Vous êtes sur la page 1sur 176

GRUNDFOS DATA BOOKLET

TP, TPD, TPE


In-line circulator pumps
60 Hz

TP, TPD, TPE

Table of contents

1.

2.

3.

4.

5.

6.

7.

8.

9.

Pump data

Introduction
Type key
Codes for shaft seal

4
5
5

Performance range

Performance range, 2-pole, PN 6, 10, 16


Performance range, 4-pole, PN 6, 10, 16
Performance range, 2-pole, PN 25
Performance range, 4-pole, PN 25

6
7
8
9

Product range

10

Product range, 2-pole, PN 6, 10, 16


Product range, 4-pole, PN 6, 10, 16
Product range, 2-pole, PN 25
Product range, 4-pole, PN 25

10
12
14
15

Operating conditions

16

System and test pressures


Sound pressure level
Ambient temperature
Installation altitude

16
16
16
17

Affinity equations

14. TP, TPE pumps in parallel


Control of TP, TPE pumps connected in parallel

15. Grundfos CUE


TP pumps connected to Grundfos CUE, external
frequency converters

16. Motor data


Motor
Electrical data, mains-operated motors
Electrical data, speed-controlled motors

17. Installation
Mechanical installation
Electrical installation

20. Flanges for TP pumps

TP Series 200 pumps

21

21. Curve charts

Technical data
Construction
Materials
Mechanical shaft seal
Connections
Features and benefits

21
21
21
22
22
22

TP Series 300 pumps

23

Technical data
Construction
Materials
Mechanical shaft seal
Connections
Features and benefits

23
23
23
24
24
24

TP Series 400 pumps

25

Technical data
Construction
Materials
Mechanical shaft seal
Connections
Features and benefits

25
25
25
26
26
26

TPE Series 1000 pumps

27

Technical data
Construction
Applications

27
27
27

32

Description of selected functions

37

Communication with TPE pumps

55
55

57

58
58

59
59
60
63

64
64
67

78

EMC and proper installation

18
19

11. User interfaces for TPE pumps

57

19. EMC

Liquid temperature
List of pumped liquids

30

56

68

18

10. Overview of functions

56

18. MGE motors

Pumped liquids

12. Communication

13. Speed regulation of TPE pumps

Flange dimensions

How to read the curve charts


Curve conditions

78

79
79

80
80
81

22. Performance curves/technical data

82

TP, TPD, TPE 2-pole, PN 6, 10, 16


TP, TPD, TPE, 4-pole, PN 6, 10, 16
TP, 2-pole, PN 25
TP, 4-pole, PN 25

82
98
130
132

23. Weights and shipping volume

142

TP, TPD, TPE, 2-pole, PN 6, 10, 16


TP, TPD, TPE, 4-pole, PN 6, 10, 16
TP, 2-pole, PN 25
TP, 4-pole, PN 25

142
144
146
146

24. Minimum efficiency index


TP, TPD, TPE, 2-pole, PN 6, 10, 16
TP, TPD, TPE, 4-pole, PN 6, 10, 16
TP, PN 25

25. Accessories
Counter flanges
Base plates
Blanking flanges
Insulating kits
Sensors
MP 204 - advanced motor protection
Control MP 204
Potentiometer
Grundfos GO Remote
CIU communication interface units
CIM communication interface modules
EMC filter

147
147
149
150

151
151
154
156
158
159
161
161
162
162
163
164
164

TP, TPD, TPE

TP, TPD 2-pole, PN 6, 10, 16


TP, TPD 4-pole, PN 6, 10, 16
TP Series 400, 2-pole, PN 25
TP Series 400, 4-pole, PN 25

165
166
167
168
168

27. Key application data

169

Operating conditions

169

28. Further product documentation


WebCAPS
WinCAPS
GO CAPS

Table of contents

26. Minimum inlet pressure - NPSH

171
171
172
173

TP, TPD, TPE

Pump data

1. Pump data
Introduction

TPE pumps - speed-controlled pumps

TP pumps are designed for applications such as


district heating systems
heating systems
air-conditioning systems
district cooling systems
water supply
industrial processes
industrial cooling.
Most of the pumps are available with either
mains-operated motors (TP and TPD) or electronically
speed-controlled motors (TPE).
The pumps are all single-stage, in-line centrifugal
pumps with mechanical shaft seal. The pumps are of
the close-coupled type, i.e. pump and motor are
separate units.

Based on the construction and choice of material of


TP pumps, Grundfos offers speed-controlled
TPE Series 1000 pumps.
TPE pumps with 2-pole motors below 3 kW and 4-pole
motors below 1.5 kW are fitted with permanent-magnet
motors which have an efficiency that exceeds the IE4
demands - including the energy consumption of the
integrated frequency converter (compared to IE levels
in IEC 60034-30-1 Ed. 1 (CD)).

TP pumps - mains-operated pumps


The TP range is divided into the following four groups
based on their construction: TP Series 100, 200, 300
and 400 pumps.
TP Series 200 with flange connection
DN 32 to DN 100 and motor sizes from 0.12 to 3 kW.
For further information, see page 21.
TP Series 300 with flange connection
DN 32 to DN 200 and motor sizes from 0.55 to 160 kW.
For further information, see page 23.
TP Series 400 with flange connection
Grundfos offers two TP Series 400 versions:
10 bar version with DN 150 to DN 250 flange and
motor sizes from 37 to 132 kW.
25 bar version with DN 100 to DN 250 and motor
sizes from 7.5 to 315 kW.
For further information about TP Series 400 pumps,
see page 25.

TPE Series 1000 pumps


The motors of TPE Series 1000 pumps have a built-in
frequency converter.
Via an external signal (from a sensor or a controller),
TPE Series 1000 pumps allow for any configuration
and control method required: Constant pressure,
constant temperature or constant flow.
For further information, see page 27.
Why select a TPE pump?
A TPE pump with electronic speed control offers these
obvious benefits:
energy savings
increased comfort
control and monitoring of the pump performance
communication with the pump.
ATEX-approved TP pumps
On request, Grundfos offers TP and TPD pumps with
ATEX-approval.
See Key application data, page 169.
High-efficiency motors, IE3
TP pumps are fitted with high-efficiency motors.
TP pumps are primarily fitted with motors that meet the
legislative requirements of the EuP IE3 or IE2 grade
depending on voltage and motor size. For further
information, see Motor, pages 59 to 63.
Energy-optimised pumps
TP pumps are energy-optimised and comply with the
EuP Directive (Commission Regulation (EC)
No. 547/2012) in which most pumps are
classified/graduated in a minimum efficiency index
(MEI). See also page 147.

TP, TPD, TPE

Example

TP

65

-120

/2

-A

-F

-A

Pump data

Type key
-BUBE

Pump range
Electronically speed-controlled pump, Series 1000
Twin-head pump
Nominal diameter of suction and discharge ports (DN)
Maximum head [dm]
Pole number
Code for pump version:
A
= Basic version
I
= PN 6 flange
X
= Special version
Code for pipework connection:
F
= DIN flange
O
= Union
Code for materials:
A
= Basic version
Z
= Bronze pump housing and motor stool
B
= Bronze impeller
Code for shaft seal
(incl. other plastic and rubber components in the pump except the neck ring)

Codes for shaft seal


Example

Grundfos type designation


A
= O-ring seal with fixed seal driver
B
= Rubber bellows seal
D
= O-ring seal, balanced
G
= Bellows seal with reduced seal faces
R
= O-ring seal with reduced seal faces
Material of rotating face
A
= Carbon, antimony-impregnated
B
= Carbon, resin-impregnated
Q
= Silicon carbide
U
= Tungsten carbide
Material of stationary seat
B
= Carbon, resin-impregnated
Q
= Silicon carbide
U
= Tungsten carbide
Material of secondary seal
E
= EPDM
P
= NBR rubber
V
= FKM

Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 81.
The hatched area shows the performance range of TPE pumps.

50

40

30

TM02 5101 3213

10

100
90
80
70
60

32-80

32-160

32-220

32-260

20

200

30

300

15

40

400

32-330

50

500

40-330

32-450

32-550

32-680

60

40-390

32-820

80

100

10

323

12

40-80

50-250

60

40-37
0

15

40-160

40-270
40-240

32-300

TP(D), TPE

PN 6-16, 2-pole, 60 Hz

1000
900
800
700
600

H
[m]

20

50-80

50-160

50-240

50-300

65-80

8 9 10

40

65-160

65-240

65220

50

-34
0

65-540

65

65-390

60

050

20

80

100-300

30

100 120

100-230

80-330

80-640

40

150

100
-53
0

80-750

65-920

80-5
30
80-4
80

80-400

65-740
65630

80-240

80-160

65-1

65-910

80-290

80-200

50-7
9

50-880

50-7
20

65-480

65-260

50
-41
0

40-850

40-93
0

30

50-350

40-740

50-1050

0-3
8

50

Q [m/h]

300

100-630

60 Q [l/s]

200

100-350
100-370

10

10
0 -7
00

Performance range

p
[kPa]

2
TP, TPD, TPE

2. Performance range

Performance range, 2-pole, PN 6, 10, 16

(See page 82 for performance curves.)

40

30

20

400

300

200

50

40

30

20

32-80

32-40

40-80

10

40-40

40
-12
0

40-160

15

50-40

50-110

50-120

50-140

50-190

50-240

30

80-40

80-170

80-230

80-150

60

100-40

80-80

80-110

40

6 7 8 9 10

20

65-40

50-80

65-80

65-130

65-150

65-190

65-230

100
200

20

200

150-170

15
0

300

20
0-

20
01

400

20

20

49
0

03
20
0-3
20
20
028
0

20

90

600

200-400

200

1500

Performance range, 4-pole, PN 6, 10, 16

(See page 98 for performance curves.)

Performance range

Q [l/s]

Q [m/h]

800 1000

150-230

150-250

150-240

44
0

20
050

77
0

39
0

60

20
0-

20
0-

068

20
0-

060
0
20
054
0

20
025
0

430

200-110

150190

200-80

021

150-300

15
034

200
-

40 50 60 70 80 100

150

125-130

30

80 100

100-80

100-100

12
5-1
60

30

100-350
125-360
100-340

400

-44
0

150
150
150
-360

150-180

125
-2

10
0-3
90

100
-290

100-240

100-260

100-150

170

10
0-1
3

100
-

80-280

80-340

-32
0

150-48

0
14
020

TM02 8931 3213

60

32-120

32-140

40-190

40-220

65
-31

65330

125

100470
125-4
30

125-490

10
0 -2
20

10

32-190

50-270

50-340

80-410

80-460

80-510

150-610

150-700

0
53
050
25
0-4
25

100
90
80
70

50

500

TP(D), TPE

PN 6-16, 4-pole, 60 Hz

0
58
025

15

60

80

H
[m]

600

700

p
[kPa]

TP, TPD, TPE

Note: All QH curves apply to single-head pumps. For further information about curve conditions, see page 81.
The hatched area shows the performance range of TPE pumps.

40

50

60

70

80

90

100

150

200

300

TM02 6870 5010

400

500

600

700

800

900

1000

2000

3000

H
[m]

30

25

10

40

PN 25, 2-pole, 60 Hz

TP

50

60

20

80

100

30

100-1000

100-1100

100-1250

100-1450

100-1560

100-1700

100-2100

100-2350

40

150

50

200

60

70

100-1350

80

300

90 100

500

Q [l/s]

Q [m/h]

400

Performance range

p
[kPa]

2
TP, TPD, TPE

Performance range, 2-pole, PN 25

(See page 130 for performance curves.)

90

80

70

60

50

40

30

20

900

800

700

600

500

400

300

200

40

50

60

20

80

30

100

40

150

50

300

60 70 80

200

0
37
512

8 9 10

30

0
27
52
1

125-240

15
037
0

500 600

200-350

400

100

200-520

20
056
0

20
0 -6
70

20
076
0

TM02 7003 5010

20

0
31
512
0
-3 5
25

10

-44
0

00

50
0-4
15

100-210

125

12
5-5

562
0
12
557
0

12

200840

200-930

250-1020

0
49
05
1

100-250

100-330

100-360

100-420

100-450

100-530

100-590

150-710

150-800

150-930

- 37
200

100

100

1000

TP

PN 25, 4-pole, 60 Hz

25
072
0

25
080
0

25
091
0

200

1500

Performance range, 4-pole, PN 25

(See page 132 for performance curves.)

Performance range

300 Q [l/s]

Q [m/h]

800 1000

250-430

0
-50
250

15

H
[m]

50

30

0-5
25

150
-3

p
[kPa]

TP, TPD, TPE

TP, TPD, TPE

Product range, 2-pole, PN 6, 10, 16

10

3 x 380-480 V

3 x 380-500 V

3 x 380-480 V/
3 x 660-690 YV 2

3 x 380-480 V

3 x 220-255 V/
3 x 380-440 YV

P2
P2
P2
P2
[kW] [kW] [kW] [kW]

1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0

P2
[kW]

P2
[kW]

2.2
3.0
4.0
5.5
7.5

2.2

11.0

3.0
4.0
5.5
7.5
11.0

11.0
15.0
18.5

4.0
5.5
7.5
11.0
15.0
18.5

0.55
0.75

Voltage [V]

0.37
0.55
0.75

Voltage [V]

Bronze

Nodular cast iron


EN-GJS-400-15

Cast iron

Stainless steel

Impeller

Bronze

Nodular cast iron


EN-GJS-400-18

Cast iron
EN-GJL-250

PN 25

PN 16

DBUE

Pump housing

GQQE

BQQE

RUUE

BAQE

AUUE

TP Series 400

TP Series 300

BUBE

TP 32-80/2
TP 32-160/2
TP 32-220/2
TP 32-260/2
TP 32-330/2
TP, TPD 32-300/2
TP, TPD 32-360/2
TP, TPD 32-450/2
TP, TPD 32-550/2
TP, TPD 32-680/2
TP, TPD 32-820/2
TP 40-80/2
TP 40-160/2
TP 40-240/2
TP 40-270/2
TP 40-330/2
TP 40-390/2
TP, TPD 40-370/2
TP, TPD 40-450/2
TP, TPD 40-550/2
TP, TPD 40-740/2
TP, TPD 40-850/2
TP, TPD 40-930/2
TP 50-80/2
TP 50-160/2
TP 50-240/2
TP, TPD 50-250/2
TP, TPD 50-300/2
TP, TPD 50-350/2
TP, TPD 50-410/2
TP, TPD 50-720/2
TP, TPD 50-790/2
TP, TPD 50-880/2
TP, TPD 50-1050/2
TP 65-80/2
TP 65-160/2
TP 65-240/2
TP, TPD 65-220/2
TP, TPD 65-260/2
TP, TPD 65-340/2
TP, TPD 65-390/2
TP, TPD 65-480/2
TP, TPD 65-540/2
TP, TPD 65-630/2
TP, TPD 65-740/2
TP, TPD 65-910/2
TP, TPD 65-920/2
TP, TPD 65-1050/2
TP 80-160/2
TP, TPD 80-200/2
TP, TPD 80-240/2
TP, TPD 80-290/2
TP, TPD 80-330/2

TP Series 200

TPE Series 10001

Pump type

Electronically
Mains-operated motor speed-controlled
motor

Materials

3 x 220-277 V/
3 x 380-480 YV

Pressure
stage

Shaft seal

PN 10

Design

PN 6, 10 combination flange

Product range

3. Product range

1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5

4.0
5.5
7.5

0.55

1.1
1.5
2.2
3.0
4.0
5.5
15.0
18.5
22.0
30.0
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
37.0
37.0
3.0
4.0
5.5
7.5
11.0

2.2
3.0
4.0
5.5

2.2

15.0
18.5
22.0
30.0

3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
30.0
37.0
37.0
4.0
5.5
7.5
11.0

3.0
4.0
5.5
15.0
18.5
22.0

3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0

4.0
5.5
7.5
11.0

15.0
18.5
22.0
30.0
37.0
7.5
11.0
15.0
18.5
22.0
30.0
37.0
45.0

15.0
18.5
22.0
30.0
37.0
7.5
11.0
15.0
18.5
22.0
30.0
37.0
45.0

3 x 380-500 V

P2
P2
P2
P2
[kW] [kW] [kW] [kW]

3 x 380-480 V

Voltage [V]
3 x 380-480 V/
3 x 660-690 YV 2

3 x 380-480 V

3 x 220-255 V/
3 x 380-440 YV

Voltage [V]

Bronze

Nodular cast iron


EN-GJS-400-15

Cast iron

Impeller

Stainless steel

Bronze

Nodular cast iron


EN-GJS-400-18

Cast iron
EN-GJL-250

PN 25

PN 16

Pump housing

PN 10

DBUE

RUUE

AUUE

BUBE

TP Series 400

TP Series 300

GQQE

80-400/2
80-480/2
80-530/2
80-640/2
80-750/2
100-230/2
100-300/2
100-370/2
100-350/2
100-380/2
100-530/2
100-630/2
100-700/2

BQQE

TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD

BAQE

TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,

TP Series 200

TPE Series 10001

Pump type

Electronically
Mains-operated motor speed-controlled
motor

Materials

3 x 220-277 V/
3 x 380-480 YV

Pressure
stage

Shaft seal
PN 6, 10 combination flange

Design

Product range

TP, TPD, TPE

P2
[kW]

P2
[kW]

15.0
18.5
22.0

7.5
11.0
15.0
18.5
22.0

Standard
TPE pumps are not available in twin-head versions.
2
2-pole motors above 7.5 kW can be operated at 3 x 660-690 YV. Smaller motor sizes cannot.
1

11

TP, TPD, TPE

TP 32-40/4
TP 32-80/4
TP, TPD 32-120/4
TP, TPD 32-140/4
TP, TPD 32-190/4
TP 40-40/4
TP 40-80/4
TP, TPD 40-120/4
TP, TPD 40-160/4
TP, TPD 40-190/4
TP, TPD 40-220/4
TP 50-40/4
TP 50-80/4
TP, TPD 50-110/4
TP, TPD 50-120/4
TP, TPD 50-140/4
TP, TPD 50-190/4
TP, TPD 50-240/4
TP, TPD 50-270/4
TP, TPD 50-340/4
TP 65-40/4
TP 65-80/4
TP, TPD 65-130/4
TP, TPD 65-150/4
TP, TPD 65-190/4
TP, TPD 65-230/4
TP, TPD 65-310/4
TP, TPD 65-330/4
TP 80-40/4
TP 80-80/4
TP, TPD 80-110/4
TP, TPD 80-150/4
TP, TPD 80-170/4
TP, TPD 80-230/4
TP, TPD 80-280/4
TP, TPD 80-340/4
TP, TPD 80-410/4
TP, TPD 80-460/4
TP, TPD 80-510/4
TP 100-40/4
TP 100-80/4
TP, TPD 100-100/4
TP, TPD 100-130/4
TP, TPD 100-150/4
TP, TPD 100-170/4
TP, TPD 100-200/4
TP, TPD 100-240/4
TP, TPD 100-260/4
TP, TPD 100-290/4
TP, TPD 100-340/4
TP, TPD 100-350/4
TP, TPD 100-390/4
TP, TPD 100-470/4

12

0.12
0.25
0.55
0.75

0.25
0.55
0.75

0.25
0.55
0.75

0.37

P2
[kW]

P2
[kW]

1.1

1.1
1.5
2.2

1.1
1.5
2.2
3.0
4.0
5.5
1.1
1.5
2.2
3.0
4.0
5.5
7.5

3 x 380-500 V

Nodular cast iron


EN-GJS-400-15
Bronze

Cast iron

Stainless steel

P2
P2
P2
P2
[kW] [kW] [kW] [kW]

3 x 380-480 V

Voltage [V]
3 x 380-480 V/
3 x 660-690 YV 2

Voltage [V]
3 x 380-480 V

Electronically
speed-controlle
d motor

3 x 220-277 V/
3 x 380-480 YV

Mains-operated motor

Impeller

Bronze

Cast iron
EN-GJL-250
Nodular cast iron
EN-GJS-400-18

PN 25

DBUE

GQQE

PN 16

BQQE

Pump
housing

BAQE

RUUE

AUUE

BUBE

TP Series 400

TP Series 300

TP Series 200

TPE Series 1000 1

Pump type

Materials

3 x 220-255 V/
3 x 380-440 YV

Pressure
stage

Shaft seal

PN 10

Design

PN 6, 10 combination flange

Product range

Product range, 4-pole, PN 6, 10, 16

1.1

1.1
1.5
2.2

2.2

1.1

5.5

1.5
2.2
3.0
4.0
5.5

5.5
7.5

1.5
2.2
3.0
4.0
5.5
7.5

2.2
3.0
4.0

2.2
3.0
4.0

0.75

1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0
1.1
2.2
3.0
4.0
5.5
5.5
7.5
11.0
11.0
15.0
18.5
22.0
22.0
30.0

1.1
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0

3.0
4.0
5.5
5.5
7.5
11.0
11.0
15.0
18.5
22.0
22.0
30.0

1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5

3.0
4.0
5.5
5.5
7.5
11.0
11.0
15.0
18.5

3.0
4.0
5.5
5.5
7.5
15.0
18.5
22.0
30.0
37.0
11.0
15.0
15.0
18.5
18.5
22.0
22.0
30.0
37.0

7.5
11.0
15.0
18.5
22.0
30.0

3.0
4.0
5.5
5.5
7.5
15.0
18.5
22.0
30.0
37.0
11.0
15.0
15.0
18.5
18.5
22.0
22.0
30.0
37.0
30.0
37.0
45.0
55.0
75.0
90.0
7.5
11.0
15.0
18.5
22.0
30.0
37.0
45.0
55.0
75.0
75.0
55.0
90.0
90.0
110.0
90.0
110.0
132.0
160.0
90.0
110.0
132.0

3 x 380-500 V

Nodular cast iron


EN-GJS-400-15
Bronze

Stainless steel

Cast iron

P2
P2
P2
P2
[kW] [kW] [kW] [kW]

3 x 380-480 V

Voltage [V]
3 x 380-480 V/
3 x 660-690 YV 2

Voltage [V]
3 x 380-480 V

Electronically
speed-controlle
d motor

3 x 220-277 V/
3 x 380-480 YV

Mains-operated motor

Impeller

Bronze

Cast iron
EN-GJL-250
Nodular cast iron
EN-GJS-400-18

PN 25

PN 16

Pump
housing

PN 10

DBUE

RUUE

AUUE

BUBE

TP Series 300

TP Series 400

GQQE

BQQE

BAQE

TP 125-100/4
TP 125-120/4
TP 125-140/4
TP, TPD 125-130/4
TP, TPD 125-160/4
TP, TPD 125-230/4
TP, TPD 125-320/4
TP, TPD 125-360/4
TP, TPD 125-430/4
TP, TPD 125-490/4
TP 150-170/4
TP, TPD 150-180/4
TP 150-190/4
TP, TPD 150-210/4
TP 150-230/4
TP, TPD 150-240/4
TP 150-250/4
TP, TPD 150-300/4
TP, TPD 150-340/4
TP 150-360/4
TP 150-400/4
TP 150-440/4
TP 150-480/4
TP 150-610/4
TP 150-700/4
TP 200-80/4
TP 200-110/4
TP 200-140/4
TP 200-190/4
TP 200-210/4
TP 200-250/4
TP 200-280/4
TP 200-320/4
TP 200-360/4
TP 200-390/4
TP 200-400/4
TP 200-430/4
TP 200-440/4
TP 200-490/4
TP 200-500/4
TP 200-540/4
TP 200-600/4
TP 200-680/4
TP 200-770/4
TP 250-450/4
TP 250-530/4
TP 250-580/4

TP Series 200

TPE Series 1000 1

Pump type

Materials

3 x 220-255 V/
3 x 380-440 YV

Pressure
stage

Shaft seal
PN 6, 10 combination flange

Design

P2
[kW]

P2
[kW]

Product range

TP, TPD, TPE

3.0
4.0
5.5
5.5
7.5
15.0
18.5

11.0
15.0
15.0
18.5
18.5

7.5
11.0
15.0
18.5

Standard
TPE pumps are not available in twin-head versions.
2
4-pole motors above 4 kW can be operated at 3 x 660-690 YV. Smaller motor sizes cannot.
1

13

TP, TPD, TPE

TP 100-1000/2
TP 100-1100/2
TP 100-1250/2
TP 100-1350/2
TP 100-1450/2
TP 100-1560/2
TP 100-1700/2
TP 100-2100/2
TP 100-2350/2

14

Standard

Materials

Mains-operated motor

Electronically
speed-controlled
motor

Voltage [V]

Voltage [V]

3 x 220-255 V/
3 x 380-440 YV

3 x 220-277 V/
3 x 380-480 YV

3 x 380-480 V

3 x 380-480 V/
3 x 660-690 YV

3 x 380-480 V

Impeller

Bronze

Nodular cast iron


EN-GJS-400-18

Cast iron
EN-GJL-250

PN 25

Pump
housing

Stainless steel
Cast iron
Nodular cast iron
EN- GJS-400-15
Bronze

Pressure stage

PN 16

TPE Series 1000

Pump type

Shaft seal

PN 10

Design

TP Series 200
TP Series 300
TP Series 400
BUBE
AUUE
RUUE
BAQE
BQQE
GQQE
DBUE
PN 6, 10 combination flange

Product range

Product range, 2-pole, PN 25

P2
[kW]

P2
[kW]

P2
[kW]

P2
[kW]

P2
[kW]

75.0
90.0
110.0
132.0
110.0
132.0
160.0
200.0
250.0

TP, TPD, TPE

P2
P2
P2
P2
[kW] [kW] [kW] [kW]

3 x 380-480 V

Voltage [V]
3 x 380-480 V/
3 x 660-690 YV

Voltage [V]
3 x 380-480 V

Electronically
speed-controlled
motor

3 x 220-277 V/
3 x 380-480 YV

Cast iron

Stainless steel

Bronze

Nodular cast iron


EN-GJS-400-18

Cast iron
EN-GJL-250

PN 16

PN 25

Mains-operated motor

Impeller

Bronze

PN 10

DBUE

GQQE

BQQE

BAQE

RUUE

AUUE

BUBE

TP Series 300

TP Series 400

Pump
housing

Nodular cast iron


EN- GJS-400-15

TP 100-210/4
TP 100-250/4
TP 100-330/4
TP 100-360/4
TP 100-420/4
TP 100-450/4
TP 100-530/4
TP 100-590/4
TP 125-240/4
TP 125-270/4
TP 125-310/4
TP 125-370/4
TP 125-350/4
TP 125-440/4
TP 125-500/4
TP 125-570/4
TP 125-620/4
TP 150-330/4
TP 150-370/4
TP 150-450/4
TP 150-490/4
TP 150-710/4
TP 150-800/4
TP 150-930/4
TP 200-350/4
TP 200-370/4
TP 200-520/4
TP 200-560/4
TP 200-670/4
TP 200-760/4
TP 200-840/4
TP 200-930/4
TP 250-430/4
TP 250-500/4
TP 250-550/4
TP 250-720/4
TP 250-800/4
TP 250-910/4
TP 250-1020/4

TP Series 200

TPE Series 1000

Pump type

Materials

3 x 220-255 V/
3 x 380-440 YV

Pressure
stage

Shaft seal
PN 6, 10 combination flange

Design

Product range

Product range, 4-pole, PN 25

P2
[kW]

7.5
11.0
15.0
18.5
18.5
22.0
30.0
37.0
15.0
18.5
22.0
30.0
22.0
30.0
37.0
45.0
55.0
30.0
37.0
45.0
55.0
90.0
110.0
132.0
45.0
55.0
75.0
90.0
110.0
132.0
160.0
200.0
90.0
110.0
132.0
160.0
200.0
250.0
315.0

Standard

15

TP, TPD, TPE

Operating conditions

4. Operating conditions
System and test pressures
Pressure

System pressure

Test pressure

[bar]

[MPa]

[bar]

PN 6

0.6

10

[MPa]
1.0

PN 6 / PN 10

10

1.0

16

1.6

PN 16

16

1.6

24

2.4

PN 25

25

2.5

38

3.8

Sound pressure level


Max. sound pressure level [dB(A)] - ISO 3743
Motor
[kW]

Three-phase motors
2-pole

4-pole

0.12

0.25

45

0.37

57

45

0.55

56

45

0.75

57

50.5

1.1

58

50.5

1.5

64

51.5

2.2

65

54.5

3.0

53.5

57

4.0

67.5

56

5.5

68

55

7.5

65

56

11.0

64.5

58

15.0

65

58

18.5

65.5

65

22.0

70.5

65

30.0

75

66

37.0

75

65

45.0

75

65

55.0

75

68

75.0

77

71

90.0

77

71

110.0

81

75

132.0

81

75

160.0

81

75

200.0

81

75

250.0

86

77

315.0

77

The values apply only to MG and Siemens motors.


The values have a tolerance of 3 dB according to
EN ISO 4871. The tolerance is not added to the values
in the table.

16

The audible noise from TP pumps is primarily noise


from the motor fan. The selection of TPE pumps will
reduce the noise at partial load, as the motor and,
consequently, the motor fan runs at a lower speed.
Possible flow noise from control valves is also reduced
at partial load in the case of the TPE pump.

Ambient temperature
MG IE2 and IE3 motors:
0.75 - 22 kW motors, 2-pole
0.75 - 15 kW motors, 4-pole
Siemens IE2 and IE3 motors:
30 - 315 kW motors, 2-pole
18.5 - 315 kW motors, 4-pole
MGE motors:
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
MGE motors:
3 - 22 kW, 2 pole
1.5 - 18.5 kW, 4-pole
Storage:

-30 - +60 C

-20 - +55 C

-20 - +50 C

-20 - +40 C
Down to -30 C

TP, TPD, TPE

Operating conditions

Installation altitude
If the ambient temperature exceeds maximum values
or if the motor is located more than 1000 metres above
sea level, the motor output (P2) must be reduced due
to the low density and consequent low cooling effect of
the air. In such cases, it may be necessary to use an
oversize motor with a higher rated output.
Pos.

Description

Siemens IE2 and IE3 motors:


30 - 315 kW motors, 2-pole
18.5 - 315 kW motors, 4-pole

MG IE2 and IE3 motors:


0.75 - 22 kW motors, 2-pole
0.75 - 15 kW motors, 4-pole
MGE motors:
3 - 22 kW, 2 pole
1.5 - 18.5 kW, 4-pole

Other motor sizes

P2
[%]

100

90
3

80
60
50

20 25 30 35 40 45 50 55 60 65 70 75 80
t [C]
1000

Fig. 1

2250

3500

4750

TM03 2479 4405

70

Relationship between motor output (P2) and


altitude

Description
MGE motors:
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
P2
[%]

1000 1200 1400 1600 1800 2000 2200


Altitude [m]

Fig. 2

TM05 6400 4712

1
0.99
0.98
0.97
0.96
0.95
0.94
0.93
0.92
0.91
0.90
0.89
0.88

Derating of motor output (P2) in relation to altitude


above sea level

Note: If the motor is to operate at ambient


temperatures between 50 and 60 C, an oversized
motor must be selected. Contact Grundfos.

17

TP, TPD, TPE

Pumped liquids

5. Pumped liquids
Thin, clean, non-aggressive and non-explosive liquids,
not containing solid particles or fibres that may
mechanically or chemically attack the pump.
See List of pumped liquids, page 19.
Examples of liquids:
central heating system water (the water should
meet the requirements of accepted standards on
water quality in heating systems)
cooling liquids
domestic hot water
industrial liquids
softened water.
If glycol or another antifreeze agent is added to the
pumped liquid, the pump must have a shaft seal of the
RUUE or GQQE type.
The pumping of liquids with densities or kinematic
viscosities higher than those of water can cause
a considerable pressure drop
a drop in the hydraulic performance
a rise in the power consumption.
In these situations, equip the pump with an oversize
motor. If in doubt, contact Grundfos.
If the water contains mineral oils or chemicals, or if
other liquids than water are pumped, the O-rings
should be chosen accordingly.

Liquid temperature
Liquid temperature: -25 - +150 C.
Please note that shaft seals operating close to their
maximum temperature will require regular
maintenance, i.e. replacement.
Pump type

Shaft seal

TP Series 100

TP Series 200

TP Series 300

Temperature

BUBE
BQQE
GQQE
BUBE
AUUE
RUUE

0-110 C
0-90 C
-25 - +90 C
0-140 C
0-90 C
-25 - +90 C

BAQE

0-120 C (140 C)1


0-90 C

BQQE

TP Series 400.
10 bar version

BAQE
BQQE
GQQE

-25 - +90 C (60 C)2


0-120 C
0-90 C
-25-90 C

TP Series 400:
25 bar version

DBUE

0-150 C3

GQQE

TP Series 300 pumps are designed for a maximum operating


temperature of 140 C. For operation above 120 C, an alternative
shaft seal is to be selected. Contact Grundfos.
The below TP Series 300 pumps with GQQE shaft seals are
designed for a maximum operating temperature of 60 C.
TP
TP
TP
TP
TP
TP
TP
TP

150-360/4
150-400/4
150-440/4
150-480/4
150-610/4
150-700/4
150-810/4
150-960/4

TP
TP
TP
TP
TP
TP
TP
TP
TP

200-400/4
200-430/4
200-440/4
200-490/4
200-500/4
200-540/4
200-600/4
200-680/4
200-770/4

At 120-150 C, the maximum operating pressure is 23 bar.

Depending on the type of cast iron used and the pump


application, the maximum liquid temperature may be
limited by local regulations and laws.

18

TP, TPD, TPE

List of pumped liquids


Grundfos TP and TPD pumps are designed for
circulation systems with constant flow, TPE pumps for
systems with variable flow.
Thanks to their design, the pumps can be used in a
wider liquid temperature range than pumps of the
canned rotor type.
A number of typical liquids are listed below.
Other pump versions may be used, but we consider
the ones stated in the list to be the best choices.
The list is intended as a general guide only, and it
cannot replace actual testing of the pumped liquids
and pump materials under specific working conditions.
If in doubt, we recommend that you fill in the form
shown on page 169 and contact Grundfos.
Use the list with some caution, as factors such as
concentration of the pumped liquid, liquid temperature
or pressure may affect the chemical resistance of a
specific pump version.

Pumped liquids

Legend
May contain additives or impurities that may cause shaft seal
problems.
The density and/or viscosity differ from those of water.
B
Consider this when calculating motor and pump performance.
A

C The liquid must be oxygen-free (anaerobic).


D Risk of crystallisation/precipitation in shaft seal.
E Insoluble in water.
F

The shaft seal rubber parts must be replaced with FKM rubber.

G Bronze housing/impeller required.


H

Risk of formation of ice on the standby pump.


(The risk only applies to TP, TPE Series 200 pumps).

Shaft seal
Pumped liquids

Notes

Additional information
TP Series 200

TP Series 300

TP Series 400
PN 10

TP Series 400
PN 25

DBUE

Water
< 90 C
Groundwater

> 90 C

Boiler-feed water

AUUE

BQQE

BUBE

BAQE1
BBQE2

BAQE
BAQE

< 20 C

BUBE

BAQE

< 40 C

BUBE

DAQF2

< 120 C

BUBE

BAQE

< 90 C

AUUE

BQQE

> 90 C

BUBE

BAQE

< 90 C

AUUE

BQQE

> 90 C

BUBE

BAQE

pH > 6.5, 40 C,
1000 ppm Cl-

BUBE
AUUE

BQQE

RUUE

GQQE

RUUE

GQQE

RUUE

GQQE

RUUE

GQQE

< 90 C

RUUE

< 5 C, 30 %

< 150 C
District heating water
Condensate
Softened water

Brackish water

DBUE
DBUE
DBUE

BAQE

DBUE

BAQE

DBUE

BAQE

DBUE

BQQE

DBUE

GQQE

DQQE2

GQQE

DQQE2

GQQE

DQQE2

GQQE

DQQE2

GQQE

GQQE

DQQE2

RUUE

GQQE

GQQE

DQQE2

BUBE
AUUE

BAQE
BQQE

BAQE

DBUE

Coolants
Ethylene glycol

B, D, H

Glycerine (glycerol)

B, D, H

Potassium acetate

B, D, C, H

Potassium formate

B, D, C, H

Propylene glycol
Brine sodium chloride

B, D, H
B, D, C, H

< 120 C
< 90 C

DQQE

< 120 C
< 90 C

DQQE

< 120 C
< 90 C

DQQE

< 120 C
< 90 C

DQQE

< 120 C

DQQE

Synthetic oils
Silicone oil

B, E

(To be continued)

19

TP, TPD, TPE

Pumped liquids

Shaft seal
Pumped liquids

Notes

Additional information
TP Series 200

TP Series 300

TP Series 400
PN 10

TP Series 400
PN 25

BUBV2
AUUV2

BAQV2
BQQV2

BAQV2

DBUV2

BUBV2
AUUV2

BAQV2
BQQV2

BAQV2

DBUV2

Vegetable oils
Corn oil

B, F, E

Olive oil

B, F, E

Peanut oil

B, F, E

BUBV2
AUUV2

BAQV2
BQQV2

BAQV2

DBUV2

D, B, F, E

BUBV2
AUUV2

BAQV2
BQQV2

BAQV2

DBUV2

B, F, E

BUBV2
AUUV2

BAQV2
BQQV2

BAQV2

DBUV2

Rapeseed oil
Soybean oil

< 80 C

Cleaning agents
Soap (salts of fatty acids)

A, E, (F)

< 80 C

AUUE
(AUUV)2

BQQE
(BQQV)2

GQQE

DQQE2

Alkaline degreasing agent

A, E, (F)

< 80 C

AUUE
(AUUV)2

BQQE
(BQQV)2

GQQE

DQQE2

< 40 C, < 2 %

BUBE
AUUE

BQQE

BQQV2

DQQE2

DQQE2

Oxidants
Hydrogen peroxide
Salts
Ammonium bicarbonate
Calcium acetate
Potassium bicarbonate

< 20 C, < 15 %

AUUE

BQQE

GQQE

A, B

< 20 C, < 30 %

AUUE

BQQE

GQQE

DQQE2

< 20 C, < 20 %

AUUE

BQQE

GQQE

DQQE2

Potassium carbonate

< 20 C, < 20 %

AUUE

BQQE

GQQE

DQQE2

Potassium permanganate

< 20 C, < 10 %

AUUE

BQQE

GQQE

DQQE2

Potassium sulphate

< 20 C, < 20 %

AUUE

BQQE

GQQE

DQQE2

Sodium acetate

< 20 C, < 100 %

AUUE

BQQE

GQQE

DQQE2

Sodium bicarbonate

< 20 C, < 2 %

AUUE

BQQE

GQQE

DQQE2

Sodium carbonate

< 20 C, < 20 %

AUUE

BQQE

GQQE

DQQE2

Sodium nitrate

< 20 C, < 40 %

AUUE

BQQE

GQQE

DQQE2

Sodium nitrite

< 20 C, < 40 %

AUUE

BQQE

GQQE

DQQE2

Sodium phosphate (di)

< 100 C, < 30 %

AUUE

BQQE

GQQE

DQQE2

Sodium phosphate (tri)

< 90 C, < 20 %

AUUE

BQQE

GQQE

DQQE2

Sodium sulphate

< 20 C, < 20 %

AUUE

BQQE

GQQE

DQQE2

Sodium sulphite

< 20 C, < 1 %

AUUE

BQQE

GQQE

DQQE2

< 100 C, < 30 %

AUUE

BQQE

GQQE

DQQE2

< 100 C, < 10 %

AUUE

BQQE

GQQE

DQQE2

Alkalis
Ammonium hydroxide
Calcium hydroxide

20

Potassium hydroxide

< 20 C, < 20 %

AUUE

BQQE

GQQE

DQQE2

Sodium hydroxide

< 40 C, < 20 %

AUUE

BQQE

GQQE

DQQE2

BAQE must not be used for potable water. For potable water, Grundfos recommends a BBQE shaft seal.

The shaft seal is not standard, but available on request.

Maximum 110 C.

TP, TPD, TPE

TP Series 200 pumps

6. TP Series 200 pumps


Materials

GR8261

TP, TPE Series 200

3
TM03 1211 1405

Fig. 3

TP Series 200
2
1

Technical data
Flow rate:
Head:
Liquid temperature:
Max. operating pressure:
Direction of rotation:

Up to 90 m3/h
Up to 27 m
-25 - +140 C
Up to 16 bar
Counter-clockwise

Construction
Grundfos TP Series 200 pumps are single-stage,
close-coupled pumps with inline suction and discharge
ports of identical diameter.
The pumps are equipped with a fan-cooled
asynchronous motor. Motor and pump shafts are
connected via a rigid two-part coupling.
TP Series 200 pumps have flange connection and are
equipped with PN 6 or PN 10 flanges.
The pumps are equipped with an unbalanced
mechanical shaft seal.
The pumps are of the top-pull-out design, i.e. the
power head (motor, pump head and impeller) can be
removed for maintenance or service while the pump
housing remains in the pipework.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
TP Series 200 pumps are equipped with
high-efficiency motors.
Pumps with bronze pump housing (version B) are
suitable for circulation of domestic hot water.

