The following page(s) are extracted from multi-page Kuhnke product catalogs or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have been combined to provide technical information about the specific product(s) you have selected. Hard copy product catalogs, and CDROMs have been published describing Kuhnke Pneumatics, Solenoids, Relays and Electronics; some divided into different books. A list of current publications is available on this web site or from our sales offices. Some may be available for download, but as substantially larger files.
Contact Details
Kuhnke sales and service in North America Ellis/Kuhnke Controls 26 West Highland Avenue Atlantic Highlands New Jersey 07716 USA T: 800-221-0714 T: 732-291-3334 F: 732-291-8154 Email: sales@kuhnkeusa.com
Important Note The information shown in these documents is for guidance only. No liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper application of the parts, assemblies or equipment described.
Magnet Hauptkatalog
104
Main catalogue
Die obenstehenden Hochleistungs-Hubmagnete Typ RM werden als Vorzugstypen lagermig gefhrt, damit Sie einen schnellen und preisgnstigen Zugriff fr Ihre Versuche haben. Die Vorzugstypen sind in kleinen Stckzahlen (Zwischenverkauf vorbehalten) innerhalb einer Woche lieferbar. Sie sind ausgelegt fr 24 V DC und 100 % ED. Bei Verwendung einer verstellbaren Spannungsquelle kann der Magnet ber die Nennspannung hinaus betrieben werden, um die fr die Bettigung erforderliche Kraft zu erreichen. Beachten Sie hierbei bitte, da bei lngerem Betrieb an erhhter Betriebsspannung diese Magnete berhitzt werden, wenn nicht ausreichende Pausen bei einer max. Spieldauer (Einschaltzeit + Ausschaltzeit) von 5 Minuten eingehalten werden. Zu Ihrer Information hier der mathematische Zusammenhang: U= UN
2.162
The heavy duty solenoids listed in the table are preferred types and are always in stock, enabling you to have them delivered quickly and at a competitive price for your tests. The preferred types can be delivered within a week (in small numbers) conditional to no resale. They are designed to operate at 24 V DC and 100 % ED.
If an adjustable voltage source is used, the solenoid can be operated at a higher voltage than that given in the rating, in order to obtain the required power.
However, these solenoids are subject to overheating during long term use with increased voltage, unless sufficiently long intervals and a maximal operating time (switch on time + switch off time) of 5 min are observed.
U= ED 100
UN
2.162
ED 100
U = Betriebsspannung (Anwender) UN = Nennspannung bzw. Standardspannung 24 V DC ED = relative Einschaltdauer (%) Zur Ermittlung der fr Ihren Anwendungsfall erforderlichen Kraft ist der Spulenstrom zu messen. Die genaue Festlegung der Spule erfolgt in unserer Entwicklungsabteilung: Geben Sie uns bitte hierzu den Magnetspulenstrom an, unter Bercksichtigung der geforderten max. Einschaltdauer.
U = applied operating voltage UN = rated voltage or standard voltage 24 V DC ED = relative duty cycle (%) In order to calculate the power required in your case, the coil current has to be measured. The exact determination of the duty cycle is made in our development laboratories. We would therefore ask you to supply us with the value for coil current taking into consideration the max. duty cycle requested.
Magnet Hauptkatalog
105
Main catalogue
Hochleistungs-Hubmagnet RM 13
Stoende und ziehende Ausfhrung
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)
RM RM
Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 B 75 Prfspannung: 600 V (eff) In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
1,5 5 2 5 2
Insulation group according to: VDE 0110 B 75 Test voltage: 600 V (eff) Return spring optional.
13
M6
2,8 Dimensions given with armature in fully home position > Direction of stroke 5 43,3
2)
3 8 9
34 50
+1
6+0,5
% W
100 2,9
50 5,4
25 10,1
% W
2) Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen)
If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)
10 8 5 F [N]
%ED
Kraft-Weg-Diagramm F = f (s)
1
25 0,5 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 50 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position
0,2 0,1
100 0 1 2 3 4 5 S [mm] 6
Magnet Hauptkatalog
106
Main catalogue
Hochleistungs-Hubmagnet RM 20
Stoende und ziehende Ausfhrung
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Steckhlsenanschlu 2,8 DIN 46247 Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)
RM RM
Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 C 300 Prfspannung: 800 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
M3 M3
Insulation group according to: VDE 0110 C 300 Test voltage: 800 V (eff) Service-free DU armature bearing for maximum durability. Return spring optional.
