Vous êtes sur la page 1sur 112

Hospital communications systems. systems.

Produc Product Catalog Catalogue atalogue. ue.

VISOCALL PLUS

Foreword

Foreword
Schrack Seconet AG has been known as an innovative company since it was founded. In all our product divisions we offer solutions that are in line with market requirements, which are highly valued by our customers and partners far beyond our national boundaries. We constantly attempt to address the constantly and rapidly growing demands of the market with our products. We therefore offer you, as a company specialising in security systems, a wide range of different systems and devices, especially with regard to communications systems. All product families are closed and autonomously functioning systems, which are also able to communicate with one another by means of the available systems interfaces. Furthermore, we are also able to rapidly and reliably connect to foreign systems, if particular requirements stipulate this. Schrack Seconet AG is a guarantee for security and quality! You can rely on us to also rise to challenges in the future too, so that current and future systems and platforms can also be offered in line with market requirements and offering user friendliness. Schrack Seconet AG wishes you every success.

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Table of Contents

Table of Contents
Table of Contents Page

Foreword................................................................................. 2 Table of Contents .................................................................... 3 VISOCALL PLUS General................................................................................... 6 SystemDescription ................................................................... 7


1 2 3 4 Characteristic System Properties.......................................................................................7 The types of system .......................................................................................................10 The system functions......................................................................................................12 System devices ..............................................................................................................19

Datasheets ............................................................................ 22
1 2 3 4 5 6 7 8 9 Connection Devices .......................................................................................................22 Patient handsets and Accessories ...................................................................................25 Call and cancel button combinations .............................................................................29 Signal lamps .................................................................................................................32 Room terminals .............................................................................................................35 Mini terminal.................................................................................................................37 Bus interface .................................................................................................................39 Miscellaneous................................................................................................................41 Text terminal .................................................................................................................44

10 Ward Terminal ..............................................................................................................46 11 Control panel/Ward control panel .................................................................................48 12 Interfaces ......................................................................................................................51 13 TV devices and accessories ............................................................................................53 14 Power supplies ..............................................................................................................62 15 Installation accessories ..................................................................................................66

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Table of Contents

VISOTAX PLUS General................................................................................. 72 System Description ................................................................ 73


1 2 3 4 General.........................................................................................................................73 Hardware......................................................................................................................77 The Software .................................................................................................................80 The Components ...........................................................................................................82

Datasheets ............................................................................ 84
1 2 3 4 5 6 Hardware......................................................................................................................84 Software Modules..........................................................................................................87 Hardware Cash Register ................................................................................................90 Software Cash Register ..................................................................................................93 TV Interfaces .................................................................................................................94 Accessories....................................................................................................................97

VISO-OPT PLUS System Description ................................................................ 99


1 2 3 Characteristic System Properties.....................................................................................99 The types of system .....................................................................................................101 The system functions....................................................................................................101

Datasheets .......................................................................... 102


1 2 3 1 Terminals ....................................................................................................................102 Connectable components ............................................................................................103 Power supply and Transformer.....................................................................................105 Characteristic System Properties...................................................................................108

VISOCALL FUNK Datasheets .......................................................................... 109


1 Radio components.......................................................................................................109

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

VISOCALL PLUS

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

General

General
Internal messaging systems are an absolute necessity in hospitals. Everyday life in the hospital is marked by staff stress and time pressure. Nonetheless, every patient wants to see the best possible conditions for his care. Hence, the great importance of having optimal access to information throughout the entire hospital. Nurse call systems assist in this task. They enable rapid contact between patients and nursing staff, as well as between nursing-staff members. Every patient is able to reach "his" nurse, and every nursing-staff member can call additional staff members and the doctor. Light signals in the place from where the call has originated and voice circuit connections ensure optimal communications. However, every hospital is an individual entity. Various criteria for evaluation must also be observed, such as the fact that demands, opinions and necessities can change. VISOCALL PLUS offers optimal solutions for this problematic area: State of the art technology allows a standard installation for every forms of patient care. Room terminals and patient handsets with autarchic single chip processors render controlling processes from above superfluous, simultaneously acting as switchboards for data and docking with other intelligent units. Multiplex sound-control as well as new hardware and software components offer further advantages as well as allowing the integration of additional systems. Monitor systems with colour graphical displays with automatic sector overlays with their many buttons and lamps make it possible to dispense with voluminous switchboard queries.

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

SystemDescription
1 Characteristic System Properties

1.1 Standards
VISOCALL PLUS complies with the current standards and regulations: DIN-VDE 0834 - Call systems in hospitals, care homes and similar establishments, valid from 1 April 2000 DIN-VDE 0834 / Part 1 - Device specifications, installation and operation, valid from 1 April 2000 DIN-VDE 0834 / Part 2 - Environmental conditions and electromagnetic compatibility, valid from 1 April 2000 Provision of electricity in accordance with EN60950, EN61000-4-2 to -4-6 as well as EN61000-3-2 and EN55011 (Class B)

as well as all standards and regulations referred to in these standards. All VISOCALL PLUS system components conform to environmental class I, whilst all components which are installed in sanitary units, bathrooms etc. conform to environmental class II. In accordance with VDE0834 part 2 this means: Environmental class I: +5C to +40C *) with an relative air humidity of up to a maximum of 85% Environmental class II: +5C to +40C with an relative air humidity of up to a maximum of 95% *) +55C when installed in medical supply units When planning and constructing nurse call systems the currently applicable regional regulations must also be observed from the installation to the operation of call systems in hospitals, old peoples homes and similar establishments. Many of the VISOCALL PLUS systems properties considerably exceed these requirements.

1.2 Maximum Security


Complete system failure impossible Every terminal possesses an autarchic single chip processor containing comprehensive software. System-related complete system failures can therefore be ruled out. Self monitoring Self-monitoring of the computers and data and voice circuits ensures that faults are displayed and that safety features are triggered. Storage of data In the event of a power-cut all pending information remains saved, and is then automatically restored when the power returns. The minimum permitted storage period in accordance with DIN standards is 15 seconds. VISOCALL PLUS saves the pending information permanently and can not lose it during a power-cut. Safety features Automatic call forwarding and automated monitoring processes at regular intervals prevents the blocking and disconnection of call and speech circuits. LEDs and security against short circuits Controllers use LEDs and terminals contain short circuit-proof lamp outputs.

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

1.3 Basic Installation


Infinitely variable system construction Each room terminal forms an independent system with the devices present in rooms Two terminals on a bus connection already form a functional system with call forwarding, intercom system etc. Any system can be created by connecting room terminals to one another and can be universally used with system queries. Identical Room Terminals Room terminals are identical in all rooms; however, different functions are still possible. Terminals with a display can indicate the type of call and location of the call straightaway. Safe planning A Standard Installation allows the realisation of every possible type of system, and it is always possible to make changes. System cables are available for the wiring system, and terminal sockets simultaneously act as room splitters.

1.4 Optimal concept for devices


Components which have been thoroughly thought out down to the finest details are a hallmark of the VISOCALL PLUS device concept: Connection Devices to be built into countersunk switchboxes or installation units for hospital rooms (service ducts). Patient handsets Various versions available - the optimal solution for every use. Call and cancel buttons buttons For toilets, bathrooms and day rooms etc. Signal lamps For signalling on a room, area and ward-related basis, also available on request using LED technology. Room terminals As autarchic communications and data centres, with integrated speech communication, available in several forms, all with a membrane keypad. Mini terminals To allow additional rooms to be incorporated with selective functions without speech functions. ELAC radio controller Connected to room terminals to activate radio reception Bus interface To control ward signal lamps and as interfaces to other systems Text displays For quick, comprehensive and clear signalling. Ward Terminal With a VGA colour display and a few interactive buttons. Control Panel Colour graphical monitor system for an optional overview and easy operation. Serial interfaces For communication with other systems
8 product catalogue V1.2 FC38502E-A

VISOCALL PLUS Power supplies For supplying power to the ward or a particular sector (24V=). Accessories Switchboxes and cases, soffit lamps, special system cabling etc.

SystemDescription

1.5 Realisation of all types of system


Just by connecting the necessary query locations to the standard installation it is possible to realise: Decentralised systems or/and Centralised systems or/and Combination systems

It is possible to change from one type of system to another at any time. The room terminals allow the formation of Communication Islands For bathrooms and treatment wards with an self-contained functional flow within every type of system.

1.6 Combination with other systems


VISOCALL PLUS can work in combination with a wide range of other systems: In combination with ELAC and TV systems In combination with Schrack-Seconets automatic billing system In combination with lighting controls In combination with the wireless paging system In combination with DECT systems In combination with the IT system In combination with the fire alarm system In combination with the in-house IT system In combination with the system for disoriented persons.

VISOCALL PLUS is the symbiosis of the complex requirements placed on future looking communications systems in the healthcare sector, the highest level of security and optimal operating comfort. All these features are bundled together with state-of-the-art technology and a cutting edge design.

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

The types of system

VISOCALL PLUS makes it possible to implement any type of system in accordance with DIN 41050 Part 1 whilst additionally offering practice-specific customisability. Global measures can also be implemented for decentralised systems (using possible extensions). There are no limitations to the number of possibilities for extending VISOCALL PLUS functions and configurations. All important system devices contain single chip processors with comprehensive software, which permits the required function. Any system configuration is possible, based upon a standard installation of the system, by simply connecting room terminals, ward terminals and control panels. If all types of connector are present, then it is possible to use or remove any type of device at any time. Devices automatically recognise the current status of the system.

2.1 Decentralised systems


Decentralised nurse call communication systems consider each ward as an individual sector, in which the systemrelated interests of patient care by nursing staff in the ward are detected directly. All calls by patients reach nursing staff immediately, and are followed up by the nursing staff either via using the systems speech circuits or by them going to the place where the call originated. Each ward is equipped with a ward terminal, from which the current functional status of the system can be ascertained, and can be acted upon accordingly. Room terminals offer assistance in all important areas, and each of these can be used as a sub-terminal. Decentralised stations can be combined practically for operation with reduced staff levels. The duty area of members of the nursing staff is then no longer linked to a specific sector; functions (including call-forwarding und speech circuits) cover all interconnected wards and can be accessed at every room terminal and ward terminal. The interconnection of groups can be activated and deactivated again at any time. In critical cases, the interconnection process occurs automatically.

2.2 Centralised Systems


Centralised nurse call communications systems possess a control panel covering all wards in the building. All calls are displayed on the control panel and are monitored by a control centre operator. The tasks to be carried out in the various wards are then transmitted to the nursing staff members working in that area via the systems speech circuits. Communication with nursing staff and patients is carried out via the room terminals or patient handsets. Other sectors can also be integrated in to the functions section of the control panel. Any ward can be detached from the control panel at any time and then function in a decentralised manner. Speech transmission in every detached ward remains possible, even when the are doesnt contain any ward terminals. Equally, each decentralised ward can also be reconnected to the control panel. If the control panel is unmanned, then all wards function as decentralised wards. The type of system can be changed at the push of a button, or, in critical instances, automatically.

10

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

2.3 Combination systems


Combination systems make it possible to selectively use both types of care systems listed above. All types of system can be used with the corresponding query locations. Activated configurations can function separately from one another or in harmony with one another. It is possible to change from one type of system to another at the press of a button or (in critical instances) automatically. Combination systems offer the advantages of both decentralised and centralised forms. The (decentralised) wards that are no longer being operating centrally can also be combined with one another. It is therefore possible, for example, to have all wards attached to the control panel by day, whilst each ward is decentralised during the night. Or, all wards can function as decentralised ones, whilst a control panel is activated for the centralised night watch duty, on which checks or combining of functions can be carried out.

2.4 Communication Islands


It is possible to create independent communications islands without any specific measures necessary by connecting room terminals with call buttons and cancel buttons. Communication islands function either with or without speech connections and can for example be used for therapy wards. If need be, then these communications islands can also work in collaboration with other wards.

2.5 Group Care


In certain cases it is necessary to define care groups within communication islands. Different nursing staff members are responsible for different patient groups. Calls made in a care group remain within the group and are then also treated within the group. In the event of a call not be answered in time, then the automatic override function becomes effective and diverts the call(s). Up to 7 care groups per ward can be assigned, either within their own ward or in multiple wards.

11

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

The system functions

VISOCALL PLUS doesnt require superordinated controls neither for functions, nor for speech circuits or system configuration. All system functions are stored, ready-for-use, in the microcomputers of the autarchic room terminals and query locations. Each room terminal recognises the attached system components (e.g. patient handsets, call buttons, signal lamps etc.) by means of programming and signals all activities within the area. Every ward terminal or every control panel automatically recognises the accompanying room terminals and ward terminals and displays the functions for the entire area. System devices communicate with one another via the bus circuits, whilst making the relevant decisions about functions autarchically. Every important function (doctor call, diagnostic call, emergency call etc.) can be monitored via the system interface and can be transferred to other systems or communications processes.

The following functions are as standard. Additional property-specific customisations can be carried out using the systems software structure. Light signals, call signs and signalling intervals etc. are in accordance with DIN and VDE requirements. In the explanation of functions and system parts, the terms mentioned therein are also observed.

3.1 Presence indicator


In which rooms nursing staff members are to be found is displayed by light signals in the corridor and in the query locations. Presence is marked via the presence keys on the room terminals, and is displayed on the presence key that has been pressed being continuously lit, as well as being displayed on room signal lamps in the corridor, and the relevant room indicator lamp on the ward terminal or the control panel. Up to three possible presence indications are possible - namely for: Nurses Helper nurses Doctors green yellow orange

Calls and reminders are also cancelled, by pressing the presence buttons, and emergency calls, doctor calls, calls forwarded and secondary queries initiated by the same process.

3.2 Telephone Call


This call originates from the nurses room telephone, and is automatically triggered if the receiver is not picked up when a phone call is received. The call is intended for the nurse and can reach her wherever she is within the ward. This call can not be queried; it is cancelled once the nurse picks up the phone receiver in the nurse's room, or if the caller has already hung up earlier. This call is signalled by a continuous red light and as an audio signal in the form of a slow ring tone. This call is suppressed in centralised systems.

3.3 Bed call with speech connection


This call is made by the patient from his/her bed. It is intended for the nurse and can be answered by her at room terminals, or at the ward terminal or at the control panel, and remotely cancelled. This call is signalled by a continuous red light and as an audio signal in the form of a slow ring tone.

12

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

3.4 Enhanced patient call


This call is made by the patient from his/her bed. It is intended for the nurse and can be answered by her at room terminals, or at the ward terminal or at the control panel, and remotely cancelled. This call is signalled by a continuous red light and as an audio signal in the form of a slow ring tone. This call is first incorporated in version 2.1 of the software. It has a higher priority than the normal bed call.

3.5 Removal call


This call is automatically made, if the connection plug of a patient handset is pulled out of its connection device. The removal call can not be queried, is made to the nurse and is followed up by her immediately; plugging the device in again will restore the communication for the patient. The call is signalled by a continuous light and an audio signal in the form of a slow ringing tone, and as an engaged tone after the call has been answered.

3.6 Room call with speech connection


This call is made by the patient from the room terminal. It is intended for the nurse and can be answered by her at room terminals, or at the ward terminal or at the control panel, and cancelled remotely. This is signalled by a continuous red light and as an audio signal in the form of a slow ringing tone.

3.7 Bathroom or VC call from a rooms sanitary unit


This call is made by the patient from a room's sanitary unit (toilet, shower, etc.). The call can not be queried and is followed up by the nurse directly. This is signalled by a continuous white light and as an audio signal in the form of a slow ringing tone.

3.8 Bath or WC call from a separate sanitary unit


This call is made by the patient from a separate sanitary unit (toilet, toilet block, ward bathroom). The call can not be queried and is followed up by the nurse directly. This is signalled by continuous white and red lights and as an audio signal in the form of a slow ringing tone.

3.9 The Bathroom of WC Emergency Call from the rooms sanitary unit or from a separate sanitary unit
This call is made from the separate sanitary unit (toilet, toilet block or ward bathroom) by the nurse whose presence has been marked. This call can not be queried and is first incorporated in version 2.1 of the software.

3.10 Bed emergency call with speech connection


This call is triggered by the nurse, if the assistance of a second nurse is required at a patient's bed. The call can be made where presence has been indicated and can be answered by the second nurse at room terminals, or at the ward terminal or at the control panel, and cancelled remotely. This call is signalled by a blinking red light and as an audio signal in the form of a quick ringing tone.

3.11 Room emergency call with speech connection


This call is made by a nurse from the room terminal to a second nurse. The call is made where presence is indicated and can be answered by the second nurse at any other room terminal, or at the ward terminal or at the control panel, and cancelled remotely. This call is signalled by a blinking red light and as an audio signal in the form of a quick ringing tone.

13

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

3.12 The Diagnostic Call


This call is automatically triggered by a monitoring device at the patients bed. The call can not be queried and is followed up by the nurse directly. This call is signalled by a blinking red light and as an audio signal in the form of a quick ringing tone.

3.13 Doctor call with speech connection


This call is made by a nurse from the room terminal to a doctor. The call can be made where presence has been indicated and can be answered by the doctor at other room terminals, or at the ward terminal or at the control panel, and cancelled remotely. This is signalled by a blinking orange light and as an audio signal in the form of a quick ringing tone.

3.14 Doctor call via pager system


A doctor call as per point 11 can automatically activate the pager system. This may be done for an area or as a group call. The call is displayed by a blinking orange light as a signal on the doctors pager.