Fig. 4

Sectional drawing of a TPE Series 200 (flanged


model)

Material specification, Series 200


Pos. Component

Material

EN/DIN

Cast iron EN-GJL-250,


bronze CuSn10

0.6020
2.1093

Pump housing

Impeller

Stainless steel

1.4301

Shaft

Stainless steel

1.4305

Coupling

Cast iron EN-GJL-400

0.7040

Pump head

Cast iron EN-GJL-250,


bronze

0.6025
2.1093

Secondary seals EPDM


Rotating seal
face

Tungsten carbide

Stationary seat

Carbon (resin-impregnated),
silicon carbide

21

TP, TPD, TPE

TP Series 200 pumps

Mechanical shaft seal

Features and benefits

Three types of unbalanced mechanical shaft seals are


available as standard:
BUBE
The BUBE shaft seal is a Grundfos rubber bellows
seal with tungsten carbide/carbon seal faces and
secondary seals of EPDM.
RUUE/GQQE
The RUUE shaft seal is a Grundfos O-ring seal with
reduced tungsten carbide/tungsten carbide seal
faces and secondary seals of EPDM.
The GQQE shaft seal is a Grundfos rubber bellows
seal with reduced silicon carbide/silicon carbide
seal faces and secondary seals of EPDM.
AUUE/BQQE
The AUUE shaft seal is a Grundfos O-ring seal with
fixed seal driver, tungsten carbide/tungsten carbide
seal faces and secondary seals of EPDM.
The BQQE shaft seal is a Grundfos rubber bellows
seal with silicon carbide/silicon carbide seal faces
and secondary seals of EPDM.
Information on a selection of common pumped liquids
with recommended shaft seals is shown on page 19.

TP Series 200 pumps have the following product


features and benefits:

Shaft seal specification


Unbalanced shaft
seal
Shaft diameter
Rubber bellows

TP, TPD
Series 200

Seal faces

Version NU according to EN
12756
12 and 16 mm
EPDM
Tungsten carbide/carbon
Tungsten carbide/
tungsten carbide
Silicon carbide/
silicon carbide

Special shaft seals are available for partly conditioned


water or other liquids containing abrasive or
crystallising particles. See page 19.

Connections
TP Series 200 pumps up to DN 65 are equipped with
combination flanges PN 6/PN 10. DN 80 or DN 100
pumps have either PN 6 or PN 10 flanges. All flanges
can be connected to flanges in accordance with EN
1092-2 and ISO 7005-2.

22

Optimised hydraulics for high efficiency


- reduced power consumption.
High-efficiency motors
- TP pumps are fitted with high-efficiency motors.
High-efficiency motors offer reduced energy
consumption.
TP pumps are primarily fitted with motors that
meet the legislative requirements of the EuP IE3
grade. For further information, see Motor, pages
59 to 63.
Top-pull-out design
- easy dismantling in case of service.
In-line design
- contrary to end-suction pumps, in-line pumps
allow a straight pipework and thus often reduced
installation costs.
Pump housing and pump head are electrocoated
to improve the corrosion resistance
- Electrocoating includes:
Alkaline cleaning
Pre-treatment with zinc phosphate coating
Cathodic electrocoating (epoxy)
Curing of paint film at 200-250 C.
For low-temperature applications at a high
humidity, Grundfos offers TP pumps with extra
surface treatment to avoid corrosion.
These pumps are available on request.
Stainless steel impeller and neck ring
- wear-free operation with high efficiency.

TP, TPD, TPE

TP Series 300 pumps

7. TP Series 300 pumps

GR8259

TM04 9586 4610

Materials

Fig. 5

TP Series 300
Fig. 6

Technical data
Flow rate:
Head:
Liquid temperature:
Max. operating pressure:
Direction of rotation:

Sectional drawing of TP Series 300

Material specification
m3/h

Up to 850
Up to 93 m
-25 - +140 C
16 bar
Clockwise

Construction
Grundfos TP, TPD Series 300 pumps are single-stage,
close-coupled pumps with in-line suction and
discharge ports of identical diameter.
The pumps are equipped with a fan-cooled
asynchronous motor. Motor and pump shafts are
connected via a rigid sleeve coupling.
Most TP Series 300 pumps are available as
single-head (TP) and twin-head (TPD) models.
TP Series 300 pumps have flange connection and are
equipped with PN 16 flanges.
The pumps are equipped with an unbalanced
mechanical shaft seal.
The pumps are of the top-pull-out design, i.e. the
power head (motor, pump head and/or motor stool and
impeller) can be removed for maintenance or service
while the pump housing remains in the pipework.
The pump housing is provided with replaceable wear
rings to ensure high pump efficiency for life.
The twin-head pumps are designed with two parallel
power heads. A non-return flap valve in the common
discharge port is opened by the flow of the pumped
liquid and prevents backflow of liquid into the idle
pump head.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
The impeller is hydraulically balanced to minimise axial
forces.
TP, TPD, TPE Series 300 pumps are equipped with
high-efficiency motors.
TP Series 300 pumps with bronze impeller are suitable
for pumping brine.

Pos. Component

Material

EN/DIN

Pump housing

Cast iron EN-GJL-250

EN-JL 1040

Impeller

Cast iron EN-GJL-200,


bronze CuSn5Zn5Pb

EN-JL 1030
2.1096.01

Stub shaft
2-part stub shaft

Stainless steel
Stainless steel/steel

Pump head/
motor stool

Cast iron EN-GJL-250

Secondary seals

EPDM

Rotating seal face

Metal-impregnated carbon,
silicon carbide

Stationary seat

Silicon carbide

Wear rings

Bronze CuSn10

1.4301
1.4301/1.0301
EN-JL 1040

2.1093

23

TP, TPD, TPE

TP Series 300 pumps

Mechanical shaft seal

Features and benefits

Three types of unbalanced mechanical shaft seal are


available as standard:
BAQE
The BAQE shaft seal is a Grundfos rubber bellows
seal with carbon/silicon carbide seal faces and
secondary seals of EPDM.
GQQE
The GQQE shaft seal is a Grundfos rubber bellows
seal with reduced silicon carbide/silicon carbide
seal faces and secondary seals of EPDM.
BQQE
The BQQE shaft seal is a Grundfos rubber bellows
seal with silicon carbide/silicon carbide seal faces
and secondary seals of EPDM.
Information on a selection of common pumped liquids
with recommended shaft seals is shown on page 19.

TP Series 300 pumps have the following features and


benefits:

Shaft seal specification


Unbalanced shaft seal

Version NU according to EN
12756

Shaft diameter

28, 38, 48 and 55 mm

Rubber bellows
Seal faces

EPDM
Carbon/silicon carbide
Silicon carbide/silicon carbide

Special shaft seals are available for partly conditioned


water or other liquids containing abrasive or
crystallising particles. See page 19.

Connections
TP, TPD Series 300 pumps are equipped with PN 16
flanges. All dimensions are according to ISO 7005-2 or
EN 1092-2.

24

Optimised hydraulics for high efficiency


- reduced power consumption.
High-efficiency motors
- TP pumps are fitted with high-efficiency motors.
High-efficiency motors offer reduced energy
consumption.
TP pumps are primarily fitted with motors that
meet the legislative requirements of the EuP IE3
grade. For further information, see Motor, pages
59 to 63.
Top-pull-out design
- easy dismantling in case of service.
In-line design
- contrary to end-suction pumps, in-line pumps
allow a straight pipework and thus often reduced
installation costs.
Motor-pump shaft with sleeve coupling
- stable and quiet operation.
- easy dismantling in case of service.
Hydraulically and mechanically balanced impeller
- The impeller is hydraulically and mechanically
balanced to increase the life of motor bearings
and shaft seal.
Pump housing and motor stool are electrocoated
to improve the corrosion resistance
- Electrocoating includes:
Alkaline cleaning
Pre-treatment with zinc phosphate coating
Cathodic electrocoating (epoxy)
Curing of paint film at 200-250 C.
For low-temperature applications at a high
humidity, Grundfos offers TP pumps with extra
surface treatment to avoid corrosion.
These pumps are available on request.

TP, TPD, TPE

TP Series 400 pumps

8. TP Series 400 pumps

Fig. 7

TM04 9587 4610

GR7539

Materials

Fig. 8

Sectional drawing of TP Series 400

Material specification

TP Series 400

TP Series 400, PN 10

Technical data
Flow rate:
Head:

PN
PN
PN
PN

Pos. Component

10
25
10
25

version:
version:
version:
version:

up
up
up
up

to
to
to
to

1230 m /h
1280 m3/h
55 m
235 m

Liquid temperature:
PN 10 version: -25 - +120 C
PN 25 version: 0-150 C*
* From +120 to +150 C, max. 23 bar
Max. operating pressure:
10 bar version: 10 bar
25 bar version: 25 bar
Direction of rotation: Clockwise

Pump housing

Impeller

Grundfos TP Series 400 pumps are single-stage,


close-coupled pumps with in-line suction and
discharge ports.
The pumps are equipped with a fan-cooled
asynchronous motor. Motor and pump shafts are
connected via a rigid flange coupling.
TP Series 400 pumps are available as single-head
(TP) models. All TP Series 400 pumps have flange
connection PN 10 or PN 25.
The pumps are equipped with an unbalanced
mechanical shaft seal.
The pumps are of the top-pull-out design, i.e. the
power head (motor, motor stool, pump head and
impeller) can be removed for maintenance or service
while the pump housing remains in the pipework.
The pump housing is provided with replaceable wear
rings to ensure high pump efficiency for life.
As radial and axial forces are absorbed by the fixed
bearing in the motor drive-end, the pump requires no
bearing.
TP Series 400 pumps are equipped with
high-efficiency motors.

EN/DIN
EN-JL1040

Ductile cast iron EN-GJS-400

EN-JL1030

Bronze

2.1096.01

Pump shaft

Stainless steel

1.4436

Coupling

Cast iron EN-GJL-250

EN-JL1040

Motor stool

Cast iron EN-GJL-250

EN-JL1040

Secondary seals

EPDM rubber

Rotating seal face

Carbon, metal-impregnated
Silicon carbide

Stationary seat

Silicon carbide

Wear rings

Bronze CuSn10

2.1093

TP Series 400, PN 25
Pos. Component
1

Construction

Material
Cast iron EN-GJL-250

Pump housing
Impeller

Material

EN/DIN

Ductile cast iron


EN-GJS-400-18 (A-LT)

EN-JS1020

Ductile cast iron EN-GJS-400

EN-JS1030

Bronze

2.1096.01

Pump shaft

Stainless steel

1.4436

Coupling

Cast iron EN-GJL-250

EN-JL1040

Motor stool

Cast iron EN-GJL-250

EN-JL1040

Secondary seals

EPDM rubber

Rotating seal face Carbon, resin-impregnated


Stationary seat

Tungsten carbide

25

TP, TPD, TPE

TP Series 400 pumps

Mechanical shaft seal

Features and benefits

For 10 bar versions, the following three types of


unbalanced mechanical shaft seals are available as
standard:
BAQE
The BAQE shaft seal is a Grundfos rubber bellows
seal with carbon/silicon carbide seal faces and
secondary seals of EPDM.
GQQE
The GQQE shaft seal is a Grundfos rubber bellows
seal with reduced silicon carbide/silicon carbide
seal faces and secondary seals of EPDM.
BQQE
The BQQE shaft seal is a Grundfos rubber bellows
seal with silicon carbide/silicon carbide seal faces
and secondary seals of EPDM.
For 25 bar versions, the following mechanical shaft
seal is available as standard:
DBUE
The DBUE shaft seal is a Grundfos balanced O-ring
seal with carbon/tungsten carbide seal faces and
secondary seals of EPDM.
Information on a selection of common pumped liquids
with recommended shaft seals is shown on page 19.
Special shaft seals are available for partly conditioned
water or other liquids containing abrasive or
crystallising particles. See page 19.

TP Series 400 pumps have the following features and


benefits:

Connections
TP Series 400 pumps are the only TP pumps with
suction and discharge ports of different diameters.
The suction port is one dimension larger than the
discharge port in order to obtain a low inlet velocity.
This reduces the risk of cavitation and noise.
TP Series 400 pumps have flanges according to ISO
7005-2 or EN 1092-2.

26

Optimised hydraulics for high efficiency


- reduced power consumption.
High-efficiency motors
- TP pumps are fitted with high-efficiency motors.
High-efficiency motors offer reduced energy
consumption.
TP pumps are primarily fitted with motors that
meet the legislative requirements of the EuP IE3
grade. For further information, see Motor, pages
59 to 63.
Top-pull-out design
- easy dismantling in case of service.
In-line design
- contrary to end-suction pumps, in-line pumps
allow a straight pipework and thus often reduced
installation costs.
Motor-pump shaft with flanged coupling
- stable and quiet operation
- easy dismantling in case of service.
Supported flange connection
- The pump housing has flange connections with
integrated feet in order to stabilise the pump.
Surface treatment
TP Series 400 pumps are given the following
surface treatment:
Pump type
TP Series 400

Electrocoating

Spray painting

Electrocoating includes:
Alkaline cleaning
Pre-treatment with zinc phosphate coating
Cathodic electrocoating (epoxy)
Curing of paint film at 200-250 C.
For low-temperature applications at a high
humidity, Grundfos offers TP pumps with extra
surface treatment to avoid corrosion.
These pumps are available on request.

TP, TPD, TPE

TPE Series 1000 pumps

9. TPE Series 1000 pumps

TM03 0503 0105

Applications

Fig. 9

TPE Series 1000 pumps have integrated speed control


for automatic adaptation of performance to current
conditions.
This ensures that the energy consumption is kept at a
minimum.
TPE pumps can operate at any duty point within the
range between 25 % and 100 % speed.

HH
[m]
[m]
100 %

TPE Series 1000

Flow rate:
Head:
Liquid temperature:
Max. operating pressure:
Motor sizes (three-phase):

Up to 340 m3/h
Up to 90 m
-25 - +140 C
16 bar
1.1 to 22 kW

Construction
TPE Series 1000 pumps are based on TP Series 100,
200 and 300 pumps.
The main difference between the TP and the TPE
Series 1000 pump range is the motor. The MGE motor
of TPE Series 1000 pumps a has built-in frequency
converter for continuous adjustment of the pressure to
the flow rate. TPE pumps with 2-pole motors below
3 kW and 4-pole motors below 1.5 kW are fitted with
permanent-magnet motors which have an efficiency
that exceeds the IE4 demands - including the energy
consumption of the integrated frequency converter
(compared to IE levels in IEC 60034-30-1 Ed. 1 (CD)).
TPE Series 1000 pumps are suitable for applications
where the pressure, temperature, flow rate or another
parameter is to be controlled on the basis of signals
from a sensor at some point in the system.
Note: TPE Series 1000 pumps are not fitted with a
sensor from factory.
For further information on construction and materials
of TPE Series 1000 pumps, see pages 21 to 24.

25 %

Q [m3h]

Q [m/h]

TM01 4916 1099

Technical data

Fig. 10 Duty range of TPE Series 1000 pumps

The 100 % curve corresponds to the curve of a pump


with a mains-operated motor.
Depending on the application, TPE Series 1000 pumps
offer energy savings, increased comfort or improved
processing.
The pumps can be fitted with sensor types meeting the
requirements mentioned in section 25. Accessories.

27

TP, TPD, TPE

TPE Series 1000 pumps

The charts below show possible control modes of TPE Series 1000 pumps in different applications.
System application

Select this control mode

In systems with relatively large pressure losses in the distribution pipes and in
air-conditioning and cooling systems.
Two-pipe heating systems with thermostatic valves and
very long distribution pipes
strongly throttled pipe balancing valves
differential-pressure regulators
large pressure losses in those parts of the system through which the total
quantity of water flows (for example boiler, heat exchanger and distribution
pipe up to the first branching).
Primary circuit pumps in systems with large pressure losses in the primary
circuit.
Air-conditioning systems with
heat exchangers (fan coils)
cooling ceilings
cooling surfaces.

Constant differential pressure (with


differential-pressure sensor located in
the system)

In systems with relatively small pressure losses in the distribution pipes.


Two-pipe heating systems with thermostatic valves and
dimensioned for natural circulation
small pressure losses in those parts of the system through which the total
quantity of water flows (for example boiler, heat exchanger and distribution
pipe up to the first branching), or
modified to a high differential temperature between flow pipe and return pipe
(for example district heating).
Underfloor heating systems with thermostatic valves.
One-pipe heating systems with thermostatic valves or pipe balancing valves.
Primary circuit pumps in systems with small pressure losses in the primary
circuit.

Constant differential pressure

Pump type

H
All

H
All

Q
Constant temperature

H
All

In systems with a fixed system characteristic.


Examples:
one-pipe heating systems
boiler shunts
systems with three-way valves
domestic hot-water circulation.

Q
Constant differential temperature

H
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole

Q
Constant curve
If an external controller is installed, the pump is able to change from one constant
curve to another, depending on the value of the external signal.
The pump can also be set to operate according to the max. or min. curve:
The max. curve mode can be used in periods in which a maximum flow is
required.
This operating mode is suitable e.g. for hot-water priority.
The min. curve mode can be used in periods in which a minimum flow is
required.

H
All

Q
Constant flow rate

H
In systems requiring a constant flow, independently of pressure drop.
Examples:
chillers for air-conditioning
heating surfaces
cooling surfaces.

All

Q set

28

System application

Select this control mode

TPE Series 1000 pumps

TP, TPD, TPE

Pump type

Constant level

H
In systems requiring a constant tank level, independently of the flow rate.
Examples:
process water tanks
boiler condensate tanks.

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole

Q
In systems with pumps operating in parallel.
The multi-pump function enables the control of single-head pumps connected in
parallel (two to four pumps) and twin-head pumps without the use of external
controllers. The pumps in a multi-pump system communicate with each other via
the wireless GENIair connection or the wired GENI connection.

"Assist" menu, "Multi-pump setup"

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole

Control options
Communication with TPE Series 1000 pumps is
possible via a central building management system,
remote control (Grundfos GO Remote) or control
panel.
The purpose of controlling a TPE Series 1000 pump is
to monitor and control the pressure, temperature, flow
rate and liquid level of the system.
For further information on control options of TPE
pumps, see page 55.

29

10

TP, TPD, TPE

Overview of functions

10. Overview of functions


E-pump type
Control panel

E-pump functions

TPE
Series 1000

TPE
Series 1000

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole

3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Setting via standard control panel


Setpoint
Start/stop
Max. curve
Min. curve
Alarm reset
Enable radio communication

Status readings via standard control panel


Stop

Setpoint
Operating indication
Fault indication
Operating mode: MIN, MAX, STOP

Setting via standard control panel


Setpoint
Start/stop
Max. curve
Min. curve
Alarm reset

Status readings via standard control panel


Setpoint
Operating indication
Fault indication

Operating mode: MIN, MAX, STOP

Settings via Grundfos GO Remote


Setpoint
Operating mode
Control mode
Date and time
Buttons on product
Controller
Operating range
Pump number
Radio communication
Sensor type
Analog input 1
Analog input 2

3)

Analog input 3

3)

Pt100/1000 input 1

3)

Pt100/1000 input 2

3)

Digital input 1
Digital input/output 3

3)

Digital input/output 4

3)

Analog output

3)

1)

Digital input 2

External setpoint function


Signal relay 1

Signal relay 2

Limit 1 exceeded
Limit 2 exceeded
Standstill heating

Motor bearing monitoring

2)

Service
Store settings
Recall settings
Undo
Pump name
Unit configuration

Available.
1)
Only 11-22 kW.
2) Lubricated, only 11-22 kW.
3)
Only available if an advanced functional module is fitted.

30

Overview of functions

10

TP, TPD, TPE

E-pump type
Control panel

E-pump functions

TPE
Series 1000

TPE
Series 1000

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole

3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Status readings via Grundfos GO Remote


Resulting setpoint
Actual controlled value
Motor speed (rpm, %)
Power consumption
Energy consumption
Acc. flow, specific energy
Operating hours
Pt100/1000 input 1

3)

Pt100/1000 input 2

3)

Analog output

3)

Analog input 1
Analog input 2
Analog input 3
Digital input 1
Digital input 2
Digital input/output 3
Digital input/output 4
Fitted modules

3)

3)

3)

Setting via GENIbus


Setpoint
Start/stop
Max. curve
Min. curve
Constant pressure, proportional pressure or constant curve

Setpoint
Operating indication

Pump status

Fault, Operation, Ready, Pump running, Bearing lubrication, Warning


(signal relay)

Limit exceeded 1 and 2 (signal relay)

Reading via GENIbus

Setting via external signal


Setpoint
Predefined setpoint
Start/stop
Min./max. curve via digital input
Alarm resetting

Reading via external signal

Optional functions

Optional functions with advanced functional module


Real-time clock
Analog output
Additional analog, digital and PT100/1000 inputs

Available.
Only 11-22 kW.
2)
Lubricated, only 11-22 kW.
3)
Only available if an advanced functional module is fitted.
1)

31

11

TP, TPD, TPE

User interfaces for TPE pumps

11. User interfaces for TPE pumps


Pump settings can be made by means of the following
user interfaces:
Control panels

Pos.

Remote controls

TPE Series
1000

Fitted as
standard

Option

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Light fields for indication of setpoint.

Changes the setpoint and reset of alarms and


warnings.

Enables radio communication with the


Grundfos GO Remote and other products of
the same type.

Makes the pump ready for operation/starts


and stops the pump.
Start:
If the button is pressed when the pump is
stopped, the pump will only start if no other
functions with higher priority have been
enabled.
Stop:
If the button is pressed when the pump is
running, the pump will always be stopped.
When the pump is stopped via this button, the
"Stop" text next to the button will illuminate.

Grundfos GO Remote.
See Grundfos GO Remote, page 35.
If the power supply to the pump is switched off, the
settings will be stored.

Control panel for TPE Series 1000 pumps,


0.12 - 2.2 kW, 2-pole, and 0.12 - 1.1 kW,
4-pole

Description
Grundfos Eye
Shows the operating status of the pump.
See page 51 for further information.

TPE Series 1000 pumps, 0.12 - 2.2 kW, 2-pole, and


0.12 - 1.1 kW, 4-pole. See page 32.
TPE Series 1000 pumps, 3-22 kW, 2-pole, and 1.5 18.5 kW, 4-pole. See page 34.

Pump variant

Symbol

Setpoint setting
Set the desired setpoint of the pump by pressing
or
. The light fields on the control panel will indicate
the setpoint set.
Pump in differential-pressure control mode

4
Stop

TM05 4848 3512

The following example applies to a pump in an


application where a pressure sensor gives feedback to
the pump. If the sensor is retrofitted to the pump, it
must be set up manually as the pump does not
automatically register a connected sensor.
Figure 12 shows that the light fields 5 and 6 are
activated, indicating a desired setpoint of 3 metres with
a sensor measuring range from 0 to 6 metres.
The setting range is equal to the sensor measuring
range.
m
6

Fig. 11 Standard control panel

0
Fig. 12 Setpoint set to 3 metres, differential-pressure
control

32

TM05 4894 3512

11

TP, TPD, TPE

In constant-curve control mode, the pump performance


will be between the max. and min. curve of the pump.
See fig. 13.

Setting to min. curve:


continuously to change over to the min.
Press
curve of the pump (bottom light field flashes).
When the bottom light field is on, press
for
3 seconds until the light field starts flashing.
To change back, press
continuously until the
desired setpoint is indicated.
Example: Pump set to min. curve.
Figure 15 shows that the bottom light field is flashing,
indicating min. curve.

User interfaces for TPE pumps

Pump in constant-curve control mode

Fig. 13 Pump in constant-curve control mode

Setting to max. curve:


continuously to change over to the max.
Press
curve of the pump (top light field flashes). When the
top light field is on, press
for 3 seconds until the
light field starts flashing.
continuously until the
To change back, press
desired setpoint is indicated.
Example: Pump set to max. curve.
Figure 14 shows that the top light field is flashing,
indicating max. curve.
H

TM05 4897 2812

TM05 4895 2812

Fig. 15 Min. curve duty

Start/stop of pump
Start the pump by pressing
or by continuously
pressing
until the desired setpoint is indicated.
Stop the pump by pressing
. When the pump is
stopped, the "Stop" text next to the button will
illuminate. The pump can also be stopped by
until none of the light fields
continuously pressing
are on.
If the pump has been stopped by pressing
, it can
only be released for operation by pressing
again.
If the pump has been stopped by pressing
, it can
only be restarted by pressing
.
The pump can also be stopped with the Grundfos GO
Remote or via a digital input set to "External stop".

Q
Fig. 14 Max. curve duty

TM05 4896 2812

Resetting of fault indications


A fault indication can be reset in one of the following
ways:
Via the digital input if it has been set to "Alarm
resetting".
on the pump. This will not
Briefly press
or
change the setting of the pump.
A fault indication cannot be reset by pressing
or
if the buttons have been locked.
Switch off the power supply until the indicator lights
are off.
Switch the external start/stop input off and then on
again.
With the Grundfos GO Remote.

33

11

TP, TPD, TPE

Pump variant
TPE Series
1000

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Fitted as
standard

Option

The pump control panel (fig. 16) incorporates the


following buttons and indicator lights:
buttons,
and , for setpoint setting
light fields, yellow, for setpoint indication
Indicator lights, green (operation) and red (fault).

TM00 7746 1304

User interfaces for TPE pumps

Control panel for TPE Series 1000 pumps,


3-22 kW, 2-pole, and 1.5 - 18.5 kW, 4-pole

Fig. 18 Pump performance setting, "Constant curve"


control mode
Buttons

Setting to max. curve duty

Light fields

TM00 7345 1304

Fig. 16 Control panel for TPE Series 1000 pumps,


3-22 kW, 2-pole, and 1.5 - 18.5 kW, 4-pole

Setpoint setting
Note: The setpoint can only be set when the operating
mode is "Normal".
Set the desired setpoint by pressing
or .
The light fields on the control panel will indicate the
setpoint set.
"Differential-pressure control" mode
Example

TM03 5845 4006

Figure 17 shows that light fields 5 and 6 are activated,


indicating a desired setpoint of 3.4 m. The sensor
measuring range is 0 to 6 m. The setting range is equal
to the sensor measuring range (see sensor
nameplate).

Fig. 17 Setpoint set to 3.4 m (differential-pressure control)

"Constant curve" control mode


Example
In this control mode, the pump performance is set
within the range from min. to max. curve. See fig. 18.

34

Q
Fig. 19 Max. curve duty

Setting to min. curve duty


Press
continuously to change to the min. curve of
the pump (bottom light field flashes). See fig. 20.
To change back, press
continuously until the
desired setpoint is indicated.
H

TM00 7346 1304

Indicator lights

TM05 8590 2613

Press
continuously to change to the max. curve of
the pump (top light field flashes). See fig. 19.
To change back, press
continuously until the
desired setpoint is indicated.

Fig. 20 Min. curve duty

Start/stop of pump
Start the pump by continuously pressing
until the
desired setpoint is indicated.
Stop the pump by continuously pressing
until none
of the light fields are activated and the green indicator
light flashes.

Dashboard

+
2
Status

+
3

Resulting setpoint
Actual setpoint
External setpoint
Actual controlled value
Sensor value
Motor speed (rpm %)
Power consumption
Energy consumption
Acc. flow, specific energy
Operating hours

TM05 5383 4312

Fig. 21 Grundfos GO Remote communicating with the


pump via radio or infrared light
Pos.
1

Description
Grundfos MI 201:
Consists of an Apple iPod touch 4G and a Grundfos cover.

When the Grundfos GO Remote communicates with


the pump, the indicator light in the middle of the
Grundfos Eye will flash green. See Grundfos Eye,
page 51.
Communication must be established using one of
these communication types:
radio communication
infrared communication.

1)

1)

1)

Digital input 2
Digital input/output 3
Digital input/output 4
Fitted modules
Controlled from
1)

Pt100/1000 input 1

Digital input 1

Communication

Pt100/1000 input 2

Analog input 3

Grundfos MI 301:
Separate module enabling radio or infrared communication.
The module can be used in conjunction with an Android or
iOS-based Smartphone with Bluetooth connection.

Analog input 1
Analog input 2

Grundfos MI 204:
Add-on module which can be used in conjunction with an
Apple iPod touch 5G or iPhone 5.

Analog output

Grundfos MI 202:
Add-on module which can be used in conjunction with an
Apple iPod touch 4G, iPhone 4G or 4GS.

TPE Series 1000


3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Main menus

TPE Series 1000


3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

The pump is designed for wireless radio or infrared


communication with the Grundfos GO Remote.
The Grundfos GO Remote enables setting of functions
and gives access to status overviews, technical
product information and actual operating parameters.
The Grundfos GO Remote offers three different mobile
interfaces (MI). See fig. 21.

TPE Series 1000


0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole

Menu overview for Grundfos GO Remote

TPE Series 1000


0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole

Grundfos GO Remote

User interfaces for TPE pumps

11

TP, TPD, TPE

1)

1)

1)

Only available if an advanced functional module is fitted.

Radio communication
Radio communication can take place at distances up
to 30 metres. It is necessary to enable communication
by pressing
or
on the pump control panel.
Infrared communication
When communicating via infrared light, the Grundfos
GO Remote must be pointed at the pump control
panel.

35

11

Date and time


Buttons on product
Controller
Operating range
Ramps
Pump number
Radio communication
Sensor type
Analog input 1
Analog input 2

1)

1)

Pt100/1000 input 2

1)

Section

Page

Setpoint
Operating mode
Control mode

37
37
37

Controller settings
Operating range
Ramps
Pump number

44
45
49
49

Sensor type

41

Analog inputs

41

Pt100/1000 inputs

41

Digital inputs

41

Pt100/1000 input 1

Digital input/output 3

1)

Digital input/output 4

1)

Digital inputs/outputs

42

Predefined setpoint

1)

Predefined setpoints

48

Analog output

1)

Analog output

43

External setpoint influence

45

Signal relay 2

2)

Relay outputs

43

Limit 1 exceeded
Limit 2 exceeded
Standstill heating
Motor bearing monitoring
Service
Store settings
Recall settings
Undo
Pump name
Unit configuration

Limit-exceeded function

48

Alarms and warnings

Alarm log
Warning log
"Reset alarm" button

TPE Series 1000


3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

External setpoint function


Signal relay 1

Assisted pump setup


Assisted fault advice
Multi-pump setup

TPE Series 1000


3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

TPE Series 1000


0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole

Only available if an advanced functional module is fitted.


Only 11-22 kW.

Assist

36

1)

Digital input 1

2)

Analog input 3

Digital input 2

1)

TPE Series 1000


3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Setpoint
Operating mode
Control mode

TPE Series 1000


0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole

User interfaces for TPE pumps

Settings

TPE Series 1000


0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole

TP, TPD, TPE

Section

Multi-pump setup

Page

49

11

TP, TPD, TPE

Description of selected functions


Setpoint
The setpoint for all control modes can be set in this
submenu when the desired control mode has been
selected. See Control mode, page 37.

Operating mode
Possible operating modes:
Normal
The pump runs according to the selected control
mode.
Stop
The pump stops.
Min.
The min. curve mode can be used in periods in
which a minimum flow is required.
Max.
The max. curve mode can be used in periods in
which a maximum flow is required.
This operating mode is suitable e.g. for hot-water
priority.
Manual
The pump is operating at a manually set speed.
See Set manual speed, page 37.
The pump can be set to operate according to the max.
or min. curve. See fig. 22.

User interfaces for TPE pumps

Control mode
Possible control modes:
Const. pressure (constant pressure)
Const. temp. (constant temperature)
Con. diff. press. (constant differential pressure)
Con. diff. temp. (constant differential temperature)
Const. flow rate (constant flow rate)
Const. level (constant level)
Const. other val. (constant other value)
Const. curve (constant curve).
The setpoint for all control modes, except AUTOADAPT
and FLOWADAPT, can be changed in the "Setpoint"
submenu under "Settings" when the desired control
mode has been selected.
Constant pressure
Pump variant
TPE Series 1000

Constant pressure
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

The pump maintains a constant discharge pressure,


independently of the flow rate. See fig. 23.
H

Max.

Min.

TM00 5547 0995

Fig. 22 Max. and min. curves

Set manual speed

TM05 7901 1613

Fig. 23 Constant pressure

This control mode requires an external


differential-pressure sensor as shown in the examples
below:
Examples
One external differential-pressure sensor.

The pump speed can be set in %. When the operating


mode has been set to "Manual", the pump will run at
the set speed.
p
p

Fig. 24 Constant pressure

37

11

TP, TPD, TPE

User interfaces for TPE pumps

Constant temperature

Constant differential pressure

Pump variant
TPE Series 1000

Constant temperature
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Constant differential
pressure

Pump variant

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

TPE Series 1000

This control mode ensures a constant temperature.


Constant temperature is a comfort control mode that
can be used in domestic hot-water systems to control
the flow to maintain a fixed temperature in the system.
See fig. 25. When this control mode is used, no
balancing valves must be installed in the system.

The pump maintains a constant differential pressure,


independently of the flow in the system. See fig. 27.
This control mode is primarily suitable for systems with
relatively small pressure losses.
H

Q
Fig. 25 Constant temperature

Q
Fig. 27 Constant differential pressure

This control mode requires an external temperature


sensor as shown in the examples below:

This control mode requires an external


differential-pressure sensor or two external pressure
sensors as shown in the examples below.

Examples
One external temperature sensor.

Examples
One external differential-pressure sensor.

t
p
p

Fig. 26 Constant temperature

Two external pressure sensors.


(Applies only to TPE pumps with motor sizes from
0.12 to 2.2 kW.)
p

p
p

p
p

Fig. 28 Constant differential pressure

38

TM05 7901 1613

TM05 7900 1613

11

TP, TPD, TPE

Constant differential
temperature

Pump variant

TPE Series 1000

Constant flow rate

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Pump variant
TPE Series 1000

The pump maintains a constant differential


temperature in the system and the pump performance
is controlled according to this. See fig. 29.

User interfaces for TPE pumps

Constant differential temperature

Constant flow rate


0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

The pump maintains a constant flow in the system,


independently of the head. See fig. 31.
H

Q
Fig. 29 Constant differential temperature

This control mode requires either two temperature


sensors or one external differential-temperature
sensor as shown in the examples below:
Examples
Two external temperature sensors.
(Applies only to TPE pumps with motor sizes from
0.12 to 2.2 kW.)
t

Fig. 31 Constant flow rate

This control mode requires an external flow sensor as


shown below:
Example
One external flow sensor.
Q

Fig. 32 Constant flow rate

Constant level
Pump variant

t
t

One external differential-temperature sensor.

Q set

TM05 7955 1713

TM05 7954 1713

TPE Series 1000

Constant level
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

The pump maintains a constant level, independently of


the flow rate. See fig. 33.
t
H

TM05 7941 1613

Fig. 30 Constant differential temperature

Fig. 33 Constant level

39

11

TP, TPD, TPE

User interfaces for TPE pumps

This control mode requires an external level sensor.


The pump can control the level in a tank in two ways:
as an emptying function where the pump draws the
liquid from the tank
as a filling function where the pump pumps the
liquid into the tank.
See fig. 34.
The type of level control function depends on the
setting of the built-in controller. See Controller settings,
page 44.

Constant curve
Pump variant
TPE Series 1000

Constant curve
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

The pump can be set to operate according to a


constant curve. See fig. 35.
The desired speed can be set in % of maximum speed
in the range from 25 to 100 %.

Examples
One external level sensor
emptying function.

One external level sensor


filling function.

Fig. 35 Constant curve

Note: Depending on the system characteristics and


the duty point, the 100 % setting may be slightly
smaller than the pumps actual max. curve, even
though the display shows 100 %. This is due to power
and pressure limitations built into the pump.
The deviation varies according to pump type and
pressure loss in the pipes.

Fig. 34 Constant level

Constant other value


Pump variant
TPE Series 1000

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

TM05 7957 1713

Constant other value

H [%]

100 %
Limited max. curve

80 %

Q [m3/h]

Fig. 36 Power and pressure limitations influencing the


max. curve

40

TM05 7913 1613

Any other value is kept constant.

11

TP, TPD, TPE

Electrical signal

Pump variant
TPE Series 1000

Sensor type
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Set the min. value of the connected sensor.

The setting of the sensor is only relevant in the case of


controlled operation.
Select among the following values:
Sensor output signal
0-10 V
0-20 mA
4-20 mA.
Unit of measurement of sensor:
bar, mbar, m, kPa, psi, ft, m/h, m/s, l/s, gpm, C,
F, %.
Sensor measuring range.

Analog inputs

TPE Series 1000

Select signal type (0.5 - 3.5 V, 0-5 V, 0-10 V, 0-20 mA


or 4-20 mA).
Sensor range, min. value

Sensor range, max. value


Set the max. value of the connected sensor.

Pt100/1000 inputs
Pump variant
TPE Series 1000

Pt100/1000 inputs
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Analog inputs
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Available inputs depending on the functional module


fitted in the pump:
Function (terminal)
Analog input 1, setup (4)
Analog input 2, setup (7)
Analog input 3, setup (14)

FM 200
(standard)

FM 300
(advanced)

To set up an analog input, make the settings below.


Function
The analog inputs can be set to these functions:
Not active
Feedback sensor
Ext. setpoint influence
See Setpoint influence, page 45.
Other function.
Measured parameter
Select one of the parameters, i.e. the parameter to be
measured in the system by the sensor connected to
the actual analog input.

FM 200
(standard)

FM 300
(advanced)

Pt100/1000 input 1, setup (17 and 18)


Pt100/1000 input 2, setup (18 and 19)

Function
The Pt100/1000 inputs can be set to these functions:
Not active
Feedback sensor
Ext. setpoint influence
See Setpoint influence, page 45.
Other function.
Measured parameter
Select one of the parameters, i.e. the parameter to be
measured in the system.

Digital inputs
Pump variant
TPE Series 1000

Digital inputs
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Motors from 0.12 - 2.2 kW, 2-pole, and 0.12 - 1.1 kW,
4-pole
Available inputs depending on the functional module
fitted in the pump:
Function (terminal)

Unit

Available inputs depending on the functional module


fitted in the pump:
Function (terminal)

Pump variant

FM 200
(standard)

FM 300
(advanced)

Available measuring units:

Digital input 1, setup (2 and 6)


Digital input 2, setup (1 and 9)

Parameter

Possible units

To set up a digital input, make the settings below.

Pressure

bar, m, kPa, psi, ft

Pump flow

m3/h, l/s, yd3/h, gpm


C, F
%

Liquid temperature
Other parameter

User interfaces for TPE pumps

Sensor type

41

11

TP, TPD, TPE

User interfaces for TPE pumps

Function
Select one of these functions:
Not active
When set to "Not active", the input has no function.
External stop
When the input is deactivated (open circuit), the
pump will stop.
Min. (min. speed)
When the input is activated, the pump will run at the
set min. speed.
Max. (max. speed)
When the input is activated, the pump will run at the
set max. speed.
External fault
When the input is activated, a timer will be started.
If the input is activated for more than 5 seconds, the
pump will be stopped and a fault will be indicated.
Alarm resetting
When the input is activated, a possible fault
indication will be reset.
Dry running
When this function has been selected, lack of inlet
pressure or water shortage can be detected.
When lack of inlet pressure or water shortage
(dry running) is detected, the pump will be stopped.
The pump cannot restart as long as the input is
activated.
This requires the use of an accessory, such as:
a pressure switch installed on the suction side of
the pump
a float switch installed on the suction side of the
pump.
Accumulated flow
This function is only available for TPE Series 1000
pumps with motor sizes from 0.12 - 2.2 kW, 2-pole,
and 0.12 - 1.1 kW, 4-pole.
When this function has been selected, the
accumulated flow can be registered. This requires
the use of a flowmeter which can give a feedback
signal as a pulse per defined flow of water.
See Pulse flowmeter setup, page 48.
Predefined setpoint digit 1 (applies only to digital
input 2)
When digital inputs are set to predefined setpoint,
the pump will operate according to a setpoint based
on the combination of the activated digital inputs.
See Predefined setpoints, page 48.

Motors from 3-22 kW, 2-pole, and 1.5 - 18.5 kW,


4-pole
The digital input of the pump can be set to different
functions. Select one of the following functions:
Min. (min. curve)
Max. (max. curve).
The selected function is activated by closing the
contact between terminals 1 and 9.
Min.:
When the input is activated, the pump will operate
according to the min. curve.
Max.:
When the input is activated, the pump will operate
according to the max. curve.

