Filac 3000 OEM Thermometry Technology for Integration into Multi-Parameter Devices

Market Leading Technology


Choosing the Filac 3000 OEM thermometry option for your multi-parameter device, means that you will have access to the resources necessary to successfully satisfy the demands of the market. Our Filac 3000 OEM thermometry offerings are RoHS compliant, meet IPC 610 standards, and are manufactured in FDA regulated / ISO 13485 registered facilities.

Easy Intergration
The Filac 3000 OEM thermometry offerings have been designed specifically for OEM integration. Our developers kits contain all of the information needed to facilitate integration of the Filac 3000 thermometer technology into your multi-parameter device. Developers also will be provided other necessary tools including mechanical models, drawings, communication protocols, interface documentation and component samples.

Market Acceptance
The Filac 3000 thermometers and probes are known for reliability, durability and accuracy. Many companies integrate our technology in their multi-parameter units

Infection Control
The color coded Filac 3000 isolation chambers are also available for integration to provide a simple, yet effective, means of preventing cross-contamination between oral and rectal probes. The Filac 3000 OEM component auto senses an attached probe and adjusts the measurement technique accordingly for an oral/axillary or rectal reading.

Technical Support
Your satisfaction and the success of your multi-parameter device occupy the core of our focus. Should you have any customer support inquiries related to our components or development kits, our experienced team of engineers and sales associates will be at your service for technical and ordering support.

Quick Predictive Measurement Technology

PRODUCT SPECIFICATIONS

ACCURACY
Quick Mode: (Oral) +/- 0.3O C (+/-0.6O F) Standard Mode: (Axillary/Rectal) +/- 0.1O C (+/-0.2O F) Direct Mode: +/- 0.1O C (+/-0.2O F)

MEASUREMENT RESPONSE TIME


Quick Mode: 3-5 seconds (Oral) Standard Mode: 6-10 seconds (Oral) Auxillary: 8-12 seconds Rectal: 10-14 seconds Direct Mode: 60-120 seconds

Order Information
Code 500062 500026 500027 500028 500036 500037 500038 502000 500099 Description Ship Case Filac 3000 OEM PCB 80 Filac 3000 Oral Probe 4ft 1 Filac 3000 Oral Probe 9ft 1 Filac 3000 Oral Isolation Chamber 1 Filac 3000 Rectal Probe 4ft 1 Filac 3000 Rectal Probe 9ft 1 Filac 3000 Rectal Isolation Chamber 1 Filac 3000 Probe Covers 2000 Each/Case Filac 3000 Calibration Plug 1

AMBIENT OPERATING RANGE


10O C - 40O C (50OF - 104OF) at 10%-95% RH

TEMPERATURE RANGE
30O C - 43.0O C (86.0OF - 109OF)

STORAGE TEMPERATURE RANGE


-25O C - 55O C (-13OF - 131OF) at 95% RH (non-condensing)

Voltage Requirements
5-6 volts

ISOLATION CHAMBER

For additional information contact Customer Service at 1-800-962-9888