3.15 Doctor call via a DECT system


When a doctor call, as described in point 13, is not answered in VISOCALL PLUS, it can automatically be forwarded to a DECT system. The may be done for an area or as a group call. When the call is picked up, a speech connection will be made with the place from where the call originated. The call is displayed by a blinking orange light and by signals to the doctors DECT devices.

3.16 The Priority scheme


The various types of calls are placed in a priority hierarchy. This hierarchy ensures that in the event of different calls happening simultaneously, that the nursing staff answering the calls are directed to the highest ranked of the calls. Nursing staff are able to take action manually at the ward terminal and the control panel and to query the call that is more important for them. Call prioritisation is therefore circumvented. This however must be done consciously by pressing a button.

3.17 Answering a call at at the ward terminal, at the control panel


Presence and call indicators as well as call queries are carried out by room, with diversion through to patient handsets happening automatically. The nurse is able to accept one call after another (using free room selection or automated querying). Each call is instantly marked as being queryable or not queryable. Text displayed on the screen optimises the operation process. Queryable calls: After the call has been queried, a speech connection is made to the caller, which is displayed by means of an attention indicator to both parties in the conversation. Additionally, the type of call and location of the call are also displayed. After the conversation has been ended, each call can be remotely cancelled or be replaced by a reminder. Non Queryable calls: They are also immediately displayed according to type of call and location of call after having been received. The call is acknowledged at the place where the call was triggered, which can additionally be ascertained by means of a reminder. Appearance on the display: Up to 4 of all the currently pending calls can be displayed simultaneously on the ward terminal. It is possible to view all the calls using the scroll function. On the right hand side next to the call symbol the type of call and call location is displayed as plain text.

3.18 Call answering from the room terminals


14 product catalogue V1.2 FC38502E-A

VISOCALL PLUS

SystemDescription

Room terminals with presence marked are automatically activated in decentralised systems for call diversion and secondary queries. As a result the nurse can be reached in every important room in the ward, and is therefore informed of existing calls. Linking to the network happens according to the priority hierarchy, and each call is immediately recognised as being queryable or non-queryable. Queryable Queryable calls: When a queryable call is accepted, a speech connection to the person making the call is made. After the conversation has been ended, each call can be remotely cancelled or be replaced by a reminder. Non Queryable calls: They can be recognised as such straightaway and can only be acknowledged from the location where the call was triggered. Appearance on the display: The type of call and location of the call is displayed as text on room terminals with a display. Additional calls made during the conversation are signalled by a changing display. Note about points 3.17 and 3.18: Queryable calls can naturally also be reacted to directly (without the prior conversation process) as non-queryable calls, and can be acknowledged in the room the call came from by pressing the corresponding presence key on the room terminal (or the separate cancel button of e.g. the sanitary unit).

3.19 Reminders
The purpose of a reminder is to indicate (mark, identify) rooms, which are to be visited by a member of the nursing staff as a follow-up to a call. A reminder is generally activated by nursing staff themselves, if there is no reply from the person making the call when querying a call, or if there is no speech connection for a call, or if there is an engaged tone, or if other calls are to be queried before going to the location of the call or if calls are delegated to other nursing staff members. Calls with reminders can be repeated and queried several times. It is possible to activate up to three reminders either at room terminals and at the ward terminal or at the control panel - for Nurses Helper nurses Doctors green yellow orange

The reminder has to be cancelled in a marked room.

3.20 Call to a room


The nurse at the ward terminal or the control panel can address every room in the same area via the room terminals. There is a mute function at terminals where presence has not been marked, which can be lifted by replying from this terminal. The call to a room is indicated on the terminal being called.

3.21 Call to a bed


The nurse at the ward terminal or the control panel can address every bed in the same area via the patient handsets. The call is signalled on the patient handset, and the existing eavesdropping mute function is removed by being called back by the device being called.

15

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

3.22 Ward announcement (collective announcement)


The nurse at the ward terminal or the control panel can make group announcements via the room terminals, which are signalled by calling. Announcements can be made based on presence or generally. Presence related announcements only go to the room terminals of the ward being called, where nurses have marked their presence. General announcements include all room terminals inclusive of the patient handsets used within those rooms in the selected ward, regardless of whether presence has been indicated or not. It is also possible to make additional collective announcements to all rooms in the building from the control panel. These announcements can also be activated dependent upon presence or generally.

3.23 Group Interconnection


This allows the formation of care areas, which consist of two or more wards. The opportunity to query or divert each individual call is now increased (in the priority scheme) to encompass all ward and room terminals in the whole area. Additional group signal lights display in which wards there are calls or reminders. Interconnection of groups can be carried out separately for: calls for nurses and calls for doctors,

since doctors generally have different duty areas. Ward terminals and room terminals with a display also display the ward number when the call is sent.

3.24 Group Care


Group care, as opposed to interconnection of groups, makes it possible to assign rooms within a ward or even across several wards into logical groups. This can either be done as a one-off event or during normal system operation. Up to 7 different care groups are permitted per ward. Calls from a care group remain exclusively within this group as long as they are answered promptly. If this is not the case in an individual instance, then the call is automatically forwarded and received by the ward terminal or the control panel.

3.25 Centralisation
Centralisation blocks call forwarding and the ability to query the call at room terminals across the whole ward. All calls from the ward are only displayed at the ward terminal and can only be queried from here. Centralisation is said to have occurred, if, for example, all calls are queried by a nurse at the ward terminal, although calls will be delegated to only nursing staff in the ward for being dealt with. Such a system is as a rule however only usual in CENTRALISED SYSTEMS.

3.26 The Ward Call


This call is made by a nurse from the ward terminal or the control panel. It is intended for a second nurse in the relevant part of the ward, and can be queried and remotely cancelled by this nurse at the room terminals or be replaced by a reminder.

3.27 Testing and service functions


Important components and connections are automatically monitored. Errors are reported on the ward terminal or in the control panel, according to their cause, as Ausfall - Failure or Strung - Fault, and unaffected devices continue to function normally. Test functions which can be carried out at any time, for LEDs, lamps and audible alarms, allowing the problem-free testing of these system components.

16

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

3.28 Automatic safety functions


Automatic and time-controlled monitoring processes prevent signal and speech circuits from being disruptively affected or blocked by user errors as well as preventing calls from being lost in the event of a power outage. Regulated call forwarding The querying of a call stops it from being displayed at other query locations, although new calls are immediately displayed again. A conversation can neither be influenced nor terminated from another location. Automatic call forwarding Calls which are not answered within a certain time in a ward are forwarded to the neighbouring ward, and can be queried from there (with automatic interconnection of groups in critical cases). This is also the case for calls within a defined nursing group. Automatic call termination To avoid speech circuits getting blocked, patient calls are terminated after a specific time period. This is also the case if, after having finished the conversation, call cancellation has been forgotten. Data storage The system computer saves its current information status for at least 15 minutes during a power failure, and then saves it again after the power outage. If there is a power cut during a conversation, then the affected room is marked with a reminder when the power returns.

3.29 Switching of lighting circuits


Every patient handset contains two light switches with faint guide lighting. They are used for the indirect switching on and off of two lighting circuits (e.g. a reading light and reduced room lighting).

3.30 Receiving audio programmes


Room terminals and patient handsets also allow the reception of six radio programs via the internal ELAC system. In addition to the 6 radio programs, sound for television programs can also be separately transmitted to every bed. If patient calls are being connected and taking place, then the selected program is automatically switched off on the affected devices. All connection devices, apart from parts SVM and SVM-K support the additional connection of headphones, with sound reception being diverted from the patient handset to headphones when the headphones are plugged in. Also using room terminals in nurses rooms and day rooms etc. for ELAC reception too makes it possible to dispense with separate speakers. A separate amplifier in room terminals and patient handsets substantially reduces the workload of the ELAC control centres.

3.31 Additional Programs


The system software also makes the following additional functions possible from every room terminal: Group announcements: Members of nursing staff can make presence-related or general group announcements from any room terminal in the ward. Incorporation of additional sanitary units: The mini-terminals that are specifically designed for sanitary units can be used, with each mini-terminal enabling selective displays for the included rooms. This information is available throughout the entire ward.

17

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

3.32 The connection to the inin-house IT control centre


Data can be obtained via the control interface and sent for system surveillance purposes or logging of calls and their completion to the in-house IT control centre.

18

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

System devices

Using the aforementioned system devices it is possible, in practice, to create any type of system imaginable. Functions are automatically adapted using the devices in-built software. The system devices correspond to the relevant VDE and DIN standards. The devices use screw clips, screw-free clips or ribbon cable connectors for the wiring connections. Every system device contains all the components and software modules which are required for all possible system-related uses; an initial supply of LEDs is also included. Boxes for counter-sinking, materials for use in the installation process, light bulbs, cabling etc. are all listed separately in section 11. Accessories and should be acquired separately. Switchboxes and double switchboxes for use in installation in cavity walls and concealed installation are as standard (as described in section 14 Accessories) and can also be obtained elsewhere. The same is also true for the various wiring materials. Some system devices are delivered as individual pieces for economic reasons and installation purposes. These parts for shipping are listed alongside the relevant devices, including their order numbers. Precise advice and recommendations for the selection, planning and configuration of system devices in the various types of room within a hospital can be found in the chapters Planning and Installation and Placement of devices which feature many diagrams and examples.

The standard programming of room terminals and the ward terminals are designed to display consecutive room and ward numbers (i.e. 01-... in an unbroken sequence). For its part the ward terminal also displays, in addition to the normal information, other further detailed information about individual wards and the various interconnections of wards. These devices can also optionally be supplied with a project-specific software package to display the actual (individual) layout.

4.1 Communication and security from your hospital bed


Patient handset as a handheld unit Moveable and easy to manoeuvre like a telephone receiver, it is the ideal communications device for the hospital bed. The follow functions are available as standard: call nursing staff, voice connection with staff members, operate reading light and room lighting and listen to the radio.

The following options are possible: Making telephone calls Controlling the rooms television and receiving TV sound Operating the patients television and receiving TV sound Pre- and post-paid outgoing telephone calls

Staff members use the same device if they require assistance. Each device contains a single chip processor running ist own software to enable fully autarchic intelligence from each bead, as well as a multiplex sound connection to the relevant room terminal.

19

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

4.2 Communication and safety in every room


Room terminals The room autarchic communications centre for every important room. From here nursing staff members and doctors can: indicate their presence, clear calls, acknowledge and query calls, Set reminders call for assistance and even make ward announcements.

Each room terminal contains its own computer system with multifunctional software and many new advantages - e.g.: designed for 6 beds with speech communication Room sanitary units beds without a speech connection, multiplex sound transfer to patient handsets, Membrane keypad, display for plain text display and LEDs that are not subject to wear and tear etc. Integrated TV controller for two room TVs (Loewe)

4.3 Communication and security in the wards nurses room


Ward Terminal The ward terminal is mainly used in the event of a decentralised system being in effect. Its large colour screen display and the surrounding functions keys arranged around it clearly display information for the user, such as: Presence lists arranged by room, Signalling and querying of calls, both chronologically and selectively Set reminders Bed, room and group announcements etc.

Password-protected programmer level and selection by room of group care and selection by bed of enhanced bed calls.

20

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

SystemDescription

4.4 Communication and security in the central query station


Control panel query Modern (multifunctional) colour graphical monitor system for control panel queries to create ergonomically perfect offices. Autarchic functionality with the following characteristics: Realistic (flicker-free) overlays of areas to display, context-sensitive graphic symbols and plan text descriptions, Choice of various listening devices and console modules, Hardware and software components for multifunctional application.

21

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

Datasheets
1 Connection Devices
For connecting patient handsets, for concealed installation or through service ducts; in the latter case for installation and wiring by the manufacturer of the service ducts.

1.1 Connection Device


To be installed in a double switchbox, for connecting patient handsets PBG/PBGT or push button BT-R/BT-RL; consisting of a supporting frame with a circuit board, which contains the necessary electronic components for amplifiers, call monitoring and addressing etc. as well as

One 15 pin connection socket (SUB-D) for connecting the patient handset or push button One connection socket (4 pin) for diagnostic calls, One 3 pole plug contact for headphones, with automatic sound switching when the listener plugs the headphones in. Connection for controlling a power supply relay Connector blocks for connecting the TV sound signal One connection panel with screw-free clips; incl. covering panel 160x83x13mm (HxWxD) in colour RAL 9010

Dimensions:

Type: SV

Order number: FC008302

1.2 Connection Device


To be installed in a service duct, for ribbon cable wiring to connect patient handset PBG/PBG-T or push button BT-R/BT-RL; consisting of a supporting frame with a circuit board, which contains the necessary electronic components for amplifiers, call monitoring and addressing etc.
One 15 pin connection socket (SUB-D) for the patient handset or push button connection socket (4 pin) for diagnostic calls, One 3 pole plug contact for headphones, with automatic sound switching when the listener plugs the headphones in. Connection for controlling a power supply relay Two connector blocks for connecting the TV sound signal One 40 pole connector base for ribbon cable connectors; Two 4 pole connector bases (for connection to a power supply relay) Circuit board for the (screw-free) snap-in attachment in the relevant prepared service ducts. Order number: FC008303

Type: SVSV-B

22

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

1.3 Connection Device


To be installed in a double switchbox, to connect patient handsets PBG/PBG-T or push button BT-R/BT-RL and to additionally use the telephony function of patient handset PBG-T; consisting of a supporting frame with a circuit board, which contains the necessary electronic components for amplifiers, call monitoring and addressing etc. as well as

One 15 pin connection socket (SUB-D) for the patient handset or push button One connection socket (4 pin) for diagnostic calls, One 3 pole plug contact for headphones, with automatic sound switching when the listener plugs the headphones in. Telephone module incl. in the connection device in the form of a extn. board Connection for controlling a power supply relay Connector blocks for connecting the TV sound signal One connection panel with screw-free clips; incl. covering panel 160x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008300

Dimensions: Type: SVT

1.4 Connection Device


To be installed in a service duct, for wiring the ribbon cable for connecting patient handsets PBG or push buttons BT-R/BT-RL and to additionally use the telephony function of patient handset PBG-T; consisting of a supporting frame with a circuit board, which contains the necessary electronic components for amplifiers, call monitoring and addressing etc. as well as

One 15 pin connection socket (SUB-D) for the patient handset or push button One connection socket (4 pin) for diagnostic calls, One 3 pole plug contact for headphones, with automatic sound switching when the listener plugs the headphones in. Telephone module incl. in the connection device in the form of a extn. board Connection for controlling a power supply relay Two connector blocks for connecting the TV sound signal One 40 pole connector base for ribbon cable connectors; Two 4 pole connector bases (for connection to a power supply relay) Circuit board for the (screw-free) snap-in attachment in the relevant prepared service ducts. Order number: FC008301

Type: SVTSVT-B

1.5 Connection Device

23

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets
To be installed in a double switchbox, to connect patient handsets PBG/PBG-T or push button BT-R/BT-RL, only for triggering calls and switching of 2 power supply relays, consisting of a supporting frame with a circuit board, which contains the necessary electronic components for call surveillance etc. as well as

One 15 pin connection socket (SUB-D) for the patient handset or push button One connection socket (4 pin) for diagnostic calls, One call button with a control LED, finder light included One connection panel with screw-free clips; incl. covering panel 160x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008310

Dimensions: Type: SVM

24

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

Patient handsets and Accessories

Patient handsets (in the form of handheld devices or for mounting into bedside cabinets) are the patients communications devices. Anyone can reach the nurse via his console and use additional convenient features.

2.1 Patient handset


The user-friendly handheld device for communication for the patient to allow rapid and easy triggering of calls and also containing other meaningful functions: 1x circuit board with a quartz-powered micro computer system, mask programs and amplifier for bed-autarchic functions, with multiplex processing for speech and 6 sound channels, with electronic volume control and program selection with last number redial and with a plug for the connecting cable; 1 membrane keypad to operate the unit, with: 1x display to display the time or number of the TV or radio program 1 call button (red, marked with a nurse symbol) with 2 control LEDs. (location lights) 2 lighting buttons with guide LED, 2 buttons for electronics volume control; 1 call button (red) on the top side of the handheld device, finder light included 1 loudspeaker and 1 microphone for voice connections or receiving sound; including 2.8m (plug-in) connecting cable with high tensile strength and a 15 pole SUB-D plug Dimensions: 218x60x25mm (HxWxD) plastic casing in colour RAL 9010 Order number: FC008210

Type: PBG

2.2 Patient handset


Technically and functionally the same as patient handset PBG described above, however, with the additional possibility of a telephone function using an additional integrated numeric keypad on the membrane keypad. A prerequisite for this is the use of a connection device with a telephone module (SV-T or SVT-B). After pressing the telephone button, a dialling tone will sound from the integrated loudspeaker, and the desired telephone number can be dialled using the numeric keypad. Depending on customer requirements, the telephone function can either be used for free or at a charge, via the VISOTAX PLUS billing system. For the latter option, a smartcard reader for ISO smartcards has been integrated in the PBG-T as standard.

Type: PBGPBG-T

Order number: FC008200

25

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

2.3 Patient handset TV


Technically and functionally identical to patient handset PBG-T described above, however, with a coiled connecting cable for connection to Patient TV Terminal PTVT.

