.09 0.3

259 850

193 202 216

4850 7218

Type
Designation

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

84

www.DrakaMOG.com

Bostrig Type P
0807
Page 9 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Five conductor / armored and sheathed

TYPE P POWER CABLE


600V or 0.6/1kV
8 to 4/0 AWG
1

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J105

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Jacket
4. Armor
5. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

85

www.DrakaMOG.com

Bostrig Type P
0807
Page 10 of 62

BOSTRIG TYPE P POWER CABLE


five conductor / armored and sheathed
8 to 4/0 AWG / 600V or 0.6/1kV
Cable Diameter
(nominal)
in mm

Impedance
(Phase-Neutral)
/kft - /km

Calculated Ampacity
Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

Sheath
Thickness
in mm

QPNBS-8

026162

8 7.57

.080 2.0

.980 24.9

0.70 2.3

0.13 0.4

95 312

38 42 45

710 1057

QPNBS-6

026163

6 12.5

.080 2.0

1.175 29.9

0.46 1.5

0.12 0.4

126 413

50 56 60

1045 1555

QPNBS-5

026164

5 18.6

.080 2.0

1.310 33.2

0.33 1.1

0.11 0.4

140 459

62 66 70

1350 2009

QPNBS-4

026165

4 21.5

.080 2.0

1.345 34.2

0.29 1.0

0.11 0.4

153 502

69 74 79

1510 2247

QPNBS-3

026166

3 25.6

.110 2.8

1.475 37.5

0.23 0.8

0.11 0.4

173 567

79 86 93

1775 2642

QPNBS-2

026167

2 30.7

.110 2.8

1.560 39.6

0.18 0.6

0.10 0.3

187 613

89 98 105

2000 2976

QPNBS-1

026168

1 46.1

.125 3.2

1.875 47.6

0.14 0.5

0.10 0.3

178 584

110 114 122

2930 4360

QPNBS-1/0

026169

1/0 56.3

.125 3.2

2.025 51.4

0.12 0.4

0.10 0.3

190 623

125 131 141

3435 5112

QPNBS-2/0

026170

2/0 66.5

.125 3.2

2.120 53.9

0.09 0.3

0.10 0.3

212 695

140 150 161

3830 5700

QPNBS-3/0

026171

3/0 92.1

.140 3.6

2.415 61.3

0.08 0.3

0.10 0.3

245 804

170 174 187

5150 7664

QPNBS-4/0

026172

4/0 112.6

.140 3.6

2.550 64.8

0.07 0.2

0.09 0.3

259 850

193 202 216

5930 8825

Inductance
Capacitance
mH/kft mH/km pF/ft pF/m

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

86

www.DrakaMOG.com

Bostrig Type P
0807
Page 51 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V


Overall shielded multiconductor /
armored and sheathed

TYPE P SIGNAL CABLE


600V
1

20, 18 & 16 AWG

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an unarmored version.

Lloyds Registry of Shipping Approval Certificates No.


95/00161 (E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured tc BIW Specifying Standard J106

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket
5 Armor
6. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over the cabled core.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight,
mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for
0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245
and IEEE 45 (1998) for 600V.

87

www.DrakaMOG.com

Bostrig Type P
0807
Page 52 of 62

BOSTRIG TYPE P SIGNAL CABLE


overall shielded multiconductor / armored and sheathed
20, 18 & 16 AWG / 600V
20 AWG 0.61 mm2
Draka
Number

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

C(0S)20PNBS-3

026503

19/32

.030 0.76

.060 1.5

.533 13.5

185 275

C(0S)20PNBS-4

026504

19/32

.030 0.76

.060 1.5

.557 14.2

210 313

C(0S)20PNBS-5

026505

19/32

.030 0.76

.060 1.5

.586 14.8

230 342

C(0S)20PNBS-6

026506

19/32

.030 0.76

.060 1.5

.614 15.6

255 380

Draka
Number

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

C(0S)18PNBS-3

026507

19/30

.030 0.76

.060 1.5

.540 13.7

205 305

C(0S)18PNBS-4

026508

19/30

.030 0.76

.060 1.5

.569 14.5

231 344

C(0S)18PNBS-5

026509

19/30

.030 0.76

.060 1.5

.613 15.6

259 389

C(0S)18PNBS-6

026510

19/30

.030 0.76

.060 1.5

.345 16.4

286 426

25

19/30

.030 0.76

.060 1.5

1.074 27.3

705 1049

Draka
Number

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

C(0S)16PNBS-3

026511

19/29

.030 0.76

.060 1.5

.564 14.3

221 329

C(0S)16PNBS-4

026512

19/29

.030 0.76

.060 1.5

.584 14.8

242 360

C(0S)16PNBS-5

026513

19/29

.030 0.76

.060 1.5

.633 16.1

283 421

C(0S)16PNBS-6

026514

19/29

.030 0.76

.060 1.5

.666 16.9

313 466

12

19/29

.030 0.76

.060 1.5

.820 20.8

470 699

Type
Designation

18 AWG 0.96 mm2


Type
Designation

C(0S)18PNBS-25

16 AWG 1.23 mm2


Type
Designation

C(0S)16PNBS-12

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

88

www.DrakaMOG.com

Bostrig Type P
0807
Page 49 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V


Overall shielded multiconductor /
unarmored

TYPE P SIGNAL CABLE


600V
1

20, 18 & 16 AWG

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored version.

Lloyds Registry of Shipping Approval Certificates No.


95/00161 (E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured tc BIW Specifying Standard J106

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight,
mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for
0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245
and IEEE 45 (1998) for 600V & 2000V.

89

www.DrakaMOG.com

Bostrig Type P
0807
Page 50 of 62

BOSTRIG TYPE P SIGNAL CABLE


overall shielded multiconductor / unarmored
20, 18 & 16 AWG / 600V
20 AWG 0.61 mm2
Draka
Number

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

C(0S)20PN-3

026491

19/32

.030 0.76

.060 1.5

.345 8.8

65 97

C(0S)20PN-4

026492

19/32

.030 0.76

.060 1.5

.373 9.5

81 121

C(0S)20PN-5

026493

19/32

.030 0.76

.060 1.5

.403 10.2

92 137

C(0S)20PN-6

026494

19/32

.030 0.76

.060 1.5

.431 10.9

107 159

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km
78 116

Type
Designation

Cable Weight
(approximate)
Lbs/mft Kg/km

18 AWG 0.96 mm2


Type
Designation

Draka
Number

C(0S)18PN-3

19/30

.030 0.76

.060 1.5

.358 9.1

C(0S)18PN-4

026496

19/30

.030 0.76

.060 1.5

.385 9.8

92 137

C(0S)18PN-5

026497

19/30

.030 0.76

.060 1.5

.435 11.0

113 168

C(0S)18PN-6

026498

19/30

.030 0.76

.060 1.5

.467 11.9

130 193

25

19/30

.030 0.76

.060 1.5

.795 20.2

395 588

Draka
Number

Number of
Conductors

Stranding

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

C(0S)16PN-3

030645

19/29

.030 0.76

.060 1.5

.386 9.8

88 131

C(0S)16PN-4

026500

19/29

.030 0.76

.060 1.5

.400 10.2

104 155

C(0S)16PN-5

026501

19/29

.030 0.76

.060 1.5

.455 11.6

130 193

C(0S)16PN-6

026502

19/29

.030 0.76

.060 1.5

.488 12.4

150 223

C(0S)16PN-12

027052

12

19/29

.030 0.76

.060 1.5

.625 15.9

260 387

C(0S)18PN-25

16 AWG 1.23 mm2


Type
Designation

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

90

www.DrakaMOG.com

Bostrig Type P
0807
Page 45 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
unarmored

TYPE P SIGNAL CABLE


600V or 0.6/1kV
1

16 & 14 AWG

Applications

Approvals

BostrigTM Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

This product is readily available in an armored and


sheathed version.

Transport Canada Approved AMS400-20-2

Lloyds Registry of Shipping Approval Certificates No.


95/00161 (E3) and 95-00162(E3)

Manufactured tc BIW Specifying Standard J106

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

91

www.DrakaMOG.com

Bostrig Type P
0807
Page 46 of 62

BOSTRIG TYPE P SIGNAL CABLE


individual and overall shielded multipair / unarmored and sheathed
16 & 14 AWG / 600V or 0.6/1kV
16 AWG 1.23 mm2
Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Thickness
in mm

TP(0S)16PN-1

026364

.030 0.76

.060 1.5

.350 8.9

65 97

TP(I/S-0S)16PN-2

026365

.030 0.76

.060 1.5

.620 15.6

170 253

TP(I/S-0S)16PN-3

026366

.030 0.76

.060 1.5

.665 16.9

215 320

TP(I/S-0S)16PN-4

026367

.030 0.76

.060 1.5

.695 17.7

240 357

TP(I/S-0S)16PN-5

026368

.030 0.76

.060 1.5

.740 18.8

275 409

TP(I/S-0S)16PN-6

026369

.030 0.76

.060 1.5

.805 20.1

320 476

TP(I/S-0S)16PN-7

026370

.030 0.76

.060 1.5

.805 20.1

345 513

TP(I/S-0S)16PN-8

026371

.030 0.76

.080 2.0

.985 25.0

475 707

TP(I/S-0S)16PN-10

026372

10

.030 0.76

.080 2.0

1.010 25.7

510 759

TP(I/S-0S)16PN-12

026373

12

.030 0.76

.080 2.0

1.065 27.1

585 871

TP(I/S-0S)16PN-16

026374

16

.030 0.76

.080 2.0

1.185 30.1

750 1116

TP(I/S-0S)16PN-20

026375

20

.030 0.76

.080 2.0

1.305 33.2

915 1362

TP(I/S-0S)16PN-24

026376

24

.030 0.76

.110 2.8

1.520 38.6

1165 1734

Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TP(0S)14PN-1

026377

.030 0.76

.060 1.5

.395 10.0

85 126

TP(I/S-0S)14PN-2

026378

.030 0.76

.060 1.5

.640 16.3

180 268

TP(I/S-0S)14PN-3

026379

.030 0.76

.060 1.5

.680 17.3

235 350

TP(I/S-0S)14PN-4

026380

.030 0.76

.060 1.5

.650 19.1

290 432

TP(I/S-0S)14PN-5

026381

.030 0.76

.060 1.5

.810 20.6

345 513

TP(I/S-0S)14PN-6

026382

.030 0.76

.080 2.0

.920 23.4

450 670

TP(I/S-0S)14PN-7

026383

.030 0.76

.080 2.0

.920 23.4

475 707

TP(I/S-0S)14PN-8

026384

.030 0.76

.080 2.0

.995 25.3

540 804

TP(I/S-0S)14PN-10

026385

10

.030 0.76

.080 2.0

1.070 27.2

635 945

TP(I/S-0S)14PN-12

026386

12

.030 0.76

.080 2.0

1.165 29.6

760 1131

TP(I/S-0S)14PN-16

026387

16

.030 0.76

.080 2.0

1.300 33.0

975 1451

TP(I/S-0S)14PN-20

026388

20

.030 0.76

.110 2.8

1.490 37.9

1280 1905

TP(I/S-0S)14PN-24

026389

24

.030 0.76

.110 2.8

1.670 42.4

1515 2255

Type
Designation

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

14 AWG 1.94 mm2


Type
Designation

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

92

www.DrakaMOG.com

Bostrig Type P
0807
Page 21 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
armored and sheathed

TYPE P SIGNAL CABLE


600V or 0.6/1kV
1

Applications
BostrigTM Type P Marine and Offshore Cable is
primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.
Bostrig cables have excellent resistance to oil, abrasion,
moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.
The standard insulation has a continuous operating
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

16 & 14 AWG
Approvals
ETL/Intertek Testing Services Listed as Marine Shipboard
Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Det Norske Veritas Type Approval Certificates E8792,
E8793, E8794, E8795 and E8796.
American Bureau of Shipping Approval Certificate
03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J106

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket
5 Armor
6. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

93

www.DrakaMOG.com

Bostrig Type P
0807
Page 22 of 62

BOSTRIG TYPE P SIGNAL CABLE


individual and overall shielded multipair / armored and sheathed
16 & 14 AWG / 600V or 0.6/1kV
16 AWG 1.23 mm2
Type
Designation

Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Cable Diameter
Thickness
(nominal)
in mm
in mm

Characteristic
Impedance

TP(0S)16PNBS-1

026429

.030 0.76

.060 1.5

.535 13.6

68 223

0.12 39

25 82

190 283

TP(I/S-0S)16PNBS-2

026430

.030 0.76

.060 1.5

.805 20.5

68 223

0.12 39

25 82

350 521

TP(I/S-0S)16PNBS-3

026431

.030 0.76

.080 2.0

.885 22.5

68 223

0.12 39

25 82

425 632

TP(I/S-0S)16PNBS-4

026432

.030 0.76

.080 2.0

.920 23.4

68 223

0.12 39

25 82

490 729

TP(I/S-0S)16PNBS-5

026433

.030 0.76

.080 2.0

.965 24.5

68 223

0.12 39

25 82

545 811

TP(I/S-0S)16PNBS-6

026434

.030 0.76

.080 2.0

1.025 26.0

68 223

0.12 39

25 82

610 908

TP(I/S-0S)16PNBS-7

026435

.030 0.76

.080 2.0

1.025 26.0

68 223

0.12 39

25 82

635 945

TP(I/S-0S)16PNBS-8

026436

.030 0.76

.080 2.0

1.205 30.6

68 223

0.12 39

25 82

800 1191

TP(I/S-0S)16PNBS-10

026437

10

.030 0.76

.080 2.0

1.235 31.4

68 223

0.12 39

25 82

875 1302

TP(I/S-0S)16PNBS-12

026438

12

.030 0.76

.080 2.0

1.285 32.6

68 223

0.12 39

25 82

965 1436

TP(I/S-0S)16PNBS-16

026439

16

.030 0.76

.110 2.8

1.465 37.2

68 223

0.12 39

25 82

1255 1868

TP(I/S-0S)16PNBS-20

026440

20

.030 0.76

.110 2.8

1.585 40.2

68 223

0.12 39

25 82

1470 2188

TP(I/S-0S)16PNBS-24

026441

24

.030 0.76

.125 3.2

1.835 46.6

68 223

0.12 39

25 82

1860 2786

/kft - /km

Cable Weight
Inductance
Capacitance (approximate)
mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km

14 AWG 1.94 mm2


Type
Designation

Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Cable Diameter
Thickness
(nominal)
in mm
in mm

Characteristic
Impedance

TP(0S)14PNBS-1

026693

.030 0.76

.060 1.5

.575 14.6

60 197

0.10 33

28 92

220 327

TP(I/S-0S)14PNBS-2

026443

.030 0.76

.060 1.5

.820 20.8

68 223

0.12 39

25 82

385 573

TP(I/S-0S)14PNBS-3

026444

.030 0.76

.080 2.0

.900 22.9

68 223

0.12 39

25 82

490 729

TP(I/S-0S)14PNBS-4

026445

.030 0.76

.080 2.0

.970 24.6

68 223

0.12 39

25 82

575 856

TP(I/S-0S)14PNBS-5

026446

.030 0.76

.080 2.0

1.030 26.2

68 223

0.12 39

25 82

650 967

TP(I/S-0S)14PNBS-6

026447

.030 0.76

.080 2.0

1.140 29.0

68 223

0.12 39

25 82

780 1161

TP(I/S-0S)14PNBS-7

026448

.030 0.76

.080 2.0

1.140 29.0

68 223

0.12 39

25 82

810 1205

TP(I/S-0S)14PNBS-8

026449

.030 0.76

.080 2.0

1.215 30.9

68 223

0.12 39

25 82

900 1339

TP(I/S-0S)14PNBS-10

026450

10

.030 0.76

.080 2.0

1.290 32.8

68 223

0.12 39

25 82

1030 1533

TP(I/S-0S)14PNBS-12

026451

12

.030 0.76

.110 2.8

1.445 36.7

68 223

0.12 39

25 82

1250 1860

TP(I/S-0S)14PNBS-16

026452

16

.030 0.76

.110 2.8

1.580 40.1

68 223

0.12 39

25 82

1525 2269

TP(I/S-0S)14PNBS-20

026453

20

.030 0.76

.125 3.2

1.800 45.7

68 223

0.12 39

25 82

1960 2917

TP(I/S-0S)14PNBS-24

026454

24

.030 0.76

.125 3.2

1.980 50.3

68 223

0.12 39

25 82

2260 3363

/kft - /km

Cable Weight
Inductance
Capacitance (approximate)
mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

94

www.DrakaMOG.com

Bostrig Type P
0807
Page 43 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
unarmored

TYPE P CONTROL CABLE


600V or 0.6/1kV
1

20 & 18 AWG

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

TM

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates No.


95/00161 (E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured tc BIW Specifying Standard J105

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test
in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45
(1998) for 600V.
Bostrig Type P cables comply with the Crush and Impact requirements of UL 2225.

95

www.DrakaMOG.com

Bostrig Type P
0807
Page 44 of 62

BOSTRIG TYPE P CONTROL CABLE


individual and overall shielded multipair / unarmored
20 & 18 AWG / 600V or 0.6/1kV
20 AWG 0.61 mm2
Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Thickness
in mm

TP(0S)20PN-1

026338

.030 0.76

.060 1.5

.330 8.4

55 92

TP(I/S-0S)20PN-2

026339

.030 0.76

.060 1.5

.540 13.7

120 179

TP(I/S-0S)20PN-3

026340

.030 0.76

.060 1.5

.550 13.9

135 201

TP(I/S-0S)20PN-4

026341

.030 0.76

.060 1.5

.600 15.2

165 246

TP(I/S-0S)20PN-5

026342

.030 0.76

.060 1.5

.650 16.5

190 283

TP(I/S-0S)20PN-6

026343

.030 0.76

.060 1.5

.700 17.8

215 320

TP(I/S-0S)20PN-7

026344

.030 0.76

.060 1.5

.700 17.8

230 342

TP(I/S-0S)20PN-8

026345

.030 0.76

.060 1.5

.760 19.3

265 394

TP(I/S-0S)20PN-10

026346

10

.030 0.76

.080 2.0

.900 22.9

360 536

TP(I/S-0S)20PN-12

026347

12

.030 0.76

.080 2.0

.925 23.5

400 595

TP(I/S-0S)20PN-16

026348

16

.030 0.76

.080 2.0

1.030 26.2

510 759

TP(I/S-0S)20PN-20

026349

20

.030 0.76

.080 2.0

1.130 28.7

600 893

TP(I/S-0S)20PN-24

026350

24

.030 0.76

.080 2.0

1.265 32.1

720 1071

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

Type
Designation

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

18 AWG 0.96 mm2


Type
Designation

Draka
Number

TP(0S)18PN-1

.030 0.76

.060 1.5

.350 8.9

65 97

TP(I/S-0S)18PN-2

026352

.030 0.76

.060 1.5

.605 15.4

160 238

TP(I/S-0S)18PN-3

026353

.030 0.76

.060 1.5

.635 16.1

180 268

TP(I/S-0S)18PN-4

026354

.030 0.76

.060 1.5

.675 17.2

225 335

TP(I/S-0S)18PN-5

026355

.030 0.76

.060 1.5

.710 18.0

245 365

TP(I/S-0S)18PN-6

026356

.030 0.76

.060 1.5

.765 19.4

285 424

TP(I/S-0S)18PN-7

026357

.030 0.76

.060 1.5

.800 20.3

340 506

TP(I/S-0S)18PN-8

026358

.030 0.76

.080 2.0

.960 24.4

440 655

TP(I/S-0S)18PN-10

026359

10

.030 0.76

.080 2.0

1.025 26.0

515 766

TP(I/S-0S)18PN-12

026360

12

.030 0.76

.080 2.0

1.045 26.5

565 841

TP(I/S-0S)18PN-16

026361

16

.030 0.76

.080 2.0

1.160 29.5

720 1071

TP(I/S-0S)18PN-20

026362

20

.030 0.76

.080 2.0

1.240 31.5

825 1228

TP(I/S-0S)18PN-24

026363

24

.030 0.76

.110 2.8

1.450 36.8

1060 1577

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

96

www.DrakaMOG.com

Bostrig Type P
0807
Page 19 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
armored and sheathed

TYPE P SIGNAL CABLE


600V or 0.6/1kV
1

20 & 18 AWG

Applications

Approvals

Bostrig Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

TM

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J106

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket
5. Armor
6. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

97

www.DrakaMOG.com

Bostrig Type P
0807
Page 20 of 62

BOSTRIG TYPE P SIGNAL CABLE


individual and overall shielded multipair / armored and sheathed
20 & 18 AWG / 600V or 0.6/1kV
20 AWG 0.61 mm2
Type
Designation

Draka
Number

Number of
Pairs

Insulation
Thickness
in mm

Sheath
Cable Diameter
Thickness
(nominal)
in mm
in mm

Characteristic
Impedance

TP(0S)20PNBS-1

026403

.030 0.76

.060 1.5

.510 13.0

82 269

0.14 46

21 69

170 253

TP(I/S-0S)20PNBS-2

026404

.030 0.76

.060 1.5

.720 18.3

82 269

0.14 46

21 69

295 439

TP(I/S-0S)20PNBS-3

026405

.030 0.76

.060 1.5

.730 18.5

82 269

0.14 46

21 69

320 476

TP(I/S-0S)20PNBS-4

026406

.030 0.76

.060 1.5

.780 19.8

82 269

0.14 46

21 69

360 536

TP(I/S-0S)20PNBS-5

026407

.030 0.76

.080 2.0

.890 22.6

82 269

0.14 46

21 69

440 655

TP(I/S-0S)20PNBS-6

026408

.030 0.76

.080 2.0

.925 23.5

82 269

0.14 46

21 69

485 722

TP(I/S-0S)20PNBS-7

026409

.030 0.76

.080 2.0

.925 23.5

82 269

0.14 46

21 69

500 744

TP(I/S-0S)20PNBS-8

026410

.030 0.76

.080 2.0

.980 24.9

82 269

0.14 46

21 69

550 818

TP(I/S-0S)20PNBS-10

026411

10

.030 0.76

.080 2.0

1.120 28.5

82 269

0.14 46

21 69

690 1027

TP(I/S-0S)20PNBS-12

026412

12

.030 0.76

.080 2.0

1.150 29.2

82 269

0.14 46

21 69

730 1086

TP(I/S-0S)20PNBS-16

026413

16

.030 0.76

.080 2.0

1.250 31.8

82 269

0.l4 46

21 69

885 1317

TP(I/S-0S)20PNBS-20

026414

20

.030 0.76

.080 2.0

1.350 34.3

82 269

0.14 46

21 69

1060 1577

TP(I/S-0S)20PNBS-24

026415

24

.030 0.76

.110 2.8

1.545 39.2

82 269

0.14 46

21 69

1260 1875

Insulation
Thickness
in mm

Sheath
Cable Diameter
Thickness
(nominal)
in mm
in mm

/kft - /km

Cable Weight
Inductance
Capacitance (approximate)
mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km

18 AWG 0.96 mm2


Characteristic
Impedance

Cable Weight
Inductance
Capacitance (approximate)
mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km

Type
Designation

Draka
Number

Number of
Pairs

TP(0S)18PNBS-1

026664

.030 0.76

.060 1.5

.535 13.6

73 239

0.13 43

23 75

185 275

TP(I/S-0S)18PNBS-2

026417

.030 0.76

.060 1.5

.785 19.5

73 239

0.13 43

23 75

350 521

TP(I/S-0S)18PNBS-3

026418

.030 0.76

.060 1.5

.845 21.5

73 239

0.13 43

23 75

395 588

TP(I/S-0S)18PNBS-4

026419

.030 0.76

.080 2.0

.895 22.7

73 239

0.13 43

23 75

465 692

TP(I/S-0S)18PNBS-5

026420

.030 0.76

.080 2.0

.930 23.6

73 239

0.13 43

23 75

505 752

TP(I/S-0S)18PNBS-6

026421

.030 0.76

.080 2.0

.990 25.2

73 239

0.13 43

23 75

570 848

TP(I/S-0S)18PNBS-7

026422

.030 0.76

.080 2.0

1.020 25.9

73 239

0.13 43

23 75

605 900

TP(I/S-0S)18PNBS-8

026423

.030 0.76

.080 2.0

1.180 30.0

73 239

0.13 43

23 75

725 1079

TP(I/S-0S)18PNBS-10

026424

10

.030 0.76

.080 2.0

1.245 31.6

73 239

0.13 43

23 75

845 1257

TP(I/S-0S)18PNBS-12

026425

12

.030 0.76

.080 2.0

1.265 32.1

73 239

0.13 43

23 75

910 1354

TP(I/S-0S)18PNBS-16

026426

16

.030 0.76

.110 2.8

1.440 36.6

73 239

0.13 43

23 75

1135 1689

TP(I/S-0S)18PNBS-20

026427

20

.030 0.76

.110 2.8

1.520 38.6

73 239

0.13 43

23 75

1350 2009

TP(I/S-0S)18PNBS-24

026428

24

.030 0.76

.110 2.8

1.760 44.7

73 239

0.13 43

23 75

1680 2500

/kft - /km

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

98

www.DrakaMOG.com

Bostrig Type P
0807
Page 47 of 62

BOSTRIG TYPE P SIGNAL CABLE


Individual and overall shielded multi-triad
/ unarmored

TYPE P SIGNAL CABLE


600V or 0.6/1kV
1

18 & 16 AWG

Applications

Approvals

BostrigTM Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.

This product is readily available in an armored and


sheathed version.

Lloyds Registry of Shipping Approval Certificates No.


95/00161 (E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured tc BIW Specifying Standard J106

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

99

www.DrakaMOG.com

Bostrig Type P
0807
Page 48 of 62

BOSTRIG TYPE P SIGNAL CABLE


individual and overall shielded multitriad / unarmored
18 & 16 AWG / 0.6/1kV
18 AWG 0.96 mm2
Type
Designation

Draka
Number

TT(0S)18PN-1

Number of
Triads

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

.030 0.76

.060 1.5

.360 9.1

75 111

TT(I/S-0S)18PN-2

026456

.030 0.76

.060 1.5

.605 15.4

165 246

TT(I/S-0S)18PN-3

026457

.030 0.76

.060 1.5

.640 16.3

210 313

TT(I/S-0S)18PN-4

026458

.030 0.76

.060 1.5

.705 17.9

265 394

TT(I/S-0S)18PN-5

026459

.030 0.76

.060 1.5

.775 19.7

315 469

TT(I/S-0S)18PN-6

026460

.030 0.76

.080 2.0

.880 22.4

390 580

TT(I/S-0S)18PN-8

026461

.030 0.76

.080 2.0

.955 24.5

495 737

TT(I/S-0S)18PN-12

026462

12

.030 0.76

.080 2.0

1.155 29.3

715 1064

Draka
Number

Number of
Triads

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TT(0S)16PN-1

026625

.030 0.76

.060 1.5

.370 9.4

85 126

TT(I/S-0S)16PN-2

026465

.030 0.76

.060 1.5

.630 16.0

180 268

TT(I/S-0S)16PN-3

026466

.030 0.76

.060 1.5

.670 17.0

235 350

TT(I/S-0S)16PN-4

026467

.030 0.76

.060 1.5

.740 18.8

295 439

TT(I/S-0S)16PN-5

026468

.030 0.76

.060 1.5

.815 20.7

355 528

TT(I/S-0S)16PN-6

026469

.030 0.76

.080 2.0

.915 23.1

446 662

TT(I/S-0S)16PN-8

026470

.030 0.76

.080 2.0

1.070 27.2

625 930

TT(I/S-0S)16PN-12

026471

12

.030 0.76

.080 2.0

1.215 30.9

805 1198

TT(I/S-0S)16PN-16

026472

16

.030 0.76

.080 2.0

1.360 34.5

1050 1563

16 AWG 1.23 mm2


Type
Designation

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

100

www.DrakaMOG.com

Bostrig Type P
0807
Page 23 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multi-triad
/ armored and sheathed

TYPE P SIGNAL CABLE


600V or 0.6/1kV
1

18 & 16 AWG

Applications

Approvals

BostrigTM Type P Marine and Offshore Cable is


primarily designed for power, control, signal and
instrumentation applications for offshore, land rigs,
marine vessels and oil and gas drilling rigs.

ETL/Intertek Testing Services Listed as Marine Shipboard


Cable in accordance with IEEE 45 (1998), IEEE 1580
(2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.

Bostrig cables have excellent resistance to oil, abrasion,


moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush
and impact resistance requirements (C&IR) of UL 2225.

Det Norske Veritas Type Approval Certificates E8792,


E8793, E8794, E8795 and E8796.

The standard insulation has a continuous operating


temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).

American Bureau of Shipping Approval Certificate


03-HS347018C/3-PDA.
Lloyds Registry of Shipping Approval Certificates
No. 95/00161(E3) and 95-00162(E3)
Transport Canada Approved AMS400-20-2
Manufactured to BIW Specifying Standard J106

This product is readily available in an unarmored version.

Construction
1. Conductors
2. Insulation
3. Shield
4. Jacket
5 Armor
6. Sheath

Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown on data sheet for unarmored version.
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

101

www.DrakaMOG.com

Bostrig Type P
0807
Page 24 of 62

BOSTRIG TYPE P SIGNAL CABLE


individual and overall shielded multi-triad / armored and sheathed
18 & 16 AWG / 0.6/1kV
18 AWG 0.96 mm2
Type
Designation

Draka
Number

Number of
Triads

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TT(0S)18PNBS-1

026473

.030 0.76

.060 1.5

.540 13.7

200 298

TT(I/S-0S)18PNBS-2

026474

.030 0.76

.060 1.5

.785 19.9

360 536

TT(I/S-0S)18PNBS-3

026475

.030 0.76

.060 1.5

.850 21.6

430 640

TT(I/S-0S)18PNBS-4

026476

.030 0.76

.080 2.0

.930 23.6

525 781

TT(I/S-0S)18PNBS-5

026477

.030 0.76

.080 2.0

.995 25.3

590 878

TT(I/S-0S)18PNBS-6

026478

.030 0.76

.080 2.0

1.100 28.0

715 1064

TT(I/S-0S)18PNBS-8

026479

.030 0.76

.080 2.0

1.175 29.9

825 1228

TT(I/S-0S)18PNBS-12

026480

12

.030 0.76

.110 2.8

1.440 36.6

1180 1756

TT(I/S-0S)18PNBS-16

026481

16

.030 0.76

.110 2.8

1.570 39.9

1450 2158

16 AWG 1.23 mm2


Type
Designation

Draka
Number

Number of
Triads

Insulation
Thickness
in mm

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Cable Weight
(approximate)
Lbs/mft Kg/km

TT(0S)16PNBS-1

026716

.030 0.76

.060 1.5

.550 14.0

210 313

TT(I/S-0S)16PNBS-2

026483

.030 0.76

.060 1.5

.810 20.6

380 566

TT(I/S-0S)16PNBS-3

026484

.030 0.76

.080 2.0

.890 22.6

485 722

TT(I/S-0S)16PNBS-4

026485

.030 0.76

.080 2.0

.960 24.4

570 848

TT(I/S-0S)16PNBS-5

026486

.030 0.76

.080 2.0

1.035 26.3

645 960

TT(I/S-0S)16PNBS-6

026487

.030 0.76

.080 2.0

1.130 28.7

770 1146

TT(I/S-0S)16PNBS-8

026488

.030 0.76

.080 2.0

1.290 32.8

950 1414

TT(I/S-0S)16PNBS-12

026489

12

.030 0.76

.110 2.8

1.495 38.0

1280 1905

TT(I/S-0S)16PNBS-16

026490

16

.030 0.76

.110 2.8

1.640 41.7

1565 2329

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

102

www.DrakaMOG.com

Bostrig Type P
0807
Page 57 of 62

BOSTRIG TYPE P-VFD POWER CABLE 2000V


Shielded three conductor / unarmored or
armored and sheathed

TYPE P VFD CABLE


2000V
1

1/0 AWG to 777 MCM

Applications
BostrigTM Type P shielded three conductor VFD Marine and Offshore Cable is designed specifically for use with
variable frequency AC motor drives. This cable is ETL listed per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.
Bostrig cables have excellent resistance to oil, abrasion, moisture and sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I applications (armored & sheathed) and meet the crush and
impact resistance requirements (C&IR) of UL 2225 and complies with UL 1277 Type TC exposed runs requirements.
The standard insulation has a continuous operating temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product can be manufactured in an unarmored or armored and sheathed version.

Construction
1. Conductors
2. Insulation
3. Ground Conductors

4. Shield
5. Jacket
6. Armor (Optional)
7. Sheath (Optional)

Soft annealed tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Insulation is printed with phase markings as required.
All Bostrig Type P-VFD Cables listed in this specification sheet are built using system
grounds equal to the aggregte cross-section of a phase conductor and can be in contact with
or isolated from the overall shield. A system ground is REQUIRED for supplying power from
the switchboard to the inverter and then to the motor. If the VFD cable is only being used
between the motor and the inverter, a cable with a lesser ground can be ordered.
Braided tinner cooper for 95% coverage.
Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001).
Braided bronze in accordance with IEEE 1580 (2001).
Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Low smoke/zero halogen construction meets appropriate IEEE and IEC standards for fire, smoke, and toxicity
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Gigabit Ethernet 802.3Z compliant

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for 2000V.
Type approved by DNV, ABS, Lloyds and Transport Canada.
Bostrig Type P cables comply to UL 1277 Type TC exposed runs
requirements and with the crush and impact requirements of UL 2225.

103

www.DrakaMOG.com

Bostrig Type P
0807
Page 58 of 62

BOSTRIG TYPE P-VFD POWER CABLE


shielded three conductor / unarmored or armored and sheathed
1/0 AWG to 777 MCM / 2000V
unarmored
Ground Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Inductance
/kft - /km

Capacitance
pF/ft pF/m

Calculated Ampacity Cable Weight


(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

TP(OBS)N-1/0

036028

1/0 56.3

5 AWG 18.6

n/a

1.53 38.9

0.09 0.3

190 623

156 164 176

2280 3393

TP(OBS)N-2/0

036029

2/0 66.5

4 AWG 21.5

n/a

1.63 41.4

0.09 0.3

212 695

175 186 201

2640 3928

TP(OBS)N-4/0

036030

4/0 112.6

1 AWG 56.3

n/a

2.09 53.1

0.09 0.3

259 850

241 252 270

4480 6666

TP(OBS)N-262

036031

262 133.0

1 AWG 56.3

n/a

2.23 56.6

0.09 0.3

247 810

267 294 315

5050 7514

TP(OBS)N-313

036032

313 158.6

110 AWG 18.6

n/a

2.36 60.0

0.08 0.2

270 886

298 321 344

5860 8720

TP(OBS)N-373

036033

373 189.3

210 AWG 61.5

n/a

2.56 65.0

0.08 0.2

292 958

333 361 387

6950 10342

TP(OBS)N-444

036034

444 225.1

310 AWG 92.1

n/a

2.87 72.9

0.08 0.2

318 1043

371 411 440

8660 12886

TP(OBS)N-535

036035

535 271.2

310 AWG 92.1

n/a

3.03 77.0

0.09 0.3

291 954

417 443 475

9700 14437

TP(OBS)N-646

036036

646 327.5

410 AWG 112.6

n/a

3.18 80.8

0.09 0.3

314 1030

469 516 553

11400 16963

TP(OBS)N-777

036037

777 393.8

262 KCMIL 133.0

n/a

3.52 89.4

0.09 0.3

345 1132

528 582 602

13520 20118

Ground Size
AWG/MCM mm2

Sheath
Thickness
in mm

Cable Diameter
(nominal)
in mm

Inductance
/kft - /km

Capacitance
pF/ft pF/m

armored and sheathed


Calculated Ampacity Cable Weight
(measured @ C)
(approximate)
95 100 110
Lbs/mft Kg/km

Type
Designation

Draka
Number

Conductor Size
AWG/MCM mm2

TP(OBS)NBS-1/0

036038

4/0 112.6

5 AWG 18.6

.11 2.8

1.82 46.2

0.09 0.3

190 623

156 164 176

3020 4494

TP(OBS)NBS-2/0

036039

4/0 112.6

4 AWG 21.5

.11 2.8

1.92 48.8

0.09 0.3

212 695

175 188 201

3420 5089

TP(OBS)NBS-4/0

036040

4/0 112.6

1 AWG 56.3

.11 2.8

2.38 60.4

0.09 0.3

259 850

241 252 270

5510 8199

TP(OBS)NBS-262

036041

262 133.1

1 AWG 56.3

.11 2.8

2.52 64.0

0.09 0.3

247 810

267 294 315

6130 9121

TP(OBS)NBS-313

036042

313 158.7

110 AWG 18.6

.11 2.8

2.65 67.3

0.08 0.2

270 886

298 321 344

7010 10431

TP(OBS)NBS-373

036043

373 189.2

210 AWG 61.5

.14 3.6

2.90 73.7

0.08 0.2

292 958

333 361 387

8360 12440

TP(OBS)NBS-444

036044

444 225.2

310 AWG 92.1

.14 3.6

3.21 81.5

0.08 0.2

318 1043

371 411 440

10230 15222

TP(OBS)NBS-535

036045

535 271.3

310 AWG 92.1

.14 3.6

3.37 85.6

0.09 0.3

291 954

417 443 475

11350 16889

TP(OBS)NBS-646

036046

646 327.5

410 AWG 112.6

.14 3.6

3.52 89.4

0.09 0.3

314 1030

469 516 553

13130 19537

TP(OBS)NBS-777

036047

777 394.2

262 KCMIL 133.0

.14 3.6

3.86 98.0

0.09 0.3

345 1132

528 582 602

15420 22944

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

PHASE CONDUCTOR (3)


SYSTEM GROUND (3)
FILLERS (AS REQUIRED)
MYLAR TAPE
BRAIDED SHIELD
JACKET
BRAIDED ARMOR
SHEATH

104

www.DrakaMOG.com

Marine & Offshore


Product Specification J-124

IECIEEEUL
Conductor

BOSTRIG MHV-15 CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Single Conductor Power (Type N Jacket)


15 kV (IEC 12/20 kV) Shielded - 133% Level
Unarmored

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-124, and flame test in
IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Bostrig MHV-15 single conductor 15,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c 15 kV (IEC 12/20 kV) Shielded - 133% Level 108


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
AWG/MCM

MHV-15-2
MHV-15-1
MHV-15-1/0
MHV-15-2/0
MHV-15-3/0
MHV-15-4/0
MHV-15-262
MHV-15-313
MHV-15-373
MHV-15-444
MHV-15-535
MHV-15-646
MHV-15-777
MHV-15-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Nominal
Cable Diameter

Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220

5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59

.080
.080
.080
.080
.085
.085
.085
.090
.090
.110
.110
.110
.110
.115

2.03
2.03
2.03
2.03
2.16
2.16
2.16
2.29
2.29
2.80
2.80
2.80
2.80
2.92

1.130
1.200
1.250
1.270
1.400
1.450
1.500
1.580
1.660
1.770
1.860
1.980
2.070
2.300

28.70
30.48
31.75
32.26
35.56
36.83
38.10
40.13
42.16
44.96
47.24
50.29
52.58
58.42

790
950
1050
1150
1430
1600
1760
2000
2250
2620
3000
3500
4000
5300

1175
1414
1563
1711
2128
2381
2619
2976
3348
3899
4464
5209
5953
7887

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

105

www.drakausa.com

ISO9001
QSC3497
BG_MHV15_108_109_2_00

TYPE N JACKET 15KV

Application

Marine & Offshore


Product Specification J-120

IECIEEEUL
Conductor

BOSTRIG MHV-15 CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Single Conductor Power (Type N Jacket)


15 kV (IEC 8.7/15 kV) Shielded - 100% Level
Unarmored

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-120, and
flame test in IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Bostrig MHV-15 single conductor 15,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c - 15 kV (IEC 8.7/15 kV) Shielded - 100% Level 106


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
AWG/MCM

MHV-15-2
MHV-15-1
MHV-15-1/0
MHV-15-2/0
MHV-15-3/0
MHV-15-4/0
MHV-15-262
MHV-15-313
MHV-15-373
MHV-15-444
MHV-15-535
MHV-15-646
MHV-15-777
MHV-15-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Nominal
Cable Diameter

Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177

4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50

.080
.080
.080
.080
.080
.080
.085
.085
.090
.090
.110
.110
.110
.110

2.03
2.03
2.03
2.03
2.03
2.03
2.16
2.16
2.29
2.29
2.80
2.80
2.80
2.80

1.050
1.110
1.170
1.190
1.310
1.370
1.420
1.480
1.560
1.630
1.760
1.870
2.970
2.190

26.67
28.19
29.72
30.23
33.27
34.80
36.07
37.59
39.62
41.10
44.71
47.50
50.04
55.63

700
860
960
1040
1310
1480
1650
1860
2120
2410
2850
3270
3800
5100

1042
1280
1429
1548
1950
2202
2455
2768
3155
3586
4241
4866
5655
7590

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

106

www.drakausa.com

ISO9001
QSC3497
BG_MHV15_106_107_2_00

TYPE N JACKET 15KV

Application

Marine & Offshore


Product Specification J-124

IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV-15B CABLE

Conductor Shield

Single Conductor Power (Type N Jacket)


15 kV - Shielded - 133% Level
Armored Only

Semi-conducting tape with extruded thermosetting semi-conducting


EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-124, and flame test in IEC 60332-3, cat
A, A/F.

Application
Bostrig MHV-15B single conductor 15,000 volt shielded cables are suitable for use in commercial marine applications, MODUs, and platforms where flame retardant cables having
excellent physical and electrical properties are required. The cables have excellent resistance to
oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with
either a fully insulated grounding conductor or an un-insulated grounding conductor evenly
distributed in the interstices.

1/c- 15 kV Shielded - 133% Level 174


BIW
Cable Type
Conductor Size

TYPE N JACKET 15KV

AWG/MCM

MHV-15B-2
MHV-15B-l
MHV-15B-l/0
MHV-15B-2/0
MHV-15B-3/0
MHV-15B-4/0
MHV-15B-262
MHV-15B-313
MHV-15B-373
MHV-15B-444
MHV-15B-535
MHV-15B-646
MHV-15B-777
MHV-15B-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Insulation
Jacket
Wall Thickness Wall Thickness

Nominal
Cable Diameter

Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220

5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59

.080
.080
.080
.080
.085
.085
.085
.090
.090
.110
.110
.110
.110
.115

2.03
2.03
2.03
2.03
2.16
2.16
2.16
2.29
2.29
2.80
2.80
2.80
2.80
2.92

1.190
1.260
1.310
1.330
1.460
1.510
1.560
1.640
1.720
1.830
1.920
2.040
2.130
2.360

30.23
32.00
33.27
33.78
37.08
38.35
39.62
41.66
43.69
46.48
48.77
51.82
54.10
59.94

970
1130
1280
1380
1680
1870
2050
2300
2550
2950
3350
3900
4400
5750

1444
1756
1905
2054
2500
2783
3051
3423
3795
4390
4985
5804
6548
8557

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

107

www.drakausa.com

ISO9001
QSC3497
BG_MHV15B_174_2_00

Marine & Offshore


Product Specification J-120

IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV-15B CABLE

Conductor Shield

Single Conductor Power (Type N Jacket)


15 kV - Shielded - 100% Level
Armored Only

Semi-conducting tape with extruded thermosetting semi-conducting


EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-120 and flame test in IEC 60332-3, cat
A, A/F.

Rating

Application

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

1/c- 15 kV Shielded - 100% Level 171


BIW
Cable Type
Conductor Size
AWG/MCM

MHV-15B-2
MHV-15B-1
MHV-15B-1/0
MHV-15B-2/0
MHV-15B-3/0
MHV-15B-4/0
MHV-15B-262
MHV-15B-313
MHV-15B-373
MHV-15B-444
MHV-15B-535
MHV-15B-646
MHV-15B-777
MHV-15B-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Insulation
Jacket
Wall Thickness Wall Thickness

Nominal
Cable Diameter

Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177

4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50

.080
.080
.080
.080
.080
.080
.085
.085
.090
.090
.110
.110
.110
.110

2.03
2.03
2.03
2.03
2.03
2.03
2.16
2.16
2.29
2.29
2.80
2.80
2.80
2.80

1.110
1.170
1.230
1.250
1.370
1.430
1.480
1.540
1.620
1.690
1.820
1.930
2.030
2.250

28.19
29.72
31.24
31.75
34.80
36.32
37.59
39.12
41.15
42.93
46.23
49.02
51.56
57.15

860
1040
1140
1220
1550
1720
1900
2150
2400
2750
3200
3650
4150
5500

1280
1547
1697
1816
2307
2560
2828
3200
3572
4092
4762
5432
6176
8185

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

108

www.drakausa.com

ISO9001
QSC3497
BG_MHV5BS_171_2_00

TYPE N JACKET 15KV

Bostrig MHV-15B single conductor 15,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

Marine & Offshore


Product Specification J-124

IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV-15BS CABLE


Single Conductor Power (Type N Jacket & Sheath)
15 kV (IEC 12/20 kV) Shielded - 133% Level
Armored and Sheathed

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the cabled core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-124, and flame test in
IEC 60332-3, cat A, A/F.

Rating

Application
Bostrig MHV-15BS single conductor 15,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these
cables can be supplied without the sheath over the armor.

1/c 15 kV (IEC 12/20 kV) Shielded - 133% Level 109


BIW
Insulation
Cable Type
Conductor Size
Wall Thickness

TYPE N JACKET 15KV

AWG.MCM

MHV-15BS-2
MHV-15BS-1
MHV-15BS-l/0
MHV-15BS-2/0
MHV-15BS-3/0
MHV-15BS-4/0
MHV-15BS-262
MHV-15BS-313
MHV-15BS-373
MHV-15BS-444
MHV-15BS-535
MHV-15BS-646
MHV-15BS-777
MHV-15BS-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Jacket/Sheath
Wall Thickness

Nominal
Cable Diameter Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220

5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59

.080/.080
.080/.080
.080/.080
.080/.080
.085/.080
.085/.080
.085/.080
.090/.110
.090/.110
.110/.110
.110/.110.
.110/.110
.110/.110
.115/.110

2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.16/2.03
2.16/2.03
2.16/2.80
2.29/2.80
2.29/2.80
2.80/2.80
2.80/2.80
2.80/2.80
2.80/2.80
2.92/2.80

1.360
1.420
1.470
1.490
1.630
1.680
1.790
1.870
1.940
2.050
2.150
2.260
2.360
2.580

34.54
36.07
37.34
37.85
41.40
42.67
45.47
47.59
49.28
52.07
54.61
57.40
59.94
65.53

1200
1400
1500
1600
1920
2100
2400
2650
2950
3400
3800
4300
4800
6200

1786
2083
2232
2381
2857
3125
3571
3943
4390
5060
5655
6399
7143
9227

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

109

www.drakausa.com

ISO9001
QSC3497
BG_MHV15_108_109_2_00

Marine & Offshore


Product Specification J-120

IECIEEEUL
Conductor

BOSTRIG MHV-15BS CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Single Conductor Power (Type N Jacket & Sheath)


15 kV (IEC 8.7/15 kV) Shielded - 100% Level
Armored and Sheathed

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the metallic braid shield and outer
sheath over the armor are flame retardant, heavy duty arctic
Neoprene. Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-120, and
flame test in IEC 60332-3, cat A, A/F.

Application
Bostrig MHV-15BS single conductor 15,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these
cables can be supplied without the sheath over the armor.

1/c - 15 kV (IEC 8.7/15kV) Shielded - 100% Level 107


BIW
Insulation
Cable Type
Conductor Size
Wall Thickness

TYPE N JACKET 15KV

AWG.MCM

MHV-15BS-2
MHV-15BS-1
MHV-15BS-1/0
MHV-15BS-2/0
MHV-15BS-3/0
MHV-15BS-4/0
MHV-15BS-262
MHV-15BS-313
MHV-15BS-373
MHV-15BS-444
MHV-15BS-535
MHV-15BS-646
MHV-15BS-777
MHV-15BS-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance
to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
approved by DNV, ABS and LRS.

Jacket/Sheath
Wall Thickness

Nominal
Cable Diameter Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177

4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50

.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.085/.080
.085/.110
.090/.110
.090/.110
.110/.110
.110/.110
.110/.110
.110/.110

2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.16/2.03
2.16/2.80
2.29/2.80
2.29/2.80
2.80/2.80
2.80/2.80
2.80/2.80
2.80/2.80

1.270
1.330
1.390
1.410
1.530
1.580
1.640
1.760
1.850
1.920
2.050
2.150
2.260
2.480

32.26
33.78
35.31
35.81
38.86
40.13
41.66
44.70
46.99
48.77
52.07
54.61
57.40
62.99

1060
1240
1360
1440
1780
1960
2140
2500
2790
3100
3600
4050
4620
6000

1577
1845
2024
2143
2649
2917
3185
3720
4152
4613
5357
6027
6875
8929

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

110

www.drakausa.com

ISO9001
QSC3497
BG_MHV15_106_107_2_00

Product Specification J-121

IECIEEEUL
Conductor

BOSTRIG MHV-5 CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Single Conductor Power (Type N Jacket)


5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level
Unarmored

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-121, and flame test in
IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Application
Bostrig MHV-5 single conductor 5,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight

1/c - 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level 100


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
MHV-5-8
MHV-5-6
MHV-5-5
MHV-5-4
MHV-5-2
MHV-5-1
MHV-5-1/0
MHV-5-2/0
MHV-5-3/0
MHV-5-4/0
MHV-5-262
MHV-5-313
MHV-5-373
MHV-5-444
MHV-5-535
MHV-5-646
MHV-5-777
MHV-5-1111

Nominal
Cable Diameter

Approx. Weight

AWG/MCM

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

8
6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

7.57
12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

37/24
61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.090
.090
.090
.090
.090
.090
.090
.090
.095
.095
.095
.095
.095
.095
.095
.103
.103
.110

2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.60
2.60
2.80

.060
.060
.060
.060
.060
.080
.080
.080
.080
.080
.080
.080
.080
.085
.090
.095
.110
.110

1.53
1.53
1.53
1.53
1.53
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.16
2.29
2.42
2.80
2.80

.660
.720
.750
.790
.850
.950
1.000
1.020
1.130
1.170
1.220
1.310
1.380
1.460
1.560
1.682
1.800
2.060

16.76
18.29
19.05
20.07
21.59
24.13
25.54
25.91
28.70
29.72
30.99
33.27
35.05
37.08
39.62
42.67
45.72
52.32

280
340
400
430
520
700
790
860
1100
1250
1400
1650
1900
2200
2550
3000
3500
4800

417
506
595
640
774
1042
1176
1280
1637
1860
2083
2456
2828
3274
3795
4465
5209
7143

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

111

www.drakausa.com

ISO9001
QSC3497
BG_MHV5_100_101_2_00

TYPE N JACKET 5KV

Marine & Offshore

Product Specification J-121

IECIEEEUL
Conductor

BOSTRIG MHV-5B CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Single Conductor Power (Type N Jacket)


5 kV - Shielded - 100% or 133% Level
Armored Only

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-121 and flame test in IEC 60332-3, cat
A, A/F.

Application

Rating

Bostrig MHV-5B single conductor 5,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

1/c- 5 kV Shielded - 100% or 133% Level 170


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
MHV-5B-8
MHV-5B-6
MHV-5B-5
MHV-5B-4
MHV-5B-2
MHV-5B-1
MHV-5B-1/0
MHV-5B-2/0
MHV-5B-3/0
MHV-5B-4/0
MHV-5B-262
MHV-5B-313
MHV-5B-373
MHV-5B-444
MHV-5B-535
MHV-5B-646
MHV-5B-777

Nominal
Cable Diameter

Approx. Weight

AWG/MCM

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

8
6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777

7.57
12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8

37/24
61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24

.090
.090
.090
.090
.090
.090
.090
.090
.095
.095
.095
.095
.095
.095
.095
.103
.103

2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.60
2.60

.060
.060
.060
.060
.060
.080
.080
.080
.080
.080
.080
.080
.080
.085
.090
.095
.110

1.53
1.53
1.53
1.53
1.53
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.16
2.16
2.42
2.80

.720
.780
.810
.850
.910
1.010
1.060
1.080
1.190
1.230
1.280
1.370
1.440
1.520
1.620
1.740
1.860

18.29
19.81
20.57
21.59
23.11
25.65
26.92
27.43
30.23
31.24
32.51
34.80
36.58
38.61
41.15
44.20
47.25

380
450
510
550
650
840
940
1020
1270
1430
1620
1840
2150
2450
2850
3300
3850

566
670
759
818
967
1250
1399
1518
1890
2128
2411
2738
3200
3646
4241
4911
5729

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

112

www.drakausa.com

ISO9001
QSC3497
BG_MHV5B_170_2_00

TYPE N JACKET 5KV

Marine & Offshore

TYPE N JACKET 5KV

Marine & Offshore


Product Specification J-121

IECIEEEUL
Conductor

BOSTRIG MHV-5BS CABLE

Soft annealed tinned copper per.


Stranding as shown in table below.

Single Conductor Power (Type N Jacket & Sheath)


5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level
Armored and Sheathed

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the metallic braid shield and outer
sheath over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze in accordance with IEEE 45-1998 & 1993 (draft).

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-121, and flame test in
IEC 60332-3, cat A, A/F.

Application
Bostrig MHV-5BS single conductor 5,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these
cables can be supplied without the sheath over the armor.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance
to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
approved by DNV, ABS and LRS.

1/c - 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level 101


BIW
Insulation
Jacket/Sheath
Cable Type
Conductor Size
Wall Thickness Wall Thickness
MHV-5BS-8
MHV-5BS-6
MHV-5BS-5
MHV-5BS-4
MHV-5BS-2
MHV-5BS-l
MHV-5BS-l/0
MHV-5BS-2/0
MHV-5BS-3/0
MHV-5BS-4/0
MHV-5BS-262
MHV-5BS-313
MHV-5BS-373
MHV-5BS-444
MHV-5BS-535
MHV-5BS-646
MHV-5BS-777
MHV-5BS-l111

Nominal
Cable Diameter Approx. Weight

AWG.MCM

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

8
6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

7.57
12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

37/24
61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.090
.090
.090
.090
.090
.090
.090
.090
.095
.095
.095
.095
.095
.095
.095
.103
.103
.110

2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.60
2.60
2.80

.060/.060
.060/.080
.060/.080
.060/.080
.060/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.085/.080
.090/.110
.095/.110
.110/.110
.110/.110

1.53/1.53
1.53/2.03
1.53/2.03
1.53/2.03
1.53/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.16/2.03
2.29/2.03
2.42/2.80
2.80/2.80
2.80/2.80

.840
.940
.970
1.010
1.080
1.170
1.220
1.240
1.350
1.390
1.440
1.530
1.600
1.690
1.840
1.960
2.090
2.340

21.34
23.88
24.64
25.65
27.43
29.72
30.99
31.50
34.29
35.31
36.58
38.86
40.64
42.93
46.74
49.78
53.09
59.44

470
580
650
700
800
1010
1120
1210
1470
1630
1850
2100
2400
2700
3200
3700
4300
5700

700
863
967
1042
1191
1503
1667
1801
2188
2426
2753
3125
3572
4018
4762
5506
6399
8483

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

113

www.drakausa.com

ISO9001
QSC3497
BG_MHV5_100_101_2_00

Marine & Offshore


Product Specification J-122

IECIEEEUL
Conductor

BOSTRIG MHV-8 CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Single Conductor Power (Type N Jacket)


8 kV (IEC 3.6/6 kV) Shielded - 100% Level
Unarmored

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-122 and
Flame test in IEC 60332-3, cat A, A/F.

Rating

Application

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Bostrig MHV-8 single conductor 8,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 102


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
AWG/MCM

MHV-8-6
MHV-8-5
MHV-8-4
MHV-8-2
MHV-8-1
MHV-8-1/0
MHV-8-2/0
MHV-8-3/0
MHV-8-4/0
MHV-8-262
MHV-8-313
MHV-8-373
MHV-8-444
MHV-8-535
MHV-8-646
MHV-8-777
MHV-8-1111

6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Nominal
Cable Diameter

Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118

3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.20

.060
.060
.060
.080
.080
.080
.080
.080
.080
.080
.080
.085
.085
.090
.110
.110
.110

1.53
1.53
1.53
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.16
2.16
2.29
2.80
2.80
2.80

.770
.810
.830
.930
.990
1.050
1.060
1.170
1.220
1.270
1.360
1.440
1.500
1.600
1.740
1.840
2.090

19.56
20.57
21.08
23.62
25.15
26.67
26.92
29.72
30.99
32.26
34.54
36.58
38.10
40.64
44.20
46.74
53.09

370
430
470
590
730
820
900
1150
1300
1450
1700
1950
2250
2600
3100
3600
4900

551
640
700
878
1086
1220
1339
1711
1935
2158
2530
2902
3348
3869
4613
5357
7292

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

114

www.drakausa.com

ISO9001
QSC3497
BG_MHV8_102_103_2_00

TYPE N JACKET 8KV

Tests

Marine & Offshore


Product Specification J-123

IECIEEEUL
Conductor

BOSTRIG MHV-8 CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Single Conductor Power (Type N Jacket)


8 kV (IEC 6/10 kV) Shielded - 133% Level
Unarmored

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core.
Thickness as shown in table below.

Tests

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance
to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
approved by DNV, ABS and LRS.

Application
Bostrig MHV-8 single conductor 8,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c - 8 kV (IEC 6/10 kv) Shielded - 133% Level 104


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
AWG/MCM

MHV-8-5
MHV-8-4
MHV-8-2
MHV-8-1
MHV-8-1/0
MHV-8-2/0
MHV-8-3/0
MHV-8-4/0
MHV-8-262
MHV-8-313
MHV-8-373
MHV-8-444
MHV-8-535
MHV-8-646
MHV-8-777
MHV-8-1111

5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Nominal
Cable Diameter

Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140

3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56

.080
.080
.080
.080
.080
.080
.080
.080
.080
.085
.085
.090
.090
.110
.110
.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03/
2.16
2.16
2.29/
2.29
2.80
2.80
2.80

.890
.920
.980
1.050
1.100
1.120
1.220
1.280
1.350
1.420
1.480
1.560
1.650
1.800
1.910
2.130

22.61
23.37
24.89
26.67
27.94
28.45
30.99
32.51
34.29
36.07
37.59
39.62
41.91
45.72
48.51
54.10

510
540
640
770
865
950
1200
1350
1550
1750
2000
2300
2650
3150
3700
4950

759
804
952
1146
1287
1414
1786
2009
2307
2604
2976
3423
3944
4688
5506
7366

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

115

www.drakausa.com

ISO9001
QSC3497
BG_MHV8_104_105_2_00

TYPE N JACKET 8KV

Meets applicable test requirements in IEC 60502, IEC 60092-354,


IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-123 and
Flame test in IEC 60332-3, cat A, A/F.

Marine & Offshore


Product Specification J-122

IECIEEEUL
Conductor

BOSTRIG MHV-8B CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Single Conductor Power (Type N Jacket)


8 kV - Shielded - 100% Level
Armored Only

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.

Armor
Braided Bronze.
Meets applicable test requirements in IEEE 45-1998 & 1993
(draft), ICEA S-68-516, UL 1072, J-122 and flame test in IEC
60332-3, cat A, A/F.

Application

Rating

Bostrig MHV-8B single conductor 8,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c - 8 kV Shielded - 100% Level 172


BIW
Cable Type
Conductor Size
AWG/MCM

MHV-8B-6
MHV-8B-5
MHV-8B-4
MHV-8B-2
MHV-8B-1
MHV-8B-l/0
MHV-8B-2/0
MHV-8B-3/0
MHV-8B-4/0
MHV-8B-262
MHV-8B-313
MHV-8B-373
MHV-8B-444
MHV-8B-535
MHV-8B-646
MHV-8B-777
MHV-8B-1111

6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Insulation
Jacket
Wall Thickness Wall Thickness

Nominal
Cable Diameter

Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.126

3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.20

.060
.060
.065
.080
.080
.080
.080
.080
.080
.080
.080
.085
.085
.090
.110
.110
.110

1.53
1.53
1.53
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.16
2.16
2.29
2.80
2.80
2.80

.830
.870
.890
.990
1.050
1.110
1.120
1.230
1.280
1.330
1.420
1.500
1.560
1.660
1.800
1.900
2.150

21.08
22.10
22.61
25.15
26.67
28.19
28.45
31.24
32.51
33.78
36.07
38.10
39.62
42.17
45.72
48.26
54.61

500
560
600
730
880
990
1070
1350
1550
1700
1950
2200
2500
2900
3400
3900
5300

744
833
893
1086
1309
1473
1592
2009
2307
2530
2902
3274
3720
4316
5060
5804
7887

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

116

www.drakausa.com

ISO9001
QSC3497
BG_MHV8B_172_2_00

TYPE N JACKET 8KV

Tests

Marine & Offshore


Product Specification J-123

IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV-8B CABLE

Conductor Shield

Single Conductor Power (Type N Jacket)


8 kV - Shielded - 133% Level
Armored Only

Semi-conducting tape with extruded thermosetting semi-conducting


EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.

Armor
Braided Bronze.

TYPE N JACKET 8KV

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-123 and flame test in IEC 60332-3, cat
A, A/F.

Rating

Application

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Bostrig MHV-8B single conductor 8,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c 8 kV Shielded - l33% Level 173


BIW
Cable Type
Conductor Size
AWG/MCM

MHV-8B-5
MHV-8B-4
MHV-8B-2
MHV-8B-1
MHV-8B-1/0
MHV-8B-2/0
MHV-8B-3/0
MHV-8B-4/0
MHV-8B-262
MHV-8B-313
MHV-8B-373
MHV-8B-444
MHV-8B-535
MHV-8B-646
MHV-8B-777
MHV-8B-1111

5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Insulation
Jacket
Wall Thickness Wall Thickness

Nominal
Cable Diameter

Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140

3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56

.080
.080
.080
.080
.080
.080
.080
.080
.080
.085
.085
.090
.090
.110
.110
.110

2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.03
2.16
2.16
2.29
2.29
2.80
2.80
2.80

.950
.980
1.040
1.110
1.160
1.180
1.280
1.340
1.410
1.480
1.540
1.620
1.710
1.860
1.970
2.190

24.13
24.89
26.42
28.19
29.46
29.97
32.51
34.04
35.81
37.59
39.12
41.15
43.43
47.24
50.04
55.63

650
680
790
940
1050
1150
1450
1600
1800
2050
2300
2600
2950
3500
4050
5350

967
1012
1176
1399
1563
1711
2158
2381
2679
3051
3423
3869
4390
5209
6027
7962

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

117

www.drakausa.com

ISO9001
QSC3497
BG_MHV8B_173_2_00

Marine & Offshore


Product Specification J-122

IECIEEEUL
Conductor

BOSTRIG MHV-8BS CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Single Conductor Power (Type N Jacket & Sheath)


8 kV (IEC 3.6/6 kV) Shielded - 100% Level
Armored and Sheathed

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the metallic braid shield and outer
sheath over the armor are flame retardant, heavy duty artic
Neoprene. Thickness as shown in table below.

Armor
Braided Bronze.

TYPE N JACKET 8KV

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-122 and
Flame test in IEC 60332-3, cat A, A/F.

Application
Bostrig MHV-8BS single conductor 5,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these
cables can be supplied without the sheath over the armor.

1/c 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 103


BIW
Insulation
Cable Type
Conductor Size
Wall Thickness
MHV-8BS-6
MHV-8BS-5
MHV-8BS-4
MHV-8BS-2
MHV-8BS-1
MHV-8BS-l/0
MHV-8BS-2/0
MHV-8BS-3/0
MHV-8BS-4/0
MHV-8BS-262
MHV-8BS-313
MHV-8BS-373
MHV-8BS-444
MHV-8BS-535
MHV-8BS-646
MHV-8BS-777
MHV-8BS-1111

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance
to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
approved by DNV, ABS and LRS.

Jacket/Sheath
Wall Thickness

Nominal
Cable Diameter Approx. Weight

AWG.MCM

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118

3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.20

.060/.080
.060/.080
.060/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.085/.080
.085/.080
.090/.110
.110/.110
.110/.110
.110/.110

1.53/2.03
1.53/2.03
1.53/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.16/2.03
2.16/2.03
2.29/2.80
2.80/2.80
2.80/2.80
2.80/2.80

.990
1.030
1.060
1.160
1.220
1.270
1.290
1.390
1.440
1.490
1.580
1.650
1.780
1.880
2.030
2.130
2.370

25.15
26.16
26.92
29.46
30.99
32.26
32.77
35.31
36.58
37.85
40.13
41.91
45.21
47.75
51.56
54.10
60.20

640
720
760
920
1100
1200
1270
1550
1750
1900
2200
2500
2900
3300
3800
4350
5750

952
1071
1131
1369
1637
1786
1890
2307
2604
2828
3274
3720
4316
4911
5655
6474
8557

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

118

www.drakausa.com

ISO9001
QSC3497
BG_MHV8_102_103_2_00

Marine & Offshore


Product Specification J-123

IECIEEEUL
Conductor

BOSTRIG MHV-8BS CABLE


Single Conductor Power (Type N Jacket & Sheath)
8 kV (IEC 6/10 kV) Shielded - 133% Level
Armored and Sheathed

Soft annealed tinned copper.


Stranding as shown in table below.

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the metallic braid shield and outer
sheath over the annor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze.

TYPE N JACKET 8KV

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA 5-68-516, UL 1072, J-123 and
Flame test in IEC 60332-3, cat A, A/F.

Application
Bostrig MHV-8BS single conductor 8,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these
cables can be supplied without the sheath over the armor.

1/c - 8 kV (IEC 6/10 kv) Shielded - 133% Level 105


BIW
Insulation
Cable Type
Conductor Size
Wall Thickness
MHV-8BS-5
MHV-8BS-4
MHV-8BS-2
MHV-8BS-1
MHV-8BS-1/0
MHV-8BS-2/0
MHV-8BS-3/0
MHV-8BS-4/0
MHV-8BS-262
MHV-8BS-313
MHV-8BS-373
MHV-8BS-444
MHV-8BS-535
MHV-8BS-646
MHV-8BS-777
MHV-8BS-1111

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance
to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
approved by DNV, ABS and LRS.

Jacket/Sheath
Wall Thickness

Nominal
Cable Diameter Approx. Weight

AWG.MCM

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140

3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56

.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.080/.080
.085/.080
.085/.110
.090/.110
.090/.110
.110/.110.
.110/.110
.110/.110

2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.03/2.03
2.16/2.03
2.16/2.80
2.29/2.80
2.29/2.80
2.80/2.80
2.80/2.80
2.80/2.80

1.120
1.050
1.210
1.270
1.320
1.340
1.440
1.500
1.570
1.640
1.770
1.850
1.940
2.080
2.190
2.410

28.45
29.21
30.73
32.26
33.53
34.04
36.58
38.10
39.88
41.66
44.96
46.99
49.28
52.83
55.63
61.21

810
860
980
1150
1250
1330
1650
1820
2030
2300
2650
3000
3400
3900
4500
5850

1205
1280
1458
1711
1860
1979
2455
2708
3021
3423
3944
4465
5060
5804
6697
8706

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

119

www.drakausa.com

ISO9001
QSC3497
BG_MHV8_104_105_2_00

Marine & Offshore


Product Specification J-129

IIECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV3-15 CABLE

Conductor Shield

Three Conductor Power (Type N Jacket)


15 kV (IEC 12/20 kV) Shielded - 133% Level
Unarmored

Semi-conducting tape with extruded thermosetting semi-conducting


EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-129, and flame test in
IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Application
Bostrig MHV3-15 three conductor 15,000 volt shielded cables are suitable for use in commercial marine applications, MODUs, and platforms where flame retardant cables having excellent
physical and electrical properties are required. The cables have excellent resistance to oils,
abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a
fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed
in the interstices.

AWG/MCM

MHV3-15-2
MHV3-15-1
MHV3-15-1/0
MHV3-15-2/0
MHV3-15-3/0
MHV3-15-4/0
MHV3-15-262
MHV3-15-313
MHV3-15-373
MHV3-15-444
MHV3-15-535
MHV3-15-646
MHV3-15-777
MHV3-15-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Nominal
Cable Diameter

mm2

Stranding

Inches

mm

Inches

mm

Inches

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220

5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59

.115
.120
.125
.130
.140
.145
.145
.155
.160
.165
.170
.185
.190
.210

2.92
3.05
3.18
3.30
3.56
3.68
3.68
3.94
4.06
4.19
4.32
4.76
4.83
5.33

2.330
2.470
2.590
2.650
2.930
3.050
3.160
3.320
3.470
3.640
3.850
4.140
4.330
4.850

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

120

www.drakausa.com

mm

59.18
62.74
65.79
67.31
74.42
77.47
80.26
84.33
88.14
92.46
97.79
105.16
109.98
123.19

Approx. Weight
Lbs/Mft

2600
3100
3500
3750
4750
5300
5850
6600
7450
8450
9700
11300
12950
17300

kg/km

3869
4613
5209
5581
7069
7887
8706
9822
11087
12575
14435
16816
19271
25745

ISO9001
QSC3497
BG_MHV3-15_118_119_2_00

TYPE N JACKET 15KV

3/c - 15 kV (IEC 12/20 kV) Shielded - 133% Level 118


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness

Marine & Offshore


Product Specification J-128

IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV3-15 CABLE

Conductor Shield

Three Conductor Power (Type N Jacket)


15 kV (IEC 8.7/15 kV) Shielded - 100% Level
Unarmored

Semi-conducting tape with extruded thermosetting semi-conducting


EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cabled core.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-128, and
flame test in IEC 60332-3, cat A, A/F.

Rating
Bostrig MHV3-15 three conductor 15,000 volt shielded cables are suitable for use in commercial
marine applications, MODUs, and platforms where flame retardant cables having excellent
physical and electrical properties are required. The cables have excellent resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these cables can be supplied
without the sheath over the armor. Cables are also available with either a fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed in the interstices.

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

3/c 15 kV (IEC 8.7/15 kV) Shielded - 100% Level 116


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
AWG/MCM

MHV3-15-2
MHV3-15-1
MHV3-15-1/0
MHV3-15-2/0
MHV3-15-3/0
MHV3-15-4/0
MHV3-15-262
MHV3-15-313
MHV3-15-373
MHV3-15-444
MHV3-15-535
MHV3-15-646
MHV3-15-777
MHV3-15-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Nominal
Cable Diameter

mm2

Stranding

Inches

mm

Inches

mm

Inches

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177

4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50

.110
.115
.120
.120
.130
.140
.140
.145
.150
.155
.165
.175
.185
.200

2.80
2.92
3.05
3.05
3.30
3.56
3.56
3.68
3.81
3.94
4.19
4.45
4.70
5.08

2.110
2.260
2.390
2.420
2.710
2.840
2.940
3.100
3.260
3.420
3.640
3.870
4.120
4.620

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

121

www.drakausa.com

mm

53.59
57.40
60.71
61.47
68.83
72.14
74.68
78.74
82.80
86.87
92.46
98.30
104.65
117.35

Approx. Weight
Lbs/Mft

2300
2790
3200
3370
4300
4900
5400
6100
6900
7900
9100
10600
12300
16600

kg/km

3423
4152
4643
5015
6399
7292
8036
9078
10268
11756
13542
15775
18304
24703

ISO9001
QSC3497
BG_MHV3-15_116_117_2_00

TYPE N JACKET 15KV

Application

Marine & Offshore


Product Specification J-128

IECIEEEUL
Conductor

BOSTRIG MHV3-15B CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Three Conductor Power (Type N Jacket)


15 kV - Shielded - 100% Level
Armored Only

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-128 and flame test in IEC 60332-3, cat
A, A/F.

Rating

Bostrig MHV3-15B single conductor 15,000 volt shielded cables are suitable for use in commercial marine applications, MODUs, and platforms where flame retardant cables having
excellent physical and electrical properties are required. The cables have excellent resistance to
oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with
either a fully insulated grounding conductor or an un-insulated grounding conductor evenly
distributed in the interstices.

3/c 15 kV Shielded - 100% Level 178


BIW
Cable Type
Conductor Size
AWG/MCM

MHV3-15B-2
MHV3-15B-1
MHV3-15B-l/0
MHV3-15B-2/0
MHV3-15B-3/0
MHV3-15B-4/0
MHV3-15B-262
MHV3-15B-313
MHV3-15B-373
MHV3-15B-444
MHV3-15B-535
MHV3-15B-646
MHV3-15B-777
MHV3-15B-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Insulation
Jacket
Wall Thickness Wall Thickness

Nominal
Cable Diameter

mm2

Stranding

Inches

mm

Inches

mm

Inches

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177

4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50

.110
.115
.120
.120
.130
.140
.140
.145
.150
.155
.165
.175
.185
.200

2.80
2.92
3.05
3.05
3.30
3.56
3.56
3.68
3.81
3.94
4.19
4.45
4.70
5.08

2.170
2.320
2.450
2.480
2.770
2.900
3.000
3.160
3.320
3.480
3.700
3.930
4.180
4.680

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

122

www.drakausa.com

mm

55.12
58.93
62.23
62.99
70.36
73.66
76.20
80.26
84.33
88.39
93.98
99.82
106.17
118.87

Approx. Weight
Lbs/Mft

2660
3200
3550
3800
4800
5400
5950
6700
7550
8550
9800
11300
13100
17500

kg/km

3959
4762
5283
5655
7143
8036
8855
9971
11236
12724
14584
16816
19495
26042

ISO9001
QSC3497
BG_MHV3-15B_178_2_00

TYPE N JACKET 15KV

Application

Marine & Offshore


Product Specification J-129

IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV3-15B CABLE

Conductor Shield

Three Conductor Power (Type N Jacket)


15 kV - Shielded - 133% Level
Armored Only

Semi-conducting tape with extruded thermosetting semi-conducting


EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-129 and flame test in IEC 60332-3, cat
A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Application
Bostrig MHV3-15B three conductor 15,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

3/c 15 kV Shielded - 133% Level 179


BIW
Cable Type
Conductor Size

TYPE N JACKET 15KV

AWG/MCM

MHV3-15B-2
MHV3-15B-1
MHV3-15B-1/0
MHV3-15B-2/0
MHV3-15B-3/0
MHV3-15B-4/0
MHV3-15B-262
MHV3-15B-313
MHV3-15B-373
MHV3-15B-444
MHV3-15B-535
MHV3-15B-646
MHV3-15B-777
MHV3-15B-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Insulation
Jacket
Wall Thickness Wall Thickness

Nominal
Cable Diameter

mm2

Stranding

Inches

mm

Inches

mm

Inches

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220

5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59

.115
.120
.125
.130
.140
.145
.145
.155
.160
.165
.170
.185
.190
.210

2.92
3.05
3.18
3.30
3.56
3.68
3.68
3.94
4.06
4.19
4.32
4.76
4.83
5.33

2.390
2.530
2.650
2.710
2.990
3.110
3.220
3.380
3.530
3.700
3.910
4.200
4.390
4.910

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

123

www.drakausa.com

mm

Approx. Weight
Lbs/Mft

60.71
64.26
67.31
68.83
75.95
78.99
81.78
85.85
89.66
93.98
99.31
106.68
111.51
124.71

3010
3550
3950
4250
5250
5850
6400
7200
8100
9100
10400
12100
13800
18200

kg/km

4479
5283
5878
6325
7813
8706
9525
10715
12054
13542
15477
18007
20536
27084

ISO9001
QSC3497
BG_MHV3-15B_179_2_00

Marine & Offshore


Product Specification J-129

IECIEEEUL
Conductor

BOSTRIG MHV3-15BS CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Three Conductor Power (Type N Jacket & Sheath)


15 kV (IEC 12/20 kV) Shielded - 133% Level
Armored and Sheathed

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the cabled core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-129, and flame test in
IEC 60332-3, cat A, A/F.

Application
Bostrig MHV3-15BS three conductor 15,000 volt shielded cables are suitable for use in commercial marine applications, MODUs, and platforms where flame retardant cables having
excellent physical and electrical properties are required. The cables have excellent resistance to
oils, abrasion, petrochemical fluids, moisture, and sunlight. When required these cables can be
supplied without the sheath over the armor. Cables are also available with either a fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed in the
interstices.

3/c 15 kV (IEC 12/20 kV) Shielded - 133% Level 119


BIW
Insulation
Cable Type
Conductor Size
Wall Thickness

TYPE N JACKET 15KV

AWG.MCM

MHV3-15BS-2
MHV3-15BS-1
MHV3-15BS-1/0
MHV3-15BS-2/0
MHV3-15BS-3/0
MHV3-15BS-4/0
MHV3-15BS-262
MHV3-15BS-313
MHV3-15BS-373
MHV3-15BS-444
MHV3-15BS-535
MHV3-15BS-646
MHV3-15BS-777
MHV3-15BS-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Jacket/Sheath
Wall Thickness

Nominal
Cable Diameter Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220
.220

5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59
5.59

.115/.110
.120/.110
.125/.140
.130/.140
.140/.140
.145/.140
.145/.140
.155/.140
.160/.140
.165/.140
.170/.140
.185/.140
.190/.140
.210/.140

2.92/2.80
3.05/2.80
3.18/3.56
3.30/3.56
3.56/3.56
3.68/3.56
3.68/3.56
3.94/3.56
4.06/3.56
4.19/3.56
4.32/3.56
4.76/3.56
4.83/3.56
5.33/3.56

2.600
2.750
2.930
2.970
3.260
3.380
3.480
3.650
3.810
3.970
4.180
4.470
4.670
5.190

66.04
69.85
74.42
75.44
82.85
85.85
88.39
92.71
96.77
100.84
106.17
113.54
118.62
131.83

3600
4150
4700
5000
6100
6750
7300
8150
9100
10200
11500
13300
15000
19600

5357
6176
6994
7441
9078
10045
10864
12129
13542
15180
17114
19793
22322
29168

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

124

www.drakausa.com

ISO9001
QSC3497
BG_MHV3-15_118_119_2_00

Marine & Offshore


Product Specification J-128

IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV3-15BS CABLE

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Three Conductor Power (Type N Jacket & Sheath)


15 kV (IEC 8.7/15 kV) Shielded - 100% Level
Armored and Sheathed

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the cabled core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-128, and
flame test in IEC 60332-3, cat A, A/F.

Rating

Application
Bostrig MHV3-15BS three conductor 15,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these
cables can be supplied without the sheath over the armor. Cables are also available with either
a fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed in the interstices.

3/c 15 kV (IEC 8.7/15 kV) Shielded - 100% Level 117


BIW
Insulation
Cable Type
Conductor Size
Wall Thickness

TYPE N JACKET 15KV

AWG.MCM

MHV3-15BS-2
MHV3-15BS-1
MHV3-15BS-1/0
MHV3-15BS-2/0
MHV3-15BS-3/0
MHV3-15BS-4/0
MHV3-15BS-262
MHV3-15BS-313
MHV3-15BS-373
MHV3-15BS-444
MHV3-15BS-535
MHV3-15BS-646
MHV3-15BS-777
MHV3-15BS-1111

2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Jacket/Sheath
Wall Thickness

Nominal
Cable Diameter Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177
.177

4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50

.110/.110
.115/.110
.120/.110
.120/.110
.130/.140
.140/.140
.140/.140
.145/.140
.150/.140
.155/.140
.165/.140
.175/.140
.185/.140
.200/.140

2.80/2.80
2.92/2.80
3.05/2.80
3.05/2.80
3.30/2.80
3.56/3.56
3.56/3.56
3.68/3.56
3.81/3.56
3.94/3.56
4.19/3.56
4.45/3.56
4.70/3.56
5.08/3.56

2.400
2.540
2.670
2.710
3.050
3.180
3.290
3.440
3.600
3.760
3.980
4.210
4.470
4.970

60.96
64.52
67.82
68.83
77.47
80.77
83.57
87.38
91.44
95.50
101.09
106.93
113.54
126.24

3150
3700
4100
4400
5600
6200
6800
7600
8500
9500
10800
12400
14300
18700

4688
5506
6102
6548
8334
9226
10120
11310
12649
14138
16072
18453
21281
27829

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

125

www.drakausa.com

ISO9001
QSC3497
BG_MHV3-15_116_117_2_00

TYPE N JACKET 5KV

Marine & Offshore


Product Specification J-125

IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV3-5 CABLE

Conductor Shield

Three Conductor Power (Type N Jacket)


5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level
Unarmored

Semi-conducting tape with extruded thermosetting semi-conducting


EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-125, and flame test in
IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Application
Bostrig MHV3-5 three conductor 5,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a fully insulated grounding conductor or an un-insulated grounding conductor
evenly distributed in the interstices.

3/c - 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level 110


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
MHV3-5-8
MHV3-5-6
MHV3-5-5
MHV3-5-4
MHV3-5-2
MHV3-5-1
MHV3-5-1/0
MHV3-5-2/0
MHV3-5-3/0
MHV3-5-4/0
MHV3-5-262
MHV3-5-313
MHV3-5-373
MHV3-5-444
MHV3-5-535
MHV3-5-646
MHV3-5-777
MHV3-5-1111

Nominal
Cable Diameter

AWG/MCM

mm2

Stranding

Inches

mm

Inches

mm

Inches

8
6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

7.57
12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

37/24
61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.090
.090
.090
.090
.090
.090
.090
.090
.095
.095
.095
.095
.095
.095
.095
.103
.103
.110

2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.60
2.60
2.80

.080
.085
.085
.090
.110
.110
.110
.110
.115
.120
.125
.130
.140
.145
.150
.160
.170
.190

2.03
2.16
2.16
2.29
2.80
2.80
2.80
2.80
2.92
3.05
3.18
3.30
3.56
3.68
3.81
4.06
4.32
4.83

1.300
1.430
1.510
1.580
1.750
1.880
1.990
2.030
2.280
2.400
2.520
2.720
2.880
3.040
3.260
3.520
3.730
4.320

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

126

www.drakausa.com

mm

33.02
36.32
38.35
40.13
44.45
47.75
50.55
51.56
57.91
60.96
64.01
69.09
73.15
77.22
82.55
89.41
94.74
109.73

Approx. Weight
Lbs/Mft

850
1070
1260
1380
1730
2160
2450
2700
3500
4000
4500
5300
6100
7000
8050
9600
11200
15600

kg/km

1265
1592
1875
2054
2575
3214
3646
4018
5210
5953
6697
7887
9078
10417
11980
14286
16667
23215

ISO9001
QSC3497
BG_MHV3-5_110_111_2_00

TYPE N JACKET 5KV

Marine & Offshore


Product Specification J-125

IECIEEEUL

BOSTRIG MHV3-5B CABLE

Conductor

Three Conductor Power (Type N Jacket)


5 kV - Shielded - 100% or 133% Level
Armored Only

Soft annealed tinned copper.


Stranding as shown in table below.

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Application
Bostrig MHV3-5B three conductor 5,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a fully insulated grounding conductor or an un-insulated grounding conductor
evenly distributed in the interstices.

Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),


ICEA S-68-5I6, UL 1072, J-125 and flame test in IEC 60332-3, cat
A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

3/c - 5 kV Shielded - 100% or 133% Level 175


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
MHV3-5B-8
MHV3-5B-6
MHV3-5B-5
MHV3-5B-4
MHV3-5B-2
MHV3-5B-1
MHV3-5B-1/0
MHV3-5B-2/0
MHV3-5B-3/0
MHV3-5B-4/0
MHV3-5B-262
MHV3-5B-313
MHV3-5B-373
MHV3-5B-444
MHV3-5B-535
MHV3-5B-646
MHV3-5B-777
MHV3-5B-1111

Nominal
Cable Diameter

Approx. Weight

AWG/MCM

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

8
6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

7.57
12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

37/24
61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.090
.090
.090
.090
.090
.090
.090
.090
.095
.095
.095
.095
.095
.095
.095
.103
.103
.110

2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.60
2.60
2.80

.080
.085
.085
.090
.110
.110
.110
.110
.115
.120
.125
.130
.140
.145
.150
.160
.170
.190

2.03
2.16
2.16
2.29
2.80
2.80
2.80
2.80
2.92
3.06
3.18
3.30
3.56
3.68
3.81
4.06
4.32
4.83

1.360
1.490
1.570
1.640
1.810
1.940
2.050
2.080
2.340
2.460
2.580
2.780
2.940
3.100
3.320
3.580
3.790
4.380

34.54
37.85
39.88
41.66
45.97
49.28
52.07
52.83
59.44
62.48
65.53
70.61
74.68
78.74
84.33
90.93
96.27
111.25

1090
1330
1530
1670
2030
2500
2800
3050
3900
4450
5000
5800
6600
7550
8750
10300
11900
16400

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

127

www.drakausa.com

kg/km

1622
1980
2276
2485
3021
3721
4167
4539
5804
6622
7441
8631
9822
11236
13021
15328
17709
24406

ISO9001
QSC3497
BG_MHV3-5B_175_2_00

Product Specification J-125

IECIEEEUL

BOSTRIG MHV3-5BS CABLE

Conductor

Three Conductor Power (Type N Jacket & Sheath)


5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level
Armored and Sheathed

Soft annealed tinned copper.


Stranding as shown in table below.

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the cable core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Application
Bostrig MHV3-5BS three conductor 5,000 volt shielded cables are suitable for use in
commercial marinc applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these
cables can be supplied without the sheath over the armor. Cables are also available with either a
fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed in
the interstices.

Meets applicable test requirements in IEC 60502, IEEE 45-1998 &


1993 (draft), ICEAS-68-516, UL 1072, J-125, and flame test in
IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

3/c - 5 kV (IEC 1.8/3 kV) Shielded - l00% or 133% Level 111


BIW
Insulation
Jacket/Sheath
Cable Type
Conductor Size
Wall Thickness Wall Thickness
MHV3-5BS-8
MHV3-5BS-6
MHV3-5BS-5
MHV3-5BS-4
MHV3-5BS-2
MHV3-5BS-l
MHV3-5BS-l/0
MHV3-5BS-2/0
MHV3-5BS-3/0
MHV3-5BS-4/0
MHV3-5BS-262
MHV3-5BS-313
MHV3-5BS-373
MHV3-5BS-444
MHV3-5BS-535
MHV3-5BS-646
MHV3-5BS-777
MHV3-5BS-1111

Nominal
Cable Diameter Approx. Weight

AWG.MCM

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

8
6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

7.57
12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

37/24
61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.090
.090
.090
.090
.090
.090
.090
.090
.095
.095
.095
.095
.095
.095
.095
.103
.103
.110

2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.29
2.40
2.40
2.40
2.40
2.40
2.40
2.40
2.60
2.60
2.80

.080/.080
.085/.080
.085/.110
.090/.110
.110/.110
.110/.110
.110/.110
.110/.110
.115/.110
.120/.110
.125/.110
.130/.140
.140/.140
.145/.140
.150/.140
.160/.140
.170/.140
.190/.140

2.03/2.03
2.16/2.03
2.16/2.80
2.29/2.80
2.80/2.80
2.80/2.80
2.80/2.80
2.80/2.80
2.92/2.80
3.05/2.80
3.18/2.80
3.30/3.56
3.56/3.56
3.68/3.56
3.81/3.56
4.06/3.56
4.32/3.56
4.83/3.56

1.520
1.650
1.800
1.870
2.030
2.160
2.280
2.320
2.560
2.680
2.860
3.060
3.220
3.380
3.590
3.860
4.070
4.660

38.61
41.91
45.72
47.54
51.56
54.86
57.91
58.93
65.02
68.07
72.64
77.72
81.79
85.85
91.19
98.04
103.38
118.36

1350
1600
1900
2050
2450
2950
3300
3550
4450
5000
5700
6600
7450
8450
9700
11300
13000
17600

2009
2381
2828
3051
3646
4390
4911
5283
6622
7441
8483
9822
11087
12575
14435
16816
19346
26192

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

128

www.drakausa.com

ISO9001
QSC3497
BG_MHV3-5_110_111_2_00

TYPE N JACKET 5KV

Marine & Offshore

Marine & Offshore


Product Specification J-126

IECIEEEUL
Conductor

BOSTRIG MHV3-8 CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Three Conductor Power (Type N Jacket)


8 kV (IEC 3.6/6 kV) Shielded - 100% Level
Unarmored

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-126, and
flame test in IEC 60332-3, cat A, A/F.
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Application
Bostrig MHV3-8 three conductor 8,000 volt shielded cables are suitable for use in commercial
marine applications, MODUs, and platforms where flame retardant cables having excellent
physical and electrical properties are required. The cables have excellent resistance to oils,
abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a
fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed
in the interstices.

3/c - 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 112


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
AWG/MCM

MHV3-8-6
MHV3-8-5
MHV3-8-4
MHV3-8-2
MHV3-8-1
MHV3-8-1/0
MHV3-8-2/0
MHV3-8-3/0
MHV3-8-4/0
MHV3-8-262
MHV3-8-313
MHV3-8-373
MHV3-8-444
MHV3-8-535
MHV3-8-646
MHV3-8-777
MHV3-8-1111

6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Nominal
Cable Diameter

Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.126

3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.20

.090
.090
.095
.110
.110
.110
.110
.120
.125
.130
.140
.145
.145
.155
.165
.170
.195

2.29
2.29
2.40
2.80
2.80
2.80
2.80
3.05
3.18
3.30
3.56
3.56
3.68
3.94
4.19
4.32
4.95

1.570
1.650
1.710
1.870
2.000
2.110
2.150
2.400
2.510
2.630
2.830
2.990
3.150
3.360
3.590
3.800
4.400

39.88
41.91
43.43
47.50
50.80
53.59
54.61
60.96
63.75
66.80
71.88
75.95
80.01
85.34
91.19
96.52
111.76

1230
1420
1560
1890
2340
2640
3900
3700
4200
4700
5550
6300
7250
8450
9850
11400
15850

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

129

www.drakausa.com

kg/km

1830
2113
2322
2813
3482
3929
4316
5506
6250
6994
8259
9375
10789
12575
14658
16965
23587

ISO9001
QSC3497
BG_MHV3-8_112_113_2_00

TYPE N JACKET 8KV

Rating

Marine & Offshore


Product Specification J-127

IECIEEEUL
Conductor

BOSTRIG MHV3-8 CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Three Conductor Power (Type N Jacket)


8 kV (IEC 6/10 kV) Shielded - 133% Level
Unarmored

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
Ajacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core.
Thickness as shown in table below.

Tests

Rating
Application
Bostrig MHV3-8 three conductor 8,000 volt shielded cables are suitable for use in commercial
marine applications, MODUs, and platforms where flame retardant cables having excellent
physical and electrical properties are required. The cables have excellent resistance to oils,
abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a
fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed
in the interstices.

Listed by a Nationally Recognized Testing Lab (ETL) in conformance


to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
approved by DNV, ABS and LRS.

3/c - 8 kV (IEC 6/10 kV) Shielded - 133% Level 114


BIW
Insulation
Jacket
Cable Type
Conductor Size
Wall Thickness Wall Thickness
AWG/MCM

MHV3-8-5
MHV3-8-4
MHV3-8-2
MHV3-8-1
MHV3-8-1/0
MHV3-8-2/0
MHV3-8-3/0
MHV3-8-4/0
MHV3-8-262
MHV3-8-313
MHV3-8-373
MHV3-8-444
MHV3-8-535
MHV3-8-646
MHV3-8-777
MHV3-8-1111

5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Nominal
Cable Diameter

mm2

Stranding

Inches

mm

Inches

mm

Inches

18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140

3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56

.110
.110
.110
.110
.115
.115
.125
.125
.135
.140
.145
.150
.160
.165
.175
.195

2.80
2.80
2.80
2.80
2.92
2.92
3.18
3.18
3.43
3.56
3.68
3.81
4.06
4.19
4.45
4.95

1.780
1.840
1.960
2.100
2.210
2.250
2.500
2.610
2.780
2.930
3.090
3.250
3.470
3.690
3.950
4.460

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

130

www.drakausa.com

mm

45.21
46.74
49.78
53.34
56.13
57.15
63.50
66.29
70.61
74.42
78.49
82.55
88.14
93.73
100.33
113.28

Approx. Weight
Lbs/Mft

1610
1730
2030
2470
2790
3040
3870
4380
5000
5750
6550
7500
8700
10100
11800
16100

kg/km

2396
2575
3021
3676
4152
4524
5759
6518
7440
8557
9748
11161
12947
15030
17560
23959

ISO9001
QSC3497
BG_MHV3-8_114_115_2_00

TYPE N JACKET 8KV

Meets applicable test requirements in IEC 60502, IEC 60092-354,


IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-127, and
flame test in IEC 60332-3, cat A, A/F.

Marine & Offshore


Product Specification J-126

IECIEEEUL
Conductor

BOSTRIG MHV3-8B CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Three Conductor Power (Type N Jacket)


8 kV - Shielded - 100% Level
Armored Only

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core.
Thickness as shown in table below.

Armor
Braided Bronze.
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-126 and flame test in IEC 60332-3, cat A,
A/F.

Application
Bostrig MHV3-8B three conductor 8,000 volt shielded cables are suitable for use in commercial marine applications, MODUs, and platforms where flame retardant cables having excellent physical and electrical properties are required. The cables have excellent resistance to oils,
abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a
fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed
in the interstices.

3/c - 8 kV Shielded - 100% Level 176


BIW
Cable Type
Conductor Size
AWG/MCM

MHV3-8B-6
MHV3-8B-5
MHV3-8B-4
MHV3-8B-2
MHV3-8B-1
MHV3-8B-1/0
MHV3-8B-2/0
MHV3-8B-3/0
MHV3-8B-4/0
MHV3-8B-262
MHV3-8B-313
MHV3-8B-373
MHV3-8B-444
MHV3-8B-535
MHV3-8B-646
MHV3-8B-777
MHV3-8B-1111

6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance
to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
approved by DNV, ABS and LRS.

Insulation
Jacket
Wall Thickness Wall Thickness

Nominal
Cable Diameter

Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.126

3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.20

.090
.090
.095
.110
.110
.110
.110
.120
.125
.130
.140
.140
.145
.155
.165
.170
.195

2.29
2.29
2.40
2.80
2.80
2.80
2.80
3.05
3.18
3.30
3.56
3.56
3.68
3.94
4.19
4.32
4.95

1.630
1.710
1.770
1.930
2.060
2.170
2.210
2.460
2.570
2.690
2.890
3.050
3.210
3.420
3.650
3.860
4.460

41.40
43.43
44.93
49.02
52.32
55.12
56.13
62.48
65.28
68.32
73.41
77.47
81.53
86.87
92.71
98.04
113.28

1510
1720
1870
2250
2700
3050
3300
4150
4700
5200
6050
6850
7800
9050
10500
12100
16700

kg/km

2247
2560
2783
3348
4018
4539
4911
6176
6994
7738
9003
10194
11607
13468
15626
18007
24852

DRAKA-USA

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

131

www.drakausa.com

ISO9001
QSC3497
BG_MHV3-8B_176_2_00

TYPE N JACKET 8KV

Tests

Marine & Offshore


Product Specification J-121

IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV3-8B CABLE

Conductor Shield

Three Conductor Power (Type N Jacket)


8 kV - Shielded - 133% Level
Armored Only

Semi-conducting tape with extruded thermosetting semi-conducting


EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.

Armor
Braided Bronze.

TYPE N JACKET 8KV

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-127 and flame test in IEC 60332-3, cat
A, A/F.

Rating
Application
Bostrig MHV3-8B single conductor 8,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a fully insulated grounding conductor or an un-insulated grounding conductor
evenly distributed in the interstices.

3/c 8 kV Shielded - 133% Level 177


BIW
Cable Type
Conductor Size
AWG/MCM

MHV3-8B-5
MHV3-8B-4
MHV3-8B-2
MHV3-8B-1
MHV3-8B-1/0
MHV3-8B-2/0
MHV3-8B-3/0
MHV3-8B-4/0
MHV3-8B-262
MHV3-8B-313
MHV3-8B-373
MHV3-8B-444
MHV3-8B-535
MHV3-8B-646
MHV3-8B-777
MHV3-8B-1111

5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

Insulation
Jacket
Wall Thickness Wall Thickness

Nominal
Cable Diameter

mm2

Stranding

Inches

mm

Inches

mm

Inches

18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140

3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56

.110
.110
.110
.110
.115
.115
.125
.125
.135
.140
.145
.150
.160
.165
.175
.195

2.80
2.80
2.80
2.80
2.92
2.92
3.18
3.18
3.43
3.56
3.68
3.81
4.06
4.19
4.45
4.95

1.840
1.900
2.020
2.160
2.270
2.310
2.560
2.670
2.840
2.990
3.150
3.310
3.530
3.750
4.010
4.520

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

132

www.drakausa.com

mm

Approx. Weight
Lbs/Mft

46.74
48.26
51.31
54.87
57.66
58.68
65.03
67.82
82.14
75.95
80.01
84.07
89.66
95.25
101.85
114.81

1930
2060
2380
2850
3200
3500
4350
4900
5550
6300
7100
8100
9350
10800
12600
16900

kg/km

2872
3066
3542
4241
4762
5209
6473
7292
8259
9375
10566
12054
13914
16072
18751
25150

ISO9001
QSC3497
BG_MHV3-8B_177_2_00

Marine & Offshore


Product Specification J-126

IECIEEEUL
Conductor

BOSTRIG MHV3-8BS CABLE

Soft annealed tinned copper.


Stranding as shown in table below.

Three Conductor Power (Type N Jacket & Sheath)


8 kV (IEC 3.6/6 kV) Shielded - 100% Level
Armored and Sheathed

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the cabled core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze.

TYPE N JACKET 8KV

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-126, and
flame test in IEC 60332-3, cat A, A/F.

Application
Bostrig MHV-8BS three conductor 8,000 volt shielded cables are suitable for use in commercial marine applications, MODUs, and platforms where flame retardant cables having excellent physical and electrical properties are required. The cables have excellent resistance to oils,
abrasion, petrochemical fluids, moisture, and sunlight. When required, these cables can be
supplied without the sheath over the armor. Cables are also available with either a fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed in the
interstices.

3/c - 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 113


BIW
Insulation
Cable Type
Conductor Size
Wall Thickness
AWG.MCM

MHV3-8BS-6
MHV3-8BS-5
MHV3-8BS-4
MHV3-8BS-2
MHV3-8BS-1
MHV3-8BS-1/0
MHV3-8BS-2/0
MHV3-8BS-3/0
MHV3-8BS-4/0
MHV3-8BS-262
MHV3-8BS-313
MHV3-8BS-373
MHV3-8BS-444
MHV3-8BS-535
MHV3-8BS-646
MHV3-8BS-777
MHV3-8BS-1111

6
5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001.
Type approved by DNV, ABS and LRS.

Jacket/Sheath
Wall Thickness

Nominal
Cable Diameter Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

12.5
18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

61/24
91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.118
.126

3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.00
3.20

.090/.110
.090/.110
.095/.110
.110/.110
.110/.110
.110/.110
.110/.110
.120/.110
.125/.140
.130/.140
.140/.140
.140/.140
.145/.140
.155/.140
.165/.140
.170/.140
.195/.140

2.29/2.80
2.29/2.80
2.40/2.80
2.80/2.80
2.80/2.80
2.80/2.80
2.80/2.80
3.05/2.80
3.18/3.56
3.30/3.56
3.56/3.56
3.56/3.56
3.68/3.56
3.94/3.56
4.19/3.56
4.32/3.56
4.95/3.56

1.840
1.920
1.990
2.140
2.280
2.400
2.430
2.670
2.850
2.970
3.170
3.320
3.480
3.700
3.940
4.140
4.740

46.74
48.77
50.55
54.36
57.91
60.96
61.72
67.82
72.39
75.44
80.52
84.33
88.39
93.98
100.08
105.16
120.40

1900
2100
2280
2680
3180
3520
3800
4700
5400
6000
6900
7700
8700
10000
11500
13200
17900

2828
3125
3393
3988
4732
5238
5655
6994
8036
8929
10268
11459
12947
14881
17114
19644
26638

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

133

www.drakausa.com

ISO9001
QSC3497
BG_MHV3-8_112_113_2_00

Marine & Offshore


Product Specification J-127

IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.

BOSTRIG MHV3-8BS CABLE


Three Conductor Power (Type N Jacket & Sheath)
8 kV (IEC 6/10 kV) Shielded - 133% Level
Armored and Sheathed

Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the cabled core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze.

TYPE N JACKET 8KV

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-127, and
flame test in IEC 60332-3, cat A/F.

Application

Rating

Bostrig MHV-8BS three conductor 8,000 volt shielded cables are suitable for use in commercial marine applications, MODUs, and platforms where flame retardant cables having excellent physical and electrical properties are required. The cables have excellent resistance to oils,
abrasion, petrochemical fluids, moisture, and sunlight. When required, these cables can be supplied without the sheath over the armor. Cables are also available with either a fully insulated
grounding conductor or an un-insulated grounding conductor evenly distributed in the interstices.

Listed by a Nationally Recognized Testing Lab (ETL) in conformance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 15802001. Type approved by DNV, ABS and LRS.

3/c - 8 kV (IEC 6/10 kV) Shielded - 133% Level 115


BIW
Insulation
Cable Type
Conductor Size
Wall Thickness
AWG.MCM

MHV3-8BS-5
MHV3-8BS-4
MHV3-8BS-2
MHV3-8BS-1
MHV3-8BS-1/0
MHV3-8BS-2/0
MHV3-8BS-3/0
MHV3-8BS-4/0
MHV3-8BS-262
MHV3-8BS-313
MHV3-8BS-373
MHV3-8BS-444
MHV3-8BS-535
MHV3-8BS-646
MHV3-8BS-777
MHV3-8BS-1111

5
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
1111

Jacket/Sheath
Wall Thickness

Nominal
Cable Diameter Approx. Weight

mm2

Stranding

Inches

mm

Inches

mm

Inches

mm

Lbs/Mft

kg/km

18.6
21.5
30.7
46.0
56.3
66.5
92.1
112.6
133.0
158.6
189.3
225.1
271.2
327.5
393.8
562.8

91/24
105/24
150/24
225/24
275/24
325/24
450/24
550/24
650/24
775/24
925/24
1100/24
1325/24
1600/24
1925/24
2750/24

.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140
.140

3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56
3.56

.110/.110
.110/.110
.110/.110
.110/.110
.115/.110
.115/.110
.125/.140
.125/.140
.135/.140
.140/.140
.145/.140
.150/.140
.160/.140
.165/.140
.175/.140
.195/.140

2.80/2.80
2.80/2.80
2.80/2. 80
2.80/2.80
2.92/2.80
2.92/2.80
3.18/3.56
3.18/3.56
3.43/3.56
3.56/3.56
3.68/3.56
3.81/3.56
4.06/3.56
4.19/3.56
4.45/356
4.95/3.56

2.060
2.120
2.240
2.380
2.500
2.540
2.840
2.950
3.100
3.270
3.440
3.600
3.810
4.030
4.280
4.800

52.32
5.85
56.90
60.45
63.50
64.52
72.14
74.93
78.99
83.06
87.38
91.44
96.77
102.36
108.71
121.92

2350
2510
2860
3350
3730
4000
5100
5650
6350
7150
8000
9000
10350
11800
13700
18200

3497
3735
4256
4985
5550
5953
7590
8408
9450
10640
11905
13393
15402
17560
20388
27084

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857

134

www.drakausa.com

ISO9001
QSC3497
BG_MHV3-8_114_115_2_00

Bostrig Type P
0807
Page 53 of 62

S611T MARINE FIBER OPTIC CABLES


Tight buffer construction

2 to 48 fibers /
singlemode or multimode /
LSZH
1

Applications
The Drake S611T series of Marine and Offshore fiber optic cables is designed especially for the harsh environments of
commercial marine vessels, oil platforms and other similar applications.
Draka S611T low smoke/zero halogen, flame retardant cables offer the versatility and ease of use of our other offshore
cables in a construction suited for marine applications. They are compliant with the latest IEC requirements.
S611T cables meet the requirements of IEC 60793-1 and IEC 60793-2 specifications, are encapsulated in all dielectric,
tight buffered construction, individuall reinforced with aramid yarns and jacketed (breakout style). The breakout
components are cabled around a central member providing additonal tensile strength to the entire construction.
The thermoplastic low smoke/zero halogen jacketing system offers good resistance to chemicals, fluids, fungus, and
abrasion.
This product is readily available in an armored version.

Construction
1. Central Strength Member
2. Fiber
3. Subunit Strength Member
4. Subunit Jacket
5. Sheath

Dielectric material (epoxy fiberglass rod).


Multimode or singlemode fibers with an easily-strippable 900m tight buffering colored
per TIA/EIA 598.
Aramid yarn
ChromaTek-L Halex low smoke zero halogen polyolefin.
ChromaTek-L Halex low smoke zero halogen polyolefin.

Features
Low smoke/zero halogen construction meets appropriate IEEE and IEC standards
for fire, smoke, and toxicity
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Gigabit Ethernet 802.3Z compliant

Ratings
Meets IEC 60794-1-1, 60794-1-2 and 60794-2.
Det Norske Veritas Type Approval Certificate E-7154.
American Bureau of Shipping Approval Certificate 04-HS440499B/2-PDA.
Lloyds Registry of Shipping Approval Certificate 00/00157E2.
Flame retardant per IEC 60332-3, CAT. A CAT A/F and IEEE 1202
Smoke density requirements of IEC 61034-1 and IEC 61034-2
Acid gas generation requirements of IEC 60754-1 and IEC 60754-2
Toxicity requirements of NES 713
Meets the performance requirements of IEEE 802.3z (Gigabit Ethernet)

www.DrakaMOG.com
DUSA_MOG53_0807

Subject to change without prior notice

135

Bostrig Type P
0807
Page 54 of 62

S611T MARINE FIBER OPTIC CABLES


tight buffer construction
2 to 48 fibers / singlemode or multimode / LSZH
INSTALLATION

OPERATING

Tension
Newtons (lbs)

Bend Radius
cm (in)

Cable O.D.
mm (in)

Approximate
Cable Weight
Kg/km (Lbs/mft)

12.8 (5.0)

200 (45)

6.4 (2.5)

6.4 (.252)

45 (30)

14.6 (5.8

200 (45)

7.3 (2.9)

7.3 (.287)

51 (35)

600 (135)

17.0 (6.8)

200 (45)

8.5 (3.4)

8.5 (.335)

71 (48)

600 (135)

19.4 (7.6)

200 (45)

9.7 (3.8)

9.7 (.381)

93 (63)

S611T-10-xxy

10

600 (135)

22.0 (8.4)

200 (45)

11.0 (4.3)

11.0 (.431)

119 (80)

S611T-12-xxy

12

600 (135)

24.4 (9.6)

200 (45)

12.2 (4.8)

12.2 (.481)

149 (100)

S611T-16-xxy

16

2700 (600)

25.7 (10.2)

600 (135)

12.8 (5.1)

12.8 (.507)

150 (101)

S611T-18-xxy

18

2700 (600)

25.7 (10.2)

600 (135)

12.8 (5.1)

12.8 (.507)

148 (100)

S611T-24-xxy

24

2700 (600)

29.6 (11.6)

600 (135)

14.8 (5.8)

14.8 (.581)

356 (238)

S611T-36-xxy

36

2700 (600)

34.0 (13.4)

600 (135)

17.0 (6.7)

17.0 (.670)

484 (325)

S611T-48-xxy

48

2700 (600)

46.0 (18.1)

600 (135)

23.1 (9.1)

23.0 (.905)

600 (403)

DRAKA USA
Part Number

Number
of Fibers

Pull Strength
Newtons (lbs)

Bend Radius
cm (in)

S611T-02R-xxy

600 (135)

S611T-04-xxy

600 (135)

S611T-06-xxy

S611T-08-xxy

Replace the xxy with the Fiber Designation in the fiber performance table below.
NOTE: Fibers are not suitable for F07 crimp and cleave connector.
Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications.

FIBER PERFORMANCE
62.5m MULTIMODE

50 m MULTIMODE

200m MULTIMODE

8.3m SINGLEMODE

Fiber Designation

62X

50H

200S

010X

Applicable Specification

IEC 60793-2 Type A1b

ITU G.651 & IEC 60793-2 Type A1a


& IEC 60793-2 Type B1.1

ITU G.651 & IEC 60793-2 Type A1a ITU G.652 Table C & D Requirements

Fiber Type

Graded Index

Graded Index

Step Index

Matched Clad

Core Diameter

62.5m 2.5m

50m 2.5m

200m 5m

8.3m Nominal

Cladding Diameter

125m 1m

125m 1m

230m 10m

125m 1m

Coating Diameter

242m 7m

242m 7m

500m 30m

242m 7m

Buffer Diameter

900m 50m

50m 2.5m

900m 50m

900m 50m

Numerical Aperture

0.275 0.015

0.200 0.015

.037 Nominal (2m 5% intensity)

N/A

Mode Field Diameter


Attenuation

N/A
3.5 dB/Km @ 850nm
1.0 dB/Km @ 1300nm

N/A
3.5 dB/Km @ 850nm
1.0 dB/Km @ 1300nm

N/A
12.0 dB/Km @ 820nm

9.1m 0.4m
0.70 dB/Km @ 1310nm
0.70 dB/Km @ 1550nm

Bandwidth

200 MHz/Km @ 850nm 500 MHz/Km @ 850nm


500 MHz/Km @ 1300nm 500 MHz/Km @ 1300nm

20 MHz/Km @ 820nm

N/A
N/A

Dispersion

N/A
N/A

N/A
N/A

N/A
N/A

3.0 ps/nm-Km @1285-1330nm


18 ps/nm-Km @ 1550nm

Proof Test

100,000 psi

100,000 psi

100,000 psi

100,000 psi

CABLE PROPERTIES
Crush (IEC 60794-1-E3)
Impact (IEC 60794-1-E4)
Torsion (IEC 60794-1-E7)
Cable Bend (IEC 60794-1-E11)

3000 N/ 10 cm
20 impacts, 5J
+ 1 turn / 2 m, 100 cycles
<0.1 dB/ + 6 turns

TEMPERATURE RANGE
Operation
Installation
Storage

-20C to +80C
-10C to +60C
-40C to +80C

FIRE, SMOKE, AND TOXICITY CLASSIFICATIONS


Flame retardant
IEC 60332-3, CAT.A CAT A/F and IEEE 1202
Smoke density
IEC 61034-1 and IEC 61034-2
Acid gas penetration
IEC 60754-1 and IEC 60754-2
Toxicity
NES 713

www.DrakaMOG.com
DUSA_MOG54_0807

Subject to change without prior notice

136

Bostrig Type P
0807
Page 55 of 62

S670T ARMORED AND SHEATHED MARINE FIBER OPTIC CABLES


Tight buffer construction

2 to 48 fibers /
singlemode or multimode /
LSZH / Armored & Sheathed

Applications
The Drake S670T series of Marine and Offshore fiber optic cables is designed especially for the harsh environments of
commercial marine vessels, oil platforms and other similar applications.
Draka S670T low smoke/zero halogen, flame retardant cables offer the versatility and ease of use of our other offshore
cables in a construction suited for marine applications. They are compliant with the latest IEC requirements.
S670T cables meet the requirements of IEC 60793-1 and IEC 60793-2 specifications, are encapsulated in all dielectric,
tight buffered construction, individuall reinforced with aramid yarns and jacketed (breakout style). The breakout
components are cabled around a central member providing additonal tensile strength to the entire construction.
The thermoplastic low smoke/zero halogen jacketing system offers good resistance to chemicals, fluids, fungus, and
abrasion.
This product is readily available in a non-armored version.

Construction
1. Central Strength Member
2. Fiber
3. Subunit Strength Member
4. Subunit Jacket
5. Jacket
6. Armor
7. Sheath

Dielectric material (epoxy fiberglass rod).


Multimode or singlemode fibers with an easily-strippable 900m tight buffering colored
per TIA/EIA 598.
Aramid yarn
ChromaTek-L Halex low smoke zero halogen polyolefin.
ChromaTek-L Halex low smoke zero halogen polyolefin.
Braided bronze in accordance with IEEE 1580 (2001).
ChromaTek-L Halex low smoke zero halogen polyolefin.

Features
Low smoke/zero halogen construction meets appropriate IEEE and IEC standards
for fire, smoke, and toxicity
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Gigabit Ethernet 802.3Z compliant

Ratings
Meets IEC 60794-1-1, 60794-1-2 and 60794-2.
Det Norske Veritas Type Approval Certificate E-7155.
American Bureau of Shipping Approval Certificate 04-HS440499B/2-PDA.
Lloyds Registry of Shipping Approval Certificate 00/00157E2.
Flame retardant per IEC 60332-3, CAT. A CAT A/F and IEEE 1202
Smoke density requirements of IEC 61034-1 and IEC 61034-2
Acid gas generation requirements of IEC 60754-1 and IEC 60754-2
Toxicity requirements of NES 713
Meets the performance requirements of IEEE 802.3z (Gigabit Ethernet)

www.DrakaMOG.com
DUSA_MOG55_0807

Subject to change without prior notice

137

Bostrig Type P
0807
Page 54
56 of 62

S670T ARMORED
S611TAND
MARINE
SHEATHED
FIBER
MARINE
OPTICFIBER
CABLES
OPTIC CABLES
tight buffer construction
2 to 48
fibers/ /singlemode
singlemodeorormultimode
multimode/ /LSZH
LSZH
4 fibers
INSTALLATION

OPERATING

Tension
Newtons (lbs)

Bend Radius
cm (in)

Cable O.D.
mm (in)

Approximate
Cable Weight
Kg/km (Lbs/mft)

12.8 (5.0)

200 (45)

6.4 (2.5)

6.4 (.252)

45 (30)

14.6 (5.8

200 (45)

7.3 (2.9)

7.3 (.287)

51 (35)

600 (135)

17.0 (6.8)

200 (45)

8.5 (3.4)

8.5 (.335)

71 (48)

600 (135)

19.4 (7.6)

200 (45)

9.7 (3.8)

9.7 (.381)

93 (63)

S607T-10-xxy
S611T-10-xxy

10

600 (135)

22.0 (8.4)

200 (45)

11.0 (4.3)

11.0 (.431)

119 (80)

S607T-12-xxy
S611T-12-xxy

12

600 (135)

24.4 (9.6)

200 (45)

12.2 (4.8)

12.2 (.481)

149 (100)

S607T-16-xxy
S611T-16-xxy

16

2700 (600)

25.7 (10.2)

600 (135)

12.8 (5.1)

12.8 (.507)

150 (101)

S607T-18-xxy
S611T-18-xxy

18

2700 (600)

25.7 (10.2)

600 (135)

12.8 (5.1)

12.8 (.507)

148 (100)

S607T-24-xxy
S611T-24-xxy

24

2700 (600)

29.6 (11.6)

600 (135)

14.8 (5.8)

14.8 (.581)

356 (238)

S607T-36-xxy
S611T-36-xxy

36

2700 (600)

34.0 (13.4)

600 (135)

17.0 (6.7)

17.0 (.670)

484 (325)

S607T-48-xxy
S611T-48-xxy

48

2700 (600)

46.0 (18.1)

600 (135)

23.1 (9.1)

23.0 (.905)

600 (403)

DRAKA USA
Part Number

Number
of Fibers

Pull Strength
Newtons (lbs)

Bend Radius
cm (in)

S607T-02R-xxy
S611T-02R-xxy

600 (135)

S607T-04-xxy
S611T-04-xxy

600 (135)

S607T-06-xxy
S611T-06-xxy

S607T-08-xxy
S611T-08-xxy

Replace the xxy with the Fiber Designation in the fiber performance table below.
NOTE: Fibers are not suitable for F07 crimp and cleave connector.
Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications.

FIBER PERFORMANCE
62.5m MULTIMODE

50 m MULTIMODE

200m MULTIMODE

8.3m SINGLEMODE

Fiber Designation

62X

50H

200S

010X

Applicable Specification

IEC 60793-2 Type A1b

ITU G.651 & IEC 60793-2 Type A1a


& IEC 60793-2 Type B1.1

ITU G.651 & IEC 60793-2 Type A1a ITU G.652 Table C & D Requirements

Fiber Type

Graded Index

Graded Index

Step Index

Matched Clad

Core Diameter

62.5m 2.5m

50m 2.5m

200m 5m

8.3m Nominal

Cladding Diameter

125m 1m

125m 1m

230m 10m

125m 1m

Coating Diameter

242m 7m

242m 7m

500m 30m

242m 7m

Buffer Diameter

900m 50m

50m 2.5m

900m 50m

900m 50m

Numerical Aperture

0.275 0.015

0.200 0.015

.037 Nominal (2m 5% intensity)

N/A

Mode Field Diameter


Attenuation

N/A
3.5 dB/Km @ 850nm
1.0 dB/Km @ 1300nm

N/A
3.5 dB/Km @ 850nm
1.0 dB/Km @ 1300nm

N/A
12.0 dB/Km @ 820nm

9.1m 0.4m
0.70 dB/Km @ 1310nm
0.70 dB/Km @ 1550nm

Bandwidth

200 MHz/Km @ 850nm 500 MHz/Km @ 850nm


500 MHz/Km @ 1300nm 500 MHz/Km @ 1300nm

20 MHz/Km @ 820nm

N/A
N/A

Dispersion

N/A
N/A

N/A
N/A

N/A
N/A

3.0 ps/nm-Km @1285-1330nm


18 ps/nm-Km @ 1550nm

Proof Test

100,000 psi

100,000 psi

100,000 psi

100,000 psi

CABLE PROPERTIES
Crush (IEC 60794-1-E3)
Impact (IEC 60794-1-E4)
Torsion (IEC 60794-1-E7)
Cable Bend (IEC 60794-1-E11)

3000 N/ 10 cm
20 impacts, 5J
+ 1 turn / 2 m, 100 cycles
<0.1 dB/ + 6 turns

TEMPERATURE RANGE
Operation
Installation
Storage

-20C to +80C
-10C to +60C
-40C to +80C

FIRE, SMOKE, AND TOXICITY CLASSIFICATIONS


Flame retardant
IEC 60332-3, CAT.A CAT A/F and IEEE 1202
Smoke density
IEC 61034-1 and IEC 61034-2
Acid gas penetration
IEC 60754-1 and IEC 60754-2
Toxicity
NES 713

www.DrakaMOG.com
DUSA_MOG56_0807
DUSA_MOG54_0807

Subject to change without prior notice

138

50 Coaxial cable 2.7/7.3AF Low Loss FRNC-C


Coaxials basing upon DIN 47264, EN 50117-1 and IEC 61196-1
Standards applied
DIN 47264; EN 50117-1; IEC 61196-1

Fire Rating Standards


Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-24 (cat. C)

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction
Inner conductor

Bare copper wire, 2.71 + 0.02 mm

Insulation

Foam skinned polyethylene (Foam-PE), 7.25 + 0.10 mm

Outer conductor

Aluminium PET Aluminium foil


and copper braid, tinned (ca. 93% optical coverage)

Sheath

FRNC, black RAL 9005, 10.3 + 0.2 mm

Technical Data
Prod.number
Draka Comteq

Designation

CK7550700 Low Loss FRNC-C

Type

Outer
diameter

Weight of
cable approx.

Copper
content

Tensile force

(inner/outer)

(mm)

(kg/km)

(kg/km)

(N)

2.7/7.3 AF

10.3

145.0

90.0

505

139

Mechanical Properties
Minimal bending radius
Temperature range,

during operation
during installation

50 mm without load (5 x outer diameter)


100 mm with load (10 x outer diameter)
-30C upto + 70C
-15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance
Inner conductor
.
Outer conductor
Mutual capacitance
Characteristic impedance
Nominal velocity of propagation
Transfer Impedance 1 MHz
.
10 MHz
.
100 MHz
Operating voltage
Test voltage
Inner/outer conductor
Screening factor
100-1000 MHz
1000-3000 MHz
Insulation resistance

3.1 /km
4.7 /km
nom. 79 pF/km
(50 2)
approx. 84 %
< 5 m/m
< 4 m/m
< 2 m/m
1.200 Vrms
5.000 Vrms
> 90 dB
> 80 dB
> 10 G.km

Electrical data (at 20 C)


f

Attenuation

(MHz)

(dB/100m)

Max. power rating

Return Loss

(W)

(dB)

(ambient temperature 40
C and max. inner
conductor temperature
100 C

(several peaks are allowed)

nominal

maximal

Frequency

(dB)

0.4

17.328

10-450 MHz

> 26

10

1.3

5.480

450-1000 MHz

> 23

100

4.1

1.710

1 3 GHz

> 18

200

5.7

1.132

500

9.3

716

800

12.2

585

1000

13.6

523

1500

16.7

427

2000

19.5

351

2500

22.1

325

3000

24.8

261

3500

27.1

240

4000

29.3

246

5250

34.3

216

5725

36.3

205

6000

37.2

200

www.DrakaMOG.com
140

50 Coaxial cable - RG 213 FRNC-B


RG-Cables acc. To MIL-C-17F and MIL-C-17G
Standards applied
acc. to MIL-C-17F and MIL-C-17G

Fire Rating Standards


Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-23 (cat. B)

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction
Inner conductor

Stranded copper wires 7 x 0.75, 2.25 + 0.01 mm

Insulation

Polyethylene (PE), 7.25 + 0.05 mm

Braid

Bare copper braid (ca. 96% optical coverage)

Sheath

FRNC, black 10.3 + 0.15 mm

Technical Data
Prod.number
Draka Comteq

Designation

CK2775400 M17/074 RG 214

Type

Outer
diameter

Weight of
cable approx.

Copper
content

Tensile force

(inner/outer)

(mm)

(kg/km)

(kg/km)

(N)

2.25L/7.25

10.3

157

86.7

470

141

Mechanical Properties
Minimal bending radius
Temperature range,

during operation
during installation

50 mm without load (5 x outer diameter)


100 mm with load (10 x outer diameter)
-40C upto + 85C
-15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance

Inner conductor
Outer conductor
Mutual capacitance
Characteristic impedance
Nominal velocity of propagation
Propagation delay
Delay skew
Operating voltage
Test voltage
Inner/outer conductor

5.7 /km
3.9 /km
nom. 100 pF/km
(50 2)
approx. 66 %
427 ns/100m
12 ns/100m
3.700 Vrms
10.000 Vrms

Electrical data (at 20 C)


f

Attenuation

Max. power rating

Return Loss

(MHz)

(dB/100m)

(W)

(dB)

(ambient temperature 25
C and max. inner
conductor temperature 70
C

(several peaks are


allowed)

28.0

10

1.8

2.300

100

6.8

920

200

9.0

570

400

14.4

380

1.000

24.7

210

1.500

31.5

170

2.000

36.4

140

3.000

46.6

100

5.200

62.0

73

5.800

67.0

67

23.5

www.DrakaMOG.com
142

Datacomm03_Jan_07

50 Coaxial cable - RG 214 FRNC-B


RG-Cables acc. To MIL-C-17F and MIL-C-17G
Standards applied
Acc. To MIL-C-17F and MIL-C-17G

Fire Rating Standards


Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-23 (cat. B)

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction
Inner conductor

Stranded copper wires, silver plated 7 x 0.75, 2.25 + 0.01 mm

Insulation

Polyethylene (PE), 7.25 + 0.05 mm

st

1 braid

Bare copper braid, silver plated (ca. 94% optical coverage)

2nd braid

Bare copper braid, silver plated (ca. 97% optical coverage)

Sheath

FRNC, black 10.8 + 0.15 mm

Technical Data
Prod.number
Draka Comteq

Designation

Type

Outer
diameter

Weight of
cable approx.

Copper
content

Tensile force

(inner/outer)

(mm)

(kg/km)

(kg/km)

(N)

10.8

200

132.9

730

CK2950901 M17/075 RG 214 FRNC-B 2.25Ls/7.25Ds

143

Mechanical Properties
Minimal bending radius
Temperature range,

during operation
during installation

50 mm without load (5 x outer diameter)


100 mm with load (10 x outer diameter)
-40C upto + 85C
-15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance
Inner conductor
.
1st braid
.
2nd braid
Mutual capacitance
Characteristic impedance
Nominal velocity of propagation
Maximum operating frequency
Operating voltage
Test voltage
Inner/outer conductor

5.7 /km
6.2 /km
6.2 /km
nom. 100 pF/km
(50 2)
approx. 66 %
11 GHz
3.700 Vrms
10.000 Vrms

Electrical data (at 20 C)


f

Attenuation

(MHz)

(dB/100m)

Max. power rating

Return Loss

(W)

(dB)

(ambient temperature 25
C and max. inner
conductor temperature 70
C

(several peaks are


allowed)

50

4.9

1.500

100

6.9

920

> 23

400

15.1

330

1.000

26.5

160

> 20

3.000

50.6

75

> 19

5.000

> 18

5.200

67.8

61

5.800

73.0

56

11.000

> 17

www.DrakaMOG.com
144

Datacomm04_Jan_07

50 Coaxial cable - RG 214 PVC


RG-Cables acc. To MIL-C-17F and MIL-C-17G
Standards applied
Acc. To MIL-C-17F and MIL-C-17G

Fire Rating Standards


Flame propogation

IEC 60332-1

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction
Inner conductor

Stranded copper wires, silver plated 7 x 0.75, 2.25 + 0.01 mm

Insulation

Polyethylene (PE), 7.25 + 0.05 mm

1st braid

Bare copper braid, silver plated (ca. 94% optical coverage)

2nd braid

Bare copper braid, silver plated (ca. 97% optical coverage)

Sheath

PVC, black 10.8 + 0.15 mm

Technical Data
Prod.number
Draka Comteq

Designation

CK2775700 M17/075 RG 214

Type

Outer
diameter

Weight of
cable approx.

Copper
content

Tensile force

(inner/outer)

(mm)

(kg/km)

(kg/km)

(N)

2.25Ls/7.25Ds

10.8

200

132.9

730

145

Mechanical Properties
Minimal bending radius
Temperature range,

during operation
during installation

50 mm without load (5 x outer diameter)


100 mm with load (10 x outer diameter)
-40C upto + 85C
-15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance
Inner conductor
.
1st braid
.
2nd braid
Mutual capacitance
Characteristic impedance
Nominal velocity of propagation
Maximum operating frequency
Operating voltage
Test voltage
Inner/outer conductor

5.7 /km
6.2 /km
6.2 /km
nom. 100 pF/km
(50 2)
approx. 66 %
11 GHz
3.700 Vrms
10.000 Vrms

Electrical data (at 20 C)


f

Attenuation

(MHz)

(dB/100m)

Max. power rating

Return Loss

(W)

(dB)

(ambient temperature 25
C and max. inner
conductor temperature 70
C

(several peaks are


allowed)

50

4.9

1.500

100

6.9

920

> 23

400

15.1

330

1.000

26.5

160

> 20

3.000

50.6

75

> 19

5.000

> 18

5.200

67.8

61

5.800

73.0

56

11.000

> 17

www.DrakaMOG.com
146

Datacomm05_Jan_07

50 Coaxial cable - RG 223 FRNC-B


RG-Cables acc. To MIL-C-17F and MIL-C-17G
Standards applied
Acc. To MIL-C-17F and MIL-C-17G

Fire Rating Standards


Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-24 (cat. C)

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction
Inner conductor

Stranded copper wires, silver plated 0.9 + 0.01 mm

Insulation

Polyethylene (PE), 2.95 + 0.05 mm

st

1 braid

Bare copper braid, silver plated (ca. 96% optical coverage)

2nd braid

Bare copper braid, silver plated (ca. 96% optical coverage)

Sheath

FRNC, black 5.4 + 0.10 mm

Technical Data
Prod.number
Draka Comteq

Designation

Type

Outer
diameter

Weight of
cable approx.

Copper
content

Tensile force

(inner/outer)

(mm)

(kg/km)

(kg/km)

(N)

5.4

54.7

40.5

240

CK7676500 M17/84 RG 223 FRNC-B 0.89s/2.95Ds

147

Mechanical Properties
Minimal bending radius
Temperature range,

during operation
during installation

25 mm without load (5 x outer diameter)


50 mm with load (10 x outer diameter)
-40C upto + 85C
-15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance
Inner conductor
.
1st braid
.
2nd braid
Mutual capacitance
Characteristic impedance
Nominal velocity of propagation
Maximum operating frequency
Operating voltage
Test voltage
Inner/outer conductor

29.1 /km
13.5 /km
13.5 /km
nom. 100 pF/km
(50 2)
approx. 66 %
12.4 GHz
1.400 Vrms
5.000 Vrms

Electrical data (at 20 C)


f

Attenuation

(MHz)

(dB/100m)

Max. power rating

Return Loss

(W)

(dB)

(ambient temperature 25
C and max. inner
conductor temperature 70
C

(several peaks are


allowed)
Frequency

(dB)

50

9.8

350

100 MHz

> 27.0

400

28.4

86

1 GHz

> 23.5

1.000

45.9

50

2 GHz

> 21.5

3.000

83.1

32

4-5 GHz

> 21.0

5.200

112.7

24

10 GHz

> 20.0

5.800

120.6

22

www.DrakaMOG.com
148

Datacomm06_Jan_07

50 Coaxial cable - RG 223 PVC


RG-Cables acc. To MIL-C-17F and MIL-C-17G
Standards applied
Acc. To MIL-C-17F and MIL-C-17G

Fire Rating Standards


Flame propogation

IEC 60332-1

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction
Inner conductor

Stranded copper wires, silver plated 0.9 + 0.01 mm

Insulation

Polyethylene (PE), 2.95 + 0.05 mm

1st braid

Bare copper braid, silver plated (ca. 96% optical coverage)

2nd braid

Bare copper braid, silver plated (ca. 96% optical coverage)

Sheath

PVC, black 5.4 + 0.10 mm

Technical Data
Prod.number
Draka Comteq

Designation

CK2776500 M17/84 RG 223

Type

Outer
diameter

Weight of
cable approx.

Copper
content

Tensile force

(inner/outer)

(mm)

(kg/km)

(kg/km)

(N)

0.89s/2.95Ds

5.4

54.7

40.5

240

149

Mechanical Properties
Minimal bending radius
Temperature range,

during operation
during installation

25 mm without load (5 x outer diameter)


50 mm with load (10 x outer diameter)
-40C upto + 85C
-15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance
Inner conductor
.
1st braid
.
2nd braid
Mutual capacitance
Characteristic impedance
Nominal velocity of propagation
Maximum operating frequency
Operating voltage
Test voltage
Inner/outer conductor

29.1 /km
13.5 /km
13.5 /km
nom. 100 pF/km
(50 2)
approx. 66 %
12.4 GHz
1.400 Vrms
5.000 Vrms

Electrical data (at 20 C)


f

Attenuation

(MHz)

(dB/100m)

Max. power rating

Return Loss

(W)

(dB)

(ambient temperature 25
C and max. inner
conductor temperature 70
C

(several peaks are


allowed)
Frequency

(dB)

50

9.8

350

100 MHz

> 27.0

400

28.4

86

1 GHz

> 23.5

1.000

45.9

50

2 GHz

> 21.5

3.000

83.1

32

4-5 GHz

> 21.0

5.200

112.7

24

10 GHz

> 20.0

5.800

120.6

22

www.DrakaMOG.com
150

Datacomm07_Jan_07

6 FOILS 4x2x0.57 (AWG 23) MULTIMEDIA LSHF-FR


Shielded 100 Data cable ISO/IEC 11801 CAT-7
Standards applied
International
USA
Europe

ISO/IEC 11801 2nd ed.


ANSI/EIA/TIA 568A
NEN-EN 50173

Cat 7
Construction

NEN 11156-5 (IEC 61156)


NEN-EN 50288-2-1

Application

Fire Rating Standards

Primary (Campus), Secondary (Riser), Tertiary


(Horizontal) IEEE 802.3: 10Base-T; 100Base-T;
1000Base-T; 10Gbase-T; IEEE 802.5 16MB; ISDN;
TPDDI; ATM

Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-24 (cat. C)

Construction
Conductor

Bare copper wire 0.57 mm (AWG23)

Insulation

Polyethylene, 1.4 mm

Pair screen

Al-laminated plastic foil,


Patented wrapping of two pairs each

Twisting

2 cores to the pair

Cable lay up

4 pair to the core

Overall sheath

Copper braid, tinned (ca. 65% coverage)

Sheath

LSHF, mellon orange RAL 1028

Sheath marking

DRAKA COMTEQ 6FOIL S/FTP 4x2x0.57 MULTIMEDIA

Core identification
(in accordance ISO/IEC 11801 2nd edition)
Pair 1
white/blue and blue,
Pair 2
white/orange and orange,
Pair 3
white/green and green,
Pair 4
white/brown and brown

Technical Data
Prod.number
Draka Comteq

Designation

CD7679731 S/FTP AWG23 LSHF-FR

No. of cores
and
cond.area

Outer
diameter

Fire Load

(mm2)

(mm)

(MJ/km) (kWh/m)

2x2x0.57

7.9

151

642

0.178

Weight of
cable
approx.

Copper
content

Tensile
force

(kg/km)

(kg/km)

(N)

81

39

340

Mechanical Properties
Bending radius
Temperature range,

during operation
during installation

35 mm without load
70 mm with load
-20C upto + 60C
0C upto + 50C

Electrical Properties (at 20C 5C)


DC loop resistance
Resistance unbalance
Insulation resistance (500 V)
Capacitance at 800 Hz
Capacitance unbalance (pair to ground)
Characteristic impedance (1-100 MHz)
(100-250 MHz)
(250-600 MHz)
(600-1200 MHz)
Nominal velocity of propagation
Propagation delay
Delay skew
Test voltage (DC, 1 min)
Core/Core and Core/Screen
Transfer impedance
at 1 MHz
at 10 MHz
at 30 MHz
at 100 MHz

135 /km
2%
2000 M *km
nom. 43 nF/km
1500 pF/km
(100 15)
(100 18)
(100 25)
(100 30)
approx. 79 %
427 ns/100m
12 ns/100m
1000 V
5 m /m
5 m /m
15 m /m
30 m /m

Nominal transmission characteristics acc. to Category 7 (at 20 C)


f

Attenuation

NEXT

PS-NEXT

ACR

PS-ACR

ELFEXT

PS-ELFEXT

Return loss

(MHz)

(dB/100m)

(dB)

(dB)

(dB/100m)

(dB/100m)

(dB/100m)

(dB/100m)

(dB)

1.0

2.0

117

114

115

112

105

103

20

4.0

3.6

117

114

113

110

93

91

23

10.0

5.7

117

114

112

109

85

83

25

16.0

7.2

114

111

107

104

81

79

25

20.0

8.1

113

110

105

102

79

77

25

31.2

10.1

110

107

100

97

75

73

24

62.5

14.5

105

102

91

88

69

67

22

100.0

18.5

102

99

84

81

65

63

20

125.0

21.1

101

98

80

77

63

61

19

155.5

23.4

100

97

76

73

61

59

19

175.0

25.1

99

96

74

71

60

58

18

200.0

26.8

98

95

71

68

59

57

18

250.0

30.1

96

93

66

63

57

55

17

300.0

33.0

95

92

62

59

55

53

17

450.0

42.6

93

90

50

47

52

50

17

600.0

49.0

91

88

42

39

49

47

17

750.0

63.3

87

84

24

21

45

43

900.0

69.3

86

83

17

14

43

41

1000.0

77.5

85

82

7.3

4.3

41

39

152
www.DrakaMOG.com

75 CATV cable 1.0/4.8 AF FRNC-C


CATV Drop Cable
Standards applied
Screening efficiency EN 50117-1

Application

Fire Rating Standards

Drop cables are used in TV signal distribution


networks and as antenna cable for terrestric and
satellite broadcast systems.

Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-24 (cat. C)

Construction
Inner conductor

Bare copper wire, 1.0 mm

Insulation

Foam skinned polyethylene (Foam-PE), 4.65 + 0.10 mm

Outer conductor

Aluminium PET Aluminium foil


under copper braid, tinned (ca. 40% optical coverage)

Sheath

FRNC-C, white 6.8 + 0.2 mm

Technical Data
Prod.number
Draka Comteq

Designation

CT2850402 1.0/4.8AF FRNC-C

Type

Outer
diameter

Weight of
cable approx.

Copper
content

Tensile force

(inner/outer)

(mm)

(kg/km)

(kg/km)

(N)

1.0/4.8 AF

6.8

45.0

14.5

110

153

Electrical Properties (at 20C 5C)


DC resistance
Inner conductor
.
Outer conductor
Mutual capacitance
Characteristic impedance
Nominal velocity of propagation
Screening factor
30-1000 MHz

22 /km
25 /km
nom. 55 pF/km
(75 2)
approx. 85 %
> 80 dB

Electrical data (at 20 C)


f

Attenuation

Return Loss

(MHz)

(dB/100m)

(dB)
(several peaks are allowed)

nominal

Frequency

(dB)

1.6

5 30 MHz

> 26

50

4.6

30 470 MHz

> 23

100

6.4

480 862 MHz

> 20

200

8.9

862 2150 MHz

> 18

400

12.7

862

18.9

950

19.8

1000

20.5

1350

23.8

1600

26.4

1750

27.6

2150

30.8

2550

33.6

3000

36.5

www.DrakaMOG.com
154

Datacomm08_Jan_07

75 CATV cable 1.6/7.3 AF FRNC


CATV Distribution and Drop Cable
Standards applied
Screening efficiency acc. to EN 50117-1 and
draft EN 50117-2-2, 4 a 5
May 2002.
EN 50083-2/A1 screening
class A

Application

Fire Rating Standards

Drop cables are used in TV signal distribution


networks and as antenna cable for terrestric and
satellite broadcast systems.

Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-24 (cat. C)

Construction
Inner conductor

Bare copper wire, 1.6 mm

Insulation

Foam skinned polyethylene (Foam-PE), 7.2 mm

Outer conductor

Aluminium PET Aluminium foil


under copper braid, tinned (ca. 60% optical coverage)

Sheath

FRNC-C, black 10.0 + 0.3 mm

Technical Data
Prod.number
Draka Comteq

Designation

Type

Outer
diameter

Weight of
cable approx.

Copper
content

Bending
radius

Tensile force

(inner/outer)

(mm)

(kg/km)

(kg/km)

(mm)

(N)

10.0

85.0

35.3

50.0

300

CT2760901 1.6/7.3AF FRNC-C 1.6/7.3 AF

155

Electrical Properties (at 20C 5C)


DC resistance
Inner conductor
.
Outer conductor
Mutual capacitance
Characteristic impedance
Nominal velocity of propagation
Screening factor
30-1000 MHz

9 /km
14 /km
nom. 55 pF/km
(75 2)
approx. 80 %
> 80 dB

Electrical data (at 20 C)


f

Attenuation

Return Loss

(MHz)

(dB/100m)

(dB)
(several peaks are allowed)

nominal

Frequency

(dB)

1.0

5 30 MHz

> 26

50

3.0

30 470 MHz

> 23

100

4.2

480 862 MHz

> 20

200

6.0

862 2150 MHz

> 18

400

8.8

862

12.9

1000

14.6

1350

17.5

1600

19.3

1750

20.2

2150

23.1

2550

25.2

3000

27.8

www.DrakaMOG.com
156

Datacomm09_Jan_07

75 CATV cable Coax10 AD 10S FRNC-C


CATV Drop Cable
Standards applied
Screening
efficiency

Screening Class A
acc. to EN 50117-2-1, EN
50117-2-2, EN 50117-2-4 and
EN 50117-2-5 further EN
500083-2A1, EN 50117-1.

Application

Fire Rating Standards

Drop cables are used in private and commercial TV


signal distribution networks and as antenna cable
for terrestrial and satellite broadcast systems. This
predestined head-end cable is manufactured with
vacuum technology. The cable layers thereby have
high friction forces which allow automatic
dismantling also at small lengths.

Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-24 (cat. C)

Construction
Inner conductor

Bare copper wire, 1.0 mm

Insulation

Gas injected foam polyethylene (Foam-PE), 4.55 mm

Outer conductor

Aluminium PET foil, longitudinal, bonded to the insulation,


under copper braid, tinned (ca. 70% optical coverage) and Aluminium PET
foil longitudinal, bonded to the sheath, 4.55 mm

Sheath

FRNC-C, black 6.8 + 0.2 mm

Marking

DRAKA COMTEQ OAX10 AD S + meter marking + batch number

Technical Data
Prod.number
Draka Comteq

Designation

CK2689305 Coax10 AD 10 S FRNC-C

Outer
diameter

Weight of
cable approx.

Copper
content

Bending
radius

Tensile force

(mm)

(kg/km)

(kg/km)

(mm)

(N)

6.8

47.0

21.9

35.0

175

157

Mechanical Properties
Minimal bending radius Without load
.
With load
Temperature range
during operation
.
during installation
Corrosiveness
FRNC-C
Friction forces between cable layers
Dielectric foil braid foil - sheath.
Inner conductor dielectric
(acc. to DIN EN 50 289-3-17)

30 mm (5 x outer diameter)
65 mm (10 x outer diameter)
-40C upto + 85C
-15C upto + 55C
acc. to IEC 60754-2
> 80 N
(Pull test with 300 mm overlapping zone)
> 15 N
(Pull test with 50 mm overlapping zone)

Electrical Properties (at 20C 5C)


DC resistance
Inner conductor
.
Outer conductor
Mutual capacitance
Characteristic impedance
Nominal velocity of propagation
Screening factor
30-1000 MHz
1 - 2 GHz
2 - 3 GHz
Transfer impedance 5 - 30 MHz
Electrical strength
Dilectric
Sheath

22 /km
14 /km
nom. 52 pF/km
(75 2)
approx. 85 %
> 110 dB
> 100 dB
> 100 dB
> 5 m.m
2 kVDC 1 min
3.75 kVDC 1 min

Electrical data (at 20 C)


f

Attenuation

Return Loss

(MHz)

(dB/100m)

(dB)
(several peaks are allowed)

nominal

Frequency

(dB)

1.6

5 30 MHz

> 26

50

4.3

30 470 MHz

> 24

100

6.2

470 1000 MHz

> 20

200

8.7

1000 3000 MHz

> 18

400

12.5

862

18.6

950

19.8

1350

23.7

1750

27.2

2150

30.5

3000

36.9

www.DrakaMOG.com
158

Datacomm10_Jan_07

Analogue Audio Cable 110 AC10 SS 26/7 10P


Analogue Audio Cable based upon ARD-specification and acc. to AES/EBUrecommendation
Fire Rating Standards
Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-24 (cat. C)

Application
Audio cables are used in professional broadcasting systems for the transmission of analogue and
digital signals.

Construction
Inner conductor

Stranded bare copper wires, 0.48 mm (0.14 mm / AWG 26/7)

Insulation

Foam skinned polyethylene (Foam-PE), 1.2 mm

Pair stranding

Two cores twisted to the pair

Pair identification

a core: white, b core: blue


(the above colours in regular intervals)

Pair screen

Aluminium PET foil, aluminium inside and stranded copper drain wires,
tinned.

Pair insulation of
the one-pair cable

PET foil.

Pair insulation of
FRNC, flame retardant copolymer
the multi-pair cable
Colour and
identification

Grey RAL 7001 with number printing

Cable lay-up

n-pairs twisted in layers

Overall screen

Aluminium-PET foil under copper braid, tinned.

Sheath

FRNC-C, grey RAL 7001 13.7 mm

Marking

DRAKA MULTIMEDIA CABLE GERMANY AC 10 SS 26/7 10P AES/EBU

Technical Data
Prod.number
Draka Comteq

Designation

Type

Outer
diameter

Weight of
cable approx.

Copper
content

Tensile force

(nxnxmm)

(mm)

(kg/km)

(kg/km)

(N)

13.7

195.0

110.9

550

CT7651811 AC10 SS 26/7 10P PiMF 10x2x20.48


159

Mechanical Properties
Minimal bending radius
.
Temperature range
Corrosiveness

Without load
With load
FRNC-C

130 mm (10 x outer diameter)


200 mm (15 x outer diameter)
-30C upto + 70C
acc. to IEC 60754-2

Electrical Properties (at 20C 5C)


DC loop resistance
Insulation resistance
Mutual capacitance at 800 Hz
Capacitance unbalance (pair to ground)
Nominal velocity of propagation
Test voltage (50 Hz, 1min)
Core/core and core/screen)
Characteristic impedance (6 MHz)
Transfer impedance up to 10 MHz
up to 100 MHz

< 288 /km


2000 M.km
Nom. 45 nF/km
< 1200 pF/km
approx. 78 %
700 VRMS
110 10%
> 10 m.m
> 100 m.m

Electrical data (at 20 C)


f

NEXT

Attenuation

(MHz)

(dB/300m)

(dB/100m)

0.015

85

0.55

1.0

85

3.0

4.0

90

5.3

10.0

90

8.1

20.0

85

11.5

www.DrakaMOG.com
160

Datacomm11_Jan_07

D92aici.e20
12.09.2007 14:51
Page 1 of 2

Flame retardant AICI-I/O/RM-W


Armoured industrial cable

AICI-I/O/RM-W
Indoor and outdoor
Flame retardant and halogen free
Steel wire braiding
Tight buffer
Optical cable for industrial environments. The cable is suitable
for both indoor and outdoor installation. Continiuous
submergence in water is not recommended. Outer sheath is
made from black UV-stabilized and weather resistant material
and may be exposed for shorter periods to fluids such as
diesel and mineral oils. The resistance to these fluids is
according to IEC60811-2-1. The cable is reinforced with a
steel wire braiding between the two sheaths. Strength
elements of glass yarn around the cable core allow easy
installation of long lengths. The 0.9 mm tight buffer is easy to
strip allowing fast and reliable splicing and connector
mounting. Each fibre is colour coded for easy identification.
The outer sheath is marked to show fibre type and cable type.

Secondary coated fibre


Water swellable material
Glass yarn
Inner sheath
Steel wire braiding
Outer sheath

Weight and dimensions


Number of fibres

Secondary coating

Outer diameter

Weight

[mm]
0.9
0.9
0.9
0.9

[mm]

[kg/km]

4
8
12
24

8.2
9.4
10.3
12.0

90
125
145
185

Tensile strength*
[Inst./oper.]
[N]
700/250
800/350
1200/500
1700/750

Cable properties
*Tensile strength (IEC 60794-1-2E1)
Max tensile load during installation
Max tensile load during operation

Temperature window

See above
See above

Operation

-40C to +70C

Installation

-10C to +70C

Storage
Crush (IEC 60794-1-2E3)
Impact (IEC 60794-1-2E4)
Torsion (IEC 60794-1-2E7)

2000 N/10cm Water tightness* (IEC 60794-1-2F5B)

-40C to +70C

< 3 m/24 hours

1 impacts, 25J Fire and smoke classifications


1 turn/1m IEC 60332-1
IEC 60332-3-22 (Cat. A)
IEC 60332-3-24 (Cat. C)

Cable bending
Minimum bending diameter
Cable bend (IEC 60794-1-2E11)
Flexibility (IEC 60794-1-2E8)

15x outer diameter IEC 61034


<0.5 dB/ 5 turn IEC 60754-1
1000 cycles IEC 60754-2
Chemical reistance
Mineral oils IRM 902 (IEC60811-2-1)

- 7 days/23C
- 4 hours/70C

Diesel - IRM 903 (IEC60811-2-1)

- 7 days/23C
- 4 hours/70C

*) Steel wire braiding is not watertight.

www.drakaMOG.com
161

D92aici.e20
12.09.2007 14:51
Page 2 of 2

Flame retardant AICI-I/O/RM-W


Ordering information
9/125 fibre(SMF652D), Black**

50/125 fibre(MMF50HiCap), Black**

Part no.
Cable code
Part no.
695420 G4-9/125 AICI-I/O/RM-W
695422
695440 G8-9/125 AICI-I/O/RM-W
695442
695450 G12-9/125 AICI-I/O/RM-W
695452
695480 G24-9/125 AICI-I/O/RM-W
695482
**)-Standard colour of outer sheath
We reserve the right to alter this specification without notice.

Cable code
G4-50/125 AICI-I/O/RM-W
G8-50/125 AICI-I/O/RM-W
G12-50/125 AICI-I/O/RM-W
G24-50/125 AICI-I/O/RM-W

62.5/125 fibre(MMF62HiCap), Black**


Part no.
695424
695444
695454
695484

Cable code
G4-62.5/125 AICI-I/O/RM-W
G8-62.5/125 AICI-I/O/RM-W
G12-62.5/125 AICI-I/O/RM-W
G24-62.5/125 AICI-I/O/RM-W

Optical fibres
Fibre type
Reference(DNK)
IEC60793-2-50 category
IEC11801 classification
ITU-T type
Gigabit Ethernet maximum
distances
SX-serial(850 nm)
LX-serial(1310 nm)
10Gigabit Ethernet maximum
distances
SX-serial(850 nm)
LX-serial(1310 nm)
Core diameter
Mode field diameter
Cladding diam. loose tube
Cladding diam. tight buffer
Primary coating diameter
(nominal)
Attenuation
(Typical values)
850 nm
1300 nm
1310 nm
1550 nm
Attenuation
(Maximum values)
850 nm
1300 nm
1310 nm
1550 nm
Bandwidth(OFL*)
850 nm
1300 nm
Chromatic Dispersion
1285-1330 nm
1550 nm
Polarization Mode Disp.
PMD Link Design Value **
Max. Individual Fibre
Numerical aperture
Minimum permanent bending
diameter

HiCap
50/125
MMF50HiCap

9/125
SMF652D
B.1.3
OS1 and OS2
G652.D

MaxCap
HiCap 62.5/125
50/125
MMF50MaxCap
MMF62HiCap
A1a
A1a.2
A1b
OM2
OM3
OM1
G651
G651
-

750 m
2000 m

900 m
550 m

500 m
1000 m

110 m

300 m

65 m

50 2.5 m

50 2.5 m

62.5 2.5 m

125 2.0 m
125 2.0 m
250 m

125 2.0 m
125 2.0 m
250 m

125 2.0 m
125 2.0 m
250 m

2.5 dB/km
0.7 dB/km

2.5 dB/km
0.7 dB/km

3.0 dB/km
0.7 dB/km

2.7 dB/km
0.8 dB/km

2.7 dB/km
0.9 dB/km

3.2 dB/km
1.0 dB/km

>600 MHzkm
>1200 MHzkm

>1500 MHzkm
>500 MHzkm

>200 MHzkm
>600 MHzkm

0.06 km
0.1 km
0.13 ( nominal)

0.200 0.015

0.200 0.015

0.275 0.015

50 mm

50 mm

50 mm

50 mm

5000m

10000 m
See mode field diameter
1310 nm 9.2 0.4 m
1550 nm 10.3 0.5 m
125 0.7 m
125 0.7 m
242 7 m

0.33 0.37 dB/km


0.19 0.23dB/km

0.40 dB/km
0.25 dB/km

3 ps/nmkm
18 ps/nmkm

* Over Filled Launch methode(OFL). Modal Bandwidth in accordance with IEC60793-1-41.


** According to IEC 60794-3, Ed.3 (Q=0.01%)
Other fibre types and qualities are available on request.

www.drakaMOG.com
162

Rev: 09/07

Cat. 5e SF/UTP 4x2x0.51 (AWG 24) FRNC-C


Shielded 100 Data cable ISO/IEC 11801 CAT-5e
Standards applied
International
USA
Europe

ISO/IEC 11801 2nd ed.


ANSI/EIA/TIA 568A
NEN-EN 50173

Cat 5e
Construction

NEN 11156-5 (IEC 61156)


NEN-EN 50288-2-1

Application

Fire Rating Standards

Primary (Campus), Secondary (Riser), Tertiary


(Horizontal) IEEE 802.3: 10Base-T; 100Base-T;
1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI;
ATM

Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-24 (cat. C)

Construction
Conductor

Bare copper wire 0.51 mm (AWG24)

Insulation

Polyethylene, 1.1 mm

Twisting

2 cores to the pair

Cable la yup

4 pair to the core

Overall sheath

Al-laminated plastic foil and Copper braid, tinned (coverage > 40%)

Sheath

LSHF, grey RAL 7035

Sheath marking

DRAKA COMTEQ MULTIMEDIA SF/UTP CAT-5e 4x2x0.51

Core identification
(in accordance ISO/IEC 11801 2nd edition)
Pair 1
white/blue and blue,
Pair 2
white/orange and orange,
Pair 3
white/green and green,
Pair 4
white/brown and brown

Technical Data
Prod.number
Draka Comteq

Designation

CD7677530 SF/UTP Cat.5 FRNC-C

No. of cores
and
cond.area

Outer
diameter

Fire Load

(mm2)

(mm)

(MJ/km) (kWh/m)

2x2x0.51

6.4

163

433

0.120

Weight of
cable
approx.

Copper
content

Tensile
force

(kg/km)

(kg/km)

(N)

47

27

120

Mechanical Properties
Bending radius
Temperature range,

during operation
during installation

25 mm without load
50 mm with load
-20C upto + 60C
0C upto + 50C

Electrical Properties (at 20C 5C)


190 /km
2%
2000 M *km
nom. 48 nF/km
1500 pF/km
(100 15)
approx. 67 %
535 ns/100m
20 ns/100m
1000 V

DC loop resistance
Resistance unbalance
Insulation resistance (500 V)
Capacitance at 800 Hz
Capacitance unbalance (pair to ground)
Characteristic impedance (1-100 MHz)
Nominal velocity of propagation
Propagation delay
Delay skew
Test voltage (DC, 1 min)
Core/Core and Core/Screen
Transfer impedance
at 1 MHz
at 10 MHz
at 30 MHz
at 100 MHz

20 m /m
20 m /m
30 m /m
60 m /m

Nominal transmission characteristics acc. to Category 5e (at 20 C)


f

Attenuation

NEXT

PS-NEXT

ACR

PS-ACR

ELFEXT

PS-ELFEXT Return loss

(MHz)

(dB/100m)

(dB)

(dB)

(dB/100m)

(dB/100m)

(dB/100m)

(dB/100m)

(dB)

1.0

1.9

71

68

69.1

66.1

68

65

20

4.0

3.7

62

59

58.3

55.3

56

53

23

10.0

6.0

56

53

50.0

47.0

48

45

25

16.0

7.6

53

50

45.4

42.4

44

41

25

20.0

8.5

51

48

42.5

39.5

42

39

25

31.2

10.7

49

46

38.3

35.3

38

35

24

62.5

15.7

44

41

28.3

25.3

32

29

22

100.0

19.8

41

38

21.2

18.2

28

25

20

125.0

22.3

40

37

17.7

14.7

26

23

19

155.5

24.2

38

35

13.8

10.8

24

21

175.0

25.7

37

34

11.3

8.3

23

20

200.0

27.5

36

33

8.5

5.5

22

19

250.0

29.2

35

32

5.8

2.8

20

17

300.0

32.0

34

31

2.0

-1.0

16

13

www.DrakaMOG.com
164

Datacomm12_Jan_07

Cat. 7 S/FTP 4x2x0.42 (AWG 27/7) Patch LSHF


Shielded 100 Data Patchcable ISO/IEC 11801 CAT-7
Standards applied
International
USA
Europe

ISO/IEC 11801 2nd ed.


ANSI/EIA/TIA 568A
NEN-EN 50173

Cat 7
Construction

NEN 11156-5 (IEC 61156)


NEN-EN 50288-2-1

Application

Fire Rating Standards

Tertiary (Horizontal)
IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T;
10Gbase-T; IEEE 802.5 16MB; ISDN; TPDDI;
ATM

Halogen Free
Low smoke
Flame propogation

IEC 60754-2
IEC 61034-1,2
IEC 60332-1

Construction
Conductor

Bare copper wire 0.42 mm (AWG27/7)

Insulation

Foam-skin Polyethylene, 0.98 mm

Pair screen

Al-laminated plastic foil

Twisting

2 cores to the pair

Cable lay up

4 pair to the core

Overall sheath

Copper braid, tinned (ca. 45% coverage)

Sheath

LSHF, orange

Core identification
(in accordance ISO/IEC 11801 2nd edition)
Pair 1
white/blue and blue,
Pair 2
white/orange and orange,
Pair 3
white/green and green,
Pair 4
white/brown and brown

Technical Data
Prod.number
Draka Comteq

Designation

No. of cores
and
cond.area

Outer
diameter

Fire Load

(mm2)

(mm)

(MJ/km) (kWh/m)

CD7677650 S/FTP Cat.7 AWG27/7 PiMF 2x2x0.42

165

5.9

349

0.097

Weight of
cable
approx.

Copper
content

Tensile
force

(kg/km)

(kg/km)

(N)

39

24

100

Mechanical Properties
Bending radius
Temperature range,

during operation
during installation

25 mm without load
50 mm with load
-20C upto + 60C
0C upto + 50C

Electrical Properties (at 20C 5C)


DC loop resistance
Resistance unbalance
Insulation resistance (500 V)
Capacitance at 800 Hz
Capacitance unbalance (pair to ground)
Characteristic impedance (1-100 MHz)
(100-250 MHz)
(250-600 MHz)
Nominal velocity of propagation
Propagation delay
Delay skew
Test voltage (DC, 1 min)
Core/Core and Core/Screen
Transfer impedance
at 1 MHz
at 10 MHz
at 30 MHz

340 /km
3%
2000 M *km
nom. 43 nF/km
1500 pF/km
(100 15)
(100 18)
(100 25)
approx. 79 %
427 ns/100m
12 ns/100m
1000 V
25 m /m
15 m /m
30 m /m

Nominal transmission characteristics acc. to Category 7 (at 20 C)


f

Attenuation

NEXT

PS-NEXT

ACR

PS-ACR

ELFEXT

PS-ELFEXT

Return loss

(MHz)

(dB/100m)

(dB)

(dB)

(dB/100m)

(dB/100m)

(dB/100m)

(dB/100m)

(dB)

1.0

0.3

90

87

90

80

77

77

23

4.0

0.6

90

87

89

80

77

77

24

10.0

1.0

90

87

89

80

77

77

25

16.0

1.3

90

87

89

76

73

73

25

20.0

1.4

90

87

89

74

71

71

25

31.2

1.8

90

87

88

70

67

67

25

62.5

2.6

90

87

87

64

61

61

23

100.0

3.2

87

84

84

60

57

57

21

125.0

3.6

85

82

81

58

55

55

20

155.5

4.0

84

81

80

56

53

53

19

175.0

4.3

83

80

79

55

52

52

19

200.0

4.6

82

79

77

54

51

51

18

250.0

5.1

81

78

76

52

49

49

18

300.0

5.6

80

77

74

50

47

47

17

450.0

6.9

77

74

70

47

44

44

17

600.0

7.9

75

72

67

44

41

41

17

750.0

8.7

73

70

64

42

39

39

900.0

9.7

72

69

62

41

38

38

1000.0

10.2

71

68

61

40

37

37

166
www.DrakaMOG.com

Cat. 7 S/FTP 4x2x0.56 (AWG 23) LSHF


Shielded 100 Data cable ISO/IEC 11801 CAT-7
Standards applied

Application

International
USA
Europe

ISO/IEC 11801 2nd ed.


ANSI/EIA/TIA 568A
NEN-EN 50173

Cat 7
Construction

NEN 11156-5 (IEC 61156)


NEN-EN 50288-2-1

Fire Rating Standards

Primary (Campus), Secondary (Riser), Tertiary


Halogen Free
(Horizontal) IEEE 802.3: 10Base-T; 100Base-T;
Low smoke
1000Base-T; 10Gbase-T; IEEE 802.5 16MB; ISDN; Flame propogation
TPDDI; ATM

IEC 60754-2
IEC 61034-1,2
IEC 60332-1

Construction
Conductor

Bare copper wire 0.56 mm (AWG23)

Insulation

Polyethylene, 1.35 mm

Pair screen

Al-laminated plastic foil

Twisting

2 cores to the pair

Cable lay up

4 pair to the core

Overall sheath

Copper braid, tinned (ca. 40% coverage)

Sheath

LSHF, orange

Sheath marking

DRAKA COMTEQ S/FTP CAT-7 4x2x0.56

Core identification
(in accordance ISO/IEC 11801 2nd edition)
Pair 1
white/blue and blue,
Pair 2
white/orange and orange,
Pair 3
white/green and green,
Pair 4
white/brown and brown

Technical Data
Prod.number
Draka Comteq

Designation

No. of cores
and
cond.area

Outer
diameter

Fire Load

(mm2)

(mm)

(MJ/km) (kWh/m)

CD7679365 S/FTP Cat.7 AWG23 PiMF 2x2x0.56

7.0

167

590

0.170

Weight of
cable
approx.

Copper
content

Tensile
force

(kg/km)

(kg/km)

(N)

65

26

110

Mechanical Properties
Bending radius
Temperature range,

during operation
during installation

40 mm without load
80 mm with load
-20C upto + 60C
0C upto + 50C

Electrical Properties (at 20C 5C)


DC loop resistance
Resistance unbalance
Insulation resistance (500 V)
Capacitance at 800 Hz
Capacitance unbalance (pair to ground)
Characteristic impedance (1-100 MHz)
(100-250 MHz)
(250-600 MHz)
Nominal velocity of propagation
Propagation delay
Delay skew
Test voltage (DC, 1 min)
Core/Core and Core/Screen
Transfer impedance
at 1 MHz
at 10 MHz
at 30 MHz
at 100 MHz

165 /km
2%
2000 M *km
nom. 43 nF/km
1500 pF/km
(100 15)
(100 18)
(100 25)
approx. 79 %
427 ns/100m
12 ns/100m
1000 V
20 m /m
30 m /m
40 m /m
200 m /m

Nominal transmission characteristics acc. to Category 7 (at 20 C)


f

Attenuation

NEXT

PS-NEXT

ACR

PS-ACR

ELFEXT

PS-ELFEXT

Return loss

(MHz)

(dB/100m)

(dB)

(dB)

(dB/100m)

(dB/100m)

(dB/100m)

(dB/100m)

(dB)

1.0

1.8

100

97

98

95

105

105

4.0

3.4

100

97

97

94

105

102

27

10.0

5.4

100

97

95

92

97

94

30

16.0

6.8

100

97

93

90

93

90

30

20.0

7.7

100

97

92

89

91

88

30

31.2

9.6

100

97

90

87

87

84

30

62.5

13.7

100

97

86

83

81

78

30

100.0

17.4

100

97

83

80

77

74

30

125.0

19.5

95

92

75

72

75

72

26

155.5

21.9

94

91

72

69

73

70

26

175.0

23.3

93

90

70

67

72

69

25

200.0

25.0

92

89

67

64

71

68

25

250.0

28.1

90

87

62

59

69

66

24

300.0

30.9

89

86

58

55

67

64

24

450.0

38.3

87

84

48

45

64

61

23

600.0

44.8

85

82

40

37

61

58

22

750.0

52.0

83

80

31

28

59

56

21

900.0

59.4

82

79

23

20

58

55

20

1000.0

63.1

80

77

17

14

57

54

20

168
www.DrakaMOG.com

D91qfci.e28
Page 1 of 2

Fire resistant QFCI-I/O/RM-JM/-

F1

Indoor and outdoor.


Fire resistant
Flame retardant halogen-free
Loose tube

QFCI-I/O/RM-JM/NEK 606 Code F1


Optical cable for indoor and outdoor use in vital communication and
emergency systems that need to be operational during fire. The
cable has a patented design that ensures operation for more than 3
hours in fires up to 1000C. The cable is halogen free and flame
retardant to protect against secondary damage to electronic
equipment during and after fire. Outer sheath is made from black
UV-stabilized and weather resistant material and may be exposed
for shorter periods to fluids such as diesel and mineral oils. The
resistance to these fluids is according to IEC60811-2-1. The cable
is reinforced with a steel wire braiding. The fibres are protected in
jelly filled loose tubes stranded around a central strength member
to ensure optimum performance and long life. Each fibre and loose
tube is colour coded for easy identification during splicing and
termination. The outer sheath is marked to show fibre type and
cable type.

Fibres in mica wrapped


loose tube
Steel strength element
Wrapping
Inner sheath
Filler
Steel wire braiding
Outer sheath

Weight and dimensions


Number of
fibres
4
8
12
24
48

Number of
fibres in each
tube
2
4
4
4
8

Number of
tubes + fillers
2+4
2+4
3+3
6+0
6+0

Loose tube
diameter
(mm)
2.2
2.2
2.2
2.2
2.2

Outer
diameter
(mm)
13.5
13.5
13.5
13.5
13.5

Weight

Heat release

(kg/km)
260
260
260
260
260

(MJ/km)
1390
1381
1324
1138
1138

Other fibre counts are available on request.

Cable properties
Tensile strength (IEC 60794-1-2E1)
Max tensile load during installation
Max tensile load during operation

Chemical reistance
1500 N Mineral oils IRM 902 (IEC60811-2-1)
500 N
Diesel - IRM 903 (IEC60811-2-1)

Crush (IEC 60794-1-2E3)


Impact (IEC 60794-1-2E4)
Torsion (IEC 60794-1-2E7)

Cable bend (IEC 60794-1-2E11)


Temperature window
Operation
Installation
Storage

- 7 days/23C
- 4 hours/70C

3000 N/10cm Fire and smoke classifications


30J
1 turn/1m

IEC 60331-25 (750C, 90 minutes)

<1.0 dB excess loss

Upgraded IEC 60331-25 (1000C, 3 hours)

<1.5 dB excess loss

BP GS 112-2 Clause7.1

Cable bending
Minimum bending diameter

- 7 days/23C
- 4 hours/70C

250 mm
<0.1dB/ 5 turn

IEC 61034
IEC 60332-3-22 (Cat. A)
IEC 60332-3-24 (Cat. C)
IEC 60754-1

-40C to +70C
-10C to +70C
-40C to +70C

IEC 60754-2

www.drakaMOG.com
169

D91qfci.e28
Page 2 of 2

Fire resistant QFCI-I/O/RM-JM/-

F1

Ordering information
9/125 fibre(SMF652D), Black*
Part no.

