Job No.

Data
New Slab

DT/18 fck Panel Type Slab Thickness Short Span (lx) Long Span (ly) Span / deff Proceed with design 415 147 147 297 147 10
mm c/c mm c/c mm c/c mm c/c mm c/c

DESIGN OF TWO-WAY SLAB (Limit State Method)


30 9 220 4.570 8.210 26
N/mm2

Slab 1.5

S11

Clear Cover

25

mm

Load Factor

mm m m

Working Loads Dead Load 5.5 Live Load 2.00 Finish Load 2.50 W/proof Load 0.20

KN/m2 KN/m2 KN/m2 KN/m2

Design Parameters 26 Mod Span / deff 10.20 Total Load 1.796 ly / lx 4.760 Effective Span

KN/m2 m

Design

Rebars: fy & Dia Spacing (Strength) (Deflection) (IS 456) Critical spacing Provide spacing

415 165 190 165

8
mm c/c mm c/c mm c/c mm c/c

415

8
mm c/c

415

10
mm c/c

190 190

mm c/c mm c/c mm c/c

297 297

mm c/c mm c/c mm c/c

Short Bars at Bottom Strength aspects Effective depth Coeff. Alpha Ultimate BM xu / d xumax / d Reinforcement Area of bars Deflection aspects Service Stress Allowable Span/ deff Reinforcement Area of bars IS 456 guidelines Reinforcement Spacing of bars Max Spacing 190.0 0.101 35.117 0.094 0.479 0.280 5.33 240.7 39.70 0.280 5.33 0.12 297.5 297.5
mm KNm/m

Long Bars at Bottom 181.0 0.056 19.413 0.056 0.479 0.168 3.04
mm KNm/m

Short Bars at Support 191.0 0.000 0.000 0.000 0.479 0.000 0.00
mm KNm/m

Long Bars at Support 182.0 0.000 0.000 0.000 0.479 0.000 0.00
mm KNm/m

% cm2/m

% cm2/m

% cm2/m

% cm2/m

N/mm2 >= % cm2/m

24.05

% mm c/c mm c/c

0.12 190.4 190.4

% mm c/c mm c/c

0.12 190.4 190.4

% mm c/c mm c/c

0.12 297.5 297.5

% mm c/c mm c/c

Application: TWSlabDesign.xls

Developed by: Umesh Dhargalkar

DESIGN OF S.S. TWO-WAY SLAB (Limit State Method)

Notes
1. This application can be used for designing two-way slabs as per Table 26, IS-456: 2000 2. Cells with yellow fill are for data input. 3. Data should be entered in specified units only.

Steps for use


1. Enter required data: Materials, panel type, slab dimensions and loads. 2. Enter first choice for reinforcement at bottom and top 3. If "Proceed with design" message appears, click Design button, else revise slab thickness or grade of reinforcement. 4. For bars at bottom (short and long) as well bars at top (short and long), the spacing required from the aspects of strength, deflection and provisions of IS 456 are displayed. Critical spacing is also displayed. 5. Choose spacing based on the displayed values, else change the slab thickness or grade of reinforcement and take more trials. 6. To proceed to the next slab, click New Slab button and repeat the above steps.

Application: TWSlabDesign.xls

Developed by: Umesh Dhargalkar