Vous êtes sur la page 1sur 36

Measurement and control

Digital instruments and measuring transducers

Digital instruments and measuring transducers


M.2 - Digital instruments and measuring transducers
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2-3 Product selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2-5

DC Series
Digital indicator for panel mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2-6

DH series
Digital instruments for panel mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2-9

Royal series
Digital indicator of various parameters for panel or DIN rail mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2-17

DM45 Series
Digital instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2-20

CMM 96
Digital three-phase measurement station for panel mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2-21

Transducers
Narrow profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2-23 High-precision . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2-25 Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . M2-34

M2-2

Digital instruments and measuring transducers

Digital instruments and measuring transducers


CIRCUTOR offers a wide range of fully programmable digital indicators and instruments that can be used to display electrical parameters or define an alarm system associated to an electrical parameter.

M.2
Its general features are as follows:
}} Different sizes 48 x 48, 72 x 72, 96 x 96, 96 x 48 mm }} Multi-scale programmable digital instruments. }} Measurement in true root mean square (TRMS)Measurement of voltage and current with the same unit.Voltmeter, ammeter, wattmeter, varmeter, voltammeter, cosj indicator, THD indicator, process indicators, process control, etc. }} Top performance features in the measurement circuit: yy Accuracy (class 0.1; class 0.2; class 0.5), depending on the type. yy Resolution up to 16 bits. yy Visualization capacity (3, 4, 5 digits) }} Wide range of programmable and multiscale digital instruments to measure AC and DC. }} Module connection options (DH-96 family): yy Relays yy Analogue outputs (010 V, 4..20 mA, etc.) yy Communications with the PC (RS232, RS-485, with protocolos MODBUS RTU, ETHERNET). }} Auxiliary AC and DC power supply }} PowerStudio and PowerStudio SCADA Software to centralise and record the values measured by the computer (equipment with communications) }} Network connection with other RS-485 instruments (CVM power analyzers, etc.) }} Specific instruments for the control of processes (galvanic dips, capacitor bank load analyzers, solar energy, etc.) }} Development in compliance with the current regulations. }} High protection degree (up to IP 65, with accessory)

Definition
In digital instruments, the measurement process provides discontinuous information, expressed in a number with various digits. This is the numerical value of the parameter measured; the numerical indication is presented throughout the time scale with a predetermined frequency. In general, digital instruments have advanced input features when compared to analogue instruments, for example, a higher input impedance in voltage circuits (greater than 2 MW), with a lower consumption of energy and higher accuracy, offering an automatic scale selection and indication of the polarity, which is stored in the instrument and this improves the reliability of the measurement process.CIRCUTOR offers three ranges of digital programmable instruments: DC-B, DH-96 and ROYAL.

M2-3 M2-3

Digital instruments and measuring transducers

Applications
1.- Display on the screen of the numerical value of one or more electrical parameters of a sub-panel, control process or determined unit.

2.- Alarm system: acting on meters, sound and/or light devices, to carry out the protection or notification operations with a relay output .

3.- Control system via software:


yy Voltage control yy Current control yy Frequency control yy Temperature control yy Control of any process signal yy Control of harmonics yy Time control

M2-4

Digital instruments and measuring transducers

Product selection table


Measurement

Page

Single-phase A.C. or D.C.

DC-B

Single-phase A.C. or D.C.

DH96

Single-phase A.C.

Royal

17

Single-phase A.C.

DM45

19

CMM 96

Three-phase A.C.

21

Narrow profile transducers

Single-phase or three-phase according to type

23

High-precision tranducers

Three-phase A.C.

25

M2-5 M2-5

Digital instruments and measuring transducers

DC Series

Digital instruments

Digital indicator for panel mounting

Description
}} Fully programmable: scale, transformer ratio, etc. }} Measurement of V, A, Hz or C. }} Measurement in true root mean square (TRMS), ac types.Excellent quality / price ratio }} Measurement of maximum and minimum values }} Optional relay output, depending on the type

Features
Power supply circuit Frequency Consumption Measurement circuit Resolution Display refresh rate Accuracy No. of samples per cycle (AC) No. of samples per reading (DC) Display Digits Decimal place Range 4 Programmable 0...9999 (ac) / -1999...9999 (dc) - - - - 10 bits 1s 0.5 FE ( 1 digit) 32 / cycle 64 / reading 115 / 230 Vac (10%) 40...70 Hz 4 VA

Application
}} The high luminosity 4-digit digital display indicates the voltage, current, frequency or instantaneous temperature, with the maximum and minimum values of medium and low voltage lines.

