C ATA LOG U E OF INSTRUMENTS

MEASURING INSTRUMENTS BARGRAPHS LARGE DISPLAYS TRANSMITTERS TO DIN RAIL

l a y s
t

m
it

t
e
r

m
r i n g s u e a
i n s t r u m e n t

PANEL MEASURING INSTRUMENTS


2008.1

ORBIT MERRET 2008.1 en

Rate (measurement/s)

AO/Data/Exc.

Power supply

Accuracy (% of range)

Digital lters

Height (mm)

Dimensions (mm)
48 x 24 72 x 24 96 x 48 96 x 48 96 x 24 96 x 48 96 x 48

Projection

Excitation

Functions

OM Link

Analog

Limits

OMM 37DC

1999 1999 1999 1999 19999 19999 9999

9,1 9,1 14 14 14 14 14

Pehled
OMM 350DC OM 36DC OM 352DC

199,9 mV199,9 V 199,9 A199,9 mA 20/40/100/200 V 1/5 A 199,9 mV300 V 199,9 A5 A 20/40/100 V/200 V 1/5 A 1,9999 V199,99 V 199,99 A199,99 mA 199,99 mV300 V 199,99 A5 A 60 mV500 V 1 A5 A 99,999 mV300 V 999,99 A5 A 199,9 mV300 V 199,9 mA5 A 000,6/0,3/24/50/90/120/ 250/450 V 01 A/5 A 199,99 mV300 V 199,99 mA5 A 2 V; 5 V, 10 V 5 mA; 20 mA; 420 mA 02/5/10 V 020/420 mA 2 V; 5 V, 10 V 5 mA; 20 mA; 420 mA 02/5/10 V 020/420 mA 2 V; 5 V, 10 V 5 mA; 20 mA; 420 mA 2 V; 5 V, 10 V 5 mA; 20 mA; 420 mA 14 inputs 2 V/5 V/10 V/040 V 5 mA/20 mA/420 mA 2 V/5 V/10 V 5 mA/20 mA/420 mA 2 V/5 V/10 V 5 mA/20 mA/420 mA 199,9 19,99 k 5105 0,3/1,5/3/30 k 199,99 199,99 k 5105 0,1/1/10/100 k

2,5 0,510 1,210 0,510 1,210 1,210 0,140

0,15 0,2 0,1 0,2 0,15 0,15 0,1 Tare, Hold, Lock, MF, Min/Max, Peak value, Linearization in 50 points Tare, Hold, Lock, MF, Linear. Min/Max, Peak value, Linearization in 50 points Hold/Lock, Tare, Linearization in 25 points Hold/Lock, Tare, Linearization in 25 points

712 VDC 1030 V AC/DC 1030 V AC/DC 24/110/230 VAC 1030 VDC 1030 V AC/DC 80250 V AC/DC 230 VAC 1224 VDC 24/110/230 VAC 1030 VDC 1030 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC 24/110/230 VAC 1030 VDC Hold/Lock, Linearization in 25 points 1030 V AC/DC 80250 V AC/DC 24/110/230 VAC 1030 VDC 712 VDC 1030 V AC/DC Hold/Lock, Tare, Linearization in 25 points 1030 V AC/DC 24/110/230 VAC 1030 VDC Hold/Lock, Tare, Linearization in 25 points 1030 V AC/DC 80250 V AC/DC 230 VAC 1224 VDC 24/110/230 VAC 1030 VDC Tare, Hold, Lock, MF, Min/Max, Peak value, Mat. operations between inputs, Linearization in 50 points Tare, Hold, Lock, MF, Min/Max, Peak value, Linearization in 50 points Tare, Hold, Lock, Min/Max, Instant/Integrated value, Linearization in 50 points 1030 V AC/DC 80250 V AC/DC

10 12 14 18 20 16

DC VA-meters

OM 45DC OM 47DC OM 402UNI

OM 502DC
*for more see Process monitors

99999

14

1100

0,02

96 x 48

22

OM 36AC OM 352AC

1999 1999

14 14

1,210 0,55

0,3 0,3

96 x 48 96 x 48

12 14

AC VA-meters
*for more see Wattmeters

OM 47AC OMM 37PM OMM 350UNI OM 36PM OM 352UNI

19999 1999 1999 1999 1999 19999 19999 9999

14 9,1 9,1 14 14 14 14 14

1,210 2,5 0,510 1,210 0,510 1,210 1,210 0,140

0,3 0,15 0,2 0,1 0,2 0,15 0,15 0,1

96 x 48 48 x 24 72 x 24 96 x 48 96 x 48 96 x 24 96 x 48 96 x 48

20 8 10 12 14 18 20 16

Process monitors

OM 45PM OM 47PM OM 402UNI

OM 502PM

99999

14

1100

0,02

1030 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC 24/110/230 VAC 1030 VDC

96 x 48

22

OM 502I

999999

14

0,18

0,05

96 x 48

22

Integrators
OM 36OHM OM 352UNI 1999 1999 19999 9999 14 14 14 14

1,210 0,510 1,210 0,140

0,2 0,2 0,2 0,1 Tare, Hold, Lock, MF, Min/Max, Peak value, Linearization in 50 points VRMS, ARMS, W, Hz, Q, S, cos , Hold, Lock, Min/Max 50 points/1 tab., Tare, Hold, Lock, MF, Min/Max, Linearization in 50 points 256 points/16 tab., Tare, Hold, Lock, MF, Min/Max Hold/Lock, Linearization in 25 points

96 x 48 96 x 48 96 x 48 96 x 48

12 14 20 16

1030 V AC/DC 80250 V AC/DC 24/110/230 VAC 1030 VDC 1030 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC 712 VDC 1030 V AC/DC

Ohmmeters

OM 47OHM OM 402UNI

Wattmeters AC VA-meters

OM 402PWR OM 402UNI

9999 9999

14 14

010/120/250/450 V 060/150/300 mV, 1/2,5/5 A 2 V; 5 V, 10 V1 040 V 5 mA; 20 mA; 420 mA 2 V; 5 V, 10 V 5 mA; 20 mA; 420 mA Pt 100 > -20140C Pt 100/500/1000, Ni 1000/10000, Cu 50/100 J/K/T/E/B/S/R/N/L Pt 100, 500, 1000 199,9C, -200850C Pt 100, 500, 1000 199,9C, -200850C Pt 100/500/1000, Ni 1000/10000, Cu 50/100 J/K/T/E/B/S/R/N/L Pt 100/500/1000, Ni 1000/10000, Cu 50/100 J/K/T/E/B/S/R/N/L

0,65 0,240

0,2 0,1

96 x 48 96 x 48

16 16

Linearization instruments

OM 502LX OMM 37RTD OMM 350UNI

99999 1999 1999

14 9,1 9,1

1100 2,5 0,510

0,02 0,8 0,2

96 x 48 48 x 24 72 x 24

22 8 10

Hold, Lock, Aut. compensation CJC

1030 V AC/DC

OM 36RTD

1999 19999 1999

14 14 14

1,210 2,5 0,510

0,2 0,2 0,2 Hold, Lock, Aut. compensation CJC Aut. compensation CJC, Tare, Hold, Lock, MF, Min/Max, Peak value

24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 1030 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC

96 x 48 96 x 48 96 x 48

12 20 14

Thermometers

OM 47RTD OM 352UNI

OM 402UNI

9999

14

0,140

0,15

96 x 48

16

Page
8

Input

Data

Type

RTC

Rate (measurement/s)

AO /Data/Exc.

Power supply

Accuracy (% of range)

Digital lters

Height (mm)

Dimensions (mm)
72 x 24 96 x 48 96 x 48

Projection

Excitation

Functions

OM Link

Analog

Limits

OMM 350UNI OM 352UNI OM 402UNI

1999 1999 9999

9,1 14 14

Lin. potentiometer > 500 Lin. potentiometer > 500 Lin. potentiometer > 500

0,510 0,510 0,140

0,2 0,2 0,2

Hold/Lock, Tare, Linearization in 25 points Hold/Lock, Tare, Linearization in 25 points Tare, Hold, Lock, MF, Min/Max, Linearization in 50 points Tare, Hold, Lock, MF, Linear. Min/Max, Peak value, Linearization in 50 points Tare, Hold, Lock, MF, Min/Max, Peak value, Weighing function, Linearization in 50 points Hold/Lock, Preset, calibration const., time backup Hold/Lock, Preset, Sum calibration and division const. Mat. operations, time backup Hold, Lock, Preset, Sum calibration and division const. Mat. operations, time backup Hold/Lock, Preset, calibration const., time backup Tare, Hold, Lock, MF, Linear. Min/Max, Peak value, Linearization in 50 points 24 tapping leads + signalling

1030 V AC/DC 1030 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC

10 14 16

Page Displays for linear potentiometers


22 22

Input

Data

Type

OM 502DU

99999

14

Lin. potentiometer > 500

1100

0,05

RTC

96 x 48

OM 502T

99999

14

14; 28; 416 mV/V

1100

0,05

96 x 48

Weighing indicators
72 x 24 10

OMM 650UC

999999

9,1

TTL, PNP/NPN, 0,1 Hz 50 kHz, <30/300 V counter/frequency/timer TTL, PNP/NPN, 0,02 Hz100 kHz, < 60 V 2x counter/frequency, IRC, timer/clock, phase, repeat TTL, PNP/NPN, line 0,02 Hz1 MHz, < 60 V (mV) 12 input,timer/clock, counter/frequency,UP/DW, IRC TTL, PNP/NPN, 0,1 Hz 50 kHz, <30/300 V counter/frequency/timer RS 232/RS 485 ASCII/MESSBUS/MODBUS-RTU PROFIBU BCD, transformer tapping leads BCD - serial BIN/BCD - paralel Auxiliary inputs (UP/DW)

0,550 s

0,05

1030 V AC/DC

OM 601UQC

999999

14

0,0550 s
(100/500 s)

0,01

24/110/230 VAC 1030 VDC

96 x 48

24

OM 602UQC

999999

14

0,0550 s
(100/500 s)

0,01

1030 V AC/DC 80250 V AC/DC

96 x 48

26

Counters Frequency meter Timer

OM 652UC

999999

14

0,550 s

0,05

1030 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC 950 V AC/DC 80250 V AC/DC 1030 V AC/DC 80250 V AC/DC

96 x 48

14

OM 602RS

999999

14

96 x 48

28

OM 621BCD

999999

14

96 x 48

30

Data displays

OM 602AV

999999

14

0,2

sinus/saw/triangle/ rectangle/random function Hold, Lock, MF, Min/Max Linearization in 50 points Tare, Hold, Lock, MF, Min/ Max, Peak value, Ex. control, Rounding, Mat. operations between inputs, Aut. compensation CJC Linearization in 50 points

96 x 48

28

Programmable AO

OMU 408UNI

9999

14

4x/8x 60 mV40 V 020/420 mA/02/5/10 V 00,1/1/10/100 k Pt 100/500/1 000, Cu 50/100 Ni1 000/10 000 J/K/T/E/B/S/R/N/L Lin. potentiometer > 500 60 mV500 V/ 05 A 020/420 mA/02/5/10 V 00,1/1/10/100 k Pt 100/500/1 000 Ni1 000/10 000, Cu 50/100 J/K/T/E/B/S/R/N/L Lin. potentiometer > 500 010/120/250/450 V 060/150/300 mV, 1/2,5/5 A

1,040

0,2

1030 V AC/DC 80250 V AC/DC

96 x 48

32

Loggers

OMB 402UNI OMB 412UNI

30 LED + 9999 24 LED + 999

9,1

0,140

0,2

Tare, Hold, Lock, MF, Min/ Max, Peak value, Ex. control, Rounding, Linearization in 50 points

1030 V AC/DC 80250 V AC/DC

96 x 48

34 36

OMB 402PWR OMB 412PWR

30 LED + 9999 24 LED + 999

9,1

0,65

0,2

VRMS, ARMS, W, Hz, Q, S, cos , Hold, Lock

1030 V AC/DC 80250 V AC/DC

96 x 48

34 36

OMB 402UQC OMB 412UQC

30 LED + 999999 24 LED + 999

9,1

TTL, PNP/NPN, line 0,02 Hz1 MHz, < 60 V (mV) 12 input, timer/clock, counter/frequency,UP/DW, IRC 02/5/10 V, 020/420 mA , Pt/Ni 1000, Lin. pot, 0100 k 02/5/10 V, 020/420 mA , Pt/Ni 1000, Lin. pot, 0100 k 02/5/10 V, 020/420 mA , Pt/Ni 1000, Lin. pot, 0100 k

0,0550 s
(100/500 s)

0,01

Hold, Lock, Preset, Sum Calibration and division const. Mat. operations, time backup

1030 V AC/DC 80250 V AC/DC

96 x 48

34 36

Bargraphs

OMB 200 OMB 300 OMB 500

20 LED 30 LED (2x) 50 LED

0,510 0,510 0,510

0,5 segm. 0,5 segm. 0,5 segm.

Hold/Lock Linearization in 25 points Hold/Lock Linearization in 25 points Hold/Lock Linearization in 25 points

1030 V AC/DC 1030 V AC/DC 1030 V AC/DC

72 x 24 96 x 24 144x48

38 38 38

on request

standard

cannot be ordered

Rate (measurement/s)

Power supply

Accuracy (% of range)

Digital lters

Height (mm)

AO or Data

Dimensions (mm)
113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 113x 98 96 x 48

Projection

Excitation

Functions

OM Link

Analog

Limits

OMD 201UNI

999999

57 125

Large displays
OMD 201PWR OMD 201UQC 999999 999999 57 125 57 125 57 125

60 mV500 V 0,1 A5 A 14 inputs 2 V/5 V/10 V/040 V 5 mA/20 mA/420 mA 0,1/1/10/100 k Pt 100/500/1 000 Ni1 000/10 000, Cu 50/100 J/K/T/E/B/S/R/N/L Lin. potentiometer > 500 05 A/0450 V TTL, PNP/NPN < 100 kHz 2x counter/frequency, IRC, timer/clock, phase, repeat RS 232/RS 485 ASCII/MESSBUS/MODBUS/ PROFIBUS 60 mV450 V 5 mA5 A 02 V, 05, 010 V 020, 420 mA 60 mV450 V 5 mA5 A 05 A/0450 V Pt 100/500/1000, Ni 1000 -50850C 0,5100 k 0,1100 k

1,340

0,15

Tare, Hold, Lock, MF, Min/Max, Peak value, Mat. operations between inputs, Linearization in 50 points

1030 V AC/DC 80250 V AC/DC

40

0,55 0,0550 s

0,2 0,01

VRMS, ARMS, W, Hz, Q, S, cos , Hold, Lock Hold, Lock, Preset, Sum calibration and division const. Mat. operations Hold/Lock

1030 V AC/DC 80250 V AC/DC 24/110/230 VAC 1030 VDC 1030 V AC/DC 80250 V AC/DC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC

40 40

OMD 201RS

999999

40

OMX 38DC OMX 38PM OMX 38AC

continuous continuous continuous continuous continuous continuous continuous 0,580 0,580 0,510 0,580 0,580 0,580 0,580 0,150 s

0,1 0,1 0,5 0,5 0,2 0,1 0,2 0,2 0,2 0,3 0,2 0,3 0,3 0,2 0,1 Hold/Lock, Linearization in 25 points Hold/Lock, Linearization in 25 points Hold/Lock Hold/Lock Hold/Lock Hold/Lock, Linearization in 25 points Hold/Lock, Linearization in 25 points Hold/Lock

42 42 42 42 42 42 42 44 44 44 44 44 44 44 44 46 48 50 52

Analog transmitters to DIN rail

OMX 38W OMX 38RTD OMX 38DU OMX 38OHM OMX 100DC OMX 100PM OMX 100PWR OMX 100RTD OMX 100T/C OMX 100DU OMX 100OHM OMX 100F 3+3 LCD 3+3 LCD 3+3 LCD 3+3 LCD 3+3 LCD 3+3 LCD 3+3 LCD 3+3 LCD 5 5 5 5 5 5 5 5

0,4/4/40/400 V, 1/5 A 4/40 mA, 60/300 mV 02/5/10 V 020/420 mA 05 A/0450 V Pt 100/500/1000, Ni 1k/10k -50450C B; R/S/T; E/J/K/N/L Lin. potentiometer > 500 00,999/9,99/99,9 k 5105 TTL, PNP/NPN, 0,1 Hz50 kHz, < 30/150/300 V PROFIBUS DP

24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 24/110/230 VAC 1030 VDC 1030 V AC/DC 80250 V AC/DC

Digital transmitters to DIN rail

Transmitter PROFIBUS Stabilized sources to DIN rail Measuring sites switches

OMX Probus OMP 38 OMP 100 OMA 10S

0,2 0,2 4x 10 positions max. 30 VDC/100 mA

Output 12/15/24 VDC Output 5/12/24 VDC, 96 W Manual - by revolving switch

80250 V AC/DC 230 VAC

on request

standard

cannot be ordered

Page

Input

Data

Type

RTC

OM LINK
The program OM Link is designed for easy configuration, operation, firmware upgrade of instruments and converters and for visualization of the measuring process. The new ORBIT MERRET instruments include the OM Link interface in their standard features. To connect to PC an OML cable is required (version USB or RS232). The program may be used for configuration (1 instrument) or data collection via RS 232 and RS 485 line, more suitable for on-line connection during operation.
OM LINK

Connection manager Main menu: Program > Connection manager Create new connection Main menu: Connection > New...

Measurement manager Main menu: Program > Measurement manager

Open new measurement window Main menu: Measurement > New window

Window Measurement Connection manager Open stored measurement le Main menu: Measurement > Open

Create new connection Main menu: Connection > New...

Load/save conguration of windows, connection & measurement Main menu: Program > Load conguration Program > Save conguration Change active connection parameters Main menu: Connection > Change... Setting application Main menu: Program > Setting... End connection Main menu: Connection > End Events record Main menu: Program > Record End all connections Main menu: Connection > End connection Information about application Main menu: Help > About the program... Display measurement Main menu: Measurement > New window/open

Connection conguration

Connection manager Connection manager facilitates creating and cancelling connections, provides their list classified as per type, noting the basic parameters and measureable values (channels), and serves as home location for starting measurements, configuring the OM instruments, projec ting their properties etc. Connection is the key entity of the OM link application - it represents physical or virtual connection with an OM device and is the basic subject of many application functions. Connection modes: On-line, represents a physical connection to an OM device. Off-line, serves for projection of instrument menu and its configuration for later use in the on-line mode. Calculated, represents a mathematical operation with measured data acquired from other connections (on-line) Line tapping, serves to analyse communication in progress among autonomous mesuring systems

Window Measurement

Load data from instrument Main menu: Instrument > Load data...

Clear memory contents Main menu: Instrument > Reset memory

Instrument setting Main menu: Instrument > Setting

Table of linearization Main menu: Instrument > Table of linearization

Instrument properties and service Main menu: Instrument > Properties...

Script start Main menu: Instrument > Start script...

Upload rmware into instrument Main menu: Instrument > Firmware upload...

Measurement manager Measurement manager facilitates creating and cancelling measurement files, graphs and individual data, provides their structured overview and enables modification of graph and value parameters.

