Académique Documents
Professionnel Documents
Culture Documents
Telecommunications, machine construction, measurement and control systems, automotive electronics, building security and installation today there is virtually no branch of human activity that can exist without using modern relays. Matsushita is able to meet both simple or complex demands from its vast range of sophisticated, economic switching technologies by offering the relay most appropriate to solving the specific application. Economic and technical competence. With over 30 years experience at the forefront of relay innovation and development, Matsushita today offers one of the world`s most comprehensive ranges of electro-mechanical and semi conductor types. Currently the Matsushita product range extends from ultra-miniature SMD semi conductor types to robust, compact industrial devices. Load switching capability ranges from low-level signals to double digit ampres. Application dependent, Matsushita relays are available for all common mounting configurations with screw, pcb, solder or surface mount terminals to meet most of the demands made by different operating environments or conditions. A principal area of application for the modern relay is in the already booming market of telecommunications. With its well established, comprehensive T-series relay ranges, and the new GN/GQ 4th generation telecom relays, Matsushita is making significant contributions within the field of global data transmission.
Matsushita power relays, particularly those of the J-series are not only used in mains isolation applications, but also in diverse ranges of consumer appliances, automotive electrics and diverse OEM manufacturing industries. In the field of safety of man and machine, the introduction of SF2, SF3 and SF4 relays, with forced operated contacts has set a new standard of security. Matsushita has developed a wide range of SMD miniature relays for the new-generation of surface mounting, automated assembly processes. In addition to electromechanical SMD types such as TQ, TX, GN and GQ series Matsushita has made significant developments in the rapidly expanding field of PhotoMOS semi conductor relays. With the AQV212 SOP type, Matsushita is able to supply what is currently one of the smallest semi conductor relay. Measuring just 2,1 mm high this type reflects the extent to which electronics and communication systems are being miniaturised. Quality to ISO9001 standards. For Matsushita the supply of quality products is paramount. To achieve this the Company implement strict test and inspection procedures to comply with most international specifications. The award of ISO9001 certification has set the seal on our production capabilities. If you need more detailed information about Matsushita relays please ask us to send you a full relay catalogue. Matsushita Relays. Ideas for Tomorrow`s World.
CONTENTS
PAGE 4 5 8 8 4 5 6 4 9 8 9 4 9 7 6 7 6 5 5 6 7 7 11 11 10 11 10 11 10 10 12 12 12 13 14 15 15 15 14 JA relay JC relay JE-X relay JG/JG-P relay JK relay JM relay JQ relay JR1aF relay JS relay JV relay JW relay JY relay JZ relay LA relay LD relay LE relay NEW ! LF relay NEW ! LK, LK-P, LK-S relay MC mini contactor NC relay NT relay PA/PAD relay PE relay PQ relay RT3 relay terminal SP relay ST relay VC relay AUTOMOTIVE RELAYS CA relay CB relay CF relay CM relay CP relay CQ relay CT1/2/5 relay EV relay JJM(2W) relay JSM relay JT/JTN relay 18 17 15 16 17 19 16 19 16 16 16 18 18 17 17 18 19 17 19 13 14 12 13 13 13 14 12 19 21 22 21 22 20 20 21 22 20 21 22 SAFETY RELAYS SF2 relay SF3 relay SF4 relay TIME DELAY RELAYS TR time delay relay TS time delay relay MODULES VS module IC module PhotoMOS Technology PhotoMOS Overview PhotoMOS Signal Relays 1 channel type 1NO contact 1NC contact Low cost types 2 channel type 2NO contact 2NC contact 1NO/1NC contact Low cost types Special types POWER PhotoMOS Relay PhotoMOS for High Frequency PhotoMOS Multifunction types PhotoMOS Linear Coupler 23 23 23 24 24 25 25 26 30 32 32 36 37 39 40 40 41 43 44 48 51 52
