ShortCircuitAnalysis&ProtectiveDevicesCoordination

COURSEOVERVIEW:
A safe and reliable Power System must be designed with its entire component able to withstand the onerous Short Circuit Current that can occur in their respectivepointofinstallation.Themagnitudeofthe a direct proportion to the product of the square of the current and the fault duration. Hence, electrical protection plays a very important role in the consideration, as it dictates the time persistence of theshortcircuitcurrent. Alternatively, the magnitude of short circuit current that can flow to a part of a system can be limited in variouswaysaswillbediscussedinthismodule. There are, however, advantages and disadvantages of high short circuit capability of a system. It is a disadvantage to a system because comparatively large equipment is required for higher fault current. On the other hand, a strong power supply (high fault current) has the greater advantages of supporting the starting requirement of large motors, and minimizestheeffectofpowersystemharmonics.
Protection of the Power System requires understanding of system faults and their detection, as well as their reliable safe isolation from the system. This course presents comprehensive and systematic

COURSELANGUAGE:
The Presentation, supplied documents, and work shop exercises of the course are in English; however, based on the trainees desires, use of bilingual (English and Arabic) for oral explanation is

damaging effect of these short circuit currents is available.

WHOSHOULDATTEND?
The course is designed to Electrical Maintenance Engineers and Highly Qualified Technicians those working in Protection Department for Electrical Power Generation, Transmission and Distribution. Also, Operation Engineers are recommended to attendthecourse.

COURSEOBJECTIVES:
By the end of this course, the participants will be ableto:

CalculateSymmetrical&UnsymmetricalFaults The perunit system and analytical circuit based systemsforfaults. Calculate the Value of an Impedance to limit shortCircuitLevel. Understanding the Practical Consideration of ProtectionDevicesandCoordination

techniques to calculate industrial power

KnowingthefaultreasonsinElectricalNetworks an

andtheireffectontheelectricalquantities. Understanding main concepts of Protection EquipmentanditsnecessityinelectricalSystem. How to make relay coordination for main and backupprotectionrelaysonelectricalnetwork. How to find the cause of relay operation and verifyifitiscorrect,fallsormaloperation. abnormaloperatingconditions.

descriptions of the concepts and principles of application and operation of protection schemes applied for various power system elements. Many utilities need this course that studies the relay characteristics during faults and weakprotectionpointsinelectricalpowersystems. In addition, the course enforces the concepts by presenting case studies occurred on the system. The course will be valuable to engineers and technicians just entering the system protection field and those seeking a better understanding of the new stateoftheart of protectiverelaying.

How to protect the power system due to

ShortCircuitAnalysis&ProtectiveDevicesCoordination COURSEOUTLINES:
Module(1)PSSourcesandConfigurations 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 2.1 2.2 2.3 2.4 2.5 2.6 2.7 Module(3)SymmetricalComponentsandFaultAnalysis 3.1 TransformationofPhaseQuantitiestoSequence Quantities 3.2 LineandCableSequenceImpedances 3.3 3.4 3.5 Module(4)FundamentalsofShortCircuitCurrents 4.1 4.2 4.3 4.4 4.5 4.6 4.7 Module(5)CalculationofShortCircuitCurrent 5.1 5.2 5.3 5.4 5.5 5.6 5.7 DerivationofFormulas EstablishmentofImpedanceDiagram ThreePhaseShortCircuitCurrent LinetoGroundShortCircuitCurrent LinetoLineShortCircuitCurrent AsymmetricalShortCircuitCurrent Exercises ShortCircuitCurrentsandtheirEffects SourcesofShortCircuitCurrents BehaviorofShortCircuitCurrentsContributedby Equipments ImpedanceofStaticEquipmentandDevices RotatingMachinesImpedance ComponentsoftheTotalShortCircuitCurrent PhaseFaults RotatingMachineSequenceNetworks SequenceFilters StudyCase ElectricalEngineeringBasicConcepts VoltageLevels OneLineandThreeLineDiagram GenerationSystemLayout TransmissionLayout DistributionLayout SubstationLayout CaseStudy SinglePhaseSystem ThreePhaseSystem TransformerRepresentationinthePerUnitSystem SystemAnalysisinthePerUnitSystem TransformerswithOffNominalTurnsRatios Summary CaseStudy Module(6)ComputerProgramsforSCFaultsCalculation 6.1 6.2 6.3 6.4 7.1 7.2 7.3 7.4 PowerSystemRepresentation BestSoftwareforShortCircuitCalculation? EMTPProgram ATPProgram LowVoltageMotorStarters LowVoltageFuses LowVoltageAirCircuitBreakers MoldedcaseCircuitBreakers