Type: PBGPBG-TV

Order number: FC009604

2.4 Patient handset TV without call button


Technically and functionally like the patient handset PBG-TV described above, however without call button on the top of the unit and on the membrane keypad.

Type: PBGPBG-TVL

Order number: FC009608

26

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

2.5 Handheld buttons


The simple push button for the patient for rapid and easy call triggering, containing the necessary monitoring circuitry as well as: 1 call button (red, marked with a nurse symbol) with 2 control LEDs, finder light included. 15 pin SUB-D connector plug for connection with all connection devices with a SUB-D connector. Includes a 2.8m connection cable Dimensions: Type: BTBT-R 90x60x20mm (HxWxD) plastic casing in colour RAL 9010 Order number: FC008220

2.6 Push button


Simple push button for the patient for rapid and easy call triggering, with integrated lighting buttons for room lighting and the reading light, containing the necessary monitoring circuitry, as well as: 1 call button (red, marked with a nurse symbol) with 2 control LEDs, finder light included two lighting buttons (yellow, reading light and main light) with control LEDs. 15 pin SUB-D connector plug for connection with all connection devices with a SUB-D connector. Includes a 2.8m connection cable Dimensions: Type: BTBT-RL 90x60x20mm (HxWxD) plastic casing in colour RAL 9010 Order number: FC008221

2.7 Push button


Simple push button for the patient for rapid and easy call triggering, containing:

1 call button (red, marked with a nurse symbol) with 2 control LEDs, finder light included. 6.3mm jack plug for connection to unit SVM-K Includes a 2.8m connection cable 90x60x20mm (HxWxD) plastic casing in colour RAL 9010

Dimensions:

Type: BTBT-RK

Order number: FC008230

2.8 Mounting bracket


For securing the connection cable of the patient handset or the push button. Dimensions: 20x26x10mm (HxWxD) plastic case in colour red

Type: HKL VCP


27 product catalogue V1.2

Order number: number: FC006209


FC38502E-A

VISOCALL PLUS

Datasheets

2.9 Mounting clip


For securing the connection cable of the patient handset or the push button. Dimensions: 30x20mm (W x Diameter) Grooved metal piece in colour silver

Type: HL VCP

Order number: FC12803FC12803-

2.10 Headphones
For receiving radio and TV sound, with a 2.0m connecting cord, and a 3 pole 3.5mm diameter jack plug, for connection to connection devices and headphones connection socket.

Type: KH

Order number: FC005205

2.11 Cradle
To hold patient handsets from the PBG and BT series, made of plastic in colour RAL 9010, with mounting holes.

Type: HK PBG/BT

Order number: FC008240

28

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

Call and cancel button combinations

For installation in sanitary units and day rooms, for making or cancelling calls. The Telephone signalling device also indicates outstanding telephone calls from e.g. the wards nurses room.

3.1 Call button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

1 call button (red, marked with a nurse symbol) on a membrane keypad with 2 control LEDs, finder light included 1 connection panel with screw-free clips; incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008400

Dimensions: Type: RT

3.2 Pull button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

Membrane with a control LED, finder light included 1 connection panel with screw-free clips; including 2m cord with grip incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008410

Dimensions: Type: ZT

3.3 Pneumatic button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

Membrane with a control LED, finder light included 1 connection panel with screw-free clips; incl. 2 m pneumatic tubing with a pressure ball incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008420

Dimensions: Type: PT

3.4 Cancel button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

1 cancel button (green) on a membrane keypad with a control LED, 1 connection panel with screw-free clips; incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008430
FC38502E-A

Dimensions: Type: AT
29

product catalogue V1.2

VISOCALL PLUS

Datasheets

3.5 Call and Cancel button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

1 call button (red, marked with a nurse symbol) on a membrane keypad with a control LED, finder light included 1 cancel button (green) on a membrane keypad with a control LED, 1 connection panel with screw-free clips; incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008450

Dimensions: Type: RAT

3.6 Doctor Call button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

1 call button (orange, marked with a doctor symbol) on a membrane keypad with control LED, finder light included 1 connection panel with screw-free clips; incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008470

Dimensions: Type: ART

3.7 Presence button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

1 presence button (green, marked with a nurse symbol) on a membrane keypad with control LED 1 presence button (yellow, marked with a nurse symbol) on a membrane keypad with control LED 1 connection panel with screw-free clips; incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: number: FC008460

Dimensions: Type: AW2

3.8 Connection Device


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

1 connector for contact for push button type BT-RK 1 call button (red, nurse symbol) on a membrane keypad with control LED, finder light included 1 connection panel with screw-free clips; incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008320
FC38502E-A

Dimensions: Type: SVMSVM-K


30

product catalogue V1.2

VISOCALL PLUS

Datasheets

3.9 Noise Noise Monitor


For connection to connection devices SV/SVT/SV-B/SVT-B or SVM, consisting of a plastic case, as well as:

1 call button (red) on a membrane keypad to trigger calls with a control LED. 1 function key (green) to activate the noise monitor 15 pin SUB-D connector plug for connection with all connection devices with a SUB-D connector. Includes a 2m connection cable 50x110mm (H x Diameter) in colour RAL 9010 Order number: FC008480

Dimensions:

Type: SW

3.10 Telephone call unit


To initiate an acoustic call forwarding signal when Telephone calls are received and the receiver is not picked up, the function being integrated into the software structure of the room terminal and the ward terminal; for surface mounting. Caution: For unit D1/F a screw clip (STV) must also be ordered, see below.

Type: D1/F Type: STV

Order number: YY208980 Order number: FC78737FC78737-

31

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

Signal lamps

For the widest possible range of uses the VISOCALL PLUS system offers various signal lamps. Both soffit lamps and LED signal lamps are used as room signal lamps and as direction signal lamps.

4.1 LED Signal lamp


Multiple LED signal lamp with up to 5 LEDs per lamp, for use as room and direction signal lamps and for surface installation or mounting on U1 or H1 single switchboxes; consisting of:

Circuit board with 5 LED panels 5 translucent plastic segments 2 grey plastic cabs at the top and at the bottom 86x86x52mm (HxWxD) pyramid shaped rd rd/gn wh/rd/gn rd/gn/or wh/rd/gn/or wh/rd/gn/ye/or Order number: FD8061 FD806101 6101 Order number: FD8062 FD80620 6201 Order number: FD8063 FD806301 6301 Order number: FD8063 FD806302 6302 Order number: FD8064 FD80640 6401 Order number: FD8065 FD806501 6501

Dimensions:

Type: ORION 1S Type: ORION 2A Type: ORION 3A Type: ORION 3B Type: ORION 4A Type: ORION 5

4.2 Room signal signal lamp


Single, opal-coloured; consisting of a base with 1 holder (including clips) for 1 soffit lamp including trapeziform lamp cover 85x85x42mm

Type: LV1

Order number: FD805100

4.3 Room signal lamp


Double, opal-coloured; consisting of a base with 2 holders (including clips) for 2 soffit lamps as well as 1 dividing wall including trapeziform lamp cover 85x85x42mm

Type: LV2

Order number: FD804200

32

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

4.4 Room signal lamp


Triple, opal-coloured; consisting of a base with 3 holders (including clips) for 3 soffit lamps as well as 2 dividing walls including trapeziform lamp cover 85x85x42mm

Type: LV3

Order number: FD804300

4.5 Direction signal lamp


Single, opal-coloured; consisting of a base with 1 holder (including clips) for 1 soffit lamp including trihedral lamp cover 85x85x74mm

Type: LD1

Order number: FD803100

4.6 Direction signal lamp


Double, opal-coloured; consisting of a base with 2 holders (including clips) for 2 soffit lamps as well as 1 dividing wall including trihedral lamp cover 85x85x74mm

Type: LD2

Order number: FD803200

4.7 Direction signal lamp


triple, opal-coloured; consisting of a base with 3 holders (including clips) for 3 soffit lamps as well as 2 dividing wall including trihedral lamp cover 85x85x74mm

Type: LD3

Order number: FD803300

33

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

4.8 Group signal lamps


For n*) wards, consisting of a base frame (colour RAL 1013) for surface installation with n*) signal lamps of type LD1 each with 1 holder (including clips) for 1 soffit lamp Type: Rn*)xLD1 Order number: YY20851n*)

For n*) wards, consisting of a base frame (colour RAL 1013) for surface installation with n*) signal lamps of type LD1 each with 2 holders (including clips) for 2 soffit lamps as well as 1 dividing wall Type: Rn*)xLD2 Order number: YY20852n*)

For n*) wards, consisting of a base frame (colour RAL 1013) for surface installation with n*) signal lamps of type LD3 each with 3 holders (including clips) for 3 soffit lamps as well as 2 dividing walls Type: Rn*)xLD3 Order number: YY20853n*)

Type and Order numbers: Instead of n, the number of wards that can be combined into one area is to be used; e.g.; Group signal lamps for 4 wards, consisting of a base frame (colour RAL 1013) for surface installation with 4 signal lamps of type LD3 each with 3 holders (including clips) for 3 soffit lamps as well as 2 dividing walls Type: R4xLD3 Dimensions: L=(n*) x 86) + 24mm, W = 103 mm, H = 90 mm Order number: YY208534

4.9 Soffit lamps


24V / 5W for room, direction and group signal lamps; Length (tip to tip) = 42mm, diameter 14mm

Type: Gd5Gd5-9 Type: Gd5Gd5-2 Type: Gd5Gd5-3 Type: Gd5Gd5-6 Type: Gd5Gd5-7
34

wh rd gn ge or

Order number: FL73309FL73309Order number: FL73310 FL7331010Order number: FL73311FL73311OrderOrder-number: FL73321FL73321OrderOrder-number: FL73330FL73330FC38502E-A

product catalogue V1.2

VISOCALL PLUS

Datasheets

Room terminals

For countersunk installation in patient rooms and other important rooms; communications centres for nursing staff, for ELAC reception etc.

5.1 Room terminals


With integrated functions and user membrane with coloured panels and symbols; consisting of 1 connecting circuit board for installation with countersunk case type "ZEK2" or "HZEK2" or surface mounted case "APA-ST", with screw clips (for power supply connections) and screw-free clips (other connections), with fuse and terminating resistors as well the connecting base for the room terminals control unit; 1 box frame, for the screwless installation of the room terminal control unit; 1 Room terminal control unit for connection to the connecting circuit board, comprising of - 1 Terminal case with speaker and microphone apertures as well as a membrane with user panels; built into the terminal case - 1 function circuit board with single chip processor, 10W lamp outputs and DIL switches for addressing and selection functions; designed for 6 beds with or without speech communication, sanitary unit for additional rooms without speech connection; designed for multiplex sound transmission to beds, ELAC reception, group announcement and group signals, 1 call button (red, marked with a nurse symbol) with control LED, finder light included 1 query off button (white, question mark symbol) with control LED 1 call button (orange, marked with a doctor symbol) with control LED. 3 presence buttons (green/nurse, yellow/helper nurse, orange/doctor) each with a control LED, 1 loudspeaker and 1 microphone Room terminal with connecting circuit board, case frame and control unit with standard programming, ready for addressing and connection. The TV control unit is included in the electronics of the ST. To use the TV control unit, a 3 pin connection cable (not included in the delivered unit) must be connected from the ST to the distribution board. Dimensions: 255x176x25mm (HxWxD) plastic casing in colour RAL9010

Necessary components for countersunk mounting: Type: ST Type: VST Type: DRDR-ST Type: HZEKHZEK-2 Necessary components for surface mounting: Type: ST Type: VST Type: APAAPA-ST Order number: FC008102 Order number: FC008100 Order number: FC008990 Order number: FC008102 Order number: FC008100 Order number: FC008101 Order number: FC88008FC88008-

35

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

5.2 Room terminals terminals


With integrated functions and user membrane with coloured panels and symbols; consisting of 1 connecting circuit board for installation with countersunk case type "ZEK2" or "HZEK2" or surface mounted case "APA-ST", with screw clips (for power supply connections) and screw-free clips (other connections), with fuse and terminating resistors as well the connecting base for the room terminals control unit; 1 case frame, for the screw-free installation of the room terminal control unit; 1 Room terminal control unit for connection to the connecting circuit board, comprising of - 1 Terminal case with speaker and microphone apertures as well as a membrane with user panels; built into the terminal case - 1 function circuit board with single chip processor, 10W lamp outputs and DIL switches for addressing and selection functions; designed for 6 beds with or without speech communication, sanitary unit for additional rooms without speech connection; designed for multiplex sound transmission to beds, ELAC reception, group announcement and group signals, 1 display unit 2 lines each with 16 characters 1 call button (red, marked with a nurse symbol) with control LED, finder light included 1 query off button (white, question mark symbol) with control LED 1 call button (orange, marked with a doctor symbol) with control LED. 3 presence buttons (green/nurse, yellow/helper nurse, orange/doctor) each with a control LED, 1 loudspeaker and 1 microphone Room terminal with connecting circuit board, case frame and control unit with standard programming, ready for addressing and connection. The TV control unit is included in the electronics of the ST-D. To use the TV control unit, a 3 pin connection cable (not included in the delivered unit) must be connected from the STD to the distribution board. Dimensions: 255x176x25mm (HxWxD) plastic casing in colour RAL9010

Necessary components for countersunk mounting: Type: STST-D Type: VST Type: DRDR-ST Type: HZEKHZEK-2 Necessary components for surface mounting: Type: STST-D Type: VST Type: APAAPA-ST Order number: FC008103 Order number: FC008100 Order number: FC008990 Order number: FC008103 Order number: FC008100 Order number: FC008101 Order number: FC88008FC88008-

36

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

Mini terminal

Mini terminal for connection to the ward bus (like room terminals) for areas without speech connection. Designed for calls, emergency calls, presence indication, call forwarding, doctor calls and doctor presence. Cancelled and displayed at the main query location and the query control centre.

6.1 Mini terminal


For installation in a double switchbox; consisting of a supporting frame with circuit board, a single chip processor, DIL switches for addressing and button programming.

1 display unit 2 lines each with 16 characters 1 call button (red) with control LED (red), finder light included can be programmed using DIL switches: - Room call button with indicator lamp - WC call button with indicator lamp presence buttons, orange button (doctor) and green button (nurse) including control LEDs and can be programmed using DIL switches. - Presence button (nurse) with cancel function and presence indicator lamp - Presence button (nurse) without cancel function and presence indicator lamp - Cancel button 1 doctor call button (orange) including control LED (orange) The doctor call input can also be programmed and used as a second WC call input via the DIL switches. In this case the doctor call function is disabled. 1 audible alarm (call forwarding) 1 diagnostic call circuit indicator lamp outputs (dependent on programming) call lamp circuits (each 10 Watt) 1 presence lamp circuit (10 Watt) including connection panel with screw-free clips; including covering panel 160x83x13mm (HxWxD) plastic casing in colour RAL 9010 Order number: FC008115

Dimensions:

Type: STMSTM-AD

6.2 Mini terminal


As per 6.1 but without display

Type: STMSTM-A

Order number: FC008114

37

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

6.3 Mini terminal


As per 6.1 but without doctor call and presence buttons.

Type: STMSTM-D

Order number: FC008113

6.4 Mini terminal


As per 6.1 but without display and without doctor call and presence buttons.

Type: STM

Order number: FC008112

38

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

Bus interface

For controlling group signal lamps as well as activating the paging system and message transfer; the necessary control modules must be ordered separately.

7.1 Bus interface


Fr controlling group signal lamps, activating the paging system and for messages to the in-house IT centre; consisting of

1 connecting circuit board for mounting in type GBI installation case, with screw clips (for power supply connections) and screw-free clips (other connections), with fuse and multipoint plug base for the controller bus interface as well as four multipoint plug bases for a maximum of four control modules of type TBI or RBI, 1 controller bus interface (connectable) with microcomputer systems and DIL witches for addressing and assignment of functions; ready for addressing and connection For installation in unit GBI (Bus interface case) - see point 7.4

A functioning group terminal contains the following components: Type: VBI Type: CBI Type: GBI Order number: FC008500 Order number: FC008503 Order number: FC008504

For extra fitting upon demand:

7.2 Transistor Bus interface


Fr connection in the bus interface distributor of type "VBI"; with the necessary electronics and outputs for 8 lamp circuits (each 10 Watt)

Type: TBI

Order Order number: FC008501

7.3 Relay Bus interface


Fr connection in the bus interface distributor of type "VBI"; with the necessary electronics and outputs with 8 make contacts (voltage-free, each 1A/60V=)

Type: RBI

Order number: FC008502

39

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

7.4 Bus interface interface case


Polycarbonate plastic case for surface mounting for installation of the bus interface distributor VBI. Screw-on cover with rubber seal Colour: shiny light grey, similar to RAL 7035

Dimensions:

264x214x91mm (HxWxD)

Type: GBI

Order number: FC008504

40

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

Miscellaneous

Various components for assorted special functions

8.1 Group call interface


For fitting to room terminals (insertion into the installation case) for activating a direction lamp circuit for as many rooms as required; consisting of a circuit board with a microcomputer system programmed using masks and outputs (10 watts) for

Call display, Reminder / Nurse, Reminder / helper nurse and Reminder doctor;

including wiring connections and connection panel with screw-free clips; Type: SI Order number: FC008910

8.2 Radio Controller


For installation in a single switchbox, for connection to room terminals with ELAC reception, consisting of a supporting frame with circuit board, on which there is a mask programmed microcomputer system for 6 programs with last program memory and electronic volume control; consisting of:

1 program button (P), 1 single character display for displaying the selected program and buttons (< and >) for volume control.

including connection panel with screw-free clips and covering panel Dimensions: Type: RDF 80x83x13mm (HxWxD) in colour RAL9010 Order number: FC008130

8.3 Power supply relay


For operating light sources e.g. room lights and/or reading light. The relay is connected to the relevant connection device and operated via patient handset PBG or PBG-T or via push button BT-RL and consists of:

a plastic case with the following connections connection clips for 24V inductance coil connection clips for potential-free contact (250V~/10A) 29x61x26mm (HxWxD) Order number: FC008996

Dimensions:

Type: FS1/24DC

41

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

8.4 Control module


Foreign systems e.g automatic blinds can be controlled using this module. The systems are operated only with patient handset PBG-T. The module consists of:

a plastic case with connection clips for the room bus Connection clips for the foreign system 25x85x42mm (HxWxD) Order number: FC008340

Dimensions: Type: SM

8.5 Diagnostic extension


For extending the diagnostic connection in a patient bed. Up to 4 additional foreign devices can be connected to the diagnostic extension. It comprises of:

Printed circuit board with electronics for installation in a double connection box or in a double surface mounted case. Connection socket (4 pin) for diagnostic calls Screw-less connection clips for extensions for each patient bed incl. covering panel 160x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008330

Dimensions:

Type: DE

8.6 Intercom Terminal


Allows call handling from an external location. The doorphone intercom can either be used for a barrier system or external doors. It is connected to typical VISOCALL PLUS nursecall components via the ward bus. If a call is made from this doorphone and queried from another location, (ward terminal or room terminal) and a reminder then set, then a GND signal is sent to lamp output L-S1 for 5 seconds (if a S1 reminder has been set) and to lamp output L-S2 for 500 milliseconds (if an S2 reminder has been set) on the door terminal. This allows, for example, a magnetic door opener to be controlled.