Cable code

50/125 fibre(MMF50HiCap), Black*


Part no.

Cable code

694150 G12-9/125 QFCI-I/O/RM-JM/694152 G12-50/125 QFCI-I/O/RM-JM/694180 G24-9/125 QFCI-I/O/RM-JM/694182 G24-50/125 QFCI-I/O/RM-JM/694139 G48-9/125 QFCI-I/O/RM-JM/694169 G48-50/125 QFCI-I/O/RM-JM/*)-Standard colour of outer sheath
We reserve the right to alter this specification without notice.

62.5/125 fibre(MMF62HiCap), Black*


Part no.
694124
694144
694154
694184
694189

Cable code
G4-62.5/125 QFCI-I/O/RM-JM/G8-62.5/125 QFCI-I/O/RM-JM/G12-62.5/125 QFCI-I/O/RM-JM/G24-62.5/125 QFCI-I/O/RM-JM/G48-62.5/125 QFCI-I/O/RM-JM/-

Optical fibres
Fibre type
Reference(DNK)
IEC60793-2-50 category
IEC11801 classification
ITU-T type
Gigabit Ethernet maximum
distances
SX-serial(850 nm)
LX-serial(1310 nm)
10Gigabit Ethernet maximum
distances
SX-serial(850 nm)
LX-serial(1310 nm)
Core diameter
Mode field diameter
Cladding diam. loose tube
Cladding diam. tight buffer
Primary coating diameter
(nominal)
Attenuation
(Typical values)
850 nm
1300 nm
1310 nm
1550 nm
Attenuation
(Maximum values)
850 nm
1300 nm
1310 nm
1550 nm
Bandwidth(OFL*)
850 nm
1300 nm
Chromatic Dispersion
1285-1330 nm
1550 nm
Polarization Mode Disp.
PMD Link Design Value **
Max. Individual Fibre
Numerical aperture
Minimum permanent bending
diameter

HiCap
50/125
MMF50HiCap

9/125
SMF652D
B.1.3
OS1 and OS2
G652.D

MaxCap
HiCap 62.5/125
50/125
MMF50MaxCap
MMF62HiCap
A1a
A1a.2
A1b
OM2
OM3
OM1
G651
G651
-

750 m
2000 m

900 m
550 m

500 m
1000 m

110 m

300 m

65 m

50 2.5 m

50 2.5 m

62.5 2.5 m

125 2.0 m
125 2.0 m
250 m

125 2.0 m
125 2.0 m
250 m

125 2.0 m
125 2.0 m
250 m

2.5 dB/km
0.7 dB/km

2.5 dB/km
0.7 dB/km

3.0 dB/km
0.7 dB/km

2.7 dB/km
0.8 dB/km

2.7 dB/km
0.9 dB/km

3.2 dB/km
1.0 dB/km

>600 MHzkm
>1200 MHzkm

>1500 MHzkm
>500 MHzkm

>200 MHzkm
>600 MHzkm

0.06 km
0.1 km
0.13 ( nominal)

0.200 0.015

0.200 0.015

0.275 0.015

50 mm

50 mm

50 mm

50 mm

5000m

10000 m
See mode field diameter
1310 nm 9.2 0.4 m
1550 nm 10.3 0.5 m
125 0.7 m
125 0.7 m
242 7 m

0.33 0.37 dB/km


0.19 0.23dB/km

0.40 dB/km
0.25 dB/km

3 ps/nmkm
18 ps/nmkm

* Over Filled Launch methode(OFL). Modal Bandwidth in accordance with IEC60793-1-41.


** According to IEC 60794-3, Ed.3 (Q=0.01%)
Other fibre types and qualities are available on request.

www.drakaMOG.com
170

Rev: 09/07

S611T MARINE FIBER OPTIC CABLE


Fiber Optic Cable - Tight buffer construction
Standards applied
Construction
Performance requir.

Application

IEC 60794-1,2,3
IEEE 802.3z (Gigabit Ethernet)

Fire Rating Standards

The Draka S611T series of Marine and Offshore


Halogen Free
fiber optic cables is designed especially for the
Low smoke
harsh environments of commercial marine vessels, Flame propagation
oil platforms and other similar applications. Draka
Toxicity
S611T low smoke/zero halogen, flame retardant
Fire retardant
cables offer the versatility and ease of use of our
other offshore cables in a construction suited for
Approvals
marine applications. They are complaint with the
latest IEC requirements. S611T cables meet the
Det Norske Veritas
requirements of IEC 60793-1 and IEC 60793-2
(DNV)
specifications, are encapsulated in all dielectric,
American Bureau of
tight buffered construction, individually reinforced
Shipping (ABS)
with aramid yarns and jacketed (breakout style).
Lloyds Registry of
The break-out components are cabled around a
Shipping (LR)
central member providing additional tensile
strength to the entire construction. The
thermoplastic low smoke/ zero halogen jacketing
system offers good resistance to chemicals, fluids,
fungus and abrasion. This product is also available
in an armoured version.

IEC 60754-1,2
IEC 61034-1,2
IEC 60332-1-25
NES 713
IEC 60332-3-22 (Cat.A)
IEEE 1202

Certificate E-7154
Certificate 01-NY6461-X
Certificate 00/00157E1

Construction

Fibre

Possible fibre types; 62.5 m MULTIMODE, 50 m MULTIMODE, 200 m


MULTIMODE or 8.3 m SIGNLEMODE.

Cladding

Multimode or singlemode fibres with an easily-strippable 900 m tight buffered


colored per TIA/EIA 598.

Cable lay up

Tight buffered tubes stranded around a central strength member of dielectric


material (epoxy/fibreglass rod).

Tube filling

Subunit strength member of aramid yarn.

Tube

LSHF, colored acc. to TIA/EIA 598.

Overall wrapping

PET-foil

Sheath

LSHF, black

Fiber performance
171

62.5m
50m
200m
8.3m
MULTIMODE
MULTIMODE
MULTIMODE
SINGLEMODE
Fiber Designation
62X
50H
200S
010X
Application specs.
IEC 60793-2 Type ITU G.651 & IEC ITU G.651 & IEC ITU G.652 C & D
A1b
60793-2 Type A1a 60793-2 Type A1a req. & IEC 60793-2
Type B1.1
Fiber type
Graded Index
Graded Index
Step Index
Matched Clad
Core diameter
62.5m + 2.5m
50m + 2.5m
200m + 5m
8.3m Nominal
Cladding diameter
125m + 1m
125m + 1m
230m + 10m
125m + 1m
Coating diameter
242m + 7m
242m + 7m
500m + 30m
242m + 7m
Buffer diameter
900m + 50m
900m + 50m
900m + 50m
900m + 50m
Numerical aperture
0.275 + 0.015
0.200 + 0.015
0.37 nominal
N/A
Mode field diameter
N/A
N/A
N/A
9.1m + 0.4m
Attenuation
820 Nm
N/A
N/A
< 12.0 dB/km
N/A
850 Nm
< 3.5 dB/km
< 3.5 dB/km
N/A
N/A
1300 Nm
< 1.0 dB/km
< 1.0 dB/km
N/A
< 0.70 dB/km
1550 Nm
N/A
N/A
N/A
< 0.70 dB/km
Bandwidth
820 Nm
N/A
N/A
< 20 MHz/km
N/A
850 Nm
< 200 MHz/km
< 500 MHz/km
N/A
N/A
1300 Nm
< 500 MHz/km
< 500 MHz/km
N/A
N/A
Dispersion
1285-1330 Nm
N/A
N/A
N/A
< 3.0 ps/nm.km
1550 Nm
N/A
N/A
N/A
< 18 ps/nm.km
Proof test
100,000 psi
100,000 psi
150,000 psi
100,000 psi

Mechanical Properties
Temperature range, during installation
during operation
storage
Crush (IEC 60794-1-2E3)
Impact (IEC 60794-1-2E4)
Torsion (IEC 60794-1-2E7)
Cable bending,
Cable bend
(IEC 60794-1-2E11)

-10C to +60C
-20C to +80C
-40C to +80C
3000 N/10cm
20 impacts, 5J
+ 1 turn/2 m, 100 cycles
< 0.1 dB / + 6 turns

Technical Data
Prod.number Draka
Comteq

S611T-02R-xxy
S611T-04-xxy
S611T-06-xxy
S611T-08-xxy
S611T-10-xxy
S611T-12-xxy
S611T-16-xxy
S611T-18-xxy
S611T-24-xxy
S611T-36-xxy
S611T-48-xxy

Number of
fibers

2
4
6
8
10
12
16
18
24
36
48

INSTALLATION

OPERATING

Outer diameter

Weight of
cable approx.

Pull strength

Bend radius

Tension

Bend radius

(N)

(mm)

(N)

(mm)

(mm)

(N)

600
600
600
600
600
600
2700
2700
2700
2700
2700

12.8
14.6
17.0
19.4
22.0
24.4
25.7
25.7
29.6
34.0
46.0

200
200
200
200
200
200
600
600
600
600
600

6.4
7.3
8.5
9.7
11.0
12.2
12.8
12.8
14.8
17.0
23.1

6.4
7.3
8.5
9.7
11.0
12.2
12.8
12.8
14.8
17.0
23.0

45
51
71
93
119
149
150
148
356
484
600

Replace the xxy with the Fiber designation in the fiber performance table above
NOTE: Fibers are not suitable for F07 crimp and cleave connector
Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications

www.DrakaMOG.com
172

S670T ARMOURED MARINE FIBER OPTIC CABLE


Fiber Optic Cable Armoured tight buffer construction
Standards applied
Construction
Performance requir.

Application

IEC 60794-1,2,3
IEEE 802.3z (Gigabit Ethernet)

Fire Rating Standards

The Draka S670T series of Marine and Offshore


Halogen Free
fiber optic cables is designed especially for the
Low smoke
harsh environments of commercial marine vessels, Flame propagation
oil platforms and other similar applications. Draka
Toxicity
S670T low smoke/zero halogen, flame retardant
Fire retardant
cables offer the versatility and ease of use of our
other offshore cables in a construction suited for
Approvals
marine applications. They are complaint with the
latest IEC requirements. S670T cables meet the
Det Norske Veritas
requirements of IEC 60793-1 and IEC 60793-2
(DNV)
specifications, are encapsulated in all dielectric,
American Bureau of
tight buffered construction, individually reinforced
Shipping (ABS)
with aramid yarns and jacketed (breakout style).
Lloyds Registry of
The thermoplastic low smoke/ zero halogen
Shipping (LR)
jacketing system offers good resistance to
chemicals, fluids, fungus and abrasion. This
product is also available in a non-armoured
version.

IEC 60754-1,2
IEC 61034-1,2
IEC 60332-1-25
NES 713
IEC 60332-3-22 (Cat.A)
IEEE 1202

Certificate E-7155
Certificate 01-NY6461-X
Certificate 00/00157E1

Construction

Fibre

Possible fibre types; 62.5 m MULTIMODE, 50 m MULTIMODE, 200 m


MULTIMODE or 8.3 m SIGNLEMODE.

Cladding

Multimode or singlemode fibres with an easily-strippable 900 m tight buffered


colored per TIA/EIA 598.

Cable lay up

Tight buffered tubes stranded around a central strength member of dielectric


material (epoxy/fibreglass rod).

Tube filling

Subunit strength member of aramid yarn.

Tube

LSHF, colored acc. to TIA/EIA 598.

Overall wrapping PET-foil under a filling of aramid yarns


Inner sheath

LSHF, black

Overall screen

Bare bronze wire braiding in acc. with IEEE 1580(2001)

Outer sheath

LSHF, black
173

Fiber performance
62.5m
50m
200m
8.3m
MULTIMODE
MULTIMODE
MULTIMODE
SINGLEMODE
Fiber Designation
62X
50H
200S
010X
Application specs.
IEC 60793-2 Type ITU G.651 & IEC ITU G.651 & IEC ITU G.652 C & D
A1b
60793-2 Type A1a 60793-2 Type A1a req. & IEC 60793-2
Type B1.1
Fiber type
Graded Index
Graded Index
Step Index
Matched Clad
Core diameter
62.5m + 2.5m
50m + 2.5m
200m + 5m
8.3m Nominal
Cladding diameter
125m + 1m
230m + 10m
125m + 1m
125m + 1m
Coating diameter
242m + 7m
242m + 7m
500m + 30m
242m + 7m
Buffer diameter
900m + 50m
900m + 50m
900m + 50m
900m + 50m
Numerical aperture
0.275 + 0.015
0.200 + 0.015
0.37 nominal
N/A
Mode field diameter
N/A
N/A
N/A
9.1m + 0.4m
Attenuation
820 Nm
N/A
N/A
< 12.0 dB/km
N/A
850 Nm
< 3.5 dB/km
< 3.5 dB/km
N/A
N/A
1300 Nm
< 1.0 dB/km
< 1.0 dB/km
N/A
< 0.70 dB/km
1550 Nm
N/A
N/A
N/A
< 0.70 dB/km
Bandwidth
820 Nm
N/A
N/A
< 20 MHz/km
N/A
850 Nm
< 200 MHz/km
< 500 MHz/km
N/A
N/A
1300 Nm
< 500 MHz/km
< 500 MHz/km
N/A
N/A
Dispersion
1285-1330 Nm
N/A
N/A
N/A
< 3.0 ps/nm.km
1550 Nm
N/A
N/A
N/A
< 18 ps/nm.km
Proof test
100,000 psi
100,000 psi
150,000 psi
100,000 psi

Mechanical Properties
Temperature range, during installation
during operation
storage
Crush (IEC 60794-1-2E3)
Impact (IEC 60794-1-2E4)
Torsion (IEC 60794-1-2E7)
Cable bending,
Cable bend
(IEC 60794-1-2E11)

-10C to +60C
-20C to +80C
-40C to +80C
3000 N/10cm
20 impacts, 5J
+ 1 turn/2 m, 100 cycles
< 0.1 dB / + 6 turns

Technical Data
Prod.number Draka
Comteq

S670T-02R-xxy
S670T-04-xxy
S670T-06-xxy
S670T-08-xxy
S670T-10-xxy
S670T-12-xxy
S670T-16-xxy
S670T-18-xxy
S670T-24-xxy
S670T-36-xxy
S670T-48-xxy

Number of
fibers

2
4
6
8
10
12
16
18
24
36
48

INSTALLATION

OPERATING

Outer diameter

Weight of
cable approx.

Pull strength

Bend radius

Tension

Bend radius

(N)

(mm)

(N)

(mm)

(mm)

(N)

600
600
600
600
600
600
2700
2700
2700
2700
2700

21.4
23.0
25.6
28.0
30.6
33.0
34.4
34.4
38.0
43.7
58.9

200
200
200
200
200
200
600
600
600
600
600

10.7
11.5
12.8
14.0
15.3
16.5
17.2
17.2
19.0
21.8
21.8

10.7
11.5
12.8
14.0
15.3
16.5
17.2
17.2
19.0
21.8
28.9

223
230
260
278
310
381
408
402
484
566
1083

Replace the xxy with the Fiber designation in the fiber performance table above
NOTE: Fibers are not suitable for F07 crimp and cleave connector
Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications

www.DrakaMOG.com
174

SIENOPYR-FR-PROFIBUS M-02Y(St)CHX 100V


Profibus cable for ships and offshore units
Standards applied
Germany
Europe

DIN 19245-3
EN 50170-Vol.2 PROFIBUS

Application

Fire Rating Standards

As a bus cable for fixed installation on board ships


and offshore units in all locations and on open
decks. The cable is not suitable for continues use
in water.

Halogen Free
Low smoke
Ozone resistance
Fire retardant

IEC 60754-2
IEC 61031
IEC 61031
IEC 60332-3-24 (cat. C)

Construction
Conductor

Stranded bare copper wire 0.35 mm (AWG22/7)

Insulation

Foam-skin Polyethylene (Foam-PE)

Core identification

a core: red, b core: green

Cable lay up

Laying of the cores with two dummies

Overall sheath

PET-foil

Overall screen

Laminated aluminium-foil under a copper braid, tinned

Inner sheath

FRNC, 8.0 mm

Outer sheath

FRNC, black 10.8 mm

Sheath marking

year SIENOPYR-FR-PROFIBUS M-02Y(St)CHX 1x2x0,35 mm 100V, 150

Technical Data
Prod.number
Draka Comteq

Designation

CD7677650 SIENOPYR-FR-PROFIBUS

No. of cores
and
cond.area

Outer
diameter

Weight of
cable approx.

Copper
content

Tensile force

(mm2)

(mm)

(kg/km)

(kg/km)

(N)

1x2x0.35

10.8

175

70

Mechanical Properties
Bending radius
Temperature range,

during operation
during installation
Resistance to chemicals
(test to VG 95218 part 2)

100 mm without load


200 mm with load
-40C upto + 80C
-10C upto + 50C
Diesel fuel to DIN VDE 51601
ASTM oil No. 2 to DIN 53521
Oils, NATO code 0-178, BW-TL 9150-0031/2 to VG 95214 part 4
Hydraulic fluids, NATO code H-515, BW-TL 9150-0020 to VG
95214 part 4
Solvent cleansing agents, BW-TL 6850-0017 to VG 95214 part 4
De-ionized water to VG 95214 part 4
De-ionized water with 3,5% NaCl.

Electrical Properties (at 20C 5C)


DC loop resistance
Mutual capacitance (at 800 Hz)
Characteristic impedance (at 9.6 kHz)
.
(at 38.4 kHz)
.
(3-20 MHz)
Insultion resistance
Nominal voltage

110 /km
30 nF/km
(250 25)
(185 18.5)
(150 15)
> 16 G.km
110 Veff

Nominal transmission characteristics (at 20 C)


f

Attenuation

(MHz)

(dB/100m)

0.0096

0.3

0.0384

0.5

4.0

2.2

16.0

4.5

www.DrakaMOG.com
Datacomm01_Jan_07
176

ToughCat S/STP 4x2x0,6 (AWG 24/7) LSHF-FR


Shielded 100 Data cable ISO/IEC 11801 CAT-5e
Standards applied
ISO/IEC 11801 2nd ed.
ANSI/EIA/TIA 568A
NEN-EN 50173
NEN 11156-5 (IEC 61156)
NEN-EN 50288-2-1
CEI 20.34 4h 70C IRM902

International
USA
Europe
Cat 5e
Construction
Oil-resistance

Application

Fire Rating Standards

This Cat.5e S/STP cable is meant for use as


horizontal cable in tougher electrical and has
stranded copper conductors arranged in
individually foil screened twisted pairs. All four pairs
have a common braid. The susceptibility of noise is
very low because of excellent shielding
performance. Because of this, the cable can also
be used in Class F (Cat.7) installations up to 70 m.
Permanent links.

Halogen Free
Low smoke
Flame propogation
Fire retardant

IEC 60754-2
IEC 61034-1,2
IEC 60332-1
IEC 60332-3-24 (cat. C)

Specifications
Det Norske Veritas (DNV)
Lloyds Registar (LR)
Germanischer Lloyds (GL)

Construction
Conductor

Bare copper wire 0.60 mm (AWG24/7)

Insulation

Polyethylene, 1.4 mm

Twisting

2 cores to the pair

Pair screen

4 pairs

Cable lay up

Al-laminated plastic foil around each pair

Overall sheath

Copper braid, tinned

Sheath

Oil resistant, fire retardant and halogen free LSHF-FR, grey RAL 7035

Core identification
(in accordance ISO/IEC 11801 2nd edition)
Pair 1
white/blue and blue,
Pair 2
white/orange and orange,
Pair 3
white/green and green,
Pair 4
white/brown and brown

Technical Data
Prod.number
Draka Comteq

Designation

No. of cores
and
cond.area

Outer
diameter

Fire Load

(mm2)

(mm)

(MJ/km) (kWh/m)

CNS792621 ToughCat S-STP LSHF-FR 2x2x0.60


177

7.8

462

0.128

Weight of
cable
approx.

Copper
content

Tensile
force

(kg/km)

(kg/km)

(N)

44

33

100

Mechanical Properties
Bending radius
Temperature range,

during operation
during installation

25 mm without load
50 mm with load
-20C upto + 85C
0C upto + 50C

Electrical Properties (at 20C 5C)


DC loop resistance
Resistance unbalance
Insulation resistance (500 V)
Capacitance at 800 Hz
Capacitance unbalance (pair to ground)
Characteristic impedance (1-100 MHz)
(100-250 MHz)
Nominal velocity of propagation
Propagation delay
Delay skew
Test voltage (DC, 1 min)
Core/Core and Core/Screen
Transfer impedance
at 1 MHz
at 10 MHz
at 30 MHz

158 /km
2%
2000 M *km
nom. 43 nF/km
1500 pF/km
(100 15)
(100 18)
approx. 75 %
450 ns/100m
15 ns/100m
1000 V
10 m /m
8 m /m
10 m /m

Nominal transmission characteristics acc. to Category 7 (at 20 C)


f

Attenuation

NEXT

PS-ACR

PS-NEXT

ELFEXT

PS-ELFEXT

Return loss

(MHz)

(dB/100m)

(dB)

(dB)

(dB/100m)

(dB/100m)

(dB/100m)

(dB)

1.0

2.1

90

85

87

85

82

23

4.0

4.0

90

83

87

85

82

24

10.0

6.3

90

81

87

79

76

25

16.0

8.0

90

79

87

75

72

25

20.0

9.0

90

78

87

73

70

25

31.2

11.4

90

76

87

69

66

25

62.5

16.5

86

67

83

63

60

23

100.0

21.3

83

59

80

59

56

21

125.0

24.2

81

54

78

57

54

20

200.0

31.5

78

44

75

53

50

18

250.0

35.8

77

38

74

51

48

18

400.0

47.1

73

23

70

47

44

17

600.0

60.1

71

68

44

41

17

www.DrakaMOG.com
178

Datacomm13_Jan_07

Opmaak Control Cables 27-07-2001 15:16 Pagina 14

Power and control cables


HXXM EEP 0.6/1 kV IEC 60092-3
Class 2 conductors

Application:

Identification of the cores:

Unarmored power and control cables 0.6/1 kV with special


properties for electrical installations in ships and offshore
units. Temperature Class 85 C, Flame Retardant
(IEC 60332-3 category A, A/F), Low Smoke, Halogen
Free, Low Toxicity. Suitable for application in cold climate
areas required to pass cold bend and cold impact testing
at 40 C and 35 C, respectively.

1 core
2 cores
3 cores
4 cores
5 cores and up:

Generally according to IEC 60092-3 0.6/1 kV


Conductors:

Insulation:

Assembly:
Filler:
Sheathing:

Sheathing color:

Special cable properties:


Fire propagation:
Smoke:

Construction:

Acidity:

stranded bare annealed


copper, IEC 60228, (Class 2)
sizes 1 - 300 mm2
cross linked polyethylene (XLPE/
HF XLPE) according to IEC 60092-3,
IEC 60092-351 and IEEE Std 45
cores cabled together
halogen free filling compound
halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

14

179

black
black, blue
black, blue, brown
black, blue, brown, green/yellow
black, numbered

Halogen content:
Toxicity index:
Cold properties:

IEC 60332-3 category A, A/F


IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92

Opmaak Control Cables 27-07-2001 15:16 Pagina 15

General data for HXXM EEP 0.6/1 kV EEP IEC 60092-3


Class 2 conductors
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 2
(n)

nominal
conductor
diameter

nominal
core
diameter

nominal
outer
diameter

nominal
outer
diameter

minimum
bending
radius

approximate
weight

approximate
weight

(mm)

1 x 1.5
1 x 2.5
1x 4
1x 6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300

7
7
7
7
7
7
7
19
19
19
19
37
37
37
61
61

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4
13.9
15.5
17.3
19.9
22.2

2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x

1.5
2.5
4
6
10
16
25
35
50
70
95

7
7
7
7
7
7
7
19
19
19
19

3 x 1.5
3 x 2.5
3x 4
3x 6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240

conductor
resistance
at 20 C DC

conductor
resistance
at 20 C DC

(mm)

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

3.4
3.9
4.6
5.2
6.2
7.5
9.0
9.7
11.0
13.0
15.0
17.7
19.5
21.5
24.5
27.3

0.220
0.236
0.268
0.287
0.339
0.386
0.457
0.484
0.642
0.728
0.811
0.929
1.028
1.106
1.248
1.366

5.6
6.0
6.8
7.3
8.6
9.8
11.6
12.3
16.3
18.5
20.6
23.6
26.1
28.1
31.7
34.7

28
30
34
37
43
49
58
74
98
111
124
142
157
169
190
208

29
37
50
63
101
141
215
276
437
591
779
974
1,189
1,445
1.881
2.298

43
55
75
94
150
210
320
410
650
880
1,160
1,450
1,770
2,150
2,800
3,420

3.7
2.26
1.41
0.94
0.56
0.35
0.222
0.160
0.118
0.082
0.059
0.047
0.038
0.0302
0.0230
0.0183

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4

3.4
3.9
4.6
5.2
6.2
7.5
9.0
9.7
11.0
13.0
15.0

0.394
0.437
0.500
0.563
0.661
0.783
0.909
0.969
1.079
1.280
1.445

10.0
11.1
12.7
14.3
16.8
19.9
23.1
24.6
27.4
32.5
36.7

50
56
76
86
101
119
139
148
164
195
220

101
128
175
228
329
484
706
874
1,109
1,546
2,083

150
190
260
340
490
720
1,050
1,300
1,650
2,300
3,100

3.7
2.26
1.41
0.94
0.56
0.35
0.222
0.160
0.118
0.082
0.059

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193

7
7
7
7
7
7
7
19
19
19
19
37
37
37
61

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4
13.9
15.5
17.3
19.9

3.4
3.9
4.6
5.2
6.2
7.5
9.0
9.7
11.0
13.0
15.0
17.7
19.5
21.5
24.5

0.417
0.461
0.528
0.594
0.701
0.815
0.953
1.039
1.165
1.354
1.547
1.791
1.976
2.165
2.449

10.6
11.7
13.4
15.1
17.8
20.7
24.2
26.4
29.6
34.4
39.3
45.5
50.2
55.0
62.2

53
59
80
91
107
124
145
158
178
206
236
273
301
330
373

114
141
195
262
396
564
840
1,075
1,411
1,915
2,621
3,326
4,099
5,006
6,518

170
210
290
390
590
840
1,250
1,600
2,100
2,850
3,900
4,950
6,100
7,450
9,700

3.7
2.26
1.41
0.94
0.56
0.35
0.222
0.160
0.118
0.082
0.059
0.047
0.038
0.0302
0.0230

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754

4 x 1.5
4 x 2.5
4x 4
4x 6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150

7
7
7
7
7
7
7
19
19
19
19
37
37

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4
13.9
15.5

3.4
3.9
4.6
5.2
6.2
7.5
9.0
9.7
11.0
13.0
15.0
17.7
19.5

0.461
0.504
0.583
0.634
0.772
0.902
1.051
1.130
1.287
1.504
1.717
1.992
2.189

11.7
12.8
14.8
16.1
19.6
22.9
26.7
28.7
32.7
38.2
43.6
50.6
55.6

59
77
89
97
118
137
160
172
196
229
262
304
334

134
168
242
302
484
706
1,008
1,310
1,747
2,385
3,293
4,166
5,107

200
250
360
450
720
1,050
1,500
1,950
2,600
3,550
4,900
6,200
7,600

3.7
2.26
1.41
0.94
0.56
0.35
0.222
0.160
0.118
0.082
0.059
0.047
0.038

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124

5 x 1.5
5 x 2.5
5x 4
5 x 25

7
7
7
7

1.6
2.0
2.5
6.3

3.4
3.9
4.6
9.0

0.504
0.555
0.634
1.185

12.8
14.1
16.1
30.1

77
85
97
181

148
202
282
1,243

220
300
420
1,850

3.7
2.26
1.41
0.222

12.1
7.41
4.61
0.727

24 x

1.3

3.1

0.858

21.8

131

349

520

5.5

18.1

7x
24 x
37 x

1.5
1.5
1.5

7
7
7

1.6
1.6
1.6

3.4
3.4
3.4

0.516
0.949
1.102

13.1
24.1
28.0

79
145
168

148
470
672

220
700
1,000

3.7
3.7
3.7

12.1
12.1
12.1

7x

2.5

2.0

3.9

0.575

14.6

88

202

300

180

2.26

7.41

Opmaak Control Cables 27-07-2001 15:16 Pagina 16

Power and control cables


HXXM EEP 0.6/1 kV IEC 60092-3
Class 5 conductors

Application:

Identification of the cores:

Unarmored power and control cables 0.6/1 kV with special


properties for electrical installations in ships and offshore
units.
Temperature Class 85 C, Flame Retardant (IEC 60332-3
category A, A/F), Low Smoke, Halogen Free, Low
Toxicity. Suitable for application in cold climate areas
required to pass cold bend and cold impact testing at
40 C and 35 C, respectively.

1 core
2 cores
3 cores
4 cores

Construction:

Acidity:

Generally according to IEC 60092-3 0.6/1 kV


Conductors:

Insulation:

Assembly:
Filler:
Sheathing:

Sheathing color:

Special cable properties:


Fire propagation:
Smoke:

Halogen content:

flexible bare annealed


copper, IEC 60228, (Class 5)
sizes 1 - 300 mm2
cross linked polyethylene (XLPE/
HF XLPE) according to IEC 60092-3,
IEC 60092-351 and IEEE Std 45
cores cabled together
halogen free filling compound
halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

16

181

black
black, blue
black, blue, brown
black, blue, brown, green/yellow

Toxicity index:
Cold properties:

IEC 60332-3 category A, A/F


IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92

Opmaak Control Cables 27-07-2001 15:16 Pagina 17

General data for HXXM EEP 0.6/1 kV IEC 60092-3


Class 5 conductors
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 5
(n)

nominal
conductor
diameter

nominal
core
diameter

nominal
outer
diameter

nominal
outer
diameter

minimum
bending
radius

approximate
weight

approximate
weight

conductor
resistance
at 20 C DC

conductor
resistance
at 20 C DC

(mm)

(mm)

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

266
380
330
437
562
703
851
1,117
1,384

8.2
9.8
11.6
13.1
15.4
17.1
18.5
21.3
23.7

11.0
12.8
15.1
16.8
19.2
21.2
22.8
26.0
28.8

0.535
0.713
0.811
0.886
0.988
1.094
1.165
1.307
1.429

13.6
18.1
20.6
22.5
25.1
27.8
29.6
33.2
36.3

82
109
124
135
151
167
178
199
218

286
474
638
806
1,008
1,257
1,478
1.951
2.318

425
705
950
1,200
1,500
1,870
2,200
2,850
3,450

0.169
0.118
0.083
0.063
0.049
0.039
0.032
0.0244
0.0195

0.544
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
0.0641

35
50
70
95

266
380
330
437

8.2
9.8
11.6
13.1

11.0
12.8
15.1
16.8

1.067
1.228
1.437
1.587

27.1
31.2
36.5
40.3

163
187
219
242

941
1,277
1,767
2,231

1,400
1,900
2,630
3,320

0.169
0.118
0.083
0.063

0.554
0.386
0.272
0.206

3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240

266
380
330
437
562
703
851
1,117

8.2
9.8
11.6
13.1
15.4
17.1
18.5
21.3

11.0
12.8
15.1
16.8
19.2
21.2
22.8
26.0

1.154
1.315
1.543
1.701
1.929
2.122
2.272
2.579

29.3
33.4
39.2
43.2
49.0
53.9
57.7
65.5

176
200
235
259
294
323
346
393

1,159
1,566
2,184
2,779
3,548
4,368
5,157
6,703

1,725
2,330
3,250
4,135
5,280
6,500
7,675
9,975

0.169
0.118
0.083
0.063
0.049
0.039
0.032
0.0244

0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801

4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150

266
380
330
437
562
703

8.2
9.8
11.6
13.1
15.4
17.1

11.0
12.8
15.1
16.8
19.2
21.2

1.272
1.457
1.709
1.890
2.146
2.354

32.3
37.0
43.4
48.0
54.5
59.8

194
222
260
288
327
359

1,428
1,939
2,715
3,464
4,428
5,433

2,125
2,885
4,040
5,155
6,590
8,085

0.169
0.118
0.083
0.063
0.049
0.039

0.554
0.386
0.272
0.206
0.161
0.129

1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
2x
2x
2x
2x

182

General data for HXXM-FR EEP 0.6/1 kV IEC 60092-3


Class 2 conductors
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 2
(n)

nominal
conductor
diameter

nominal
core
diameter
(mm)

nominal
diameter
over
sheath
(inches)

nominal
diameter
over
sheath
(mm)

(mm)

1 x 1.5
1 x 2.5
1x 4
1x 6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300

7
7
7
7
7
7
7
19
19
19
19
37
37
37
61
61

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4
13.9
15.5
17.3
19.9
22.2

2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x

1.5
2.5
4
6
10
16
25
35
50
70
95

7
7
7
7
7
7
7
19
19
19
19

3 x 1.5
3 x 2.5
3x 4
3x 6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240
4 x 1.5
4 x 2.5
4x 4
4x 6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150

4.3
4.7
5.5
6.0
7.1
8.3
9.8
10.6
11.9
13.9
15.8
18.6
20.3
22.3
25.4
28.1

0.252
0.272
0.299
0.319
0.370
0.421
0.492
0.520
0.677
0.764
0.846
0.961
1.059
1.150
1.283
1.398

6.4
6.9
7.6
8.1
9.4
10.7
12.5
13.2
17.2
19.4
21.5
24.4
26.9
29.2
32.6
35.5

35
43
56
71
107
151
223
287
455
612
804
986
1218
1481
1906
2328

52
64
84
105
159
224
332
427
677
911
1197
1467
1812
2204
2837
3464

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4

4.3
4.7
5.5
6.0
7.1
8.3
9.8
10.6
11.9
13.9
15.8

0.461
0.508
0.579
0.630
0.728
0.850
0.976
1.035
1.157
1.346
1.512

11.7
12.9
14.7
16.0
18.5
21.6
24.8
26.3
29.4
34.2
38.4

126
158
214
264
375
534
747
917
1184
1646
2160

187
235
318
393
558
794
1112
1364
1762
2450
3215

7
7
7
7
7
7
7
19
19
19
19
37
37
37
61

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4
13.9
15.5
17.3
19.9

4.3
4.7
5.5
6.0
7.1
8.3
9.8
10.6
11.9
13.9
15.8
18.6
20.3
22.3
25.4

0.492
0.535
0.614
0.669
0.772
0.886
1.039
1.110
1.240
1.425
1.618
1.862
2.047
2.236
2.524

12.5
13.6
15.6
17.0
19.6
22.5
26.4
28.2
31.5
36.2
41.1
47.3
52.0
56.8
64.1

141
176
243
304
436
615
899
1136
1478
2029
2728
3508
4287
5120
6659

210
262
361
453
649
915
1338
1691
2200
3020
4060
5220
6380
7620
9910

7
7
7
7
7
7
7
19
19
19
19
37
37

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4
13.9
15.5

4.3
4.7
5.5
6.0
7.1
8.3
9.8
10.6
11.9
13.9
15.8
18.6
20.3

0.543
0.583
0.661
0.713
0.854
0.980
1.142
1.236
1.366
1.583
1.799
2.071
2.272

13.8
14.8
16.8
18.1
21.7
24.9
29.0
31.4
34.7
40.2
45.7
52.6
57.7

169
208
280
348
540
758
1100
1378
1845
2554
3441
4368
5275

252
309
417
518
803
1128
1635
2050
2745
3800
5120
6500
7850

1.5
2.5
4

7
7
7

1.6
2.0
2.5

4.3
4.7
5.5

0.602
0.650
0.736

15.3
16.5
18.7

204
251
349

303
373
520

24 x

1.3

3.8

1.047

26.6

504

750

6x
7x
8x
12 x
20 x
24 x
30 x
37 x

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

7
7
7
7
7
7
7
7

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3

0.622
0.626
0.681
0.827
1.043
1.169
1.248
1.358

15.8
15.9
17.3
21.0
26.5
29.7
31.7
34.5

180
187
212
306
497
624
719
864

268
278
316
455
739
928
1070
1285

6x
7x
8x
10 x
12 x
19 x
20 x
24 x
30 x
36 x

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5

7
7
7
7
7
7
7
7
7
7

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0

4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7
4.7

0.673
0.677
0.744
0.874
0.906
1.079
1.150
1.280
1.366
1.488

17.1
17.2
18.9
22.2
23.0
27.4
29.2
32.5
34.7
37.8

227
239
276
346
398
605
648
816
943
1138

338
356
411
515
593
900
964
1215
1404
1693

13 x

3.1

6.0

30.7

827

1231

5x
5x
5x

183 1.209

approxi
mate
weight

approx
weight

(lbs/M)

(kg/km)

Opmaak Control Cables 27-07-2001 15:15 Pagina 12

Power and control cables


HXXMB EEP 0.6/1 kV IEC 60092-3
Class 5 conductors

Application:

Identification of the cores:

Armored power and control cables 0.6/1 kV with special


properties for electrical installations in ships and offshore
units. Temperature Class 85 C, Flame Retardant (IEC
60332-3 category A, A/F), Low Smoke, Halogen Free,
Low Toxicity. Suitable for application in cold climate areas
required to pass cold bent and cold impact testing at
40 C and 35 C, respectively.

1 core
2 cores
3 cores
4 cores

Special cable properties:


Fire propagation:
Smoke:

Construction:
Acidity:

Generally according to IEC 60092-3 0.6/1 kV


Conductors:

Insulation:

Assembly:
Filler:
Innersheath:
Braiding:

Sheathing:

12

Sheathing color:

flexible bare annealed


copper, IEC 60228, (Class 5)
sizes 1 - 300 mm2
cross linked polyethylene (XLPE/
HF XLPE) according to IEC 60092-3,
IEC 60092-351 and IEEE Std 45
cores cabled together
halogen free filling compound
halogen free, flame retardant
(SHF1, IEC 60092-359)
bronze wire according to IEEE Std 45,
CDA 220, weight coverage 90% on
nominal diameter according to
IEC 60092-3, wire diameter
0.32 - 0.40 mm
halogen free, flame retardant (SHF1,
IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

184

black
black, blue
black, blue, brown
black, blue, brown, green/yellow

Halogen content:
Toxicity index:
Cold properties:

IEC 60332-3 category A, A/F


IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92

Opmaak Control Cables 27-07-2001 15:15 Pagina 13

General data for HXXMB EEP 0.6/1 kV IEC 60092-3


Class 5 conductors
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 5
(n)

nominal
nominal nominal
conductor core
diameter
diameter diameter over innersheath
(mm)
(mm)
(inches)

nominal
diameter
over innersheath
(mm)

nominal
diameter
of braiding
wire
(mm)

nominal nominal minimum approxi- approxiouter


outer
bending mate
mate
diameter diameter radius
weight
weight

conductor conductor
resistance resistance
at 20 C DC at 20 C DC

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

266
380
330
437
562
703
851
1,117
1,384

8.2
9.8
11.6
13.1
15.4
17.1
18.5
21.3
23.7

11.0
12.8
15.1
16.8
19.2
21.2
22.8
26.0
28.8

0.535
0.713
0.811
0.886
0.988
1.094
1.165
1.307
1.429

13.6
18.1
20.6
22.5
25.1
27.8
29.6
33.2
36.3

0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.40
0.40

0.697
0.874
0.980
1.055
1.173
1.287
1.358
1.520
1.650

17.7
22.2
24.9
26.8
29.8
32.7
34.5
38.6
41.9

106
133
149
161
179
196
207
232
251

443
685
874
1,062
1,310
1,596
1,848
2,369
2,856

660
1,020
1,300
1,580
1,950
2,375
2,750
3,525
4,250

0.169
0.118
0.083
0.063
0.049
0.039
0.032
0.0244
0.0195

0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
0.0641

35
50
70
95

266
380
330
437

8.2
9.8
11.6
13.1

11.0
12.8
15.1
16.8

1.067
1.228
1.437
1.587

27.1
31.2
36.5
40.3

0.32
0.40
0.40
0.40

1.260
1.402
1.657
1.815

32.0
35.6
42.1
46.1

192
214
253
277

1,270
1,720
2,301
2,822

1,890
2,560
3,425
4,200

0.169
0.118
0.083
0.063

0.554
0.386
0.272
0.206

3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240

266
380
330
437
562
703
851
1,117

8.2
9.8
11.6
13.1
15.4
17.1
18.5
21.3

11.0
12.8
15.1
16.8
19.2
21.2
22.8
26.0

1.154
1.315
1.543
1.701
1.929
2.122
2.272
2.579

29.3
33.4
39.2
43.2
49.0
53.9
57.7
65.5

0.32
0.40
0.40
0.40
0.40
0.40
0.40
0.40

1.346
1.528
1.772
1.937
2.173
2.374
2.531
2.854

34.2
38.8
45.0
49.2
55.2
60.3
64.3
72.5

205
233
270
295
331
362
386
435

1,512
2,036
2,755
3,420
4,301
5,214
6,064
7,795

2,250
3,030
4,100
5,090
6,400
7,760
9,025
11,600

0.169
0.118
0.083
0.063
0.049
0.039
0.032
0.0244

0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801

4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150

266
380
330
437
562
703

8.2
9.8
11.6
13.1
15.4
17.1

11.0
12.8
15.1
16.8
19.2
21.2

1.272
1.457
1.709
1.890
2.146
2.354

32.3
37.0
43.4
48.0
54.5
59.8

0.40
0.40
0.40
0.40
0.40
0.40

1.484
1.677
1.945
2.134
2.398
2.614

37.7
42.6
49.4
54.2
60.9
66.4

226
256
296
325
365
398

1,881
2,486
3,360
4,206
5,288
6,384

2,800
3,700
5,000
6,260
7,870
9,500

0.169
0.118
0.083
0.063
0.049
0.039

0.554
0.386
0.272
0.206
0.161
0.129

1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
2x
2x
2x
2x

185

HXXM FR Power & Control cables 0.6/1 kV


Fire resistant halogen free marine cable

Max. conductor temp.: 90 C


Nominal voltage
: 0.6/1 kV

Application

Standards applied

Fire resistant power and control cables for fixed


installations in ships with special properties.

Halogen Free - According to IEC 60754-1/2


Low smoke
- According to IEC 61034-1/2
Flame retardant - According to IEC 60332-3 cat A
Toxicity index - According to NES 713
Fire resistance - According to IEC 60331

Construction
Conductor

Annealed stranded circular copper

Insulation

Mica tape and Crosslinked polyethylene, XLPE/HF XLPE to IEC 60092/3

Inner sheath

Flame retardant halogen free thermoplastic compound, SHF1

Outer sheath

Flame retardant halogen-free thermoplastic compound, SHF1

Marking text

DRAKA HXXM-FR 0,6/1kV IEC 60092-3 3 x 10 mm2


ETL Listed 9801094 (year) (code)

Outer sheath colour

Grey

Identification the cores


One core
Two cores
Three cores
Four cores
Five cores and up

Black
Black, blue
Black, blue, Brown
Black, blue. Brown, green/yellow
Black, numbered

186

RANGE AND DIMENSIONS


No. of pairs
and
Prod.number
cond.area
(mm2)

123497
123498
123499
123501
123502
123503
123504
123506
123509
123519
123521
124663

3 x 10
3 x 25
3 x 35
3 x 50
3 x 120
3 x 95
3 x 150
4 x 35
7 x 1,5
3 x 16
3 x 70
4x3x1

Cross
section
screen
(mm2)

Conductordiameter
(mm)

Corediameter
(mm)

Diameter
outer
sheath
(mm)

n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.

3.92
6.27
7.00
8.10
15.40
11.40
16.90
7.00
1.57
4.97
9.7
1.29

7.04
9.80
10.57
11.88
20.02
15.81
21.67
10.57
4.30
8.29
13.90
3.81

19.20
26.00
28.20
31.50
50.80
41.10
54.70
31.40
15.90
22.10
36.20
23.10

Diam Weight
under
of
Max.
armour cable current
(A)
mm
approx.
(kg/km)

n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
n.a.
29.7

635
1316
1685
2195
5415
4045
6475
2120
285
895
3010
485

Resistance
at 20 oC DC
(Ohm/km)

Resistance
at 90 oC 50
Hz (Ohm/km)

0.56
0.222
0.160
0.118
0.047
0.059
0.038
0.160
3.70
0.35
0.082
3.70

2.33
0.927
0.669
0.494
0.198
0.248
0.161
0.669
15.4
1.47
0.344
n.a.

65
110
137
167
301
259
347
137
20
87
214
n.a.

Installation recommendations
Minimum Bending Radius
during Installation

Minimum Bending
Radius Fixed Installed

8xD

6xD

Maximum Tensile Load


During Installation
50 N * total cross section
conductors

Minimum Installation
Temperature

1610 Greens Road, Suite 200, Houston TX 77032


Phone: 281-209-1070, Toll Free: 888-354-2225, Fax 281-851-1433
Website: www.DrakaMOG.com
187

-10 C

Opmaak Control Cables 27-07-2001 15:19 Pagina 24

Instrumentation and communication cables


HXXM EEP 0.6/1 kV IEC 60092-3
Individually shielded and isolated*

Application:

Identification of the groups:

Unarmored, individually shielded and isolated instrumentation and communication cables 0.6/1 kV with special
properties for electrical installations in ships and offshore
units. Temperature Class 85 C, Flame Retardant
(IEC 60332-3 category A, A/F), Low Smoke, Halogen
Free, Low Toxicity. Suitable for application in cold climate
areas required to pass cold bend and cold impact testing
at 40 C and 35 C, respectively.

1 pair
multi pairs

Special cable properties:

Construction:

Fire propagation:
Smoke:

According to IEC 60092-3 with enhanced properties.


Conductors:
Insulation:

Twisting:
Individual shield
and isolation:
Assembly:
Sheathing:

Sheathing color:

30

1 triad
multi triads

black, white
black, white
(groups sequential numbered
1-1, 2-2, 3-3 etc.)
black, white, red
black, white, red
(groups sequential numbered
1-1-1, 2-2-2, 3-3-3, etc.)

stranded bare annealed


copper, IEC 60228, sizes 1 - 4 mm2
cross linked polyethylene (XLPE/
HF XLPE) according to IEC 60092-3,
IEC 60092-351 and IEEE Std 45
cores twisted to a pair/triad
tinned copper drain wire; aluminum/polyester tape; polyester tape
shielded pairs/triads cabled together
halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

188

Acidity:
Halogen content:
Toxicity index:
Cold properties:

*Remark:

IEC 60332-3 category A, A/F


IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92
Other constructions available on
request

Opmaak Control Cables 27-07-2001 15:19 Pagina 25

General data for HXXM Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 2
(n)

nominal
conductor
diameter

nominal
core
diameter

nominal
outer
diameter

nominal
outer
diameter

minimum
bending
radius

approximate
weight

approximate
weight

conductor
resistance
at 20 C DC

conductor
resistance
at 20 C DC

(mm)

(mm)

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

1x2x1
2x2x1
4x2x1
7x2x1
10 x 2 x 1
12 x 2 x 1
16 x 2 x 1
19 x 2 x 1

7
7
7
7
7
7
7
7

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3

3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

0.350
0.567
0.673
0.748
0.984
1.047
1.185
1.209

8.9
14.4
17.1
19.0
25.0
26.6
30.1
30.7

45
86
103
114
150
160
181
184

57
202
296
336
504
571
739
806

85
300
440
500
750
850
1,100
1,200

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6

18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5

1 x 2 x 1.5
2 x 2 x 1.5
5 x 2 x 1.5
12 x 2 x 1.5

7
7
7
7

1.6
1.6
1.6
1.6

3.4
3.4
3.4
3.4

0.371
0.606
0.799
1.130

9.4
15.4
20.3
28.7

57
92
122
172

67
235
363
659

100
350
540
980

3.7
3.7
3.7
3.7

12.3
12.3
12.3
12.3

12 x 2 x 2.5

2.0

3.8

1.272

32.3

194

853

1.270

2.30

7.56

2x2x4

2.5

4.6

0.787

20.0

120

356

530

1.43

4.70

1x3x1

1.3

3.1

0.369

9.4

47

67

100

5.6

18.5

1 x 3 x 1.5
10 x 3 x 1.5
16 x 3 x 1.5

7
7
7

1.6
1.6
1.6

3.4
3.4
3.4

0.392
1.240
1.449

10.0
31.5
36.8

50
189
221

87
806
1,062

130
1,200
1,580

3.7
3.7
3.7

12.3
12.3
12.3

Electrical characteristics for HXXM Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
cross section of the
conductor
(mm2)

mutual capacitance
core to core (nF/M)
pair & triad

mutual capacitance
core to core (nF/km)
pair & triad

mutual capacitance
core to shield (nF/M)
pair & triad

mutual capacitance
core to shield (nF/km)
pair & triad

loop inductance
(mH/M)
pair & triad

loop inductance
(mH/km)
pair & triad

1
1.5
2.5
4

19
21
24
25

63
70
79
82

33
37
41
43

108
121
136
142

0.22
0.21
0.20
0.19

0.72
0.68
0.64
0.62

189

Opmaak Control Cables 27-07-2001 15:19 Pagina 24

Instrumentation and communication cables


HXXM EEP 250 V IEC 60092-3
Individually shielded and isolated*

Application:

Identification of the groups:

Unarmored, individually shielded and isolated instrumentation and communication cables 250 V with special
properties for electrical installations in ships and offshore
units. Temperature Class 85 C, Flame Retardant
(IEC 60332-3 category A, A/F), Low Smoke, Halogen
Free, Low Toxicity. Suitable for application in cold climate
areas required to pass cold bend and cold impact testing
at 40 C and 35 C, respectively.

1 pair
multi pairs

Special cable properties:

Construction:

Fire propagation:
Smoke:

According to IEC 60092-3 with enhanced properties.


Conductors:
Insulation:

Twisting:
Individual shield
and isolation:
Assembly:
Sheathing:

Sheathing color:

24

1 triad
multi triads

black, white
black, white
(groups sequential numbered
1-1, 2-2, 3-3 etc.)
black, white, red
black, white, red
(groups sequential numbered
1-1-1, 2-2-2, 3-3-3, etc.)

stranded bare annealed


copper, IEC 60228, sizes 1 - 4 mm2
cross linked polyethylene (XLPE/
HF XLPE) according to IEC 60092-3,
IEC 60092-351 and IEEE Std 45
cores twisted to a pair/triad
tinned copper drain wire; aluminum/polyester tape; polyester tape
shielded pairs/triads cabled together
halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

190

Acidity:
Halogen content:
Toxicity index:
Cold properties:

*Remark:

IEC 60332-3 category A, A/F


IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92
Other constructions available on
request

Opmaak Control Cables 27-07-2001 15:19 Pagina 25

General data for HXXM Individually shielded and isolated EEP 250V IEC 60092-3
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 2
(n)

nominal
conductor
diameter
(mm)

1x2x1
2x2x1
4x2x1
7x2x1
10 x 2 x 1
12 x 2 x 1
16 x 2 x 1
19 x 2 x 1

7
7
7
7
7
7
7
7

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3

1 x 2 x 1.5
2 x 2 x 1.5
5 x 2 x 1.5
12 x 2 x 1.5

7
7
7
7

1.6
1.6
1.6
1.6

12 x 2 x 2.5

2x2x4

nominal
core
diameter

nominal
outer
diameter

nominal
outer
diameter

minimum
bending
radius

approximate
weight

approximate
weight

conductor
resistance
at 20 C DC

conductor
resistance
at 20 C DC

(mm)

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1

0.350
0.567
0.673
0.748
0.984
1.047
1.185
1.209

8.9
14.4
17.1
19.0
25.0
26.6
30.1
30.7

45
86
103
114
150
160
181
184

57
202
296
336
504
571
739
806

85
300
440
500
750
850
1,100
1,200

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6

18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5

3.4
3.4
3.4
3.4

0.371
0.606
0.799
1.130

9.4
15.4
20.3
28.7

57
92
122
172

67
235
363
659

100
350
540
980

3.7
3.7
3.7
3.7

12.3
12.3
12.3
12.3

2.0

3.8

1.272

32.3

194

853

1.270

2.30

7.56

2.5

4.6

0.787

20.0

120

356

530

1.43

4.70

1x3x1

1.3

3.1

0.369

9.4

47

67

100

5.6

18.5

1 x 3 x 1.5
10 x 3 x 1.5
16 x 3 x 1.5

7
7
7

1.6
1.6
1.6

3.4
3.4
3.4

0.392
1.240
1.449

10.0
31.5
36.8

50
189
221

87
806
1,062

130
1,200
1,580

3.7
3.7
3.7

12.3
12.3
12.3

Electrical characteristics for HXXM Individually shielded and isolated EEP 250 V IEC 60092-3
cross section of the
conductor
(mm2)

mutual capacitance
core to core (nF/M)
pair & triad

mutual capacitance
core to core (nF/km)
pair & triad

mutual capacitance
core to shield (nF/M)
pair & triad

mutual capacitance
core to shield (nF/km)
pair & triad

loop inductance
(mH/M)
pair & triad

loop inductance
(mH/km)
pair & triad

1
1.5
2.5
4

19
21
24
25

63
70
79
82

33
37
41
43

108
121
136
142

0.22
0.21
0.20
0.19

0.72
0.68
0.64
0.62

191

Opmaak Control Cables 27-07-2001 15:15 Pagina 12

Power and control cables


HXXMB EEP 0.6/1 kV IEC 60092-3
Class 5 conductors

Application:

Identification of the cores:

Armored power and control cables 0.6/1 kV with special


properties for electrical installations in ships and offshore
units. Temperature Class 85 C, Flame Retardant (IEC
60332-3 category A, A/F), Low Smoke, Halogen Free,
Low Toxicity. Suitable for application in cold climate areas
required to pass cold bent and cold impact testing at
40 C and 35 C, respectively.

1 core
2 cores
3 cores
4 cores

Special cable properties:


Fire propagation:
Smoke:

Construction:
Acidity:

Generally according to IEC 60092-3 0.6/1 kV


Conductors:

Insulation:

Assembly:
Filler:
Innersheath:
Braiding:

Sheathing:

12

Sheathing color:

flexible bare annealed


copper, IEC 60228, (Class 5)
sizes 1 - 300 mm2
cross linked polyethylene (XLPE/
HF XLPE) according to IEC 60092-3,
IEC 60092-351 and IEEE Std 45
cores cabled together
halogen free filling compound
halogen free, flame retardant
(SHF1, IEC 60092-359)
bronze wire according to IEEE Std 45,
CDA 220, weight coverage 90% on
nominal diameter according to
IEC 60092-3, wire diameter
0.32 - 0.40 mm
halogen free, flame retardant (SHF1,
IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

192

black
black, blue
black, blue, brown
black, blue, brown, green/yellow

Halogen content:
Toxicity index:
Cold properties:

IEC 60332-3 category A, A/F


IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92

Opmaak Control Cables 27-07-2001 15:15 Pagina 13

General data for HXXMB EEP 0.6/1 kV IEC 60092-3


Class 5 conductors
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 5
(n)

nominal
nominal nominal
conductor core
diameter
diameter diameter over innersheath
(mm)
(mm)
(inches)

nominal
diameter
over innersheath
(mm)

nominal
diameter
of braiding
wire
(mm)

nominal nominal minimum approxi- approxiouter


outer
bending mate
mate
diameter diameter radius
weight
weight

conductor conductor
resistance resistance
at 20 C DC at 20 C DC

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

266
380
330
437
562
703
851
1,117
1,384

8.2
9.8
11.6
13.1
15.4
17.1
18.5
21.3
23.7

11.0
12.8
15.1
16.8
19.2
21.2
22.8
26.0
28.8

0.535
0.713
0.811
0.886
0.988
1.094
1.165
1.307
1.429

13.6
18.1
20.6
22.5
25.1
27.8
29.6
33.2
36.3

0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.40
0.40

0.697
0.874
0.980
1.055
1.173
1.287
1.358
1.520
1.650

17.7
22.2
24.9
26.8
29.8
32.7
34.5
38.6
41.9

106
133
149
161
179
196
207
232
251

443
685
874
1,062
1,310
1,596
1,848
2,369
2,856

660
1,020
1,300
1,580
1,950
2,375
2,750
3,525
4,250

0.169
0.118
0.083
0.063
0.049
0.039
0.032
0.0244
0.0195

0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
0.0641

35
50
70
95

266
380
330
437

8.2
9.8
11.6
13.1

11.0
12.8
15.1
16.8

1.067
1.228
1.437
1.587

27.1
31.2
36.5
40.3

0.32
0.40
0.40
0.40

1.260
1.402
1.657
1.815

32.0
35.6
42.1
46.1

192
214
253
277

1,270
1,720
2,301
2,822

1,890
2,560
3,425
4,200

0.169
0.118
0.083
0.063

0.554
0.386
0.272
0.206

3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240

266
380
330
437
562
703
851
1,117

8.2
9.8
11.6
13.1
15.4
17.1
18.5
21.3

11.0
12.8
15.1
16.8
19.2
21.2
22.8
26.0

1.154
1.315
1.543
1.701
1.929
2.122
2.272
2.579

29.3
33.4
39.2
43.2
49.0
53.9
57.7
65.5

0.32
0.40
0.40
0.40
0.40
0.40
0.40
0.40

1.346
1.528
1.772
1.937
2.173
2.374
2.531
2.854

34.2
38.8
45.0
49.2
55.2
60.3
64.3
72.5

205
233
270
295
331
362
386
435

1,512
2,036
2,755
3,420
4,301
5,214
6,064
7,795

2,250
3,030
4,100
5,090
6,400
7,760
9,025
11,600

0.169
0.118
0.083
0.063
0.049
0.039
0.032
0.0244

0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801

4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150

266
380
330
437
562
703

8.2
9.8
11.6
13.1
15.4
17.1

11.0
12.8
15.1
16.8
19.2
21.2

1.272
1.457
1.709
1.890
2.146
2.354

32.3
37.0
43.4
48.0
54.5
59.8

0.40
0.40
0.40
0.40
0.40
0.40

1.484
1.677
1.945
2.134
2.398
2.614

37.7
42.6
49.4
54.2
60.9
66.4

226
256
296
325
365
398

1,881
2,486
3,360
4,206
5,288
6,384

2,800
3,700
5,000
6,260
7,870
9,500

0.169
0.118
0.083
0.063
0.049
0.039

0.554
0.386
0.272
0.206
0.161
0.129

1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
2x
2x
2x
2x

193

Opmaak Control Cables 27-07-2001 15:13 Pagina 6

Power and control cables


HXXMB-FR EEP 0.6/1 kV IEC 60092-3
Class 2 conductors

Application:

Identification of the cores:

Armored fire resistant power and control cables 0.6/1 kV


with special properties for electrical installations in ships
and offshore units. Temperature Class 85 C, Flame
Retardant (IEC 60332-3 category A, A/F), Low Smoke,
Halogen Free, Low Toxicity and Fire Resistant
(IEC 60331 950 C). Suitable for application in cold climate
areas required to pass cold bend and cold impact testing
at 40 C and 35 C, respectively.

1 core
2 cores
3 cores
4 cores
5 cores and up:

Generally according to IEC 60092-3 0.6/1 kV


Conductors:

Insulation:

Assembly:
Filler:
Innersheath:
Braiding:

Sheathing:

Sheathing color:

Special cable properties:


Fire propagation:
Fire resistance:
Smoke:

Construction:

Acidity:

stranded bare annealed


copper, IEC 60228, (Class 2)
sizes 1 - 300 mm2
mica tape, and cross linked polyethylene (XLPE/HF XLPE) according to
IEC 60092-3, IEC 60092-351 and IEEE
Std 45
cores cabled together
halogen free filling compound
halogen free, flame retardant,
(SHF1, IEC 60092-359)
bronze wires according to IEEE Std
45, CDA 220, weight coverage 90%
on nominal diameter, according to
IEC 60092-3, wire diameter
0.32 - 0.40 mm
halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 Ibs/in
(6.4 N/mm)
gray (other colors are available on
request)

194

black
black, blue
black, blue, brown
black, blue, brown, green/yellow
black, numbered

Halogen content:
Toxicity index:
Cold properties:

IEC 60332-3 category A, A/F


IEC 60331 950 C
IEC 61034-1/2 , MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92

Opmaak Control Cables 27-07-2001 15:13 Pagina 7

General data for HXXMB-FR EEP 0.6/1 kV IEC 60092-3


Class 2 conductors
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 2
(n)

nominal
nominal nominal
conductor core
diameter
diameter diameter over innersheath
(mm)
(mm)
(inches)

nominal
diameter
over innersheath
(mm)

nominal
diameter
of braiding
wire
(mm)

nominal nominal minimum approxi- approxiouter


outer
bending mate
mate
diameter diameter radius
weight
weight

conductor conductor
resistance resistance
at 20 C DC at 20 C DC

(inches)

(mm)

(mm)

(lbs/M)

(/M)

1 x 1.5
1 x 2.5
1x 4
1x 6
1 x 10
1 x 16
1 x 25
1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300

7
7
7
7
7
7
7
19
19
19
19
37
37
37
61
61

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4
13.9
15.5
17.3
19.9
22.2

4.3
4.7
5.5
6.0
7.1
8.3
9.8
10.6
11.9
13.9
15.8
18.6
20.3
22.3
25.4
28.1

0.252
0.272
0.299
0.319
0.370
0.421
0.492
0.520
0.677
0.764
0.846
0.961
1.059
1.150
1.283
1.398

6.4
6.9
7.6
8.1
9.4
10.7
12.5
13.2
17.2
19.4
21.5
24.4
26.9
29.2
32.6
35.5

0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.40
0.40

0.394
0.413
0.441
0.461
0.516
0.575
0.646
0.681
0.839
0.933
1.016
1.146
1.252
1.343
1.496
1.618

10.0
10.5
11.2
11.7
13.1
14.6
16.4
17.3
21.3
23.7
25.8
29.1
31.8
34.1
38.0
41.1

50
53
56
59
79
88
98
104
128
142
155
175
191
205
228
247

111
121
144
161
212
276
363
437
645
840
1,055
1,290
1,546
1,848
2,385
2,856

165
180
215
240
315
410
540
650
960
1,250
1,570
1,920
2,300
2,750
3,550
4,250

3.7
2.26
1.41
0.94
0.56
0.35
0.222
0.160
0.118
0.082
0.059
0.047
0.038
0.0302
0.0230
0.0183

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601

2x
2x
2x
2x
2x
2x
2x
2x
2x
2x
2x

1.5
2.5
4
6
10
16
25
35
50
70
95

7
7
7
7
7
7
7
19
19
19
19

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4

4.3
4.7
5.5
6.0
7.1
8.3
9.8
10.6
11.9
13.9
15.8

0.461
0.508
0.579
0.630
0.728
0.850
0.976
1.035
1.157
1.346
1.512

11.7
12.9
14.7
16.0
18.5
21.6
24.8
26.3
29.4
34.2
38.4

0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.40
0.40
0.40

0.614
0.661
0.740
0.791
0.890
1.020
1.161
1.228
1.370
1.567
1.740

15.6
16.8
18.8
20.1
22.6
25.9
29.5
31.2
34.8
39.8
44.2

94
101
113
121
136
155
177
187
209
239
265

255
302
383
450
591
806
1,075
1,243
1,646
2,184
2,755

380
450
570
670
880
1,200
1,600
1,850
2,450
3,250
4,100

3.7
2.26
1.41
0.94
0.56
0.35
0.222
0.160
0.118
0.082
0.059

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193

3 x 1.5
3 x 2.5
3x 4
3x 6
3 x 10
3 x 16
3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240

7
7
7
7
7
7
7
19
19
19
19
37
37
37
61

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4
13.9
15.5
17.3
19.9

4.3
4.7
5.5
6.0
7.1
8.3
9.8
10.6
11.9
13.9
15.8
18.6
20.3
22.3
25.4

0.492
0.535
0.614
0.669
0.772
0.886
1.039
1.110
1.240
1.425
1.618
1.862
2.047
2.236
2.524

12.5
13.6
15.6
17.0
19.6
22.5
26.4
28.2
31.5
36.2
41.1
47.3
52.0
56.8
64.1

0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.40
0.40
0.40
0.40
0.40
0.40
0.40

0.646
0.689
0.776
0.831
0.941
1.063
1.224
1.303
1.453
1.654
1.854
2.106
2.299
2.496
2.799

16.4
17.5
19.7
21.1
23.9
27.0
31.1
33.1
36.9
42.0
47.1
53.5
58.4
63.4
71.1

98
105
118
127
143
162
187
199
221
252
283
321
350
380
427

282
329
417
497
672
874
1,210
1,478
1,949
2,587
3,360
4,133
5,006
6,048
7,728

420
490
620
740
1,000
1,300
1,800
2,200
2,900
3,850
5,000
6,150
7,450
9,000
11,500

3.7
2.26
1.41
0.94
0.56
0.35
0.222
0.160
0.118
0.082
0.059
0.047
0.038
0.0302
0.0230

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754

4 x 1.5
4 x 2.5
4x 4
4x 6
4 x 10
4 x 16
4 x 25
4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150

7
7
7
7
7
7
7
19
19
19
19
37
37

1.6
2.0
2.5
3.1
4.0
5.0
6.3
7.0
8.1
9.7
11.4
13.9
15.5

4.3
4.7
5.5
6.0
7.1
8.3
9.8
10.6
11.9
13.9
15.8
18.6
20.3

0.543
0.583
0.661
0.713
0.854
0.980
1.142
1.236
1.366
1.583
1.799
2.071
2.272

13.8
14.8
16.8
18.1
21.7
24.9
29.0
31.4
34.7
40.2
45.7
52.6
57.7

0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.40
0.40
0.40
0.40
0.40
0.40

0.697
0.744
0.823
0.874
1.024
1.165
1.335
1.449
1.587
1.819
2.043
2.323
2.531

17.7
18.9
20.9
22.2
26.0
29.6
33.9
36.8
40.3
46.2
51.9
59.0
64.3

106
113
125
133
156
178
203
221
242
277
311
354
386

323
376
470
558
806
1,075
1,478
1,881
2,385
3,192
4,166
5,107
6,182

480
560
700
830
1,200
1,600
2,200
2,800
3,550
4,750
6,200
7,600
9,200

3.7
2.26
1.41
0.94
0.56
0.35
0.222
0.160
0.118
0.082
0.059
0.047
0.038

12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124

1.5
2.5
4

7
7
7

1.6
2.0
2.5

4.3
4.7
5.5

0.602
0.650
0.736

15.3
16.5
18.7

0.32
0.32
0.32

0.764
0.811
0.906

19.4
20.6
23.0

116
124
138

376
437
571

560
650
850

3.7
2.26
1.41

12.1
7.41
4.61

24 x

1.3

3.8

1.047

26.6

0.32

1.228

31.2

187

806

1,200

5.5

18.1

6x
7x
8x
12 x
20 x
24 x
30 x
37 x

1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

7
7
7
7
7
7
7
7

1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

4.3
4.3
4.3
4.3
4.3
4.3
4.3
4.3

0.622
0.626
0.681
0.827
1.043
1.169
1.248
1.358

15.8
15.9
17.3
21.0
26.5
29.7
31.7
34.5

0.32
0.32
0.32
0.32
0.32
0.32
0.40
0.40

0.783
0.787
0.843
0.996
1.228
1.362
1.461
1.571

19.9
20.0
21.4
25.3
31.2
34.6
37.1
39.9

119
120
128
152
187
208
223
239

349
373
400
548
796
1,008
1,162
1,378

520
555
595
815
1,185
1,500
1,730
2,050

3.7
3.7
3.7
3.7
3.7
3.7
3.7
3.7

12.1
12.1
12.1
12.1
12.1
12.1
12.1
12.1

6x
7x
8x
10 x
12 x

2.5
2.5
2.5
2.5
2.5

7
7
7
7
7

2.0
2.0
2.0
2.0
2.0

4.7
4.7
4.7
4.7
4.7

0.673
0.677
0.744
0.874
0.906

17.1
17.2
18.9
22.2
195
23.0

0.32
0.32
0.32
0.32
0.32

0.835
0.839
0.913
1.043
1.083

21.2
21.3
23.2
26.5
27.5

127
128
139
159
165

403
430
497
598
672

600
640
740
890
1,000

2.26
2.26
2.26
2.26
2.26

5x
5x
5x

(kg/km)

(/km)

7.41
7.41
7.41
7.41
7.41

Opmaak Control Cables 27-07-2001 15:14 Pagina 8

Power and control cables


HXXMB-FR EEP 0.6/1 kV IEC 60092-3
Class 5 conductors

Application:

Identification of the cores:

Armored fire resistant power and control cables 0.6/1 kV


with special properties for electrical installations in ships
and offshore units. Temperature Class 85 C, Flame
Retardant (IEC 60332-3 category A, A/F), Low Smoke,
Halogen Free, Low Toxicity and Fire Resistant
(IEC 60331 950 C). Suitable for application in cold climate
areas required to pass cold bend and cold impact testing
at 40 C and 35 C, respectively.

1 core
2 cores
3 cores
4 cores

Special cable properties:


Fire propagation:
Fire resistance:
Smoke:

Construction:
Acidity:

Generally according to IEC 60092-3 0.6/1 kV


Conductors:

Insulation:

Assembly:
Filler:
Innersheath:
Braiding:

Sheathing:

Sheathing color:

flexible bare annealed


copper, IEC 60228, (Class 5)
sizes 1 - 300 mm2
mica tape, and cross linked polyethylene (XLPE/HF XLPE) according to
IEC 60092-3, IEC 60092-351 and IEEE
Std 45
cores cabled together
halogen free filling compound
halogen free, flame retardant,
(SHF1, IEC 60092-359)
bronze wires according to IEEE Std
45, CDA 220, weight coverage 90%
on nominal diameter, according to
IEC 60092-3, wire diameter
0.32 - 0.40 mm
halogen free, flame retardant (SHF1,
IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

196

black
black, blue
black, blue, brown
black, blue, brown, green/yellow

Halogen content:
Toxicity index:
Cold properties:

IEC 60332-3 category A, A/F


IEC 60331 950 C
IEC 61034-1/2 , MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92

Opmaak Control Cables 27-07-2001 15:14 Pagina 9

General data for HXXMB-FR EEP 0.6/1 kV IEC 60092-3


Class 5 conductors
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 5
(n)

nominal
nominal nominal
conductor core
diameter
diameter diameter over innersheath
(mm)
(mm)
(inches)

nominal
diameter
over innersheath
(mm)

nominal
diameter
of braiding
wire
(mm)

nominal nominal minimum approxi- approxiouter


outer
bending mate
mate
diameter diameter radius
weight
weight

conductor conductor
resistance resistance
at 20 C DC at 20 C DC

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

266
380
330
437
562
703
851
1,117
1,384

8.2
9.8
11.6
13.1
15.4
17.1
18.5
21.3
23.7

11.7
13.5
15.8
17.5
20.0
21.9
23.5
26.8
29.6

0.563
0.740
0.839
0.913
1.020
1.122
1.193
1.339
1.457

14.3
18.8
21.3
23.2
25.9
28.5
30.3
34.0
37.0

0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.40
0.40

0.724
0.902
1.008
1.083
1.205
1.315
1.386
1.551
1.677

18.4
22.9
25.6
27.5
30.6
33.4
35.2
39.4
42.6

110
137
154
165
184
200
211
236
256

454
706
907
1,075
1,337
1,629
1,868
2,396
2,856

675
1,050
1,350
1,600
1,990
2,425
2,780
3,565
4,250

0.169
0.118
0.083
0.063
0.049
0.039
0.032
0.0244
0.0195

0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
0.0641

35
50
70
95

266
380
330
437

8.2
9.8
11.6
13.1

11.7
13.5
15.8
17.5

1.134
1.303
1.496
1.646

28.8
33.1
38.0
41.8

0.32
0.40
0.40
0.40

1.327
1.516
1.717
1.874

33.7
38.5
43.6
47.6

202
231
262
286

1,361
1,831
2,385
2,940

2,025
2,725
3,550
4,375

0.169
0.118
0.083
0.063

0.554
0.386
0.272
0.206

3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240

266
380
330
437
562
703
851
1,117

8.2
9.8
11.6
13.1
15.4
17.1
18.5
21.3

11.7
13.5
15.8
17.5
20.0
21.9
23.5
26.8

1.217
1.378
1.602
1.764
2.000
2.185
2.350
2.642

30.9
35.0
40.7
44.8
50.8
55.5
59.7
67.1

0.32
0.40
0.40
0.40
0.40
0.40
0.40
0.40

1.409
1.591
1.831
2.000
2.244
2.437
2.610
2.917

35.8
40.4
46.5
50.8
57.0
61.9
66.3
74.1

215
242
279
305
342
371
398
445

1,593
2,150
2,873
3,528
4,421
5,342
6,249
7,929

2,370
3,200
4,275
5,250
6,580
7,950
9,300
11,800

0.169
0.118
0.083
0.063
0.049
0.039
0.032
0.0244

0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801

4 x 35
4 x 50
4 x 70
4 x 95
4 x 120
4 x 150

266
380
330
437
562
703

8.2
9.8
11.6
13.1
15.4
17.1

11.7
13.5
15.8
17.5
20.0
21.9

1.346
1.524
1.780
1.961
2.224
2.425

34.2
38.7
45.2
49.8
56.5
61.6

0.40
0.40
0.40
0.40
0.40
0.40

1.559
1.744
2.016
2.205
2.476
2.685

39.6
44.3
51.2
56.0
62.9
68.2

238
266
307
336
377
409

1,982
2,570
3,467
4,314
5,443
6,552

2,950
3,825
5,160
6,240
8,100
9,750

0.169
0.118
0.083
0.063
0.049
0.039

0.554
0.386
0.272
0.206
0.161
0.129

1 x 35
1 x 50
1 x 70
1 x 95
1 x 120
1 x 150
1 x 185
1 x 240
1 x 300
2x
2x
2x
2x

197

Opmaak Control Cables 27-07-2001 15:17 Pagina 18

Instrumentation and communication cables


HXXMB-FR EEP 0.6/1 kV IEC 60092-3
Overall shielded*

Application:

Identification of the groups:

Armored overall shielded fire resistant instrumentation


and communication cables 0.6/1 kV with special properties
for electrical installations in ships and offshore units.
Temperature Class 85 C, Flame Retardant (IEC 60332-3
category A, A/F), Low Smoke, Halogen Free, Low
Toxicity and Fire Resistant (IEC 60331 950 C). Suitable for
application in cold climate areas required to pass cold
bend and cold impact testing at 40 C and 35 C,
respectively.

1 pair
1 triad
1 quad

Special cable properties:


Fire propagation:
Fire resistance:
Smoke:
Acidity:

Construction:

Halogen content:

According to IEC 60092-3 with enhanced properties.


Conductors:
Insulation:

Twisting:
Overall shield:
Innersheath:
Braiding:

18
Sheathing:

Sheathing color:

stranded bare annealed


copper, IEC 60 228, sizes 1 to 2.5 mm2
mica tape, and cross linked polyethylene (XLPE/HF XLPE) according to
IEC 60092-3, IEC 60092-351 and
IEEE Std 45
cores twisted to a pair/triad/quad
tinned copper drain wire; aluminum/polyester tape; polyester tape
halogen free, flame retardant
(SHF1, IEC 60092-359)
bronze wires according to IEEE
Std 45, CDA 220, weight coverage
90% on nominal diameter according
to IEC 60092-3, wire diameter
0.32 - 0.40 mm
halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

198

black, white
black, white, red
black, white, red, green

Toxicity index:
Cold properties:

*Remark:

IEC 60332-3 category A, A/F


IEC 60331 950 C
IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92
Other constructions available on
request.

Opmaak Control Cables 27-07-2001 15:17 Pagina 19

General data for HXXMB-FR Overall shielded EEP 0.6/1 kV IEC 60092-3
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 2
(n)

nominal
nominal nominal
conductor core
diameter
diameter diameter over innersheath
(mm)
(mm)
(inches)

nominal
diameter
over innersheath
(mm)

nominal
diameter
of braiding
wire
(mm)

nominal nominal minimum approxi- approxiouter


outer
bending mate
mate
diameter diameter radius
weight
weight

conductor conductor
resistance resistance
at 20 C DC at 20 C DC

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

1x2x1
1x3x1

7
7

1.3
1.3

3.8
3.8

0.406
0.429

10.3
10.9

0.32
0.32

0.559
0.583

14.2
14.8

85
89

195
215

290
320

5.6
5.6

18.5
18.5

1 x 2 x 1.5
1 x 3 x 1.5
1 x 4 x 1.5

7
7
7

1.6
1.6
1.6

4.1
4.1
4.1

0.429
0.461
0.504

10.9
11.7
12.8

0.32
0.32
0.32

0.579
0.614
0.665

14.7
15.6
16.9

88
94
101

208
249
280

310
370
416

3.7
3.7
3.7

12.3
12.3
12.3

1 x 2 x 2.5

2.0

4.5

0.472

12.0

0.32

0.622

15.8

95

269

400

2.30

7.56

Electrical characteristics for HXXMB-FR Overall shielded EEP 0.6/1 kV IEC 60092-3
,
cross section of
the conductor
(mm2)
1
1.5
2.5

mutual capacitance
core to core (nF/M)
pair, triad & quad
20
22
25

mutual capacitance
core to core (nF/km)
pair, triad & quad
66
73
82

mutual capacitance
core to shield (nF/M)
pair, triad & quad
35
38
42

199

mutual capacitance
core to shield (nF/km)
pair, triad & quad
115
124
138

loop inductance
(mH/M)
pair & triad
0.24
0.23
0.21

loop inductance
(mH/km)
pair & triad
0.80
0.76
0.70

loop inductance
(mH/M)
quad
0.27
-

loop inductance
mH/km)
quad
0.90
-

Opmaak Control Cables 27-07-2001 15:18 Pagina 22

Instrumentation and communication cables


HXXMB EEP 0.6/1 kV IEC 60092-3
Individually shielded and isolated*

Application:

Identification of the groups:

Armored, individually shielded and isolated instrumentation and communication cables 0.6/1 kV with special
properties for electrical installations in ships and offshore
units. Temperature Class 85 C, Flame Retardant
(IEC 60332-3 category A, A/F), Low Smoke, Halogen
Free, Low Toxicity. Suitable for application in cold climate
areas required to pass cold bend and cold impact testing
at 40 C and 35 C, respectively.

1 pair
multi pairs

1 triad
multi triads

black, white
black, white
(groups sequential cores numbered
1-1, 2-2, 3-3 etc.)
black, white, red
black, white, red
(groups sequential cores numbered
1-1-1, 2-2-2, 3-3-3, etc.)

Special cable properties:


Construction:
According to IEC 60092-3 with enhanced properties.

Fire propagation:
Smoke:

Conductors:

Acidity:

Insulation:

Twisting:
Individual shield
and isolation:
Assembly:
Innersheath:
Braiding:

28

Sheathing:

Sheathing color:

stranded bare annealed


copper, IEC 60228, sizes 1 - 4 mm2
cross linked polyethylene (XLPE/
HF XLPE) according to IEC 60092-3,
IEC 60092-351 and IEEE Std 45
cores twisted to a pair/triad
tinned copper drain wire; aluminum/polyester tape; polyester tape
shielded pairs/triads cabled together
halogen free, flame retardant
(SHF1, IEC 60092-359)
bronze wires according to IEEE
Std 45, CDA 220, weight coverage
90% on nominal diameter according
to IEC 60092-3, wire diameter
0.32 - 0.40 mm
halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

200

Halogen content:
Toxicity index:
Cold properties:

*Remark:

IEC 60332-3 category A, A/F


IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92
Other constructions available on
request

Opmaak Control Cables 27-07-2001 15:18 Pagina 23

General data for HXXMB Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 2
(n)

nominal
nominal nominal
conductor core
diameter
diameter diameter over innersheath
(mm)
(mm)
(inches)

nominal
diameter
over innersheath
(mm)

nominal
diameter
of braiding
wire
(mm)

nominal nominal minimum approxi- approxiouter


outer
bending mate
mate
diameter diameter radius
weight
weight

conductor conductor
resistance resistance
at 20 C DC at 20 C DC

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

1x2x1
2x2x1
4x2x1
10 x 2 x 1
12 x 2 x 1
16 x 2 x 1

7
7
7
7
7
7

1.3
1.3
1.3
1.3
1.3
1.3

3.1
3.1
3.1
3.1
3.1
3.1

0.350
0.567
0.673
0.984
1.047
1.185

8.9
14.4
17.1
25.0
26.6
30.1

0.32
0.32
0.32
0.32
0.32
0.32

0.500
0.728
0.843
1.177
1.240
1.386

12.7
18.5
21.4
29.9
31.5
35.2

76
111
128
179
189
211

161
323
383
766
806
1,008

240
480
570
1,140
1,200
1,500

5.6
5.6
5.6
5.6
5.6
5.6

18.5
18.5
18.5
18.5
18.5
18.5

1 x 2 x 1.5
2 x 2 x 1.5
5 x 2 x 1.5
12 x 2 x 1.5

7
7
7
7

1.6
1.6
1.6
1.6

3.4
3.4
3.4
3.4

0.370
0.606
0.799
1.130

9.4
15.4
20.3
28.7

0.32
0.32
0.32
0.32

0.524
0.768
0.969
1.331

13.3
19.5
25.7
33.8

80
117
148
203

148
363
484
927

220
540
720
1,380

3.7
3.7
3.7
3.7

12.3
12.3
12.3
12.3

12 x 2 x 2.5

2.0

3.8

1.272

32.3

0.40

1.484

37.7

226

1,075

1,600

2.30

7.56

2x2x4

2.5

4.6

0.787

20.0

0.32

0.957

24.3

146

491

730

1.43

4.70

1x3x1

1.3

3.1

0.370

9.4

0.32

0.524

13.3

80

343

510

5.6

18.5

1 x 3 x 1.5
10 x 3 x 1.5
16 x 3 x 1.5

7
7
7

1.6
1.6
1.6

3.4
3.4
3.4

0.394
1.240
1.499

10.0
31.5
36.8

0.32
0.40
0.40

0.543
1.453
1.677

13.8
36.9
42.6

83
221
256

349
1,062
1,378

520
1,580
2,050

3.7
3.7
3.7

12.3
12.3
12.3

Electrical characteristics for HXXMB Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
cross section of the
conductor
(mm2)

mutual capacitance
core to core (nF/M)
pair & triad

mutual capacitance
core to core (nF/km)
pair & triad

mutual capacitance
core to shield (nF/M)
pair & triad

mutual capacitance
core to shield (nF/km)
pair & triad

loop inductance
(mH/M)
pair & triad

loop inductance
(mH/km)
pair & triad

1
1.5
2.5
4

19
21
24
25

63
70
79
82

33
37
41
43

108
121
136
142

0.22
0.21
0.20
0.19

0.72
0.68
0.64
0.62

201

Opmaak Control Cables 27-07-2001 15:18 Pagina 22

Instrumentation and communication cables


HXXMB EEP 250 V IEC 60092-3
Individually shielded and isolated*

Application:

Identification of the groups:

Armored, individually shielded and isolated instrumentation and communication cables 250 V with special
properties for electrical installations in ships and offshore
units. Temperature Class 85 C, Flame Retardant
(IEC 60332-3 category A, A/F), Low Smoke, Halogen
Free, Low Toxicity. Suitable for application in cold climate
areas required to pass cold bend and cold impact testing
at 40 C and 35 C, respectively.

