Académique Documents
Professionnel Documents
Culture Documents
Redundant
LAG
Modular Functionality
10/100 Mbps Ethernet
The Cajun P330 Stackable Switching
10/100 Mbps Ethernet
System provides unique modular
functionality in stackable form and at
Gigabit Ethernet
a workgroup stack price. with LAG
Port Density
The Cajun P330 is designed to
support up to 640 10/100Base-Tx, 10/100 Mbps Ethernet
Stackable Switch without disrupting The Cajun P330 VLANs are fully IEEE
operation or 802.1Q compliant and can handle up
With the increasingly performing stack-level to 3k tagged VLANs.
important role of reconfiguration. You
networks in today’s *future
Priority Protocol. This protocol detects and Remote Access
The Cajun P330 supports eight levels eliminates logical loops in the You can operate the CLI from a
of priority tags through two priority network and automatically places terminal or computer which is
queues and supports IEEE 802.1p some ports on standby to form a connected to the P330 via secure
tagging. network with the most efficient Telnet through the “Master Agent” or
pathways. through the serial interface.
LAG – Link Aggregation Group
IP Multicast*
LAG provides increased bandwidth
The Cajun P330 will support IP Network Monitoring
and redundancy for critical high-
bandwidth applications such as inter- Multicast filtering with IGMP SMON
stack links and connections to servers. snooping in future products. This
The Cajun P330 supports Lucent’s
filtering provides more efficient
You can aggregate the bandwidth of ground-breaking SMON Switched
switching of IP multicast traffic e.g.,
up to eight 10/100Base-Tx ports, two Network Monitoring, which the IETF
from a video server or the Internet.
100Base-FX or 1000Base-X ports to has now adopted as a standard
provide a single full duplex high- (RFC2613). SMON provides an
Network Management unprecedented top-down monitoring
speed link of up to 4 Gbps.
Lucent realizes the importance of of switched network traffic at the
Load sharing ensures that if one of comprehensive network management following levels:
the port connections fails, the other as a key component of today’s
connections will assume the load networks. Therefore we have Protocol Distribution
seamlessly. provided multiple ways of managing
Load balancing guarantees that the the Cajun P330 to suit your needs.
traffic load at any level will be evenly Cajun P330 Manager
Subnet/Network Monitoring
(Subnet Statistics)
divided among all the LAG links.
Cajun P330 switches come with free
Congestion Control management software as standard. User
Monitoring
Congestion control is a key element This program, which uses the Lucent (Host
Statistics)
of maintaining network efficiency as CajunView™ graphical interface,
it prevents resource overload. allows you to manage a Cajun P330
stack without purchasing additional
The Lucent Cajun P330 supports This top-down approach gives you
software.
congestion control on all Ethernet rapid troubleshooting and
ports, using the following: CajunView
performance trending to keep the
● Back Pressure in half duplex mode. When you need extra control and network running optimally.
monitoring or wish to manage other
● IEEE 802.3x Flow Control in full RMON
Cajun Campus equipment, then the
duplex mode. The Cajun P330 supports the
CajunView network management
Auto-Negotiation suite is the answer. This suite standard RMON groups 1, 2, 3 and 9:
Every 10/100 port on the Cajun P330 provides the ease-of-use and features ● Statistics
supports Auto-Negotiation which necessary for optimal network
● History
automatically detects and supports utilization.
the operating mode and speed of a ● Alarms
Web Management*
connected device. Auto-negotiation is ● Events
The Cajun P330 will also support
also supported on the Gigabit Port Mirroring
embedded Web management so you
Ethernet ports.
can manage P330 stacks using a The Cajun P330 provides port
This means that you can simply standard browser from anywhere on mirroring for additional network
connect the Cajun P330 to Ethernet the network. monitoring functionality. You can
or Fast Ethernet equipment at full or filter the traffic by VLAN and mirror
CLI
half duplex without configuration. either incoming traffic to the source
The Cajun P330 CLI (command line
Spanning Tree port or both incoming and outgoing
interface) is consistent with other
The Cajun P330 supports the IEEE traffic. This allows you to monitor the
Cajun Campus products for greater
802.1D standard Spanning Tree network traffic you need.