Scale excess indicator

Insulation between the input and measurement Test voltage Impulse test Ambient conditions Storage temperature Operating temperature Altitude Build features Box material Degree of protection Weight Standards IEC 1010, IEC 348, IEC 664, EN 50081-1, EN 50082-1 Fitted unit (front panel) Box and terminals ABS V0, grey anthracite IP 54 (IP 65 with front panel protection) IP 20 250 g - 40 ... +70 C -10 ... +65 C 2000 m 3 kV, 50 Hz, 1 min 4 kV (1.2 / 50 s)

M2-6

Digital instruments and measuring transducers

DC series

Digital instruments

Digital indicator for panel mounting


References DC. Voltmeter
Measurement AC Scale 150, 300, 600 Vac Input Direct: 600 V Transformer: Programmable Direct: -200 / +200V Process: 0...10 V -600 / 600 V Direct: -200 mV / +200 mV Shunt: .../60 mV, .../150 mV Size 48 x 48 72 x 72 48 x 48 72 x 72 48 x 48 72 x 72 48 x 48 72 x 72 Type DC 48B Vac DC 72B Vac DC 48B Vdc DC 72B Vdc DC 48B Vdc DC 72B Vdc DC 48B mVdc DC 72B mVdc Code M20210 M20220 M20213 M20223 M20214 M20224 M20217 M20227

DC

10, 50, 200 Vdc

DC

600 Vdc

DC

60, 150, 200 mVdc

DC. Ammeter
Measurement AC AC AC Scale ... / 5 A ... / 5 A 10 A Input Direct: 5 A Transformer: .../5 A Direct: 5 A Transformer: .../5 A Direct: 10 A Direct: -200 mV / +200 mV Process: 0 or 4...20 mV Direct: 10 A Size 48 x 48 72 x 72 72 x 72 48 x 48 72 x 72 48 x 48 72 x 72 48 x 48 72 x 72 Type DC 48B Aac DC 72B Aac DC 72MD Aac (*) DC 48B Aac DC 72B Aac DC 48B Adc DC 72B Adc DC 48B Adc DC 72B Adc Code M20211 M20221 M2022A M20212 M20222 M20215 M20225 M20216 M20226

DC

5,20,200mA

DC

10 A

(*) Output relay available

DC. Frequency meter


Measurement AC Scale Hz < 100,2 dec. Hz > 100, 1 dec. Input 40...600 V Size 48 x 48 72 x 72 Type DC 48B Hz ac DC 72B Hz ac Code M20218 M20228

M2-7 M2-7

Digital instruments and measuring transducers

DC series

Digital instruments

Digital indicator for panel mounting

References DC. Temperature


Measurement Relays C 1 1 Input -200 ... +200 C -200 ... +200 C -200 ... +800 C -200 ... +800 C Size 72 x 72 72 x 72 72 x 72 72 x 72 Type DC 72 TMP22 DC 72 TMP22 - 1R DC 72 TMP28 DC 72 TMP28 - 1R Code M20621 M20623 M20622 M20624

Coding table

M 2 X X X X 0 0 X X
Code Internal Code Standard (230 V) Auxiliary power supply 100 ... 120 Vac 480 ... 500 Vac 18 ... 36 Vdc Current input Standard (.../ 5 A) ... / 1 A 0 1 4 7 0 1

Dimensions

Connections

M2-8

Digital instruments and measuring transducers

DH series

Digital instruments

Digital instruments for panel mounting

Description
}} Digital unit designed to show the programmed value of an electrical variable or process signal on a display, depending on type. Also useful for regulation if used with relay output cards (alarms) }} Fully programmable: scale, transformation ratio, alarm relays, communications, etc. }} Measurement of V, A, Hz and process signal (impulses, weight, temperature, pressure, etc). }} Measurement in true root mean square (TRMS), types in AC. }} Multitude of options with expansion modules }} 4 high luminosity digits }} High accuracy }} Installation in 96 x 48 mm panel }} 4 digit, high luminosity

Features
Power supply circuit Frequency Consumption Measurement circuit Overvoltage (permanent / during 10 s) Overload (permanent / during 10 s) Measurement margin No. of conversions per cycle Display Decimal place Scale excess indicator Insulation Test voltage Impulse test Ambient conditions Storage temperature Operating temperature Altitude Build features Box material Degree of protection Weight Standards In A, C, P types: IEC 1010, IEC 348, IEC 664, VDE 0110, VDE 0435 In other types: IEC 1010, IEC 348, IEC 664, EN 50081-1, EN 50082-1 ABS V0, grey anthracite Box and terminals: IP 20 / Front panel: IP 54 550 g -40 ... +70 C -10 ... +65 C 2000 m 3 kV, 50 Hz, 1 min 4 kV (1.2 / 50 s) 1.2 Un / 2 Un 1.2 In / 5 In 2 .. 120 % 32 Seven 14 mm segments, red Programmable - - - - 230 Vac (-15 ... +20%) 4 VA (without card), 7 VA (with card) 45...65 Hz

Application
}} The high luminosity 4-digit digital display indicates the voltage, current, frequency, etc. and it can be used to define the alarms of the different electrical parameters measured. }} Transducer display of measured parameters to analogue signal for PLCs }} Display and communication of measured data via RS-485 / RS-232 bus for integration into software or PLC.

References DH96. Ammeter or Voltmeter


Measurement DC AC Parameters A or V A or V Range 200 Vdc or 200 mA 600 Vac or ... / 5 A Scale 200 mA or 50,100, 200 V ... / 5 A or 150, 300, 600 V Accuracy 0.2 % ( 1 dig ) 0.5 % ( 1 dig ) Display 4 digits 4 digits Type DH 96 C DH 96 A Code M20411 M20412

M2-9 M2-9

Digital instruments and measuring transducers

Digital instruments for panel mounting


References
DH96. Ammeter
Measurement Parameters Range / Scale Accuracy Display Type Code

DH series

Digital instruments

AC

10 A

0.5 % ( 1 dig)

4 digits

DH 96 A (10 A)

M20413

DH96. Ammeter and voltmeter (with shunt .../60 mV)