Mae im bestromten Zustand > Hubrichtung Zul. rel. Einschaltdauer (ED)2) Nennaufnahme P 20 Anzugszeit (ED)
2)
SW14
M6
2 8
8 12
12 16 20 15 21 5 59 5
2)
Dimensions given with armature in fully home position > Direction of stroke % W ms Perm. duty cycle (ED)2) Nominal coil power P 20 Actuation time (ED)
25 13,5
Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) %ED
If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)
100 50 F [N] 20
Kraft-Weg-Diagramm F = f (s)
10 5 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand
2 1
2 S [mm]
Magnet Hauptkatalog
107
Main catalogue
Hochleistungs-Hubmagnet RM 26
Stoende und ziehende Ausfhrung
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)
RM RM
Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 B 150 Prfspannung: 800 V (eff) Wartunsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Waagerechte Kennlinie auf Anfrage. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
M3 M3 M10
Insulation group according to: VDE 0110 B 150 Test voltage: 800 V (eff) Service-free DU armature bearing for maximum durability. Linear force vs. stroke output optional. Return spring optional.
Mae im bestromten Zustand > Hubrichtung Zul. rel. Einschaltdauer (ED)2) Nennaufnahme P 20
SW17
2 10
8 13
17 19 26 15 35,3 5 84
2)
Dimensions given with armature in fully home position > Direction of stroke % W Perm. duty cycle (ED)2) Nominal coil power P 20
25 18,9
2) Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen)
If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)
100 50 F [N]
%ED
20
Kraft-Weg-Diagramm F = f (s)
10 5 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand 3 2 1
5 15 25 40
Force measured when operating in horizontal 100 position, at 90 % rated voltage and with winding at operating temperature 0 1 2 3 S [mm] 4 stroke s = 0 corresponds to armature in fully home position
Magnet Hauptkatalog
108
Main catalogue
Hochleistungs-Hubmagnet RM 32
Stoende und ziehende Ausfhrung
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Steckhlsenanschlu A 2,8 DIN 46247 Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)
RM RM
DC 24V
F 32- ED RM 100%
Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 B 150 Prfspannung: 800 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Waagerechte Kennlinie auf Anfrage. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
M4 18
Insulation group according to: VDE 0110 B 150 Test voltage: 800 V (eff) Service-free DU armature bearing for maximum durability. Linear force vs. stroke output optional. Return spring optional.
M4 M3
Mae im bestromten Zustand 10 > Hubrichtung Zul. rel. Einschaltdauer (ED)2) Nennaufnahme P 20 Anzugszeit (ED)
2)
4 11 45 94 100 65 29 70 10
2 24
10
18 24 32 15 48 5 122 11
2)
Dimensions given with armature in fully home position > Direction of stroke % W ms Perm. duty cycle (ED)2) Nominal coil power P 20 Actuation time (ED)
% W ms
45 16
25 24
Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) %ED
If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)
100 50 F [N]
20
Kraft-Weg-Diagramm F = f (s)
10 5 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand
5 10 15 25 50 100
2 1
Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature stroke s = 0 corresponds to armature in fully home position
6 S [mm]
Magnet Hauptkatalog
109
Main catalogue
Hochleistungs-Hubmagnet RM 40
Stoende und ziehende Ausfhrung
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Steckhlsenanschlu (6,3 DIN 46247) Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)
RM RM
0 C1 VD 24
-F D E 40 RM 0 %
Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 C 300 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Waagerechte Kennlinie auf Anfrage. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
Insulation group according to: VDE 0110 C 300 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Linear force vs. stroke output optional. Return spring optional.