Device setup One of the main features of the OM Link program is the opportunity to set up the instruments comfortably from your computer. Setting the device values and parameters View of the complete setting menu (PROFI/LIGHT/USER) Individual configuration of the complete menu Device setup export and import All existing items may be set, even those that are inaccessible or blocked in the instrument. In majority of the items on the instrument menu their attribute may be set for the User menu (see/ change/hide) and in addition it is possible to remove or add any item from the LIGHT menu. Client menu of the instrument may be compiled eventually this way for given application and level of service proficiency. Each setting of the device menu may be stored in a file and used for configuration of other instruments. An advantage is also the possibility of sending complete menu via e-mail directly to the technical support of the manufacturer.

Window Measurement

Open new measurement window Main menu: Measurement > New window

Open stored measurement le Main menu: Measurement > Open

Save measurement le Main menu: Measurement > Save/Save as...

Close measurement window Main menu: Measurement > Close

Export measurement le to CSV Main menu: Measurement > Export le...

Save photo of graphs to BMP Main menu: Measurement > Save photo...

Window Measurement Window Measurement provides view of historic and current process of measuring certain quantities and their groups. The window offers three possible modes of viewing the measured data: 1) graphs - they reflect the historic course of measurement in selectable time range. By means of the control panel in this mode it is possile to shift the displayed time period, modify the displayed time range (from 1 sec up to 15 days) and set additional parameters of graph projection , (names, date on time axis). 2) Indicators they show current values of the measured data. 3) Table depicts the history of the measuring process in table numeric format. By means of the control panel in this mode it is possible to switch between the projection of interpolated values in particular time steps and the projection of truly taken sample values. The graph and table modes also enable to discontinue the measurement in process and restart it again. At the same time it is also possible to specify whether upon restarting the process the measurement retains its former course (history) and the measurement is reassumed or whether it starts anew and the history is cancelled. Values from the instrument may be added to the measurement e.g. from the Connection manager by selecting certain instrument channel from the on-line connection (or calculated connection or line tapping connection) and dragging it over to the Window Measurement. This way new values (quantities) may also be incorporated in already existing graphs (in case of graph mode), i.e. two quantities in one graph with common standard and time axis. Structuring the quantities and graphs and changing their parameters (names, ranges, colors) may also be performed in Measurement Manager.
ORBIT MERRET 2008.1 en

In Properties and Service you will find complete information about the instrument

OMM 37
3 digit projection Size of DIN 48 x 24 mm Power supply 712 VDC
Options
Power supply 1030 VDC, isolated

OMM 37DC OMM 37PM OMM 37RTD

VOLTMETER AND AMMETER PROCESS MONITOR THERMOMETER FOR Pt 100

Description The OMM 37 model series are small 3 digit panel instruments with good accuracy and stability. For their small dimensions the instruments are suitable for mosaic panels mounting applications. Operation The instrument is designed for simple measurement without further control. Placement of the decimal point is selectable by a shorting link under the front panel. Calibration Contingent corrections of display projection for both limit values of input signal may be performed by trimmers from the back of the instrument ( 10%). Options Isolated power supply with the range of 10...30 VDC is designed for applications, where it is necessary to use galvanic separation from the input signal.

Technical data
PROJECTION Display: 1999, red or green 7-segment LED, digit height 9,1 mm Decimal point: adjustable - by jumper Brightness: adjustable - by trimmer under front panel INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,1 % of range + 1 digit 0,8 % of range + 1 digit (RTD) Rate: 2,5 meas./s Resolution: 1C (RTD) Overload capacity: 10x (t < 30 ms); 2x Calibration: at 25C and 40 % r.h. POWER SUPPLY 712 V AC/DC, max. 100 mA 1030 VDC/ 24VAC, max. 160 mA, isolated MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 48 x 24 x 72 mm Panel cutout: 43,5 x 22,5 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP42 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. Power supply, input > 300 V (PI), 250 V (DI)

PI - Primary insulation, DI - Double insulation

Measuring ranges
DC w/o A B C D E F J K L M Z 199,9 mV 1,999 V 19,99 V 199,9 V PM 05 mA 020 mA 420 mA 2 V 5 V 10 V RTD Pt 100 (-20140C)

199,9 uA 1,999 mA 19,99 mA 199,9 mA on request on request

Connection

Order code

OMM 37
Type R Power supply D P T C M D

712 V, non-isolated 1030 V, isolated Measuring range, see table Measuring ranges

1 2 ? 1 2

Display color

red green

OMM 37DC, PM

Please, state the requested projection for selected input range in your order (PM)! (e.g.: input 020 mA > projection 0.0100.0)

POWER

ES+

ES-

INPUT
2 3

OMM 37RTD

POWER

ORBIT MERRET 2008.1 en

10

OMM 350/650
6 digit programmable projection Digital filters, Linearization Size of DIN 72 x 24 mm Power supply 1030 VDC
Options
Comparators Power supply: 80250 V AC/DC

OMM 350DC OMM 350UNI

DC VOLTMETER AND AMMETER DC VOLTMETER AND AMMETER PROCESS MONITOR OHMMETER THERMOMETER FOR Pt, Cu THERMOMETER FOR Ni THERMOMETER FOR THERMOCOUPLES DISPLAY UNIT FOR LINEAR POTENTIOMETERS UNIVERSAL COUNTER

Options Comparators are assigned to monitor two limit values with relay output. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. In OMM 650UC the comparator setting is extended with the resetting function on a set value and the relay switch-on/switch-off function when the stopwatch/timer is running. Standard functions PROGRAMMABLE PROJECTION Setting: manual, optional display projection may be set in the menu for both limit values of input signal, e.g. input 019,99 V 0150,0 Setting (UC): measuring mode counter/frequency/timer/clock with adjustable calibration coefficient, time base and projection Projection: -99999999999 COMPENSATION of conduct (RTD): automatic (3- and 4-wire) or manual in menu (2-wire) of conduct in probe (RTD): internal connection (conduct resistance in measuring head) of CJC (T/C): manual or automatic, in menu it is possible to perform selection of the type of thermocouple and compensation of cold junctions, which is adjustable or automatic (temperature at the input brackets) LINEARIZATION Linearization: through linear interpolation in 25 points (solely via OM Link) DIGITAL FILTERS Exponential average: from 2100 measurements Rounding: setting the projection step for display Filtration constant (UC): transmits input signal up to 51 000 Hz FUNCTIONS (UC)

OMM 650UC
Description

The OMM 350 model series are small 6 digit panel programmable instruments designed for maximum usefulness and user comfort while maintaining its fair price. There are two versions available: UNI and DC. The OMM 350UNI type is a multifunction instrument with the option of configuration for 8 different input options, easily configurable in the instrument menu. Version OMM 350DC is suitable for measurement of larger ranges of DC voltage and current. The instrument is based on an 8-bit microcontroller with A/D converter , which ensures good accuracy, stability and easy operation of the instrument. The OMM 650UC type is a universal low-cost counter/frequencymeter/ stopwatch.

Operation The instrument is set and controlled by four control keys located on the front panel. All programmable settings of the instrument may be performed in three adjusting modes : Light menu is protected by optional number code and contains solely items necessary for instrument setting Profi menu is protected by optional number code and contains complete instrument setting User menu may contain arbitrary items from the programming menu (LIGHT/PROFI), which determine the right (see, change). Access w/o password. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). All settings are stored in the EEPROM memory (they hold even after the instrument is switched off).

Preset: initial non-zero value, which is always read after resetting the instrument to zero Setting current value: initial value, e.g. the amount currently passed-through EXTERNAL CONTROL

Hold: display/instrument blocking Lock: control keys blocking Resetting: counter resetting Start/Stop: stopwatch/timer control

E W

11

Technical data
PROJECTION Display: -99999999999, red or green 7-segment LED, digit height 9,1 mm Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 100 ppm/C, 50 ppm/C (UC) Accuracy: 0,2 % of range + 1 digit 0,3 % of range + 1 digit (T/C) Accuracy applies for projection 1999 0,05 % of value + 1 digit (UC) 0,01 % of value 2 ms (UC - stopwatch) 0,01 % of value 130 ms (UC - RTC) Accuracy of cold junction measurement: 1C Rate: 0,510 meas./s Overload capacity: 10x (t < 30 ms) - not for 200 V and 5A; 2x Resolution: 0,1C (RTD), 1C (T/C) Watch-dog: reset after 500 ms Functions: HOLD, LOCK, Digital filters Functions (UC): Data backup, Time backup, Preset Input filters (UC): Filtration constant, Rounding Time base (UC): 0,5/1/5/10/50 s Calibration constant (UC): 0,00001999999 Filtration constant (UC): 0/5/40/100/1 000 Hz PRESET (UC): 0999999 OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATORS Type: digital, adjustable in programming mode, contact switch-on < 50 ms Limit: -99999999999 Hysteresis: 999999 Delay: 099,9 s Output: 2x bistable relays (48 VAC/30 VDC, 3 A) POWER SUPPLY 1030 VDC/24 VAC, max. 4 VA, isolated 80250 V AC/DC, max. 4 VA, isolated - in preparation MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 72 x 24 x 106 mm Panel cutout: 68 x 22,5 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP42 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. Power supply, input > 300 V (PI), 250 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 Seismic capacity: IEC 980: 1993, par. 6
PI - Primary insulation, DI - Double insulation

Measuring ranges
OMM 350 type UNI DC: PM: OHM: RTD: Cu: Ni: T/C: DU: type DC DC - Hi: type UC UC: is a multifunction instrument available in following types and ranges 20/60/1 000 mV 020 mA/420 mA/02 V/05 V/010 V 0300 /01,5 k/03 k/030 k Pt 50/100/500/1 000 Cu 50/Cu 100 Ni 1 000/10 000 J/K/T/E/B/S/R/N/L Linear potentiometer (min. 500 ) Connecting individual inputs
DC PM T/C DC - Hi INPUT 1 01 V 0 5/10 V INPUT 2 INPUT 3 060 mV J, K, E, N, L 100/200 V 20/40 V INPUT 4 020 mV 0 2 V B, S, R, T INPUT 5 020 mA, 4 20 mA

1/5 A

Order code specification


UNI w/o A B C D Z --Pt 100/0300 Ohm Pt 500/01500 Ohm Pt 1 000/Ni 1 000/03 kOhm Ni 10 000/030 kOhm on request UC counter/frequency/stopwatch/timer

1 A/5 A/20 V/40 V/100 V/200 V

030 V/0300 V, comparation levels are adjustable in the menu input frequency 0,02 Hz50 kHz

Connection

Order code

OMM 350/650
CJC 1 2 3 4 5
6 7 8 9 10 11 12 13

N
Hold/Lock

+ - + + + +
INPUT INPUT INPUT INPUT GND INPUT

DC, PM

RTD, OHM, Ni
E-- SE-- SESS+ E+ ES+ ES+

N I D C Order code shall not include blank spaces! U C Power supply 1030 V AC/DC, isolated 80250 V AC/DC, isolated* Measuring range, see table Measuring ranges Comparators no 1x relay (Form A) 2x relays (Form A) 1x open collector 2x open collector Time backup no yes Display color red green
* Launch for sale has not been set

Type

0 1 ? 0 1 2 3 4 0 1 1 2

+
L POWER SUPPLY

1 2 3 4

L1

L2

GND

+ +
INPUT 2 INPUT 3

T/C

+
OMM 650UC
9 10 11 12 13

DU

INPUT A (< 300 V) Reset (< 300 V) Reset (< 30 V) INPUT A (< 30 V) GND Hold/Lock

+ + -

ORBIT MERRET 2008.1 en

12

OM 36
3 digit projection Size of DIN 96 x 48 mm Power supply 230 VAC
Options
Excitation Analog output Power supply 24/110 VAC, 1030 VDC, 80250 V AC/DC

OM 36DC OM 36AC OM 36PM OM 36OHM OM 36RTD

DC VOLTMETER AND AMMETER AC VOLTMETER AND AMMETER PROCESS MONITOR OHMMETER THERMOMETER FOR Pt /Ni

Description The OM 36 model series are 3 digit panel instruments with good accuracy and stability. Operation The instrument is designed for simple measurement without further control. Placement of the decimal point is selectable by a shorting link under the front panel. Calibration Contingent corrections of display projection for both limit values of input signal may be performed by trimmers under the front panel ( 10%). Options Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 2...24 VDC. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer several types of current or voltage non-isolated outputs. The analog output value corresponds with the input signal.

13

Technical data
PROJECTION Display: 1999, red or green 7-segment LED, digit height 14 mm Decimal point: adjustable - by jumper Brightness: adjustable - by trimmer under front panel INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,1 % of range + 1 digit 0,2 % of range + 1 digit (RTD, OHM) 0,3 % of range + 1 digit (AC) Rate: 1,210 meas./s Overload capacity: 10x (t < 30 ms) - not for 300 V and 5A; 2x Resolution: 0,1/1C (RTD) Calibration: at 25C and 40 % r.h. ANALOG OUTPUT Type: non-isolated, analog output corresponds with the input signal Non-linearity: 0,3 % of range TC: 100 ppm/C Rate: response to change of value < 40 ms Voltage: 02 V, 05 V, 010 V Current: 020 mA, 420 mA (comp. < 500 ) EXCITATION Adjustable: 224 VDC/50 mA, isolated POWER SUPPLY 24; 110; 230 VAC, 50/60 Hz, 10 %, 5 VA 1224 VDC/max. 150 mA (without AO and excitation) 1030 VDC/max. 300 mA, isolated 80250 V AC/DC, isolated Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 110 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP42, IP64 on request (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. AC power supply > 600 V (PI), 300 V (DI) DC power supply, input, output, Exc. > 300 V (PI), 250 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2

PI - Primary insulation, DI - Double insulation

Measuring ranges
DC w/o A B C D E F H J K L M N P Z 199,9 A 1,999 mA 19,99 mA 199,9 mA 1,999 A 5,00 A on request 199,99 mV 1,999 V 19,99 V 199,9 V 300 V AC 0199,9 mV 01,999 V 019,99 V 0199,9 V 0300 V PM 05 mA 020 mA 420 mA 2 V 5 V 10 V OHM 0199,9 01,999 k 019,99 k RTD 199,9C -200850C w/o 1 2 3 4 5 RTD Pt 100 Pt 500 Pt 1 000

5105

01,999 mA 019,99 mA 0199,9 mA 01,999 A 05,00 A on request on request

Connection

Order code

OM 36
Type
Order code shall not include blank spaces!

D A P H T C C M M D 0 1 2 3 4 5 ? 0 1 2 3 4 5 0 1 1 2 3 1 2

O R Power supply
1 2 3 4 5 6 7 8 9 10 11

N POWER SUPPLY E

Excitation

GND

OM 36DC

24 VAC/50 Hz 230 VAC/50 Hz 1224 VDC 110 VAC/50 Hz 1030 VDC, isolated 80250 V AC/DC, isolated Measuring range, see table Measuring ranges Analog output none 02 V 05 V 010 V 020 mA 420 mA Excitation no yes

+
INPUT 1

+
INPUT 2

Analog output

Connection
*only for type RTD

2-wire *3-wire 4-wire red green

Display color
OM 36AC
10 11

OM 36PM

OM 36OHM
S+ ES+ E+

OM 36RTD
S+

INPUT 2

Please, state the requested projection for selected input range in your order (PM, OHM)! (e.g.: input 020 mA > projection 0.0100.0)

ES+

ES-

E-

INPUT 1 GND

S-

S-

S-

INPUT

E-

ES-

E-

ES+

E+

ORBIT MERRET 2008.1 en

14

OM 352/652
3 digit programmable projection (352) 6 digit programmable projection (652) Multifunction device (DC, PM, RTD, T/C, DU) Digital filter, Tare, Linearization Size of DIN 96 x 48 mm Power supply 80250 V AC/DC
Options
Excitation Dual comparator Data output Analog output Power supply 1030 V AC/DC

OM 352UNI

VOLTMETER AND AMMETER PROCESS MONITOR OHMMETER THERMOMETER FOR Pt, Ni, Cu THERMOMETER FOR THERMOCOUPLES DISPLAY UNIT FOR LINEAR POTENTIOMETERS

OM 352AC OM 352DC OM 652UC


Description

AC VOLTMETER AND AMMETER DC VOLTMETER AND AMMETER UNIVERSAL COUNTER

Comparators are assigned to monitor two limit values with relay output. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII/MODBUS/PROFIBUS protocols. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current. The value of analog output corresponds with the displayed data and its type and range are selectable in menu. Time backup (UC) is suitable where time needs to be measured even in case of supply voltage outage (upon power supply outage the instrument does not display) Standard functions PROGRAMMABLE PROJECTION

The OM 352 model series are simple 3 digit panel programmable instruments designed for maximum usefulness and user comfort while maintaining its fair price. Versions UNI, DC and AC are available. Type OM 352UNI is a multifunction instrument with the option of configuration for 8 different input options, easily configurable in the instrument menu. Versions OM 352DC and OM 352AC are suitable for measurement of larger ranges of DC and AC voltages and currents. The instrument is based on an 8-bit microcontroller with A/D converter , which ensures good accuracy, stability and easy operation of the instrument. The OM 652UC type is a universal low-cost counter/frequencymeter/ stopwatch/timer. Operation The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument may be performed in three adjusting modes: Light menu is protected by optional number code and contains solely items necessary for instrument setting Profi menu is protected by optional number code and contains complete instrument setting User menu may contain arbitrary items from the programming menu (LIGHT/PROFI), which determine the right (see, change). Access w/o password. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). The program is also designed for visualization and filing of measured values from more instruments . All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). Options Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 5...24 VDC.