Digital inputs/outputs
Pump variant
TPE Series 1000

Digital inputs/outputs
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Available inputs/outputs depending on the functional


module fitted in the pump:
Function (terminal)
Digital input/output 3, setup (10 and 16)
Digital input/output 4, setup (11 and 18)

FM 200
(standard)

FM 300
(advanced)

To set up a digital input/output, make the settings


below.
Mode
The digital inputs/outputs 3 and 4 can be set to act as
digital inputs or digital outputs:
Function
The digital inputs/outputs 3 and 4 can be set to these
functions:
Possible functions, digital input/output 3
Function if input

Function if output

Not active
External stop
Min.
Max.
External fault
Alarm resetting
Dry running
Accumulated flow*
Predefined setpoint digit 2

This function is only available for TPE Series 1000 pumps with
motor sizes from 0.12 - 2.2 kW, 2-pole, and 0.12 - 1.1 kW, 4-pole.

Not active
Ready
Alarm
Operation
Pump running
Warning
Limit 1 exceeded*
Limit 2 exceeded*

Possible functions, digital input/output 4

42

Function if input

Function if output

Not active
External stop
Min.
Max.
External fault
Alarm resetting
Dry running
Accumulated flow*
Predefined setpoint digit 3

This function is only available for TPE Series 1000 pumps with
motor sizes from 0.12 - 2.2 kW, 2-pole, and 0.12 - 1.1 kW, 4-pole.

Not active
Ready
Alarm
Operation
Pump running
Warning
Limit 1 exceeded*
Limit 2 exceeded*

11

TP, TPD, TPE

Analog output
Relay outputs

Pump variant

TPE Series 1000

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole
3 - 7.5 kW, 2-pole
1.5 - 7.5 kW, 4-pole
11 - 22 kW, 2-pole
11 - 18.5 kW, 4-pole

Signal
relay 1

Signal
relay 2

The pump incorporates two signal relays for


potential-free signalling.
The signal relays can be configured to be activated by
one of the following incidents:
Ready
Operation
Alarm
Warning
Limit 2 exceeded*
Limit 1 exceeded*
Pump running
Relubricate (11-22 kW)
Control of external fan*
Not active.
* This function is only available for TPE Series 1000
pumps with motor sizes from 0.12 - 2.2 kW, 2-pole,
and 0.12 - 1.1 kW, 4-pole.

Pump variant
TPE Series 1000

User interfaces for TPE pumps

Relay outputs

Analog output
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Whether the analog output is available or not depends


on the functional module fitted in the pump:
Function (terminal)
Analog output

FM 200
(standard)

FM 300
(advanced)

To set up an analog output, make the settings below.


Output signal
0-10 V
0-20 mA
4-20 mA.
Function of analog output

Actual speed
Actual value
Resulting setpoint
Motor load
Motor current
Limit 1 exceeded*
Limit 2 exceeded*
Flow rate.
This function is only available for TPE Series 1000
pumps with motor sizes from 0.12 - 2.2 kW, 2-pole,
and 0.12 - 1.1 kW, 4-pole.

43

11

TP, TPD, TPE

User interfaces for TPE pumps

Controller settings

Kp

Pump variant

Temperature control

Controller settings
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

TPE Series 1000

Heating
system 1)

Cooling
system 2)

Ti

0.5

-0.5

10 + 5L2

0.5

-0.5

30 + 5L2

The pumps have a factory default setting for gain (Kp)


and integral time (Ti).
However, if the factory setting is not the optimum
setting, the gain and the integral time can be changed:
Set the gain (Kp) within the range from 0.1 to 20.
Set the integral-action time (Ti) within the range
from 0.1 to 3600 s.
If 3600 s is selected, the controller will function as a
P controller.
Furthermore, the controller can be set to inverse
control. This means that if the setpoint is increased,
the speed will be reduced. In the case of inverse
control, the gain (Kp) must be set within the range from
-0.1 to -20.

t
L2
L2
t

1)
2)

In heating systems, an increase in pump performance will result in


a rise in temperature at the sensor.
In cooling systems, an increase in pump performance will result in
a drop in temperature at the sensor.

L2 = Distance [m] between heat exchanger and


sensor.
Differential-temperature control

Guidelines for setting of PI controller

Kp

Ti

-0.5

10 + 5L2

The tables below show the recommended controller


settings:
t

Differential-pressure control

Kp

Ti
L2

t
p

0.5

0.5

L2

L2 = Distance [m] between heat exchanger and


sensor.

L1

Flow control

Kp

Ti

0.5

0.5

Kp

Ti

0.5

0.5

0.1

0.5

Kp

Ti

-2.5

100

2.5

100

S
0.5

L1

L1 < 5 m: 0.5
L1 > 5 m: 3
L1 > 10 m: 5

Constant-pressure control

L1 = Distance [m] between pump and sensor.


p

Level control
L

44

General rules of thumb

Setpoint influence

If the controller reacts too slowly, increase Kp.


If the controller is hunting or unstable, dampen the
system by reducing K p or increasing Ti.

External setpoint influence

TPE Series 1000


Pump variant
TPE Series 1000

Operating range
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

67 %

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Motors from 0.12 - 2.2 kW, 2-pole, and 0.12 - 1.1 kW,
4-pole

Set the operating range as follows:


Set the min. speed within the range from fixed min.
speed to user-set max. speed.
Set the max. speed within the range from user-set
min. speed to fixed max. speed.
The range between the user-set min. and max. speeds
is the operating range. See fig. 37.
Note: Speeds below 25 % may result in noise from the
shaft seal.
100 %

External setpoint
influence

Pump variant

Operating range

User interfaces for TPE pumps

11

TP, TPD, TPE

Max. speed (fixed)


User-set max. speed

It is possible to influence the setpoint by an external


signal, either via one of the analog inputs or, if an
advanced functional module is fitted, via one of the
Pt100/1000 inputs.
Note: Before the "Digital inputs" can be enabled, one
of the analog inputs or Pt100/1000 inputs must be set
to "External setpoint function".
See Analog inputs, page 41, and Pt100/1000 inputs,
page 41.
If more than one input has been set up for setpoint
influence, the function will select the analog input with
the lowest number, for example "Analog input 2", and
ignore the other inputs, for example "Analog input 3" or
"Pt100/1000 input 1".
Motors from 3-22 kW, 2-pole, and 1.5 - 18.5 kW,
4-pole

24 %

User-set min. speed

12 %

Min. speed (fixed)

0%

Fig. 37 Example of min. and max. settings

TM00 6785 5095

Operating range

The input for external setpoint signal can be set to


different signal types. Select one of the following
types:
0-10 V
0-20 mA
4-20 mA
Not active.
If one of the signal types is selected, the actual
setpoint is influenced by the signal connected to the
external setpoint input.

45

11

TP, TPD, TPE

See fig. 38.


At a lower sensor value of 0 bar, a set setpoint of 2 bar
and an external setpoint of 60 %, the actual setpoint is
0.60 x (2 - 0) + 0 = 1.2 bar.
Actual setpoint = actual input signal x (setpoint - lower
value) + lower value.

Setpoint influence [%]

Setpoint

Actual
setpoint

1.2

Lower value

100

100

0
0

Actual input
External
100 setpoint
signal
signal [%]

Fig. 38 Example of setpoint influence

Pump type

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole

3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

TPE Series 1000

Not active
Linear function
Linear with Stop
Linear with Min.
Inverse function
Inverse with Stop
Inverse with Min.
Influence table
Influence table with Stop at Min.
Influence table with Stop at Max.

20

40

60

80

100

External input
[%]

Fig. 39 Linear function

The table below gives an overview of the types of


setpoint influence and the availability depending on
pump type.

Type of setpoint influence

TM05 6280 4612

Upper value

These functions can be selected:


Not active
When set to "Not active", the setpoint will not be
influenced by any external function.
Linear function
The setpoint is influenced linearly from 0 to 100 %.
See fig. 39.
Setpoint influence [%]

[bar]

TM05 6279 4612

User interfaces for TPE pumps

Example of external setpoint influence

"Linear with Stop" and "Linear with Min."


Linear with Stop
In the input signal range from 20 to 100 %, the
setpoint is influenced linearly.
If the input signal is below 10 %, the pump will
change to "Stop" operating mode.
If the input signal is increased above 15 %, the
operating mode will be changed back to "Normal".
See fig. 40.
Linear with Min.
In the input signal range from 20 to 100 %, the
setpoint is influenced linearly.
If the input signal is below 10 %, the pump will
change to "Min." operating mode.
If the input signal is increased above 15 %, the
operating mode will be changed back to "Normal".
See fig. 40.
Setpoint influence [%]

100

20

40

60

80

100

External
input [%]

Normal

Min. or
Stop

Fig. 40 "Linear with Stop" and "Linear with Min."

46

TM05 6281 4612

11

TP, TPD, TPE

Setpoint influence [%]

Influence table
The setpoint is influenced by a curve made out of
two to eight points. There will be a straight line
between the points and a horizontal line before the
first point and after the last point.

User interfaces for TPE pumps

Inverse function
The setpoint is influenced inversely from 0 to 100 %.
See fig. 41.

Setpoint influence [%]

100

20

40

60

100 External input [%]

80

Fig. 41 Inverse function

20

"Inverse with Stop" and "Inverse with Min."


Inverse with Stop
In the input signal range from 0 to 80 %, the
setpoint is influenced inversely.
If the input signal is above 90 %, the pump will
change to "Stop" operating mode.
If the input signal is reduced below 85 %, the
operating mode will be changed back to "Normal".
See fig. 42.
Inverse with Min.
In the input signal range from 0 to 80 %, the
setpoint is influenced inversely.
If the input signal is above 90 %, the pump will
change to "Min." operating mode.
If the input signal is reduced below 85 %, the
operating mode will be changed back to "Normal"
See fig. 42.

40

60

80

100 External input [%]

TM05 6284 4612

TM05 6283 4612

100

Fig. 43 Influence table

Influence table with Stop at Min.


See description of influence table graphics above.
If the input signal is below 10 %, the pump will
change to "Stop" operating mode.
If the input signal is increased above 15 %, the
operating mode will be changed back to "Normal".
See fig. 44.
Setpoint influence [%]

100

Setpoint influence [%]

20

40

60

80

100

Normal

Min. or
Stop

External
input [%]
TM05 6285 4612

0
100

Fig. 44 Influence table with Stop at Min.

0
40

60

80

100

External
input [%]

Normal
Min. or
Stop

TM05 6283 4612

20

Fig. 42 "Inverse with Stop" and "Inverse with Min."

47

11

TP, TPD, TPE

User interfaces for TPE pumps

Monitoring functions

Influence table with Stop at Max.


See description of influence table graphics above.
If the input signal is above 90 %, the pump will
change to "Min." operating mode.
If the input signal is reduced below 85 %, the
operating mode will be changed back to "Normal".
See fig. 45.

Limit-exceeded function

TPE Series 1000

Setpoint influence [%]

100

0
40

60

80

100 External
input [%]
TM05 6286 4612

20
Normal
Min. or
Stop

Fig. 45 Influence table with Stop at Max.

Predefined setpoints
Note: Only available if an advanced functional module
is fitted.
Pump variant

Predefined setpoints
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

TPE Series 1000

Seven predefined setpoints can be set and activated


by combining the input signals to digital inputs 2, 3 and
4 as shown in the table below.

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

0
1
0
1
0
1
0
1

0
0
1
1
0
0
1
1

0
0
0
0
1
1
1
1

Pulse flowmeter setup

TPE Series 1000


1
2
3
4
5
6
7

Special functions

Setpoint
Normal setpoint
Predefined setpoint
Predefined setpoint
Predefined setpoint
Predefined setpoint
Predefined setpoint
Predefined setpoint
Predefined setpoint

This function can monitor set limits of analog values.


It will react if the values exceed the limits. Each limit
can be set as a maximum or minimum value. For each
of the monitored values, a warning limit and an alarm
limit must be defined.
The function makes it possible to monitor two different
locations in a pump system at the same time, for
instance the pressure at a consumer and the pump
discharge pressure. This ensures that the discharge
pressure does not reach a critical value.
If the value exceeds the warning limit, a warning is
given. If the value exceeds the alarm limit, the pumps
will be stopped.
A delay can be set between the detection of an
exceeded limit and the activation of a warning or an
alarm. A delay can also be set for resetting a warning
or an alarm.
A warning can be reset automatically or manually.
It is possible to set whether the system is to restart
automatically after an alarm, or if the alarm must be
reset manually. Restarting can be delayed by an
adjustable time. It is also possible to set a start-up
delay ensuring that the system reaches a steady state
before the function becomes active.

Pulse flowmeter
setup

Pump variant

Digital inputs

48

Limit-exceeded
function

Pump variant

0.12 - 2.2 kW, 2-pole


0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

An external pulse flowmeter can be connected to one


of the digital inputs in order to register the actual and
accumulated flows. Based on this, the specific energy
[kWh/m3] can also be calculated.
To enable a pulse flowmeter, one of the digital-input
functions must be set to "Accumulated flow" and the
pumped volume per pulse must be set. See Digital
inputs, page 41.

11

TP, TPD, TPE

Pump variant
TPE Series 1000

Pump number

Ramps
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Pump variant

TPE Series 1000

The setting of ramps is only relevant in the case of


constant-curve operation.
The ramps determine how quickly the motor can
accelerate and decelerate, respectively, during
start/stop or setpoint changes.
The following can be set:
acceleration time, 0.1 to 300 s
deceleration time, 0.1 to 300 s.
The times apply to the acceleration from stop to rated
speed and the deceleration from rated speed to stop,
respectively.
At short deceleration times, the deceleration of the
motor may depend on load and inertia as there is no
possibility of actively braking the motor.
If the power supply is switched off, the deceleration of
the motor will only depend on load and inertia.

Pump number
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Language
Pump variant
TPE Series 1000

Language
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

Multi-pump setup
Pump variant

Minimum

Ramp-up

Ramp-down

Fig. 46 Ramp-up and ramp-down

TM03 9439 0908

TPE Series 1000

Final ramp

A number of languages is available.


Measuring units are automatically changed according
to the selected language.

Rated

Initial ramp

General settings

Assist

Maximum

A unique number can be allocated to the pump.


This makes it possible to distinguish between pumps in
connection with bus communication.

Speed

Time

User interfaces for TPE pumps

Communication

Ramps

Multi-pump setup
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole
3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

The multi-pump function enables the control of


single-head pumps connected in parallel without the
use of external controllers. The pumps in a multi-pump
system communicate with each other via the wireless
GENIair connection or the wired GENI connection.
A multi-pump system is set up via a selected pump, i.e.
the master pump (first selected pump). All Grundfos
pumps with a wireless GENIair connection can be
connected to the multi-pump system.
The multi-pump functions are described in the
following sections.

49

11

TP, TPD, TPE

User interfaces for TPE pumps

Alternating operation
Only one pump is operating at a time.
The change from one pump to to the other depends on
time or energy. If a pump fails, the other pump will take
over automatically.
Pump system:
Two single-head pumps connected in parallel.
The pumps must be of the same type and size.
Each pump requires a non-return valve in series with
the pump.
Back-up operation
One pump is operating continuously. The back-up
pump is operated at intervals to prevent seizing up.
If the duty pump stops due to a fault, the back-up
pump will start automatically.
Pump system:
Two single-head pumps connected in parallel.
The pumps must be of the same type and size.
Each pump requires a non-return valve in series with
the pump.
Cascade operation
Cascade operation ensures that the pump
performance is automatically adapted to the
consumption by switching pumps on or off. The system
thus runs as energy-efficiently as possible with a
constant pressure and a limited number of pumps.
All pumps in operation will run at equal speed.
Pump changeover is automatic and depends on
energy, operating hours and faults, if any.
Pump system:
Two to four single-head pumps connected in
parallel.
The pumps must be of the same type and size.
Each pump requires a non-return valve in series
with the pump.
The control mode must be set to "Const. pressure",
"Const. diff. pressure" or "Const. curve".

50

11

TP, TPD, TPE

User interfaces for TPE pumps

Grundfos Eye
The operating condition of the motor is indicated by the
Grundfos Eye on the control panel. See fig. 47, pos. A.

TM05 5993 4312

Fig. 47 Grundfos Eye


Grundfos Eye

Indication

Description

No lights on.

Power off.
Motor not running.

Two opposite green indicator lights rotating in the


direction of rotation of the motor when seen from
the non-drive end.

Power on.
Motor running.

Two opposite green indicator lights permanently on.

Power on.
Motor not running.

One yellow indicator light rotating in the direction of


Warning.
rotation of the motor when seen from the non-drive
Motor running.
end.

One yellow indicator light permanently on.

Warning.
Motor stopped.

Two opposite red indicator lights flashing


simultaneously.

Alarm.
Motor stopped.

The green indicator light in the middle flashing


quickly four times.

Remote control with the Grundfos GO Remote via


radio.
The motor is trying to communicate with the
Grundfos GO Remote. The motor in question is
highlighted in the Grundfos GO Remote display to
inform the user of the location of the motor.

The green indicator light in the middle flashing


continuously.

When the motor in question is selected in the


Grundfos GO Remote menu, the green indicator
light in the middle will flash continuously. Press
on the motor control panel to allow remote control
and data exchange via the Grundfos GO Remote.

The green indicator light in the middle permanently


Remote control with the Grundfos GO Remote via
on.
radio.
The motor is communicating with the Grundfos GO
Remote via radio connection.
The green indicator light in the middle flashing
quickly while the Grundfos Go Remote is
exchanging data with the motor. This will take a few Remote control with the Grundfos GO Remote via
infrared light.
seconds.
The motor is receiving data from the Grundfos GO
Remote via infrared communication.

51

11

TP, TPD, TPE

User interfaces for TPE pumps

Indicator lights and signal relays


The following applies to the pumps below:
TPE Series 1000 pumps with the following motor sizes:
2.2 kW, 2-pole
1.1 kW, 4-pole
The motor has two outputs for potential-free signals via
two internal relays.
The signal outputs can be set to "Operation", "Pump
running", "Ready", "Alarm" and "Warning".
The functions of the two signal relays appear from the
table below.
Contact position for signal relays when activated
Description

Grundfos Eye

Operation

Pump
running

Ready

Alarm

Warning

Power off.

Off

NO NC

NO NC

NO NC

NO NC

NO NC

Normal, Min.
or Max.

Pump running in "Normal"


mode.
Green, rotating

NO NC

NO NC

NO NC

NO NC

NO NC

Pump running in "Manual"


mode.

Manual
Green, rotating

NO NC

NO NC

NO NC

NO NC

NO NC

Pump in "Stop" operating


mode.

Stop
Green, steady

NO NC

NO NC

NO NC

NO NC

NO NC

Warning, but the pump is


running.

Normal, Min.
or Max.
Yellow, rotating

NO NC

NO NC

NO NC

NO NC

NO NC

Warning, but the pump is


running in "Manual" mode.

Manual
Yellow, rotating

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

Warning, but the pump was


stopped via "Stop"
command.

Stop
Yellow, steady

NO NC

Alarm, but the pump is


running.

Normal, Min.
or Max.
Red, rotating

NO NC

NO NC

NO NC

NO NC

NO NC

Alarm, but the pump is


running in "Manual" mode.

Manual
Red, rotating

NO NC

NO NC

NO NC

NO NC

NO NC

Pump stopped due to an


alarm.

Stop
Red, flashing

52

Operating
mode

NO NC

NO NC

NO NC

NO NC

NO NC

11

TP, TPD, TPE

User interfaces for TPE pumps

The following applies to the pumps below:


TPE Series 1000 pumps with the following motor
sizes:
3-22 kW, 2-pole
1.5 - 18.5 kW, 4-pole
The operating condition of the pump is indicated by the
green (pos. A) and red (pos. B) indicator lights on the
pump control panel and inside the terminal box.
See fig. 48.

TM05 8592 2513

Fig. 48 Position of indicator lights

Furthermore, the pump incorporates an output for a


potential-free signal via an internal relay.

53

11

TP, TPD, TPE

User interfaces for TPE pumps

The functions of the two indicator lights and the signal relay are as shown in the following table:
Indicator lights
Fault
(red)

Operation
(green)

Off

Off

Signal relay activated during:


Fault/Alarm,
Warning and
Relubricate

Permanently on

Permanently on

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

Flashing

The pump has been set to stop.


NO NC

NO NC

Off
C

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

NO NC

Permanently on

The pump has stopped because of a


"Fault"/"Alarm" or is running with a
"Warning" or "Relubricate" indication.
If the pump was stopped, restarting will be
attempted (it may be necessary to restart
the pump by resetting the "Fault"
indication).
The pump is operating, but it has or has had
a "Fault"/"Alarm" allowing the pump to
continue operation or it is operating with a
"Warning" or "Relubricate" indication.
If the cause is "Sensor signal outside signal
range", the pump will continue operating
according to the max. curve, and the fault
indication cannot be reset until the signal is
inside the signal range.
If the cause is "Setpoint signal outside
signal range", the pump will continue
operating according to the min. curve, and
the fault indication cannot be reset until the
signal is inside the signal range.
The pump has been set to stop, but it has
been stopped because of a "Fault".

Flashing
C

NO NC

NO NC

Resetting of fault indication


A fault indication can be reset in one of the following
ways:
Briefly press
or
on the pump. This will not
change the setting of the pump.
A fault indication cannot be reset by pressing
or
if the buttons have been locked.
Switch off the power supply until the indicator lights
are off.
Switch the external start/stop input off and then on
again.
Use the Grundfos GO Remote.

54

Description

The pump is operating.

Permanently on

Pump running

Permanently on
C

Off

Ready

The power supply has been switched off.


C

Off

Operating

NO NC

NO NC

12

TP, TPD, TPE

Communication with TPE pumps

Communication

12. Communication
Remote control
The operator can monitor and change control modes
and settings of the pump with the Grundfos GO
Remote. See Grundfos GO Remote, page 35.

Communication with TPE pumps is possible via a


central building management system, remote control
(Grundfos GO Remote) or control panel.
Central building management system
The operator can communicate with a TPE pump at a
distance. Communication can take place via a central
building management system allowing the operator to
monitor and change control modes and setpoint
settings.

CIM
CIM
CIM
CIM
CIM
CIM

100:
150:
200:
250:
270:
300:

100:
150:
200:
250:
270:
300:

TPE Series 1000 with the


following motor sizes:
- 0.12 - 2.2 kW, 2-pole
- 0.12 - 1.1 kW, 4-pole
TPE Series 1000 with the
following motor sizes:
- 11 - 22 kW, 2-pole
- 11 - 18.5 kW, 4-pole

LonWorks
PROFIBUS DP
Modbus RTU
GSM
GRM
BACnet MS/TP

LonWorks
PROFIBUS DP
Modbus RTU
GSM/GPRS
GRM
BACnet MS/TP

TPE Series 1000 with the


following motor sizes:
- 3 - 7.5 kW, 2-pole
- 1.5 - 7.5 kW, 4-pole
TM05 7520 1113

CIU
CIU
CIU
CIU
CIU
CIU

Fig. 49 Structure of a central building management system

55

13

TP, TPD, TPE

Speed regulation of TPE pumps

13. Speed regulation of TPE pumps


Affinity equations
Normally, TPE pumps are used in applications
characterised by a variable flow. Consequently, it is not
possible to select a pump that is constantly operating
at its optimum efficiency.
In order to achieve optimum operating economy, the
pump should be selected at the flow rate at the duty
point close to the optimum efficiency (eta) for most
operating hours.
Between the min. and max. performance curves, TPE
pumps have an infinite number of performance curves
each representing a specific speed. It may therefore
not be possible to select a duty point close to the max.
curve.

Q
n
n
n
-------- = -----Q
n
x
x

Hn
Hx

H
n n 2
n
------= ------
H
n x
x

nn
nx

Eta

Q
Qx

Qn

n-----1

H
H
[m]

nx

[m]

nn

Max. curve

[m3h]
QQ[m/h]

TM01 4916 4803

Fig. 50 Min. and max. performance curves

In situations where it is not possible to select a duty


point close to the max. curve, use the affinity equations
below. The head (H), the flow rate (Q) and the input
power (P) are the appropriate variables you need for
calculating the motor speed (n).
Note: The approximated formulas apply on condition
that the system characteristic remains unchanged for
nn and nx, and that it is based on the formula H = k x
Q2 where k is a constant.
The power equation implies that the pump efficiency is
unchanged at the two speeds. In practice this is not
quite correct.
Finally, it is worth noting that the efficiency of the
frequency converter and the motor must be taken into
account if a precise calculation of the power saving
resulting from a reduction of the pump speed is
wanted.

56

Qn
Pn
n n 3
------- = -----
Px
n x

nn

Pn

Min. curve

Qx

nx

Px

TM00 8720 3496

Fig. 51 Affinity equations

Legend
Hn
Hx
Qn
Qx
nn
nx
n
x
Pn
Px

Rated head in metres


Current head in metres
Rated flow rate in m3/h
Current flow rate in m3/h
Rated motor speed in min-1
Current motor speed in min-1
Rated efficiency in %
Current efficiency in %
Rated power in kW
Current power in kW

WinCAPS and WebCAPS


WinCAPS and WebCAPS are selection programs
offered by Grundfos.
The two programs make it possible to calculate the
specific duty point and energy consumption of a TPE
pump.
When you enter the dimensions of the pump,
WinCAPS and WebCAPS can calculate the exact duty
point and energy consumption. For further information,
see page 171.

14

TP, TPD, TPE

Control of TP, TPE pumps


connected in parallel

Start-up wizard

In some applications, parallel pump operation is


required for one or more of the following reasons:
One pump cannot achieve the required performance
(flow).
Standby capacity is required to ensure reliability of
supply.
Overall efficiency needs to be improved in case of
big variations in the flow demand.
The table below lists the different possibilities of
controlling TP, TPE pumps connected in parallel.

Parallel-operation
control possibilities

Built-in alternation /
standby function

Built-in parallel
operation function

3 - 22 kW, 2-pole
1.5 - 18.5 kW, 4-pole

TPE
TPE
Series 1000 Series 1000
0.12 - 2.2 kW, 2-pole
0.12 - 1.1 kW, 4-pole

TP

TP, TPE pumps in parallel

14. TP, TPE pumps in parallel


Correct installation and commissioning is a
prerequisite for attaining optimum performance of the
system and trouble-free operation year in and year out.
During commissioning of the system, a start-up wizard
is shown on the display of the Control MPC.
The wizard will guide the operator through the various
steps via a series of dialogue boxes to ensure that all
settings are done in the correct sequence.
Application-optimised software
Control MPC incorporates application-optimised
software which helps you set up your system to the
application in question.
Furthermore, navigating through the menus of the
controller is done in a user-friendly way - you do not
need any training to be able to set and monitor the
system.
Ethernet connection
Control MPC incorporates an Ethernet connection
which makes it possible to get full and unlimited
access to the setting and monitoring of the system via
a remote PC.
Service port (GENI TTL)
The service port of the Control MPC enables easy
access to updating software and data logging in
service situations.

Control MPC

External communication

Available.

TP, TPE pumps connected to Control MPC


TP, TPE pumps can be connected directly to Grundfos
Control MPC.
Control MPC can control up to six pumps.
By means of an external sensor, Control MPC can
ensure optimum adaptation of the performance to the
demand by closed-loop control of:
proportional differential pressure
constant differential pressure
differential pressure (remote)
flow
temperature.
Control MPC incorporates features such as:

Control MPC enables communication with other


fieldbus protocols. In order to communicate with other
fieldbus protocols a GENIbus module and a gateway is
needed.
Control MPC can communicate with LON, PROFIBUS,
Modbus, BACnet, GSM/GPRS or GRM via Grundfos
CIU.
Note: For further information about Control MPC, see
the data booklet titled Control MPC. The data booklet
is available in WebCAPS, on www.grundfos.com.
For further information on WebCAPS, see page 171.

57

15

TP, TPD, TPE

TP pumps connected to Grundfos


CUE, external frequency
converters

Smart user interface

TM04 3283 4108

Grundfos CUE

15. Grundfos CUE

Fig. 53 Grundfos CUE user interface

GrA 4404

Grundfos CUE features a unique user-friendly control


panel with graphic display and easy-to-use buttons.

Fig. 52 Grundfos CUE product range

Grundfos CUE is a complete range of wall-mounted


frequency converters for pump control in a wide range
of applications.
Grundfos CUE provides a variety of benefits to the
end-user.
The benefits include:
Grundfos E-pump functionality and user interface.
Application- and pump family-related functions.
Increased comfort compared to fixed-speed pump
solutions.
Simple installation and commissioning compared to
standard frequency converters.
Enables speed control of pumps up to 250 kW.

Functions
Intuitive start-up guide
The start-up guide enables easy installation and
commissioning as well as plug-and-pump
convenience. Few settings need to be made by the
installer as the rest is done automatically or preset
from the factory.

58

Controlling the value you choose


Grundfos CUE has a built-in PI controller offering
closed-loop control of a desired value.
The values include:
constant differential pressure
proportional pressure
constant temperature
constant differential pressure
constant flow.
Wide product range
The CUE product range is quite comprehensive,
covering five different voltage ranges, enclosure
classes IP20/21 (Nema 1) and IP54/55 (Nema 12), and
a wide range of output powers.
The table below provides a general overview.
Input voltage [V]
1
3
3
3
3

x
x
x
x
x

200-240
200-240
380-500
525-600
525-690

Output voltage [V]


3
3
3
3
3

x
x
x
x
x

200-240
200-240
380-500
525-600
525-690

Motor [kW]
1.1 - 7.5
0.75 - 45
0.55 - 250
0.75 - 7.5
11 - 250

External communication
Grundfos CUE can communicate with LON,
PROFIBUS, Modbus, BACnet or GSM/GPRS via
Grundfos CIU.

16

TP, TPD, TPE

Motor

Motor data

16. Motor data


Motor range

The motor fitted on TP pumps is a totally enclosed,


fan-cooled motor with main dimensions to IEC and DIN
standards. Electrical tolerances to IEC 34.

kW

Mounting designation

0.25

Pump type

Mounting designation - IEC 34-7

TP Series 100
TP Series 200

IM 3601 (IM B 14) / IM 3611 (IM V 18)

TP Series 300

IM 3001 (IM B 5) / IM 3011 (IM V 1)

TP Series 400

IM 3001 (IM B 5) / IM 3011 (IM V 1)

Relative humidity:
Enclosure class:
Insulation class:
Ambient temperature:

Max. 95 %
IP55
F (IEC 85)
See page 16.

If the pump is installed in humid locations, open the


lowest drain hole in the motor. This will reduce the
motor enclosure class to IP44.
High-efficiency motors
TP pumps are primarily fitted with motors that meet the
legislative requirements of the EuP IE3 or IE2 grade
depending on voltage and motor size. For further
information see Motors, pages 60 to 62.
TPE pumps with 2-pole motors below 3 kW and 4-pole
motors below 1.5 kW are fitted with permanent-magnet
motors which have an efficiency that exceeds the IE4
demands - including the energy consumption of the
integrated frequency converter (compared to IE levels
in IEC 60034-30-1 Ed. 1 (CD)).
TPE pumps with three-phase 2-pole motors from 3 to
22 kW are fitted with motors equivalent to IE3.
TPE pumps with three-phase 4-pole motors from 1.5 to
15 kW are fitted with motors equivalent to IE3.
TPE pumps with 4-pole three-phase motors of 18.5 kW
are equipped with motors equivalent to IE2.

Mains-operated motors
2-pole

4-pole

Electronically
speed-controlled motors
2-pole

4-pole

0.37
0.55
0.75
1.1

MGE*

1.5
MG

2.2
3.0
4.0

MGE*

MG

5.5

MGE

7.5

MGE

11.0
15.0
18.5
22.0
30.0
37.0
45.0
55.0
75.0
90.0

Siemens

Siemens

110.0
132.0
160.0
200.0
250.0
315.0
* Permanent-magnet motors
MG and MGE are Grundfos motor brands.
Siemens is a sourced high-quality motor brand.
The grey-shaded areas indicate non-available motors.

59

16

TP, TPD, TPE

Motor data

Electrical data, mains-operated motors


Electrical data, 2-pole

3 x 220-240/380-420 V and 3 x 255-277/440-480 V

3 x 220-240/380-420 V

3 x 255-277/440-480 V
*

Motor
[kW]

I1/1
[A]

Cos 1/1 *

[%]

n
[min-1]

IStart
-----------I 1/1

30.0
37.0
45.0
55
75
90
110
132
160

97.0-87.0/56.0-50.0
120-105/69.0-62.0
140-126/81.0-73.0
166-154/96-89
235-210/135-122
280-250/161-145
335-300/194-174
400-265/230-210
450-405/260-235

0.89
0.90
0.90
0.901
0.898
0.907
0.907
0.92
0.92

92.4
93.0
94.2
94.0
93.8
94.4
95.1
94.8
95.3

3545
3540
3556
3570
3570
3570
3579
3579
3582

6.1
5.8
7.6
7.3
7.4
7.8
7.8
8.0
9.1

*
**

I1/1
[A]

Cos 1/1**

**
[%]

n **
[min-1]

IStart
-----------I 1/1

IE
class

94.0-87.0/54.0-50.0
116-107/67.0-61.0
137-128/79.0-74.0
166-154/96-89
225-210/130-122
270-250/156-143
320-295/186-171
390-355/225-205
470-435/270-250

0.87
0.87
0.89
0.90
0.89
0.90
0.91
0.91
0.92

93.0
93.6
93.6
93.6
94.5
94.5
95.0
95.4
95.4

3550
3550
3560
3575
3575
3575
3582
3582
3582

6.6
6.7
6.8
6.7
6.8
7.2
7.2
7.1
7.7

IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3

IE
Motor
class [kW]
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3

34.5
42.5
51.0
62
84
101
123
148
180

Applies to 230/400 V
Applies to 265/460 V

Electrical data, 2-pole


Motor
[kW]
0.37
0.55
0.75
1.1

I1/1
[A]
1.5-1.44/
0.87-0.83
2.15-2.05/
1.25-1.2
2.95-2.75/
1.70-1.60
4.15-4.00/
2.40-2.30

3 x 220-255/380-440 V

Cos 1/1

[%]

n [min-1]

IStart
-----------I 1/1

IE
class

0.85-0.76

78-79

3410-3470

5.5-6.5

5-6

0.85-0.76 80.5-82 3390-3460


0.86-0.77

77

3410-3470

6-7.4

IE3

0.88-0.80

82.5

3420-3470

4.3-5

IE3

Electrical data, 2-pole


Motor
[kW]
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0
18.5
22.0

60

I1/1
[A]
5.35-4.7/
3.10-2.7
7.7-6.35/
4.45-3.7
10.8-9.35/
6.20-5.40
13.6-11.8/
7.8-6.8
18.4-16.2/
10.6-9.30
24.6-20.8/
14.2-12.0
36.0-30.0/
20.8-17.2
48.5-39.0/
28.0-22.4
59.0-47.0/
34.0-27.0
69.5-56.5/
40.0-32.5

Cos 1/1

3 x 220-277/380-480 V
[%]

n [min-1]

IStart
-----------I 1/1

IE
class

0.90-0.81 82.5-85.5 3470-3530 7.8-10.5 IE2-IE3


0.91-0.85 85.2-86.5 3470-3530

7.8-11 IE2-IE3

0.91-0.84

87.5

3480-3530

8.6-11 IE2-IE3

0.91-0.82

88.5

3510-3540

10-14

IE3

0.90-0.80

89.5

3510-3550

10.2-14.
8

IE3

0.90-0.82 89.5-90.2 3490-3530 6.8-10.5 IE2-IE3


0.89-0.83 90.2-91 3520-3550 5.8-8.9 IE2-IE3
0.90-0.86 90.2-91 3520-3550 5.8-8.9 IE2-IE3
0.90-0.88 91.0-91.7 3520-3550 6.1-9.7 IE2-IE3
0.91

91.7

3520-3560 6.5-10.4

IE3

Electrical data, 2-pole


Motor
[kW]

I1/1
[A]

1.5
2.2
3.0
4.0
5.5

3.1-2.7
4.45-3.7
6.2-5.4
7.8-6.8
10.6-9.30
14.2-12.0/
8.20-8.10
20.8-17.2/
12.0-11.6
28.0-22.4/
16.2-15.6
34.0-27.0/
19.6-18.8
40.0-32.5/
23.0-22.2

7.5
11.0
15.0
18.5
22.0

Cos 1/1

3 x 380-480/660-690 V
[%]

n [min-1]

IStart
-----------I 1/1

IE class

0.90-0.81 82.5-85.5 3470-3530 7.8-10.5 IE2-IE3


0.91-0.85 85.2-86.5 3470-3530 7.8-11 IE2-IE3
0.91-0.84
87.5
3480-3530 8.6-11
IE2
0.91-0.82
88.5
3510-3540 10.8-10.8 IE3
0.9-0.80
89.5
3510-3550 10.2-14.8 IE3
0.90-0.82 89.5-90.2 3490-3530 6.8-10.5 IE2-IE3
0.89-0.83 90.2-91.0 3520-3550

5.8-8.9

IE2-IE3

0.90-0.86 90.2-91.0 3520-3550

5.8-8.9

IE2-IE3

0.90-0.88 91.0-91.7 3520-3550

6.1-9.7

IE2-IE3

0.91

91.7

3520-3560 6.5-10.4

IE3

16

TP, TPD, TPE

3 x 380-420/660-690 V and 3 x 440-480 V

3 x 380-420/660-690 V
Motor
[kW]
30.0
37.0
45.0
55.0
75.0
90.0
110.0
132.0
160.0
-

I1/1
[A]

3 x 440-480 V

Cos 1/1*

*
[%]

n*
[min-1]

IStart
-----------I 1/1

IE
class

Motor
[kW]

I1/1
[A]

Cos 1/1 **

**
[%]

n**
[min-1]

IStart
-----------I 1/1

IE
class

0.89

92.4

3545

6.1

IE3

34.5

54.0 - 50.0

0.87

93.0

3550

6.6

IE3

0.90

93.0

3540

5.8

IE3

42.5

67.0 - 61.0

0.87

93.6

3550

6.7

IE3

0.90

94.2

3556

7.6

IE3

51.0

79.0 - 74.0

0.89

93.6

3560

6.8

IE3

0.90

94.0

3570

7.3

IE3

62.0

96.0 - 89.0

0.90

93.6

3575

6.7

IE3

0.90

93.8

3570

7.4

IE3

84.0

130 - 122

0.89

94.5

3575

6.8

IE3

0.91

94.4

3570

7.8

IE3

101.0

156 - 143

0.90

94.5

3575

7.2

IE3

0.91

95.1

3579

7.8

IE3

123.0

186 - 171

0.91

95.0

3582

7.2

IE3

0.92

94.8

3579

8.0

IE3

148.0

225 - 205

0.91

95.4

3582

7.1

IE3

0.92

95.3

3582

9.1

IE3

180.0

270 - 250

0.92

95.4

3582

7.7

IE3

224.0
280.0

335 - 305
420 - 385

0.92
0.92

95.8
95.4

3582
3585

7.1
8.7

IE3
IE3

56.0 - 50.0/
32.0 - 30.5
69.0 - 62.0/
38.5 - 37.0
81.0 - 73.0/
47.0 - 44.5
96.0 - 89.0/
55.0 - 54.0
135 - 122/
78.0 - 74.0
161 - 145/
93.0 - 88.0
194 - 174/
112 - 106
230 - 210/
133 - 127
260 - 235/
150 - 142
-

Motor data

Electrical data, 2-pole

* Applies to 400/690 V
** Applies to 400 V

Electrical data, 4-pole

3 x 220-240/380-420 V and 3 x 255-277/440-480 V

3 x 220-240/380-420 V
Motor
[kW]
18.5
22
30
37
45
55
75
90
110
132
160
200
*
**

I1/1
[A]

3 x 255-277/440-480 V

Cos 1/1 *

*
[%]

n*
[min-1]

IStart
-----------I 1/1

0.84

92.4

1765

6.2

IE3

21.3

0.84

92.4

1765

6.0

IE3

25.3

63.0 - 57.0/
36.5 - 33.0
73.5 - 70/
42.5 - 40.5
99.5 - 93.5/
57.5 - 54.0
120 - 109/69 - 63
147 - 132/85 - 76
177 - 159/102 - 92
240 - 215/139 - 125
290 - 260/166 - 150
345 - 315/200 - 181
415 - 370/240 - 215
470 - 425/270 - 245
580 - 520/335 - 300

IE
Motor
class [kW]

0.85

93.0

1765

6.1

IE3

34.5

0.86
0.86
0.87
0.87
0.87
0.87
0.88
0.88
0.88

94.0
94.3
94.7
94.8
94.9
95.4
95.8
96.1
95.7

1776
1775
1780
1783
1783
1786
1788
1789
1788

5.4
5.3
5.4
5.4
5.6
5.5
5.8
5.8
6.0

IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3

42.5
52
63.0
86.0
104
127
152
184
230

I1/1
[A]
62.5 - 57.0/
36.0 - 33.0
74.5 - 70.0/
43.0 - 40.5
99.0 - 92.5/
57.0 - 53.5
119 - 111/69 - 64
146 - 137/84 - 79
175 - 163/101 - 94
235 - 220/136 - 127
285 - 265/165 - 153
345 - 320/199 - 185
405 - 375/235 - 220
495 - 460/285 - 265
620 - 580/360 - 335