Measurement Parameters Range / Scale Programmable: V and A DC A and V Range of V: 1 to 100 V Range of A: With shunt .../60 mV 0.2 % ( 1 dig) 4 digits DH 96 A V M2041C * Accuracy Display Type Code

* Expansion cards are not used

DH96. Measurement station


Measurement Parameters Range Range of V: up to 800 VVdc Range of A: .../60 mV Scale Accuracy Display Type Code

DC

V, A, kW, kWh

Programmable: Selec. V: 100 / 300 / 800 Vdc

0,2 % ( 1 dig. )

4 digits

DH 96 CPM

M20419

DH96. Universal process indicator


Measurement Parameters Range Scale 20 mA, 1 mA, 120 mV, 500 mV, 10 V Accuracy Display Type Code

DC

0,2 % ( 1 dig. )

4 digits

DH 96 P

M20415

DH96. Frequency meter and tachometer


Measurement Parameters Hz, r / min Range / Scale 0.1 ... 20000 Hz Accuracy Display 5 digits Type DH 96 FT Code M20417

DH96. Chonometer and impulse meter


Measurement Parameters S, min, h, No. impulses Range / Scale Programmable to measure time and impulses Accuracy Display 5 digits Type DH 96 CT Code M20418

DH96. Temperature
Measurement Parameters C Range / Scale RTD sensor and thermocouple Accuracy 0.2 % ( 1 dig ) Display 5 digits Type DH 96 TMP Code M2041E

M2-10

Digital instruments and measuring transducers

Digital instruments for panel mounting

DH series

Digital instruments

Dimensions

Connections
DH96 - A / C / P

DH96 - AV / CPM

M2-11 M2-11

Digital instruments and measuring transducers

Digital instruments for panel mounting


Connections
DH96 - FT

DH series

Digital instruments

DH96 - CT

DH96 - TMP

M2-12

Digital instruments and measuring transducers

DH series
Types 2 relays 4 relays

DIN

Digital instruments for panel mounting


COMPATIBILITY WITH DH 96 MODULES C A AV WG CPM P FT CT TPM Code M20421 M20422 M20423 M20425 M20426 M20427 M20428 M20429

2 relays + RS-485 or RS-232 (Modbus/RTU) Analogue output 0 / 4...20 mA Analogue output 0 / 2..10 V RS-232 (Modbus/RTU) RS-485 (Modbus/RTU) Analogue output 0 / 4...20 mA + 2 relays

Module 2 relays
Description Features
Relay Nominal AC Current Maximum voltage Maximum resistive load Insulation resistance ( at 500 Vdc) Contact - coil insulation Contact - contact insulation Mechanical working life (No. of operations) Electrical working life (8 A; 250V ac) (No. of operations) Standards Switched 8A 250 Vac 2000 VA >1000 M 4 kV 1 kV >107 >105 VDE 0435, VDE 0700, VDE 0110, VDE 0106

Module 4 relays
Description Features
Relay Nominal AC Current Maximum voltage Maximum resistive load Insulation resistance ( at 500 Vdc) Contact - coil insulation Contact - contact insulation Mechanical working life (No. of operations) Electrical working life (8 A; 250 V ac) (No. of operations) Standards Simple 5A 250 Vac 750 VA >1000 MW 2 kV 750 Vac >20 x 106 >30 x 103 UL 508, C22.2 no. 14, VDE 0435

M2-13 M2-13

Digital instruments and measuring transducers

DH series

DIN

Digital instruments for panel mounting

Communications module Description


}} 0 to 247 programmable peripherals }} Selection of peripheral number }} (only in RS-485) }} Selection of communication parameters: speed, parity and stop bits

Features
RS-232 Module EDS Protection Communication lines protected against overloads, short-circuit to earth Protected against blockages Communication lines with thermal protection against excessive power dissipation Connection or disconnection from the active network Standards Up to 10 kVac 30 V without damage Yes EIA RS-232 RS-485 Module Up to 2 kVac Yes Yes EIA RS-485

Analogue output module Description


}} Output option: }} 0 20 mA or 4 20 mA }} 0 10 V or 2 10 V }} Range of programmable output

Features
Resolution Maximum load impedance for current outputs Maximum load impedance for voltage outputs Insulation between analogue outputs and the power supply Insulation between analogue and measurement outputs Response time Rippling, in TRMS Temperature coefficient Standards 14 bits 500 500 3 kV 3 kV < 100 ms < 0,5 % 100 ppm / C IEC 1010, IEC 529, IEC 801, EN 50081-2, EN 5002-2

Auxiliary power supply module (DH96P) Description


}} Selectable auxiliary voltage: 5, 10, }} 15 Vdc }} Compatible with all modules }} (except for relays and communications) }} Power supply for 2 and 3 wire sensor }} 0 / 4...20 mA }} Maximum power 1 VA

M2-14

Digital instruments and measuring transducers

DH series

DIN

Digital instruments for panel mounting

Description COMMUNICATIONS Features


}} 0 to 247 programmable peripherals }} Selection of instrument direction (only in RS-485) }} Selection of communication speed: 1200, 2400, 4800, 9600 and 19200 bits/s }} Selection of parity: even, odd or no parity }} Selection of stop bits: 1 or 2