1 pair
multi pairs

1 triad
multi triads

black, white
black, white
(groups sequential cores numbered
1-1, 2-2, 3-3 etc.)
black, white, red
black, white, red
(groups sequential cores numbered
1-1-1, 2-2-2, 3-3-3, etc.)

Special cable properties:


Construction:
According to IEC 60092-3 with enhanced properties.

Fire propagation:
Smoke:

Conductors:

Acidity:

Insulation:

Twisting:
Individual shield
and isolation:
Assembly:
Innersheath:
Braiding:

22

Sheathing:

Sheathing color:

stranded bare annealed


copper, IEC 60228, sizes 1 - 4 mm2
cross linked polyethylene (XLPE/
HF XLPE) according to IEC 60092-3,
IEC 60092-351 and IEEE Std 45
cores twisted to a pair/triad
tinned copper drain wire; aluminum/polyester tape; polyester tape
shielded pairs/triads cabled together
halogen free, flame retardant
(SHF1, IEC 60092-359)
bronze wires according to IEEE
Std 45, CDA 220, weight coverage
90% on nominal diameter according
to IEC 60092-3, wire diameter
0.32 - 0.40 mm
halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

202

Halogen content:
Toxicity index:
Cold properties:

*Remark:

IEC 60332-3 category A, A/F


IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
NES 713
cold bend (40 C) and cold impact
(35 C) according to CAN/CSA-C22.2
No. 0.3-Dec. 92
Other constructions available on
request

Opmaak Control Cables 27-07-2001 15:18 Pagina 23

General data for HXXMB Individually shielded and isolated EEP 250V IEC 60092-3
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 2
(n)

nominal
nominal nominal
conductor core
diameter
diameter diameter over innersheath
(mm)
(mm)
(inches)

nominal
diameter
over innersheath
(mm)

nominal
diameter
of braiding
wire
(mm)

nominal nominal minimum approxi- approxiouter


outer
bending mate
mate
diameter diameter radius
weight
weight

conductor conductor
resistance resistance
at 20 C DC at 20 C DC

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

1x2x1
2x2x1
4x2x1
10 x 2 x 1
12 x 2 x 1
16 x 2 x 1

7
7
7
7
7
7

1.3
1.3
1.3
1.3
1.3
1.3

3.1
3.1
3.1
3.1
3.1
3.1

0.350
0.567
0.673
0.984
1.047
1.185

8.9
14.4
17.1
25.0
26.6
30.1

0.32
0.32
0.32
0.32
0.32
0.32

0.500
0.728
0.843
1.177
1.240
1.386

12.7
18.5
21.4
29.9
31.5
35.2

76
111
128
179
189
211

161
323
383
766
806
1,008

240
480
570
1,140
1,200
1,500

5.6
5.6
5.6
5.6
5.6
5.6

18.5
18.5
18.5
18.5
18.5
18.5

1 x 2 x 1.5
2 x 2 x 1.5
5 x 2 x 1.5
12 x 2 x 1.5

7
7
7
7

1.6
1.6
1.6
1.6

3.4
3.4
3.4
3.4

0.370
0.606
0.799
1.130

9.4
15.4
20.3
28.7

0.32
0.32
0.32
0.32

0.524
0.768
0.969
1.331

13.3
19.5
24.6
33.8

80
117
148
203

148
363
484
927

220
540
720
1,380

3.7
3.7
3.7
3.7

12.3
12.3
12.3
12.3

12 x 2 x 2.5

2.0

3.8

1.272

32.3

0.40

1.484

37.7

226

1,075

1,600

2.30

7.56

2x2x4

2.5

4.6

0.787

20.0

0.32

0.957

24.3

146

491

730

1.43

4.70

1x3x1

1.3

3.1

0.370

9.4

0.32

0.524

13.3

80

343

510

5.6

18.5

1 x 3 x 1.5
10 x 3 x 1.5
16 x 3 x 1.5

7
7
7

1.6
1.6
1.6

3.4
3.4
3.4

0.394
1.240
1.499

10.0
31.5
36.8

0.32
0.40
0.40

0.543
1.453
1.677

13.8
36.9
42.6

83
221
256

349
1,062
1,378

520
1,580
2,050

3.7
3.7
3.7

12.3
12.3
12.3

Electrical characteristics for HXXMB Individually shielded and isolated EEP 250 V IEC 60092-3
cross section of the
conductor
(mm2)

mutual capacitance
core to core (nF/M)
pair & triad

mutual capacitance
core to core (nF/km)
pair & triad

mutual capacitance
core to shield (nF/M)
pair & triad

mutual capacitance
core to shield (nF/km)
pair & triad

loop inductance
(mH/M)
pair & triad

loop inductance
(mH/km)
pair & triad

1
1.5
2.5
4

19
21
24
25

63
70
79
82

33
37
41
43

108
121
136
142

0.22
0.21
0.20
0.19

0.72
0.68
0.64
0.62

203

Opmaak Control Cables 27-07-2001 15:18 Pagina 20

Instrumentation and communication cables


HXXMB-FR EEP 0.6/1 kV IEC 60092-3
Individually shielded and isolated*

Application:

Identification of the groups:

Armored, individually shielded and isolated fire resistant


instrumentation and communication cables 0.6/1 kV with
special properties for electrical installations in ships and
offshore units. Temperature Class 85 C, Flame Retardant
(IEC 60332-3 category A/F), Low Smoke, Halogen Free,
Low Toxicity and Fire Resistant (IEC 60331 950 C). Suitable
for application in cold climate areas required to pass cold
bend and cold impact testing at 40 C and 35 C,
respectively.

1 pair
multi pairs

1 triad
multi triads

black, white
black, white
(groups sequential numbered
1-1, 2-2, 3-3 etc.)
black, white, red
black, white, red
(groups sequential numbered
1-1-1, 2-2-2, 3-3-3 etc.)

Special cable properties:


Construction:

Fire propagation:
Fire resistance:
Smoke:

According to IEC 60092-3 with enhanced properties.


Conductors:
Insulation:

Twisting:
Individual shield
and isolation:
Assembly:
Innersheath:
Braiding:

26

Sheathing:

Sheathing color:

stranded bare annealed


copper, IEC 60228, sizes 1 to 4 mm2
mica tape, and cross linked polyethylene (XLPE/HF XLPE) according to
IEC 60092-3, IEC 60092-351 and
IEEE Std 45
cores twisted to a pair/triad/quad
tinned copper drain wire; aluminum/polyester tape; polyester tape
shielded pairs/triads/quads cabled
together
halogen free, flame retardant
(SHF1, IEC 60092-359)
bronze wires according to IEEE
Std 45, CDA 220, weight coverage
90% on nominal diameter according
to IEC 60092-3, wire diameter
0.32 - 0.40 mm
halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

204

Acidity:
Halogen content:
Toxicity index:
Cold properties:

*Remark:

IEC 60332-3 category A, A/F


IEC 60331 950 C
IEC 61034-1/2, MIL-C-24643A (par. 4.7.27) and
NES 711
IEC 60754-1/2 and MIL-C-24643A (par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A (par. 4.7.26)
NES 713
cold bend (40 C) and cold impact (35 C)
according to CAN/CSA-C22.2 No. 0.3-Dec. 92
Other constructions available on request

Opmaak Control Cables 27-07-2001 15:18 Pagina 21

General data for HXXMB-FR Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 2
(n)

nominal
nominal nominal
conductor core
diameter
diameter diameter over innersheath
(mm)
(mm)
(inches)

nominal
diameter
over innersheath
(mm)

nominal
diameter
of braiding
wire
(mm)

nominal nominal minimum approxi- approxiouter


outer
bending mate
mate
diameter diameter radius
weight
weight

conductor conductor
resistance resistance
at 20 C DC at 20 C DC

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

1x2x1
2x2x1
4x2x1
7x2x1
8x2x1
10 x 2 x 1
12 x 2 x 1
16 x 2 x 1
19 x 3 x 1

7
7
7
7
7
7
7
7
7

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

0.406
0.677
0.799
0.909
1.004
1.177
1.264
1.429
1.465

10.3
17.2
20.3
23.1
25.5
29.9
32.1
36.3
37.2

0.32
0.32
0.32
0.32
0.32
0.40
0.40
0.40
0.40

0.559
0.846
0.969
1.087
1.189
1.390
1.476
1.650
1.693

14.2
21.5
24.6
27.6
30.2
35.3
37.5
41.9
43.0

85
129
148
166
181
212
225
251
258

195
390
484
625
739
1,008
1,075
1,344
1,411

290
580
720
930
1,100
1,500
1,600
2,000
2,100

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6

18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5

1 x 2 x 1.5
2 x 2 x 1.5
4 x 2 x 1.5
5 x 2 x 1.5
8 x 2 x 1.5
12 x 2 x 1.5

7
7
7
7
7
7

1.6
1.6
1.6
1.6
1.6
1.6

4.1
4.1
4.1
4.1
4.1
4.1

0.429
0.717
0.846
0.945
1.063
1.350

10.9
18.2
21.5
24.0
27.0
34.3

0.32
0.32
0.32
0.32
0.32
0.40

0.579
0.882
1.024
1.122
1.248
1.571

14.7
22.4
26.0
28.5
31.7
39.9

88
134
156
171
190
239

208
423
551
645
796
1,243

310
630
820
960
1,185
1,850

3.7
3.7
3.7
3.7
3.7
3.7

12.3
12.3
12.3
12.3
12.3
12.3

1 x 2 x 2.5
12 x 2 x 2.5

7
7

2.0
2.0

4.5
4.5

0.472
1.480

12.0
37.6

0.32
0.40

0.622
1.709

15.8
43.4

95
260

269
1,411

400
2,100

2.30
2.30

7.56
7.56

2x2x4

2.5

5.3

0.898

22.8

0.32

1.075

27.3

164

605

900

1.43

4.70

1x3x1
4x3x1

7
7

1.3
1.3

3.8
3.8

0.429
0.909

10.9
23.1

0.32
0.32

0.583
1.087

14.8
27.6

89
166

215
591

320
880

5.6
5.6

18.5
18.5

1 x 3 x 1.5
10 x 3 x 1.5
16 x 3 x 1.5

7
7
7

1.6
1.6
1.6

4.1
4.1
4.1

0.461
1.469
1.819

11.7
37.3
46.2

0.32
0.40
0.40

0.614
1.697
2.063

15.6
43.1
52.4

94
259
314

249
1,478
1,781

370
2,200
2,650

3.7
3.7
3.7

12.3
12.3
12.3

Electrical characteristics for HXXMB-FR Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
cross section of the
conductor
(mm2)

mutual capacitance
core to core (nF/M)
pair & triad

mutual capacitance
core to core (nF/km)
pair & triad

mutual capacitance
core to shield (nF/M)
pair & triad

mutual capacitance
core to shield (nF/km)
pair & triad

loop inductance
(mH/M)
pair & triad

loop inductance
(mH/km)
pair & triad

1
1.5
2.5
4

20
22
25
26

66
73
82
84

35
38
42
43

115
124
138
141

0.24
0.23
0.21
0.21

0.80
0.76
0.70
0.68

205

Opmaak Control Cables 27-07-2001 15:18 Pagina 20

Instrumentation and communication cables


HXXMB-FR EEP 250 V IEC 60092-3
Individually shielded and isolated*

Application:

Identification of the groups:

Armored, individually shielded and isolated fire resistant


instrumentation and communication cables 250 V with
special properties for electrical installations in ships and
offshore units. Temperature Class 85 C, Flame Retardant
(IEC 60332-3 category A/F), Low Smoke, Halogen Free,
Low Toxicity and Fire Resistant (IEC 60331 950 C). Suitable
for application in cold climate areas required to pass cold
bend and cold impact testing at 40 C and 35 C,
respectively.

1 pair
multi pairs

1 triad
multi triads

1 quad

black, white
black, white
(groups sequential numbered
1-1, 2-2, 3-3 etc.)
black, white, red
black, white, red
(groups sequential numbered
1-1-1, 2-2-2, 3-3-3 etc.)
black, white, red, green

Special cable properties:


Construction:

Fire propagation:
Fire resistance:
Smoke:

According to IEC 60092-3 with enhanced properties.


Conductors:
Insulation:

Twisting:
Individual shield
and isolation:
Assembly:
Innersheath:
Braiding:

20

Sheathing:

Sheathing color:

stranded bare annealed


copper, IEC 60228, sizes 1 to 4 mm2
mica tape, and cross linked polyethylene (XLPE/HF XLPE) according to
IEC 60092-3, IEC 60092-351 and
IEEE Std 45
cores twisted to a pair/triad/quad
tinned copper drain wire; aluminum/polyester tape; polyester tape
shielded pairs/triads/quads cabled
together
halogen free, flame retardant
(SHF1, IEC 60092-359)
bronze wires according to IEEE
Std 45, CDA 220, weight coverage
90% on nominal diameter according
to IEC 60092-3, wire diameter
0.32 - 0.40 mm
halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
gray (other colors are available on
request)

206

Acidity:
Halogen content:
Toxicity index:
Cold properties:

*Remark:

IEC 60332-3 category A, A/F


IEC 60331 950 C
IEC 61034-1/2, MIL-C-24643A (par. 4.7.27) and
NES 711
IEC 60754-1/2 and MIL-C-24643A (par. 4.7.25)
IEC 60754-1/2 and MIL-C-24643A (par. 4.7.26)
NES 713
cold bend (40 C) and cold impact (35 C)
according to CAN/CSA-C22.2 No. 0.3-Dec. 92
Other constructions available on request

Opmaak Control Cables 27-07-2001 15:18 Pagina 21

General data for HXXMB-FR Individually shielded and isolated EEP 250 V IEC 60092-3
number of
cores and
nominal cross
sectional area
(n x mm2)

number of
wires in
conductor
class 2
(n)

nominal
nominal nominal
conductor core
diameter
diameter diameter over innersheath
(mm)
(mm)
(inches)

nominal
diameter
over innersheath
(mm)

nominal
diameter
of braiding
wire
(mm)

nominal nominal minimum approxi- approxiouter


outer
bending mate
mate
diameter diameter radius
weight
weight

conductor conductor
resistance resistance
at 20 C DC at 20 C DC

(inches)

(mm)

(mm)

(lbs/M)

(kg/km)

(/M)

(/km)

1x2x1
2x2x1
4x2x1
7x2x1
8x2x1
10 x 2 x 1
12 x 2 x 1
16 x 2 x 1
19 x 3 x 1

7
7
7
7
7
7
7
7
7

1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3

3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8
3.8

0.406
0.677
0.799
0.909
1.004
1.177
1.264
1.429
1.465

10.3
17.2
20.3
23.1
25.5
29.9
32.1
36.3
37.2

0.32
0.32
0.32
0.32
0.32
0.40
0.40
0.40
0.40

0.559
0.846
0.969
1.087
1.189
1.390
1.476
1.650
1.693

14.2
21.5
24.6
27.6
30.2
35.3
37.5
41.9
43.0

85
129
148
166
181
212
225
251
258

195
390
484
625
739
1,008
1,075
1,344
1,411

290
580
720
930
1,100
1,500
1,600
2,000
2,100

5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6
5.6

18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5
18.5

1 x 2 x 1.5
2 x 2 x 1.5
4 x 2 x 1.5
5 x 2 x 1.5
8 x 2 x 1.5
12 x 2 x 1.5

7
7
7
7
7
7

1.6
1.6
1.6
1.6
1.6
1.6

4.1
4.1
4.1
4.1
4.1
4.1

0.429
0.717
0.846
0.945
1.063
1.350

10.9
18.2
21.5
24.0
27.0
34.3

0.32
0.32
0.32
0.32
0.32
0.40

0.579
0.882
1.024
1.122
1.248
1.571

14.7
22.4
26.0
28.5
31.7
39.9

88
134
156
171
190
239

208
423
551
645
796
1,243

310
630
820
960
1,185
1,850

3.7
3.7
3.7
3.7
3.7
3.7

12.3
12.3
12.3
12.3
12.3
12.3

1 x 2 x 2.5
12 x 2 x 2.5

7
7

2.0
2.0

4.5
4.5

0.472
1.480

12.0
37.6

0.32
0.40

0.622
1.709

15.8
43.4

95
260

269
1,411

400
2,100

2.30
2.30

7.56
7.56

2x2x4

2.5

5.3

0.898

22.8

0.32

1.075

27.3

164

605

900

1.43

4.70

1x3x1
4x3x1

7
7

1.3
1.3

3.8
3.8

0.429
0.909

10.9
23.1

0.32
0.32

0.583
1.087

14.8
27.6

89
166

215
591

320
880

5.6
5.6

18.5
18.5

1 x 3 x 1.5
10 x 3 x 1.5
16 x 3 x 1.5

7
7
7

1.6
1.6
1.6

4.1
4.1
4.1

0.461
1.469
1.819

11.7
37.3
46.2

0.32
0.40
0.40

0.614
1.697
2.063

15.6
43.1
52.4

94
259
314

249
1,478
1,781

370
2,200
2,650

3.7
3.7
3.7

12.3
12.3
12.3

Electrical characteristics for HXXMB-FR Individually shielded and isolated EEP 250 V IEC 60092-3
cross section of the
conductor
(mm2)

mutual capacitance
core to core (nF/M)
pair & triad

mutual capacitance
core to core (nF/km)
pair & triad

mutual capacitance
core to shield (nF/M)
pair & triad

mutual capacitance
core to shield (nF/km)
pair & triad

loop inductance
(mH/M)
pair & triad

loop inductance
(mH/km)
pair & triad

1
1.5
2.5
4

20
22
25
26

66
73
82
84

35
38
42
43

115
124
138
141

0.24
0.23
0.21
0.21

0.80
0.76
0.70
0.68

207

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 1 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Fire resistant, flame retardant
halogen-free power cable. Mud
resistant

BFOU 0,6/1kV
MGT/EPR/EPR/TCWB/EVA
NEK 606 CodeP5/P12

Operating temperature
Operating Voltage

: 90C
: 0,6/1kV

Standards applied
Application
Fixed installation for power, control and lighting in both EX- and
safe areas, emergency and critical systems where requirement for
fire resistance exists. For installation in areas exposed to MUD and
drilling/cleaning fluids. Meets the MUD resistance requirement in
NEK 606.

IEC 60092-353
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60331-21
IEC 60754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour

B
F

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape

Tinned annealed copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2


(IEC 60092-359)
E.g. "meter" "r" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX FLAME IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229
DRAKA 01 = Draka Norsk Kabel
Black

www.drakaMOG.com
208

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 2 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross
Number
Conductor
section section
of
Diameter,
core,
screen,
elements
mm
mm
mm
1
16
4
5.15

Thickness
Insulation
Inner
Thickness,
covering,
mm
mm
1.0
1.1

25

6.45

1.2

1.1

50

10

9.0

1.4

1.1

70

10

10.85

1.4

1.1

95

10

12.60

1.6

1.1

1
1
1
1
1
2

120
150
185
240
300
1.5

10
10
10
16
16
4

14.20
15.90
17.70
20.15
22.60
1.6

1.6
1.8
2.0
2.2
2.4
1.0

1.2
1.2
1.2
1.2
1.2
1.1

3G

1.5

1.6

1.0

1.1

4G

1.5

1.6

1.0

1.1

1.5

1.6

1.0

1.1

1.5

1.6

1.0

1.1

1.5

1.6

1.0

1.1

1.5

1.6

1.0

1.1

12

1.5

10

1.6

1.0

1.2

19

1.5

10

1.6

1.0

27

1.5

16

1.6

37

1.5

16

5G

1.5

32
7G

Diameter
inner
covering,
mm
10 0.8
11.5
0.8

Diameter
outer
sheath,
mm
13 0.8
15.5
0.8
18.5
0.8

Weight
of Cable
Approx.
(Kg/Km)
370

Copper
content
Approx.
(kg/km)
198

530

314

870

555

1.4

20.5 1

1110

744

0.3

1.5

23 1

1420

985

0.3
0.3
0.3
0.3
0.3
0.2

1.6
1.7
1.7
1.8
1.9
1.2

1730
2100
2500
3170
3890
285

1224
1510
1837
2371
2975
80

0.3

1.3

360

125

0.3

1.3

420

156

0.3

1.3

360

125

0.3

1.3

420

156

13 0.8

0.3

1.4

480

170

0.3

1.4

560

214

0.3

1.6

23 1

830

316

1.2

14 0.8
18.5
0.8
22 1

25 1
27.5 1
29.5 1
33 1.5
36 1.5
13 0.8
14.5
0.8
15.5
0.8
14.5
0.8
15.5
0.8
16.5
0.8
18 0.8

0.3

1.7

1130

438

1.0

1.2

26.5 1

0.3

1.9

1500

574

1.6

1.0

1.4

30 1.5

0.3

1950

741

1.6

1.0

1.1

13 0.8

0.3

1.4

480

170

1.5

16

1.6

1.0

1.4

29 1

0.3

1800

668

2.5

2.0

1.0

1.1

15 0.8

0.3

1.4

26.5 1
31.5
1.5
35.5
1.5
16.5
0.8
34.5
1.5
19 0.8
14.5
0.8
15 0.8

650

276

15 0.8
16.5
0.8
18.5
0.8
20.5 1
23 1
25 1
28 1
31 1.5
10 0.8
10.5
0.8
11.5
0.8
10.5
0.8
11.5
0.8

Diameter
Braid
Wire,
mm
0.2

Thickness
Outer
Sheath,
mm
1.2

0.3

1.3

0.3

1.4

0.3

2.5

2.0

1.0

1.1

11 0.8

0.3

1.3

3G

2.5

2.0

1.0

1.1

11.5

0.3

1.3

www.drakaMOG.com
209

370

129

420

169

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 3 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Cross Cross
Number
Conductor Insulation
section section
of
Diameter, Thickness,
core,
screen,
elements
mm
mm
mm
mm

Thickness
Inner
covering,
mm

4G

2.5

2.0

1.0

1.1

2.5

2.0

1.0

1.1

8G

2.5

2.0

1.0

1.1

7
12
19

2.5
2.5
2.5

6
10
10

2.0
2.0
2.0

1.0
1.0
1.0

1.1
1.2
1.2

Diameter
inner
covering,
mm
0.8
11.5
0.8
12.5
0.8
12.5
0.8
19.5
0.8
15 0.8
20.5 1
24 1

1.1

27

2.5

16

2.0

1.0

1.4

37
5G
4G

2.5
2.5
4

25
-

2.0
2.0
2.55

1.0
1.0
1.0

1.4
1.1
1.1

5G

2.55

1.0

1.1

2.55

1.0

2.55

3G

2
3

2.5

2.0

1.0

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

Diameter
outer
sheath,
mm

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

0.3

1.3

15 0.8

420

169

480

192

480

192

16.5
0.8
16.5
0.8

0.3

1.3

0.3

1.3

0.3

1.5

23.5 1

790

332

0.3
0.3
0.3

1.4
1.6
1.8

650
990
1380

277
425
611

29.5 1

0.3

1920

844

33 1.5
14 0.8
14 0.8
15.5
0.8

0.4
0.3
0.3

2.2
1.4
1.4

2570
570
610

1200
231
263

0.3

1.4

700

299

1.1

12 0.8

0.3

1.3

450

173

1.0

1.1

13 0.8

0.3

1.3

510

210

2.55

1.0

1.1

14 0.8

0.3

1.4

610

263

2.55

1.0

1.1

13 0.8

0.3

1.3

510

210

6
6

6
6

3.15
3.15

1.0
1.0

1.1
1.1

0.3
0.3

1.4
1.4

530
620

209
280

3.15

1.0

1.1

0.3

1.4

720

334

3G

3.15

1.0

1.1

0.3

1.4

620

280

4G

3.15

1.0

1.1

0.3

1.4

720

334

5G
2
3
4
3G
4G
5G

6
10
10
10
10
10
10

10
10
10
-

3.15
4.05
4.05
4.05
4.05
4.05
4.05

1.0
1.0
1.0
1.0
1.0
1.0
1.0

1.1
1.1
1.1
1.1
1.1
1.1
1.2

0.3
0.3
0.3
0.3
0.3
0.3
0.3

1.5
1.4
1.5
1.5
1.5
1.5
1.6

880
680
800
960
800
960
1170

405
298
389
496
387
494
600

16

16

5.15

1.0

1.1

0.5

1.5

22 1

990

497

16

16

5.15

1.0

1.1

0.4

1.5

23 1

1170

654

16

16

5.15

1.0

1.2

0.4

1.6

25.5 1

1410

799

3G

16

5.15

1.0

1.1

0.3

1.5

22.5 1

1090

583

5G
4G
2
3
4
4G
5G
2
3
4
3G

16
16
25
25
25
25
25
35
35
35
35

16
16
16
16
16
16
-

5.15
5.15
6.45
6.45
6.45
6.45
6.45
7.65
7.65
7.65
7.65

1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2

1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2

13 0.8
14 0.8
15.5
0.8
14 0.8
15.5
0.8
17 0.8
15 0.8
16 0.8
18 0.8
16 0.8
18 0.8
20 1
17.5
0.8
18.5
0.8
20.5 1
18.5
0.8
23 1
20.5 1
21 1
22.5 1
25 1
25 1
27.5 1
23.5 1
25 1
28 1
25 1

19 0.8
24.5 1
28.5 1
34.5
1.5
39 1.5
18 0.8
18 0.8
19.5
0.8
15.5
0.8
16.5
0.8
18 0.8
16.5
0.8
17 0.8
18 0.8
19.5
0.8
18 0.8
19.5
0.8
21.5 1
19 0.8
20 1
22 1
20 1
22 1
24 1

0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3

1.7
1.6
1.6
1.7
1.8
1.8
1.8
1.7
1.8
1.9
1.8

27.5 1
25 1
26 1
27 1
29.5 1
29.5 1
32 1.5
28 1
30 1.5
33 1.5
30 1.5

1610
1330
1370
1600
1950
1930
2290
1630
1990
2440
1970

896
727
685
887
1116
1091
1345
818
1125
1434
1101

www.drakaMOG.com
210

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 4 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Cross Cross
Number
Conductor
section section
of
Diameter,
core,
screen,
elements
mm
mm
mm
4G
35
7.65

Thickness
Insulation
Inner
Thickness,
covering,
mm
mm
1.2
1.2

Diameter
inner
covering,
mm
28 1

Diameter
Braid
Wire,
mm
0.3

Thickness
Outer
Sheath,
mm
1.9

Diameter
outer
sheath,
mm
33 1.5
36.5
1.5
34.5
1.5

Weight
of Cable
Approx.
(Kg/Km)
2440

Copper
content
Approx.
(kg/km)
1434

5G

35

7.65

1.2

1.4

31 1.5

0.3

2980

1768

50

25

9.0

1.4

1.2

29 1

0.4

1.9

2710

1602

50

25

9.0

1.4

1.4

0.4

38 1.5

3350

2033

5G

50

9.0

1.4

1.4

0.4

2.2

42 2

4090

2508

4G

50

9.0

1.4

1.4

0.3

38 1.5

3260

1949

70

35

10.85

1.4

1.4

31 1.5

0.6

3120

1758

3
4
4G
5G
3
4
4G
5G
3

70
70
70
70
95
95
95
95
120

35
35
50
50
60

10.85
10.85
10.85
10.85
12.60
12.60
12.60
12.60
14.20

1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.6
1.6

1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.6
1.4

33 1.5
37 1.5
37 1.5
41 2
38 1.5
42.5 2
42.5 2
47 2
41 2

0.5
0.4
0.4
0.4
0.6
0.5
0.4
0.4
0.6

2
2.2
2.2
2.3
2.2
2.4
2.4
2.6
2.4

3730
4550
4460
5380
4910
6090
5860
7080
6000

2347
2926
2839
3503
3133
3975
3748
4630
3953

120

60

14.20

1.6

1.6

46 2

0.6

2.5

7430

5030

4G

120

14.20

1.6

1.6

46 2

0.4

2.5

7150

4754

4G

150

15.90

1.8

1.6

52 2.5

0.5

2.7

8810

5848

4G

185

17.70

2.0

1.8

57.5
2.5

0.5

2.9

10810

7248

32.5
1.5
36 1.5
32.5
1.5

37.5
1.5
39 1.5
43 2
43 2
47 2
44.5 2
49.5 2
49 2
54 2.5
48.5 2
53.5
2.5
53 2.5
59.5
2.5
65.5 3

Ordering information
Part number
800200
800201
800203
800204
800205
800206
800207
800208
800209
800210
800215
800216
800217
800218
800219
800220
800221
800222
800223
800224
800225
800226
800227
800228
800229
800230

Description
BFOU 0.6/1kV 1X 16/4mm P5/P12
BFOU 0.6/1kV 1X 25/6mm P5/P12
BFOU 0.6/1kV 1X 50/6mm P5/P12
BFOU 0.6/1kV 1X 70/6mm P5/P12
BFOU 0.6/1kV 1X 95/10 P5/P12
BFOU 0.6/1kV 1X 120/10 P5/P12
BFOU 0.6/1kV 1X 150/10 P5/P12
BFOU 0.6/1kV 1X 185/10 P5/P12
BFOU 0.6/1kV 1X 240/16 P5/P12
BFOU 0.6/1kV 1X 300/16 P5/P12
BFOU 0.6/1kV 2X 1.5/4 P5/P12
BFOU 0.6/1kV 3G 1.5mm P5/P12
BFOU 0.6/1kV 4G 1.5mm P5/P12
BFOU 0.6/1kV 3X 1.5/6 P5/P12
BFOU 0.6/1kV 4X 1.5/6 P5/P12
BFOU 0.6/1kV 5X 1.5/6 P5/P12
BFOU 0.6/1kV 7X 1.5/6 P5/P12
BFOU 0.6/1kV 12X 1.5/10 P5/P12
BFOU 0.6/1kV 19X 1.5/10 P5/P12
BFOU 0.6/1kV 27X 1.5/16 P5/P12
BFOU 0.6/1kV 37X 1.5/16 P5/P12
BFOU 0.6/1kV 5G 1.5mm P5/P12
BFOU 0.6/1kV 32X 1.5/16 P5/P12
BFOU 0.6/1kV 7G 2.5mm P5/P12
BFOU 0.6/1kV 2X 2.5/6 P5/P12
BFOU 0.6/1kV 3G 2.5mm P5/P12

Sheath Colour
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK

www.drakaMOG.com
211

Stock item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

EAN No. DNK


7021528002003
7021528002010
7021528002034
7021528002041
7021528002058
7021528002065
7021528002072
7021528002089
7021528002096
7021528002102
7021528002157
7021528002164
7021528002171
7021528002188
7021528002195
7021528002201
7021528002218
7021528002225
7021528002232
7021528002249
7021528002256
7021528002263
7021528002270
7021528002287
7021528002294
7021528002300

EL No.
1043605
1043608
1043609
1043610
1043611
1043612
1043613
1043615
1043620
1043619
1043640
1043660
1043705
1043707
1043712
1043719
1043727
1043621
1043639

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 5 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Part number
800232
800233
800235
800236
800237
800238
800239
800240
800241
800242
800243
800244
800245
800246
800247
800250
800251
800252
800253
800254
800255
800256
800257
800258
800259
800260
800261
800262
800263
800264
800265
800266
800267
800268
800269
800270
800271
800272
800273
800275
800276
800277
800278
800279
800280
800282
800283
800284
800285
800287
800288
800289
800290
800291
800295
800296
800297
800298
800301
800304
800306

Description
BFOU 0.6/1kV 3X 2.5/6 P5/P12
BFOU 0.6/1kV 4G 2.5mm P5/P12
BFOU 0.6/1kV 4X 2.5/6 P5/P12
BFOU 0.6/1kV 8G 2.5mm P5/P12
BFOU 0.6/1kV 7X 2.5/6 P5/P12
BFOU 0.6/1kV 12X 2.5/10 P5/P12
BFOU 0.6/1kV 19X 2.5/10 P5/P12
BFOU 0.6/1kV 27X 2.5/16 P5/P12
BFOU 0.6/1kV 37X 2.5/25 P5/P12
BFOU 0.6/1kV 5G 2.5mm P5/P12
BFOU 0.6/1kV 4G 4mm P5/P12
BFOU 0.6/1kV 5G 4mm P5/P12
BFOU 0.6/1kV 2X 4/6mm P5/P12
BFOU 0.6/1kV 3X 4/6mm P5/P12
BFOU 0.6/1kV 4X 4/6mm P5/P12
BFOU 0.6/1kV 3G 4mm P5/P12
BFOU 0.6/1kV 2X 6/6mm P5/P12
BFOU 0.6/1kV 3X 6/6mm P5/P12
BFOU 0.6/1kV 4X 6/6mm P5/P12
BFOU 0.6/1kV 3G 6mm P5/P12
BFOU 0.6/1kV 4G 6mm P5/P12
BFOU 0.6/1kV 5G 6mm P5/P12
BFOU 0.6/1kV 2X 10/10 P5/P12
BFOU 0.6/1kV 3X 10/10 P5/P12
BFOU 0.6/1kV 4X 10/10 P5/P12
BFOU 0.6/1kV 3G 10mm P5/P12
BFOU 0.6/1kV 4G 10mm P5/P12
BFOU 0.6/1kV 5G 10mm P5/P12
BFOU 0.6/1kV 2X 16/16 P5/P12
BFOU 0.6/1kV 3X 16/16 P5/P12
BFOU 0.6/1kV 4X 16/16 P5/P12
BFOU 0.6/1kV 3G 16mm P5/P12
BFOU 0.6/1kV 5G 16mm P5/P12
BFOU 0.6/1kV 4G 16mm P5/P12
BFOU 0.6/1kV 2X 25/16 P5/P12
BFOU 0.6/1kV 3X 25/16 P5/P12
BFOU 0.6/1kV 4X 25/16 P5/P12
BFOU 0.6/1kV 4G 25mm P5/P12
BFOU 0.6/1kV 5G 25mm P5/P12
BFOU 0.6/1kV 2X 35/16 P5/P12
BFOU 0.6/1kV 3X 35/16 P5/P12
BFOU 0.6/1kV 4X 35/16 P5/P12
BFOU 0.6/1kV 3G 35mm P5/P12
BFOU 0.6/1kV 4G 35mm P5/P12
BFOU 0.6/1kV 5G 35mm P5/P12
BFOU 0.6/1kV 3X 50/25 P5/P12
BFOU 0.6/1kV 4X 50/25 P5/P12
BFOU 0.6/1kV 5G 50mm P5/P12
BFOU 0.6/1kV 4G 50mm P5/P12
BFOU 0.6/1kV 2X 70/35 P5/P12
BFOU 0.6/1kV 3X 70/35 P5/P12
BFOU 0.6/1kV 4X 70/35 P5/P12
BFOU 0.6/1kV 4G 70mm P5/P12
BFOU 0.6/1kV 5G 70mm P5/P12
BFOU 0.6/1kV 3X 95/50 P5/P12
BFOU 0.6/1kV 4X 95/50 P5/P12
BFOU 0.6/1kV 4G 95mm P5/P12
BFOU 0.6/1kV 5G 95mm P5/P12
BFOU 0.6/1kV 3X 120/60 P5/P12
BFOU 0.6/1kV 4X 120/60 P5/P12
BFOU 0.6/1kV 4G 120mm P5/P12

Sheath Colour
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK

www.drakaMOG.com
212

Stock item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-

EAN No. DNK


7021528002324
7021528002331
7021528002355
7021528002362
7021528002379
7021528002386
7021528002393
7021528002409
7021528002416
7021528002423
7021528002430
7021528002447
7021528002454
7021528002461
7021528002478
7021528002508
7021528002515
7021528002522
7021528002539
7021528002546
7021528002553
7021528002560
7021528002577
7021528002584
7021528002591
7021528002607
7021528002614
7021528002621
7021528002638
7021528002645
7021528002652
7021528002669
7021528002676
7021528002683
7021528002690
7021528002706
7021528002713
7021528002720
7021528002737
7021528002751
7021528002768
7021528002775
7021528002782
7021528002799
7021528002805
7021528002829
7021528002836
7021528002843
7021528002850
7021528002874
7021528002881
7021528002898
7021528002904
7021528002911
7021528002959
7021528002966
7021528002973
7021528002980
7021528003017
7021528003048
7021528003062

EL No.
1043641
1043659
1043661
1043757
1043762
1043769
1043777
1043787
1043755
1043622
1043642
1043662
1043623
1043643
1043663
1043624
1043644
1043664
1043625
1043645
1043665
1043626
1043646
1043666
1043627
1043647
1043667
1043648
1043668
1043629
1043649
1043669
1043650
1043670
1043651
-

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 6 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Part number
Description
800307
BFOU 0.6/1kV 4G 150mm P5/P12
800310
BFOU 0.6/1kV 4G 185mm P5/P12

Sheath Colour
BLACK
BLACK

Stock item
-

EAN No. DNK


7021528003079
7021528003109

EL No.
-

Electrical values power cables


Number
of
elements

1
1
1
1
1
1
1
1
1
1
2
3G
4G
3
4
5
7
12
19
27
37
5G
32
7G
2
3G
3
4G
4
8G
7
12
19
27
37
5G
4G
5G
2
3
4
3G
2
3
4
3G
4G
5G
2
3
4

Cross
section
core,
mm
16
25
50
70
95
120
150
185
240
300
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
6
6
6
6
6
6
10
10
10

Cross
section
screen,
mm
4
6
10
10
10
10
10
10
16
16
4
6
6
6
6
10
10
16
16
16
6
6
6
6
10
10
16
25
6
6
6
6
6
6
10
10
10

Conductor
type 2

STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC

Max.
conductor
resistance at
20C,
Ohm/km
1.16
0.734
0.391
0.27
0.195
0.154
0.126
0.1
0.0762
0.0607
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.7
4.7
4.7
4.7
4.7
4.7
3.11
3.11
3.11
3.11
3.11
3.11
1.84
1.84
1.84

Max.
conductor
resistance at
90C,
Ohm/km
1.48
0.936
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
5.99
5.99
5.99
5.99
5.99
5.99
3.97
3.97
3.97
3.97
3.97
3.97
2.35
2.35
2.35

Reactance
at 50Hz,
Ohm/km

0.118
0.114
0.105
0.1
0.097
0.095
0.094
0.092
0.09
0.088
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.115
0.107
0.107
0.107
0.107
0.107
0.107
0.107
0.107
0.107
0.107
0.107
0.107
0.107
0.1
0.1
0.100
0.100
0.1
0.1
0.094
0.094
0.094
0.094
0.094
0.094
0.088
0.088
0.088

www.drakaMOG.com
213

Reactance
at 60Hz,
Ohm/km

0.142
0.136
0.126
0.12
0.116
0.114
0.112
0.11
0.108
0.106
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.138
0.129
0.129
0.129
0.129
0.129
0.129
0.129
0.129
0.129
0.129
0.129
0.129
0.129
0.120
0.120
0.120
0.120
0.120
0.120
0.112
0.112
0.112
0.112
0.112
0.112
0.105
0.105
0.105

Current
rating IEC
60092-352
Table B.4,
Ampere
96
127
196
242
293
339
389
444
522
601
20
20
16
16
16
13.5
12
10
8.5
7.5
7
16
7
16.5
26
26
21
21
21
15.5
15.5
13
11
10
9
21
28
28
34
28
28
34
44
36
36
44
36
36
61
50
50

Short
circuit
rating 1
second,
Ampere
2240
3500
7000
9800
13300
16800
21000
25900
33600
42000
210
210
210
210
210
210
210
210
210
210
210
210
210
350
350
350
350
350
350
350
350
350
350
350
350
350
560
560
560
560
560
560
840
840
840
840
840
840
1400
1400
1400

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 7 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Number
of
elements

3G
4G
5G
2
3
4
3G
5G
4G
2
3
4
4G
5G
2
3
4
3G
4G
5G
3
4
5G
4G
2
3
4
4G
5G
3
4
4G
5G
3
4
4G
4G
4G

Cross
section
core,
mm
10
10
10
16
16
16
16
16
16
25
25
25
25
25
35
35
35
35
35
35
50
50
50
50
70
70
70
70
70
95
95
95
95
120
120
120
150
185

Cross
section
screen,
mm
16
16
16
16
16
16
16
16
16
25
25
35
35
35
50
50
60
60
-

Conductor
type 2

STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC

Max.
conductor
resistance at
20C,
Ohm/km
1.84
1.84
1.84
1.16
1.16
1.16
1.16
1.16
1.16
0.734
0.734
0.734
0.734
0.734
0.529
0.529
0.529
0.529
0.529
0.529
0.391
0.391
0.391
0.391
0.27
0.27
0.27
0.27
0.27
0.195
0.195
0.195
0.195
0.154
0.154
0.154
0.126
0.1

Max.
conductor
resistance at
90C,
Ohm/km
2.35
2.35
2.35
1.48
1.48
1.48
1.48
1.48
1.48
0.936
0.936
0.936
0.936
0.936
0.675
0.675
0.675
0.675
0.675
0.675
0.499
0.499
0.499
0.499
0.344
0.344
0.344
0.344
0.344
0.249
0.249
0.249
0.249
0.196
0.196
0.196
0.161
0.128

Reactance
at 50Hz,
Ohm/km

0.088
0.088
0.088
0.082
0.082
0.082
0.082
0.082
0.082
0.081
0.081
0.081
0.081
0.081
0.078
0.078
0.078
0.078
0.078
0.078
0.078
0.078
0.078
0.078
0.075
0.077
0.077
0.075
0.075
0.075
0.075
0.075
0.075
0.073
0.073
0.073
0.073
0.073

Reactance
at 60Hz,
Ohm/km

0.105
0.105
0.105
0.099
0.099
0.099
0.099
0.099
0.099
0.098
0.098
0.098
0.098
0.098
0.094
0.094
0.094
0.094
0.094
0.094
0.093
0.093
0.093
0.093
0.092
0.092
0.092
0.092
0.092
0.090
0.090
0.090
0.090
0.088
0.088
0.088
0.088
0.088

Current
rating IEC
60092-352
Table B.4,
Ampere
61
50
50
80
67
67
80
67
67
108
89
89
89
89
133
110
110
133
110
110
137
137
137
137
206
169
169
169
169
205
205
205
205
237
237
237
272
311

Short
circuit
rating 1
second,
Ampere
1400
1400
1400
2240
2240
2240
2240
2240
2240
3500
3500
3500
3500
3500
4900
4900
4900
4900
4900
4900
7000
7000
7000
7000
9800
9800
9800
9800
9800
13300
13300
13300
13300
16800
16800
16800
21000
25900

Ambient temperature correction factors


Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius
during Installation

Minimum Bending Radius Fixed


Installed

Maximum Tensile Load


During Installation

Minimum Installation
Temperature

8xD

6xD

50 N /mm

-20C

www.drakaMOG.com
214

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 8 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Fire resistant, flame retardant
halogen-free power cable. Mud
resistant. Single core cable.

BFOU 0,6/1kV
MGT/EPR/EPR/TCWB/EVA
NEK 606 CodeP5/P12

Operating temperature
Operating Voltage

: 90C
: 0,6/1kV

Standards applied
Application

IEC 60092-353/60502-1
IEC 60228 class 2
Fixed installation for power, control and lighting in both EX- and IEC 60092-351
safe areas, emergency and critical systems where requirement IEC 60092-359
for fire resistance exists. For installation in areas exposed to
IEC 60332-1
MUD and drilling/cleaning fluids. Meets the MUD resistance
IEC 60332-3-22
requirement in NEK 606.
IEC 60331-21
IEC 60754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour

B
F

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape

Tinned annealed copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2


(IEC 60092-359)
E.g. "meter" "r" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX FLAME IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229
DRAKA 01 = Draka Norsk Kabel
Black

www.drakaMOG.com
215

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 9 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Core identification power cables
Single core Black
Two cores - Blue Brown
Three cores - Brown - Black Grey
Four cores - Blue - Brown - Black Grey
Five cores - Blue - Brown - Black - Grey Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue Brown
Three cores + earth (4G) - Yellow/green - Brown - Black Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross
Number
Conductor
section section
of
Diameter,
core,
screen,
elements
mm
mm
mm
1
400
25
26.00
1
630
25
32.80

Thickness
Insulation
Inner
Thickness,
covering,
mm
mm
2.4
1.4
2.8
1.4

Diameter
inner
covering,
mm
35 1.5
42 2

Diameter
Braid
Wire,
mm
0.4
0.4

Thickness
Outer
Sheath,
mm
2.1
2.3

Diameter
outer
sheath,
mm
41 2
48.5 2

Weight
of Cable
Approx.
(Kg/Km)
5100
7660

Copper
content
Approx.
(kg/km)
3940
6167

Ordering information
Part number
800211
800213

Description
BFOU 0.6/1kV 1X 400/25 P5/P12
BFOU 0.6/1kV 1X 630/25 P5/P12

Sheath Colour
BLACK
BLACK

Stock item
-

EAN No. DNK


7021528002119
7021528002133

EL No.
-

Electrical values power cables


Number
of
elements

Cross
section
core,
mm

Cross
section
screen,
mm

Conductor
type 2

Max.
Max.
conductor
conductor
resistance at resistance at
20C,
90C,
Ohm/km
Ohm/km

Reactance
at 50Hz,
Ohm/km

Reactance
at 60Hz,
Ohm/km

400

25

STCC

0.0475

0.0606

0.088

0.105

630

25

STCC

0.0286

0.0606

0.084

0.101

Current
Short
rating IEC
circuit
60092-352
rating 1
Table B.4,
second,
Ampere
Ampere
690 dc / 670
56000
ac
890dc / 780
88200
ac

Ambient temperature correction factors


Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
216

Minimum Installation
Temperature
-20C

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 10 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Fire resistant, flame retardant
halogen-free power cable. Mud
resistant. Double braided.

BFOU 0,6/1kV
MGT/EPR/EPR/TCWB/EVA
NEK 606 CodeP5/P12

Operating temperature
Operating Voltage

: 90C
: 0,6/1kV

Standards applied
Application
Fixed installation for power, control and lighting in both EX- and
safe areas, emergency and critical systems where requirement for
fire resistance exists. For installation in areas exposed to MUD and
drilling/cleaning fluids. Meets the MUD resistance requirement in
NEK 606.

IEC 60092-353
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60331-21
IEC 60754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour

B
F

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape + rubberized Polyamide tape

Two layers of tinned copper wire braid (double braid)


PET tape + rubberized Polyamide tape

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2


(IEC 60092-359)
E.g. "meter" "r" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX FLAME IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229
DRAKA 01 = Draka Norsk Kabel
Black

www.drakaMOG.com
217

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 11 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross
Number
Conductor Insulation
section section
of
Diameter, Thickness,
core,
screen,
elements
mm
mm
mm
mm

Thickness
Inner
covering,
mm

Diameter
inner
covering,
mm

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

150

70

15.90

1.8

1.4

46 2

0.4

2.6

150

70

15.90

1.8

1.6

52 2.5

0.5

2.8

240

120

19.1

2.2

2.0

56.0 2.0 0.7

3.0

185

95

17.7

2.0

1.8

185

95

17.70

2.0

1.6

57.5
2.5
51.5
2.5

Diameter
outer
sheath,
mm
54.5
2.5
61 3
65.0
3.0

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

7390

4870

9380

6352

11950

8059

0.4

2.9

683

11640

7750

0.5

2.8

61 3

9370

6291

Ordering information
Part number
800302
800309
800314
800391
800392

Description
BFOU 0.6/1kV 3X 150/70 P5/P12
BFOU 0.6/1kV 4X 150/70 P5/P12
BFOU 0.6/1kV 3X 240/120 P5/P12
BFOU 0.6/1kV 4X 185/95 P5/P12
BFOU 0.6/1kV 3X 185/95 P5/P12

Sheath Colour
BLACK
BLACK
BLACK
BLACK
BLACK

Stock item
Yes
-

EAN No. DNK


7021528003024
7021528003093
7021528003147
7021528003918
7021528003925

EL No.
1043652
-

Electrical values power cables


Number
of
elements

3
4
3
4
3

Cross
section
core,
mm
150
150
240
185
185

Cross
section
screen,
mm
70
70
120
95
95

Conductor
type

KGTFR
KGTFR
KGTFR
KGTFR
KGTFR

Max.
conductor
resistance at
20C,
Ohm/km
0.126
0.126
0.0762
0.1
0.1

Max.
conductor
resistance at
90C,
Ohm/km
0.161
0.161
0.0972
0.128
0.128

Reactance
at 50Hz,
Ohm/km

0.073
0.073
0.074
0.073
0.073

www.drakaMOG.com
218

Reactance
at 60Hz,
Ohm/km

0.088
0.088
0.089
0.088
0.088

Current
rating IEC
60092-352
Table B.4,
Ampere
272
272
365
311
311

Short
circuit
rating 1
second,
Ampere
21000
21000
33600
25900
25900

BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 12 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Ambient temperature correction factors
Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
219

Minimum Installation
Temperature
-20C

BFOU(C) 250V(3).doc
04/06/2008 10:57:00
Page 1 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable


Fire resistant, flame retardant halogenfree instrumentation cable. Mud resistant

BFOU(c) 250V
MGT/EPR/EPR/TCWB/EVA
NEK 606 CodeS4/S8

Operating temperature
Operating Voltage

: 90C
: 250V

Standards applied
IEC 60092-376 (2003-05) - Design
IEC 60228 class 2
- Conductor
IEC
60092-351
- Insulation
Fixed installation for instrumentation, communication, control and
IEC
60092-359
- Sheath
alarm systems in both EX- and safe areas, emergency and critical
IEC
60332-1
- Flame Retardant
systems where requirement for fire resistance exists. Meets the
IEC
60332-3-22
- Flame Retardant
mud resistant requirements in NEK 606.
IEC 60331-21, -31
- Fire Resistant
IEC 600754-1,2
- Halogen Free
IEC 61034-1,2
- Low Smoke
Application

Construction
Code
Letter
Conductor
Insulation

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


B

Pair / Triple /
Quad twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour

Mica-tape + EP-rubber, IEC 60092-351 (EPR)


Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Flame retardant and halogen-free thermoplastic compound
PET tape

Tinned annealed copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-359)
Eg. "meter" "year" DRAKA 01 BFOU(c) 250V S4/S8 4 PAIR 0,75 mm2 FLEX FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229
DRAKA 01 = Draka Norsk Kabel
Grey or Blue

www.drakaMOG.com
220

BFOU(C) 250V(3).doc
04/06/2008 10:57:00
Page 2 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable


Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm

Thickness
Inner
covering,
mm

0.75

1.1

0.6

1.1

0.75

1.1

0.6

1.1

0.75

1.1

0.6

1.1

0.75

1.1

0.6

1.1

0.75

1.1

0.6

1.1

0.75

1.1

0.6

1.1

12

0.75

1.1

0.6

1.3

12

0.75

1.1

0.6

1.3

16
16
19

2
2
2

0.75
0.75
0.75

1.1
1.1
1.1

0.6
0.6
0.6

1.4
1.4
1.4

Diameter
inner
covering,
mm
10.5
0.8
10.5
0.8
12.5
0.8
12.5
0.8
16.5
0.8
16.5
0.8
19.5
0.8
19.5
0.8
21 1
21 1
22 1

24

0.75

1.1

0.6

1.8

24

0.75

1.1

0.6

0.75

1.1

0.75

4
4

3
3

0.75
0.75

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

0.3

1.3

0.3

1.3

0.3

1.4

0.3

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

340

114

340

114

16 0.8

450

156

1.4

16 0.8

450

156

0.3

1.5

20.5 1

680

240

0.3

1.5

20.5 1

680

240

0.3

1.6

23.5 1

920

333

0.3

1.6

23.5 1

920

333

0.3
0.3
0.3

1.7
1.7
1.8

1090
1090
1240

384
384
447

26.5 1

0.3

1590

536

1.8

26.5 1

0.3

1590

536

0.6

1.1

12 0.8

0.3

1.3

400

143

1.1

0.6

1.1

12 0.8

0.3

1.3

400

143

1.1
1.1

0.6
0.6

1.1
1.1

0.3
0.3

1.4
1.4

550
550

198
198

0.75

1.1

0.6

1.1

0.3

1.6

23 1

870

309

0.75

1.1

0.6

1.1

0.3

1.6

23 1

870

309

12
12
16
16

3
3
3
3

0.75
0.75
0.75
0.75

1.1
1.1
1.1
1.1

0.6
0.6
0.6
0.6

1.3
1.3
1.4
1.4

14 0.8
14 0.8
18.5
0.8
18.5
0.8
22 1
22 1
24 1
24 1

25.5 1
25.5 1
27 1
31.5
1.5
31.5
1.5
15.5
0.8
15.5
0.8
18 0.8
18 0.8

0.3
0.3
0.3
0.3

1.8
1.8
1.9
1.9

1160
1160
1440
1440

411
411
513
513

24

0.75

1.1

0.6

1.8

30 1.5

0.4

2.1

2180

823

1.5

1.6

0.7

1.1

13 0.8

0.3

1.4

440

162

1.5

1.6

0.7

1.1

13 0.8

0.3

1.4

440

162

4
4
8
8
12
12
16

2
2
2
2
2
2
2

1.5
1.5
1.5
1.5
1.5
1.5
1.5

1.6
1.6
1.6
1.6
1.6
1.6
1.6

0.7
0.7
0.7
0.7
0.7
0.7
0.7

1.1
1.1
1.1
1.1
1.3
1.3
1.4

15 0.8
15 0.8
20 1
20 1
23.5 1
23.5 1
26 1

0.3
0.3
0.3
0.3
0.3
0.3
0.3

1.4
1.4
1.7
1.7
1.8
1.8
1.9

26.5 1
26.5 1
29 1
29 1
35.5
1.5
16.5
0.8
16.5
0.8
19 0.8
19 0.8
24.5 1
24.5 1
28.5 1
28.5 1
30.5

590
590
980
980
1300
1300
1600

235
235
404
404
541
541
678

www.drakaMOG.com
221

Diameter
outer
sheath,
mm
14.5
0.8
14.5
0.8

BFOU(C) 250V(3).doc
04/06/2008 10:57:00
Page 3 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable


Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm

Thickness
Inner
covering,
mm

Diameter
inner
covering,
mm

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

0.3

1.4

1.1
1.1
1.1
1.1
1.3

14.5
0.8
14.5
0.8
17 0.8
17 0.8
22.5 1
22.5 1
27 1

0.3
0.3
0.3
0.3
0.3

1.5
1.5
1.8
1.8
1.9

0.7

1.6

30 1.5

0.4

2.1

1.6

0.7

1.6

30 1.5

0.4

2.1

1.6
2

0.7
0.7

2
1.1

0.4
0.3

2.4
1.4

2.5

0.7

1.1

0.3

1.5

20.5 1

730

325

2
2
2
3

2.5
2.5
2.5
2.5

2
2
2
2

0.7
0.7
0.7
0.7

1.1
1.6
2
1.1

37 1.5
14 0.8
16.5
0.8
22 1
29 1
36 1.5
25 1

Diameter
outer
sheath,
mm
1.5
30.5
1.5
38.5
1.5
38.5
1.5
18.5
0.8
18.5
0.8
21 1
21 1
27 1
27 1
32 1.5
35.5
1.5
35.5
1.5
43.5 2
18 0.8

16

1.5

1.6

0.7

1.4

26 1

0.3

1.9

24

1.5

1.6

0.7

1.8

32 1.5

0.4

2.2

24

1.5

1.6

0.7

1.8

32 1.5

0.4

2.2

1.5

1.6

0.7

1.1

0.3

1.4

1.5

1.6

0.7

1.1

4
4
8
8
12

3
3
3
3
3

1.5
1.5
1.5
1.5
1.5

1.6
1.6
1.6
1.6
1.6

0.7
0.7
0.7
0.7
0.7

16

1.5

1.6

16

1.5

24
2

3
2

1.5
2.5

8
16
24
8
16

0.3
0.4
0.4
0.3

1.8
2.1
2.4
1.9

1210
2200
3220
1600

551
1053
1509
762

2.5

0.7

1.6

33 1.5

0.4

2.3

27 1
35 1.5
42.5 2
30 1.5
39.5
1.5

2940

1471

Electrical values instrumentation cables


Capacitance, approx.
Type
(nF/km)
Unshielded pair 0,75 mm
100

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

1600

678

2430

1031

2430

1031

530

208

530

208

740
740
1240
1240
1690

308
308
518
518
736

2300

1035

2300

1035

3280
520

1418
217

Inductance, approx,
(mH/km)
0,67

Resistance at 20C, max.


(Ohm/km)
26,3

L/R ratio,
(microH/Ohm)
12,7

Unshielded triple 0,75 mm

100

0,67

26,3

12,7

Unshielded pair 1,5 mm

110

0,63

12,2

26,6

Unshielded triple 1,5 mm

110

0,63

12,2

26,6

Unshielded pair 2,5 mm

125

0,59

7,56

39,0

Unshielded triple 2,5 mm

125

0,59

7,56

39,0

Ordering information
Part number
893806
893807
893818
893819
893830
893831
893836
893837
893842
893843

Description
BFOU(C) 2PAIR 0.75mm S4/S8
BFOU(C) 2PAIR 0.75mm S4/S8
BFOU(C) 4PAIR 0.75mm S4/S8
BFOU(C) 4PAIR 0.75mm S4/S8
BFOU(C) 8PAIR 0.75mm S4/S8
BFOU(C) 8PAIR 0.75mm S4/S8
BFOU(C) 12PAIR 0.75mm S4/S8
BFOU(C) 12PAIR 0.75mm S4/S8
BFOU(C) 16PAIR 0.75mm S4/S8
BFOU(C) 16PAIR 0.75mm S4/S8

Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE

www.drakaMOG.com
222

Stock item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

EAN No. DNK


7021528938067
7021528938074
7021528938180
7021528938197
7021528938302
7021528938319
7021528938364
7021528938371
7021528938425
7021528938432

EL No.
1043821
1043822
1043823
1043824
1043828
1043829
1043830
1043831
1043833
1043834

BFOU(C) 250V(3).doc
04/06/2008 10:57:00
Page 4 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable


Part number
893845
893848
893849
893866
893867
893878
893879
893890
893891
893896
893897
893902
893903
893908
894006
894007
894018
894019
894030
894031
894036
894037
894042
894043
894048
894049
894066
894067
894078
894079
894090
894091
894096
894102
894103
894108
894206
894218
894230
894242
894248
894290
894302

Description
BFOU(C) 19PAIR 0.75mm S4/S8
BFOU(C) 24PAIR 0.75mm S4/S8
BFOU(C) 24PAIR 0.75mm S4/S8
BFOU(C) 2TRIP 0.75mm S4/S8
BFOU(C) 2TRIP 0.75mm S4/S8
BFOU(C) 4TRIP 0.75mm S4/S8
BFOU(C) 4TRIP 0.75mm S4/S8
BFOU(C) 8TRIP 0.75mm S4/S8
BFOU(C) 8TRIP 0.75mm S4/S8
BFOU(C) 12TRIP 0.75mm S4/S8
BFOU(C) 12TRIP 0.75mm S4/S8
BFOU(C) 16TRIP 0.75mm S4/S8
BFOU(C) 16TRIP 0.75mm S4/S8
BFOU(C) 24TRIP 0.75mm S4/S8
BFOU(C) 2PAIR 1.5mm S4/S8
BFOU(C) 2PAIR 1.5mm S4/S8
BFOU(C) 4PAIR 1.5mm S4/S8
BFOU(C) 4PAIR 1.5mm S4/S8
BFOU(C) 8PAIR 1.5mm S4/S8
BFOU(C) 8PAIR 1.5mm S4/S8
BFOU(C) 12PAIR 1.5mm S4/S8
BFOU(C) 12PAIR 1.5mm S4/S8
BFOU(C) 16PAIR 1.5mm S4/S8
BFOU(C) 16PAIR 1.5mm S4/S8
BFOU(C) 24PAIR 1.5mm S4/S8
BFOU(C) 24PAIR 1.5mm S4/S8
BFOU(C) 2TRIP 1.5mm S4/S8
BFOU(C) 2TRIP 1.5mm S4/S8
BFOU(C) 4TRIP 1.5mm S4/S8
BFOU(C) 4TRIP 1.5mm S4/S8
BFOU(C) 8TRIP 1.5mm S4/S8
BFOU(C) 8TRIP 1.5mm S4/S8
BFOU(C) 12TRIP 1.5mm S4/S8
BFOU(C) 16TRIP 1.5mm S4/S8
BFOU(C) 16TRIP 1.5mm S4/S8
BFOU(C) 24TRIP 1.5mm S4/S8
BFOU(C) 2PAIR 2.5mm S4/S8
BFOU(C) 4PAIR 2.5mm S4/S8
BFOU(C) 8PAIR 2.5mm S4/S8
BFOU(C) 16PAIR 2.5mm S4/S8
BFOU(C) 24PAIR 2.5mm S4/S8
BFOU(C) 8TRIP 2.5mm S4/S8
BFOU(C) 16TRIP 2.5mm S4/S8

Sheath Colour
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY

Stock item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-

EAN No. DNK


7021528938456
7021528938487
7021528938494
7021528938661
7021528938678
7021528938784
7021528938791
7021528938906
7021528938913
7021528938968
7021528938975
7021528939026
7021528939033
7021528939088
7021528940060
7021528940077
7021528940183
7021528940190
7021528940305
7021528940312
7021528940367
7021528940374
7021528940428
7021528940435
7021528940480
7021528940497
7021528940664
7021528940671
7021528940787
7021528940794
7021528940909
7021528940916
7021528940961
7021528941029
7021528941036
7021528941081
7021528942064
7021528942187
7021528942309
7021528942422
7021528942484
7021528942903
7021528943023

EL No.
1043836
1043837
1043921
1043922
1043924
1043925
1043928
1043929
1043930
1043931
1043933
1043934
1043936
1043862
1043861
1043863
1043864
1043868
1043869
1043870
1043871
1043873
1043874
1043876
1043877
1043971
1043972
1043973
1043974
1043977
1043978
1043979
1043981
1043982
1043987
-

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
223

Minimum Installation
Temperature
-20C

BFOU(I) 250V(3).doc
04/06/2008 10:39:00
Page 1 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable


Fire resistant, flame retardant halogen-free
instrumentation cable. Mud resistant

BFOU(i) 250V
MGT/EPR/EPR/TCWB/EVA
NEK 606 CodeS3/S7

Operating temperature
Operating Voltage

: 90C
: 250V

Standards applied
IEC 60092-376 (2003-05)
IEC 60228 class 2
Fixed installation for instrumentation, communication, control IEC 60092-351
IEC 60092-359
and alarm systems in both EX- and safe areas, emergency
IEC 60332-1
and critical systems where requirement for fire resistance
IEC 60332-3-22
exists. Meets the mud resistant requirements in NEK 606.
IEC 60331-21, -31
IEC 600754-1,2
IEC 61034-1,2
Application

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation

Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped
with a PETP tape.
Flame retardant and halogen-free thermoplastic compound
PET tape

Tinned annealed copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-359)
Eg. "meter" "year" DRAKA 01 BFOU(i) 250V S3/S7 16 PAIR 0,75 mm2 FLEX FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229
DRAKA 01 = Draka Norsk Kabel
Grey or Blue

www.drakaMOG.com
224

BFOU(I) 250V(3).doc
04/06/2008 10:39:00
Page 2 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable


Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm

Thickness
Inner
covering,
mm

Diameter
inner
covering,
mm

0.75

1.1

0.6

1.1

7.5 0.5 0.2

1.1

0.75

1.1

0.6

1.1

7.5 0.5 0.2

1.1

0.75

1.1

0.6

1.1

11 0.8

0.3

1.3

0.75

1.1

0.6

1.1

11 0.8

0.3

1.3

0.75

1.1

0.6

1.1

0.3

1.4

0.75

1.1

0.6

1.1

8
8
12
12
16
16
19
19

2
2
2
2
2
2
2
2

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75

1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6

1.1
1.1
1.3
1.3
1.4
1.4
1.4
1.4

12.5
0.8
12.5
0.8
17 0.8
17 0.8
20.5 1
20.5 1
23 1
23 1
24 1
24 1

24

0.75

1.1

0.6

1.8

29 1

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

0.3

1.4

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3

1.6
1.6
1.7
1.7
1.8
1.8
1.9
1.9

0.4

2.1

24

0.75

1.1

0.6

1.8

29 1

0.4

2.1

1
1

3
3

0.75
0.75

1.1
1.1

0.6
0.6

1.1
1.1

8 0.5
8 0.5

0.2
0.2

1.1
1.1

0.75

1.1

0.6

1.1

12 0.8

0.3

1.4

0.75

1.1

0.6

1.1

12 0.8

0.3

1.4

0.75

1.1

0.6

1.1

14 0.8

0.3

1.4

0.75

1.1

0.6

1.1

14 0.8

0.3

1.4

0.75

1.1

0.6

1.1

0.3

1.7

0.75

1.1

0.6

1.1

12
12
16

3
3
3

0.75
0.75
0.75

1.1
1.1
1.1

0.6
0.6
0.6

19

0.75

1.1

24

0.75

24

1
1
2
2

2
2
2
2

Diameter
outer
sheath,
mm
10.5
0.8
10.5
0.8
14.5
0.8
14.5
0.8
16.5
0.8
16.5
0.8
21.5 1
21.5 1
25 1
25 1
27.5 1
27.5 1
28.5 1
28.5 1
34.5
1.5
34.5
1.5
11 0.8
11 0.8
15.5
0.8
15.5
0.8
17.5
0.8
17.5
0.8

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

200

55

200

55

360

135

360

135

490

186

490

186

780
780
1050
1050
1310
1310
1460
1460

288
288
381
381
475
475
526
526

2000

723

2000

723

220
220

68
68

410

147

410

147

570

212

570

212

23 1

970

364

0.3

1.7

23 1

970

364

1.3
1.3
1.4

18.5
0.8
18.5
0.8
22.5 1
22.5 1
25.5 1

0.3
0.3
0.3

1.8
1.8
1.9

1300
1300
1630

484
484
604

0.6

1.6

26.5 1

0.3

1850

675

1.1

0.6

1.8

0.4

2.2

2460

924

0.75

1.1

0.6

1.8

0.4

2.2

2460

924

1.5
1.5
1.5
1.5

1.6
1.6
1.6
1.6

0.7
0.7
0.7
0.7

1.1
1.1
1.1
1.1

0.2
0.2
0.3
0.3

1.1
1.1
1.4
1.4

27 1
27 1
30 1.5
31.5
1.5
37.5
1.5
37.5
1.5
12 0.8
12 0.8
17 0.8
17 0.8

255
255
470
470

79
79
186
186

31.5
1.5
31.5
1.5
9 0.5
9 0.5
13 0.8
13 0.8

www.drakaMOG.com
225

BFOU(I) 250V(3).doc
04/06/2008 10:39:00
Page 3 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable


Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm

Thickness
Inner
covering,
mm

1.5

1.6

0.7

1.1

1.5

1.6

0.7

1.1

8
8
12
12
16
16

2
2
2
2
2
2

1.5
1.5
1.5
1.5
1.5
1.5

1.6
1.6
1.6
1.6
1.6
1.6

0.7
0.7
0.7
0.7
0.7
0.7

1.1
1.1
1.3
1.3
1.6
1.6

Diameter
inner
covering,
mm
15.5
0.8
15.5
0.8
21 1
21 1
25 1
25 1
29 1
29 1

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

0.3

1.5

0.3

1.5

0.3
0.3
0.3
0.3
0.3
0.3

1.7
1.7
1.9
1.9
2
2

19

1.5

1.6

0.7

1.6

30 1.5

0.4

2.1

24

1.5

1.6

0.7

1.8

0.4

2.3

24

1.5

1.6

0.7

1.8

0.4

2.3

1.5

1.6

0.7

1.1

9.5 0.5 0.2

1.2

1.5

1.6

0.7

1.1

9.5 0.5 0.2

1.2

35.5
1.5
35.5
1.5

1.5

1.6

0.7

1.1

1.5

1.6

0.7

1.1

4
4
8
8

3
3
3
3

1.5
1.5
1.5
1.5

1.6
1.6
1.6
1.6

0.7
0.7
0.7
0.7

1.1
1.1
1.1
1.1

14.5
0.8
14.5
0.8
17 0.8
17 0.8
22.5 1
22.5 1

12

1.5

1.6

0.7

1.5

12

1.5

1.6

0.7

1.5

16

1.5

1.6

0.7

1.6

16

1.5

1.6

0.7

1.6

24

1.5

1.6

0.7

24

1.5

1.6

0.7

1
1

2
2

2.5
2.5

2
2

0.7
0.7

1.1
1.1

2.5

0.7

1.1

4
8
16

2
2
2

2.5
2.5
2.5

2
2
2

0.7
0.7
0.7

1.1
1.1
1.6

2.5

0.7

1.1

2.5

0.7

1.3

12

2.5

0.7

1.5

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

660

271

660

271

1080
1080
1490
1490
1920
1920

451
451
613
613
776
776

2290

1009

42 2

2900

1226

42 2

2970

1226

285

93

285

93

550

214

12.5
0.8
12.5
0.8
18.5
0.8
18.5
0.8
21 1
21 1
27 1
27 1
33.5
1.5
33.5
1.5
37.5
1.5
37.5
1.5

560

214

810
810
1360
1360

344
344
589
589

1920

810

1920

810

2600

1180

2600

1180

0.3

1.5

0.3

1.5

0.3
0.3
0.3
0.3

1.6
1.6
1.8
1.8

28.5 1

0.3

28.5 1

0.3

0.4

2.2

0.4

2.2

0.4

2.5

46.5 2

3720

1611

0.4

2.5

46.5 2

3720

1611

0.2
0.2

1.2
1.2

13 0.8
13 0.8
18.5
0.8
21.5 1
28 1
38 1.5
13.5
0.8
30.5
1.5
37.5
1.5

300
300

99
99

31.5
1.5
31.5
1.5
39.5
1.5
39.5
1.5
9.5 0.5
9.5 0.5
14.5
0.8
17 0.8
23.5 1
32 1.5
10.5
0.8

0.3

1.5

0.3
0.3
0.4

1.6
1.8
2.2

0.2

1.2

25.5 1

0.3

31.5
1.5

0.4

2.2

www.drakaMOG.com
226

Diameter
outer
sheath,
mm
19.5
0.8
19.5
0.8
25.5 1
25.5 1
30 1.5
30 1.5
34 1.5
34 1.5
35.5
1.5

550

225

820
1370
2590

367
633
1221

350

129

1790

844

2610

1284

BFOU(I) 250V(3).doc
04/06/2008 10:39:00
Page 4 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable


Electrical values instrumentation cables
Capacitance, approx.
Type
(nF/km)
Shielded pair 0,75 mm
110
Shielded triple 0,75 mm
110
Shielded pair 1,5 mm
125
Shielded triple 1,5 mm
125
Shielded pair 2,5 mm
145
Shielded triple 2,5 mm
145

Inductance, approx,
(mH/km)
0,67
0,67
0,63
0,63
0,59
0,59

Resistance at 20C, max.


(Ohm/km)
26,3
26,3
12,2
12,2
7,56
7,56

L/R ratio,
(microH/Ohm)
12,7
12,7
26,6
26,6
39,0
39,0

Ordering information
Part number
893200
893201
893206
893207
893218
893219
893230
893231
893236
893237
893242
893243
893245
893246
893248
893249
893260
893261
893266
893267
893278
893279
893290
893291
893296
893297
893302
893305
893308
893309
893400
893401
893406
893407
893418
893419
893430
893431
893436
893437
893442
893443
893445
893448
893449
893460

Description
BFOU(I) 1PAIR 0.75mm S3/S7
BFOU(I) 1PAIR 0.75mm S3/S7
BFOU(I) 2PAIR 0.75mm S3/S7
BFOU(I) 2PAIR 0.75mm S3/S7
BFOU(I) 4PAIR 0.75mm S3/S7
BFOU(I) 4PAIR 0.75mm S3/S7
BFOU(I) 8PAIR 0.75mm S3/S7
BFOU(I) 8PAIR 0.75mm S3/S7
BFOU(I) 12PAIR 0.75mm S3/S7
BFOU(I) 12PAIR 0.75mm S3/S7
BFOU(I) 16PAIR 0.75mm S3/S7
BFOU(I) 16PAIR 0.75mm S3/S7
BFOU(I) 19PAIR 0.75mm S3/S7
BFOU(I) 19PAIR 0.75mm S3/S7
BFOU(I) 24PAIR 0.75mm S3/S7
BFOU(I) 24PAIR 0.75mm S3/S7
BFOU(I) 1TRIP 0.75mm S3/S7
BFOU(I) 1TRIP 0.75mm S3/S7
BFOU(I) 2TRIP 0.75mm S3/S7
BFOU(I) 2TRIP 0.75mm S3/S7
BFOU(I) 4TRIP 0.75mm S3/S7
BFOU(I) 4TRIP 0.75mm S3/S7
BFOU(I) 8TRIP 0.75mm S3/S7
BFOU(I) 8TRIP 0.75mm S3/S7
BFOU(I) 12TRIP 0.75mm S3/S7
BFOU(I) 12TRIP 0.75mm S3/S7
BFOU(I) 16TRIP 0.75mm S3/S7
BFOU(I) 19TRIP 0.75mm S3/S7
BFOU(I) 24TRIP 0.75mm S3/S7
BFOU(I) 24TRIP 0.75mm S3/S7
BFOU(I) 1PAIR 1.5mm S3/S7
BFOU(I) 1PAIR 1.5mm S3/S7
BFOU(I) 2PAIR 1.5mm S3/S7
BFOU(I) 2PAIR 1.5mm S3/S7
BFOU(I) 4PAIR 1.5mm S3/S7
BFOU(I) 4PAIR 1.5mm S3/S7
BFOU(I) 8PAIR 1.5mm S3/S7
BFOU(I) 8PAIR 1.5mm S3/S7
BFOU(I) 12PAIR 1.5mm S3/S7
BFOU(I) 12PAIR 1.5mm S3/S7
BFOU(I) 16PAIR 1.5mm S3/S7
BFOU(I) 16PAIR 1.5mm S3/S7
BFOU(I) 19PAIR 1.5mm S3/S7
BFOU(I) 24PAIR 1.5mm S3/S7
BFOU(I) 24PAIR 1.5mm S3/S7
BFOU(I) 1TRIP 1.5mm S3/S7

Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY

www.drakaMOG.com
227

Stock item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

EAN No. DNK


7021528932003
7021528932010
7021528932065
7021528932072
7021528932188
7021528932195
7021528932300
7021528932317
7021528932362
7021528932379
7021528932423
7021528932430
7021528932454
7021528932461
7021528932485
7021528932492
7021528932607
7021528932614
7021528932669
7021528932676
7021528932782
7021528932799
7021528932904
7021528932911
7021528932966
7021528932973
7021528933024
7021528933055
7021528933086
7021528933093
7021528934007
7021528934014
7021528934069
7021528934076
7021528934182
7021528934199
7021528934304
7021528934311
7021528934366
7021528934373
7021528934427
7021528934434
7021528934458
7021528934489
7021528934496
7021528934601

EL No.
1043820
1043819
1044020
1044019
1044021
1044022
1044028
1044029
1044030
1044031
1044033
1044034
1044036
1044037
1043920
1043919
1044121
1044122
1044123
1044124
1044128
1044129
1044130
1044131
1044132
1044138
1044139
1043860
1043859
1044060
1044061
1044063
1044064
1044068
1044069
1044070
1044071
1044073
1044074
1044076
1044170

BFOU(I) 250V(3).doc
04/06/2008 10:39:00
Page 5 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable


Part number
893461
893466
893467
893478
893479
893490
893491
893496
893497
893502
893503
893508
893509
893600
893601
893606
893618
893630
893642
893660
893690
893696

Description
BFOU(I) 1TRIP 1.5mm S3/S7
BFOU(I) 2TRIP 1.5mm S3/S7
BFOU(I) 2TRIP 1.5mm S3/S7
BFOU(I) 4TRIP 1.5mm S3/S7
BFOU(I) 4TRIP 1.5mm S3/S7
BFOU(I) 8TRIP 1.5mm S3/S7
BFOU(I) 8TRIP 1.5mm S3/S7
BFOU(I) 12TRIP 1.5mm S3/S7
BFOU(I) 12TRIP 1.5mm S3/S7
BFOU(I) 16TRIP 1.5mm S3/S7
BFOU(I) 16TRIP 1.5mm S3/S7
BFOU(I) 24TRIP 1.5mm S3/S7
BFOU(I) 24TRIP 1.5mm S3/S7
BFOU(I) 1PAIR 2.5mm S3/S7
BFOU(I) 1PAIR 2.5mm S3/S7
BFOU(I) 2PAIR 2.5mm S3/S7
BFOU(I) 4PAIR 2.5mm S3/S7
BFOU(I) 8PAIR 2.5mm S3/S7
BFOU(I) 16PAIR 2.5mm S3/S7
BFOU(I) 1TRIP 2.5mm S3/S7
BFOU(I) 8TRIP 2.5mm S3/S7
BFOU(I) 12TRIP 2.5mm S3/S7

Sheath Colour
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
GREY
GREY

Stock item
Yes
Yes
-

EAN No. DNK


7021528934618
7021528934663
7021528934670
7021528934786
7021528934793
7021528934908
7021528934915
7021528934960
7021528934977
7021528935028
7021528935035
7021528935080
7021528935097
7021528936001
7021528936018
7021528936063
7021528936186
7021528936308
7021528936421
7021528936605
7021528936902
7021528936964

EL No.
1044169
1044171
1044173
1044174
1044177
1044178
1044179
1044180
1044181
1044182
1044193
1044194
1044140
-

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
228

Minimum Installation
Temperature
-20C

BFOU-HCF(c)-250V-HF_2006.doc
30.06.2006 08:52
Page 1 of 2

BFOU-HCF(c) 250V S16 / 1100C / 30 minutes


HydroCarbon Fire resistant, flame retardant
halogen-free instrumentation cable.

BFOU-HCF(c) 250V
5 4
2 3

MGT/EPR/EPR/TCWB/EVA/HCF/SHF1
1

NEK 606 Code S16

1100C / 2000F / 200 kW/m

Operating temperature
Operating Voltage

: 90C
: 250V

Standards applied

Application
Fixed installation for instrumentation, communication,
control and alarm systems in both EX- and safe areas,
emergency and critical systems where requirement for
hydrocarbon fire resistance is vital.

IEC 60092-376 (2003-05)


Draka Norsk Kabel
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60331-21
UL 1709 / ASTM E1529
IEC 600754-1,2
IEC 61034-1,2

- Design
- HCF protection
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- HC Fire resistance
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation

Tinned stranded circular copper, IEC 60228 class 2


B

Pair / Triple /
Quad twisting
Inner covering
Tape over
bedding
Armour/screen
Tape over
armour/screen
Outer sheath
HCF protection
Tape
Overall sheath

Mica-tape + EP-rubber, IEC 60092-351 (EPR)


Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Flame retardant and halogen-free thermoplastic compound
PET tape

Tinned copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-359)
Extruded heatblock compound
Lapped glassfibre tape
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-359)

-HCF

www.drakaMOG.com
229

BFOU-HCF(c)-250V-HF_2006.doc
30.06.2006 08:52
Page 2 of 2

BFOU-HCF(c) 250V S16 / 1100C / 30 minutes


Code
Letter
Eg. "meter" "r" DRAKA NORSK KABEL BFOU-HCF(c) 250V S16 4 PAIR 1,5 mm2
HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22
Grey

Marking text
Outer sheath
colour

Core identification instrumentation cables


Black - Light Blue
Pair
Triple
Black - Light Blue - Brown
Range and dimensions
Draka
Norsk Kabel
part no.

Type
[mm2]

Diameter
over bedding
[mm]

Thickness of
armour
wires
[mm]

Diameter
sheath

Diameter
overall HCFprotection

[mm]

Weight
of cable
approx.
[kg/km]

(mm)

886562

2 pair 1,5
4 pair 1,5
8 pair 1,5
12 pair 1,5

13,00,8
15,00,8
20,51,0
23,51,0

0,3
0,3
0,3
0,3

16,50,8
19,00,8
25,01,0
28,51,0

44,52,0
46,52,0
53,02,5
57,02,5

Electrical values instrumentation cables


TYPE
[mm2]
Multi pair 1,5

Capacitance
approx.
[nF/km]

Inductance
approx.
[mH/km]

Resist. 20C
[Max.ohm/km]

110

0,63

12,2

Installation recommendations
TYPE
[mm2]

Overall
Diameter
[mm]

2 pair 1,5
4 pair 1,5
8 pair 1,5
12 pair 1,5

44,52,0
46,52,0
53,02,5
57,02,5

Minimum bending radius


During
Fixed
Installation
Installed
[mm]
20 x D
12 x D
890
930
1060
1140

Maximum
pulling tension
[N]

534
558
636
684

Minimum installation temperature: - 10 C

www.drakaMOG.com
230

300
600
1200
1800

2400
2650
3570
4160

BFOU-HCF(i)-250V-HF_2006.doc
30.06.2006 08:46
Page 1 of 2

BFOU-HCF(i) 250V S15 / 1100C / 30 minutes


HydroCarbon Fire resistant, flame retardant
halogen-free instrumentation cable.

BFOU-HCF(i) 250V
5 4
2 3

MGT/EPR/EPR/TCWB/EVA/HCF/SHF1
1

NEK 606 Code S15

1100C / 2000F / 200 kW/m

Operating temperature
Operating Voltage

: 90C
: 250V

Standards applied

Application
Fixed installation for instrumentation, communication,
control and alarm systems in both EX- and safe areas,
emergency and critical systems where requirement for
hydrocarbon fire resistance is vital.

IEC 60092-376 (2003-05)


Draka Norsk Kabel
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60331-21
UL 1709 / ASTM E1529
IEC 600754-1,2
IEC 61034-1,2

- Design
- HCF protection
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- HC Fire resistance
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation

Tinned stranded circular copper, IEC 60228 class 2


B

Pair / Triple /
Quad twisting
Inner covering
Tape over
bedding
Armour/screen
Tape over
armour/screen
Outer sheath
HCF protection
Tape

Mica-tape + EP-rubber, IEC 60092-351 (EPR)


Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Flame retardant and halogen-free thermoplastic compound
PET tape

Tinned copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-359)
Extruded heatblock compound
Lapped glassfibre tape

-HCF

www.drakaMOG.com
231

BFOU-HCF(i)-250V-HF_2006.doc
30.06.2006 08:46
Page 2 of 2

BFOU-HCF(i) 250V S15 / 1100C / 30 minutes


Code
Letter
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-359)
Eg. "meter" "r" DRAKA NORSK KABEL BFOU-HCF(i) 250V S15 4 PAIR 1,5 mm2
HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22
Grey

Overall sheath
Marking text
Outer sheath
colour

Core identification instrumentation cables


Black - Light Blue
Pair
Triple
Black - Light Blue - Brown
Range and dimensions
Draka
Norsk Kabel
part no.