Cos 1/1**

**
[%]

n**
[min-1]

IStart
-----------I 1/1

IE
class

0.83

93.6

1770

7.0

IE3

0.83

93.6

1770

6.9

IE3

0.85

93.0

1770

7.2

IE3

0.86
0.86
0.87
0.87
0.87
0.87
0.88
0.88
0.88

93.6
94.1
94.1
95.4
95.0
95.8
96.2
96.2
95.4

1778
1778
1782
1785
1785
1788
1788
1788
1788

6.7
6.6
6.7
6.8
7.0
6.9
7.2
7.2
7.5

IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3

Applies to 230/400 V
Applies to 265/460 V

Electrical data, 4-pole

3 x 220-255/380-440 V

Motor
[kW]

I1/1
[A]

Cos 1/1

[%]

0.12
0.25
0.37
0.55
0.75

0.37
1.21/0.7
1.72/0.99
2.4/1.4
3.1/1.8

0.8-0.69
0.82-0.72
0.83-0.75
0.84-0.76

71-72
73-74
77-80
77-81

n [min-1]

IStart
-----------I 1/1

1680-1720 4-4.7
1680-1720 4-4.7
1660-1710 3.9-4.5
1660-1710 3.9-4.7

IE
class
IE2

61

16

TP, TPD, TPE

Motor data

Electrical data, 4-pole


Motor
[kW]
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11.0
15.0

I1/1
[A]
3.10-2.95/
1.80-1.70
4.50/2.60
5.90-5.65/
3.40-3.25
8.15-7.45/
4.70-4.30
10.6-9.55/
6.10-5.50
14.8-14.4/
8.60-8.30
19.0-16.2/
11.0-9.40
25.5-21.6/
14.7-12.5
36.0-31.0/
20.8-17.8
50-42/
29-24.2

Cos 1/1

3 x 220-277/380-480 V
n [min-1]

[%]

IStart
-----------I 1/1

Electrical data, 4-pole

IE
class

0.79-0.67 82.5-85.5 1730-1760 5.9-7.5 IE2-IE3


0.76-0.60

84.0

1740-1770 7.1-9.1

IE2

0.78-0.65 84.0-86.5 1740-1770 6.6-9.3 IE2-IE3


0.83-0.71

87.5

1740-1760 5.9-7.6

IE2

1760-1780 6.5-9.7

0.88-0.81

91.0

1760-1770 6.5-9.8 IE2-IE3

[%]

n [min-1]

IStart
-----------I 1/1

IE
class

0.75
1.1
1.5
2.2
3.0
4.0

1.80-1.70
2.60-2.60
3.40-3.25
4.70-4.30
6.10-5.50
8.60-8.30
11.0-9.40/
6.35-6.20
14.7-12.5/
8.50-8.25
20.8-17.8/
12.0-11.8
29.0-24.2/
16.6-16.4

0.79-0.67
0.76-0.60
0.78-0.65
0.83-0.71
0.85-0.73
0.79-0.64

82.5-85.5
84
84-86.5
87.5
87.5-89.5
87.5-89.5

1730-1760
1740-1770
1740-1770
1740-1760
1730-1760
1750-1770

5.9-7.5
7.1-9.1
6.6-9.3
5.9-7.6
6.2-8.8
7.7-9.1

IE2-IE3
IE2
IE2-IE3
IE2
IE2-IE3
IE2-IE3

15.0

0.88-0.80 89.5-91.7 1740-1770 5.9-8.9 IE2-IE3


91.0

Cos 1/1

11.0

IE2

0.90-0.81

I1/1
[A]

7.5

0.79-0.64 87.5-89.5 1750-1770 7.7-9.1 IE2-IE3


0.88-0.79 87.0-89.5 1750-1770 6.7-8.5

Motor
[kW]

5.5

0.85-0.73 87.5-89.5 1730-1760 6.2-8.8 IE2-IE3

0.88-0.79 87.0-89.5 1750-1770 6.7-8.5 IE2-IE3


0.88-0.80 89.5-91.7 1740-1770 5.9-8.9 IE2-IE3
0.90-0.81

91

1760-1780 6.5-9.7

0.88-0.81

91

1760-1770 6.5-9.8 IE2-IE3

3 x 380-420/660-690 V and 3 x 440-480 V

3 x 380-420/660-690 V
I1/1
[A]

18.5
22.0
30.0
37.0
45.0
55.0
75.0
90.0
110.0
132.0
160.0
200.0
250.0
300.0

36.5 - 33.0/21.0 - 20.0


42.5 - 40.5/24.5 - 24.0
57.5 - 54.0/33.5 - 32.0
69.0 - 63.0/40.0 - 38.0
85.0 - 76.0/49.0 - 46.0
102 - 92.0/59.0 - 56.0
139 - 125/80.0 - 76.0
166 - 150/96.0 - 91.0
200 - 181/115 - 109
240 - 215/138 - 131
270 - 245/156 - 148
335 - 300/192 - 182
415 - 370/240 - 225
560 - 500/320 - 305

* Applies to 400/690 V
** Applies to 400 V

62

IE2

IE2

Electrical data, 4-pole

Motor
[kW]

3 x 380-480/660-690 V

3 x 440-480 V

Cos 1/1 *

*
[%]

n*
[min-1]

IStart
-----------I 1/1

IE
class

Motor
[kW]

I1/1
[A]

Cos 1/1 **

**
[%]

n**
[min-1]

IStart
-----------I 1/1

IE
class

0.84
0.84
0.85
0.86
0.86
0.87
0.87
0.87
0.87
0.88
0.88
0.88
0.86
0.85

92.4
92.4
93.0
94.0
94.3
94.7
94.8
94.9
95.4
95.8
96.1
95.7
95.9
95.9

1765
1765
1765
1776
1775
1780
1783
1783
1786
1788
1789
1788
1789
1788

6.2
6.0
6.1
5.4
5.3
5.4
5.4
5.6
5.5
5.8
5.8
6.0
7.7
7.9

IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3

21.3
25.3
34.5
42.5
52.0
63.0
86.0
103.5
126.5
151.8
184.0
230.0
-

36.0 - 33.0
43.0 - 40.5
57.0 - 53.5
69.0 - 64.0
84.0 - 79.0
101 - 94.0
136 - 127
165 - 153
199 - 185
235 - 220
285 - 265
360 - 335
-

0.83
0.83
0.85
0.86
0.86
0.87
0.87
0.87
0.87
0.88
0.88
0.88
-

93.6
93.6
93.0
93.6
94.1
94.1
95.4
95.0
95.8
96.2
96.2
95.4
-

1770
1770
1770
1778
1778
1782
1785
1785
1788
1788
1788
1788
-

7.0
6.9
7.2
6.7
6.6
6.7
6.8
7.0
6.9
7.2
7.2
7.5
-

IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
IE3
-

16

TP, TPD, TPE

Motor data

Electrical data, speed-controlled motors


Electrical data, 3 x 380-500 V, 2000 min-1 (4-pole)
Motor [kW]

I1/1 [A]

1.1

2.20 - 1.90

Electrical data, 3 x 380-500 V, 4000 min-1 (2-pole)


Motor [kW]

I1/1 [A]

2.2

4.15 - 3.40

Electrical data, 2-pole

3 x 380-480 V, 2900 min-1

Motor [kW]

I1/1 [A]

0.75

2.0 - 1.8

1.1

2.6 - 2.3

1.5

3.3 - 2.7

2.2

4.6 - 3.8

3.0

6.2 - 5.0

4.0

8.1 - 6.6

5.5

11.0 - 8.8

7.5

14.8 - 11.6

11.0

22.5 - 18.8

15.0

30.0 - 26.0

18.5

37.0 - 31.0

22.0

43.5 - 35.0

Electrical data, 4-pole

3 x 380-480 V, 1450 min-1

Motor [kW]

I1/1 [A]

0.75

1.8 - 1.9

1.1

2.5 - 2.2

1.5

3.3 - 2.9

2.2

4.6 - 3.8

3.0

6.2 - 5.0

4.0

8.1 - 6.6

5.5

11.0 - 9.00

7.5

15.0 - 12.0

11.0

22.0 - 17.8

15.0

30.0 - 25.4

18.5

37.0 - 30.0

63

17

TP, TPD, TPE

Mechanical installation
TP, TPD, TPE pumps with motors smaller than 11 kW
can be installed in horizontal or vertical pipework.

TM00 3734 0897

TM02 7533 3703

Installation

17. Installation

Fig. 54 Installation of motor sizes smaller than 11 kW

For further information about identification of TP Series


300 models, see pages 21 to 23.
Cooling

Fig. 55 Installation of motor sizes of 11 kW and up

Note: The motor must never point downwards.


Install the pumps in such a way that strain from the
pipework is not transferred to the pump housing.
Pumps with motors smaller than 11 kW may be
suspended directly in the pipes, provided the pipework
can support the pump. If not, install the pump on a
mounting bracket or base plate.
Pumps with motors of 11 kW and up may only be
installed in horizontal pipes with the motor placed in
vertical position. Always install the pump on an even
and rigid foundation.
When installing a twin-head pump in a horizontal pipe
and with horizontal shaft, fit the upper pump housing
with an automatic air vent.
Twin-head pump housings have two Rp 1/4 tappings
(TP Series 200) or four Rp 1/8 tappings (TP Series
300) for mounting of automatic air vents.

To ensure sufficient cooling of motor and electronics,


observe the following:
Place the pump in such a way that sufficient cooling
is ensured.
Make sure that the temperature of the cooling air
does not exceed 40 C.
Keep the motor cooling fins, holes in fan cover and
fan blades clean.
Make sure the frequency for the motor is at least
6 Hz (12 % of maximum speed). The shaft seal may
generate noise at speeds below 25 % of maximum
speed.
Condensation cover for TPE pumps
When installing TPE pumps outdoors, provide the
motor with a suitable cover to avoid condensation on
the electronic components and to protect the pump
and motor against the direct effects of the elements.
When mounting the condensation cover on top of the
motor, make sure to leave enough space for the air to
cool the motor.

TM02 8514 0304

TM00 3735 0897

TP, TPD, TPE pumps with motors of 11 kW and up may


only be installed in horizontal pipes with the motor in
vertical position.

64

Fig. 56 Tappings for mounting of automatic air vents in TP


Series 200 and TP Series 300

Fig. 57 MGE motors with condensation cover

17

TP, TPD, TPE

Frequency
[Hz]

Pump type
200-280/4
200-320/4
200-360/4
200-390/4

60
60
60
60

Noise and vibration are generated by the revolutions of


the motor and pump and by the flow in pipes and
fittings. The effect on the environment is subjective
and depends on correct installation and the state of the
remaining system.
Elimination of noise and vibrations is best achieved by
means of a concrete foundation, vibration dampers
and expansion joints.

Expansion joint

Vibration dampers

Fig. 58 Foundation of TP pump

Concrete foundation
Install the pump on a plane and rigid concrete
foundation. This is the optimum solution for vibration
dampening. As a rule of thumb, the weight of a
concrete foundation should be 1.5 times the pump
weight.

TM02 4993 2102

Concrete foundation

TM03 9190 3507

TP
TP
TP
TP

Recommended concrete foundations for TP(D)


Series 300 pumps
For TP Series 300 pumps with weights of 150 kg or
more, we recommend mounting the pump on a
concrete foundation with the dimensions stated in the
table below. The same recommendation applies to
TPD Series 300 pumps with weights of 300 kg or more.

Installation

Elimination of noise and vibrations


In order to achieve optimum operation and minimum
noise and vibration, consider vibration dampening of
the pump. Generally, always consider this for pumps
with motors of 11 kW and up, but for motors of 90 kW
and up as well as the pumps stated in the table below,
vibration dampening is mandatory. Smaller motor
sizes, however, may also cause undesirable noise and
vibration.

Fig. 59 Foundation for TP(D) Series 300 pumps

Pump mass
[kg]
150
200
250
300
350
400
450
500
550
600
650
700
750
800
850
900
950
1000
1050
1100
1150
1200
1250
1300
1350
1400
1450
1500
1550
1600
1650
1700

Concrete foundation dimensions


X (Height)
[mm]

Y (Length)
[mm]

Z (Width)
[mm]

280
310
330
360
375
390
410
420
440
450
460
470
480
490
500
510
520
530
540
550
560
560
570
580
590
600
600
610
620
620
630
635

565
620
670
710
750
780
810
840
870
900
920
940
970
990
1010
1030
1050
1060
1080
1100
1100
1130
1150
1160
1180
1190
1200
1220
1230
1250
1250
1270

565
620
670
710
750
780
810
840
870
900
920
940
970
990
1010
1030
1050
1060
1080
1100
1100
1130
1150
1160
1180
1190
1200
1220
1230
1250
1250
1270

65

17

TP, TPD, TPE

Expansion joints
Install expansion joints for these reasons:
to absorb expansions/contractions in the pipework
caused by changing liquid temperature
to reduce mechanical strains in connection with
pressure surges in the pipework
to isolate mechanical structure-borne noise in the
pipework (only rubber bellows expansion joints).
Note: Do not install expansion joints to compensate for
inaccuracies in the pipework such as centre
displacement of flanges.
Fit expansion joints at a distance of minimum 1 to 1.5
times the nominal flange diameter away from the pump
on the suction as well as on the discharge side.
This will prevent the development of turbulence in the
expansion joints, resulting in better suction conditions
and a minimum pressure loss on the pressure side.
At high water velocities (> 5 m/s) we recommend
installing larger expansion joints corresponding to the
pipework. See fig. 60.

TM04 9629 4810

Expansion joints

Fig. 60 TP pump installed with larger expansion joints

66

TM02 4979 1902 - TM02 4981 1902

The illustration below shows examples of rubber


bellows expansion joints with or without limit rods.

Fig. 61 Examples of rubber bellows expansion joints

Expansion joints with limit rods can be used to reduce


the effects of the expansion/contraction forces on the
pipework. We always recommend expansion joints
with limit rods for flanges larger than DN 100.
Anchor the pipes in such a way that they do not stress
the expansion joints and the pump. Follow the
suppliers instructions and pass them on to advisers or
pipe installers.
The illustration below shows an example of a metal
bellows expansion joint with limit rods.

TM02 4980 1902

Installation

Vibration dampers
To prevent the transmission of vibrations to buildings,
we recommend isolating the pump foundation from
building parts by means of vibration dampers.
The selection of the right vibration damper requires the
following data:
forces transmitted through the damper
motor speed considering speed control, if any
required dampening in % (suggested value is 70 %).
The right damper varies from installation to installation,
and a wrong damper may increase the vibration level.
Vibration dampers should therefore be sized by the
supplier.
If you install the pump on a foundation with vibration
dampers, always fit expansion joints on the pump
flanges. This is important to prevent the pump from
"hanging" in the flanges.

Fig. 62 Example of metal expansion joint

Due to the risk of rupture of the rubber bellows, metal


bellows expansion joints may be preferred at
temperatures above 100 C combined with high
pressure.

Terminal box positions

Frequency converter operation

TP single-head pumps

Motors types Siemens, MG 71 and MG 80 for supply


voltages up to and including 440 V (see motor
nameplate) must be protected against voltage peaks
higher than 650 V between the supply terminals.
Grundfos motors:
All three-phase Grundfos motors from frame size 90
and up can be connected to a frequency converter.
The connection of a frequency converter will often
have the effect that the motor insulation system is
loaded more and that the motor will be more noisy than
during normal operation. In addition, large motors are
loaded by bearing currents caused by the frequency
converter.
In the case of frequency converter operation, the
following should be considered:
In 2-, 4- and 6-pole motors of 45 kW and up, one of the
motor bearings should be electrically isolated to
prevent damaging currents from passing through the
motor bearings.
In the case of noise-critical applications, the motor
noise can be reduced by fitting a dU/dt filter between
the motor and the frequency converter. In particularly
noise-critical applications, it is recommended to fit a
sinusoidal filter.
The length of the cable between motor and frequency
converter affects the motor load. It should therefore be
checked that the cable length meets the specifications
laid down by the frequency converter supplier.
For supply voltages between 500 and 690 V, either a
dU/dt filter should be fitted to reduce voltage peaks or
a motor with reinforced insulation should be used.
For supply voltages of 690 V, a motor with reinforced
insulation should be used, and a dU/dt filter should be
fitted.
For other motor makes than Grundfos, contact
Grundfos or the motor manufacturer.

3
3 Stellung
oclock
position

6
6Stellung
oclock
position

9
9Stellung
oclock
position
Standard

Stellung
12
12
oclock
position

TM03 0565 2005

As standard, the terminal boxes of TP and TPE pumps


are mounted in 9 oclock position. The possible
terminal box positions are shown below.

Fig. 63 Possible terminal box positions

Note: Due to the motor construction, the terminal


boxes of some TP pumps with motor sizes above
250 kW are mounted in 10.30 oclock position.
TPD twin-head pumps
As standard, the terminal boxes of all TPD pumps are
mounted in 12 oclock position. See fig. 63.

Electrical installation
The electrical connection should be carried out in
accordance with local regulations.

Mains-operated motors
The operating voltage and frequency are marked on
the pump nameplate. Make sure that the motor is
suitable for the power supply on which it will be used.
Single-phase standard motors incorporate a thermal
switch and require no additional motor protection.
Three-phase motors must be connected to a motor
starter.
Motors of 3 kW and up incorporate thermistors (PTC).
The thermistors are designed according to DIN 44082.
The electrical connection should be carried out as
shown in the diagram inside the terminal box cover.
The motors of twin-head pumps are to be connected
separately.

Installation

17

TP, TPD, TPE

67

18

TP, TPD, TPE

MGE motors

18. MGE motors


MGE motors, 2.2 kW, 2-pole, and 1.1 kW,
4-pole
Three-phase supply voltage
3 x 380-500 V - 10 %/+ 10 %, 50/60 Hz, PE.
Recommended fuse size
Motor size
[kW]

Min.
[A]

Max.
[A]

1.1
2.2

6
6

6
10

Standard as well as quick-blow or slow-blow fuses may


be used.
Leakage current
Motor size
[kW]
1.1 - 2.2
(supply voltage < 400 V)
1.1 - 2.2
(supply voltage > 400 V)

Leakage current
[mA]
< 3.5
<5

The leakage currents are measured in accordance with


EN 61800-5-1:2007.

Inputs/outputs
Ground reference (GND)
All voltages refer to GND.
All currents return to GND.
Absolute maximum voltage and current limits
Exceeding the following electrical limits may result in
severely reduced operating reliability and motor life:
Relay 1:
Maximum contact load: 250 VAC, 2 A or 30 VDC, 2 A.
Relay 2:
Maximum contact load: 30 VDC, 2 A.
GENI terminals: -5.5 - 9.0 VDC or < 25 mADC.
Other input/output terminals: -0.5 - 26 VDC or
< 15 mADC.
Digital inputs (DI)
Internal pull-up current > 10 mA at Vi = 0 VDC.
Internal pull-up to 5 VDC (currentless for Vi > 5 VDC).
Low logic level: Vi < 1.5 VDC.
High logic level: Vi > 3.0 VDC.
Hysteresis: No.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.

68

Open-collector digital outputs (OC)


Current sinking capability: 75 mADC, no current
sourcing.
Load types: Resistive and/or inductive.
Low-state output voltage at 75 mADC: Max. 1.2 VDC.
Low-state output voltage at 10 mADC: Max. 0.6 VDC.
Overcurrent protection: Yes.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
Analog inputs (AI)
Voltage signal ranges:
0.5 - 3.5 VDC, AL AU.
0-5 VDC, AU.
0-10 VDC, AU.
Voltage signal: Ri > 100 k at 25 C.
Leak currents may occur at high operating
temperatures. Keep the source impedance low.
Current signal ranges:
0-20 mADC, AU.
4-20 mADC, AL AU.
Current signal: Ri = 292 .
Current overload protection: Yes. Change to voltage
signal.
Measurement tolerance: - 0/+ 3 % of full scale
(max.-point coverage).
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m (excl. potentiometer).
Potentiometer connected to 5 V, GND, any AI:
Use maximum 10 k.
Maximum cable length: 100 m.
Analog output (AO)
Current sourcing capability only.
Voltage signal:
Range: 0-10 VDC.
Minimum load between AO and GND: 1 k.
Short-circuit protection: Yes.
Current signal:
Ranges: 0-20 and 4-20 mADC.
Maximum load between AO and GND: 500 .
Open-circuit protection: Yes.
Tolerance: - 0/+ 4 % of full scale (max.-point
coverage).
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.

Pt100/1000 inputs (PT)

Sound pressure level

Temperature range:
Minimum -30 C (88 / 882 ).
Maximum 180 C (168 / 1685 ).
Measurement tolerance: 1.5 C.
Measurement resolution: < 0.3 C.
Automatic range detection (Pt100 or Pt1000): Yes.
Sensor fault alarm: Yes.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Use Pt100 for short wires.
Use Pt1000 for long wires.

TPE Series 1000

Grundfos Digital Sensor input and output (GDS)


Use Grundfos Digital Sensor only.

Motor
[kW]

Max. speed
stated on
nameplate
[min-1]

1.1

2000

2.2

4000

Speed
[min-1]

1500
2000
3000
4000

Sound pressure level


ISO 3743
[dB(A)]
1-phase
motors

3-phase
motors
38
42
57
64

The grey fields indicate that the motor is not yet


available in this MGE motor range, but is available in
the previous MGE motor range.

Power supplies (5 V, 24 V)

Motor protection

5 V:

The motor requires no external motor protection.


The motor incorporates thermal protection against
slow overloading and blocking.

Output voltage: 5 VDC - 5 %/+ 5 %.


Maximum current: 50 mADC (sourcing only).
Overload protection: Yes.

Additional protection

24 V:

Three-phase motors

Output voltage: 24 VDC - 5 %/+ 5 %.


Maximum current: 60 mADC (sourcing only).
Overload protection: Yes.

If the motor is connected to an electric installation


where an earth leakage circuit breaker (ELCB) or
ground fault circuit interrupter (GFCI) is used as
additional protection, this circuit breaker or interrupter
must be of the following type:
It must be suitable for handling leakage currents
and cutting-in with short pulse-shaped leakage.
It must trip out when alternating fault currents and
fault currents with DC content, i.e. pulsating DC and
smooth DC fault currents, occur.
For these motors an earth leakage circuit breaker or
ground fault circuit interrupter, type B, must be used.
This circuit breaker or interrupter must be marked with
the following symbols:

Digital outputs (relays)


Potential-free changeover contacts.
Minimum contact load when in use: 5 VDC, 10 mA.
Screened cable: 0.5 - 2.5 mm2 / 28-12 AWG.
Maximum cable length: 500 m.
Bus input
Grundfos GENIbus protocol, RS-485.
Screened 3-core cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
EMC (electromagnetic compatibility)
EN 61800-3.
Residential areas, unlimited distribution,
corresponding to CISPR 11, class B, group 1.
Industrial areas, unlimited distribution, corresponding
to CISPR 11, class A, group 1.
Contact Grundfos for further information.
Enclosure class
Standard: IP55 (IEC 34-5).
Optional: IP66 (IEC 34-5).
Insulation class
F (IEC 85).

MGE motors

18

TP, TPD, TPE

ELCB
(GFCI)

Note: When an earth leakage circuit breaker or ground


fault circuit interrupter is selected, the total leakage
current of all the electrical equipment in the installation
must be taken into account.

Start/stop of pump
The number of starts and stops via the mains voltage
must not exceed four times per hour.
When the pump is switched on via the mains, it will
start after approx. 5 seconds.
If a higher number of starts and stops is desired, the
input for external start/stop must be used when
starting/stopping the pump.
When the pump is started/stopped via an external
on/off switch, it will start immediately.

69

18

TP, TPD, TPE

Connection terminals, standard functional module


(FM 200)

Single-phase supply:

TM05 4034 1912

MGE motors

Wiring diagrams

ELCB
(GFCI)

Fig. 64 Example of a mains-connected motor with mains


switch, backup fuse and additional protection

Three-phase supply:

L1

L3

L1

ELCB
(GFCI)

L2
L3

PE

TM05 3942 1812

L2

Fig. 65 Example of a mains-connected motor with mains


switch, backup fuse and additional protection

Connection terminals
The descriptions and terminal overviews in this section
apply to both single-phase and three-phase motors.
The number of terminals depends on the functional
module (FM). The fitted module can be identified on
the motor nameplate. See fig. 66.

INPUT
:

U in

A I 1/1 :

Made in Hungary
DK - 8850 Bjerringbro, Denmark

TM05 8641 2513

:
f in
I SF Ampp:

VARIANT
Hp PB :
rpm FM :
HMI :
HMI:
CIM :

OUTPUT
VARIANT
P2
P
Hp PB :
:
rpm FM :
V n max:
:
HMI :
Hz Eff
CIM :
A

Xxxxxxxxxxx

P.C. :
Serial no :
Env.Type
Env.Ty
ype
p :
TEFC
SF :
CL:
kg
g Tamb :
F PF:

E.P. Motor

Type
Typ
ype :
P.N. :
DE :
NDE :
Wg
gt :
Wgt

Fig. 66 Identification of functional module

70

The standard module has these connections:


two analog inputs
two digital inputs or one digital input and one
open-collector output
Grundfos Digital Sensor input and output
two signal relay outputs
GENIbus connection.
See fig. 67.
Note: Digital input 1 is factory-set to be the start/stop
input where an open circuit will result in stop. A jumper
has been factory-fitted between terminals 2 and 6.
Remove the jumper if digital input 1 is to be used as
external start/stop or any other external function.
Note: As a precaution, the wires to be connected to
the connection groups below must be separated from
each other by reinforced insulation in their entire
lengths.
Inputs and outputs
All inputs and outputs are internally separated from
the mains-conducting parts by reinforced insulation
and galvanically separated from other circuits.
All control terminals are supplied by safety extra-low
voltage (SELV), thus ensuring protection against
electric shock.
Signal relay outputs
Signal relay 1:
LIVE:
Mains supply voltages up to 250 VAC can be
connected to this output.
SELV:
The output is galvanically separated from other
circuits. Therefore, the supply voltage or safety
extra-low voltage can be connected to the output
as desired.
Signal relay 2:
SELV:
The output is galvanically separated from other
circuits. Therefore, the supply voltage or safety
extra-low voltage can be connected to the output
as desired.
Mains supply (terminals N, PE, L or L1, L2, L3,
PE).
A galvanically safe separation must fulfil the
requirements for reinforced insulation including
creepage distances and clearances specified in EN
61800-5-1.

Terminal
NC
C1
NO
NC
C2
NO

NC

Type

Function

Normally closed
contact
Common
Normally open
contact

Signal relay 1
(LIVE or SELV)

Normally closed
contact
Common
Normally open
contact

Signal relay 2
(SELV only)

10

DI3/OC1

AI1

2
5
6
A
Y
B

DI1
+5 V
GND
GENIbus, A
GENIbus, Y
GENIbus, B

3
15
8
26
23
25
24

GND
+24 V
+24 V
+5 V
GND
GDS TX
GDS RX

AI2

C1
NO
NC
C2

+24 V*

+24 V*/5 V*

+24 V*/5 V*

10

+5 V*

DI3/OC1

AI1

DI1

+5 V

GND

GENIbus A

GENIbus Y

GENIbus B

GND

15

+24 V

+24 V

26

+5 V

23

GND

25

GDS TX

24

GDS RX

AI2

TM05 3510 3512

+24 V*

+24 V*

GND

+24 V*

NO

DI

+24 V*

OC

MGE motors

18

TP, TPD, TPE

Digital input/output, configurable.


Open collector: Max. 24 V resistive or
inductive.
Analog input:
0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V / 0-10 V
Digital input, configurable
Supply to potentiometer and sensor
Ground
GENIbus, A (+)
GENIbus, GND
GENIbus, B (-)
Ground
Supply
Supply
Supply to potentiometer and sensor
Ground
Grundfos Digital Sensor output
Grundfos Digital Sensor input
Analog input:
0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V / 0-10 V

If an external supply source is used, there must be a connection to


GND.

Fig. 67 Connection terminals, FM 200

71

18

TP, TPD, TPE

MGE motors

Connection terminals, advanced functional module


(FM 300)
The advanced functional module is only available as
an option.
The advanced module has these connections:
three analog inputs
one analog output
two dedicated digital inputs
two configurable digital inputs or open-collector
outputs
Grundfos Digital Sensor input and output
two Pt100/1000 inputs
two LiqTec sensor inputs 1)
two signal relay outputs
GENIbus connection.
1) Not applicable for TPE pumps.

See fig. 68.


Note: Digital input 1 is factory-set to be the start/stop
input where an open circuit will result in stop.
A jumper has been factory-fitted between terminals 2
and 6. Remove the jumper if digital input 1 is to be
used as external start/stop or any other external
function.
Note: As a precaution, the wires to be connected to
the connection groups below must be separated from
each other by reinforced insulation in their entire
lengths.
Inputs and outputs
All inputs and outputs are internally separated from
the mains-conducting parts by reinforced insulation
and galvanically separated from other circuits.
All control terminals are supplied by safety extra-low
voltage (SELV), thus ensuring protection against
electric shock.
Signal relay outputs
Signal relay 1:
LIVE:
Mains supply voltages up to 250 VAC can be
connected to this output.
SELV:
The output is galvanically separated from other
circuits. Therefore, the supply voltage or safety
extra-low voltage can be connected to the output
as desired.
Signal relay 2:
SELV:
The output is galvanically separated from other
circuits. Therefore, the supply voltage or safety
extra-low voltage can be connected to the output
as desired.
Mains supply (terminals N, PE, L or L1, L2, L3,
PE).
A galvanically safe separation must fulfil the
requirements for reinforced insulation including
creepage distances and clearances specified in EN
61800-5-1.

72

Terminal

NC

Type

Function

NC
C1
NO

Normally closed contact


Common
Normally open contact

Signal relay 1
(LIVE or SELV)

NC
C2
NO

Normally closed contact


Common
Normally open contact

Signal relay 2
(SELV only)

18

GND

11

DI4/OC2

19
17

Pt100/1000 input 2
Pt100/1000 input 1

12

AO

GND

14

AI3

DI2

21

LiqTec sensor input 1

20

GND

22

LiqTec sensor input 2

10

DI3/OC1

AI1

DI1

+5 V

6
A
Y
B

GND
GENIbus, A
GENIbus, Y
GENIbus, B

3
15
8

GND
+24 V
+24 V

26

+5 V

23

GND

25

GDS TX

24

GDS RX

AI2

C1
NO
NC
C2
NO

+24 V*

+24 V*

+24 V*

+24 V*/5 V*

+24 V*/5 V*

+5 V*

11

DI4/OC2

19

Pt100/1000

17

Pt100/1000

12

AO

GND

14

AI3

DI2

21

LiqTec

20

GND

22

LiqTec

10

GND

DI3/OC1

AI1

DI1

+5 V

GND

GENIbus A

GENIbus Y

GENIbus B

GND

15

+24 V

+24 V

26

+5 V

23

GND

25

GDS TX

24

GDS RX

AI2

TM05 3509 3512

+24 V*

+5 V*

DI

GND

+24 V*

OC

+24 V*/5 V*

+24 V*

18

DI

+24 V*

OC

+24 V*

If an external supply source is used, there must be a connection to


GND.

Fig. 68 Connection terminals, FM 300 (option)

MGE motors

18

TP, TPD, TPE

Ground
Digital input/output,
configurable.
Open collector: Max. 24 V
resistive or inductive.
Pt100/1000 sensor input
Pt100/1000 sensor input
Analog output:
0-20 mA / 4-20 mA
0-10 V
Ground
Analog input:
0-20 mA / 4-20 mA
0-10 V
Digital input, configurable
LiqTec sensor input
(white conductor)
Ground
(brown and black
conductors)
LiqTec sensor input
(blue conductor)
Digital input/output,
configurable.
Open collector: Max. 24 V
resistive or inductive.
Analog input:
0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V / 0-10 V
Digital input, configurable
Supply to potentiometer and
sensor
Ground
GENIbus, A (+)
GENIbus, GND
GENIbus, B (-)
Ground
Supply
Supply
Supply to potentiometer and
sensor*
Ground
Grundfos Digital Sensor
output
Grundfos Digital Sensor
input
Analog input:
0-20 mA / 4-20 mA
0.5 - 3.5 V / 0-5 V / 0-10 V

73

18

TP, TPD, TPE

MGE motors

MGE motors, 1.5 to 18.5 kW, 4-pole,


and 3 to 22 kW, 2-pole

Input/output

The motors offer these features:


Three-phase mains connection.
Three-phase, asynchronous squirrel-cage induction
motors designed to current IEC, DIN and VDE
guidelines and standards. The motors incorporate
frequency converter and PI controller.
Used for continuously variable speed control of
Grundfos E-pumps.
Available in power sizes 1.5 - 18.5 kW, 4-pole, and
3-22 kW, 2-pole.

External potential-free switch.


Voltage: 5 VDC.
Current: < 5 mA.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.

Start/stop

Digital input
External potential-free switch.
Voltage: 5 VDC.
Current: < 5 mA.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.

GR8275

Setpoint signals

Fig. 69 Three-phase MGE motor

Supply voltage
3 x 380-480 V - 10 %/+ 10 %, 50/60 Hz, PE.

Back-up fuse
Motor size
[kW]

Max. fuse
[A]

1.5 - 5.5
7.5
11
15
18.5
22

16
32
26
36
43
51

Standard as well as quick-blow or slow-blow fuses may


be used.

Leakage current
Motor size
[kW]

Leakage current
[mA]

1.5 - 3.0
4.0 - 5.5

< 3.5
<5

5.5, 1400-1800 min-1


7.5
11-22

< 10
> 10

The leakage currents are measured in accordance with


EN 60355-1 for 0.55 to 7.5 kW and EN 61800-5-1 for
11 to 22 kW motors.

Potentiometer
0-10 VDC, 10 k (via internal voltage supply).
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 100 m.
Voltage signal
0-10 VDC, Ri > 50 k.
Tolerance: + 0 %/- 3 % at maximum voltage signal.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
Current signal
DC 0-20 mA / 4-20 mA, Ri = 175 .
Tolerance: + 0 %/- 3 % at maximum current signal.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.

Sensor signals
Voltage signal
0-10 VDC, Ri > 50 k (via internal voltage supply).
Tolerance: + 0 %/- 3 % at maximum voltage signal.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
Current signal
DC 0-20 mA / 4-20 mA, Ri = 175 .
Tolerance: + 0 %/- 3 % at maximum current signal.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.
Power supply to sensor
+24 VDC, max. 40 mA.

Signal output
Potential-free changeover contact.
Maximum contact load: 250 VAC, 2 A.
Minimum contact load: 5 VDC, 10 mA.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.

Bus input
Grundfos GENIbus protocol, RS-485.
Screened cable: 0.5 - 1.5 mm2 / 28-16 AWG.
Maximum cable length: 500 m.

74

18

TP, TPD, TPE

Motor
[kW]
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
15
18.5
22

Emission/immunity

Sound pressure level


Motor
[kW]
1.5

Emission:
The motors may be installed in residential areas (first
environment), unrestricted distribution, corresponding to
CISPR11, group 1, class B.

2.2

Immunity:
The motors fulfil the requirements for both the first and
second environment.

3.0

Emission:
The motors are category C3, corresponding to CISPR11,
group 2, class A, and may be installed in industrial areas
(second environment).
If fitted with an external Grundfos EMC filter, the motors are
category C2, corresponding to CISPR11, group 1, class A,
and may be installed in residential areas (first
environment).

4.0

Note:

When the motors are installed in residential


areas, supplementary measures may be
required as the motors may cause radio
interference.

Immunity:
The motors fulfil the requirements for both the first and
second environment.

For further information about EMC, see EMC and


proper installation, page 78.

5.5

7.5

11

15

Enclosure class
Standard: IP55 (IEC 34-5).
18.5

Insulation class
F (IEC 85).

22

Speed stated on the


nameplate
[min-1]

Sound pressure
level
[dB(A)]

1400-1500
1700-1800
1400-1500
1700-1800
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
1400-1500
1700-1800
2800-3000
3400-3600
2800-3000
3400-3600

53
57
50
52
55
60
65
70
58
63
70
75
52
56
75
80
54
58
65
69
54
59
65
70
54
59
65
70
65
69
69
74
73
78

MGE motors

EMC (electromagnetic compatibility to EN


61800-3)

Ambient temperature
During operation: -20 - +40 C
During storage/transport:
0.25 - 7.5 kW: -40 - +60 C
11 - 22 kW:
-25 - +70 C.

Relative air humidity


Maximum 95 %.

75

18

TP, TPD, TPE

MGE motors

Motor protection

Other connections

The motor requires no external motor protection.


The motor incorporates thermal protection against
slow overloading and blocking (TP 211 to IEC 34-11).

Figure 71 shows the connection terminals of external


potential-free contacts for start/stop and digital
function, external setpoint signal, sensor signal,
GENIbus and relay signal.
Note: If no external on/off switch is connected,
short-circuit terminals 2 and 3 using a short wire.
Note: As a precaution, the wires to be connected to
the connection groups below must be separated from
each other by reinforced insulation in their entire
lengths.
Group 1: Inputs (external start/stop, digital
function, setpoint and sensor signals, terminals 1-9,
and bus connection, terminals B, Y, A).
All inputs (group 1) are internally separated from the
mains-conducting parts by reinforced insulation and
galvanically separated from other circuits. All control
terminals are supplied by protective extra-low
voltage (PELV), thus ensuring protection against
electric shock.
Group 2: Output (relay signal, terminals NC, C,
NO).
The output (group 2) is galvanically separated from
other circuits. A maximum supply voltage of 250 V
or protective extra-low voltage can be connected to
the output as desired.
Group 3: Mains supply (terminals L1, L2, L3, PE).
A galvanically safe separation must fulfil the
requirements for reinforced insulation including
creepage distances and clearances specified in EN
60335.

Additional protection
If the motor is connected to an electric installation
where an earth leakage circuit breaker is used as
additional protection, this circuit breaker must fulfil the
following:
It is suitable for handling leakage currents and
cutting-in in case of short pulse-shaped leakage.
It trips out when alternating fault currents and fault
currents with DC content, i.e. pulsating DC and
smooth DC fault currents, occur.
For these pumps, an earth leakage circuit breaker type
B must be used.
This circuit breaker must be marked with the following
symbols:
ELCB

Note: When an earth leakage circuit breaker is


selected, the total leakage current of all the electrical
equipment in the installation must be taken into
account.

Start/stop of pump

Group 3

Group 2

The number of starts and stops via the mains voltage


must not exceed four times per hour.
When the pump is switched on via the mains, it will
start after approx. 5 seconds.
If a higher number of starts and stops is desired, the
input for external start/stop must be used when
starting/stopping the pump.
When the pump is started/stopped via an external
on/off switch, it will start immediately.

NC C NO

L1 L2 L3

Wiring diagram, 0.55 - 7.5 kW


3 x 380-480 V - 10 %/+ 10 %, 50/60 Hz
External switch
Max. 16/32 A
L1

L2
L3

PE

0-10 V
0/4-20 mA

4-20 mA

1/0

1 9 8 7

B Y A

STOP

6:
5:
4:
3:
2:

RUN
0/4-20 mA

0-10 V

10K

6 5 4 3 2

Fig. 71 Connection terminals

76

GND (frame)
+10 V
Setpoint input
GND (frame)
Start/stop

Group 1

Fig. 70 Wiring diagram, three-phase MGE motors,


0.75 - 7.5 kW

1: Digital input
9: GND (frame)
8: +24 V
7: Sensor input
B: RS-485B
Y: Screen
A: RS-485A

TM02 8414 5103

L3

L1

ELCB

TM00 9270 4696

L2

18

TP, TPD, TPE

Group 3

Group 2

3 x 380-480 V - 10 %/+ 10 %, 50/60 Hz

MGE motors

Wiring diagram, 11-22 kW

External switch
Max. 26/51 A
L1

L1

ELCB

L3

L2
L3

PE

TM00 9270 4696

L2

Fig. 72 Wiring diagram, three-phase MGE motors,


11-22 kW

Other connections

Start/stop, terminals 2 and 3


digital input, terminals 1 and 9
setpoint input, terminals 4, 5 and 6
sensor input, terminals 7 and 8
GENIbus, terminals B, Y and A.
All inputs (group 1) are internally separated from the
mains-conducting parts by reinforced insulation and
galvanically separated from other circuits.
All control terminals are supplied by protective
extra-low voltage (PELV), thus ensuring protection
against electric shock.
Group 2: Output (relay signal, terminals NC, C,
NO).
The output (group 2) is galvanically separated from
other circuits. Therefore, the supply voltage or
protective extra-low voltage can be connected to the
output as desired.
Group 3: Mains supply (terminals L1, L2, L3).
A galvanically safe separation must fulfil the
requirements for reinforced insulation including
creepage distances and clearances specified in
EN 61800-5-1.