SIGNAL RELAYS A relay DF relay DS2-E(F)[S]/DSBT relay DSE-M(S) / DS2Y-S relay DX relay GN/GQ relay HX2 / HX2-SA relay HY relay K relay NF relay NL relay R relay S relay SX / SX2-SA relay TF2 relay TK1 relay TN2 relay TQ2 relay TQ2-SA relay TX2 / TX2-SA relay TXS2 / TXS2-SA relay TX-D2 / TX-D2-SA relay HIGH-FREQUENCY RELAYS RA relay NEW ! RD relay RE relay NEW ! RG relay RK relay RM relay RP relay RX relay POWER RELAYS DE relay DK relay DSP relay HA relay HC/HJ relay NEW ! HE relay HG relay HL relay HP relay
S
Type
N
A
L
HY
L
R
S
DX
9.5 x 20 Reed relay with single-in-line pcb pins Can also be mounted flat Not for a new design-in
b
20 x 10 x 10.2 Polarised monostable or bistable (latching) reed changeover relay Outstanding reliability VS-compatible IC-compatible Not for a new design-in 1CO
b b b b b
20 x 12 x 6.3 Metal encapsulated miniature relay For dry load or HF circuits Sealed to IP68 IC-compatible VS-compatible
b b b b
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
1NO
1CO
2CO
Maximum
0.1
Minimum
0.1 60 125 monostable 500 1000 1.5 24 sensititive: 150; standard: 200 IP67
0.001 30 110 monostable, bistable 350 1000 1000 1.5 60 150 280 70 100 150 230 IP67
0.001 30 110 monostable, bistable 500 500 500 3 24 125 144 125 144 250 288 IP68
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
PCB
PCB
S
Type
N
DF
R
GN/GQ
A
TQ2
S
TQ2-SA
16 x 9.9 x 7 Polarised DIL relay 8 cN dual contact force 1 2 V thermovoltage for dry load or power switching BT type 53 version available IC-compatible VS-compatible Not for a new design-in 2CO 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC 0.1 60 125 monostable, bistable Vrms Vrms Vrms 500 500 1000 1500 1.5 24 200 100 200 IP67
14 x 9 x 5
b b
14 x 9 x 5.6
b b b b
b b
Extremely compact ultraminiature relay 2 changeover contacts Very high impulse voltage withstand 2.5 kV complying Bellcore standard High density mounting due to decreased relay size. IC-compatible 2 CO
b b
Ultra-miniature relay Universal performance capability for use in telecommunications, measurement and instrumentation IC-compatible VS-compatible 2CO
New, very low profile SM version 2 changeover contacts 2 A switched current Very high impulse voltage withstand 2,5 kV complying with Bellcore standard IC-compatible, VS-compatible 2CO
Maximum
Minimum
0,01 110 125 monostable, bistable 750 1000 1500 2500 Bellcore 1.5 24 140 230 100 120 IP67
0.01 110 125 monostable, bistable 750 1000 1000 1500 1.5 48 140 300 100 150 200 300 IP67
0.01 220 125 monostable, bistable 1000 1000 1500 2500 Bellcore 1.5 48 140 300 70 100 140 200 IP67
Switching configuration Open contact Voltage withstand Between contact sets Coil / contact
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
S
Type
N
TN2
L
TF2
L
HX2
S
TX2 / TX2-SA
14 x 5.6 x 9.8 Ultra-miniature relay Upright version of TQ High packing density due to very small footprint IC-compatible VS-compatible 2CO 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC 0.01 110 125 monostable, bistable Vrms Vrms Vrms 750 1000 1000 1500 3 48 140 300 100 150 200 300 IP67
b b b b
15 x 7.4 x 8.2 High efficiency ultra-miniature relay SM version Very high impulse voltage withstand 2.5 kV complying with Bellcore standard IC-compatible VS-compatible 2CO
b b
b b
2CO
2CO
Maximum
Minimum
0.01 110 125 monostable, bistable 750 1000 1000 1500 3 48 80 260 55 100 110 200 IP67
0.01 110 125 monostable 750 1000 1000 1500 1.5 24 320 IP67
0.01 220 220 monostable, bistable 1000 1000 2000 2500 Bellcore 1.5 48 140 270 100 200 IP67
Switching configuration Open contact Voltage withstand Between contact sets Coil / contact
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
S
Type
R
TX-D2 / TX-D2-SA
S
TK1
TXS2 / TXS2-SA
SX2/SX2-SA
15 x 7.4 x 8.2 (8.4) High sensitive relay (50mW) Low thermal electromotive force (approx. 0.3 V) Surge voltage withstand of 1500 V FCC 2CO 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC 0.01 110 125 monostable, bistable Vrms Vrms Vrms 750 1000 1800 1500 1.5 24 50 70 35 50 70 150 IP67