Type
[mm2]

Diameter
over bedding
[mm]

Thickness of
armour
wires
[mm]

Diameter
sheath

Diameter
overall HCFprotection

[mm]

Weight
of cable
approx.
[kg/km]

(mm)
886563

1 pair 1,5
2 pair 1,5
4 pair 1,5
8 pair 1,5
12 pair 1,5

9,00,5
13,00,8
15,50,8
21.01,0
25,01,0

0,2
0,3
0,3
0,3
0,3

12,00,8
17,00,8
19,50,8
25,51,0
30.01,5

39,51,5
44,52,0
47,52,0
54,52,5
63,03.0

Electrical values instrumentation cables


TYPE
[mm2]
single pair 1,5

Capacitance
approx.
[nF/km]

Inductance
approx.
[mH/km]

Resist. 20C
[Max.ohm/km]

125

0,63

12,2

Installation recommendations
TYPE
[mm2]

Overall
Diameter
[mm]

1 pair 1,5
2 pair 1,5
4 pair 1,5
8 pair 1,5
12 pair 1,5

39,51,5
44,52,0
47,52,0
54,52,5
63,03.0

Minimum bending radius


During
Fixed
Installation
Installed
[mm]
20 x D
12 x D
790
890
950
1090
1260

Maximum
pulling tension
[N]

474
534
570
654
756

Minimum installation temperature: - 10 C

www.drakaMOG.com
232

150
300
600
1200
1800

1880
2450
2830
3690
5200

BFOU-HCF-1kv-HF_2006_rev2.doc
30.06.2006 08:54
Page 1 of 5

BFOU-HCF 0,6/1kV P34 / 1100C / 30-60 minutes


HydroCarbon Fire resistant, flame retardant
halogen-free power cable.

BFOU-HCF 0,6/1kV
MGT/EPR/EPR/TCWB/EVA/HCF/SHF1
NEK 606 Code P34

1100C / 2000F / 200 kW/m

Operating temperature
Operating Voltage

: 90C
: 0,6/1kV

Standards applied

Application
Fixed installation for power, control and lightning in both
EX- and safe areas, emergency and critical systems
where requirement for fire resistance is vital.

IEC 60092-353
Draka Norsk Kabel
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60331-21
UL 1709 / ASTM E1529
IEC 600754-1,2
IEC 61034-1,2

- Design
- HCF protection
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- HC Fire resistance
- Halogen Free
- Low Smoke

Construction
Code Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over bedding
Armour/screen
Tape over
armour/screen
Outer sheath
HCF protection
Tape
Overall sheath
Marking text
Outer sheath
colour

B
F
O

U
-HCF

Tinned stranded circular copper, IEC 60228 class 2


Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoplastic compound
PET tape
Tinned copper wire braid
PET tape
Flame retardant, halogen-free and mud resistant thermoset compound,
SHF2 (IEC 60092-359)
Extruded heatblock compound
Lapped glassfibre tape
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092359)
Eg. "meter" "r" DRAKA NORSK KABEL BFOU-HCF 0,6/1kV P34 12 x
2,5/10 mm2 HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22
Black

www.drakaMOG.com
233

BFOU-HCF-1kv-HF_2006_rev2.doc
30.06.2006 08:54
Page 2 of 5

BFOU-HCF 0,6/1kV P34 / 1100C / 30-60 minutes


Core identification power cables
Single core
Grey (Offwhite)
Two cores
Grey (Offwhite) - Black
Three cores
Grey (Offwhite) - Black - Red
Four cores
Grey (Offwhite) - Black - Red - Blue
Five cores
Grey (Offwhite) - Black - Red - Blue - Black
Above five cores
Black numbers on white base
Separate earth core
Yellow/green
G / x in cable describtion G = one of the core are yellow/green - x = no yellow/green core
Range and dimensions
Draka
Norsk Kabel
part no.

Type
[mm2]

Diameter
over bedding
[mm]

Thickness of
armour
wires
[mm]

Diameter
sheath

Diameter
overall HCFprotection

[mm]

Weight
of cable
approx.
[kg/km]

(mm)

1x 50/6
1x 70/6
1x 95/10
1x 120/10
1x 150/10
1x 185/10
1x 240/16
1x 300/16

15,00,8
16,50,8
18,50,8
20,51,0
23,01,0
25,01,0
28,01,0
30,51,5

0,20
0,30
0,30
0,30
0,30
0,30
0,30
0,30

18,50,8
20,51,0
23,01,0
25,01,0
27,01,0
29,51,0
32,51,5
35,51,5

45,52,5
47,52,5
50,53,0
52,53,0
54,53,0
57,53,0
66,03,5
68,03,5

2900
3300
3800
4260
4750
5380
7050
8000

2x 1,5/4

10,00,8

0,20

13,00,8

40,52,5

1890

3x 1,5/4
3x 2,5/6
3x 4/6
3x 6/6
3x 16/16
3x 35/16
3x 70/35
3x 120/60
3x 150/70

10,50,8
11,50,8
13,00,8
14,00,8
18,50,8
25,01,0
33,01,5
41,02,0
46,02,0

0,20
0,30
0,30
0,30
0,40
0,30
0,50
0,60
0,40 *

14,00,8
15,00,8
16,50,8
18,00,8
23,01,0
29,51,0
39,01,5
48,02,0
54,52,5

42.02,5
42,52,5
43,02,5
45,02,5
50,03,0
57,53,0
72,04,0
81,54,5
88,54,5

2140
2200
2400
2600
3500
4840
8150
11300
13300

12.5 0.8
15.5 0.8
20.5 1.0

0.30
0.30
0.40

16.5 0.8
19.5 0.8

886546

4x 2,5/6
4x 6/6
4x 16/16

25.5 1.0

44,02,5
47,52,5
53,53,0

2300
2870
3830

885139

7x 1,5/6
12x 1,5/10

14,00,8
18,50,8

0,30
0,30

17,50,8
22,51,0

44,52,5
50,03,0

2550
3140

886549

886375

886338
885499
885882
885138

886547

www.drakaMOG.com
234

BFOU-HCF-1kv-HF_2006_rev2.doc
30.06.2006 08:54
Page 3 of 5

BFOU-HCF 0,6/1kV P34 / 1100C / 30-60 minutes


Draka
Norsk Kabel
part no.

Type
[mm2]

Diameter
over bedding
[mm]

Thickness of
armour
wires
[mm]

Diameter
sheath

19,00,8
24,51,0

885124
886036

7x 2,5/6
12x 2,5/10

15,00,8
20,51,0

0,30
0,30

886548

27x 1,5/16

26.51.0

0.30

Diameter
overall HCFprotection

Weight
of cable
approx.
[kg/km]

[mm]

31.01.5

(mm)
46,02,5
52,03,0

2760
3500

64,53,5

5070

* This cable has a double braid (two layers of wires)

ELECTRICAL DATA
No. of cores
x cross
section

Conductor resistance
DC
[/km]
at 20 C
at 90 C

Reactance
[/km]
at 50 / 60
Hz

1 X 50/6
1 X 70/6
1 X 95/10
1 X 120/10
1 X 150/10
1 X 185/10
1 X 240/16
1 X 300/16

0,391
0,270
0,195
0,154
0,126
0,100
0,0762
0,0607

0,4986
0,344
0,2486
0,1964
0,161
0,128
0,0972
0,0774

0,161/0,193
0,152/0,182
0,146/0,176
0,141/0,170
0,137/0,164
0,133/0,160
0,133/0,159
0,128/0,154

2x 1,5/4

12,2

15,56

3x 1,5/4
3x 2,5/6
3x 4/6
3x 6/6
3x 16/16
3x 35/16
3x 70/35
3x 120/60
3x 150/70

12,2
7,56
4,70
3,11
1,16
0,529
0,270
0,154
0,126

4x 2,5/6
4x 6/6
4x 16/16

Impedance
[/km] at 90
C
At 50 / 60 Hz

0,524/0,535
0,376/0,390
0,289/0,305
0,242/0,260
0,211/0,223
0,185/0,205
0,165/0,187
0,150/0,173

Continous
current
rating
at 45 C

Short circuit
[Ampere]
1 sec

0,3 sec

196
242
293
339
389
444
522
601

7000
9800
13300
16800
21000
25900
3360
42000

12780
17892
24282
30672
38340
47286
61344
76681

0,115/0,138 15,556/15,567

20

210

383

15,56
9,64
5,99
3,97
1,46
0,675
0,344
0,196
0,161

0,115/0,138
0,107/0,129
0,100/0,120
0,094/0,112
0082/0,099
0,078/0,094
0,077/0,092
0,073/0,088
0,073/0,088

16
21
28
36
67
110
169
237
272

210
350
560
840
2240
4900
9800
16800
21000

383
639
1022
1534
4089
8946
17892
30672
38340

7,56
3,11
1,16

9,64
3,97
1,46

0,107/0,129 9,640/9,641
0,094/0,112 3,967/3,9672
0082/0,099 1,481/1,482

21
36
67

350
840
2240

639
1534
4089

7x 1,5/6
12x 1,5/10

12,2
12,2

15,56
15,56

0,115/0,138 15,556/15,567
0,115/0,138 15,556/15,567

12
10

210
210

383
383

7x 2,5/6

7,56

9,64

0,107/0,129 9,640/9,641

15,5

350

639

15,556/15,567
9,640/9,641
5,993/5,994
3,967/3,9672
1,481/1,482
0,679/0,681
0,352/0,356
0,209/0,215
0,177/0,183

www.drakaMOG.com
235

BFOU-HCF-1kv-HF_2006_rev2.doc
30.06.2006 08:54
Page 4 of 5

BFOU-HCF 0,6/1kV P34 / 1100C / 30-60 minutes


No. of cores
x cross
section

Conductor resistance
DC
[/km]
at 20 C
at 90 C

Reactance
[/km]

Impedance
[/km] at 90
C
At 50 / 60 Hz

12x 2,5/10

7,56

9,64

at 50 / 60
Hz
0,107/0,129 9,640/9,641

27x 1,5/16

12,2

15,56

0,115/0,138 15,556/15,567

Continous
current
rating
at 45 C

Minimum bending radius


During
Fixed
Installation
Installed
[mm]
20 x D
12 x D

639

7,5

210

383

[mm2]

1x 50/6
1x 70/6
1x 95/10
1x 120/10
1x 150/10
1x 185/10
1x 240/16
1x 300/16

45,52,5
47,52,5
50,53,0
52,53,0
54,53,0
57,53,0
66,03,5
68,03,5

910
950
1010
1050
1090
1150
1320
1360

546
570
606
630
654
690
792
816

2500
3500
4750
6000
7500
9250
12000
15000

2x 1,5/4

40,52,5

810

486

150

3x 1,5/4
3x 2,5/6
3x 4/6
3x 6/6
3x 16/16
3x 35/16
3x 70/35
3x 120/60
3x 150/70

42,02,5
42,52,5
43,02,5
45,02,5
50,03,0
57,53,0
72,04,0
81,54,5
88,54,5

840
850
860
900
1000
1150
1440
1630
1770

504
510
516
540
600
690
864
978
1062

225
375
600
900
2400
5250
10500
18000
20000

4x 2,5/6
4x 6/6
4x 16/16

44,02,5
47,52,5
53,53,0

880
950
1070

528
570
642

500
1200
3200

7x 1,5/6
12 x 1,5/10

44,52,5
50,03,0

890
1000

536
600

525
900

7x 2,5/6
12x 2,5/10

46,02,5
52,03,0

920
1040

552
624

875
1500

236

0,3 sec

350

Overall
Diameter
[mm]

Maximum
pulling tension
[N]

www.drakaMOG.com

1 sec

13

INSTALLATION DATA
TYPE

Short circuit
[Ampere]

BFOU-HCF-1kv-HF_2006_rev2.doc
30.06.2006 08:54
Page 5 of 5

BFOU-HCF 0,6/1kV P34 / 1100C / 30-60 minutes


TYPE
[mm2]

Overall
Diameter
[mm]

27x 1,5/16

64,53,5

Minimum bending radius


During
Fixed
Installation
Installed
[mm]
1290
774

Maximum
pulling tension
[N]

Minimum installation temperature: - 10 C

www.drakaMOG.com
237

2025

BU 1kV(3).doc
29.12.2006 10:42
Page 1 of 4

BU 0,6/1kV P17, Power cable, Unarmoured


Fire resistant, flame retardant halogenfree power cable. Mud resistant

BU 0,6/1kV
MGT/EPR/EVA
NEK 606 CodeP17

Operating temperature
Operating Voltage

: 90C
: 0,6/1kV

Standards applied
Application
Fixed installation for power, control and lighting in safe areas,
emergency and critical systems where requirement for fire
resistance exists. For installation in areas exposed to MUD and
drilling/cleaning fluids. Single core cables are double-insulated
battery cables.

IEC 60092-353
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60331-21
IEC 60754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


B

Mica-tape + EP-rubber, IEC 60092-351 (EPR)


Cores laid up in concentric layers

Inner covering

No inner covering. (Additional tapes may be applied)

Armour/screen

No armour.

Outer sheath
Marking text
Outer sheath
colour

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2


(IEC 60092-359)
E.g. "meter" "r" DRAKA NORSK KABEL BU 0,6/1kV P17 1 x 70 mm2 IEC
60331-21 IEC 60332-3-22
Black

www.drakaMOG.com
238

BU 1kV(3).doc
29.12.2006 10:42
Page 2 of 4

BU 0,6/1kV P17, Power cable, Unarmoured


Core identification power cables
Grey (Offwhite)
Single core
Two cores
Grey (Offwhite) - Black
Three cores
Grey (Offwhite) - Black - Red
Four cores
Grey (Offwhite) - Black - Red - Blue
Five cores
Grey (Offwhite) - Black - Red - Blue - Black
Above five cores
Black numbers on white base
Separate earth core
Yellow/green
G / x in cable description
G = one of the core are yellow/green - x = no yellow/green core
From Q3 2007 the core colours
Cenelec HD 308S2 colours:
Single core
Two cores
Two cores + earth
Three cores
Three cores + earth
Four cores
Four cores + earth
Five cores
Above five cores

on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow


Black
Blue - Brown
Blue - Brown - Yellow/green
Brown - Black - Grey
Brown - Black - Grey - Yellow/green
Blue - Brown - Black - Grey
Blue - Brown - Black - Grey - Yellow/green
Blue - Brown - Black - Grey - Black
Black numbers on white base

Range and dimensions


Number of
elements

Cross
section
core, mm

Thickness
Conductor
Insulation
Outer Sheath,
Diameter, mm Thickness, mm
mm

Diameter
outer sheath,
mm

1
1
1
1
1
1
1
1
1
1
2
3G
3
7
19
2
3G
3
4G
5G
12
3
3G
2
3

16
25
35
50
70
95
120
150
185
10
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
6
6

5.15
6.45
7.65
9.0
10.85
12.60
14.20
15.90
17.70
4.05
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.55
2.55
3.15
3.15

10 0.8
11.5 0.8
13 0.8
15 0.8
17 0.8
19.5 0.8
21 1
23.5 1
26 1
8.5 0.5
10 0.8
10.5 0.8
10.5 0.8
14.5 0.8
22.5 1
11 0.8
11.5 0.8
11.5 0.8
13 0.8
14.5 0.8
21 1
13 0.8
13 0.8
13.5 0.8
14.5 0.8

1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

1.1
1.1
1.2
1.2
1.3
1.4
1.4
1.5
1.6
1
1.1
1.1
1.1
1.3
1.5
1.1
1.2
1.1
1.2
1.3
1.4
1.2
1.2
1.2
1.2

www.drakaMOG.com
239

Copper
Weight of Cable
content
Approx.
Approx.
(Kg/Km)
(kg/km)
235
144
350
229
450
308
610
430
840
620
1110
836
1380
1075
1700
1336
2100
1663
160
90
150
28
175
42
175
42
330
98
760
264
185
46
220
69
215
69
265
92
340
114
650
275
295
110
295
110
310
109
380
164

BU 1kV(3).doc
29.12.2006 10:42
Page 3 of 4

BU 0,6/1kV P17, Power cable, Unarmoured


Number of
elements

Cross
section
core, mm

Thickness
Conductor
Insulation
Outer Sheath,
Diameter, mm Thickness, mm
mm

Diameter
outer sheath,
mm

5G
3
3
3
3
3
3

6
10
16
25
35
50
150

3.15
4.05
5.15
6.45
7.65
9.0
15.9

17.5 0.8
16.5 0.8
19 0.8
22.5 1
26 1
30 1.5
48 2

1.0
1.0
1.0
1.2
1.2
1.4
1.8

1.3
1.4
1.4
1.5
1.7
1.9
2.3

Copper
Weight of Cable
content
Approx.
Approx.
(Kg/Km)
(kg/km)
580
272
550
271
780
433
1160
688
1550
927
2120
1293
5910
4020

Ordering information
Part number
801200
801201
801202
801203
801204
801205
801206
801207
801208
801214
801215
801216
801218
801225
801228
801233
801234
801236
801237
801240
801245
801253
801254
801259
801261
801263
801267
801273
801279
801286
801292
801298

Description
BU 0.6/1kV 1X 16mm P17
BU 0.6/1kV 1X 25mm P17
BU 0.6/1kV 1X 35mm P17
BU 0.6/1kV 1X 50mm P17
BU 0.6/1kV 1X 70mm P17
BU 0.6/1kV 1X 95mm P17
BU 0.6/1kV 1X 120mm P17
BU 0.6/1kV 1X 150mm P17
BU 0.6/1kV 1X 185mm P17
BU 0.6/1kV 1X 10mm P17
BU 0,6/1KV 2X 1,5 MM2 P17
BU 0.6/1kV 3G 1.5mm P17
BU 0,6/1KV 3X 1,5 MM2 P17
BU 0,6/1KV 7X 1,5 MM2 P17
BU 0.6/1kV 19X 1.5mm P17
BU 0.6/1kV 2X 2.5mm P17
BU 0.6/1kV 3G 2.5mm P17
BU 0,6/1KV 3X 2,5 MM2 P17
BU 0.6/1kV 4G 2.5mm P17
BU 0.6/1kV 5G 2.5mm P17
BU 0.6/1kV 12X 2.5mm P17
BU 0,6/1KV 3X 4 MM2 P17
BU 0.6/1kV 3G 4mm P17
BU 0,6/1KV 2X 6 MM2 P17
BU 0,6/1KV 3X 6 MM2 P17
BU 0,6/1KV 5G 6 mm P17
BU 0,6/1KV 3X 10 MM2 P17
BU 0,6/1KV 3X 16 MM2 P17
BU 0,6/1KV 3X 25 mm P17
BU 0,6/1KV 3X 35 mm P17
BU 0,6/1KV 3X 50 mm P17
BU 0,6/1KV 3X 150 mm P17

Sheath Colour
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK

Stock item
Yes
-

EAN No. DNK


7021528012002
7021528012019
7021528012026
7021528012033
7021528012040
7021528012057
7021528012064
7021528012071
7021528012088
7021528012149
7021528012156
7021528012163
7021528012187
7021528012255
7021528012286
7021528012330
7021528012347
7021528012361
7021528012378
7021528012408
7021528012453
7021528012538
7021528012545
7021528012590
7021528012613
7021528012637
7021528012675
7021528012736
7021528012798
7021528012866
7021528012927
7021528012989

EL No.
1061203
1061205
1061207
-

Electrical values power cables


Number of
elements

Cross
section
core, mm

1
1

16
25

Max. conductor
resistance at
20C, Ohm/km
1.16
0.734

Max. conductor
resistance at
90C, Ohm/km
1.48
0.936

Reactance at
50Hz,
Ohm/km
0.100
0.097

Reactance at
60Hz,
Ohm/km
0.120
0.117

www.drakaMOG.com
240

Current rating
Short circuit
IEC 60092-352
rating 1
Table B.4,
second,
Ampere
Ampere
96
2240
127
3500

BU 1kV(3).doc
29.12.2006 10:42
Page 4 of 4

BU 0,6/1kV P17, Power cable, Unarmoured


Number of
elements

Cross
section
core, mm

1
1
1
1
1
1
1
1
2
3G
3
7
19
2
3G
3
4G
5G
12
3
3G
2
3
5G
3
3
3
3
3
3

35
50
70
95
120
150
185
10
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
6
6
6
10
16
25
35
50
150

Max. conductor
resistance at
20C, Ohm/km
0.529
0.391
0.27
0.195
0.154
0.126
0.1
1.84
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
4.7
4.7
3.11
3.11
3.11
1.84
1.16
0.734
0.529
0.391
0.126

Max. conductor
resistance at
90C, Ohm/km
0.675
0.499
0.344
0.249
0.196
0.161
0.128
2.35
15.6
15.6
15.6
15.6
15.6
9.64
9.64
9.64
9.64
9.64
15.6
5.99
9.64
3.97
3.97
3.97
2.35
1.48
0.936
0.675
0.499
0.161

Reactance at
50Hz,
Ohm/km
0.093
0.091
0.087
0.085
0.084
0.083
0.083
0.108
0.115
0.115
0.115
0.115
0.115
0.107
0.107
0.107
0.107
0.107
0.115
0.100
0.107
0.094
0.094
0.094
0.088
0.082
0.079
0.078
0.078
0.073

Reactance at
60Hz,
Ohm/km
0.111
0.109
0.105
0.102
0.100
0.100
0.100
0.130
0.138
0.138
0.138
0.138
0.138
0.129
0.129
0.129
0.129
0.129
0.138
0.120
0.129
0.112
0.112
0.112
0.105
0.099
0.095
0.094
0.093
0.088

Current rating
IEC 60092-352
Table B.4,
Ampere
157
196
242
293
339
389
444
72
20
20
16
12
8.5
26
26
21
21
21
13
28
34
44
36
36
50
67
89
110
137
272

Short circuit
rating 1
second,
Ampere
4900
7000
9800
13300
16800
21000
25900
1400
210
210
210
210
210
350
350
350
350
350
350
560
560
840
840
840
1400
2240
3500
4900
7000
21000

Ambient temperature correction factors


Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
241

Minimum Installation
Temperature
-20C

BU(c) 250V(3).doc
29.12.2006 10:20
Page 1 of 3

BU(c) 250V S14 Instrumentation cable, Unarmoured


Fire resistant, flame retardant halogen-free
instrumentation cable. Mud resistant

BU(c) 250V
MGT/EPR/EVA
NEK 606 CodeS14

Operating temperature
Operating Voltage

: 90C
: 250V

Standards applied
Application
Fixed installation for instrumentation, communication, control
and alarm systems in both EX-(Zone 2) and safe areas,
emergency and critical systems where requirement for fire
resistance exists. Meets the mud resistant requirements in
NEK 606.

IEC 60092-376 (2003-05)


IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60331-21
IEC 600754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2

Inner covering

Mica-tape + EP-rubber, IEC 60092-351 (EPR)


Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
No inner covering. (Additional tapes may be applied)

Armour/screen

No armour.

Pair / Triple /
Quad twisting

Outer sheath
Marking text
Outer sheath
colour

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-359)
"meter" "r" DRAKA NORSK KABEL BU(c) 250V S14 8 PAIR 0,75 mm2 FLEX FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22
Grey or Blue

Core identification instrumentation cables


Black - Light Blue
Pair
Triple
Black - Light Blue - Brown
Quad
Black - Light Blue - Brown - Grey

www.drakaMOG.com
242

BU(c) 250V(3).doc
29.12.2006 10:20
Page 2 of 3

BU(c) 250V S14 Instrumentation cable, Unarmoured


Range and dimensions
No of
Number of
cores in
elements
element

Cross
Conductor
section
Diameter,
core, mm mm

Insulation
Thickness,
mm

2
4
8
12
16
19
24
2
4
8
12
16
24
2
4
8
12
16
24
2
4
8
12
16
24

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

2
2
2
2
2
2
2
3
3
3
3
3
3
2
2
2
2
2
2
3
3
3
3
3
3

1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

Electrical values instrumentation cables


Capacitance, approx.
Type
(nF/km)
Unshielded pair 0,75 mm
100

Weight of
Thickness
Diameter
Cable
Outer Sheath, outer sheath,
Approx.
mm
mm
(Kg/Km)
1.1
10.5 0.8
155
1.2
12.5 0.8
235
1.4
17.5 0.8
450
1.5
19.5 0.8
590
1.6
21.5 1
740
1.7
23 1
850
1.8
26.5 1
1060
1.2
12 0.8
205
1.3
14.5 0.8
320
1.5
19.5 0.8
590
1.6
22.5 1
800
1.7
24.5 1
1030
2
30.5 1.5
1500
1.2
13 0.8
230
1.3
15.5 0.8
360
1.5
21 1
680
1.7
24.5 1
940
1.8
26.5 1
1200
2.1
33 1.5
1770
1.3
15 0.8
310
1.4
17.5 0.8
500
1.6
23.5 1
930
1.8
28 1
1310
1.9
30.5 1.5
1680
2.2
37.5 1.5
2480

Copper
content
Approx.
(kg/km)
33
61
116
172
228
269
339
47
89
173
257
341
509
63
118
229
340
451
673
91
174
341
509
677
1011

Inductance, approx,
(mH/km)
0,67

Resistance at 20C, max.


(Ohm/km)
24,8

L/R ratio,
(microH/Ohm)
14,3

Unshielded triple 0,75 mm

100

0,67

24,8

14,3

Unshielded pair 1,5 mm

110

0,63

12,2

26,6

Unshielded triple 1,5 mm

110

0,63

12,2

26,6

Unshielded pair 2,5 mm

125

0,59

7,56

39,0

Unshielded triple 2,5 mm

125

0,59

7,56

39,0

Ordering information
Part number
896806
896818
896830
896836
896842
896845
896848

Description
BU(C) 250V 2PAIR 0.75mm S14
BU(C) 250V 4PAIR 0.75mm S14
BU(C) 250V 8PAIR 0.75mm S14
BU(C) 250V 12PAIR 0.75mm S14
BU(C) 250V 16PAIR 0.75mm S14
BU(C) 250V 19PAIR 0.75mm S14
BU(C) 250V 24PAIR 0.75mm S14

Sheath Colour
GREY
GREY
GREY
GREY
GREY
GREY
GREY

www.drakaMOG.com
243

Stock item
-

EAN No. DNK


7021528968064
7021528968187
7021528968309
7021528968361
7021528968422
7021528968453
7021528968484

EL No.
-

BU(c) 250V(3).doc
29.12.2006 10:20
Page 3 of 3

BU(c) 250V S14 Instrumentation cable, Unarmoured


Part number
896866
896878
896890
896896
896902
896908
897006
897018
897030
897036
897042
897048
897066
897078
897090
897096
897102
897108

Description
BU(C) 250V 2TRIP 0.75mm S14
BU(C) 250V 4TRIP 0.75mm S14
BU(C) 250V 8TRIP 0.75mm S14
BU(C) 250V 12TRIP 0.75mm S14
BU(C) 250V 16TRIP 0.75mm S14
BU(C) 250V 24TRIP 0.75mm S14
BU(C) 250V 2PAIR 1.5mm S14
BU(C) 250V 4PAIR 1.5mm S14
BU(C) 250V 8PAIR 1.5mm S14
BU(C) 250V 12PAIR 1.5mm S14
BU(C) 250V 16PAIR 1.5mm S14
BU(C) 250V 24PAIR 1.5mm S14
BU(C) 250V 2TRIP 1.5mm S14
BU(C) 250V 4TRIP 1.5mm S14
BU(C) 250V 8TRIP 1.5mm S14
BU(C) 250V 12TRIP 1.5mm S14
BU(C) 250V 16TRIP 1.5mm S14
BU(C) 250V 24TRIP 1.5mm S14

Sheath Colour
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY

Stock item
-

EAN No. DNK


7021528968668
7021528968781
7021528968903
7021528968965
7021528969023
7021528969085
7021528970067
7021528970180
7021528970302
7021528970364
7021528970425
7021528970487
7021528970661
7021528970784
7021528970906
7021528970968
7021528971026
7021528971088

EL No.
-

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
244

Minimum Installation
Temperature
-20C

BU(i) 250V(3).doc
29.12.2006 10:26
Page 1 of 3

BU(i) 250V S13 Instrumentation cable, Unarmoured


Fire resistant, flame retardant halogen-free
instrumentation cable. Mud resistant

BU(i) 250V
MGT/EPR/EVA
NEK 606 CodeS13
Operating temperature
Operating Voltage

: 90C
: 250V

Standards applied
Application
Fixed installation for instrumentation, communication, control
and alarm systems in both EX-(Zone 2) and safe areas,
emergency and critical systems where requirement for fire
resistance exists. Meets the mud resistant requirements in
NEK 606.

IEC 60092-376 (2003-05)


IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60331-21
IEC 600754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2

Lay up /
Shielding
Inner covering

Mica-tape + EP-rubber, IEC 60092-351 (EPR)


Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped
with a PETP tape.
No inner covering. (Additional tapes may be applied)

Armour/screen

No armour.

Pair / Triple /
Quad twisting

Outer sheath
Marking text
Outer sheath
colour

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-359)
"meter" "r" DRAKA NORSK KABEL BU(i) 250V S13 8 PAIR 0,75 mm2 FLEX FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22
Grey or Blue

www.drakaMOG.com
245

BU(i) 250V(3).doc
29.12.2006 10:26
Page 2 of 3

BU(i) 250V S13 Instrumentation cable, Unarmoured


Core identification instrumentation cables
Black - Light Blue
Pair
Triple
Black - Light Blue - Brown
Quad
Black - Light Blue - Brown - Grey
Range and dimensions
No of
Number of
cores in
elements
element

Cross
Conductor
section
Diameter,
core, mm mm

Insulation
Thickness,
mm

1
1
2
2
4
8
12
16
24
1
2
4
8
12
16
24
1
1
2
2
4
8
12
12
16
24
1
1
2
4
8
12
16
24
1

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
3
2

1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2

Electrical values instrumentation cables


Capacitance, approx.
Type
(nF/km)
Shielded pair 0,75 mm
110
Shielded triple 0,75 mm
110
Shielded pair 1,5 mm
125

Weight of
Thickness
Diameter
Cable
Outer Sheath, outer sheath,
Approx.
mm
mm
(Kg/Km)
1
7.5 0.5
95
1
7.5 0.5
95
1.2
11 0.8
170
1.2
11 0.8
170
1.2
13 0.8
265
1.4
17.5 0.8
510
1.6
21 1
720
1.7
23.5 1
920
1.9
29 1
1340
1
7.5 0.5
110
1.2
12 0.8
205
1.3
14 0.8
350
1.5
19.5 0.8
650
1.7
23.5 1
930
1.8
26 1
1210
2.1
32.5 1.5
1770
1
8.5 0.5
135
1
8.5 0.5
135
1.3
13.5 0.8
250
1.3
13.5 0.8
250
1.4
16 0.8
420
1.6
22 1
790
1.7
26 1
1100
1.7
26 1
1100
1.9
29.5 1
1460
2.2
36.5 1.5
2160
1.1
9.5 0.5
165
1.1
9.5 0.5
165
1.3
14.5 0.8
320
1.4
17.5 0.8
540
1.7
23.5 1
1030
1.9
29 1
1480
2
32.5 1.5
1920
2.4
40.5 2
2880
1.1
9.5 0.5
170

Inductance, approx,
(mH/km)
0,67
0,67
0,63

Resistance at 20C, max.


(Ohm/km)
24,8
24,8
12,2

www.drakaMOG.com
246

Copper
content
Approx.
(kg/km)
18.5
18.5
37
37
74
147
220
293
440
26
51
102
203
305
407
610
35
35
69
69
138
275
412
412
549
824
49
49
97
194
387
582
775
1163
54

L/R ratio,
(microH/Ohm)
14,3
14,3
26,6

BU(i) 250V(3).doc
29.12.2006 10:26
Page 3 of 3

BU(i) 250V S13 Instrumentation cable, Unarmoured


Type
Shielded triple 1,5 mm
Shielded pair 2,5 mm
Shielded triple 2,5 mm

Capacitance, approx.
(nF/km)
125
145
145

Inductance, approx,
(mH/km)
0,63
0,59
0,59

Resistance at 20C, max.


(Ohm/km)
12,2
7,56
7,56

L/R ratio,
(microH/Ohm)
26,6
39,0
39,0

Ordering information
Part number
896200
896201
896206
896207
896218
896230
896236
896242
896248
896260
896266
896278
896290
896296
896302
896308
896400
896401
896406
896407
896418
896430
896436
896437
896442
896448
896460
896461
896466
896478
896490
896496
896502
896508
896600

Description
BU(I) 250V 1PAIR 0.75mm S13
BU(I) 250V 1PAIR 0.75mm S13
BU(I) 250V 2PAIR 0.75mm S13
BU(I) 250V 2PAIR 0.75mm S13
BU(I) 250V 4PAIR 0.75mm S13
BU(I) 250V 8PAIR 0.75mm S13
BU(I) 250V 12PAIR 0.75mm S13
BU(I) 250V 16PAIR 0.75mm S13
BU(I) 250V 24PAIR 0.75mm S13
BU(I) 250V 1TRIP 0.75mm S13
BU(I) 250V 2TRIP 0.75mm S13
BU(I) 250V 4TRIP 0.75mm S13
BU(I) 250V 8TRIP 0.75mm S13
BU(I) 250V 12TRIP 0.75mm S13
BU(I) 250V 16TRIP 0.75mm S13
BU(I) 250V 24TRIP 0.75mm S13
BU(I) 250V 1PAIR 1.5mm S13
BU(I) 250V 1PAIR 1.5mm S13
BU(I) 250V 2PAIR 1.5mm S13
BU(I) 250V 2PAIR 1.5mm S13
BU(I) 250V 4PAIR 1.5mm S13
BU(I) 250V 8PAIR 1.5mm S13
BU(I) 250V 12PAIR 1.5mm S13
BU(I) 250V 12PAIR 1.5mm S13
BU(I) 250V 16PAIR 1.5mm S13
BU(I) 250V 24PAIR 1.5mm S13
BU(I) 250V 1TRIP 1.5mm S13
BU(I) 250V 1TRIP 1.5mm S13
BU(I) 250V 2TRIP 1.5mm S13
BU(I) 250V 4TRIP 1.5mm S13
BU(I) 250V 8TRIP 1.5mm S13
BU(I) 250V 12TRIP 1.5mm S13
BU(I) 250V 16TRIP 1.5mm S13
BU(I) 250V 24TRIP 1.5mm S13
BU(I) 250V 1PAIR 2.5mm S13

Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
BLUE
GREY
GREY
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
GREY
GREY

Stock item
-

EAN No. DNK


7021528962000
7021528962017
7021528962062
7021528962079
7021528962185
7021528962307
7021528962369
7021528962420
7021528962482
7021528962604
7021528962666
7021528962789
7021528962901
7021528962963
7021528963021
7021528963083
7021528964004
7021528964011
7021528964066
7021528964073
7021528964189
7021528964301
7021528964363
7021528964370
7021528964424
7021528964486
7021528964608
7021528964615
7021528964660
7021528964783
7021528964905
7021528964967
7021528965025
7021528965087
7021528966008

EL No.
-

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
247

Minimum Installation
Temperature
-20C

RFOU 12_20_24kV(3).doc
29.12.2006 11:19
Page 1 of 3

FlexFlame RFOU 12/20(24) kV P19/P21 Power cable


Flame retardant halogen-free medium voltage
(MV) cable. Mud resistant

RFOU 12/20(24) kV
EPR/EPR/TCWB/EVA
NEK 606 CodeP19/P21

Operating temperature
Operating Voltage

: 90C
: 12/20(24) kV

Standards applied

Application
Fixed installation for medium voltage (MV) power in both
EX- and safe areas, general purposes. For installation in
areas exposed to MUD and drilling/cleaning fluids.

IEC 60092-354
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 600754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Conductor screen
semiconductive
Insulation
Insulation screen
semicoductive

Tinned stranded and compressed copper (STCC), IEC 60228 class 2


Semiconductive layer (EP-rubber)
R

Lay up / Shielding
Inner covering
Tape over inner covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Outer sheath colour

EP-rubber, IEC 60092-351 (EPR)


Semiconductive layer (EP-rubber)
Cores are laid up together. Cores are identified by White, Black or Red
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoset compound
PET tape

Tinned annealed copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound,


SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA NORSK KABEL RFOU 12/20(24)KV P19/P21
3 x 95/50 mm2 IEC 60332-3-22
Red

www.drakaMOG.com
248

RFOU 12_20_24kV(3).doc
29.12.2006 11:19
Page 2 of 3

FlexFlame RFOU 12/20(24) kV P19/P21 Power cable


Range and dimensions
Cross Cross
Number
Conductor
section section
of
Diameter,
core,
screen,
elements
mm
mm
mm
1
16
13
5.2

Thickness
Insulation
Inner
Thickness,
covering,
mm
mm
5.5
1.0

Diameter
inner
covering,
mm
22.5 1.0

Diameter
Braid
Wire,
mm
0.3

Thickness
Outer
Sheath,
mm
1.6

25

13

6.5

5.5

1.0

24 1.0

0.3

1.7

1
1
1
1
1
1

35
50
70
95
120
150

13
15
13
17
15
15

7.4
8.8
10.3
12.1
13.6
15.1

5.5
5.5
5.5
5.5
5.5
5.5

1.2
1.2
1.2
1.2
1.3
1.3

25 1.5
26.5 1.5
28 1.5
30 1.5
31.5 1.5
33 1.5

0.3
0.3
0.3
0.3
0.3
0.3

1.8
2.0
2.1
2.1
2.1
2.2

185

18

16.8

5.5

1.4

35 1.5

0.3

2.2

240

23

19.1

5.5

1.4

37.5 1.5 0.3

2.4

300

28

21.5

5.5

1.4

41.0 2.0 0.3

2.6

16

31

5.2

5.5

1.4

48 2.0

0.4

2.6

25

35

6.5

5.5

1.4

51 2.0

0.4

2.7

35

35

7.4

5.5

1.4

0.4

2.8

50

35

8.8

5.5

1.8

53 2.0
57.0
2.0

0.4

3.0

70

35

10.3

5.5

1.8

60 2.5

0.4

3.1

95

50

12.1

5.5

2.0

0.5

3.3

120

60

13.6

5.5

2.0

0.5

3.4

150

75

15.1

5.5

2.0

0.5

3.5

185

45

16.8

5.5

2.0

0.5

3.7

240

55

19.1

5.5

2.2

0.5

3.9

64.5
3.0
67.5
3.0
71.0
3.0
75.0
3.5
79.5
3.5

Diameter
outer
sheath,
mm
28 1.5
29.5
1.5
31 2
32.5 2
34 2.0
36 2
38 2
40 2.5
41.5
2.5
45.0
2.5
47.0
3.0
55.5
3.0
58.5
3.0
61 3.0
65.5
3.5
68.5
3.5
73.5
4.0

Weight
of Cable
Approx.
(Kg/Km)
1200

Copper
content
Approx.
(kg/km)
495

1300

561

1450
1700
2000
2400
2650
3000

671
811
1001
1210
1491
1835

3500

2201

4350

2915

5200

3640

9300

4112

4950

1558

5500

1885

6500

2276

7500

2979

9300

4112

77 4.0

10250

4761

11700

5822

12950

6615

15900

8797

80.0
4.5
85.0
4.5
90.0
4.5

Ordering information
Part number
804100
804101
804102
804103
804104
804105
804106
804107
804108
804109
804110
804120
804121

Description
RFOU 12/20KV 1X 16/13mm P19
RFOU 12/20KV 1X 25/13mm P19
RFOU 12/20KV 1X 35/13mm P19
RFOU 12/20KV 1X 50/15mm P19
RFOU 12/20KV 1X 70/13mm P19
RFOU 12/20KV 1X 95/17mm P19
RFOU 12/20KV 1X120/15mm P19
RFOU 12/20KV 1X150/15mm P19
RFOU 12/20KV 1X185/18mm P19
RFOU 12/20KV 1X240/23mm P19
RFOU 12/20KV 1X300/28mm P19
RFOU 12/20KV 3X 16/31mm P19
RFOU 12/20KV 3X 25/35mm P19

Sheath Colour
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED

www.drakaMOG.com
249

Stock item
-

EAN No. DNK


7021528041002
7021528041019
7021528041026
7021528041033
7021528041040
7021528041057
7021528041064
7021528041071
7021528041088
7021528041095
7021528041101
7021528041200
7021528041217

EL No.
-

RFOU 12_20_24kV(3).doc
29.12.2006 11:19
Page 3 of 3

FlexFlame RFOU 12/20(24) kV P19/P21 Power cable


Part number
804122
804123
804124
804125
804126
804127
804128
804129

Description
RFOU 12/20KV 3X 35/35mm P19
RFOU 12/20KV 3X 50/35mm P19
RFOU 12/20KV 3X 70/35mm P19
RFOU 12/20KV 3X 95/50mm P19
RFOU 12/20KV 3X120/60mm P19
RFOU 12/20KV 3X150/75mm P19
RFOU 12/20KV 3X185/45mm P19
RFOU 12/20KV 3X240/55mm P19

Sheath Colour
RED
RED
RED
RED
RED
RED
RED
RED

Stock item
-

EAN No. DNK


7021528041224
7021528041231
7021528041248
7021528041255
7021528041262
7021528041279
7021528041286
7021528041293

EL No.
-

Electrical values power cables


Number Cross Cross Conductor
Max.
of
section section
type 2
conductor
elements core, screen,
resistance
mm
mm
at 20C,
Ohm/km

1
1
1
1
1
1
1
1
1
1
1
3
3
3
3
3
3
3
3
3
3

16
25
35
50
70
95
120
150
185
240
300
16
25
35
50
70
95
120
150
185
240

13
13
13
15
13
17
15
15
18
23
28
31
35
35
35
35
50
60
75
45
55

STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC

1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762

Max.
conductor
resistance
at 90C,
Ohm/km

1.479
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972

Reactance Reactance Capacitans


at 50Hz,
at 60Hz, per phase,
Ohm/km
Ohm/km
nF/km

0.164
0.154
0.149
0.140
0.133
0.127
0.124
0.119
0.116
0.112
0.108
0.143
0.133
0.128
0.121
0.115
0.109
0.105
0.102
0.099
0.095

0.197
0.185
0.178
0.169
0.160
0.152
0.149
0.142
0.139
0.134
0.130
0.172
0.160
0.153
0.145
0.135
0.131
0.126
0.122
0.118
0.114

170
190
200
220
250
270
300
320
340
380
410
170
190
200
220
250
270
300
320
340
380

Current
rating
IEC
60092352
Table
B.4,
Ampere
96
127
157
196
242
293
339
389
444
522
601
67
89
110
137
169
205
237
272
311
365

Short
circuit
rating 1
second,
Ampere

2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600

Ambient temperature correction factors


Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
15 x D

Minimum Bending Radius


Fixed Installed
9xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
250

Minimum Installation
Temperature
-20C

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 1 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Flame retardant halogen-free power
cable. Mud resistant

RFOU 0,6/1kV
EPR/EPR/TCWB/EVA
NEK 606 CodeP1/P8

Operating temperature
Operating Voltage

: 90C
: 0,6/1kV

Standards applied
Application
Fixed installation for power,control and lighting in both EX- and
safe areas, general purposes. For installation in areas exposed
to MUD and drilling/cleaning fluids. Meets the MUD resistance
requirement in NEK 606.

IEC 60092-353
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour

R
F

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


EP-rubber, IEC 60092-351 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoset compound
PET tape

Tinned annealed copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound,


SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 3 x 35/16 mm2 IEC
60332-3-22 ETL Classified No. 3067229
DRAKA 01 = Draka Norsk Kabel,
Black

www.drakaMOG.com
251

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 2 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross
Number
Conductor
section section
of
Diameter,
core,
screen,
elements
mm
mm
mm
1
16
2.5
5.15

Thickness
Insulation
Inner
Thickness,
covering,
mm
mm
1.0
1.1

Diameter
Braid
Wire,
mm
0.2

Thickness
Outer
Sheath,
mm
1.2

0.2

1.2

0.3

1.2
1.2
1.2

Diameter
inner
covering,
mm
9.5 0.5
11.5
0.8
12.5
0.8
14.5
0.8
16.5
0.8
18.5
0.8
20.5 1
22.5 1
24.5 1

Diameter
outer
sheath,
mm
13 0.8
14.5
0.8

Weight
of Cable
Approx.
(Kg/Km)
360

Copper
content
Approx.
(kg/km)
190

25

6.45

1.2

1.1

490

283

35

7.65

1.2

1.1

1.3

16 0.8

650

408

50

9.0

1.4

1.1

0.3

1.4

18.5
0.8

830

528

70

10

10.85

1.4

1.1

0.3

1.4

20.5 1

1100

744

95

10

12.60

1.6

1.1

0.3

1.5

23 1

1380

961

1
1
1

120
150
185

10
10
10

14.20
15.90
17.70

1.6
1.8
2.0

0.3
0.3
0.3

1.6
1.6
1.7

1710
2040
2480

1224
1485
1837

27.5 1

0.3

1.8

3130

2372

1.2

30.5
1.5

0.3

1.9

3830

2952

1.0

1.1

9.5 0.5 0.2

1.2

270

80

1.6

1.0

1.1

10 0.8

0.2

1.2

295

94

1.6

1.0

1.1

11 0.8

0.3

1.3

380

139

1.5

1.6

1.0

1.1

10 0.8

0.2

1.2

295

94

1.5

1.6

1.0

1.1

11 0.8

0.3

1.3

380

139

1.5

1.6

1.0

1.1

12 0.8

0.3

1.3

440

170

1.5

1.6

1.0

1.1

0.3

1.3

500

198

12

1.5

10

1.6

1.0

1.1

0.3

1.5

21.5 1

740

300

19
27

1.5
1.5

10
10

1.6
1.6

1.0
1.0

1.2
1.2

13 0.8
17.5
0.8
20.5 1
24.5 1

25 1
27 1
29.5 1
32.5
1.5
35.5
1.5
12.5
0.8
13.5
0.8
14.5
0.8
13.5
0.8
14.5
0.8
15.5
0.8
17 0.8

240

16

20.15

2.2

1.2

300

16

22.60

2.4

1.5

1.6

3G

1.5

4G

1.5

0.3
0.3

1.6
1.8

1020
1360

413
551

37

1.5

16

1.6

1.0

1.2

27.5 1

0.3

1.9

1720

716

5G

1.5

1.6

1.0

1.1

12 0.8

0.3

1.3

440

170

7G
2

1.5
2.5

1.6
2.0

1.0
1.0

1.1
1.1

13 0.8
10.5

0.3
0.2

1.3
1.2

25 1
29.5 1
32.5
1.5
15.5
0.8
17 0.8
13.5

500
320

197
98

www.drakaMOG.com
252

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 3 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Cross Cross
Number
Conductor Insulation
section section
of
Diameter, Thickness,
core,
screen,
elements
mm
mm
mm
mm

Thickness
Inner
covering,
mm

Diameter
inner
covering,
mm
0.8

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

3G

2.5

2.0

1.0

1.1

11 0.8

0.3

1.3

2.5

2.0

1.0

1.1

11 0.8

0.3

1.3

4G
5G
4
5

2.5
2.5
2.5
2.5

6
6

2.0
2.0
2.0
2.0

1.0
1.0
1.0
1.0

1.1
1.1
1.1
1.1

0.3
0.3
0.3
0.3

1.3
1.4
1.3
1.4

2.5

2.0

1.0

1.1

0.3

1.4

12

2.5

10

2.0

1.0

1.2

0.3

1.6

19

2.5

10

2.0

1.0

1.2

12 0.8
13 0.8
12 0.8
13 0.8
14.5
0.8
19.5
0.8
23 1

0.3

1.7

27

2.5

16

2.0

1.0

1.2

27.5 1

0.3

1.9

37

2.5

16

2.0

1.0

1.4

0.3

4G

2.55

1.0

1.1

0.3

31.5
1.5
13.5
0.8
14.5
0.8
11.5
0.8
12 0.8
13.5
0.8
14.5
0.8
12 0.8
14.5
0.8
12.5
0.8
13.5
0.8

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

390

152

390

152

460
530
460
530

192
215
192
215

630

277

23.5 1

950

424

27.5 1
32.5
1.5
36.5
1.5

1310

609

1760

817

2310

1074

1.4

17 0.8

560

247

0.3

1.4

18.5
0.8

630

276

0.3

1.3

15 0.8

410

157

0.3

1.3

16 0.8

480

210

0.3

1.4

17 0.8

560

247

0.3

1.4

660

299

0.3

1.3

480

210

0.3

1.4

660

299

0.3

1.3

500

209

0.3

1.4

590

264

700

334

700

334

590

264

820

388

670

299

7G

2.5

2.0

1.0

1.1

2.55

1.0

1.1

2.55

1.0

1.1

2.55

1.0

1.1

2.55

1.0

1.1

3G

2.55

1.0

1.1

5G

2.55

1.0

1.1

3.15

1.0

1.1

3.15

1.0

1.1

3.15

1.0

1.1

15 0.8

0.3

1.4

4G

3.15

1.0

1.1

15 0.8

0.3

1.4

3G

3.15

1.0

1.1

0.3

1.4

5G

3.15

1.0

1.1

0.3

1.5

10

10

4.05

1.0

1.1

10

10

4.05

1.0

1.1

10

10

4.05

1.0

1.1

3G

10

4.05

1.0

1.1

5G
4G

10
10

4.05
4.05

1.0
1.0

1.2
1.1

16

16

5.15

1.0

1.1

16

16

5.15

1.0

1.1

16

16

5.15

1.0

1.2

13.5
0.8
16.5
0.8
14.5
0.8
15.5
0.8
17 0.8
15.5
0.8
19 0.8
17 0.8
16.5
0.8
17.5
0.8
20 1

18.5
0.8
16 0.8
18.5
0.8
16.5
0.8
17.5
0.8
18.5
0.8
18.5
0.8
17.5
0.8
20.5 1

0.3

1.4

0.3

1.4

0.3

1.5

0.3

1.4

0.3
0.3

1.5
1.5

18.5
0.8
19.5
0.8
21 1
19.5
0.8
23 1
21 1

0.4

1.5

21 1

950

477

0.4

1.5

22.5 1

1120

621

0.4

1.6

24.5 1

1390

799

www.drakaMOG.com
253

Diameter
outer
sheath,
mm
0.8
14.5
0.8
14.5
0.8
16 0.8
17 0.8
16 0.8
17 0.8
18.5
0.8

780

389

940

494

780

387

1130
940

600
494

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 4 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Cross Cross
Number
Conductor
section section
of
Diameter,
core,
screen,
elements
mm
mm
mm
4G
16
5.15
5G
16
5.15

Thickness
Insulation
Inner
Thickness,
covering,
mm
mm
1.0
1.2
1.0
1.2

3G

16

5.15

1.0

1.1

2
3
4
4G
3G

25
25
25
25
25

16
16
16
-

6.45
6.45
6.45
6.45
6.45

1.2
1.2
1.2
1.2
1.2

1.2
1.2
1.2
1.2
1.2

Diameter
inner
covering,
mm
20 1
22 1
17.5
0.8
20.5 1
22 1
24 1
24 1
22 1

Diameter
Braid
Wire,
mm
0.3
0.3

Thickness
Outer
Sheath,
mm
1.6
1.6

Diameter
outer
sheath,
mm
24 1
26 1

Weight
of Cable
Approx.
(Kg/Km)
1310
1530

Copper
content
Approx.
(kg/km)
727
873

0.3

1.5

22 1

1050

566

0.4
0.3
0.3
0.3
0.3

1.6
1.6
1.7
1.7
1.6

1340
1560
1900
1880
1510

685
887
1116
1091
837

26.5 1

0.3

1.8

2250

1345

1.2
1.2

23 1
24.5 1

0.3
0.3

1.7
1.7

1580
1920

817
1126

1.2

1.2

27 1

0.3

1.8

2360

1435

7.65

1.2

1.2

27 1

0.3

1.8

2360

1435

25

7.65
9.0

1.2
1.4

1.2
1.2

30 1.5
28.5 1

0.3
0.4

1.9
1.9

2840
2660

1768
1596

50

25

9.0

1.4

1.4

32 1.5

0.4

3290

2025

4G
5G

50
50

9.0
9.0

1.4
1.4

1.4
1.4

0.3
0.4

2
2.1

3200
4000

1939
2498

70

35

10.85

1.4

1.2

0.6

1.9

3010

1756

70

35

10.85

1.4

1.4

0.5

3690

2346

70

35

10.85

1.4

1.4

0.5

2.2

43 2

4540

2967

4G

70

10.85

1.4

1.4

0.4

2.2

42.5 2

4410

2839

5G
5
2

70
70
95

35
50

10.85
10.85
12.60

1.4
1.4
1.6

1.4
1.4
1.4

0.4
0.4
0.6

2.3
2.3
2.1

46.5 2
46.5 2
41.5 2

5280
5360
3940

3465
3547
2292

95

50

12.60

1.6

1.4

0.5

2.2

43.5 2

4790

3091

4
4G

95
95

50
-

12.60
12.60

1.6
1.6

1.4
1.4

0.5
0.4

2.4
2.4

3973
3749

120

14.20

1.6

1.6

0.5

2.7

8580

5873

2
3

120
120

60
60

14.20
14.20

1.6
1.6

1.4
1.4

0.6
0.6

2.2
2.3

4790
5930

2875
3953

120

60

14.20

1.6

1.6

46 2

0.6

2.5

7410

5071

4G

120

14.20

1.6

1.6

46 2

0.4

2.5

7090

4754

4G

150

15.90

1.8

1.6

51 2.5

0.5

2.7

48.5 2
48 2
58.5
2.5
45 2
48 2
53.5
2.5
52.5
2.5
58.5
2.5

5980
5750

5G

32 1.5
35 1.5
30.5
1.5
33 1.5
36.5
1.5
36.5
1.5
40.5 2
40.5 2
35 1.5
37.5
1.5
41.5 2
41.5 2
50.5
2.5
38 1.5
41 2

25.5 1
26 1
28.5 1
28.5 1
26 1
31.5
1.5
27.5 1
29 1
31.5
1.5
31.5
1.5
35 1.5
34 1.5
37.5
1.5
37 1.5
41 2
36.5
1.5
39 1.5

5G

25

6.45

1.2

1.2

2
3

35
35

16
16

7.65
7.65

1.2
1.2

35

16

7.65

4G

35

5G
3

35
50

8700

5845

4G

185

17.7

2.0

1.8

0.5

2.9

64.5 3

10690

7238

4G
4
4

240
185
240

95
120

19.1
16.8
19.1

2.2
2.0
2.2

1.8
1.6
2.0

0.4
0.6
0.6

2.8
2.8
3.0

72 3.5
64 3
72 3.5

13650
11350
14800

10054
6598
8777

56.5
2.5
62 2.5
55 2
62 2.5

Ordering information
Part number
Description
800000
RFOU 0.6/1kV 1X 16/2.5 P1/P8
800001
RFOU 0.6/1kV 1X 25/4mm P1/P8

Sheath Colour
BLACK
BLACK

www.drakaMOG.com
254

Stock item
-

EAN No. DNK


7021528000009
7021528000016

EL No.
1044206

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 5 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Part number
800002
800003
800004
800005
800006
800007
800008
800009
800010
800015
800016
800017
800018
800019
800020
800021
800022
800023
800024
800025
800026
800028
800029
800030
800032
800033
800034
800035
800036
800037
800038
800039
800040
800041
800043
800044
800045
800046
800047
800048
800049
800050
800051
800052
800053
800054
800055
800056
800057
800058
800059
800060
800061
800062
800063
800064
800065
800066
800067
800068
800069

Description
RFOU 0.6/1kV 1X 35/6mm P1/P8
RFOU 0.6/1kV 1X 50/6mm P1/P8
RFOU 0.6/1kV 1X 70/6mm P1/P8
RFOU 0.6/1kV 1X 95/10mm P1/P8
RFOU 0.6/1kV 1X 120/10 P1/P8
RFOU 0.6/1kV 1X 150/10 P1/P8
RFOU 0.6/1kV 1X 185/10 P1/P8
RFOU 0.6/1kV 1X 240/16 P1/P8
RFOU 0.6/1kV 1X 300/16 P1/P8
RFOU 0.6/1kV 2X 1.5/4mm P1/P8
RFOU 0.6/1kV 3G 1.5mm P1/P8
RFOU 0.6/1kV 4G 1.5mm P1/P8
RFOU 0.6/1kV 3X 1.5/4mm P1/P8
RFOU 0.6/1kV 4X 1.5/6mm P1/P8
RFOU 0.6/1kV 5X 1.5/6mm P1/P8
RFOU 0.6/1kV 7X 1.5/6mm P1/P8
RFOU 0.6/1kV 12X 1.5/10 P1/P8
RFOU 0.6/1kV 19X 1.5/10 P1/P8
RFOU 0.6/1kV 27X 1.5/10 P1/P8
RFOU 0.6/1kV 37X 1.5/16 P1/P8
RFOU 0.6/1kV 5G 1.5mm P1/P8
RFOU 0.6/1kV 7G 1.5mm P1/P8
RFOU 0.6/1kV 2X 2.5/4mm P1/P8
RFOU 0.6/1kV 3G 2.5mm P1/P8
RFOU 0.6/1kV 3X 2.5/6mm P1/P8
RFOU 0.6/1kV 4G 2.5mm P1/P8
RFOU 0.6/1kV 5G 2.5mm P1/P8
RFOU 0.6/1kV 4X 2.5/6mm P1/P8
RFOU 0.6/1kV 5X 2.5/6mm P1/P8
RFOU 0.6/1kV 7X 2.5/6mm P1/P8
RFOU 0.6/1kV 12X 2.5/10 P1/P8
RFOU 0.6/1kV 19X 2.5/10 P1/P8
RFOU 0.6/1kV 27X 2.5/16 P1/P8
RFOU 0.6/1kV 37X 2.5/16 P1/P8
RFOU 0.6/1kV 4G 4mm P1/P8
RFOU 0.6/1kV 7G 2.5mm P1/P8
RFOU 0.6/1kV 2X 4/6mm P1/P8
RFOU 0.6/1kV 3X 4/6mm P1/P8
RFOU 0.6/1kV 4X 4/6mm P1/P8
RFOU 0.6/1kV 5X 4/6mm P1/P8
RFOU 0.6/1kV 3G 4mm P1/P8
RFOU 0.6/1kV 5G 4mm P1/P8
RFOU 0.6/1kV 2X 6/6mm P1/P8
RFOU 0.6/1kV 3X 6/6mm P1/P8
RFOU 0.6/1kV 4X 6/6mm P1/P8
RFOU 0.6/1kV 4G 6mm P1/P8
RFOU 0.6/1kV 3G 6mm P1/P8
RFOU 0.6/1kV 5G 6mm P1/P8
RFOU 0.6/1kV 2X 10/10mm P1/P8
RFOU 0.6/1kV 3X 10/10mm P1/P8
RFOU 0.6/1kV 4X 10/10mm P1/P8
RFOU 0.6/1kV 3G 10mm P1/P8
RFOU 0.6/1kV 5G 10mm P1/P8
RFOU 0.6/1kV 4G 10mm P1/P8
RFOU 0.6/1kV 2X 16/16mm P1/P8
RFOU 0.6/1kV 3X 16/16mm P1/P8
RFOU 0.6/1kV 4X 16/16mm P1/P8
RFOU 0.6/1kV 4G 16mm P1/P8
RFOU 0.6/1kV 5G 16mm P1/P8
RFOU 0.6/1kV 3G 16mm P1/P8
RFOU 0.6/1kV 2X 25/16mm P1/P8

Sheath Colour
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK

www.drakaMOG.com
255

Stock item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-

EAN No. DNK


7021528000023
7021528000030
7021528000047
7021528000054
7021528000061
7021528000078
7021528000085
7021528000092
7021528000108
7021528000153
7021528000160
7021528000177
7021528000184
7021528000191
7021528000207
7021528000214
7021528000221
7021528000238
7021528000245
7021528000252
7021528000269
7021528000283
7021528000290
7021528000306
7021528000320
7021528000337
7021528000344
7021528000351
7021528000368
7021528000375
7021528000382
7021528000399
7021528000405
7021528000412
7021528000436
7021528000443
7021528000450
7021528000467
7021528000474
7021528000481
7021528000498
7021528000504
7021528000511
7021528000528
7021528000535
7021528000542
7021528000559
7021528000566
7021528000573
7021528000580
7021528000597
7021528000603
7021528000610
7021528000627
7021528000634
7021528000641
7021528000658
7021528000665
7021528000672
7021528000689
7021528000696

EL No.
1044207
1044208
1044210
1044211
1044213
1044214
1044215
1044220
1044240
1044260
1044305
1044307
1044312
1044319
1044327
1044337
1044221
1044241
1044261
1044355
1044357
1044362
1044369
1044377
1044387
1044222
1044242
1044262
1044223
1044243
1044263
1044224
1044244
1044264
1044225
1044245
1044265
1044226

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 6 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Part number
800070
800071
800072
800073
800074
800075
800076
800077
800078
800079
800082
800083
800084
800085
800087
800088
800089
800090
800091
800092
800094
800095
800096
800097
800099
800100
800101
800105
800106
800108
800110
803904
803905
803906

Description
RFOU 0.6/1kV 3X 25/16mm P1/P8
RFOU 0.6/1kV 4X 25/16mm P1/P8
RFOU 0.6/1kV 4G 25mm P1/P8
RFOU 0.6/1kV 3G 25mm P1/P8
RFOU 0.6/1kV 5G 25mm P1/P8
RFOU 0.6/1kV 2X 35/16mm P1/P8
RFOU 0.6/1kV 3X 35/16mm P1/P8
RFOU 0.6/1kV 4X 35/16mm P1/P8
RFOU 0.6/1kV 4G 35mm P1/P8
RFOU 0.6/1kV 5G 35mm P1/P8
RFOU 0.6/1kV 3X 50/25mm P1/P8
RFOU 0.6/1kV 4X 50/25mm P1/P8
RFOU 0.6/1kV 4G 50mm P1/P8
RFOU 0.6/1kV 5G 50mm P1/P8
RFOU 0.6/1kV 2X 70/35mm P1/P8
RFOU 0.6/1kV 3X 70/35mm P1/P8
RFOU 0.6/1kV 4X 70/35mm P1/P8
RFOU 0.6/1kV 4G 70mm P1/P8
RFOU 0.6/1kV 5G 70mm P1/P8
RFOU 0.6/1kV 5X 70/35mm P1/P8
RFOU 0.6/1kV 2X 95/50mm P1/P8
RFOU 0.6/1kV 3X 95/50mm P1/P8
RFOU 0.6/1kV 4X 95/50mm P1/P8
RFOU 0.6/1kV 4G 95mm P1/P8
RFOU 0.6/1kV 5G 120mm P1/P8
RFOU 0.6/1kV 2X 120/60 P1/P8
RFOU 0.6/1kV 3X 120/60 P1/P8
RFOU 0.6/1kV 4X 120/60 P1/P8
RFOU 0.6/1kV 4G 120mm P1/P8
RFOU 0.6/1kV 4G 150mm P1/P8
RFOU 0.6/1kV 4G 185mm P1/P8
RFOU 0.6/1kV 4G 240mm2 P1/P8
RFOU 0.6/1kV 4X 185/95 P1/P8
RFOU 0.6/1kV 4X 240/120 P1/P8

Sheath Colour
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK

Stock item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-

EAN No. DNK


7021528000702
7021528000719
7021528000726
7021528000733
7021528000740
7021528000757
7021528000764
7021528000771
7021528000788
7021528000795
7021528000825
7021528000832
7021528000849
7021528000856
7021528000870
7021528000887
7021528000894
7021528000900
7021528000917
7021528000924
7021528000948
7021528000955
7021528000962
7021528000979
7021528000993
7021528001006
7021528001013
7021528001051
7021528001068
7021528001082
7021528001105
7021528039047
7021528039054
7021528039061

EL No.
1044246
1044266
1044247
1044267
1044248
1044268
1044249
1044269
1044250
1044270
1044251
-

Electrical values power cables


Number
of
elements

1
1
1
1
1
1
1
1
1
1
1
2
3G
4G
3
4
5
7
12

Cross
section
core,
mm
16
25
35
50
70
95
120
150
185
240
300
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

Cross
section
screen,
mm
2.5
4
6
6
10
10
10
10
10
16
16
4
4
6
6
6
10

Conductor
type 2

STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC

Max.
conductor
resistance at
20C,
Ohm/km
1.16
0.734
0.529
0.391
0.27
0.195
0.154
0.126
0.1
0.0762
0.0607
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2

Max.
conductor
resistance at
90C,
Ohm/km
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6

Reactance
at 50Hz,
Ohm/km

0.116
0.110
0.106
0.104
0.099
0.097
0.094
0.092
0.091
0.089
0.087
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110

www.drakaMOG.com
256

Reactance
at 60Hz,
Ohm/km

0.140
0.132
0.128
0.125
0.119
0.116
0.113
0.111
0.109
0.107
0.105
0.132
0.132
0.132
0.132
0.132
0.132
0.132
0.132

Current
rating IEC
60092-352
Table B.4,
Ampere
96
127
157
196
242
293
339
389
444
522
601
20
20
16
16
16
13.5
12
10

Short
circuit
rating 1
second,
Ampere
2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
210
210
210
210
210
210
210
210

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 7 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Number
of
elements

19
27
37
5G
7G
2
3G
3
4G
5G
4
5
7
12
19
27
37
4G
7G
2
3
4
5
3G
5G
2
3
4
4G
3G
5G
2
3
4
3G
5G
4G
2
3
4
4G
5G
3G
2
3
4
4G
3G
5G
2
3
4
4G
5G
3
4
4G

Cross
section
core,
mm
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
2.5
4
4
4
4
4
4
6
6
6
6
6
6
10
10
10
10
10
10
16
16
16
16
16
16
25
25
25
25
25
25
35
35
35
35
35
50
50
50

Cross
section
screen,
mm
10
10
16
4
6
6
6
6
10
10
16
16
6
6
6
6
6
6
6
10
10
10
16
16
16
16
16
16
16
16
16
25
25
-

Conductor
type 2

STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC

Max.
conductor
resistance at
20C,
Ohm/km
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.7
7.56
4.7
4.7
4.7
4.7
4.7
4.7
3.11
3.11
3.11
3.11
3.11
3.11
1.84
1.84
1.84
1.84
1.84
1.84
1.16
1.16
1.16
1.16
1.16
1.16
0.734
0.734
0.734
0.734
0.734
0.734
0.529
0.529
0.529
0.529
0.529
0.391
0.391
0.391

Max.
conductor
resistance at
90C,
Ohm/km
15.6
15.6
15.6
15.6
15.6
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
9.64
5.99
9.64
5.99
5.99
5.99
5.99
5.99
5.99
3.97
3.97
3.97
3.97
3.97
3.97
2.35
2.35
2.35
2.35
2.35
2.35
1.48
1.48
1.48
1.48
1.48
1.48
0.936
0.936
0.936
0.936
0.936
0.936
0.675
0.675
0.675
0.675
0.675
0.499
0.499
0.499

Reactance
at 50Hz,
Ohm/km

0.110
0.110
0.110
0.110
0.110
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.103
0.096
0.103
0.096
0.096
0.096
0.096
0.096
0.096
0.090
0.090
0.090
0.090
0.090
0.090
0.084
0.084
0.084
0.084
0.084
0.084
0.080
0.080
0.080
0.080
0.080
0.080
0.079
0.079
0.079
0.079
0.079
0.079
0.076
0.076
0.076
0.076
0.076
0.076
0.076
0.076

www.drakaMOG.com
257

Reactance
at 60Hz,
Ohm/km

0.132
0.132
0.132
0.132
0.132
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.115
0.123
0.115
0.115
0.115
0.115
0.115
0.115
0.108
0.108
0.108
0.108
0.108
0.108
0.101
0.101
0.101
0.101
0.101
0.101
0.096
0.096
0.096
0.096
0.096
0.096
0.095
0.095
0.095
0.095
0.095
0.095
0.092
0.092
0.092
0.092
0.092
0.092
0.092
0.092

Current
rating IEC
60092-352
Table B.4,
Ampere
8.5
7.5
7
16
12.5
26
26
21
21
21
21
17.5
15.5
13
11
10
9
28
16.5
34
28
28
23.5
34
28
44
36
36
36
44
36
61
50
50
61
50
50
80
67
67
67
67
80
108
89
89
89
108
89
133
110
110
110
110
137
137
137

Short
circuit
rating 1
second,
Ampere
210
210
210
210
210
350
350
350
350
350
350
350
350
350
350
350
350
560
350
560
560
560
560
560
560
840
840
840
840
840
840
1400
1400
1400
1400
1400
1400
2240
2240
2240
2240
2240
2240
3500
3500
3500
3500
3500
3500
4900
4900
4900
4900
4900
7000
7000
7000

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 8 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Number
of
elements

5G
2
3
4
4G
5G
5
2
3
4
4G
5G
2
3
4
4G
4G
4G
4G
4
4

Cross
section
core,
mm
50
70
70
70
70
70
70
95
95
95
95
120
120
120
120
120
150
185
240
185
240

Cross
section
screen,
mm
35
35
35
35
50
50
50
60
60
60
95
120

Conductor
type 2

STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC

Max.
conductor
resistance at
20C,
Ohm/km
0.391
0.27
0.27
0.27
0.27
0.27
0.27
0.195
0.195
0.195
0.195
0.154
0.154
0.154
0.154
0.154
0.126
0.1
0.0762
0.1
0.0762

Max.
conductor
resistance at
90C,
Ohm/km
0.499
0.344
0.344
0.344
0.344
0.344
0.344
0.249
0.249
0.249
0.249
0.196
0.196
0.196
0.196
0.196
0.161
0.128
0.0972
0.1275
0.0972

Reactance
at 50Hz,
Ohm/km

0.076
0.074
0.074
0.074
0.074
0.074
0.074
0.073
0.073
0.073
0.073
0.072
0.072
0.072
0.072
0.072
0.072
0.072
0.080
0.081
0.080

Reactance
at 60Hz,
Ohm/km

0.092
0.088
0.088
0.088
0.088
0.088
0.088
0.088
0.088
0.088
0.088
0.086
0.086
0.086
0.086
0.086
0.087
0.086
0.095
0.098
0.095

Current
rating IEC
60092-352
Table B.4,
Ampere
137
206
169
169
169
169
141.5
249
205
205
205
237
288
237
237
237
272
311
365
311
365

Short
circuit
rating 1
second,
Ampere
7000
9800
9800
9800
9800
9800
9800
13300
13300
13300
13300
16800
16800
16800
16800
16800
21000
25900
33600
25900
33600

Ambient temperature correction factors


Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
258

Minimum Installation
Temperature
-20C

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 9 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Flame retardant halogen-free
power cable. Mud resistant.
Single core cable.

RFOU 0,6/1kV
EPR/EPR/TCWB/EVA
NEK 606 CodeP1/P8

Operating temperature
Operating Voltage

: 90C
: 0,6/1kV

Standards applied
Application

IEC 60092-353/60502-1 - Design


IEC 60228 class 2
- Conductor
Fixed installation for power,control and lighting in both EX- and safe IEC 60092-351
- Insulation
areas, general purposes. For installation in areas exposed to MUD IEC 60092-359
- Sheath
and drilling/cleaning fluids. Meets the MUD resistance requirement IEC 60332-1
- Flame Retardant
in NEK 606.
- Flame Retardant
IEC 60332-3-22
- Halogen Free
IEC 60754-1,2
IEC 61034-1,2
- Low Smoke

Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour

R
F

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


EP-rubber, IEC 60092-351 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoset compound
PET tape

Tinned annealed copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound,


SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 1 x 500/25 mm2 IEC
60332-3-22
DRAKA 01 = Draka Norsk Kabel,
Black

www.drakaMOG.com
259

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 10 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross
Number
Conductor Insulation
section section
of
Diameter, Thickness,
core,
screen,
elements
mm
mm
mm
mm

Thickness
Inner
covering,
mm

400

25

26.00

2.4

1.4

500

25

29.0

2.4

1.4

630

25

32.80

2.4

1.4

Diameter
inner
covering,
mm
34.5
1.5
37.5
1.5
41.5 2

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

Diameter
outer
sheath,
mm

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

0.4

2.1

40.5 2

5060

3936

0.4

2.2

44 2

6190

4894

0.4

2.3

48 2

7620

6167

Ordering information
Part number
800011
800012
800013

Description
RFOU 0.6/1kV 1X 400/25 P1/P8
RFOU 0.6/1kV 1X 500/25 P1/P8
RFOU 0.6/1kV 1X 630/25 P1/P8

Sheath Colour
BLACK
BLACK
BLACK

Stock item
-

EAN No. DNK


7021528000115
7021528000122
7021528000139

EL No.
-

Electrical values power cables


Number
of
elements

Cross
section
core,
mm

Cross
section
screen,
mm

Conductor
type 2

Max.
Max.
conductor
conductor
resistance at resistance at
20C,
90C,
Ohm/km
Ohm/km

Reactance
at 50Hz,
Ohm/km

Reactance
at 60Hz,
Ohm/km

400

25

STCC

0.0475

0.0606

0.087

0.104

500

25

STCC

0.0369

0.0471

0.085

0.103

630

25

STCC

0.0286

0.0365

0.083

0.100

Current
Short
rating IEC
circuit
60092-352
rating 1
Table B.4,
second,
Ampere
Ampere
690 dc / 670
56000
ac
780 dc / 720
70000
ac
890 dc / 780
88200
ac

Ambient temperature correction factors


Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
260

Minimum Installation
Temperature
-20C

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 11 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Flame retardant halogen-free
power cable. Mud resistant.
Double braided.

RFOU 0,6/1kV
EPR/EPR/TCWB/EVA
NEK 606 CodeP1/P8

Operating temperature
Operating Voltage

: 90C
: 0,6/1kV

Standards applied
Application

IEC 60092-353
IEC 60228 class 2
Fixed installation for power,control and lighting in both EX- and safe IEC 60092-351
areas, general purposes. For installation in areas exposed to MUD IEC 60092-359
and drilling/cleaning fluids. Meets the MUD resistance requirement IEC 60332-1
in NEK 606.
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing unit
Outer sheath colour

R
F

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


EP-rubber, IEC 60092-351 (EPR)
Cores laid up in concentric layers
Flame retardant and halogen-free thermoset compound
PET tape + rubberized Polyamide tape

Two layers of tinned copper wire braid (double braid)


PET tape + rubberized Polyamide tape

Flame retardant, halogen-free and mud resistant thermoset compound,


SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA 01 RFOU 0,6/1kV P1/P8 3 x 185/95 mm2 IEC
60332-3-22 ETL Classified No. 3067229
DRAKA 01 = Draka Norsk Kabel,
Black

www.drakaMOG.com
261

RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 12 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross
Number
Conductor Insulation
section section
of
Diameter, Thickness,
core,
screen,
elements
mm
mm
mm
mm

Thickness
Inner
covering,
mm

185

95

17.70

2.0

1.6

150

70

15.9

1.8

1.6

150

70

15.9

1.8

240

120

20.15

2.2

1.8

Diameter
inner
covering,
mm
50.5
2.5
45.5 2
51.5
2.5
57.5
2.5

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

2.6

Diameter
outer
sheath,
mm
59.5
2.5
54 2.5

0.5

2.7

0.4

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

9220

6278

7390

4904

0.4

2.8

60.5 3

9320

6288

0.6

68 3

11820

8063

Ordering information
Part number
800093
800102
800109
800112

Description
RFOU 0.6/1kV 3X 185/95 P1/P8
RFOU 0.6/1kV 3X 150/70 P1/P8
RFOU 0.6/1kV 4X 150/70 P1/P8
RFOU 0.6/1kV 3X 240/120 P1/P8

Sheath Colour
BLACK
BLACK
BLACK
BLACK

Stock item

EAN No. DNK


7021528000931
7021528001020
7021528001099
7021528001129

EL No.
1044252
-

Electrical values power cables


Number
of
elements

3
3
4
3

Cross
section
core,
mm
185
150
150
240

Cross
section
screen,
mm
95
70
70
120

Conductor
type 2

STCC
STCC
STCC
STCC

Max.
conductor
resistance at
20C,
Ohm/km
0.1
0.126
0.126
0.0762

Max.
conductor
resistance at
90C,
Ohm/km
0.128
0.161
0.161
0.0972

Reactance
at 50Hz,
Ohm/km

0.072
0.072
0.072
0.072

Reactance
at 60Hz,
Ohm/km

0.086
0.087
0.087
0.086

Current
rating IEC
60092-352
Table B.4,
Ampere
311
272
272
365

Short
circuit
rating 1
second,
Ampere
25900
21000
21000
33600

Ambient temperature correction factors


Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
262

Minimum Installation
Temperature
-20C

RFOU 6_10_12kV(3).doc
29.12.2006 11:06
Page 1 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable


Flame retardant halogen-free medium
voltage (MV) cable. Mud resistant

RFOU 6/10(12) kV
EPR/EPR/TCWB/EVA
NEK 606 CodeP3/P10

Operating temperature
Operating Voltage

: 90C
: 6/10(12) kV

Standards applied

Application
Fixed installation for medium voltage (MV) power in both EXand safe areas, general purposes. For installation in areas
exposed to MUD and drilling/cleaning fluids.

IEC 60092-354
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 600754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Conductor screen
semiconductive
Insulation
Insulation screen
semicoductive

Tinned stranded and compressed copper (STCC), IEC 60228 class 2


Semiconductive layer (EP-rubber)
R

Lay up / Shielding
Inner covering
Tape over inner covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Outer sheath colour

EP-rubber, IEC 60092-351 (EPR)


Semiconductive layer (EP-rubber)
Cores are laid up together. Cores are identified by White, Black or Red
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoset compound
PET tape

Tinned annealed copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound,


SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA NORSK KABEL RFOU 6/10(12)KV P3/P10 3
x 95/50 mm2 IEC 60332-3-22
Red

www.drakaMOG.com
263

RFOU 6_10_12kV(3).doc
29.12.2006 11:06
Page 2 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable


Range and dimensions
Cross Cross
Number
Conductor Insulation
section section
of
Diameter, Thickness,
core,
screen,
elements
mm
mm
mm
mm

Thickness
Inner
covering,
mm

Diameter
inner
covering,
mm

16

11

5.2

3.4

1.0

18.5 1.0 0.3

1.6

25

11

6.5

3.4

1.0

20,0 1.0 0.3

1.7

35

11

7.4

3.4

1.0

50

11

8.8

3.4

1.0

70

16

10.3

3.4

95

16

12.1

120

20

150

21.0
1.5
22.0
1.0

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

0.3

1.7

0.3

1.9

1.0

23.5 1.5 0.3

1.9

3.4

1.2

25.5 1.5 0.3

2.0

13.6

3.4

1.2

27.5
1.5

0.3

2.0

19

15.1

3.4

1.2

28.5 1.5 0.3

2.0

185

18

16.8

3.4

1.2

30.5 1.5 0.3

2.1

240

21

19.1

3.4

1.2

33.0
1.5

0.3

2.1

300

29

21.5

3.4

1.2

35 1.5

0.3

2.2

400

35

24.5

3.4

1.2

36 1.5

0.4

2.3

500

40

27.5

3.4

1.4

0.4

2.5

630

40

32.3

3.4

1.4

0.4

2.7

16

32

5.2

3.4

1.4

0.4

2.4

25

31

6.5

3.4

1.4

0.4

2.4

35

35

7.4

3.4

1.4

0.4

50

31

8.8

3.4

1.6

70

35

10.3

3.4

1.6

95

50

12.1

3.4

1.6

120

60

13.6

3.4

1.6

150

75

15.1

3.4

1.6

185

45

16.8

3.4

1.6

240

53

19.1

3.4

1.6

300

55

21.5

3.4

1.6

41.5
2.0
46.5
2.0
39.0
1.5
42.0
1.5
43.5
2.0
47.0
2.0
50.0
2.0
54.0
2.0
57.5
2.0
60 2
64.5
2.5
69.5
2.5
74.5
3.0

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

900

420

1100

516

26.0 1.5 1200

611

28.0
1.5
30.0
2.0
32.0
2.0
34.0
2.0
35.0
2.0
36.5
2.0

1450

780

1700

971

2100

1251

2350

1506

2600

1793

3100

2138

39.0 2.0 3800

2702

41.5
2.5
45.5
2.5
49.5
2.5
54.5
3.0
46.0
2.5
49.5
2.5

4600

3395

5900

4536

7350

5782

8750

7016

3300

1145

3800

1465

2.5

51.5 3.0 4300

1573

0.4

2.8

55 3

5000

2124

0.4

2.8

58.5 3

6000

2880

0.4

2.8

62.5 3.0 7500

3975

0.5

0.6

3.2

0.5

3.3

0.5
0.5

www.drakaMOG.com
264

Diameter
outer
sheath,
mm
24.0
1,5
25.0
1,5

66.5
3.0
70.5 3
74.0
3.5

8350

4650

9800

5634

11300

6511

3.5

79.5 3.5 13300

8609

3.7

85.0 4.0 16300

10725

RFOU 6_10_12kV(3).doc
29.12.2006 11:06
Page 3 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable


Ordering information
Part number
804000
804001
804002
804003
804004
804005
804006
804007
804008
804009
804010
804011
804012
804013
804020
804021
804022
804023
804024
804025
804026
804027
804028
804029
804030

Description
RFOU 6/10KV 1X 16/11mm P3/P
RFOU 6/10KV 1X 25/11mm P3/P
RFOU 6/10KV 1X 35/11mm P3/P
RFOU 6/10KV 1X 50/11mm P3/P
RFOU 6/10KV 1X 70/16mm P3/P
RFOU 6/10KV 1X 95/16mm P3/P
RFOU 6/10KV 1X 120/20mm P3/
RFOU 6/10KV 1X 150/19mm P3/
RFOU 6/10KV 1X185/18mm P3/P10
RFOU 6/10KV 1X 240/21mm P3/
RFOU 6/10KV 1X 300/29mm P3/
RFOU 6/10KV 1X 400/35mm P3/
RFOU 6/10KV 1X 500/40mm P3/
RFOU 6/10KV 1X 630/40mm P3/
RFOU 6/10KV 3X 16/32mm P3/P
RFOU 6/10KV 3X 25/31mm P3/P
RFOU 6/10KV 3X 35/35mm P3/P
RFOU 6/10KV 3X 50/31mm P3/P
RFOU 6/10KV 3X 70/35mm P3/P
RFOU 6/10KV 3X 95/50mm P3/P
RFOU 6/10KV 3X 120/60mm P3/
RFOU 6/10KV 3X 150/75mm P3/
RFOU 6/10KV 3X 185/45mm P3/
RFOU 6/10KV 3X 240/53mm P3/
RFOU 6/10KV 3X 300/55mm P3/

Sheath Colour
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED
RED

Stock item
-

EAN No. DNK


7021528040005
7021528040012
7021528040029
7021528040036
7021528040043
7021528040050
7021528040067
7021528040074
7021528040081
7021528040098
7021528040104
7021528040111
7021528040128
7021528040135
7021528040203
7021528040210
7021528040227
7021528040234
7021528040241
7021528040258
7021528040265
7021528040272
7021528040289
7021528040296
7021528040302

EL No.
-

Electrical values power cables


Number Cross Cross Conductor
Max.
of
section section
type 2
conductor
elements core, screen,
resistance
mm
mm
at 20C,
Ohm/km

Max.
conductor
resistance
at 90C,
Ohm/km

Reactance Reactance Capacitans


at 50Hz,
at 60Hz, per phase,
Ohm/km
Ohm/km
nF/km

1
1
1
1
1
1
1
1
1
1
1

16
25
35
50
70
95
120
150
185
240
300

11
11
11
11
16
16
20
19
18
21
29

STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC

1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774

0.154
0.144
0.138
0.132
0.125
0.119
0.116
0.111
0.108
0.104
0.104

0.185
0.173
0.166
0.158
0.150
0.142
0.139
0.133
0.130
0.125
0.124

220
250
270
300
340
380
410
450
480
540
590

400

35

STCC

0.0475

0.0606

0.090

0.118

660

500

40

STCC

0.0369

0.0471

0.097

0.117

720

630

40

STCC

0.0286

0.0365

0.092

0.110

840

www.drakaMOG.com
265

Current
rating
IEC
60092352
Table
B.4,
Ampere
96
127
157
196
242
293
339
389
444
522
601
690 dc /
670 ac
780 dc /
720 ac
890 dc /
780 ac

Short
circuit
rating 1
second,
Ampere

2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000
56000
70000
88200

RFOU 6_10_12kV(3).doc
29.12.2006 11:06
Page 4 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable


Number Cross Cross Conductor
Max.
of
section section
type 2
conductor
elements core, screen,
resistance
mm
mm
at 20C,
Ohm/km

3
3
3
3
3
3
3
3
3
3
3

16
25
35
50
70
95
120
150
185
240
300

32
31
35
31
35
50
60
75
45
53
55

STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC
STCC

1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607

Max.
conductor
resistance
at 90C,
Ohm/km

1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774

Reactance Reactance Capacitans


at 50Hz,
at 60Hz, per phase,
Ohm/km
Ohm/km
nF/km

0.119
0.119
0.114
0.108
0.103
0.098
0.095
0.092
0.092
0.087
0.084

0.143
0.143
0.137
0.130
0.124
0.118
0.114
0.111
0.111
0.104
0.101

220
250
270
300
340
380
410
450
480
540
590

Current
rating
IEC
60092352
Table
B.4,
Ampere
67
89
110
137
169
205
237
272
311
365
421

Short
circuit
rating 1
second,
Ampere

2240
3500
4900
7000
9800
13300
16800
21000
25900
33600
42000

Ambient temperature correction factors


Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
15 x D

Minimum Bending Radius


Fixed Installed
9xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
266

Minimum Installation
Temperature
-20C

RFOU(C) 250V(3).doc
03/06/2008 15:29:00
Page 1 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable


Flame retardant halogen-free
instrumentation cable. Mud resistant

RFOU(c) 250V
EPR/EPR/TCWB/EVA
NEK 606 CodeS2/S6

Operating temperature
Operating Voltage

: 90C
: 250V

Standards applied
Application
Fixed installation for instrumentation, communication, Control
and alarm systems in both EX- and safe areas. Meets the mud
resistant requirements in NEK 606.

