Instrumentation Cables; BS5308 These cables are for instrumentation applications. Designed for on-shore use, they are made with PVC or Polyethylene insulations, and PVC outer sheaths. They are available with or without a galvanized steel wire armor for protection in harsh environments. For Zone 1 and 2 applications, per EN 60079-14, these cables must meet the flame retardance specifications of IEC60332. For data sheets click here. BS 6883 These cables are for instrumentation, control, and power applications. Designed for rugged use, they are typically made with EPR insulation, SW4 outer sheath, and with or without a galvanized steel wire braid for harsh environments. For Zone 1 and 2 applications, per EN 60079-14, these cables must meet the flame retardance specification of IEC60332. For data sheets click here. BS7917 These cables are very similar to BS6883 but also meet the IEC60331 fire resistant specification. Each conductor is insulated with MICA glass tape and are used where circuit integrity is critical. For data sheets click here. NEK 606 RFOU (i) 250V These instrument cables are considered world class cables. The are flame retardant to IEC-60332-3-22. Designed for rugged off-shore applications, they have a EPR insulation, flame retardant halogen-free thermoset compound bedding, a tinned copper wire braid and flame retardant halogen-free and mud resistant thermoset compound. For data sheets click here. BFOU (i) 250V These cables are the same as RFOU except they also meet the fire resistant specification of IEC-60331. For data sheets click here. Power and Control Cables BS 6883 These cables are for instrumentation, control, and power applications. Designed for rugged use, they are typically made with EPR insulation, SW4 outer sheath, and with or without a galvanized steel wire braid for harsh environments. For Zone 1 and 2 applications, per EN 60079-14, these cables must meet the flame retardance specification of IEC60332. For data sheets click here. BS5467 These cables are for power and control applications. Designed for on-shore use, they are made with PVC or XLPE insulations, and either PVC or EPR outer sheaths. They are available with or without a galvanized steel wire armor for protection in harsh environments. For Zone 1 and 2 applications, per EN 60079-14, these cables must meet the flame retardance specifications of IEC60332. For data sheets click here. BS6724 These cables are are very similar to BS5467 cables but are zero halogen. Designed for on-shore use, they are made with LSF inner sheath, Type LTS1 to BS7655 and black LSF outer sheath Type LTS1 to BS7655. They are available with or without a galvanized steel wire armor for protection in harsh environments. For Zone 1 and 2 applications, per EN 60079-14, these cables must meet the flame retardance specifications of IEC60332. For data sheets click here. NEK 606 RFOU 0.6/1kV These power and control cables are halogen-free and mud resistant. They are fire retardant to IEC 60332, have an EPR insulation and a tinned copper wire braid. For data sheets click here. BFOU 0.6/1kV These cable are the same as the RFOU but also meet the fire resistant specification of IEC 60331. For data sheets click here.
1 de 3
20/11/2013 23:51
http://www.exindustries.com/prod_cables.htm
Table of Comparisons AWG/mm2 AWG 18 16 14 12 10 8 6 4 2 1/0 or 0 2/0 or 00 3/0 or 000 4/0 or 0000 250 kcmils 300 kcmils 400 kcmils 500 kcmils 600 kcmils 1000 cmils Approx. mm2 0.75 1.5 2.5 4.0 6.0 10.0 16.0 25.0 35.0 50.0 70.0 95.0 120.0 150.0 185.0 240.0 300.0 500.0
2 de 3
20/11/2013 23:51
http://www.exindustries.com/prod_cables.htm
3 de 3
20/11/2013 23:51