b b
15 x 7.4 x 8.2 Approved to EN41003 supplementary isolation Very high surge resistance
1500 V 10 x 160 s (FCC part 68)
b b b
15 x 7.4 x 8.2 Low level switching capability (10 A 1m V DC) High sensitivity (50 mW)
b b
10.6 x 9 x 4 Smallest relay with 2 A capability Very high impulse voltage withstand 2.5 kV complying with Bellcore standard IC-compatible
2500 V 2 x 10 s (Bellcore) 2000 V breakdown voltage Also available for MBB 2CO (MBB) 2CO
2CO (BBM)
1CO
Maximum
0.01
Minimum
220 250
125 125
0.01 220 220 monostable, bistable 750 1000 1500 2500 Bellcore 1.5 24 140 270 100 150 200 400 IP67
Switching configuration Open contact Voltage withstand Between contact sets Coil / contact
monostable, bistable 1000 1000 2000 2500 Bellcore 1.5 24 200 230 150 170 IP67 250 270 500
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
50 70 35 50 70 150 IP67
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
PCB, SM technology UL (E 43149), BSI, CSA (LR 26550), EN 60950 UL (E 43149), BSI, CSA (LR 26550)
S
Type
R
DS2E(F)/ DSBT2
L
NF
DSE-M(S)/DS2Y-S
15/ 20/ 35.2 x 9.9 x 9.8 Dimensions of 1CO / 2CO / 4CO x 9.9 x 9.8 Universal pcb relay with large switching range M = 400 mW (S) = 200 mW version IC-compatible VS-compatible 1CO/2CO/4CO 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC 0.01 220 250 monostable, bistable Vrms Vrms Vrms 1000, DS1E-S: 500, DS2Y: 750 1000 1500, DS1E-S / DS2Y: 1000 1500 1.5 48 400, Type S: 200 180, Type S: 100 360, Type S: 180 IP67 DS 1
b b b b b b b
20 x 9.9 x 9.8 FLOC version [DS2E(F)] 12 cN contact force (F) = high sensitivity version BT = 4000 Vrms breakdown voltage DSBT also available for MBB*) BABT approvals IC/ VS-compatible 2CO
b b
Proven pcb relay High reliability due to bifurcated linear Au/ Ag contacts Not for a new design-in
2CO / 4CO
Maximum
Minimum
0.01 220 250 monostable, bistable 1000, Type BT: 750 1000 1500, Type BT: 4000 1500 1.5 48 200, Type F: 140, Type BT: 360 100, Type F: 70 200, Type F: 140 IP67
2 CO
0.1 220 220 monostable 750 1000 1000 1500 5 60 2CO: 300; 4CO: 480 IP67
Switching configuration Open contact Voltage withstand Between contact sets Coil / contact
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
DS 2, DS 2Y
4 CO
DS 4
PCB UL (E 43149), CSA (LR 26550), BABT CR No.: 0104 *) MBB = make before break
S
Type
N
NL
L
K
A
S
25.4 x 32.4 x 10.9 Flat pcb relay 6 changeover contacts Not for a new design-in
b b b b
24/ 29/ 35 x 19 x 30 Dimensions for 2CO/ 4CO/ 6CO x 19 x 30 Relay with proven cam operated Au / Ag contacts Plug-in or pcb connection Not for a new design-in
b b b b b
28 x 12 x 10.4 Wide switching range due to 5-layer contacts Good HF switching characteristics Low thermo voltage IC-compatible VS-compatible
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
6CO
2CO/4CO/6CO
Maximum
Minimum
0.01 110 110 monostable, bistable 1000 1000 2000 5 110 60 V: 720; 110 V: 900 1600 IP67
2 CO
0.1 220 250 monostable 750 750 750 3 110 2CO: 400; 4CO: 700; 6CO: 1300 IP67
4 CO
0.01 200 250 monostable, bistable 750 1000 1500 1.5 48 200 271 83 144 200 355 IP67
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
6 CO
H
Type
N
RK
R
RX
Y
RP
RE w ne
Dimensions (mm) LxWxH Features Insertion loss (max) Isolation (min) V.S.W.R. (max)
20.2x11.2x8.9/9.6
b Up to 2.6 GHz b SMD-type available b Isolation 30 dB /
10.6 x 9 x 4
b Extremely small
HF relay
b Use up to 1.8 GHz b High sensitivity b Insertion loss: 1 dB b Isolation 10 dB b V.S.W.R. 1.3 b Impedance 50
2.6 GHz
b Impedance 75
200 mW
b Isol.: 60 dB or more b Insertion loss: 0.2 dB b V.S.W.R. 1.2 b Impedance 50
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
1CO/2CO
1CO
1CO
1CO
Maximum
0.01
0.5
0.5
0.1
Minimum
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
PCB
PCB
PCB
PCB
10
H
Type
E
RA w ne
N
RM
R
RG
Y
RD
Dimensions (mm) LxWxH Features Insertion loss (max) Isolation (min) V.S.W.R. (max)
28 x 12.4 x 10.5
b Polarised miniature
25 x 19 x 10.4
b Polarised miniature
34 x 38 x 13.2
b 1 GHz 18 GHz b Insertion loss
0.2 0.5 dB
b Isolation min.
