Vous êtes sur la page 1sur 3

Page 1 of 3

12/04/2013
12:08:08 PM
D:\MK\MK 2013\J OBS\Tilal Complex\AB01
Column: Mark=COL Section=UB400X400X198 Grade=S355
D = 400 mm Root rad. = 0 mm fyf = 355 N/mm2
B = 450 mm Area = 2.5200E+04 fyw = 355 N/mm2
Tf = 20.0 mm Zx = 3640800 fu = 490 N/mm2
Tw = 20.0 mm Sx = 4068000
]py . . . . . . . . . . . . . . 355 N/mm2
]Us . . . . . . . . . . . . . . 490 N/mm2
]Ke . . . . . . . . . . . . . . 1.10
]Av . . . . . . . . . . . . . . 8000 mm2
]py . . . . . . . . . . . . . . 355 N/mm2
]py . . . . . . . . . . . . . . 355 N/mm2
]Us . . . . . . . . . . . . . . 490 N/mm2
]Ke . . . . . . . . . . . . . . 1.10
]Aeff . . . . . . . . . . . . . 2.5200E+04 mm2
.Section shear capacity . . . . . 1704.0 kN Note 2
.Section tension capacity . . . . 8946.0 kN
.Section compression capacity . . 8946.0 kN BS5950 4.7.4
Base plate:
450x450x32 Gr./fy/fu=S355/355/490N/mm2
Welds:
8 FW/440N/mm2 all around column.
CONNECTION: AB01 - Base Plate
Column: COL UB400X400X198 Gr.S355
Base plate: 450x32x450 Gr.S355 - Weld: 8 FW/440
HD Bolts: 4 x M24 4.6/N - 750 embedment
Foundation: 450 x 800 x 975 deep - 40 thick grout pad
225 225
7575
225
225
75
75
Page 2 of 3
12/04/2013
12:08:08 PM
D:\MK\MK 2013\J OBS\Tilal Complex\AB01
Bolts:
4 x M24 4.6/N anchor bolts.
Bolt hole dia. . . . . . . . . . 30 mm
No. bolt rows = 2
No. bolt cols. = 2
Spacing of outer bolts, sg = 150 in XX direction.
Spacing of outer bolts, sp = 150 in YY direction.
Embedment length = 750, no hook.
Shear capacity of bolts considered.
No shear key.
Foundation:
Foundation strength, fcu . . . . 40.0 N/mm2
Grout thickness . . . . . . . . . 40 mm
Rectangular, D . . . . . . . . . 450 mm
B . . . . . . . . . 800 mm
Min. bolt edge distance . . . . . 150 mm
Depth . . . . . . . . . . . . . . 975 mm
Coefficient of friction . . . . . 0.40
]py . . . . . . . . . . . . . . 355 N/mm2
]Us . . . . . . . . . . . . . . 490 N/mm2
]Ke . . . . . . . . . . . . . . 1.10
]py . . . . . . . . . . . . . . 355 N/mm2
]Us . . . . . . . . . . . . . . 490 N/mm2
]Ke . . . . . . . . . . . . . . 1.10
]Av . . . . . . . . . . . . . . 8000 mm2
]py . . . . . . . . . . . . . . 355 N/mm2
]py . . . . . . . . . . . . . . 355 N/mm2
]Us . . . . . . . . . . . . . . 490 N/mm2
]Ke . . . . . . . . . . . . . . 1.10
]Aeff . . . . . . . . . . . . . 2.5200E+04 mm2
MINIMUM ACTION CHECK
(Minima are based on section capacity, not member capacity.)
Specified minimum design actions:
Shear 40.0 kN
Tension 0% of Ns ( 8946.0) = 0.0 kN
Compression 0% of Nc ( 8946.0) = 0.0 kN
NOTE: Input design actions are not automatically increased if they are less than
the specified minimum actions. Minimum actions may be set in any load case.
This check warns if any design action is less than the specified minimum
for all load cases.
WARNING: Design shear force is less than specified minimum.
INPUT DESIGN ACTIONS
Axial, N . . . . . . . . . . . . -1626.0 kN (comp.)
Shear, Vx . . . . . . . . . . . . 0.0 kN
Shear, Vy . . . . . . . . . . . . 0.0 kN
Using ASI 2011 model...
Ref. 56: Design Guide 7 - Pinned Base Plate Connections for Columns (DG7)
T.J. Hogan - ASI - 2011
DESIGN CAPACITY CHECKS...
Utilization ratio
Design action ]
Design capacity ] ] Reference
] ] ] ==============
NOTE: Capacity of section is not checked.
COMPRESSION ANALYSIS
CHECK 1 - Bearing on Concrete:
Base plate area, A1 . . . . . . . 2.0250E+05 mm2
Geometrically similar area, A2 . 2.0250E+05 mm2
Concrete confinement ratio . . . 1.00 ACI318 10.17.1
Design bearing stress . . . . . . 24.0 N/mm2
Concrete foundation capacity, Nc . . . . . 4860.0 ` Pc = 1626.0 33% Pass ACI318 10.17.1
CHECK 2 - Steel Base Plate Bending:
For I section...
]a1 . . . . . . . . . . . . . . 35 mm
]a2 . . . . . . . . . . . . . . 45 mm
Page 3 of 3
12/04/2013
12:08:08 PM
D:\MK\MK 2013\J OBS\Tilal Complex\AB01
]a4 . . . . . . . . . . . . . . 106 mm
]a5 . . . . . . . . . . . . . . 850 mm
]k . . . . . . . . . . . . . . . 2.12
]X . . . . . . . . . . . . . . . 0.38
]lambda . . . . . . . . . . . . 0.726
]alpha0 . . . . . . . . . . . . 76.96
Modified Thornton plate capacity, Ns . . . 4971.3 ` Pc = 1626.0 33% Pass ASI DG7 p.32
Min. thickness, tmin . . . . . . 25 mm SCM13 p.14-6
CHECK 3 - Weld at Column Base:
Total weld length . . . . . . . . 2480 mm
NOTE: X and Y shear forces are resisted only by weld elements aligned in the
same direction as the shear force.
]Throat . . . . . . . . . . . . 5.7 mm
]Weld metal Ue . . . . . . . . . 440 N/mm2
]pw . . . . . . . . . . . . . . 220 N/mm2
]Weld metal capacity . . . . . . 1.245 kN/mm
Column weld capacity . . . . . . . . . . . 1.245 ` vres = 0.000 0% Pass
NOTES:
2. Shear yield capacity ignoring slenderness.
CRITICAL LIMIT STATE . . . Concrete foundation capacity, Nc
UTILIZATION RATIO . . . . 33%
CAPACITY RATIO . . . . . . 2.989 Pass