1. RUN AUTO INSPECTION


Run AUTO INSPECTION. 1. Menu [Mode] [Inspection Mode]

2. Open the [Inspection Mode]

X-ray Automatic Vision Inspection System

2. AUTO INSPECTION
[AUTO INSPECTION] explain if had setting model file. 1. Fix the samples on the ZIG at designated areas. 2. Run [Inspection Mode].

3. Change [Effect Control] [Adjust.] [AUTO_G].

X-ray Automatic Vision Inspection System

2. AUTO INSPECTION
4. Setting the camera control as 5. Click X-ray on and set Voltage and Current for inspection.

** If change inspection voltage and current, Click

and save inspection vol. and cur. .

6. After find the brightness of image automatically, [Image effect] [Control brightness] [NONE].

X-ray Automatic Vision Inspection System

2. AUTO INSPECTION
7. Click button to open setting area on [Auto Inspection]. button at [Auto 8. Open the set model before. Click Inspection]. 9. Click the file that you want to see and Open the required Click button. data like image
beside.

X-ray Automatic Vision Inspection System

2. AUTO INSPECTION
10-1.Want to inspect the image that showing case. Grab the image that want to inspect, and Click at [Auto Inspection] 10-2. Want to inspect the image that saved before case. Click at [Auto Inspection] and open the images. 11. Click , if opened setting value and the image that you want to inspect.

X-ray Automatic Vision Inspection System

2. AUTO INSPECTION
12. Inspect distance of Die-casting.

** Reference articles 1 Control brightness of Image effect; No need to do every time below. [AUTO_G] [NONE] because, this is for finding suitable brightness value. But the condition is changed, then need to do. ** Reference articles 2 Can inspect other image even though, the setting value is open. Just click after open the saved image.

X-ray Automatic Vision Inspection System

2. AUTO INSPECTION
Explanation of inspection display picture.

Area of result mark

Area of work indication Area of inspection setting

X-ray Automatic Vision Inspection System

3. A.I MODEL SETTING


A.I MODEL SETTING means explanation of setting button.
SAVE DIR Designate folders location of all saved images at [AUTO INSPECTION]. Save as folder for save images with click button.

Open Image Open Image RESULT MODE Mark that want during inspect.

LOAD MODEL Open the designated setting value.

SAVE MODEL Save setting value as you want (location, name,,)

SAVE X-RAY Save the designated X-ray voltage and current value at loading setting model. It is useful to get images with same value and condition.

X-ray Automatic Vision Inspection System

4. A.I SETTING PARAMETER


A.I SETTING PARAMETER is explain the meaning of setting parameter.
PARAMETER Designate applicable brightness value each parts.
* Applicable brightness value is ; Check pixel value with click [Image Control] [Pix.] Detect2. Pixel value of inside boundary surface. Detect1. Pixel value of outside boundary surface.

ROI SETTING Possible setting Qty of inspection area. (max.10 EA)


Gap Distance between Detect1 and Detect2.

SCALE MIN Pixel value is less than scale min. In that case, it set the pixel value at 0.

SCALE MAX Pixel value is more than scale max. In that case, it set the pixel value at 255.

DETECT1 Pixel value of outside boundary surface.

DETECT2 Pixel value of inside boundary surface.

Gap Min Acceptable minimum distance.

Gap Max Acceptable maximum distance.

GAP

X-ray Automatic Vision Inspection System

5. SAVE INSPECTION IMAGE


Save image and inspection result. 1. Designate the folder that will be saved with click button.

2. After designate image file name and file type at [Save Inspection Result] click button. 3. Will be saved with image and inspection result value as the image beside.