bistable (latching) b Insertion loss: 1 dB b Isolation 65 dB b V.S.W.R. 1.2 2.0 b Impedance 50 or 75 1CO/2CO
dB 60 85
b V.S.W.R. max.:
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
2CO
Maximum
0.01
100 mA
Minimum
30 24 mono-, bistable 750 1000 1000 1.5 48 140 300 70 100 140 200 IP67
24 24 mono-, bistable 1000 2000 3 48 350 400 180 200 350 400 IP67
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
2 CO
SM technology
PCB
PCB
SMA
11
P
Type
E
DSP
R
DE
E
DK
Y
ST
S
PA/PAD
25 x 12.5 x 12.5
20 x 12.5 x 10 / 20 x 15 x 10
b b b b b
31 x 14 x 11.3 Friction-free rotating armature Air gaps and creepage distances > 4 mm High voltage withstand IC-compatible VS-compatible 1NO 1NC/2NO
b b b b
20 x 5 x 12.5 Extremely small and narrow power relay Au plated Ag contacts High packing density Pin compatible to PhotoMOS AQZ relay
Small dimensions b Width for 1NO: 12.5 mm / High switching capacity 2NO and 1NO 1NC:15mm 16 A = 25.000, b Polarised miniature 10 A = 100.000 power relay operations b PCB mounting 8 mm air gaps and b 8 mm airgaps and creepage distances creepage distances b Test voltage: 4 kV 1NO/2NO/1NO 1NC 1NO 1NO/1NO 1NC/2NO
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
1NO/1NO 1NC/2NO
1NO
1NO
10/16
1NO
Maximum
Minimum
0.1 220 400 monostable, bistable 1000 2000 3000 5000 1.5 24 300 150 300 IP67
230 440 monostable, bistable 1000 4000 5000 12000 1.5 48 200 100 200 IP67
single side stable 1 coil latching
125 400 monostable, bistable 1000 4000 4000 10000 1.5 48 200 100 200 IP67
0,1 250 400 monostable, bistable 1200 2000 3750 6000 3 48 240 110 225 IP67
0.1 110 250 monostable 1000 2000 4000 5 24 120 180 IP67
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
12
P
Type
R
PE
E
HA
Y
PQ
S
NC
RT-3 module
67 x 33 x 32 Space saving relay module for DIN rail mounting b Four PA relays per module b Separate indicator LED for each relay b Also available with PhotoMOS relays AQZ type 4 x 1NO 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC 0.1 110 250 monostable Vrms Vrms Vrms 1000 2000 12, 24 180
b b b
28 x 5 x 15 Compact and small foot print area High insulation resistance meeting VDE0700 8 mm creapage and clearance distances
b b b
26.3 x 14 x 16.9 Dust tight/ sealed pcb relay AC or DC coil Also available sealed with gold contacts
b b b
20 x 10 x 15.6 Power relay with high switching capability High impulse voltage withstand High sensitivity
Dimensions of 2CO/4CO x 25.4 x 10.9 High efficiency power relay Flat or upright versions Bifurcated contacts
1NO/1CO/1NC
1CO
1NO
2CO/4CO
Maximum
Minimum
1 30 250 monostable 750 1500 5 48 6 115 DC: - 360; AC: - 900 IP50 / IP67
0.01 250 250 monostable, bistable 1000 1000 2000 5 110 2CO: 360; 4CO: 720 2CO: 800; 4CO: 1600 IP50 / IP67
Switching configuration Open contact Voltage withstand Between contact sets Coil / contact
