Académique Documents
Professionnel Documents
Culture Documents
: 1998-514-0002
....................................................................................................................
Statistical data on the performance of fossil-fuelled power plants General report (1990-1997)
....................................................................................................................
Accessibility : Public
As of 1st January 1998, UNIPEDE and EURELECTRIC have formed a Joint Secretariat situated in Brussels. UNIPEDE and EURELECTRIC are organisations with a separate identity, co-operating closely to provide effective and coherent assistance to their Members, in order to ensure and develop the Industry's competitiveness and in order to offer and develop competitive and environmentally sound products, in the interest of its customers. In doing so, UNIPEDE and EURELECTRIC will pay due respect to the specific missions and responsibilities of other international organisations of the European Electricity Supply Industry. UNIPEDE is the association of the European Electricity Industry and of world wide affiliates and associates that operates as a centre of strategic expertise and that acts as a liaison with other international associations and organisations with the aim to identify and respect the common interests of its Members and to assist the Members in deciding on the solutions to be implemented and in co-ordinating and carrying out the necessary action. EURELECTRIC is the association of the European Union Electricity Industry representing it in public affairs, in particular in relation to the EU institutions, in order to promote its interests at the political level. The reports published by UNIPEDE/EURELECTRIC are the result of the work of its structure of expertise: they represent one of the most direct methods of circulating knowledge and information throughout the sector, on subjects of common interest. They are intended for wide circulation both within the electricity supply industry and outside it. Please do not hesitate to ask for the latest available printed UNIPEDE/EURELECTRIC publications catalogue (with summaries of UNIPEDE/EURELECTRIC reports) from:
UNIPEDE/EURELECTRIC Documentation 66 Boulevard de l'Impratrice BE-1000 Brussels BELGIUM Tel: +32 2 515 10 00 Fax: +32 2 515 10 10
You can also use the UNIPEDE/EURELECTRIC Internet Web site, which provides the following information: UNIPEDE/ EURELECTRIC general information Publications Catalogue Events & Conferences UNIPEDE/ EURELECTRIC Statements Statistics
http://unipede.eurelectric.org
You can also contact the UNIPEDE/EURELECTRIC Documentation Service at its Internet Email address for individual requests (information on UNIPEDE/ EURELECTRIC reports, transmission of your order forms etc.):
documentation@unipede.org
Statistical data on the performance of fossil-fuelled power stations General report (1990-1997)
........................................................................................................................................................................................................
Coordinator: Daniel GLORIAN (EDF, France) Members: Johann PRECHT (sterreichische Draukraftwerke AG, Austria); JeanLouis LAMS (ELECTRABEL, Belgium) ; Pierre DESPONDS (EOS, Switzerland); Jaromir HAJNY (CEZ a.s., Czech Republic); O. NITSCH (VGB, Germany); Jorgen OLSEN (ELKRAFT, Denmark); Antonio LOPEZ DE SEBASTIAN (UNESA, Spain); Michel BRUAUX (EDF, France); gota KBOR (MVM Rt., Hungary); Shane STANLY (ESB, Ireland); Arie PEER (Israel Electric Corp., Israel); Vittorio DE MARIA (ENEL, Italy); Johannes G. A. BUSSER (N.V Sep, Netherlands); Luis DA SILVA CARRILHO (CPPE S.A., Portugal); Bhongo MDUNGE (ESKOM, South Africa). Editors: Daniel GLORIAN Patrick BLIN
Copyright UNIPEDE/EURELECTRIC, 1998 All rights reserved Printed at UNIPEDE/EURELECTRIC, Brussels (Belgium)
CONTENTS
Page SUMMARY ................................ ................................ .......................... 1. 2. INTRODUCTION ................................ ................................ ................. BRIEF DESCRIPTION OF THE FIVE PERFORMANCE INDICATORS MONITORED ................................ ............................... BRIEF DESCRIPTION OF THE INSTALLATION FAMILIES MONITORED ................................ ................................ ...................... LIST OF GRAPHS, RESULTS IN GRAPH FORM .............................. GRAPHS ................................ ................................ ............................. i 1
3.
