Product Version N 1
No. Of Lamp 3
1 2 3 4 = = = = 1 Lamp 2 Lamp 3 Lamp 4 Lamp
Lamp Wattage 3 6
Ballast Type 1 1
MS white painted CAT III reector (L1) Specular nish Al. CAT III reector (L1) Specular nish Al. CAT II reector (L2) Non Category Louvre Polycarbonate Louvre
To Choose from Commercial range mirror optic AS series 36W with multiple variables. Specication Variables Non Category louvres, Normal EM Ballast Non Category louvres, 6.0W EM Ballast L1 Category Louvres, 6.0W EM Ballast L2 Category louvres, HF individual Ballast < 33% LHCCC1336126 L2 Category louvres, HF individual Ballast < 10% LHCCC1336128 Ordering Code LHCCN1336111 LHCCN1336113 LHCCB1336113
CFL Lamps 09 = 9W CFL 11 =11W CFL 13 = 13W CFL 18 = 18W CFL/FPL/FTL 26 = 26W CFL 36 = 36W FPL/FTL FTL / T5 Lamps 02 = 20W FTL 04 = 40W FTL 08 = 8W T5 FTL 14 = 14W T5 FTL 21 = 21W T5 FTL 28 = 28W T5 FTL 54 = 54W T5 FTL HID Lamps 70 = 70W SV/MH 80 = 80W MV 12 = 125W MV 15 = 150W SV/MH 25 = 250W MV/SV/MH 40 = 400W MV/SV/MH 60 = 600W SV 10 = 1000W SV/MH
FTL/ FPL OCB 07 = 230V, 18/20W FTL/FPL OCB 09 = 230V, 36/40W FTL/FPL OCB 11 = 240V, 36/40W FTL/FPL OCB 15 = 240V, 18/20W FTL/FPL OCB CFL OCB 17 = 7/9/11W CFL OCB 18 = 13W CFL OCB 20 = 18W CFL OCB 21 = 26W CFL OCB Electronic Ballasts 26 = 1X36/40W FTL EB THD<33% 27 = 2X36/40W FTL EB THD<33% 32 = 1X28W T5 FTL EB THD<33% 33 = 2X28W T5 FTL EB THD<33% 28 = 1X36/40W FTL DB THD 10% 29 = 2X36/40W FTL DB THD<10% 50 = 1X28W T5 FTL DB THD<10% 51 = 2X28W T5 FTL DB THD<10%
Guide to Symbols
Accessories
A high intensity discharge lamp generally shows peculiar negative resistance characteristic, while striking the lamp it exhibits a very high impedance thus drawing no current. As starter circuit ignites, the arc establishes the current path between two electrodes. The impedance reduces fast and current rises. Unless this inrush current is controlled, lamp arc tube may lead to active failure. Ballast normally ensures that this current supplied to lamp is limited and established to desired level. Often therefore it is called current limiting device. Ballast popular in India are of two types : a) Electromagnetic b) Electronic. While electromagnetic ballast offer low power factor and compensating circuits are needed to improve it, electronic ballast invariably offer better power factor and are ideal for reliable ignition especially even at low voltage areas. Electromagnetic Ballast Selection of proper ballast not only ensures prolonging maintenance cycle but also helps optimization of lamp performance. A ballast like most electrical components, generates heat due to its ohmic resistance and magnetic losses. It is the temperature of the choke coil during operation that is important. The max permissible coil temperature tw is required to be marked on ballast. A tw value of 120C is achieved with coil insulating class E. Under the specied conditions average ballast life of ten years may be expected for a continuous operations at coil temperature specied in twC. However a 10C temperature rise above twC value will halve its expected life. A 20C above tw value, a ballast life of not more than 2.5 years of continuous operation be expected. If ballast has no tw marking, a maximum of 105C is assumed for the coil temperature. (Class A insulation tw is 105C, Class E insulation tw is 120C and for Class F insulation tw is 150C.) Another value to be marked on any ballast is the coil temp rise Dt. This is differentiation between the absolute coil temp and ambient temp in standard condition. (This is measured as specied in IEC 920 (EN 60920). Common values for Dt are from 50C to 70C in steps of 5C). A ballast selected therefore marked with say tw 120 and Dt 70 will have specied 10 years average life in continuous operation at standard condition at an ambient temperature of 120C-70C = 50C. If ambient around ballast is higher, shorter ballast life will result unless adequate air circulation in cooling is