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
2 CO
4 CO
Screw terminal
13
P
Type
E
SP
R
NT
S
HP
HC/HJ new
Dimensions for 2CO/ 3CO/ 4CO x 36 x 44 Power relay with long operational life
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms 2CO
2CO/4CO 4CO
1CO
1CO/2CO/3CO/4CO 1CO
2CO/3CO/4CO
2CO 3CO
4CO
Maximum
Minimum
10 110 250 monostable, bistable 1500 3000 3000 3 48 300 100 300 IP40
2 CO
0.1 30 250 monostable 700 700 2000 6 110 6 240 900, AC: 1200 IP50 / IP67
2CO 2 CO
1 125 250 monostable 2CO/4CO: 1000; 3CO: 2000 2CO/4CO: 1500; 3CO: 2600 2CO/4CO: 1500; 3CO: 2000 6 110 6 240 1500, AC: 1900 4900 IP50
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
3CO 4 CO 4 CO 3 CO 4CO
PCB, solder, screw VDE, UL (E 43028), CSA (LR 26550), SEV (1CO, 2CO, 3CO), TV rating
14
P
Type
E
HL
R
HG
A
HE
S
JEX
27.2 x 20.8 x 35.4 Compact power relay High operational life Wide switching range
b b
34 / 50 / 68 x 36 x 56 Dimensions for 2CO / 3CO / 4CO x 36 x 56 mm Compact power relay with up to 4 switching contacts
b b b
50 x 33 x 35.8 Compact power relay for DC or AC 8 mm air gaps and creepage distances 3 mm contact gap
b b
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms 1CO
1CO/2CO 2CO
2CO/3CO/4CO 1NO
1NO/2NO
1NO/1CO 2NO
20
30
20
Maximum
Minimum
1 30 250 monostable 1000 1500 2000 6 110 6 240 900 1000 [1.2 1.3] IP40
1CO 2CO
100 277 monostable 2000 4000 5000 10000 6 110 6 240 1920 [1.65 2.65]
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption mW [VA] Monostable Bistable 1 coil Bistable 2 coils
IP40
3CO
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
2CO
4CO
Plug-in, screw, flange TV, UL (E 43028), CSA (LR 26550), VDE, TV rating
15
P
Type
W
JQ
R
JS
E
JW
Y
JV
S
JG / JG-P
20 x 10 x 15.6 Low power consumption Very low cost High impulse voltage withstand
b b b b b
22 x 16 x 16.4 Universal miniature power relay High switching capability Very suitable for automotive applications Special type for high ambient temperatures Very low cost 1NO/1CO
b b
28.6 x 12.8 x 20.4 Compact mains isolation b relay Air gaps and creepage distances > 7.5 mm bet- b ween contacts and coil b Test voltage 5000 Vrms between contacts and b coil 1NO/1CO/2NO/2CO 1NO 1CO 1NO 1CO 2NO 2CO
22 x 16 x 10.9 High switching capability within low profile small package High sensitivity Suitable for automotive applications Flat construction 1NO/ 1CO 1NO
b b
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
1NO/1CO
1NO
16
1CO, 1NO
Maximum
Minimum
Standard version
Power version
Power version
Standard version
110 250 monostable 1NO: 1000, 1CO: 750 4000 8000 3 48 1NO: 200, 1CO: 400 IP67
1NO 1NO
110 250 monostable 1000 1500 5 100 200 450 IP50 / IP67
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
1NO
1CO
JG/JG-P
1CO
1CO
2NO
1CO
3.12 .123
JG-P
2-2 dia. 2-0.9 dia. 2-.079 dia. 2-.035 dia.