4 5 7 to 28
4. 5.
Appendix 1.- Statistical Terminology Employed in the Electricity Supply Industry (UNIPEDE Ref.: 91fr80/s.1) Appendix 2.- Fossil Fuel and Nuclear Power Plants Performance Indicators (UNIPEDE Ref.: 02011Ren91 - Addenda) Appendix 3.- Detailed Descriptions of International Performance Indicators for Fossil-Fired Power Pant (UNIPEDE Ref.: 02011Ren91) Appendix 4.- Data Form Appendix 5.- ASPIC (V1.1)- User s Manual (UNIPEDE Ref.: 02011Ren9541) Appendix 6.- Availability and Unavailability Factors of Thermal Generating Plants - Definitions and methods of calculation Joint UNIPEDE/WEC Committee on the Performance of Thermal Generating Plant: (UNIPEDE Ref.: 02011Ren91WEC1) Appendix 7.- UNIPEDE Performance Indicator Program - Implementation Guidelines (Fossil-fuel plants) (03/05/93 - 5 pages) Appendix 8.- Thermal generating plant (100 MW+) availability and unavailability factors" (data 1991-1993) - Triennal Report - Joint UNIPEDE/WEC Committee on the Availability of Thermal Generating Plant Sample Groups (UNIPEDE Ref.: 02011Ren9510WEC1) 1995 - 80 p. The documents, for which the first page only is in the appendices, can be obtained from the UNIPEDE Documentation.
SUMMARY
Based on UNIPEDE definitions [Appendix 2] and terminology [Appendix 1], the Statistical Experts Group: Thermal Performance has organized the collection of data covering the following five Technical Performance Indicators for Conventional Fossil-Fuel Plant: o o o o o Unit capability factor Unplanned capability loss factor Unplanned automatic grid separations per 7 000 hours of operation Successful start-up rate Industrial safety accident rate
The corresponding database is currently held within the Industry Observatory of UNIPEDE. This is the general report, covering the years 1990 to 1997. A second report, with more detailed analysis and therefore distributed only to participating countries, is edited seperatly. With regard to the future, UNIPEDE proposes extending participation to all its member countries and publishing an annual report. This program should permit valuable international comparisons and make it possible to exchange experience so as to monitor and to improve the overall performance of power plants. This report contains graphs which show the statistical results submitted for the five performance indicators. These results are supplied as a set of statistics, remaining completely anonymous, for all of the countries which agreed to participate in the launching of the UNIPEDE database.
1.
INTRODUCTION
Pursuing the program undertaken by WANO (World Association of Nuclear Operators) for nuclear power plant performance monitoring, UNIPEDE has developed a program for collecting, processing and publishing statistics relating to the performance of conventional fossil-fuelled power plants. The following five performance indicators have thus been defined, for international application, for the different areas in which operators must ensure a high degree of vigilance in order to achieve a satisfactory quality of service: - Unit capability factor - Unplanned capability loss factor - Unplanned automatic grid separations per 7 000 hours of operation. - Successful startup rate - Industrial safety accident rate Using precise terminology and definitions (Appendices 1, 2 and 3), the program has been launched by the THERPERF group of correspondents. This general report covers the years 1990 to 1997. A more comprehensive report, intended only for those countries which contribute statistics, is also drawn up. Each year, both reports are compiled and distributed by the UNIPEDE/EURELECTRIC secretariat. The corresponding information (description in Appendix 4) is submitted to UNIPEDE on diskettes using the data collection software, known as ASPIC A ( Software for Performance Indicators data Collection - Appendix 5, ASPIC User's Manual). A consolidation program, known as Picador P (erformance Indicators data Consolidation and Data Optimum Reporting), is used to integrate the different results, thus enabling the definition of installation families (type, geographic location, fuel used, power rating, year of construction, etc.), and to generate the corresponding graphs, in particular in the form of histograms. Depending on the case, the results can be any of the following: - Median values (which divides the sample into two equal groups) and the best quartile (the quarter of the sample, in number of events, which shows the "best" results). - Average (mean) values (the simple arithmetic mean) for unit capability and capability loss. - Values weighted by the power rating(or by associated weighting elements), to complete the overall picture (in particular, capability and capability loss).
