PROFIS Anchor 2.

1
OVERVIEW

SEISMIC PROVISIONS

ANCHOR REINFORCEMENT

REDUCED EDGE DISTANCE

DESIGN REPORT

CANADA
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

TENSION 0.75 factor for Seismic Design Categories C-F is not applied to Steel Strength 0.75 factor is applied to these tension design strengths: Concrete Breakout Strength 0.75concreteNcb or 0.75concreteNcbg Pullout Strength - 0.75concreteNpn or 0.75concreteNpn,fc Side-Face Blowout Strength - 0.75concreteNsb or 0.75concreteNsbg Bond Strength - 0.75bondNa or 0.75bondNag PA2.1 designates the 0.75 factor as seismic.
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

SHEAR 0.75 factor for Seismic Design Categories C-F is not applied to Steel Strength 0.75 factor is applied to these shear design strengths: Concrete Breakout Strength - 0.75concreteVcb or 0.75concreteVcbg Pryout Strength - 0.75concreteVcp or 0.75concreteVcpg PA2.1 designates the 0.75 factor as seismic.

www.hilti.com

R.T. Morgan | PA2.1 Seismic Provisions

| October 2010

PROFIS Anchor 2.1

Click on the Loads tab. Click on the icon Seismic Design to open seismic design options. Click on the dot next to D.3.3.4 to select seismic design per D.3.3.4

www.hilti.com

R.T. Morgan | PA2.1 Seismic Provisions

| October 2010

PROFIS Anchor 2.1

PA2.1 will calculate steelNsa and seismic(concrete or bond)NN for tension loads. If steelNsa < seismic (concrete or bond)NN and the anchor is a ductile steel element D.3.3.4 is satisfied. Design Report will indicate Fastening meets the design criteria !

www.hilti.com

R.T. Morgan | PA2.1 Seismic Provisions

| October 2010

PROFIS Anchor 2.1

PA2.1 will calculate steelNsa and seismic (concrete or bond)NN for tension loads. If steelNsa > seismic (concrete or bond)NN and the anchor is a ductile steel element D.3.3.4 is NOT satisfied. If the anchor is a nonductile steel element D.3.3.4 is NOT satisfied. Design Report will indicate Fastening does not meet the design criteria !
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

PA2.1 will calculate steelVsa and seismic concreteVN for shear loads. If steelVsa < seismic concreteVN and the anchor is a ductile steel element D.3.3.4 is satisfied. Design Report will indicate Fastening meets the design criteria !

www.hilti.com

R.T. Morgan | PA2.1 Seismic Provisions

| October 2010

PROFIS Anchor 2.1

PA2.1 will calculate steelVsa and seismic concrete VN for shear loads. If steelVsa > seismic concreteVN and the anchor is a ductile steel element D.3.3.4 is NOT satisfied. If the anchor is a nonductile steel element D.3.3.4 is NOT satisfied. Design Report will indicate Fastening does not meet the design criteria !
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

The PA2.1 Design Report may indicate Fastening does not meet the design criteria ! if D.3.3.4 has been selected as a design option. The ductility requirements of D.3.3.4 do not have to be met if designing nonstructural components per IBC 2009.
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

Click on the Loads tab. Click on the icon Seismic Design to open seismic design options. Click on the dot next to D.3.3.5 to select seismic design per D.3.3.5

www.hilti.com

R.T. Morgan | PA2.1 Seismic Provisions

| October 2010

PROFIS Anchor 2.1

When D.3.3.5 is selected, this message will appear.

Click Yes to re-input loads corresponding to yielding of the attachment. The Enter loads option will open.