6: GND (frame)
5: +10 V
4: Setpoint input
3: GND (frame)
2: Start/stop

Group 1

Group 1: Inputs

1: Digital input
9: GND (frame)
8: +24 V
7: Sensor input
B: RS-485B
Y: Screen
A: RS-485A

TM03 8608 2007

Note: As a precaution, the wires to be connected to


the connection groups below must be separated from
each other by reinforced insulation in their entire
lengths.

Fig. 73 Connection terminals

77

19

TP, TPD, TPE

EMC

19. EMC
EMC and proper installation

Where can E-pumps be installed?

General information

All E-pumps with MGE motors can be used in both


residential areas (first environment) and industrial
areas (second environment) within certain limitations.

The growing use of electric/electronic controls and


electronic equipment including PLCs and computers
within all business areas require these products to fulfil
the existing standards within EMC (ElectoMagnetic
Compatibility). The equipment must be mounted
properly.
This section deals with these issues.

What is EMC?
ElectoMagnetic Compatibility is the ability of an electric
or electronic device to function in a given
electromagnetic environment without disturbing the
surroundings and without being disturbed by other
devices in the surroundings. EMC is normally split into
emission and immunity.

What is meant by the first and the second


environment?
The first environment (residential areas) includes
establishments directly connected to a low-voltage
power supply network which supplies domestic
buildings.
The second environment (industrial areas) includes
establishments which are not connected to a
low-voltage network that supplies domestic buildings.
The level of electromagnetic disturbance can be
expected to be much higher than in the first
environment.
EMC and C-tick

Emission
Emission is defined as the electric or electromagnetic
noise emitted by a device during operation and which
can reduce the function of other devices or disturb
various wireless communications, including radio/TV.

Immunity
Immunity deals with a device's ability to function in
spite of the presence of electric or electromagnetic
noise, such as sparking noise from contactors or
high-frequency fields from various transmitters, mobile
phones, etc.

E-pumps and EMC


All Grundfos E-pumps are CE- and C-tick-marked
indicating that the product is designed to meet the
EMC requirements defined by the EU (European
Union) and Australia/New Zealand.
EMC and CE
All E-pumps fulfil the EMC directive 2004/108/EC and
are tested according to standard EN 61800-3.
All E-pumps are fitted with a radio interference filter
and varistors in the mains supply input to protect the
electronics against voltage peaks and noise present in
the mains supply (immunity). At the same time, the
filter will limit the amount of electrical noise which the
E-pump emits to the mains supply network (emission).
All remaining inputs included in the electronic unit will
also be protected against peaks and noise which can
damage or disturb the function of the unit.
On top of that, the mechanical and electronic designs
are made in such a way that the unit can operate
sufficiently under a certain level of radiated
electromagnetic disturbance.
The limits which the E-pumps are tested against are
listed in standard EN 61800-3.

78

All E-pumps marked with the C-tick logo fulfil the


requirements for EMC in Australia and New Zealand.
The C-tick approval is based on the EN standards, and
the units are therefore tested according to the
European standard EN 61800-3.
Only E-pumps with MGE-motors are marked with
C-tick.
The C-tick only covers emission.

EMC and proper installation


With the CE and C-tick marks, the E-pumps live up to
and have been tested to meet specific EMC
requirements. This, however, does not mean that
E-pumps are immune to all the sources of noise to
which they can be exposed in practice. In some
installations, the impact may exceed the level to which
the product is designed and tested.
Furthermore, unproblematic operation in a noisy
environment presupposes that the installation of the
E-pump is made properly.
Below you will find a description of a correct E-pump
installation.

Connection of mains supply in MGE


Practice shows that large cable loops are often made
inside the terminal box to get some "spare cable".
Of course, this can be useful. However, with regard to
EMC it is a poor solution as these cable loops will
function as antennas inside the terminal box.
To avoid EMC problems, the mains supply cable and
its individual conductors in the terminal box of the
E-pump must be as short as possible. If required,
spare cable can be established outside the E-pump.

20

TP, TPD, TPE

Flanges for TP pumps

20. Flanges for TP pumps


Flange dimensions
PN 6 and PN 10 flanges
EN 1092-2 PN 6 (0.6 MPa)

D1

EN 1092-2 PN 10 (1.0 MPa)


Nominal diameter (DN)

Nominal diameter (DN)

TM02 7720 3803

32

D2
D3

40

50

65

80

100

32

40

50

65

80

100

125

150

200

250

D1

32

40

50

65

80

100

32

40

50

65

80

100

125

150

200

250

D2

90

100

110

130

150

170

100

110

125

145

160

180

210

240

295

350
395

D3

120

130

140

160

190

210

140

150

165

185

200

220

250

285

340

4x14

4x14

4x14

4x14

4x19

4x19

4x19

4x19

4x19

4x19

8x19

8x19

8x19

8x23

8x23 12x23

PN 16 and PN 25 flanges
EN 1092-2 PN 16 (1.6 MPa)

D1

EN 1092-2 PN 25 (2.5 MPa)

Nominal diameter (DN)

TM02 7720 3803

32

D2
D3

40

50

65

80

100

Nominal diameter (DN)


125

150

200

100

125

150

200

250

300

350

D1

32

40

50

65

80

100

125

150

200

100

125

150

200

250

300

350

D2

100

110

125

145

160

180

210

240

295

190

220

250

310

370

430

490

340

360

425

485

555

D3

140

150

165

185

200

220

250

285

4x19

4x19

4x19

4x19

8x19

8x19

8x19

8x23 12x23

235

270

300

8x23

8x28

8x28 12x28 12x31 16x31 16x34

PN 40 flanges
EN/DIN 2635 PN 40
(4.0 MPa)

D1

D2
D3

TM02 7720 3803

Nominal diameter (DN)


400

500

D1

400

500

D2

585

585

D3

660

660

16x42

20x42

79

21

TP, TPD, TPE

Curve charts

21. Curve charts


How to read the curve charts
H
[m]
110

TP, TPE 50

-1050/2

60 Hz

100
-880/2

90

QH curve for the individual single-head pump.


The bold curve indicates the recommended
performance range.

-790/2

80

Pump type and frequency

-720/2

70
60
50
40
30
20
P2
[kW]

10

20

30

40

50

60

70

80 Q [m/h]

28

-1050/2

24
-880/2
-790/2

20
16

The power curve indicates pump input


power [P2].

-720/2

12
8
4
0
0
NPSH
[m]
14

10

20

30

40

50

60

70

80 Q [m/h]

The NPSH (3 %) curve shows the required net


positive suction head (NPSH) to ensure that the
pump head is not reduced by more than 3 %.
The available system pressure at the pump inlet
must be according to the NPSH (3 %) curve + a
safety margin of at least 0.5 m.

12
10
8
6
4
2
0
Eta
[%]
65

10

20

30

40

50

60

70

80 Q [m/h]

60

-1050/2

-720/2

55

-790/2 -880/2

50

The eta curve shows the pump efficiency.

45
40
35
0
0
0

80

10

20

30

5
2

40

50

10
4

60

15
6

70

80 Q [m/h]

20
8

Q [l/s]
10

v [m/s]

TM02 5039 0504

30

TP, TPD, TPE

21
Curve charts

Curve conditions
The guidelines below apply to the curves shown on the
following pages:
1. Tolerances to ISO 9906:2012 Grade 3B.
2. The curves apply to the performance of
single-head, three-phase pumps. For other pump
versions, please see the exact curves in WinCAPS
or WebCAPS. For other pump versions, the
performance may differ for the following reasons:
- The valve in twin-head pumps may cause losses.
Note: Grundfos does not recommend continuous
parallel operation of twin-head pumps due to the
increased flow in the pump. An excessive flow
results in noisy operation, increased wear of the
impeller due to cavitation, etc.
3. QH curves of the individual single-head pumps are
shown with expected speed of a three-phase
mains-operated motor. For further information, see
the tables of technical data on the following pages.
4. Curves of TPE Series 1000 pumps are shown as
max. curves (100 % curves) only. Please refer to
WinCAPS for the exact curves.
5. Measurements have been made with airless water
at a temperature of 20 C.
6. The curves apply to a kinematic viscosity of
= 1 mm2/s (1 cSt).
7. Due to the risk of overheating, the pump must not
run constantly below the minimum flow rate
indicated by the bold curves.
8. If the pumped liquid density and/or viscosity are
higher than those of water, it may be necessary to
use a motor with a higher performance.

81

22
DN 32
2-pole, PN 6, 10, 16

Performance curves/technical data

22. Performance curves/technical data


TP, TPD, TPE 2-pole, PN 6, 10, 16
TP, TPD, TPE 32-XX/2
H
[m]

H
[m]

TP 32

-330/2

32

TP, TPE 32

90

60 Hz

80

28
24

-260/2

70

-680/2

20

-220
/2

60

-550/2

16

-160/2

50

-450/2

40

12
-80/2

-360/2
-300/2

30
20

10

0
P2
[kW]

60 Hz

-820/2

10

12

14 Q [m/h]

P2
[kW]

-330/2

1.2

12

16

20

24

28

-820/2

10

1.0

-680/2

-260/2

0.8

0.6

-550/2

-160/2

-220/2

-450/2
-360/2
-300/2

0.4

-80/2

0.2

32 Q [m/h]

0.0
0
NPSH
[m]

10

12

14 Q [m/h]
-160/2

-220/2, -260/2, -330/2

10

12

16

20

24

28

32 Q [m/h]

12

16

20

24

28

32 Q [m/h]

NPSH
[m]
14
12

10
-80/2

8
6

4
2

2
0

0
0

10

12

14 Q [m/h]

Eta
[%]

Eta
[%]

70

50

60

45

-550/2 -680/2 -820/2


-450/2
-360/2

-300/2

-260/2

50

40

-80/2
-160/2

-330/2

40

35

-220/2

30

30

10

12

14 Q [m/h]

Q [l/s]

v [m/s]

0
TM02 5034 4810

12

16

20

24

28

32 Q [m/h]

Q [l/s]

v [m/s]

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

82

TM02 5035 0504

25

20

22
DN 32

Performance curves/technical data

2-pole, PN 6, 10, 16

B4

B4
AC

P
B3

H4

D1
B2

B1

TM02 8632 5004 - TM02 8631 5004

H1

H2

H3

AD

L1
M

AE

AF

AF

C1

AE

M
C6

C5

Technical data
TP 32

-80/2

-160/2

-220/2

-260/2

-330/2

-300/2

-360/2

-450/2

-550/2

-680/2

-820/2

TPD

TPE

TPED

Series

200

200

200

200

200

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

71

71

80

90

90

90

100

112

132

132

160

1~ TPE

3~ TPE

90

100

112

132

132

160

-/0.37

-/0.55

-/0.75

-/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

-/11

-/-

-/-

-/-

-/-

-/-

-/2.2

-/3

-/4

-/5.5

-/7.5

-/11

PN6/10

PN6/10

PN6/10

PN6/10

PN6/10

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN
Tmin;Tmax

[C] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]

D1
AC
AD

1~/3~ TP

[mm]

32

32

32

32

32

32

32

32

32

32

32

[mm]

-/142

-/142

-/142

-/142

-/178

-/178

-/198

-/220

-/220

-/260

-/314

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/-

-/-

-/-

-/-

-/-

-/122

-/198

-/220

-/220

-/260

-/314

-/109

-/109

-/109

-/109

-/110

-/167

-/120

-/134

-/134

-/159

-/204

1~/3~ TPE [mm]

-/-

-/-

-/-

-/-

-/-

-/158

-/177

-/188

-/188

-/213

-/308

AE

1~/3~ TPE [mm]

132

132

145

145

145

210

AF

1~/3~ TPE [mm]

132

132

145

145

145

210

[mm]

200

250

250

300

300

350

B1

[mm]

75/-

75/-

102/-

102/-

102/-

144/321 144/321 144/321 144/321 144/321 144/321

B2

[mm]

75/-

75/-

102/-

102/-

102/-

144/321 144/321 144/321 144/321 144/321 144/321

B3

[mm]

[mm]

109/-

109/-

109/-

109/-

110/-

B4

TP
TPE

355

355

355

355

355

355

144/321 144/321 144/321 150/328 159/328 204/353

[mm]

-/-

-/-

-/-

-/-

-/-

[mm]

80/-

80/-

80/-

80/-

80/-

144/435 144/435 144/435 144/435 144/435 144/435

C5

[mm]

110

110

140

140

140

220/46

220/46

220/46

220/46

220/46

C6

[mm]

175

175

175

175

175

175

L1

[mm]

220

220

280

280

280

440

440

440

440

440

440

H1

[mm]

68

68

79

79

79

100

100

100

100

100

100

H2

[mm]

125

125

137

137

147

156

184

184

223

223

253

[mm]

-/395

-/395

-/447

-/517

-/507

-/577

-/619

-/656

-/714

-/702

-/824

-/-

-/-

-/-

-/-

-/-

-/530

-/619

-/656

-/714

-/702

-/824

C1

H3

1~/3~ TP

1~/3~ TPE [mm]

167/-

177/-

188/-

188/-

213/-

308/220/46

H4

[mm]

35

[mm]

M12

M12

M12

M12

M12

M16

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

83

22
DN 40
2-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 40-XX/2


H
[m]

H
[m]
40
36

-390/2

TP, TPE 40

-330/2

60 Hz

TP, TPE 40

100

-930/2

90

-850/2

32

80

-270/2

28

-740/2

70

24
-240/2

20
16
12

60

-550/2

-160/2

50

-450/2

-80/2

40

-370/2

30

4
0
P2
[kW]

60 Hz

20
0

10 12 14 16 18

Q [m/h]

P2
[kW]
16

2.4
2.0

-390/2

14

-330/2

12

1.6

10

15

20

25

30

35 40

-930/2
-850/2
-740/2

10
-270/2

1.2

-240/2

-160/2
-80/2

0.4

-550/2
-450/2
-370/2

0.8

Q [m/h]

0.0

0
NPSH
[m]

10 12 14 16 18

Q [m/h]

10

15

20

25

30

35 40

Q [m/h]

10

15

20

25

30

35 40

Q [m/h]

NPSH
[m]
-270/2, -330/2, -390/2

10

10

-240/2

-160/2

-80/2

0
0

10 12 14 16 18

Q [m/h]

Eta
[%]
55

Eta
[%]
80

-240/2

70

-740/2 -850/2

45

60

40

-160/2

50

-370/2
-550/2

35

-80/2
-330/2 -390/2
-270/2

30

40

25

30

20

10 12 14 16 18

2
1

3
2

4
3

Q [m/h]
Q [l/s]
4 v [m/s]

0
0

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

10
2

15

20

4
2

6
4

25

30
8
6

35 40
10

Q [m/h]
12

Q [l/s]
v [m/s]

TM02 5037 0504

TM02 5036 4810

84

-930/2

-450/2

50

22
DN 40

Performance curves/technical data

2-pole, PN 6, 10, 16

B4

B4
AC

P
B3

H4

D1
B2

B1

TM02 8632 5004 - TM02 8631 5004

H1

H2

H3

AD

L1
M

AE

AF

AF

C1

AE

M
C6

C5

Technical data
TP 40

-80/2

-160/2

-240/2

-270/2

-330/2

-390/2

-370/2

-450/2

-550/2

-740/2

-850/2

-930/2

TPD

TPE

TPED

Series

200

200

200

200

200

200

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

71

80

90

90

90

100

112

132

132

160

160

160

1~ TPE

3~ TPE

112

132

132

160

160

160

-/0.55

-/0.75

-/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/-

-/-

-/-

-/-

-/-

-/-

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

PN 6/10

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN
Tmin;Tmax

[C] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]

D1

[mm]

40

40

40

40

40

40

40

40

40

40

40

40

[mm]

-/142

-/142

-/142

-/178

-/178

-/178

-/220

-/220

-/260

-/314

-/314

-/314

AC
AD

1~/3~ TP

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/-

-/-

-/-

-/-

-/-

-/-

-/220

-/220

-/260

-/314

-/314

-/314

-/109

-/109

-/109

-/110

-/110

-/110

-/134

-/134

-/159

-/204

-/204

-/204

1~/3~ TPE [mm]

-/-

-/-

-/-

-/-

-/-

-/-

-/188

-/188

-/213

-/308

-/308

-/308

AE

1~/3~ TPE [mm]

145

145

145

210

210

210

AF

1~/3~ TPE [mm]

145

145

145

210

210

210

[mm]

250

300

300

350

350

350

B1

[mm]

85/-

75/-

101/-

102/-

102/-

102/-

149/325 149/325 149/325 149/325 149/325 149/325

B2

[mm]

75/-

75/-

101/-

102/-

102/-

102/-

144/321 144/321 144/321 144/321 144/321 144/321

B3

[mm]

[mm]

109/-

109/-

109/-

110/-

110/-

110/-

B4

TP
TPE

355

355

355

355

355

355

149/325 150/328 159/328 204/353 204/353 204/353

[mm]

-/-

-/-

-/-

-/-

-/-

-/-

[mm]

120/-

80/-

80/-

120/-

120/-

120/-

144/435 144/435 144/435 144/435 144/435 144/435

C5

[mm]

125

125

125

160

160

160

220/108 220/108 220/108 220/108 220/108 220/108

C6

[mm]

175

175

175

175

175

175

L1

[mm]

250

250

250

320

320

320

440

440

440

440

440

440

H1

[mm]

67

67

68

68

68

68

110

110

110

110

110

110

H2

[mm]

132

139

144

150

150

160

186

225

225

255

255

255

[mm]

-/390

-/437

-/513

-/500

-/540

-/564

-/668

-/726

-/714

-/836

-/836

-/880

-/-

-/-

-/-

-/-

-/-

-/-

-/668

-/726

-/714

-/836

-/836

-/880

C1

H3

1~/3~ TP

1~/3~ TPE [mm]

188/-

188/-

213/-

308/-

308/-

308/-

H4

[mm]

35

35

35

[mm]

M12

M12

M12

M12

M12

M12

M16

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

85

22
DN 50
2-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 50-XX/2


H
[m]

TP, TPE 50

-410/2

40

60 Hz

-350/2

35

-300/2

30

-250/2

25
20

-240/2

15

-160/2
-80/2

10
5
0
P2
[kW]

10

15

20

25

30

35

40 Q [m/h]

-410/2

-350/2

-300/2
-250/2

-240/2
-160/2

1
-80/2

0
0
NPSH
[m]

10

15

20

25

30

10

35

40 Q [m/h]

-240/2

8
-80/2

-160/2

6
4
2

-250/2, 300/2, 350/2, 410/2

0
0

10

15

20

25

30

35

40 Q [m/h]

-240/2
-300/2

-410/2
-350/2
-80/2

-250/2

-160/2

0
0
0

10
2
1

15
4

20

25

6
2

30
8

35

40 Q [m/h]

10
4

Q [l/s]
5

v [m/s]

TM02 5038 4810

Eta
[%]
75
70
65
60
55
50
45
40
35
30

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

86

22
DN 50

Performance curves/technical data

2-pole, PN 6, 10, 16

B4

B4
AC

P
B3

L1
M

AE

AF

AF

C1

AE

M
C6

C5

TM02 8632 5004 - TM02 8631 5004

D1
B2

B1

H4

H1

H2

H3

AD

Technical data
TP 50

-80/2

-160/2

-240/2

-250/2

-300/2

-350/2

-410/2

TPD

TPE

TPED

Series

200

200

200

300

300

300

300

IEC size

P2

1~ TP

3~ TP

71

90

90

90

100

112

132

1~ TPE

3~ TPE

90

100

112

132

-/0.55

-/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

-/-

-/-

-/-

-/2.2

-/3

-/4

-/5.5

PN6/10

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN
Tmin;Tmax

[C] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120]

D1
AC
AD

1~/3~ TP

[mm]

50

50

50

50

50

50

50

[mm]

-/142

-/142

-/175

-/178

-/198

-/220

-/220

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/-

-/-

-/-

-/122

-/198

-/220

-/220

-/109

-/109

-/110

-/110

-/120

-/134

-/134

1~/3~ TPE [mm]

-/-

-/-

-/-

-/158

-/177

-/188

-/188

AE

1~/3~ TPE [mm]

132

132

145

145

AF

1~/3~ TPE [mm]

132

132

145

145

[mm]

200

250

250

300

B1

[mm]

95/-

100/-

100/-

117/252 117/252 133/290 133/290

B2

[mm]

83/-

100/-

100/-

117/252 117/252 119/284 119/284

B3

[mm]

[mm]

109/-

109/-

110/-

B4

TP
TPE

270

270

320

320

117/252 125/260 134/290 150/310

[mm]

-/-

-/-

-/-

[mm]

120/-

120/-

120/-

C5

[mm]

140

140

140

170/60

170/60

170/52

C6

[mm]

175

175

175

175

L1

[mm]

280

280

280

340

340

340

340

H1

[mm]

75

75

75

115

115

115

115

H2

[mm]

137

135

145

152

180

189

228

[mm]

-/403

-/511

-/501

-/588

-/630

-/676

-/734

-/-

-/-

-/-

-/541

-/630

-/676

-/734

C1

H3

1~/3~ TP

1~/3~ TPE [mm]

167/-

177/-

188/-

188/-

144/350 144/350 144/400 144/400


170/52

H4

[mm]

[mm]

M12

M12

M12

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

87

22
DN 50
2-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 50-XX/2


H
[m]
110

TP, TPE 50

-1050/2

60 Hz

100
-880/2

90

-790/2

80

-720/2

70
60
50
40
30
20
P2
[kW]

10

20

30

40

50

60

70

80 Q [m/h]

28

-1050/2

24
-880/2
-790/2
-720/2

20
16
12
8
4
0
0
NPSH
[m]
14

10

20

30

40

50

60

70

80 Q [m/h]

10

20

30

40

50

60

70

80 Q [m/h]

12
10
8
6
4
2
0
Eta
[%]
65

60

-1050/2

-720/2

55

-790/2 -880/2

50
45
40
35
30

0
0

10

20

30

5
2

40

50

10
4

60

15
6

70

80 Q [m/h]

20
8

Q [l/s]
10

v [m/s]

TM02 5039 4912

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

88

22
DN 50

Performance curves/technical data

2-pole, PN 6, 10, 16

B4

B4
AC

P
B3

D1
B2

L1
M

AF

AE

AF

C1

AE

M
C6

C5

TM02 8632 5004 - TM02 8631 5004

B1

H4

H1

H2

H3

AD

Technical data
TP 50

-720/2

-790/2

-880/2

-1050/2

TPD

TPE

TPED

Series

300

300

300

300

IEC size

P2

1~ TP

3~ TP

160

160

180

200

1~ TPE

3~ TPE

160

160

180

-/30

1~/3~ TP

[kW]

-/15

-/18.5

-/22

1~/3~ TPE [kW]

-/15

-/18.5

-/22

-/-

PN 16

PN 16

PN 16

PN 16

PN
Tmin;Tmax

[C] [-25;120] [-25;120] [-25;120] [-25;120]

D1

[mm]

50

50

50

50

[mm]

-/314

-/314

-/314

-/396

1~/3~ TPE [mm]

-/314

-/314

-/314

-/-

1~/3~ TP

[mm]

-/204

-/204

-/204

-/315

AC
AD

1~/3~ TP

1~/3~ TPE [mm]

-/308

-/308

-/308

-/-

AE

1~/3~ TPE [mm]

210

210

210

AF

1~/3~ TPE [mm]

210

210

210

[mm]

350

350

350

400

B1

[mm] 180/386 180/386 180/386 180/386

B2

[mm] 164/379 164/379 164/379 164/379

B3

[mm]

B4

420

420

420

420

TP

[mm] 204/386 204/386 204/386 300/411

TPE

[mm]

C1

308/-

308/-

308/-

-/-

[mm] 144/500 144/500 144/500 144/500

C5

[mm] 220/123 220/123 220/123 220/123

C6

[mm]

175

175

175

L1

[mm]

440

440

440

440

H1

[mm]

115

115

115

115

H2
H3

175

[mm]

264

264

264

264

[mm]

-/850

-/894

-/894

-/942

1~/3~ TPE [mm]

1~/3~ TP

-/850

-/894

-/920

-/-

H4

[mm]

35

35

35

35

[mm]

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

89

22
DN 65
2-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 65-XX/2


H
[m]

TP, TPE 65

-390-2

40

60 Hz

35

-340/2

30
-260/2

25

-220/2

20
-160/2

15

-80/2

10

-240/2

5
0
P2
[kW]
8

10

20

30

40

50

60

Q [m/h]

-390/2

7
6

-340/2

5
4

-260/2

-220/2
-240/2
-160/2

2
1

-80/2

0
0
NPSH
[m]

10

20

30

40

10

50

60

Q [m/h]

-160/2

8
-240/2

6
4

-80/2

2
-220/2, -260/2, -340/2, -390/2

0
0
Eta
[%]
75

10

20

30

40

50

60

Q [m/h]

-160/2

70
65

-340/2
-390/2

60

-80/2

55

-220/2

-260/2

50
45

-240/2

40
35
10

20

0
0

30

5
1

40
10

50

60
15

Q [m/h]
Q [l/s]
5 v [m/s]

TM02 5040 4810

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

90

22
DN 65

Performance curves/technical data

2-pole, PN 6, 10, 16

B4

B4
AC

P
B3

L1
M

AE

AF

AF

C1

AE

M
C6

C5

TM02 8632 5004 - TM02 8631 5004

D1
B2

B1

H4

H1

H2

H3

AD

Technical data
TP 65

-80/2

-160/2

-240/2

-220/2

-260/2

-340/2

-390/2

TPD

TPE

TPED

Series

200

200

200

300

300

300

300

IEC size

P2

1~ TP

3~ TP

90

90

90

100

112

132

132

1~ TPE

3~ TPE

100

112

132

132

-/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

-/-

-/-

-/-

-/3

-/4

-/5.5

-/7.5

PN6/10

PN6/10

PN6/10

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN
Tmin;Tmax

[C] [-25;140] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120]

D1

[mm]

65

65

65

65

65

65

65

[mm]

-/142

-/175

-/175

-/198

-/220

-/220

-/260

AC
AD

1~/3~ TP

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/-

-/-

-/-

-/198

-/220

-/220

-/260

-/109

-/110

-/110

-/120

-/134

-/134

-/159

1~/3~ TPE [mm]

-/-

-/-

-/-

-/177

-/188

-/188

-/213

AE

1~/3~ TPE [mm]

132

145

145

145

AF

1~/3~ TPE [mm]

132

145

145

145

[mm]

250

250

300

300

B1

[mm]

93/-

100/-

100/-

142/298 142/298 142/298 142/298

B2

[mm]

93/-

100/-

100/-

124/290 124/290 124/290 124/290

B3

[mm]

[mm]

109/-

110/-

110/-

B4

TP
TPE

320

320

320

320

142/298 142/298 150/310 159/310

[mm]

-/-

-/-

-/-

[mm]

120/-

120/-

120/-

C5

[mm]

170

170

170

180/65

180/65

180/65

C6

[mm]

175

175

175

175

L1

[mm]

340

340

340

360

360

360

360

H1

[mm]

82

82

82

105

105

105

105

H2

[mm]

156

154

154

201

201

239

239

[mm]

-/539

-/517

-/557

-/641

-/678

-/735

-/723

-/-

-/-

-/-

-//641

-//678

-/735

-/723

C1

H3

1~/3~ TP

1~/3~ TPE [mm]

177/-

188/-

188/-

213/-

144/400 144/400 144/400 144/400


180/65

H4

[mm]

[mm]

M12

M12

M12

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

91

22
DN 65
2-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 65-XX/2


H
[m]
110

TP, TPE 65

-1050/2

60 Hz

100
-910/2

90
80

-740/2

70

-630/2

60

-540/2

50

-480/2

-920/2

40
30
P2
[kW]
40

20

40

60

80

100

Q [m/h]

-1050/2
-920/2
-910/2

35
30
25

-740/2

20

-630/2
-540/2
-480/2

15
10
5
0
0
NPSH
[m]

20

40

60

80

100

Q [m/h]

20

40

60

80

100

Q [m/h]

10
8
6
4
2
0
Eta
[%]
70

-910/2

65

-1050/2
-740/2

60

-630/2

-480/2

55

-920/2

-540/2

50
45
40
35
20

40

0
0

60

10
2

80
20

100

Q [m/h]

30

Q [l/s]

v [m/s]

TM02 5041 3213

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

92

22
DN 65

Performance curves/technical data

2-pole, PN 6, 10, 16

B4

B4
AC

P
B3

D1
B2

H4

B1

TM02 8632 5004 - TM02 8631 5004

H1

H2

H3

AD

L1
M

AF

AE

AF

C1

AE

M
C6

C5

Technical data
TP 65

-480/2

-540/2

-630/2

-740/2

-910/2

-920/2

-1050/2

TPD

TPE

TPED

Series

300

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

160

160

160

180

200

200

200

1~ TPE

3~ TPE

160

160

160

180

-/37

1~/3~ TP

[kW]

-/11

-/15

-/18.5

-/22

-/30

-/37

1~/3~ TPE

[kW]

-/11

-/15

-/18.5

-/22

-/-

-/-

-/-

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16
[-25;120]

PN
Tmin;Tmax

[C]

[-25;120]

[-25;120]

[-25;120]

[-25;120]

[-25;120]

[-25;120]

D1

[mm]

65

65

65

65

65

65

65

1~/3~ TP

[mm]

-/314

-/314

-/314

-/314

-/396

-/407

-/396

1~/3~ TPE

[mm]

-/314

-/314

-/314

-/314

-/-

-/-

-/-

1~/3~ TP

[mm]

-/204

-/204

-/204

-/204

-/315

-/315

-/315

AC
AD

1~/3~ TPE

[mm]

-/308

-/308

-/308

-/308

-/-

-/-

-/-

AE

1~/3~ TPE

[mm]

210

210

210

210

AF

1~/3~ TPE

[mm]

210

210

210

210

[mm]

350

350

350

350

400

400

400

B1

[mm]

178/349

178/349

178/349

178/349

178/349

178/349

178/349

B2

[mm]

164/383

164/383

164/383

164/383

164/383

164/383

164/383

B3

[mm]

440

440

440

440

440

440

440

TP

[mm]

204/395

204/395

204/395

204/395

300/421

315/395

300/421

TPE

[mm]

308/-

308/-

308/-

308/-

-/-

-/-

-/-

[mm]

144/520

144/520

144/520

144/520

144/520

144/520

144/520

C5

[mm]

238/111

238/111

238/111

238/111

238/111

238/111

238/111

C6

[mm]

175

175

175

175

175

175

175

L1

[mm]

475

475

475

475

475

475

475

H1

[mm]

125

125

125

125

125

125

125

B4
C1

H2
H3

[mm]

263

263

263

263

263

263

263

1~/3~ TP

[mm]

-/859

-/859

-/903

-/903

-/951

-/999

-/976

1~/3~ TPE

[mm]

-/859

-/859

-/903

-/929

-/-

-/-

-/-

H4

[mm]

35

35

35

35

35

35

35

[mm]

M16

M16

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

93

22
DN 80
2-pole, PN 6, 10, 16

H
[m]

H
[m]

TP, TPE 80

32

-290/2

60 Hz

28

-750/2

70

-640/2

60

20

-200/2

16

-160/2

-530/2
-480/2

50

-400/2

40

12

-330/2

30

20

4
0

10
0

10 20 30 40 50 60 70 80

Q [m/h]

P2
[kW]
36

-290/2

20

40

60

80 100 120 140

Q [m/h]
-750/2

32

-640/2

28

-240/2

24

16

-400/2

12

-160/2

-530/2
-480/2

20

-200/2

-330/2

4
0

10 20 30 40 50 60 70 80

NPSH
[m]
12

Q [m/h]

20

40

60

80 100 120 140 160Q [m/h]

NPSH
[m]
12

-160/2

10

10

-200/2

8
-240/2, -290/2

-330/2, -400/2
-480/2, -530/2, -640/2, -750/2

0
0

10 20 30 40 50 60 70 80

Q [m/h]

Eta
[%]
75

20

40

60

80 100 120 140

Q [m/h]

Eta
[%]
80

70
65

-640/2

70

-530/2
-400/2
-480/2

-330/2

65

-200/2

55

-750/2

75

-290/2
-240/2

60

60

-160/2

50

55

45

50

40

45
10 20 30 40 50 60 70 80

Q [m/h]

10

15

20

25 Q [l/s]

5 v [m/s]

0
TM02 5042 1604

20

40

60

80 100 120 140 160Q [m/h]

10

20

30

40

Q [l/s]

v [m/s]

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

94

60 Hz

-240/2

24

P2
[kW]

TP, TPE 80

80

TM02 8769 1604

Performance curves/technical data

TP, TPD, TPE 80-XX/2

22
DN 80

B4

B4

B4
AC

P
AC

P
AD
AD

H3

B3

H3
L1

B2

D1
B2

B1

H4

D1
B1

H4

H1

H1

H2

H2

Rp 1/4

L1
M

AE

AE

AF

AF

AE

C1

AF

C1

C5

C6

C5

TM03 5348 3406 - TM03 5348 3406

B4
AD
AD

Performance curves/technical data

2-pole, PN 6, 10, 16

Technical data
TP 80

-160/2

-200/2

-240/2

-290/2

-330/2

-400/2

-480/2

-530/2

-640/2

-750/2

TPD

TPE

TPED

Series

200

300

300

300

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

100

112

132

132

160

160

160

180

200

200

1~ TPE

3~ TPE

112

132

132

160

160

160

180

-/37

1~/3~ TP

[kW]

-/3

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

-/30

1~/3~ TPE [kW]

-/-

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

-/-

-/-

PN 6/PN 10

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN
Tmin;Tmax

[C]

[-25;140]

D1

[mm]

80

80

80

80

80

80

80

80

80

80

[mm]

-/175

-/220

-/220

-/260

-/314

-/314

-/314

-/314

-/407

-/407

AC
AD

1~/3~ TP

1~/3~ TPE [mm]


1~/3~ TP

[mm]

[-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]

-/-

-/220

-/220

-/260

-/314

-/314

-/314

-/314

-/-

-/-

-/110

-/134

-/134

-/159

-/204

-/204

-/204

-/204

-/315

-/315

1~/3~ TPE [mm]

-/-

-/188

-/188

-/213

-/308

-/308

-/308

-/308

-/-

-/-

AE

1~/3~ TPE [mm]

145

145

145

210

210

210

210

AF

1~/3~ TPE [mm]

145

145

145

210

210

210

210

[mm]

250

300

300

350

350

350

350

400

400

B1

[mm]

125/-

125/260 125/260 125/260 176/366 176/366 187/416 187/416 187/416 187/416

B2

[mm]

100/-

119/290 119/290 119/290 144/354 144/354 162/405 162/405 162/405 162/405

B3

[mm]

[mm]

110/-

B4

TP
TPE

340

340

340

400

400

470

470

470

470

134/295 150/320 159/320 204/375 204/375 204/416 204/416 300/436 300/436

[mm]

-/-

[mm]

160/-

C5

[mm]

180

180/78

180/78

180/78

220/93

220/93

C6

[mm]

175

175

175

175

175

175

175

175

L1

[mm]

360

360

360

360

440

440

500

500

500

500

H1

[mm]

97

105

105

105

115

115

115

115

115

115

C1

H2
H3

1~/3~ TP

188/-

188/-

213/-

308/-

308/-

308/-

308/-

-/-

-/-

144/420 144/420 144/420 144/480 144/480 144/550 144/550 144/550 144/550


250/133 250/133 250/133 250/133
175

[mm]

174

204

243

243

273

273

273

273

273

273

[mm]

-/606

-/681

-/739

-/727

-/859

-/859

-/903

-/903

-/999

-/999

-/-

-/681

-/739

-/727

-/859

-/859

-/903

-/929

-/-

-/-

H4

1~/3~ TPE [mm]


[mm]

35

35

35

35

35

35

[mm]

M16

M16

M16

M16

M16

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

95

22
DN 100
2-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 100-XX/2


H
[m]

H
[m]
40

TP, TPE 100

75

60 Hz

70

-370/2

36
32

60 Hz

-630/2

65
-300/2

TP, TPE 100

-700/2

60
-530/2

55

28

50

-230/2

24

45

20

40

-380/2

-350/2

35

16

30

12

25

20

P2
[kW]

20

40

60

80

100 120 140 Q [m/h]

16

P2
[kW]
45

-370/2

40

80

120

160

200

Q [m/h]
-700/2

40

14

-630/2

35

12

-530/2

30

-300/2

10

25

8
6

15

10

20

40

60

80

-380/2
-350/2

20

-230/2

0
NPSH
[m]
24

100 120 140 Q [m/h]

NPSH
[m]
10

40

80

120

160

200

Q [m/h]

-530/2, -630/2, -700/2

20

16

-230/2

20

40

60

80

-350, -380/2

12

-300/2, -370/2

100 120 140 Q [m/h]

Eta
[%]
80

Eta
[%]
80

75

75

80

120

160

200

Q [m/h]

-700/2

70

70
-300/2

65

-370/2

-380/2

65
-350/2

60

60

50

50

45

45

20

40

10

60

80
20

100 120 140 Q [m/h]


30
3

40
4

Q [l/s]
v [m/s]

TM02 8770 1604

-630/2
-530/2

55

-230/2

55

40

10

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

96

40

80

120

20
2

30
3

160
40

200
50

Q [m/h]

60

Q [l/s]

v [m/s]

TM02 8771 4810

22
DN 100

B4

B4

B4
AC

P
AC

P
AD
AD

H3

B3

H3
L1

B2

B1

H4

D1
B1

D1
B2

H4

H1

H1

H2

H2

Rp 1/4

L1
M

AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM03 5348 3406 - TM03 5349 3406

B4
AD
AD

Performance curves/technical data

2-pole, PN 6, 10, 16

Technical data
TP 100
TPD
TPE
TPED
Series

-230/2
-300/2
-370/2

300
300
300
1~ TP
3~ TP
132
160
160
IEC size
1~ TPE
3~ TPE
132
160
160
1~/3~ TP [kW]
-/7.5
-/11
-/15
P2
1~/3~ TPE [kW]
-/7.5
-/11
-/15
PN
PN 16
PN 16
PN 16
[C] [-25;120] [-25;120] [-25;120]
Tmin;Tmax
D1
[mm]
100
100
100
1~/3~ TP [mm] -/260
-/314
-/314
AC
1~/3~ TPE [mm] -/260
-/314
-/314
1~/3~ TP [mm] -/159
-/204
-/204
AD
1~/3~ TPE [mm] -/213
-/308
-/308
AE
1~/3~ TPE [mm]
145
210
210
AF
1~/3~ TPE [mm]
145
210
210
P
[mm]
300
350
350
B1
[mm] 156/347 156/347 156/347
B2
[mm] 124/332 124/332 124/332
B3
[mm]
400
400
400
TP
[mm] 159/350 204/375 204/375
B4
TPE
[mm] 213/308/308/C1
[mm] 144/480 144/480 144/480
C5
[mm] 250/104 250/104 250/104
C6
[mm]
175
175
175
L1
[mm]
500
500
500
H1
[mm]
140
140
140
H2
[mm]
245
275
275
1~/3~ TP [mm] -/764
-/886
-/886
H3
1~/3~ TPE [mm] -/764
-/886
-/886
H4
[mm]
35
35
M
[mm]
M16
M16
M16

-350/2
-380/2
-530/2
-630/2
-700/2

300
300
300
300
300
160
180
200
200
225
160
180
-/18.5
-/22
-/30
-/37
-/45
-/18.5
-/22
-/-/-/PN 16
PN 16
PN 16
PN 16
PN 16
[-25;120] [-25;120] [-25;120] [-25;120] [-25;120]
100
-/314
-/314
-/204
-/308
210
210
350
190/414
151/395
470
204/414
308/230/550
275/110
230
550
140
270
-/925
-/925
35
M16

100
-/314
-/314
-/204
-/308
210
210
350
190/414
151/395
470
204/414
308/230/550
275/110
230
550
140
270
-/925
-/951
35
M16

100
-/407
-/-/310
-/400
201/443
173/429
500
300/451
-/230/550
275/110
230
550
140
307
-/1058
-/35
M16

100
-/407
-/-/310
-/400
201/443
173/429
500
300/451
-/230/550
275/110
230
550
140
307
-/1058
-/35
M16

100
-/439
-/-/338
-/450
201/443
173/429
500
325/475
-/230/550
275/110
230
550
140
337
-/1185
-/35
M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

97

22
DN 32
4-pole, PN 6, 10, 16

Performance curves/technical data

22. Performance curves/technical data


TP, TPD, TPE, 4-pole, PN 6, 10, 16
TP, TPD, TPE 32-XXX/4
H
[m]

H
[m]

TP, TPE 32

9
8

TP, TPE 32

-190/4

20

60 Hz

-80/4

60 Hz

18

7
16

-140/4

14

5
4

-40/4

-120/4

12

10

2
8

0
P2
[kW]
0.16

10

Q [m/h]

