27 kV MASTERCLAD Medium Voltage Metal-Clad Switchgear with Type VR Vacuum Circuit Breakers

Class 6055

CONTENTS Description Page Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4

Product Description
RATINGS
16.5 to 27 kV 1200-2000 Amperes Continuous Ratings 16, 25 and 40 kA Symmetrical Interrupting Capacity 125 kV BIL, peak (impulse) dielectric withstand 60 kV, rms 1 minute 60 Hz dielectric withstand NEMA Type 1 Indoor enclosure

APPLICATIONS AND STANDARDS


MASTERCLAD medium voltage metal-clad switchgear is used in a wide variety of switching, control and protective applications including electric utility generation and distribution systems, industrial plants, commercial buildings, hospitals, municipal pumping stations, wastewater treatment plants, transportation systems and pipeline stations. MASTERCLAD offers a standard two-high breaker arrangement, incorporating a series of basic modular units, control packages and instrumentation that can be assembled in combinations as needed to satisfy user application requirements. MASTERCLAD switchgear with VR circuit breakers meets or exceeds the design standards of ANSI, IEEE, NEMA and IEC. The switchgear is tested in accordance with both ANSI C37.20.2 and IEC 298. The VR circuit breakers are tested per ANSI C37.09 and IEC 56.

STANDARD FEATURES
Metal-Clad Switchgear as dened by ANSI C37.20.2 includes: Removable (Drawout) Circuit Breaker Fully Compartmented Construction Grounded Metal Barriers enclose all live parts Automatic Shutters over primary contacts Fluidized-Bed Epoxy Insulated Bus Mechanical Interlocks Disconnect Type Voltage Transformers Fixed Control Power Transformer with Drawout Primary Fuses Grounded Breaker Truck in and between Test-Disconnected and Connected Positions Low Voltage Instrument/Control Compartment isolated from primary voltage areas

2
2000 Schneider Electric All Rights Reserved 1/00

Dimensions
27 kV LAYOUT DIMENSIONS/CONFIGURATION GUIDE
Vertical sections are 36 wide

95.12
(242)

1.75
(44)

95.12
(242)

1.75
(44)

36.35
(923)

36.35
(923)

1.00
(25)

58.25
(1480)

16.06
(408)

1.00
(25)

58.25
(1480)

16.06
(408)

110.50
(2807)

110.50
(2807)

1200/2000 A, 2000/1200 A Circuit Breaker Section

AUX VT/Circuit Breaker Section

95.12
(242)

1.75
(44)

95.12
(242) Bus to Incoming Line

36.35
(923)

1.00
(25)

58.25
(1480)

16.06
(408)

(20)

.80

58.25
(1480)

110.50
(2807)

110.50
(2807)

Blank/Circuit Breaker Section

AUX VT/AUX VT Section

95.12
(242)

95.12
(242) Bus to Incoming Line

1.00
(25)

58.25
(1480)

110.50
(2807)

110.50
(2807)

AUX CPT Section


Dimensions are in inches (millimeters).

Blank/AUX Section

3
1/00 2000 Schneider Electric All Rights Reserved

Ratings
VR 27 kV Vacuum Circuit Breakers Rating Table on Symmetrical Current Rating Basis
Description Preferred Ratings per ANSI C37.06-1997 q Insulation Level Rated Withstand Rated PermisRated VoltInterImpulse sible Max. age rupting Low 1.2 x Tripping Voltage Range Time Freq. 50 s Delay kV rms Factor k Cycles kV kV Y rms Crest Sec. a
27 27 27 27 27 27 1.0 1.0 1.0 1.0 1.0 1.0 3 3 3 3 3 3 60 60 60 60 60 60 125 125 125 125 125 125 2 2 2 2 2 2

Circuit Breaker Catalog Number

Rated Rated Short (Ref.) Cont. Circuit Three Current Current Phase 60 Hz (at rated MVA A rms Max. kV) kA rms

Rated Transient Current Values Recovery Voltage Rated Crest Voltage E2 kV Crest
51 51 51 51 51 51

Rated Time to Crest T2 MicroSec


105 105 105 105 105 105

Maximum Sym. Interrupting Capability kA rms


16 16 25 25 40 40

3 Sec. ShortTime Current Carrying Capability kA rms


16 16 25 25 40 40

Close and Latch Rating Momentary kA Crest f


43 43 68 68 108 108

VR2701612 VR2701620 VR2702512 VR2702520 VR2704012 VR2704020

750 750 1250 1250 2000 2000

1200 2000 1200 2000 1200 2000

16 16 25 25 40 40

q a f

Also tested per IEC 56 These values apply with circuit breaker in or out of enclosure. Close and Latch Rating (Momentary) Amperes rms = 2.7 k (Rated Short Circuit Current)

Breaker Identication
36.00
(914) Rear Aisle (114) (203)

4.50

27.00
(686) (508)

(114) (203)

4.50

8.00

20.00

8.00

VR
Top Breaker Below Bottom Circuit Breaker Above (Conduit Area)

27

025

12
Continuous Current Rating kA Rating Voltage Rating Circuit Breaker Type

3.50
(89)

(229)

9.00

53.30

(1354) 1.00 (25) (102)

11.00
(279)

4.00

28.00
(711)

(102)

4.00

Top Breaker Above Bottom Circuit Breaker Below (Conduit Area)

Weight (Approximate)
Section (less circuit breaker) 2600 lbs. (1179 kgs.) 600 lbs. (272 kgs.) 630 lbs. (286 kgs.)

110.50
(2807) (6) .75 Dia. Mounting Holes Recommended 4.00 Mounting Channels (3) Places (By Customer)

1200 A circuit breaker 2000 A circuit breaker

54.70
(1389) (203)

8.00

Control Conduit Area (Bottom)

1.00 2.00
(51) (25) Door

1.75
(203)

8.00

(44)

(1829) Front Aisle (1626) (Minimum)

72.00 (38)

1.50 2.50
(64)

34.20
(869) (914)

(23)

.90

(561)

2.00

64.00

(23)

.90

36.00
NOT FOR CONSTRUCTION (64) Control Conduit Area (Top)

2.50

Typical Indoor 1200/2000 A Floor Plan


Dimensions are in inches (millimeters).

Square D Company 330 Weakley Road Smyrna, TN 37167 615-459-5026 1-888 Square D (1-888-778-2733) www.squared.com

Catalog No. 6055CT9901 January 2000