Selection: of input type and measuring range Setting: manual, in menu optional projection on the display may be set for both limit values of the input signal Setting (UC): measuring mode counter/frequency/timer/clock with adjustable calibration coefficient, time base and projection Projection: 1999, resp. -99999999999 COMPENSATION of conduct (RTD): automatic (3- and 4-wire) or manual in menu (2-wire) of conduct in probe (RTD): internal connection (conduct resistance in measuring head) of CJC (T/C): manual or automatic, in menu it is possible to perform selection of the type of thermocouple and compensation of cold junctions, which is adjustable or automatic (temperature at the input brackets) LINEARIZATION Linearization: through linear interpolation in 25 points (solely via OM Link) DIGITAL FILTERS Exponential average: from 2100 measurements Rounding(UC): setting the projection step for display Filtration constant (UC): transmits input signal up to 51 000 Hz FUNCTIONS Preset (UC): initial non-zero value, which is always read after resetting the instrument to zero Setting current value (UC): initial value, e.g. amount passed-through Tare: resetting display upon non-zero input signal EXTERNAL CONTROL Hold: display/instrument blocking Lock: control keys blocking Resetting: counter resetting Start/Stop: stopwatch/timer control

15

Technical data
PROJECTION Display: 1999 resp. 999999, red or green 7-segment LED, digit height 14 mm -9999999, red/green/orange 7-segment. LED, height 20 mm Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 100 ppm/C, 50 ppm/C (UC) Accuracy: 0,2 % of range + 1 digit 0,3 % of range + 1 digit (AC, T/C) Accuracy applies for projection 1999 0,05 % of value + 1 digit (UC) 0,01 % of value 2 ms (UC - stopwatch) 0,01 % of value 130 ms (UC - RTC) Accuracy of cold junction measurement: 1C Rate: 0,510 meas./s Overload capacity: 10x (t < 30 ms) - not for <200 V and 5A; 2x Resolution: 0,1C (RTD), 1C (T/C) Watch-dog: reset after 500 ms Functions: HOLD, LOCK, Digital filters, Tare Functions (UC): Data backup, Time backup, Preset Input filters (UC): Filtration constant, Rounding Time base (UC): 0,5/1/5/10/50 s Calibration constant (UC): 0,00001999999 Filtration constant (UC): 0/5/40/100/1000 Hz PRESET (UC): 0999999 OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in programming mode, contact switch < 50 ms Limits: 1999; -99999999999; ; -9999999 Hysteresis: 01999; 999999; -9999999 Delay: 099,9 s Output: 2x Form A relays (250 VAC/30 VDC, 3 A) On request open collector may be fitted DATA OUTPUT Protocol: ASCII, MODBUS - RTU, PROFIBUS Data format: 8 bit + no parity + 1 stop bit 7 bit + even parity + 1 stop bit (Messbus) Rate: 300230 400 Baud 9 600 Baud12 Mbaud (PROFIBUS) RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 4 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 250 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 ) EXCITATION Adjustable: 524 VDC/max. 1,2 W POWER SUPPLY 1030 V AC/DC, 10%, max. 13,5 VA 80250 V AC/DC, 10%, max. 13,5 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 120 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP65 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 670 V (PI), 300 V (DI) input, output, Exc. > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 Seismic capacity: IEC 980: 1993, par. 6

PI - Primary insulation, DI - Double insulation

Measuring ranges
OM 352 is a multifunction instrument available in following types and ranges type UNI DC: 20/60/1 000 mV PM: 020 mA/420 mA/02 V/05 V/010 V OHM: 0300 /01,5 k/03 k/030 k RTD: Pt 50/100/500/1 000 Cu: Cu 50/Cu 100 Ni: Ni 1 000/10 000 T/C: J/K/T/E/B/S/R/N/L DU: Linear potentiometer (min. 500 ) type DC DC - Hi: typ AC AC: type UC UC: 1 A/5 A/20 V/40 V/100 V/200 V 01 A/05 A 060 mV/0300 mV/024 V/050 V/090 V/0120 V/0250 V/0450 V 030 V/0300 V, comparation levels are adjustable in the menu input frequency 0,02 Hz50 kHz
w/o A B C D Z

Connecting individual inputs


DC PM T/C DC - Hi AC INPUT 1 01 V 0 5/10 V INPUT 2 INPUT 3 060 mV J, K, E, N, L 100/200 V 090/450 V 20/40 V 050/250 V INPUT 4 020 mV 0 2 V B, S, R, T INPUT 5 020 mA, 4 20 mA

024/120 V

060/300 mV

1/5 A 00,5/1/5 A

Order code specification


UNI --Pt 100/0300 Ohm Pt 500/01500 Ohm Pt 1 000/Ni 1 000/03 kOhm Ni 10 000/030 kOhm on request UC counter/frequencymeter/stopwatch/timer

Connection

Order code

OM 352/652
N I D C A C Order code shall not include blank spaces! U C Power supply 1030 V AC/DC 80250 V AC/DC Measuring range, see table Measuring ranges Comparators no 1x relay (Form A) 2x relays (Form A) 1x open collector 2x open collector Output none Excitation Analog output RS 232 RS 485 MODBUS* PROFIBUS Time backup no yes Display color red (14 mm) green (14 mm) red/green/orange (20 mm)
* Launch for sale has not been set

Type

0 1 ? 0 1 2 3 4 0 1 2 3 4 5 6 0 1 1 2 3

5 6

9 10

11 12 13 14 15 16 17 18

CJC

E N POWER SUPPLY
RxD TxD GND Hold/Lock
232

+ - + + + +
INPUT INPUT INPUT INPUT GND INPUT

DC, PM

OM 652UC
11 12 13 14 15 16 17 18

INPUT A (< 300 V) Reset (< 300 V) Reset (< 30 V) INPUT A (< 30 V) GND Hold/Lock

L + + + + + -

L1

L2

1 2 3 4

Rx/Tx+ Rx/TxGND
485

RTD, OHM, Ni
E-- SE-- SESS+ E+ ES+ ES+

- + +
AO - U AO - I GND

GND

+ +
INPUT 2 INPUT 3

T/C

- +
Excitation

DU

ORBIT MERRET 2008.1 en

16

OM 402
4-digit programmable projection Multifunction device (DC, PM, RTD, T/C, DU) Digital filters, Tare, Linearization Size of DIN 96 x 48 mm Power supply 80250 V AC/DC
Options
Excitation Comparators Data output Analog output Data record Power supply: 1030 V AC/DC

OM 402UNI

DC VOLTMETER AND AMMETER PROCESS MONITOR OHMMETER THERMOMETER FOR Pt, Cu THERMOMETER FOR Ni THERMOMETER FOR THERMOCOUPLES DISPLAY UNIT FOR LINEAR POTENTIOMETERS

OM 402PWR
Description

AC NETWORK ANALYSER

with relay output. The user may select limits regime: LIMIT/DOSING/FROM-TO. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII/MESSBUS/MODBUS/PROFIBUS protocol. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current. The value of analog output corresponds with the displayed data and its type and range are selectable in menu. Measured data record is an internal time control of data collection. It is suitable where it is necessary to register measured values. Two modes may be used. FAST is designed for fast storage (40 records/s) of all measured values up to 8 000 records. Second mode is RTC, where data record is governed by Real Time with data storage in a selected time segment and cycle. Up to 130 000 values may be stored in the instrument memory. Data transmis sion into PC via serial interface RS232/485 and OM Link. Standard functions PROGRAMMABLE PROJECTION Selection: of input type and measuring range Measuring range: adjustable as fixed or with automatic change Measuring modes (PWR): voltage (VRMS), current (ARMS), real power (W), frequency (Hz) and with calculation of Q, S, cos Setting: manual, in menu optional projection on the display may be set for both limit values of the input signal Projection: -99999999999 COMPENSATION of conduct (RTD, OHM): automatic (3- and 4-wire) or manual in menu (2-wire) of CJC (T/C): manual or automatic, in menu it is possible to perform selection of the type of thermocouple and compensation of cold junctions, which is adjustable or automatic (temperature at the input brackets) LINEARIZATION Linearization: by linear interpolation in 50 points (solely via OM Link) DIGITAL FILTERS Floating/Exp./Arithmetic average: from 230/100/100 measurements Rounding: setting the projection step for display MATHEMATIC FUNCTIONS Min/max. value: registration of min/max. value reached during measurement Tare: designed to reset display upon non-zero input signal Peak value: the display shows only max. or min. value Mat. operations: polynome, 1/x, logarithm, exponential, power, root, sin x EXTERNAL CONTROL

The OM 402 model series are 4 digit panel programmable instruments designed for maximum efficiency and user comfort while maintaining their favourable price. Two models are available: UNI and PWR. Type OM 402UNI is a multifunction instrument with the option of configuration for 8 various input options, easily configurable in the instrument menu. By further options of input modules it is feasible to measure larger ranges of DC voltage and current or increase the number of inputs up to 4 (applies for PM). The instrument is based on an 8-bit microcontroller with a multichannel 24-bit sigma-delta converter, which secures high accuracy, stability and easy operation of the instrument. Operation The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument may be performed in three adjusting modes: Light menu is protected by optional number code and contains solely items necessary for instrument setting Profi menu is protected by optional number code and contains complete instrument setting User menu may contain arbitrary items from the programming menu (LIGHT/PROFI), which determine the right (see, change). Access w/o password. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). The program is also designed for visualization and filing of measured values from more instruments . All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). The measured units may be projected on the display. Options Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 5...24 VDC. Comparators are assigned to monitor one, two, three or four limit values

Lock control keys blocking Hold display/instrument blocking Tare tare activation Resetting MM resetting min/max value

17

Technical data
PROJECTION Display: -99999999999, red or green 14-segment LED, digit height 14 mm -9999999, red/green/orange 7-segment LED, height 20 mm Description: last two characters on the display may be used for description of measured quantities (adjustable in the menu) Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,1 % of range + 1 digit 0,15 % of range + 1 digit (RTD, T/C) 0,3 % of range + 1 digit (PWR) The accur. applies for project. 9999 and rate 5 (2,5) meas./s (PWR) Accuracy of cold junction measurement: 1C Rate: 1,340 meas./s, 0,55 meas./s (PWR) Overload capacity: 10x (t < 30 ms) - not for > 250 V, 5 A; 2x Measuring modes (PWR): voltage (VRMS), current (ARMS), real power (W), frequency (Hz) and with calculation of Q, S, cos Linearization: by linear interpolation in 50 points Digital filters: Exp./Floating/Arithmetic average, Rounding Functions: Offset, Min/max value, Tare, Peak value, Mat. operations Ext. control: HOLD, LOCK, Tare Data record: measured data record into instrument memory RTC - 15 ppm/C, time-date-display value, < 130k data FAST - display value, < 8k data Resolution: 1/0,1/0,01C Watch-dog: reset after 0,4 s OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 30 ms Limits: -99999999999 Hysteresis: 0999999 Delay: 099,9 s Output: 2x relays Form A (250 VAC/30 VDC, 3 A) and 2x Form C relays (250 VAC/50 VDC, 3 A), 2x/4x open collectors, 2x SSR, 2x bistable relays DATA OUTPUT Protocol: ASCII, MESSBUS, MODBUS - RTU, PROFIBUS Data format: 8 bit + no parity + 1 stop bit 7 bit + even parity + 1 stop bit (Messbus) Rate: 600115 200 Baud 9 600 Baud12 Mbaud (PROFIBUS) RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 10 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 150 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 /12 V or 1 000 /24 V) EXCITATION Adjustable: 524 VDC/max. 1,2 W POWER SUPPLY 1030 V AC/DC, 10%, max. 13,5 VA 80250 V AC/DC, 10%, max. 13,5 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 120 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP65 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 670 V (PI), 300 V (DI) input, output, Exc. > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 Seismic capacity: IEC 980: 1993, par. 6
PI - Primary insulation, DI - Double insulation

Measuring ranges
OM 402 is a multifunction instrument available in following types and ranges type UNI, standard (code 0) DC: 60/150/300/1 200 mV PM: 05 mA/020 mA/420 mA/2 V/5 V/10 V/40 V OHM: 0100 /01 k/010 k/0100 k RTD: Pt 100/Pt 500/Pt 1 000 Cu: Cu 50/Cu 100 Ni: Ni 1 000/Ni 10 000 T/C: J/K/T/E/B/S/R/N/L DU: Linear potentiometer (min. 500 ) type UNI, option A DC: 0,1/0,25/0,5/2/5 A/100 V/25 V/500 V type UNI, option B (expansion about three inputs) PM: 3x 05 mA/020 mA/420 mA/2 V/5 V/10 V/40 V type PWR input U: input I: 010 V/0120 V/0250 V/0450 V 060 mV/0150 mV/0300 mV/01 A/02,5 A/05 A Order code specification
w/o A B K P S U Z 010/120 V 0250/450 V on request UNI 0 = Standard 0,1/0,25/0,5/2/5 A 100/250/500 V expansion about three inputs (PM) 060/150/300 mV 01/2,5/5 A PWR PWR

on request

on request

Connection
C3 C4 E3 E4 Open collectors Option B SSR INPUT - 4/U INPUT - 4/I INPUT - 3/U INPUT - 3/I GND INPUT - 2/U INPUT - 2/I Option A RxD/L+ TxD/LGND GND AO-I AO-U 1 2 3 4 5 5 6 7
IV V VI

Order code

OM 402
Type Power supply
+ + - + + + +
G

U N I P W R 1030 V AC/DC 80250 V AC/DC none 1x relay (Form A) 2x relays (Form A) 3x relays (2x Form A + 1x Form C) 4x relays (2x Form A + 2x Form C) 2x open collector 4x open collector 2x open collector + 2x relays (Form C) 2x relays (Form C) 2x SSR 2x bistable relays 1x relay (Form C) no yes (compensation < 500 /12 V) yes (compensation < 1 000 /24 V) none RS 232 RS 485 MODBUS PROFIBUS no yes no RTC FAST (only for UNI) red (14 mm) green (14 mm) red/green/orange (20 mm) 0 1 ? 0 1 2 3 4 5 6 7 8 9 A B 0 1 2 0 1 2 3 4 0 1 0 1 2 1 2 3

Option, see table Measuring ranges

Comparators

Relays

10

11 12 13

L3

L4
III II I

PWR

INPUT - U

INPUT - U INPUT - U

- GND - U/I0,5 - GND - I5


INPUT - I

GND - U GND - I INPUT - I

14 15 16 17 18 19 20 21 22 23

Analog output
CJC

Data output
E N POWER SUPPLY
Excitation EXT. 1 EXT. 2 EXT. 3

- + +
INPUT - U INPUT - I GND

DC, PM

*GND (Option A) has a galvanic connection with EXT input and OM Link connector
ORBIT MERRET 2008.1 en

L1
E1 C1 E2

L2
C2

RTD, OHM, Ni Open collectors


E+ E+ ES+ S+ SS+ E-ES-ES-

Excitation Data record

T/C

Display color
+
DU

18

OM 45
4 digit projection Size of DIN 96 x 24 mm Power supply 230 VAC
Options
Power supply: 1224 VDC

OM 45DC OM 45PM

DC VOLTMETER AND AMMETER PROCESS MONITOR

Description The OM 45 model series are low 4 digit panel instruments. For their dimensions the instruments are suitable for mosaic panels mounting applications. Operation The instrument is designed for simple measurement without further control. Placement of the decimal point is selectable by jumper under the front panel. Calibration Contingent corrections of display projection for both limit values of input signal may be performed by trimmers from the back of the instrument ( 10%)e

19

Technical data
PROJECTION Display: 19999, red or green 7-segment LED, digit height 14 mm Decimal point: adjustable - by jumper Brightness: adjustable - by trimmer under front panel INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,15 % of range + 1 digit Rate: 1,210 meas./s Overload capacity: 10x (t < 30 ms) - not for 200 V; 2x Calibration: at 25C and 40 % r.h. POWER SUPPLY 230 VAC/50 Hz, 10%, 4 VA 1224 VDC/max. 150 mA, non-isolated Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 24 x 100 mm Panel cutout: 90,5 x 22,5 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP40 (front panel only) El. safety: EN 61010-1, A2
PI - Primary insulation, DI - Double insulation

Insulation resistance: for pollution degree II, measuring cat. III. AC power supply > 600 V (PI), 300 V (DI) DC power supply, input > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2

Measuring ranges
DC w/o A B C D E F J K L M Z PM 05 mA 020 mA 420 mA 2 V 5 V 10 V

1,9999 V 19,999 V 199,99 V

199,99 A 1,9999 mA 19,999 mA 199,99 mA on request on request

Connection

Order code

OM 45
Type
Power supply D P C M 230 VAC/50 Hz 1224 VDC, non-isolated Measuring range, see table Measuring ranges red green

1 2 ? 1 2

Display color

Please, state the requested projection for selected input range in your order (PM)! (e.g.: input 020 mA > projection 0.00100.00)

N POWER SUPPLY E

GND

+ +
INPUT 1 INPUT 2

ORBIT MERRET 2008.1 en

20

OM 47
4 digit projection Size of DIN 96 x 24 mm Power supply 230 VAC
Options
Excitation Dual comparator Analog output Power supply: 24/110 VAC, 1030 VDC

OM 47DC OM 47AC OM 47PM OM 47OHM OM 47RTD

DC VOLTMETER AND AMMETER AC VOLTMETER AND AMMETER PROCESS MONITOR OHMMETER THERMOMETER FOR Pt XXX

Description The OM 47 model series are 4 digit panel instruments with good accuracy and stability. Operation The instrument is designed for simple measurement without further control. Placement of the decimal point is selectable by jumper under the front panel. Calibration Contingent corrections of display projection for both limit values of input signal may be performed by trimmers from the back of the instrument ( 10%) Options Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 2...24 VDC. Dual comparator serves to monitor two limit values with relay output. Limits have adjustable hysteresis. Reaching the preset limits (top over/bottom under) is signalled by LED and simultaneously by the switch-on of the relevant relay. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer several types of current or voltage non-isolated outputs. The analog output value corresponds with the input signal.

21

Technical data
PROJECTION Display: 19999, red or green 7-segment LED, digit height 14 mm Decimal point: adjustable - by jumper Brightness: adjustable - by trimmer under front panel INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,15 % of range + 1 digit 0,2 % of range + 1 digit (RTD) Rate: 1,210 meas./s Overload capacity: 10x (t < 30 ms) - not for 300 V a 5 A; 2x Calibration: at 25C and 40 % r.h. COMPARATOR Type: analog, adjustable by trimmer under front panel Limits: 19999 Hysteresis: < 2 % of range, adj. by trimmer under front panel Output: 2x relays Form A (250 VAC/30 VDC, 3 A) ANALOG OUTPUT Type: non-isolated, AO corresponds with the input signal Non-linearity: 0,3 % of range Rate: response to change of value < 40 ms TC: 100 ppm/C Ranges: 02 V, 05 V, 010 V, 0/420 mA (comp.< 500 ) EXCITATION Adjustable: 224 VDC/50 mA, isolated PM
PI - Primary insulation, DI - Double insulation

POWER SUPPLY 24, 110, 230 VAC, 50/60 Hz, 10%, 5 VA 1030 VDC/max. 300 mA, isolated 80250 V AC/DC isolated MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 110 mm Panel cutout: 92 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP40, on request IP64 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. AC power supply > 600 V (PI), 300 V (DI) DC power supply, input, output, Exc. > 300 V (PI), 250 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2

Measuring ranges
DC w/o A B C D E F H J K L M N P Z 199,99 A 1,9999 mA 19,999 mA 199,99 mA 1,9999 A 5,000 A on request 199,99 mV 1,9999 V 19,999 V 199,99 V 300,0 V AC 0199,99 mV 01,9999 V 019,999 V 0199,99 V 0300,0 V PM 05 mA 020 mA 420 mA 2 V 5 V 10 V OHM 0199,99 01,9999 k 019,999 k 0199,99 k RTD 199,9C -200850C w/o 1 2 3 RTD Pt 100 Pt 500 Pt 1 000

5105

0199,99 mA 01,9999 A 05,000 A on request on request

Connection

Order code

OM 47
Type
D A P H T C C M M D

Order code shall not include blank spaces!

