Residencial

Iluminacin
Ducha
televisor
refrigerador
radio
Plancha

Descripcin

Categoria residencial pequea


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
400
0
100
250
50
0
800

0.40
0.00
0.10
0.25
0.05
0.00
0.80

0.6
0.8
0.8
0.2
0.8
0.2

0.24
0.00
0.08
0.05
0.04
0.00
0.41

Categoria residencial Mediana


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem

T. de Servicio
8
1.5
6
24
3
1.5

T. de Servicio

Iluminacin
Ducha

800
2500

0.80
2.50

0.6
0.8

0.48
2.00

12
1.5

computadora
televisor
refrigerador
Plancha
lavadora
Bomba de agua
microondas

250
200
250
400
650
375
1000

0.25
0.20
0.25
0.40
0.65
0.38
1.00

0.6
0.8
0.2
0.2
0.7
1
0.8

0.15
0.16
0.05
0.08
0.46
0.38
0.80

5
6
24
1.5
2
8
2

6425

6.43

Residencial
Iluminacin
Ducha
computadora
televisor
refrigerador
Bomba de agua
radio
Plancha
Ventilador
lavadora

4.55

Categoria residencial Grande


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
1200
5000
750
300
500
750
200
800
900
800

1.20
5.00
0.75
0.30
0.50
0.75
0.20
0.80
0.90
0.80

0.6
0.8
0.6
0.8
0.2
1
0.8
0.2
0.7
0.7

0.72
4.00
0.45
0.24
0.10
0.75
0.16
0.16
0.63
0.56

T. de Servicio
12
2
6
6
24
12
5
2
6
2

Aire acondicionado
microondas

750
2000
13950

0.75
2.00
13.95

0.6
0.8

0.45
1.60
9.82

6
4

COMERCIAL

Tiendas
luminarias
Refrigerador

Restaurante
luminarias
Refrigerador
congeladora
Eq. de Sonido
televisor

Oficina
luminarias
Radio
televisor

Categoria Comercial Tienda


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
700
900
1600

0.70
0.90
1.60

0.7
0.4

0.49
0.36
0.85

Categoria comercial Restaurante


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
700
900
800
600
150
3150

0.70
0.90
0.80
0.60
0.15
3.15

0.6
0.2
0.3
0.6
0.8

0.42
0.18
0.24
0.36
0.12
1.32

Categoria comercial Oficina


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
900
100
200
1200

0.90
0.10
0.20
1.20

0.6
0.6
0.8

0.54
0.06
0.16
0.76

T. de Servicio
4
24

T. de Servicio
6
24
6
4
5

T. de Servicio
6
3
5

GENERAL

Alojamiento
luminarias
Eq. de seguridad
Ducha
Televisores

Colegio

Categoria comercial alojamiento


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
1600
150
5000
600
7350

1.60
0.15
5.00
0.60

0.6
1.0
0.8
0.8

0.96
0.15
4.00
0.48
5.59

Categoria general Colegio


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem

T. de Servicio
6
4
1.5
4

T. de Servicio

iluminacion externa
iluminacion interna
fotocopiadoras
30 computadoras
impresora
bomba de agua

Alcaldia
alumbrado
fotocopiadoras
computadoras
Aire acond.
impresora
aspiradora
cafetera
Microondas
bomba de agua

Iglesia
alumbrado
reflectores
equipo sonido

Biblioteca
iluminacion
computadoras
impresora
vetiladora

1500
3600
250
9000
300
750
15400

1.50
3.60
0.25
9.00
0.30
0.75
15.40

0.8
0.8
0.6
0.3
0.3
0.8
6.2

1.20
2.88
0.15
2.70
0.09
0.60
7.62

Categoria general Alcaldia


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
3600
1600
1800
1500
600
150
150
1000
750
11150

