Vous êtes sur la page 1sur 15

Solucin Small Cells para cobertura y capacidad

Nokia Siemens Networks 2011

Small Cells to Adress Coverage and Capacity

Nokia Siemens Networks 2011

Coverage Gaps / Traffic Hotspots


Coverage gap or holes

Traffic hot spots


Need to improve coverage or add capacity on traffic hot spots

Broadband coverage

GSM covera ge

Broadband coverage

Planning and Optimization needed for layering

Nokia Siemens Networks 2011

Small Cell for Capacity


Micro-cell coverage depends on the isolation from the macro-cell
Macrocell RSCP level [dBm]
-85 -75 -65 -55

Place the micro cell as close as possible to the centre of the traffic hotspot
On average micro-cell will offload 20% to 30% from the macro cell traffic To minimize Soft Handover overhead, try to find the highest possible isolation from the macro layer Micro cell can share the same frequency with the overlapping macro cell

On street cochannel 3G microcell radius [m] < 200 100 75 < 50

Nokia Siemens Networks 2011

The Flexi Multiradio BTS


3 main building blocks to a complete GSM/WCDMA/LTE Site

Highest integration density level GSM/EDGE/WCDMA/HSPA/LTE


defined by SW

Flexi 3 sector RFM (GSM/WCDMA/LTE)

Dedicated and concurrent mode Single Band units: 850, 900, 1800, 1900 60W output per sector with
Multi Carrier Power Amplifier (MCPA)

Flexi EDGE 18/36 TRX System Module

High Capacity (18/36 TRX) Multiband support Optimized for GSM/EDGE

Multimode System Module (WCDMA/LTE)

Flexi 3-Sector RF Module (GSM/WCDMA/LTE)


1 Gbps throughput Multiband support Multimode support Dedicated and concurrent mode SW defined

Flexi EDGE 18/36 TRX System Module Multimode System Module (WCDMA/LTE)

Nokia Siemens Networks 2011

RF Sharing WCDMA - GSM


RX Diversity Sharing WCDMA-GSM (Phase 1)
GSM and WCDMA use dedicated
RF modules
RG10
GSM SM
RFM1
TX Duplexer

MCPA
RX main RXMC

LNA

RX

One System Module per technology Share antenna system diversity between the 2 RFMs is shared using RX
Div output connector
GSM up to 6+6+6 TRX @ 10W WCDMA 1+1+1 @ 40W
WCDMA SM

RX div

LNA

RFM2
TX Duplexer

MCPA
RX main RXMC

LNA

RX

RX div

LNA

RU20
RX Diversity Sharing
X

RG10

RF Sharing WCDMA-GSM (Phase 2)


Shared RF module for GSM and WCDMA One System Module per technology Share antenna system
GSM up to 2+2+2 TRX @ 10W WCDMA 1+1+1 @ 40W
GSM SM
TX

RFM1
Duplexer

MCPA
RX main RXMC

LNA

RX

RX div

LNA

WCDMA SM

RF Sharing

RU30
6 Nokia Siemens Networks 2011

Flexi Multiradio BTS: 2G + 3G BTS


Shared Antenna: GSM 2+2+2 TRX @ 10W WCDMA 1+1+1 @ 40W
RM 1900 (FXFA)
FPRA or FPMA

Distributed Solution: - Local Power Supply - Singlemode Fiber

Fiber up to 10Km

Feederless Solution: - DC power from SM - 50m, 100m or 200m fiber


2G SM (ESMC)

Fiber up to 200m
RM 1900 (FXFA)

RP3 Cable for SM Sync

3G SM (FSME) Power (FPRA)

DC Cable

License needed for RF Sharing


7 Nokia Siemens Networks 2011

Flexi Multiradio BTS: 3G + LTE BTS


Separated Antenna: LTE 1+0+0 @ 20MHz MIMO WCDMA 1+1+1 @ 40W
RM 2600 (FRHA)

RM 1900 (FXFA)
FPRA or FPMA

Distributed Solution: - Local Power Supply - Singlemode Fiber

Fiber up to 10Km

Feederless Solution: - DC power from SM -50m, 100m or 200m fiber - Multimode Fiber
RM 2600 (FRHA) RM 1900 (FXFA)

LTESM (FSME)

Fiber up to 200m

RP3 Cable for SM Sync

3G SM (FSME) Power (FPRA)