Module(7)SelectionofSCProtectiveDevices&Coordination

Module(2)ThePerUnitSystem

7.5HighVoltageMotorStarters/Fuses 7.6PowerCircuitBreakers 7.7AutoRecloser 7.8Sectionlizer 7.9ProtectiveRelays 7.10TimeDelayoverCurrentRelaysSettings 7.11InstantaneousoverCurrentRelaysSetting 7.12EarthFaultRelaysSetting Module(8)Earthing&SizinganImpedancetoLimitFault 8.1 Introduction 8.2SelectionofGroundingMethod 8.3SelectionofGroundingSystem 8.4 UnderstandingGroundResistance 8.5 GroundResistanceValues 8.6 EffectofTypeofEarthingonFaultCurrentLevel Module(9)CaseStudy(1) DesignofDistributionBoardandSelectingaCableto withstandFaultCurrent 9.1 ResidentialLoadDistributionBoardDesign 9.2 LightingLoads 9.3ShortCircuitCurrent 9.4CBCapacity 9.5CablesCrossSection 9.6Applications 9.7MainCB 9.8PhaseBalance 9.9DesignofMotorDistributionBoard 9.10Load/StartingCurrent 9.11OutageFeeders 9.12CablesSelectionDesign 9.13CBSelectionDesign Module(10)CaseStudy(2) CoordinationStudyofMV&LVIntegratedPowerSystem

CourseSummary&Conclusion

ShortCircuitAnalysis&ProtectiveDevicesCoordination

About Instructor

COURSEFEE
The amount of 2500 USD will be charged for the course fee. Send (3) delegates and get a 10% discount on the thirdparticipant.

Prof.ElsayedShehabEldin
ElectricalMachines&PowerEngineering, HelwanUniversity,Egypt

Prof. Shehab Eldin is a senior consultant with many University,England,1988inElectricalEngineering.Now he is with Faculty of Engineering, Helwan University, Cairo,Egypt. He is expert in training and consultation fields, and has been doing a lot of activities for more than twenty years in Middle East and North of Africa Region. He is specialized in Electrical Switchgears and Protection & Relays.

PAYMENTMETHOD
Note that full payment must be made prior to the event. admitted to the event. All payments should be to APEX Account: HSBCBankMiddleEastlimited, JebelAliBranch,Dubai,UAE A/C:035626472101 SwiftCode:BBMEAEAD

companies who obtained his PhD from Cambridge A confirmation letter will be sent upon your registration.

Only those delegates who have paid in full will be

CANCELLATION

He has lectured extensively in the field of Powerasubstitutedelegate.

If you are unable to attend the course you may send

System Analysis, Fault Analysis, Protection and Switchgears, LV, MV and HV Modern Circuit Breakers, Cancellation should be made 20 days prior to the course Operation,MaintenanceandTestingofProtection. He has more than 50 published papers and some educational books in the Electrical Power Engineering area.HereceivedmanyawardsfromEnglandandEgypt duringhisAcademicandPracticalExperience. His approach is at the cutting edge of development of Electrical System Networks. His unique perspectives and methodologies are based on the assumption that inventiveness of their systems and staff in line with theircustomerschangingexpectations.
requiredtopaythecoursefeeinfullamount.

conduction. Failure to cancel within 10 days will be

REGISTRATIONFORM
Name(Mr./Ms.)________________________________ Position_______________________________________ Email_________________________________________ Department____________________________________ Company______________________________________ Address_______________________________________ TelephoneNo.__________________________________ FaxNo.________________________________________

Country___________________ZipCode_____________ organizations must find ways of tapping the

He had a good experience in Technical Training in Electrical Field as a General and in Protection Field as

CONTACTDETAILS
+971 4 3622021 / +971 4 4458567 00971 4 367 8636

his specialty, he gave more than 50 Industrial condensed courses for Engineers, and Technicians in Middle East Companies related to Electrical Faults Analysis,PowerSystemProtections&Relays,LoadFlow Analysis & Short Circuit Calculation, ART & Science of ProtectionRelaysandElectricalSwitchgearsHV,MV,LV.

info@apex-dubai.com www.apex-dubai.com