COMMUNICATIONS Features
RS-232 Module EDS Protection Communication lines protected against overloads, short-circuit to earth Communication lines with thermal protection against excessive power dissipation Connection or disconnection from the active network Fully protected against blockages Standards Up to 10 kV 30 V without damage Yes EIA RS-232 RS-485 Module Up to 2 kV Yes Yes EIA RS-485

RELAYS Features
}} Maximum or minimum alarm connection }} Selectable delay to alarm connection and disconnection, programmable between 1 and 9 999 s }} Selectable hysteresis of between 1 and 9999 points }} Alarm interlocking option }} Option of fail-safe relay

RELAY Features
2 Relays Nominal current Maximum voltage Maximum resistive load Insulation resistance ( at 500 Vdc) Contact - coil insulation Contact - contact insulation: 2/4 relays Mechanical working life (No. of operations) Electrical working life (8 A and 250 V) (No. of operations) Standards 8A 250 Vac 2000 VA >1000 4 kV 1 kV 107 > 105 VDE 0435, VDE 0700, VDE 0110, VDE 0106 750 VA Yes 2 kV 750 Vac 20 x 106 >30 x 104 UL 508, C22.2 no. 14, VDE 0435 4 Relays 5A

M2-15 M2-15

Digital instruments and measuring transducers

DH series

DIN

Digital instruments for panel mounting

Communications module + 2 relays

Description ANALOGUE OUTPUT Features


}} Optional output programming: 0...20 mA or 4...20 mA }} Programmable output range

ANALOGUE OUTPUT Features


Resolution Maximum load impedance for current outputs Minimum load impedance for voltage outputs Insulation between analogue outputs and the power supply Insulation between analogue and measurement outputs Response time Rippling, in TRMS Temperature coefficient Standards 14 bits 500 500 3 kV 3 kV < 100 ms < 0,5 % 100 ppm / C IEC 1010, IEC 529, IEC 801, EN 50081-2, EN 50082-2

}} Connection of alarm when maximum or minimum values are reached }} Alarm connection and disconnection delay, programmable between 1 and 9,999 seconds }} Hysteresis can be selected between 9,999 and 9999 points }} Optional alarm interlocking }} Optional fail-safe relay

RELAYS Features

2 RELAY OUTPUT Features


Maximum voltage Maximum resistive load Insulation resistance ( at 500 Vdc) Contact - coil insulation Contact - contact insulation Mechanical working life Electrical working life (8 A and 250 V) Temperature coefficient Standards 250 Vac 750 VA > 1 000 M 2 kV 750 Vac 20 x 106 operations > 30 x 103 operations > 30 x 103 operations UL 508, C22.2, VDE 0435

Coding table

M 2 X X X X 0 0 X X
Code Internal Code Standard (230 V) 100 ... 120 Vac Auxiliary power supply 380 ... 400 Vac 480 ... 500 Vac 18 ... 36 Vdc 36 ... 72 Vdc 40 ... 170 Vdc Current input Standard (.../ 5 A) ... / 1 A 0 1 3 4 7 8 9 0 1

M2-16

Digital instruments and measuring transducers

Royal series

Digital indicator

Digital indicator of various parameters for panel or DIN rail mounting

Description
}} 4 digits, high luminosity }} Measurement in true root mean square (TRMS) }} Measurement in 2 or 4 quadrants (power generated and consumed) }} Valid for single and three-phase systems }} 2 built-in relay outputs }} Measurement of maximum and minimum values }} Fully programmable

Features
ROYAL A4 Power supply circuit Frequency Consumption Measurement circuit Scope Accuracy Overvoltage (permanent / during 10 s) Overload (permanent / during 10 s) Consumption Frequency Display Scale excess indicator Ambient conditions Storage temperature Operating temperature Relative humidity Build features Box material Degree of protection Weight Standards ABS VO Plastic Box and terminals: IP 20 / Front panel: IP 52 170 g IEC 1010, IEC 348, IEC 664, VDE 0435, VDE 0110 -25 ... +70 C 0 ... +50 C -95% to 40 C with no condensation -25 ... +80 C 20 ... 500 Vac ... / 5 A 0.5 % FE 1.2 Un / 2 Un 1.2 In / 5 In 0.25 VA 40 ... 70 Hz 4 digits --- ROYAL A4-P 230 Vac ( 15 %) 40 ... 70 Hz 3 VA ROYAL A3

Application
}} Ideal for industrial environments, thanks to its compact and robust format }} Optional fail-safe operation

References
Measurement AC AC AC Parameters V1n, V2n, V3n or V12, V23, V31 V, A, Hz,W, VA, var, cos, MD, THD V, A, Hz,W, VA, var, cos, MD, THD Input 230 Vp-N / 400 Vp-p ... / 5 A ... / 5 A Digital 2 relays 2 relays 2 relays Size 6 modules 6 modules 96x48x38 Fixing DIN rail DIN rail Panel Type ROYAL A3 ROYAL A4 ROYAL A4-P Code M20332 M20242 M20241

M2-17 M2-17

Digital instruments and measuring transducers

ROYAL series

Digital instruments

Digital indicator of various parameters for panel or DIN rail mounting

Coding table

M 2 X X X X 0 0 X X
Code Internal Code Standard (230 V) 100 ... 120 Vac Auxiliary power supply 380 ... 400 Vac 480 ... 500 Vac 18 ... 36 Vdc 36 ... 72 Vdc 40 ... 170 Vdc Current input Standard (.../ 5 A) ... / 1 A 0 1 3 4 7 8 9 0 1