% W ms
100 11 36
75 13,5
45 21
25 34
15 54
5 165 11
2)
% W ms
Perm. duty cycle (ED)2) Nominal coil power P 20 Actuation time (ED)
Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) %ED
If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)
100 50 F [N]
5 15 25 45 75 100
20
Kraft-Weg-Diagramm F = f (s)
10 5 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand
2 1
Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature 0 2 4 6 S [mm] 8 stroke s = 0 corresponds to armature in fully home position
Magnet Hauptkatalog
110
Main catalogue
Hochleistungs-Hubmagnet RM 40
Stoende und ziehende Ausfhrung
22
M5
M5
12 16
5 45 110
2 32
12
20 22 30 40
Dimensions given with armature in fully home position > Direction of stroke
Magnet Hauptkatalog
111
Main catalogue
M4
Magnet Hauptkatalog
112
Main catalogue
mm
mm
bis 160 mm auf Anfrage Waagerechte Kraft-Weg-Kennlinie Ausfhrung2) Hubbegrenzung Stel Flansch ohne mit rechts3) beidseitig ohne rechts3) links4) Faltenbalg ohne rechts3) links4) beidseitig5) Anschluart Litze (Standardlnge 20 cm) Gertestecker6) Nennspannung 24 V DC 205 V DC (an 230 V AC nach SI-Gleichrichterbrcke)
1601) W O H R B O R L O R L B F N 24 205
160 mm optional Horizontal frontal force vs. stroke output Description2) Stroke limit Plunger Flange without with right hand side3) both sides without right hand side3) left hand side4) Gaiter without right hand side3) left hand side4) both sides5) Coil terminals Flying leads (20 cm standard length) plug-in socket connection6) Operating voltage 24 V DC 205 V DC (connected to 230 V AC with SI- bridge rectifier)
Zulssige relative Einschaltdauer bei Luftkhlung (LK) Bis 160 mm auf Anfrage 2) Siehe unten 3) Entgegengesetzt zur elektr. Anschluseite 4) An der elektr. Anschluseite 5) Nur mit Hubbegrenzung lieferbar 6) Fr Steckhlse 6,3 DIN 46247 und Gertesteckdose Z 801 und Z 811 Zubehr siehe Seite 130-131 ca.12
1)
100 % ED Perm. duty cycle under air cooled conditions (LK) Up to 160 mm optional See below 3) Opposite to electrical connection 4) Same side as electrical connection 5) Available only with stroke limit 6) For plug-in socket 6.3 DIN 46247 and plug Z 801 and Z 811 Accessories see pages 130-131
2) 1)
200 +15
ca.12
Anschluarten
Coil terminals
Examples of design types: without end stop without stoke limit in the open position
OBOO
OBLO
OBOR
ORRO
OROR
HBOO
HBLO
HBOL
HRRO
HROR
Magnet Hauptkatalog
113
Main catalogue
Hochleistungs-Hubmagnet RM 050
Heavy duty linear solenoid RM 050 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 C 450 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 10 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
Insulation group according to: VDE 0110 C 450 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 10 mm. Return spring optional.
% W ms
100 20 40
60 30
35 55
25 70
15 115
5 300 15
1)
% W ms
Perm. duty Cycle (ED)1) Nominal coil power P 20 Actuation time (ED)
Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 1000 500 %ED
If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)
200
Kraft-Weg-Diagramm F = f (s)
100 W = Waagerechte Kennlinie 50 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] 5
20 10 0
15 W = horizontal characteristic 25 35 Force measured when operating in horizontal 60 position, at 90 % rated voltage and winding at operating temperature 100 2 4 6 8 S [mm] 10 stroke s = 0 corresponds to armature in fully home position
Magnet Hauptkatalog
114
Main catalogue
Hochleistungs-Hubmagnet RM 050
ohne Anschlagdeckel
M5 32 16
34
5 5
50
50
17
135
57
Direction of stroke
41
Hubrichtung
16
M5 M4 4,8 19 30 30
50 40 30
36
mit Anschlagdeckel
M5 32 16
34
50 42
Direction of stroke
65
Hubrichtung
10
32
28 16
65
72
30 M4
50 40 30
19 30
4,8
M5
34
Magnet Hauptkatalog
115
50 42
Main catalogue
Hochleistungs-Hubmagnet RM 060
Heavy duty linear solenoid RM 060 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 C 450 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 12 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
Insulation group according to: VDE 0110 C 450 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 12 mm. Return spring optional.
% W ms
100 25 45
40 60
25 98
15 150
5 381 17
1)
% W ms
Perm. duty Cycle (ED)1) Nominal coil power P 20 Actuation time (ED)
Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 1000 500 %ED
If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)
200
Kraft-Weg-Diagramm F = f (s)
100 W = Waagerechte Kennlinie 50 F [N] Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand
5 15 25 40 100
20 10 0
Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature stroke s = 0 corresponds to armature in fully home position
10
12 S [mm]
15
Magnet Hauptkatalog
116
Main catalogue
Hochleistungs-Hubmagnet RM 060
ohne Anschlagdeckel
M6 M6 41 18 36
5 7
152
65
17
64
72
Direction of stroke
Hubrichtung
37 18
M6 35 5,8 M5
34 29
36
60 45 35
19 30
mit Anschlagdeckel
67 54
M6 M6 41 18 36
Direction of stroke
Hubrichtung
82
10
34
29 18
81
89
M6 5,8 M5 35
36
60 45 35
19 30
Magnet Hauptkatalog
117
67 54
Main catalogue
Hochleistungs-Hubmagnet RM 070
Heavy duty linear solenoid RM 070 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 C 450 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 15 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
Insulation group according to: VDE 0110 C 450 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 15 mm. Return spring optional.