3.60
1.60
1.80
1.50
0.60
0.15
0.15
1.00
0.75
11.15

0.8
0.6
0.8
0.9
0.6
0.6
0.5
0.3
0.9

2.88
0.96
1.44
1.35
0.36
0.09
0.08
0.30
0.68
8.13

Categoria general Iglesia


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
1000
400
450
1850

1.00
0.40
0.45
1.85

0.9
0.8
0.4

0.90
0.32
0.18
1.40

Categoria general Biblioteca


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
3000
2100
300
1200
6600

3.00
2.10
0.30
1.20
6.60

0.6
0.5
0.3
0.4

1.80
1.05
0.09
0.48
3.42

6
4
1
2
1
4

T. de Servicio
6
0.5
1
0.5
0.5
0.5
0.5
1
2

T. de Servicio
6
4
0.5

T. de Servicio
6
0.5
0.5
0.5

Industrial

Metal Mecanica

Categoria Industrial Metal Mecanica


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem

T. de Servicio

iluminacion
Soldadora 1
Soldadora 2
Esmeril
Taladro
Torno
Fresa

Carpinteria
iluminacion
mortajadora
Esmeril
Taladro
cepilladora
sierra circular

Taller de pintura
Iluminacion
compresor de aire
pulidora
ventiladora grande
amoladora
bomba de agua

Descripcion
luminarias
plaza

1200
7500
5500
550
750
5500
7500
27300

1.20
7.50
5.50
0.55
0.75
5.50
7.50

0.60
0.9
0.8
0.6
0.6
0.6
0.6
27.2

0.72
6.75
4.40
0.33
0.45
3.30
4.50
19.73

Categoria Industrial Carpinteria


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
1200
1500
550
750
7500
10000
21500

1.20
1.50
0.55
0.75
7.50
10.00
21.50

0.60
0.80
0.60
0.60
0.90
0.60

6
0.4
0.4
0.3
0.25
0.5
0.5

T. de Servicio

0.72
1.20
0.33
0.45
6.75
6.00
15.45

6
0.3
0.3
0.3
0.25
0.25

Categoria Industrial Taller de pintura


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
T. de Servicio
1200
6000
800
1200
750
750
10700

1.20
6.00
0.80
1.20
0.75
0.75
10.70

0.6
0.6
0.5
0.5
0.5
0.7

0.72
3.60
0.40
0.60
0.38
0.53
6.22

Categoria Alumbrado Publico


Demanda
Mxima
Pot.Inst (W) Pot.Inst (KW)
f dem
9600
1000
10600

9.60
1.00
10.60

1.00
1.00

9.60
1.00
10.60

6
0.3
0.3
0.3
0.3
0.5

T. de Servicio
12
12

CATEGORIA RESIDENCIAL
Energia KWh
Diaria
Mensual
1.92
57.60
0.00
0.00
0.48
14.40
1.20
36.00
0.12
3.60
0.00
0.00

Descripcion
RS PEQ
RS MED
RS GR
Total

Descripcion

Energia KWh
Diaria
Mensual
5.76
172.80
3.00
90.00
0.75
0.96
1.20
0.12
0.91
3.00
1.60

22.50
28.80
36.00
3.60
27.30
90.00
48.00

Pot.Inst (W) Pot.Inst (KW)


870
6425
13950

0.87
6.43
13.95
21.25

fdem
3.4
3.4
3.4

CATEGORIA COMERCIAL
Pot.Inst (W) Pot.Inst (KW)
fdem

Tienda
restaurante

1600
3150

1.60
3.15

0.9
0.7

oficina

1200

1.20

0.9

TOTAL

5.95
CATEGORIA GENERAL

Descripcion
alojamiento
colegio
alcaldia
iglesia
biblioteca
TOTAL

Pot.Inst (W) Pot.Inst (KW)


7350
15400
11150
1850
6600

7.35
15.40
11.15
1.85
6.60
42.35

fdem
0.9
0.7
0.9

CATEGORIA INDUSTRIA
Descripcion

Energia KWh
Diaria
Mensual
8.64
259.20
8.00
240.00
2.70
81.00
1.44
43.20
2.40
72.00
9.00
270.00
0.80
24.00
0.32
9.60
3.78
113.40
1.12
33.60

Pot.Inst (W) Pot.Inst (KW)

fdem

metal mecanica

27300

27.30

0.9

carpinteria
taller de pintura
TOTAL

21500
10700

21.50
10.70
59.50

0.7
0.9

2.70
6.40

81.00
192.00

Energia KWh
Diaria
Mensual
1.96
58.80
8.64
259.20

Energia KWh
Diaria
Mensual
2.52
75.60
4.32
129.60
1.44
43.20
1.43
42.97
0.60
18.00