1 stainless steel call button Integrated speaker and microphone Connection panel with screw clips 255x160x40mm (HxWxD) stainless steel metal case

Dimensions:

Necessary components for countersunk mounting: Type: IT Type: HZEKHZEK-2 or Type: ZEKZEK-2 Order number: FC88009FC88009Order number: FC008110 Order number: FC88008FC88008-

42

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

8.7 Door terminal


Room terminal without a display, and with a special membrane keypad and special software. The installation process is analogue to that of conventional room terminals. If a call is made from this terminal and queried from another location, (ward terminal or room terminal) and a reminder then set, then the special software sends a GND signal to lamp output L-S1 for 5 seconds and to lamp output L-S2 for 500 milliseconds. This allows, for example, a magnetic door opener to be controlled.
1 connecting circuit board for installation in countersunk case type "ZEK2" or "HZEK2" or surface mounted case "APA-ST", with screw clips (for power supply connections) and screw-free clips (other connections), with fuse and terminating resistors as well the connecting base for the room terminals control unit; 1 case frame, for the screw-free installation of the room terminal control unit 1 room terminal control unit to connect into the connecting circuit board comprising of: - 1 terminal case with speaker and microphone apertures as well as a membrane with user panels; built into the terminal case - 1 function circuit board with a single chip processor, 10 W lamp outputs, and DIL switches for addressing and selection of functions;

1 call button (red, with nurse symbol) with a control LED, finder light included 1 loudspeaker and 1 microphone; Dimensions: 255x176x25mm (HxWxD) plastic casing in colour RAL9010

Necessary components for countersunk mounting:


Type: STST-Tr Type: VST Type: DRDR-ST Type: HZEK HZEKEK-2 Order number: FC008105 Order number: FC008100 Order number: FC008101 Order number: FC88008FC88008-

Necessary components for surface mounting:


Type: STST-Tr Type: VST Type: APAAPA-ST Order number: FC008105 Order number: FC008100 Order number: FC008990

43

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

Text terminal

Display in corridor for recapitulating displaying of emergency calls, calls, reminders, time and date

9.1 Connection splitter to text displays


For installation in a double switchbox consisting of a supporting frame with a connecting circuit board for the splitting and clearing of bus connections, equipped with the necessary clips, a plug block for attaching the connecting cable for the text terminal, as well as power supply protection with fuses. Dimensions: including covering panel 160x83x13mm (LxWxD) plastic case in colour RAL 9010

Type: VTXT

Order number: FC008815

9.2 Text terminal


12 character LED display with terminal amplified loudspeaker for wall mounting for recapitulating display of emergency calls, calls and reminders by group. Displays the call that is most important according to the priority scheme, with a changing display, if there are several calls. Displaying of group/ward 3 characters e.g. G02 Displaying of room 3 characters e.g. 203 Displaying of room 2 characters e.g. B1 By using the integrated RS485 interface, texts from other sources can be displayed on the text display. The relevant corresponding item, a PC, uses software to load the text in to the corridor display. The current time is displayed in standby mode, and the unit is made up of a series of modules, consisting of an independent microcomputer system for independent data processing, evaluation and controlling of 12 LED matrix displays, character height 80mm, mounted in an aluminium casing. Dimensions: Type: TXT 978x110x40mm (LxWxD) Order number: FC008810

9.3 Text terminal


With a 12 character alphanumeric display and loudspeaker with wall mounting, adjustable. Functions as described in 9.2. Type: TXTTXT-W Order number: FC008811

44

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

9.4 Text terminal terminal


With a 12 character alphanumeric display and loudspeaker for ceiling mounting, adjustable. Functions as described in 9.2. The text terminal can be suspended at variable heights between 820 and for about 1000mm from the ceiling using the flange.

Type: TXTTXT-D

Order number: FC008812

9.5 Text terminal


A double display consisting of two 12 character alphanumeric displays facing in opposite directions and loudspeakers with wall mounting bracket, adjustable. Functions as described in 9.2.

Type: Type: TXTTXT-2W

Order number: FC008813

9.6 Text terminal


A double display consisting of 2 opposite facing 12 character alphanumeric displays and loudspeakers with ceiling mounting bracket, adjustable. Functions as described in 9.2. The text terminal can be suspended at variable heights between 820 and for about 1000mm from the ceiling using the flange.

Type: TXTTXT-2D

Order number: FC008814

45

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

10 Ward Terminal
For area-related and general signalling, speech connections, announcements etc. Each query location automatically recognises it corresponding area.

10.1 Ward Terminal


For ward-autarchic deployment in decentralised systems for connection to connecting terminal of type "AE-DZT"; consisting of a table mounted case, in the usual Visocall Plus look with a receiver rest, containing:

1 function circuit board with a microcomputer system and the necessary interfaces, designed for all the functions that can be queried here, as well as for interconnection of groups, group care, interconnection of rooms from different wards and enhanced patient calls; furthermore designed for programming (addressing, automatic time-related formation of groups etc.). simple to use thanks to multiple uses of function keys Colour graphic display, 1/4 VGA resolution (320 x 240 pixels) with relevant menu display and status and functions line blue function keys to the left and right of the display for menu selection purposes yellow function keys below the display for scrolling or also for menu selection purposes RS232 interface for connection to control panel 1 sound emitting device for acoustic signals as well as 1 query receiver (connectable) containing a loudspeaker and microphone unit, can automatically be switched to hands-free mode and built-in for this purpose. 1 loudspeaker and 1 microphone Volume and microphone levels can be set via the software menu Ward terminal with standard configuration program for system related settings without opening the case including 3m connection cord and multipole connector plug.

When the ward terminal is connected to a control panel, the control panel receives all the relevant information it requires from the ward terminal via the RS232 serial interface. The ward terminal itself is then used a hands-free unit or as a classical handset.

Dimensions:

310x232x35mm (LxWxD) plastic case in colour RAL 9010

Type: DZT

Order number: FC008001

46

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

10.2 Connecting terminal


For connection of a ward terminal or a ward interface; consisting of:

Plastic cover (ST) for connection of the ward terminal. using integrated multiple connector plug ribbon cable connection ready for connection to the distribution board "V-DZT" 255x176x50mm (HxWxD) plastic casing in colour RAL9010

Dimensions:

Type: AEAE-DZT *) Parts for "AE-DZT": 1 Cover FC008003-1 distribution board -Type: A-DZT V-DZT

Order number: *) Order number: FC81441-

Necessary components for installation in a countersunk case: Type: DRDR-ST Order number: FC008101

Necessary components for installation in a surface mounting case: Type: APAAPA-ST Order number: FC008990

47

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

11 Control panel/Ward control panel


For area-related and system-related signalling, speech connections, announcements etc. Each query location automatically recognises it corresponding area.

11.1 Nurse call Software - Control Panel


Software license for the Windows-based application with a graphical user interface for centralised or decentralised system configurations. The control panel can communicate with all the ward terminals connected in the system and can monitor all activities for the ward which it controls or for the system as a whole and react accordingly. An SQL database is installed on the PC in conjunction with this application. Control panel software: A graphical representation of the ward which the control panel is in or all interconnected wards offers a rapid overview of the nurse call components integrated in the system. Regardless of call location and call priority, the control panel can react to a call by means of a single mouse click, connect a call and, if necessary, set the relevant reminder. Equally it is possible to select a single room or bed, as per general announcements and those destined for specific people; the latter being applicable for nurses as well as for doctors. The system distinguishes between announcements intended for the ward in which the control panel is located and those intended for the entire system. Up to 7 care groups per ward can also be assigned up the freely selectable group care options in the standard software.

Minimum system requirements: see point 11.9 Order number: FC008050

Type: SWPSWP-LS

11.2 Software - Control panel extensions


Software license for control panel extension - adding an additional control panel in an already functioning VISOCALL PLUS system. Using this extension, a fully functional control panel is available for use in the ward in which it is located as well as in multiple wards.

Minimum system requirements: see point 11.9 Order number: FC008052

Type: Type: LSE

11.3 Software - Patient database


Software license to use a patient database in conjunction with a nurse call control panel. Consequently, when a call is connected, the most important patient information will be displayed as an overview on the nurse call control panel.

Minimum system requirements: see point 11.9 Order number: FC008055

Type: SWPSWP-PV

48

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

11.4 Software - Event database


Software license for logging all events within the VISOCALL PLUS system. The records can be displayed or printed out clearly by setting various filters. This software package can also be used without a nurse call control panel.

Minimum system requirements: see point 11.9

Type: SWPSWP-EDB

Order number: FC008056

11.5 Software - Foreign System Connection


Software license for data connection of a foreign system. Data is either transferred from the VISOCALL PLUS system to the foreign system or from the foreign system to the VISOCALL PLUS system as required via the RS232 serial interface. These systems can be, for example, the central process control system, the alarm server or the BMZ Integral fire alarm control panel. A separate serial interface is required for each additional connection to a foreign system.

Minimum system requirements: see point 11.9 Order number: FC008057 Order number: FC008059

Type: SWPSWP-AS Type: SWPSWP-ISP

11.6 Toolbox
The toolbox contains a CD for the installation as described in the software modules from 11.1 till 11.5. The applications will beinstalled with this CD but not licensed.

Minimum system requirements: see point 11.9 Order number: FC008040

Type: SWPSWP-TP

11.7 Connection cable for Control Panel


The connection cable is used for establishing a physical connection between the ward terminal and the control panel. It is designed specifically for use with a control panel. pin plugs (RS232) at both ends for connecting to the control panel and the ward terminal. Length: 3m Order number: ZZH08051

Type: Type: LSTLST-AK

49

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

11.8 Service Monitor Connection Cable


The connection cable is used for establishing a physical connection between the ward terminal and the control panel. It is also possible to carry out programming of the firmware as well as customer specific programming using this cable. 9 pin plugs (RS232) at both ends for connecting to the control panel and the ward terminal. Length: Type: SMK ca. 3m Order number: FC008051

11.9 Control Panel - Hardware package


The hardware package consists of a computer with at least one free serial interface for connection to ward terminal DZT. On the hardware there have to be installed only WINDOWS 2000 (Service Pack 3 or higher) or WINDOWS XP pro (Service Pack 2 or higher). Minimum system requirements:

Intel Pentium 1.8Ghz RAM: min. 512KB HDD 80GB, DVD-ROM LAN Intel 10/100/1000 onboard, RJ45 connection VGA Graphics card (onboard or PCI) Keyboard and mouse 1 serial interface

Type: LSLS-HW Type: Monitore VGA

Order number: number: FC008053 Order number: on demand

50

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

12 Interfaces
The central interface acts a central interface between all ward terminals installed in the system. Furthermore, foreign systems can also be connected, so that status information about the nurse call system can also be used outside of VISOCALL PLUS.

12.1 Central interface


For networking up to 15 wards or ward terminals and integrated interfaces to foreign systems, e.g. Potential-free inputs and outputs Analogue AF input for importing external audio sources with mandatory reception characteristics consisting of:

Central master circuit board pole SUB/D socket for upload and configuration using a PC Insertion slots for expansion using slave components Blue metal case for surface installation in electricity distribution case Ambient temperature: 0C to +50C Relative Air Humidity: 5-95% without condensation

Dimensions: Weight: Type: ZI

345x300x105mm (WxHxD) 5kg Order number: FC008002

12.2 Central interface slave


For extending the central interface by an extra 15 wards or ward terminals.

Type: ZIZI-S

Order number: FC81443FC81443-

12.3 QSIG Data interface


A call made using the nurse call system, which has not been queried within a predefined time limit, can be diverted to a DECT handset by means of the DECT connection. The location of the call and the type of call can be displayed based on available data on the handset's display. Nursing staff members will be alerted to this message by means of an acoustic signal being emitted by the DECT handset.

Type: SWPSWP-QD

Order number: FC008041

51

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

12.4 QSIG Speech/data interface


A call made using the nurse call system, which has not been queried within a predefined time limit, can be diverted to a DECT handset by means of the DECT connection. Nursing staff members will be alerted to this call by means of an acoustic signal being emitted by the DECT handset. The location of the call and the type of call can be displayed based on available data on the handset's display. The member of the nursing staff can receive the call by either pressing the button "Answer telephone" or the "Yes" key, and talk to the relevant person. A prerequisite for this is that the call has been made from a component with speech capability. The person making the query is also in the position to then set a reminder via DECT. Type: SWPSWP-QSD Order number:FC008042

52

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

13 TV devices and accessories


For the room-by-room extension of the nurse call system, in order to offer patients the chance to take advantage either of a room TV set or a patient TV terminal.

13.1 55cm TV set


TV set for watching television in the room; it can be mounted on the opposite wand to the patient using the wall console. The external loudspeaker is deactivated, and the TV set can be controlled using the VISOCALL PLUS nurse call system. A requirement for this to be possible is a three pole connection cable between the unit "ST" / "ST-D" and the "VST". This cable is used for transmitting IR control signals. Electrical details: Power supply: Power consumption: 230V/50Hz in operating mode, max. 65W (including additional hospital interface power supply) standby mode, 9W < 40 C VHF 2-12, UHF 21-69, S1-S41 100 PAL BG, DK Optional: PAL I, H, SECAM BG, DK, L/L NTSC over EURO AV

Ambient temperature: Tuner VHF/UHF/cable (Hyperband): Program memories: TV Standards:

Mechanical details: Tube: Format: Dimensions: Weight: Connections: IEC socket: Hospital interface: 75 Ohm, aerial / cable Interface for VISOCALL PLUS (RSIG) IR and sound (Scart II) Full load max. 25W Standby 5W 21, 55cm, visible 51cm 4:3 440x490x470mm (HxWxD) 19.8 kg

Power cable and plug integrated into the set. TV set in colour RAL9010 Type: SOLEX M55B Order number: FC007020

53

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

13.2 Wall console


Wall console for wall mounting of TV set Solex M55B (see point 13.1).

Metal console, with an attachment plate to attach the TV set to Flange prepared for wall-mounting

Dimensions: Mounting flange: 355x205x25mm (HxWxD) Arm: 40x30x365mm (HxWxL) Mounting panel: 430x275mm (WxD), 3 mm panel Type: WKWK-S Order number: FC007004

13.3 Connection Cable


Connecting cable for the transmission of IR control signals from the distribution board "VST" to the electronics of "ST" or of "ST-D".

pole cable with pre-fitted plug at both ends Order number: FC81806FC81806-

Type: KABKAB-VST

13.4 Connecting unit


Connecting unit for installation in single switchboxes, consisting of:

1 carrying ring with a 5 pole / 270 DIN socket

The cover is to be provided for separately, to match the switch used.

Type: AEAE-FAK

Order number: YY241011

13.5 TV Cable set


Connecting cable to connect the TV set to the connecting unit described below in 13.4, consisting of:

Aerial cable for transmission of the aerial signal SCART cable for transmission of the IR and sound signal

Type: TVTV-KOAX Type: TVTV-SCART

Order number: FC81712FC81712Order number: FC81729FC81729-

54

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

13.6 Programming module


Connecting plug for the TV set, to save TV specific settings and for re-entering into other TV sets, consisting of:

SCART plug with integrated memory unit

Type: SOLEX E9A

Order number: FC007026

13.7 Service remote control


Service remote control for TV set for setting TV-specific information.