applied within gear compartment. The ambient temperature of 50C indicated is not a room temperature or environmental temperature but is a temperature of the microenvironment of the ballast. Ballast in luminaire or control gear, the air temperature around it is higher than outside ambient temperature. Therefore higher temperature has to be added to coil temperature rise Dt to nd absolute coil temperature tc = t2 + Dt. Ballast losses published are maximum cold values. Published Dt & tw ratings are for standard conditions and shall vary differently in different enclosures if measured. For perennial low voltage areas
ballast lower tappings rating can be used. A caution is however needed if voltage shows tendancy to rise beyond the rated voltage in late night hours, if used in lower tapping; premature failure of ballast may be inevitable. Electronic Ballast To over come the heat, ignition at low voltage and circuit compensation problems, it is prudent to select more rened yet energy saving ballast commonly available for uorescent and selectively available for low wattage HID circuits. The vagaries of Indian mains supply across the country must protect the ballast from malfunction. Multiple types of ballasts are available in market. A guidance therefore is necessary for unsuspecting purchaser, following are few of the tips: Instant start EB is essentially cold start ballast and do inflict damage to lament of FTL if used in multi switching (>3 cycles/ day) installation. Lamp life is reduced. Rapid start EB is (pre-heat) warm start ballast and prolongs the life of FTL to its declared life and is ideal for multi switching installation. Circuit protection to be built-in are: In-rush current protection a must in Instant Start EB, while Rapid Start it is not warranted. Source aging protection will lead to safety of the ballast during aging of lamp. Over voltage auto shut off circuit. It will ensure that the circuit shuts off in case of mains voltage over shoots the specied designed voltage (300 - 305V) Preheat current in warm start EB should be reduced to minimum once the lament temperature reaches 700K. Else the continuous pre-heat current leads to premature failure of lament. Published series in this catalogue of industrial and domestic electronic ballast conrm to relevant standards. Our digital ballast series are Active Power Factor Circuits (APFC) and are constant wattage output ballast for wide range of mains voltage variance (170-265V). The service life of our Digital ballast in standard condition is in excess of 35000 hours with failure rate of less than 2 for every 100 ballast installed in 3 phase 4 wire balanced circuit installations. Our complete range of electronic ballasts operate at >40 KHz and are immune to infra-red remote operations. These are designed for complete hum and icker free operations for your safety. Published data is as per specied test procedures laid in relevant BIS & IEC publications. These are measured in stand alone condition at 230V, 50Hz for domestic products and 240V, 50Hz for industrial products at perfect sinusoidal wave form. At actual working environment due to variance in mains supply wave form and frequency this publish data may show changes if THD and frequency level of the utility supply is not as per the norms. Note: All types of ballast especially HID and electronic, are exposed to premature failure if these are run with the lamps reaching its end of service life. It is advisable therefore to ensure that lamps/tubes are replaced at the end of its service life rather than awaiting lamp failure to occure.
Accessories
9
1131
Top View
852
1982
Ordering Code
LHGW02170B99 LHBW08170036 LHGW02115B99 LHBW08115036 LHGW02125B99 LHBW19125036
Lamp Type
1x70W SV/MH 1x150W SV/MH 1x250W SV/MH
Power Factor
>0.85 >0.85 >0.85
Ballast L Cap N R Y
Accessories
10
1681
1262
19
Ordering Code
LHGW02140B99 LHBW08140036 Ballast L Cap N R Y B lgn Lamp 30mtrs.