Click No to keep original loads.


www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

PA2.1 designates the reduction factor for nonductile failure modes: nonductile nonductile defaults to 1.0 in the PA2.1 calculations when D.3.3.5 is selected. PA2.1 will calculate seismic(concrete or bond)nonductile NN for tension loads using nonductile = 1.0. PA2.1 will calculate seismicconcrete nonductile VN for shear loads using

nonductile = 1.0.
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

Users can input values for nonductile = 1.0 via the D.3.3.6 option when designing nonstructural components per IBC 2009. PA2.1 will calculate seismic(concrete or bond)nonductile NN for tension loads using nonductile = 1.0. PA2.1 will calculate seismicconcrete nonductile VN for shear loads using

nonductile = 1.0.
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

The PA2.1 Design Report will alert users to inputting values for nonductile equal to 1.0 corresponding to yielding of the connection.

www.hilti.com

R.T. Morgan | PA2.1 Seismic Provisions

| October 2010

PROFIS Anchor 2.1

PA2.1 designates the reduction factor for nonductile failure modes: nonductile nonductile defaults to 0.4 in PA2.1. Users can input values for nonductile ranging from 0.4 to 1.0. PA2.1 will calculate seismic(concrete or bond)nonductile NN for tension loads using the value input for nonductile when D.3.3.6 is selected. PA2.1 will calculate seismicconcrete nonductile VN for shear loads using the value input for nonductile when D.3.3.6 is selected.
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

nonductile is applied to steelNsa and steelVsa if the anchor steel is a nonductile


element. nonductile is not applied to steel(Nsa or Vsa) for cast-in-place anchors ductile steel elements nonductile is not applied to steel(Nsa or Vsa) for B7 threaded rods ductile steel elements PA2.1 will calculate steel nonductile (Nsa or Vsa) for HAS 5.8 threaded rods nonductile elements. PA2.1 will calculate steel nonductile (Nsa or Vsa) for stainless steel rods nonductile elements.
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

nonductile is applied to steelNsa and steelVsa if the anchor steel is a nonductile


element. nonductile is not applied to steel(Nsa or Vsa) for HDA Anchors ductile steel elements nonductile is not applied to steel(Nsa or Vsa) for HSL-3 anchors ductile steel elements nonductile is not applied to steel(Nsa or Vsa) for Kwik Bolt-TZ anchors ductile steel elements

www.hilti.com

R.T. Morgan | PA2.1 Seismic Provisions

| October 2010

PROFIS Anchor 2.1

Click on the Loads tab. Click on the icon Seismic Design to open seismic design options. Click on the dot next to D.3.3.6 to select seismic design per D.3.3.6 Input a value for nonductile ranging between 0.4 and 1.0

www.hilti.com

R.T. Morgan | PA2.1 Seismic Provisions

| October 2010

PROFIS Anchor 2.1

PA2.1 will calculate seismic(concrete or bond)nonductile NN for tension loads using the value input for nonductile when D.3.3.6 is selected. PA2.1 will calculate seismicconcrete nonductile VN for shear loads using the value input for nonductile when D.3.3.6 is selected.
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

The PA2.1 Design Report will alert users to inputting values for nonductile different from the ACI 318-08 default value of 0.4.

www.hilti.com

R.T. Morgan | PA2.1 Seismic Provisions

| October 2010

PROFIS Anchor 2.1

can be selected with

Permits users to select uncracked concrete via the Base Material tab for seismic conditions. PA2.1 will perform calculations using uncracked concrete parameters: kuncr , k,uncr , k,max,uncr , c,N , c,v , etc. PA2.1 will still apply any seismic-specific factors to calculated values: N seis , seismic , etc.
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010

PROFIS Anchor 2.1

can be selected with

All cast-in-place anchors in the PA2.1 anchor portfolio. Hilti anchors that have been qualified for seismic/cracked concrete. HY 150 MAX-SD and RE 500-SD HDA, HSL-3 and KWIK Bolt-TZ NOT APPLICABLE to Hilti anchors NOT qualified for seismic/cracked concrete. HY 150 MAX KWIK Bolt 3
www.hilti.com R.T. Morgan | PA2.1 Seismic Provisions | October 2010