The volume of samples, for each group shown, is always given in unit-years. In order to present a significant sample, a minimum of 50 unit-years is required for the graph to be printed. This program was developped to be consistent with both the program implemented by WANO for nuclear power plants and with similar work carried out within the Joint UNIPEDE/WEC Committee on the performance of thermal plants (fossil-fuel and nuclear). Integration within the UNIPEDE system makes it possible to contribute to the activities of the UNIPEDE/WEC Committee without requiring the collection of additional data (see Appendix 6). Any comments regarding this general report will be most welcome. Please write to:
Mr. Daniel GLORIAN Chef de l Observatoire Statistique du Systme Electrique. Electricit de France Cap Ampre 1, place Pleyel FR - 93282 SAINT-DENIS CEDEX FRANCE Int.Tel. = +33 1 43 69 43 13 Int.fax = +33 1 43 69 21 44
It is hoped that as many operators as possible will participate in this program. The aim of the program is to create a high-quality management tool. These indicators are intended principally for use by operators to monitor their own performance and progress, to set their own challenging goals for improvement, and to gain an additional perspective on performance relative to that of other plants. Thus, the international exchanges which will be facilitated by UNIPEDE will help foster a commitment to emulate the best practices, thereby maintaining the satisfactory level of performance observed. This report contains data submitted by representatives of the following countries:
AT BE CH CZ DE DK ES - Austria - Belgium - Switzerland - Czech Republic - Germany - Denmark - Spain FR - France HU - Hungary IE - Ireland IL - Israel IT - Italy NL - Netherlands PT - Portugal ZA - South Africa
The results given in this document correspond to all the results submitted by these countries. The country symbols shown at the top of each graph indicate the geographic field; if a country is not included, this indicates that the corresponding data was not submitted or was unable to be used according to current regulations.
2.
BRIEF DESCRIPTION OF THE FIVE PERFORMANCE INDICATORS MONITORED (Detailed description: Appendix 3)
Unit Capability Factor
Unit capability factor is the percentage of maximum energy generation that a plant is capable of supplying to the electrical grid, limited only by factors within control of plant management. A high unit capability factor indicates effective plant programs and practices to minimise unplanned energy losses and to optimise planned outages, maximising available electrical generation.
(I)
3.
The five performance indicators are monitored on a unit-by-unit basis, starting from the first full year of commercial service. Data is submitted anonymously using a unit "code", which is known only by the operator who supplies the data. To ensure complete confidentiality (no data can be used for commercial purposes), certain procedures have been defined for the exchange of this information (Appendix 7). Three categories of conventional thermal installations are monitored: A - Steam turbines B - Combined cycle, cogeneration C - Combustion turbines. Four types of fuel are monitored: 1 - Coal (excluding lignite and others) 2 - Lignite and others 3 - Liquid fuels 4 - Gaseous fuels. The power rating categories are those recommended by the Joint UNIPEDE/WEC Committee. These power ratings are shown for each installation category in Appendix 8. For the years 1990 to 1997, a total of a) of which 4515 3996 280 239 4275 2675 1585 996 unit-years of data have been provided by participating countries for at least one indicator, for steam turbines, for combined cycles & cogeneration plants, for combustion turbines, provided UCF and UCLF, provided UAGS7 provided ISAR provided SSR.
b)
and of which
4.