Dimensions

Connections

M2-18

Digital instruments and measuring transducers

DM45 Series

Digital instruments

Digital indicator for DIN rail mounting

Description
}} Electrical parameter indicator equipment }} Its design enables the installation of the unit on small panels }} It measures voltage, current, frequency and harmonic distortion, depending on the type }} Fully sealed }} Fully programmable alarm relay }} Robust and compact }} Stores maximum and minimum values

Features
DM 45 V Power supply circuit Frequency Consumption Measurement circuit Scope Accuracy Overvoltage (permanent) Overload (permanent) Consumption Frequency 1.05 Un 600 Vac ... / 5 Aac 1.2 In 0.6 VA 10...600 Hz 4 digits with 7 segments, red colour + 4 auxiliary LEDs - 40 ... + 70 C - 20 ... + 50 C 5 ... 95 % non-condensing Self-extinguishing ABS plastic Front panel: IP 54 170 g IEC 1010, IEC 664, IEC/EN 62053-31 IEC61010 30 Aac 10...600 Hz 1.05 Un +/- 0.5 % FE +/- 1 digit DM 45 A DM 45 AD DM 45 F

230 Vac ( 10 %) 40 ... 70 Hz 5 VA

Application
}} Displays one or various electrical parameters of a sub-panel, control process or determined machine }} Alarm system: the unit's internal relay can act on contactors, sound and/or light devices to carry out a protection or warning operation.

Display Ambient conditions Storage temperature Operating temperature Relative humidity Build features Box material Degree of protection Weight Standards Safety standards * Other possible auxiliary power supplies 9..18 Vd.c. / 18...36 Vd.c. / 36...72 Vd.c.

M2-19 M2-19

Digital instruments and measuring transducers

DM45 series

Digital instruments

Digital indicator for DIN rail mounting

References
DM. Voltmeter
Measurement AC Parameters V Input 30..0.600 Vac Relay 1 Type DM45 V Code M20901

DM. Ammeters
Measurement AC AC Parameters A A Input ... / 5 A 30 A Relay 1 1 Type DM45 A DM45 AD Code M20911 M20921

DM. Frequency-meter
Measurement AC Parameters Hz Input 10 ... 600 Hz Relay 1 Type DM45 F Code M20931

DM. Measurement stations


Measurement AC AC Parameters V, A, Hz, THD V, A, Hz, THD Input 600 V / .../5 A / 10...600 Hz 600 V c / 30 A / 10...600 Hz Relay 1 1 Type DM45 CM DM45 CMD Code M20941 M20951

Coding table

M 2 X X X X 0 0 X
Code Auxiliary power supply Internal Code Standard (230 V) 100 ... 115 Vac 18 ... 36 Vdc 0 1 7

Dimensions

Connections

M2-20

Digital instruments and measuring transducers

CMM 96

Digital three-phase measurement station for panel mounting

Description
}} Measures V, A, Hz and unbalances per phase }} Measurement in true root mean square (TRMS) }} Optional expansion of its functions with expansion modules: yy 4 fully programmable relays yy Programmable output range

Features
Power supply circuit Power supply Frequency Consumption Measurement circuit Scope Accuracy Overload (permanent) Consumption Frequency Display Display Colour Display refresh rate Ambient conditions Storage temperature Operating temperature Build features Box material Degree of protection Size Weight Standards IEC 1010, IEC 348, IEC 664, EN 50081-1, EN 50082-1 Self-extinguishing ABS IP 54 front panel 96 x 96 x 87 mm 350 g - 40 ... +70 C - 10 ... +65 C 400 V F-N, 565 V P-P ... / 5 A 0.5 % ( 2 dig) 1.2 In 0.6 VA 35 ... 450 Hz Three 4-digit lines Red, high efficiency 1s 230 Vac (-10 ... +15 %) 35 ... 450 Hz 5 VA

Application
}} Ideal for unbalanced 3 or 4 wire threephase networks for the analysis of electrical parameters. }} Time control with the timer function, (type CH) }} Control of the maximum demand, thanks to the maximeters available per phase (type MD)

M2-21 M2-21

Digital instruments and measuring transducers

CMM 96

Digital three-phase measurement station for panel mounting


References
Measurement AC AC Parameters V,A, Hz and MD per phase V, A, Hz per phase and timer Input 400 Vp-n / 565 V 400 Vp-n / 565 V
p-p

Type CMM96-MD CMM96-CH

Code M20511 M20512

p-p

Expansible modules
Inputs 1 CH input Outputs 4 relays 4 relays Type Module with 4 relays CMM 96 -MD Module with 4 relays CMM 96-CH Code M20522 M20524

Coding table

M 2 X X X X 0 0 X X
Code Auxiliary power supply Insulated inputs Internal Code Standard (230 V) 400 Vac 18 ... 36 Vdc Standard (not insulated) Insulated - ITF 0 3 7 0 1

Dimensions

Connections

M2-22

Digital instruments and measuring transducers

Narrow profile transducers


Electrical parameter transducer in a process signal

Converters

Description
}} Convert voltage, current or frequency in a single-phase system }} Very competitive quality / price ratio }} Ideal for small installations }} Very reliable and robust devices }} Valid for work under demanding conditions