Energia KWh
Diaria
Mensual
3.24
97.20
0.18
5.37
0.80
24.00

Energia KWh
Diaria
Mensual
5.76
172.80
0.60
18.00
6.00
180.00
1.92
57.60

Energia KWh

Diaria
7.20
11.52
0.15
5.40
0.09
2.40

Mensual
216.00
345.60
4.50
162.00
2.70
72.00

Energia KWh
Diaria
Mensual
17.28
518.40
0.48
14.40
1.44
43.20
0.68
20.25
0.18
5.40
0.05
1.35
0.04
1.13
0.30
9.00
1.35
40.50

Energia KWh
Diaria
Mensual
5.40
162.00
1.28
38.40
0.09
2.70

Energia KWh
Diaria
Mensual
10.80
324.00
0.53
15.75
0.05
1.35
0.24
7.20

Energia KWh

Diaria
4.32
2.70
1.76
0.10
0.11
1.65
2.25

Mensual
129.60
81.00
52.80
2.97
3.38
49.50
67.50

Energia KWh
Diaria
Mensual
4.32
129.60
0.36
10.80
0.10
2.97
0.14
4.05
1.69
50.63
1.50
45.00

Energia KWh
Diaria
Mensual
4.32
129.60
1.08
32.40
0.12
3.60
0.18
5.40
0.11
3.38
0.26
7.88

Energia KWh
Diaria
Mensual
115.20
3456.00
12.00
360.00

EGORIA RESIDENCIAL
Demanda
Mxima
2.96
21.85
47.43
72.23

TEGORIA COMERCIAL
Demanda
Mxima

T. de Servicio
8
1.5
6
24

T. de Servicio

Energia KWh
Diaria
Mensual
23.66
709.92
32.77
983.03
284.58
8537.40
1733.59
52007.76

Energia KWh
Diaria
Mensual
11.52
345.60
3.31
99.23

1.44
2.21

8
1.5

1.08

6.48

194.40

4.73

24

113.40

3402.00

ATEGORIA GENERAL
Demanda
Mxima
6.62
10.78
10.04
27.43
48.25
85.71

TEGORIA INDUSTRIA
Demanda
Mxima

T. de Servicio
8
1.5
6
24

T. de Servicio

Energia KWh
Diaria
Mensual
52.92
1587.60
16.17
485.10
60.21
1806.30
658.32
19749.60

Energia KWh
Diaria
Mensual

24.57

196.56

5896.80

15.05
9.63
49.25

1.5
6
24

22.58
57.78
1182.00

677.25
1733.40
35460.00

Lugares
Casas pequeas
Casas medianas
Casas Grandes
oficinas
Escuela
Tienda
Metal Mecanica
Total
Alumbrado P.
TOTAL

Zona 1 + Alumbrado Publico


Dem.Max. /Unidad
Cantidad
Dem. Max.
0.87
30
26.10
6.43
25
160.75
13.95
5
69.75
1.20
4
4.80
15.40
1.00
15.40
1.60
4.00
6.40
27.30
1.00
27.30
310.50
10.60
321.10

Fact. Div.Tipico
3.40
3.40
3.40
1.50
1.50
1.50
1.50

DEM. Final
7.68
47.28
20.51
3.20
10.27
4.27
18.20
111.40
10.60
122.00

Determinacion Tran
Factor de diversidad
Coeficiente de simultaneidad
Demanda instalada
Factor de seguridad
Demanda sistema
Tamao del transformador
Transformador

Determinacion Tran
Zona 2 + Alumbrado Publico
Lugares
Casas pequeas
Casas medianas
Casas Grandes
Iglesia
Carpinteria
Taller de pintura
Tienda
Total
Alumbrado P.
TOTAL

Lugares
Casas pequeas
Casas medianas
Casas Grandes
Biblioteca

Dem.Max. /Unidad
0.87
6.43
13.95
1.85
21.50
10.70
1.60
10.60

Cantidad
Dem. Max.
30
26.10
32
205.76
3
41.85
1.00
1.85
2.00
43.00
1.00
10.70
4.00
6.40
335.66
10.60
346.26

Zona 3 + Alumbrado Publico


Dem.Max. /Unidad
Cantidad
Dem. Max.
0.87
35
30.45
6.43
35
225.05
13.95
11
153.45
6.60
1
6.60