- Coal (excl. Lign. & others), all sizes, all countries (distribution) . p. 16 - Coal (excl. Lign. & others), all sizes, median (by year) .............. p. 17 - Coal (excl. Lign. & others), all sizes, median (by country) .......... p. 18 - Lignite & others, all sizes, all countries (distribution) ................. - Lignite & others, all sizes, median (by year) ............................... - Liquid, all sizes, all countries (distribution) ................................. - Liquid, all sizes, median (by year 1990-1995) ............................ - Gaseous, all sizes, all countries (distribution) ............................ p. 19 p. 20 p. 21 p. 22 p. 23
l Unplanned automatic grid separations per 7 000 operating hours * Steam turbines
- All fuels, all sizes, all countries (distribution) .............................. - All fuels, all sizes, median (by year) ........................................... - All fuels, all sizes, median (by country) ...................................... - All fuels, all sizes, median by age (distribution) .......................... p. p. p. p. 25 25 26 26
* Steam turbines
- All fuels, all sizes, all countries (distribution) .............................. p. 28
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Distribution
Median 86.87 700 654 Best Quartile 92.82 656
600
541
500 number of units 422 400 3242 Unit.Years Arith. Mean=82.54 296 300 173 134 103 100 12 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 6 5 11 5 10 15 23 23 42 56 55
200
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Distribution
Best Quartile 1.67 Median 3.67 1985 2000
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Median Values
100
95 89.6
88.8
80
75
70 1990 412 1991 441 1992 438 1993 400 1994 379 1995 388 1996 411 1997 373
Year/Unit.Years
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Median Values
10 9 8 7 percent 6 5 4 3 2 1 0 1990 412 1991 441 1992 438 1993 400 1994 379 1995 388 1996 411 1997 373 4.87 4.47 4.64 3.5 3.7 3.11 2.87 2.79
Year/Unit.Years
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Best Quartile Values
100 94.98
92.82
92.42
93.43
94.29
85
80
75
70 1990 412 1991 441 1992 438 1993 400 1994 379 1995 388 1996 411 1997 373
Year/Unit.Years
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Best Quartile Values
10 9 8 7 percent 6 5 4 3 2.12 2 1 0 1990 412 1991 441 1992 438 1993 400 1994 379 1995 388 1996 411 1997 373 2.07 1.97 1.66 1.7 1.32 1.4 1.42
Year/Unit.Years
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Average Values Balanced by Power
100 90.91 89.67 90 80 70 percent 60 50 40 30 20 10 0 X 244 X 174 X 74 X 105 X 67 X 933 X 105 X 422 X 681 X 19 X 256 X 14 X 63 X 82 X 3 Set 3242 44.85 87.07 84.89 84.66 84.45 84.19 82.41 81.07 79.55 74.03 73.81 68.76 67.24 82.83
Country/Unit.Years
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Average Values Balanced by Power
100 90 80 70 percent 60 50 40 30 20 10 0 X 82 X 105 X 256 X 422 X 67 X 63 X 681 X 933 X 74 X 105 X 174 X 244 X 14 X 19 X 3 Set 3242 15.71 9.07 7.99 7.84 6.42 5.49 5.36 5.19 4.5 4.27 4.22 3.83 3.02 6.18 2.09 0.13
Country/Unit.Years
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Median Values
100 90 80 70 60 percent 50 40 30 20 10 0
89.41 89.13 88.84 88.53 88.4287.1 88.35 88 88.988.57 87.75 87.37 86.93 86.96 86.75 86.59 86.44 86.33 86.3885.5 86.586.15 86.12 86.2 85.99 85.94 85.79 85.74 85.64 85.51 85.5 86.3 85.5
1 28
2 35
3 49
4 55
5 67
6 78
7 83
8 90
9 92
10 100
11 101
12 101
13 93
14 99
15 108
16 112
17 114
18 109
19 127
20 134
21 136
22 126
23 120
24 118
25 118
26 123
27 107
28 98
29 88
30 86
31 80
32 70
33 58
Year old/Unit.Years
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Median Values