Features
CVE-A Power supply circuit Frequency Consumption Measurement circuit Consumption Frequency Nominal voltage (Un) Nominal current (In) Measurement range Overload (permanent) Overvoltage Analogue output circuit Voltage load impedance Current load impedance Response time Rippling, in TRMS Insulation Test voltage Impulse test Ambient conditions Storage temperature Operating temperature Altitude Build features Box material Degree of protection Weight (g) Standards ABS V0 Box: IP 20 / Front panel: IP 54 190 250 190 IEC 529, IEC 688, IEC 801, EN 50081-1, EN 50082-1 -40 ... +70 C -10 ... +55 C 2000 m 3 kV 4 kV > 500 < 500 < 300 ms < 0,5 % 1000 V 0..0.690 Vac < 0.2 VA 45 ... 65 Hz 5 Aac 5-120 % (*2) 300 % In 1000 V 10..0.600 Vac CCE 40 ... 90 Hz 2.5 VA CFE

230 Vac (-15 ... +20 %) (*1)

Application
}} Systems for the conversion of the electrical parameters of single-phase networks in industrial environments where there are demanding conditions and there is a reduced space. }} Converts voltage, current or frequency into a single-phase system in analogue output or process signal. }} Conversion of electrical parameter signal to process signal for PLCs.

(*1) For other types of power supply, see the coding table (*2) CVE-A-AP i CFE-AP: Measurement range 70-110 %

M2-23 M2-23

Digital instruments and measuring transducers

Narrow profile transducers


References

Converter of electrical parameters into process signals

Standard auxiliary power supply: 230 Vac, 45...65 Hz (*) For non-standard purchase orders, please state the following: 1.Code, 2.Input range, 3.Output range, 4.Auxiliary power supply, 5. In CFE-AP, state the network voltage. (See coding table)
Application Voltmeter Voltmeter (*1) Ammeter Ammeter (*1) Frequency-meter Frequency-meter (Self-powered) 45..0.55 Hz 0...20mA CFE-AP M25521 AC 0.5 % FE Measurement Accuracy Input (*) 300 V 230 V 5A Output (*) 4...20mA 0...20mA 4...20mA 0...20mA 4...20mA Type CVE-A CVE-A-AP CCE-A CCE-A-AP CFE Code M25011 M25021 M25111 M25121 M25511

(*1) Self-powered: does not need an auxiliary power supply. (*) Other inputs, outputs and auxiliary power supplies are offered as an option (See coding table).

Coding table

Dimensions

M 2 X X X X 0 0 X X X X X
Code Internal Code Standard (300 V) CVE-A Voltage 110 V 400 V 500 V 690 V CVE-A-AP Voltage Standard (230 V) 110 V 400 V Standard (5 A) Current 1A 10 A Standard (45...55 Hz) 55...65 Hz 47..0.53 Hz Frequency 45...65 Hz 0..0.100 Hz 380..0.420 Hz 360..0.440 Hz 340..0.460 Hz Standard (4...20 mA) 0...20 mA 0..0.10 V 2..0.10 V Standard (0...20 mA) 0..0.10 V Standard (220...240 V) 380...40 Vac 40/60 Hz 18...36 Vdc Standard (230 V) 110 V 400 V 0 1 2 3 4 0 1 2 0 1 4 0 1 2 3 4 5 6 7 0 1 2 3 0 1 0 3 7 0 0 0 0 1 2

2 - INPUTS

Connections
CVE / CEE CCE

3 - OUTPUTS

CVE-A, CCE-A, CFE CVE-A-AP, CCE-A-AP, CFE-AP Auxiliary power supply Network voltage (CFE-AP)

CFE

M2-24

Digital instruments and measuring transducers

High-precision transducers
Description
}} Wide range of models to measure the main parameters of the electrical network. }} Very reliable and robust devices }} Valid for work under demanding conditions

High-precision

Converter of electrical parameters into process signals

Applications
}} Systems for the conversion of the electrical parameters of single and three-phase networks in industrial environments where there are demanding conditions }} Conversion of electrical parameters to process signal for PLC or displays.

Features
CV-A Power supply circuit Frequency Consumption Measurement circuit Consumption Frequency Nominal voltage (Un) Nominal current (In) Measurement range Overload (permanent) Input impedance Analogue output circuit Voltage load impedance Current load impedance Response time Rippling (TRMS) Insulation Test voltage Impulse test (1, 2...50 ms) Ambient conditions Storage temperature Operating temperature Altitude - 40 ... +70 C -10 ... +55 C 2000 m 3 kV 4 kV 2 kV 3 kV 3 kV 4 kV 2 kV 3 kV < 300 ms < 500 ms < 300 ms > 500 W < 500 W < 100 ms < 0,5 % < 500 ms < 300 ms 0..0.690 Vac 5 A ac 0...150 % Un 300 % 3000 W / V 0..0.3 A ac 0...150 % 500 mA ...10 A 0...20 mA 0...20 kHz 300 %
180 W /V

CW / CY

CCOS / CPF / CFD

CC-WG

CC-D

CC-G

CF

CR2

CT-PT

CC-A

CV-D

220...240 Vac (*1) 40 ... 90 Hz 2.5 VA < 0.2 VA 45 ... 65 Hz 40 ... 600 Vac 0..0.5 A ac 0...200 k 300 % 150 %
1000 W/V