Type: PR106GR

Order number: FC007025

55

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

13.8 TV Terminal
TV Terminal for watching television and listening to the radio for each bed. The unit is mounted on a wall-mounted arm or an arm attached to the bedside cabinet and can easily and comfortably be moved into any desired position by using the hand grip; The screen can either be delivered in a 10 or a 12 screen size (see article no.), with the plastic case being the same size for both versions. Games console/DVD: Y/C and CVBS inputs can be found on the underside of the unit for connecting a games console or a DVD player respectively. Reading light:: A reading lamp on the underside of the unit provides adequate light. The neighbouring patient will not be disturbed by this lighting source. Electrical details: Power supply on console: Power consumption: Ambient temperature: Tuner VHF/UHF/cable (Hyperband): recommended signal strength: TV program memoriess: Radio program memories: TV Standards: Mechanical details: Monitor: Format: Dimensions: Weight: Connections: IEC socket: Y/C, Hosiden DIN socket: CVBS, Cinch socket: Audio left/right, Cinch WH/RD: 3.5mm jack plug: 75 Ohm, aerial / cable SVHS input Cinch input - video Cinch input audio Output for stereo sound TFT LCD 10", 640x480 pixels (VGA) 12", 800x600 pixels (SVGA) 270x370x55mm (HxWxD) 3 kg 230V~/50Hz 50W (see 13.12/13.17) in operation 12V/40W (including reading light) standby mode typically +5C to +40C TV: 48.25MHz to 855.25MHz Radio: 87.5MHz to 108MHz >65dBV for TV reception >30dBV for stereo radio reception 99 99 PAL B/G for Austria, Germany and Italy

Caution: When using a TVT unit, the handset must be ordered separately. Two different versions of handset exist for this purpose, see points 2.3 and 2.4.

Type: TVTTVT-12

Order number: FC009601

56

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

13.9 Multimedia Terminal


TV Terminal as described in 13.8 with the added possibility of internet access. The unit is either mounted on a wall-mounted arm or a bedside cabinet-mounted arm, and can be moved easily and comfortably to any position using the handle. Games console/DVD: Y/C and CVBS inputs can be found on the underside of the unit for connecting a games console or a DVD player respectively. Reading light:: A reading lamp on the underside of the unit provides adequate light. The neighbouring patient will not be disturbed by this lighting source. Internet:: A embedded PC is integrated into the Multimedia Terminal, which is connected to the applications server , see 13.11, via a CAT5 LAN connection. The operating system is loaded from this server. The patient has the opportunity to surf the internet/intranet using the wireless keyboard with integrated trackball. Electrical details: Power supply on console: Power consumption: Ambient temperature: Tuner VHF/UHF/cable (Hyperband): Recommended signal strength: TV program memoriess: Radio program memories: TV Standards: Mechanical details: Monitor: Format: Dimensions: Weight: Connections: IEC socket: USB socket: CVBS, Cinch socket: Audio left/right, Cinch WH/RD: 3.5mm jack plug: 75 Ohm, aerial / cable input for USB keyboard Cinch input - video Cinch input - audio Output for stereo sound TFT LCD 12", 800x600 pixels (SVGA) 270x370x55mm (HxWxD) 3 kg 230V~/50Hz 50W (see 13.2/13.17) in operation 12V/40W (including reading light) standby mode typically +5C to +40C TV: 48.25MHz to 855.25MHz Radio: 87.5MHz to 108MHz >65dBV for TV reception >30dBV for stereo radio reception 99 99 PAL, SECAM, PAL I, PAL D/K, SECAM L/L, SECAM D/K

Caution: When using a MMT unit, the handset and keyboard must be ordered separately. Please consult points 2.3, 2.4 and 13.20. Type: MMT Order number: FC009614

57

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

13.10

Internet keyboard with trackball


Cordless keyboard with integrated trackball for operating MMT in Internet operation.

Type: on demand

Order number: on demand

13.11

Internet application server


The Internet application server acts as the central interface between the multimedia terminals installed in the hospital and the Internet/Intranet.

Intel 2,8 GHz Min. 4GB RAM min. 80 GB HDD IDE (Suse Linux 9.0 kompatibel) min. 48x DVD-R LW FDD 3.5 1.44MB LAN Intel 10/100/1000 onboard, RJ45 connection LAN network card PCI 100Mbit, RJ45 connection 56Kbaud Modem (Remote maintenance) Keyboard and mouse (including mousepad) operating system Suse Linux 9.0 Including all necessary applications

Caution: The maximum number of patients simultaneously surfing the Internet will be assumed to be approx. 10% of all MMT units in operation. If the above number of 30-40 is exceeded, we recommend installing an extra application server. Internet set-up times on MMT units will thereby be shortened.

Type: APSAPS-MMT

Order number: FC009618

58

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

13.12

Wall console
Wall console for wall-mounting of the patient TV terminal.

230V~ AC power supply connection Aerial connector case for connecting aerial wires Metal panel for mounting the console on the wall Plastic covering in colour RAL9010

Caution: neither unit SV-B, SVT-B nor TVI are included as supplied. Dimensions: Weight: Metal base plate: Cover: 8 kg 249x241x14mm (HxWxD) 290x245x12.5mm (HxWxD)

Type: WKWK-TVT

Order number: FC009605

13.13

Wall mounted arm


Wall mounted arm for attaching the patient TV terminal to the wall console

jointed swivelling arm, moveable through all three axes. Bottom joint of the arm can be tilted up to 50 Internal pre-fitted cable Case made of metal in colour RAL9010

Dimensions: Extended: Upper arm: Lower arm: Weight: 220x1710x70mm (HxWxD) 105x750x70mm (HxWxD) measurement points to the centre of the joints 80x800x70mm (HxWxD) measurement points to the centre of the joints 10 kg

Type: WAWA-TVT LAN

Order number: FC009606

13.14

Grip for TVT/MMT


Metal grip for the correct positioning of the TV- or the Multimedia terminal.

Comfortable to use modern design hand grip, silver

Type: WAWA-Griff

Order number: FC009607

59

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

13.15

Bedside cabinetcabinet-mounted arm


For mounting the patient TV terminal on a bedside cabinet, consisting of:

Shaped metal tube in colour RAL9010 Internal pre-prepared cable for various connections 850x500x35mm (HxW x Diameter) 6 kg

Dimensions: Weight:

Type: NANA-TVT

Order number: FC009612

13.16

Mounting bracket bracket


Metal bracket for holding the bedside cabinet-mounted arm, consisting of:

Aluminium cast part in colour RAL 9010 Aluminium base plate for fixing to the bedside cabinet or item of furniture

Dimensions:

150x60x70mm (HxWxD)

Type: NANA-H

Order number: FC009613

13.17

Network box LAN


Network box for bedside cabinet-mounted arm for TVT variants, consisting of:


Caution:

Metal case in colour RAL 9010 Connection box for aerial connection (coaxial cable) LAN connection (only applicable for Multimedia Terminal) Connection clips 230V~ Alternating Current 12V DC power supply Mounting holder for TVI and SVB/SVB-T neither unit SV-B, SVT-B nor TVI are included as supplied. 130x300x130mm (HxBxT) 5 kg Order number: FC009610
FC38502E-A

Dimensions: Weight:

Type: ABAB-TVT TVT LAN


60 product catalogue V1.2

VISOCALL PLUS

Datasheets

13.18

TV Interface
TV interface for controlling TV terminal, installed in the wall console or the connection box and consists of:


Caution: patient

Insertion slots for PTVT connection cable Connection for 24V power supply Connection for VCK-B2 Dimensions dependent on placement in the wall console for controlling unit TVT you will require in this instance handset PBG-TV (FC009604) with coiled connection cable. Order number: FC81456FC81456-

Type: TVI

13.19

TV Interface Interface standalone


TV interface for controlling unit TVT as per 13.18, however, as a standalone variant. In combination with this TV interface, the TV terminal can be operated without being connected to the VISOCALL PLUS system, and consists of:


Caution: patient

Insertion slots for TVT connection cable Connection for 24V power supply Dimensions dependent on placement in the wall console for controlling unit TVT you will require in this instance handset PBG-TVL (FC009608) with coiled connection cable. Order number: ED010714

Type: TVITVI-STA

13.20

Cable remote control for TVT/MMT


For the standalone variant of the TV terminal or the Multimedia terminal without using a TVI controller circuit board. Used as an operating component, for program search process and programming the TV terminal and the Multimedia terminal. Without nurse call, telephony and billing functions, consisting of:

coloured multifunctional keys (red, green, yellow and blue) On and off buttons for radio and TV On and off buttons for radio and TV menu as well as Teletext Arrow keys for changing program and setting volume as well as menu navigation Numerical keypad for direct entry of numbers includes coiled cable with high tensile strength and RJ45 connector (connection to RS485 interface on TVT or MMT) 218x60x25mm (HxWxD) plastic case in colour RAL 9010

Dimensions:

Type: RCRC-TVT

Order number: FC009609

61

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

14 Power supplies
For power supply within each type of system throughout the ward.

14.1 Power supply (In accordance accordance with hospital standards)


For use throughout the ward, whilst considering the particularly high input surge currents, in accordance with the relevant VDE, EN (EN61558 and EN60601-1) and DIN standards (DIN 0551), current and voltage stabilised, short-circuit resistant, Assembled in accordance with VDE0804/ level of protection II; Technical details: Power supply: Primary power consumption: Output: Output current/from cold start: Average continuous current: Peak current: Residual ripple: Insulation voltage: Ambient temperature: Load variation: Air humidity: Parallel operation: Dimensions: Weight: 230V/50Hz 6 A at full load 24 V= maximum 28A 15 A short circuit resistant 30 A 50mV at full load 3KV between input and output (parts checked) max. 40C at 15A 1A per C at ambient temperature max. 40C at 15A < 80% activated

241x130x88mm (WxHxD) 2,5 kg

Leakage current and circuit insulation voltage in accordance with EN60601-1 (DIN 750, part 1) Transformer in accordance with VDE 0551 Device earthed, with power switch and control lamp; including power cable and plug. In accordance with VDE0384 the power supply must be connected to its own electric current The primary electrical circuit earthing must be done using a 16A circuit-breaker with B type tripping characteristics. Type: DD-TOP500ME/1TOP500ME/1-ME Order number: FC008702

14.2 Cable for DD-TOP500/1TOP500/1-MED


Cable for power supply for connecting to 230V~ Lenght: 2,5m

Type: ZUB NG KAB

Order number: FG020231

62

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

14.3 UPS Module


UPS Module for power supply D-TOP500ME consisting of two sections: UPS module as a device for building into the distributor case, can be snap-fitted on to standard profile duct TS35 in accordance with EN50022 Battery module as a device for building into the distributor case, attached using 4 M5x8 screws (not supplied) Protection class III in accordance with EN60950 Safety: SELV classified in accordance with EN60950 Class of protection IP20 in accordance with DIN VDE 0470, 11.92 Cooling: Operating temperature: Current limiting: Mains operation: Battery operation: Battery module: Discharge time: Dimensions: Air convection Battery: +5C to +40C UPS: 0C to +60C using DC supply (e.g. D-TOP500ME: 20A) UPS module by circuit breaker approx. 120A dependent on temperature protected by a 25A flat fuse 30 min. at full range, accu for 7Ah (up to 20.8V; with a fully loaded buffer battery; IL=20A)

UPS Module: 200x125x80mm (WxHxD) Battery module: 175x170x126mm (WxHxD)

The battery module contains two maintenance-free lead storage batteries connected in series, each 12V (7Ah)

Type: DD-TOP BAT550 Type: DBATDBAT-2424-7Ah Type: DBATDBAT-2424-14Ah

Order number: FC008710 Order number: FC008711 Order number: FC008714

63

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

14.4 UPS Case


Complete UPS Case (conforming to VDE0834) consisting of: Steel case with lockable doors D-TOP 500/1-ME power supply unit (see item 14.1) Electronic module for controlling the UPS (see 14.3) Battery module for maintaining the supply voltage in the event of the mains power supply going down (see 14.3) Mini room terminal for indicating the power failure in the system Messages: Both faults (temperature sensor fault or battery fault) and the failure of the mains supply voltage are communicated to the rest of the system by means of the integrated mini room terminal. If a fault occurs, then it is forwarded to all components in the system and indicated at these components. If there is a mains supply voltage failure, then the system also receives a failure message from the mini room terminal. 230V/50Hz 6 A at full load 24 V= 1 hour at 14 A 35C 445 x 600 x 225mm (W x H x D) ca. 20 kg

Power supply: Primary power consumption: Output: Discharge time: Ambient temperature: Dimensions: Weight: Caution:

There is also the possible option of building in an additional battery module in to the UPS case. This add-on increases the battery capacity to 28Ah.

Type: VCPVCP-USV

Order number: number: FC008720

64

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

14.5 Power supply


Power supply for use in care homes and old peoples home, where the current hospital standards for power supplies are partially not applicable: Power supply Output: Output current: Input surge current: Fuse: Input rated current: Residual ripple: Ambient temperature: Load variation: Overvoltage protection: Parallel operation: Dimensions: Weight: 230V/47-63Hz +15%, -20% 24-28V (adjustable using the covered potentiometer) 20 A 33 A from 264V AC 10 A 5A < 100mV 0C to +70C 1A per C at ambient temperature max. 40C at 15A +/- 10% at 32V yes, up to 10 devices

220x124x102mm (WxHxD) 1.8 kg

Recommended cooling clearance: above/below 70mm each, right/left 25mm each All connection terminals can be easily reached from the front side of the device, furthermore PVC cable can be used for all the connections terminals, because they are on the bottom side of the cool area.

Type: SL20.101

Order number: FC008722

65

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

15 Installation accessories accessories


All materials which are used during the installation of a system which can be delivered in advance or separately for installation and stock reasons are listed here. These parts are also purchased and billed separately. Standard parts are marked by the symbol "*)", and they can also be obtained and provided elsewhere.

15.1 Switchbox *) (AT, RT, ZT, PT, ART, AW2, RAT, RDF, SVMSVM-K, ...)
For countersunk installation; made of plastic, flame retardant in accordance with DIN/VDE 0606 Part 1 /11.84; main body conforms to DIN 49030; suitable for parts in accordance with DIN 49200. Plastic part does not contain halogens. Dimensions: Type: U1 60 mm diameter, H=40mm, distance between device screws 60 mm Order number: FC88010FC88010-

15.2 Double switchbox *) (SVs, (SVs, SVM, STMs, VTXT)


For countersunk installation; made of plastic, flame retardant in accordance with DIN/VDE 0606 Part 1/11.84; main body conforms to DIN 49030; suitable for 2 units or 1 double unit in accordance with DIN 49200. Plastic part does not contain halogens. Dimensions: Type: U2 W=60 mm, D=40mm, H=142mm Distance between screws 60mm/2x 71mm apart Order number: FC88012FC88012-

15.3 Switchbox *) (AT, RT, ZT, PT, ART, AW2, RAT, RDF, SVMSVM-K, ...)
For cavity wall installation with mounting screws and device screws; made of plastic, flame retardant in accordance with DIN/VDE 0606 Part 1 /11.84; main body conforms to DIN 49073; suitable for parts in accordance with DIN 49200. The switchbox is available on request in a halogen-free variant. Dimensions: Type: H1 60 mm diameter, H=45mm, distance between device screws 60 mm Order number: FC88011FC88011-

15.4 Double switchbox *) (SVs, SVM, STMs, VTXT)


For cavity wall installation with mounting screws and device screws; made of plastic, flame retardant in accordance with DIN/VDE 0606 Part 1 /11.84; main body conforms to DIN 49073; suitable for parts in accordance with DIN 49200. The switchbox is available on request and upon special demand in a halogen-free version. Dimensions: Type: H2 W=68 mm, D=45mm, H=142 mm Distance between screws 60mm / 2x 71mm apart Order number: FC88013FC88013-

66

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

15.5 Installation Case (ST, STST-D, VDZT)


for countersunk mounting, with device screws for the terminal box frame; made of plastic, flame retardant in accordance with DIN/VDE 0606; with holes for attaching the connecting circuit board and guide rails for sub-circuit boards. Supplied with cover PZEK2. Plastic part does not contain halogens.

Dimensions:

140x242x65mm (WxHxD)

Type: ZEK2

Order number: number: FC88009FC88009-

15.6 Installation Case (ST, STST-D, VDZT)


for cavity wall installation, with device screws for the terminal case frame; made of plastic, flame retardant in accordance with DIN/VDE 0606 with holes for attaching the connecting circuit board and guide rails for sub-circuit boards. The switchbox is available on request and upon special demand in a halogen-free version.

Dimensions:

140x242x65mm (WxHxD)

Type: HZEK2

Order number: FC88008FC88008-

Note: Screws for devices in countersunk switchboxes (2 per single box, 4 per double box) as well as for connecting circuit boards in installation cases (4 screws each) are not included. The following are required: standard countersunk self-tapping screws with 3.2mm diameter, L = 15 mm, corrosion resistant in accordance with DIN50018.

15.7 Terminal Clip


for attaching screw-free clips to devices and connecting circuit boards

Type: HB

Order number: FC005998FC005998-

15.8 Removal tool


for removing the room terminal control unit (terminal case) from the case frame.