Lamp Type
1x400W SON/MH
Power Factor
>0.85
Accessories
11
Top View
17
2222 Front View
852
1862
901
Ordering Code
LHGW04170B99 LHBW08170036 LHGW04115B99 LHBW08115036 LHGW04125B99 LHBW19125036
Lamp Type
1x70W SON/MH 1x150W SON/MH 1x250W SON/MH
Power Factor
>0.85 >0.85 >0.85
Ballast L Cap N R Y
Accessories
12
1302
Ordering Code
LHGW03140B99 LHBW08140036
Lamp Type
1x400W SON/MH
Power Factor
>0.85
Ballast L Cap N R Y
Accessories
13
310
1602
Top View
1 7
1202
2822
Ordering Code
LHGW04225B99 LHBW19125036 LHGW04240B99 LHBW08140036 Lamp B N lgn
Lamp Type
2x250W SON/MH 2x400W SON/MH
Power Factor
>0.85 >0.85
Ballast L Cap R Y
30mtrs.
Accessories
14
CD
Dimension Details
W
Lamp Type
1x70W SON/MH 1x150W SON/MH
Length (L in mm)
1902 2102
Width (W in mm)
782 782
Height (H in mm)
652 652
CD (in mm)
1761 1941
Top View
L Front View
Ordering Code
LHGW41170D36 LHGW41115D36
Lamp Type
1x70W SON/MH 1x150W SON/MH
Power Factor
>0.85 >0.85
* for indore use only. Distance limit between CGU & Lamp - 5mtr. CGU
LAMP
MAINS
LAMP
Accessories
15
Nugget
Compact encapsulated in engineering plastic FR grade cover, electromagnetic copper wound integrated gear unit for reliable ignition of 70/150W HID SON/MH lamps for indoor use.
Specication
Cover made-up of heat resistant engg. plastic FR grade to prevent fi re Compact size encapsulated copper wound gear integrated with Short distance ignitor and power factor improvement capacitor Electrical grade steel and double insulated grade enamel wire ensures long and reliable operation Built in capacitor eliminates external wiring of compensation circuits Designed for only indoor/ shielded out door environments. Hazardous if used in exposed out door conditions Designated mains and lamp terminals for ease of direct wiring
161.8
Dimension Details
76.4
Lamp Type
1x70W SON/MH 1x150W SON/MH
Length (L in mm)
1762 1762
Width (W in mm)
812 812
Height (H in mm)
68.52 68.52
CD (in mm)
1621 1621
Top View
L~M
68.31
Ordering Code
LHGW42170D36 LHGW42115D36
Lamp Type
1x70W SON/MH 1x150W SON/MH
Power Factor
>0.85 >0.85
LAMP
Accessories
16
CD Top View
Dimension Details
Lamp Type
1x35W CDMT/MH 1x70W SON/MH 1x150W SON/MH 1x250W SON/MH NEW 1x400W SON/MH 1x125W HPMV 1x250W HPMV 1x400W HPMV
Length (L in mm)
1171 1121 1472 1472 1472 1472 1472 1472
Width (W in mm)
601 641 641 1022 1022 1022 1022 1022
Height (H in mm)
521 571 571 912 912 912 912 912
CD (in mm)
921 921 1281 134x80 134x80 134x80 134x80 134x80
L Front View
Connector
W Side View
5mtrs. Lamp
Ordering Code
LHBM01135036 LHBW08170036 LHBW08115036 LHBW19125036* LHBW08140036 LHBG08112036 LHBG08125036 LHBG08140036
Lamp Type
1x35W CDMT/MH 1x70W SON/MH 1x150W SON/MH 1x250W SON/MH NEW 1x400W SON/MH 1x125W HPMV 1x250W HPMV 1x400W HPMV
Power Factor
>0.45 >0.36 >0.41 >0.39 >0.43 >0.52 >0.53 >0.55
For HPSV/ MH lamp with impulse ignitor LHNM05000D99/ LHNW07000A99 Ballast L Cap N R Y B lgn Lamp 30mtrs.
For HPSV/ MH lamp with impulse ignitor LHNW17000B99 Ballast L Cap N B Lp N lgn Lamp 5mtrs.