O R

Power supply
1 2 3 4 5 6 7 8 9 10 11 12 13 14

N POWER SUPPLY E

Excitation

OM 47PM

24 VAC/50 Hz 230 VAC/50 Hz 110 VAC/50 Hz 1030 VDC, isolated 80250 V AC/DC, isolated Measuring range, see table Measuring ranges Comparators no yes

0 1 3 4 5 ? 0 1 0 1 2 3 4 5 0 1 1 2 3 1 2

+ +
Excitation

Analog output

INPUT

Analog output

Excitation Connection
*only for type RTD

none 02 V 05 V 010 V 020 mA 420 mA no yes 2-wire *3-wire 4-wire red green

High

Low

Display color
OM 47DC
13 14

OM 47AC
INPUT 2

OM 47OHM
S+ ES+ E+

OM 47RTD
S+ ES+ ES+ E+

ES-

E-

11 12

INPUT 1
GND

INPUT 1 GND

S-

S-

S-

E-

ES-

E-

INPUT 2

Please, state the requested projection for selected input range in your order (PM, OHM)! (e.g.: input 020 mA > projection 0.00100.00)

ORBIT MERRET 2008.1 en

22

OM 502
5-digit programmable projection Math functions, Digital filter, Tare Size of DIN 96 x 48 mm Power supply 80250 V AC/DC
Options
Excitation Comparators Data output Analog output Data record Power supply: 1030 V AC/DC

OM 502DC OM 502PM OM 502I OM 502LX OM 502DU OM 502T

DC VOLTMETER AND AMMETER PROCESS MONITOR INTEGRATOR LINEARIZER DISPLAY UNIT FOR LINEAR POTENTIOMETERS WEIGHING INDICATOR

Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII/MESSBUS/MODBUS/PROFIBUS protocol. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current. The value of analog output corresponds with the displayed data and its type and range are selectable in menu. Measured data record is an internal time control of data collection. It is suitable where it is necessary to register measured values. Two modes may be used. FAST is designed for fast storage (80 records/s) of all measured values up to 8 000 records. Second mode is RTC, where data record is governed by Real Time with data storage in a selected time segment and cycle. Up to 130 000 values may be stored in the instrument memory. Data transmis sion into PC via serial interface RS232/485 and OM Link. Standard functions

Description The OM 502 model series are 5 digit panel programmable instruments. The instrument is based on an 8-bit microcontroller with a multichannel 24-bit sigma-delta converter, which secures high accuracy, stability and easy operation of the instrument. Operation The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument may be performed in three adjusting modes: Light menu is protected by optional number code and contains solely items necessary for instrument setting Profi menu is protected by optional number code and contains complete instrument setting User menu may contain arbitrary items from the programming menu (LIGHT/PROFI), which determine the right (see, change). Access w/o password. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). The program is also designed for visualization and filing of measured values from more instruments . All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). The measured units may be projected on the display. O p t i o n s Options Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 2...24 VDC. Comparators are assigned to monitor one, two, three or four limit values with relay output. The user may select limits regime: LIMIT/DOSING/FROMTO. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay.

PROGRAMMABLE PROJECTION Setting: manual, in menu optional projection on the display may be set for both limit values of the input signal, e.g. input 0300,0 V 0450,0 Projection: -99999999999 Weighing function (T): manual or automatic calibration, signalization of stabilized equilibrium, zero stabilization, automatic zero monitoring, defined number of segments on the scale Projection (T): 99999 (Mode - Standard) Selection of segment size (T): 0,001/0,002/0,005/0,01/0,02/0,05/0,1/0,2/0,5/1 /2/5/10/20/50/100 (Mod - VAHA) LINEARIZATION Linearization: by linear interpolation in 50 points (solely via OM Link) Linearization (LX): by linear interpolation in 256 points and 16 tables DIGITAL FILTERS Floating/Exp./Arithmetic average: from 230/100/100 measurements Rounding: setting the projection step for display MATHEMATIC FUNCTIONS Min/max. value: registration of min/max. value reached during measurement Tare: designed to reset display upon non-zero input signal Fixed tare (T): firmly preset tare Peak value: the display shows only max. or min. value Mat. operations: polynome, 1/x, logarithm, exponential, power, root, sin x EXTERNAL CONTROL Lock control keys blocking Hold display/instrument blocking Tare tare activation Resetting MM resetting min/max value

23

Technical data
PROJECTION Display: -99999999999, red or green 14-segment LED, digit height 14 mm Description: last two characters on the display may be used to describe measured quantities (adjustable in menu) Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,05 % of range + 1 digit 0,1 % of range + 1 digit DU, T Accuracy applies for projection 99999 and rate of 10 meas/s Rate: 0,1100 meas./s; 0,18 meas./s (I), Overload capacity: 10x (t < 30 ms) - not for > 300 V,5 A; 2x Time base (I): 1 s (for integration) Linearization: by linear interpolation in 50 points Linearization (LX): by linear interpolation in 256 points/16 tab. Digital filters: Exp./Floating/Arithmetic average, Rounding Functions: Offset, Min/max value, Tare, Peak value, Mat. operations Ext. control: HOLD, LOCK, Reset Min/Max, Tare Data record: measured data record into instrument memory RTC - 15 ppm/C, time-date-display value, < 130k data FAST - display value, < 8k data Watch-dog: reset after 0,4 s OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 30 ms Limits: -99999999999 Hysteresis: 0999999 Delay: 099,9 s Output: 2x relays Form A (250 VAC/30 VDC, 3 A) and 2x Form C relays (250 VAC/50 VDC, 3 A), 2x/4x open collectors, 2x SSR, 2x bistable relays DATA OUTPUT Protocol: ASCII, MESSBUS, MODBUS - RTU, PROFIBUS Data format: 8 bit + no parity + 1 stop bit 7 bit + even parity + 1 stop bit (Messbus) Rate: 600115 200 Baud 9 600 Baud12 Mbaud (PROFIBUS) RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 10 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 150 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 /12 V or 1 000 /24 V) EXCITATION Adjustable: 524 VDC/max. 1,2 W, isolated Fixed: 10 VDC, max. load 80 POWER SUPPLY 1030 V AC/DC, 10%, max. 13,5 VA 80250 V AC/DC, 10%, max. 13,5 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 120 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP65 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 670 V (PI), 300 V (DI) input, output, Exc. > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2

PI - Primary insulation, DI - Double insulation

Measuring ranges
DC w/o A B C D E F K L M N P Z 99,999 mV 999,99 mV 9,9999 V 99,999 V 300,00 V PM 05 mA 020 mA 420 mA 2 V 5 V 10 V I 05 mA 020 mA 420 mA 2 V 5 V 10 V LX 05 mA 020 mA 420 mA 2 V 5 V 10 V DU potentiometer > 500 T 14 mV/V 28 mV/V 416 mV/V

999,99 A 9,9999 mA 99,999 mA 999,99 mA 5,0000 A on request on request on request on request

Connection
C3 C4 E3 E4 Open collector SSR

Order code

OM 502
C M I L X D U Order code shall not include blank spaces! T Power supply 1030 V AC/DC 80250 V AC/DC Measuring range, see table Measuring ranges Comparators none 1x relay (Form A) 2x relays (Form A) 3x relays (2x Form A + 1x Form C) 4x relays (2x Form A + 2x Form C) 2x open collector 4x open collector 2x open collector + 2x relays (Form C) 2x relays (Form C) 2x SSR 2x bistable relays 1x relay (Form C) Data output no RS 232 RS 485 MODBUS PROFIBUS Analog output no yes (compenzation < 500 /12 V) yes (compenzation < 1 000 /24 V) Excitation no yes Data record no RTC FAST Display color red green Type D P

IV V VI

10

11 12 13

G H

5 6

14 15 16 17

E N POWER SUPPLY
EXT. 1 EXT. 2 EXT. 3

A B C

GND AO - I AO - U

L3 L L1
E1 C1

L4

0 1 ? 0 1 2 3 4 5 6 7 8 9 A B 0 1 2 3 4 0 1 2 0 1 0 1 2 1 2
ORBIT MERRET 2008.1 en

OM 502DC, PM, I, LX
RxD/L+ TxD/LGND

+ + -

INPUT U INPUT I GND Shielding

III II I

- GND + Excitation -

L2
Open collector E2 C2

OM 502T
G H

OM 502DU
+
e

A B C

+ + + -

DMS supply Sense INPUT INPUT Sense DMS supply Shielding

Shielding

24

OM 601UQC
6-digit programmable projection Size of DIN 96 x 48 mm Power supply 230 VAC
Options
Excitation Data output Analog output Time backup Power supply: 24/110 VAC, 1030 VDC, 80250 V AC/DC

OM 601UQC

UNIVERSAL COUNTER

Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current. The value of analog output corresponds with the displayed data and its type and range are selectable in CM. Time backup is suitable where time needs to be measured even in case of supply voltage outage (upon power supply outage the instrument does not display) Standard functions PROGRAMMABLE PROJECTION Measuring modes (UQC): counter/frequency meter/dual counter/UP-DW counter/ counter for IRC sensors/repeat measurement/timer/clock Calibration (UQC): calibration coefficient may be set in CM for every channel individually Projection (UQC): -99999999999 with fixed or floating DP in format 10/24/60 Measuring channels (UQC): A and B, two independent functions may be evaluated from one or more measuring inputs Time base (UQC): 0,05/0,5/1/2/5/10/20/50 s Setting (AO): optional projection may be set for both limit values of the AO range in CM DIGITAL FILTERS (UQC) Filtration constant (UC): transmits signal longer than the time set 2,5100 ms Exponen. average: from 2100 measurements n-th value: from 2100 measurements Radius of insensitiveness: band of suppressed change of measured value FUNCTIONS (UQC) Preset (UQC): initial non-zero value, which is always read after resetting the instrument to zero Summation (UQC): registration of the number upon shift operation Pre-division constant (UQC): 1/10/60/100/1000/3600 Min/max. value (UQC): registration of min./max. value reached during measurement Tare (UQC): designed to reset display upon non-zero input signal Rounding (UQC): setting the projection step for display Mat. operations (UQC): polynome, 1/x, log., exponential, power, root, sin x EXTERNAL CONTROL Hold: display/instrument blocking Lock: control keys blocking OUTPUTS Limits: 2 relays with switching contact, the limits have adjustable hysteresis and time delay of the switch-on, which is signalled by LED and switch-on of the relevant relay The UQC type has adjustable regime of limits switching > LIMIT/DOSE/FROM-TO

Description The OM 601UQC model is a universal 6 digit panel programmable impulse counter/frequency meter/repeat/phase evaluation of signal from IRC sensors and timer/clock. The instrument is based on an 8-bit processor that secures high accuracy, stability and easy operation of the instrument. Operation The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument are realised in two adjusting modes. Configuration menu (hereinafter referred to as CM) is protected by an optional number code and contains complete instrument setting. User menu may contain arbitrary programming settings defined in CM with another selective restriction (see, change) Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates. The OM Link program is freely accesible. All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). The measured units may be projected on the display. Options Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 2...24 VDC. Comparators are assigned to monitor one, two, three or four limit values with relay output. The user may select limits regime: LIMIT/DOSING/FROMTO. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII protocol.

25

Technical data
PROJECTION Display: 999999, red or green 14-segment LED, digit height 14 mm Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 50 ppm/C Accuracy: 0,01 % of range + 1 digit Input frequency: 0,02100 kHz (200 kHz for IRC) Measuring mode: 2x UP or DW counter, UP or DW counter + frequency, UP/DW counter, UP/DW counter for IRC + frequency, timer/clock/phase Functions: Data backup, Time backup, Preset Input filters: Filtration constant, Rounding Time base: 0,0550 s Calibration constant: 0,00001999999 Filtration constant: 0/2,5/5/12,5/100 ms PRESET: 0999999 Pre-division constant: 1/10/60/100/1000/3600 Watch-dog: reset after 1,2 s Functions: HOLD, LOCK, Digital filters, Tare Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 30 ms Limits: -99999999999 Hysteresis: 0999999 Delay: 099,9 s Output: 2x Form A relays (250 VAC/30 VDC, 3 A) On request SSR or open collector may be fitted DATA OUTPUT Data format: 8 bit + no parity + 1 stop bit Rate: 600115 200 Baud RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 10 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 150 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 ) EXCITATION Adjustable: 29 V/100 mA - 912 V/65 mA 1524 V/50 mA - with DC power supply maximum consumption is 80 mA POWER SUPPLY 24; 110; 230 VAC, 50/60 Hz, 10 %, 5 VA 1030 VDC/max. 300 mA, isolated 80250 V AC/DC, isolated Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 120 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP65 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. AC power supply > 600 V (PI), 300 V (DI) DC power supply, input, output, Exc. > 300 V (PI), 250 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2

PI - Primary insulation, DI - Double insulation

Measuring ranges

Connection

Order code

OM 601UQC
Power supply 24 VAC/50 Hz 230 VAC/50 Hz 110 VAC/50 Hz 1030 VDC, isolated 80250 V AC/DC, isolated none Analog RS 232 RS 485 no yes no yes red green

0 1 3 4 5 0 1 2 3 0 1 0 1 1 2

Output
7 L2 6

L1 4

Time backup Excitation Display color

10

11 12 13 14

15 16

RxD

GND Hold/Lock

232 GND Rx/TxRx/Tx+

485

+ + +
INPUT C/Reset INPUT B INPUT A

+
E
GND TxD Excitation/Lock GND Analog output

N POWER SUPPLY

ORBIT MERRET 2008.1 en

26

OM 602UQC
6-digit programmable projection 2x counter UP/DOWN, 2x IRC Mat.functions, Digital filter, Tare, Preset, Sum Size of DIN 96 x 48 mm Power supply 80250 V AC/DC
Options
Excitation Comparators Data output Analog output Data record Time backup Power supply: 1030 V AC/DC

OM 602UQC

UNIVERSAL COUNTER

Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII/MESSBUS/MODBUS/PROFIBUS protocol. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current. The value of analog output corresponds with the displayed data and its type and range are selectable in menu. Measured data record is an internal time control of data collection. It is suitable where it is necessary to register measured values. Two modes may be used. FAST is designed for fast storage (80 records/s) of all measured values up to 8 000 records. Second mode is RTC, where data record is governed by Real Time with data storage in a selected time segment and cycle. Up to 130 000 values may be stored in the instrument memory. Data transmis sion into PC via serial interface RS232/485 and OM Link. Time backup is suitable where time needs to be measured even in case of supply voltage outage (upon power supply outage the instrument does not display) Standard functions PROGRAMMABLE PROJECTION Input: NPN, PNP, upon contact, IRC, line Measuring modes: counter/frequency/UP-DW counter + frequency/counter for IRC Calibration: calibration coefficient for each channel may be set in menu independently Projection: -99999999999 with fixed or floating DP in format 10/24/60 Measuring channels: A and B, from one or more measuring inputs two independent functions may be evaluated Time base: 0,05/0,5/1/2/5/10/20/50/100 s LINEARIZATION

Description

OM 602UQC is a universal 6 digit panel programmable dual-channel impulse counter/frequency meter/evaluation of signal from IRC sensors and timer/clock. The instrument is based on an 8-bit processor that secures high accuracy, stability and easy operation of the instrument.

Operation

The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument may be performed in three adjusting modes: Light menu is protected by optional number code and contains solely items necessary for instrument setting Profi menu is protected by optional number code and contains complete instrument setting User menu may contain arbitrary items from the programming menu (LIGHT/PROFI), which determine the right (see, change). Access w/o password. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). The program is also designed for visualization and filing of measured values from more instruments . All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). The measured units may be projected on the display. Options

Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 5...24 VDC. Comparators are assigned to monitor one, two, three or four limit values with relay output. The user may select limits regime: LIMIT/DOSING/FROM-TO. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay.

P R E L

IM

Linearization: by linear interpolation in 50 points (solely via OM Link) FUNCTIONS

Preset: initial non-zero value, which is always read after resetting the instrument to zero Summation: registration of the number upon shift operation Pre-division constant: 1999999 DIGITAL FILTERS

Filtration constant (UC): transmits input signal up to 102 000 Hz Floating/Exp./Arithmetic average: from 230/100/100 measurements Rounding: setting the projection step for display MATHEMATIC FUNCTIONS

Min/max. value: registration of min/max. value reached during measurement Tare: designed to reset display upon non-zero input signal Peak value: the display shows only max. or min. value Mat. operations: polynome, 1/x, logarithm, exponential, power, root, sin x and at the same time between inputs - sum, difference, product, quotient

EXTERNAL CONTROL Lock control keys blocking Hold display/instrument blocking Tare tare activation Resetting MM resetting min/max value Start/Stop: stopwatch/timer control

IN

27

Technical data
PROJECTION Display: -99999999999, red or green 14-segment LED, digit height 14 mm Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 50 ppm/C Accuracy: 0,01 % of range + 1 digit Input frequency: 0,02800 000 Hz (400 kHz - for IRC) Measuring mode: 2x UP or DW counter + frequency, UP/DW counter for IRC + frequency Input filters: Filtration constant, Rounding, Digital filters Time base: 0,0550 s Calibration constant: 0,00001999999 Filtration constant: 0/2,5/5/12,5/100 ms PRESET: 0999999 Pre-division constant: 1/10/60/100/1000/3600 Digital filters: Exp./Floating/Arithmetic average, Rounding Functions: Preset, Sum, Data backup, Min/max value, Tare, Peak value., Mathematic operations Ext. control: HOLD, LOCK, Tare, Resetting to zero Data record: measured data record into instrument memory RTC - 15 ppm/C, time-date-display value, < 130k data FAST - display value, < 8k data Watch-dog: reset after 0,4 s OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 30 ms Limits: -99999999999 Hysteresis: 0999999 Delay: 099,9 s Output: 2x relays Form A (250 VAC/30 VDC, 3 A) and 2x Form C relays (250 VAC/50 VDC, 3 A), 2x/4x open collectors, 2x SSR, 2x bistable relays DATA OUTPUT Protocol: ASCII, MESSBUS, MODBUS - RTU, PROFIBUS Data format: 8 bit + no parity + 1 stop bit 7 bit + even parity + 1 stop bit (Messbus) Rate: 600115 200 Baud 9 600 Baud12 Mbaud (PROFIBUS) RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 10 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 40 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 /12 V or 1 000 /24 V) EXCITATION Adjustable: 524 VDC/max. 1,2 W POWER SUPPLY 1030 V AC/DC, 10%, max. 13,5 VA 80250 V AC/DC, 10%, max. 13,5 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 120 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP65 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 670 V (PI), 300 V (DI) input, output, Exc. > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 Seismic capacity: IEC 980: 1993, par. 6

PI - Primary insulation, DI - Double insulation

Connection

Order code

OM 602UQC*
Power supply Input Comparators
L4 L3
8 9 10 1 2 3 4 5

1030 V AC/DC 80250 V AC/DC 2x standard line none 1x relay (Form A) 2x relays (Form A) 0 1 A C 0 1 2 3 4 5 6 7 8 9 A B 0 1 2 3 4 0 1 2 0 1 0 1 0 1 2 1 2

11 12 13

RxD/L+ TxD/LGND GND AO - I AO - U

5 6

14 15 16 17

+ + + + + + +

INPUT C2/Reset INPUT B2 INPUT A2 INPUT C1/Reset INPUT B1 INPUT A1 GND Excitation

Data output

F G H

Line input
INPUT C INPUT B INPUT A INPUT C INPUT B INPUT A GND Excitation

Analog output

+ + + +

A B C

Time backup Excitation Data record

Display color

3x relays (2x Form A + 1x Form C) 4x relays (2x Form A + 2x Form C) 2x open collector 4x open collector 2x open collector + 2x relays (Form C) 2x relays (Form C) 2x SSR 2x bistable relays 1x relay (Form C) no RS 232 RS 485 MODBUS PROFIBUS no yes (compenzation < 500 /12 V) yes (compenzation < 1 000 /24 V) no yes no yes no RTC FAST red green

IV V VI

A B C

F III II I

G H

N POWER SUPPLY

INP 1 INP 2 INP 3

L1

L2

* Scheduled for distribution 1.Q/2008

ORBIT MERRET 2008.1 en

28

OM 602
6-digit programmable projection Size of DIN 96 x 48 mm Power supply 80250 V AC/DC
Options
Excitation Comparators Data output Analog output Data record Power supply: 1030 V AC/DC

OM 602RS OM 602AV

DATA DISPLAY RS 232/485 PROGRAMMABLE OUTPUT

Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII protocol. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current. The value of analog output corresponds with the displayed data and its type and range are selectable in menu. Measured data record is an internal time control of data collection. It is suitable where it is necessary to register measured values. Two modes may be used. FAST is designed for fast storage (80 records/s) of all measured values up to 8 000 records. Second mode is RTC, where data record is governed by Real Time with data storage in a selected time segment and cycle. Up to 130 000 values may be stored in the instrument memory. Data transmis sion into PC via serial interface RS232/485 and OM Link.