Type: AZ2

Order number: FC005999FC005999-

67

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

15.9 Soffit lamps


24V / 5W for room, direction and group signal lamps; Length (tip to tip) = 42mm, diameter 14mm

Type: Gd5Gd5-9 Type: Gd5Gd5-2 Type: Gd5Gd5-3 Type: Gd5Gd5-6 Type: Gd5Gd5-7

wh rd gn ye or

Order number: number: FL73309FL73309Order number: FL73310FL73310Order number: FL73311FL73311Order number: FL73321FL73321Order number: FL73330FL73330-

15.10

Connecting cable CAT5 (from DZT to ZI)


For the star formation cabling of the ward terminal to the control interface including the copper cores. Laying cable 4x2x0.8mm CAT 5 100MHz, twisted core pairs, foil and braid shielding, halogen free; plastic sheathing

Type: CATCAT-5

Order number: on demand

15.11

Ward bus cable


For the BUS line sections from terminal to terminal, including copper cores 1x2.5mm2 (for 24V= power supply), 1x2x0.6mm diameter stranded and x2x0.6mm diameter twisted pairs, shielded and with a shielded drain wire; all cores are collectively encased and with a shielded drain wire; with a plastic sheath (grey, ca. 9.5mm diameter; in Germany: blue) and blue (marking) inscription. The cable with the type no. VCK-2HF is halogen free. Type: VCKVCK-2 Type: VCKVCK-2 HF Order number: L224225607 Order number: L224225608

15.12

Room bus cable


For connecting the room terminals with the connection devices at patient beds, or with the service duct, designed for 3 beds, including copper cores. 5x2x0.6mm diameter stranded in pairs and 2x2x0.6mm diameter twisted pairs, shielded and with a shielded drain wire; with a plastic sheath (grey, ca. 9mm diameter; in Germany: blue) and blue (marking) inscription. The cable with the type no. VCK-B2HF is halogen free. Type: VCKVCK-B2 Type: VCKVCK-B2 HF Order number: L224001406 Order number: L224001407

68

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

15.13

ELAC Transmitter *)
for the connection of a program circuit throughout the ward to the riser circuits coming from the ELAC control centre; technical specifications: Primary voltage Secondary voltage Secondary power 100V ~ 2.5V ~ 0.6/1.25/2.5/5/10W;

with connecting ties and soldered connections

Type: RFUE Type: GAT5

Order number: FC005980 Order number: YY208786

15.14

Surface mounting case case for ST


for surface mounting, made of plastic (ABS, colour: RAL 9010) for connection of the connecting circuit board "VST" or "V-DZT" and for snap in the eletronic part "ST" or "AE-DZT" (the DOSENRAHMEN "DR-ST" is not required!).

Dimensions: 255x176x30mm (HxWxD)

Type: APAAPA-ST

Order number: FC008990

15.15

Double surface mounting case (for STM, SV, etc.)


for surface mounting, made of plastic (ABS, colour: RAL 9010) with 6 prepared cable inlets (10 and 16mm) and 4 screws for attaching the carrying ring.

Dimensions: 160x83x40mm (HxWxD)

Type: APAAPA-2

Order number: FC008992

69

product catalogue V1.2

FC38502E-A

VISOCALL PLUS

Datasheets

15.16

Single surface mounting case (for RT, AT, etc.)


for surface mounting, made of plastic (ABS, colour: RAL 9010) with 2 prepared cable inlets (10 and 16mm) and 2 screws for attaching the carrying ring. Dimensions: 86x83x40mm (HxWxD)

Type: APAAPA-1

Order number: FC008991

70

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

VISOTAX VISOTAX PLUS

71

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

General

General
In many hospitals the requirement for the provision of services for patients is constantly increasing. TV and radio as well as telephones are available, either free of charge or as a chargeable extra. For this reason, the competent specialist companies are called upon to offer new innovations and complete solutions time and time again. Schrack Seconet has created a solution with its VISOTAX PLUS solution, which not only contains the functions listed above, but also additionally allows billable internet access. The VISOTAX PLUS billing system is installed as an independent system, but can, however, also be combined the already familiar VISOCALL PLUS system. The patient handsets with telephony functions possess an integrated smart card reader. All services that are used are debited from the account which has been assigned to the patient using the ISO smart card. Schrack Seconet would also like to be able to offer innovative customer-oriented systems in the future and therefore hopes for the continued support from hospital decision-makers.

72

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

System Description

System Description
1 General
VISOTAX PLUS is a very flexible billing system. It can be customised to suit customer-specific requirements and wishes by means of simple programming. The greatest demand is placed on such a system by the billable services, which the hospital is able to make available to the patient. These services include, for example: Telephone billing TV billing for a basic fee (daily fee for 24 hours) TV billing based on a tariff model (billing per minute) Internet access based on duration charges (billing with billing interval to the second) There are different billing models for the billing of services (telephony, television and Internet access). The key to the system is the smartcard. It is used to identify the patient, and allows the patient to take advantage of the services on offer. Crediting accounts at the payment station is just an unproblematic as the corresponding debiting of the account after a phone call has been made, TV has been watched or an Internet access session. On leaving the hospital the card is surrendered at the payment station and the remaining credit on the account paid out again The type of billing required can be chosen for each patient. Basically there are two modes: pre-paid and post-paid billing (see below). PrePre-paid billing In most instances, this type of billing is preferable. The patient purchases a smartcard at the payment station and the billing system sets up an account for this smartcard. Then it is possible to credit this account with the desired sum of money. The patient then uses the desired services. Prior to leaving the hospital, the patient hands back the smartcard at the payment station and received the balance for his remaining credit there and then. By using this type of billing there is very little administrative effort required and even then it is restricted to system maintenance as well as filling and emptying the payment stations of money. PostPost-paid billing This type of billing does not require the smartcard account to be in credit when first making use of the available services. The post-paid billing system is primarily used, if the patient should not be burdened with making pre-payments. The patient either receives a smartcard either at the payment station or from a workstation and can then use all the services he wishes to. Shortly prior to leaving the hospital he allows his account to be billed and settles the outstanding sum of money. Tariff levels In order for VISOTAX PLUS to remain flexible enough, so-called tariff levels have been prepared for use in the system. The reason for this is varying charging for all charges that can be incurred. Up to 5 different levels can be pre-defined for each system. The levels may have differing levels for basic charges and duration charges as well as for the entering of value added tax. Analyses Analyses and financial statements All services which the patient has made use of can be traced at any time via the billing server. All telephone calls, all credits and debits, as well as TV and Internet access charges are logged and can be printed out at any time. The data remains saved for as long as has been configured in pre-programming. A data backup module allows all data to be archived. Faults The system concept allows for occasional faults to be displayed by pop-up windows on the servers monitors and on workstations. On which monitors these faults are to be displayed can be determined by means of programming and can be changed at any time.

73

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

System Description

1.1 Telephone billing


The very diverse range of requirements for the billing of telephone calls made by patients and the variety of telephone systems made by various manufacturers ensures that the area of billing of telephone calls can be a very comprehensive one. Basically, the billing of a telephone call occurs as follows: Telephone call without call termination when credit reaches 0 The patient has credited his account using the smartcard and is logged into the billing system. VISOTAX PLUS knows which physical extension the patient is at. As per the operating instructions, the patient presses the exchange key. The PINCODE for this card is entered and the patient receives a dialling tone, and thereby the opportunity to dial a telephone number. Once the call is finished the telephone system sends a billing record to the billing system. Based on this record, VISOTAX PLUS is able to charge the incurred telephone costs to the patient's account. Not all telephone systems offer the possibility of terminating a call using an available interface from an analogue extension once a pre-defined account balance has been reached. In light of this fact, it is possible to have a negative account balance when using this type of billing system, but due to the partial authorisation required by the extension this negative balance can be kept very low. Telephone call with call termination termination when credit reaches 0 The patient has credited his account using the smartcard and is logged into the billing system. VISOTAX PLUS knows which physical extension the patient is at. As per the operating instructions, the patient presses the exchange key. The PINCODE for this card is entered and the patient receives a dialling tone, and thereby the opportunity to dial a telephone number. As soon as the call is connected, the telephone system informs the billing system which number was dialled at what time of dial and using which PIN code. The billing system is then able to ascertain based on a chart and the dialling code number, to which zone this telephone call is being made. At the start of the call, it works out and determines the point at which the call is to be cut off. The telephone system can then alert the patient to the imminent termination of the call prior to the call being ended by means of a short tone. This type of billing is carried out by the interface which is described in chapter 2.x. (Telephone Systems). The patients account balance may not become overdrawn due to a telephone call under any circumstances. Caution: Not all telephone systems support the termination when account balance reaches 0" function, therefore in this instance it is essential that discussions are held with the relevant firms involved. Number portability By using the log-in process (by pressing a button for the patient) the billing system will be informed at which physical extension the patient is located. It is possible for VISOTAX PLUS to carry out the number portability function using the programming interface described in chapter 2.y. Regardless of where the patient is then moves to during his/her hospital stay, the patient always remains contactable on the same internal call number for external callers. The system internally forwards all calls for this virtual telephone number to whichever physical phone number from which the patient last logged on.

74

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

System Description

1.2 Television billing


TV basic fee billing (only for TV terminals terminals and room TV sets) The patient has the opportunity to activate his television set for 24 hours. For this process, the hospital administration can demand a so-called daily fee or basic fee. The patient has credited his account using the smartcard and is logged into the billing system. VISOTAX PLUS knows which physical extension the patient is at. In accordance with the operating instructions, the patient would like to activate his TV set by making a phone call. The billing server checks whether the account 's balance based on its PIN code and calls the patient back at his/her extension. The patient finds out via the voice processing system from the billing server, that his/her TV set can be operated freely for 24 hours. After this period has expired, the TV set is once again blocked, and the patient has the choice whether he wishes to watch TV for another 24 hours or not. TV timetime-based tariff model (only for TV terminals or Multimedia terminals) A more detailed billing mode is one whereby charges are debited from the patient's account based on a basic fee and a time-based tariff. A TV billing tariff model which is saved on the server, allows per minute TV billing. The patient has credited his account using the smartcard and is logged into the billing system. VISOTAX PLUS knows which physical extension the patient is at. In accordance with the operating instructions, the patient wishes to use his/her TV set. If he selects a channel which is liable to charges, then the charge is debited from the patients account. If there is no credit remaining in the account, then a message will appear on the TV terminal informing the patient that he is no longer able to operate the television. The billing server receives data from the patient TV terminal (TVT) on a permanent basis. This data includes the pin code, date, time and channel at which the television terminal was showing pictures. Based on the billing table, the server knows exactly how much must be booked from the relevant account. As soon as the channel is changed, then the server also recognises that this has happened and starts the billing process again. The TV billing model is so flexible, that it is not only possible to define groups of channels but also to define billing groups. These billing groups can then be combined in every possible way with the channel groups.

75

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

System Description

1.3 Internet
Internet timetime-based tariff (only for Multimedia terminal) The billing for internet access is done in a similar fashion to television billing. The patient has credited his account using the smartcard and is logged into the billing system. VISOTAX PLUS knows which physical extension the patient is at. In accordance with the operating instructions the patient would like to surf the Internet. The Internet server receives the information about how long the patient has surfed the Internet for using his/her Multimedia terminal via the LAN connection. As soon as the Internet access session has been terminated, the Internet server sends the billing system the relevant information to that VISOTAX PLUS can debit the costs incurred from the relevant account. If the accounts credit has been used up, then the patient is no longer about to start up the Internet browser, and a message also appears on screen with the information that the user is no longer entitled to Internet access.

1.4 Services for Staff


VISOTAX PLUS also offers the possibility, not just to offer patient services, but also to bill private phone calls by staff members, in one system. Hospital employees either receive a similar smartcard to the patients, or when dialling private phone numbers, they use their PIN code as a pre-dial code. Digital telephony devices have speed dialling memory keys, with whose help it is no longer necessary to have to enter the whole number. The flexibility of the system can be seen in every kind of application. Even in the deployment of staff member billing. The available tariff levels can also be used for staff members. All reports as well as being able to trace all debits and credits at any time as well as expenses incurred can also been seen, in the same manner as they are in normal patient billing.

76

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

System Description

Hardware

A standard PC with the relevant hardware (see p.9) is used in the VISOTAX PLUS system. The PCs can then be used both as servers as well as workstations.

2.1 VISOTAX PLUS Server


Each system to be installed requires a server. The server is the central location upon which the databases are stored. The server serves all the workstations and payment stations integrated into the billing system via the available LAN, or a LAN that is installed separately.

2.2 VISOTAX PLUS Workstation


The number of workstations to be used within the system can be freely determined and is based entirely on the needs of the customer.

2.3 TV Server
The TV server acts as an interface between the VISOTAX PLUS Server and the TV hub. It is used when the TV terminals and Multimedia terminals which have been installed are to be billed using a channel-based and timebased billing model.

2.4 Internet Applications Server


An additional software package is installed on the Internet Server listed in section 12.10, which transfers the logout and logout times for Internet access for each individual patient via LAN to the VISOTAX PLUS server.

2.5 Payment Station


without Credit Card Interface The electronics and the embedded PC as well as the necessary components (banknote acceptor, coin checker, coin hoppers, receipt printer, smartcard dispenser, smartcard writer, banknote dispenser) are installed and securely housed in a robust armour-plated steel case. The payment station can be used throughout Europe, and is equipped to read all Euro denominated banknotes and coins in circulation. For export to other countries using a different currency, it is necessary to check whether, and how the necessary modifications can be made. The embedded PC has a LAN interface which is used to connect it to the server. The embedded PC has no hard drive and loads the operating system in to the cash register directly from the server. With credit card interface The payment station mentioned above also offers a credit card interface as an optional extra. The patient thereby no longer necessarily requires cash in order to make a payment into his/her account, this being carried out via credit card in this instance. Since there can be several operators of credit card interfaces in every country, it is necessary to check out the various possibilities for extensions for this option.

2.6 Central POS Server


The central POS server serves the payment stations with their boot software via LAN. It also acts as a communications interface between the VISOTAX PLUS billing server and the individual payment stations.

77

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

System Description

Software The installed software must perform various tasks. On the one hand it is used to receiving and processing patient and/or staff data as well as the correct assignment and debiting of all services that have been used, as well as one the other hand being used for setting the system and interface parameters. WIN NT4.0 (Service Pack 5) or Windows 2000 (Service Pack 2) acts as a platform for all computers integrated into the system. The LAN is also defined using one of the two operating systems. The collected data is not just centrally managed and saved on the server, but is also served to every workstation and cash register as required. Physically the server is not just connected to the LAN, but is also connected to the telecommunications system.

2.7 Telephone system


Standard interfaces such as the billing data interface (GDE) and the programming interface are connected to the server via the RS232 port. For special functions, e.g. call termination when account balance reaches 0 and number portability (every patient is assigned a virtual number on which he/she can be reached anywhere in the building) a CTI interface or a LAN interface in the telecommunications network are required in most instances. This must, however, always be clarified in the presence of the relevant contact person from the telecommunications company, because standard configured Hardware is not always deployed. Telecommunications Telecommunications system billing data interface The server receives all billing records which occur within the system via this interface and filters out the relevant PIN code phone calls which it requires. Based on the assignment of PIN codes the server is able to bill call charges to the correct patient account. The telecommunications system, however, only sends the call record after the telephone call has ended. The last call may in certain circumstances lead to a negative account balance. The CTI interface provides workaround for this problem (see below). Telecommunications system programming interface Basically patient telephones are barred and only cleared for making calls to emergency numbers. Upon being assigned to a bed, the patient must first of all log-in into the billing system. This is done by using the check in function, either on patient handset PBG-T or Chiptel 190 payphone kiosk. The server now knows at which physical extension the patient is logged in at and grants the relevant privileges to this extension device based on the patient's current account balance (depending on customer wishes and account balance local, national or international calls). Activations, privileges, deactivations are carried out using this interface in this way. For some telephone systems, it is also possible to use so-called number portability via this interface. The patient logs in at his/her new extension each time after having been moved and keeps the same internal number as far as external calls are concerned, on which he/she can be reached throughout the entire hospital. CSTA (TAPI or TSAPI) for the Telecommunications System The term CSTA means Computer Supported Telecommunication Applications and is also often mentioned in close association with the term CTI. Computer Telephony Integration is a general term. This interface is basically used in telecommunications systems, when a foreign PC system wishes to connect to the telephone system. This type of interface is necessary for special billing system functions. As described above, the server always only receives the billing records once the telephone call has been ended. A negative account balance in certain circumstances is unavoidable. However, there is now also the opportunity to receive a brief record from the telephone system via the so-called CSTA immediately after the call has been connected. The server is able to calculate the amount to be billed in advance based upon this information which is received, and is able to then terminate the telephone call. Some telecommunications systems also support the previously mentioned number portability function using this interface.

78

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

System Description

Telecommunications system server already available Some telephone systems providers do not want to allow foreign systems to connect to the programming interface for security reasons. Via the programming interface it is possible, in principle to carry out all the available commands listed in the specification, even if they are not necessarily requires by VISOCALL PLUS. Various faults can therefore occur in the telecommunications system as a result. In order to keep the risk of this happening as low as possible, the operators have made a computer application available. This PC may use the widest variety of different systems: Application Link Communication Link BCS Server Hi Path MD110 (ERICSSON) ALCATEL 4400 (ALCATEL) INTEGRAL 55 (TENOVIS) HICOM (SIEMENS)

The PC regulates communications between both foreign systems and VISOTAX PLUS is able to tailor the specifications of its interface accordingly. It can also be ascertained based on this specification, which functions can be carried out from the PC. The basis premise is: For all future projects and also possibly for some currently hitherto unknown software applications, specifications and software descriptions must be obtained from telecommunications systems providers. We will then carry out the necessary customization.