Accessories
17
Electronic Ballast
Industrial electronic HID ballast suitable 35W/70W/150W ceramic Metal Halide lamp. for
Specication
Suitable for 220-240V/ 50Hz Ignition time <2 secs Crest Factor (CF) <1.70 Output Frequency >150Hz High power factor (PF) >0.98 Total Harmonic Distortion (THD) <10% IR radiation immune, hum free operation
Advantages:
W
CD
Optimal lamp control & operation Micro processor control & monitoring of operation status Comfortable operation Longer lamp life Push-fit type connector Low energy consumption with low heat generation Conforms to IEC 61547/ IEC 61000 Programmed APFC regulated high frequency ballast for multiple switching cycle
Dimension Details
Lamp Type
1x35W CMI 1x70W CMI 1x150W CMI
U-OUT=350V
LL
LAMP
Length (L in mm)
1102 1102 1652
Width (W in mm)
752 752 912
Height (H in mm)
331 331 391
CD (in mm)
961 961 157x74
LH
Top View
L Front View
Ordering Code
LHBI01135056 LHBI01170057 LHBI01115058
Lamp Type
1x35W CMI 1x70W CMI 1x150W CMI
Power Factor
>0.98 >0.98 >0.98
Wattloss (W)
8.0 12.0 18.0
Accessories
18
Copper Ballast
Industrial grade vaccum impregnated (VPIT) ballast designed to be operated at 220V-240V/ 50Hz mains supply. Also available in low loss (ACCURA) version.
Specication
Compact in size Designed for 240V/ 50Hz., AC supply Low loss silicon steel lamination Super enamelled copper wire Vaccum impregnated (VPIT) open construction Low watt loss (less than12W) Better heat dissipation Hum free operation Maximum winding temp. tw- 1200 C, Temp. rise., Dt- 700 C Long life Conforms to IS: 1534(Part1) of 1977
Dimension Details
CD Top View
Lamp Type
1x18/20W FTL/FP-L 1x36/40W FTL/FP-L 1x26W PL-C
Length (L in mm)
1372 1372 1372
Width (W in mm)
411 411 411
Height (H in mm)
331 331 331
CD (in mm)
1151 1151 1151
L Side View
Ballast L Cap N Lamp S For Single tube of 18/20/36/40W FTL with universal starter (FSU) Ballast L N Cap Lamp S Lamp S
Ordering Code
LHBF18002015 LHBF18004011 LHBC18026021
Lamp Type
1x18/20W FTL/FP-L 1x36/40W FTL/FP-L 1x26W PL-C
Wattloss (W)
12.0 12.0 12.0
Power Factor
>0.42 >0.52 >0.50
Accessories
19
861
tc Ballast Lamp
450.5
4 Pin
2 Pin
Advantages:
Compact in size, energy efcient and with universal mounting holes for easy replacement of electromagnetic ballast. Ideal for areas of low voltage pick-ups.
31
Ordering Code
4Pin CFL EB LHBC07113055 LHBC07118055* LHBC07126055 2Pin/4Pin CFL EB LHBC07113054 LHBC07118054
L N
Lamp Type
1x9/11/13W CFL 1x18W CFL 1x26W CFL 1x9/11/13W CFL 1x18W CFL
Wattloss (W)
2.0 2.0 3.0 2.0 2.5
Power Factor
>0.90 >0.90 >0.55 >0.55 >0.55
Lamp
Lamp 2Pin
Accessories
20
Industrial electronic ballast suitable for single or twin T12/ T10/ T8/ T5 linear uorescent lamps. In-built preheat start and cut-off circuits ensure enhanced lamp life with failure resistant ballast.