IEC 60092-376 (2003-05)


IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 600754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation

Pair / Triple /
Quad twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire. Pairs/triples are identified by numbers printed directly on the
insulated conductors.
Flame retardant and halogen-free thermoset compound
PET tape

Tinned annealed copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-359)
E.g. "meter" "year" DRAKA 01 RFOU(c) 250V S2/S6 8 PAIR 0,75 mm2 IEC
60092-376 IEC 60332-3-22 ETL Classified No. 3067229
DRAKA 01 = Draka Norsk Kabel,
Grey or Blue

www.drakaMOG.com
267

RFOU(C) 250V(3).doc
03/06/2008 15:29:00
Page 2 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable


Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey
Range and dimensions
Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm
2
2
0.75
1.1
0.6
2
2
0.75
1.1
0.6

Thickness
Inner
covering,
mm
1.1
1.1

1.4
1.6
1.6

Diameter
inner
covering,
mm
10 0.8
10 0.8
11.5
0.8
11.5
0.8
15 0.8
15 0.8
18 0.8
18 0.8
19.5
0.8
19.5
0.8
20.5 1
24 1
24 1

0.75

1.1

0.6

1.1

0.75

1.1

0.6

1.1

8
8
12
12

2
2
2
2

0.75
0.75
0.75
0.75

1.1
1.1
1.1
1.1

0.6
0.6
0.6
0.6

1.1
1.1
1.3
1.3

16

0.75

1.1

0.6

1.4

16

0.75

1.1

0.6

1.4

19
24
24

2
2
2

0.75
0.75
0.75

1.1
1.1
1.1

0.6
0.6
0.6

0.75

1.1

0.75

Diameter
Braid
Wire,
mm
0.2
0.2

Thickness
Outer
Sheath,
mm
1.2
1.2

Diameter
outer
sheath,
mm
13 0.8
13 0.8

Weight
of Cable
Approx.
(Kg/Km)
275
275

Copper
content
Approx.
(kg/km)
82
82

0.3

1.3

15 0.8

390

139

0.3

1.3

15 0.8

390

139

0.3
0.3
0.3
0.3

1.4
1.4
1.5
1.5

19 0.8
19 0.8
22 1
22 1

600
600
790
790

223
223
291
291

0.3

1.6

23.5 1

950

359

0.3

1.6

23.5 1

950

359

0.3
0.3
0.3

1.7
1.8
1.8

1090
1350
1350

422
511
511

0.6

1.1

11 0.8

0.3

1.3

360

127

1.1

0.6

1.1

11 0.8

0.3

1.3

360

127

0.75

1.1

0.6

1.1

0.3

1.3

470

182

0.75

1.1

0.6

1.1

470

182

8
8
12
12
16
24
24

3
3
3
3
3
3
3

0.75
0.75
0.75
0.75
0.75
0.75
0.75

1.1
1.1
1.1
1.1
1.1
1.1
1.1

0.6
0.6
0.6
0.6
0.6
0.6
0.6

760
740
990
990
1220
1790
1790

292
292
386
386
488
692
692

1.5

1.6

410

162

1.5

4
4
5

2
2
2

1.5
1.5
1.5

410

162

560
560
640

235
235
263

0.3

1.3

1.1
1.1
1.3
1.3
1.4
1.8
1.8

12.5
0.8
12.5
0.8
17 0.8
17 0.8
20 1
20 1
21.5 1
27 1
27 1

0.3
0.3
0.3
0.3
0.3
0.3
0.3

1.5
1.5
1.6
1.6
1.7
2
2

0.7

1.1

12 0.8

0.3

1.3

1.6

0.7

1.1

12 0.8

0.3

1.3

1.6
1.6
1.6

0.7
0.7
0.7

1.1
1.1
1.1

0.3
0.3
0.3

1.4
1.4
1.4

1.5

1.6

0.7

1.1

0.3

1.6

23 1

890

379

1.5

1.6

0.7

1.1

0.3

1.6

23 1

890

379

10
10
12
16
16
19

2
2
2
2
2
2

1.5
1.5
1.5
1.5
1.5
1.5

1.6
1.6
1.6
1.6
1.6
1.6

0.7
0.7
0.7
0.7
0.7
0.7

1.2
1.2
1.3
1.4
1.4
1.4

14 0.8
14 0.8
15 0.8
18.5
0.8
18.5
0.8
21 1
21 1
22 1
24 1
24 1
25.5 1

25 1
28.5 1
28.5 1
14.5
0.8
14.5
0.8
16.5
0.8
16.5
0.8
21 1
21 1
24 1
24 1
26 1
32 1.5
32 1.5
15.5
0.8
15.5
0.8
18 0.8
18 0.8
19 0.8

0.3
0.3
0.3
0.3
0.3
0.3

1.7
1.7
1.7
1.8
1.8
1.9

1070
1070
1190
1480
1480
1640

460
460
515
652
652
736

24

1.5

1.6

0.7

1.8

30 1.5

0.3

2.1

25.5 1
25.5 1
26.5 1
28.5 1
28.5 1
30 1.5
35.5
1.5

2150

925

www.drakaMOG.com
268

RFOU(C) 250V(3).doc
03/06/2008 15:29:00
Page 3 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable


Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm
32
2
1.5
1.6
0.7
32
2
1.5
1.6
0.7
2
3
1.5
1.6
0.7

Thickness
Inner
covering,
mm
1.9
1.9
1.1

Diameter
Braid
Wire,
mm
0.4
0.4
0.3

Thickness
Outer
Sheath,
mm
2.2
2.2
1.4

0.3

1.4

1.1
1.3
1.3

Diameter
inner
covering,
mm
33 1.5
33 1.5
13 0.8
15.5
0.8
21 1
24.5 1
24.5 1

1.5

1.6

0.7

1.1

8
12
12

3
3
3

1.5
1.5
1.5

1.6
1.6
1.6

0.7
0.7
0.7

16

1.5

1.6

16

1.5

24

0.3
0.3
0.3

1.7
1.8
1.8

0.7

1.4

26.5 1

0.3

1.9

1.6

0.7

1.4

26.5 1

0.3

1.9

1.5

1.6

0.7

1.8

0.4

2.2

24

1.5

1.6

0.7

1.8

0.4

2.2

2.5

0.7

1.1

0.3

1.4

2.5

0.7

1.1

16 0.8

0.3

1.4

2.5

0.7

1.1

16 0.8

0.3

1.4

2.5

0.7

1.1

0.3

12

2.5

0.7

1.3

0.3

33.5
1.5
33.5
1.5
13.5
0.8

17.5
0.8
25 1

Diameter
outer
sheath,
mm
39 1.5
39 1.5
17 0.8
19.5
0.8
25.5 1
29 1
29 1
31.5
1.5
31.5
1.5
39.5
1.5
39.5
1.5
17.5
0.8
19.5
0.8
19.5
0.8

Weight
of Cable
Approx.
(Kg/Km)
2760
2760
490

Copper
content
Approx.
(kg/km)
1253
1253
191

670

291

1130
1550
1550

517
711
711

1930

904

1930

904

2920

1370

2920

1370

490

200

680

309

680

309

1.5

21.5 1

820

371

1.8

30 1.5

1560

758

Electrical values instrumentation cables


Capacitance, approx.
(nF/km)
Unshielded pair 0,75 mm
100
Unshielded triple 0,75 mm
100
Unshielded pair 1,5 mm
110
Unshielded triple 1,5 mm
110
Unshielded pair 2,5 mm
125
Unshielded triple 2,5 mm
125
Type

Inductance, approx,
(mH/km)
0,67
0,67
0,63
0,63
0,59
0,59

Resistance at 20C, max.


(Ohm/km)
26,3
26,3
12,2
12,2
7,56
7,56

L/R ratio,
(microH/Ohm)
12,7
12,7
26,6
26,6
39,0
39,0

Ordering information
Part number
892606
892607
892618
892619
892630
892631
892636
892637
892642
892643
892645
892648
892649

Description
RFOU(C) 2PAIR 0.75mm S2/S6
RFOU(C) 2PAIR 0.75mm S2/S6
RFOU(C) 4PAIR 0.75mm S2/S6
RFOU(C) 4PAIR 0.75mm S2/S6
RFOU(C) 8PAIR 0.75mm S2/S6
RFOU(C) 8PAIR 0.75mm S2/S6
RFOU(C) 12PAIR 0.75mm S2/S6
RFOU(C) 12PAIR 0.75mm S2/S6
RFOU(C) 16PAIR 0.75mm S2/S6
RFOU(C) 16PAIR 0.75mm S2/S6
RFOU(C) 19PAIR 0.75mm S2/S6
RFOU(C) 24PAIR 0.75mm S2/S6
RFOU(C) 24PAIR 0.75mm S2/S6

Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE

www.drakaMOG.com
269

Stock item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

EAN No. DNK


7021528926064
7021528926071
7021528926187
7021528926194
7021528926309
7021528926316
7021528926361
7021528926378
7021528926422
7021528926439
7021528926453
7021528926484
7021528926491

EL No.
1044421
1044422
1044423
1044424
1044428
1044429
1044430
1044431
1044433
1044432
1044434
1044438
1044437

RFOU(C) 250V(3).doc
03/06/2008 15:29:00
Page 4 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable


Part number
892666
892667
892678
892679
892690
892691
892696
892697
892702
892708
892709
892806
892807
892818
892819
892821
892830
892831
892834
892835
892836
892842
892843
892845
892848
892854
892855
892866
892878
892891
892896
892897
892902
892903
892908
892909
893006
893018
893019
893021
893036

Description
RFOU(C) 2TRIP 0.75mm S2/S6
RFOU(C) 2TRIP 0.75mm S2/S6
RFOU(C) 4TRIP 0.75mm S2/S6
RFOU(C) 4TRIP 0.75mm S2/S6
RFOU(C) 8TRIP 0.75mm S2/S6
RFOU(C) 8TRIP 0.75mm S2/S6
RFOU(C) 12TRIP 0.75mm S2/S6
RFOU(C) 12TRIP 0.75mm S2/S6
RFOU(C) 16TRIP 0.75mm S2/S6
RFOU(C) 24TRIP 0.75mm S2/S6
RFOU(C) 24TRIP 0.75mm S2/S6
RFOU(C) 2PAIR 1.5mm S2/S6
RFOU(C) 2PAIR 1.5mm S2/S6
RFOU(C) 4PAIR 1.5mm S2/S6
RFOU(C) 4PAIR 1.5mm S2/S6
RFOU(C) 5PAIR 1.5mm S2/S6
RFOU(C) 8PAIR 1.5mm S2/S6
RFOU(C) 8PAIR 1.5mm S2/S6
RFOU(C) 10PAIR 1.5mm S2/S6
RFOU(C) 10PAIR 1.5mm S2/S6
RFOU(C) 12PAIR 1.5mm S2/S6
RFOU(C) 16PAIR 1.5mm S2/S6
RFOU(C) 16PAIR 1.5mm S2/S6
RFOU(C) 19PAIR 1.5mm S2/S6
RFOU(C) 24PAIR 1.5mm S2/S6
RFOU(C) 32PAIR 1.5mm S2/S6
RFOU(C) 32PAIR 1.5mm S2/S6
RFOU(C) 2TRIP 1.5mm S2/S6
RFOU(C) 4TRIP 1.5mm S2/S6
RFOU(C) 8TRIP 1.5mm S2/S6
RFOU(C) 12TRIP 1.5mm S2/S6
RFOU(C) 12TRIP 1.5mm S2/S6
RFOU(C) 16TRIP 1.5mm S2/S6
RFOU(C) 16TRIP 1.5mm S2/S6
RFOU(C) 24TRIP 1.5mm S2/S6
RFOU(C) 24TRIP 1.5mm S2/S6
RFOU(C) 2PAIR 2.5mm S2/S6
RFOU(C) 4PAIR 2.5mm S2/S6
RFOU(C) 4PAIR 2.5mm S2/S6
RFOU(C) 5PAIR 2.5mm S2/S6
RFOU(C) 12PAIR 2.5mm S2/S6

Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
GREY
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
GREY

Stock item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-

EAN No. DNK


7021528926668
7021528926675
7021528926781
7021528926798
7021528926903
7021528926910
7021528926965
7021528926972
7021528927023
7021528927085
7021528927092
7021528928068
7021528928075
7021528928181
7021528928198
7021528928211
7021528928303
7021528928310
7021528928341
7021528928358
7021528928365
7021528928426
7021528928433
7021528928457
7021528928488
7021528928549
7021528928556
7021528928662
7021528928785
7021528928914
7021528928969
7021528928976
7021528929027
7021528929034
7021528929089
7021528929096
7021528930061
7021528930184
7021528930191
7021528930214
7021528930368

EL No.
1044490
1044491
1044492
1044493
1044496
1044497
1044499
1044500
1044501
1044507
1044508
1044461
1044462
1044463
1044464
1044468
1044469
1044470
1044472
1044473
1044474
1044478
1044561
1044563
1044568
1044569
1044570
1044571
1044572
1044577
1044578
-

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
270

Minimum Installation
Temperature
-20C

RFOU(I) 250V(3).doc
03/06/2008 10:46:00
Page 1 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable


Flame retardant halogen-free
instrumentation cable. Mud
resistant

RFOU(i) 250V
EPR/EPR/TCWB/EVA
NEK 606 CodeS1/S5

Operating temperature
Operating Voltage

: 90C
: 250V

Standards applied
Application
Fixed installation for instrumentation, communication, Control
and alarm systems in both EX- and safe areas. Meets the mud
resistant requirements in NEK 606.

IEC 60092-376 (2003-05)


IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 600754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation

Pair / Triple /
Quad twisting
Lay up /
Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Manufacturing
unit
Outer sheath
colour

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbers printed directly on the insulated conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and
wrapped with a PETP tape.
Flame retardant and halogen-free thermoset compound
PET tape

Tinned annealed copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-359)
E.g. "meter" "year" DRAKA 01 RFOU(i) 250V S1/S5 4 PAIR 0,75 mm2 IEC 60092376 IEC 60332-3-22 ETL Classified No. 3067229
DRAKA 01 = Draka Norsk Kabel,
Grey or Blue

www.drakaMOG.com
271

RFOU(I) 250V(3).doc
03/06/2008 10:46:00
Page 2 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable


Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey

Range and dimensions


Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm
1
2
0.75
1.1
0.6
1
2
0.75
1.1
0.6
2
2
0.75
1.1
0.6
2
2
0.75
1.1
0.6

Thickness
Inner
covering,
mm
1.1
1.1
1.1
1.1

12

0.75

1.1

0.6

1.3

16
16
19
19

2
2
2
2

0.75
0.75
0.75
0.75

1.1
1.1
1.1
1.1

0.6
0.6
0.6
0.6

1.4
1.4
1.4
1.4

Diameter
inner
covering,
mm
7 0.5
7 0.5
10 0.8
10 0.8
11.5
0.8
11.5
0.8
15.5
0.8
15.5
0.8
18.5
0.8
18.5
0.8
20.5 1
20.5 1
21.5 1
21.5 1

0.75

1.1

0.6

1.1

0.75

1.1

0.6

1.1

0.75

1.1

0.6

1.1

0.75

1.1

0.6

1.1

12

0.75

1.1

0.6

1.3

Diameter
Braid
Wire,
mm
0.2
0.2
0.2
0.2

Thickness
Outer
Sheath,
mm
1.1
1.1
1.2
1.2

Diameter
outer
sheath,
mm
10 0.8
10 0.8
13 0.8
13 0.8

Weight
of Cable
Approx.
(Kg/Km)
185
185
280
280

Copper
content
Approx.
(kg/km)
55
55
87
87

0.3

1.3

15 0.8

430

169

0.3

1.3

15 0.8

430

169

0.3

1.5

690

271

0.3

1.5

690

271

0.3

1.6

930

356

24

0.75

1.1

0.6

1.6

25.5 1

0.3

1.9

24

0.75

1.1

0.6

1.6

25.5 1

0.3

1.9

0.75

1.1

0.6

1.1

7 0.5

0.2

1.1

0.75

1.1

0.6

1.1

7 0.5

0.2

1.1

0.75

1.1

0.6

1.1

11 0.8

0.3

1.3

0.75

1.1

0.6

1.1

11 0.8

0.3

1.3

0.75

1.1

0.6

1.1

0.3

1.4

0.75

1.1

0.6

1.1

8
8
12
12
16
16
19

3
3
3
3
3
3
3

0.75
0.75
0.75
0.75
0.75
0.75
0.75

1.1
1.1
1.1
1.1
1.1
1.1
1.1

0.6
0.6
0.6
0.6
0.6
0.6
0.6

24

0.75

1.1

24

0.75

1
1

2
2

22.5 1

0.3

1.6

22.5 1

930

356

0.3
0.3
0.3
0.3

1.7
1.7
1.7
1.7

25 1
25 1
26 1
26 1
30.5
1.5
30.5
1.5
10.5
0.8
10.5
0.8
14.5
0.8
14.5
0.8
16.5
0.8
16.5
0.8
21.5 1
21.5 1
25 1
25 1
28 1
28 1
29 1
34.5
1.5
34.5
1.5
11 0.8
11 0.8
15.5
0.8

1160
1160
1280
1280

449
449
501
501

1630

612

1630

612

200

61

200

61

380

148

380

148

530

211

530

211

840
840
1150
1150
1440
1440
1600

339
339
459
459
579
579
650

2110

818

2110

818

230
230

72
72

420

169

0.3

1.4

1.1
1.1
1.3
1.3
1.4
1.4
1.4

12.5
0.8
12.5
0.8
17 0.8
17 0.8
20.5 1
20.5 1
23 1
23 1
24 1

0.3
0.3
0.3
0.3
0.3
0.3
0.3

1.6
1.6
1.7
1.7
1.8
1.8
1.8

0.6

1.8

29 1

0.3

1.1

0.6

1.8

29 1

0.3

1.5
1.5

1.6
1.6

0.7
0.7

1.1
1.1

8 0.5
8 0.5

0.2
0.2

1.1
1.1

1.5

1.6

0.7

1.1

12 0.8

0.3

1.3

www.drakaMOG.com
272

19.5
0.8
19.5
0.8

RFOU(I) 250V(3).doc
03/06/2008 10:46:00
Page 3 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable


Cross
Number No of
Conductor Insulation
section
of
cores in
Diameter, Thickness,
core,
elements element
mm
mm
mm

Thickness
Inner
covering,
mm

Diameter
inner
covering,
mm

Diameter
Braid
Wire,
mm

Thickness
Outer
Sheath,
mm

1.5

1.6

0.7

1.1

12 0.8

0.3

1.3

4
4
8
8
12
12

2
2
2
2
2
2

1.5
1.5
1.5
1.5
1.5
1.5

1.6
1.6
1.6
1.6
1.6
1.6

0.7
0.7
0.7
0.7
0.7
0.7

1.1
1.1
1.1
1.1
1.3
1.3

14 0.8
14 0.8
19 0.8
19 0.8
23 1
23 1

0.3
0.3
0.3
0.3
0.3
0.3

1.4
1.4
1.6
1.6
1.8
1.8

16

1.5

1.6

0.7

1.4

25.5 1

0.3

1.9

16

1.5

1.6

0.7

1.4

25.5 1

0.3

1.9

19

1.5

1.6

0.7

1.4

26.5 1

0.3

1.9

19

1.5

1.6

0.7

1.4

26.5 1

0.3

1.9

24
24

2
2

1.5
1.5

1.6
1.6

0.7
0.7

1.8
1.8

0.4
0.4

2.2
2.2

32

1.5

1.6

0.7

1.9

0.4

2.3

32

1.5

1.6

0.7

1.9

32 1.5
32 1.5
35.5
1.5
35.5
1.5

Diameter
outer
sheath,
mm
15.5
0.8
18 0.8
18 0.8
23.5 1
23.5 1
27.5 1
27.5 1
30.5
1.5
30.5
1.5
31.5
1.5
31.5
1.5
38 1.5
38 1.5

Weight
of Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

420

169

600
600
990
990
1370
1370

254
254
425
425
588
588

1730

750

1730

750

1940

878

1940

878

2670
2670

1180
1180

42 2

3320

1500

0.4

2.3

42 2

3320

1500

1.5

1.6

0.7

1.1

8.5 0.5 0.2

1.1

265

93

1.5

1.6

0.7

1.1

8.5 0.5 0.2

1.1

265

93

1.5

1.6

0.7

1.1

1.5

1.6

0.7

1.1

1.5

1.6

0.7

1.1

8
8

3
3

1.5
1.5

1.6
1.6

0.7
0.7

1.1
1.1

13.5
0.8
15.5
0.8
15.5
0.8
21.5 1
21.5 1

520

214

740

328

12

1.5

1.6

0.7

1.3

12

1.5

1.6

0.7

16

1.5

1.6

16

1.5

24

24
1

11.5
0.8
11.5
0.8
17.5
0.8

0.3

1.4

0.3

1.5

20 1

0.3

1.5

20 1

740

328

0.3
0.3

1.7
1.7

1240
1240

563
563

26 1

0.3

1.9

1730

783

1.3

26 1

0.3

1.9

1730

783

0.7

1.6

29.5 1

0.3

2260

1002

1.6

0.7

1.6

29.5 1

0.3

26 1
26 1
30.5
1.5
30.5
1.5
34.5
1.5
34.5
1.5

2260

1002

1.5

1.6

0.7

1.8

0.4

2.3

42.5 2

3380

1566

1.5

1.6

0.7

1.8

0.4

2.3

42.5 2

3380

1566

2.5

0.7

1.1

0.2

1.1

12 0.8
17.5
0.8
20 1

280

99

2.5

0.7

1.1

2.5

0.7

1.1

36.5
1.5
36.5
1.5
9 0.5
13.5
0.8
16 0.8

0.3

1.4

0.3

1.5

www.drakaMOG.com
273

530

225

770

350

RFOU(I) 250V(3).doc
03/06/2008 10:46:00
Page 4 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable


Electrical values instrumentation cables
Type
Shielded pair 0,75 mm
Shielded triple 0,75 mm
Shielded pair 1,5 mm
Shielded triple 1,5 mm
Shielded pair 2,5 mm
Shielded triple 2,5 mm

Capacitance,
approx. (nF/km)
110
110
125
125
145
145

Inductance,
approx, (mH/km)
0,67
0,67
0,63
0,63
0,59
0,59

Resistance at 20C,
max. (Ohm/km)
26,3
26,3
12,2
12,2
7,56
7,56

L/R ratio,
(microH/Ohm)
12,7
12,7
26,6
26,6
39,0
39,0

Ordering information
Part number
892000
892001
892006
892007
892018
892019
892030
892031
892036
892037
892042
892043
892045
892046
892048
892049
892060
892061
892066
892067
892078
892079
892090
892091
892096
892097
892102
892103
892106
892108
892109
892200
892201
892206
892207
892218
892219
892230
892231
892236
892237
892242
892243
892245
892246
892248
892249

Description
RFOU(I) 1PAIR 0.75mm S1/S5
RFOU(I) 1PAIR 0.75mm S1/S5
RFOU(I) 2PAIR 0.75mm S1/S5
RFOU(I) 2PAIR 0.75mm S1/S5
RFOU(I) 4PAIR 0.75mm S1/S5
RFOU(I) 4PAIR 0.75mm S1/S5
RFOU(I) 8PAIR 0.75mm S1/S5
RFOU(I) 8PAIR 0.75mm S1/S5
RFOU(I) 12PAIR 0.75mm S1/S5
RFOU(I) 12PAIR 0.75mm S1/S5
RFOU(I) 16PAIR 0.75mm S1/S5
RFOU(I) 16PAIR 0.75mm S1/S5
RFOU(I) 19PAIR 0.75mm S1/S5
RFOU(I) 19PAIR 0.75mm S1/S5
RFOU(I) 24PAIR 0.75mm S1/S5
RFOU(I) 24PAIR 0.75mm S1/S5
RFOU(I) 1TRIP 0.75mm S1/S5
RFOU(I) 1TRIP 0.75mm S1/S5
RFOU(I) 2TRIP 0.75mm S1/S5
RFOU(I) 2TRIP 0.75mm S1/S5
RFOU(I) 4TRIP 0.75mm S1/S5
RFOU(I) 4TRIP 0.75mm S1/S5
RFOU(I) 8TRIP 0.75mm S1/S5
RFOU(I) 8TRIP 0.75mm S1/S5
RFOU(I) 12TRIP 0.75mm S1/S5
RFOU(I) 12TRIP 0.75mm S1/S5
RFOU(I) 16TRIP 0.75mm S1/S5
RFOU(I) 16TRIP 0.75mm S1/S5
RFOU(I) 19TRIP 0.75mm S1/S5
RFOU(I) 24TRIP 0.75mm S1/S5
RFOU(I) 24TRIP 0.75mm S1/S5
RFOU(I) 1PAIR 1.5mm S1/S5
RFOU(I) 1PAIR 1.5mm S1/S5
RFOU(I) 2PAIR 1.5mm S1/S5
RFOU(I) 2PAIR 1.5mm S1/S5
RFOU(I) 4PAIR 1.5mm S1/S5
RFOU(I) 4PAIR 1.5mm S1/S5
RFOU(I) 8PAIR 1.5mm S1/S5
RFOU(I) 8PAIR 1.5mm S1/S5
RFOU(I) 12PAIR 1.5mm S1/S5
RFOU(I) 12PAIR 1.5mm S1/S5
RFOU(I) 16PAIR 1.5mm S1/S5
RFOU(I) 16PAIR 1.5mm S1/S5
RFOU(I) 19PAIR 1.5mm S1/S5
RFOU(I) 19PAIR 1.5mm S1/S5
RFOU(I) 24PAIR 1.5mm S1/S5
RFOU(I) 24PAIR 1.5mm S1/S5

Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE

www.drakaMOG.com
274

Stock item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-

EAN No. DNK


7021528920000
7021528920017
7021528920062
7021528920079
7021528920185
7021528920192
7021528920307
7021528920314
7021528920369
7021528920376
7021528920420
7021528920437
7021528920451
7021528920468
7021528920482
7021528920499
7021528920604
7021528920611
7021528920666
7021528920673
7021528920789
7021528920796
7021528920901
7021528920918
7021528920963
7021528920970
7021528921021
7021528921038
7021528921069
7021528921083
7021528921090
7021528922004
7021528922011
7021528922066
7021528922073
7021528922189
7021528922196
7021528922301
7021528922318
7021528922363
7021528922370
7021528922424
7021528922431
7021528922455
7021528922462
7021528922486
7021528922493

EL No.
1044620
1044619
1044621
1044622
1044623
1044624
1044628
1044629
1044630
1044631
1044633
1044632
1044634
1044635
1044636
1044637
1044690
1044689
1044691
1044692
1044693
1044694
1044697
1044698
1044699
1044700
1044701
1044702
1044707
1044708
1044460
1044459
1044661
1044662
1044663
1044664
1044668
1044669
1044670
1044671
1044673
1044672
1044674
1044675
1044678
1044679

RFOU(I) 250V(3).doc
03/06/2008 10:46:00
Page 5 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable


Part number
892254
892255
892260
892261
892266
892278
892279
892290
892291
892296
892297
892302
892303
892308
892309
892400
892406
892418

Description
RFOU(I) 32PAIR 1.5mm S1/S5
RFOU(I) 32PAIR 1.5mm S1/S5
RFOU(I) 1TRIP 1.5mm S1/S5
RFOU(I) 1TRIP 1.5mm S1/S5
RFOU(I) 2TRIP 1.5mm S1/S5
RFOU(I) 4TRIP 1.5mm S1/S5
RFOU(I) 4TRIP 1.5mm S1/S5
RFOU(I) 8TRIP 1.5mm S1/S5
RFOU(I) 8TRIP 1.5mm S1/S5
RFOU(I) 12TRIP 1.5mm S1/S5
RFOU(I) 12TRIP 1.5mm S1/S5
RFOU(I) 16TRIP 1.5mm S1/S5
RFOU(I) 16TRIP 1.5mm S1/S5
RFOU(I) 24TRIP 1.5mm S1/S5
RFOU(I) 24TRIP 1.5mm S1/S5
RFOU(I) 1PAIR 2.5mm S1/S5
RFOU(I) 2PAIR 2.5mm S1/S5
RFOU(I) 4PAIR 2.5mm S1/S5

Sheath Colour
GREY
BLUE
GREY
BLUE
GREY
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY

Stock item
Yes
-

EAN No. DNK


7021528922547
7021528922554
7021528922608
7021528922615
7021528922660
7021528922783
7021528922790
7021528922905
7021528922912
7021528922967
7021528922974
7021528923025
7021528923032
7021528923087
7021528923094
7021528924008
7021528924060
7021528924183

EL No.
1044560
1044559
1044762
1044764
1044765
1044768
1044769
1044770
1044771
1044773
1044772
1044779
1044780
-

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
275

Minimum Installation
Temperature
-20C

RFOU-HCF-12kv-HF_2006.doc
30.06.2006 08:49
Page 1 of 3

RFOU-HCF 6/10(12)kV P30 / 1100C / 30-60 minutes


HydroCarbon Fire resistant, flame retardant
halogen-free medium voltage power cable.

RFOU-HCF
6/10(12)kV
EPR/EPR/TCWB/EVA/HCF/SHF1
NEK 606 Code P30

1100C / 2000F / 200 kW/m

Operating temperature
Operating Voltage

: 90C
: 6/10(12)kV

Standards applied

Application
Fixed installation for medium voltage (MV) power in both
EX- and safe areas, emergency and critical systems
where requirement for fire resistance is vital.

IEC 60092-354
Draka Norsk Kabel
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60331-21
UL 1709 / ASTM E1529
IEC 600754-1,2
IEC 61034-1,2

- Design
- HCF protection
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Fire Resistant
- HC Fire resistance
- Halogen Free
- Low Smoke

Construction
Code Letter
Conductor
Conductor screen
semiconductive
Insulation
Insulation screen
semicoductive

Tinned stranded and compressed copper (STCC), IEC 60228 class 2


Semiconductive layer (EP-rubber)
R

Lay up / Shielding
Inner covering
Tape over
bedding
Armour/screen
Tape over
armour/screen
Outer sheath

EP-rubber, IEC 60092-351 (EPR)


Semiconductive layer (EP-rubber)
Cores are laid up together. Cores are identified by White, Black or Red
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoset compound
PET tape

Tinned copper wire braid


PET tape

Flame retardant, halogen-free and mud resistant thermoset compound,


SHF2 (IEC 60092-359)

www.drakaMOG.com
276

RFOU-HCF-12kv-HF_2006.doc
30.06.2006 08:49
Page 2 of 3

RFOU-HCF 6/10(12)kV P30 / 1100C / 30-60 minutes


HCF protection
Tape
Overall sheath
Marking text
Outer sheath
colour

Code Letter
Extruded heatblock compound
-HCF
Lapped glassfibre tape
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092359)
Eg. "meter" "r" DRAKA NORSK KABEL RFOU-HCF 6/10(12)kV P30 1x
70/16 mm2 HCF 1100/60 FLEX - FLAME
Red

Range and dimensions


Draka
Norsk Kabel
part no.

Type
[mm2]

Diameter
over bedding
[mm]

Thickness of
armour
wires
[mm]

Diameter
sheath

Diameter
overall HCFprotection

[mm]

Weight
of cable
approx.
[kg/km]

(mm)
886498

Type

1x 70/16
1x 95/16
1x 120/20
1x 150/19
1x 185/18
1x 240/21
1x 300/29

23,51,5
25,51,5
27,51,5
28,51,5
30,51,5
33,01,5
35,01,5

0,3
0,3
0,3
0,3
0,3
0,3
0,3

30,02,0
32,02,0
34,02,0
35,02,0
36,52,0
39,02,0
41,52,5

62,03,0
64,53,0
66,53,0
67,53,0
69,03,0
72,03,5
74,53,5

5220
5900
6340
6670
7320
8250
9280

3x 50/31
3x 95/50
3x 150/75

47,02,0
54,02,0
60,02,5

0,4
0,4
0,6

55,03,0
62,53,5
70,53,0

89,04,5
97,05,0
106,06,0

10970
14230
17400

Diameter of
copper
conductor
approx. mm

Insulation
thickness,
nominal
mm

Semiconducting
layer
thickness
approx. mm

Diameter over
insulated, screened
conductor,
approx. mm

1x 70/16
1x 95/16
1x 120/20
1x 150/19
1x 185/18
1x 240/21
1x 300/29

10,3
12,1
13,6
15,1
16,8
19,1
21.5

3,4
3,4
3,4
3,4
3,4
3,4
3,4

0,8
0,8
0,8
0,8
0,8
0,8
0,8

21,5
23,0
24,5
26,0
28,0
30,0
32,5

3x 50/31
3x 95/50
3x 150/75

8,8
12,1
15,1

3,4
3,4
3,4

0,8
0,8
0,8

20,0
23,0
26,0

(mm)

www.drakaMOG.com
277

RFOU-HCF-12kv-HF_2006.doc
30.06.2006 08:49
Page 3 of 3

RFOU-HCF 6/10(12)kV P30 / 1100C / 30-60 minutes


ELECTRICAL DATA
No. of cores
x cross
section
[mm2]

Conductor resistance
DC
[/km]
at 20 C
at 90 C

Reactance
[/km]
at 50 Hz

Impedance
[/km] at 90
C
at 50 Hz

Continous
current
rating
at 45 C

Short circuit
(conductor)
[Ampere]
1 sec
0,3 sec

1x 70/16
1x 95/16
1x 120/20
1x 150/19
1x 185/18
1x 240/21
1x 300/29

0,270
0,195
0,154
0,126
0,100
0,0762
0,0607

0,344
0,249
0,196
0,161
0,128
0,0972
0,0774

0,172
0,164
0,159
0,153
0,148
0,143
0,137

0,385
0,298
0,253
0,222
0,195
0,173
0,158

242
293
339
389
444
522
601

9800
13300
16800
21000
25900
33600
42000

17892
24282
30672
38340
47286
61344
76681

3x 50/31
3x 95/50
3x 150/75

0,391
0,195
0,1126

0,499
0,249
0,161

0,108
0,098
0,092

0,261
0,268
0,185

137
205
272

7000
13300
21000

12780
24282
38340

INSTALLATION DATA
TYPE
[mm2]

Overall
Diameter
[mm]

Minimum bending radius


During
Fixed
Installation
Installed
[mm]
20 x D
12 x D

Maximum
pulling tension
[N]

1 x70/16
1x 95/16
1x 120/20
1x 150/19
1x 185/18
1x 240/21
1x 300/29

62,03,0
64,53,0
66,53,0
67,53,0
69,03,0
72,03,5
74,53,5

1240
1290
1330
1350
1380
1440
1490

744
774
798
810
828
864
894

3500
4750
6000
7500
9250
12000
15000

3x 50/31
3x 95/50
3x 150/75

89,04,5
97,05,0
106,06,0

1780
1940
2120

1068
1164
1272

7500
14250
20000

Minimum installation temperature: - 10 C

www.drakaMOG.com
278

RU 1kV(3).doc
29.12.2006 10:47
Page 1 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Flame retardant halogen-free power
cable. Mud resistant

RU 0,6/1kV
EPR/EVA
NEK 606 CodeP18

Operating temperature
Operating Voltage

: 90C
: 0,6/1kV

Standards applied

Application
Fixed installation for power,control and lighting in both EX- and
safe areas, general purposes. For installation in areas exposed to
MUD and drilling/cleaning fluids.

IEC 60092-353
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 60754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation
Lay up / Shielding

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2


R

EP-rubber, IEC 60092-351 (EPR)


Cores laid up in concentric layers

Inner covering

No inner covering. (Additional tapes may be applied)

Armour/screen

No armour.

Outer sheath
Marking text
Outer sheath
colour

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2


(IEC 60092-359)
E.g. "meter" "year" DRAKA NORSK KABEL RU 0,6/1KV P18 3 x 2,5 mm2 IEC
60332-3-22
Black

www.drakaMOG.com
279

RU 1kV(3).doc
29.12.2006 10:47
Page 2 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Core identification power cables
Grey (Offwhite)
Single core
Two cores
Grey (Offwhite) - Black
Three cores
Grey (Offwhite) - Black - Red
Four cores
Grey (Offwhite) - Black - Red - Blue
Five cores
Grey (Offwhite) - Black - Red - Blue - Black
Above five cores
Black numbers on white base
Separate earth core
Yellow/green
G / x in cable description
G = one of the core are yellow/green - x = no yellow/green core
From Q3 2007 the core colours
Cenelec HD 308S2 colours:
Single core
Two cores
Two cores + earth
Three cores
Three cores + earth
Four cores
Four cores + earth
Five cores
Above five cores

on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow


Black
Blue - Brown
Blue - Brown - Yellow/green
Brown - Black - Grey
Brown - Black - Grey - Yellow/green
Blue - Brown - Black - Grey
Blue - Brown - Black - Grey - Yellow/green
Blue - Brown - Black - Grey - Black
Black numbers on white base

Range and dimensions


Number of
elements

Cross
section
core, mm

Thickness
Conductor
Insulation
Outer Sheath,
Diameter, mm Thickness, mm
mm

Diameter
outer sheath,
mm

1
1
1
1
1
1
1
1
2
3G
3
4G
4
7G
5
7
12
19
24
2
3G
3
4G
4
5G

50
70
95
120
150
185
240
300
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5

9.0
10.9
12.60
14.20
15.90
17.7
20.15
22.60
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0

14.5 0.8
16.5 0.8
19 0.8
20.5 1
23 1
25 1
28.5 1
31.5 1.5
9.5 0.5
10 0.8
10 0.8
11 0.8
11 0.8
13.5 0.8
12 0.8
13.5 0.8
18 0.8
21 1
25 1
10.5 0.8
11 0.8
11 0.8
12 0.8
12 0.8
13.5 0.8

1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0

1.2
1.3
1.4
1.4
1.5
1.6
1.7
1.8
1.1
1.1
1.1
1.1
1.1
1.2
1.2
1.2
1.4
1.5
1.6
1.1
1.1
1.1
1.2
1.2
1.2

www.drakaMOG.com
280

Copper
Weight of Cable
content
Approx.
Approx.
(Kg/Km)
(kg/km)
600
428
820
620
1100
836
1370
1075
1690
1336
2070
1663
2690
2173
3360
2751
135
28
160
42
160
42
190
56
190
56
290
97
240
70
290
98
480
167
700
264
890
333
170
46
205
69
205
69
255
92
250
92
320
114

RU 1kV(3).doc
29.12.2006 10:47
Page 3 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Number of
elements

Cross
section
core, mm

Thickness
Conductor
Insulation
Outer Sheath,
Diameter, mm Thickness, mm
mm

Diameter
outer sheath,
mm

7
2
3G
3
4G
4
5G
2
3G
3
4
5G
4G
2
3
4G
5G
3
4
3G
4G
5G
4
4G
2
4G
5G
3
5G
3
5G

2.5
4
4
4
4
4
4
6
6
6
6
6
6
10
10
10
10
16
16
16
16
16
25
25
35
35
35
50
50
70
70

2.0
2.55
2.55
2.55
2.55
2.55
2.55
3.15
3.15
3.15
3.15
3.15
3.15
4.05
4.05
4.05
4.05
5.15
5.15
5.15
5.15
5.15
6.45
6.45
7.65
7.65
7.65
9.0
9.0
10.85
10.85

14.5 0.8
11.5 0.8
12 0.8
12 0.8
13.5 0.8
13.5 0.8
15 0.8
12.5 0.8
13.5 0.8
13.5 0.8
15 0.8
16.5 0.8
15 0.8
14.5 0.8
15.5 0.8
17.5 0.8
19 0.8
18 0.8
20 1
18.5 0.8
20 1
22.5 1
24.5 1
25 1
23 1
28 1
31 1.5
29 1
36.5 1.5
33.5 1.5
42 2

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4

1.3
1.2
1.2
1.2
1.2
1.2
1.3
1.2
1.2
1.2
1.3
1.3
1.3
1.2
1.3
1.3
1.4
1.4
1.4
1.4
1.4
1.5
1.6
1.6
1.5
1.7
1.8
1.8
2
2
2.1

Copper
Weight of Cable
content
Approx.
Approx.
(Kg/Km)
(kg/km)
390
160
225
74
275
110
275
110
340
147
340
147
410
183
290
109
360
164
380
163
450
218
550
272
450
218
410
181
520
271
660
361
820
451
760
434
950
579
770
434
970
578
1190
722
1420
916
1490
917
1150
618
1920
1236
2340
1544
2050
1287
3280
2144
2840
1863
4480
3105

Ordering information
Part number
831703
831704
831705
831706
831707
831708
831709
831710
831715
831716
831718
831719
831721
831723
831724
831725

Description
RU 0.6/1kV 1X 50mm P18
RU 0,6/1KV 1X 70 MM2 P18
RU 0.6/1kV 1X 95mm P18
RU 0.6/1kV 1X 120mm P18
RU 0.6/1kV 1X 150mm P18
RU 0,6/1KV 1X185 MM2 P18
RU 0.6/1kV 1X 240mm P18
RU 0.6/1kV 1X 300mm P18
RU 0.6/1kV 2X 1.5mm P18
RU 0.6/1kV 3G 1.5mm P18
RU 0.6/1kV 3X 1.5mm P18
RU 0.6/1kV 4G 1.5mm P18
RU 0.6/1kV 4X 1.5mm P18
RU 0.6/1kV 7G 1.5mm P18
RU 0.6/1kV 5X 1.5mm P18
RU 0.6/1kV 7X 1.5mm P18

Sheath Colour
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK

Stock item
-

www.drakaMOG.com
281

EAN No. DNK


7021528317039
7021528317046
7021528317053
7021528317060
7021528317077
7021528317084
7021528317091
7021528317107
7021528317152
7021528317169
7021528317183
7021528317190
7021528317213
7021528317237
7021528317244
7021528317251

EL No.
1061403
1061407
-

RU 1kV(3).doc
29.12.2006 10:47
Page 4 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Part number
831726
831728
831729
831733
831734
831736
831737
831739
831740
831743
831751
831752
831753
831754
831755
831756
831759
831760
831761
831762
831763
831764
831766
831767
831769
831770
831773
831774
831775
831776
831777
831781
831782
831785
831788
831789
831792
831796
831798
831799

Description
RU 0,6/1KV 12X 1,5 MM2 P18
RU 0.6/1kV 19X 1.5mm P18
RU 0,6/1KV 24X 1,5 MM2 P18
RU 0.6/1kV 2X 2.5mm P18
RU 0.6/1kV 3G 2.5mm P18
RU 0.6/1kV 3X 2.5mm P18
RU 0.6/1kV 4G 2.5mm P18
RU 0,6/1KV 4X 2,5 MM2 P18
RU 0.6/1kV 5G 2.5mm P18
RU 0,6/1KV 7X 2,5 MM2 P18
RU 0,6/1KV 2X 4 MM2 P18
RU 0.6/1kV 3G 4mm P18
RU 0.6/1kV 3X 4mm P18
RU 0.6/1kV 4G 4mm P18
RU 0,6/1KV 4X 4 MM2 P18
RU 0,6/1KV 5G 4mm P18
RU 0,6/1KV 2X 6 MM2 P18
RU 0.6/1kV 3G 6mm P18
RU 0,6/1KV 3X 6MM2 P18
RU 0.6/1kV 4X 6mm P18
RU 0.6/1kV 5G 6mm P18
RU 0.6/1kV 4G 6mm P18
RU 0,6/1KV 2X 10 MM2 P18
RU 0,6/1KV 3X 10 MM2 P18
RU 0.6/1kV 4G 10mm P18
RU 0.6/1kV 5G 10mm P18
RU 0,6/1KV 3X 16 MM2 P18
RU 0,6/1KV 4X 16 MM2 P18
RU 0.6/1kV 3G 16mm P18
RU 0.6/1kV 4G 16mm P18
RU 0.6/1kV 5G 16mm P18
RU 0,6/1KV 4X 25 MM2 P18
RU 0.6/1kV 4G 25mm P18
RU 0,6/1KV 2X 35 MM2 P18
RU 0.6/1kV 4G 35mm P18
RU 0.6/1kV 5G 35mm P18
RU 0,6/1KV 3X 50 MM2 P18
RU 0.6/1kV 5G 50mm P18
RU 0,6/1KV 3X 70 MM2 P18
RU 0.6/1kV 5G 70mm P18

Sheath Colour
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK
BLACK

Stock item
-

EAN No. DNK


7021528317268
7021528317282
7021528317299
7021528317336
7021528317343
7021528317367
7021528317374
7021528317398
7021528317404
7021528317435
7021528317510
7021528317527
7021528317534
7021528317541
7021528317558
7021528317565
7021528317596
7021528317602
7021528317619
7021528317626
7021528317633
7021528317640
7021528317664
7021528317671
7021528317695
7021528317701
7021528317732
7021528317749
7021528317756
7021528317763
7021528317770
7021528317817
7021528317824
7021528317855
7021528317886
7021528317893
7021528317923
7021528317961
7021528317985
7021528317992

EL No.
1061434
1061437
-

Electrical values power cables


Number of
elements

Cross
section
core, mm

1
1
1
1
1
1
1

50
70
95
120
150
185
240

Max. conductor
resistance at
20C, Ohm/km
0.391
0.27
0.195
0.154
0.126
0.1
0.0762

Max. conductor
resistance at
90C, Ohm/km
0.499
0.344
0.249
0.196
0.161
0.128
0.0972

Reactance at
50Hz,
Ohm/km
0.089
0.099
0.084
0.082
0.082
0.081
0.080

Reactance at
60Hz,
Ohm/km
0.107
0.120
0.101
0.099
0.098
0.098
0.096

www.drakaMOG.com
282

Current rating
IEC 60092-352
Table B.4,
Ampere
196
242
293
339
389
444
522

Short circuit
rating 1
second,
Ampere
7000
9800
13300
16800
21000
25900
33600

RU 1kV(3).doc
29.12.2006 10:47
Page 5 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Number of
elements

Cross
section
core, mm

1
2
3G
3
4G
4
7G
5
7
12
19
24
2
3G
3
4G
4
5G
7
2
3G
3
4G
4
5G
2
3G
3
4
5G
4G
2
3
4G
5G
3
4
3G
4G
5G
4
4G
2
4G
5G
3
5G
3
5G

300
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
6
6
6
6
6
6
10
10
10
10
16
16
16
16
16
25
25
35
35
35
50
50
70
70

Max. conductor
resistance at
20C, Ohm/km
0.0607
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.7
4.7
4.7
4.7
4.7
4.7
3.11
3.11
3.11
3.11
3.11
3.11
1.84
1.84
1.84
1.84
1.16
1.16
1.16
1.16
1.16
0.734
0.734
0.529
0.529
0.529
0.391
0.391
0.27
0.27

Max. conductor
resistance at
90C, Ohm/km
0.0774
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
15.6
9.64
9.64
9.64
9.64
9.64
9.64
9.64
5.99
5.99
5.99
5.99
5.99
5.99
3.97
3.97
3.97
3.97
3.97
3.97
2.35
2.35
2.35
2.35
1.48
1.48
1.48
1.48
1.48
0.936
0.936
0.675
0.675
0.675
0.499
0.499
0.344
0.344

Reactance at
50Hz,
Ohm/km
0.080
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.110
0.102
0.103
0.103
0.103
0.103
0.103
0.103
0.096
0.096
0.096
0.096
0.096
0.096
0.090
0.090
0.090
0.090
0.090
0.090
0.084
0.084
0.084
0.084
0.080
0.080
0.080
0.080
0.103
0.079
0.079
0.076
0.076
0.076
0.076
0.076
0.075
0.076

Reactance at
60Hz,
Ohm/km
0.096
0.132
0.132
0.132
0.132
0.132
0.132
0.132
0.132
0.132
0.132
0.132
0.123
0.123
0.123
0.123
0.123
0.123
0.123
0.115
0.115
0.115
0.115
0.115
0.115
0.108
0.108
0.108
0.108
0.108
0.108
0.101
0.101
0.101
0.101
0.096
0.096
0.096
0.096
0.123
0.095
0.095
0.092
0.092
0.092
0.092
0.092
0.091
0.092

www.drakaMOG.com
283

Current rating
IEC 60092-352
Table B.4,
Ampere
601
20
20
16
16
16
12.5
13.5
12
10
8.5
8
26
26
21
21
21
21
15.5
34
34
28
28
28
28
44
44
36
36
36
36
61
50
50
50
67
67
80
67
67
89
89
133
110
110
137
137
169
169

Short circuit
rating 1
second,
Ampere
42000
210
210
210
210
210
210
210
210
210
210
210
350
350
350
350
350
350
350
560
560
560
560
560
560
840
840
840
840
840
840
1400
1400
1400
1400
2240
2240
2240
2240
2240
3500
3500
4900
4900
4900
7000
7000
9800
9800

RU 1kV(3).doc
29.12.2006 10:47
Page 6 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Ambient temperature correction factors
Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
284

Minimum Installation
Temperature
-20C

RU(c) 250V(3).doc
29.12.2006 10:15
Page 1 of 3

RU(c) 250V S12 Instrumentation cable, Unarmoured


Flame retardant halogen-free
instrumentation cable. Mud resistant

RU(c) 250V
EPR/EVA
NEK 606 CodeS12

Operating temperature
Operating Voltage

: 90C
: 250V

Standards applied

Application
Fixed installation for instrumentation, communication, Control
and alarm systems in both EX- (Zone 2) and safe areas.
Meets the mud resistant requirements in NEK 606.

IEC 60092-376 (2003-05)


IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 600754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2

Inner covering

EP-rubber, IEC 60092-351 (EPR)


Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
are laid up collectively and screened by copper backed polyester tape with tinned
copper drain wire. Pairs/triples are identified by numbers printed directly on the
insulated conductors.
No inner covering. (Additional tapes may be applied)

Armour/screen

No armour.

Pair / Triple /
Quad twisting

Outer sheath
Marking text
Outer sheath
colour

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-359)
E.g. "meter" "year" DRAKA NORSK KABEL RU(c) 250V S12 2 pair 0,75 mm2 IEC
60092-376 IEC 60332-3-22
Grey or Blue

Core identification instrumentation cables


Black - Light Blue
Pair
Triple
Black - Light Blue - Brown
Quad
Black - Light Blue - Brown - Grey

www.drakaMOG.com
285

RU(c) 250V(3).doc
29.12.2006 10:15
Page 2 of 3

RU(c) 250V S12 Instrumentation cable, Unarmoured


Range and dimensions
No of
Number of
cores in
elements
element

Cross
Conductor
section
Diameter,
core, mm mm

Insulation
Thickness,
mm

2
4
8
12
16
19
24
2
4
8
16
24
2
4
8
12
12
16
24
2
4
8
12
16
24

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

2
2
2
2
2
2
2
3
3
3
3
3
2
2
2
2
2
2
2
3
3
3
3
3
3

1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

Electrical values instrumentation cables


Capacitance, approx.
Type
(nF/km)
Unshielded pair 0,75 mm
100

Weight of
Thickness
Diameter
Cable
Outer Sheath, outer sheath,
Approx.
mm
mm
(Kg/Km)
1.1
10 0.8
140
1.1
11.5 0.8
200
1.3
16 0.8
410
1.4
18 0.8
530
1.5
19.5 0.8
660
1.5
20.5 1
750
1.7
24 1
950
1.1
11 0.8
170
1.2
13 0.8
270
1.4
17.5 0.8
530
1.6
22 1
900
1.8
27 1
1300
1.2
12 0.8
210
1.2
14 0.8
320
1.4
19.5 0.8
630
1.6
22.5 1
850
1.6
22.5 1
850
1.7
24.5 1
1080
1.9
30 1.5
1550
1.2
13.5 0.8
265
1.3
16 0.8
430
1.5
21.5 1
840
1.7
25.5 1
1170
1.8
27.5 1
1500
2.1
34 1.5
2210

Copper
content
Approx.
(kg/km)
33
60
116
172
227
269
338
47
89
172
341
508
62
118
229
339
339
450
672
91
174
341
509
676
1010

Inductance, approx,
(mH/km)
0,67

Resistance at 20C, max.


(Ohm/km)
24,8

L/R ratio,
(microH/Ohm)
14,3

Unshielded triple 0,75 mm

100

0,67

24,8

14,3

Unshielded pair 1,5 mm

110

0,63

12,2

26,6

Unshielded triple 1,5 mm

110

0,63

12,2

26,6

Unshielded pair 2,5 mm

125

0,59

7,56

39,0

Unshielded triple 2,5 mm

125

0,59

7,56

39,0

Ordering information
Part number
895606
895618
895630
895636
895642
895645
895648
895666

Description
RU(C) 250V 2PAIR 0.75mm S12
RU(C) 250V 4PAIR 0.75mm S12
RU(C) 250V 8PAIR 0.75mm S12
RU(C) 250V 12PAIR 0.75mm S12
RU(C) 250V 16PAIR 0.75mm S12
RU(C) 250V 19PAIR 0.75mm S12
RU(C) 250V 24PAIR 0.75mm S12
RU(C) 250V 2TRIP 0.75mm S12

Sheath Colour
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY

www.drakaMOG.com
286

Stock item
-

EAN No. DNK


7021528956061
7021528956184
7021528956306
7021528956368
7021528956429
7021528956450
7021528956481
7021528956665

EL No.
-

RU(c) 250V(3).doc
29.12.2006 10:15
Page 3 of 3

RU(c) 250V S12 Instrumentation cable, Unarmoured


Part number
895678
895690
895702
895708
895806
895818
895830
895836
895837
895842
895848
895866
895878
895890
895896
895902
895908

Description
RU(C) 250V 4TRIP 0.75mm S12
RU(C) 250V 8TRIP 0.75mm S12
RU(C) 250V 16TRIP 0.75mm S12
RU(C) 250V 24TRIP 0.75mm S12
RU(C) 250V 2PAIR 1.5mm S12
RU(C) 250V 4PAIR 1.5mm S12
RU(C) 250V 8PAIR 1.5mm S12
RU(C) 250V 12PAIR 1.5mm S12
RU(C) 250V 12PAIR 1.5mm S12
RU(C) 250V 16PAIR 1.5mm S12
RU(C) 250V 24PAIR 1.5mm S12
RU(C) 250V 2TRIP 1.5mm S12
RU(C) 250V 4TRIP 1.5mm S12
RU(C) 250V 8TRIP 1.5mm S12
RU(C) 250V 12TRIP 1.5mm S12
RU(C) 250V 16TRIP 1.5mm S12
RU(C) 250V 24TRIP 1.5mm S12

Sheath Colour
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY

Stock item
-

EAN No. DNK


7021528956788
7021528956900
7021528957020
7021528957082
7021528958065
7021528958188
7021528958300
7021528958362
7021528958379
7021528958423
7021528958485
7021528958669
7021528958782
7021528958904
7021528958966
7021528959024
7021528959086

EL No.
-

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
287

Minimum Installation
Temperature
-20C

RU(i) 250V(4).doc
29.12.2006 10:09
Page 1 of 3

RU(i) 250V S11 Instrumentation cable, Unarmoured


Flame retardant halogen-free instrumentation
cable. Mud resistant

RU(i) 250V
EPR/EVA
NEK 606 CodeS11

Operating temperature
Operating Voltage

: 90C
: 250V

Standards applied

Application
Fixed installation for instrumentation, communication,
Control and alarm systems in both EX- (Zone 2) and safe
areas. Meets the mud resistant requirements in NEK 606.

IEC 60092-376 (2003-05)


IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 600754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Insulation

Tinned annealed stranded circular copper (STCC), IEC 60228 class 2

Lay up /
Shielding
Inner covering

EP-rubber, IEC 60092-351 (EPR)


Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbers printed directly on the insulated conductors.
Individually shielded pairs/triples/quads are laid up in concentric layers and
wrapped with a PETP tape.
No inner covering. (Additional tapes may be applied)

Armour/screen

No armour.

Pair / Triple /
Quad twisting

Outer sheath
Marking text
Outer sheath
colour

Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
60092-359)
E.g. "meter" "year" DRAKA NORSK KABEL RU(i) 250V S11 2 pair 0,75 mm2 IEC
60092-376 IEC 60332-3-22
Grey or Blue

Core identification instrumentation cables


Black - Light Blue
Pair
Triple
Black - Light Blue - Brown
Quad
Black - Light Blue - Brown - Grey

www.drakaMOG.com
288

RU(i) 250V(4).doc
29.12.2006 10:09
Page 2 of 3

RU(i) 250V S11 Instrumentation cable, Unarmoured


Range and dimensions
No of
Number of
cores in
elements
element

Cross
Conductor
section
Diameter,
core, mm mm

Insulation
Thickness,
mm

1
1
2
2
4
8
12
16
24
1
2
4
8
12
16
24
1
1
2
2
4
8
12
16
24
1
2
4
8
16
24

0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5

0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7

2
2
2
2
2
2
2
2
2
3
3
3
3
3
3
3
2
2
2
2
2
2
2
2
2
3
3
3
3
3
3

1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.1
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6
1.6

Electrical values instrumentation cables


Capacitance, approx.
Type
(nF/km)
Shielded pair 0,75 mm
110
Shielded triple 0,75 mm
110
Shielded pair 1,5 mm
125
Shielded triple 1,5 mm
125
Shielded pair 2,5 mm
145
Shielded triple 2,5 mm
145

Weight of
Thickness
Diameter
Cable
Outer Sheath, outer sheath,
Approx.
mm
mm
(Kg/Km)
1
6.5 0.5
85
1
6.5 0.5
85
1.1
10 0.8
145
1.1
10 0.8
145
1.2
11.5 0.8
240
1.3
16 0.8
450
1.5
19 0.8
630
1.5
21 1
790
1.7
25.5 1
1160
1
7 0.5
100
1.2
11 0.8
185
1.2
13 0.8
300
1.4
17.5 0.8
580
1.6
21.5 1
810
1.6
23.5 1
1030
1.9
29.5 1
1540
1
8 0.5
120
1
8 0.5
120
1.2
12 0.8
220
1.2
12 0.8
220
1.3
14.5 0.8
370
1.5
19.5 0.8
710
1.6
23.5 1
980
1.7
26.5 1
1270
2
32.5 1.5
1900
1
8.5 0.5
140
1.3
14 0.8
285
1.3
16 0.8
470
1.6
22 1
920
1.9
30 1.5
1710
2.2
37 1.5
2540

Inductance, approx,
(mH/km)
0,67
0,67
0,63
0,63
0,59
0,59

Resistance at 20C, max.


(Ohm/km)
24,8
24,8
12,2
12,2
7,56
7,56

Copper
content
Approx.
(kg/km)
18.5
18.5
37
37
74
147
220
293
439
26
51
102
203
305
406
609
35
35
69
69
137
274
411
548
822
49
97
194
387
774
1161

L/R ratio,
(microH/Ohm)
14,3
14,3
26,6
26,6
39,0
39,0

Ordering information
Part number
895000
895001
895006

Description
RU(I) 250V 1PAIR 0.75mm S11
RU(I) 250V 1PAIR 0.75mm S11
RU(I) 250V 2PAIR 0.75mm S11

Sheath Colour
GREY
BLUE
GREY

www.drakaMOG.com
289

Stock item
-

EAN No. DNK


7021528950007
7021528950014
7021528950069

EL No.
-

RU(i) 250V(4).doc
29.12.2006 10:09
Page 3 of 3

RU(i) 250V S11 Instrumentation cable, Unarmoured


Part number
895007
895018
895030
895036
895042
895048
895060
895066
895078
895090
895096
895102
895108
895200
895201
895206
895207
895218
895230
895236
895242
895248
895260
895266
895278
895290
895302
895308

Description
RU(I) 250V 2PAIR 0.75mm S11
RU(I) 250V 4PAIR 0.75mm S11
RU(I) 250V 8PAIR 0.75mm S11
RU(I) 250V 12PAIR 0.75mm S11
RU(I) 250V 16PAIR 0.75mm S11
RU(I) 250V 24PAIR 0.75mm S11
RU(I) 250V 1TRIP 0.75mm S11
RU(I) 250V 2TRIP 0.75mm S11
RU(I) 250V 4TRIP 0.75mm S11
RU(I) 250V 8TRIP 0.75mm S11
RU(I) 250V 12TRIP 0.75mm S11
RU(I) 250V 16TRIP 0.75mm S11
RU(I) 250V 24TRIP 0.75mm S11
RU(I) 250V 1PAIR 1.5mm S11
RU(I) 250V 1PAIR 1.5mm S11
RU(I) 250V 2PAIR 1.5mm S11
RU(I) 250V 2PAIR 1.5mm S11
RU(I) 250V 4PAIR 1.5mm S11
RU(I) 250V 8PAIR 1.5mm S11
RU(I) 250V 12PAIR 1.5mm S11
RU(I) 250V 16PAIR 1.5mm S11
RU(I) 250V 24PAIR 1.5mm S11
RU(I) 250V 1TRIP 1.5mm S11
RU(I) 250V 2TRIP 1.5mm S11
RU(I) 250V 4TRIP 1.5mm S11
RU(I) 250V 8TRIP 1.5mm S11
RU(I) 250V 16TRIP 1.5mm S11
RU(I) 250V 24TRIP 1.5mm S11

Sheath Colour
BLUE
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY
GREY

Stock item
-

EAN No. DNK


7021528950076
7021528950182
7021528950304
7021528950366
7021528950427
7021528950489
7021528950601
7021528950663
7021528950786
7021528950908
7021528950960
7021528951028
7021528951080
7021528952001
7021528952018
7021528952063
7021528952070
7021528952186
7021528952308
7021528952360
7021528952421
7021528952483
7021528952605
7021528952667
7021528952780
7021528952902
7021528953022
7021528953084

EL No.
-

Installation recommendations
Minimum Bending Radius during
Installation
8xD

Minimum Bending Radius


Fixed Installed
6xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
290

Minimum Installation
Temperature
-20C

UX 1000V.doc
26.03.2006 19:12
Page 1 of 2

UX 1000V P15
2

Flame retardant conductors

UX 1000V
Halogen-free, NEK 606 Type: P15
Maximum operating
Conductor temperature : 90C
Operating voltage
: 1000V

Application

Standards applied

Insulated conductor for earthing and bonding services.


Mud resistant in accordance with NEK 606.

IEC:60092-353 &
NEK 606
IEC:60332-3-22
IEC:60754-1,2
IEC:61034-1,2

- Design guidelines
- Flame retardance
- Halogen-free properties
- Smoke density

CONSTRUCTION
CODE LETTER
Conductor
Insulation

Unsheathed

Tinned, stranded copper. (1)


PETP-tape. (2)
Flame retardant halogen-free thermoset compound. (3)

Marking

E.g; meter year DRAKA NORSK KABEL UX 1000V P15


1x 95 mm IEC 332-3-22

Colour

Yellow/green

www.drakaMOG.com
291

UX 1000V.doc
26.03.2006 19:12
Page 2 of 2

UX 1000V P15
RANGE AND DIMENSIONS: UX 1000V Insulated conductor, P15
Conductor area
(mm)

Conductor
diameter
approx.
(mm)

Insulation
thickness
(mm)

Diameter
over
insulation
(mm)

Weight of
conductor
approx.
(kg/km)

Copper content
approx.
(kg/km)

3,15

1,0

5,50,8

80

54

10

4,05

1,0

6,50,8

120

87

16

5,15

1,0

7,50,8

180

143

25

6,4

1,2

9,50,8

280

224

35

7,65

1,2

10,51,0

370

310

50

9,00

1,4

12,51,0

520

430

70

10,85

1,4

14,51,0

730

620

95

12,60

1,6

16,51,0

970

840

120

14,20

1,6

18,01,0

1220

1080

150

15,90

1,8

20,01,5

1520

1342

185

17,70

2,0

22,01,5

1890

1670

240

20,15

2,2

25,01,5

2450

2183

300

22,60

2,4

28,01,5

3090

2762

Installation recommendations:
In accordance with IEC 60092-352
Minimum bending radius
During installation

Maximum pulling tension

Fixed installed
25N x total
cross section of conductors

8 x cable diameter

Minium installation
temperature

6 x cable diameter

Ordering information:
Conductor area
(mm)

DRAKA NORSK KABEL


Part number
Yellow/green

El-number
(Norway only)

6
10
16
25
35
50
70
95
120
150
185
240
300

800800
800801
800802
800803
800804
800805
800806
800807
800808
800809
800810
800811
800812

1045541
1045542
1045543
1045553
1045563
1045573
1045583
1045593
1045603
1045604

www.drakaMOG.com
292

- 20 C

Shipline BI Fire resistant power cable 0.6/1 kV


Halogen free shipcable

BI 0.6/1kV
MGT/XLPE/SHF1
Max. conductor temp. : 90C
Nominal voltage
: 0.6/1 kV

Application

Standards applied

Unarmoured fire resistant cable for fixed


installations on ships where cable protection is not
required. For critical power, lighting, control, alarm
and emergency systems.
Can be installed and operated both indoors and
outdoors.

Design
Conductor
Insulation
Sheath
Fire retardant
Fire resistant
Halogen Free
Low smoke

- IEC 60092-353
- IEC 60228 class 2
- IEC 60092-351
- IEC 60092-359
- IEC 60332-3-22 (cat. A)
- IEC 60331-21
- IEC 60754-1,2
- IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector
shaped conductors, other types circular conductors

Conductor
Insulation

Mica glass tape and crosslinked polyethylene, XLPE

Lay up

Over the laid up cores one or more tapes may be applied

Inner covering

No inner covering

Outer sheath
Marking text
Outer sheath
colour

Flame retardant halogen free thermoplastic compound, SHF1


DRAKA {factory code} BI 0,6/1 kV ..x.. mm2 IEC60331 IEC60332-322 ShipLine {year of manufacture} {length indication (meter)}
Green

293

Shipline BI Fire resistant power cable 0.6/1 kV


Halogen free shipcable
Core identification
Single core
Two cores
Three cores
Four cores
Five cores
Multi core

Black
Blue - Brown
Brown - Black - Grey
Blue - Brown - Black - Grey
Blue - Brown - Black - Grey - Black
White with black numbers

with yellow/green (optional)


Two cores + earth (3G)
Three cores + earth (4G)
Four cores + earth (5G)

Yellow/green - Blue - Brown


Yellow/green - Brown - Black - Grey
Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

1.5

3.3

0.7

1.1

8.5

2.5

3.8

85

27

0.7

1.1

9.5

110

45

1.5

2.5

3.3

0.7

1.1

9.5

105

39

3.8

0.7

1.1

10.0

145

68

1.5

4.3

0.7

1.2

11.5

205

110

3.3

0.7

1.1

10.0

135

55

4.8

0.7

1.2

14.5

350

227

1.5

3.3

0.7

1.1

11.0

170

70

2.5

3.8

0.7

1.2

12.5

240

127

Conductor
type

Reactance
at 50Hz

Reactance
at 60Hz

(mm)

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

Electrical values
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

(Ohm/km)

(Ohm/km)

1.5

1.83

2.33

0.110

0.132

20

2.5

1.15

1.47

0.103

0.124

26

355

1.5

0.727

0.927

0.110

0.132

16

210

2.5

0.524

0.669

0.103

0.124

21

355

0.387

0.494

0.097

0.116

28

570

1.5

0.268

0.343

0.117

0.141

14

210

0.193

0.248

0.100

0.120

32.5

855

1.5

0.153

0.198

0.120

0.144

13

210

2.5

0.124

0.162

0.113

0.136

16.5

210

294

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)
210

Shipline BI Fire resistant power cable 0.6/1 kV


Halogen free shipcable
Ordering information
Part
number
126458
126461
126459
126462
126463
126460
127061
128218
128219

Description

EAN No.
KDN
8711401039439
8711401039460
8711401039446
8711401039477
8711401039484
8711401039453
8711401058355
8711401105233
8711401105240

BI fr 0,6/1kV gn# 2x1,5 mm2


BI fr 0,6/1kV gn# 2x2,5 mm2
BI fr 0,6/1kV gn# 3x1,5 mm2
BI fr 0,6/1kV gn# 3x2,5 mm2
BI fr 0,6/1kV gn# 3x4 mm2
BI fr 0,6/1kV gn# 4x1,5 mm2
BI fr 0,6/1kV gn# 4x6 mm2
BI fr 0,6/1kV gn# 5x1,5 mm2
BI fr 0,6/1kV gn# 5x2,5 mm2

Stock
Item
Yes
No
Yes
No
No
No
No
No
No

Ambient temperature correction factors


Ambient temp. C
Rating factor

25
1.22

30
1.17

35
1.12

40
1.06

45
1.00

50
0.94

55
0.87

60
0.79

65
0.71

70
0.61

75
0.50

Installation recommendations
Minimum bending radius
during installation
8xD

Minimum bending radius


fixed installed
6xD

Maximum tensile load


during installation
50 N * total cross section
conductors

Subject to change without notice

295

Minimum installation
temperature
-20 C

Shipline BXOI Fire resistant power cable 0.6/1 kV


Halogen free shipcable

BXOI 0.6/1kV
MGT/XLPE/TCWB/SHF1
Max. conductor temp. : 90C
Nominal voltage
: 0.6/1 kV

Application

Standards applied

Armoured fire resistant cable for fixed installations


on ships where cable protection is required.
For critical power, lighting, control, alarm and
emergency systems.
Can be installed and operated both indoors and
outdoors.

Design
Conductor
Insulation
Sheath
Fire retardant
Fire resistant
Halogen Free
Low smoke

- IEC 60092-353
- IEC 60228 class 2
- IEC 60092-351
- IEC 60092-359
- IEC 60332-3-22 (cat. A)
- IEC 60331-21
- IEC 60754-1,2
- IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector
shaped conductors, other types circular conductors

Conductor
Insulation

Mica glass tape and crosslinked polyethylene, XLPE


Over the laid up cores one or more tapes may be applied

Lay up
Inner covering

No inner covering

Armour/screen

Tinned copper wire braid

Outer sheath

Flame retardant halogen free thermoplastic compound, SHF1

Marking text
Outer sheath
colour

DRAKA {factory code} BXOI 0,6/1 kV ..x../.. mm2 IEC60331-21


IEC60332-3-22 ShipLine {year of manufacture} {length indication
(meter)}
Green

296

Shipline BXOI Fire resistant power cable 0.6/1 kV


Halogen free shipcable
Core identification
Single core
Two cores
Three cores
Four cores
Five cores
Multi core

Black
Blue - Brown
Brown - Black - Grey
Blue - Brown - Black - Grey
Blue - Brown - Black - Grey - Black
White with black numbers

with yellow/green (optional)


Two cores + earth (3G)
Three cores + earth (4G)
Four cores + earth (5G)

Yellow/green - Blue - Brown


Yellow/green - Brown - Black - Grey
Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

(mm)

35

10.8

0.7

95

16.1

185

10

1.5

2.5

2.5

0.2

1.2

13.0

480

367

0.7

0.2

1.4

19.7

1190

973

22.1

0.7

0.3

1.6

26.5

2290

1963

3.3

0.7

0.2

1.1

10.0

134

67

2.5

3.8

0.7

0.2

1.1

10.5

170

98

1.5

2.5

3.3

0.7

0.2

1.1

10.5

157

80

2.5

2.5

3.8

0.7

0.2

1.2

11.0

205

120

4.3

0.7

0.2

1.2

12.5

275

170

4.8

0.7

0.3

1.3

14.5

380

261

10

10

5.8

0.7

0.3

1.4

16.8

525

373

25

16

9.6

0.9

0.4

1.6

23.0

1150

913

35

16

10.8

0.9

0.3

1.7

26.5

1490

1169

50

25

12.1

1.0

0.4

1.7

27.0

1930

1563

70

35

13.9

1.1

0.6

2.0

30.0

2690

2238

95

50

16.1

1.1

0.6

2.2

35.5

3720

3125

1.5

3.3

0.7

0.2

1.2

12.5

240

1290

1.5

3.3

0.7

0.2

1.3

13.5

310

1870

12

1.5

3.3

0.7

0.3

1.4

18.0

470

2740

19

1.5

3.3

0.7

0.3

1.5

21.0

650

3870

297

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

Shipline BXOI Fire resistant power cable 0.6/1 kV


Halogen free shipcable
Electrical values
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Conductor
type

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

Reactance
at 50Hz

Reactance
at 60Hz

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)

35

SCC

0.524

0.669

(Ohm/km)

(Ohm/km)

0.098

95

SCC

0.193

0.118

157

5005

0.248

0.089

0.107

293

13585

185

10

SCC

1.5

2.5

SCC

0.0991

0.131

0.087

0.104

444

26455

12.1

15.4

0.110

0.132

20

2.5

2.5

210

SCC

7.41

9.45

0.103

0.124

26

1.5

2.5

355

SCC

12.1

15.4

0.110

0.132

16

210

2.5

2.5

SCC

7.41

9.45

0.103

0.124

21

355

SCC

4.61

5.88

0.097

0.116

28

570

SCC

3.08

3.93

0.093

0.111

36

855

10

10

SCC

1.83

2.33

0.089

0.107

50

1430

25

16

SCC

0.727

0.927

0.091

0.109

89

3575

35

16

SCC

0.524

0.669

0.087

0.104

110

5005

50

25

SCC

0.387

0.494

0.081

0.098

137

7150

70

35

SCC

0.268

0.343

0.078

0.094

169

10010

95

50

SCC

0.193

0.248

0.076

0.091

205

13585

1.5

SCC

12.1

15.4

0.120

0.144

13

210

1.5

SCC

12.1

15.4

0.120

0.144

12

210

12

1.5

SCC

12.1

15.4

0.120

0.144

10

210

19

1.5

SCC

12.1

15.4

0.120

0.144

8.5

210

SCC = Stranded Circular Conductor

Ordering information
Part
number
128147
128148
128149
125758
125764
125760
125763
126457
126986
125765
128142
128143
128144
128145
128146
126456
125761
125762
128220

Description
BXOI fr 0.6/1kV green 1x35/4 mm2
BXOI fr 0.6/1kV green 1x95/6 mm2
BXOI fr 0.6/1kV green 1x185/10 mm2
BXOI fr 0.6/1kV green 2x1,5/2,5 mm2
BXOI fr 0.6/1kV green 2x2,5/2,5 mm2
BXOI fr 0.6/1kV green 3x1,5/2,5 mm2
BXOI fr 0.6/1kV green 3x2,5/2,5 mm2
BXOI fr 0.6/1kV green 3x4/4 mm2
BXOI fr 0.6/1kV green 3x6/6 mm2
BXOI fr 0.6/1kV green 3x10/10 mm2
BXOI fr 0.6/1kV green 3x25/16 mm2
BXOI fr 0.6/1kV green 3x35/16 mm2
BXOI fr 0.6/1kV green 3x50/25 mm2
BXOI fr 0.6/1kV green 3x70/35 mm2
BXOI fr 0.6/1kV green 3x95/50 mm2
BXOI fr 0.6/1kV green 5x1,5/4 mm2
BXOI fr 0.6/1kV green 7x1,5/6 mm2
BXOI fr 0.6/1kV green 12x1,5/6 mm2
BXOI fr 0.6/1kV green 19x1,5/6 mm2

EAN No.
KDN
8711401104359
8711401104366
8711401104373
8711401030856
8711401030900
8711401030863
8711401030894
8711401039422
8711401050229
8711401030917
8711401104304
8711401104311
8711401104328
8711401104335
8711401104342
8711401039415
8711401030870
8711401030887
8711401105257

298

Stock
Item
N
N
N
Y
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N

Shipline BXOI Fire resistant power cable 0.6/1 kV


Halogen free shipcable

Ambient temperature correction factors


Ambient temp. C
Rating factor

25
1.22

30
1.17

35
1.12

40
1.06

45
1.00

50
0.94

55
0.87

60
0.79

65
0.71

70
0.61

75
0.50

Installation recommendations
Minimum bending radius
during installation
8xD

Minimum bending radius


fixed installed
6xD

Maximum tensile load


during installation
50 N * total cross section
conductors

Subject to change without notice

299

Minimum installation
temperature
-20 C

Shipline BXOI Fire resistant instrument cable 250V


Halogen free shipcable

BXOI 250V
MGT/XLPE/TCWB/SHF1
Max. conductor temp. : 90C
Nominal voltage
: 250V

Standards applied

Application

Design
Armoured fire resistant cable for fixed installations Conductor
Insulation
on ships where cable protection is required.
For critical control, alarm and emergency systems. Sheath
Fire retardant
Can be installed and operated both indoors and
Fire resistant
outdoors.
Halogen Free
Low smoke

- IEC 60092-353
- IEC 60228 class 2
- IEC 60092-351
- IEC 60092-359
- IEC 60332-3-22 (cat. A)
- IEC 60331-21
- IEC 60754-1,2
- IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded circular copper conductors

Conductor
Insulation

Mica glass tape and crosslinked polyethylene, XLPE


Numbered white cores twisted in pairs (two pair type may be built up
as a star quad). The pairs are twisted with different lay length to
reduce mutual capacitance. Over the laid up cores one or more tapes
may be applied

Lay up

Inner covering

No inner covering

Armour/screen

Tinned copper wire braid

Outer sheath

Flame retardant halogen free thermoplastic compound, SHF1

Marking text
Outer sheath
colour

DRAKA {factory code} BXOI 250 V .. pair/triple/quad .. mm2


IEC60092-376 IEC60331 IEC60332-3-22 ShipLine {year of
manufacture} {length indication (meter)}
Green

300

Shipline BXOI Fire resistant instrument cable 250V


Halogen free shipcable
Identification of elements
White cores with black numbers
The pairs have the following number identification
according to IEC 60092-376
Pair no. 1
Pair no. 2
Pair no. 3
Pair no. 4

core no. 1 and 2


core no. 3 and 4
core no. 5 and 6
etc.

The single triple is identified


with no 1, 2 and 3
1
The single quad cable has the
following identification

4 + 3
2

Range and dimensions


Elements
(pair)
(triple)
(quad)

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

1 pair

0.75

2.35

0.7

0.2

1.0

8.5

1 pair

1.5

95

44

2.85

0.7

0.2

1.0

9.5

115

73

2 pair

0.75

4 pair

0.75

2.35

0.7

0.2

1.2

13.0

170

73

2.35

0.7

0.2

1.2

15.5

240

108

7 pair
10 pair

0.75

2.35

0.7

0.3

1.3

18.5

390

198

0.75

2.35

0.7

0.3

1.5

23.5

550

265

(mm)

Weight
approx.
(kg/km)

Electrical values
Type

Capacitance
approx.
(nF/km)

Inductance
Approx.
(mH/km)

Resistance
at 20 oC
(Ohm/km)

Unshielded pair/quad 0.75 mm2

55

0.75

24.8

Unshielded pair/quad 1.5 mm2

65

0.67

12.2

301

Copper
content
approx.
(kg/km)

Shipline BXOI Fire resistant instrument cable 250V


Halogen free shipcable
Ordering information
Part
number
125560
127041
125766
127139
125767
125840

Description

EAN No.
KDN
8711401030931
8711401058065
8711401030924
8711401062147
8711401030955
8711401031655

BXOI fr 250V gn# 1x2x0,75 mm2


BXOI fr 250V gn# 1x2x1,5 mm2
BXOI fr 250V gn# 2x2x0,75 mm2
BXOI fr 250V gn# 4x2x0,75 mm2
BXOI fr 250V gn# 7x2x0,75 mm2
BXOI fr 250V gn# 10x2x0,75 mm2

Stock
Item
No
No
No
No
No
No

Ambient temperature correction factors


Ambient temp. C
Rating factor

25
1.22

30
1.17

35
1.12

40
1.06

45
1.00

50
0.94

55
0.87

60
0.79

65
0.71

70
0.61

75
0.50

Installation recommendations
Minimum bending radius
during installation
8xD

Minimum bending radius


fixed installed
6xD

Maximum tensile load


during installation
50 N * total cross section
conductors

Subject to change without notice

302

Minimum installation
temperature
-20 C

TFOI 12kV(2).doc
21.06.2006 14:02
Page 1 of 2

Shipline TFOI 6/10(12)kV MV Power cable


Flame retardant halogen-free medium
voltage (MV) power cable. Braided

TFOI 6/10(12) kV
XLPE/EPR/TCWB/PO

Operating temperature
Operating Voltage

: 90C
: 6/10(12) kV

Standards applied

Application
Armoured cable for fixed installation in ships where cable
protection is required. Medium Voltage power distribution. Can be
installed and operated both indoors and outdoors.