10 9 8 7 6 percent
5.04
5
4.22 4 3.7
4.7 4.4 4.14 3.7 3.33 3.04 2.8 2.68 2.78 2.72 3 4.04 3.64 3.58 3.98 3.89 3.96 4.12 3.58 3.22 4.1 4.43
4.68 4.05
4.7
4 3 2 1 0
3.63 3.36
3.7
3.52
1 28
2 35
3 49
4 55
5 67
6 78
7 83
8 90
9 92
10 100
11 101
12 101
13 93
14 99
15 108
16 112
17 114
18 109
19 127
20 134
21 136
22 126
23 120
24 118
25 118
26 123
27 107
28 98
29 88
30 86
31 80
32 70
33 58
Year old/Unit.Years
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - 100/199 MW - (1990 to 1997) Distribution
Median 87.16 250 230 220 200 Best Quartile 93.03
180
number of units
150
127
100
51 50 21 5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 2 0 4 0 0 8 8 8 10 17 33
51
75
80
85
90
95
100
percent
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - 100/199 MW - (1990 to 1997) Distribution
Best Quartile 1.7 700 600 500 400 300 233 200 100 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 85 36 13 8 7 4 2 3 1 4 0 0 1 0 0 0 0 0 1070 Unit.Years Arith. Mean=5.89 673 Median 3.7
number of units
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - 200/399 MW - (1990 to 1997) Distribution
Median 87.04 300 292 Best Quartile 92.6 289
250 number of units 192 1413 Unit.Years Arith. Mean=82.43 150 124
231
200
100 45
78 38 7 3 10 4 15 3 20 4 25 5 30 7 35 13 13 20 20 25
50
0 5 40 45 50 55 60 65 70 75 80 85 90 95 100 percent
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - 200/399 MW - (1990 to 1997) Distribution
Best Quartile 1.5 900 800 700 number of units 600 500 400 300 200 100 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 130 46 16 14 4 4 1 1 2 1 2 327 1413 Unit.Years Arith. Mean=5.61 865 Median 3.5
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - 400 to 599 MW - (1990 to 1997) Distribution
Median 85.25 90 80 70 61 number of units 60 50 40 30 21 20 11 10 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 1 1 4 5 1 0 1 0 7 11 25 27 446 Unit.Years Arith. Mean=80.77 43 85 76 66 Best Quartile 91.6
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - 400 to 599 MW - (1990 to 1997) Distribution
Best Quartile 2.29 248 250 Median 4.1
150
100
50
44 32 12 6 30 4 35 5 40 4 45 0 50 0 55 0 60 0 65 0 70 2 75 0 80 0 85 0 90 0 95 0 100
0 5 10 15 20 25 percent
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - P>=600 MW - (1990 to 1997) Distribution
Median 87.6 80 71 70 60 number of units 50 40 30 20 11 10 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 0 0 0 0 0 0 1 2 5 4 2 13 17 313 Unit.Years Arith. Mean=84.59 42 34 47 64 Best Quartile 93.9
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - P>=600 MW - (1990 to 1997) Distribution
Best Quartile 1.65 199 200 Median 3.45
number of units
56 50 27 10 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 11 6 2 0 1 1 0 0 0 0 0 0 0 0 0 0
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Coal - (1990 to 1997) Distribution
Median 87.13 400 350 300 number of units 250 200 150 100 59 50 3 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 2 2 6 1 5 6 10 7 22 23 25 66 84 1686 Unit.Years Arith. Mean=83.26 156 373 354 Best Quartile 92.6
266 216
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Coal - (1990 to 1997) Distribution
Best Quartile 1.9 996 1000 Median 3.91
600
400
200
156 72 39 22 30 11 35 8 40
5 45
4 50
1 55
2 60
0 65
0 70
2 75
0 80
0 85
0 90
0 95
1 100
0 5 10 15 20 25 percent
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Coal - (1990 to 1997) Median Values
100
95 89.91 90.63
88.89
80
75
70 1990 222 1991 243 1992 230 1993 202 1994 190 1995 193 1996 217 1997 189
Year/Unit.Years
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Coal - (1990 to 1997) Median Values
10 9 8 7 percent 6 5 4 3 2 1 0 1990 222 1991 243 1992 230 1993 202 1994 190 1995 193 1996 217 1997 189 3.7 3.78 3.2 3 2.84 5.39 4.93 5.11
