Application Note 51245 (Revision NEW, 11/2004)

Original Instructions

505 / 505E Features and Functions

Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward is believed to be correct and reliable. However, no responsibility is assumed by Woodward unless otherwise expressly undertaken.

Copyright Woodward 2004 All Rights Reserved

505 / 505E Features and Functions

Application Note 51245

505 / 505E Features and Functions


Features
Original 505/505E (19851994)
Monitor Mode Hand Valve Control Function Keys Tunables Start Permissives External Shutdown Extr/Adm Priority Select Local/Remote Discrete I/O Monitoring Relay Testing Analog Monitoring Analog Calibration Graphics PC Interface No Program Monitor Mode Hand Valve Actuation on Actuator Position No Programmable Function Keys 11 On-Line Program Tunables No Start Permissive 1 External Shutdown Input Auto Extraction Priority Select (505E) N/A N/A N/A N/A N/A N/A N/A

Enhanced 505/505E (1994May, 1996)

New Style 505/505E (May, 1996present)

Program Monitor Mode while Program Monitor Mode while Running Running Hand Valve Actuation on Actuator Position No Programmable Function Keys 18 On-Line Program Tunables Start Permissive Function 1 External Shutdown Input Bumpless Auto Extraction Priority Select (505E) N/A N/A N/A N/A N/A N/A N/A Hand Valve Actuation on Act Position or First Stage Press 2 Programmable Function Keys 100+ On-Line Program Tunables Start Permissive Function 5 External Shutdown Inputs with First Out Indication Bumpless Auto Extraction Priority Select (505E) Selectable Local/Remote Control Contact Input and Relay Output Monitoring Relay Output Forcing (Test) Analog Input and Output Monitoring Analog Input and Output Calibration Optional Graphic Display Panel Optional PC/Windows Programming Interface

Operational Modes
Operational Modes Extr/Adm Ctrl (505E) Ratio/Limiter (505E) Run & Program Extraction Control Coupled HP & LP Run & Program Extr & Admission Control Coupled HP & LP Run, Program, Service Extr & Admission Control Coupled HP & LP DecoupledInlet DecoupledExhaust Decoupled HP & LP Synch or Isochronous Load Sharing with DSLC

Synch/Load Sharing Dynamics Start Sequence

No Synch or Load Sharing Single Set of Dynamics (Speed PID) Manual, Idle/Rated Start Sequence

Isochronous Load Sharing With DSLC

Dual Dynamics (Speed PID) Dual Dynamics (Speed PID) Manual, Idle/Rated Start Sequence Manual, Idle/Rated, Auto Start Sequence with Hot or Cold Start CascadePID Control Auxiliary PID as a Limiter or Controller (505/505E) Speed Setpoint Extr/Adm Setpoint (505E) Auxiliary Setpoint Cascade Set point

Cascade Auxiliary Loop 420 mA Remote Setpoint

CascadeDeadband Control CascadeDeadband Control Auxiliary PID as a Limiter (505) Speed Setpoint Auxiliary PID as a Limiter (505) Speed Setpoint

Woodward

Application Note 51245

505 / 505E Features and Functions

Operational Modes (continued)


Communication 1 Communication Port RS-232 Fixed Program 3009600 Baud 1 Communication Port RS-232 Fixed Program Modbus RTU or ASCII 3009600 Baud 2 Communication Ports RS-232 / RS-422 / RS-485 Modbus RTU Or ASCII 30057 600 Baud

Hardware
Original 505/505E (19851994)
Microprocessor Display Termination Dimensions 16 Bit Zilog (Z-8000) LCD 2 Line Display (22 characters per line) Attached Terminal Blocks 22.5H x 18.5W x 9.0D (572 x 470 x 229 mm) Enclosure 27 Key Front Service Panel N/A

Enhanced 505/505E (1994May, 1996)


16 Bit Zilog (Z-8000) LCD 2 Line Display (22 characters per line) Attached Terminal Blocks 22.5H x 18.5W x 9.0D (572 x 470 x 229 mm) Enclosure 27 Key Front Service Panel N/A

New Style 505/505E (May, 1996present)


32 Bit Motorola (68332) LED 2 Line Display (24 characters per line) Removable Terminal Blocks 11.0H x 14.0W x 4.0D (279 x 356 x 102 mm) Enclosure 30 Key Front Service Panel Flush Mount Kit (8923-134) Bulkhead Mount Kit (8923-135)

Keypad Retrofit Mounting Kit to replace older 505/505E with new style 505/505E

I/O
Speed Sensing (2) MPUsPassive Only (350 Hz to 12 kHz) (4) Analog InputsFixed (2) MPUsPassive Only (350 Hz to 12 kHz) (4) Analog InputsFixed (2) MPUs, Proximity Probes or one of each (0.5 Hz to 15 kHz) (6) Analog Inputs Programmable (10+ choices) (16) Contact Inputs (4 fixed, 12 programmable) (26+ choices) Selectable 2 Actuator Outputs (420 mA and/or 20160 mA) 6 Analog Outputs (420 mA) Act#2 as Analog Output #7 (17+ choices) 8 Contact Outputs (2 fixed, 6 programmable) (30+ choices)

Analog Inputs

Discrete Inputs

16 Contact Inputs (6 fixed, 10 programmable) (13 choices) Selectable 2 Actuator Outputs (420 mA Or 20160 mA) 4 Analog Outputs (420 mA) (11 choices) 8 Contact Outputs (3 fixed, 5 programmable)

16 Contact Inputs (6 fixed, 10 programmable) (15 choices) Selectable 2 Actuator Outputs (420 mA Or 20160 mA) 4 Analog Outputs (420 mA) (11 choices) 8 Contact Outputs (3 fixed, 5 programmable) (11 choices)

Actuator Outputs

Analog Outputs

Discrete Outputs

Protection
Security Program SecurityHardware Program SecurityHardware Program SecurityPassword Jumper Jumper

Woodward

We appreciate your comments about the content of our publications. Send comments to: icinfo@woodward.com Please reference publication

51245.

PO Box 1519, Fort Collins CO 80522-1519, USA 1000 East Drake Road, Fort Collins CO 80525, USA Phone +1 (970) 482-5811 Fax +1 (970) 498-3058

Email and Websitewww.woodward.com Woodward has company-owned plants, subsidiaries, and branches, as well as authorized distributors and other authorized service and sales facilities throughout the world. Complete address / phone / fax / email information for all locations is available on our website.