Suitable for 220-240V/ 50Hz Ignition time <2 secs Crest Factor (CF) <1.90 Output Frequency >40KHz High power factor (PF) >0.95 Total Harmonic Distortion (THD) <33% IR radiation immune, hum free operation Circuit designed for higher (300V) mains voltage & ageing protection
Advantages:
H
CD Top View
Longer lamp life Push-fi t type connector Striation free operation Low energy consumption with low heat generation Programmed warm start (pre-heat) circuit enables lamps for multiple switching cycles Conforms to EN 60928 & EN 60929
Dimension Details
Lamp Type
1x14W T5 FTL 2x14W T5 FTL 1x28W T5 FTL 2x28W T5 FTL 1x54W T5 FTL 1x36/40W FTL 2x36/40W FTL 2x18/20W FTL 1x24W FTL 2x24W FTL
L Side View
Length (L in mm)
265 305 305 305 305 305 305 305 265 305
Width (W in mm)
28 30 30 30 30 30 30 30 28 30
Height (H in mm)
24 28 28 28 28 28 28 28 24 28
CD (in mm)
2541 2961 2961 2961 2961 2961 2961 2961 2541 2961
L N E
Lamp
BALLAST
Ordering Code
LHBT01114031 LHBT01214040# LHBT01128032 LHBT01228033# LHBT01154071 LHBF07104026 LHBF07204027# LHBF07202039 LHBT01124024 LHBT01224034#
Lamp Type
1x14W T5 FTL 2x14W T5 FTL 1x28W T5 FTL 2x28W T5 FTL 1x54W T5 FTL 1x36/40W FTL 2x36/40W FTL 2x18/20W FTL 1x24W FTL 2x24W FTL
Wattloss (W)
4.0 5.0 6.0 12.0 6.0 5.0 10.0 6.0 5.0 6.0
Power Factor
>0.95 >0.95 >0.95 >0.95 >0.95 >0.95 >0.95 >0.95 >0.95 >0.95
# Independent lamp opration feature available in electronic ballast suitable for twin FTL.
Accessories
21
Advantages:
1152
Ballast is pre-wired, compact in size, energy efcient and with universal mounting holes for easy replacement of electromagnetic ballast. Ideal for areas of low voltage pick-ups.
402
301
L N
Ordering Code
LHBF27904025
Lamp Type
1x36/40W FTL
Wattloss (W)
5.0
Power Factor
>0.94
L N
Accessories
22
Industrial electronic digital performance ballast suitable for single or twin T12/T10/T8/T5 linear uorescent lamps. Designed for specic hum-free application areas where much lower harmonic distortion desirable.
Suitable for 220-240V/ 50Hz Ignition time <2 secs Crest Factor (CF) <1.75 Output Frequency >40KHz High power factor (PF) >0.98 Total Harmonic Distortion (THD) <10% IR radiation immune, hum free operation Circuit designed for higher (300V) mains voltage & ageing protection
Advantages:
H
CD Top View
Longer lamp life Push-fit type connector Striation free operation Low energy consumption with low heat generation Programmed APFC regulated high frequency ballast perfect for multiple switching cycles Conforms to EN 60928 & EN 60929
Dimension Details
Lamp Type
2x14W T5 FTL 2x24W T5 FTL HO 1x28W T5 FTL 2x28W T5 FTL SLIM 2x28W T5 FTL 1x36/40W FTL 2x36/40W FTL
L Side View
Length (L in mm)
305 365 265 265 365 305 305
Width (W in mm)
30 30 28 28 30 30 30
Height (H in mm)
28 28 24 24 28 28 28
CD (in mm)
2961 3551 2541 2541 2961 2961 2961
L N E
Lamp
BALLAST
Ordering Code
LHBT02214049 LHBT02224042 LHBT02128050 LHBT03128050 LHBT02228051 LHBF08104028 LHBF08204029
Lamp Type
2x14W T5 FTL 2x24W T5 FTL HO 1x28W T5 FTL 1x28W T5 FTL SLIM 2x28W T5 FTL 1x36/40W FTL 2x36/40W FTL
Wattloss (W)
6.0 7.0 7.0 7.0 10.0 6.0 10.0
Power Factor
>0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98
Accessories
23
EN60929,
EN55015,
Advantages
Energy savings by dimming capabilities (1-100% T8, 3-100% T5, 5-100% FP-L) 50% Longer lamp life than with conventional ballasts Desired illumination levels creating efcient working conditions Auto reset after lamp replacement comforms to EN 60928 & EN 66929
30.31
3471
Electronic Analog Dimmable Ballast
dimmable
Top View
27.31
Ordering Code
ACUBP0514004 ACUBP0524004 ACUBT0513504 ACUBT0523504 ACUBF0515804 ACUBF0525804
Lamp Type
1x18, 30, 36W T8 FTL 1x18, 24, 36, 40W FP-L 2x18, 30, 36W T8 FTL 2x18, 24, 36, 40W FP-L 1x14, 21, 28, 35W T5 2x14, 21, 28, 35W T5 1x54W T5 1x58W T8 2x54W T5 2x58W T8
Power Factor
>0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98
Dimming Level
1%-100% 5%-100% 1%-100% 5%-100% 3%-100% 3%-100% 3%-100% 3%-100% 3%-100% 3%-100%
Accessories
24
Ignitors
Electronic ignitors for variety of gas discharge lamps of multiple wattages.