Standard functions Description The OM 602RS model is a 6 digit panel display device for projection of data from serial lines RS 232/485. The OM 602AV is a programmable analog output. The instrument is based on an 8-bit processor that secures high accuracy, stability and easy operation of the instrument. Operation The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument may be performed in three adjusting modes: Light menu is protected by optional number code and contains solely items necessary for instrument setting Profi menu is protected by optional number code and contains complete instrument setting User menu may contain arbitrary items from the programming menu (LIGHT/PROFI), which determine the right (see, change). Access w/o password. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). The program is also designed for visualization and filing of measured values from more instruments . All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). The measured units may be projected on the display. Options Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 2...24 VDC. Comparators are assigned to monitor one, two, three or four limit values with relay output. The user may select limits regime: LIMIT/DOSING/FROM-TO. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. PROGRAMMABLE PROJECTION Input (RS): optional RS 232 or RS 485, with protocole ASCII, MESSBUS, PROFIBUS, MODBUS - RTU Projection: -99999999999 with fixed or floating DP Setting (AO): optional projection may be set for both limit values of the AO range in CM DIGITAL FILTERS Exponen. average: from 2255 measurements Rounding: setting the projection step for display MATHEMATIC FUNCTIONS Min/max. value: registration of min/max. value reached during measurement Mat. operations: polynome, 1/x, logarithm, exponential, power, root, sin x Type of output signal (AV): sinus/saw/triangle/rectangle/random functions (selected by control keys or on inputs 1 and 2) EXTERNAL CONTROL Lock control keys blocking Hold display/instrument blocking Resetting MM resetting min/max value Function: control of optional functions from instrument menu

29

Technical data
PROJECTION Display: -99999999999, red or green 14-segment LED, digit height 14 mm, 9999, red/green 7-segment LED, height 20 mm Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY Input filters: Filtration constant, Rounding Ext. control: HOLD, LOCK, Tare Data record: measured data record into instrument memory RTC - 15 ppm/C, time-date-display value, < 250k data FAST - display value, < 8k data Watch-dog: reset after 1,2 s OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 30 ms Limits: -99999999999 Hysteresis: 0999999 Delay: 099,9 s Output: 2x relays Form A (250 VAC/30 VDC, 3 A) and 2x Form C relays (250 VAC/50 VDC, 3 A), 2x/4x open collectors, 2x SSR, 2x bistable relays DATA OUTPUT Protocol: ASCII, MESSBUS, MODBUS - RTU, PROFIBUS Data format: 8 bit + no parity + 1 stop bit 7 bit + even parity + 1 stop bit (Messbus) Rate: 600115 200 Baud 9 600 Baud12 Mbaud (PROFIBUS) RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 10 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 150 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 /12 V or 1 000 /24 V) EXCITATION Adjustable: 524 VDC/max. 1,2 W POWER SUPPLY 1030 V AC/DC, 10%, max. 13,5 VA 80250 V AC/DC, 10%, max. 13,5 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 120 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP65 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 670 V (PI), 300 V (DI) input, output, Exc. > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2

PI - Primary insulation, DI - Double insulation

Measuring ranges
w/o A B C Z AV Programmable analog output RS ASCII/MESSBUS MODBUS - RTU PROFIBUS on request on request

Connection

Order code

OM 602
L4 L3
8 9 10 1 2 3 4 5

0 1 ? 0 1 2 3 4 5 6 7 8 9 A B 0 1 2 3 4 0 1 2 0 1 0 1 2 1 2 3

11 12 13

RxD/L+ TxD/LGND GND AO-I AO-U

5 6

14 15 16 17 18 19 20

OM 602RS RxD TxD GND L+ LG H


RS 232

RS 485

A B C

+ -

Excitation

E N POWER SUPPLY

R S A V Power supply 1030 V AC/DC 80250 V AC/DC Measuring range, see table Measuring ranges Comparators none 1x relay (Form A) 2x relays (Form A) 3x relays (2x Form A + 1x Form C) 4x relays (2x Form A + 2x Form C) 2x open collector 4x open collector 2x open collector + 2x relays (Form C) 2x relays (Form C) 2x SSR 2x bistable relays 1x relay (Form C) Data output no RS 232 RS 485 MODBUS PROFIBUS Analog output no yes (compenzation < 500 /12 V) yes (compenzation < 1 000 /24 V) Excitation no yes Data record no RTC FAST red (14 mm) Display color green (14 mm) red/green/orange (20 mm)

Type

IV V VI III II I

+
Excitation EXT. 1 EXT. 2 EXT. 3

GND

L1

L2

ORBIT MERRET 2008.1 en

30

OM 621BCD
6-digit programmable projection Input BCD/transformer tapping lead Size of DIN 96 x 48 mm Power supply 80250 V AC/DC
Options
Excitation Comparators Data output Analog output Power supply: 950 V AC/DC

OM 621BCD

MONITOR BCD AND ACTIVE TRANSFORMER TAPPING LEADS

Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current. The value of analog output corresponds with the displayed data and its type and range are selectable in CM. Standard functions PROGRAMMABLE PROJECTION Calibration: the type of BCD/transformer lead input may be set in CM Projection: -99999999999 OUTPUT Relays functions: For the tapping leads display device it is possible to set the regime of relay switching - BCD (10=10000)/BIN (10=01010)

Description The OM 621BCD model is a 6 digit panel monitor of serial or parallel BCD/ BIN signal and monitor of active transformer tapping lead, allowing for projection of transitional status and servomotor running. The instrument is based on an 8-bit processor that secures high accuracy, stability and easy operation of the instrument.

Operation The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument are realised in two adjusting modes. Configuration menu (hereinafter referred to as CM) is protected by an optional number code and contains complete instrument setting. User menu may contain arbitrary programming settings defined in CM with another selective restriction (see, change) All settings are stored in the EEPROM memory (they hold even after the instrument is switched off).

Options Comparators are assigned to monitor one, two, three or four limit values with relay output. The user may select limits regime: LIMIT/DOSING/FROMTO. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 2...24 VDC. Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the DIN MessBus/ASCII protocol.

31

Technical data
INPUT BCD display device Serial BCD: 4 data + 6 strobe; 8 data + 3 strobe; 12 data + 2 strobe; 4 data + 3 position + 1 strobe Paralel BIN/BCD: 20 data/24 data Level: 524 VDC, 1060 VDC Addressing: up to 8 display devices Tapping leads display device Input: 524 VDC, 1060 VDC, 90130 VDC, 190250 VDC Number of tap. leads: 24 + 1 signalling (on request 27) Input resistance: 5,5 k/V Output: relay BIN/BCD, 5 relays(250 VAC/50 VDC, 3 A) PROJECTION Display: 999999, red or green 14-segment LED, digit height 14 mm Brightness: fixed INSTRUMENT ACCURACY TC: 60 ppm/C Watch-dog: reset after 1,2 s Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 15 ms Limits: -99999999999 Hysteresis: 099999 Delay: 099,9 s Output: 2x (3) Form A relays and 2x Form C relays (250 VAC/50 VDC, 3 A) DATA OUTPUT Data format: 7 bit + even parity + 1 stop bit (DIN Messbus) 8 bit + no parity + 1 stop bit (ASCII) Rate: 600230 400 Baud RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 10 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 40 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 ) EXCITATION Adjustable: 224 VDC/50 mA, isolated POWER SUPPLY 950 V AC/DC, 10 %, 13,5 VA 80250 V AC/DC, 10 %, 13,5 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 154 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP65 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 600 V (PI), 300 V (DI) Input, output, Exc. > 300 V (PI), 250 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2

PI - Primary insulation, DI - Double insulation

Connection

Order code

OM 621BCD
Power supply Input
POWER N
B 2 INP 9

950 V AC/DC 80250 V AC/DC 525 VDC 1060 VDC 90130 VDC (110 VDC) 190250 VDC (230 VDC) none 1 relay 2 relays 3 relays 4 relays 0 1 A B C D 0 1 2 3 3 5 0 1 2 3 0 1 1 2

L3

L2

L4

L1

L5

Comparators

L
A 1 INP 8 GND GND

17 18 19

20 21 22 23 24 25 26 27 28 29 30 31 32

10

11 12 13

14 15 16

5 relays BCD/BIN (tapping leads display device) none Analog output RS 232 RS 485 Excitation no yes Display color red green Output

INP 10 RxD/A

INP 11

INP 12

INP 13

INP 14

INP 15

INP 16

INP 17

INP 18

INP 19

INP 20

INP 21

INP 22

INP 23

TxD/B

GND

INP 0

INP 1

INP 2

INP 3

INP 4

INP 5

INP 6

INP 7

Sgn

Adr 0

Adr 1

Adr 2

Excit.

AO

ORBIT MERRET 2008.1 en

32

OMU 408UNI
8-channel logger 4-digit programmable projection Digital filter, Tare, Linearization Size of DIN 96 x 48 mm Power supply 80250 V AC/DC
Options
Comparators Data output Analog output Data record Power supply: 1030 V AC/DC

OMU 408UNI

DC VOLTMETER AND AMMETER PROCESS MONITOR OHMMETER THERMOMETER FOR Pt, Cu THERMOMETER FOR Ni THERMOMETER FOR THERMOCOUPLES DISPLAY UNIT FOR LINEAR POTENTIOMETERS

Description

the regime: LIMIT/FROM-TO. The limits have adjustable hysteresis within full range of the display and selectable delay of the switch-on. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII/MESSBUS/MODBUS/PROFIBUS protocol. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current and the option of assigning it to arbitrary input. The value of analog output corresponds with the displayed data and its type and range are selectable in menu. Measured data record is an internal time control of data collection. It is suitable where it is necessary to register measured values. Two modes may be used. FAST is designed for fast storage (80 records/s) of all measured values up to 8 000 records. Second mode is RTC, where data record is governed by Real Time with data storage in a selected time segment and cycle. Up to 250 000 values may be stored in the instrument memory. Data transmis sion into PC via serial interface RS232/485 and OM Link. Standard functions PROGRAMMABLE PROJECTION Selection: of input type and measuring range Setting: manual, in menu optional projection on the display may be set for both limit values of the input signal Projection: -9999999 SWITCHING OF INPUTS Manual: by control key on the front panel or from the outside (EXT. inputs) Automatic: by a set time interval COMPENSATION of conduct (RTD, OHM): automatic (3- and 4-wire) or manual in menu (2-wire) of conduct in probe (RTD): internal connection (conduct resistance in measuring head) of CJC (T/C): manual or automatic, in menu it is possible to perform selection of the type of thermocouple and compensation of cold junctions, which is adjustable or automatic (temperature at the input brackets) LINEARIZATION

OMU 408UNI is an 8-channel logger designed for maximum efficiency and user comfort while maintaining its favourable price. It is a multifunction instrument with the option of configuration for 8 various input options, easily configurable in the instrument menu. The instrument is based on an 8-bit microcontroller with a multichannel 24-bit sigma-delta converters that secure high accuracy, stability and easy operation of the instrument. Great quality of the instrument, owing to the high rate of sampling on individual channels, is the chance to evaluate all measuring inputs at the same time.

Operation The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument may be performed in three adjusting modes: Light menu is protected by optional number code and contains solely items necessary for instrument setting Profi menu is protected by optional number code and contains complete instrument setting User menu may contain arbitrary items from the programming menu (LIGHT/PROFI), which determine the right (see, change). Access w/o password. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). The program is also designed for visualization and filing of measured values from more instruments . All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). The measured units may be projected on the display. Options

Comparators are assigned to monitor four or eight limit values with relay output. For each input the user may select an arbitrary number of relays with

Linearization: by linear interpolation in 255 points/8 channels (solely via OM Link) DIGITAL FILTERS

Floating/Exp./Arithmetic average: from 230/100/100 measurements Rounding: setting the projection step for display

MATHEMATIC FUNCTIONS

Min/max. value: registration of min/max. value reached during measurement Tare: designed to reset display upon non-zero input signal Peak value: the display shows only max. or min. value Mat. operations: polynome, 1/x, logarithm, exponential, power, root, sin x and at the same time between inputs - sum, difference, product, quotient EXTERNAL CONTROL EXT inputs: switching inputs from superior systems or control Hold, Lock, Tare and resetting Min/max. value

33

Technical data
PROJECTION Measured value: -9999999, red or green 14-segment LED, digit height 14 mm Channel identitication: 9, red or green 7-segment LED, digit height 9,1 mm Measuring units: 99, red or green 7-segment LED, digit height 9,1 mm Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,2 % of range + 1 digit The accuracy applies for projection 9999 and rate 5 meas./s Accuracy of cold junction measurement: 1C Rate: 1,340 meas./s Resolution: 0,1C (RTD), 1C (T/C) Compensation of conduct: max. 40 Linearization: by linear interpolation in 255 points/for 8 Chan. Compensation of CJC: manual 099C or automatic Digital filters: Exp./Floating/Arithmetic average, Rounding Functions: Offset, Min/max value, Tare, Peak value, Mat. operat. Ext. control: HOLD, LOCK, Tare Data record: measured data record into instrument memory RTC - 15 ppm/C, time-date-display value, < 250k data FAST - display value, < 8k data Watch-dog: reset after 0,4 s OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, limit may be assigned to arbitrary input, contact switch < 200 ms Limits: -9999999 Hysteresis: 09999 Delay: 099,9 s Outputs: 4x/8x Form A relays (250 VAC/30 VDC, 3 A) DATA OUTPUT Protocol: ASCII, MESSBUS, MODBUS - RTU, PROFIBUS Data format: 8 bit + no parity + 1 stop bit 7 bit + even parity + 1 stop bit (Messbus) Rate: 600115 200 Baud 9 600 Baud12 Mbaud (PROFIBUS) RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 10 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 150 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 /12 V or 1 000 /24 V) POWER SUPPLY 1030 V AC/DC, 10%, max. 13,5 VA 80250 V AC/DC, 10%, max. 13,5 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 120 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 1,5/2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP65 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 670 V (PI), 300 V (DI) input, output, Exc. > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 Seismic capacity: IEC 980: 1993, par. 6

PI - Primary insulation, DI - Double insulation

Measuring ranges
OMU 408UNI is a multifunction instrument available in following types and ranges DC: PM: OHM: RTD: Cu: Ni: T/C: DU: 60/150/300/1 200 mV 05 mA/020 mA/420 mA/2 V/5 V/10 V 0100 /01 k/010 k/0100 k Pt 100/Pt 500/Pt 1 000 Cu 50/Cu 100 Ni 1 000/Ni 10 000 J/K/T/E/B/S/R/N/L Linear potentiometer (min. 500 )

The inputs do not have galvanic separation among themselves! Maximum difference between the GND brackets is 0,2V - DC, PM, TC, DU (internally connected through resistors 100R) Brackets E - have to be on the same potential - OHM, RTD-Pt, RTD-Ni, RTD-Cu (internal galvanic connection)

Connection
POWER SUPPLY N
B
25 26 27 2 3

Order code

OMU 408UNI
1030 V AC/DC 80250 V AC/DC Number of inputs 4 inputs 8 inputs Comparators none 4 relays 8 relays Output none Analog RS 232 RS 485 PROFIBUS Date record no RTC FAST Display color red green Identication of channel and measuring units have Power supply
second color
L8 L4 L3 L7 L6 L2 L1 L5

0 1 0 1 0 1 2 0 1 2 3 4 0 1 2 1 2

232

GND Rx/TxRx/Tx+

485

L
A

+ C D E F G H I J K L M N O

28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47

8 7 6 5 4 3 2 1
7 8

9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24

CJC

GND TxD RxD

- + +
INPUT - U INPUT - I GND
E+ E+ ES+ S+ SS+

- + +
INPUT - U INPUT - I GND
E-- E+ ES-- E+ ES- ES+ S+ SS+

- + +
INPUT - U INPUT - I GND
E-- E+ ES-- E+ ES- ES+ S+ SS+

- + +
INPUT - U INPUT - I GND

DC, PM

*Recording measured values in the FAST mode is feasible from odd channels 1, 3, 5 and 7 only.

