PLATE HEAT EXCHANGER

SOLTEQ

MODEL: HE 200
DESCRIPTION
Hot Water Circuit:
A stainless steel hot water tank heated by a suitably
sized electric heater serves as the hot water source. The
hot water temperature is controlled by a temperature
controller up to 70C. A centrifugal pump circulates the
hot water through the circuit. A flowmeter is provided for
measuring the hot water flowrate. Two temperature
gauges are provided for the inlet and outlet temperature.
All process pipings are of stainless steel type and ap-
propriate insulation is applied to minimize heat loss.
Cold Water Circuit:
A stainless steel cold water tank acts as the source of
cold water to be heated and is pumped through the cold
water
HIS Plate Heat Exchanger (Model: HE 200) has been designed to introduce students on the principles of
a plate exchanger. The equipment consists of mainly a stainless steel plate heat exchanger with cold and
hot water circulation systems. Instrumentations for heat exchanger studies are provided for collecting all
necessary process data such as liquid flowrates and temperatures. Students will be able to calculate heat transfer
coefficients, heat exchanger efficiencies, LMTD, etc., based on the experimental results.
T
Equipment for Engineering Education & Research
S
O
L
T
E
Q
SOLTEQ

circuit and discharge into drain. A flowmeter is provided


for measuring the cold water flowrate. Two temperature
gauges are provided for the inlet and outlet temperature.
All process pipings are of stainless steel type.
EXPERIMENTAL CAPABILITIES
Determination of heat load, heat loss, LMTD and
energy balance calculation
Calculation of overall heat transfer coefficient
Study of co-current and counter-current flow
Temperature profile plot in the exchanger
Relationships between flow rates and temperature
difference on the heat transfer rate
SPECIFICATIONS
Rig:
Epoxy coated skid mounted plateform with lockable
castor wheels.
Plate Heat Exchanger:
Heat Transfer Surface Area : 0.96 m
2
Total No. of Plates : 30
Hot Water : 20 LPM, 65 C
Cold Water : 20 LPM, 30 C
OperatingTemperature : 65 C
Nozzles : SS AISI 316
Plates : SS AISI 316, 0.50mm
Gaskets : Rubber, NBR-Clip-on
Connections : Straight pipe thread 36mm
ISO R1-1/4
Dimension (W x D x H) : 250mm x 180mm x 490mm
Hot Water System:
Tank : 100-L, stainless steel
Level control : float type control valve
Circulation pump : centrifugal type, 20 LPM, dry run
protected by level switch
Heating system : 34 kW immersion type heater
protected by temperature control
and level switch
Cold Water System:
Tank : 100-L, stainless steel
Level control : float type control valve
Circulation pump : centrifugal type, 20 LPM, dry run
protected by level switch
Instrumentations:
Instruments for the measurements of temperature and
flow rate.
OPTIONAL ITEMS
- EI
DIGITAL INSTRUMENTATIONS
i) 2 Units of Digital Indicators
ii) 2 units of electronic flowmeter
iii) 4 units of pt100 RTD sensors c/w transmitters
- DAS
SOLDAS DATA ACQUISITION SYSTEM
i) A PC with Pentium processor
ii) A signal conditioning unit
iii) A stand alone data acquisition modules
iv) A Windows based software
Data Logging
Signal Analysis
Process Control
Real-Time Display
Tabulated Results
Graph of Experimental Results
- CAL
SOLCAL COMPUTER AIDED LEARNING SOFTWARE
i) Interactive multimedia features
ii) Graphical simulation
iii) Experiment results samples
iv) Full experiment manuals
UTILITIES REQUIREMENT
Electricity : 415VAC/3-Phase/50 Hz/60A
Water : Laboratory mains supply
Drainage
OVERALL DIMENSIONS
Height : 2.00 m
Width : 2.00 m
Depth : 1.22 m
MANUAL
The unit is supplied with Operating and Experiment
manuals in English.
Equipment for Engineering Education & Research
S
O
L
T
E
Q
TYPICAL EXPERIMENT RESULTS
PLATE HEAT EXCHANGER EFFICIENCY AT VARIABLE HOT WATER FLOW RATE
(Hot Water Temperature = 50
0
C)
93.50
94.00
94.50
95.00
95.50
96.00
96.50
97.00
97.50
98.00
98.50
99.00
0.00 5.00 10.00 15.00 20.00 25.00
COLD WATER FLOW RATE (LPM)
E
F
F
I
C
I
E
N
C
Y

(
%
)
F1 =15 LPM
F1 =10 LPM
SOLTEQ

Equipment for Engineering Education & Research


PLATE HEAT EXCHANGER EFFICIENCY AT VARIABLE HOT WATER TEMPERATURE
(Hot Water Fl ow Rat e, F1 = 10 LPM)
84.00
86.00
88.00
90.00
92.00
94.00
96.00
98.00
100.00
0.00 5.00 10.00 15.00 20.00 25.00
COLD WATER FLOWRATE (LPM)
E
F
F
I
C
I
E
N
C
Y

(
%
)
T1 =65 C
T1 =50 C
Our range of teaching equipment can be complemented with our
SOLDAS and SOLCAL software.
SOFTWARE &E - LEARNING
SOLDAS

- Supervisory Control & Data Acquisition
- Data Logging
- Signal Analysis
- Process Control
- Real-Time Display
- Tabulated Results
- Graph of Experimental Results
SOLCAL

- Computer Aided Learning
- Multimedia Features
- Interactive
- Graphic Simulation
- Experiment Result Samples
- Full Experiment Manuals
SOLTEQ

Contact us for a catalog CD


SOLUTION ENGINEERING SDN. BHD.
(Co. No. 174876-M)
Sales Office :
No.3, J alan TPK 2/4, Taman Perindustrian Kinrara,
47100 Puchong, Selangor Darul Ehsan, Malaysia.
Tel. No. : +(603) 80758000
Fax. No.: +(603) 80755784
R&D Office :
G-2A, Incubator 3, Technology Park Malaysia,
Bukit Jalil, 57000 Kuala Lumpur, Malaysia.
Tel. No. : +(603) 8996 0023
Email : solution@solution.com.my
Web site : http//www.solution.com.my/
AGENT:
Equipment for Engineering Education & Research
BUATAN MALAYSIA
MSC- Status
Company

Vous aimerez peut-être aussi