Fact. Div.Tipico
3.40
3.40
3.40
1.50
1.50
1.50
1.50

Fact. Div.Tipico
3.40
3.40
3.40
1.50

DEM. Final
7.68
60.52
12.31
1.23
28.67
7.13
4.27
121.80
10.60
132.40

DEM. Final
8.96
66.19
45.13
4.40

Factor de diversidad
Coeficiente de simultaneidad
Demanda instalada
Factor de seguridad
Demanda sistema
Tamao del transformador
Transformador

Determinacion Tran
Factor de diversidad
Coeficiente de simultaneidad
Demanda instalada
Factor de seguridad
Demanda sistema
Tamao del transformador

Taller de pintura
Restaurantes
Tienda
Total
Alumbrado P.
TOTAL

10.70
3.15
1.60

1
3
5

10.60 70
73
91

234

10.70
9.45
8.00
443.70
10.60
454.30

1.50
1.50
1.50
-

7.13
6.30
5.33
143.45
10.60
154.05

Transformador

Determinacion Transformador Zona 1


ctor de diversidad
oeficiente de simultaneidad
emanda instalada
122.00
ctor de seguridad
0.10
emanda sistema
80.52
mao del transformador
ansformador

DETERMINACIN DE LA DEMANDA ACTUAL Y LA DEMANDA AL AO PROY


2.50
0.60
73.20
7.32
32.21
37.89
50 KVA

DEMANDA
32.21

0
32.21
8
55.05

1
32.69
9
62.95

2
33.68
10
73.05

AOS
3
35.22
11
86.05

4
37.38
12
102.88

DETERMINACIN DE LA DEMANDA ACTUAL Y LA DEMANDA AL AO PROY


DEMANDA

Determinacion Transformador Zona 2

ctor de diversidad
oeficiente de simultaneidad
emanda instalada
ctor de seguridad
emanda sistema
mao del transformador
ansformador

2.50
132.40
0.10
87.38

Determinacion Transformador Zona 3


ctor de diversidad
oeficiente de simultaneidad
emanda instalada
154.05
ctor de seguridad
0.10
emanda sistema
101.67
mao del transformador

34.95

0.60
79.44
7.94
34.95
41.12
50 KVA

AOS
0

34.95
8
59.73

35.47
9
68.30

36.55
10
79.26

38.22
11
93.37

40.56
12
111.63

DETERMINACIN DE LA DEMANDA ACTUAL Y LA DEMANDA AL AO PROY


DEMANDA
40.67
2.50
0.60
92.43
9.24
40.67
47.85

0
40.67
8
69.51

1
41.28
9
79.48

2
42.53
10
92.24

AOS
3
44.47
11
108.65

4
47.20
12
129.90

ansformador

50 KVA

demanda maxima proyecto


408.45

Determinacion de la demanda final de proyecto despues de los 15 aos


Sumatoria de las demandas
643.67

factor de diversidad
1.2

Demanda total
536.39

DEMANDA AL AO PROYECTADO
5
40.27
13
124.85

6
44.03
14
153.79

7
48.87
15
192.27

Determinacion Transformador Zona 1


Factor de diversidad
Coeficiente de simultaneidad
Demanda instalada
192.27
Factor de seguridad
0.10
Demanda sistema
126.90
Tamao del transformador
Transformador

2.50
0.60
115.36
11.54
50.76
59.72
75 KVA

DEMANDA AL AO PROYECTADO
5

43.70
13
135.47

47.78
14
166.87

53.03
15
208.63

Determinacion Transformador Zona 2


Factor de diversidad
Coeficiente de simultaneidad
Demanda instalada
Factor de seguridad
Demanda sistema
Tamao del transformador
Transformador

2.50
245.46
0.10
162.00

0.60
147.28
14.73
64.80
76.24
100 KVA

DEMANDA AL AO PROYECTADO
5
50.85
13
157.65

6
55.60
14
194.18

7
61.71
15
242.77

Determinacion Transformador Zona 3


Factor de diversidad
Coeficiente de simultaneidad
Demanda instalada
241.77
Factor de seguridad
0.10
Demanda sistema
159.57

2.50
0.60
145.06
14.51
63.83

Tamao del transformador


Transformador

ues de los 15 aos


Demanda total
536.39

75.09
100 KVA

567
425
213
53

48 hs
452hs
1500 hs
6760 hs

Diagrama de duraci
600
500
400
300
200
100
0
48 hs

Diagrama de duracin de cargas

452hs

1500 hs

6760 hs