RTD, OHM, Ni
E-- E+ ES-- E+ ES- ES+ S+ SS+ E-ES-ES-

GND AO-I AO-U

+ +

GND EXT. 1 EXT. 2 EXT. 3

T/C

DU

ORBIT MERRET 2008.1 en

34

OMB 402
Horizontal bargraph 1 x 30 LED with display Multifunction device (DC, PM, RTD, T/C, DU) Digital filters, Tare, Linearization Size of DIN 96 x 48 mm Power supply 80250 V AC/DC
Options
Excitation Comparators Data output Analog output Data record Power supply: 1030 V AC/DC

OMB 402UNI

DC VOLTMETER AND AMMETER PROCESS MONITOR OHMMETER THERMOMETER FOR Pt, Cu THERMOMETER FOR Ni THERMOMETER FOR THERMOCOUPLES DISPLAY UNIT FOR LINEAR POTENTIOMETERS

OMB 402PWR OMB 402UQC


Description

AC NETWORK ANALYSER UNIVERSAL COUNTER

FROM-TO. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII/MESSBUS/MODBUS/PROFIBUS protocol. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current. The value of analog output corresponds with the displayed data and its type and range are selectable in menu. Measured data record is an internal time control of data collection. It is suitable where it is necessary to register measured values. Two modes may be used. FAST is designed for fast storage (40 records/s) of all measured values up to 8 000 records. Second mode is RTC, where data record is governed by Real Time with data storage in a selected time segment and cycle. Up to 130 000 values may be stored in the instrument memory. Data transmis sion into PC via serial interface RS232/485 and OM Link. Standard functions PROGRAMMABLE PROJECTION Selection: of input type and measuring range Measuring range: adjustable as fixed or with automatic change Measuring modes (PWR): voltage (VRMS), current (ARMS), real power (W), frequency (Hz) and with calculation of Q, S, cos Setting: manual, in menu optional projection on the display may be set for both limit values of the input signal Projection: 30 LED + 6 digit auxiliary display COMPENSATION of conduct (RTD, OHM): automatic (3- and 4-wire) or manual in menu (2-wire) of CJC (T/C): manual or automatic, in menu it is possible to perform selection of the type of thermocouple and compensation of cold junctions, which is adjustable or automatic (temperature at the input brackets) LINEARIZATION Linearization (DC, PM, DU): by linear interpolation in 50 points (solely via OM Link) DIGITAL FILTERS Filtration constant (UC): transmits input signal up to 102 000 Hz Floating/Exp./Arithmetic average: from 230/100/100 measurements Rounding: setting the projection step for display MATHEMATIC FUNCTIONS Min/max. value: registration of min/max. value reached during measurement Tare: designed to reset display upon non-zero input signal Peak value: the display shows only max. or min. value Mat. operations: polynome, 1/x, logarithm, exponential, power, root, sin x and at the same time between inputs - sum, difference, product, quotient EXTERNAL CONTROL Lock control keys blocking Hold display/instrument blocking Tare tare activation Resetting MM resetting min/max value

The OMB 402 model series are panel programmable three-color bar graphs with auxiliary display designed for maximum efficiency and user comfort while maintaining its favourable price. Three versions are available: UNI, PWR and UQC. The OMB 402UNI is a multifunction instrument with the option of configuration for 8 various input options, easily configurable in the instrument menu. The instrument is based on an 8-bit microcontroller with a multichannel 24-bit sigma-delta converter, which secures high accuracy, stability and easy operation of the instrument. Operation The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument may be performed in three adjusting modes: Light menu is protected by optional number code and contains solely items necessary for instrument setting Profi menu is protected by optional number code and contains complete instrument setting User menu may contain arbitrary items from the programming menu (LIGHT/PROFI), which determine the right (see, change). Access w/o password. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). The program is also designed for visualization and filing of measured values from more instruments . All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). Options Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 5...24 VDC. Comparators are assigned to monitor one, two, three or four limit values with relay output. The user may select limits regime: LIMIT/DOSING/

35

Technical data
PROJECTION Display: 30 three-color LED with 6 digit aux.display (9,1mm) Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,1 % of range + 1 digit 0,15 % of range + 1 digit (RTD, T/C) 0,3 % of range + 1 digit (PWR) The accur. applies for project. 9999 and rate 5 (2,5) meas./s (PWR) Accuracy of cold junction measurement: 1C Rate: 1,340 meas./s, 0,55 meas./s (PWR) Overload capacity: 10x (t < 30 ms) - not for > 250 V, 5 A; 2x Measuring modes (PWR): voltage (VRMS), current (ARMS), real power (W), frequency (Hz) and with calculation of Q, S, cos Linearization: by linear interpolation in 50 points Time base (UQC): 0,0550 s Calibration constant (UQC): 0,00001999999 Filtration constant (UQC): 0/10/20/45/55//1000/2000 Hz PRESET (UQC): 0999999 Digital filters: Exp./Floating/Arithmetic average, Rounding Functions: Offset, Min/max value, Tare, Peak value, Mat. operations Ext. control: HOLD, LOCK, Tare, Reset Data record: measured data record into instrument memory RTC - 15 ppm/C, time-date-display value, < 130k data FAST - display value, < 8k data Watch-dog: reset after 1,2 s OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 30 ms Limits: -99999999999 Hysteresis: 0999999 Delay: 099,9 s Output: 2x relays Form A (250 VAC/30 VDC, 3 A) and 2x Form C relays (250 VAC/50 VDC, 3 A), 2x/4x open collectors, 2x SSR, 2x bistable relays DATA OUTPUT Protocol: ASCII, MESSBUS, MODBUS - RTU, PROFIBUS Data format: 8 bit + no parity + 1 stop bit 7 bit + even parity + 1 stop bit (Messbus) Rate: 600115 200 Baud 9 600 Baud12 Mbaud (PROFIBUS) RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 10 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 150 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 /12 V or 1 000 /24 V) EXCITATION Adjustable: 524 VDC/max. 1,2 W POWER SUPPLY 1030 V AC/DC, 10%, max. 13,5 VA 80250 V AC/DC, 10%, max. 13,5 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 96 x 48 x 120 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP65 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 670 V (PI), 300 V (DI) input, output, Exc. > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 Seismic capacity: IEC 980: 1993, par. 6

PI - Primary insulation, DI - Double insulation

Measuring ranges
OMB 402 is a multifunction instrument available in following types and ranges type UNI, standard (code 0) DC: 60/150/300/1 200 mV PM: 05 mA/020 mA/420 mA/2 V/5 V/10 V/40 V OHM: 0100 /01 k/010 k/0100 k RTD: Pt 100/Pt 500/Pt 1 000 Cu: Cu 50/Cu100 Ni: Ni 1 000/Ni 10 000 T/C: J/K/T/E/B/S/R/N/L DU: Linear potentiometer (min. 500 ) type UNI, option A DC: 0,1/0,25/0,5/2/5 A/100 V/25 V/500 V type PWR input U: input I: 010 V/0120 V/0250 V/0450 V 060 mV/0150 mV/0300 mV/01 A/02,5 A/05 A Order code specification
w/o A UNI 0 = Standard 0,1/0,25/0,5/2/5 A 100/250/500 V 060/150/300 mV 01/2,5/5 A 010/120 V 0250/450 V on request PWR PWR UQC contact, TTL, NPN/PNP

K P S U Z

on request

on request

type UQC Measuring mode (UQC): 2x UP or DW counter, UP or DW counter + frequency, UP/DW counter, UP/DW counter for IRC + frequency, timer/clock/phase (0,02100 kHz/200 kHz for IRC)

Connection

Order code

OMB 402
C3 C4 E3 E4 Open collectors OMB 4x2UQC
F

SSR

+ + + + + + +

INPUT C2/RESET INPUT B2 INPUT A2 INPUT C1/RESET INPUT B1 INPUT A1 GND Excitation Option A PWR

Relays

10

11 12 13

RxD/L+ TxD/LGND GND AO-I AO-U

INPUT - U

INPUT - U INPUT - U

- *GND - U/I0,5 - *GND - I5 +


INPUT - I

GND - U GND - I INPUT - I

5 6

14 15 16 17 18 19 20 21 22 23

CJC

E N POWER SUPPLY
Excitation EXT. 1 EXT. 2 EXT. 3

- + +
INPUT - U INPUT - I GND

DC, PM

RTD, OHM, Ni Open collectors E1 C1 E2 C2


E+ E+ ES+ S+ SS+ E-ES-ES-

T/C

U N I P W R Order code shall not include blank spaces! U Q C* Power supply 1030 V AC/DC 80250 V AC/DC Option, see table Measuring ranges Comparators none 1x relay (Form A) 2x relays (Form A) 3x relays (2x Form A + 1x Form C) 4x relays (2x Form A + 2x Form C) 2x open collector 4x open collector 2x open collector + 2x relays (Form C) 2x relays (Form C) 2x SSR 2x bistable relays 1x relay (Form C) Analog output no yes (compensation < 500 /12 V) yes (compensation < 1 000 /24 V) Data output none RS 232 RS 485 MODBUS PROFIBUS Excitation no yes Data record no RTC FAST (only for UNI) Display color red green Type

G H

0 1 ? 0 1 2 3 4 5 6 7 8 9 A B 0 1 2 0 1 2 3 4 0 1 0 1 2 1 2

IV V VI

A B C

DU

*GND (Option A) has a galvanic connection with EXT input and OM Link connector

L3 L L1

L4
III II I

L2

* Scheduled for distribution 1.Q/2008 For complete technical parameters of OMB 402UQC see the universal counter OM 602UQC ORBIT MERRET 2008.1 en

36

OMB 412
Vertical bargraph 1 x 24 LED with display Multifunction device (DC, PM, RTD, T/C, DU) Digital filters, Tare, Linearization Size of DIN 48 x 96 mm Power supply 80250 V AC/DC
Options
Excitation Comparators Data output Analog output Data record Power supply: 1030 V AC/DC

OMB 412UNI

DC VOLTMETER AND AMMETER PROCESS MONITOR OHMMETER THERMOMETER FOR Pt, Cu THERMOMETER FOR Ni THERMOMETER FOR THERMOCOUPLES DISPLAY UNIT FOR LINEAR POTENTIOMETERS

OMB 412PWR OMB 412UQC


Description

AC NETWORK ANALYSER UNIVERSAL COUNTER

FROM-TO. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII/MESSBUS/MODBUS/PROFIBUS protocol. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current. The value of analog output corresponds with the displayed data and its type and range are selectable in menu. Measured data record is an internal time control of data collection. It is suitable where it is necessary to register measured values. Two modes may be used. FAST is designed for fast storage (40 records/s) of all measured values up to 8 000 records. Second mode is RTC, where data record is governed by Real Time with data storage in a selected time segment and cycle. Up to 130 000 values may be stored in the instrument memory. Data transmis sion into PC via serial interface RS232/485 and OM Link. Standard functions PROGRAMMABLE PROJECTION Selection: of input type and measuring range Measuring range: adjustable as fixed or with automatic change Measuring modes (PWR): voltage (VRMS), current (ARMS), real power (W), frequency (Hz) and with calculation of Q, S, cos Setting: manual, in menu optional projection on the display may be set for both limit values of the input signal Projection: 24 LED + 6 digit auxiliary display COMPENSATION of conduct (RTD, OHM): automatic (3- and 4-wire) or manual in menu (2-wire) of CJC (T/C): manual or automatic, in menu it is possible to perform selection of the type of thermocouple and compensation of cold junctions, which is adjustable or automatic (temperature at the input brackets) LINEARIZATION Linearization (DC, PM, DU): by linear interpolation in 50 points (solely via OM Link) DIGITAL FILTERS Filtration constant (UC): transmits input signal up to 102 000 Hz Floating/Exp./Arithmetic average: from 230/100/100 measurements Rounding: setting the projection step for display MATHEMATIC FUNCTIONS Min/max. value: registration of min/max. value reached during measurement Tare: designed to reset display upon non-zero input signal Peak value: the display shows only max. or min. value Mat. operations: polynome, 1/x, logarithm, exponential, power, root, sin x and at the same time between inputs - sum, difference, product, quotient EXTERNAL CONTROL Lock control keys blocking Hold display/instrument blocking Tare tare activation Resetting MM resetting min/max value

The OMB 412 model series are panel programmable three-color bar graphs with auxiliary display designed for maximum efficiency and user comfort while maintaining its favourable price. Three versions are available: UNI, PWR and UQC. The OMB 412UNI is a multifunction instrument with the option of configuration for 8 various input options, easily configurable in the instrument menu. The instrument is based on an 8-bit microcontroller with a multichannel 24-bit sigma-delta converter, which secures high accuracy, stability and easy operation of the instrument. Operation The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument may be performed in three adjusting modes: Light menu is protected by optional number code and contains solely items necessary for instrument setting Profi menu is protected by optional number code and contains complete instrument setting User menu may contain arbitrary items from the programming menu (LIGHT/PROFI), which determine the right (see, change). Access w/o password. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). The program is also designed for visualization and filing of measured values from more instruments . All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). Options Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 5...24 VDC. Comparators are assigned to monitor one, two, three or four limit values with relay output. The user may select limits regime: LIMIT/DOSING/

37

Technical data
PROJECTION Display: 24 three-color LED with 3-digit aux.display (9.1mm) Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,1 % of range + 1 digit 0,15 % of range + 1 digit (RTD, T/C) 0,3 % of range + 1 digit (PWR) The accur. applies for project. 9999 and rate 5 (2,5) meas./s (PWR) Accuracy of cold junction measurement: 1C Rate: 1,340 meas./s, 0,55 meas./s (PWR) Overload capacity: 10x (t < 30 ms) - not for > 400 V, 5 A; 2x Measuring modes (PWR): voltage (VRMS), current (ARMS), real power (W), frequency (Hz) and with calculation of Q, S, cos Linearization (DC, PM, DU): by linear interpolation in 50 points Time base (UQC): 0,0550 s Calibration constant (UQC): 0,00001999999 Filtration constant (UQC): 0/10/20/45/55//1000/2000 Hz PRESET (UQC): 0999999 Digital filters: Exp./Floating/Arithmetic average, Rounding Functions: Offset, Min/max value, Tare, Peak value, Mat. operat. Ext. control: HOLD, LOCK, Tare, resetting Data record: measured data record into instrument memory RTC - 15 ppm/C, time-date-display value, < 130k data FAST - display value, < 8k data Watch-dog: reset after 1,2 s OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 10 ms Limits: -99999999999 Hysteresis: 0999999 Delay: 099,9 s Output: 2x relays Form A (250 VAC/30 VDC, 3 A) and 2x Form C relays (250 VAC/50 VDC, 3 A), 2x/4x open collectors, 2x SSR, 2x bistable relays DATA OUTPUT Protocol: ASCII, MESSBUS, MODBUS - RTU, PROFIBUS Data format: 8 bit + no parity + 1 stop bit 7 bit + even parity + 1 stop bit (Messbus) Rate: 600115 200 Baud 9 600 Baud12 Mbaud (PROFIBUS) RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 10 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 40 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 /12 V or 1 000 /24 V) EXCITATION Adjustable: 524 VDC/max. 1,2 W POWER SUPPLY 1030 V AC/DC, 10%, max. 13,5 VA 80250 V AC/DC, 10%, max. 13,5 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: 48 x 96 x 120 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP65 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 600 V (PI), 300 V (DI) input, output, Exc. > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 Seismic capacity: IEC 980: 1993, par. 6

PI - Primary insulation, DI - Double insulation

Measuring ranges
OMB 412 is a multifunction instrument available in following types and ranges type UNI, standard (code 0) DC: 60/150/300/1 200 mV PM: 05 mA/020 mA/420 mA/2 V/5 V/10 V/40 V OHM: 0100 /01 k/010 k/0100 k RTD: Pt 100/Pt 500/Pt 1 000 Cu: Cu 50/Cu100 Ni: Ni 1 000/Ni 10 000 T/C: J/K/T/E/B/S/R/N/L DU: Linear potentiometer (min. 500 ) type UNI, option A DC: 0,1/0,25/0,5/2/5 A/100 V/25 V/500 V type PWR input U: input I: 010 V/0120 V/0250 V/0450 V 060 mV/0150 mV/0300 mV/01 A/02,5 A/05 A Order code specification
w/o A UNI 0 = Standard 0,1/0,25/0,5/2/5 A 100/250/500 V 060/150/300 mV 01/2,5/5 A 010/120 V 0250/450 V on request PWR PWR UQC contact, TTL, NPN/PNP

K P S U Z

on request

on request

type UQC Measuring mode (UQC): 2x UP or DW counter, UP or DW counter + frequency, UP/DW counter, UP/DW counter for IRC + frequency, timer/clock/phase (0,02100 kHz/200 kHz for IRC)

Connection
C3 C4 E3 E4 Open collectors OMB 4x2UQC
E F

Order code

OMB 412
U N I P W R Order code shall not include blank spaces! U Q C* Power supply 1030 V AC/DC 80250 V AC/DC Option, see table Measuring ranges Comparators none 1x relay (Form A) 2x relays (Form A) 3x relays (2x Form A + 1x Form C) 4x relays (2x Form A + 2x Form C) 2x open collector 4x open collector 2x open collector + 2x relays (Form C) 2x relays (Form C) 2x SSR 2x bistable relays 1x relay (Form C) Analog output no yes (compensation < 500 /12 V) yes (compensation < 1 000 /24 V) Data output none RS 232 RS 485 MODBUS PROFIBUS Excitation no yes Data record no RTC FAST (only for UNI) Display color red green Type

SSR

+ + + + + + +

INPUT C2/RESET INPUT B2 INPUT A2 INPUT C1/RESET INPUT B1 INPUT A1 GND Excitation Option A PWR

G H

0 1 ? 0 1 2 3 4 5 6 7 8 9 A B 0 1 2 0 1 2 3 4 0 1 0 1 2 1 2

Relays

10

11 12 13

RxD/L+ TxD/LGND GND AO-I AO-U

IV V VI

A B C

5 6

14 15 16 17 18 19 20 21 22 23

L3

L4
III II I

INPUT - U

INPUT - U INPUT - U

- *GND - U/I0,5 - *GND - I5


INPUT - I

GND - U GND - I INPUT - I

CJC

E N POWER SUPPLY
Excitation EXT. 1 EXT. 2 EXT. 3

- + +
INPUT - U INPUT - I GND

DC, PM

*GND (Option A) has a galvanic connection with EXT input and OM Link connector

L1
E1 C1 E2

L2
C2

RTD, OHM, Ni Open collectors


E+ E+ ES+ S+ SS+ E-ES-ES-

T/C

DU

* Scheduled for distribution 1.Q/2008 For complete technical parameters of OMB 412UQC see the universal counter OM 602UQC ORBIT MERRET 2008.1 en

38

OMB 200/300/500
Three-color bargraph 20/30/50 LED Multifunction input (PM, OHM, RTD, DU) Digital filter, Linearization Voltage 1030 V AC/DC
Options
Comparators

OMB 200UNI OMB 300UNI OMB 500UNI

1x 20 LED 1x 30 LED 1(2)x 50 LED PROCESS MONITOR OHMMETER THERMOMETER FOR Pt THERMOMETER FOR Ni DISPLAY UNIT FOR LINEAR POTENTIOMETERS DATA DISPLAY

Standard function PROGRAMMABLE PROJECTION Selection: of type of input measuring range Setting: manual, in menu optional projection on the display may be set for both limit values of the input signal Projection: 20, 30 or 50 LED LINEARIZATION Linearization: by linear interpolation in 25 points (solely via OM Link) DIGITAL FILTERS Exponential average: from 2100 measurements Rounding: setting the projection step for display EXTERNAL CONTROL Hold display/instrument blocking Lock control keys blocking

OMB x00RS
Description

The OMB 200/300/500UNI model series are simple bargraphs designed for maximum efficiency and user comfort while maintaining its low cost. The OMB 200/300/500UNI type is a multifunction instrument with the option of configuration for 5 different types of inputs easily configurable in the instrument menu. The instrument is based on an 8-bit microcontroller with A/D converter, which secures good accuracy, stability and easy operation of the instrument. Another version of the OMB 200/300/500 instrument is the RS type, a display device for projection of data from serial line RS 232/485. By selecting the mode of insertion of the front plexiglass (reverse/face) you may choose the required printing of scale for vertical or horizontal design of the instrument.

Operation

The instrument is set and controlled by five control keys located on the front panel. All programmable settings of the instrument may be performed in two adjusting modes: Profi menu contains complete instrument setting Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). Options Comparators are assigned to monitor two limit values with relay output. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay.