P2
[kW]

10

12

Q [m/h]

1.2
-80/4

0.14

-190/4

1.0

0.12
0.8

0.10

-40/4

0.08

-140/4

0.6

0.06

-120/4

0.4

0.04

0.2

0.02

0.0

0.00
0

10

0
NPSH
[m]

Q [m/h]

NPSH
[m]
3.5

10

12

Q [m/h]

10

12

Q [m/h]

2.5
-40/4

3.0

-80/4

2.0

2.5
2.0

1.5

1.5

1.0

1.0

0.5

0.5
0.0

0.0
2

10

Q [m/h]

Eta
[%]
50

-190/4

45

-140/4
-120/4

40
35
-40/4

-80/4

30
25
20

10

Q [m/h]

Q [l/s]

v [m/s]

10

12

Q [m/h]

Q [l/s]

v [m/s]

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

98

TM02 5047 4810

TM02 5046 0504

Eta
[%]
65
60
55
50
45
40
35
30
25
20

22
DN 32

Performance curves/technical data

4-pole, PN 6, 10, 16

B4

B4
AC

P
B3

D1
B2

L1
M

AF

AE

AF

C1

AE

M
C6

C5

TM02 8632 5004 - TM02 8631 5004

B1

H4

H1

H2

H3

AD

Technical data
TP 32

-40/4

-80/4

-120/4

-140/4

-190/4

TPD

TPE

TPED

Series

200

200

300

300

300

IEC size

P2

1~ TP

3~ TP

71

71

80

80

90

1~ TPE

3~ TPE

90

-/0.12

-/0.25

-/0.55

-/0.75

-/1.1

-/-

-/-

-/-

-/-

-/1.1

PN6/10

PN6/10

PN 16

PN 16

PN 16

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN
Tmin;Tmax

[C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120]

D1

[mm]

32

32

32

32

32

[mm]

-/128

-/125

-/141

-/178

-/178

AC
AD

1~/3~ TP

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/-

-/-

-/-

-/-

-/122

-/387

-/395

-/109

-/110

-/110

1~/3~ TPE [mm]

-/-

-/-

-/-

-/-

-/158

AE

1~/3~ TPE [mm]

132

AF

1~/3~ TPE [mm]

132

[mm]

200

200

200

B1

[mm]

75/-

102/-

144/321 144/321 144/321

B2

[mm]

75/-

102/-

144/321 144/321 144/321

B3

[mm]

[mm]

387/-

395/-

B4

TP
TPE

355

355

355

144/321 144/321 144/321

[mm]

-/-

-/-

[mm]

80/-

80/-

144/435 144/435 144/435

C5

[mm]

110

140

220/46

220/46

C6

[mm]

175

175

175

L1

[mm]

220

280

440

440

440

H1

[mm]

68

79

100

100

100

H2

[mm]

142

137

156

156

156

[mm]

-/401

-/407

-/487

-/537

-/490

-/-

-/-

-/-

-/-

-/537

C1

H3

1~/3~ TP

1~/3~ TPE [mm]

-/-

-/-

167/220/46

H4

[mm]

[mm]

M12

M12

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

99

22
DN 40
4-pole, PN 6, 10, 16

H
[m]

H
[m]
8

TP, TPE 40

24

60 Hz

22

-80/4

20

-190/4

16

-160/4

14

-120/4

-40/4

12

10

8
6

0
0

10

12

14

16

18Q [m/h]

P2
[kW]

12

16

20

Q [m/h]

-220/4
-190/4

1.2

0.3

-160/4

0.8

0.2

-120/4

0.4

-40/4

0.1

0.0

0.0
0

10

12

14

16

0
NPSH
[m]

18Q [m/h]

12

16

20

Q [m/h]

12

16

20

Q [m/h]

3.0

3.5

2.5

3.0

2.0

2.5

1.5

2.0
-80/4

1.5
1.0

1.0
0.5

-40/4

0.5

0.0

0.0
0

10

12

14

16

Q [m/h]

Eta
[%]

50
-220/4

45

-190/4

-160/4

40

-80/4

-120/4

35
30

-40/4

25
20

0
0

10

2
1

12
3

14

16

4
3

Q [m/h]
5

Q [l/s]
v [m/s]

TM02 5048 0504

0
0

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

100

1.6

-80/4

0.4

Eta
[%]
65
60
55
50
45
40
35
30
25
20

2.0

0.5

NPSH
[m]
4.0

60 Hz

18

P2
[kW]

TP, TPE 40

-220/4

12

2
1

16

20

4
2

Q [m/h]
6

Q [l/s]
v [m/s]

TM02 5049 4810

Performance curves/technical data

TP, TPD, TPE 40-XXX/4

22
DN 40

Performance curves/technical data

4-pole, PN 6, 10, 16

B4

B4
AC

P
B3

D1
B2

L1
M

AF

AE

AF

C1

AE

M
C6

C5

TM02 8632 5004 - TM02 8631 5004

B1

H4

H1

H2

H3

AD

Technical data
TP 40

-40/4

-80/4

-120/4

-160/4

-190/4

-220/4

TPD

TPE

TPED

Series

200

200

300

300

300

300

IEC size

P2

1~ TP

3~ TP

71

80

80

90

90

100

1~ TPE

3~ TPE

80

90

90

100

-/0.25

-/0.55

-/0.75

-/1.1

-/1.5

-/2.2

-/-

-/-

-/0.75

-/1.1

-/1.5

-/2.2

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN
Tmin;Tmax

[C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120]

D1
AC
AD

1~/3~ TP

[mm]

40

40

40

40

40

40

[mm]

-/142

-/142

-/178

-/178

-/178

-/198

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/-

-/-

-/141

-/122

-/178

-/198

-/109

-/109

-/110

-/110

-/110

-/120

1~/3~ TPE [mm]

-/-

-/-

-/140

-/158

-/167

-/177

AE

1~/3~ TPE [mm]

105

132

132

132

AF

1~/3~ TPE [mm]

105

132

132

132

[mm]

200

200

200

250

B1

[mm]

85/-

100/-

149/325 149/325 149/325 149/325

B2

[mm]

75/-

100/-

144/321 144/321 144/321 144/321

B3

[mm]

[mm]

109/-

109/-

B4

TP
TPE

355

355

355

355

149/325 149/325 149/325 149/325

[mm]

-/-

-/-

[mm]

120/-

120/-

144/435 144/435 144/435 144/435

C5

[mm]

125

125

220/108 220/108 220/108 220/108

C6

[mm]

175

175

175

175

L1

[mm]

250

250

440

440

440

440

H1

[mm]

67

75

110

110

110

110

H2

[mm]

132

135

158

158

158

186

[mm]

-/390

-/441

-/549

-/549

-/589

-/631
-/631

C1

H3

1~/3~ TP

1~/3~ TPE [mm]

149/-

167/-

167/-

177/-

-/-

-/-

-/499

-/502

-/589

H4

[mm]

[mm]

M12

M12

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

101

22
DN 50
4-pole, PN 6, 10, 16

H
[m]

H
[m]

TP, TPE 50

16

TP, TPE 50

36

60 Hz

-140/4

32

-120/4

12

-270/4

28
10
-110/4

24

-80/4

20

-40/4

16

-240/4

8
6
4

0
P2
[kW]
1.4

8
0

12

16

20

24

28 Q [m/h]
P2
[kW]

-140/4

10 15 20 25 30 35 40 45Q [m/h]

6
-340/4

1.2

-120/4

1.0

0.8

-110/4

-270/4

0.6

-240/4

-80/4

-190/4

0.4
0.2

-40/4

0.0

0
NPSH
[m]
4.0

12

16

20

24

28 Q [m/h]

0
NPSH
[m]
7

-80/4

3.5

10 15 20 25 30 35 40

Q [m/h]

10 15 20 25 30 35 40

Q [m/h]

3.0

2.5

2.0
-40/4

1.5

3
2

1.0

-110/4, -120/4, -140/4

0.5

0.0
Eta
[%]
70

-190/4

12

0
0

12

16

20

24

28 Q [m/h]
Eta
[%]
65

-40/4

65

60

60

-240/4 -270/4 -340/4

55

55

45

-140/4

45

-120/4

40

40

-110/4

35

-190/4

50

-80/4

50

35

30

30

0
0

8
2
1

12

16
4

20

24
6

28 Q [m/h]
8

Q [l/s]
v [m/s]

0
TM02 5050 4810

0
0

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

102

60 Hz

-340/4

14

10 15 20 25 30 35 40
2
1

6
2

8
3

10
4

Q [m/h]
12

Q [l/s]
v [m/s]

TM02 5051 4810

Performance curves/technical data

TP, TPD, TPE 50-XXX/4

22
DN 50

Performance curves/technical data

4-pole, PN 6, 10, 16

B4

B4
AC

P
B3

D1
B2

L1
M

AF

AE

AF

C1

AE

M
C6

C5

TM02 8632 5004 - TM02 8631 5004

B1

H4

H1

H2

H3

AD

Technical data
TP 50

-40/4

-80/4

-110/4

-120/4

-140/4

-190/4

-240/4

-270/4

-340/4

TPD

TPE

TPED

Series

200

200

300

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

71

80

80

90

90

100

100

112

132

1~ TPE

3~ TPE

80

90

90

100

100

112

132

-/0.25

-/0.55

-/0.75

-/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

-/-

-/-

-/0.75

-/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN
Tmin;Tmax

[C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]

D1
AC
AD

1~/3~ TP

[mm]

50

50

50

50

50

50

50

50

50

[mm]

-/142

-/142

-/178

-/178

-/178

-/198

-/198

-/220

-/260

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/-

-/-

-/141

-/122

-/178

-/198

-/198

-/220

-/260

-/109

-/109

-/110

-/110

-/110

-/120

-/120

-/134

-/159

1~/3~ TPE [mm]

-/-

-/-

-/140

-/158

-/167

-/177

-/177

-/188

-/213

AE

1~/3~ TPE [mm]

105

132

132

132

132

145

145

AF

1~/3~ TPE [mm]

105

132

132

132

132

145

145

[mm]

200

200

200

250

250

250

300

B1

[mm]

90/-

110/-

180/386 180/386 180/386 180/386 180/386 180/386 180/386

B2

[mm]

75/-

100/-

164/379 164/379 164/379 164/379 164/379 164/379 164/379

B3

[mm]

[mm]

109/-

109/-

B4

TP
TPE

420

420

420

420

420

420

420

180/386 180/386 180/386 180/386 180/386 180/386 180/386

[mm]

-/-

-/-

C1

[mm]

120/-

120/-

144/500 144/500 144/500 144/500 144/500 144/500 144/500

C5

[mm]

140

140

220/123 220/123 220/123 220/123 220/123 220/123 220/123

C6

[mm]

175

175

175

175

175

175

L1

[mm]

280

280

440

440

440

440

440

440

440

H1

[mm]

82

82

115

115

115

115

115

115

115

H2
H3

1~/3~ TP

-/-

180/-

180/-

180/-

180/-

188/-

213/-

175

[mm]

136

140

167

167

167

195

195

195

234

[mm]

-/409

-/453

-/563

-/563

-/563

-/645

-/645

-/682

-/728
-/728

-/-

-/-

-/513

-/516

-/603

-/645

-/645

-/682

H4

1~/3~ TPE [mm]


[mm]

[mm]

M12

M12

M16

M16

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

103

22
DN 65
4-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 65-XXX/4


H
[m]

H
[m]

TP, TPE 65

-150/4

16

60 Hz

14

TP, TPE 65

36

-330/4

32

-310/4

60 Hz

-130/4

12

28

10
8

-190/4

20

6
-40/4

16
12

2
0
P2
[kW]

-230/4

24

-80/4

8
0

10 15 20 25 30 35 40 45Q [m/h]

P2
[kW]
7

2.4

10

20

30

40

50

60

Q [m/h]
-330/4

-150/4

2.0

-310/4

1.6
-130/4

1.2

-80/4

0.8

-230/4
-190/4

0.4

-40/4

0.0

0
NPSH
[m]
3.5

10 15 20 25 30 35 40 45Q [m/h]

0
NPSH
[m]

10

20

30

40

50

60

Q [m/h]

10

20

30

40

50

60

Q [m/h]

-40/4

3.0

-80/4

2.5

2.0
2

1.5
1.0

-130/4, -150/4

0.5
0.0
5

10 15 20 25 30 35 40 45Q [m/h]

Eta
[%]
70

70

-310/4

65
-80/4

65
60
55

50

50

45
-40/4

45

40

40

35
5

10 15 20 25 30 35 40 45Q [m/h]

0.0

0.5

1.0

1.5

8
2.0

10
2.5

12
3.0

Q [l/s]
v [m/s]

0
TM02 5052 4810

10

20

0
0

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

104

-330/4

55

-150/4

-130/4

-230/4
-190/4

60

30

5
1

40
10

50

60
15

Q [m/h]
Q [l/s]
5 v [m/s]

TM02 5053 4810

Eta
[%]
75

0
0

22
DN 65

Performance curves/technical data

4-pole, PN 6, 10, 16

B4

B4
AC

P
B3

D1
B2

L1
M

AF

AE

AF

C1

AE

M
C6

C5

TM02 8632 5004 - TM02 8631 5004

B1

H4

H1

H2

H3

AD

Technical data
TP 65

-40/4

-80/4

-130/4

-150/4

-190/4

-230/4

-310/4

-330/4

TPD

TPE

TPED

Series

200

200

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

71

90

90

100

100

112

132

132

1~ TPE

3~ TPE

90

100

100

112

132

160

-/0.37

-/1.1

-/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

-/-

-/-

-/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

PN 6/10

PN 6/10

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN
Tmin;Tmax

[C] [-25;140] [-25;140] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]

D1
AC
AD

1~/3~ TP

[mm]

65

65

65

65

65

65

65

65

[mm]

-/142

-/175

-/178

-/198

-/198

-/220

-/260

-/260

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/-

-/-

-/178

-/198

-/198

-/220

-/260

-/260

-/125

-/125

-/110

-/120

-/120

-/134

-/159

-/159

1~/3~ TPE [mm]

-/-

-/-

-/167

-/177

-/177

-/188

-/213

-/213

AE

1~/3~ TPE [mm]

132

132

132

145

145

145

AF

1~/3~ TPE [mm]

132

132

132

145

145

145

[mm]

200

250

250

250

300

300

B1

[mm]

125/-

125/-

178/349 178/349 178/349 178/349 178/349 178/349

B2

[mm]

100/-

100/-

164/383 164/383 164/383 164/383 164/383 164/383

B3

[mm]

[mm]

125/-

125/-

B4

TP
TPE

440

440

440

440

440

440

178/383 178/383 178/383 178/383 178/383 178/383

[mm]

-/-

-/-

[mm]

160/-

160/-

144/520 144/520 144/520 144/520 144/520 144/520

C5

[mm]

170

170

238/111 238/111 238/111 238/111 238/111 238/111

C6

[mm]

175

175

175

175

175

L1

[mm]

340

340

475

475

475

475

475

475

H1

[mm]

97

97

125

125

125

125

125

125

C1

H2
H3

1~/3~ TP

178/-

178/-

178/-

188/-

213/-

213/-

175

[mm]

136

158

166

194

194

194

233

233

[mm]

-/424

-/536

-/612

-/654

-/654

-/691

-/737

-/787
-/817

-/-

-/-

-/612

-/654

-/654

-/691

-/749

H4

1~/3~ TPE [mm]


[mm]

35

[mm]

M16

M16

M16

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

105

22
DN 80
4-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 80-XXX/4


H
[m]
20

TP, TPE 80

H
[m]

60 Hz

55

-170/4

18
16

TP, TPE 80
-510/4

50

-150/4

60 Hz

-460/4

45

14

-410/4

12

40

-110/4

10

35

-340/4

30

-280/4

25

-230/4

-80/4

-40/4

20

15

0
0

10

20

30

40

50

60

10

70 Q [m/h]

P2
[kW]

-170/4

40

60

80

100 120 140 Q [m/h]

-510/4

3.0

-150/4

20

-110/4

16

2.5
2.0
1.5

-460/4
-410/4

12

-80/4

-340/4

1.0
0.5

-280/4
-230/4

-40/4

0.0

0
NPSH
[m]
7

10

20

30

40

50

60

70 Q [m/h]
NPSH
[m]
7

-40/4

20

40

60

80

100 120 140 Q [m/h]


-280/4, -340/4, -410/4
-460/4, -510/4

4
3

-80/4

-110/4

-230/4

2
-150/4, -170/4

10

20

30

40

50

60

70 Q [m/h]
Eta
[%]

-110/4
-170/4

20

40

60

100 120 140 Q [m/h]

-280/4

65

-80/4

-230/4

60
-40/4

55

80

70

65
60

75

-150/4

70

-510/4
-340/4
-460/4
-410/4

55

50

50

45

45

40

40

10

20

30

40

50

60

10

15

70 Q [m/h]
20

Q [l/s]

4 v [m/s]

0
TM02 5054 4810

20

40

60

80

100 120 140 Q [m/h]

10

20

30

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

106

20

24

3.5

Eta
[%]
75

40

Q [l/s]

8 v [m/s]

TM02 8772 1604

P2
[kW]
4.0

22
DN 80

B4

B4

B4
AC

P
AC

P
AD
AD

H3

B3

H3
L1

B2

B1

H4

D1
B1

D1
B2

H4

H1

H1

H2

H2

Rp 1/4

TM03 5348 3406 - TM03 5349 3406

B4
AD
AD

Performance curves/technical data

4-pole, PN 6, 10, 16

L1
M

AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

Technical data
TP 80

-40/4

-80/4

-110/4

-150/4

-170/4

-230/4

-280/4

-340/4

-410/4

-460/4

-510/4

TPD

TPE

TPED

Series

200

200

300

300

300

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

80

90

100

100

112

132

132

160

160

180

180

1~ TPE

3~ TPE

100

112

112

132

160

160

160

180

-/0.75

-/1.5

-/2.2

-/3

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/22

-/-

-/-

-/2.2

-/3

-/4

-/5.5

-/7.5

-/11

-/15

-/18.5

-/-

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN

PN 6/PN 10 PN 6/PN 10

Tmin;Tmax

[C]

[-25;140]

[-25;140]

D1

[mm]

80

80

80

80

80

80

80

80

80

80

80

[mm]

-/178

-/175

-/198

-/198

-/220

-/267

-/260

-/314

-/314

-/368

-/368

AC
AD

1~/3~ TP

1~/3~ TPE [mm]


1~/3~ TP

[mm]

[-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]

-/-

-/-

-/198

-/198

-/220

-/260

-/260

-/314

-/314

-/314

-/-

-/110

-/135

-/120

-/120

-/134

-/167

-/159

-/204

-/204

-/286

-/286

1~/3~ TPE [mm]

-/-

-/-

-/177

-/177

-/188

-/213

-/213

-/308

-/308

-/308

-/-

AE

1~/3~ TPE [mm]

132

132

145

145

145

210

210

210

-/-

AF

1~/3~ TPE [mm]

132

132

145

145

145

210

210

210

-/-

[mm]

115

250

250

250

300

300

350

350

350

350

B1

[mm]

130/-

135/-

176/366 187/416 187/416 243/491 243/491 243/491 243/491 243/491 243/491

B2

[mm]

100/-

100/-

144/354 162/405 162/405 226/480 226/480 226/480 226/480 226/480 226/480

B3

[mm]

[mm]

130/-

135/-

B4

TP
TPE

400

470

470

470

470

470

470

470

470

176/366 187/416 187/416 243/491 243/491 243/491 243/491 262/491 262/491

[mm]

-/-

-/-

[mm]

160/-

160/-

C5

[mm]

180

180

220/93

C6

[mm]

175

175

175

350

350

350

350

350

350

L1

[mm]

360

360

440

500

500

620

620

620

620

620

620

H1

[mm]

107

107

115

115

115

140

140

140

140

140

140

H2

[mm]

175

164

204

204

204

273

273

303

303

303

303

[mm]

-/563

-/592

-/654

-/654

-/691

-/786

-/842

-/914

-/958

-/958

-/1049

C1

H3

1~/3~ TP

1~/3~ TPE [mm]

177/-

187/-

188/-

243/-

243/-

308/-

308/-

308/-

-/-

144/480 144/550 144/550 230/550 230/550 230/550 230/550 230/550 230/550


250/133 250/133 310/105 310/105 310/105 310/105 310/105 310/105

-/-

-/-

-/654

-/654

-/691

-/792

-/872

-/914

-/958

-/984

-/-

H4

[mm]

35

35

35

35

35

[mm]

M16

M16

M16

M16

M16

M16

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

107

22
DN 100
4-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 100-XXX/4


H
[m]

TP, TPE 100

20
18

-170/4

16

-150/4

14

60 Hz

-130/4

12

-100/4

10
-80/4

-40/4

6
4
2
0
P2
[kW]

20

40

60

80

100

120

Q [m/h]

-170/4

-150/4

5
4

-130/4

-100/4

-80/4

-40/4

0
0
NPSH
[m]

20

40

60

80

100

120

-130/4, -170/4

-80/4

Q [m/h]

-40/4

12
10
8

-150/4

6
4
2

-100/4

0
Eta
[%]
80

20

40

60

80

100

120

Q [m/h]

75

-150/4
-100/4

70
65

-130/4

60

-170/4
-80/4

55
50

-40/4

45
40
20

40
10

60
15

80
20

100
25

30

120

Q [m/h]

35

Q [l/s]

0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0

v [m/s]

TM02 5055 3213

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

108

22
DN 100

B4

B4

B4
AC

P
AC

P
AD
AD

H3

B3

H3
L1

B2

B1

H4

D1
B1

D1
B2

H4

H1

H1

H2

H2

Rp 1/4

L1
M

AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM03 5348 3406 - TM03 5349 3406

B4
AD
AD

Performance curves/technical data

4-pole, PN 6, 10, 16

Technical data
TP 100

-40/4

-80/4

-100/4

-130/4

-150/4

-170/4

TPD

TPE

TPED

Series

200

200

300

300

300

300

IEC size

P2

1~ TP

3~ TP

90

100

100

112

132

132

1~ TPE

3~ TPE

112

112

113

132

-/1.1

-/2.2

-/3

-/4

-/5.5

-/5.5

-/-

-/-

-/3

-/4

-/5.5

-/5.5

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN

PN6/PN 10 PN 6/PN 10

Tmin;Tmax

[C]

D1
AC
AD

1~/3~ TP

[-25;140]

[-25;120] [-25;120] [-25;120] [-25;120]

[mm]

100

100

100

100

100

100

[mm]

-/175

-/175

-/198

-/220

-/260

-/260

1~/3~ TPE [mm]


1~/3~ TP

[-25;140]

[mm]

-/-

-/-

-/198

-/220

-/260

-/260

-/174

-/174

-/120

-/134

-/159

-/159

1~/3~ TPE [mm]

-/-

-/-

-/177

-/188

-/213

-/213

AE

1~/3~ TPE [mm]

132

145

145

145

AF

1~/3~ TPE [mm]

132

145

145

145

[mm]

250

250

300

300

B1

[mm]

174/-

174/-

190/414 201/443 190/414 201/443

B2

[mm]

120/-

120/-

151/395 173/429 151/395 173/429

B3

[mm]

[mm]

174/-

174/-

B4

TP
TPE

470

500

470

500

190/414 201/443 190/414 201/443

[mm]

-/-

-/-

[mm]

200/-

200/-

230/550 230/550 230/550 230/550

C5

[mm]

225

225

275/110 275/110 275/110 275/110

C6

[mm]

230

230

230

230

L1

[mm]

450

450

550

550

550

550

H1

[mm]

122

122

140

140

140

140

H2

[mm]

183

193

201

261

240

277

[mm]

-/585

-/650

-/676

-/773

-/759

-/796
-/796

C1

H3

1~/3~ TP

1~/3~ TPE [mm]

190/-

201/-

213/-

213/-

-/-

-/-

-/676

-/773

-/759

H4

[mm]

[mm]

M16

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

109

22
DN 100
4-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 100-XXX/4


H
[m]

TP, TPE 100

50

60 Hz

-470/4

45
-390/4

40

-350/4

35

-340/4
-290/4

30
25

-240/4

20

-200/4

-260/4

15
10
P2
[kW]

0 20 40 60 80 100120140160180200 Q [m/h]
-470/4

30
25

-390/4
-350/4
-340/4
-290/4
-260/4
-240/4
-200/4

20
15
10
5
0

0 20 40 60 80 100120140160180200 Q [m/h]
NPSH
[m]
-260/4
14
-290/4, -340/4
-390/4, -470/4

12
10
8
6
4

-200/4, -240/4, -350/4

2
0
Eta
[%]
80

0 20 40 60 80 100120140160180200 Q [m/h]
-260/4 -290/4

-350/4
-470/4

75
70

-340/4 -390/4
-200/4 -240/4

65
60
55
50
45
40

110

10

20
2

30
3

40
4

50
5

60 Q [l/s]
7 v [m/s]

TM02 8773 3213

0 20 40 60 80 100120140160180200 Q [m/h]

22
DN 100

B4

B4

B4
AC

P
AC

P
AD
AD

H3

B3

H3
L1

B2

B1

H4

D1
B1

D1
B2

H4

H1

H1

H2

H2

Rp 1/4

L1
M

AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM03 5348 3406 - TM03 5349 3406

B4
AD
AD

Performance curves/technical data

4-pole, PN 6, 10, 16

Technical data
TP 100

-200/4

-240/4

-260/4

-290/4

-340/4

-350/4

-390/4

-470/4

TPD

TPE

TPED

Series

300

300

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

132

160

160

160

180

160

180

200

1~ TPE

3~ TPE

160

160

161

160

180

180

[kW]

-/7.5

-/11

-/11

-/15

-/18.5

-/22

-/22

-/30

1~/3~ TPE [kW]

-/7.5

-/11

-/11

-/15

-/18.5

-/-

-/22

-/-

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

PN
Tmin;Tmax

[C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]

D1

[mm]

100

100

100

100

100

100

100

100

[mm]

-/260

-/314

-/314

-/314

-/368

-/363

-/368

-/408

AC
AD

1~/3~ TP

1~/3~ TPE [mm]

-/260

-/314

-/314

-/314

-/314

-/-

-/350

-/-

1~/3~ TP

[mm]

-/159

-/204

-/204

-/204

-/286

-/262

-/286

-/315

1~/3~ TPE [mm]

-/213

-/308

-/308

-/308

-/308

-/-

-/439

-/-

AE

1~/3~ TPE [mm]

145

210

210

210

210

164

AF

1~/3~ TPE [mm]

145

210

210

210

210

164

[mm]

300

350

350

350

350

350

350

400

B1

[mm] 290/579 290/579 201/443 290/579 290/579 290/579 290/579 290/579

B2

[mm] 249/561 249/561 173/429 249/561 249/561 249/561 249/561 249/561

B3

[mm]

B4

TP
TPE

C1

600

600

500

600

600

600

600

600

[mm] 290/579 290/579 204/443 290/579 290/579 290/579 290/579 300/579


[mm]

290/-

308/-

308/-

308/-

308/-

-/-

439/-

-/-

[mm] 230/680 230/680 230/550 230/680 230/680 230/680 230/680 230/680

C5

[mm] 335/110 335/110 275/110 335/110 335/110 335/110 335/110 335/110

C6

[mm]

350

350

230

350

350

350

350

L1

[mm]

670

670

550

670

670

670

670

670

H1

[mm]

175

175

140

175

175

175

175

175

H2
H3

350

[mm]

254

308

307

308

308

308

308

308

[mm]

-/858

-/954

-/826

-/998

-/998

-/1093

-/1079

-/1128

1~/3~ TPE [mm]

1~/3~ TP

-/888

-/954

-/826

-/998

-/998

-/-

-/1008

-/-

H4

[mm]

35

35

35

35

35

35

35

[mm]

M16

M16

M16

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

111

22
DN 125
4-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 125-XXX/4


H
[m]
15

TP, TPE 125

-140/4

14
13

60 Hz

-120/4

12
11

-100/4

10
9
8
7
6
5
4
3
P2
[kW]

20 40 60 80 100 120 140 160

Q [m/h]

5
-140/4

-120/4

-100/4

2
1
0
0
NPSH
[m]

20 40 60 80 100 120 140 160

Q [m/h]

4.0
3.5

-100/4

3.0
-140/4

2.5

-120/4

2.0
1.5
1.0
Eta
[%]
80

20 40 60 80 100 120 140 160

Q [m/h]

75
70
65

-100/4 -120/4

60

-140/4

55
50
45
40

0
0

20 40 60 80 100 120 140 160


10

20
1

30
2

40
3

Q [m/h]
50 Q [l/s]
v [m/s]

TM05 9411 3813

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

112

22
DN 125

TM05 9447 3813

Performance curves/technical data

4-pole, PN 6, 10, 16

Technical data
TP 125

-100/4

-120/4

TPD

-140/4
-

TPE

TPED

Series

300

300

300

IEC size

P2

1~ TP

3~ TP

100

112

132

1~ TPE

3~ TPE

100

112

132

-/3

-/4

-/5.5

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN

-/3

-/4

-/5.5

PN 16

PN 16

PN 16

Tmin;Tmax

[C] [-25;120] [-25;120] [-25;120]

D1

[mm]

125

125

125

[mm]

-/198

-/220

-/267

AC
AD

1~/3~ TP

1~/3~ TPE [mm]

-/198

-/220

-/260

1~/3~ TP

[mm]

-/120

-/134

-/167

1~/3~ TPE [mm]

-/177

-/188

-/213

AE

1~/3~ TPE [mm]

-/132

-/145

-/145

AF

1~/3~ TPE [mm]

-/132

-/145

-/145

[mm]

250

250

300

B1

[mm]

243/-

243/-

243/-

B2
B4

TP

193/-

193/-

193/-

[mm]

232/-

232/-

232/-

[mm]

232/-

232/-

232/-

L1

[mm]

620

620

620

H1

[mm]

210

210

210

H2

[mm]

-/225

-/225

-/225

[mm]

-/771

-/808

-/828

1~/3~ TPE [mm]

-/771

-/808

-/828

H3

TPE

[mm]

1~/3~ TP

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

113

22
DN 125
4-pole, PN 6, 10, 16

H
[m]

H
[m]

TP, TPE 125

16

60 Hz

-160/4

15
14
13

50

-490/4

45

-430/4

-360/4

35

11
10

30

25

-320/4

-230/4

8
20

7
6

15
0

20 40 60 80 100 120 140 160

Q [m/h]

P2
[kW]

80

120

160

200

240

Q [m/h]

-490/4

35
30

-430/4

25

-130/4

-360/4
-320/4

20

15

-230/4

10

0
NPSH
[m]

20 40 60 80 100 120 140 160

Q [m/h]

0
NPSH
[m]

40

80

120

160

200

240

Q [m/h]

-320/4, -360/4, -430/4, -490/4

-230/4

-130/4, -160/4

1
0

20 40 60 80 100 120 140 160

Q [m/h]

Eta
[%]
80

75
70

40

80

120

160

200

240

Q [m/h]

-230/4

75

-160/4

65

70

-130/4

65

60

50

45

45

40

-490/4

-360/4

55

50

-430/4

-320/4

60

55

40

0
0

20 40 60 80 100 120 140 160


10

20
1

30
2

40
3

Q [m/h]
50 Q [l/s]
v [m/s]

TM02 8774 1604

40

10

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

114

40

40

-160/4

Eta
[%]

60 Hz

40

-130/4

12

P2
[kW]

TP, TPE 125

80

120

20
1

30
2

160
40
3

200
50
4

240

60

70
5

Q [m/h]
Q [l/s]
v [m/s]

TM02 8775 3213

Performance curves/technical data

TP, TPD, TPE 125-XXX/4

22
DN 125

B4

B4

B4
AC

P
AC

P
AD
AD

H3

B3

H3
L1

B2

B1

H4

D1
B1

D1
B2

H4

H1

H1

H2

H2

Rp 1/4

L1
M

AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM03 5348 3406 - TM03 5349 3406

B4
AD
AD

Performance curves/technical data

4-pole, PN 6, 10, 16

Technical data
TP 125

-130/4

-160/4

-230/4

-320/4

-360/4

-430/4

-490/4

TPD

TPE

TPED

Series

300

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

132

132

160

180

180

200

225

1~ TPE

3~ TPE

132

160

160

180

180

[kW]

-/5.5

-/7.5

-/15

-/18.5

-/22

-/30

-/37

1~/3~ TPE [kW]

-/5.5

-/7.5

-/15

-/18.5

-/22

-/-

-/-

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

1~/3~ TP

PN
Tmin;Tmax

[C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]

D1

[mm]

125

125

125

125

125

125

125

[mm]

-/267

-/267

-/314

-/368

-/368

-/408

-/449

AC
AD

1~/3~ TP

1~/3~ TPE [mm]

-/260

-/260

-/314

-/314

-/350

-/-

-/-

1~/3~ TP

[mm]

-/167

-/167

-/204

-/286

-/286

-/315

-/338

1~/3~ TPE [mm]

-/213

-/213

-/308

-/308

-/439

-/-

-/-

AE

1~/3~ TPE [mm]

-/145

-/145

-/210

-/210

-/164

AF

1~/3~ TPE [mm]

-/145

-/145

-/210

-/210

-/164

300

300

350

350

350

400

450

[mm]

B1

[mm] 250/537 250/537 250/537 271/566 271/566 271/566 271/566

B2

[mm] 220/518 220/518 220/518 243/552 243/552 243/552 243/552

B3

[mm]

B4

TP
TPE

C1

600

600

600

600

600

600

600

[mm] 250/537 250/537 250/537 271/566 271/566 300/566 325/566


[mm]

250/-

250/-

308/-

308/-

439/-

-/-

-/-

[mm] 230/680 230/680 230/680 230/680 230/680 230/680 230/680

C5

[mm]

310/84

310/84

310/84

C6

[mm]

300

300

300

350

350

350

L1

[mm]

620

620

620

800

800

800

800

H1

[mm]

215

215

215

215

215

215

215

H2
H3

400/175 400/175 400/175 400/175


350

[mm]

283

283

312.5

318

318

318

348

[mm]

-/870

-/908

-/1042.5

-/1048

-/1139

-/1178

-/1211

1~/3~ TPE [mm]

1~/3~ TP

-/877

-/969

-/1042.5

-/1074

-/1058

-/-

-/-

H4

[mm]

35

35

35

35

35

35

[mm]

M16

M16

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

115

22
DN 150
4-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPD, TPE 150-XXX/4


H
[m]
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
P2
[kW]

TP, TPE 150


60 Hz

-340/4

-300/4

-240/4
-210/4
-180/4

40 80 120 160 200 240 280 320 360

Q [m/h]
-340/4

35
-300/4

30
25

-240/4

20

-210/4

15

-180/4

10
5
0
NPSH
[m]

40 80 120 160 200 240 280 320 360

Q [m/h]

40 80 120 160 200 240 280 320 360

Q [m/h]

8
7
6
5
4
3
2
0

-340/4
-300/4
-240/4
-210/4
-180/4

40 80 120 160 200 240 280 320 360

20

40

60

80
4

100
5

Q [m/h]
Q [l/s]
6v [m/s]

TM02 8776 2312

Eta
[%]
85
80
75
70
65
60
55
50
45
40

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

116

22
DN 150

B4

B4

B4
AC

P
AC

P
AD
AD

H3

B3

H3
L1

B2

B1

H4

D1
B1

D1
B2

H4

H1

H1

H2

H2

Rp 1/4

L1
M

AE

AF

AE

AF

AE

C1

AF

C1

C5

C6

C5

TM03 5348 3406 - TM03 5349 3406

B4
AD
AD

Performance curves/technical data

4-pole, PN 6, 10, 16

Technical data
TP 150

-180/4

-210/4

-240/4

-300/4

-340/4

TPD

TPE

TPED

Series

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

160

180

180

200

225

1~ TPE

3~ TPE

160

180

180

-/37

1~/3~ TP

[kW]

-/15

-/18.5

-/22

-/30

1~/3~ TPE [kW]

-/15

-/18.5

-/22

-/-

-/-

PN 16

PN 16

PN 16

PN 16

PN 16

PN
Tmin;Tmax

[C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]

D1

[mm]

150

150

150

150

150

[mm]

-/314

-/368

-/368

-/408

-/442

AC
AD

1~/3~ TP

1~/3~ TPE [mm]

-/314

-/314

-/350

-/-

-/-

1~/3~ TP

[mm]

-/204

-/286

-/286

-/315

-/325

1~/3~ TPE [mm]

-/308

-/308

-/439

-/-

-/-

AE

1~/3~ TPE [mm]

210

210

164

-/-

-/-

AF

1~/3~ TPE [mm]

210

210

164

-/-

-/-

[mm]

350

350

350

400

450

B1

[mm] 296/583 296/583 296/583 296/583 296/583

B2

[mm] 237/553 237/553 237/553 237/553 237/553

B3

[mm]

B4

TP
TPE

C1

600

600

600

600

600

[mm] 296/583 296/583 296/583 300/583 325/583


[mm]

308/-

308/-

439/-

-/-

-/-

[mm] 230/680 230/680 230/680 230/680 230/680

C5

[mm] 400/153 400/153 400/153 400/153 400/153

C6

[mm]

350

350

350

350

L1

[mm]

800

800

800

800

800

H1

[mm]

215

215

215

215

215

H2
H3

350

[mm]

321

321

321

321

351.5

[mm]

-/1052

-/1052

-/1133

-/1182

-/1215.5

1~/3~ TPE [mm]

1~/3~ TP

-/1052

-/1078

-/1062

-/-

-/-

H4

[mm]

35

35

36

35

35

[mm]

M16

M16

M16

M16

M16

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

117

22
DN 150
4-pole, PN 6, 10, 16

H
[m]

H
[m]
26
24

-250/4

22
20

-230/4
-190/4

18

-170/4

TP, TPE 150

TP, TPE 150

90

60 Hz

60 Hz

80
-700/4

70
60

16
14
12

50

-610/4
-480/4

40

-440/4

10
8

30

20

10

0
P2
[kW]
20

50

100 150 200 250 300 350 Q [m/h]

P2
[kW]

100

-700/4

80

16

-610/4

-190/4

14

60

12
-170/4

10

-480/4
-440/4

40

20

4
0
NPSH
[m]
14

50

0
NPSH
[m]

100 150 200 250 300 350 Q [m/h]

50 100 150 200 250 300 350 400

10

-170/4

12

-700/4

-480/4

-190/4
-230/4
-250/4

8
6

Q [m/h]

-610/4

10

6
4

-440/4

4
2

0
0

50

100 150 200 250 300 350 Q [m/h]

Eta
[%]
85
80
75
70
65
60
55
50
45
40

-250/4
-230/4
-170/4 -190/4

50

20

40

60
3

80
4

100
5

Q [l/s]
v [m/s]

50 100 150 200 250 300 350 400

Q [m/h]

-700/4
-440/4

100 150 200 250 300 350 Q [m/h]


TM05 0047 0611

-610/4
-480/4

50 100 150 200 250 300 350 400

20

40

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

118

Q [m/h]

-250/4
-230/4

18

Eta
[%]
85
80
75
70
65
60
55
50
45
40

50 100 150 200 250 300 350 400

60
3

80
4

100
5

120
6

Q [m/h]
Q [l/s]
7v [m/s]

TM05 0539 1211

Performance curves/technical data

TP, TPD, TPE 150-XXX/4

22
DN 150

TP
TP
TP
TP

150-170/4
150-190/4
150-230/4
150-250/4

150-440/4
150-480/4
150-610/4
150-700/4

TM05 0661 1411 - TM05 0662 1411

TP
TP
TP
TP

Performance curves/technical data

4-pole, PN 6, 10, 16

Technical data
TP 150

-170/4

-190/4

-230/4

-250/4

-440/4

-480/4

-610/4

-700/4

TPD

TPE

TPED

Series

300

300

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

160

160

180

180

225

250

280

280
-

1~ TPE

3~ TPE

160

160

180

-/11

-/15

-/18.5

-/22

-/45

-/55

-/75

-/90

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN
Tmin;Tmax

AD

-/15

-/18.5

-/-

-/ -

-/ -

-/ -

-/ -

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

[C] [-25.120] [-25.120] [-25.120] [-25.120] [-25.120] [-25.120] [-25.120] [-25.120]

D1
AC

-/11
PN 16

1~/3~ TP

[mm]

150

150

150

150

150

150

150

150

[mm]

-/320

-/320

-/368

-/368

-/449

-/497

-/551

-/551

1~/3~ TPE [mm]

-/314

-/314

-/314

-/-

-/ -

-/ -

-/ -

-/ -

1~/3~ TP

[mm]

-/197

-/197

-/286

-/286

-/338

-/410

-/433

-/433

1~/3~ TPE [mm]

-/308

-/308

-/308

-/-

-/ -

-/ -

-/ -

-/ -

AE

1~/3~ TPE [mm]

-/210

-/210

-/210

-/ -

-/ -

-/ -

-/ -

-/ -

AF

1~/3~ TPE [mm]

-/210

-/210

-/210

-/-

-/ -

-/ -

-/ -

-/ -

[mm]

350

350

350

350

450

550

550

550

B1

[mm]

295/-

295/-

295/-

295/-

373/-

373/-

373/-

373/-

B2

[mm]

240/-

240/-

240/-

240/-

333/-

333/-

333/-

333/-

[mm]

294/-

294/-

294/-

294/-

388/-

388/-

388/-

388/-

B4

TP

[mm]

294/-

294/-

294/-

-/ -

-/ -

-/ -

-/ -

-/ -

L1

[mm]

800

800

800

800

1000

1000

1000

1000

H1

[mm]

250

250

250

250

250

250

250

250

H2

[mm]

313

313

313

313

352

352

352

352

[mm]

-/1041

-/1081

-/1121

-/1151

-/1315

-/1349

-/1422

-/1532

1~/3~ TPE [mm]

-/1041

-/1081

-/1165

-/-

-/-

-/-

-/-

-/-

H3

TPE

1~/3~ TP

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

119

22
DN 150
4-pole, PN 6, 10, 16

Performance curves/technical data

TP, TPE 150-XXX/4


H
[m]

TP, TPE 150

45

60 Hz
-400/4

40

-360/4

35
30
25
20
15
10
P2
[kW]

50

100 150 200 250 300 350 Q [m/h]

50
40

-400/4

30

-360/4

20
10
0
0
NPSH
[m]
14

50

100 150 200 250 300 350 Q [m/h]


-360/4

12
10
8

-400/4

6
4
2
0
0

50

100 150 200 250 300 350 Q [m/h]

Eta
[%]
85
80
75

-360/4

-400/4

70
65
60
55
50
45
50

100 150 200 250 300 350 Q [m/h]

20

40

60
3

80
4

100
5

Q [l/s]
v [m/s]

TM03 4652 2406

Note: All QH-curves apply to single-head pumps. For further information, see page 81.

