Packages Content One IF Combiner unit (includes 1m cables with a pair of TNC connectors) Two metal bands Two Tie wraps This Installation Quick Guide Optional - 5m extension cables (ordered separately) Optional - IF Combiner panel package (ordered separately) - includes: One IF Combiner panel (11 holes are sealed with plastic caps) Two ETSI brackets for 19 rack Eight M3x5 screws
Additional Equipment and Tools Required for Installation A grounding cable with appropriate termination for connecting the indoor unit's ground terminal to the rack or to a ground
connection.
On a pole up to 4 diameter using metal bands In a rack using the IF Combiner panel. Each panel can accommodate 12 IF Combiner units, thus supporting three sectors.
P/N 215709
-1-
October 2010
Rotate
Plastic cap
Figure 4: IF Combiner Panel with Two Units Installed 4 Carefully bend the cables and insert them in the grooves on the panel to maintain easy identification of each cable.
P/N 215709
-2-
October 2010
Attach colored marking tape to the cable for easy identification and maintenance. If the unit is mounted on a pole, use Tie-wraps to bind the cable to the pole. If extension is required, connect an extension cable to both connectors of the same pair.
CAUTION
Do not connect IF cables to the calibration (CAL-1 and CAL-2) connectors.
TNC female
connector to ODU
IF Combiner Installation
Pole Mount (without a panel) In a rack (with a panel)
Refer to Connecting to the Macro Indoor BTS AU - without the Panel, below Connecting to Macro Indoor BTS AU Using the Panel on page 6 Connecting to Macro Outdoor BTS AU (NAU/SAU/DAU) on page 7
2x2 ODU: IF-1 to ODU-1, IF-3 to ODU-2; For a second 2x2 ODU: IF-1 to ODU-3, IF-3 to ODU-4 (see Figure 7) 4x2 ODU: IF-1 to ODU-1,IF-2 to ODU-2, IF-3 to ODU-3, IF-4 to ODU-4 (see Figure 8)
If extension is required, connect an extension cable to both connectors of the same pair.
P/N 215709
-3-
October 2010
2x2 AU-ODU
2x2 AU-ODU
IF 3
IF 3
IF1
IF1
AU-1
AU-2
To ODU 1 To ODU 2
To ODU 1 To ODU 2
To ODU 3
To ODU 4
To ODU 3 To ODU 4
Figure 7: Connecting the 2x2 ODU IF Cables Via IF Combiner to Macro Indoor BTS AU - without Panel
P/N 215709
-4-
October 2010
4x2 AU-ODU
IF 1 IF 2 IF 3 IF 4
AU-1
AU-2
To ODU 1 To ODU 2
To ODU 3 To ODU 4
Figure 8: Connecting the 4x2 ODU IF Cables Via IF Combiner to Macro Indoor BTS AU - without Panel
P/N 215709
-5-
October 2010
1 Connect one end of the IF cable to the TNC connector on the ODU (IF connector). 2 Connect the other end of the IF cable to the designated IF slot according to the labels on the panel (see Figure 9). 3 Connect the IF Combiner pair of TNC connectors (item in Figure 6) to the ODU port at the AU-IDU front panels,
depending on the ODU type.
2x2 ODU: IF-1 to ODU-1, IF-3 to ODU-2; For a second 2x2 ODU: IF-1 to ODU-3, IF-3 to ODU-4 (see Figure 10) 4x2 ODU: IF-1 to ODU-1, IF-2 to ODU-2, IF-3 to ODU-3, IF-4 to ODU-4.
If extension is required, connect an extension cable to both connectors of the same pair.
4 Repeat the connections for each additional sector (up to three sectors). 5 After powerup, verify proper operation through the AU LED indicators.
Connect the pair of connectors to AU-ODU connectors labeled here: to AU1 & to AU2
IF slot - To ODU 1
To ODU 2
To ODU 3
P/N 215709
-6-
October 2010
2x2 AU-ODU
IF 3
IF 1
AU-1
To ODU 1 To ODU 2
AU-2
1 Connect one end of the IF cable to the female TNC connector on the ODU (IF connector). 2 Connect the other end of the IF cable to the female TNC connector on the IF Combiner unit (item in Figure 6). 3 Connect the IF Combiner pair of TNC connectors (item in Figure 6) to the IF ports on the AU front panels (on SAU/DAU/
NAU), depending on the ODU type:
2x2 ODU: IF-1 to IF-1, IF-3 to IF-2; For a second 2x2 ODU: IF-1 to IF-3, IF-3 to IF-4 (see Figure 11 and Figure 12) 4x2 ODU: IF-1 to IF-1, IF-2 to IF-2, IF-3 to ODU-3, IF-4 to ODU-4. (see Figure 13).
If extension is required, connect an extension cable to both connectors of the same pair.
4 Repeat the connections for each additional sector (up to three sectors). 5 Verify proper operation through the AU LED indicators.
P/N 215709 -7October 2010
2x2 AU-ODU
2x2 AU-ODU
IF 3
IF 3
IF 1
IF 1
To IF 4 To IF 3 To IF 1 To IF 2
To IF 1
To IF 2
To IF 3
To IF 4
AU-1
AU-2
DAU
Figure 11: Connecting the 2x2 ODU IF Cables Via IF Combiner to Macro Outdoor BTS DAU
P/N 215709
-8-
October 2010
2x2 AU-ODU
2x2 AU-ODU
IF 3
IF 3
IF 1
IF 1
To IF 1 To IF 2
To IF 1 To IF 2
To IF 3 To IF 4
To IF 3 To IF 4
AU
Figure 12: Connecting the 2x2 ODU IF Cables Via IF Combiner to Macro Outdoor BTS NAU/SAU
P/N 215709
-9-
October 2010
4x2 AU-ODU
IF 2
IF 3
IF 1
IF 4
To IF 4
To IF 2 To IF 3 To IF 1
To IF 2 To IF 3 To IF 4
To IF 1
AU-1(Slave)
AU-2 (Master)
Figure 13: Connecting the 4x2 ODU IF Cables Via IF Combiner to Macro Outdoor BTS DAU
P/N 215709
-10-