N E W

39

Technical data
PROJECTION Display: three-color LED (red/green/orange) OMB 200 - 20 LED OMB 300 - 30 LED OMB 500 - 50 LED OMB 502 - 2x 50 LED Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 1 % of range + 1 digit Rate: 0,5/5/50/max. measurements/s Overload capacity: 10x (t < 30 ms); 2x Watch-dog: reset after 20 ms Functions: HOLD, LOCK, Digital filters OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 50 ms Limits: within full range Hysteresis: positive values Delay: 099,9 s Output: 1(2)x bistable relays (250 VAC/30 VDC, 3 A) POWER SUPPLY 1030 VDC/24 VAC, 10%, max. 3 VA
PI - Primary insulation, DI - Double insulation

MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I Dimensions: OMB 200 72 x 24 x 100 mm OMB 300 96 x 24 x 100 mm OMB 500 144 x 48 x 75 mm Panel cutout: OMB 200 68 x 22,5 mm OMB 300 92 x 22,5 mm OMB 500 138 x 43,5 mm OPERATING CONDITIONS Connection: connectors, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP40 (front panel only) El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 300 V (PI), 300 V (DI) input, output, Exc. > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2

Measuring ranges
OMB 200/300/500UNI is a multifunction instrument available in following types and ranges PM: OHM: RTD: Ni: DU: 020 mA/420 mA/02 V/ 05 V /010 V 0100 k Pt 1000/KTY/Termistor Ni 1 000 Linear potentiometer (min. 500 ) Connecting individual inputs
PM OHM RTD NI DU INPUT 1 020 mA, 4 20 mA INPUT 2 0 2 V/05 V/010 V

0100 k Pt 1 000/KTY/Termistor Ni 1 000 Linear potentiometer (min. 500 )

typ OMB xxxRS RS: input RS 232/RS 485, protocol ASCII/MODBUS - RTU

Connection

Order code

OMB
Type
2 3 5 5 0 0 0 0 0 0 0 2

UNI RS -

Comparator

POWER SUPPLY

* Only for type OMB 300 a OMB 500/502

no 1x relay *2x relays

0 1 2

Hold/Lock GND INPUT 1 INPUT 2

ES+

+ + -

ES-

L2

+
PM

1 2 3 4
5 6 7 8

L1

OM Link
RTD/OHM DU RS - 232 Hold/Lock GND TxD RxD
RS 232

RS - 485

LL+

RS 485

9 10 11

ORBIT MERRET 2008.1 en

40

OMD 201
4/6-digit programmable projection Three-color LED, digit height 57; 100; 125 mm IR remote control Digital filter, Tare Power supply 230 VAC
Options
Excitation Comparators Data output Analog output Power supply 1030 V AC/DC

OMD 201UNI

DC VOLTMETER AND AMMETER PROCESS MONITOR OHMMETER THERMOMETER FOR Pt, Cu, Ni THERMOMETER FOR THERMOCOUPLES DISPLAY UNIT FOR LINEAR POTENTIOMETERS

well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII/MESSBUS/MODBUS/PROFIBUS protocol. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output - voltage/current. The value of analog output corresponds with the displayed data and its type and range are selectable in menu. Standard functions PROGRAMMABLE PROJECTION Selection: of input type and measuring range Measuring range: adjustable as fixed or with automatic change Setting: manual, in menu optional projection on the display may be set for both limit values of the input signal Measuring modes (PWR): voltage (VRMS), current (ARMS), real power (W), frequency (Hz) and with calculation of Q, S, cos Setting (UQC): measuring mode 2x counter (UP/DW, IRC)/2x frequency/timer/clock with adjustable calibration coefficient, time base and projection Projection: -9999999/-99999999999, for version UQC there are selectable also time formats, user-adjustable display color also with measuring units (red-greenorange) COMPENSATION

OMD 201PWR OMD 201UQC OMD 201RS


Description

The OMD 201 model series are large programmable displays, which are produced in many designs. The instrument is based on an 8-bit processor and a precise A/D converter, which secures high accuracy, stability and easy operation of the instrument. Displays are designed for indoor and outdoor use with IP64 cover. Displays are suitable for projection of measured data in productions lines and operations with legibility up to 80 m. Holder for wall mounting applications may be supplied on request.

Operation The instrument is set and controlled by IR remote control. All programmable settings of the instrument may be performed in three adjusting modes: Light menu is protected by optional number code and contains solely items necessary for instrument setting Profi menu is protected by optional number code and contains complete instrument setting User menu may contain arbitrary items from the programming menu (LIGHT/PROFI), which determine the right (see, change). Access w/o password. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates (with OML cable). The program is also designed for visualization and filing of measured values from more instruments . All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). The measured units may be projected on the 6 digit display. Options Excitation is suitable for feeding of sensors and transmitters. It is isolated, with continuously adjustable value in the range of 5...24 VDC. Comparators are assigned to monitor one, two, three or four limit values with relay output. The user may select limits regime: LIMIT/DOSING/FROMTO. The limits have adjustable hysteresis within the full range of the display as

AC NETWORK ANALYSER UNIVERSAL COUNTER DATA DISPLAY

of conduct (RTD): automatic (3- and 4-wire) or manual in menu (2-wire) of CJC (T/C): manual or automatic LINEARIZATION Linearization (DC, PM, DU): by linear interpolation in 50 points (solely via OM Link) DIGITAL FILTERS

Input filter (UQC): transmits input signal up to 102 000 Hz Floating/Exp./Arithmetic average: from 230/100/100 measurements Rounding: setting the projection step for display

FUNCTIONS

Preset (UQC): initial non-zero value, which is always read after resetting the instrument to zero Summation (UQC): registration of the number upon shift operation Pre-division constant (UQC): 1/10/60/100/1 000/3 600 Min/max. value: registration of min/max. value reached during measurement Tare: designed to reset display upon non-zero input signal Peak value: the display shows only max. or min. value Mat. operations: polynome, 1/x, logarithm, exponential, power, root, sin x

EXTERNAL CONTROL Hold: display/instrument blocking Lock: control keys blocking Tare: tare activation Resettting: resetting the min/max value, resetting counter/stopwatch/timer

41

Technical data
PROJECTION Display: 4 (100/125 mm) or 6 digit (57/100/125 mm) Three-color LED - red/green/orange Projection: -9999999/-99999999999 for version UQC there are selectable also time formats Decimal point: setting - in menu Brightness: setting - in menu INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,1 % of range + 1 digit 0,15 % of range + 1 digit (RTD, T/C) 0,3 %(0,6/0,9%) of range + 1 digit (PWR) The accur. applies for project. 9999 and rate 5 (2,5) meas./s (PWR) 0,01 % of range + 1 digit (UQC) Accuracy of cold junction measurement: 1C Rate: 1,340 meas./s, 0,55 meas./s (PWR) Overload capacity: 10x (t < 30 ms) - not for > 250 V, 5A; 2x Measuring modes (PWR): voltage (VRMS), current (ARMS), real power (W), frequency (Hz) and with calculation of Q, S, cos Linearization: by linear interpolation in 50 points Dato protocol (RS): ASCII, MessBus, Modbus-RTU, Profibus DP Time base (UQC): 0,0550 s Calibration constant (UQC): 0,00001999999 Input filters (UQC): 0/10/20/45/55//1 000/2 000 Hz PRESET (UQC): 0999999 Digital filters: Exp./Floating/Arithmetic average, Rounding Function: Offset, Min/max.value, Tare, Peak value, Math. operation Ext. control: HOLD, LOCK, Tare, Resetting Watch-dog: reset after 0,4 s OM Link: Company communication interface for instrument control, setting and update Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 30 ms Limits: -99999999999 Hysteresis: 0999999 Delay: 099,9 s Output: 4x Form C relays (250 VAC/30 VDC, 3 A) DATA OUTPUT Protocol: ASCII, MESSBUS, MODBUS - RTU, PROFIBUS DP Data format: 8 bit + no parity + 1 stop bit (ASCII) 7 bit + even parity + 1 stop bit (DIN Messbus) Rate: 600230 400 Baud 9 600 Baud12 Mbaud (PROFIBUS) RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 10 000 points, AO corresponds with the displayed data, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 150 ms Ranges: 02/5/10 V, 05 mA, 0/420 mA (comp. < 500 /12 V or 1 000 /24 V) EXCITATION Adjustable: 524 VDC/max. 1,2 W POWER SUPPLY 1030 V AC/DC, 10%, max. 27 VA 80250 V AC/DC, 10%, max. 27 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: Anodized aluminium, black Dimensions: in mm
LED 57 100-4 100-6 125-4 125-6 lenght 372 465 651 539 754 height 116 181 181 237 237 depth 88 88 88 88 88 cutout 364 x 108 457 x 173 643 x 173 531 x 228 746 x 228

OPERATING CONDITIONS Connection: connectors, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP64 Construction: safety class I El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. power supply > 670 V (PI), 300 V (DI) input, output, Exc. > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 OPTIONS holder for wall installation
PI - Primary insulation, DI - Double insulation

Measuring ranges
OMD 201 is a multifunction instrument available in following types and ranges type UNI, standard (code 0) DC: 60/150/300/1 200 mV PM: 05 mA/020 mA/420 mA/2 V/5 V/10 V/40 V OHM: 0100 /01 k/010 k/0100 k RTD: Pt 100/Pt 500/Pt 1 000 Cu: Cu 50/Cu100 Ni: Ni 1 000/Ni 10 000 T/C: J/K/T/E/B/S/R/N/L DU: Linear potentiometer (min. 500 ) type UNI, option A DC: 0,1/0,25/0,5/2/5 A/100 V/25 V/500 V type UNI, option B (expansion about three inputs) PM: 3x 05 mA/020 mA/420 mA/2 V/5 V/10 V/40 V type PWR input U: input I: 010 V/0120 V/0250 V/0450 V 060 mV/0150 mV/0300 mV/01 A/02,5 A/05 A Order code specifications
UNI w/o 0 = Standard 0,1/0,25/0,5 /2/5 A 100/250/500 V expansion about three inputs (PM) PWR PWR UQC contact, TTL, NPN/PNP RS

RS 232/485

B C K P S U Z

MODBUS PROFIBUS 060/150/300 mV 01/2,5/5 A 010/120 V 0250/450 V on request

type UQC Measuring mode (UQC): 2x UP or DW counter, UP or DW counter + frequency, UP/DW counter, UP/DW counter for IRC + frequency, timer/clock/phase (0,02100 kHz/200 kHz for IRC)

on request

on request

Connection

Order code

OMD 201
N I W R Q C Order code shall not include blank spaces! R S Power supply 1030 V AC/DC 80250 V AC/DC Measuring range, see table Measuring ranges Comparators no 1x Ralay 2x Relays 3x Relays 4x Relays Analog output none yes (comp. < 500 /12 V) yes (comp. < 1 000 /24 V) Data output none RS 232 RS 485 MODBUS PROFIBUS Excitation no yes Digit height 57 mm 100 mm 125 mm Number of digits 4 digits (100/125 mm) 6 digits Type U P U

0 1 ? 0 1 2 3 4 0 1 2 0 1 2 3 4 0 1 1 2 3 1 3

To preserve the IP64 cover the display connection is realized through bushings directly to terminal board inside the instrument.

ORBIT MERRET 2008.1 en

42

OMX 38
Isolated transmitters to DIN rail Power supply 230 VAC
Options
Power supply: 24/110 VAC, 1030 VDC

OMX 38DC OMX 38AC OMX 38PM OMX 38W OMX 38OHM OMX 38RTD OMX 38DU

DC VOLTMETER AND AMMETER AC VOLTMETER AND AMMETER PROCESS MONITOR WATTMETER OHMMETER THERMOMETER FOR Pt /Ni LINEAR POTENTIOMETERS

Description The OMX 38 model series are low-price and simple analog transmitters with mounting to 35 mm wide DIN rail. Transmitters have galvanic separation with isolation voltage of 300 V and thus they are suitable as primary isolation for majority of industrial applications. Operation

The transmitter is designed for simple measurement without further control.

Calibration

By trimmers accessible from the face of the transmitter we may adjust the range of output signal within the range of 10%.

43

Technical data
INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,1 % of range 0,2 % of range (RTD, OHM) 0,3 % of range (AC) 0,5 % of range (W) Rate: continuous measurement Overload capacity: 10x (t < 30 ms) - not for > 300 V, 5A; 2x Calibration: at 25C and 40 % r.h. ANALOG OUTPUT Type: isolated, fixed setting TC: 100 ppm/C Rate: response to change of value < 1 ms response to change of value < 1 s (AC, W, RTD, OHM) Voltage: 02 V, 05 V, 010 V, on request 10 V (minimum load 1 k) Current: 020 mA, 420 mA, on request 20 mA (< 500 ) Ripple: 5 mV residual ripple at output voltage of 10 V POWER SUPPLY 24; 110; 230 VAC, 50/60 Hz, 10 %, 3 VA 1030 VDC/max. 150 mA, isolated Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: PA 66, incombustible UL 94 V-I, blue Dimensions: 113 x 98 x 22 mm Installation: to DIN rail 35 mm wide OPERATING CONDITIONS Connection: terminal board, section < 2,5 mm 2 Stabilization period: within 5 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP20 El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. AC power supply > 600 V (PI), 300 V (DI) DC power supply, input, output, Exc. > 500 V (PI), 250 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2

PI - Primary insulation, DI - Double insulation

Measuring ranges
PM w/o A B C D E F H J K N P R S T U Z 05 mA 020 mA 420 mA 02 V 05 V 010 V 060 mV 0150 mV 0300 mV 01 A 05 A 0120 V 0150 V 0250 V 0450 V on request W W DU 0,5100 k OHM 0,1100 k DC w/o A B C D E F G H I J K L N P R S T U Z 60 mV450 V 5 mA5 A AC 402 500 Hz 60 mV450 V 5 mA5 A RTD -50850C Pt 100 Pt 500 Pt 1 000 Ni 1 000

on request

on request

Connection

Order code

OMX 38
OMX 38DC, PM
POWER Shielding INPUT U INPUT I

D A P

OMX 38DU
Shielding
B E

INPUT U

Shielding

INPUT I

GND

ES+

ES-

ES+

S-

Shielding

S+

E+

S-

E-

E-

OMX 38AC, W

C C M W O H M R T D Order code shall not include blank spaces! D U Power supply 24 VAC/50 Hz 230 VAC/50 Hz 110 VAC/50 Hz 1030 VDC, isolated Measuring range, see table Measuring ranges Connection 2-wire 3-wire 4-wire Type Analog output 02 V 05 V 010 V 020 mA 420 mA 10 V 20 mA 05 mA

+ L

GND

+ + Analog

+
OMX 38RTD

0 1 3 4 ? 1 2 3 1 2 3 4 5 6 7 8

Please, state the input range (from the entire range stated) in your order!

Shielding

output

ORBIT MERRET 2008.1 en

44

OMX 100
Programmable isolated transmitters LCD display, Digital Dig filter, Tare Output: 0/420 mA/05 mA/0,22,2 kHz 02/5/ 02/5/10 V Power supply 2 230 VAC
Options
Excitation Dual comparator Data output Power supply: pp y 24/110 VAC, 1030 10 VDC

OMX 100DC OMX 100PWR OMX 100PM OMX 100OHM OMX 100RTD OMX 100T/C OMX 100DU OMX 100F

DC VOLTMETER AND AMMETER UNIVERSAL WATTMETER PROCESS MONITOR OHMMETER THERMOMETER FOR Pt/Ni THERMOMETER FOR THERMOCOUPLES LINEAR POTENTIOMETERS UNIVERSAL COUNTER FREQUENCY METER

Standard functions PROGRAMMABLE INPUT Setting: manual, in menu it is possible to set for both limit values of the input signal arbitrary type (V, mA, Hz) and range of the analog output as well as projection on the LCD display Setting (F): measuring mode counter/frequency with adjustable calibration coefficient and time base COMPENSATION Conduct (RTD, OHM): automatic (3- and 4-wire) or manual in menu (2-wire) of conduct in probe (RTD): internal connection (conduct resistance in measuring head) of CJC (T/C): manual or automatic, in menu it is possible to perform selection of the type of thermocouple and compensation of cold junctions, which is adjustable or automatic (temperature at the input brackets) DIGITAL FILTERS Exponential average: from 2100 measurements Rounding: setting the projection step for display Filtration constant (F): transmits input signal up to 51 000 Hz FUNCTIONS Preset (F): initial non-zero value, which is always read after resetting the instrument to zero Tare: resetting display upon non-zero input signal EXTERNAL CONTROL Hold: display/instrument blocking Resetting (F): counter resetting Lock: control keys blocking

Description The OMX 100 model series are programmable transmitters. The instrument is based on an 8-bit controller with precise A/D converter, which secures high accuracy, stability and easy operation feasibility. For projection of measured data, easier setting and clear function arrangement is, as a standard, equipped with illuminated LCD display. Transmitters have galvanic separation with isolation voltage of 500 V. Operation The instrument is set and controlled by two control keys located on the front panel or via data line RS 232/485. Standard equipment is the OM Link interface, which together with operation program enables modification and filing of all instrument settings as well as perform firmware updates. All settings are stored in the EEPROM memory (they hold even after the instrument is switched off). The measured units may be projected on the display. Options Excitation is suitable for feeding of sensors and transmitters. It has a galvanic isolation with fixed preset value of 12...15 VDC. Comparators are assigned to monitor two limit values with relay output. The limits have adjustable hysteresis within the full range of the display as well as selectable delay of the switch-on in the range of 0...99,9 s. Reaching the preset limits is signalled by LED and simultaneously by the switch-on of the relevant relay. Data outputs are for their rate and accuracy suitable for transmission of the measured data for further projection or directly into the control systems. We offer an isolated RS232 and RS485 with the ASCII protocol. Analog outputs will find their place in applications where further evaluating or processing of measured data is required in external devices. We offer universal analog output with the option of selection of the type of output voltage/current/frequency. The value of analog output corresponds with the displayed data and its type and range are selectable in menu.