% W ms
100 31 54
40 78
25 121
15 198
5 472 25
1)
% W ms
Perm. duty Cycle (ED)1) Nominal coil power P 20 Actuation time (ED)
Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 1000 500 %ED
If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)
200
Kraft-Weg-Diagramm F = f (s)
100 W = Waagerechte Kennlinie 50 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N]
5 15
25 W = horizontal characteristic 40 Force measured when operating in horizontal position, at 90 % rated voltage and winding at 100 operating temperature 5 10 15 S [mm] 20 stroke s = 0 corresponds to armature in fully home position
20 10 0
Magnet Hauptkatalog
118
Main catalogue
Hochleistungs-Hubmagnet RM 070
ohne Anschlagdeckel
M8 49 20
43
5 8
177
75
20
43 20
39 10 34
74
84
Direction of stroke
Hubrichtung
M8 38 M5 7
43
70 52 38
19 30
mit Anschlagdeckel
M8 49 20
43
80 62
Direction of stroke
Hubrichtung
10
39
34 20
10
103
94
93
M8 38 M5 7
43
70 52 38
19 30
Magnet Hauptkatalog
119
80 62
Main catalogue
Hochleistungs-Hubmagnet RM 080
Heavy duty linear solenoid RM 080 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 C 450 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 20 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
Insulation group according to: VDE 0110 C 450 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 20 mm. Return spring optional.
% W ms
100 37 75
45 94
25 149
15 226
5 685 34
1)
% W ms
Perm. duty Cycle (ED)1) Nominal coil power P 20 Actuation time (ED)
Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 1000 500 %ED
If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)
200
Kraft-Weg-Diagramm F = f (s)
100 W = Waagerechte Kennlinie 50 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand F [N] 15 25 45 100
20 10 0
Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature 5 10 15 20 S [mm] 25 stroke s = 0 corresponds to armature in fully home position
Magnet Hauptkatalog
120
Main catalogue
Hochleistungs-Hubmagnet RM 080
ohne Anschlagdeckel
M10 30
50
5 9,5
65
85
84
216 45
23
9,5
50
12
96
Direction of stroke
M10
30
Hubrichtung
45
M10
50
80
62
45
M5
19 30
9,5
90 50
mit Anschlagdeckel
M10 30
65
72
Direction of stroke
9,5
Hubrichtung
110
109
241 45 30
25
48
10
M10 9,5 45
50
12
121
M10
50
80
62
45
M5
19 30
90
Magnet Hauptkatalog
121
72
Main catalogue
Hochleistungs-Hubmagnet RM 090
Heavy duty linear solenoid RM 090 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 C 600 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 25 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
Insulation group according to: VDE 0110 C 600 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 25 mm. Return spring optional.
% W ms
100 51 85
40 102
25 194
15 303
5 748 38
1)
% W ms
Perm. duty Cycle (ED)1) Nominal coil power P 20 Actution time (ED)
Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 2000 1000 700 500 %ED
If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)
Kraft-Weg-Diagramm F = f (s)
W = Waagerechte Kennlinie
200 100 50 20 10
5 15 25
40 W = horizontal characteristic 100 Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature 5 10 15 20 25 S [mm] 30 stroke s = 0 corresponds to armature in fully home position
Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand
F [N]
Magnet Hauptkatalog
122
Main catalogue
Hochleistungs-Hubmagnet RM 090
ohne Anschlagdeckel
M12 40
55
5 11
80
251
11
23
12
106
95
94
Direction of stroke
66
40
60 M12 52
Hubrichtung
55
55 9,5
M6
90
68
52
100 55
19 30
mit Anschlagdeckel
M12 40
80
80
Direction of stroke
Hubrichtung
125
11
55
40
12
53
M12 52 9,5 55
M6
12
124
90
68
52
100
19 30
Magnet Hauptkatalog
123
80
136
Main catalogue
Hochleistungs-Hubmagnet RM 100
Heavy duty linear solenoid RM 100 Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 C 450 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer. Bei Ausfhrung mit Standard-Hubbegrenzung Hub 30 mm. In Sonderausfhrung mit eingebauter Rckholfeder lieferbar.