2CO
6 .236
10.16 .400
25.4 1.000
16
P
Type
W
JC
R
JK
E
LD
Y
LA
S
LK/LK-S/LK-P
30 x 19 x 30.4 8 mm air gaps and creepage distances High make current capability 2 NO spezial type with blow magnet for 250 V DC / 5 A 1NO/2NO/ 1NO 1NC 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC 125/250 with blow magnet VAC 250 monostable Vrms Vrms Vrms 2000 2000 4000 10000 6 48 1NO: 900, 2NO / 1NO 1NC: 1000 IP40 1NO 2NO 1NO 1NC
b b
21.4 x 11 x 15.7 Small, narrow pcb relay JK-Q quiet (30dB) switching noise
b b b
20.5 x 7.2 x 15.3 Slim 7 mm width 200 mW operating power 6 mm creapage distance and clearances
b b b
24 x 12 x 25 Low-cost power relay Surge withstand voltage 10 kV 6 mm creapage distance and clearances 3 A type best suited for switching speakers 2NO
b
24 x 11 x 25 High switching capacity 20 A 277 V AC 111A inrush current capacity Surge withstand at 10000V 1NO
b b
1NO
1NO
Maximum
Minimum
LK LK-S
LK-P
Switching configuration Open contact Voltage withstand Between contact sets Coil / contact
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
2NO
(1.05) (1.15)
11.5
7.0
4-1
2NO/1NO 1NC
4.7
17
P
Type
E
LE new
R
JZ
E
JY
Y
JA
28.6 x 12.4 x 24.9 Relay for home appliances Excellent heat resistance (+85C ambient) Low operating power #187 terminals 1NO 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC 277 monostable Vrms Vrms Vrms 1000 4000 10000 5 48 400 IP40
4-1.3 dia .071 dia 3.5 .138
22 x 14 x 11.6
b b b
22 x 12 x 22.5
b b b
Small pcb relay High impulse voltage withstand Special type for low switching noise (30dB)
Compact pcb relay High switching capability Special type for high ambient temperatures
b b
High switching capability FAST-ON connections for contacts Plug-in or pcb (TMP) connections for coil Max. make current 55 A 1NO/1NC/1CO
1NO
1NO/1CO
Maximum
Minimum
110 250 monostable 750 2000 10000 5 24 200 400 IP50/ IP67
100 250 monostable 1000 2000 5000 6 24 6 115 1200, AC: 1300 IP67
Switching configuration Open contact Voltage withstand Between contact sets Coil / contact
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
7.5 .295
20.0 .787
18
P
Type
R
JM
L
LF w ne
Y
MC
S
VC
JR1aF
28.6 x 12.8 x 28.5 According Isolation VDE0660 with 8 mm air gaps and creepage distances Test voltage 5 kV
b b b
30.4 x 16 x 26.5 Relay for large motor loads High impulse voltage withstand Make current up to 70 A
b b b
30.1x 15.7x 23.3 For compressor or motor loads Air and creepage distance > 8 mm 102 A inrush current / 200 V AC
b
45 x 45.2 x 40 Minicontactor for controlling motor, airconditioning and heating loads Energy saving Also available in PCB version 3 mm contact opening
b
b b b
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
1NO
1NO
1a
16
20
25 16
20
Maximum
Minimum
110 277 monostable 1000 3000 5000 10000 6 48 115 530 IP50
440 400 monostable, bistable 2500 2500 2500 3 48 24 380 500 IP40
2NO 2NC 3 NO (2NO 1 NC)
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption mW [VA] Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
3NO 1NC
2NO 2NC
12.0 0.1 .472 .004 10.0 0.1 .394 .004
4NO
Top mount contact, coil to pcb UL (E 43028), CSA (LR 26550), TV 88121645536, VDE 3584
19
A
Type
O
CP
V
CQ
E
JJM
Y
JJM2W
14 x 13 x 9.5
b Ultra miniature
17 x 13 x 16.6
b Quiet type
15.5 x 12 x 13.9
b Miniature power relay b Typical application:
15.5 x 12 x 13.9
b Double make
automotive relay
b High carrying current
and high temperature capabilities b High inrush current capability (40A, lamp load) b Available in SMD version Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms 16 monostable 500 500 12 640 IP67
1NO
air conditioning systems, power window door lock b New: double make 1a contact arrangement 1NO / 1CO 1NO 1CO (NO) 20 1CO (NC)
1NO / 1CO NO
1CO
2W (2 x 6 A) lampload
20
20
NC
Maximum
Minimum
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
4-1.4 dia
4-1.4 dia
4-1.4 dia
1CO
1.5 dia 2.5 10.2
10.0
2.5
10.2
2.5
10.2
Tolerance : 0.1
Tolerance : 0.1
Tolerance : 0.1
PCB, SM technology
PCB
PCB
PCB
20
A
Type
O
CT1/2/5
V
CF
E