45

Technical data
PROJECTION Display: LCD wtih backlighting, 2x 3 characters + 2x description (3 characters) Description: second and fourth line of LCD display may be used for description of measured quantity, resp. output quantity (setting in menu) Decimal point: setting - in menu INSTRUMENT ACCURACY TC: 100 ppm/C Accuracy: 0,2 % of range + 1 digit 0,3 % of range + 1 digit (PWR, T/C) 0,05 % of range + 1 digit (F) Accuracy of cold junction measurement: 1C Rate: 0,580 meas./s Overload capacity: 10x (t < 30 ms) - not for 200 V a 5A; 2x Resolution: 0,1C (RTD), 1C (T/C), for display Watch-dog: reset after 20 ms Functions: HOLD, LOCK, Digital filters, Tare Linearization (DC, PM, DU): by linear interpolation in 25 points Functions (F): Data backup, Time backup, Preset Input filters (F): Filtration constant, Rounding Time base (F): 0,1/0,5/1/5/10/50 s Calibration constant (F): 0,019999 Hz Filtration constant (F): 0/5/40/100/1 000 Hz PRESET (F): 0999 OM Link: Company communication interface for operation, setting and update of instruments Calibration: at 25C and 40 % r.h. COMPARATOR Type: digital, setting in prog. mode, contact switch < 50 ms Limits: 999, resp. -99999 k Hysteresis: 0999, resp. 999 k Delay: 099,9 s Output: 2x Form A relays (250 VAC/30 VDC, 3 A) DATA OUTPUT Data format: 8 bit + no parity + 1 stop bit Rate: 1 20038 400 Baud RS 232: isolated RS 485: isolated, addressing (max. 31 instruments) ANALOG OUTPUT Type: isolated, programmable with resolution of max. 12 bit, type and range are selectable in programming mode Non-linearity: 0,2 % of range TC: 100 ppm/C Rate: response to change of value < 100 ms Ranges: 02/5/10 V, on request 5 V/10 V 05 mA, 0/420 mA, on request 20 mA, (comp. < 500 ) Ripple: 5 mV residual ripple at output voltage of 10 V Frequency: isolated, programmable, open colector with inside power resistor, 0,22 200 Hz EXCITATION Adjustable: 1224 VDC/25 mA, isolated POWER SUPPLY 24, 110, 230 VAC, 50/60 Hz, 10%, 5 VA 1030 VDC/max. 150 mA, isolated Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: PA 66, incombustible UL 94 V-I, blue Dimensions: 113 x 98 x 35 mm Installation: to DIN rail 35 mm wide OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP20 El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. AC power supply > 600 V (PI), 300 V (DI) DC power supply, input, output, Exc. > 500 V (PI), 250 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 Seismic capacity: IEC 980: 1993, par. 6

PI - Primary insulation, DI - Double insulation

Measuring ranges
DC w/o A B C D E F G H K P S U Z 010/120 V 0250/450 V on request 0,2/2/20/200 V, 2/20 mA 60/150 mV, 1/5 A PWR PWR PM 0/420 mA, 02/5/10 V OHM 0999 09,99 k 099,9 k DU lin. potentiometer > 500 UC contact, TTL, NPN/PNP < 50 kHz counter/frequency timer/clock RTD w/o 1 2 3 4 5 6 7 Pt 100 Pt 500 Pt 1 000 Ni 1 000 Ni 2 226 Ni 10 000 Pt 100 (3920 ppm/C) T/C B R, S, T E, J, K, N

5105 060/150/300 mV 01/2,5/5 A

on request

Connection
OMX 100DC, PM, F
AO - supply OC AO - frequency POWER AO - voltage AO - current
Hold/Lock

Order code
OMX 100DU
B E

OMX 100
D C P M O H M P W R R T D T C Order code shall not include blank spaces! D U F Power supply 24 VAC/50 Hz 230 VAC/50 Hz 110 VAC/50 Hz 1030 VDC, isolated Measuring range, see table Measuring ranges Comparators no yes Output none RS 232 RS 485 Excitation Type

INPUT 1

INPUT 2

+ L

INPUT 1

INPUT 2

INPUT 3

GND

S+

ES+

S-

E-

ES+

ES-

OMX 100T/C
INPUT

232

GND

485

CJC

E+

S-

E-

GND

INPUT 3

+ + +

+
L2

+ +
L1

OMX 100PWR

0 1 3 4 ? 0 1 0 1 2 3

OMX 100RTD

OM Link

GND GND

RxD Rx/Tx+ Exc.

TxD Rx/Tx-

+
ORBIT MERRET 2008.1 en

46

OMX Probus
Transmitter PROFIBUS to RS 485 Dimensions 113 x 98 mm, width 22 mm Power supply 80250 V AC/DC
Options
Power supply 1030 VDC

OMX Profibus

PROFIBUS DP/RS 485

Description

The transmitter is designed for easy and cost-effective connection of ORBIT MERRET instruments to PROFIBUS line. One apparatus may control up to 31 instruments via the RS 485 line with communication protocol OM ASCII. From the OM xxx instruments individual values may be downloaded from as many as 9 channels (for one instrument) as well as limit statuses may be set. Another option is projecting values and texts on displays of individual instruments.

Operation The instrument is designed for transfer of communication among the OM xxx instruments to PROFIBUS bus without further control. On the front panel of the transmitter there are 4 LED diodes for signalization of the operational status and communication in progress.

N E W N E W

47

Technical data
PROFIBUS INPUT Address: 0...125, adjustable in OM instruments w/00address Rate: 9 600 Baud12 Mbaud Data transmission: 54B to OM, 44B from OM Modes: - data downloading + setting limits - projection of FLOAT values (Real)/LONG - projection of texts - sending OM ASCII commands DATA OUTPUT Data format: 8 bit + no parity + 1 stop bit (OM ASCII) Rate: 1 200115 200 Baud RS 485: isolated, addressing (max. 31 instruments) POWER SUPPLY 1030 V AC/DC, 50/60 Hz, 10%, max. 1 VA 100250 V AC/DC, 50/60 Hz, 10%, max. 1 VA Power supply is protected by a fuse inside the instrument MECHANIC PROPERTIES Material: PA 66, incombustible UL 94 V-I, blue Dimensions: 113 x 98 x 22 mm Installation: to DIN rail 35 mm wide OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 15 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP20 El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. AC power supply > 600 V (PI), 300 V (DI) DC power supply, input, output, Exc. > 500 V (PI), 250 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2

PI - Primary insulation, DI - Double insulation

Connection

Order code

OMX Probus
Power supply
POWER SUPPLY PROFIBUS

0 1

1030 V AC/DC, isolated* 80250 V AC/DC, isolated

* Launch for sale has not been set


PROFIBUS
GND LL+

+ L

A
L-

RS 485

GND
L+

B
GND

ORBIT MERRET 2008.1 en

48

OMP 38
Adjustable stabilized source to DIN rail Output 5/12(15)/24 VDC Current and heat protection Power supply 80250 V AC/DC

Description

The OMP 38 is a stabilized source for sensor power supply. The source is in a plastic box with terminal board to DIN rail. On the face of the transmitter there are LEDs, which indicate the operation status of the source.

Operation

Switch for the setting of output voltage is located on the lower edge of the instrument.

49

Technical data
OUTPUT Output: A - 5 VDC/450 mA; 12 VDC/300 mA; 24 VDC/150 mA B - 5 VDC/450 mA; 15 VDC/240 mA; 24 VDC/150 mA (adjustable by a switch on the box) Tolerance: 0,25 V Regulation: 0,1 V Ripple: < 50 mVpp Outage span: > 200 ms Efficiency: 63 % Functions: active current restriction as per selected range, overstepping the restriction is signalled by red LED POWER SUPPLY Range: 100250 V AC/DC, 50/60 Hz, 10%, 5,7 VA Input frequency: DC, 4763 Hz Input current: 10045 mA Starting current: < 20 A, < 1,5 ms Protection: by a fuse inside the instrument (T630mA) MECHANIC PROPERTIES Material: PA 66, incombustible UL 94 V-I, blue Dimensions: 113 x 98 x 22 mm Installation: to DIN rail 35 mm wide OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 5 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP20 El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. Power supply, output > 300 V (PI), 250 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 Seismic capacity: IEC 980: 1993, par. 6

PI - Primary insulation, DI - Double insulation

Connection

Order code

OMP 38
POWER SUPPLY

5/12/24 VDC 5/15/24 VDC

Output

A B

+ L

ORBIT MERRET 2008.1 en

50

OMP 100
Adjustable stabilized stab source to DIN rail Output 5/10, 12/24 12 VDC/96 W Current and heat hea protection Power supply 2 230 VAC

OMP 100

SOURCE - 2x 5 VDC/8 A SOURCE - 2x 12 VDC/4 A

Description

The OMP 100 model is a universal power source with active compensation of power factor. The source is in a plastic box with terminal board to DIN rail. Located on the front of the transmitter there is a bi-color LED, which signals the operational status of the source.

Operation

Output voltage is selected by interconnection of input brackets. Outputs may be operated by parallel, serial or independent connection, as separated with isolation 60 VDC.

N E W N E W

51

Technical data
OUTPUT Output: 2x 5 VDC/8 A, 2x 12 VDC/4 A outputs may be used independently, in parallel or in series Tolerance: 0,25 V Regulation: 0,1 V Ripple: < 50 mVpp Outage span: > 200 ms Efficiency: 80 % Functions: active current restriction as per selected range, overstepping the restriction is signalled by red LED POWER SUPPLY Range: 230 V AC/DC, 50/60 Hz, 10%, 120 VA Input frequency: DC, 4763 Hz Input current: 50045 mA Starting current: < 20 A, < 1,5 ms Protection: by a fuse inside the instrument (T4A) MECHANIC PROPERTIES Material: PA 66, incombustible UL 94 V-I, blue Dimensions: 113 x 98 x 35 mm Installation: to DIN rail 35 mm wide OPERATING CONDITIONS Connection: connector terminal board, section < 2,5 mm 2 Stabilization period: within 5 minutes after switch-on Working temperature: 060C Storage temperature: -1085C Cover: IP20 El. safety: EN 61010-1, A2 Insulation resistance: for pollution degree II, measuring cat. III. Power supply, output > 300 V (PI), 150 V (DI) EMC: EN 61000-3-2+A12; EN 61000-4-2, 3, 4, 5, 8, 11; EN 550222, A1, A2 Seismic capacity: IEC 980: 1993, par. 6

PI - Primary insulation, DI - Double insulation

Connection

Order code

OMP 100
Output
POWER

2x 5 VDC 2x 12 VDC

A B

+ L

ORBIT MERRET 2008.1 en

52

OMA 10S
Manual switch of measuring points 4x 10 Size of DIN 96 x 48 mm

Description

The OMA 10S is a manual panel switch of measuring points. For its parameters, low transitional resistance and high endurance the switch is designed for low-voltage applications (e.g. for sensors Pt 100)
Operation

Switching of the measuring points is performed by revolving switch on the front panel.

53

Technical data
INPUT Connection: 4 x 10 positions - number of positions is adjustable inside the switch (210 x 4) Max. load: 30 VDC/100 mA Max. current switched: 5 mA MECHANIC PROPERTIES Material: Noryl GFN2 SE1, incombustible UL 94 V-I, black Dimensions: 96 x 48 x 120 mm Panel cutout: 90,5 x 45 mm OPERATING CONDITIONS Connection: terminal board, section < 2,5 mm 2 Working temperature: 060C Storage temperature: -1085C Cover: IP40 Insulation resistance: 50 V El. safety: EN 61010-1, A2

PI - Primary insulation, DI - Double insulation

Connection

Order code

OMA 10S

S- 01 E- 01 S- 02 E- 02 S- 03 E- 03 S- 04 E- 04 S- 05 E- 05 S- 06 E- 06 S- 07 E- 07 S- 08 E- 08 S- 09 E- 09 S- 10 E- 10 (S- 11) (E- 11) S+ 01 E+ 01 S+ 02 E+ 02 S+ 03 E+ 03 S+ 04 E+ 04 S+ 05 E+ 05 S+ 06 E+ 06 S+ 07 E+ 07 S+ 08 E+ 08 S+ 09 E+ 09 S+ 10 E+ 10 (S+ 11) (E+ 11) INPUT

S+ E+

SE-

ORBIT MERRET 2008.1 en

54

Cover IP64
Additional cover IP64

For instruments of the OM 36 and OM 47 series

OM USB-RS
Isolated transmitter USB > RS 232/RS 485

FUNCTION Instrument configuration: The transmitter provides galvanic separation of USB bus and RS output. Output lines RS 232 and RS 485 have galvanic connection and via excitors connected to one UART. Therefore it is possible to use always one output only. DATA OUTPUT Rate RS 232: 600460 800 baud Rate RS 485: 600921 600 baud POWER SUPPLY 5 V/100 mA z USB OPERATIONAL CONDITIONS Connector terminal board: conductor section <1,5 mm2 Working temperature: 0 .. 60 C Storage temperature: -10 .. 85 C Insulation capability: for pollution degree II, measuring category III Input/output > 300 V(PI), 150 V(DI) OPTIONS USB A-B cable may be provided with the transmitter
PI - Primary insulation, DI - Double insulation

GENERAL BUSINESS TERMS

1. Basic provisions 1.1. The General business, service and guarantee terms arrange the relations for the delivery of goods and services, hereinafter referred to as the Subject of performance by ORBIT MERRET, spol. s r.o., (hereinafter referred to as the Supplier) to Customers and are binding upon all and any business relations. 1.2. By signing the legally binding acts leading to the establishment of a Supplier-customer relationship of obligatory character, related to the delivery of the Subject of performance by the Supplier, the parties accept that their mutually binding relationship shall be governed in terms of the provisions of Section 262, par. 1 of the Commercial code by regime of the quoted law. Establishment of the arranged binding relationship is always conditioned by the Suppliers acceptance of the Customers order form. 2. Price of the Subject of performance 2.1. Catalogues and pricelists issued by the Supplier as well as oral and telephone information about the price of the Subject of performance are of informative character, not binding for the Supplier and not claimable by the Customer. The Supplier reserves the right to modify technical parameters, or as the case may be, also the prices of the Subject of performance without prior written notice. The Supplier is not responsible for errors generated during the print of the business and technical materials. 2.2. For specication of the price, the Customer is entitled to request a binding quotation (hereinafter referred to as the Quotation), which is valid for a period of 21 calendar days from the date of issue unless provided otherwise. 2.3. Prices of the Subject of performance listed in the Quotation do not include any related services, unless expressly provided for otherwise. Requirement for the provision of related services needs to be stated in the order. 2.4. The Supplier assumes a standard use of the Subject of performance. Any specic requirements for the Subject of performance need to be expressed in the order. 3. Concluding the contract 3.1. Individual business deals are concluded on the basis of written orders from the Customer, sent either by mail or fax, exceptionally also on the basis of oral or telephone order. 3.2. An order has to contain the following elementary properties: - business name and seat of the Customer including telephone and facsimile contact numbers - name of the person authorized to act on behalf of the Customer, Trade Licence No. and Tax identication No. (if the Customer is registered as VAT payer); - explicit specication of the Subject of performance as per technical background materials of ORBIT MERRET, spol. s r.o., quantity, delivery terms (place and deadline), if pertinent, further specic requirements for the Subject of performance. 3.3. After the receipt of Customer Order the Supplier sends the Customer an Order Conrmation, which is done in writing either by fax or via e-mail. The Supplier is entitled to accept also orders delivered to him after the term of validity of the quotation expired. The Supplier is obligated to send the Order conrmation to the Customer no later than within 3 business days of the date of delivery of the order. 3.4. In case the Customer Order requires a non-standard Subject of performance or the amount exceeds 1000 $, prior to accepting the order, the Supplier may solicit a deposit in the amount agreed-upon in virtue of issued pro-forma invoice. The delivery time stated in the Order Conrmation starts running on the date the Customer pays the deposit. 3.5. In case of larger supplies of the Subject of performance or specic conditions under which the supply is to be realized, or if either of the parties requires so, the parties of the contract may enter into a special agreement on the Subject of performance with reference to the wording of these General terms. 3.6. All additional modications or amendments to the contract (order) have to be made in writing in order to take effect. 4. Delivery terms 4.1. Supplies of the Subject of performance shall be realized according to the Suppliers capacity in the shortest possible term, usually within 2 21 days, in case of special products and more extensive supplies within 3 8 weeks. 4.2. The Supplier will meet the delivery terms provided that all nancial obligations of the Customer from previously realized business deals have been settled. 4.3. The expected term of supply is stated in the Order conrmation. In singular cases the Supplier may prolong the term of supply, however, he shall notify the Customer about the fact without undue delay. 4.4. Delays in delivery terms of our subcontractors, strikes, export or import embargos, war or other events of force majeure relieve the Supplier from the obligation to deliver in term, without the Customer having the right to cancel the order or the right to claim damages (penalty).

4.5. The delivery term is considered fullled when the Subject of performance is delivered to the Customer in the issuing ofce of the Supplier (personal collection), or by appointed employee of the Supplier in the place of delivery or by handover of the Subject of performance to the rst domestic carrier. 4.6. If personal collection by the Customer is arranged for, the delivery term is considered fullled also by notication of the Customer, that the Subject of performance is ready for dispatch. 4.7. Costs related to delivery and place of performance other than the issuance ofce of the Supplier shall be borne by the Customer. 4.8. If the Customer fails to take over the Subject of performance due to reasons on his part, the Customer shall bear the full costs related to repeated delivery. 4.9. If the Customer nds variance with the delivery note, difference in quantity and type of performance, apparent damage of packaging or products, he is obligated to immediately report such fact to the Supplier or the bearer of the consignment, and record it in writing on the delivery note or the delivery note of the forwarding service, however, within 2 business days from delivery at the latest. Later claims of this character will not be taken into account. 5. Orders cancelled by the Customer 5.1. In case of order cancelled after it has been conrmed based on request of the Customer, the Supplier is entitled to bill the Customer 20 % of the price of not taken products. 5.2. If the delivered Subject of performance is returned without justication after the agreedupon term, the Supplier is entitled to charge a contractual penalty in the amount of 50% of the total price of the delivery. 5.3. If the Supplier enforces his right to compensation money or contractual penalty for unjustied return of delivery pursuant to the provisions of par. 5.2., conrmation of the order is cancelled after the set amount is paid. In case of default in payment of this amount the Supplier is entitled to enforce the sanctions pursuant to par. 6.3. 6. Terms of payment 6.1. Unless special terms of payment were arranged for, our invoices are due for payment within 14 days. 6.2. The Supplier is entitled to invoice immediately after the Subject of performance is handed over to the rst public carrier, in case of personal collection after it is realized or after delivery of goods by the Supplier. 6.3. If the Customer fails to pay in due date, he is obligated to pay the Supplier a contractual penalty for delay in the amount of 0,10 % of the billed amount for each day of delay. 6.4. In case of delay in performance of the Customers liabilities the Supplier is not obligated to perform further supplies until the debt is liquidated. In such case, the Customer is not entitled to claim penalty for late performance that ensued from given circumstances. In case of long-term default in performance of liabilities of the Customer, his conrmed orders may be excluded from the records without any compensation. 6.5. The due date is the date by which the amount has to be credited to the account of the Supplier or paid in cash at the Suppliers cash desk. 7. Ownership of the subject of performance 7.7. The right of ownership to the Subject of performance pursuant to these General terms is transferred to the Customer at the moment of payment of the full amount of the purchase price. 8. Guarantee terms 8.1. The Supplier provides a 60 months guarantee for non-defective operation of the Subject of performance, which period starts running on the date of its delivery unless provided for otherwise. 8.2. The Supplier is not responsible for damages caused by incorrect warehousing, wrong outer connexion, outside inuences, in particular electric quantities of inadmissible magnitude, unprofessional assembly, wrong adjustment or attendance. 9. Other provisions 9.1. In cases when the General business terms differ from the terms set out in the submitted Customer order, the provisions contained in the order conrmation hold valid for the purpose of conclusion of the contract. Prospective modications from the Customer have to be approved by the Supplier, otherwise par. 3.6. applies. 9.2. The mode of transportation of the Subject of performance is determined by the Supplier with maximum respect to economical aspects of the transport, unless the Customer has expressly requested otherwise. 9.3. The General business terms are governed by the provisions of the Commercial code. Any disputes related to the application, implementation or interpretation hereof would be solved at the Commercial court in Prague.

m
e

i n

i n s t r u m e n t s

r g b a

OR B I T ME R R E T, sp ol. s r. o. Vodnansk a 675/30 19 8 0 0 P r a ha 9 C z e c h Re p u b l i c t e l . : + 4 2 0 2 81 040 200 f a x . : + 4 2 0 2 81 040 299 e - ma i l : o r b i t @m e r r e t.cz for representative of fices and f ur t h e r i n f o r ma tion se e : w w w. o r b i t . me r r e t.cz

la

i s p l

b
s

s p h a r r g

l a r g e

d i s p

n
u