Vous êtes sur la page 1sur 8

CE-N

Client:
Project:

Job No.:
Design by:
Date:

Muttha Tower, Yerwada, Pune

Page No.

hgk
26-Sep-13
G2

SPREADSHEET OF DESIGN OF RECTANGULAR COLUMN SECTION BY LIMIT STATE METHOD

FOR AXIAL COMPRESSIVE LOAD & UNIAXIAL BENDING MOMENT AS PER IS:456-2000
Calculates range of safe loads for a section of short Column (Cl. 25.1.2 of IS:456-2000), with given Concrete Grade
and Reinforcement, and checks adequacy of the section for the given loads.
Column Dimensions:
Breadth, 'b' =
Depth, 'D' =
Concrete Grade =

Yield Strength of Steel, fy =


Concrete Cover to main bars =

300 mm
1000 mm
5
2
N/mm
40 mm

Details of Reinforcement:
Row1-6 Nos. of bars Bar Dia (mm)

1
2
3
4
5
6

4
2
2
2
4

16
16
16

16
16
Total Ast =
Percentage of Reinforcement =

Ast (mm )

d1-6 (mm)

Y1-6 from CL(mm)

804
402
402
0
402
804
2814
0.938

48.00
198.00
500.00

452.00
302.00
0.00
0.00
-302.00
-452.00

802.00
952.00
< 4% O.K.

Design
Col. Applied Ultimate Loads Unsupported Moment due to
Permissible Max. Tensile
Mk.
Pu (kN) Mux (kNm) Col. Length(m)Min. Ecc.(kNm) Mux (kNm) Mux (kNm) Stress (N/mm2)
B814-LC9 1910.29
-145.37
3.750
38.21
38.21
886.25
354.51
B814-LC201761.27
-219.48
3.750
35.23
35.23
878.03
358.34
B814-LC211471.32
-34.16
3.750
29.43
29.43
848.63
360.90
B814-LC221688.91
-122.95
3.750
33.78
33.78
872.30
359.88
B814-LC231543.67
-122.74
3.750
30.87
30.87
857.56
360.90
B814-LC281114.75
-176.03
3.750
22.30
22.30
793.40
360.90
B814-LC29 824.80
45.67
3.750
16.50
45.67
725.45
360.90
B814-LC31 897.16
-79.29
3.750
17.94
17.94
743.97
360.90
3.750
0.00
0.00
3.750
0.00
0.00
-

Status
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
-

CE-N
Client:
Project:

Job No.:
Design by:
Date:

Muttha Tower, Yerwada, Pune

Page No.

hgk
26-Sep-13
G2

DESIGN OF RECTANGULAR COLUMN SECTION BY LIMIT STATE METHOD


FOR AXIAL COMPRESSIVE LOAD & UNIAXIAL BENDING MOMENT AS PER IS:456-2000

SPREADSHEET OF

Calculates range of safe loads for a section of short Column (Cl. 25.1.2 of IS:456-2000), with given Concrete Grade
and Reinforcement, and checks adequacy of the section for the given loads.
Column Dimensions:
Breadth, 'b' =
Depth, 'D' =
Concrete Grade =

300 mm
1000 mm
5

Yield Strength of Steel, fy =


Concrete Cover to main bars =

N/mm2
40 mm

Details of Reinforcement:
Row1-6 Nos. of bars Bar Dia (mm)

1
2
3
4
5
6

4
2
2
2
4

16
16
16

16
16
Total Ast =
Percentage of Reinforcement =

Ast (mm2)

d1-6 (mm)

Y1-6 from CL(mm)

804
402
402
0
402
804
2814
0.938

48.00
198.00
500.00

452.00
302.00
0.00
0.00
-302.00
-452.00

802.00
952.00
< 4% O.K.

Col. Applied Ultimate Loads Unsupported Moment due to


Design
Permissible Max. Tensile
Col.
Length(m)
Min.
Ecc.(kNm)
Mk.
Pu (kN) Mux (kNm)
Mux (kNm) Mux (kNm) Stress (N/mm2)
B96-LC9 3916.73
93.79
3.750
78.33
93.79
603.26
43.05
B96-LC2 3255.22
-111.02
3.750
65.10
65.10
756.11
170.06
B96-LC2 2904.07
237.39
3.750
58.08
237.39
819.85
249.44
B96-LC2 3229.57
-251.44
3.750
64.59
64.59
761.09
175.56
B96-LC2 2929.72
200.02
3.750
58.59
200.02
815.44
243.40
B96-LC2 2023.36
-136.29
3.750
40.47
40.47
890.04
350.87
B96-LC2 1672.21
212.11
3.750
33.44
212.11
870.97
360.24
B96-LC3 1697.86
210.30
3.750
33.96
210.30
873.02
359.69
3.750
0.00
0.00
3.750
0.00
0.00
-