Insulation group according to: VDE 0110 C 450 Test voltage: 2500 V (eff) Service-free DU armature bearing for maximum durability. Stroke of version with standard stroke limiter: 30 mm. Return spring optional.
% W ms
100 69 110
40 162
25 255
15 400
5 1071 45
1)
% W ms
Perm. duty Cycle (ED)1) Nominal coil power P 20 Actution time (ED)
Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen) 2000 1000 700 500 5 %ED
If solenoid is mounted directly onto a flat metal surface the duty cycle can be extended (please ask for advice)
Kraft-Weg-Diagramm F = f (s)
W = Waagerechte Kennlinie
200 100 50
15 25 40 100
Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand
F [N]
20 10 0 10 20 30 S [mm] 40
Force measured when operating in horizontal position, at 90 % rated voltage and winding at operating temperature stroke s = 0 corresponds to armature in fully home position
Magnet Hauptkatalog
124
Main catalogue
Hochleistungs-Hubmagnet RM 100
ohne Anschlagdeckel
M12 50
60
6 12
95
110
109
294
12
24
13
122
Direction of stroke
77
71 M12 58
Hubrichtung
50
65
M12 11,5
60
100
M8
76
58
110 60
19 30
mit Anschlagdeckel
M12 50
95
88
Direction of stroke
Hubrichtung
12
143
144
65 6
14
58
50
M12 11,5 58 60
100
M8
13
76
58
110
19 30
Magnet Hauptkatalog
125
88
156
Main catalogue
Hochleistungs-Umkehr-Hubmagnet URM 20
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Nennspannung (Standardspannung)1) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1)
URM URM
20 20
24 V DC
100 % ED
F 24 100 % ED
Flying leads (10 cm standard length) Nominal voltage (standard voltage)1) Perm. duty cycle under air cooled conditions (LK)
1)
Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Isolationsgruppe nach: VDE 0110 C 75 Prfspannung: 800 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer.
Insulation group according to: VDE 0110 C 75 Test voltage: 800 V (eff) Long life expectancy through plastic bobbin armature bearing.
% W ms
100 3,9 11
45 8
25 13,5
15 21
5 59 5
2)
% W ms
Perm. duty cycle (ED)2) Nominal coil power P 20 Actuation time (ED)
Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen)
If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)
100 50 F [N]
%ED
20
Kraft-Weg-Diagramm F = f (s)
5
2 Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung 1
Magnet Hauptkatalog
126
Main catalogue
Hochleistungs-Umkehr-Hubmagnet URM 20
21
21
M3
M3
1 9 20 2 55 0,2
+0,6
16 20
96 0,5
Magnet Hauptkatalog
127
SW14
M8
Main catalogue
Hochleistungs-Umkehr-Hubmagnet URM 50
Bestellformel Hubmagnet Bauart Anschluart Litze (Standardlnge 10 cm) Gertestecker1) Nennspannung (Standardspannung)2) Zulssige relative Einschaltdauer bei Luftkhlung (LK)
1) 2)
URM URM
50 50
24 V DC
100 % ED
F N 24 100 % ED
Flying leads (10 cm standard length) Plug-in socket connection1) Nominal voltage (standard voltage)2) Perm. duty cycle under air cooled conditions (LK)
1) 2)
Fr Steckhlsen 6,3 DIN 46247 Die Magnete sind auf Anfrage bis 230 V DC lieferbar
For socket 6.3 DIN 46247 Other voltages are available on request up to 230 V DC
Isolationsgruppe nach: VDE 0110 C 75 Prfspannung: 2500 V (eff) Wartungsfreie Ankerlagerung (DU-Lager) fr hchste Lebensdauer.
= 24V
0-N D M5 % E R U 100
Weight: Complete solenoid: Armature: Standard: Voltage: Flying leads: Insulation class:
Insulation group according to: VDE 0110 C 75 Test voltage: 2500 V (eff) Long life expectancy through plastic bobbin armature bearing.