Year/Unit.Years
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Coal - (1990 to 1997) Median Values
100 90 80 70 percent 60 50 40 30 20 10
94.74
92.1
91.9
89
87
0 X 0 Set 1686
Country/Unit.Years
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Coal - (1990 to 1997) Median Values
100 90 80 70 percent 60 50 40 30 20 11.1 10 0 X 65 X 63 X 32 X 422 X 123 X 24 X 497 X 104 X 149 X 159 X 28 X 6 X 14 X 0 X 0 Set 1686 6.9 4.9 4.74 4.5 4.25 4.06 3.3 3 2.63 2.53 1.26 1.15 3.91 0 0
Country/Unit.Years
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Lignite and Others - (1990 to 1997) Distribution
Median 86.91 180 163 160 140 number of units 120 101 100 80 63 60 40 20 2 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 2 2 3 2 2 7 8 13 6 5 12 18 36 26 721 Unit.Years Arith. Mean=82.8 Best Quartile 94.44
127
123
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Lignite and Others - (1990 to 1997) Distribution
Best Quartile 2.07 450 400 350 number of units 300 250 206 200 150 100 58 50 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 18 2 3 1 0 0 0 0 0 0 0 0 0 0 0 0 0 721 Unit.Years Arith. Mean=5.09 433 Median 3.84
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Lignite and Others - (1990 to 1997) Median Values
100
80
75
Year/Unit.Years
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Lignite and Others - (1990 to 1997) Median Values
10 9 8 7 percent 6 5.08 5 4 3 2 1 0 1990 87 1991 87 1992 95 1993 92 1994 89 1995 91 1996 92 1997 88 4.47 4.72 3.43 3.77 3.91 3.1 3.46
Year/Unit.Years
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Liquid Fuels - (1990 to 1997) Distribution
Median 84.3 Best Quartile 91 106 100 96
number of units
75
60
55
58
40 30 20 6 1 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 1 2 2 2 2 5 8 9 15 5 18
37
75
80
85
90
95
100
percent
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Liquid Fuels - (1990 to 1997) Distribution
Best Quartile 0.78 Median 2.5 356 350 300 number of units 250 200 150 100 50 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 533 Unit.Years Arith. Mean=5.74
72 56 22 8 6 4 3
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Liquid Fuels - (1990 to 1997) Median Values
100
95
88.95
75
Year/Unit.Years
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Liquid Fuels - (1990 to 1997) Median Values
10 9 8 7 percent 6 5 4 3 3 2 1 0 1990 62 1991 67 1992 76 1993 70 1994 69 1995 70 1996 65 1997 54 2.4 2.5 1.84 1.7 1.15 4.3
Year/Unit.Years
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Gaseous Fuels - (1990 to 1997) Distribution
Median 88.4 80 73 70 60 number of units 50 40 30 22 20 13 10 1 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 1 0 0 0 1 0 0 2 6 8 5 12 16 302 Unit.Years Arith. Mean=83.32 30 58 54 Best Quartile 93.6
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - Gaseous Fuels - (1990 to 1997) Distribution
Best Quartile 1.4 200 200 Median 3.36
number of units
Unit Capability Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Comb. Cycle or Cogen. - All Fuels - (1990 to 1997) Distribution
Median 85.07 51 50 46 39 Best Quartile 90.6
40 number of units
30
20 12 10 5 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 0 1 1 0 2 0 3 3 4 3 5 14
Unplanned Capability Loss Factor AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Comb. Cycle or Cogen. - All Fuels - (1990 to 1997) Distribution
Best Quartile 1.93 140 125 120 Median 4.54
80
71
60
40 16 6 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 percent 3 6 1 0 1 1 0 0 0 0 0 0 0 0 0 0
20
Unplanned Automatic Grid Separation per 7000 hr (TOH >=1000) AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Distribution
Best Quartile 2.3 1000 955