120

22
DN 150

TM03 8623 2107

Performance curves/technical data

4-pole, PN 6, 10, 16

Technical data
TP 150

-360/4

-400/4

TPD

TPE

TPED

300

300

Series

IEC size

P2

1~ TP

3~ TP

200

225

1~ TPE

3~ TPE

-/30

-/37

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN

-/-

-/-

PN 16

PN 16

Tmin;Tmax

[C] [-25;120] [-25;120]

D1

[mm]

150

150

[mm]

-/408

-/449

AC
AD

1~/3~ TP

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/-

-/-

-/315

-/338

1~/3~ TPE [mm]

-/-

-/-

AE

1~/3~ TPE [mm]

-/-

-/-

AF

1~/3~ TPE [mm]

-/-

-/-

[mm]

400

450

B1

[mm]

335/-

335/-

B2

[mm]

288/-

288/-

[mm]

335/-

335/-

B4

TP

[mm]

-/-

-/-

L1

[mm]

800

800

H1

[mm]

235

235

H2

[mm]

319

349

[mm]

-/1199

-/1232

-/-

-/-

H3

TPE

1~/3~ TP

1~/3~ TPE [mm]

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

121

22
DN 200
4-pole, PN 6, 10, 16

Performance curves/technical data

TP 200-XXX/4
H
[m]

TP, TPE 200

55

60 Hz

-500/4

50
-440/4

45

-400/4

40
35
30
25
20
15
P2
[kW]
110

100 200 300 400 500 600 700 800Q [m/h]


-500/4

100
90

-440/4

80

-400/4

70
60
50
40
0
NPSH
[m]
14

100 200 300 400 500 600 700 800Q [m/h]

12
10
8
6

-400/4, -440/4, -500/4

4
2
0
Eta
[%]
85

100 200 300 400 500 600 700 800Q [m/h]

-500/4

80
75

-400/4

70

-440/4

65
60
55
50
45
100 200 300 400 500 600 700 800Q [m/h]

0
0

122

50
1

100
2

150
4

200
6

Q [l/s]
7

v [m/s]

TM03 8592 2007

22

TM03 8621 2107

Performance curves/technical data

DN 200
4-pole, PN 6, 10, 16

Technical data
TP 200

-400/4

-440/4

-500/4

TPD

TPE

TPED

300

Series

IEC size

P2

300

300

1~ TP

3~ TP

280

280

315

1~ TPE

3~ TPE

-/75

-/90

-/110

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN

-/-

-/-

-/-

PN 16

PN 16

PN 16

Tmin;Tmax

[C] [-25;120] [-25;120] [-25;120]

D1

[mm]

200

200

200

[mm]

-/551

-/551

-/616

AC
AD

1~/3~ TP

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/ -

-/ -

-/-

-/433

-/433

-/515

1~/3~ TPE [mm]

-/-

-/-

-/-

AE

1~/3~ TPE [mm]

AF

1~/3~ TPE [mm]

[mm]

550

550

660

B1

[mm]

393/-

393/-

393/-

B2

[mm]

328/-

328/-

328/-

[mm]

432/-

432/-

495/-

B4

TP

[mm]

-/-

-/-

-/-

L1

[mm]

900

900

900

H1

[mm]

295

295

295

H2

[mm]

377

377

407

[mm]

-/1492

-/1602

-/1614

-/-

-/-

-/-

H3

TPE

1~/3~ TP

1~/3~ TPE [mm]

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

123

22
DN 200
4-pole, PN 6, 10, 16
Performance curves/technical data

TP 200-XXX/4
H
[m]

TP, TPE 200

80

-770/4

70

-680/4

60 Hz

-600/4

60

-540/4

50

-490/4
-430/4

40
30
20
10
P2
[kW]
160

100 200 300 400 500 600 700 800 Q [m/h]


-770/4

140

-680/4

120
-600/4

100
-540/4
-490/4

80
60

-430/4

40
20
0
NPSH
[m]

100 200 300 400 500 600 700 800 Q [m/h]

10
-430/4, -490/4, -540/4

8
6

-600/4, -680/4, -770/4

4
2
0
0

100 200 300 400 500 600 700 800 Q [m/h]

Eta
[%]
85
80
75
70

-430/4

65

-770/4
-490/4
-540/4 -680/4
-600/4

60
55
50
45
100 200 300 400 500 600 700 800 Q [m/h]

0
0

124

50
1

100
2

150
4

200
6

Q [l/s]
7

v [m/s]

TM03 8593 4108

22

TM03 8622 2107

Performance curves/technical data

DN 200
4-pole, PN 6, 10, 16

Technical data
TP 200

-430/4

-490/4

-540/4

-600/4

-680/4

-770/4

TPD

TPE

TPED

300

Series

IEC size

P2

300

300

300

300

300

1~ TP

3~ TP

250

280

280

315

315

315

1~ TPE

3~ TPE

-/55

-/75

-/90

-/110

-/132

-/160

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN

-/-

-/-

-/-

-/-

-/-

-/-

PN 16

PN 16

PN 16

PN 16

PN 16

PN 16

Tmin;Tmax

[C] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120] [-25;120]

D1

[mm]

200

200

200

200

200

200

[mm]

-/497

-/551

-/551

-/616

-/616

-/616

AC
AD

1~/3~ TP

1~/3~ TPE [mm]


1~/3~ TP

[mm]

-/-

-/-

-/-

-/-

-/-

-/-

-/433

-/433

-/433

-/515

-/515

-/515

1~/3~ TPE [mm]

-/-

-/-

-/-

-/-

-/-

-/-

AE

1~/3~ TPE [mm]

AF

1~/3~ TPE [mm]

[mm]

550

550

550

660

660

660

B1

[mm]

423/-

423/-

423/-

423/-

423/-

423/-

B2

[mm]

368/-

368/-

368/-

368/-

368/-

368/-

[mm]

423/-

432/-

432/-

495/-

495/-

495/-

B4

TP

[mm]

-/-

-/-

-/-

-/-

-/-

-/-

L1

[mm]

1000

1000

1000

1000

1000

1000

H1

[mm]

295

295

295

295

295

295

H2

[mm]

382

382

382

412

412

412

[mm]

-/1424

-/1497

-/1607

-/1619

-/1784

-/1784

-/-

-/-

-/-

-/-

-/-

-/-

H3

TPE

1~/3~ TP

1~/3~ TPE [mm]

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

125

22
DN 200
4-pole, PN 6, 10, 16
Performance curves/technical data

TP 200-XXX/4
H
[m]
22

H
[m]

TP, TPE 200

-210/4

20

-190/4

60 Hz

-360/4

35

18

TP, TPE 200

-390/4

40

60 Hz

-320/4

16

30

-280/4

-140/4

14

-250/4

25
-110/4

12

20

10

-80/4

15

10

4
5

2
0
100

200

300

400

500

Q [m/h]

P2
[kW]
70

24
-210/4

20

20
10

0
NPSH
[m]
18
16
14
12
10
8
6
4
2
0

100

100

200

300

400

500

Q [m/h]

-80/4

-110/4
-140/4
-190/4
-210/4

200

300

400

500

Q [m/h]

-190/4
-140/4
-80/4
-110/4

20

200
40

60
2

300

400

500

Q [m/h]

80 100 120 140 160 Q [l/s]


3

v [m/s]

100 200 300 400 500 600 700 Q [m/h]

100 200 300 400 500 600 700 Q [m/h]

-250/4
-280/4
-320/4
-360/4

-390/4

-390/4
-320/4
-280/4 -360/4
-250/4

0
TM05 0541 1211

100

0
NPSH
[m]
18
16
14
12
10
8
6
4
2
0
Eta
[%]
85
80
75
70
65
60
55
50
45
40

-210/4

126

-320/4
-280/4
-250/4

30

-80/4

Eta
[%]
85
80
75
70
65
60
55
50
45
40

-360/4

40

-110/4

-390/4

50

-140/4

12

100 200 300 400 500 600 700 Q [m/h]

60

-190/4

16

100 200 300 400 500 600 700 Q [m/h]

0 20 40 60 80 100 120 140 160 180 200


0

Q [l/s]
v [m/s]

TM05 0543 1211

P2
[kW]

0
0

22
DN 200

TP
TP
TP
TP
TP

200-80/4
200-110/4
200-140/4
200-190/4
200-210/4

200-250/4
200-280/4
200-320/4
200-360/4
200-390/4

TM05 0663 3212 - TM05 0664 1411

TP
TP
TP
TP
TP

Performance curves/technical data

4-pole, PN 6, 10, 16

Technical data
TP 200

-80/4

-110/4

-140/4

-190/4

-210/4

-250/4

-280/4

-320/4

-360/4

TPD

-390/4
-

TPE

TPED

Series

300

300

300

300

300

300

300

300

300

300

IEC size

P2

1~ TP

3~ TP

132

160

160

180

180

200

225

225

250

280
-

1~ TPE

3~ TPE

132

160

160

180

-/7.5

-/11

-/15

-/18.5

-/22

-/30

-/37

-/45

-/55

-/75

1~/3~ TP

[kW]

1~/3~ TPE [kW]

PN

-/7.5

-/11

-/15

-/18.5

-/ -

-/ -

-/ -

-/ -

-/ -

-/ -

PN16

PN16

PN16

PN16

PN16

PN16

PN16

PN16

PN16

PN16

Tmin;Tmax

[C] [-25.120] [-25.120] [-25.120] [-25.120] [-25.120] [-25.120] [-25.120] [-25.120] [-25.120] [-25.120]

D1

[mm]

200

200

200

200

200

200

200

200

150

150

[mm]

-/267

-/320

-/320

-/368

-/368

-/408

-/449

-/449

-/497

-/551

AC
AD

1~/3~ TP

1~/3~ TPE [mm]

-/260

-/314

-/314

-/314

-/ -

-/ -

-/ -

-/ -

-/ -

-/ -

1~/3~ TP

[mm]

-/167

-/197

-/197

-/286

-/286

-/315

-/338

-/338

-/410

-/433

1~/3~ TPE [mm]

-/213

-/308

-/308

-/308

-/ -

-/ -

-/ -

-/ -

-/ -

-/ -

AE

1~/3~ TPE [mm]

-/145

-/210

-/210

-/210

-/ -

-/ -

-/ -

-/ -

-/ -

-/ -

AF

1~/3~ TPE [mm]

-/145

-/210

-/210

-/210

-/ -

-/ -

-/ -

-/ -

-/ -

-/ -

[mm]

300

350

350

350

350

400

450

450

550

550

B1

[mm]

296/-

363/-

363/-

363/-

363/-

348/-

348/-

348/-

348/-

348/-

B2

[mm]

237/-

283/-

283/-

283/-

283/-

288/-

288/-

288/-

288/-

288/-

[mm]

296/-

359/-

359/-

359/-

359/-

363/-

363/-

363/-

363/-

363/-

B4

TP

[mm]

296/-

359/-

359/-

359/-

-/-

-/-

-/-

-/-

-/-

-/-

L1

[mm]

900

900

900

900

900

900

900

900

900

900

H1

[mm]

280

280

280

280

280

280

280

280

280

280

H2

[mm]

-/336

-/336

-/336

-/336

-/336

-/331

-/361

-/361

-/361

-/361

[mm]

-/1026

-/1094

-/1134

-/1130

-/1160

-/1256

-/1298

-/1358

-/1397

-/1470

1~/3~ TPE [mm]

-/1026

-/1094

-/1134

-/1174

-/ -

-/ -

-/ -

-/ -

-/ -

-/ -

H3

TPE

1~/3~ TP

The dimension before the slash applies to the single-head pump and the dimension after the slash applies to the twin-head pump.

127

22
DN 250
4-pole, PN 6, 10
Performance curves/technical data

TP 250-XXX/4

H
[m]
60

TP 250

-580/4

55

-530

60 Hz

/4

50
-450/4

45
40
35
30
25
20
15
P2
[kW]

200

400

600

800

1000

Q [m/h]

120

-580/4

100
-530/4

80
-450/4

60
40
20
NPSH
[m]
11

200

400

600

800

1000

Q [m/h]

200

400

600

800

1000

Q [m/h]

10
9
8
7
6
5
4
Eta
[%]
85

-580/4

80
-450/4

75

-530/4

70
65
60
55
50
45

128

200

400

600

800

100

200

1000
300
6

Q [m/h]
Q [l/s]
v [m/s]

TM02 6826 0504

22
Performance curves/technical data

DN 250
4-pole, PN 6, 10

H3

AC

H1

H2

D1S

D1D

TM02 8349 5004

B7

B2
B1

B4

C2

Rp 3/8

B9

C7

AD
B8

C8

C8

L2

L3
L1

Rp 3/8

Technical data
TP 250

-450/4

-530/4

-580/4

TPD

TPE

TPED

400

Series

IEC size

P2

400

400

1~ TP

3~ TP

280 M

315 S

315 M

1~ TPE

3~ TPE

90

110

132

PN 10

PN 10

PN 10

[kW]

PN
Tmin;Tmax

[C] [-25;120] [-25;120] [-25;120]

D1D/D1S

[mm] 250/300 250/300 250/300

AC

[mm]

555

610

610

AD

[mm]

432

495

495

[mm]

550

660

660

B1

[mm]

223

223

223

B2

[mm]

635

635

635

B4

[mm]

223

223

223

B7

[mm]

647

647

647

B8

[mm]

300

300

300

B9

[mm]

335

335

335

C2

[mm]

580

580

580

C7

[mm]

520

520

520

C8

[mm]

50

50

50

[mm]

20

20

20

L1

[mm]

950

950

950

L2

[mm]

190

190

190

L3

[mm]

620

620

620

H1

[mm]

310

310

310

H2

[mm]

368

398

398

H3

[mm]

1608

1640

1800

129

22
DN 100
2-pole, PN 25

TP, 2-pole, PN 25
TP 100-XXX/2
H
[m]

H
[m]
140

TP 100

-1350/2

130

240

60 Hz

220

-1250/2

120

60 Hz

-2100/2

200
-1100/2

110
100
90

-1000/2

180

-1700/2

160

-1560/2

140

80

-1450/2

120

70
60

100

50

80
60

40
P2
[kW]

TP 100

-2350/2

50 100 150 200 250 300 350

Q [m/h]

P2
[kW]

140

50 100 150 200 250 300 350

240

-2350/2

-1350/2

120

200

-1250/2

100

-2100/2

-1100/2

80

160

-1700/2

-1000/2

60

120

-1560/2
-1450/2

40
80

20

40

0
NPSH
[m]
16

50 100 150 200 250 300 350 400Q [m/h]

NPSH
[m]
16

12

12

10

10

50 100 150 200 250 300 350

Q [m/h]

50 100 150 200 250 300 350 400Q [m/h]

2
0

50 100 150 200 250 300 350 400Q [m/h]

Eta
[%]

75

75

70

70
-1350/2
-1250/2
-1100/2
-1000/2

65
60

65
60

55

55

50

50

45

45

40

40

20

40
4

60
6

80
8

100
10

12

Q [l/s]
v [m/s]

-2350/2
-2100/2
-1700/2
-1560/2
-1450/2

50 100 150 200 250 300 350 400Q [m/h]


TM02 6853 0504

130

14

14

Eta
[%]

Q [m/h]

50 100 150 200 250 300 350 400Q [m/h]

20

40
4

60
6

80
8

100
10

12

Q [l/s]
v [m/s]

TM02 6854 0504

Performance curves/technical data

22. Performance curves/technical data

22
Performance curves/technical data

DN 100
2-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

B1

AD

B4

C3

B6
C4

C9

B5

B8

B2

Technical data
TP 100

-1000/2 -1100/2 -1250/2 -1350/2 -1450/2 -1560/2 -1700/2 -2100/2 -2350/2

TPD

TPE

TPED

400

Series

IEC size

P2

400

400

400

400

400

400

400

400

1~ TP

3~ TP

280 S

280 M

315 S

315 M

315 S

315 M

315 L

315 L

315

1~ TPE

3~ TPE

[kW]

75

90

110

132

110

132

160

200

250

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

PN
Tmin;Tmax

D1D/D1S

[mm] 100/125 100/125 100/125 100/125 100/125 100/125 100/125 100/125 100/125

AC

[mm]

540

555

610

610

610

610

610

610

710

AD

[mm]

433

432

495

495

495

495

495

495

690

[mm]

550

550

660

660

800

800

800

800

800

B1

[mm]

180

180

180

180

180

180

180

180

180

B2

[mm]

407

407

407

407

425

425

425

425

425

B4

[mm]

227

227

320

320

312

312

312

312

490

B5

[mm]

360

360

360

360

360

360

360

360

360

B6

[mm]

335

335

335

335

335

335

335

335

335

B7

[mm]

467

467

522

522

600

600

600

600

600

B8

[mm]

192

192

192

192

200

200

200

200

200

B9

[mm]

215

215

215

215

225

225

225

225

225

C3

[mm]

320

320

320

320

320

320

320

320

320

C4

[mm]

295

295

295

295

295

295

295

295

295

C9

[mm]

489

489

489

489

606

606

606

606

606

[mm]

20

20

20

20

20

20

20

20

20

L1

[mm]

543

543

543

543

660

660

660

660

660

H1

[mm]

160

160

160

160

170

170

170

170

170

H2

[mm]

315

315

336

336

303

303

303

303

303

H3

[mm]

1295

1405

1428

1588

1405

1565

1565

1705

1703

131

22
DN 100
4-pole, PN 25

TP, 4-pole, PN 25
TP 100-XXX/4
H
[m]

H
[m]
36

-360/4

TP 100

-330/4

60 Hz

32

60

-590/4

55

-530/4

-250/4

-450/4

45

24

-420/4

-210/4

20

40

16

35

12

30

25
20

4
0

20 40 60 80 100 120 140 160 180

Q [m/h]

18

P2
[kW]

-330/4

Q [m/h]

-590/4

-530/4

25

12

20

10

-450/4
-420/4

-250/4

15

8
-210/4

10
5

4
0

20 40 60 80 100 120 140 160 180

Q [m/h]

NPSH
[m]

20 40 60 80 100 120 140 160 180

Q [m/h]

20 40 60 80 100 120 140 160 180

Q [m/h]

0
0

20 40 60 80 100 120 140 160 180

Q [m/h]

Eta
[%]
80

-450/4

75

-360/4

70

70

65
60

65

-330/4

-420/4

60

55

-590/4

55

50
45

45

40

40

10

20
2

30
3

40
4

50
5

Q [m/h]
Q [l/s]
v [m/s]

TM02 6858 0504

20 40 60 80 100 120 140 160 180

-530/4

50

-210/4 -250/4

132

20 40 60 80 100 120 140 160 180

30

14

Eta
[%]
75

35

-360/4

16

NPSH
[m]

60 Hz

50

28

P2
[kW]

TP 100

20 40 60 80 100 120 140 160 180

10

20
2

30
3

40
4

50
5

Q [m/h]
Q [l/s]
v [m/s]

TM02 6859 0504

Performance curves/technical data

22. Performance curves/technical data

22
DN 100

Performance curves/technical data

4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

B1
AD

C9

B4

C3

B6
C4

B5

B8

B2

Technical data
TP 100

-210/4

-250/4

-330/4

-360/4

-420/4

-450/4

-530/4

-590/4

TPD

TPE

TPED

400

Series

IEC size

P2

400

400

400

400

400

400

400

1~ TP

3~ TP

132 M

160 M

160 L

180 M

180 M

180 L

200 L

225 S

1~ TPE

3~ TPE

[kW]

7.5

11

15

18.5

18.5

22

30

37

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

PN
Tmin;Tmax
D1D/D1S

[mm] 100/125 100/125 100/125 100/125 100/125 100/125 100/125 100/125

AC

[mm]

307

376

321

363

363

363

402

442

AD

[mm]

192

161

133

262

262

262

300

325

[mm]

400

400

400

400

450

450

450

550

B1

[mm]

180

180

180

180

180

180

180

180

B2

[mm]

407

407

407

407

425

425

425

425

B4

[mm]

180

180

180

180

180

180

180

180

B5

[mm]

360

360

360

360

360

360

360

360

B6

[mm]

335

335

335

335

335

335

335

335

B7

[mm]

401

401

401

401

429

429

429

475

B8

[mm]

192

192

192

192

200

200

200

200

B9

[mm]

225

225

225

225

225

225

225

225

C3

[mm]

320

320

320

320

320

320

320

320

C4

[mm]

295

295

295

295

295

295

295

295

C9

[mm]

489

489

489

489

606

606

606

606

[mm]

20

20

20

20

20

20

20

20

L1

[mm]

543

543

543

543

660

660

660

660

H1

[mm]

160

160

160

160

170

170

170

170

H2

[mm]

285

285

285

285

270

270

270

300

H3

[mm]

843

945

973

1004

999

1050

1107

1119

133

22
DN 125
4-pole, PN 25

Performance curves/technical data

TP 125-XXX/4

H
[m]

TP 125

40

H
[m]

60 Hz

-370/4

36

TP 125

70

32

-310/4

28

-270/4

60 Hz
-620/4

60

-570/4
-500/4

50

24

-440/4

-240/4

20

40

16

-350/4

30

12
20

8
P2
[kW]

40

80 120 160 200 240 280

Q [m/h]

10
P2
[kW]

30

40 80 120 160 200 240 280 320

-620/4
-570/4

40

20

-310/4

-500/4

30

-270/4

15

Q [m/h]

50

-370/4

25

-240/4

-440/4

20

-350/4

10
10

5
0

40

80 120 160 200 240 280

Q [m/h]

NPSH
[m]

Q [m/h]

40 80 120 160 200 240 280 320

Q [m/h]

4
3

40

80 120 160 200 240 280

Q [m/h]
Eta
[%]
80

75

-270/4

75

-370/4

70

70
-310/4

65

65

-240/4

60

60

55

55

50

50

45

45

40

40

40

0
0

80 120 160 200 240 280


20

40
2

60
4

80
5

Q [l/s]
7 v [m/s]

-350/4
-440/4

-620/4

-500/4 -570/4

Q [m/h]
TM02 6860 0504

134

40 80 120 160 200 240 280 320

10

Eta
[%]
80

40 80 120 160 200 240 280 320

0
0

20
1

40
2

60
4

80
5

Q [m/h]
100 Q [l/s]

v [m/s]

TM02 6861 0504

NPSH
[m]

22
DN 125

Performance curves/technical data

4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

TM02 8350 5004

B7

B1
AD

C9

B4

C3

B6
C4

B5

B8

B2

Technical data
TP 125

-240/4

-270/4

-310/4

-370/4

-350/4

-440/4

-500/4

-570/4

-620/4

TPD

TPE

TPED

400

Series

IEC size

P2

400

400

400

400

400

400

400

400

1~ TP

3~ TP

160 L

180 M

180 L

200 L

180 L

200 L

225 S

225 M

250 M

1~ TPE

3~ TPE

[kW]

15

18.5

22

30

22

30

37

45

55

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

PN
Tmin;Tmax
D1D/D1S

[mm] 125/150 125/150 125/150 125/150 125/150 125/150 125/150 125/150 125/150

AC

[mm]

321

363

363

402

363

402

442

442

495

AD

[mm]

133

262

262

300

262

300

325

325

392

[mm]

400

400

400

400

450

450

550

550

550

B1

[mm]

200

200

200

200

200

200

200

200

200

B2

[mm]

430

430

430

430

451

451

451

451

451

B4

[mm]

200

200

200

200

200

200

200

200

200

B5

[mm]

400

400

400

400

400

400

400

400

400

B6

[mm]

360

360

360

360

360

360

360

360

360

B7

[mm]

423

423

423

423

468

467

499

499

499

B8

[mm]

200

200

200

200

224

224

224

224

224

B9

[mm]

230

230

230

230

227

227

227

227

227

C3

[mm]

360

360

360

360

360

360

360

360

360

C4

[mm]

320

320

320

320

320

320

320

320

320

C9

[mm]

536

536

536

536

606

606

606

606

606

[mm]

20

20

20

20

20

20

20

20

20

L1

[mm]

590

590

590

590

660

660

660

660

660

H1

[mm]

185

185

185

185

180

180

180

180

180

H2

[mm]

287

287

287

287

283

283

313

313

313

H3

[mm]

1000

1031

1082

1140

1073

1130

1142

1202

1310

135

22
DN 150
4-pole, PN 25

Performance curves/technical data

TP 150-XXX/4

H
[m]

TP 150

100

-930/4

60 Hz

90
-800/4

80

-710/4

70
60
50

-490/4

40

-450/4
-370/4

30

-330/4

20
10
P2
[kW]

50 100 150 200 250 300 350 400 450

Q [m/h]

120

-930/4

100

-800/4
-710/4

80
60

-490/4
-450/4
-370/4
-330/4

40
20
0
NPSH
[m]

50 100 150 200 250 300 350 400 450

Q [m/h]

50 100 150 200 250 300 350 400 450

Q [m/h]

7
6
5
4
3
2
1

-330/4
-930/4
-800/4
-710/4

0
0
0

136

-490/4
-450/4

-370/4

50 100 150 200 250 300 350 400 450


20

40
2

60

80
4

100

120
6

Q [m/h]
140Q [l/s]
v [m/s]

TM02 6863 0504

Eta
[%]
85
80
75
70
65
60
55
50
45
40

22
DN 150

Performance curves/technical data

4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

B1
AD

C9

B4

C3

B6
C4

B5

B8

B2

Technical data
TP 150

-330/4

-370/4

-450/4

-490/4

-710/4

-800/4

-930/4

TPD

TPE

TPED

400

Series

IEC size

P2

400

400

400

400

400

400

1~ TP

3~ TP

200 L

225 S

225 M

250 M

280 M

315 S

315 M

1~ TPE

3~ TPE

[kW]

30

37

45

55

90

110

132

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

PN
Tmin;Tmax
D1D/D1S

[mm] 150/200 150/200 150/200 150/200 150/200 150/200 150/200

AC

[mm]

402

442

442

495

555

610

610

AD

[mm]

300

325

325

392

432

495

495

[mm]

450

550

550

550

550

660

660

B1

[mm]

230

230

230

230

235

235

235

B2

[mm]

504

504

504

504

575

575

575

B4

[mm]

230

230

230

230

235

252

252

B5

[mm]

460

460

460

460

470

470

470

B6

[mm]

400

400

400

400

410

410

410

B7

[mm]

518

518

518

518

584

590

590

B8

[mm]

229

229

229

229

260

260

260

B9

[mm]

275

275

275

275

315

315

315

C3

[mm]

420

420

420

420

420

420

420

C4

[mm]

360

360

360

360

360

360

360

C9

[mm]

676

676

676

676

823

823

823

[mm]

20

20

20

20

20

20

20

L1

[mm]

740

740

740

740

900

900

900

H1

[mm]

225

225

225

225

250

250

250

H2

[mm]

293

323

323

323

325

355

355

H3

[mm]

1185

1197

1257

1365

1505

1537

1697

137

22
DN 200
4-pole, PN 25

Performance curves/technical data

TP 200-XXX/4

H
[m]
H
[m]

90

60 Hz

50
-520/4

45
40

-760/4

70

-670/4

60

-350/4

50

25

40

20

30

15

20

10
0

P2
[kW]

100 200 300 400 500 600 700 Q [m/h]

-840/4

80

-370/4

35
30

60 Hz

-930/4

TP 200

-560/4

55

P2
[kW]

TP 200

100

0 100 200 300 400 500 600 700 800

Q [m/h]

200
-930/4

80

160

-560/4

70

120

-520/4

60

-760/4
-670/4

80

50
40

-370/4
-350/4

30

40
0

20
NPSH
[m]

-840/4

NPSH
[m]

100 200 300 400 500 600 700 Q [m/h]

0 100 200 300 400 500 600 700 800

Q [m/h]

0 100 200 300 400 500 600 700 800

Q [m/h]

12

10

Eta
[%]
80

100 200 300 400 500 600 700 Q [m/h]

Eta
[%]
85
80
75
70
65
60
55
50
45
40

-520/4

75
70
65
60

-370/4

-560/4

-350/4

55
50
45
40

0
0

138

100 200 300 400 500 600 700 Q [m/h]


50

100
2

150
4

200
6

Q [l/s]
v [m/s]

-670/4

-930/4
-840/4

0 100 200 300 400 500 600 700 800


TM02 6864 0504

-760/4

0
0

50

100
2

150
4

200
6

Q [m/h]
250 Q [l/s]
8 v [m/s]

TM02 6865 0504

22
DN 200

Performance curves/technical data

4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

B1
AD

C9

B4

C3

B6
C4

B5

B8

B2

Technical data
TP 200

-350/4

-370/4

-520/4

-560/4

-670/4

-760/4

-840/4

-930/4

TPD

TPE

TPED

400

Series

IEC size

P2

400

400

400

400

400

400

400

1~ TP

3~ TP

225 M

250 M

280 S

280 M

315 S

315 M

315 M

315 L

1~ TPE

3~ TPE

[kW]

45

55

75

90

110

132

160

200

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

PN
Tmin;Tmax
D1D/D1S

[mm] 200/250 200/250 200/250 200/250 200/250 200/250 200/250 200/250

AC

[mm]

442

495

555

555

610

610

610

610

AD

[mm]

325

392

432

432

495

495

495

495

[mm]

450

550

550

550

660

660

660

660

B1

[mm]

260

260

260

260

268

268

268

268

B2

[mm]

560

560

560

560

640

640

640

640

B4

[mm]

260

260

260

260

268

268

268

268

B5

[mm]

520

520

520

520

535

535

535

535

B6

[mm]

460

460

460

460

470

470

470

470

B7

[mm]

572

572

573

573

645

645

645

645

B8

[mm]

260

260

260

260

300

300

300

300

B9

[mm]

300

300

300

300

340

340

340

340

C3

[mm]

480

480

480

480

485

485

485

485

C4

[mm]

420

420

420

420

420

420

420

420

C9

[mm]

766

766

766

766

1013

1013

1013

1013

[mm]

20

20

20

20

20

20

20

20

L1

[mm]

830

830

830

830

1100

1100

1100

1100

H1

[mm]

250

250

250

250

290

290

290

290

H2

[mm]

308

338

338

338

357

357

357

357

H3

[mm]

1267

1405

1408

1518

1579

1739

1739

1879

139

22
DN 250
4-pole, PN 25

H
[m]
H
[m]

45

100

60 Hz

-500/4

70

35

60

30

50

25

40

20

30

15
P2
[kW]

400

600

800

1000

P2
[kW]

Q [m/h]

200

400

600

800 1000 1200 Q [m/h]

-1020/4

-910/4

200

100

-800/4

160

-500/4

90

-720/4

120

80
-430/4

70

80

60

40

50
0

200

400

600

800

1000

NPSH
[m]
13

Q [m/h]

200

400

600

800 1000 1200 Q [m/h]

200

400

600

800 1000 1200 Q [m/h]

12

11

11

10

10

8
7

5
0

200

400

600

800

1000

Q [m/h]

Eta
[%]
85
80
75
70
65
60
55
50
45
40

-550/4
-430/4
-500/4

200

0
0

400

600

100
1

800

1000

200
3

300
5

Q [l/s]
v [m/s]

-800/4

-720/4

-1020/4
-910/4

Q [m/h]
TM02 6866 0504

140

240

-550/4

110

Eta
[%]
85
80
75
70
65
60
55
50
45
40

-720/4

280

120

NPSH
[m]
12

-800/4

80

40

200

-910/4

90

-430/4

60 Hz

-1020/4

TP 250

-550/4

55
50

TP 250

110

200

0
0

400

600

100
1

800 1000 1200 Q [m/h]

200
3

300
5

Q [l/s]
7

v [m/s]

TM02 6867 0504

Performance curves/technical data

TP 250-XXX/4

22
DN 250

Performance curves/technical data

4-pole, PN 25

H3

AC

H2

H1

Rp 1/2

D1D

D1S

Rp 1/2

B9

L1

B7

TM02 8350 5004

B1
AD

C9

B4

C3

B6
C4

B5

B8

B2

Technical data
TP 250

-430/4

-500/4

-550/4

-720/4

-800/4

-910/4

-1020/4

TPD

TPE

TPED

400

Series

IEC size

P2

400

400

400

400

400

400

1~ TP

3~ TP

280 M

315 S

315 M

315 M

315 L

315

315

1~ TPE

3~ TPE

[kW]

90

110

132

160

200

250

315

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

PN 25

[C]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

[0;150]

PN
Tmin;Tmax
D1D/D1S

[mm] 250/300 250/300 250/300 250/300 250/300 250/300 250/300

AC

[mm]

555

610

610

610

610

710

710

AD

[mm]

432

495

495

495

495

690

690

[mm]

550

660

660

660

660

800

800

B1

[mm]

303

303

303

303

303

303

303

B2

[mm]

650

650

650

700

700

700

700

B4

[mm]

303

303

303

303

303

360

360

B5

[mm]

605

605

605

605

605

605

605

B6

[mm]

540

540

540

540

540

540

540

B7

[mm]

647

647

647

720

720

730

730

B8

[mm]

300

300

300

330

330

330

330

B9

[mm]

350

350

350

370

370

370

370

C3

[mm]

550

550

550

550

550

550

550

C4

[mm]

485

485

485

485

485

485

485

C9

[mm]

855

855

855

1106

1106

1106

1106

[mm]

24

24

24

24

24

24

24

L1

[mm]

950

950

950

1200

1200

1200

1200

H1

[mm]

300

300

300

350

350

350

350

H2

[mm]

368

398

398

373

373

413

413

H3

[mm]

1598

1630

1790

1815

1955

1993

1993

141

23
Weights and shipping volume
142

TP, TPD, TPE

23. Weights and shipping volume


TP, TPD, TPE, 2-pole, PN 6, 10, 16
Connection
Pump type

TP 32-80/2
TP 32-160/2
TP 32-220/2
TP 32-260/2
TP 32-330/2
TP, TPD 32-300/2
TP, TPD 32-360/2
TP, TPD 32-450/2
TP, TPD 32-550/2
TP, TPD 32-680/2
TP, TPD 32-820/2
TP 40-80/2
TP 40-160/2
TP 40-240/2
TP 40-270/2
TP 40-330/2
TP 40-390/2
TP, TPD 40-370/2
TP, TPD 40-450/2
TP, TPD 40-550/2
TP, TPD 40-740/2
TP, TPD 40-850/2
TP, TPD 40-930/2
TP 50-80/2
TP 50-160/2
TP 50-240/2
TP, TPD 50-250/2
TP, TPD 50-300/2
TP, TPD 50-350/2
TP, TPD 50-410/2
TP, TPD 50-720/2
TP, TPD 50-790/2
TP, TPD 50-880/2
TP, TPD 50-1050/2
TP 65-80/2
TP 65-160/2
TP 65-240/2
TP, TPD 65-220/2
TP, TPD 65-260/2
TP, TPD 65-340/2
TP, TPD 65-390/2
TP, TPD 65-480/2
TP, TPD 65-540/2
TP, TPD 65-630/2
TP, TPD 65-740/2
TP, TPD 65-910/2
TP, TPD 65-920/2
TP, TPD 65-1050/2
TP 80-160/2
TP, TPD 80-200/2
TP, TPD 80-240/2
TP, TPD 80-290/2
TP, TPD 80-330/2
TP, TPD 80-400/2
TP, TPD 80-480/2
TP, TPD 80-530/2
TP, TPD 80-640/2
TP, TPD 80-750/2
TP, TPD 100-230/2
TP, TPD 100-300/2
TP, TPD 100-370/2
TP, TPD 100-350/2

D1D

D1 S

DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 100
DN 100
DN 100
DN 100

DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 32
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 100
DN 100
DN 100
DN 100

Weights
Net [kg]

Shipping volume
[m3]

Gross [kg]

TP/TPD

TPE

TP/TPD

TPE

TP/TPD

TPE

17/19/24/26/32/58/118
69/125
74/150
89/180
91/184
140/283
19/21/26/38/40/46/74/153
89/183
91/187
139/286
151/309
161/329
24/28/35/53/109
65/116
71/144
85/174
158/324
168/345
198/403
352/713
29/37/39/69/124
74/149
88/179
90/182
148/309
160/331
170/352
199/410
344/701
336/679
361/734
52/78/157
93/187
95/191
151/307
162/329
178/351
207/409
359/713
369/722
110/230
155/319
168/344
200/394

51
71
77
94
105
174
77
94
105
174
177
201
47
66
74
90
184
209
222
77
93
94
196
200
229
241
222
80
97
108
183
187
217
230
123
188
193
238

18/20/27/29/35/64/135
76/142
81/167
104/197
107/201
157/313
21/25/29/42/44/49/81/183
104/200
106/204
156/316
168/339
178/359
26/31/38/59/126
70/133
76/161
101/191
175/354
185/375
216/453
370/763
32/41/43/74/141
79/166
104/196
105/199
165/339
177/361
187/382
218/460
363/751
342/787
380/784
57/90/174
105/204
107/208
172/337
182/359
199/381
228/459
380/344
389/764
124/280
177/369
190/394
201/445

58
78
84
112
124
195
84
112
124
195
198
223
52
72
79
108
206
230
243
82
111
113
218
222
251
263
241
94
118
129
205
208
238
251
145
210
214
240

0.04/0.04/0.06/0.06/0.06/0.2176/0.3912
0.2176/0.4584
0.2176/0.4584
0.2176/0.4584
0.2176/0.4584
0.7248/0.6507
0.04/0.06/0.06/0.06/0.06/0.06/0.2176/0.6507
0.2176/0.3912
0.2176/0.3912
0.7248/0.6507
0.7248/0.6507
0.7248/0.6507
0.04/0.06/0.15/0.184/0.4584
0.184/0.4584
0.184/0.4584
0.184/0.4584
0.7248/0.6507
0.7248/0.6507
0.7248/1.524
0.7248/1.524
0.06/1.524
0.08/0.08/0.184/0.4584
0.184/0.2632
0.184/0.2632
0.184/0.4584
0.7248/0.6507
0.7248/0.6507
0.7248/0.6507
0.7248/1.524
0.7248/1.524
0.580/1.800
0.7248/1.524
0.15/0.184/0.4584
0.184/0.4584
0.184/0.4584
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.7248/1.524
0.9696/1.524
0.7248/1.524

0.2176
0.2176
0.2176
0.2176
0.2176
0.2176
0.2176
0.2176
0.7248
0.7248
0.7248
0.184
0.184
0.184
0.184
0.7248
0.7248
0.7248
0.184
0.184
0.184
0.184
0.7248
0.7248
0.7248
0.7248
0.7248
0.7248
0.7248
0.7248
0.7248
0.7248
0.7248
0.7248
0.7248
0.9696
0.7248

Connection
Pump type

TP,
TP,
TP,
TP,

TPD
TPD
TPD
TPD

100-380/2
100-530/2
100-630/2
100-700/2

D1D
DN
DN
DN
DN

100
100
100
100

Weights

D1 S
DN
DN
DN
DN

100
100
100
100

Net [kg]

Weights and shipping volume

23

TP, TPD, TPE

Shipping volume
[m3]

Gross [kg]

TP/TPD

TPE

TP/TPD

TPE

TP/TPD

TPE

230/455
389/775
405/808
428/854

252
-

231/505
430/833
447/865
444/927

254
-

0.9696/1.524
0.7973/1.800
0.7973/1.800
0.7973/1.800

0.9696

The value before the slash applies to the single-head pump and the value after the slash applies to the twin-head pump.