CA
Y
JSM
26.2 x 19.4 x 40
b
22 x 16 x 16.4
b Miniature power relay
Narrow automotive relay Available in single/ twin/dual coil packages All types are footprint compatible
b b b
Power relay for automotive applications 2 separate coils in a single housing For high DC current Low noise < 50 dB type available 2 CO (H-bridge)
JSM-4 for max. make current 25 A b High power version JSM-5 for max. make current 50 A 1NO/1CO
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
1CO/2CO(H-bridge)/2 x 1CO
1NO
20
20
20
Maximum
JSM-4
JSM-5
Minimum
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
CT5
1CO CT2
PCB
PCB
Flat plug-in
PCB
21
A
Type
O
JTN
V
CM
E
CB
Y
EV
20 x 15 x 22
b b b
26 x 22 x 25
b b b b
88 x 87 x 87
b
80 x 38 x 71
High switching capability Up to 30 A lamp load Sealed and TMP types available
35 A contact rating High temperature range -40C to +85C High shock resistance for drop test requirements Quick connect and PCB type 1NO/1CO
40 A automotive relay High shock withstand Low contact losses 1 NO power type for 70 A available 1NO/1CO
b b
Power capsule contact relay for electric vehicle, hybrid electric vehicle Safety, small construction DC power cutt-off with compact body
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
1NO/2NO
1NO
30
20
35
40 20
30
150
60
30
1CO (NC)
Maximum
Minimum
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
1CO
22
S
Type
T
SF2/SF2D
h new wit ontacts c e l b u do
Y
SF3
L
SF4/SF4D
53.3 x 25 x 16.5 Polarised relay with forced operated contacts according to EN 50205 min. 10 V / 10 mA D = Double contacts
b
53.3 x 25 x 16.5 Polarised relay with forced operated contacts according to EN 50205 min. 10 V / 10 mA
b
53.3 x 33.4 x 16.5 Polarised relay with forced operated contacts according to EN 50205 min. 10 V / 10 mA D = Double contacts
b b
b b
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
2NO 2NC
3NO 1NC
4NO 4NC
Maximum
Minimum
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
23
Type
TR
TS
30.4 x 22.1 x 10.7 Universal adjustable pcb time delay relay for ON or OFF delay, pulse or wiper action Also available for external remote adjustment
b
34 x 34 x 10.8 Universal adjustable pcb time delay relay for ON or OFF delay, pulse or wiper action Also available for external remote adjustment
Pull-in delay: 0,1 10 s; 1 100 s; 8 800 s; Pull-in delay: 0,1 10 s; 1 100 s; 8 800 s; 11000 s for external Potentiometer 11000 s for external Potentiometer Release delay: 0,1 10 s or Release delay: 0,1 10 s or 0,3 100 s with external Potentiometer 0,3 100 s with external Potentiometer
Contact arrangement Switched load range (resistive load) 15 A 10 A 8A 5A 3A 2A 1A 1 mA 100 A 10 A VDC VAC Switching configuration Open contact Voltage withstand Between contact sets Coil / contact Vrms Vrms Vrms
1CO
Maximum
Minimum
Impulse voltage withstand (1.25 / 50 s) V Nominal coil voltage VDC VAC Power consumption (mW) Monostable Bistable 1 coil Bistable 2 coils
Degree of protection Connection diagram (Bottom view) Pin grid 2.54 mm unless stated otherwise b Coil connection
PCB
PCB
CE
CE
24
North & South America USA Asia China Hong Kong Japan Singapore Matsushita Electric Works, Ltd. China Office, 2013, Beijing Fortune, Building No. 5, Dong San Huan Bei Lu, Chaoyang District, Beijing, Tel. 86-10-6590-8646, Fax 86-10-6590-8647 Matsushita Electric Works Ltd. Hong Kong, Rm1601, 16/F, Tower 2, The Gateway, 25 Canton Road, Tsimshatsui, Kowloon, Hong Kong, Tel. (852) 2956-3118, Fax (852) 2956-0398 Matsushita Electric Works Ltd. Automation Controls Company, 1048 Kadoma, Kadoma-shi, Osaka 571-8686, Japan, Tel. 06-6908-1050; Fax 06-6908-5781, http://www.mew.co.jp/e-acg/ Matsushita Electric Works Pte. Ltd. (Asia Pacific), 101 Thomson Road, #25-03/05, United Square, Singapore 307591, Tel. (65) 255-5473; Fax (65) 253-5689
Printed in Germany Copyright 1999 1060 eu en 03/01
Aromat Corporation Head Office USA, 629 Central Avenue, New Providence, N.J. 07974, Tel. 1-908-464-3550, Fax 1-908-464-8513, http://www.aromat.com