0 mV... 500 V dc -

0...120 % 150 % -

M2-25 M2-25

Digital instruments and measuring transducers

High-precision transducers

Converters

Converter of electrical parameters into process signals


CW / CY CCOS / CPF / CFD

CV-A Build features Box material Weight (g) Ambient conditions 310

CC-WG

CC-D

CC-G

CF

CR2

CT-PT

CC-A

CV-D

ABS VO 540 310 IEC 529, IEC 688, IEC 801, EN 50081-1, EN 50082-1

(*1) For other types of power supply, see the coding table

References
CV-A. AC voltage transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)
Type of input Measurement Accuracy 0.5 % reading 0.2 % reading Alternating voltage AC 0.2 % reading 0.2 % reading 0.2 % reading (*1) Self-powered: does not need an auxiliary power supply 690 Vac Input Digital 0...20 mA 0...20 mA 4...20 mA 0...20 mA 4...20 mA Measurement in true root mean square Measurement in mean values Type of measurement Type CV-A-AP (*1) CV-A CV-A CV-A-RMS CV-A-RMS Code M25041 M25031 M25032 M25051 M25052

CC-A. Alternating current transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)
Type of input Measurement Accuracy 0.2 % reading 0.2 % reading Alternating current AC 0.2 % reading 0.2 % reading 0.2 % reading (*1) Self-powered: does not need an auxiliary power supply 5A Input Digital 0...20 mA 4...20 mA 0...20 mA 0...20 mA 4...20 mA Type CC-A CC-A CC-A-AP (1) CC-A-RMS CC-A-RMS Code M25131 M25132 M25141 M25151 M25152

CV-D. DC Voltage transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)
Type of input DC Voltage Measurement DC Accuracy 0.2 % reading 0.2 % reading Input 10 mV...500 V Digital 0...20 mA 4...20 mA Type CV-D CV-D Code M25061 M25062

M2-26

Digital instruments and measuring transducers

High-precision transducers

Converters

Transducer of electrical parameters into process signals


References
CC-D. Direct current transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)
Type of input DC Voltage Measurement DC Accuracy 0.2 % reading 0.2 % reading Input 500 A ... 10 A Digital 0...20 mA 4...20 mA Type CC-D CC-D Code M25161 M25162

CC-WG. Leakage current transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)
Type of input Leakage current Measurement AC Accuracy 0.2 % reading Input 0..0.3 Aac Digital 4...20 mA Type CC-WG Code M25631

C-F. Frequency transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)
Type of input Frequency Measurement AC Accuracy 0.2 % reading 0.2 % reading Input 40..0.690 V 0...20 kHz Digital 0...20 mA 4...20 mA Type CF CF Code M25531 M25532

CC-G. Galvanic insulation transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz
Type of input Insulation galvanic Measurement Accuracy 0.2 % reading Input 0...20 mA Digital 0...20 mA Type CC-G Code M25610

CT-PT100. Temperature transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)
Type of input Temperature Measurement Accuracy 0.2 % reading 0.2 % reading Input Depending on the sensor Digital 0...20 mA 4...20 mA Type CT-PT100 CT-PT100 Code M25651 M25652

M2-27 M2-27

Digital instruments and measuring transducers

High-precision transducers

Converters

Transducer of electrical parameters into process signals


References
CR-2. Resistance transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply (see coding table)
Type of input Resistance Measurement Accuracy 0.2 % reading 0.2 % reading Input 1...200 k Digital 0...20 mA 4...20 mA Type CR-2 CR-2 Code M25641 M25642

CW. Active power transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply, 5. (phase-phase), 6. In, 7. fn (see coding table)
Type of input Measurement Accuracy System Input Digital 0...20 mA 4...20 mA 0...20 mA 300 V.../5 A 4...20 mA 0...20 mA 4...20 mA 0...20 mA 4...20 mA Type CW-M CW-M CW-TE CW-TE CW-TA CW-TA CW-TAN CW-TAN Code M25211 M25212 M25221 M25222 M25231 M25232 M25241 M25242

Single-phase Balanced three-phase AC 0.5 % reading Unbalanced three-phase ARON (3 wires) Unbalanced three-phase ARON (4 wires)

Active power

CY. Reactive energy transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply, 5. (phase-phase), 6. In, 7. fn (see coding table)
Type of input Measurement Accuracy System Input Digital 0...20 mA 4...20 mA 0...20 mA 300 V.../5 A 4...20 mA 0...20 mA 4...20 mA 0...20 mA 4...20 mA Type CY-M CY-M CY-TE CY-TE CY-TA CY-TA CY-TAN CY-TAN Code M25251 M25252 M25261 M25262 M25271 M25272 M25281 M25282

Single-phase Balanced three-phase AC 0.5 % reading Unbalanced three-phase ARON (3 wires) Unbalanced three-phase ARON (4 wires)

Power factor

M2-28

Digital instruments and measuring transducers

High-precision transducers

Converters

Transducer of electrical parameters into process signals


References
CPF. Power factor transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply, 5. (phase-phase), 6. In, 7. fn (see coding table)
Type of input Measurement Accuracy System Input Digital 0...20 mA 4...20 mA 300 V.../5 A 0...20 mA 4...20 mA 0...20 mA 4...20 mA Type CPF-M CPF-M CPF-TE CPF-TE CPF-TEN CPF-TEN Code M25311 M25312 M25321 M25322 M25331 M25332