IEC 60092-354
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 600754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Conductor screen
semiconductive
Insulation

Annealed stranded circular copper, IEC 60228 class 2


Extruded semiconductive layer
T

Insulation screen
semicoductive
Lay up / Shielding
Inner covering
Tape over bedding
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Outer sheath colour

F
O

Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)


Extruded semiconductive layer. A copper tape is applied as a metallic
screen above the insulation screen. The thickness of the copper tape is 0,1
mm.
Cores are laid up together. Cores are identified by White, Black or Red
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoplastic compound
Additional tape may be applied
Tinned copper wire braid
Additional tape may be applied
Flame retardant halogen-free thermoplastic compound, SHF1
E.g. "meter" "year" DRAKA NORSK KABEL TFOI 6/10(12)KV 3 x 95/50
mm2 IEC 60332-3-22 ShipLine
Red

www.drakaMOG.com
303

TFOI 12kV(2).doc
21.06.2006 14:02
Page 2 of 2

Shipline TFOI 6/10(12)kV MV Power cable


Range and dimensions
Cross Cross
Number
Conductor
section section
of
Diameter,
core,
screen,
elements
mm
mm
mm
1
95
10
11.2

Thickness
Insulation Thickness Diameter Diameter
Outer
Thickness, Bedding, bedding, Braid
Sheath,
mm
mm
mm
Wire, mm
mm
3.4
1
22.5 1 0.3
1.7

150

10

14.2

3.4

26 1

0.3

1.8

95

50

11.2

3.4

1.8

48.5 2

0.5

2.6

120

60

12.6

3.4

1.8

52.5
2.5

0.6

2.7

Diameter
outer
sheath,
mm
27 1
30.5
1.5
55.5
2.5

Weight
of Cable
Approx.
(Kg/Km)
1640

Copper
content
Approx.
(kg/km)
1094

2220

1542

6060

3390

60 3

7270

4291

Ordering information
Part number
838504
838506
838525
838526

Description
TFOI 6/10(12)KV 1X 95/10mm2
TFOI 6/10(12)KV 1X 150/10mm2
TFOI 6/10(12)kV 3X 95/50mm
TFOI 6/10(12)kV 3X 120/60mm

EAN No. DNK


7021528385045
7021528385069
7021528385250
7021528385267

EL No.
-

KDN Part number


-

EAN no. KDN


-

Electrical values power cables


Number Cross Cross Conductor
Max.
of
section section
type 2
conductor
elements core, screen,
resistance
mm
mm
at 20C,
Ohm/km
1
1
3
3

95
150
95
120

10
10
50
60

SCC
SCC
SCC
SCC

0.193
0.124
0.193
0.153

Max.
conductor
resistance
at 90C,
Ohm/km
0.246
0.158
0.246
0.195

Reactance Reactance Capacitans


at 50Hz,
at 60Hz, per phase,
Ohm/km
Ohm/km
nF/km

0.119
0.113
0.091
0.088

0.143
0.136
0.109
0.106

300
360
300
330

Current
rating
IEC
60092352,
Ampere
293
389
205
237

Short
circuit
rating 1
second,
Ampere
16800
21000
4900
9800

Ambient temperature correction factors


Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
15 x D

Minimum Bending Radius


Fixed Installed
9xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
304

Minimum Installation
Temperature
-10C

Shipline TI Power cable 0.6/1 kV


Halogen free shipcable

TI 0.6/1kV
XLPE/SHF1
Max. conductor temp. : 90C
Nominal voltage
: 0.6/1 kV

Application

Standards applied

Unarmoured cable for fixed installations on ships


where cable protection is not required.
For power, control and lighting systems.
Can be installed and operated both indoors and
outdoors.

Design
Conductor
Insulation
Sheath
Fire retardant
Halogen Free
Low smoke

- IEC 60092-353
- IEC 60228 class 2
- IEC 60092-351
- IEC 60092-359
- IEC 60332-3-22 (cat. A)
- IEC 60754-1,2
- IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector
shaped conductors, other types circular conductors

Conductor
Insulation

Crosslinked polyethylene, XLPE

Lay up

Polyester tape(s) may be applied over the laid up cores

Inner covering

No inner covering

Outer sheath
Marking text
Outer sheath
colour

Flame retardant halogen free thermoplastic compound, SHF1


DRAKA {factory code} TI 0,6/1 kV ..x.. mm2 IEC60332-3-22
ShipLine {year of manufacture} {length indication (meter)}
Black

305

Shipline TI Power cable 0.6/1 kV


Halogen free shipcable
Core identification
Single core
Two cores
Three cores
Four cores
Five cores
Multi core

Black
Blue - Brown
Brown - Black - Grey
Blue - Brown - Black - Grey
Blue - Brown - Black - Grey - Black
White with black numbers

with yellow/green (optional)


Two cores + earth (3G)
Three cores + earth (4G)
Four cores + earth (5G)

Yellow/green - Blue - Brown


Yellow/green - Brown - Black - Grey
Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

Weight
approx.

10

5.4

0.7

1.0

7.5

16

130

85

6.4

0.7

1.0

8.5

190

136

25

35

8.1

0.9

1.1

10.4

295

217

9.4

0.9

1.1

11.7

380

300

50

10.8

1.0

1.2

13.3

510

405

70

12.8

1.1

1.3

15.5

720

587

95

14.7

1.1

1.3

17.4

970

819

120

16.5

1.2

1.4

19.4

1220

1040

150

18.4

1.4

1.5

21.5

1505

1282

185

20.7

1.6

1.5

23.8

1865

1606

240

23.4

1.7

1.6

26.7

2420

2108

300

26.0

1.8

1.7

29.6

3015

2642

1.5

3.0

0.7

1.1

8.4

80

26

1.5

3.0

0.7

1.1

8.4

80

26

2.5

3.5

0.7

1.1

9.2

100

42

4.0

0.7

1.1

10.3

135

69

(mm)

(kg/km)

Copper
content
approx.
(kg/km)

4.5

0.7

1.2

11.6

185

102

10

5.4

0.7

1.2

13.3

270

170

16

6.4

0.7

1.3

15.6

400

273

3G

1.5

3.0

0.7

1.1

8.8

100

39

3G

2.5

3.5

0.7

1.1

9.8

130

64

3G

4.0

0.7

1.2

11.1

190

104

3G

4.5

0.7

1.2

12.3

250

153

3G

16

6.4

0.7

1.3

16.6

560

410

1.5

3.0

0.7

1.1

8.8

100

39

2.5

3.5

0.7

1.1

9.8

130

64

4.0

0.7

1.2

11.1

190

104

4.5

0.7

1.2

12.3

250

153

10

5.4

0.7

1.3

14.3

380

56

16

6.4

0.7

1.3

16.6

560

410

25

8.1

0.9

1.5

20.7

875

655

306

Shipline TI Power cable 0.6/1 kV


Halogen free shipcable
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

35

9.4

0.9

1.6

23.5

35

1220

904

7.8/12.4

0.9

1.5

20.1

1135

50

917

8.9/14.2

1.0

1.7

22.8

1530

1251

3
3

70

10.5/16.9

1.1

1.8

26.7

2150

1802

95

12.1/19.7

1.1

1.9

30.2

2900

2470

120

13.5/21.9

1.2

2.1

34.0

3675

3152

4G

1.5

3.0

0.7

1.1

9.6

120

52

4G

2.5

3.5

0.7

1.1

10.7

165

85

4G

4.0

0.7

1.2

12.2

240

138

4G

4.5

0.7

1.

13.5

320

204

4G

10

5.4

0.7

1.3

15.7

490

342

4G

16

6.4

0.7

1.4

18.5

740

548

4G
4G

25
35

8.1
9.4

0.9
0.9

1.5
1.7

22.8
26.0

1145
1515

874
1207

1.5

3.0

0.7

1.1

9.6

120

52

2.5

3.5

0.7

1.1

10.7

165

85

4.0

0.7

1.2

12.2

240

138

4.5

0.7

1.2

13.5

320

204

10

5.4

0.7

1.3

15.7

490

342

16

6.4

0.7

1.4

18.5

740

548

25

8.1

0.9

1.5

22.8

1145

874

5G

1.5

3.0

0.7

1.1

10.5

145

66

5G

2.5

3.5

0.7

1.2

11.9

205

106

(mm)

5G

4.5

0.7

1.3

15.0

400

255

5G

16

6.4

0.7

1.5

20.5

920

686

1.5

3.0

0.7

1.1

10.5

145

66

2.5

3.5

0.7

1.2

11.9

205

106

1.5

3.0

0.7

1.2

11.6

180

80

1.5

3.0

0.7

1.2

11.7

195

93

8G

1.5

3.0

0.7

1.2

12.7

225

106

1.5

3.0

0.7

1.2

12.7

225

106

10

1.5

3.0

0.7

1.3

14.8

275

133

12

1.5

3.0

0.7

1.3

15.3

315

160

16

1.5

3.0

0.7

1.4

17.2

410

213

19

1.5

3.0

0.7

1.4

18.1

470

253

24

1.5

3.0

0.7

1.5

21.3

620

320

307

Shipline TI Power cable 0.6/1 kV


Halogen free shipcable
Electrical values
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Conductor
type

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

Reactance
at 50Hz

Reactance
at 60Hz

10

SCC

1.83

2.33

16

SCC

1.15

25

SCC

35

50

70

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)

(Ohm/km)

(Ohm/km)

0.105

0.126

72

1430

1.47

0.098

0.118

96

2285

0.727

0.927

0.096

0.115

127

3575

SCC

0.524

0.669

0.091

0.110

157

5005

SCC

0.387

0.494

0.087

0.105

196

7150

SCC

0.268

0.343

0.085

0.102

242

10010

95

SCC

0.193

0.248

0.082

0.098

293

13585

120

SCC

0.153

0.198

0.081

0.097

339

17160

150

SCC

0.124

0.162

0.081

0.097

389

21450

185

SCC

0.0991

0.131

0.080

0.096

444

26455

240

SCC

0.0754

0.102

0.079

0.094

522

34320

300

SCC

0.0601

0.0831

0.078

0.093

601

42900

1.5

SCC

12.1

15.4

0.104

0.125

20

210

1.5

SCC

12.1

15.4

0.104

0.125

20

210

2.5

SCC

7.41

9.45

0.098

0.118

26

355

SCC

4.61

5.88

0.092

0.110

34

570

SCC

3.08

3.93

0.088

0.106

44

855

10

SCC

1.83

2.33

0.084

0.101

61

1430

16

SCC

1.15

1.47

0.080

0.096

82

2285

3G

1.5

SCC

12.1

15.4

0.104

0.125

20

210

3G

2.5

SCC

7.41

9.45

0.098

0.118

26

355

3G

SCC

4.61

5.88

0.092

0.110

34

570

3G

SCC

3.08

3.93

0.088

0.106

44

855

3G

16

SCC

1.15

1.47

0.080

0.096

82

2285

1.5

SCC

12.1

15.4

0.104

0.125

16

210

2.5

SCC

7.41

9.45

0.098

0.118

21

355

SCC

4.61

5.88

0.092

0.110

28

570

SCC

3.08

3.93

0.088

0.106

36

855

10

SCC

1.83

2.33

0.084

0.100

50

1430

16

SCC

1.15

1.47

0.080

0.096

67

2285

25

SCC

0.727

0.927

0.080

0.097

89

3575

35

SCC

0.524

0.669

0.078

0.093

110

5005

35

SSC

0.524

0.669

0.074

0.089

110

5005

50

SSC

0.387

0.494

0.071

0.085

137

7150

70

SSC

0.268

0.343

0.070

0.084

169

10010

95

SSC

0.193

0.248

0.069

0.083

205

13585

120

SSC

0.153

0.198

0.068

0.082

237

17160

4G

1.5

SCC

12.1

15.4

0.112

0.134

16

210

4G

2.5

SCC

7.41

9.45

0.105

0.126

21

355

4G

SCC

4.61

5.88

0.099

0.119

28

570

4G

SCC

3.08

3.93

0.095

0.114

36

855

4G

10

SCC

1.83

2.33

0.091

0.109

50

1430

4G

16

SCC

1.15

1.47

0.087

0.105

67

2285

4G
4G

25
35

SCC
SCC

0.727
0.524

0.927
0.669

0.088
0.088

0.105
0.105

89
110

3575
5005

1.5

SCC

12.1

15.4

0.112

0.134

14

210

2.5

SCC

7.41

9.45

0.105

0.126

18

355

SCC

4.61

5.88

0.099

0.119

25

570

SCC

3.08

3.93

0.095

0.114

32.5

855

308

Shipline TI Power cable 0.6/1 kV


Halogen free shipcable
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Conductor
type

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

Reactance
at 50Hz

Reactance
at 60Hz

10

SCC

1.83

2.33

16

SCC

1.15

25

SCC

5G

1.5

5G

2.5

5G

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)

(Ohm/km)

(Ohm/km)

0.091

0.109

45

1430

1.47

0.087

0.105

60

2285

0.727

0.927

0.088

0.105

80

3575

SCC

12.1

15.4

0.114

0.137

14

210

SCC

7.41

9.45

0.108

0.130

18

355

SCC

3.08

3.93

0.098

0.118

32.5

855

5G

16

SCC

1.15

1.47

0.090

0.108

60

2285

1.5

SCC

12.1

15.4

0.114

0.137

13

210

2.5

SCC

7.41

9.45

0.108

0.130

16.5

355

1.5

SCC

12.1

15.4

0.104

0.125

12.5

210
210

1.5

SCC

12.1

15.4

0.104

0.125

12

8G

1.5

SCC

12.1

15.4

0.104

0.125

12

210

1.5

SCC

12.1

15.4

0.104

0.125

11.5

210

10

1.5

SCC

12.1

15.4

0.104

0.125

10.5

210

12

1.5

SCC

12.1

15.4

0.104

0.125

10

210

16

1.5

SCC

12.1

15.4

0.104

0.125

210

19

1.5

SCC

12.1

15.4

0.104

0.125

8.5

210

24

1.5

SCC

12.1

15.4

0.104

0.125

7.5

210

SCC = Stranded Circular Conductor


SSC = Stranded Sector Conductor

Ordering information
Part
number
124831
124832
124833
124834
124835
124836
124837
124838
125521
124839
124840
127344
124841
128486
124842
124843
124844
124845
124846
124850
125526
127213
127215
127472
124849
124851
124852
124853
124854
124855
124856
124857
125838

Description
TI 0,6/1kV black 1x10 mm2
TI 0,6/1kV black 1x16 mm2
TI 0,6/1kV black 1x25 mm2
TI 0,6/1kV black 1x35 mm2
TI 0,6/1kV black 1x50 mm2
TI 0,6/1kV black 1x70 mm2
TI 0,6/1kV black 1x95 mm2
TI 0,6/1kV black 1x120 mm2
TI 0,6/1kV black 1x150 mm2
TI 0,6/1kV black 1x185 mm2
TI 0,6/1kV black 1x240 mm2
TI 0,6/1kV black 1x300 mm2
TI 0,6/1kV black 2x1,5 mm2
TI 0,6/1kV red 2x1,5 mm2
TI 0,6/1kV black 2x2,5 mm2
TI 0,6/1kV black 2x4 mm2
TI 0,6/1kV black 2x6 mm2
TI 0,6/1kV black 2x10 mm2
TI 0,6/1kV black 2x16 mm2
TI 0,6/1kV black 3G1,5 mm2
TI 0,6/1kV black 3G2,5 mm2
TI 0,6/1kV black 3G4 mm2
TI 0,6/1kV black 3G6 mm2
TI 0,6/1kV black 3G16 mm2
TI 0,6/1kV black 3x1,5 mm2
TI 0,6/1kV black 3x2,5 mm2
TI 0,6/1kV black 3x4 mm2
TI 0,6/1kV black 3x6 mm2
TI 0,6/1kV black 3x10 mm2
TI 0,6/1kV black 3x16 mm2
TI 0,6/1kV black 3x25 mm2
TI 0,6/1kV black 3x35 mm2
TI 0,6/1kV black 3x35 mm2 shaped

EAN No.
KDN
8711401093066
8711401088925
8711401093103
8711401089113
8711401093097
8711401089137
8711401089144
8711401093110
8711401089724
8711401093127
8711401093134
8711401093707
8711401093141
8711401111784
8711401093165
8711401093172
8711401093189
8711401093196
8711401093219
8711401093233
8711401089175
8711401093677
8711401093684
8711401101433
8711401093226
8711401093240
8711401089748
8711401093257
8711401093264
8711401093271
8711401093288
8711401093295
8711401093639

309

Stock
Item
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
No
Yes
Yes
Yes
No
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No

Shipline TI Power cable 0.6/1 kV


Halogen free shipcable
Part
number
124858
124859
124860
124861
124864
127212
127214
127216
127345
127416
127343
128332
124863
124865
124866
124867
124868
124869
127200
124871
124873
128420
127997
124870
124872
124874
124876
126447
124877
124878
124879
124880
124881
124882

Description

EAN No.
KDN
8711401093318
8711401093325
8711401093332
8711401093349
8711401089168
8711401093660
8711401089182
8711401089199
8711401093714
8711401100283
8711401093691
8711401106322
8711401093356
8711401093370
8711401093387
8711401093394
8711401093424
8711401093431
8711401093653
8711401089731
8711401093509
8711401107893
8711401102010
8711401093448
8711401093462
8711401093516
8711401093523
8711401093646
8711401093547
8711401093561
8711401093578
8711401093592
8711401093615
8711401093622

TI 0,6/1kV black 3x50 mm2 shaped


TI 0,6/1kV black 3x70 mm2 shaped
TI 0,6/1kV black 3x95 mm2 shaped
TI 0,6/1kV black 3x120 mm2 shaped
TI 0,6/1kV black 4G1,5 mm2
TI 0,6/1kV black 4G2,5 mm2
TI 0,6/1kV black 4G4 mm2
TI 0,6/1kV black 4G6 mm2
TI 0,6/1kV black 4G10 mm2
TI 0,6/1kV black 4G16 mm2
TI 0,6/1kV black 4G25 mm2
TI 0,6/1kV black 4G35 mm2
TI 0,6/1kV black 4x1,5 mm2
TI 0,6/1kV black 4x2,5 mm2
TI 0,6/1kV black 4x4 mm2
TI 0,6/1kV black 4x6 mm2
TI 0,6/1kV black 4x10 mm2
TI 0,6/1kV black 4x16 mm2
TI 0,6/1kV black 4x25 mm2
TI 0,6/1kV black 5G1,5 mm2
TI 0,6/1kV black 5G2,5 mm2
TI 0,6/1kV black 5G6 mm2
TI 0,6/1kV black 5G16 mm2
TI 0,6/1kV black 5x1,5 mm2
TI 0,6/1kV black 5x2,5 mm2
TI 0,6/1kV black 6x1,5 mm2
TI 0,6/1kV black 7x1,5 mm2
TI 0,6/1kV black 8G1,5 mm2
TI 0,6/1kV black 8x1,5 mm2
TI 0,6/1kV black 10x1,5 mm2
TI 0,6/1kV black 12x1,5 mm2
TI 0,6/1kV black 16x1,5 mm2
TI 0,6/1kV black 19x1,5 mm2
TI 0,6/1kV black 24x1,5 mm2

Stock
Item
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes

Ambient temperature correction factors


Ambient temp. C
Rating factor

25
1.22

30
1.17

35
1.12

40
1.06

45
1.00

50
0.94

55
0.87

60
0.79

65
0.71

70
0.61

75
0.50

Installation recommendations
Minimum bending radius
during installation
8xD

Minimum bending radius


fixed installed
6xD

Maximum tensile load


during installation
50 N * total cross section
conductors

Subject to change without notice

310

Minimum installation
temperature
-20 C

Shipline TI(c) Control cable 1000V


Halogen free shipcable

TI(c) 0.6/1kV
XLPE/OSCR/SHF1
Max. conductor temp. : 90C
Nominal voltage
: 1000V

Application

Standards applied

Unarmoured cable for fixed installations on ships


where cable protection is not required.
For control systems.
Can be installed and operated both indoors and
outdoors.

Design
Conductor
Insulation
Sheath
Fire retardant
Halogen Free
Low smoke

- IEC 60092-353
- IEC 60228 class 2
- IEC 60092-351
- IEC 60092-359
- IEC 60332-3-22 (cat. A)
- IEC 60754-1,2
- IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded circular copper conductors

Conductor
Insulation

Crosslinked polyethylene, XLPE

Lay up

Over the laid up cores one or more tapes may be applied

Inner covering

No inner covering

Shield

Copper backed polyester tape with a tinned copper drain wire


of 1,5 mm2

Outer sheath

Flame retardant halogen free thermoplastic compound, SHF1

Marking text
Outer sheath
colour

DRAKA {factory code} TI 0,6/1 kV ..x.. mm2 IEC60332-3-22


ShipLine ** {year of manufacture} {length indication (meter)}
Black

311

Shipline TI(c) Control cable 1000V


Halogen free shipcable
Core identification
White cores with black numbers

Range and dimensions


Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

1.5

1.5

3.0

0.7

1.1

8.7

2.5

1.5

95

38

3.4

0.7

1.1

9.6

120

54

1.5

2.5

1.5

3.0

0.7

1.1

9.2

120

51

1.5

3.4

0.7

1.1

10.1

155

75

4
5

1.5

1.5

3.0

0.7

1.1

10.0

145

64

1.5

1.5

3.0

0.7

1.1

10.8

170

77

1.5

1.5

3.0

0.7

1.2

12.0

215

104

12

1.5

1.5

3.0

0.7

1.3

15.6

340

170

19

1.5

1.5

3.0

0.7

1.4

18.4

495

262

32

1.5

1.5

3.0

0.7

1.6

23.8

805

434

Reactance
at 50Hz

Reactance
at 60Hz

(mm)

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

Electrical values
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Conductor
type

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)

(Ohm/km)

(Ohm/km)

1.5

1.5

SCC

12.1

15.4

0.103

0.124

20

2.5

1.5

SCC

7.41

9.45

0.112

0.135

26

355

1.5

1.5

SCC

12.1

15.4

0.103

0.124

16

210

210

2.5

1.5

SCC

7.41

9.45

0.112

0.135

21

355

1.5

1.5

SCC

12.1

15.4

0.111

0.133

14

210

1.5

1.5

SCC

12.1

15.4

0.113

0.136

13

210

1.5

1.5

SCC

12.1

15.4

0.103

0.124

12

210

12

1.5

1.5

SCC

12.1

15.4

0.103

0.124

10

210

19

1.5

1.5

SCC

12.1

15.4

0.103

0.124

8.5

210

32

1.5

1.5

SCC

12.1

15.4

0.103

0.124

7.5

210

SCC = Stranded Circular Conductor

312

Shipline TI(c) Control cable 1000V


Halogen free shipcable
Ordering information
Part
number
127228
127293
127341
127391
127387
127388
127291
127292
127389
127390

Description

EAN No.
KDN
8711401072900
8711401088222
8711401088499
8711401099433
8711401099037
8711401099051
8711401085528
8711401087768
8711401099730
8711401099761

TI(c) 0,6/1kV black 2x1,5 mm2


TI(c) 0,6/1kV black 2x2,5 mm2
TI(c) 0,6/1kV black 3x1,5 mm2
TI(c) 0,6/1kV black 3x2,5 mm2
TI(c) 0,6/1kV black 4x1,5 mm2
TI(c) 0,6/1kV black 5x1,5 mm2
TI(c) 0,6/1kV black 7x1,5 mm2
TI(c) 0,6/1kV black 12x1,5 mm2
TI(c) 0,6/1kV black 19x1,5 mm2
TI(c) 0,6/1kV black 32x1,5 mm2

Stock
Item
No
No
No
No
No
No
No
No
No
No

Ambient temperature correction factors


Ambient temp. C
Rating factor

25
1.22

30
1.17

35
1.12

40
1.06

45
1.00

50
0.94

55
0.87

60
0.79

65
0.71

70
0.61

75
0.50

Installation recommendations
Minimum bending radius
during installation
8xD

Minimum bending radius


fixed installed
6xD

Maximum tensile load


during installation
50 N * total cross section
conductors

Subject to change without notice

313

Minimum installation
temperature
-20 C

Shipline TXOI Power cable 0.6/1 kV


Braided halogen free shipcable

TXOI 0.6/1kV
XLPE/TCWB/SHF1
Max. conductor temp. : 90C
Nominal voltage
: 0.6/1 kV

Application

Standards applied

Armoured cable for fixed installations on ships


where cable protection is required.
For power, control and lighting systems.
Can be installed and operated both indoors and
outdoors.

Design
Conductor
Insulation
Sheath
Flame retardant
Halogen Free
Low smoke

- IEC 60092-353
- IEC 60228 class 2
- IEC 60092-351
- IEC 60092-359
- IEC 60332-3-22 (cat. A)
- IEC 60754-1,2
- IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector
shaped conductors, other types circular conductors

Conductor
Insulation

Crosslinked polyethylene, XLPE


Polyester tape(s) may be applied over the laid up cores

Lay up
Inner covering

No inner covering

Armour/screen

Tinned copper wire braid

Outer sheath

Flame retardant halogen free thermoplastic compound, SHF1

Marking text
Outer sheath
colour

DRAKA {factory code} TXOI 0,6/1 kV ..x../.. mm2 IEC60332-3-22


ShipLine {year of manufacture} {length indication (meter)}
Black

314

Shipline TXOI Power cable 0.6/1 kV


Braided halogen free shipcable
Core identification
Single core
Two cores
Three cores
Four cores
Five cores
Multi core

Black
Blue - Brown
Brown - Black - Grey
Blue - Brown - Black - Grey
Blue - Brown - Black - Grey - Black
White with black numbers

with yellow/green (optional)


Two cores + earth (3G)
Three cores + earth (4G)
Four cores + earth (5G)

Yellow/green - Blue - Brown


Yellow/green - Brown - Black - Grey
Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

16

2.5

6.4

0.7

0.2

1.1

9.8

25

8.1

245

174

0.9

0.2

1.2

11.7

355

264

35

50

9.4

0.9

0.2

1.2

13.0

455

353

10.8

1.0

0.3

1.3

15.0

620

70

494

12.8

1.1

0.3

1.4

17.2

850

95

691

10

14.7

1.1

0.3

1.4

19.1

1115

936

1
1

120

10

16.5

1.2

0.3

1.5

21.1

1385

1174

150

10

18.4

1.4

0.3

1.6

23.2

1690

1435

185

10

20.7

1.6

0.3

1.6

25.5

2065

1769

240

10

23.4

1.7

0.3

1.7

28.4

2640

2292

300

16

26.0

1.8

0.3

1.8

31.3

3260

2845

1.5

2.5

3.0

0.7

0.2

1.1

9.3

120

62

2.5

2.5

3.5

0.7

0.2

1.1

10.1

150

83

4.0

0.7

0.2

1.2

11.4

195

115

4.5

0.7

0.3

1.2

12.9

275

180

10

10

5.4

0.7

0.3

1.3

14.9

385

267

16

16

6.4

0.7

0.3

1.4

17.6

595

445

25

16

8.1

0.9

0.4

1.5

21.3

820

614

3G

1.5

2.5

3.0

0.7

0.2

1.1

9.8

145

78

3G

2.5

2.5

3.5

0.7

0.2

1.1

10.7

180

105

1.5

2.5

3.0

0.7

0.2

1.1

9.8

145

78

2.5

2.5

3.5

0.7

0.2

1.1

10.7

180

105

4.0

0.7

0.2

1.2

12.0

245

151

4.5

0.7

0.3

1.3

13.8

345

233

10

10

5.4

0.7

0.3

1.3

15.7

490

352

16

16

6.4

0.7

0.4

1.4

18.6

755

582

25

16

8.1

0.9

0.4

1.6

22.7

1095

842

35

16

9.4

0.9

0.3

1.6

24.9

1340

1073

50

25

8.9/14.3

1.0

0.4

1.6

24.8

1820

1508

70

35

10.5/16.9

1.1

0.6

2.0

29.7

2575

2161

95

50

12.1/19.7

1.1

0.6

2.1

33.1

3435

2943

(mm)

315

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

Shipline TXOI Power cable 0.6/1 kV


Braided halogen free shipcable
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

120

25

13.5/21.9

1.2

0.4

2.2

36.0

120

60

4070

3500

13.5/21.9

1.2

0.4

2.3

37.8

4470

150

3863

25

15.2/24.7

1.4

0.4

2.3

39.1

4945

4269

150

70

15.2/24.7

1.4

0.4

2.4

40.9

5435

4722

4G

1.5

2.5

3.0

0.7

0.2

1.1

10.5

170

93

4G

2.5

2.5

3.5

0.7

0.2

1.2

11.8

225

131

1.5

2.5

3.0

0.7

0.2

1.1

10.5

170

93

2.5

2.5

3.5

0.7

0.2

1.2

11.8

225

131

4.0

0.7

0.3

1.3

13.7

335

217

4.5

0.7

0.3

1.3

15.0

425

293

10

10

5.4

0.7

0.3

1.4

17.3

625

455

16

16

6.4

0.7

0.4

1.5

20.5

935

719

25

16

8.1

0.9

0.3

1.6

24.4

1345

1043

35

16

9.4

0.9

0.3

1.7

27.5

1715

1384

70

35

11.5/15.5

1.1

0.4

2.1

32.8

3250

2746
3783

(mm)

95

50

13.3/18.0

1.1

0.6

2.2

37.3

4390

1.5

2.5

3.0

0.7

0.2

1.2

11.7

205

111

2.5

3.5

0.7

0.2

1.2

12.8

265

158

1.5

3.0

0.7

0.2

1.2

12.7

240

132

1.5

3.0

0.7

0.2

1.2

12.7

260

145

1.5

3.0

0.7

0.2

1.2

15.5

340

209

10

1.5

3.0

0.7

0.3

1.3

16.2

390

231

12

1.5

3.0

0.7

0.3

1.4

16.9

440

261

16

1.5

3.0

0.7

0.3

1.4

18.6

550

334

19

1.5

3.0

0.7

0.3

1.5

19.7

620

376

24

1.5

10

3.0

0.7

0.3

1.6

22.9

800

468

Reactance
at 50Hz

Reactance
at 60Hz

Electrical values
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Conductor
type

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)

(Ohm/km)

(Ohm/km)

16

2.5

SCC

1.15

1.47

0.107

0.128

96

2285

25

SCC

0.727

0.927

0.103

0.124

127

3575

35

SCC

0.524

0.669

0.098

0.118

157

5005

50

SCC

0.387

0.494

0.095

0.114

196

7150

70

SCC

0.268

0.343

0.092

0110

242

10010

95

10

SCC

0.193

0.248

0.088

0.106

293

13585

120

10

SCC

0.153

0.198

0.086

0.103

339

17160

150

10

SCC

0.124

0.162

0.085

0.103

389

21450

185

10

SCC

0.0991

0.131

0.085

0.101

444

26455

240

10

SCC

0.0754

0.102

0.082

0.099

522

34320

300

16

SCC

0.0601

0.0831

0.081

0.098

601

42900

1.5

2.5

SCC

12.1

15.4

0.104

0.125

20

210

2.5

2.5

SCC

7.41

9.45

0.098

0.118

26

355

SCC

4.61

5.88

0.092

0.110

34

570

SCC

3.08

3.93

0.088

0.106

44

855

10

10

SCC

1.83

2.33

0.084

0.100

61

1430

16

16

SCC

1.15

1.47

0.080

0.096

82

2285

316

Shipline TXOI Power cable 0.6/1 kV


Braided halogen free shipcable
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Conductor
type

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

Reactance
at 50Hz

Reactance
at 60Hz

(Ohm/km)

(Ohm/km)

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)

25

16

SCC

0.727

0.927

0.080

0.097

108

3575

3G

1.5

2.5

SCC

12.1

15.4

0.104

0.125

20

210

3G

2.5

2.5

SCC

7.41

9.45

0.098

0.118

26

355

1.5

2.5

SCC

12.1

15.4

0.104

0.125

16

210

2.5

2.5

SCC

7.41

9.45

0.098

0.118

21

355

SCC

4.61

5.88

0.092

0.110

28

570

SCC

3.08

3.93

0.088

0.106

36

855

10

10

SCC

1.83

2.33

0.084

0.100

50

1430

16

16

SCC

1.15

1.47

0.080

0.096

67

2285

25

16

SCC

0.727

0.927

0.080

0.097

89

3575

35

16

SCC

0.524

0.669

0.078

0.093

110

5005

50

25

SSC

0.387

0.494

0.071

0.085

137

7150

70

35

SSC

0.268

0.343

0.070

0.084

169

10010

95

50

SSC

0.193

0.248

0.069

0.083

205

13585

120

25

SSC

0.153

0.198

0.068

0.082

237

17160

120

60

SSC

0.153

0.198

0.068

0.082

237

17160

150

25

SSC

0.124

0.162

0.068

0.082

272

21450

150

70

SSC

0.124

0.162

0.068

0.082

272

21450

4G

1.5

2.5

SCC

12.1

15.4

0.112

0.134

16

210

4G

2.5

2.5

SCC

7.41

9.45

0.105

0.126

21

355

1.5

2.5

SCC

12.1

15.4

0.112

0.134

14

210

2.5

2.5

SCC

7.41

9.45

0.105

0.126

18

355

SCC

4.61

5.88

0.099

0.119

25

570

SCC

3.08

3.93

0.095

0.114

32.5

855

10

10

SCC

1.83

2.33

0.091

0.109

45

1430

16

16

SCC

1.15

1.47

0.087

0.105

60

2285

25

16

SCC

0.727

0.927

0.088

0.105

80

3575

35

16

SCC

0.524

0.669

0.085

0.102

98.5

5005

70

35

SSC

0.268

0.343

0.079

0.094

152

10010

95

50

SSC

0.193

0.248

0.077

0.093

184.5

13585

1.5

2.5

SCC

12.1

15.4

0.114

0.137

13

210

2.5

SCC

7.41

9.45

0.122

0.147

16.5

355

1.5

SCC

12.1

15.4

0.104

0.125

12.5

210

1.5

SCC

12.1

15.4

0.104

0.125

12

210
210

1.5

SCC

12.1

15.4

0.104

0.125

11.5

10

1.5

SCC

12.1

15.4

0.104

0.125

10.5

210

12

1.5

SCC

12.1

15.4

0.104

0.125

10

210

16

1.5

SCC

12.1

15.4

0.104

0.125

210

19

1.5

SCC

12.1

15.4

0.104

0.125

8.5

210

24

1.5

10

SCC

12.1

15.4

0.104

0.125

7.5

210

SCC = Stranded Circular Conductor


SSC = Stranded Sector Conductor

317

Shipline TXOI Power cable 0.6/1 kV


Braided halogen free shipcable

Ordering information
Part
number
124884
124885
124886
124887
124888
124889
124890
124891
124892
124893
128768
124894
124895
124896
124897
124898
124899
128004
127202
127198
124900
124901
124902
124903
124904
124905
124906
124907
124908
124909
124910
127205
128399
127347
128400
127203
127199
124913
124914
124915
124916
124917
124918
124919
127411
128334
127346
124920
124921
126759
124924
126760
124926
124927
124928
124929
124930

Description
TXOI 0,6/1kV black 1x16/2,5 mm2
TXOI 0,6/1kV black 1x25/4 mm2
TXOI 0,6/1kV black 1x35/4 mm2
TXOI 0,6/1kV black 1x50/6 mm2
TXOI 0,6/1kV black 1x70/6 mm2
TXOI 0,6/1kV black 1x95/10 mm2
TXOI 0,6/1kV black 1x120/10 mm2
TXOI 0,6/1kV black 1x150/10 mm2
TXOI 0,6/1kV black 1x185/10 mm2
TXOI 0,6/1kV black 1x240/10 mm2
TXOI 0,6/1kV black 1x300/16 mm2
TXOI 0,6/1kV black 2x1,5/2,5 mm2
TXOI 0,6/1kV black 2x2,5/2,5 mm2
TXOI 0,6/1kV black 2x4/4 mm2
TXOI 0,6/1kV black 2x6/6 mm2
TXOI 0,6/1kV black 2x10/10 mm2
TXOI 0,6/1kV black 2x16/16 mm2
TXOI 0,6/1kV black 2x25/16 mm2
TXOI 0,6/1kV black 3G1,5/2,5 mm2
TXOI 0,6/1kV black 3G2,5/2,5 mm2
TXOI 0,6/1kV black 3x1,5/2,5 mm2
TXOI 0,6/1kV black 3x2,5/2,5 mm2
TXOI 0,6/1kV black 3x4/4 mm2
TXOI 0,6/1kV black 3x6/6 mm2
TXOI 0,6/1kV black 3x10/10 mm2
TXOI 0,6/1kV black 3x16/16 mm2
TXOI 0,6/1kV black 3x25/16 mm2
TXOI 0,6/1kV black 3x35/16 mm2
TXOI 0,6/1kV black 3x50/25 mm2 shaped
TXOI 0,6/1kV black 3x70/35 mm2 shaped
TXOI 0,6/1kV black 3x95/50 mm2 shaped
TXOI 0,6/1kV black 3x120/25 mm2 shaped
TXOI 0,6/1kV black 3x120/60 mm2 shaped
TXOI 0,6/1kV black 3x150/25 mm2 shaped
TXOI 0,6/1kV black 3x150/70 mm2 shaped
TXOI 0,6/1kV black 4G1,5/2,5 mm2
TXOI 0,6/1kV black 4G2,5/2,5 mm2
TXOI 0,6/1kV black 4x1,5/2,5 mm2
TXOI 0,6/1kV black 4x2,5/2,5 mm2
TXOI 0,6/1kV black 4x4/6 mm2
TXOI 0,6/1kV black 4x6/6 mm2
TXOI 0,6/1kV black 4x10/10 mm2
TXOI 0,6/1kV black 4x16/16 mm2
TXOI 0,6/1kV black 4x25/16 mm2
TXOI 0,6/1kV black 4x35/16 mm2
TXOI 0,6/1kV black 4x70/35 mm2 shaped
TXOI 0,6/1kV black 4x95/50 mm2 shaped
TXOI 0,6/1kV black 5x1,5/2,5 mm2
TXOI 0,6/1kV black 5x2,5/4 mm2
TXOI 0,6/1kV black 6x1,5/4 mm2
TXOI 0,6/1kV black 7x1,5/4 mm2
TXOI 0,6/1kV black 8x1,5/6 mm2
TXOI 0,6/1kV black 10x1,5/6 mm2
TXOI 0,6/1kV black 12x1,5/6 mm2
TXOI 0,6/1kV black 16x1,5/6 mm2
TXOI 0,6/1kV black 19x1,5/6 mm2
TXOI 0,6/1kV black 24x1,5/10 mm2

EAN No.
KDN
8711401093745
8711401093752
8711401089212
8711401093783
8711401089236
8711401093790
8711401093813
8711401088659
8711401093820
8711401093837
8711401122445
8711401093844
8711401093851
8711401093875
8711401093882
8711401093899
8711401093950
8711401102133
8711401094421
8711401088666
8711401089311
8711401093967
8711401089410
8711401093974
8711401093981
8711401088673
8711401089717
8711401094018
8711401088680
8711401094230
8711401088697
8711401094452
8711401107626
8711401093035
8711401107633
8711401094445
8711401094414
8711401089373
8711401094247
8711401094254
8711401094261
8711401094278
8711401094285
8711401094292
8711401100160
8711401106339
8711401089830
8711401094308
8711401094339
8711401045935
8711401089380
8711401045942
8711401094346
8711401094353
8711401094377
8711401094391
8711401094407

318

Stock
Item
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
No
No
No
No
No
No
Yes
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
Yes
No
No
Yes
No
Yes
Yes
No
Yes
No

Shipline TXOI Power cable 0.6/1 kV


Braided halogen free shipcable

Ambient temperature correction factors


Ambient temp. C
Rating factor

25
1.22

30
1.17

35
1.12

40
1.06

45
1.00

50
0.94

55
0.87

60
0.79

65
0.71

70
0.61

75
0.50

Installation recommendations
Minimum bending radius
during installation
8xD

Minimum bending radius


fixed installed
6xD

Maximum tensile load


during installation
50 N * total cross section
conductors

Subject to change without notice

319

Minimum installation
temperature
-20 C

Shipline TXOI Instrumentation cable 250V


Braided halogen free shipcable

TXOI 250V
XLPE/TCWB/SHF1
Max. conductor temp. : 90C
Nominal voltage
: 250V

Application

Standards applied

Armoured cable for fixed installations on ships


where cable protection is required.
For instrumentation and communication systems.
Can be installed and operated both indoors and
outdoors.

Design
Conductor
Insulation
Sheath
Flame retardant
Halogen Free
Low smoke

- IEC 60092-376
- IEC 60228 class 2
- IEC 60092-351
- IEC 60092-359
- IEC 60332-3-22 (cat A)
- IEC 60754-1,2
- IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded circular copper conductors

Conductor
Insulation

Crosslinked polyethylene, XLPE


Numbered white cores twisted in pairs (two pair type may be built up
as a star quad). The pairs are twisted with different lay length to
reduce mutual capacitance. Over the laid up cores one or more tapes
may be applied

Lay up

Inner covering

No inner covering

Armour/screen

Tinned copper wire braid

Outer sheath

Flame retardant halogen free thermoplastic compound, SHF1

Marking text
Outer sheath
colour

DRAKA {factory code} TXOI 250 V .. pair/triple/quad .. mm2


IEC60092-376 IEC60332-3-22 ShipLine {year of manufacture}
{length indication (meter)}
Grey

320

Shipline TXOI Instrumentation cable 250V


Braided halogen free shipcable
Identification of elements
White cores with black numbers
The pairs have the following number identification according to IEC 60092-376
Pair no. 1
Pair no. 2
Pair no. 3
Pair no. 4

core no. 1 and 2


core no. 3 and 4
core no. 5 and 6
etc.

The single triple is identified


with no 1, 2 and 3
1
The single quad cable has the
following identification

4 + 3
2

Range and dimensions


Elements
(pair)
(triple)
(quad)

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

1 pair

0.5

1.8

0.4

0.2

1.0

6.6

1 quad

0.5

65

33

1.8

0.4

0.2

1.0

7.3

85

42

(mm)

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

1 pair

0.75

2.1

0.5

0.2

1.0

9.1

80

41

1 triple

0.75

2.1

0.5

0.2

1.0

7.6

90

47

1 quad

0.75

2.1

0.5

0.2

1.0

8.2

105

53

4 pair

0.75

2.1

0.5

0.2

1.2

12.2

195

100

7 pair

0.75

2.1

0.5

0.2

1.2

14.4

270

145

10 pair

0.75

2.1

0.5

0.3

1.4

17.8

410

239

14 pair

0.75

2.1

0.5

0.3

1.4

19.3

500

291

19 pair

0.75

2.1

0.5

0.3

1.5

21.5

630

373

24 pair

0.75

2.1

0.5

0.3

1.7

25.2

805

473

Electrical values
Type

Capacitance
approx.
(nF/km)

Inductance
Approx.
(mH/km)

Resistance
at 20 oC
(Ohm/km)

Unshielded pair 0.5 mm2

70

0.60

40.4

Unshielded pair 0.75 mm2

65

0.60

26.0

321

Shipline TXOI Instrumentation cable 250V


Braided halogen free shipcable
Ordering information
Part
number
127257
127258
124931
127243
124933
124934
124936
124937
124938
124939
124940

Description
TXOI 250V gy# 1x2x0,5 mm2 s
TXOI 250V gy# 1x4x0,5 mm2 s quad
TXOI 250V gy# 1x2x0,75 mm2 s
TXOI 250V gy# 1x3x0,75 mm2 s
TXOI 250V gy# 1x4x0,75 mm2 s
TXOI 250V gy# 4x2x0,75 mm2 s
TXOI 250V gy# 7x2x0,75 mm2 s
TXOI 250V gy# 10x2x0,75 mm2 s
TXOI 250V gy# 14x2x0,75 mm2 s
TXOI 250V gy# 19x2x0,75 mm2 s
TXOI 250V gy# 24x2x0,75 mm2 s

EAN No.
KDN
8711401094636
8711401094643
8711401094476
8711401072979
8711401094520
8711401094537
8711401094544
8711401094551
8711401094568
8711401094582
8711401094629

Stock
Item
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
No
No

Installation recommendations
Minimum bending radius
during installation
8xD

Minimum bending radius


fixed installed
6xD

Maximum tensile load


during installation
50 N * total cross section
conductors

Subject to change without notice

322

Minimum installation
temperature
-20 C

Shipline Plus TFXI Power cable 0.6/1 kV


Halogen free shipcable

TFXI 0.6/1kV
XLPE/SHF1
Max. conductor temp. : 90C
Nominal voltage
: 0.6/1 kV

Application

Standards applied

Unarmoured cable for fixed installations on ships


where cable protection is not required.
For power, control and lighting systems.
Can be installed and operated both indoors and
outdoors.

Design
Conductor
Insulation
Sheath
Fire retardant
Halogen Free
Low smoke

- IEC 60092-353
- IEC 60228 class 2 and 5
- IEC 60092-351
- IEC 60092-359
- IEC 60332-3-22 (cat. A)
- IEC 60754-1,2
- IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded circular copper conductors, stranded acc IEC
60228 class 2 or flexible acc IEC 60228 class 5

Conductor
Insulation

Crosslinked polyethylene, XLPE


Cores laid up in one or more layers; in case of cables with more
than 5 cores one or more tapes may be applied over the laid up
cores

Lay up

Single core cables no inner covering; 2 5 core cables bedding of


flame retardant halogen free thermoplastic compound SHF1; cables
with more than 5 cores no inner covering

Armour/screen

No armour or screen

Outer sheath

Flame retardant halogen free thermoplastic compound, SHF1

Inner sheath

Marking text
Outer sheath
colour

DRAKA {factory code} TFXI 0,6/1 kV ..x.. mm2 IEC60332-3-22


ShipLine Plus {year of manufacture} {length indication (meter)}
Black

323

Shipline Plus TFXI Power cable 0.6/1 kV


Halogen free shipcable
Core identification
Single core
Two cores
Three cores
Four cores
Five cores
Multi core

Black
Blue - Brown
Brown - Black - Grey
Blue - Brown - Black - Grey
Blue - Brown - Black - Grey - Black
White with black numbers

with yellow/green (optional)


Two cores + earth (3G)
Three cores + earth (4G)
Four cores + earth (5G)

Yellow/green - Blue - Brown


Yellow/green - Brown - Black - Grey
Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)
210

Class 5
1

25

8.4

0.9

1.1

10.7

285

35

9.95

0.9

1.1

12.3

390

303

50

11.75

1.0

1.2

14.3

545

434

70

13.8

1.1

1.3

16.5

750

613

120

17.4

1.2

1.4

20.3

1210

1022

25

8.4

0.9

1.5

21.6

1035

635

35

9.95

0.9

1.6

25.2

1440

916

50

11.75

1.0

1.7

30.5

2100

1308

70

13.8

1.1

1.9

35.3

2885

1850

95

15.3

1.1

2.0

39.1

3715

2452

Class 2
1

10

5.4

0.7

1.0

7.5

130

85

16

6.4

0.7

1.0

8.5

190

136

25

8.1

0.9

1.1

10.4

295

217

35

9.4

0.9

1.1

11.7

380

300

50

10.8

1.0

1.2

13.3

510

405

70

12.8

1.1

1.3

15.5

720

587

95

14.7

1.1

1.3

17.4

970

819

120

16.5

1.2

1.4

19.4

1220

1040

150

18.4

1.4

1.5

21.5

1505

1282

185

20.7

1.6

1.5

23.8

1865

1606

240

23.4

1.7

1.6

26.7

2420

2108

400

29.3

2.0

1.9

33.3

3850

3384

1.5

3.0

0.7

1.0

8.6

110

26

2.5

3.5

0.7

1.1

9.6

150

42

4.0

0.7

1.1

10.7

195

69

4.5

0.7

1.2

12.0

260

102

10

5.4

0.7

1.2

13.7

370

170

16

6.4

0.7

1.3

16.0

540

273

324

Shipline Plus TFXI Power cable 0.6/1 kV


Halogen free shipcable
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

3G

1.5

3.0

0.7

1.1

9.2

3G

2.5

130

39

3.5

0.7

1.1

10.2

175

64

1.5

2.5

3.0

0.7

1.1

9.2

130

39

3.5

0.7

1.1

10.2

175

64

3
3

4.0

0.7

1.1

11.3

235

104

4.5

0.7

1.2

12.7

315

153

10

5.4

0.7

1.3

14.7

465

256

(mm)

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

16

6.4

0.7

1.3

17.0

680

410

25

8.1

0.9

1.5

21.1

1060

655

35

9.4

0.9

1.6

23.9

1390

904

50

10.8

1.0

1.7

28.3

1925

1223

70

12.8

1.1

1.9

33.1

2705

1772

95

14.7

1.1

2.0

37.8

3665

2469

120

16.5

1.2

2.2

42.0

4595

3137

150

18.4

1.4

2.3

46.3

5620

3865

4G

1.5

3.0

0.7

1.1

10.0

155

52

4G

2.5

3.5

0.7

1.1

11.1

205

85

4G

4.5

0.7

1.2

13.9

385

204

1.5

3.0

0.7

1.1

10.0

155

52

2.5

3.5

0.7

1.1

11.1

205

85

4.0

0.7

1.2

12.6

290

138

4.5

0.7

1.2

13.9

385

204

10

5.4

0.7

1.3

16.1

575

342
548

16

6.4

0.7

1.4

18.9

855

5G

1.5

3.0

0.7

1.1

10.9

185

66

5G

2.5

3.5

0.7

1.2

12.3

250

106

1.5

3.0

0.7

1.1

10.9

185

66

2.5

3.5

0.7

1.2

12.3

250

106

1.5

3.0

0.7

1.2

11.6

180

80

1.5

3.0

0.7

1.2

11.7

195

93

8G

1.5

3.0

0.7

1.2

12.7

225

106

1.5

3.0

0.7

1.2

12.7

225

106

10

1.5

3.0

0.7

1.3

14.8

275

133

12

1.5

3.0

0.7

1.3

15.3

315

160

16

1.5

3.0

0.7

1.4

17.2

410

213

19

1.5

3.0

0.7

1.4

18.1

470

253

24

1.5

3.0

0.7

1.5

21.3

620

320

325

Shipline Plus TFXI Power cable 0.6/1 kV


Halogen free shipcable
Electrical values
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Conductor
type

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

Reactance
at 50Hz

Reactance
at 60Hz

(Ohm/km)

(Ohm/km)

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)

Class 5
1

25

SCC

0.78

0.995

0.094

0.113

127

3575

35

SCC

0.554

0.706

0.090

0.107

157

5005

50

SCC

0.386

0.492

0.085

0.102

196

7150

70

SCC

0.272

0.347

0.083

0.100

242

10010

120

SCC

0.161

0.205

0.079

0.095

339

17160

25

SCC

0.78

0.995

0.079

0.095

89

3575

35

SCC

0.554

0.706

0.076

0.092

110

5005

50

SCC

0.386

0.492

0.073

0.087

137

7150

70

SCC

0.272

0.347

0.072

0.086

169

10010

95

SCC

0.206

0.263

0.071

0.085

205

13585

Class 2
1

10

SCC

1.83

2.33

0.105

0.126

72

1430

16

SCC

1.15

1.47

0.098

0.118

96

2285

25

SCC

0.727

0.927

0.096

0.115

127

3575

35

SCC

0.524

0.669

0.091

0.110

157

5005

50

SCC

0.387

0.494

0.087

0.105

196

7150

70

SCC

0.268

0.343

0.085

0.102

242

10010

95

SCC

0.193

0.248

0.082

0.098

293

13585

120

SCC

0.153

0.198

0.081

0.097

339

17160

150

SCC

0.124

0.162

0.080

0.097

389

21450

185

SCC

0.0991

0.131

0.080

0.096

444

26455

240

SCC

0.0754

0.102

00.78

0.094

522

34320

400

SCC

0.047

0.0685

0.078

0.093

670

57200

1.5

SCC

12.1

15.4

0.104

0.125

20

210

2.5

SCC

7.41

9.45

0.098

0.118

26

355

SCC

4.61

5.88

0.092

0.110

34

570

SCC

3.08

3.93

0.088

0.106

44

855

10

SCC

1.83

2.33

0.084

0.100

61

1430

16

SCC

1.15

1.47

0.080

0.096

82

2285

3G

1.5

SCC

12.1

15.4

0.104

0.125

20

210

3G

2.5

SCC

7.41

9.45

0.098

0.118

26

355

1.5

SCC

12.1

15.4

0.104

0.125

16

210

2.5

SCC

7.41

9.45

0.098

0.118

21

355

SCC

4.61

5.88

0.092

0.110

28

570

SCC

3.08

3.93

0.088

0.106

36

855

10

SCC

1.83

2.33

0.084

0.100

50

1430

16

SCC

1.15

1.47

0.080

0.096

67

2285

25

SCC

0.727

0.927

0.080

0.097

89

3575

35

SCC

0.524

0.669

0.078

0.093

110

5005

50

SCC

0.387

0.494

0.074

0.089

137

7150

70

SCC

0.268

0.343

0.073

0.088

169

10010

95

SCC

0.193

0.248

0.072

0.086

205

13585

120

SCC

0.153

0.198

0.070

0.084

237

17160

150

SCC

0.124

0.162

0.071

0.085

272

21450

4G

1.5

SCC

12.1

15.4

0112

0.134

16

210

4G

2.5

SCC

7.41

9.45

0.105

0.126

21

355

4G

SCC

3.08

3.93

0.095

0.114

36

855

326

Shipline Plus TFXI Power cable 0.6/1 kV


Halogen free shipcable
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Conductor
type

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

Reactance
at 50Hz

Reactance
at 60Hz

1.5

SCC

12.1

15.4

2.5

SCC

7.41

SCC

4.61

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)

(Ohm/km)

(Ohm/km)

0.112

0.114

14

9.45

0.105

0.134

18

210

5.88

0.099

0.126

25

355

855

SCC

3.08

3.93

0.095

0.119

32.5

570

10

SCC

1.83

2.33

0.091

0.114

45

855

16

SCC

1.15

1.47

0.087

0.109

60

1430

5G

1.5

SCC

12.1

15.4

0.114

0.105

14

2285

5G

2.5

SCC

7.41

9.45

0.108

0.137

18

210

1.5

SCC

12.1

15.4

0.114

0.130

13

355

2.5

SCC

7.41

9.45

0.108

0.137

16.5

210

1.5

SCC

12.1

15.4

0.104

0.130

12.5

355
210

1.5

SCC

12.1

15.4

0.104

0.125

12

8G

1.5

SCC

12.1

15.4

0.104

0.125

12

210

1.5

SCC

12.1

15.4

0.104

0.125

11.5

210

10

1.5

SCC

12.1

15.4

0.104

0.125

10.5

210

12

1.5

SCC

12.1

15.4

0.104

0.125

10

210

16

1.5

SCC

12.1

15.4

0.104

0.125

210

19

1.5

SCC

12.1

15.4

0.104

0.125

8.5

210

24

1.5

SCC

12.1

15.4

0.104

0.125

7.5

210

SCC = Stranded Circular Conductor

Ordering information
Part
number
128234
128235
128236
128237
128636
128243
128244
128245
128246
128460
128624
128625
128626
128627
128628
128629
128630
128631
128634
128632
128633
128571
125130
125131
125132
125134
125144
125119
126442
126444
125104
125015
125105
125106

Description
TFXI cl5 0,6/1kV black 1x25 mm2
TFXI cl5 0,6/1kV black 1x35 mm2
TFXI cl5 0,6/1kV black 1x50 mm2
TFXI cl5 0,6/1kV black 1x70 mm2
TFXI cl5 0,6/1kV black 1x120 mm2
TFXI cl5 0,6/1kV black 3x25 mm2
TFXI cl5 0,6/1kV black 3x35 mm2
TFXI cl5 0,6/1kV black 3x50 mm2
TFXI cl5 0,6/1kV black 3x70 mm2
TFXI cl5 0,6/1kV black 3x95 mm2

EAN No.
KDN
8711401105431
8711401105462
8711401105493
8711401105523
8711401116505
8711401105547
8711401105592
8711401105622
8711401105639
8711401109170

Stock
Item
N
N
N
N
N
N
N
N
N
N

TFXI 0,6/1kV black 1x10 mm2


TFXI 0,6/1kV black 1x16 mm2
TFXI 0,6/1kV black 1x25 mm2
TFXI 0,6/1kV black 1x35 mm2
TFXI 0,6/1kV black 1x50 mm2
TFXI 0,6/1kV black 1x70 mm2
TFXI 0,6/1kV black 1x95 mm2
TFXI 0,6/1kV black 1x120 mm2
TFXI 0,6/1kV black 1x150 mm2
TFXI 0,6/1kV black 1x185 mm2
TFXI 0,6/1kV black 1x240 mm2
TFXI 0,6/1kV black 1x400 mm2
TFXI 0,6/1kV black 2x1,5 mm2
TFXI 0,6/1kV black 2x2,5 mm2
TFXI 0,6/1kV black 2x4 mm2
TFXI 0,6/1kV black 2x6 mm2
TFXI 0,6/1kV black 2x10 mm2
TFXI 0,6/1kV black 2x16 mm2
TFXI 0,6/1kV black 3G1,5 mm2
TFXI 0,6/1kV black 3G2,5 mm2
TFXI 0,6/1kV black 3x1,5 mm2
TFXI 0,6/1kV black 3x2,5 mm2
TFXI 0,6/1kV black 3x4 mm2
TFXI 0,6/1kV black 3x6 mm2

8711401116475
8711401116482
8711401116499
8711401116512
8711401116529
8711401116543
8711401116550
8711401116567
8711401116598
8711401116574
8711401116581
8711401115850
8711401104854
8711401021236
8711401021250
8711401021274
8711401021427
8711401104861
8711401039187
8711401039255
8711401020833
8711401019943
8711401020857
8711401020871

N
N
N
N
N
N
N
N
N
N
N
N
Y
Y
Y
Y
Y
Y
N
N
Y
Y
Y
Y

327

Shipline Plus TFXI Power cable 0.6/1 kV


Halogen free shipcable
Part
number
125107
125109
125088
125110
125089
124994
125090
125112
125111
126443
126445
126446
125135
125140
125141
125143
125145
125146
127385
127386
125441
125440
128639
128640
128647
128641
128642
128643
128644
128645
128646

Description

EAN No.
KDN
8711401020888
8711401020901
8711401020666
8711401020918
8711401020673
8711401019721
8711401020680
8711401020932
8711401020925
8711401039231
8711401039279
8711401039293
8711401034243
8711401021366
8711401021397
8711401021311
8711401021434
8711401021465
8711401098979
8711401098993
8711401023933
8711401023919
8711401116659
8711401116666
8711401116741
8711401116673
8711401116680
8711401116895
8711401116703
8711401116727
8711401116734

TFXI 0,6/1kV black 3x10 mm2


TFXI 0,6/1kV black 3x16 mm2
TFXI 0,6/1kV black 3x25 mm2
TFXI 0,6/1kV black 3x35 mm2
TFXI 0,6/1kV black 3x50 mm2
TFXI 0,6/1kV black 3x70 mm2
TFXI 0,6/1kV black 3x95 mm2
TFXI 0,6/1kV black 3x120 mm2
TFXI 0,6/1kV black 3x150 mm2
TFXI 0,6/1kV black 4G1,5 mm2
TFXI 0,6/1kV black 4G2,5 mm2
TFXI 0,6/1kV black 4G6 mm2
TFXI 0,6/1kV black 4x1,5 mm2
TFXI 0,6/1kV black 4x2,5 mm2
TFXI 0,6/1kV black 4x4 mm2
TFXI 0,6/1kV black 4x6 mm2
TFXI 0,6/1kV black 4x10 mm2
TFXI 0,6/1kV black 4x16 mm2
TFXI 0,6/1kV black 5G1,5 mm2
TFXI 0,6/1kV black 5G2,5 mm2
TFXI 0,6/1kV black 5x1,5 mm2
TFXI 0,6/1kV black 5x2,5 mm2
TFXI 0,6/1kV black 6x1,5 mm2
TFXI 0,6/1kV black 7x1,5 mm2
TFXI 0,6/1kV black 8G1,5 mm2
TFXI 0,6/1kV black 8x1,5 mm2
TFXI 0,6/1kV black 10x1,5 mm2
TFXI 0,6/1kV black 12x1,5 mm2
TFXI 0,6/1kV black 16x1,5 mm2
TFXI 0,6/1kV black 19x1,5 mm2
TFXI 0,6/1kV black 24x1,5 mm2

Stock
Item
Y
Y
Y
Y
Y
Y
Y
N
N
N
N
N
Y
Y
Y
Y
N
Y
N
N
N
N
N
N
N
N
N
N
N
N
N

Ambient temperature correction factors


Ambient temp. C
Rating factor

25
1.22

30
1.17

35
1.12

40
1.06

45
1.00

50
0.94

55
0.87

60
0.79

65
0.71

70
0.61

75
0.50

Installation recommendations
Minimum bending radius
during installation
8xD

Minimum bending radius


fixed installed
6xD

Maximum tensile load


during installation
50 N * total cross section
conductors

Subject to change without notice

328

Minimum installation
temperature
-20 C

Shipline Plus TIOI(c) Instrumentation cable 250V


Braided halogen free shipcable

TIOI(c) 250V
XLPE/TCWB/SHF1
Max. conductor temp. : 90C
Nominal voltage
: 250V

Application

Standards applied

Armoured cable for fixed installations on ships


where cable protection is required.
For instrumentation and communication systems.
Can be installed and operated both indoors and
outdoors.

Design
Conductor
Insulation
Sheath
Flame retardant
Halogen Free
Low smoke

- IEC 60092-376
- IEC 60228 class 2
- IEC 60092-351
- IEC 60092-359
- IEC 60332-3-22 (cat A)
- IEC 60754-1,2
- IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded circular copper conductors

Conductor
Insulation

Numbered white cores twisted in pairs (two pair type may be built up
as a star quad). The pairs are twisted with different lay length to
reduce mutual capacitance. One or more polyester tapes may be
applied

Lay up

Screen

Crosslinked polyethylene, XLPE

(c)

Overall screen (polyester tape, tinned copper drain wire, metal coated
polyester tape). A polyester tape is applied over the screen

Inner covering

Flame retardant halogen free thermoplastic compound, SHF1

Armour/screen

Tinned copper wire braid

Outer sheath

Flame retardant halogen free thermoplastic compound, SHF1

Marking text
Outer sheath
colour

DRAKA {factory code} TIOI 250 V .. pair/triple/quad .. mm2


IEC60332-3-22 ShipLine {year of manufacture}
{length indication (meter)}
Grey

329

Shipline Plus TIOI(c) Instrumentation cable 250V


Braided halogen free shipcable
Identification of elements
The pairs have the following number identification according to IEC 60092-376
Pair no. 1
Pair no. 2
Pair no. 3
Pair no. 4

core no. 1 and 2


core no. 3 and 4
core no. 5 and 6
etc.

The single triple is identified


with no 1, 2 and 3
1
The single quad cable has the
following identification

4 + 3
2

Range and dimensions


Elements
(pair)
(triple)
(quad)

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

1 pair

0.75

2.1

0.5

0.2

0.8

9.1

1 triple

0.75

120

52

2.1

0.5

0.2

0.8

9.4

135

1 quad

0.75

62

2.1

0.5

0.2

0.8

10.0

150

4 pair

69

0.75

2.1

0.5

0.3

0.9

14.2

290

147

(mm)

7 pair

0.75

2.1

0.5

0.3

0.9

16.6

395

210

10 pair

0.75

2.1

0.5

0.3

1.0

19.6

510

264

14 pair

0.75

2.1

0.5

0.3

1.1

21.5

640

333

19 pair

0.75

2.1

0.5

0.3

1.1

23.7

785

419

24 pair

0.75

2.1

0.5

0.3

1.2

27.4

970

508

Electrical values
Type

Capacitance
approx.
(nF/km)

Inductance
Approx.
(mH/km)

Single pair/triple 0.75 mm2

70

0.60

26.0

Single quad 0.75 mm2


Multi pair/triple 0,75

60
75

0.50
0.60

26.0
26.0

330

Resistance
at 20 oC
(Ohm/km)

Shipline Plus TIOI(c) Instrumentation cable 250V


Braided halogen free shipcable
Ordering information
Part
number
125154
125156
127195
125157
125159
125160
125161
125162
125163

Description
TIOI(c) 250V grey 1x2x0,75 mm2
TIOI(c) 250V grey 1x4x0,75 mm2
TIOI(c) 250V grey 1x3x0,75 mm2
TIOI(c) 250V grey 4x2x0,75 mm2
TIOI(c) 250V grey 7x2x0,75 mm2
TIOI(c) 250V grey 10x2x0,75 mm2
TIOI(c) 250V grey 14x2x0,75 mm2
TIOI(c) 250V grey 19x2x0,75 mm2
TIOI(c) 250V grey 24x2x0,75 mm2

EAN No.
KDN
8711401030665
8711401021618
8711401072146
8711401004284
8711401030672
8711401030726
8711401030733
8711401030740
8711401030757

Stock
Item
Y
Y
N
Y
Y
Y
N
N
N

Installation recommendations
Minimum bending radius
during installation
8xD

Minimum bending radius


fixed installed
6xD

Maximum tensile load


during installation
50 N * total cross section
conductors

Subject to change without notice

331

Minimum installation
temperature
-20 C

TFOI 12kV(2).doc
21.06.2006 14:02
Page 1 of 2

Shipline TFOI 6/10(12)kV MV Power cable


Flame retardant halogen-free medium
voltage (MV) power cable. Braided

TFOI 6/10(12) kV
XLPE/EPR/TCWB/PO

Operating temperature
Operating Voltage

: 90C
: 6/10(12) kV

Standards applied

Application
Armoured cable for fixed installation in ships where cable
protection is required. Medium Voltage power distribution. Can be
installed and operated both indoors and outdoors.

IEC 60092-354
IEC 60228 class 2
IEC 60092-351
IEC 60092-359
IEC 60332-1
IEC 60332-3-22
IEC 600754-1,2
IEC 61034-1,2

- Design
- Conductor
- Insulation
- Sheath
- Flame Retardant
- Flame Retardant
- Halogen Free
- Low Smoke

Construction
Code
Letter
Conductor
Conductor screen
semiconductive
Insulation

Annealed stranded circular copper, IEC 60228 class 2


Extruded semiconductive layer
T

Insulation screen
semicoductive
Lay up / Shielding
Inner covering
Tape over bedding
Armour/screen
Tape over
armour/screen
Outer sheath
Marking text
Outer sheath colour

F
O

Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)


Extruded semiconductive layer. A copper tape is applied as a metallic
screen above the insulation screen. The thickness of the copper tape is 0,1
mm.
Cores are laid up together. Cores are identified by White, Black or Red
threads under and over the metallic screen on each conductor.
Flame retardant and halogen-free thermoplastic compound
Additional tape may be applied
Tinned copper wire braid
Additional tape may be applied
Flame retardant halogen-free thermoplastic compound, SHF1
E.g. "meter" "year" DRAKA NORSK KABEL TFOI 6/10(12)KV 3 x 95/50
mm2 IEC 60332-3-22 ShipLine
Red

www.drakaMOG.com
332

TFOI 12kV(2).doc
21.06.2006 14:02
Page 2 of 2

Shipline TFOI 6/10(12)kV MV Power cable


Range and dimensions
Cross Cross
Number
Conductor
section section
of
Diameter,
core,
screen,
elements
mm
mm
mm
1
95
10
11.2

Thickness
Insulation Thickness Diameter Diameter
Outer
Thickness, Bedding, bedding, Braid
Sheath,
mm
mm
mm
Wire, mm
mm
3.4
1
22.5 1 0.3
1.7

150

10

14.2

3.4

26 1

0.3

1.8

95

50

11.2

3.4

1.8

48.5 2

0.5

2.6

120

60

12.6

3.4

1.8

52.5
2.5

0.6

2.7

Diameter
outer
sheath,
mm
27 1
30.5
1.5
55.5
2.5

Weight
of Cable
Approx.
(Kg/Km)
1640

Copper
content
Approx.
(kg/km)
1094

2220

1542

6060

3390

60 3

7270

4291

Ordering information
Part number
838504
838506
838525
838526

Description
TFOI 6/10(12)KV 1X 95/10mm2
TFOI 6/10(12)KV 1X 150/10mm2
TFOI 6/10(12)kV 3X 95/50mm
TFOI 6/10(12)kV 3X 120/60mm

EAN No. DNK


7021528385045
7021528385069
7021528385250
7021528385267

EL No.
-

KDN Part number


-

EAN no. KDN


-

Electrical values power cables


Number Cross Cross Conductor
Max.
of
section section
type 2
conductor
elements core, screen,
resistance
mm
mm
at 20C,
Ohm/km
1
1
3
3

95
150
95
120

10
10
50
60

SCC
SCC
SCC
SCC

0.193
0.124
0.193
0.153

Max.
conductor
resistance
at 90C,
Ohm/km
0.246
0.158
0.246
0.195

Reactance Reactance Capacitans


at 50Hz,
at 60Hz, per phase,
Ohm/km
Ohm/km
nF/km

0.119
0.113
0.091
0.088

0.143
0.136
0.109
0.106

300
360
300
330

Current
rating
IEC
60092352,
Ampere
293
389
205
237

Short
circuit
rating 1
second,
Ampere
16800
21000
4900
9800

Ambient temperature correction factors


Ambient Temp C
Rating factor

35
1.10

40
1.05

45
1.00

50
0.94

55
0.88

60
0.82

65
0.74

70
0.67

75
0.58

80
0.47

Installation recommendations
Minimum Bending Radius during
Installation
15 x D

Minimum Bending Radius


Fixed Installed
9xD

Maximum Tensile Load During


Installation
50 N /mm

www.drakaMOG.com
333

Minimum Installation
Temperature
-10C

Shipline Plus TIOI Power cable 0.6/1 kV


Halogen free shipcable

TIOI 0.6/1kV
XLPE/SHF1/TCWB/SHF1
Max. conductor temp. : 90C
Nominal voltage
: 0.6/1 kV

Application

Standards applied

Armoured cable for fixed installations on ships


where cable protection is required.
For power, control and lighting systems.
Can be installed and operated both indoors and
outdoors.

Design
Conductor
Insulation
Sheath
Fire retardant
Halogen Free
Low smoke

- IEC 60092-353
- IEC 60228 class 2 and 5
- IEC 60092-351
- IEC 60092-359
- IEC 60332-3-22 (cat. A)
- IEC 60754-1,2
- IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded circular copper conductors, stranded acc IEC
60228 class 2 or flexible acc IEC 60228 class 5

Conductor
Insulation

Crosslinked polyethylene, XLPE


Cores laid up in one or more layers; in case of cables with more
than 5 cores one or more tapes may be applied over the laid up
cores

Lay up
Inner sheath

Flame retardant halogen free thermoplastic compound SHF1

Armour/screen

Tinned copper wire braid

Outer sheath

Flame retardant halogen free thermoplastic compound, SHF1

Marking text
Outer sheath
colour

DRAKA {factory code} TIOI 0,6/1 kV ..x../.. mm2 IEC60332-3-22


ShipLine Plus {year of manufacture} {length indication (meter)}
Black

334

Shipline Plus TIOI Power cable 0.6/1 kV


Halogen free shipcable
Core identification
Single core
Two cores
Three cores
Four cores
Five cores
Multi core

Black
Blue - Brown
Brown - Black - Grey
Blue - Brown - Black - Grey
Blue - Brown - Black - Grey - Black
White with black numbers

with yellow/green (optional)


Two cores + earth (3G)
Three cores + earth (4G)
Four cores + earth (5G)

Yellow/green - Blue - Brown


Yellow/green - Brown - Black - Grey
Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

Class 5
1

120

10

17.4

1.2

0.3

1.1

23.8

1505

1197

35

16

9.95

0.9

0.3

1.2

29.0

1815

1120

126

Class 2
1

10

2.5

5.4

0.7

0.2

0.8

9.9

205

16

2.5

6.4

0.7

0.2

0.8

11.0

275

183

25

8.1

0.9

0.2

0.9

13.1

405

278

35

9.4

0.9

0.3

0.9

14.7

540

400

50

10.8

1.0

0.3

0.9

16.3

685

515

70

12.8

1.1

0.3

1.0

18.7

930

714

95

10

14.7

1.1

0.3

1.0

20.7

1205

958

120

10

16.5

1.2

0.3

1.1

22.8

1490

1198

150

16

18.4

1.4

0.3

1.1

24.9

1800

1457

185

16

20.7

1.6

0.3

1.2

27.4

2210

1806

240

16

23.4

1.7

0.3

1.2

30.4

2815

2333

300

25

26.0

1.8

0.4

1.3

33.9

3530

2952

400

25

29.3

2.0

0.4

1.4

37.9

4465

3745

1.5

3.0

0.7

0.2

0.8

11.3

200

72

2.5

3.5

0.7

0.2

0.9

12.4

255

96

4.0

0.7

0.3

0.9

13.9

345

158

4.5

0.7

0.3

0.9

15.2

425

202

10

10

5.4

0.7

0.3

1.0

16.9

560

287

16

16

6.4

0.7

0.3

1.0

19.7

805

450

25

16

8.1

0.9

0.3

1.1

23.0

1120

611
777

35

16

9.4

0.9

0.3

1.2

25.9

1405

3G

1.5

3.0

0.7

0.2

0.8

12.0

235

93

3G

2.5

3.5

0.7

0.2

0.9

13.0

290

125

1.5

3.0

0.7

0.2

0.8

12.0

235

93

2.5

3.5

0.7

0.2

0.9

13.0

290

125

4.0

0.7

0.3

0.9

14.5

390

198

335

Shipline Plus TIOI Power cable 0.6/1 kV


Halogen free shipcable
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Insulated
conductor
diameter
(mm)

Insulation
thickness

Braid wires
diameter
(mm)

Outer
sheath
thickness
(mm)

Outer
sheath
diameter
(mm)

4.5

0.7

0.3

0.9

15.9

10

10

5.4

485

254

0.7

0.3

1.0

17.9

665

376

(mm)

Weight
approx.
(kg/km)

Copper
content
approx.
(kg/km)

16

16

6.4

0.7

0.3

1.0

20.7

950

593

25

16

8.1

0.9

0.3

1.1

24.5

1355

830

35

16

9.4

0.9

0.3

1.2

27.6

1740

1104

50

25

10.8

1.0

0.4

1.3

32.6

2425

1530

70

35

12.8

1.1

0.5

1.4

37.6

3355

2177

95

50

14.7

1.1

0.6

1.5

43.2

4570

3071

120

60

16.5

1.2

0.6

1.6

47.5

5680

3871

150

70

18.4

1.4

0.6

1.7

52.1

6780

4613

185

95

20.7

1.6

0.4

1.8

58.9

8680

5959

4G

1.5

3.0

0.7

0.2

0.9

12.8

265

108

4G

2.5

3.5

0.7

0.3

0.9

14.3

360

177

1.5

3.0

0.7

0.2

0.9

12.8

265

108

2.5

3.5

0.7

0.3

0.9

14.3

360

177

4.0

0.7

0.3

0.9

15.8

465

243

4.5

0.7

0.3

1.0

17.2

580

324

10

10

5.4

0.7

0.3

1.0

19.3

795

475

16

16

6.4

0.7

0.3

1.1

22.8

1155

737

25

16

8.1

0.9

0.3

1.2

26.7

1670

1174

35

16

9.4

0.9

0.3

1.2

30.0

2110

1410

50

25

10.8

1.0

0.4

1.4

35.9

3005

1978

70

35

12.8

1.1

0.4

1.5

41.3

4110

2777

95

50

14.7

1.1

0.6

1.6

47.6

5645

3934

5G

1.5

3.0

0.7

0.2

0.9

13.8

300

127

5G

2.5

3.5

0.7

0.3

0.9

15.5

420

208

1.5

3.0

0.7

0.2

0.9

13.8

300

127

2.5

3.5

0.7

0.3

0.9

15.5

420

208

1.5

3.0

0.7

0.3

0.9

14.6

335

174

2.5

3.5

0.7

0.3

0.9

16.1

423

236

1.5

3.0

0.7

0.3

0.9

14.6

345

188

2.5

3.5

0.7

0.3

0.9

16.1

445

257

1.5

3.0

0.7

0.3

0.9

15.9

400

211

10

1.5

10

3.0

0.7

0.3

1.0

17.9

470

254

12

1.5

10

3.0

0.7

0.3

1.0

18.6

525

284

16

1.5

10

3.0

0.7

0.3

1.0

20.3

640

357

19

1.5

10

3.0

0.7

0.3

1.1

21.6

725

400

24

1.5

10

3.0

0.7

0.3

1.1

24.8

920

494

336

Shipline Plus TIOI Power cable 0.6/1 kV


Halogen free shipcable
Electrical values
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Conductor
type

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

Reactance
at 50Hz

Reactance
at 60Hz

(Ohm/km)

(Ohm/km)

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)

Class 5
1

120

10

SCC

0.161

0.2053

0.089

0.107

339

17160

35

16

SCC

0.554

0.7064

0.076

0.092

110

5005

1430

Class 2
1

10

2.5

SCC

1.83

2.33

0.123

0.147

72

16

2.5

SCC

1.15

1.47

0.114

0.137

96

2285

25

SCC

0.727

0.927

0.110

0.132

127

3575

35

SCC

0.524

0.669

0.106

0.128

157

5005

50

SCC

0.387

0.494

0.101

0.121

196

7150

70

SCC

0.268

0.343

0.097

0.117

242

10010

95

10

SCC

0.193

0.248

0.093

0.112

293

13585

120

10

SCC

0.153

0.198

0.091

0.109

339

17160

150

16

SCC

0.124

0.162

0.090

0.109

389

21450

185

16

SCC

0.0991

0.131

0.090

0.107

444

26455

240

16

SCC

0.0754

0.102

0.087

0.104

522

34320

300

25

SCC

0.0601

0.0766

0.087

0.104

601

42900

400

25

SCC

0.047

0.0685

0.086

0.103

670

57200

1.5

SCC

12.1

15.4

0.104

0.125

20

210

2.5

SCC

7.41

9.45

0.098

0.118

26

355

SCC

4.61

5.88

0.092

0.110

34

570

SCC

3.08

3.93

0.088

0.106

44

855

10

10

SCC

1.83

2.33

0.084

0.100

61

1430

16

16

SCC

1.15

1.47

0.080

0.096

82

2285

25

16

SCC

0.727

0.927

0.080

0.097

108

3575
5005

35

16

SCC

0.524

0.669

0.078

0.093

133

3G

1.5

SCC

12.1

15.4

0.104

0.125

20

210

3G

2.5

SCC

7.41

9.45

0.098

0.118

26

355

1.5

SCC

12.1

15.4

0.104

0.125

16

210

2.5

SCC

7.41

9.45

0.098

0.118

21

355

SCC

4.61

5.88

0.092

0.110

28

570

SCC

3.08

3.93

0.088

0.106

36

855

10

10

SCC

1.83

2.33

0.084

0.100

50

1430

16

16

SCC

1.15

1.47

0.080

0.096

67

2285

25

16

SCC

0.727

0.927

0.080

0.097

89

3575

35

16

SCC

0.524

0.669

0.078

0.093

110

5005

50

25

SCC

0.387

0.494

0.074

0.089

137

7150

70

35

SCC

0.268

0.343

0.073

0.088

169

10010

95

50

SCC

0.193

0.248

0.072

0.086

205

13585

120

60

SCC

0.153

0.198

0.070

0.084

237

17160

150

70

SCC

0.124

0.162

0.071

0.085

272

21450

185

95

SCC

0.0991

0.131

0.071

0.086

311

26455

4G

1.5

SCC

12.1

15.4

0.112

0.134

16

210

4G

2.5

SCC

7.41

9.45

0.105

0.126

21

355

1.5

SCC

12.1

15.4

0.112

0.134

14

855

2.5

SCC

7.41

9.45

0.105

0.126

18

210

SCC

4.61

5.88

0.099

0.119

25

355

SCC

3.08

3.93

0.095

0.114

32.5

570

10

10

SCC

1.83

2.33

0.091

0.109

45

855

337

Shipline Plus TIOI Power cable 0.6/1 kV


Halogen free shipcable
Conductors

Conductor
cross
section
(mm2)

Screen
cross
section
(mm2)

Conductor
type

Resistance Resistance
at 20 oC
at 90 oC
DC
50 Hz
(Ohm/km) (Ohm/km)

Reactance
at 50Hz

Reactance
at 60Hz

(Ohm/km)

(Ohm/km)

16

16

SCC

1.15

1.47

0.087

0.105

60

1430

25

16

SCC

0.727

0.927

0.088

0.105

80

3575

35

16

SCC

0.524

0.669

0.085

0.102

98.5

5005

50

25

SCC

0.387

0.494

0.082

0.098

123

7150

70

35

SCC

0.268

0.343

0.080

0.097

152

10010

95

50

SCC

0.193

0.248

0.079

0.095

184.5

13585

5G

1.5

SCC

12.1

15.4

0.114

0.137

14

2285

5G

2.5

SCC

7.41

9.45

0.108

0.130

18

210

1.5

SCC

12.1

15.4

0.114

0.137

13

355

2.5

SCC

7.41

9.45

0.108

0.130

16.5

210

1.5

SCC

12.1

15.4

0.104

0.125

12.5

355

2.5

SCC

7.41

9.45

0.098

0.118

15.5

355

1.5

SCC

12.1

15.4

0.104

0.125

12

210

2.5

SCC

7.41

9.45

0.098

0.118

15

355

1.5

SCC

12.1

15.4

0.104

0.125

11.5

210

10

1.5

10

SCC

12.1

15.4

0.104

0.125

10.5

210

12

1.5

10

SCC

12.1

15.4

0.104

0.125

10

210

16

1.5

10

SCC

12.1

15.4

0.104

0.125

210

19

1.5

10

SCC

12.1

15.4

0.104

0.125

8.5

210

24

1.5

10

SCC

12.1

15.4

0.104

0.125

7.5

210

SCC = Stranded Circular Conductor

Ordering information
Part
number
128637
128223
125043
125044
125047
125048
125050
125058
125059
125051
125053
125055
125056
127296
128714
125061
125078
125080
125081
125034
125035
127321
127328
127379
127380
125020
125016
125021
125022
125019
125024
125023

Description
TIOI cl5 0,6/1kV black 1x120/10 mm2
TIOI cl5 0,6/1kV black 3x35/16 mm2

EAN No.
KDN
8711401106536
8711401105301

Stock
Item
N
N

TIOI 0,6/1kV black 1x10/2,5 mm2


TIOI 0,6/1kV black 1x16/2,5 mm2
TIOI 0,6/1kV black 1x25/4 mm2
TIOI 0,6/1kV black 1x35/6 mm2
TIOI 0,6/1kV black 1x50/6 mm2
TIOI 0,6/1kV black 1x70/6 mm2
TIOI 0,6/1kV black 1x95/10 mm2
TIOI 0,6/1kV black 1x120/10 mm2
TIOI 0,6/1kV black 1x150/16 mm2
TIOI 0,6/1kV black 1x185/16 mm2
TIOI 0,6/1kV black 1x240/16 mm2
TIOI 0,6/1kV black 1x300/25 mm2
TIOI 0,6/1kV black 1x400/25 mm2
TIOI 0,6/1kV black 2x1,5/4 mm2
TIOI 0,6/1kV black 2x2,5/4 mm2
TIOI 0,6/1kV black 2x4/6 mm2
TIOI 0,6/1kV black 2x6/6 mm2
TIOI 0,6/1kV black 2x10/10 mm2
TIOI 0,6/1kV black 2x16/16 mm2
TIOI 0,6/1kV black 2x25/16 mm2
TIOI 0,6/1kV black 2x35/16 mm2
TIOI 0,6/1kV black 3G1,5/4 mm2
TIOI 0,6/1kV black 3G2,5/4 mm2
TIOI 0,6/1kV black 3x1,5/4 mm2
TIOI 0,6/1kV black 3x2,5/4 mm2
TIOI 0,6/1kV black 3x4/6 mm2
TIOI 0,6/1kV black 3x6/6 mm2
TIOI 0,6/1kV black 3x10 mm2
TIOI 0,6/1kV black 3x16 mm2
TIOI 0,6/1kV black 3x25 mm2

8711401020130
8711401020154
8711401020161
8711401020178
8711401020185
8711401020253
8711401020260
8711401020192
8711401020208
8711401020215
8711401020222
8711401083142
8711401119421
8711401020321
8711401119346
8711401119353
8711401020499
8711401020055
8711401020062
8711401093479
8711401093493
8711401095121
8711401095145
8711401020390
8711401119339
8711401020413
8711401119322
8711401019981
8711401119308
8711401019998

N
Y
N
Y
Y
N
N
N
N
N
N
N
N
Y
Y
N
N
N
N
N
N
N
N
Y
Y
Y
Y
Y
Y
Y

338

Current
Short circuit
rating
rating
IEC60092-352
1sec
(A)
(A)

Shipline Plus TIOI Power cable 0.6/1 kV


Halogen free shipcable
Part
number
125069
125067
124995
125032
125026
125030
128707
127381
127382
125082
125092
125094
125095
125036
125040
125041
128022
128024
128023
128025
127383
127384
125407
125408
125096
125100
125099
125117
125118
125122
125123
125126
125127
125128

Description

EAN No.
KDN
8711401119292
8711401119285
8711401019745
8711401020048
8711401119278
8711401020024
8711401119261
8711401095169
8711401095183
8711401020512
8711401119360
8711401020734
8711401020758
8711401020086
8711401020093
8711401020116
8711401102638
8711401102768
8711401102720
8711401102782
8711401097729
8711401098955
8711401023537
8711401023551
8711401020772
8711401020819
8711401020796
8711401020956
8711401020970
8711401021038
8711401021090
8711401021144
8711401021168
8711401021175

TIOI 0,6/1kV black 3x35 mm2


TIOI 0,6/1kV black 3x50 mm2
TIOI 0,6/1kV black 3x70 mm2
TIOI 0,6/1kV black 3x95 mm2
TIOI 0,6/1kV black 3x120 mm2
TIOI 0,6/1kV black 3x150 mm2
TIOI 0,6/1kV black 3x185 mm2
TIOI 0,6/1kV black 4G1,5 mm2
TIOI 0,6/1kV black 4G2,5 mm2
TIOI 0,6/1kV black 4x1,5 mm2
TIOI 0,6/1kV black 4x2,5 mm2
TIOI 0,6/1kV black 4x4 mm2
TIOI 0,6/1kV black 4x6 mm2
TIOI 0,6/1kV black 4x10 mm2
TIOI 0,6/1kV black 4x16 mm2
TIOI 0,6/1kV black 4x25 mm2
TIOI 0,6/1kV black 4x35 mm2
TIOI 0,6/1kV black 4x50 mm2
TIOI 0,6/1kV black 4x70 mm2
TIOI 0,6/1kV black 4x95 mm2
TIOI 0,6/1kV black 5G1,5 mm2
TIOI 0,6/1kV black 5G2,5 mm2
TIOI 0,6/1kV black 5x1,5 mm2
TIOI 0,6/1kV black 5x2,5 mm2
TIOI 0,6/1kV black 6x1,5 mm2
TIOI 0,6/1kV black 6x2,5 mm2
TIOI 0,6/1kV black 7x1,5 mm2
TIOI 0,6/1kV black 7x2,5 mm2
TIOI 0,6/1kV black 8x1,5 mm2
TIOI 0,6/1kV black 10x1,5 mm2
TIOI 0,6/1kV black 12x1,5 mm2
TIOI 0,6/1kV black 16x1,5 mm2
TIOI 0,6/1kV black 19x1,5 mm2
TIOI 0,6/1kV black 24x1,5 mm2

Stock
Item
Y
Y
N
Y
N
N
N
N
N
Y
Y
N
Y
Y
Y
Y
N
N
N
N
N
N
Y
N
Y
N
Y
N
Y
Y
Y
Y
Y
N

Ambient temperature correction factors


Ambient temp. C
Rating factor

25
1.22

30
1.17

35
1.12

40
1.06

45
1.00

50
0.94

55
0.87

60
0.79

65
0.71

70
0.61

75
0.50

Installation recommendations
Minimum bending radius
during installation
8xD

Minimum bending radius


fixed installed
6xD

Maximum tensile load


during installation
50 N * total cross section
conductors

Subject to change without notice

339

Minimum installation
temperature
-20 C

Marine, Oil & Gas International


BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable
Fire resistant, Flame retardant halogen-free
power cable. Enhanced oil-resistance.