Median 5.2
6 50
1 55
1 60
Unplanned Automatic Grid Separation per 7000 hr AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Median Values
14 12 9.9 10 8 6.5 6 4 2 0 1990 237 1991 286 1992 279 1993 211 1994 237 1995 228 1996 258 1997 227 5.3 4.4 4.35 3.7 3.5 7.7
Year/Unit.Years
Unplanned Automatic Grid Separation per 7000 hr AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Average Values
14 12.28 12 10.63 9.99 10 8 6.38 6 4 2.15 2 0 0 X 74 X 255 X 671 X 1 X 37 X 33 X 106 X 67 X 189 X 423 X 91 X 0 X 16 X 0 X 0 Set 1963 0 0 0 5.94 5.7 4.02 9 8.7 8.22 7.63
Country/Unit.Years
Unplanned Automatic Grid Separation per 7000 hr AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Median Values
12
10
7 6.4 5.8 5.35 4.55 5.1 4.6 6.15 5.7 4.9 5.8 4.6 5.95 5.55 5 4.45 4.7 4.5 5.3 4.8 4.9 4.7 5.7 5.8 4.95 4.7 4.3 6.1 5.5 5.55 5.5
1 15
2 17
3 28
4 36
5 43
6 53
7 55
8 57
9 57
10 68
11 72
12 72
13 66
14 64
15 70
16 74
17 82
18 80
19 80
20 83
21 77
22 79
23 85
24 73
25 72
26 71
27 61
28 47
29 46
30 42
31 35
Year old/Unit.Years
Unplanned Automatic Grid Separation per 7000 hr (TOH >=1000) AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Comb. Cycle or Cogen. - All Fuels - (1990 to 1997) Distribution
Best Quartile 0 45 40 35 number of units 30 25 20 15 10 5 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 number of grid separations per 7000 hours 14 15 82 Unit.Years Arith. Mean=7.75 39
Median 6
7 1
Successful Startup Rate AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Distribution
Median 94.74 256 250 Best Quartile 100
150
Industrial Safety Accident Rate AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA All installations - All Fuels - (1990 to 1997) Distribution
Best Quartile 5.6 400 350 300 number of units 250 200 149 150 100 52 50 0 5 10 15 20 25 30 35 40 45 50 55 60 Industrial Safety Accident Rate 30 39 36 15 11 5 0 242 1237 Unit.Years Arith. Mean=12.31 391 Median 9.9
267
Industrial Safety Accident Rate AT/BE/CH/CZ/DE/DK/ES/FR/HU/IE/IL/IT/NL/PT/ZA Steam Turbine - All Fuels - (1990 to 1997) Distribution
Best Quartile 5.48 400 362 350 300 number of units 250 200 150 100 50 0 5 10 15 20 25 30 35 40 45 50 55 60 Industrial Safety Accident Rate 42 23 31 33 12 10 3 0 136 Median 9.3
225
Publications Order Form Name: ................................ ................................ ................................ ................................ ............... Position:................................ ................................ ................................ ................................ ............ Company: ................................ ................................ ................................ ................................ ......... Address: ................................ ................................ ................................ ................................ ............ Town: ................................ ....................... Country:................................ ................................ .......... (with postal code) Telephone: ................................ ....................... Fax:................................ ................................ .......... (with international & regional code) UNIPEDE/EURELECTRIC member: Reference No. Title1 p Yes p No (Tick the appropriate box) Quantity
To be returned to:
Concetta PALERMO UNIPEDE/EURELECTRIC Documentation Boulevard de l Impratrice, 66 - Bte 2 BE 1000 Brussels BELGIUM E:mail: cpalermo@unipede.org Web: http://www.unipede.org
Tel.: Fax:
+ 32 2 515 10 00 + 32 2 515 10 10
Some documents are available in two or three languages: DE German, EN English, FR French. Please indicate the language of your choice, when possible.