Vous êtes sur la page 1sur 13

Air Conditioning

Technical Data
Wall mounted unit

EEDEN14-100

FTXZ-N

Indoor Unit FTXZ-N

TABLE OF CONTENTS FTXZ-N

1 2

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 4

3 4 5 6 7

Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8


Wiring Diagrams - Single Phase
.................................... 8

Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Sound Pressure Spectrum - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Sound Pressure Spectrum - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Split - Sky Air FTXZ-N

Indoor Unit FTXZ-N

1
ket tSi n uU - o mr tN o - i lo Z l dl X pnaT W IFS

Features
Unique combination of humidification, dehumidification, ventilation, air purification and heating & cooling in 1 system Enhanced comfort thanks to 2- area intelligent eye, improved airflow pattern and user friendly control No need to clean filters manually Reddot design award winner 2013 Online controller (optional): control your indoor unit from any location via smartphone, laptop, pc, tablet or touch screen

Econo mode

2 area Energy saving Comfort mode Powerful mode Auto coolingintelligent eye during standby heating mode changeover

Whisper quiet

Indoor unit Outdoor unit silent operation silent operation

Comfortable sleeping mode

3-D air flow

Vertical auto Horizontal auto Auto fan speed swing swing

Fan speed steps

Ururu Sarara Flash Streamer humidification dehumidificatio n

Titanium apatite 24 hour timer Infrared remote control photocatalytic air purification filter

Auto-restart

Self diagnosis

Split - Sky Air FTXZ-N

Indoor Unit FTXZ-N

Specifications
FTXZ25N FTXZ35N FTXZ50N

2-1 Technical Specifications


Power input Casing Dimensions Cooling Heating Colour Unit Packed unit Weight Heat exchanger Unit Packed unit Rows Fin pitch Stages Tube type Fin Fan Type Air flow rate Cooling High Nom. Low Silent operati on Heating High Nom. Low Silent operati on Fan motor Model Speed Steps Cooling High/ rpm Mediu m/Low/ Silent operati on rpm Heating High/ Mediu m/Low/ Silent operati on Sound power level Sound pressure level Cooling Heating Cooling Heating High High High/Nom./Low/ Silent operation Super high/High/ Nom./Low/Silent operation OD OD dBA dBA dBA dBA m/min cfm m/min cfm m/min cfm m/min cfm m/min cfm m/min cfm m/min cfm m/min cfm Type Quantity Quantity mm Height/Width/ Depth Height/Width/ Depth mm mm kg kg Nom. Nom. kW kW

0.030 0.030 White 295/798/372 434/865/361 15 19 4 (4) / 2 (5) 4 (4) / 6.35 (5) 14 (4) / 12 (4) / 10 (5) / 8 (5) Hi-XA (4) (front) / Hi-XB (6.35) (back) tube Multi slit fin Cross flow fan 10.7 379 7.5 265 5.3 188 4.0 141 11.7 415 8.6 303 6.7 236 4.8 168 MM12E06P12V 5 + silent, + auto 1,020/830/660/540 1,110/890/680/540 1,310/950/760/600 13.3 469 9.2 324 6.9 245 12.1 428 8.4 295 5.6 197 15.0 545 9.2 326 6.6 232 4.6 164 14.4 517 10.7 378 7.7 274 5.9 210

3
2

1,080/900/760/600

1,190/940/780/600

1,270/1,040/840/700

54 56 38/33/26/19 -/39/35/28/19

57 57 42/35/27/19 -/42/36/29/19

60 59 47/38/30/23 -/44/38/31/24

Piping connections

Liquid Gas Heat insulation

6.35 9.5 Both liquid and gas pipes Microcomputer control Right, Left, Horizontal, Downward

Temperature control Air direction control Air filter Type

Auto cleaning filter

Split - Sky Air FTXZ-N

Indoor Unit FTXZ-N

Specifications

Standard Accessories : Mounting plate; Quantity : 1; Standard Accessories : Indoor unit fixing screws; Quantity : 3; Standard Accessories : Remote control holder; Quantity : 1; Standard Accessories : Dry batteries; Quantity : 2; Standard Accessories : Wireless remote control; Quantity : 1; Standard Accessories : Photocatalytic air purifying and deodorising filter; Quantity : 1;

2-2 Electrical Specifications


Power supply Name Phase Frequency Voltage Current Wiring connections 50Hz Notes (1) 220V (2) 230V (3) 240V (4) Front of heat exchanger (5) Back of heat exchanger Nominal running Cooling current (RLA) - 50Hz Heating For power supply Remark Hz V A A

FTXZ25N

FTXZ35N

FTXZ50N

V1 1~ 50 220-240 0.14 (1) / 0.14 (2) / 0.13 (3) 0.14 (1) / 0.14 (2) / 0.13 (3) 3 for power supply, 4 for interunit wiring (Earth wire included)

Split - Sky Air FTXZ-N

Indoor Unit FTXZ-N

3
3-1

Options
Options

3
3

Split - Sky Air FTXZ-N

Indoor Unit FTXZ-N

4
4-1

Dimensional drawings
Dimensional Drawings

Split - Sky Air FTXZ-N

Indoor Unit FTXZ-N

5
5-1

Piping diagrams
Piping Diagrams

3
5

Split - Sky Air FTXZ-N

Indoor Unit FTXZ-N

6
6-1

Wiring diagrams
Wiring Diagrams - Single Phase

Split - Sky Air FTXZ-N

Indoor Unit FTXZ-N

7
7-1

Sound data
Sound Pressure Spectrum - Cooling

3
7

Split - Sky Air FTXZ-N

Indoor Unit FTXZ-N

7
7-2

Sound data
Sound Pressure Spectrum - Heating

10

Split - Sky Air FTXZ-N

These products are not within the scope of the Eurovent certification program

The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

BARCODE

Daikin products are distributed by:

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

EEDEN14-100 10/13 Copyright Daikin The present publication supersedes EEDEN13-100