Académique Documents
Professionnel Documents
Culture Documents
Up to 14 samples can be titrated in unattended operation with the Stromboli oven sample changer. Repeatability and efficiency is significantly improved and operation becomes simple, as Stromboli is fully controlled by the titrator. Flexible methods allow multiple blank and sample series with statistics.
User Management
All users have their own Homescreen with Shortcuts for One Click start of any task. Routine users can run their Shortcuts to perform routine tasks, but can not accidentally change anything e.g. in the setup. In connection with LabX pro titration PC software the Remote mode offers full support of FDA 21 CFR part 11 regulations.
Samples that do not release water easily or that cause side reactions can be analyzed using external extraction. Predefined methods that offer direct blank determination of the extracting solvent make this application simple. The method database contains METTLER TOLEDO methods for any kind of coulometric Karl Fischer applications.
Bromine Index
One important parameter in quality assurance of petrochemical raw materials and products is the Bromine index. It can easily be determined with utmost accuracy and precision using the elegant coulometric method. The current generator cell and method templates make this application simple and straightforward.
Communication
Liquid and gaseous samples Resources and method database User specific Home Screen with Shortcuts Shortcuts per user Reagent Control Solvent Manager USB printer DIN-A4/US letter / USB-P25 compact paper roll printer USB memory stick / USB barcode reader / USB hub LevelSens LogStraight Fingerprint Reader Stromboli oven sample changer Expert Routine Preprogrammed METTLER TOLEDO methods Standard methods Max. number of user methods External extraction/dissolution dedicated method type Bromine Index determination Number of samples per series Autostart: automatic start after sample addition Max. number of calculations/results per method User defined calculations Statistics of up to 120 samples including result limits check, outlier test Extra statistical functions as max. srel and multiple determinations Recalculation of results Data in Online Screen: time, water count, potential, stirrer speed, consumption, drift Data in measured value table: time, water count, potential, consumption, drift Curves in Online Screen and printout: E-C, E-t, C-t, drift-t, water count-t Number of tasks queued Context sensitive parameter explanation RS-232 User interface and printouts in English, German, French, Spanish, Italian, Chinese, Russian, Polish, Korean, Portuguese LabX titration light and pro LabX pro full FDA 21 CFR part 11 support Ethernet (TCP/IP) COM (serial balance connection) USB host (printer, memory stick, barcode reader, hub) USB client (PC) TTL I/O Integrated Magnetic Stirrer Pump / Stirrer
12 11 6 120 120 40 10 1 1 2 1 1 1 1
Measurement range Resolution / Limits of error Polarization current range Polarization current resolution / Limits of error Ambient temperature Environment Atmospheric humidity Width x depth x height / Weight Titrator dimensions Glass beaker Control and display Touchscreen Drift measurement Application Measurement range (depends on the environResolution ment and handling) Repeatability Polarized sensor input
-2000+2000 mV 0.1 mV / 2 mV 024 A 0.1 A / 0.1 A +5+40 C max. 80% at 31 C 210 x 340 x 312 mm / 3.3 kg 200 mL VGA 5.7" color TFT, 320 x 240 pixel Online, < 2 g/min 10 g200 mg 0.1 g 0.3% at >1 mg H2O
Mettler-Toledo AG, Analytical CH-8603 Schwerzenbach, Switzerland Tel. +41 44 806 77 11 Fax +41 44 806 72 40 Subject to technical changes 01/2011 Mettler-Toledo AG Printed in Switzerland 51725102B Marketing Titration / MarCom Analytical
www.mt.com/titration
For more information