Specication
Designed to give reliable initial ignition voltage pulse to facilitate the discharge in HID arc tubes. Active until the lamp current sets in Designed voltage peak occur at the correct phase angle for ignition HF pulses can be transfered only over short distance as per the Approved load capacity of Ign (pF) guidance below Distance(m) = Actual supply line capacity (pF) Impulse (semi - parallel) & Superimposed pulse SIP (series/parallel) versions available. Seperate wired lead for direct ballast terminations eliminates voltage (pulse) drops at multiple junctions. Short and long distance versions ensure quick and reliable ignition to most of HID lamps under 220/230/240V, 50Hz mains supply conditions. For hard strike lamps (aged lamps /MH) higher pulse amplitude may be necessary. Complies with EN 60926 (safety) and EN 60927 (Performance)
Wiring Diagram
LHNM05000D99/ LHNM07000D99
Dimension Details
Ordering Code
LHNM05000D99 LHNW17000B99 LHNW27000C99 LHNM05000E99 LHNM07000D99
Description
3 lead ignitor (SD) 3 lead ignitor (LD) S.I 3 lead ignitor with stud (Al. Can) S.I 2 lead ignitor with stud D type 3 lead ignitor with stud
Lamp Type
Upto 400W HPSV/MH Upto 400W HPSV/MH Upto 400W HPSV/MH Upto 400W HPSV/MH Upto 400W HPSV/MH
Length (L)
54 69 84.5 72.5 36
Dia (D)
39 39 35 38.5 62
Ordering Code
Description
Lamp Type
No. of Pulses
LHNM05000D99 LHNW17000B99
LHNM05000E99
3 lead ignitor (SD) 3 lead ignitor (LD) S.I 3 lead ignitor with stud (Al. Can) S.I 2 lead ignitor with stud D type 3 lead ignitor with stud
Upto 400W HPSV/MH Upto 400W HPSV/MH Upto 400W HPSV/MH Upto 400W HPSV/MH Upto 400W HPSV/MH
1 per cycle 3 per 5 cycle 6 per cycle 5 per cycle 1 per cycle
Accessories
25
Capacitors
Specication
Housing made up of PVC Film used is MPP (Metallised Poly Propylene) With in-built resistant for protection Wire-end soldered for easy connections
CAPACITOR IS:1569-1976 4 MFD 10% 250 V AC 50 Hz -10/85/21 MPP.SP. HAVELLS INDIA LTD.
Ordering Code
LHZF07104099 LHZF07108099 LHZZ07110099 LHZZ07115099 LHZZ07120099 LHZZ07133099 LHZZ07142099
Type
4 MFD 8 MFD 10 MFD 15 MFD 20 MFD 33 MFD 42 MFD
Length (L in mm)
58 58 58 58 74 75 76
Dia (D in mm)
30 30 35 35 40 40 44
Tolerance
10% 10% 10% 10% 10% 5% 5%
Accessories
26