79

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

System Description

The Software

Based upon the variety of demands placed upon VISOTAX PLUS, it was essential to implement the concept on a modular basis. The number of extensions used in the system is irrelevant. The modules described below are optional and can be obtained in the form of licenses.

3.1 Single license modules


Patient management Application for the server or for a workstation. All patient information, e.g. personal information, account balance, where they have been moved to etc. can be viewed via this overlay. The software provides a complete overview of the patient as well as displaying call information and the possibility to log the patient in and out, as well as the possibility to analyse all patient records, as well as smartcard operation. Staff management The VISOTAX PLUS billing system is not only deployable for patients, but also for employees or other companies. For this overlay, the same functions are available as previously described above in the section about patient management. Electronic Phonebook VISOTAX PLUS offers an optimal opportunity for creating an electronic phonebook. This is, however, only possible, if patient records are personalised. In an anonymous system, it is possible to find extensions, but no names can be found for them.

3.2 Network modules


Charges receiver The charges receiver module is responsible for the billing data interface between the server and the telephone system. It is used to accept and supply phone call data from the telecommunications system. Interface program for data transfer If a server is networked with one or more workstations, then this module takes care of the necessary data transfer using the TCP/IP protocol. Television billing - basic fee VISOTAX PLUS enables a daily / use-related basic fee for using the room TV set, the patient TV Terminal or the Multimedia terminal. If this software module is integrated into the system, then a flat rate sum is defined for each patient class, which is debited from the patients account if the device is used. This type of TV billing differs from the time and channel fee billing model. Discount levels The hospital's administrators also have the opportunity to offer discount levels which benefit so-called "frequent callers". Two levels are available per patient class. Once a certain frequent caller sum has been reached, a predefined percentage reduction is applicable. Of course it happens time and time again, that patients have to stay in hospital for a longer than average period of time. In such instances, it is possible to apply discount levels to currently outstanding flat rate fees. Once a certain number of days have been exceeded, then a predefined percentage reduction is enforced.

80

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

System Description

3.3 Cash register modules


Payment station integration In a normal case, the controller software is installed on the billing server. It runs in the background, and collates all data from all the payment stations in the network. If there are more than 5 payment stations installed, it is necessary to obtain a central POS server, which takes over the POS tasks from the billing server, so that the billing server is not overloaded. Language modules The payment stations user interface is in German as a default. Dependent on a customers requirements, other languages can also be installed, such as English, French, Italian etc. To enable this, the additional languages required will be included in the database.

3.4 Accessory modules


Smartcard integration In order to be able to read the smartcard on the server or at one of the workstations, a keyboard is required in which a smartcard reader/writer is integrated or an external chipcardreader. There are two interfaces available, first the serial one (RS232) and second the USB 2.0 (seperate chipcardunit), you can use one of them. The module is able to automatically detect the interface of the smartcard reader is connected to. Remote maintenance module The system offers complete access to all PCs connected to the billing system for maintenance and testing purposes via the remote maintenance module, including the server, the workstations and the embedded PCs in payment stations. Backup module Due to the large quantity of data involved, it is essential to carry out orderly backups. The databases are permanently in an online state and must therefore be closed and duly backed up. This is not possible with traditional backup programs. The backup module saves the relevant data on a removable data carrier which has been specially prepared for the hardware.

3.5 Telephone exchange


Connection to a telecommunications system VISOTAX PLUS can be customised to accommodate any PABX system, on the condition that the telephone exchanges hardware contains RS232 serial interfaces. The module ensures the faultless communication between both systems. The following telephone systems have been adapted to would with the billing system. ERICSSON MD110 SIEMENS HICOM 300/HIPATH READY 4000 PHILIPS SOPHO CORAL TENOVIS INTEGRAL 55 If a PABX which is not listed is being deployed in a project, then we develop the relevant interfaces and/or customisations in conjunction with the relevant telecommunications system manufacturer.

81

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

System Description

The Components

Using the aforementioned components it is possible, in practice, to create any type of system imaginable. The individual settings are carried out using a pre-defined password level in the patient management overlay. VISOTAX PLUS offers the user a carefully designed and clear overview.

4.1 The VISOTAX PLUS Billing Server


The server is the heart of the VISOTAX PLUS system. It saves all collected data in the relevant databases. All data is archived on the relevant data carriers using the data backup module. All workstations and payment stations have the appropriate access to the data which is relevant for them. Communication with the telecommunications system and possible foreign IT systems is also included in the VISOTAX PLUS servers functions. Additionally, if required, the server also manages the account balance announcements as well as various announcement texts using the Voice Processing System. In the event of servicing, full access is available to all IT components in the system via remote maintenance.

4.2 VISOTAX PLUS Workstation


From the workstation it is possible to access and modify and/or delete the data for all patients in the VISOTAX PLUS system. The entire smartcard operation process also takes place using this software interface. All data can be analysed using a wide range of filters. As many workstations as are required can be used within the system. The system administrator is able to define user/password profiles for as many VISOTAX PLUS users as is require from the workstation. This is not only possible at the start when installing the system, but is also possible whilst the system is operational. During the programming of the system, which fault messages and maintenance messages should appear at which workstations is also defined.

4.3 TV Server
With help from the TV Server, VISOTAX PLUS is able to bill TV services according to channels and time watched to the minute. All data about changes of channel are sent from the TV hub to the TV server, and are filtered accordingly to be sent to the billing server. The billing server then bills the user exactly to the minute for the TV fees incurred according to the billing model.

82

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

4.4 The Server for the payment station


When installing systems including payment stations a central POS server is deployed, since the level of data traffic between the cash registers and the billing server is very high. As many payment stations can be used as required.

4.5 The Payment Station


Up to 32 payment stations can be installed in a system. An embedded PC is installed in the payment station, which functions as an interface between the cash registers electronics and the server. The payment stations user interface is easy to operate and is available in various language versions. The service menu icluded in the software can be reached by entering a password. In this menu is it possible to fill up the coin hoppers and the smartcard reservoirs as well as to empty the banknote checker.

83

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

Datasheets
1 Hardware
The following hardware is used during the installation of the VISOTAX PLUS billing system.

1.1 Billing Server


Server for data transer and data storage, consisting of: Minimum system requirements:

Intel P4 Celeron 1.3 GHz processor 256 MB DDR DRAM min. 40 GB HDD min. 48x CD-R LW FDD 3.5 1.44MB Onboard i845G graphics and soundcard Onboard Intel 10/100 LAN serial interfaces (2 onboard, 2 PCI) Smartcard keyboard and mouse (including mousepad) Windows 2000 professional edition maximum power consumption 200W at 230V~

Dimensions: 444 x 205 x 500 mm (H x W x D) Weight: ca. 15 kg as optional extras, there are: 250MB ZIP drive Internal 56Kbps modem

Caution: If patient Internet access is also to be billed, then the applications server described in the VISOCALL PLUS chapter (see 12.11) is also required. Type: VTPVTP-HWHW-SRV Order number: FC007300

1.2 TV Server
Server for data transer and data storage, consisting of: Minimum system requirements:

Intel Pentium 2,8GHz processor RAM: min. 512MB HDD 80GB, DVD-ROM LAN Intel 10/100/1000 onboard, RJ45 connection VGA Grafikadapter (onboard or PCI) Keyboard and mouse

Type: VTPVTP-HWHW-TVS

Order number: FC007360

84

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

1.3 Central Server for payment station


Server for payment station boot process via LAN, consisting of: Minimum system requirements:

Intel Pentium 2,8GHz processor RAM: min. 512MB HDD 80GB, DVD-ROM LAN Intel 10/100/1000 onboard, RJ45 connection VGA Grafikadapter (onboard or PCI) Keyboard and mouse

Type: VTPVTP-HWHW-KS

Order number: FC007370 FC007370

1.4 Workstation
Workstation for editting all patient information, consisting of: Minimum system requirements:

Intel Celeron 1.3GHz processor 256 MB SDRAM min. 20 GB HDD min. 48x CD-R LW FDD 3.5 1.44MB Onboard i845G graphics and soundcard 56Kbps Modem 10 MBits LAN connection 2 serial interfaces (RS232) 2 x PCI slots 1 x AGP slot Smartcard keyboard and mouse Windows 2000 professional edition VISOTAX PLUS software package maximum power consumption 200W at 230V~

Dimensions: 361 x 196 x 350 mm (H x W x D) Weight: ca. 10 kg Type: VTPVTP-HWHW-WS Order number: FC007310

1.5 Laser Printer


For printing out group and individual invoices as well as analysis reports Parallel port for PC Connection ~230V Type: Drucker
Order number: on demand

85

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

1.6 ZIP ZIP Disk Drive


Hardware for reliable backups of data generated by the VISOTAX PLUS system (phone call data, patient data, settings, tariff data, fee data etc.)

Type: VTPVTP-HWHW-ZIP

Order number: FC007312

1.7 4 Channel Voice Processing System


PCI card for installation in the VISOTAX PLUS server, wirh speech processing system for account balance announements as well as possible login / logout texts.

Type: VTPVTP-HWHW-VPS4

Order number: FC007314

1.8 Keyboard with chipcardreader


PC keyboard mit an integrated chipcardreader for connection to the PS2.

Type: CHCCHC-KEYB

Order number: FC73100--FC73100---

1.9 Chipcard unit


External chipcard unit for connecting to USB2.0.

Type: ChipChip-USB

Order number: FC73100-FC73100--A --A

1.10 VGA Monitors


VGA colour monitor for use with server or workstation.

Type: Monitor

Order number: on demand

86

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

Software Modules

The following software modules are available based on the requirements of the operator.

2.1 Patient Management Module


Patient management module can either be installed at a separate workplace or on the server, and is intended for the following functions:

Admission and discharging of a patient Logging in and logging out of a patient at an extension Debiting and crediting a patient account Deleting recently discharged patients Writing to the smartcard using the smartcard keyboard Assigning the smartcard to a specific patient account Setting the 5 different patient classes Separate way of setting charges for each patient Analysis of call data Printing out invoices

Type: VTPVTP-SWSW-PAV

Order number: FC007301

2.2 Staff Management Module


The module is similar in terms of its functions to the patient management module, as is available as an optional extra.

Type: VTPVTP-SWSW-PEV

Order number: number: FC007302

2.3 Television billing - basic fee


For billing for a usage / daily flat rate fee for using the room TV set, the patient TV terminal and the multimedia terminal. One daily rate is defined for each patient class.

Type: VTPVTP-SWSW-TVG

Order number: FC007316

87

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

2.4 Electronic Phonebook Module


Optional Module as an extension of personalised patient and staff management. Requires personal information to be stored.

Type: VTPVTP-SWSW-ETB

Order number: FC007315

2.5 Discount levels module module


This module allows VISOTAX PLUS the opportunity to offer discount levels for frequent callers and patients who have a long stay in hospital.

Type: VTPVTP-SWSW-RAB

Order number: FC007317

2.6 Charges Receiver Module


This module allows charging data to be entered. The VISOTAX PLUS server receives all call information from the telecommunications system via the RS 232 serial interface. Since VISOTAX PLUS does not require all the data available, the system filters and processes only the data which is relevant.

Type: VTPVTP-SWSW-GDE

Order number: FC007303

2.7 Data Transfer Module


The server makes the necessary data available to all workstations within the system. This is either done via a separate LAN, or there is also the possibility to use the internal network.

Type: VTPVTP-SWSW-DT

Order number: FC007304

88

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

2.8 Smartcard integration module


Software drivers for the smartcard keyboards mentioned in 1.8and 1.9

Type: VTPVTP-SWSW-CC

Order number: FC007305

2.9 Remote maintenance module module


The remote maintenance module allows support technicians to enter the system from outside up to the cash register user level, and to thereby offer rapid and reliable support in the event of a system fault or failure.

Type: VTPVTP-SWSW-FW

Order number: FC007306

2.10 Data backup module


The continuous collection of data by the billing system necessitates easy and appropriate data backup. This module prevents possible data loss and saves all the data on a ZIP drive which has been pre-configured to suit the hardware (see 1.6)

Type: VTPVTP-SWSW-ZIP

Order number: FC007307

2.11 Telecommunications System Customisation Module


Since the necessary interfaces for telephone systems differ from one manufacturer to another, VISOTAX PLUS uses this module to adapt itself to the relevant telephone system.

Type: VTPVTP-SWSW-TK

Order number: FC007308

2.12 Internet Module


This module is for accouting the internet surfing time. The billing for the internet usage depends on the settings from the patient classifications. If there is too less money on the account, the access will be denied.

Type: VTPVTP-SWSW-IG
89 product catalogue V1.2

Order number: FC00731 FC007319


FC38502E-A

VISOTAX PLUS

Datasheets

Hardware Cash Register

For low-maintenance VISOTAX PLUS operation there are various types of payment stations available.

3.1 Standard payment station


User-friendly payment station for reduction of the amount of management required, for opening, crediting, displaying and closing a smartcard account as well as pay out remain account balances. When opening an account, a smartcard will automatically be issued against a deposit, and the smartcard will be sucked in when the account is closed, consisting of:

Solid sheet steel case (grey) for screwing onto mounting frame, with a lockable door with a security lock and with 4 retaining clips for increased security 10.4 TFT colour display (resolution 640x480 pixels) optional multilingual user interface operator assistance via 8 interactive function keys Banknote checker for recognition of up to 4 banknotes (5/10/20/50) Coin checker for recognition of 6 denominations of coin (0.05/0.10/0.20/0.50/1.00/2.00), of which alternatively three denominations can be accepted. Accepts 3 chosen denominations of coin with automatic coin circulation Combined mechanical smartcard issuing and redemption unit with integrated reader and writer, for up to 443 smartcards. Thermal receipt printer (58 mm width paper roll) Wide change return tray with transparent protective flap for receiving change and receipt. Centralised configuration Maintenance messages are automatically transferred Embedded PC with operating system, software and LAN connection for connection to central billing system or POS server. Remote maintenance possible Connection ~230V 10Mb LAN RJ45 connection 90 kg 1000x580x340 mm (HxWxD)

Weight: ca. Dimensions:

Type: VTPVTP-KA

Order number: FC007410

90

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

3.2 Payment station with credit card interface (Austria)


User-friendly payment station for reduction of the amount of management required, for opening, crediting, displaying and closing a smartcard account as well as pay out remain account balances. When opening an account, a smartcard will automatically be issued against a deposit, and the smartcard will be sucked in when the account is closed, consisting of:

Solid sheet steel case (grey) for screwing onto mounting frame, with a lockable door with a security lock and with retaining clips for increased security 10.4 TFT colour display (resolution 640 x 480 pixels) optional multilingual user interface operator assistance via 8 interactive function keys Integrated Austrian credit card and debit card interface for cash-free money transfer in to the VISOTAX PLUS account, for which purpose an ISDN S0 connection is included Banknote checker for recognition of up to 4 banknotes (5/10/20/50) Coin checker for recognition of 6 denominations of coin (0.05/0.10/0.20/0.50/1.00/2.00), of which alternatively three denominations can be accepted. Accepts 3 chosen denominations of coin with automatic coin circulation Combined motorised smartcard issuing and redemption unit with integrated reader and writer, for up to 443 smartcards. Thermal receipt printer (58 mm width paper roll) Wide change return tray with transparent protective flap for receiving change and receipt. Centralised configuration Maintenance messages are automatically transferred Embedded PC with operating system, software and LAN connection for connection to central billing system or POS server. Remote maintenance possible Connection ~230V 10Mb LAN RJ45 connection

Weight: ca. Dimensions:

90 kg 1000x580x340 mm (HxWxD)

Type: VTPVTP-KAKA-KIA

Order number: FC007420

3.3 Payment station with credit card interface (Germany)

Type: VTPVTP-KAKA-KID

Order number: on demand

91

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

3.4 Installation Installation frame


Coated sheet steel frame for affixing to the wall for installation of payment stations.

Weight: Dimensions:

ca. 10 kg 1000x580x20 mm (HxWxD)

Type: VTPVTP-KAKA-MR

Order number: FC007400

3.5 Floor stand


Sheet steel enamel coated floor stand for free-standing installation of payment stations, to be fastened to the floor using a high performance anchoring unit.

Weight: Dimensions:

ca. 15 kg 770x580x300 mm (HxWxD)

Type: VTPVTP-KAF

Order number: FC007401

92

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

Software Cash Register

For controlling payment stations as well as for multilingual user interface, the following software modules are available:

4.1 CashConfig Interface Application


This software module is installed on the billing server or the central POS server and is used to configure, as well as being an interface to, payment stations. The software includes also the bootserver (software for booting the payment station)

Type: VTPVTP-SWSW-CC

Order number: FC007371

4.2 Payment station connection


Software module for installation on the billing server. This module handles communications between the billing server and the central POS server.

Type: VTPVTP-KIK

Order number: FC007321

4.3 Language modules


The multilanguage module is used in hospitals with patients of international origins.

Type: VTPVTP-SWSW-L

Order number: on demand

93

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

TV Interfaces

For the various billing methods of TV charges, there are various TV Interface controller units available:

5.1 TVI standard


Using this TVI interface it is possible to bill the patient for the use of the room TV set or the Patient TV Terminal using a daily fee. This controller user can only be used in conjunction with the VISOCALL PLUS nurse call system.