ease of use. *future
Multilayer Switching* Reliable Routing Multilayer Network Management
Lucent has extended SAFER and Monitoring
Adding Multilayer switching to a
Cajun P330 stack is as simple as technology to the Cajun P330R in You can manage the the Cajun P330R
plugging in a Cajun P330R. This router mode. The P330R supports with the Router Manager. The Cajun
switch not only provides all the OSPF which allows a number of paths P330R is also manageable by the
Layer 2 benefits of the Cajun P330 to be defined and supports VRRP CajunView network management
switching family, but also adds which gives router redundancy. system and is fully integrated with
Layer 3 and Layer 4 switching for an Policy-based Switching RealNet Rules for policy
entire stack. management.
Since the Cajun P330R is a multilayer
The multilayer switching uses the switch, it can enforce centralized It is also possible to configure and
information within the Ethernet network policies using RealNet Rules monitor the P330R using the CLI .
packets in combination with policy management. The CLI can be accessed in a number
RealNet Rules policy management to of ways for maximum flexibility:
The Cajun P330R can enforce policy through secure Telnet directly to the
provide end-to-end QoS. The Cajun
per packet or per flow according to P330R IP address, by secure Telnet
P330R tags packets with QoS
four criteria: the IEEE 802.1p priority through the “Master Agent” or
according to the application and
tag in the incoming packet, the Diff- directly through the serial interface.
policy of the packet. As a true
Serv byte (TOS field) in the IP header
routing-capable switch, the Cajun The P330R supports a Cajun P550-
of the incoming packet,the packet's
P330R enforces access rules on IP like CLI for ease of use and
source or destination IP address
packets. consistency with other members of
matching a configured priority policy
The Cajun P330R has two modes of and the packet source or destination the Cajun Campus.
operation: Router and EZ2route. TCP/UDP port number being in a SMON II
Routing Mode predefined range. The Cajun P330R also features
The Cajun P330R can function as a Policy is enforced by the Cajun P330R unique SMON II (RMON II) hardware
regular LAN IP router and it supports according to the support. After SMON
source and SMON II Top-Down Monitoring was established as a
the necessary routing protocols such
as RIP, OSPF, ARP, ICMP and destination of the standard, Lucent is now
Protocol Distribution
DHCP/BOOTP relay for plug and play application and working on SMON II,
IP connectivity to DHCP clients. according to the the next generation of
application type. Each Lucent switched network
EZ2route Mode Subnet/Network Monitoring
(Subnet Statistics)
packet is allocated the right monitoring. It brings SMON
Lucent EZ2route technology employs priority and QoS. capabilities to Layer 3.
the power and simplicity of the Cajun
User SMON II allows you to monitor
P330R system for routing. Monitoring
(Host
Statistics) protocol distribution and provides
The P330R performs Layer 3 information on individual IP hosts
switching functions without requiring and matrices of IP traffic. *future
the administrative overhead
associated with regular routers. Cajun P330
Cajun P330
Cajun P550
known to the stations as their router, Internet
Video Server
Cajun P330R Multilayer Switch
ATM Access* Cajun P330 Cajun P330
ATM
OC-12 Cajun M770
Multifunction Switch
Internet:
e-mail: cajuninfo@lucent.com
http://www.lucent.com/dns
Cajun, CajunView, EZ2route, Octaplane, RealNet, RealNet Rules and SAFER are trademarks of Lucent Technologies, Inc.
All other trademarks, registered trademarks, service names, product and/or
brand names are the sole property of their respective owners. This document
is for planning purposes only and is not intended to modify or supplement
any specifications or warranties relating to these products and services.
© 1999 Lucent Technologies. All rights reserved.
*future E6360. 9/99