% W
100 15
70 24
40 38
25 56
15 89
5 280
% W
3) Bei Montage auf eine Khlflche ist eine hhere ED zulssig (bitte anfragen)
3) If solenoid is mounted directly onto a flat metal surface, an increase in relative duty cycle is permissible (please ask for advice)
1000 500
%ED
200
Kraft-Weg-Diagramm F = f (s)
100 50 F [N] Kraft bei waagerechter Bewegungsrichtung und bei 90 % Nennspannung und betriebswarmer Wicklung Hub s = 0 entspricht dem angezogenen, bestromten Zustand
5 15 25 40
20 10 0
Force measured when operating in horizontal 70 position, at 90 % rated voltage and with winding at 100 operating temperature 2 4 6 S [mm] 8 stroke s = 0 corresponds to armature in fully home position
Magnet Hauptkatalog
128
Main catalogue
Hochleistungs-Umkehr-Hubmagnet URM 50
ca.52
30 19
M5
M5
30
104 156
40 50
Magnet Hauptkatalog
129
M4
ca.72 ca.60
15
15
Main catalogue
Gertesteckdose Z 801 Kabelverschraubung SPG 9 fr Kabeldurchmesser 6-8 mm Gertesteckdose Z 811 Gertesteckdose mit eingebautem Si-Brckengleichrichter Typ GDML 211-GB 1 Zu beziehen bei: Firma Richard Hirschmann Postfach 110 73728 Esslingen
53 PG9 16
Plug-in socket for the appliance Screw joint PG 9 for lead diameter 6-8 mm Plug-in socket Z 811 Plug-in socket with built-in Si-bridge rectifier Type GDML 211-GB 1 Obtainable from: Firma Richard Hirschmann PO Box 110 73728 Esslingen
22,5
27,5
3,5
M3
35
L K A
Bestellbezeichnung
BestellNr. Z 839 Z 840 Z 841 Z 842 Z 843 Z 844 Typ RM 050 RM 060 RM 070 RM 080 RM 090 RM 100 Mae (mm) A 50,0 70,0 80,0 90,0 100,0 110,0 B 7,0 8,0 10,0 12,0 12,0 13,0 C 12,0 13,0 15,0 17,0 17,0 19,0 D 30,0 35,0 38,0 45,0 52,0 58,0 E 23,0 29,0 32,5 38,0 43,0 49,0 F 30,0 35,0 38,0 45,0 52,0 58,0 G 60,5 70,5 80,5 90,5 100,5 H 1,0 1,0 1,0 1,0 1,0 I 4,8 5,8 7,0 9,5 9,5 11,5 J 4,3 5,3 5,3 6,4 6,4 8,4 Dimensions (mm) K 42,0 54,0 62,0 72,0 80,0 88,0 L 40,0 45,0 52,0 62,0 68,0 76,0
G F E H
Order specification
Order Type RM 050 RM 060 RM 070 RM 080 RM 090 RM 100 number Z 839 Z 840 Z 841 Z 842 Z 843 Z 844
Magnet Hauptkatalog
130
Main catalogue
H J G
I B A
K D C
Bestellbezeichnung
BestellNr. Z 838 Z 845 Z 846 Z 847 Z 848 Z 849 Typ RM 050 RM 060 RM 070 RM 080 RM 090 RM 100 Mae (mm) A 50,0 60,0 70,0 80,0 90,0 100,0 B 40,0 45,0 52,0 62,0 68,0 76,0 C 20,0 22,0 24,0 30,0 35,0 40,0 D 15,0 17,0 19,0 25,0 30,0 34,0 E 23,0 29,0 33,0 38,0 43,0 48,0 F 30,0 35,0 38,0 45,0 52,0 58,0 G 5,5 5,5 5,5 5,5 5,5 6,5 H 11,0 12,0 15,0 20,0 25,0 30,0 I M4 M5 M5 M5 M6 M8
E F
Order specification
Dimensions (mm) J 4,3 5,3 5,3 5,3 6,4 8,4 K 10,0 10,0 10,0 10,0 12,0 14,0 Type RM 050 RM 060 RM 070 RM 080 RM 090 RM 100 Order number Z 838 Z 845 Z 846 Z 847 Z 848 Z 849
Gabelkopf
Fork
BestellNr. Ordernumber
1)
A 12 23 27 32 40
B 15 29 34 42 52
C 9 16 19 26 32
F 6 10 12 16 20
2)
Gabelkpfe, verzinkt und gelb chromatiert, werden ohne Mutter geliefert. Sicherung z. B. durch Loctite o.. Weitere Ausfhrungen (> M10) auf Anfrage
2,5 3,1 5 6 8 10 5 6 8 10
Forks are galvanised and chromed yellow. Supplied without a nut. Secure using e.g. Loctite or a simular product. Further specifications (> M10) optional
Magnet Hauptkatalog
131
Main catalogue
Magnet Hauptkatalog
132
Main catalogue