E ng i n e ro om tota l f l o o ding Hi g h pre s su re water mist

As one of the worlds few manufacturer, Danfoss Semco can offer protection of your engine room with a true high-pressure water mist without any additives. The advantage of the Sem-Safe system is that the very small quantities of water it uses are harmless to personnel and equipment. Even electrical equipment is left undamaged, provided that protection is better than IP 22. The Sem-Safe system is approved by all major classification societies IP 23. Consequently, it can replace Halon or can be used as a substitute for traditional CO2 systems.

se M - sa F e WaT e R M is T s Y s T e M

hi G h a N d L ow p R ess U R e co 2 s Y s T e M s

Foa M Fi R e E X T i N G U ishi N G S Y s T e M

d R Y che M ica L powde R F i R e e X T i N G U ishi N G s Y s T e M

How water mist func ti ons


Water mist is water that, at a high-pressure of 100 bar, creates a fine mist or fog. The fine water mist evaporates very quickly and the resulting steam starves the fire of oxygen, suppressing it. At the same time, the water evaporation creates the most efficient form of cooling. In this way, the fire is extinguished both by oxygen suppression and cooling, providing the advantages of both water and gas-based fire fighting. High-pressure systems only create a high pressure during extinguishing. High pressure water mist will cool the areas around hot metal surfaces and the water mist evaporates before it reaches the hot metal. In this way, shock cooling and changes in metal structures can be avoided. Danfoss Semco has been working with high-pressure water mist right from the start. This revolutionary new system is finding its way into more and more application areas, offering an efficient system that is environmentally friendly as well as harmless to users. APPROVaL LeVeLS aND eXPeRIeNCe. We have already seen fires being almost instantly extinguished by the system after its release, thus saving repair costs and off-hire periods.

ITEMS SHOWN OUTSIDE THE FRAMES ARE NOT SEMCO SUPPLY

PUMP UNIT
6 3

FILTER UNIT
UCP 1 4

RESERVOIRTANK
PI-2102

26 7 2 9 8 PI-2100 5 Set @ 115 Barg 25 19

UCP

BACK-UP UNIT

UCP

38 36 WATER SUPPLY 33 32

UCP

XX

40 PS

40

PS
S

20 15 21 23

UCP PT

28 PI ZSO 30

39

39 34

M
22 20

UCP 29 41

37 21 23

31

M
22

UCP

H2O CYLINDER 3 PCS.

N2 CYLINDER 4 PCS.

20

21

23

M
22

UCP

SKID LIMIT

Typical arrangement of section valves in an engine room