Type: TVI

Order number: FC81456FC81456-

5.2 TVI stand alone


Using this TVI interface it is possible to bill the patient for the use of the room TV set or the Patient TV Terminal using a daily fee. This variation can be used without VISOCALL PLUS.

Type: TVITVI-STA

Order number: number: ED010714

5.3 TVI deluxe


With this TVI interface, it is possible to bill patients for use of the Patient TV Terminal using time and channel-based TV chargings. This variation requires the installation of a TV hub and a TV server.

Type: TVI TVIVI-LUX

Order number: ED010713

94

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

5.4 Connection Device


This connection device has a special interface for daily flat rate billing for room TV sets.

pole RS485 connection cable (50 cm long)

Type: SVTSVT-BZTV

Order number: FC008304

5.5 TV Hub
Interface between TV Server application and TV terminals and/or Multimedia terminals for data acquisition, compression and transferring to the billing system, consisting of:

Sheet steel case which can be locked using a key lock for connection of a maximum of 256 TV terminals or Multimedia terminals Power supply 230V~ with cold connector for connection to the power line 19 rack contains: -) 230V~ power supply -) Slots for a maximum of 8 slide-in cards each with 32 connections (TVT/MMT) pin SUB-D connector for connection to the TV server (RS422) Possibility to connect an additional TV hub Blue metal case for surface installation in electricity distribution case Ambient temperature: 0C to +50C Relative Air Humidity: 5-95% without condensation 600 x 445 x 225mm (H x W x D) ca. 15kg

Dimensions: Weight:

Type: TVH

Order number: FC009611

5.6 TVNI32 pushpush-in card


The TV hub can control up to 32 TV terminals using this push-in card. Up to approx. 8 push-in cards can be used simultaneously in each TV hub.

Connection strip for 32 TV terminals

Type: TVNI32

Order number: ED010711

95

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

5.7 Adam Converter (RS232 to RS422/RS485)


The Adam Converter is required for converting the TV servers serial interface (RS232) into the interface (RS422) used by the TV Hub. Plastic case with:

Connection for 9 pin SUB-D female connector (RS232) Connection for connection strip (RS485 and RS 422)

Type: ADAM 4520

Order number: FG020212

5.8 Power Supply for Adam Converter Converter


This power supply with plug is used as the power supply for the Adam Converter. Plastic case with:

2 pin connection for a 12V DC load. 350mm connection cable Maximum output current 2.5A, stabilised Wattage: 15W 165x65x40mm (HxWxD) without plug 165x65x75mm (HxWxD) with plug

Dimensions:

Type: NE 109

Order number: 73827

96

product catalogue V1.2

FC38502E-A

VISOTAX PLUS

Datasheets

Accessories

The smartcard serves as a key for access to VISOTAX PLUS services.

6.1 Smartcard
Standard smartcard in accordance with ISO standard 7816. It acts as the key to VISOTAX PLUS. With the smartcard, the patient has access to all services offered in the system. The smartcard can be printed with any graphic (in jpeg format) on both sides using 4 colour printing.

Type: VTPVTP-CK2x4C

Order Order number: FC007830

97

product catalogue V1.2

FC38502E-A

VISO-OPT PLUS

VISOVISO-OPT PLUS

98

product catalogue V1.2

FC38502E-A

VISO-OPT PLUS

System Description

System Description
1 Characteristic System Properties
The VISO-OPT PLUS emergency call system enables people requiring assistance to raise the alarm at a central location within a building or building complex. The system can, for example, be deployed in the following areas: Bathroom emergency calls in hotels, emergency calls for disabled toilets in public buildings, schools etc. or also for emergency calls for changing room cubicles in out-patient clinics and doctors practices.

1.1 Standards
Presuming that established VISOCALL PLUS call components (RT, ZT and PT) have been installed in the call inputs for VISO-OPT PLUS, VISO-OPT PLUS adheres to the following currently valid standards and regulations: VDE 0834 Part 1 area of application A

1.2 Maximum Security


Self monitoring Self-monitoring of the data circuits guarantees operational security. A fault is displayed as applicable at the base terminal. Safety features Automatic call reminders, integrated into the system prevent calls for being deleted.

1.3 Basic Installation


Infinitely variable system construction A base terminal and the relevant call device connected to one of the four call inputs form a functional system. The system can then be expanded on a modular basis. If more than 4 call inputs are required, up to 15 extension terminals (each with 8 call inputs) can be connected to the base terminal. Consequently there are a maximum of up to 124 call inputs available. If required, a complete terminal unit can also be installed in parallel.

1.4 Optimal concept for devices


Well thought out components are the mark of VISO-OPT PLUS devices concept: Base terminal For installation in a double countersunk case or surface-mounted case (vertically or horizontally) for use as a basic unit. Extension terminal For installation in a double countersunk case or surface-mounted case (vertically or horizontally) for use as a extension unit. Call and cancel buttons Even various VISOCALL PLUS call components can be combined with VISO-OPT PLUS. Signal lamps VISOCALL PLUS signal lamps can be used for displaying the local call location. Power supplies A 24V= power supply, with a maximum power supply of 2A is available for supplying the basic terminals and extension terminals with power. For calculation of power supply requirements the following applies:
99 product catalogue V1.2 FC38502E-A

VISO-OPT PLUS Fully equipped basic terminal (4 soffit lamps): 0.98A with 100% concurrence Fully equipped extension terminal (8 soffit lamps): 1.86A with 100% concurrence

System Description

Accessories Accessories, such as countersunk cases and surface mounted cases, can be found in chapter 14 of the VISOCALL PLUS section.

100

product catalogue V1.2

FC38502E-A

VISO-OPT PLUS

System Description

The types of system

2.1 Centralised Systems


The basic terminal, which is installed in a central location, offers the user a complete overview for all call locations. If a call is triggers, the user can either delete the call from this central location or from where the call originated from: this can be set using the DIL switches.

2.2 Combination systems


If a parallel panel is installed in addition to the basic terminal, then it may be up to 1200m away from the basic terminal. Call cancellation can be blocked from there or activated; this can be set by means of DIL switches.

The system functions

3.1 Call display


If a call is triggered from a call device which is attached to one of the call inputs, then an alarm signal will sound at the basic terminal. The relevant control LED corresponding to the call location will also be lit up on the terminal.

3.2 Cancel cancellation


The call can be cancelled in two different ways: By pressing the relevant button at the basic terminal or extension terminal (call cancellation must be activated) By pressing the cancel button from the place where the call was made (call cancellation at the terminal must be disabled)

3.3 Buzzer mute control


The basic terminals buzzer can be switched to mute by pressing a button. If the call is not deleted within two minutes, the alarm signal will sound again.

3.4 Faults
Since the VISO-OPT PLUS system is an emergency call system, the quiescent current of all call inputs is monitored, however, only when used with the VISOCALL PLUS call button, pneumatic button and pull button. In operating conditions this means that a fault is announced immediately, as sound as the call circuits and/or the call devices are damaged or disconnected (due to a wire break or a short circuit). The control LED for a fault lights up and the buzzer sounds. There is also the possibility of transferring the announcement of the fault to other systems, by using the fault relay.

3.5 Group call relay


A group call relay is integrated into the basic terminal. As soon as a call is triggered, the call can be displayed externally or be connected via this relay.

101

product catalogue V1.2

FC38502E-A

VISO-OPT PLUS

Datasheets

Datasheets
1 Terminals
For the centralised displaying of calls from all call locations within the system.

1.1 Base terminal


Base terminal, as a central location for all attached call inputs, to be installed horizontally in a standard double installation case, consisting of:

A membrane keypad with: - 4 cancel buttons including control LEDs - 1 buzzer acknowledgement button - description tags Electronic audible alarm voltage-free group call output voltage-free group fault output Green operation LED Yellow fault LED Connection clips for cal components and extension terminal

Dimensions: incl. covering panel 160x83x13mm (HxWxD) in colour RAL 9010 Type: VOVO-BT Order number: FC008950

1.2 Extension terminal


The extension terminal acts as an extension to the basic terminal, when more than four call locations are installed in the system. For horizontal installation in a standard double installation case, consisting of:

A membrane keypad with: - 8 cancel buttons including control LEDs - description tags Connection clips for cal components and extension terminal incl. covering panel 160x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008951

Dimensions:

Type: VOVO-ZT

102

product catalogue V1.2

FC38502E-A

VISO-OPT PLUS

Datasheets

Connectable components

VISO-OPT PLUS offers the optimal solution as well as providing integrated quiescent current monitoring in conjunction with VISOCALL PLUS components.

2.1 Call button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

1 call button (red, marked with a nurse symbol) on a membrane keypad with 2 control LEDs, finder light included 1 connection panel with screw-free clips; incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008400

Dimensions: Type: RT

2.2 Pull button button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

Membrane with a control LED, finder light included 1 connection panel with screw-free clips; including 2m cord with grip incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008410

Dimensions: Type: ZT

2.3 Pneumatic button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

Membrane with a control LED, finder light included 1 connection panel with screw-free clips; incl. 2 m pneumatic tubing with a pressure ball incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008420

Dimensions: Type: PT

2.4 Cancel button


To be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

1 cancel button (green) on a membrane keypad with a control LED, 1 connection panel with screw-free clips; incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC008430
FC38502E-A

Dimensions: Type: AT
103

product catalogue V1.2

VISO-OPT PLUS

Datasheets

2.5 Connection Device


to be installed in a single switchbox, consisting of a supporting frame with circuit board, on which the function and monitoring circuitry is contained as well as

1 connector for contact for push button type BT-RK 1 call button (red, marked with a nurse symbol) on a membrane keypad with 2 control LEDs, finder light included 1 connection panel with screw-free clips; incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010

Dimensions:

Caution: Connection device SVM-K can only be used in conjunction with the power supply described in point 3.1 below. If the connection device is connected to terminals which use the transformers displayed below in points 3.2 and 3.3, then the connection device will not function properly. Type: SVMSVM-K Order number: FC008320

2.6 Push button


The simple push button for the patient for rapid and easy call triggering, for connection to the connection device described in point 2.5, consisting of:

1 call button (red, marked with a nurse symbol) with 2 control LEDs, finder light included 6.3mm jack plug for connection to unit SVM-K Includes a 2.8m connection cable 90x60x20mm (HxWxD) plastic casing in colour RAL 9010

Dimensions:

Type: BTBT-RK

Order number: FC008230

104

product catalogue V1.2

FC38502E-A

VISO-OPT PLUS

Datasheets

Power supply and Transformer

As the terminals installed within the system require 24V DC current, the necessary power supply is described below.

3.1 Power supply with battery modul


For supplying power to VISO-OPT PLUS terminals as well as connected peripheral devices and signal lamps. The device conforms to EMC standards EN55022 Class B, EN61000-4-2, 3, 4, 5,6,8,11 and EN61000-3-2 and -3. Technical details: Power supply: Input current: Leakage current: Output voltage: Output continuous current: Peak current: Residual ripple: Load variation: Ambient temperature: Power supply operating temp.: Battery operating temperature: Changeover interval: Dimensions: Type: NG24NG24-2 230V/50Hz 1A 1 mA 24 V= 1.8 A 2A 100mVss +/- 0.03% per C max. 40C at 1,5A -10C to +60C -20C to +85C 60ms 220x275x110mm (WxHxD) Order number: FC008723

3.2 Transformer 50VA


Single phase transformer - sealed-in model with electrically isolated primary and secondary windings. Manufactured in compliance with VE regulation M/EN 61558, moisture proofed by impregnation. Technical details: Power supply: Primary current: Secondary current: Flat fuse: OEK regulation: Warmth class B: Isolation range 1: Connection: Dimensions: Weight: Type: TR50 230V/50Hz 0.26 A 2.08 A 3A (secondary) M/EN 61558 max. ambient temperature 40C at 75C excess temperature Testing voltage 4000V/50Hz for 1 minute sealed cable with earthed plug 66x68x115mm (WxHxD) 1.35 kg

Order number: KU923050

105

product catalogue V1.2

FC38502E-A

VISO-OPT PLUS

Datasheets

3.3 3.3

Transformer 100VA
Single phase transformer - sealed-in model (IP56) with electrically isolated primary and secondary windings. Manufactured in compliance with VE regulation M/EN 61558, moisture proofed by impregnation. Technical details: Power supply: Primary current: Glass fuse: Secondary current: OEK regulation: Warmth class B: Isolation range 1: Connection: Dimensions: Weight: Type: TR100 230V/50Hz 0.52 A 0.71A (secondary) 4.17 A M/EN 61558 max. ambient temperature 40C at 75C excess temperature Testing voltage 4000V/50Hz for 1 minute Primary and secondary side screw clips 112x146x158mm (WxHxD) 2.4 kg

Order number: KU923100

106

product catalogue V1.2

FC38502E-A

VISOCALL FUNK

VISOCALL VISOCALL FUNK

107

product catalogue V1.2

FC38502E-A

VISOCALL FUNK

Characteristic System Properties

The VISOCALL FUNK system is used in particular in old peoples homes and care homes or also in certain areas within a hospital. The system is primarily used to supplement the nurse call system, but can, however, also be combined with a phone dialling device for use privately.

1.1 Maximum Security


Complete system failure impossible Each radio transmitter is fitted with an internal capacity controller. The transmitter can display promptly, by means of the control LED, that it is time to change the battery.

1.2 Optimal Optimal concept for devices


Well thought out components are the mark of VISOCALL FUNKs devices concept: Transmitter Battery powered radio transmitter for triggering a mobile call. Receiver Radio units which can be connected to VISOCALL PLUS and all foreign systems which have voltage-free inputs. Power supplies A 24V= power supply, with a maximum power supply of 2A is available for supplying the radio receiver with power. When connected to the VISOCALL PLUS connection device, the necessary supply voltage required can of course be drawn from the power supply network for the nurse call system. Accessories When using VISOCALL FUNK in combination with VISOCALL PLUS, please see connection devices listed in chapter 1.

108

product catalogue V1.2

FC38502E-A

VISOCALL FUNK

Datasheets

Datasheets
1 Radio components
For plugging into the VISOCALL PLUS connection devices or into 6 pin DIN sockets in standard single installation cases and all other foreign systems which make a voltage-free input available for the call receiver.

1.1 Standard radio receiver


The cablefree radio receiver for connection to connection device SV-F (see 1.3), which is installed in a single installation case. It consists of:

A plastic case with membrance and cable approx. 100mm long 1 socket for DIN connector red control LED for visual signalling of a call having been triggered. green control LED for displaying operating status yellow control LED for displaying battery status

Dimensions:

95x47x31mm (HxWxD) in colour RAL 9010

Type: EE2EE2-6

Order number: FC007961

109

product catalogue V1.2

FC38502E-A

VISOCALL FUNK

Datasheets

1.2 Radio receiver for VISOCALL PLUS


The cablefree radio receiver is connected to a VISOCALL PLUS connection device, which is installed in a double installation case. It consists of:

A plastic case with membrance and cable approx. 100mm long 1 socket for a 15 pin SUB/D connector red control LED for visual signalling of a call having been triggered. green control LED for displaying operating status yellow control LED for displaying battery status 95x47x57mm (HxWxD) in colour RAL 9010

Dimensions:

Type: EE2EE2-15

Order number: FC007962

1.3 Radio Connection Device


Connection device SV-F is manufactured in the VISOCALL PLUS look and is installed in a single installation case. It is used as a connection device for radio receiver EE2-6 (1.1) and consists of:

Plastic case with membrane 1 socket for 6 pin EE2-6 incl. covering panel 80x83x13mm (HxWxD) in colour RAL 9010 Order number: FC007980

Dimensions:

Type: SVSV-F

110

product catalogue V1.2

FC38502E-A

VISOCALL FUNK

Datasheets

1.4 Wrist transmitter transmitter


The wrist transmitter is attached around the wrist and is used for mobile call triggering, and consists of:

A plastic case with integrated call button for call triggering Plastic wrist strap with fastening red control LED for visual signalling of a call having been triggered. Range: up to 20m in a clear line of sight and triggered as hip level Integrated battery monitoring Transmitter 45x40x15mm (HxWxD) in anthracite colour Wrist strap 200x25x5mm (LxWxD) in colour black

Dimensions:

Type: AS2 AS2

Order number: FC007964

1.5 Pendant transmitter


The pendant transmitter is worn around the neck and is used for mobile call triggering, and consists of:

A plastic case with integrated call button for call triggering Plastic chance with fastener red control LED for visual signalling of a call having been triggered. Range: up to 20m in a clear line of sight and triggered as hip level Integrated battery monitoring Transmitter 60x40x16mm (HxWxD) in anthracite colour Chain 800x5mm (LxDiameter) in colour grey

Dimensions:

Type: US2

Order number: FC007965

1.6 Pneumatic transmitter


The pneumatic radio call button is used for mobile triggering of calls on a table or by pressing it with the foot or chin etc., consisting of:

A plastic case with integrated call button for call triggering red control LED for visual signalling of a call having been triggered. Range: up to 15m in clear line of sight Integrated battery monitoring 100x35mm (Diameter x H), red button ca. 165g Order number: FC007966

Dimensions: Weight: Type: PS2

111

product catalogue V1.2

FC38502E-A

VISOCALL FUNK

Datasheets

SCHRACK SECONET AG

Wien-Vienna Eibesbrunnergasse 18 A 1122 Wien Tel.: +43-1-81157-0 office@schrack-seconet.com

www.schrackwww.schrack-seconet.com

112

product catalogue V1.2

FC38502E-A