Status
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
-

CE-N
Client:
Project:

Job No.:
Design by:
Date:

Muttha Tower, Yerwada, Pune

Page No.

hgk
26-Sep-13
G27

SPREADSHEET OF DESIGN OF RECTANGULAR COLUMN SECTION BY LIMIT STATE METHOD

FOR AXIAL COMPRESSIVE LOAD & UNIAXIAL BENDING MOMENT AS PER IS:456-2000
Calculates range of safe loads for a section of short Column (Cl. 25.1.2 of IS:456-2000), with given Concrete Grade
and Reinforcement, and checks adequacy of the section for the given loads.
Column Dimensions:
Breadth, 'b' =
Depth, 'D' =
Concrete Grade =

Yield Strength of Steel, fy =


Concrete Cover to main bars =

450 mm
1000 mm
5
2
N/mm
40 mm

Details of Reinforcement:
Row1-6 Nos. of bars Bar Dia (mm)

1
2
3
4
5
6

4
2
2
2
4

16
16
16

16
16
Total Ast =
Percentage of Reinforcement =

Ast (mm )

d1-6 (mm)

Y1-6 from CL(mm)

804
402
402
0
402
804
2814
0.625

48.00
198.00
500.00

452.00
302.00
0.00
0.00
-302.00
-452.00

802.00
952.00
< 4% O.K.

Design
Col. Applied Ultimate Loads Unsupported Moment due to
Permissible Max. Tensile
Mk.
Pu (kN) Mux (kNm) Col. Length(m)Min. Ecc.(kNm) Mux (kNm) Mux (kNm) Stress (N/mm2)
B808-LC9 2648.36
-192.71
3.750
59.59
59.59
1149.19
358.57
B808-LC202417.74
-308.06
3.750
54.40
54.40
1126.23
360.90
B808-LC211993.63
-63.24
3.750
44.86
44.86
1067.24
360.90
B808-LC222340.77
-305.58
3.750
52.67
52.67
1117.07
360.90
B808-LC232070.61
-155.86
3.750
46.59
46.59
1078.99
360.90
B808-LC281535.47
-249.93
3.750
34.55
34.55
974.35
360.90
B808-LC291111.36
75.54
3.750
25.01
75.54
859.84
360.90
B808-LC311188.33
175.40
3.750
26.74
175.40
882.55
360.90
3.750
0.00
0.00
3.750
0.00
0.00
-

Status
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
-

CE-N
Client:
Project:

Job No.:
Design by:
Date:

Muttha Tower, Yerwada, Pune

Page No.

hgk
26-Sep-13
G27

SPREADSHEET OF DESIGN OF RECTANGULAR COLUMN SECTION BY LIMIT STATE METHOD

FOR AXIAL COMPRESSIVE LOAD & UNIAXIAL BENDING MOMENT AS PER IS:456-2000
Calculates range of safe loads for a section of short Column (Cl. 25.1.2 of IS:456-2000), with given Concrete Grade
and Reinforcement, and checks adequacy of the section for the given loads.
Column Dimensions:
Breadth, 'b' =
Depth, 'D' =
Concrete Grade =

Yield Strength of Steel, fy =


Concrete Cover to main bars =

450 mm
1000 mm
5
2
N/mm
40 mm

Details of Reinforcement:
Row1-6 Nos. of bars Bar Dia (mm)

1
2
3
4
5
6

4
2
2
2
4

16
16
16

16
16
Total Ast =
Percentage of Reinforcement =

Ast (mm )

d1-6 (mm)

Y1-6 from CL(mm)

804
402
402
0
402
804
2814
0.625

48.00
198.00
500.00

452.00
302.00
0.00
0.00
-302.00
-452.00

802.00
952.00
< 4% O.K.

Design
Col. Applied Ultimate Loads Unsupported Moment due to
Permissible Max. Tensile
Mk.
Pu (kN) Mux (kNm) Col. Length(m)Min. Ecc.(kNm) Mux (kNm) Mux (kNm) Stress (N/mm2)
B89-LC9 4770.90
84.80
3.750
107.35
107.35
1008.00
160.12
B89-LC20 3943.37
-143.96
3.750
88.73
88.73
1134.10
296.59
B89-LC21 3496.03
257.51
3.750
78.66
257.51
1166.03
329.78
B89-LC22 3912.32
-253.02
3.750
88.03
88.03
1137.18
299.79
B89-LC23 3527.08
202.11
3.750
79.36
202.11
1164.38
327.95
B89-LC28 2455.49
-166.67
3.750
55.25
55.25
1130.73
360.90
B89-LC29 2008.15
234.80
3.750
45.18
234.80
1069.45
360.90
B89-LC31 2039.20
212.29
3.750
45.88
212.29
1074.19
360.90
3.750
0.00
0.00
3.750
0.00
0.00
-