Single-phase Unbalanced three-phase ARON (3 wires) Unbalanced three-phase ARON (4 wires)

Power factor

AC

0.5 % reading

CCOS. cos j transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply, 5. (phase-phase), 6. In, 7. fn (see coding table)
Type of input Measurement Accuracy System Input Digital 0...20 mA 4...20 mA 300 V.../5 A 0...20 mA 4...20 mA 0...20 mA 4...20 mA Type CCOS-M CCOS-M CCOS-TE CCOS-TE CCOS-TEN CCOS-TEN Code M25341 M25342 M25351 M25352 M25361 M25362

Single-phase Unbalanced three-phase ARON (3 wires) Unbalanced three-phase ARON (4 wires)

cos

AC

0.5 % reading

CFD. Current distortion factor transducer Standard auxiliary power supply: 230 Vac, 40...90 Hz For non-standard purchase orders, please state the following: 1. Code, 2. Input range, 3. Output range, 4. Auxiliary power supply, 5. (phase-phase), 6. In, 7. fn (see coding table)
Type of input Measurement Accuracy 0.2 % reading 0.2 % reading 0.2 % reading 0.2 % reading System Input Digital Type Code

0...20 mA 4...20 mA

CFD-THD CFD-THD CFD-D CFD-D

M25411 M25412 M25421 M25422

Distortion factor of I

AC

5A 0...20 mA 4...20 mA

M2-29 M2-29

Digital instruments and measuring transducers

High-precision transducers

Converters

Transducer of electrical parameters into process signals

Dimensions
CV-A, CV-D, CC-A, CC-D, CR2

Connections
CV-A CV-D CC-A

CC-D

CR2

M2-30

Digital instruments and measuring transducers

High-precision transducers

Converters

Transducer of electrical parameters into process signals


Dimensions
CW, CY, CPF

Connections CW
CW-TA CW-TAN CW-TE

CY
CY-TE CY-TA CY-TAN

CPF
CPF-TE CPF-TEN CPF-M

M2-31 M2-31

Digital instruments and measuring transducers

High-precision transducers

Converters

Transducer of electrical parameters into process signals

Dimensions
CCOS / CFD

Connections
CCOS CFD-THD / CFD-D

Dimensions
CT-PT100

Connections
CT-PT100

M2-32

Digital instruments and measuring transducers

High-precision transducers

Converters

Coding table

Transducer of electrical parameters into process signals

M 2 X X X X 0 0 X X X
Code Internal Code Standard (300 V) Alternating voltage 110 V 400 V 500 V 690 V Alternating current Standard (5 A) 1A 10 A Standard (10 V) 60 mV DC Voltage 1V 100 V 500 V Standard (20 mA) Direct current 200 mA 1A 10 A Standard (300 V, .../ 5 A) 110 V, .../5 A 0 1 2 3 4 0 1 4 0 1 2 3 4 0 1 2 3 0 1 2 3 4 5 6 7 8 9 0 1 0 0 1 2 3 0 1 0 1 2 3 4 0 1 2 3 4 5 6 7 8 0 2 0 3 7 9

INPUTS

400 V, .../5 A Power, power factor, cos j (V, A) 500 V, .../5 A 600 V, .../5 A 300 V, .../1 A 110 V, .../1 A 400 V, .../1 A 500 V, .../1 A 600 V, .../1 A Distortion I Standard (5 A) 1A Standard ( 20 ) Resistance 200 2 k 20 k Temperature Standard (-200...+200 C) -200 ... +800 C Standard (45...55 Hz) 55...65 Hz Frequency 47..0.53 Hz 57...63 Hz 0..0.100 Hz Standard (0...20 mA) 0..0.1 mA 0..0.10 mA 2V Outputs 1, 3 5V 0..0.10 V -20...0...20 mA -10...0...10 V -5...0..0.5 V Outputs 2 Auxiliary power supply Standard (4...20 mA) 2..0.10 V

Leakage current, Universal process

OUTPUTS

Standard (220...240 V) 380...40 Vac 40/60 Hz 18...36 Vdc 90..0.140 Vdc

M2-33 M2-33

Digital instruments and measuring transducers

accessories
PowerStudio
Description
Software. See M.9 Catalogue Code M90211

Accessory

PowerStudio Scada
Description
Software. HASP USB License See catalogue M.9 Code M90231

Accessory

Front Panel Adaptors


Description
IP 65. Front panel protector 48 x 96 mm Code M29921

Accessory

Description
}} Front panel adaptor 48 x 48 to 72 x 72 mm Code M29911 }} Front panel adaptor 48 x 48 to 96 x 96 mm Code M29912 }} Front panel adaptor 72 x 72 to 96 x 96 mm Code M29914

Description
}} Front panel adaptor 48 x 96 to 96 x 96 mm Code M29913

M2-34

Digital instruments and measuring transducers

M2-35 M2-35

Digital instruments and measuring transducers

+ information: central@circutor.es

www.circutor.com

CIRCUTOR, SA - Vial Sant Jordi, s/n 08232 Viladecavalls (Barcelona) Spain Tel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 central@circutor.es

CIRCUTOR, SA reserves the right to change the content of this catalogue without prior warning

Designed by: Comunication dpt. - CIRCUTOR, SA