BFCU 0.6/1kV
Operating temperature : 90C
Operating Voltage

: 0.6/1kV

Application

Standards applied

Armoured cable for fixed installation for power,


control or lighting in both EX and safe areas,
emergency and critical systems where there is a
requirement for fire resistant cables.

BS7917/BS6883/UKOOA -

Design

BS6360 class 2

Conductor

BS7655 section 1.2

Insulation

BS7655 section 2.6

Sheath

Enhanced MUD resistant version also available for use


in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606.

IEC 60332-1 &3-22

Flame Retardant

IEC60331-21

Fire Resistant

IEC60754-1,2

Halogen Free

IEC 61034-1,2

Low Smoke

Construction
Code
Letter
Tinned stranded circular copper, BS 6360, class 2

Conductor
Insulation

Cores laid up in concentric layers

Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over armour/
screen
Outer sheath
Marking text
Outer sheath colour

Mica glass tape / EP-rubber, GP4 to BS 7655: section 1.2

Flame retardant and halogen-free thermoplastic EP-rubber based compound


PET tape + rubberized Polyamide tape

Galvanized steel wire braid


PET tape + rubberised Polyamide tape

Flame retardant, halogen-free, enhanced oil-resisting thermoset compound


(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "BFCU" "UKOOA code" "600/1000V" "number
of cores" "conductor size" "BS7917" "IEC60331-21 IEC60332-3-22" (marking
may differ on cable actually supplied)
Black

Core identification
All cores are offwhite with black numbers No 1,2,3.

340

Marine, Oil & Gas International


BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable
Range and dimensions
Cross
Conductor Insulation
Number of
section
Diameter, Thickness,
cores
core, mm
mm
mm

Thickness
Inner
Sheath,
mm

Approx
Thickness
Approx
Diameter Diameter
Outer
Overall
Inner
Braid Wire,
Sheath, Diameter,
Sheath,
mm
mm
mm
mm
10
0.3
1.2
14

Weight of
Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

350

46

2.5

2.0

0.8

1.1

1.5

1.6

0.8

1.1

10

0.3

1.2

14

340

42

2.5

2.0

0.8

1.1

10.5

0.3

1.3

15

410

69

1.5

1.6

0.8

1.1

11

0.3

1.3

15

400

56

2.5

2.0

0.8

1.1

11.5

0.3

1.3

16

450

92

2.5

2.0

0.8

1.2

14

0.3

1.4

18.5

620

161

12

2.5

2.0

0.8

1.4

19

0.3

1.6

24

960

275

27

2.5

2.0

0.8

1.7

27.5

0.45

1.9

33.5

1900

618

19

2.5

2.0

0.8

1.5

22.5

0.3

1.7

27.5

1360

435

70

10.85

1.4

2.1

38

0.45

2.4

45

4650

2484

2.55

1.0

1.2

13

0.3

1.3

17

540

110

1.5

1.6

0.8

1.1

9.5

0.3

1.2

13

295

28

12

1.5

1.6

0.8

1.3

17.5

0.3

1.5

22

770

167

3.15

1.0

1.2

14.5

0.3

1.4

18.5

650

164

2.55

1.0

1.2

12.5

0.3

1.3

16.5

470

74

10

4.05

1.0

1.3

16.5

0.3

1.5

21

840

271

10

4.05

1.0

1.3

15.5

0.3

1.4

20

710

181

25

6.45

1.2

1.6

23.5

0.3

1.8

28.5

1710

688

3.15

1.0

1.2

13.5

0.3

1.4

18

570

109

16

5.15

1.0

1.4

18

0.3

1.5

22.5

780

289

3.15

1.0

1.3

16

0.3

1.5

20.5

790

218

35

7.65

1.2

1.8

29

0.45

35

2700

1236

35

7.65

1.2

1.6

24.5

0.3

1.8

29.5

1740

618

35

7.65

1.2

1.7

26

0.45

1.9

32

2210

927

16

5.15

1.0

1.4

19

0.3

1.6

24

1160

434

50

9.0

1.4

1.8

30.5

0.45

36.5

2890

1293

70

10.85

1.4

34.5

0.45

2.2

41

3810

1863

2.55

1.0

1.2

14.5

0.3

1.4

18.5

630

147

95

12.60

1.6

2.2

39.5

0.45

2.4

46.5

4950

2513

1.5

1.6

0.8

1.2

13

0.3

1.3

17

520

98

341

Marine, Oil & Gas International


BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable
Ordering information
Part number

Description

Sheath Colour

Design standard

UKOOA Code

840073

BFCU 0.6/1kV 2X 2.5mm

BLACK

BS 7917 : 1999

YD203

840074

BFCU 0.6/1kV 3X 1.5mm

BLACK

BS 7917 : 1999

YD302

840075

BFCU 0.6/1kV 3X 2.5mm

BLACK

BS 7917 : 1999

YD303

840076

BFCU 0.6/1kV 4X 1.5mm

BLACK

BS 7917 : 1999

YD402

840077

BFCU 0.6/1kV 4X 2.5mm

BLACK

BS 7917 : 1999

YD403

840078

BFCU 0.6/1kV 7X 2.5mm

BLACK

BS 7917 : 1999

YD703

840079

BFCU 0.6/1kV 12X 2.5mm

BLACK

BS 7917 : 1999

YDA03

840108

BFCU 0.6/1kV 27X 2.5mm

BLACK

BS 6883 : 1991

YDC03

840136

BFCU 0.6/1kV 19X 2.5mm

BLACK

BS 7917 : 1999

YDB03

840151

BFCU 0,6/1kV 4X 70 MM2

BLACK

BS 7917 : 1999

YD470

840153

BFCU 0.6/1kV 3X 4mm

BLACK

BS 7917 : 1999

YD304

840162

BFCU 0.6/1kV 2X 1.5mm

BLACK

BS 7917 : 1999

YD202

840165

BFCU 0,6/1kV 12X 1,5mm2

BLACK

BS 7917 : 1999

YDA02

840167

BFCU 0.6/1kV 3X 6mm

BLACK

BS 7917 : 1999

YD306

840230

BFCU 0.6/1kV 2X 4mm

BLACK

BS 7917 : 1999

YD204

840233

BFCU 0.6/1kV 3X 10mm

BLACK

BS 7917 : 1999

YD310

840243

BFCU 0,6/1kV 2X 10MM2

BLACK

BS 7917 : 1999

YD210

840248

BFCU 0.6/1kV 3X 25mm

BLACK

BS 7917 : 1999

YD325

840249

BFCU 0.6/1kV 2X 6mm

BLACK

BS 7917 : 1999

YD206

840250

BFCU 0,6/1kV 2X 16 MM2

BLACK

BS 7917 : 1999

YD216

840257

BFCU 0.6/1kV 4X 6mm

BLACK

BS 7917 : 1999

YD406

840259

BFCU 0.6/1kV 4X 35mm

BLACK

BS 7917 : 1999

YD435

840270

BFCU 0.6/1kV 2X 35mm

BLACK

BS 7917 : 1999

YD235

840273

BFCU 0.6/1kV 3X 35mm

BLACK

BS 7917 : 1999

YD335

840297

BFCU 0.6/1kV 3X 16mm

BLACK

BS 7917 : 1999

YD316

840298

BFCU 0.6/1kV 3X 50mm

BLACK

BS 7917 : 1999

YD350

840299

BFCU 0.6/1kV 3X 70mm

BLACK

BS 7917 : 1999

YD370

840308

BFCU 0.6/1kV 4X 4mm

BLACK

BS 7917 : 1999

YD404

840309

BFCU 0.6/1kV 3X 95mm

BLACK

BS 7917 : 1999

YD370

840310

BFCU 0.6/1kV 7X 1.5mm

BLACK

BS 7917 : 1999

YD702

342

Marine, Oil & Gas International


BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable
Electrical values
Number of
cores

Cross section Max. conductor Max. conductor Reactance at


Reactance at Current rating
core, mm
resistance at
resistance at 50Hz, Ohm/km 60Hz, Ohm/km IEC 60092-352
20C, Ohm/km 90C, Ohm/km
Table B.4,
Ampere

Short circuit
rating 1
second,
Ampere

2.5

7.56

9.64

0.101

0.121

26

350

1.5

12.2

15.6

0.108

0.130

16

210

2.5

7.56

9.64

0.101

0.121

21

350

1.5

12.2

15.6

0.108

0.130

16

210

2.5

7.56

9.64

0.101

0.121

21

350

2.5

7.56

9.64

0.101

0.121

15.5

350

12

2.5

7.56

9.64

0.101

0.121

13

350

27

2.5

7.56

9.64

0.101

0.121

10

350

19

2.5

7.56

9.64

0.101

0.121

11

350

70

0.27

0.344

0.075

0.090

169

9800

4.7

5.99

0.100

0.120

28

560

1.5

12.2

15.6

0.108

0.130

20

210

12

1.5

12.2

15.6

0.108

0.130

10

210

3.11

3.97

0.094

0.112

36

840

4.7

5.99

0.100

0.120

34

560

10

1.84

2.35

0.088

0.105

50

1400

10

1.84

2.35

0.088

0.105

61

1400

25

0.734

0.936

0.081

0.097

89

3500

3.11

3.97

0.094

0.112

44

840

16

1.16

1.48

0.082

0.099

80

2240

3.11

3.97

0.094

0.112

36

840

35

0.529

0.675

0.078

0.094

110

4900

35

0.529

0.675

0.078

0.094

133

4900

35

0.529

0.675

0.078

0.094

110

4900

16

1.16

1.48

0.082

0.099

67

2240

50

0.391

0.499

0.078

0.093

137

7000

70

0.27

0.344

0.075

0.090

169

9800

4.7

5.99

0.100

0.120

28

560

95

0.195

0.249

0.075

0.090

205

13300

1.5

12.2

15.6

0.108

0.130

12

210

Ambient temperature correction factors


Ambient
Temp C
Rating
factor

35

40

45

50

55

60

65

70

75

80

1.11

1.05

1.00

0.94

0.88

0.82

0.75

0.67

0.50

0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During
Installation
Installed
Installation
OD < 25 mm - 4 x D, OD > 25
8xD
50 N /mm
mm - 6 x D
343

Minimum Installation
Temperature
-20C

Marine, Oil & Gas International


BFCU(C) 250V, Fire Resistant, Collective screened instrumentation
Fire resistant, Flame retardant halogen-free
instrumentation cable. Enhanced oil-resistance.

BFCU(C) 250V
Operating temperature : 90C
Operating Voltage

: 250V

Application

Standards applied

Fixed installation for instrumentation, communication,


control and alarm systems in both EX and safe areas,
emergency and critical systems where there is a
requirement for fire resistant cables..

BS7917/BS6883/UKOOA -

BS7655 section 2.6

Sheath

Enhanced MUD resistant version also available for use


in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606.

IEC 60332-1 & 3-22

Flame Retardant

IEC60331-21

Fire Resistant

IEC60754-1,2

Halogen Free

IEC 61034-1,2

Low Smoke

Design

BS6360 class 2 or 5

Conductor

BS7655 section 1.2

Insulation

Construction
Code
Letter
B

Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)
Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)
Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2

Colour coded cores twisted together to form a pair, triple or quad, wrapped
with polyester tape. Pairs, triples or quads are laid up, collectively screened
with aluminium backed polyester tape with tinned copper drain wire. Pairs,
triples, or quads are identified by numbers printed directly on the insulated
conductors.
Flame retardant and halogen-free thermoplastic EP-rubber based compound

Conductor
Insulation
Pair/Triple/Quad
twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over armour/
screen
Outer sheath
Marking text
Outer sheath colour

PET tape + rubberized Polyamide tape


C

Galvanized steel wire braid


PET tape + rubberised Polyamide tape

Flame retardant, halogen-free, enhanced oil-resisting thermoset compound


(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "BFCU(C)" "UKOOA code" "150/250V"
"number of pair, triples or quads" "conductor size" "BS7917" IEC60331-21
"IEC60332-3-22" (marking may differ on cable actually supplied)
Grey or Blue

Core identification
Pair BlackWhite, numbered 1-1, 2-2, 3-3
Triple BlackWhiteRed, numbered 1-1-1, 2-2-2, 3-3-3
Quad BlackWhiteRedBlue, numbered 1-1-1-1, 2-2-2-2 ..
Each core is identified by contrasting numerals & words repeated
344
along the whole length of the cable.

Marine, Oil & Gas International


BFCU(C) 250V, Fire Resistant, Collective screened instrumentation
Range and dimensions

Number
of
elements

Approx
Thickness
Thickness Approx Weight of
No of
Cross Conductor Insulation
Diameter Diameter
Inner
Outer
Overall
Cable
cores in
section Diameter, Thickness
Inner
Braid
Sheath,
Sheath, Diameter Approx.
element core, mm
mm
mm
Sheath, Wire, mm
mm
mm
mm
(Kg/Km)
mm

Copper
content
Approx.
(kg/km)

0.75

1.15

0.8

1.2

13

0.3

1.4

17.5

460

45

0.75

1.15

0.8

1.4

17.5

0.3

1.5

22

740

98

12

0.75

1.15

0.8

1.6

22.5

0.3

1.7

27.5

1120

164

19

0.75

1.15

0.8

1.7

26

0.45

1.9

32

1600

258

27

0.75

1.15

0.8

1.9

31

0.45

2.2

37.5

2190

360

0.75

1.15

0.8

1.2

13

0.3

1.4

17.5

460

45

0.75

1.15

0.8

1.4

17.5

0.3

1.5

22

740

98

12

0.75

1.15

0.8

1.6

22.5

0.3

1.7

27.5

1120

164

19

0.75

1.15

0.8

1.7

26

0.45

1.9

32

1600

258

27

0.75

1.15

0.8

1.9

31

0.45

2.2

37.5

2190

360

1.3

0.8

1.2

13.5

0.3

1.4

18

490

58

1.5

1.6

0.8

1.2

13.5

0.3

1.4

18

470

57

20

0.75

1.15

0.8

1.8

27

0.45

33

1720

271

1.5

1.6

0.8

1.3

14.5

0.3

1.4

19

570

82

1.5

1.6

0.8

1.4

19.5

0.3

1.6

24

920

183

12

1.5

1.6

0.8

1.7

26

0.45

1.9

31.5

1560

310

20

0.75

1.15

0.8

1.8

27

0.45

33

1720

271

20

1.5

1.6

0.8

1.9

31

0.45

2.2

37.5

2260

511

27

1.5

1.6

0.8

2.1

35.5

0.45

2.4

42

2820

688

0.75

1.15

0.8

1.4

19.5

0.3

1.6

24.5

930

144

12

0.75

1.15

0.8

1.7

26

0.3

1.9

31.5

1450

245

2.5

0.8

1.3

16

0.3

1.5

20.5

680

147

12

2.5

0.8

1.8

28.5

0.45

34.5

1960

565

0.75

1.15

0.8

1.2

12

0.3

1.3

16.5

390

31

0.75

1.15

0.8

1.3

15

0.3

1.4

19

550

65

1.5

1.6

0.8

1.5

22

0.3

1.7

27

1180

271

12

1.5

1.6

0.8

1.8

29.5

0.45

35.5

2020

462

1.5

1.6

0.8

1.4

19.5

0.3

1.6

24

920

183

20

1.5

1.6

0.8

1.9

31

0.45

2.2

37.5

2260

511

1.5

1.6

0.8

1.2

13.5 0.8

0.3

1.4

18 0.8

470

57

1.5

1.6

0.8

1.3

14.5 0.8

0.3

1.4

19 0.8

570

82

1.5

1.6

0.8

1.4

18 0.8

0.3

1.6

22.5 1

780

133

1.5

1.6

0.8

1.4

18 0.8

0.3

1.6

22.5 1

780

133

1.5

1.6

0.8

1.4

19.5 0.8

0.3

1.6

24 1

920

183

0.75

1.15

0.8

1.2

12 0.8

0.3

1.3

16.5 0.8

390

31

1.3

0.8

1.2

13.5 0.8

0.3

1.4

18 0.8

490

58

0.75

1.15

0.8

1.3

15.5 0.8

0.3

1.5

20 1

620

71

0.75

1.15

0.8

1.3

15.5 0.8

0.3

1.5

20 1

620

71

0.45

1.9

31.5 1.5

1560

310

12

1.5

1.6

0.8

1.7

345
26 1

Marine, Oil & Gas International


BFCU(C) 250V, Fire Resistant, Collective screened instrumentation
Electrical values

Unshielded pair 0,75 mm

80

0,75

26,7

14

Insulation
resistance
(Minimum MOhm
x km)
940

Unshielded triple 0,75 mm

80

0,75

26,7

14

940

Unshielded pair 1,0 mm

85

0,73

20,0

18

840

Capacitance,
Inductance,
approx. (nF/km) approx, (mH/km)

Type

Resistance at 20
C, max. (Ohm/
km)

L/R ratio,
(microH/Ohm)

Unshielded triple 1,0 mm

85

0,73

20,0

18

840

Unshielded pair 1,5 mm


Unshielded triple 1,5 mm

90
90

0,68
0,68

13,7
13,7

24,8
24,8

730
730

Unshielded pair 2,5 mm


Unshielded triple 2,5 mm

90
90

0,70
0,70

7,56
7,56

46,3
46,3

620
620

Ordering information
Part number

Description

Sheath Colour

Design standard

UKOOA Code

840011

BFCU(C) 250V 3PAIR 0.75mm

GREY

BS 7917 : 1999

GNH00

840012

BFCU(C) 250V 7PAIR 0.75mm

GREY

BS 7917 : 1999

GNJ00

840013

BFCU(C) 250V 12PAIR 0.75mm

GREY

BS 7917 : 1999

GNK00

840014

BFCU(C) 250V 19PAIR 0.75mm

GREY

BS 6883 : 1991

840015

BFCU(C) 250V 27PAIR 0.75mm

GREY

BS 7917 : 1999

GNM00

840031

BFCU(C) 250V 3PAIR 0.75mm

BLUE

BS 7917 : 1999

GLH00

840032

BFCU(C) 250V 7PAIR 0.75mm

BLUE

BS 7917 : 1999

GLJ00

840033

BFCU(C) 250V 12PAIR 0.75mm

BLUE

BS 7917 : 1999

GLK00

840034

BFCU(C) 250V 19PAIR 0.75mm

BLUE

BS 6883 : 1991

840035

BFCU(C) 250V 27PAIR 0.75mm

BLUE

BS 7917 : 1999

GLM00

840090

BFCU(C) 250V 3PAIR 1mm

BLUE

BS 7917 : 1999

GLH01

840111

BFCU(C) 250V 2PAIR 1.5mm

BLUE

BS 6883 : 1991

840124

BFCU(C) 250V 20PAIR 0.75mm

GREY

BS 7917 : 1999

GNL00

840132

BFCU(C) 250V 3PAIR 1.5mm

GREY

BS 6883 : 1991

GNH02

840133

BFCU(C) 250V 7PAIR 1.5mm

GREY

BS 6883 : 1991

GNJ02

840134

BFCU(C) 250V 12PAIR 1.5mm

GREY

BS 6883 : 1991

GNK02

840144

BFCU(C) 250V 20PAIR 0.75mm

BLUE

BS 7917 : 1999

GLL00

840171

BFCU(C) 250V 20PAIR 1.5mm

GREY

BS 6883 : 1991

GNL02

840172

BFCU(C) 250V 27PAIR 1.5mm

GREY

BS 6883 : 1991

GNM02

840173

BFCU(C) 250V 7TRIP 0.75mm

GREY

BS 7917 : 1999

GNT00

840174

BFCU(C) 250V 12TRIP 0.75mm

GREY

BS 7917 : 1999

GNU00

346

Marine, Oil & Gas International


BFCU(C) 250V, Fire Resistant, Collective screened instrumentation
Part number

Description

Sheath Colour

Design standard

UKOOA Code

840203

BFCU(C) 250V 3PAIR 2.5mm

GREY

BS 6883 : 1991

GNH03

840205

BFCU(C) 250V 12PAIR 2.5mm

GREY

BS 6883 : 1991

GNK03

840220

BFCU(C) 250V 2PAIR 0.75mm

GREY

BS 6883 : 1991

840255

BFCU(C) 250V 3TRIP 0.75mm

GREY

BS 7917 : 1999

GNS00

840260

BFCU(C) 250V 7TRIP 1.5mm

GREY

BS 6883 : 1991

GNT02

840261

BFCU(C) 250V 12TRIP 1.5mm

GREY

BS 6883 : 1991

GNU02

840265

BFCU(C) 250V 7PAIR 1.5mm

BLUE

BS 6883 : 1991

GLJ02

840266

BFCU(C) 250V 20PAIR 1.5mm

BLUE

BS 6883 : 1991

GLL02

840285

BFCU(C) 250V 2PAIR 1.5mm

GREY

BS 6883 : 1991

840286

BFCU(C) 250V 3PAIR 1.5mm

BLUE

BS 6883 : 1991

GLH02

840287

BFCU(C) 250V 5PAIR 1.5mm

GREY

BS 6883 : 1991

840288

BFCU(C) 250V 5PAIR 1.5mm

BLUE

BS 6883 : 1991

840289

BFCU(C) 250V 7PAIR 1.5mm

BLUE

BS 6883 : 1991

GLJ02

840317

BFCU(C) 250V 2PAIR 0.75mm

BLUE

BS 6883 : 1991

840318

BFCU(C) 250V 3PAIR 1mm

GREY

BS 7917 : 1999

GNH01

840319

BFCU(C) 250V 5PAIR 0.75mm

GREY

BS 6883 : 1991

840320

BFCU(C) 250V 5PAIR 0.75mm

BLUE

BS 6883 : 1991

840321

BFCU(C) 250V 12PAIR 1.5mm

BLUE

BS 6883 : 1991

GLK02

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed
Installation
Installed
10 x D

Maximum Tensile Load During


Installation

Minimum Installation
Temperature

50 N /mm

-20C

8xD

347

Marine, Oil & Gas International


BFCU(I) 250V, Fire Resistant, Individual screened instrumentation
Fire resistant, Flame retardant halogen-free
instrumentation cable. Enhanced oil-resistance.

BFCU(I) 250V
Operating temperature : 90C
Operating Voltage

: 250V

Application

Standards applied

Fixed installation for instrumentation, communication,


control and alarm systems in both EX and safe areas,
emergency and critical systems where there is a
requirement for fire resistant cables..

BS7917/6883/UKOOA

BS7655 section 2.6

Sheath

Enhanced MUD resistant version also available for use


in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606.

IEC 60332-1 & 3-22

Flame Retardant

IEC60331-21

Fire Resistant

IEC60754-1,2

Halogen Free

IEC 61034-1,2

Low Smoke

Design

BS6360 class 2 or 5

Conductor

BS7655 section 1.2

Insulation

Construction
Code
Letter
B

Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)
Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)
Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2

Colour coded cores twisted together to form a pair, triple or quad, which is
individually screened with aluminium backed polyester tape with a tinned
copper drain wire. Each pair, triple or quad is wrapped with polyester tape to
prevent electrical contact with adjacent pairs, triples or quads.
Individually shielded pairs, triples or quads are laid up in concentric layers and
wrapped with a PETP tape.
Pairs, triples, or quads are identified by numbers printed directly on the
insulated conductors.
Flame retardant and halogen-free thermoplastic EP-rubber based compound

Conductor
Insulation

Pair/Triple/Quad
twisting / lay up

Inner covering
Tape over inner
covering
Armour/screen
Tape over armour/
screen
Outer sheath
Marking text
Outer sheath colour

PET tape + rubberized Polyamide tape


C

Galvanized steel wire braid


PET tape + rubberised Polyamide tape

Flame retardant, halogen-free, enhanced oil-resisting thermoset compound


(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "BFCU(I)" "UKOOA code" "150/250V"
"number of pair, triples or quads" "conductor size" "BS7917" IEC60331-21
"IEC60332-3-22" (marking may differ on cable actually supplied)
Grey or Blue

Core identification
Pair BlackWhite, numbered 1-1, 2-2, 3-3
Triple BlackWhiteRed, numbered 1-1-1, 2-2-2, 3-3-3
Quad BlackWhiteRedBlue, numbered 1-1-1-1, 2-2-2-2 ..
Each core is identified by contrasting numerals & words repeated
348
along the whole length of the cable.

Marine, Oil & Gas International


BFCU(I) 250V, Fire Resistant, Individual screened instrumentation
Range and dimensions
Number
of
elements

Approx
Thickness
Thickness Approx Weight of
Diameter Diameter
No of
Cross Conductor Insulation
Inner
Outer
Overall
Cable
Inner
cores in
section Diameter, Thickness
Braid
Sheath,
Sheath, Diameter Approx.
Sheath, Wire, mm
element core, mm
mm
mm
mm
mm
mm
(Kg/Km)
mm

Copper
content
Approx.
(kg/km)

0.75

1.15

0.8

0.3

1.2

12

260

18

0.75

1.15

0.8

1.2

10

0.3

1.3

14

330

31

0.75

1.15

0.8

8.5

0.3

1.2

12.5

280

25

0.75

1.15

0.8

1.3

14.5

0.3

1.5

19

590

73

0.75

1.15

0.8

1.5

20

0.3

1.7

24.5

990

171

12

0.75

1.15

0.8

1.7

26.5

0.45

32.5

1640

293

0.75

1.15

0.8

0.3

1.2

12

245

18

0.75

1.15

0.8

1.2

10

0.3

1.3

14

330

31

0.75

1.15

0.8

8.5

0.3

1.2

12.5

280

25

0.75

1.15

0.8

1.3

14.5

0.3

1.5

19

590

73

0.75

1.15

0.8

1.5

20

0.3

1.7

24.5

990

171

12

0.75

1.15

0.8

1.7

26.5

0.45

32.5

1640

293

1.5

1.6

0.8

1.1

9.5

0.3

1.2

13

300

32

1.5

1.6

0.8

1.2

11

0.3

1.4

15.5

410

57

1.5

1.6

0.8

1.1

9.5

0.3

1.2

13

300

32

1.5

1.6

0.8

1.2

11

0.3

1.4

15.5

410

57

1.5

1.6

0.8

1.1

10

0.3

1.2

14

330

45

1.3

0.8

8.5

0.3

1.2

12.5

270

24

1.3

0.8

8.5

0.3

1.2

12.5

270

24

0.75

1.15

0.8

1.4

18

0.3

1.6

22.5

800

124

1.3

0.8

1.1

0.3

1.2

13

310

32

1.5

1.6

0.8

1.1

10

0.3

1.2

14

330

45

1.5

1.6

0.8

1.5

20.5

0.3

1.7

25

1030

222

1.5

1.6

0.8

1.5

20.5

0.3

1.7

25

1030

222

1.5

1.6

0.8

1.3

14

0.3

1.4

18.5

500

64

1.3

0.8

1.2

10

0.3

1.4

14.5

360

41

1.3

0.8

1.2

10

0.3

1.4

14.5

360

41

1.3

0.8

1.1

0.3

1.2

13

310

32

0.75

1.15

0.8

1.4

18

0.3

1.6

22.5

800

124

20

0.75

1.15

0.8

1.9

30

0.45

2.1

36.5

2040

354

2.5

0.8

1.3

12

0.3

1.5

16.5

500

100

0.75

1.15

0.8

1.2

13.5

0.3

1.4

17.5

480

53

1.3

0.8

1.3

14

0.3

1.4

18.5

520

71

0.75

1.15

0.8

1.2

0.3

1.4

17.5

480

53

34913.5

Marine, Oil & Gas International


BFCU(I) 250V, Fire Resistant, Individual screened instrumentation
Number
of
elements
12

Approx
Thickness
Thickness Approx Weight of
No of
Cross Conductor Insulation
Diameter Diameter
Inner
Outer
Overall
Cable
cores in
section Diameter, Thickness
Braid
Inner
Sheath,
Sheath, Diameter Approx.
element core, mm
mm
mm
Sheath, Wire, mm
mm
mm
mm
(Kg/Km)
mm
2
0.75
1.15
0.8
1.6
24
0.3
1.8
29
1240

Copper
content
Approx.
(kg/km)
213

20

0.75

1.15

0.8

1.9

30

0.45

2.1

36.5

2040

354

0.75

1.15

0.8

1.3

16

0.3

1.5

20.5

660

89

1.5

1.6

0.8

1.3

15

0.3

1.5

19.5

600

96

0.75

1.15

0.8

1.3

16

0.3

1.5

20.5

660

89

20

1.5

1.6

0.8

34

0.45

2.3

41

2640

636

1.5

1.6

0.8

1.2

11

0.3

1.4

15.5

410

57

1.5

1.6

0.8

1.4

18.5

0.3

1.6

23

840

159

1.5

1.6

0.8

1.4

18.5

0.3

1.6

23

840

159

12

0.75

1.15

0.8

1.6

24

0.3

1.8

29

1240

213

0.75

1.15

0.8

1.2

12.5

0.3

1.4

17

430

36

1.5

1.6

0.8

1.3

14

0.3

1.4

18.5

500

64

0.75

1.15

0.8

1.2

12.5

0.3

1.4

17

430

36

0.75

1.15

0.8

1.3

14

0.3

1.4

18

490

49

1.3

0.8

1.3

14.5

0.3

1.5

19

530

65

1.5

1.6

0.8

1.3

15.5

0.3

1.5

20

600

89

1.3

0.8

1.3

15.5

0.3

1.5

20

630

97

1.5

1.6

0.8

1.4

16.5

0.3

1.5

21

730

134

1.3

0.8

1.3

14

0.3

1.4

18.5

520

71

1.5

1.6

0.8

1.3

15

0.3

1.5

19.5

600

96

12

1.5

1.6

0.8

1.8

27.5

0.45

33.5

1750

382

12

1.5

1.6

0.8

1.8

27.5

0.45

33.5

1750

382

20

1.5

1.6

0.8

34

0.45

2.3

41

2640

636

Electrical values
Type
Shielded pair 0,75 mm
Shielded triple 0,75 mm
Shielded quad 0,75 mm
Shielded pair 1 mm
Shielded triple 1 mm
Shielded quad 1 mm
Shielded pair 1,5 mm
Shielded triple 1,5 mm
Shielded quad 1,5 mm
Shielded pair 2,5 mm

Capacitance,
Inductance, Resistance at 20 L/R ratio, (microH/
approx. (nF/km) approx (mH/km) C, max. (Ohm/km)
Ohm)
90
90
60
100
100
70
110
110
80
120

0,75
0,75
0,91
0,73
0,73
0,95
0,68
0,68
0,99
0,70

350

26,7
26,7
26,7
20,0
20,0
20,0
13,7
13,7
13,7
7,56

14
14
14
18
18
18
24,8
24,8
24,8
46,3

Insulation
resistance
(Minimum
MOhmx km)
940
940
940
840
840
840
730
730
730
620

Marine, Oil & Gas International


BFCU(I) 250V, Fire Resistant, Individual screened instrumentation
Ordering information
Part number

Description

Sheath Colour

Design standard

UKOOA Code

840009

BFCU(I) 250V 1PAIR 0.75mm

GREY

BS 7917 : 1999

GPF00

840010

BFCU(I) 250V 1QUAD 0.75mm

GREY

BS 7917 : 1999

GPX00

840017

BFCU(I) 250V 1TRIP 0.75mm

GREY

BS 7917 : 1999

GPR00

840018

BFCU(I) 250V 3TRIP 0.75mm

GREY

BS 7917 : 1999

GPS00

840019

BFCU(I) 250V 7TRIP 0.75mm

GREY

BS 7917 : 1999

GPT00

840020

BFCU(I) 250V 12TRIP 0.75mm

GREY

BS 7917 : 1999

GPU00

840029

BFCU(I) 250V 1PAIR 0.75mm

BLUE

BS 7917 : 1999

GMF00

840030

BFCU(I) 250V 1QUAD 0.75mm

BLUE

BS 7917 : 1999

GMX00

840037

BFCU(I) 250V 1TRIP 0.75mm

BLUE

BS 7917 : 1999

GMR00

840038

BFCU(I) 250V 3TRIP 0.75mm

BLUE

BS 7917 : 1999

GMS00

840039

BFCU(I) 250V 7TRIP 0.75mm

BLUE

BS 7917 : 1999

GMT00

840040

BFCU(I) 250V 12TRIP 0.75mm

BLUE

BS 7917 : 1999

GMU00

840041

BFCU(I) 250V 1PAIR 1.5mm

GREY

BS 6883 : 1991

GPF02

840042

BFCU(I) 250V 1QUAD 1.5mm

GREY

BS 6883 : 1991

GPX02

840045

BFCU(I) 250V 1PAIR 1.5mm

BLUE

BS 6883 : 1991

GMF02

840046

BFCU(I) 250V 1QUAD 1.5mm

BLUE

BS 6883 : 1991

GMX02

840087

BFCU(I) 250V 1TRIP 1.5mm

BLUE

BS 6883 : 1991

GMR02

840089

BFCU(I) 250V 1PAIR 1mm

BLUE

BS 7917 : 1999

GMF01

840123

BFCU(I) 250V 1PAIR 1mm

GREY

BS 7917 : 1999

GPF01

840125

BFCU(I) 250V 7PAIR 0.75mm

GREY

BS 7917 : 1999

GPJ00

840127

BFCU(I) 250V 1TRIP 1mm

GREY

BS 7917 : 1999

GPR01

840131

BFCU(I) 250V 1TRIP 1.5mm

GREY

BS 6883 : 1991

GPR02

840138

BFCU(I) 250V 7PAIR 1.5mm

GREY

BS 6883 : 1991

GPJ02

840139

BFCU(I) 250V 7PAIR 1.5mm

BLUE

BS 6883 : 1991

GMJ02

840140

BFCU(I) 250V 2PAIR 1.5mm

BLUE

BS 6883 : 1991

840141

BFCU(I) 250V 1QUAD 1mm

GREY

BS 7917 : 1999

GPX01

840142

BFCU(I) 250V 1QUAD 1mm

BLUE

BS 7917 : 1999

GMX01

840157

BFCU(I) 250V 1TRIP 1mm

BLUE

BS 7917 : 1999

GMR01

840175

BFCU(I) 250V 7PAIR 0.75mm

BLUE

BS 7917 : 1999

GMJ00

840200

BFCU(I) 250V 20PAIR 0.75mm

GREY

BS 7917 : 1999

GPL00

840202

BFCU(I) 250V 1QUAD 2.5mm

GREY

BS 6883 : 1991

GPX03

840217

BFCU(I) 250V 3PAIR 0.75mm

BLUE

BS 7917 : 1999

GMH00

840218

BFCU(I) 250V 3PAIR 1mm

GREY

BS 7917 : 1999

GPH01

840240

BFCU(I) 250V 3PAIR 0.75mm

GREY

BS 7917 : 1999

GPH00

840253

BFCU(I) 250V 12PAIR 0.75mm

GREY

BS 7917 : 1999

GPK00

840254

BFCU(I) 250V 20PAIR 0.75mm

BLUE

BS 7917 : 1999

GML00

840267

BFCU(I) 250V 5PAIR 0.75mm

BLUE

BS 6883 : 1991

840268

BFCU(I) 250V 3PAIR 1.5mm

GREY

BS 6883 : 1991

GPH02

840271

BFCU(I) 250V 5PAIR 0.75mm

GREY

BS 6883 : 1991

840280

BFCU(I) 250V 20PAIR 1.5mm

GREY

BS 6883 : 1991

GPL02

840281

BFCU(I) 250V 1QUAD 1.5mm

GREY

BS 6883 : 1991

GPX02

840290

BFCU(I) 250V 5PAIR 1.5mm

GREY

BS 6883 : 1991

BFCU(I) 250V 5PAIR 1.5mm

351
BLUE

BS 6883 : 1991

840291

Marine, Oil & Gas International


BFCU(I) 250V, Fire Resistant, Individual screened instrumentation
Part number

Description

Sheath Colour

Design standard

UKOOA Code

840292

BFCU(I) 250V 12PAIR 0.75mm

BLUE

BS 7917 : 1999

GMK00

840314

BFCU(I) 250V 2PAIR 0.75mm

GREY

BS 6883 : 1991

840315

BFCU(I) 250V 2PAIR 1.5mm

GREY

BS 6883 : 1991

840316

BFCU(I) 250V 2PAIR 0.75mm

BLUE

BS 6883 : 1991

840322

BFCU(I) 250V 2TRIP 0.75mm

GREY

BS 6883 : 1991

840323

BFCU(I) 250V 2TRIP 1mm

GREY

BS 6883 : 1991

840324

BFCU(I) 250V 2TRIP 1.5mm

GREY

BS 6883 : 1991

840325

BFCU(I) 250V 3TRIP 1mm

GREY

BS 7917 : 1999

GPS01

840326

BFCU(I) 250V 3TRIP 1.5mm

GREY

BS 6883 : 1991

GPS02

840327

BFCU(I) 250V 3PAIR 1mm

BLUE

BS 7917 : 1999

GMH01

840328

BFCU(I) 250V 3PAIR 1.5mm

BLUE

BS 6883 : 1991

GMH02

840329

BFCU(I) 250V 12PAIR 1.5mm

GREY

BS 6883 : 1991

GPK02

840330

BFCU(I) 250V 12PAIR 1.5mm

BLUE

BS 6883 : 1991

GMK02

840331

BFCU(I) 250V 20PAIR 1.5mm

BLUE

BS 6883 : 1991

GML02

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed
Installation
Installed
10 x D

Maximum Tensile Load During


Installation

Minimum Installation
Temperature

50 N /mm

-20C

8xD

352

Marine, Oil & Gas International


RFCU 0.6/1KV Power, Control or Lighting cable
Flame retardant halogen-free power cable.
Enhanced oil-resistance.

RFCU 0.6/1kV
Operating temperature : 90C
Operating Voltage

: 0,6/1kV

Application

Standards applied

Armoured cable for fixed installation for power,


control or lighting in both EX and safe areas where
cable protection is required. General purpose use.

BS6883 / UKOOA

Design

BS6360 class 2

Conductor

BS7655 section 1.2

Insulation

Enhanced MUD resistant version also available for use


in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606.

BS7655 section 2.6

Sheath

IEC 60332-1

Flame Retardant

IEC60332-3-22

Flame retardant

IEC60754-1,2

Halogen Free

IEC 61034-1,2

Low Smoke

Construction
Code
Letter
Tinned stranded circular copper, BS 6360, class 2

Conductor
Insulation

Cores laid up in concentric layers

Lay up / Shielding
Inner covering
Tape over inner
covering
Armour/screen
Tape over armour/
screen
Outer sheath
Marking text
Outer sheath colour

EP-rubber, GP4 to BS 7655: section 1.2

Flame retardant and halogen-free thermoset compound


PET tape + rubberized Polyamide tape

Galvanized steel wire braid


PET tape + rubberised Polyamide tape

Flame retardant, halogen-free, enhanced oil-resisting thermoset compound


(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "RFCU" "UKOOA code" "600/1000V" "number
of cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ
on cable actually supplied)
Black

Core identification
All cores are offwhite with black numbers No 1,2,3.

353

Marine, Oil & Gas International


RFCU 0.6/1KV Power, Control or Lighting cable
Range and dimensions
Cross
Conductor Insulation
Number of
section
Diameter, Thickness,
cores
core, mm
mm
mm
1.6

0.8

Thickness
Inner
Sheath,
mm

1.5

1.1

2.5

2.0

0.8

1.1

2.55

1.0

1.2

1.5

1.6

0.8

1.1

2.5

2.0

0.8

1.1

2.55

1.0

1.2

3.15

1.0

16

5.15

1.0

35

7.65

1.2

Approx
Thickness
Approx
Diameter Diameter
Outer
Overall
Braid Wire,
inner
Sheath,
Diameter,
mm
Sheath,
mm
mm
mm
8.5

Weight of
Cable
Approx.
(Kg/Km)

Copper
content
Approx.
(kg/km)

0.3

1.2

12.5

280

28

9.5

0.3

1.2

13.5

320

46

11.5

0.3

1.3

15.5

440

74

0.3

1.2

13

310

42

10

0.3

1.3

14

360

69

12.5

0.3

1.3

16.5

490

110

1.2

13.5

0.3

1.4

18

610

164

1.4

18.5

0.3

1.6

23

1120

434

1.7

25.5

0.45

1.9

31

2150

927

70

10.85

1.4

34

0.45

2.2

40

3770

1863

1.5

1.6

0.8

1.1

10

0.3

1.3

14

350

56

2.55

1.0

1.2

13.5

0.3

1.4

18

590

147

3.15

1.0

1.3

15

0.3

1.5

19.5

740

218

16

5.15

1.0

1.5

20.5

0.3

1.7

25.5

1390

578

25

6.45

1.2

1.7

25

0.45

1.9

31

2130

917

35

7.65

1.2

1.8

28

0.45

34

2620

1236

2.5

2.0

0.8

1.2

13.5

0.3

1.4

18.5

590

161

12

2.5

2.0

0.8

1.4

18

0.3

1.6

22.5

900

275

19

2.5

2.0

0.8

1.5

21

0.3

1.7

27

1240

435

70

10.85

1.4

2.1

38

0.45

2.4

44

4670

2484

10

4.05

1.0

1.3

16

0.3

1.5

20.5

830

271

25

6.45

1.2

1.6

22.5

0.3

1.8

28

1640

688

10

4.05

1.0

1.4

17.5

0.3

1.6

22.5

1000

361

19

1.5

1.6

0.8

1.4

19

0.3

1.6

24

960

264

50

9.0

1.4

1.9

33

0.45

2.2

39.5

3480

1716

95

12.60

1.6

2.3

43.5

0.45

2.6

50.5

6080

3351

3.15

1.0

1.2

13

0.3

1.4

17

540

109

3.15

1.0

1.3

15

0.3

1.5

19.5

740

218

37

2.5

2.0

0.8

1.8

29

0.45

35

2270

847

16

5.15

1.0

1.4

17.5

0.3

1.5

22

940

289

27

2.5

2.0

0.8

1.7

25.5

0.45

1.9

31.5

1820

618

1.5

1.6

0.8

1.2

12

0.3

1.3

17

470

98

12

1.5

1.6

0.8

1.3

16

0.3

1.5

20.5

710

167

35

7.65

1.2

1.6

23.5

0.3

1.8

28.5

1650

618

50

9.0

1.4

1.8

29.5

0.45

35

2830

1287

2.5

2.0

0.8

1.1

11

0.3

1.3

15

420

92

95

12.60

1.6

2.2

39

0.45

2.4

45

4860

2513

1.5

1.6

0.8

1.1

11

0.3

1.3

15

440

83

354

Marine, Oil & Gas International


RFCU 0.6/1KV Power, Control or Lighting cable
Ordering information
Part number

Description

Sheath Colour

Design standard

UKOOA Code

840049

RFCU 0.6/1kV 2X 1.5mm

BLACK

BS 6883 : 1999

WB202

840050

RFCU 0.6/1kV 2X 2.5mm

BLACK

BS 6883 : 1999

WB203

840051

RFCU 0.6/1kV 2X 4mm

BLACK

BS 6883 : 1999

WB204

840052

RFCU 0.6/1kV 3X 1.5mm

BLACK

BS 6883 : 1999

WB302

840053

RFCU 0.6/1kV 3X 2.5mm

BLACK

BS 6883 : 1999

WB303

840054

RFCU 0.6/1kV 3X 4mm

BLACK

BS 6883 : 1999

WB304

840055

RFCU 0.6/1kV 3X 6mm

BLACK

BS 6883 : 1999

WB306

840056

RFCU 0.6/1kV 3X 16mm

BLACK

BS 6883 : 1999

WB316

840057

RFCU 0.6/1kV 3X 35mm

BLACK

BS 6883 : 1999

WB335

840058

RFCU 0.6/1kV 3X 70mm

BLACK

BS 6883 : 1999

WB370

840059

RFCU 0.6/1kV 4X 1.5mm

BLACK

BS 6883 : 1999

WB402

840061

RFCU 0.6/1kV 4X 4mm

BLACK

BS 6883 : 1999

WB404

840062

RFCU 0.6/1kV 4X 6mm

BLACK

BS 6883 : 1999

WB406

840063

RFCU 0.6/1kV 4X 16mm

BLACK

BS 6883 : 1999

WB416

840064

RFCU 0.6/1kV 4X 25mm

BLACK

BS 6883 : 1999

WB425

840065

RFCU 0.6/1kV 4X 35mm

BLACK

BS 6883 : 1999

WB435

840068

RFCU 0.6/1kV 7X 2.5mm

BLACK

BS 6883 : 1999

WB703

840070

RFCU 0.6/1kV 12X 2.5mm

BLACK

BS 6883 : 1999

WBA03

840071

RFCU 0.6/1kV 19X 2.5mm

BLACK

BS 6883 : 1999

WBB03

840088

RFCU 0.6/1kV 4X 70mm

BLACK

BS 6883 : 1999

WB470

840154

RFCU 0.6/1kV 3X 10mm

BLACK

BS 6883 : 1999

WB310

840158

RFCU 0.6/1kV 3X 25mm

BLACK

BS 6883 : 1999

WB325

840159

RFCU 0.6/1kV 4X 10mm

BLACK

BS 6883 : 1999

WB410

840160

RFCU 0.6/1kV 19X 1.5mm

BLACK

BS 6883 : 1999

WBB02

840166

RFCU 0.6/1kV 4X 50mm

BLACK

BS 6883 : 1999

WB450

840242

RFCU 0.6/1kV 4X 95mm

BLACK

BS 6883 : 1999

WB495

840245

RFCU 0.6/1kV 2X 6mm

BLACK

BS 6883 : 1999

WB206

840246

RFCU 0.6/1kV 4X 6mm

BLACK

BS 6883 : 1999

WB406

840256

RFCU 0.6/1kV 37X 2.5mm

BLACK

BS 6883 : 1991

WBD03

840258

RFCU 0.6/1kV 2X 16mm

BLACK

BS 6883 : 1999

WB216

840262

RFCU 0.6/1kV 27X 2.5mm

BLACK

BS 6883 : 1991

WBC03

840263

RFCU 0.6/1kV 7X 1.5mm

BLACK

BS 6883 : 1999

WB702

840264

RFCU 0.6/1kV 12X 1.5mm

BLACK

BS 6883 : 1999

WBA02

840269

RFCU 0.6/1kV 2X 35mm

BLACK

BS 6883 : 1999

WB235

840283

RFCU 0.6/1kV 3X 50mm

BLACK

BS 6883 : 1999

WB350

840284

RFCU 0.6/1kV 4X 2.5mm

BLACK

BS 6883 : 1999

WB403

840311

RFCU 0.6/1kV 3X 95mm

BLACK

BS 6883 : 1999

WB395

RFCU 0.6/1kV 5X 1.5mm

355
BLACK

BS 6883 : 1999

840338

Marine, Oil & Gas International


RFCU 0.6/1KV Power, Control or Lighting cable
Electrical values
Number of
cores

Cross section Max. conductor Max. conductor Reactance at


Reactance at Current rating
core, mm
resistance at
resistance at 50Hz, Ohm/km 60Hz, Ohm/km IEC 60092-352
20C, Ohm/km 90C, Ohm/km
Table B.4,
Ampere

2
2
2
3
3
3
3
3
3
3
4
4
4
4
4
4
7
12
19
4
3
3
4
19
4
4
2
4
37
2
27
7
12
2
3
4
3
5

1.5
2.5
4
1.5
2.5
4
6
16
35
70
1.5
4
6
16
25
35
2.5
2.5
2.5
70
10
25
10
1.5
50
95
6
6
2.5
16
2.5
1.5
1.5
35
50
2.5
95
1.5

12.2
7.56
4.7
12.2
7.56
4.7
3.11
1.16
0.529
0.27
12.2
4.7
3.11
1.16
0.734
0.529
7.56
7.56
7.56
0.27
1.84
0.734
1.84
12.2
0.391
0.195
3.11
3.11
7.56
1.16
7.56
12.2
12.2
0.529
0.391
7.56
0.195
12.2

15.6
9.64
5.99
15.6
9.64
5.99
3.97
1.48
0.675
0.344
15.6
5.99
3.97
1.48
0.936
0.675
9.64
9.64
9.64
0.344
2.35
0.936
2.35
15.6
0.499
0.249
3.97
3.97
9.64
1.48
9.64
15.6
15.6
0.675
0.499
9.64
0.249
15.6

0.103
0.096
0.096
0.103
0.096
0.096
0.090
0.080
0.076
0.074
0.103
0.096
0.090
0.080
0.079
0.076
0.096
0.096
0.096
0.074
0.084
0.079
0.084
0.103
0.076
0.073
0.090
0.090
0.096
0.080
0.096
0.103
0.103
0.076
0.076
0.096
0.073
0.103

0.123
0.115
0.115
0.123
0.115
0.115
0.108
0.096
0.092
0.088
0.123
0.115
0.108
0.096
0.095
0.092
0.115
0.115
0.115
0.088
0.101
0.095
0.101
0.123
0.092
0.088
0.108
0.108
0.115
0.096
0.115
0.123
0.123
0.092
0.092
0.115
0.088
0.123

Short circuit
rating 1
second,
Ampere

20
26
34
16
21
28
36
67
110
169
16
28
36
67
89
110
15.5
13
11
169
50
89
50
8.5
137
205
44
36
9
80
10
12
10
133
137
21
205
13.5

210
350
560
210
350
560
840
2240
4900
9800
210
560
840
2240
3500
4900
350
350
350
9800
1400
3500
1400
210
7000
13300
840
840
350
2240
350
210
210
4900
7000
350
13300
210

Ambient temperature correction factors


Ambient
Temp C
Rating
factor

35

40

45

50

55

60

65

70

75

80

1.11

1.05

1.00

0.94

0.88

0.82

0.75

0.67

0.50

0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed
Installation
Installed
OD < 25 mm - 4 x D, OD > 25
8xD
mm - 6 x D

Maximum Tensile Load During


Installation

Minimum Installation
Temperature

50 N /mm

-20C

356

Marine, Oil & Gas International


RFCU(C) 250V, Collective screened instrumentation
Flame retardant halogen-free instrumentation
cable. Enhanced oil-resistance.

RFCU(C) 250V
Operating temperature : 90C
Operating Voltage
Application

Standards applied

Fixed installation for instrumentation, communication,


control and alarm systems in both EX and safe areas.

BS6883 / UKOOA

Enhanced MUD resistant version also available for use


in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606.

: 250V

Design

BS6360 class 2 or 5

Conductor

BS7655 section 1.2

Insulation

BS7655 section 2.6

Sheath

IEC 60332-1

Flame Retardant

IEC60332-3-22

Flame retardant

IEC60754-1,2

Halogen Free

IEC 61034-1,2

Low Smoke

Construction
Code
Letter
R

Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)
Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)
EP-rubber, GP4 to BS 7655: section 1.2

Colour coded cores twisted together to form a pair, triple or quad, wrapped
with polyester tape. Pairs, triples or quads are laid up, collectively screened
with aluminium backed polyester tape with tinned copper drain wire. Pairs,
triples, or quads are identified by numbers printed directly on the insulated
conductors.
Flame retardant and halogen-free thermoset compound

Conductor
Insulation
Pair/Triple/Quad
twisting
Inner covering
Tape over inner
covering
Armour/screen
Tape over armour/
screen
Outer sheath
Marking text
Outer sheath colour

PET tape + rubberized Polyamide tape


C

Galvanized steel wire braid


PET tape + rubberised Polyamide tape

Flame retardant, halogen-free, enhanced oil-resisting thermoset compound


(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "RFCU(C)" "UKOOA code" "150/250V"
"number of pair, triples or quads" "conductor size" "BS6883" "IEC60332-322" (marking may differ on cable actually supplied)
Grey or Blue

Core identification
Pair BlackWhite, numbered 1-1, 2-2, 3-3
Triple BlackWhiteRed, numbered 1-1-1, 2-2-2, 3-3-3
Quad BlackWhiteRedBlue, numbered 1-1-1-1, 2-2-2-2 ..
Each core is identified by contrasting numerals & words repeated
357
along the whole length of the cable.

Marine, Oil & Gas International


RFCU(C) 250V, Collective screened instrumentation
Range and dimensions
Number
of
elements

Thickness Diameter
Thickness Approx Weight of
No of
Cross Conductor Insulation
Diameter
Inner
Inner
Outer
Overall
Cable
cores in
section Diameter, Thickness
Braid
Sheath,
Sheath,
Sheath, Diameter , Approx.
element core, mm
mm
mm
Wire, mm
mm
mm
mm
mm
(Kg/Km)

Copper
content
Approx.
(kg/km)

0.75

1.15

0.8

1.2

12

0.3

1.4

16.5

420

45

0.75

1.15

0.8

1.4

16.5

0.3

1.5

21

660

97

12

0.75

1.15

0.8

1.6

21.5

0.3

1.7

26

1000

164

27

0.75

1.15

0.8

1.9

29

0.45

2.2

35.5

1980

359

0.75

1.15

0.8

1.2

12

0.3

1.4

16.5

420

45

0.75

1.15

0.8

1.4

16.5

0.3

1.5

21

660

97

12

0.75

1.15

0.8

1.6

21.5

0.3

1.7

26

1000

164

19

0.75

1.15

0.8

1.7

24.5

0.45

1.9

30

1460

257

27

0.75

1.15

0.8

1.9

29

0.45

2.2

35.5

1980

359

1.3

0.8

1.2

12

0.3

1.4

16.5

400

41

20

0.75

1.15

0.8

1.8

25.5

0.45

31.5

1570

271

20

0.75

1.15

0.8

1.8

25.5

0.45

31.5

1570

271

1.5

1.6

0.8

1.4

18.5

0.3

1.6

23

850

183

12

1.5

1.6

0.8

1.7

24.5

0.45

1.9

30

1470

309

20

1.5

1.6

0.8

1.9

29

0.45

2.2

35.5

2130

511

27

1.5

1.6

0.8

2.1

33.5

0.45

2.4

40

2650

687

0.75

1.15

0.8

1.4

18

0.3

1.6

22.5

820

144

12

0.75

1.15

0.8

1.7

24

0.3

1.9

29

1290

244

0.75

1.15

0.8

1.3

13.5

0.3

1.4

18

510

65

1.5

1.6

0.8

1.3

14

0.3

1.4

18

520

82

1.5

1.6

0.8

1.3

14

0.3

1.4

18

520

82

1.3

0.8

1.2

12.5

0.3

1.4

17

460

58

0.75

1.15

0.8

1.3

13.5

0.3

1.4

18

510

65

12

1.5

1.6

0.8

1.8

27.5

0.45

33.5

1840

461

1.5

1.6

0.8

1.3

14

0.3

1.4

18

520

82

1.5

1.6

0.8

1.4

17

0.3

1.6

21.5

730

132

0.75

1.15

0.8

1.2

11.5

0.3

1.3

15.5

370

31

1.5

1.6

0.8

1.2

13

0.3

1.4

17

450

57

0.75

1.15

0.8

1.3

15

0.3

1.5

19.5

570

71

358

Marine, Oil & Gas International


RFCU(C) 250V, Collective screened instrumentation
Electrical values
Inductance,
Capacitance,
approx, (mH/
approx. (nF/km)
km)

Type
Unshielded pair 0,75 mm
Unshielded triple 0,75 mm
Unshielded pair 1,0 mm
Unshielded triple 1,0 mm
Unshielded pair 1,5 mm
Unshielded triple 1,5 mm
Unshielded pair 2,5 mm
Unshielded triple 2,5 mm

80
80
85
85
90
90
90
90

Resistance at
20C, max.
(Ohm/km)

L/R ratio,
(microH/Ohm)

26,7
26,7
20,0
20,0
13,7
13,7
7,56
7,56

14
14
18
18
24,8
24,8
46,3
46,3

0,75
0,75
0,73
0,73
0,68
0,68
0,70
0,70

Insulation
resistance
(Minimum
Mohm x km)
940
940
840
840
730
730
620
620

Ordering information
Part number
840003

Description
RFCU(C) 250V 3PAIR 0.75mm

Sheath Colour
GREY

Design standard
BS 6883 : 1999

UKOOA Code
KJH00

840004

RFCU(C) 250V 7PAIR 0.75mm

GREY

BS 6883 : 1999

KJJ00

840005

RFCU(C) 250V 12PAIR 0.75mm

GREY

BS 6883 : 1999

KJK00

840007

RFCU(C) 250V 27PAIR 0.75mm

GREY

BS 6883 : 1999

KJM00

840023

RFCU(C) 250V 3PAIR 0.75mm

BLUE

BS 6883 : 1999

KGH00

840024

RFCU(C) 250V 7PAIR 0.75mm

BLUE

BS 6883 : 1999

KGJ00

840025

RFCU(C) 250V 12PAIR 0.75mm

BLUE

BS 6883 : 1999

KGK00

840026

RFCU(C) 250V 19PAIR 0.75mm

BLUE

BS 6883 : 1991

840027

RFCU(C) 250V 27PAIR 0.75mm

BLUE

BS 6883 : 1999

KGM00

840117

RFCU(C) 250V 2PAIR 1mm

GREY

BS 6883 : 1991

840128

RFCU(C) 250V 20PAIR 0.75mm

GREY

BS 6883 : 1999

KJL00

840156

RFCU(C) 250V 20PAIR 0.75mm

BLUE

BS 6883 : 1999

KGL00

840176

RFCU(C) 250V 7PAIR 1.5mm

GREY

BS 6883 : 1991

KJJ02

840177

RFCU(C) 250V 12PAIR 1.5mm

GREY

BS 6883 : 1991

KJK02

840178

RFCU(C) 250V 20PAIR 1.5mm

GREY

BS 6883 : 1991

KJL02

840179

RFCU(C) 250V 27PAIR 1.5mm

GREY

BS 6883 : 1991

KJM02

840222

RFCU(C) 250V 7TRIP 0.75mm

BLUE

BS 6883 : 1999

KGT00

840223

RFCU(C) 250V 12TRIP 0.75mm

BLUE

BS 6883 : 1999

KGU00

840231

RFCU(C) 250V 3TRIP 0.75mm

GREY

BS 6883 : 1999

KJS00

840236

RFCU(C) 250V 3PAIR 1.5mm

BLUE

BS 6883 : 1991

KGH02

840237

RFCU(C) 250V 3PAIR 1.5mm

GREY

BS 6883 : 1991

KJH02

840241

RFCU(C) 250V 3PAIR 1mm

GREY

BS 6883 : 1999

KJH01

840274

RFCU(C) 250V 3TRIP 0.75mm

GREY

BS 6883 : 1999

KJS00

840277

RFCU(C) 250V 12TRIP 1.5mm

BLUE

BS 6883 : 1991

KGU02

840294

RFCU(C) 250V 3PAIR 1.5mm

GREY

BS 6883 : 1991

KJH02

840295

RFCU(C) 250V 5PAIR 1.5mm

GREY

BS 6883 : 1991

840332

RFCU(C) 250V 2PAIR 0.75mm

GREY

BS 6883 : 1991

840333

RFCU(C) 250V 2PAIR 1.5mm

GREY

BS 6883 : 1991

840334

RFCU(C) 250V 5PAIR 0.75mm

GREY

BS 6883 : 1991

359

Marine, Oil & Gas International


RFCU(C) 250V, Collective screened instrumentation

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed
Installation
Installed
10 x D

Maximum Tensile Load During


Installation

Minimum Installation
Temperature

50 N /mm

-20C

8xD

360

Marine, Oil & Gas International


RFCU(I) 250V, Individual screened instrumentation
Flame retardant halogen-free instrumentation
cable. Enhanced oil-resistance.

RFCU(I) 250V
Operating temperature : 90C
Operating Voltage
Application

Standards applied

Fixed installation for instrumentation, communication,


control and alarm systems in both EX and safe areas.

BS6883 / UKOOA

Enhanced MUD resistant version also available for use


in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606.

: 250V

Design

BS6360 class 2 or 5

Conductor

BS7655 section 1.2

Insulation

BS7655 section 2.6

Sheath

IEC 60332-1

Flame Retardant

IEC60332-3-22

Flame retardant

IEC60754-1,2

Halogen Free

IEC 61034-1,2

Low Smoke

Construction
Code
Letter
R

Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)
Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)
EP-rubber, GP4 to BS 7655: section 1.2

Colour coded cores twisted together to form a pair, triple or quad, which is
individually screened with aluminium backed polyester tape with a tinned
copper drain wire. Each pair, triple or quad is wrapped with polyester tape to
prevent electrical contact with adjacent pairs, triples or quads.
Individually shielded pairs, triples or quads are laid up in concentric layers and
wrapped with a PETP tape.
Pairs, triples, or quads are identified by numbers printed directly on the
insulated conductors.
Flame retardant and halogen-free thermoset compound

Conductor
Insulation

Pair/Triple/Quad
twisting / lay up

Inner covering
Tape over inner
covering
Armour/screen
Tape over armour/
screen
Outer sheath
Marking text
Outer sheath colour

PET tape + rubberized Polyamide tape


C

Galvanized steel wire braid


PET tape + rubberised Polyamide tape

Flame retardant, halogen-free, enhanced oil-resisting thermoset compound


(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "RFCU(I)" "UKOOA code" "150/250V"
"number of pair, triples or quads" "conductor size" "BS6883" "IEC60332-322" (marking may differ on cable actually supplied)
Grey or Blue

Core identification
Pair BlackWhite, numbered 1-1, 2-2, 3-3
Triple BlackWhiteRed, numbered 1-1-1, 2-2-2, 3-3-3
Quad BlackWhiteRedBlue, numbered 1-1-1-1, 2-2-2-2 ..
Each core is identified by contrasting numerals & words repeated
361
along the whole length of the cable.

Marine, Oil & Gas International


RFCU(I) 250V, Individual screened instrumentation
Range and dimensions
Number
of
elements

Approx
Thickness
Thickness Approx Weight of
Diameter Diameter
No of
Cross Conductor Insulation
Inner
Outer
Overall
Cable
Inner
cores in
section Diameter, Thickness
Braid
Sheath,
Sheath, Diameter Approx.
Sheath, Wire, mm
element core, mm
mm
mm
mm
mm
mm
(Kg/Km)
mm

Copper
content
Approx.
(kg/km)

0.75

1.15

0.8

7.5

0.3

1.2

11.5

230

18

0.75

1.15

0.8

1.2

0.3

1.3

13.5

310

31

0.75

1.15

0.8

7.5

0.3

1.2

11.5

230

18

0.75

1.15

0.8

1.2

0.3

1.3

13.5

310

31

1.3

0.8

0.3

1.2

12

240

24

1.3

0.8

0.3

1.2

12

240

24

1.3

0.8

1.2

9.5

0.3

1.4

14

340

41

1.3

0.8

1.3

13

0.3

1.4

17

490

71

1.3

0.8

1.1

8.5

0.3

1.2

12.5

285

32

0.75

1.15

0.8

1.5

18.5

0.3

1.7

23.5

900

170

12

0.75

1.15

0.8

1.7

25

0.45

31

1530

293

0.75

1.15

0.8

1.4

16.5

0.3

1.6

21

720

124

0.75

1.15

0.8

1.4

16.5

0.3

1.6

21

720

124

12

0.75

1.15

0.8

1.6

22

0.3

1.8

27

1110

212

12

0.75

1.15

0.8

1.6

22

0.3

1.8

27

1110

212

0.75

1.15

0.8

1.3

14

0.3

1.5

18.5

530

73

0.75

1.15

0.8

1.2

12

0.3

1.4

16.5

430

53

0.75

1.15

0.8

1.2

12

0.3

1.4

16.5

430

53

20

1.5

1.6

0.8

31.5

0.45

2.3

38

2430

635

19

0.75

1.15

0.8

1.8

26

0.45

32

1660

336

12

0.75

1.15

0.8

1.7

25

0.45

31

1530

293

0.75

1.15

0.8

1.5

18.5

0.3

1.7

23.5

900

170

1.5

1.6

0.8

1.3

14

0.3

1.5

18.5

560

95

0.75

1.15

0.8

1.3

14

0.3

1.5

18.5

530

73

1.5

1.6

0.8

1.3

14

0.3

1.5

18.5

560

95

1.5

1.6

0.8

1.1

8.5

0.3

1.2

12.5

290

32

1.5

1.6

0.8

1.1

0.3

1.2

13

320

45

0.75

1.15

0.8

0.3

1.2

12

245

25

1.3

0.8

1.2

9.5

0.3

1.4

14

340

41

1.5

1.6

0.8

1.2

10

0.3

1.4

14.5

370

57

1.5

1.6

0.8

1.1

0.3

1.2

13

320

45

362

Marine, Oil & Gas International


RFCU(I) 250V, Individual screened instrumentation
Electrical values
Inductance,
Capacitance,
Resistance at 20C, L/R ratio, (microH/
approx (mH/
approx. (nF/km)
max. (Ohm/km)
Ohm)
km)

Type
Shielded pair 0,75 mm
Shielded triple 0,75 mm
Shielded quad 0,75 mm
Shielded pair 1 mm
Shielded triple 1 mm
Shielded quad 1 mm
Shielded pair 1,5 mm
Shielded triple 1,5 mm
Shielded quad 1,5 mm
Shielded pair 2,5 mm

90
90
60
100
100
70
110
110
80
120

0,75
0,75
0,91
0,73
0,73
0,95
0,68
0,68
0,99
0,70

26,7
26,7
26,7
20,0
20,0
20,0
13,7
13,7
13,7
7,56

14
14
14
18
18
18
24,8
24,8
24,8
46,3

Insulation
resistance
(Minimum MOhmx
km)
940
940
940
840
840
840
730
730
730
620

Ordering information
Part number

Description

Sheath Colour

Design standard

UKOOA Code

840001
840002
840021
840022
840094
840095
840096
840100
840121
840211
840212
840214
840215
840216
840221
840224
840226
840227
840235
840238
840239
840272
840275
840276
840278
840293
840296
840335
840336
840337
840339

RFCU(I) 250V 1PAIR 0.75mm


RFCU(I) 250V 1QUAD 0.75mm
RFCU(I) 250V 1PAIR 0.75mm
RFCU(I) 250V 1QUAD 0.75mm
RFCU(I) 250V 1PAIR 1mm
RFCU(I) 250V 1PAIR 1mm
RFCU(I) 250V 1QUAD 1mm
RFCU(I) 250V 3PAIR 1mm
RFCU(I) 250V 1TRIP 1mm
RFCU(I) 250V 7TRIP 0.75mm
RFCU(I) 250V 12TRIP 0.75mm
RFCU(I) 250V 7PAIR 0.75mm
RFCU(I) 250V 7PAIR 0.75mm
RFCU(I) 250V 12PAIR 0.75mm
RFCU(I) 250V 12PAIR 0.75mm
RFCU(I) 250V 3TRIP 0.75mm
RFCU(I) 250V 3PAIR 0.75mm
RFCU(I) 250V 3PAIR 0.75mm
RFCU(I) 250V 20PAIR 1.5mm
RFCU(I) 250V 19PAIR 0.75mm
RFCU(I) 250V 12TRIP 0.75mm
RFCU(I) 250V 7TRIP 0.75mm
RFCU(I) 250V 3PAIR 1.5mm
RFCU(I) 250V 3TRIP 0.75mm
RFCU(I) 250V 3PAIR 1.5mm
RFCU(I) 250V 1PAIR 1.5mm
RFCU(I) 250V 1TRIP 1.5mm
RFCU(I) 250V 1TRIP 0.75mm
RFCU(I) 250V 1QUAD 1mm
RFCU(I) 250V 1QUAD 1.5mm
RFCU(I) 250V 1TRIP 1.5mm

GREY
GREY
BLUE
BLUE
GREY
BLUE
BLUE
BLUE
GREY
BLUE
BLUE
GREY
BLUE
GREY
BLUE
BLUE
GREY
BLUE
GREY
BLUE
GREY
GREY
GREY
GREY
BLUE
GREY
GREY
GREY
GREY
GREY
BLUE

BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1991
BS 6883 : 1991
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1991
BS 6883 : 1999
BS 6883 : 1991
BS 6883 : 1991
BS 6883 : 1991
BS 6883 : 1999
BS 6883 : 1999
BS 6883 : 1991
BS 6883 : 1991

KKF00
KKX00
KHF00
KHX00
KKF01
KHF01
KHX01
KHH01
KKR01
KHT00
KHU00
KKJ00
KHJ00
KKK00
KHK00
KHS00
KKH00
KHH00
KKL02
KKU00
KKT00
KKH02
KKS00
KHH02
KKF02
KKR02
KKR00
KKX01
KKX02
KHR02

363

Marine, Oil & Gas International


RFCU(I) 250V, Individual screened instrumentation

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed
Installation
Installed
10 x D

Maximum Tensile Load During


Installation

Minimum Installation
Temperature

50 N /mm

-20C

8xD

364

Marine, Oil & Gas International


RU 0.6/1KV Unarmoured power cable
Flame retardant halogen-free power cable.
Enhanced oil-resistance.

RU 0.6/1kV
Operating temperature : 90C
Operating Voltage

: 0.6/1kV

Application

Standards applied

Unarmoured cable for fixed installation where cable


protection is not required. Power, control and lighting
in safe areas.

BS6883

Design

BS6360 class 2

Conductor

BS7655 section 1.2

Insulation

Enhanced MUD resistant version also available for use


in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606.

BS7655 section 2.6

Sheath

IEC 60332-1

Flame Retardant

IEC60332-3-22

Flame retardant

IEC60754-1,2

Halogen Free

IEC 61034-1,2

Low Smoke

Construction
Code
Letter
Conductor
Insulation
Inner sheath
Armour/screen
Outer sheath

Tinned stranded circular copper, BS6360, class 2


EP-rubber, GP4 to BS7655:section 1.2
No inner sheath, additional tapes may be applied
No armour
Flame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF)
SW4 to BS7655 section 2.6. (Mud resistant version available on request)

Marking text

"metre mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number of


cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable
actually supplied)

Outer sheath
colour

Black

Core identification
All cores are offwhite with black numbers No 1,2,3.

365

Marine, Oil & Gas International


RU 0.6/1KV Unarmoured power cable
Range and dimensions
Number of
cores

Cross section
core, mm

2
2
3
3
3
3
4
4
3
3

1.5
2.5
1.5
2.5
4
6
1.5
2.5
10
16

Weight of
Copper content
Conductor
Insulation
Thickness Outer Approx Overall
Cable Approx.
Approx.
Diameter, mm Thickness, mm
Sheath, mm
Diameter, mm
(Kg/Km)
(Kg/Km)
1.6
0.8
1.1
8.5
120
28
2.0
0.8
1.1
9.5
150
46
1.6
0.8
1.1
9
140
42
2.0
0.8
1.1
10
180
69
2.55
1.0
1.2
12
275
110
3.15
1.0
1.2
13.5
360
164
1.6
0.8
1.1
10
165
56
2.0
0.8
1.1
11
220
92
4.05
1.0
1.3
15.5
530
271
5.15
1.0
1.4
18
770
434

Ordering information
Part number
840300

Description
RU 0.6/1kV 2X 1.5mm

Sheath Colour
BLACK

Design standard
BS 6883:1999

840301

RU 0.6/1kV 2X 2.5mm

BLACK

BS 6883:1999

840302

RU 0.6/1kV 3X 1.5mm

BLACK

BS 6883:1999

840303

RU 0.6/1kV 3X 2.5mm

BLACK

BS 6883:1999

840304

RU 0.6/1kV 3X 4mm

BLACK

BS 6883:1999

840305

RU 0.6/1kV 3X 6mm

BLACK

BS 6883:1999

840306

RU 0.6/1kV 4X 1.5mm

BLACK

BS 6883:1999

840307

RU 0.6/1kV 4X 2.5mm

BLACK

BS 6883:1999

840312

RU 0.6/1kV 3X 10mm

BLACK

BS 6883:1999

840313

RU 0.6/1kV 3X 16mm

BLACK

BS 6883:1999

Electrical values
Number of
cores

Cross section Max. conductor Max. conductor Reactance at


Reactance at Current rating
core, mm
resistance at
resistance at 50Hz, Ohm/km 60Hz, Ohm/km IEC 60092-352
20C, Ohm/km 90C, Ohm/km
Table B.4,
Ampere
1.5
12.2
15.6
0.103
0.123
20

Short circuit
rating 1
second,
Ampere
210

2.5

7.56

9.64

0.096

0.115

26

350

1.5

12.2

15.6

0.103

0.123

16

210

2.5

7.56

9.64

0.096

0.115

21

350

4.7

5.90

0.096

0.115

28

560

3.11

3.97

0.090

0.108

36

840

1.5

12.2

15.6

0.103

0.123

16

210

2.5

7.56

9.64

0.096

0.115

21

350

10

1.84

2.35

0.084

0.101

50

1400

16

1.16

1.48

0.080

0.096

67

2240

Ambient temperature correction factors


Ambient
Temp C
Rating
factor

35

40

45

50

55

60

65

70

75

80

1.11

1.05

1.00

0.94

0.88

0.82

0.75

0.67

0.50

0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During
Installation
Installed
Installation
OD < 25 mm - 4 x D, OD > 25
8xD
50 N /mm
366
mm - 6 x D

Minimum Installation
Temperature
-20C

Marine, Oil & Gas International


RU 0.6/1KV Earthing cable
Flame retardant halogen-free earthing cable.
Enhanced oil-resistance.

RU 0.6/1kV
Operating temperature : 90C
Operating Voltage

: 0.6/1kV

Application

Standards applied

Unarmoured cable for fixed installation for earthing


purposes in safe areas.

BS6883

Design

BS6360 class 2

Conductor

BS7655 section 1.2

Insulation

Enhanced MUD resistant version also available for use


in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606.

BS7655 section 2.6

Sheath

IEC 60332-1

Flame Retardant

IEC60332-3-22

Flame retardant

IEC60754-1,2

Halogen Free

IEC 61034-1,2

Low Smoke

Construction
Code
Letter
Conductor
Insulation
Inner sheath
Armour/screen
Outer sheath

Tinned stranded circular copper, BS6360, class 2


EP-rubber, GP4 to BS7655:section 1.2
No inner sheath, additional tapes may be applied
No armour
Flame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF)
SW4 to BS7655 section 2.6. (Mud resistant version available on request)

Marking text

"metre mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number of


cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable
actually supplied)

Outer sheath
colour

Green/Yellow

Core identification
Single core - off white

367

Marine, Oil & Gas International


RU 0.6/1KV Earthing cable
Range and dimensions
Thickness
Conductor
Insulation
Outer Sheath,
Diameter, mm Thickness, mm
mm

Approx Overall
Diameter, mm

Approx Weight Copper content


of Cable
Approx.
(Kg/Km)
(Kg/Km)

Number of
cores

Cross section
core, mm

3.15

1.0

7.5

115

55

16

5.15

1.0

1.1

9.5

230

144

25

6.45

1.2

1.2

11.5

340

229

35

7.65

1.2

1.2

12.5

440

308

70

10.85

1.4

1.3

16.5

820

620

Ordering information
Part number

Description

Sheath Colour

Design standard

840080

RU 0.6/1kV 1X 6mm

YELLOW/GREEN

BS 6883:1999

840081

RU 0.6/1kV 1X 16mm

YELLOW/GREEN

BS 6883:1999

840082

RU 0.6/1kV 1X 25mm

YELLOW/GREEN

BS 6883:1999

840083

RU 0.6/1kV 1X 35mm

YELLOW/GREEN

BS 6883:1999

840084

RU 0.6/1kV 1X 70mm

YELLOW/GREEN

BS 6883:1999

Electrical values
Number of cores

Cross section core,


mm

Max. conductor
resistance at 20C,
Ohm/km

Max. conductor
resistance at 90C,
Ohm/km

Current rating IEC


60092-352 Table
B.4, Ampere

Short circuit rating 1


second, Ampere

3.11

3.97

52

840

16

1.16

1.48

96

2240

25

0.734

0.936

127

3500

35

0.529

0.675

157

4900

70

0.27

0.344

242

9800

Ambient temperature correction factors


Ambient
Temp C
Rating
factor

35

40

45

50

55

60

65

70

75

80

1.11

1.05

1.00

0.94

0.88

0.82

0.75

0.67

0.50

0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed
Installation
Installed
OD < 25 mm - 4 x D, OD > 25
8xD
mm - 6 x D

Maximum Tensile Load During


Installation

Minimum Installation
Temperature

50 N /mm

-20C

368

For maintenance and repair needs, or expert guidance for new-build


projects, please contact any of our worldwide locations:

EUROPE:
Unit 3 Peterseat Drive
Peterseat Park
Altens Industrial Estate
Aberdeen AB12 3HT
U.K.
tel: +44 1224 244800
fax: +44 1224 249839

AMERICAS:
1610 Greens Road, Suite
300
Houston, TX 77032
U.S.A.
tel: +1 281 209 1070
fax: +1 281 209 3857

www.DrakaMOG.com

2009 Draka Offshore. All rights reserved.