Status
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
-

CE-N
Client:
Project:

Job No.:
Design by:
Date:

Muttha Tower, Yerwada, Pune

Page No.

hgk
26-Sep-13
G49

SPREADSHEET OF DESIGN OF RECTANGULAR COLUMN SECTION BY LIMIT STATE METHOD

FOR AXIAL COMPRESSIVE LOAD & UNIAXIAL BENDING MOMENT AS PER IS:456-2000
Calculates range of safe loads for a section of short Column (Cl. 25.1.2 of IS:456-2000), with given Concrete Grade
and Reinforcement, and checks adequacy of the section for the given loads.
Column Dimensions:
Breadth, 'b' =
Depth, 'D' =
Concrete Grade =

Yield Strength of Steel, fy =


Concrete Cover to main bars =

750 mm
750 mm
5
2
N/mm
40 mm

Details of Reinforcement:
Row1-6 Nos. of bars Bar Dia (mm)

1
2
3
4
5
6

4
4

4
4

25
25

25
25
Total Ast =
Percentage of Reinforcement =

Ast (mm )

d1-6 (mm)

Y1-6 from CL(mm)

1963
1963
0
0
1963
1963
7852
1.396

52.50
202.50

322.50
172.50
0.00
0.00
-172.50
-322.50

547.50
697.50
< 4% O.K.

Design
Col. Applied Ultimate Loads Unsupported Moment due to
Permissible Max. Tensile
Mk.
Pu (kN) Mux (kNm) Col. Length(m)Min. Ecc.(kNm) Mux (kNm) Mux (kNm) Stress (N/mm2)
B146-LC9 8704.50
-450.40
3.750
282.90
282.90
725.37
37.65
B146-LC206724.10
-347.10
3.750
218.53
218.53
1115.62
128.82
B146-LC216591.70
-338.10
3.750
214.23
214.23
1136.74
141.79
B146-LC226454.00
-395.80
3.750
209.76
209.76
1157.70
155.83
B146-LC236861.70
-289.40
3.750
223.01
223.01
1093.55
115.40
B146-LC284060.90
-210.10
3.750
131.98
131.98
1405.40
342.33
B146-LC293928.50
213.40
3.750
127.68
213.40
1410.52
345.81
B146-LC314198.50
-152.40
3.750
136.45
136.45
1398.79
337.81
3.750
0.00
0.00
3.750
0.00
0.00
-

Status
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
-

CE-N
Client:
Project:

Job No.:
Design by:
Date:

Muttha Tower, Yerwada, Pune

Page No.

hgk
26-Sep-13
G51

SPREADSHEET OF DESIGN OF RECTANGULAR COLUMN SECTION BY LIMIT STATE METHOD

FOR AXIAL COMPRESSIVE LOAD & UNIAXIAL BENDING MOMENT AS PER IS:456-2000
Calculates range of safe loads for a section of short Column (Cl. 25.1.2 of IS:456-2000), with given Concrete Grade
and Reinforcement, and checks adequacy of the section for the given loads.
Column Dimensions:
Breadth, 'b' =
Depth, 'D' =
Concrete Grade =

Yield Strength of Steel, fy =


Concrete Cover to main bars =

750 mm
750 mm
5
2
N/mm
40 mm

Details of Reinforcement:
Row1-6 Nos. of bars Bar Dia (mm)

1
2
3
4
5
6

4
4
2
2
4
4

25
25
25
25
25
25
Total Ast =
Percentage of Reinforcement =

Ast (mm )

d1-6 (mm)

Y1-6 from CL(mm)

1963
1963
982
982
1963
1963
9816
1.745

52.50
202.50
337.50
412.50
547.50
697.50

322.50
172.50
37.50
-37.50
-172.50
-322.50

< 4% O.K.

Design
Col. Applied Ultimate Loads Unsupported Moment due to
Permissible Max. Tensile
Mk.
Pu (kN) Mux (kNm) Col. Length(m)Min. Ecc.(kNm) Mux (kNm) Mux (kNm) Stress (N/mm2)
B147-LC9 9607.80
61.90
3.750
312.25
312.25
644.71
6.36
B147-LC207246.60
-65.80
3.750
235.51
235.51
1110.24
123.76
B147-LC217184.70
97.20
3.750
233.50
233.50
1119.53
129.36
B147-LC227252.40
-42.20
3.750
235.70
235.70
1109.37
123.23
B147-LC237178.90
135.90
3.750
233.31
233.31
1120.40
129.88
B147-LC284360.30
-72.10
3.750
141.71
141.71
1401.93
337.14
B147-LC294298.50
90.90
3.750
139.70
139.70
1404.47
338.87
B147-LC314292.70
117.20
3.750
139.51
139.51
1404.71
339.03
3.750
0.00
0.00
3.750
0.00
0.00
-

Status
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
-

CE-N
Client:
Project:

Job No.:
Design by:
Date:

Muttha Tower, Yerwada, Pune

Page No.

hgk
26-Sep-13
G53

SPREADSHEET OF DESIGN OF RECTANGULAR COLUMN SECTION BY LIMIT STATE METHOD

FOR AXIAL COMPRESSIVE LOAD & UNIAXIAL BENDING MOMENT AS PER IS:456-2000
Calculates range of safe loads for a section of short Column (Cl. 25.1.2 of IS:456-2000), with given Concrete Grade
and Reinforcement, and checks adequacy of the section for the given loads.
Column Dimensions:
Breadth, 'b' =
Depth, 'D' =
Concrete Grade =

Yield Strength of Steel, fy =


Concrete Cover to main bars =

900 mm
900 mm
5
2
N/mm
40 mm

Details of Reinforcement:
Row1-6 Nos. of bars Bar Dia (mm)

1
2
3
4
5
6

4
4

4
4

25
25

25
25
Total Ast =
Percentage of Reinforcement =

Ast (mm )

d1-6 (mm)

Y1-6 from CL(mm)

1963
1963
0
0
1963
1963
7852
0.969

52.50
202.50

397.50
247.50
0.00
0.00
-247.50
-397.50

697.50
847.50
< 4% O.K.

Design
Col. Applied Ultimate Loads Unsupported Moment due to
Permissible Max. Tensile
Mk.
Pu (kN) Mux (kNm) Col. Length(m)Min. Ecc.(kNm) Mux (kNm) Mux (kNm) Stress (N/mm2)
B140-LC910498.60
-94.80
3.750
393.70
393.70
1486.05
41.93
B140-LC208043.60
-113.90
3.750
301.64
301.64
1965.29
225.39
B140-LC217906.90
105.00
3.750
296.51
296.51
1986.80
237.25
B140-LC227736.80
-232.20
3.750
290.13
290.13
2012.55
252.48
B140-LC238213.70
89.70
3.750
308.01
308.01
1938.54
210.64
B140-LC284853.50
-112.10
3.750
182.01
182.01
2182.88
356.80
B140-LC294716.80
106.80
3.750
176.88
176.88
2174.20
358.24
B140-LC315023.60
118.20
3.750
188.39
188.39
2192.69
355.04
3.750
0.00
0.00
3.750
0.00
0.00
-

Status
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
-

CE-N
Client:
Project:

Job No.:
Design by:
Date:

Muttha Tower, Yerwada, Pune

Page No.

hgk
26-Sep-13
G54

SPREADSHEET OF DESIGN OF RECTANGULAR COLUMN SECTION BY LIMIT STATE METHOD

FOR AXIAL COMPRESSIVE LOAD & UNIAXIAL BENDING MOMENT AS PER IS:456-2000
Calculates range of safe loads for a section of short Column (Cl. 25.1.2 of IS:456-2000), with given Concrete Grade
and Reinforcement, and checks adequacy of the section for the given loads.
Column Dimensions:
Breadth, 'b' =
Depth, 'D' =
Concrete Grade =

Yield Strength of Steel, fy =


Concrete Cover to main bars =

900 mm
900 mm
5
2
N/mm
40 mm

Details of Reinforcement:
Row1-6 Nos. of bars Bar Dia (mm)

1
2
3
4
5
6

4
4
2
2
4
4

25
25
25
25
25
25
Total Ast =
Percentage of Reinforcement =

Ast (mm )

d1-6 (mm)

Y1-6 from CL(mm)

1963
1963
982
982
1963
1963
9816
1.212

52.50
202.50
412.50
487.50
697.50
847.50

397.50
247.50
37.50
-37.50
-247.50
-397.50

< 4% O.K.

Design
Col. Applied Ultimate Loads Unsupported Moment due to
Permissible Max. Tensile
Mk.
Pu (kN) Mux (kNm) Col. Length(m)Min. Ecc.(kNm) Mux (kNm) Mux (kNm) Stress (N/mm2)
B141-LC910913.90
67.70
3.750
409.27
409.27
1516.99
49.78
B141-LC208187.10
-71.30
3.750
307.02
307.02
2002.67
244.59
B141-LC218118.80
69.70
3.750
304.46
304.46
2011.96
250.27
B141-LC228195.90
-112.40
3.750
307.35
307.35
2001.48
243.85
B141-LC238110.00
214.40
3.750
304.13
304.13
2013.15
251.00
B141-LC284925.90
-71.00
3.750
184.72
184.72
2193.04
355.69
B141-LC294857.60
70.00
3.750
182.16
182.16
2189.92
356.26
B141-LC314848.80
194.00
3.750
181.83
194.00
2189.52
356.33
3.750
0.00
0.00
3.750
0.00
0.00
-

Status
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
Section O.K.
-

Vous aimerez peut-être aussi