DC Cable

SM FSME Supports up to 3 RM
8 Nokia Siemens Networks 2011

Flexi Multiradio BTS Remote RF Heads


2010 2011 2012 2013
2100 (FRGV)**

WCDMA/ LTE: RRH 2TX/2RX 40W + 40W

3Q/12 HW

2600 (FRHB)
available 3Q/11 (LTE RL30)

GSM / WCDMA / LTE: RRH 2TX/4RX 60W + 60W

850 (FHCD)**
4Q/13 HW RU50/RL60

1900 (FHFA)**
4Q/13 HW RU50/RL60

Planned HW availability Planned SW release **) Sw release info under study

Actual availability and Sw support depends on market needs and customer orders.
Nokia Siemens Networks 2011

Flexi Multiradio BTS: LTE BTS (Remote Radio Head)


LTE 1+0+0 @ 20MHz

Distributed Solution: - Local Power Supply - Singlemode Fiber


AC/DC (FFAC) For direct AC feeding

Fiber up to 15Km

Fiber up to 200m
LTE SM (FSME) Power (FPRA)

Feederless Solution: - DC power from SM - 50m, 100m or 200m fiber - Multimode Fiber

DC Cable

10

Nokia Siemens Networks 2011

RF Chaining

RG20

or

RU30

Efficient highway coverage and roof top solution


RF Chaining support with 3-Sector RF modules or RRHs Single and dual-band chaining Smooth site extension to dual-band e.g. 1900 MHz and 850 MHz Supports also MIMO, Dual-Cell HSPA and I-HSPA configurations Up to 12 RF modules or RRHs and per BTS Up to 12 carriers per BTS Up to 2 RF modules or RRHs per one chain Up to 6 carriers per chain Flexibility for building indoor coverage

Max 10km Max 10km

850 MHz
850 MHz 1900 MHz 1900 MHz

RFM

RFM

RFM

RFM
1900 MHz

SM
System Module
11 Nokia Siemens Networks 2011

850 MHz

RF Chaining with RF Sharing GSM-WCDMA

RG30

and

RU50

Flexible GSM-WCDMA site building and upgrading

RF Chaining with RF Sharing support for


3-Sector RF modules or RRHs

One chain for RF-shared units Single-RAT chain can be added to both GSM
or WCDMA system module

900 MHz GSM/WCDMA 900 MHz GSM/WCDMA 900 MHz GSM/WCDMA

One chain can support up to 6 WCDMA carriers


together with GSM TRX
max 6 WCDMA(2+2+2) carriers +6 GSM carries(2+2+2) or max 3 WCDMA(1+1+1) carriers +18 GSM carries(6+6+6)

GSM system module WCDMA system module

RFM

RFM

RFM

SM SM

12

Nokia Siemens Networks 2011

Power Backup System for Flexi Multiradio BTS


Power System for Flexi Multiradio BTS
New model, with a battery box to install
battery. Up to 3 FRPA rectifier (2kW each). 3U Flexi case

450mm

650mm 685mm

13

Nokia Siemens Networks 2011

Power System for Radio Modules

Rectifiers power from 230VAC to 48VDC


(FPAA) Battery Backup Li-Fe (FPBB) Usable for GSM/EDGE/LTE/WCDMA base stations Needs 3U Flexi Power case (FPMA)

Compact stand alone 500W AC/DC power


supply unit for RRH products Can be attached to all NSN 2TX RRHs Wide AC input range 90276VAC with 55VDC output IP65 Ambient temperature range -3555C with sun load to the FPKA pole mounting kit underneath RRH

14

Nokia Siemens Networks 2011

Flexi Multiradio Power Consumption

Power Consumption examples for various Power levels

Sys Module + Others 8W 8W 8W - chain 8W 8W 40W 40W 8W 3G BTS 1900 (FXFA+FSME) 3G BTS 1900 (FXFA+2xFSME) 3G BTS 1900 (2xFXFA+FSME) 3G BTS 1900 (3xFXFA+FSME) 3G BTS 1900 (3xFXFA+2xFSME) 3G BTS 1900 (3xFXFA+FSME) 3G BTS 1900 (3xFXFA+2xFSME) LTE BTS RRH (3xFRHB+FSME)

RF Module 50% load 344 344 416 622 622 771 771

RF Module 100% load 382 382 440 660 660 909 909 159

Total PW consumption 50% load [W]

Total PW consumption 100% load [W]

248 468 248 248 468 248 468 263

592 812 664 870 1090 1019 1239

630 850 688 908 1128 1157 1377 422

15

Nokia Siemens Networks 2011

Vous aimerez peut-être aussi