143

23
Weights and shipping volume
144

TP, TPD, TPE

TP, TPD, TPE, 4-pole, PN 6, 10, 16


Connection
Pump type

TP 32-40/4
TP 32-80/4
TP, TPD 32-120/4
TP, TPD 32-140/4
TP, TPD 32-190/4
TP 40-40/4
TP 40-80/4
TP, TPD 40-120/4
TP, TPD 40-160/4
TP, TPD 40-190/4
TP, TPD 40-220/4
TP 50-40/4
TP 50-80/4
TP, TPD 50-110/4
TP, TPD 50-120/4
TP, TPD 50-140/4
TP, TPD 50-190/4
TP, TPD 50-240/4
TP, TPD 50-270/4
TP, TPD 50-340/4
TP 65-40/4
TP 65-80/4
TP, TPD 65-130/4
TP, TPD 65-150/4
TP, TPD 65-190/4
TP, TPD 65-230/4
TP, TPD 65-310/4
TP, TPD 65-330/4
TP 80-40/4
TP 80-80/4
TP, TPD 80-110/4
TP, TPD 80-150/4
TP, TPD 80-170/4
TP, TPD 80-230/4
TP, TPD 80-280/4
TP, TPD 80-340/4
TP, TPD 80-410/4
TP, TPD 80-460/4
TP, TPD 80-510/4
TP 100-40/4
TP 100-80/4
TP, TPD 100-100/4
TP, TPD 100-130/4
TP, TPD 100-150/4
TP, TPD 100-170/4
TP, TPD 100-200/4
TP, TPD 100-240/4
TP, TPD 100-260/4
TP, TPD 100-290/4
TP, TPD 100-340/4
TP, TPD 100-350/4
TP, TPD 100-390/4
TP, TPD 100-470/4
TP 125-100/4
TP 125-120/4
TP 125-140/4
TP, TPD 125-130/4
TP, TPD 125-160/4
TP, TPD 125-230/4
TP, TPD 125-320/4
TP, TPD 125-360/4
TP, TPD 125-430/4
TP, TPD 125-490/4
TP 150-170/4
TP, TPD 150-180/4

D1D

D1S

DN 32
DN 32
DN 32
DN 32
DN 32
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 150
DN 150

DN 32
DN 32
DN 32
DN 32
DN 32
DN 40
DN 40
DN 40
DN 40
DN 40
DN 40
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 50
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 65
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 80
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 100
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 125
DN 150
DN 150

Weights
Net [kg]

Shipping volume
[m3]

Gross [kg]

TP/TPD

TPE

TP/TPD

TPE

TP/TPD

TPE

26/26/46/94
47/97
53/116
20/25/47/99
53/119
56/126
66/142
22/27/55/117
62/136
64/143
74/160
79/167
78/194
112/230
32/41/66/150
75/166
81/173
79/202
113/237
124/258
49/45/79/165
94/185
101/199
182/369
192/390
225/452
240/474
298/590
316/634
54/61/114/230
140/282
148/337
157/316
232/484
264/544
220/323
275/567
333/682
396/720
349/714
440/896
129/144/150/203/432
213/454
264/597
360/723
675/754
464/933
509/1021
235/321/641

86
52
65
74
61
73
82
79
99
111
74
84
81
100
112
140
84
93
106
180
209
238
258
297

29/29/52/111
53/114
59/134
22/28/53/116
59/149
62/143
72/159
25/30/61/136
68/156
70/162
80/179
86/186
84/213
127/250
35/44/72/167
82/183
87/190
86/217
130/267
141/288
52/49/92/182
108/204
115/119
184/419
194/440
227/502
242/525
300/622
318/666
59/67/117/280
142/333
164/420
158/367
234/534
266/594
238/406
278/617
375/732
414/828
366/746
457/909
148/163/169/223/482
234/504
281/705
380/781
396/812
485/990
509/1035
408/341/692

92
59
71
81
67
79
89
86
105
129
81
91
88
107
131
161
98
107
120
183
212
240
278
315

0.04/0.04/0.1632/0.3912
0.1632/0.3912
0.2176/0.3912
0.04/0.06/0.1632/0.4584
0.2176/0.4584
0.1632/0.4584
0.2176/0.4584
0.04/0.06/0.16/0.497
0.2176/0.5184
0.2176/0.5184
0.2176/0.5184
0.2176/0.5184
0.2176/0.5184
0.2176/0.5184
0.06/0.08/0.2176/0.4584
0.2176/0.4584
0.2176/0.4584
0.2176/0.4584
0.7248/0.4584
0.7248/0.6507
0.08/0.08/0.2176/0.4584
0.2176/0.5184
0.2176/0.6507
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.9696/1.524
0.151/0.191/0.7248/1.524
0.7248/1.524
0.390/1.520
0.7248/1.524
0.9696/1.524
0.9696/1.524
0.960/1.520
0.9696/1.524
0.9696/1.524
0.960/1.800
0.9696/1.524
0.9696/1.800
0.969/0.969/0.969/0.9696/1.524
0.9696/1.524
0.960/1.520
0.9696/1.800
0.9696/1.800
1.524/1.800
1.524/1.800
2.3/0.9696/1.524

0.2176
0.2176
0.2176
0.2176
0.2176
0.2176
0.2176
0.2176
0.2176
0.7248
0.2176
0.2176
0.2176
0.2176
0.7248
0.2176
0.7248
0.7248
0.9696
0.9696
0.9696
0.9696
0.9696
0.9696
0.9696
0.9696
0.390
0.9696
0.9696
0.9696
0.960
0.9696
0.9696
0.9696
0.969
0.969
0.969
0.9696
0.9696
0.960
0.9696
0.9696
2.3
0.9696

113
144
155
155
249
276
226
293
332
133
148
160
201
230
326
358
254
339

116
147
171
157
269
293
244
313
352
152
171
179
221
250
343.2
378
427
359

Connection
Pump type

TP 150-190/4
TP, TPD 150-210/4
TP 150-230/4
TP, TPD 150-240/4
TP 150-250/4
TP, TPD 150-300/4
TP, TPD 150-340/4
TP 150-360/4
TP 150-380/4
TP 150-400/4
TP 150-420/4
TP 150-440/4
TP 150-480/4
TP 150-490/4
TP 150-550/4
TP 150-610/4
TP 150-700/4
TP 200-80/4
TP 200-110/4
TP 200-140/4
TP 200-190/4
TP 200-210/4
TP 200-250/4
TP 200-280/4
TP 200-320/4
TP 200-360/4
TP 200-390/4
TP 200-400/4
TP 200-430/4
TP 200-440/4
TP 200-490/4
TP 200-500/4
TP 200-540/4
TP 200-600/4
TP 200-680/4
TP 200-770/4
TP 250-450/4
TP 250-530/4
TP 250-580/4

D1D
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN

150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
250
250
250

Weights

D1S
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN

150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
150
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
200
300
300
300

Net [kg]

Weights and shipping volume

23

TP, TPD, TPE

Shipping volume
[m3]

Gross [kg]

TP/TPD

TPE

TP/TPD

TPE

TP/TPD

TPE

261/380/759
280/395/790
303/485/969
415/1085
477/520/554/560/672/827/690/805/942/1042/322/343/369/389/412/480/578/618/760/875/1028/925/1049/1043/1229/1144/1325/1500/1642/1035/1170/1325/-

280
378
283
340
362
388
392
-

434/400/816
453/416/847
476/505/1026
512/1193
632/675/709/715
870/1025/845
990
1140/1275/495/516/542/562/585/678/776/816/993/1098/1133/1110/1269/1228/1449/1364/1563/1720/1862/1220/1390/1545/-

454
398
456
503
535
561
565
-

2.3/0.9696/1.800
2.3/0.9696/1.800
2.3/1.524/1.800
1.800/1.800
2.3/2.3/2.3/2.3/3.1/3.1/2.3/3.1/3.1/4.6/2.3/2.3/2.3/2.3/2.3/3.1/3.1/3.1/4.6/4.6/3.1/3.1/4.6/3.1/4.6/4.6/4.6/4.6/4.6/3.1/4.57/4.57/-

2.3
0.9696
2.3
0.9696
2.3
2.3
2.3
2.3
-

The value before the slash applies to the single-head pump and the value after the slash applies to the twin-head pump.

145

23

TP, TPD, TPE

Weights and shipping volume

TP, 2-pole, PN 25
Pump type
TP
TP
TP
TP
TP
TP
TP
TP
TP

100-1000/2
100-1100/2
100-1250/2
100-1350/2
100-1450/2
100-1560/2
100-1700/2
100-2100/2
100-2350/2

DN
DN
DN
DN
DN
DN
DN
DN
DN

Weights
D1 S

100
100
100
100
100
100
100
100
100

DN
DN
DN
DN
DN
DN
DN
DN
DN

125
125
125
125
125
125
125
125
125

Net [kg]

Gross [kg]

Shipping volume
[m3]

675
775
950
1075
1015
1140
1280
1470
1525

850
960
1135
1260
1200
1325
1500
1690
1745

3.13
3.13
3.13
3.13
3.13
3.13
4.57
4.57
4.57

Net [kg]

Gross [kg]

Shipping volume
[m3]

225
241
267
315
380
405
449
515
287
335
360
404
425
469
535
575
705
509
575
615
745
1000
1135
1290
670
800
915
1015
1210
1365
1505
1705
1125
1260
1415
1655
1855
1850
2050

255
271
297
345
413
438
482
670
320
368
393
437
458
624
690
730
860
664
730
770
930
1185
1320
1510
825
985
1100
1200
1430
1585
1725
1925
1310
1445
1635
1875
2165
2160
2360

0.72
0.72
0.72
0.72
0.70
0.70
0.70
2.29
0.70
0.70
0.70
0.70
0.70
2.29
2.29
2.29
2.29
2.29
2.29
2.29
3.13
3.13
3.13
4.57
2.29
3.13
3.13
3.13
4.57
4.57
4.57
4.57
3.13
3.13
4.57
4.57
5.88
5.88
5.88

TP, 4-pole, PN 25
Pump type
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP

146

Connection
D1 D

100-210/4
100-250/4
100-330/4
100-360/4
100-420/4
100-450/4
100-530/4
100-590/4
125-240/4
125-270/4
125-310/4
125-370/4
125-350/4
125-440/4
125-500/4
125-570/4
125-620/4
150-330/4
150-370/4
150-450/4
150-490/4
150-710/4
150-800/4
150-930/4
200-350/4
200-370/4
200-520/4
200-560/4
200-670/4
200-760/4
200-840/4
200-930/4
250-430/4
250-500/4
250-550/4
250-720/4
250-800/4
250-910/4
250-1020/4

Connection
D1 D
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN

100
100
100
100
100
100
100
100
125
125
125
125
125
125
125
125
125
150
150
150
150
150
150
150
200
200
200
200
200
200
200
200
250
250
250
250
250
250
250

Weights
D1 S

DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN

125
125
125
125
125
125
125
125
150
150
150
150
150
150
150
150
150
200
200
200
200
200
200
200
250
250
250
250
250
250
250
250
300
300
300
300
300
300
300

24

TP, TPD, TPE

Minimum efficiency index

24. Minimum efficiency index


Minimum efficiency index (MEI) means the dimensionless scale unit for hydraulic pump efficiency at best efficiency
point (BEP), part load (PL) and overload (OL). The Commission Regulation (EU) sets efficiency requirements to
MEI 0.10 as from 1 January 2013 and MEI 0.40 as from 1 January 2015. An indicative benchmark for
best-performing water pump available on the market as from 1 January 2013 is determined in the Regulation.
The benchmark for most efficient water pumps is MEI 0.70.
The efficiency of a pump with a trimmed impeller is usually lower than that of a pump with the full impeller diameter.
The trimming of the impeller will adapt the pump to a fixed duty point, leading to reduced energy consumption.
The minimum efficiency index (MEI) is based on the full impeller diameter.
The operation of this water pump with variable duty points may be more efficient and economic when controlled, for
example, by the use of a variable-speed drive that matches the pump duty to the system.
Information on benchmark efficiency is available at http://europump.eu/efficiencycharts.

TP, TPD, TPE, 2-pole, PN 6, 10, 16


TP Series 200, 2-pole

P2
[kW]

TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,

0.37
0.55
0.75
1.1
1.5
0.55
0.75
1.1
1.5
2.2
3.0
0.55
1.1
1.5
1.1
1.5
2.2
3.0

TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE

32-80/2
32-160/2
32-220/2
32-260/2
32-330/2
40-80/2
40-160/2
40-240/2
40-270/2
40-330/2
40-390/2
50-80/2
50-160/2
50-240/2
65-80/2
65-160/2
65-240/2
80-160/2

Nominal impeller size/


actual impeller size

32-136/111
32-136/118
32-136/136

TP Series 300, 2-pole

P2
[kW]

Nominal impeller size/


actual impeller size

TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,

2.2
3
4
5.5
7.5
11
4
5.5
7.5
11
15
18.5
2.2
3
4
5.5
15
18.5
22
30
3
4
5.5
7.5
11
15
18.5
37

32-200.1/137
32-200.1/148
32-200.1/160
32-200.1/174
32-200.1/191
32-200.1/205
32-200/150
32-200/163
32-200/176
32-200/200
32-200/210
32-200/219
32-125/113
32-125/123
32-160/137
32-160/146
40-250/184
40-250/204
40-250/213
40-250/232
40-125/110
40-125/120
40-160/133
40-160/145
50-200/157
50-200/170
50-200/180
50-200/219

TPD, TPE 32-300/2


TPD, TPE 32-360/2
TPD, TPE 32-450/2
TPD, TPE 32-550/2
TPD, TPE 32-680/2
TPD, TPE 32-820/2
TPD, TPE 40-370/2
TPD, TPE 40-450/2
TPD, TPE 40-550/2
TPD, TPE 40-740/2
TPD, TPE 40-850/2
TPD, TPE 40-930/2
TPD, TPE 50-250/2
TPD, TPE 50-300/2
TPD, TPE 50-350/2
TPD, TPE 50-410/2
TPD, TPE 50-720/2
TPD, TPE 50-790/2
TPD, TPE 50-880/2
TPD 50-1050/2
TPD, TPE 65-220/2
TPD, TPE 65-260/2
TPD, TPE 65-340/2
TPD, TPE 65-390/2
TPD, TPE 65-480/2
TPD, TPE 65-540/2
TPD, TPE 65-630/2
TPD 65-920/2

Trimmed impeller

Max. impeller

MEI

0.60
0.70

0.40

Trimmed impeller

Max. impeller

0.49
0.70
0.70
0.53
0.43
0.66
0.70
0.56
0.70
0.64
0.70
0.70
0.70

MEI

0.46

0.56

0.70
0.40

0.60

0.18
0.54

0.52

147

24
Minimum efficiency index
148

TP, TPD, TPE

TP Series 300, 2-pole

P2
[kW]

Nominal impeller size/


actual impeller size

TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,

22
30
37
4
5.5
7.5
11
15
18.5
22
30
37
7.5
11
15
18.5
22
30
37
45

50-250/196
50-250/215
50-250/230
50-125/105
50-125/115
50-125/127
65-160/137
65-160/149
65-200/160
65-200/167
65-200/184
65-200/197
65-125/120-110
65-125/130
65-125/141
80-160/147-127
80-160/151-133
80-200/166
80-200/180
80-200/190

TPD, TPE 65-740/2


TPD 65-910/2
TPD 65-1050/2
TPD, TPE 80-200/2
TPD, TPE 80-240/2
TPD, TPE 80-290/2
TPD, TPE 80-330/2
TPD, TPE 80-400/2
TPD, TPE 80-480/2
TPD, TPE 80-530/2
TPD 80-640/2
TPD 80-750/2
TPD, TPE 100-230/2
TPD, TPE 100-300/2
TPD, TPE 100-370/2
TPD, TPE 100-350/2
TPD, TPE 100-380/2
TPD 100-530/2
TPD 100-630/2
TPD 100-700/2

Trimmed impeller

Max. impeller

MEI

0.48

0.53

0.44

0.65

0.60

0.70
0.50

24

TP, TPD, TPE

TP Series 200, 4-pole

P2
[kW]

TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,

0.12
0.25
0.25
0.55
0.25
0.55
0.37
1.1
0.75
1.5
1.1
2.2

TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE

32-40/4
32-80/4
40-40/4
40-80/4
50-40/4
50-80/4
65-40/4
65-80/4
80-40/4
80-80/4
100-40/4
100-80/4

Nominal impeller size/


actual impeller size

Max. impeller

TP Series 300, 4-pole

P2
[kW]

Nominal impeller size/


actual impeller size

TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,

0.55
0.75
1.1
0.75
1.1
1.5
2.2
0.75
1.1
1.5
2.2
3
4
5.5
1.5
2.2
3
4
5.5
7.5
2.2
3
4
5.5
7.5
11
15
18.5
22
3
5.5
4
5.5
11
7.5
11
22
15
18.5
22
30
3.0
4.0
5.5
5.5
7.5
15
18.5
22
30
37

32-200.1/168
32-200.1/180
32-200.1/203
32-200/168
32-200/185
32-200/200
32-200/219
40-200/155
40-200/168
40-200/182
40-250/210
40-250/224
40-250/240
40-250/260
50-200/164
50-200/180
50-200/200
50-250/220
50-250/250
50-250/263
65-160/157
65-200/174
65-200/190
65-250/220
65-250/240
65-315/265
65-315/288
65-315/305
65-315/320
80-160/151
80-160/177
80-200/172
80-200/190
80-200/222
80-250/202
80-250/226
80-250/270
80-315/248
80-315/267
80-315/285
80-315/310
100-160/160-136
100-160/164
100-160/177
100-200/168
100-200/183
100-200/215
100-315/256
100-315/268
100-315/293
100-315/309

TPD, TPE 32-120/4


TPD, TPE 32-140/4
TPD, TPE 32-190/4
TPD, TPE 40-120/4
TPD, TPE 40-160/4
TPD, TPE 40-190/4
TPD, TPE 40-220/4
TPD, TPE 50-110/4
TPD, TPE 50-120/4
TPD, TPE 50-140/4
TPD, TPE 50-190/4
TPD, TPE 50-240/4
TPD, TPE 50-270/4
TPD, TPE 50-340/4
TPD, TPE 65-130/4
TPD, TPE 65-150/4
TPD, TPE 65-190/4
TPD, TPE 65-230/4
TPD, TPE 65-310/4
TPD, TPE 65-330/4
TPD, TPE 80-110/4
TPD, TPE 80-150/4
TPD, TPE 80-170/4
TPD, TPE 80-230/4
TPD, TPE 80-280/4
TPD, TPE 80-340/4
TPD, TPE 80-410/4
TPD, TPE 80-460/4
TPD 80-510/4
TPD, TPE 100-100/4
TPD, TPE 100-150/4
TPD, TPE 100-130/4
TPD, TPE 100-170/4
TPD, TPE 100-260/4
TPD, TPE 100-200/4
TPD, TPE 100-240/4
TPD 100-350/4
TPD, TPE 100-290/4
TPD, TPE 100-340/4
TPD 100-390/4
TPD 100-470/4
TPE 125-100/4
TPE 125-120/4
TPE 125-140/4
TPD, TPE 125-130/4
TPD, TPE 125-160/4
TPD, TPE 125-230/4
TPD, TPE 125-320/4
TPD 125-360/4
TPD 125-430/4
TPD 125-490/4

Trimmed impeller

Trimmed impeller

Max. impeller

Minimum efficiency index

TP, TPD, TPE, 4-pole, PN 6, 10, 16


MEI

0.70
0.70
0.70
0.69
0.70
0.70
0.70
0.70
0.70
0.70
0.45
0.40

MEI

0.70

0.55

0.10

0.44

0.55

0.70

0.51
0.62
0.41

0.70

0.70
0.70

0.63

0.59

0.70

0.67

0.19

149

24

TP, TPD, TPE

Minimum efficiency index

TP Series 300, 4-pole

P2
[kW]

Nominal impeller size/


actual impeller size

TP, TPD, TPE 150-180/4


TP, TPD, TPE 150-210/4
TP, TPD 150-240/4
TP, TPD 150-300/4
TP, TPD 150-340/4
TP, TPD, TPE 150-170/4
TP, TPD, TPE 150-190/4
TP, TPD, TPE 150-230/4
TP, TPD 150-250/4
TP 150-360/4
TP 150-400/4
TP 150-440/4
TP 150-480/4
TP 150-610/4
TP 150-700/4
TP, TPE 200-80/4
TP, TPE 200-110/4
TP, TPE 200-140/4
TP, TPE 200-190/4
TP 200-210/4
TP 200-250/4
TP 200-280/4
TP 200-320/4
TP 200-360/4
TP 200-390/4
TP 200-270/4
TP 200-290/4
TP 200-330/4
TP 200-400/4
TP 200-440/4
TP 200-500/4
TP 200-430/4
TP 200-490/4
TP 200-540/4
TP 200-600/4
TP 200-680/4
TP 200-770/4

15
18.5
22
30
37
11
15
18.5
22
30
37
45
55
75
90
7.5
11
15
18.5
22
30
37
45
55
75
37
45
55
75
90
110
55
75
90
110
132
160

125-250/204
125-250/216
125-250/228
125-250/247
125-250/265
125-200/196-188
125-200/208
125-200/223
125-200/226
125-315/270
125-315/286
125-400/293
125-400/306
125-400/345
125-400/369
150-200/191-121
150-200/200-138
150-200/210-166
150-200/218-206
150-200/224
150-250/232
150-250/245
150-250/262
150-250/273
150-250/286
150-315/242
150-315/255
150-315/267
150-315/290
150-315/305
150-315/322
150-400/299
150-400/322
150-400/337
150-400/355
150-400/374
150-400/394

TP Series 400, 4-pole,


PN10

P2
[kW]

Nominal impeller size/


actual impeller size

TP 250-450/4
TP 250-530/4
TP 250-580/4

90
110
132

250-350/318-308
250-350/337-327
250-350/351-343

TP Series 400, PN 25

P2
[kW]

Nominal impeller size/


actual impeller size

TP Series 400, PN 25

All

Trimmed impeller

Max. impeller

MEI

0.70

0.56

0.70

0.70

0.70

0.70

0.70

0.70

Trimmed impeller

Max. impeller

MEI

0.70

TP, PN 25

** Not in MEI classification because PN 25 is not a part of the MEI classification.

150

Trimmed impeller

Max. impeller

MEI
**

25

TP, TPD, TPE

Accessories

25. Accessories
Counter-flanges
Cast iron pumps
A flange kit consists of two steel flanges, two gaskets of asbestos-free material IT 200, and the requisite number of
bolts.
Counter-flange

Pump type

Description

Rated pressure

Pipework
connection

Product
number

Threaded

10 bar, EN 1092-2

Rp 1 1/4

539703

For welding

10 bar, EN 1092-2

32 mm,
nominal

539704

Threaded

16 bar, EN 1092-2

Rp 1 1/4

539703

For welding

16 bar, EN 1092-2

32 mm,
nominal

539704

Threaded

10 bar, EN 1092-2

Rp 1 1/2

539701

For welding

10 bar, EN 1092-2

40 mm,
nominal

539702

Threaded

16 bar, EN 1092-2

Rp 1 1/2

539701

For welding

16 bar, EN 1092-2

40 mm,
nominal

539702

Threaded

10 bar, EN 1092-2

Rp 2

549801

For welding

10 bar, EN 1092-2

50 mm,
nominal

549802

Threaded

16 bar, EN 1092-2

Rp 2

549801

For welding

16 bar, EN 1092-2

50 mm,
nominal

549802

Threaded

10 bar, EN 1092-2

Rp 2 1/2

559801

For welding

10 bar, EN 1092-2

65 mm,
nominal

559802

Threaded

16 bar, EN 1092-2

Rp 2 1/2

559801

For welding

16 bar, EN 1092-2

65 mm,
nominal

559802

19

Rp 1

Threaded

78
100
140

For welding

TM03 0478 5204

TP, TPE 32
TPD 32

19

Rp 1

Threaded

88
110
150

For welding

TM03 0479 5204

TP, TPE 40
TPD 40

19

Rp 2

Threaded

102
125
165

For welding

TM03 0480 5204

TP, TPE 50
TPD 50

19

Rp 2

Threaded

For welding

122
145
185

TM03 0481 5204

TP, TPE 65
TPD 65

151

25

TP, TPD, TPE

Accessories

Counter-flange

Rp 3

Pump type

Description

Rated pressure

Pipework
connection

Product
number

Threaded

6 bar, EN 1092-2

Rp 3

569902

For welding

6 bar, EN 1092-2

80 mm,
nominal

569901

Threaded

10 bar, EN 1092-2

Rp 3

569802

For welding

10 bar, EN 1092-2

80 mm,
nominal

569801

Threaded

16 bar, EN 1092-2

Rp 3

569802

For welding

16 bar, EN 1092-2

80 mm,
nominal

569801

Threaded

6 bar, EN 1092-2

Rp 4

579901

For welding

6 bar, EN 1092-2

100 mm,
nominal

579902

Threaded

10 bar, EN 1092-2

Rp 4

579801

For welding

10 bar, EN 1092-2

100 mm,
nominal

579802

Threaded

16 bar, EN 1092-2

Rp 4

579801

For welding

16 bar, EN 1092-2

100 mm,
nominal

579802

Threaded

10 bar, EN 1092-2

Rp 5

485367

For welding

10 bar, EN 1092-2

125 mm,
nominal

485368

Threaded

16 bar, EN 1092-2

Rp 5

485367

For welding

16 bar, EN 1092-2

125 mm,
nominal

485368

For welding

10 bar, EN 1092-2

150 mm,
nominal

S1111600

For welding

16 bar, EN 1092-2

150 mm,
nominal

S1111600

19

Threaded

138
160
200

For welding

Rp 4

TM03 0482 5204

TP, TPE 80
TPD 80

19

TP, TPE 100


TPD 100
For welding

TM03 0483 5204

Threaded

158
180
220

Rp 5

19

Threaded

188
210
250

For welding

TM03 0484 5204

TP, TPE 125


TPD 125

For welding

152

212
240
285

TM03 0485 5204

23

TP, TPE 150


TPD 150

25

TP, TPD, TPE

Counter-flange

Pump type

Description

Rated pressure

Pipework
connection

Product
number

Threaded

10 bar, EN 1092-2

Rp 1 1/4

96427029

For welding

10 bar, EN 1092-2

32 mm,
nominal

96427030

Threaded

16 bar, EN 1092-2

Rp 1 1/4

96427029

For welding

16 bar, EN 1092-2

32 mm,
nominal

96427030

Threaded

10 bar, EN 1092-2

Rp 1 1/2

539711

For welding

10 bar, EN 1092-2

40 mm,
nominal

539712

Threaded

16 bar, EN 1092-2

Rp 1 1/2

539711

For welding

16 bar, EN 1092-2

40 mm,
nominal

539712

Threaded

10 bar, EN 1092-2

Rp 2

549811

For welding

10 bar, EN 1092-2

50 mm,
nominal

549812

Threaded

10 bar, EN 1092-2

Rp 2 1/2

559811

For welding

10 bar, EN 1092-2

65 mm,
nominal

559812

Threaded

6 bar, EN 1092-2

Rp 3

96405735

For welding

6 bar, EN 1092-2

80 mm,
nominal

569911

Threaded

10 bar, EN 1092-2

Rp 3

569812

For welding

10 bar, EN 1092-2

80 mm,
nominal

569811

Threaded

6 bar, EN 1092-2

Rp 4

96405737

Threaded

10 bar, EN 1092-2

Rp 4

96405738

19

Rp 1

Accessories

Bronze pumps
A flange kit consists of two bronze flanges, two gaskets of asbestos-free material IT 200, and the requisite number of
bolts.

Threaded

78
100
140

For welding

TM03 0478 5204

TP, TPE 32 B

19

Rp 1

For welding

Threaded

For welding

TP, TPE 50 B

19

Rp 2

Threaded

102
125
165

TM03 0480 5204

19

Rp 2

122
145
185

For welding

Rp 3

TM03 0481 5204

Threaded

88
110
150

TM03 0479 5204

TP, TPE 40 B

TP, TPE 65 B

19

For welding

Rp 4

Threaded

19

For welding

158
180
220

TM03 0485 5204

Threaded

138
160
200

TM03 0482 5204

TP, TPE 80 B

TP, TPE 100 B

153

25

TP, TPD, TPE

TP, TPE Series 300

Note: Base plates are supplied as standard with TP,


TPD, TPE pumps with 11 kW motors and above.

Pump type

TP Series 200
Pump type
TP
TP
TP
TP
TP
TP
TP

32
40
50
65-80/2, 65-160/2, 65-240/2
65-40/4, 65-80/4
80
100

Hexagon head
screws

Product
number

2 x M12 x 20 mm

96405915

2 x M16 x 30 mm

96405914

Drawing

TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,

TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE

Drawing

Product number

380
290
230

2x18
4x14
120
200

4x18

TP, TPE Series 300


Pump type

96536246

TPD Series 300


Product
number

Hexagon head screws

32
40
50
65
80-xx/2
80-110/4
80-150/4
80-170/4
100-230/2
100-300/2
100-370/2

4x14
290

TM00 9835 0497

160

2x14

35

96405915
96405914

2x14
80

96536246

35

2x18

195

2 x M16 x 30 mm

Product number

195

TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE
TPE

Product
number

80-230/4
80-280/4
80-340/4
80-410/4
80-460/4
80-510/4
100-350/2
100-380/2
100-530/2
100-630/2
100-700/2
100-xx/4
125-xx/4
150-xx/4

235

TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,
TP,

Hexagon head screws

TM02 8869 1004

Accessories

Base plates

2 x M16 x 30 mm

00485031

Drawing

Pump type
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD

Hexagon head screws

Product
number

4 x M16 x 30 mm

96489381

32
40
50
65
80-xx/2
80-110/4
80-150/4
80-170/4
100-230/2
100-300/2
100-370/2

Product number
Drawing

235
195

Product number

35

154

300
330

2x14

TM02 5336 2602

4x14
144

96489381

2x18

47

175

67

00485031
2x18

TM00 3755 2602

195
96

35

2x14

25

TP, TPD, TPE

Pump type
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD

Hexagon head screws

Product
number

4 x M16 x 30 mm

96536247

100-350/2
100-380/2
100-530/2
100-630/2
100-700/2
100-100/4
100-130/4
100-150/4
100-170/4

Product number

2x18

355

67

47

230

2x14

385

TM02 8870 1004

35

Drawing

Accessories

TPD Series 300

96536247

TPD Series 300


Pump type

Product
number

4 x M16 x 30 mm

96536248

80-230/4
80-280/4
80-340/4
80-410/4
80-460/4
80-510/4
100-200/4
100-240/4
100-260/4
100-290/4
100-340/4
100-350/4
100-390/4
100-470/4
125-xx/4
150-xx/4

Product number

4x18
47

350
300

475
505

2x14

TM02 8871 1004

35

Drawing

67

TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD

Hexagon head screws

96536248

155

25

TP, TPD, TPE

Normally used with twin-head pumps.

TM00 6360 3495

Accessories

Blanking flanges

TPD 2-pole
Pump type
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD

156

32-300/2
32-360/2
32-450/2
32-550/2
32-680/2
32-820/2
40-370/2
40-450/2
40-550/2
40-740/2
40-850/2
40-930/2
50-250/2
50-300/2
50-350/2
50-410/2
50-720/2
50-790/2
50-880/2
50-1050/2
65-220/2
65-260/2
65-340/2
65-390/2
65-480/2
65-540/2
65-630/2
65-740/2
65-910/2
65-920/2
65-1050/2
80-200/2
80-240/2
80-290/2
80-330/2
80-400/2
80-480/2
80-530/2
80-640/2
80-750/2
100-230/2
100-300/2
100-370/2
100-350/2
100-380/2
100-530/2
100-630/2
100-700/2

96495694

96495695

96495696

96525962

96525963

96525964

25

TP, TPD, TPE

Pump type
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD
TPD

32-120/4
32-140/4
32-190/4
40-120/4
40-160/4
40-190/4
40-220/4
50-110/4
50-120/4
50-140/4
50-190/4
50-240/4
50-270/4
50-340/4
65-130/4
65-150/4
65-190/4
65-230/4
65-310/4
65-330/4
80-110/4
80-150/4
80-170/4
80-230/4
80-280/4
80-340/4
80-410/4
80-460/4
80-510/4
100-100/4
100-130/4
100-150/4
100-170/4
100-200/4
100-240/4
100-260/4
100-290/4
100-340/4
100-350/4
100-390/4
100-470/4
125-210/4
125-230/4
125-260/4
125-320/4
125-360/4
125-430/4
125-490/4
150-180/4
150-210/4
150-240/4
150-300/4
150-340/4

96495694

96495695

96495696

96525962

96525963

Accessories

TPD 4-pole
96525964

157

25

TP, TPD, TPE

Insulating kits are only available for TP Series 200


pumps. An insulating kit consists of two or three
insulating covers made of expanded polypropylene
(EPP).
The insulating kit is tailored to the individual pump
model and has an insulating thickness corresponding
to the nominal diameter of the pump.
The thermal conductivity of EPP is very low (0.04 W/m
C), i.e. the insulating property is very good.
The insulating kit encloses the entire pump housing.

TM00 8095 2496

Accessories

Insulating kits

Fig. 74 Insulating kit

Product numbers of insulating kits


Single-head TP Series 200 pumps
Pump type
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP

158

32-40/4
32-80/2
32-80/4
32-160/2
32-220/2
32-260/2
32-330/2
40-40/4
40-80/2
40-80/4
40-160/2
40-240/2
40-270/2
40-330/2
40-390/2
50-40/4
50-80/2
50-80/4
50-160/2
50-240/2
65-40/4
65-80/2
65-80/4
65-160/2
65-240/2
80-40/4
80-80/4
80-160/2
100-40/4
100-80/4

Product number
96405880
96405873
96405880
96405880
96472051
96472051
96472051
96405874
96405876
96405875
96405877
96405878
96472052
96472052
96472052
96405879
96405881
96405880
96405882
96405883
96405884
96405886
96405885
96405887
96405888
96405889
96405890
96405891
96405892
96405892

25

TP, TPD, TPE

Accessories

Sensors
Flow sensors
Grundfos vortex flow
sensor, VFI 1)

VFI
VFI
VFI
VFI
VFI
VFI
VFI
VFI
VFI
VFI
VFI
VFI
VFI
Housing material:
VFI
Stainless steel (1.4408)
VFI
Sensor material:
Stainless steel (1.4404) VFI
Flange material:
VFI
Cast iron
VFI
4-20 mA output signal
VFI
5 m cable with M12
connection in one end. VFI
VFI
VFI
VFI
VFI
1)

Flow range
[m3/h]

Type
1.3-25 DN32 020 E
1.3-25 DN32 020 F
1.3-25 DN32 020 E
1.3-25 DN32 020 F
2-40 DN40 020 E
2-40 DN40 020 F
2-40 DN40 020 E
2-40 DN40 020 F
3.2-64 DN50 020 E
3.2-64 DN50 020 F
3.2-64 DN50 020 E
3.2-64 DN50 020 F
5.2-104 DN65 020 E
5.2-104 DN65 020 F
5.2-104 DN65 020 E
5.2-104 DN65 020 F
8-160 DN80 020 E
8-160 DN80 020 F
8-160 DN80 020 E
8-160 DN80 020 F
12-240 DN100 020 E
12-240 DN100 020 F
12-240 DN100 020 E
12-240 DN100 020 F

O-ring
Pipe
connection EPDM FKM

Connection type
Cast iron
flange

1.3 - 25

DN 32

Stainless steel
flange

2 - 40

DN 40

2 - 64

DN 50

5.2 - 104

DN 65

8 - 160

DN 80

12 - 240

DN 100

97686141
97686142
97688297
97688298
97686143
97686144
97688299
97688300
97686145
97686146
97688301
97688302
97686147
97686148
97688303
97688304
97686149
97686150
97688305
97688306
97686151
97686152
97688308
97688309

Product number

For more information about the VFI sensor, see the data booklet "Grundfos direct sensors", publication number 97790189.

Temperature sensors
Accessory
Temperature
Temperature
Temperature
Temperature

Type
sensor
sensor
sensor
sensor

Accessory for temperature sensor.


All with 1/2 RG connection.
Temperature sensor,
ambient temperature
Differential temperature sensor
Differential temperature sensor

TTA (0) 25
TTA (-25) 25
TTA (50) 100
TTA (0) 150
Protecting tube
9 x 50 mm
Protecting tube
9 x 100 mm
Cutting ring bush
WR 52
ETSD
ETSD

Supplier
Carlo
Carlo
Carlo
Carlo

Measuring range

Product number

0-25 C
-25 - +25 C
50-100 C
0-150 C

96432591
96430194
96432592
96430195

Gavazzi
Gavazzi
Gavazzi
Gavazzi

Carlo Gavazzi

96430201

Carlo Gavazzi

96430202

Carlo Gavazzi
tmg
(DK: Plesner)
Honsberg
Honsberg

96430203
-50 - +50 C

ID8295

0-20 C
0-50 C

96409362
96409363

Note: All sensors have 4-20 mA output signal.

Sensors for boosting applications


Danfoss pressure sensor kit

Connection: G 1/2 A (DIN 16288 - B6kt)


Electrical connection: plug (DIN 43650)

Pressure sensor type MBS 3000, with 2 m screened cable


Connection: G 1/4 A (DIN 16288 - B6kt)
5 cable clips (black)
Fitting instructions PT (00400212)

Pressure range

Product number

0 - 2.5 bar
0 - 4 bar
0 - 6 bar
0 - 10 bar
0 - 16 bar
0 - 2.5 bar
0 - 4 bar
0 - 6 bar
0 - 10 bar
0 - 16 bar

96478188
91072075
91072076
91072077
91072078
405159
405160
405161
405162
405163

159

25

TP, TPD, TPE

Accessories

Sensors for circulation applications


Grundfos differential pressure sensor, DPI

1 sensor incl. 0.9 m screened cable (7/16" connections)


1 original DPI bracket (for wall mounting)
1 Grundfos bracket (for mounting on motor)
2 M4 screws for mounting of sensor on bracket
1 M6 screw (self-cutting) for mounting on MGE 90/100
1 M8 screw (self-cutting) for mounting on MGE 112/132
1 M10 screw (self-cutting) for mounting on MGE 160
1 M12 screw (self-cutting) for mounting on MGE 180
3 capillary tubes (short/long)
2 fittings (1/4" - 7/16")
5 cable clips (black)
Installation and operating instructions
Service kit instruction

Pressure range

Product number

0 - 0.6 bar

96611522

0 - 1.0 bar

96611523

0 - 1.6 bar

96611524

0 - 2.5 bar

96611525

0 - 4.0 bar

96611526

0 - 6.0 bar

96611527

0 - 10 bar

96611550

Select the differential pressure sensor so that the maximum pressure of the sensor is higher than the maximum differential pressure of the pump.

Sensor interface
Sensor interface, SI 001 PSU 1)

Description

Grundfos Direct Sensors, type SI 001 PSU, is an external power supply for the VFI, DPI
and other transmitters with 24 VDC supply voltage.
It is used when the cable between transmitter and controller is more than 30 metres long.

1)

160

Product number

96915820

For more information about the PSU sensor interface, see the installation and operating instructions "SI 001 PSU - sensor interface", publication
number 96944355, or quick guide, publication number 96944356.

25

TP, TPD, TPE

Accessories

MP 204 - advanced motor protection


The MP 204 is an electronic motor protection for pumps. One unit covers all electrical motors from 3 to 999 A as well
as voltages from 100 to 480 VAC.
Installation of the MP 204 is by means of screws onto a wall or back plate, or on a mounting rail.
Component

Functions

The MP 204 is an electronic motor protector and


data collecting unit. Apart from protecting the
motor, it can also send information to a CIU unit
via GENIbus, such as:
trip
warning
energy consumption
input power
motor temperature.
The MP 204 protects the motor primarily by
measuring the motor current by means of a true
RMS measurement.
The pump is protected secondarily by measuring
the temperature with a Tempcon sensor, a
Pt100/Pt1000 sensor and a PTC sensor/thermal
switch.
The MP 204 is designed for single- and
three-phase motors.

Features
Phase-sequence monitoring
indication of current or temperature
input for PTC sensor/thermal switch
indication of temperature in C or F
4-digit, 7-segment display
setting and status reading with the Grundfos R100 remote
control
setting and status reading via the Grundfos GENIbus
fieldbus.
Tripping conditions
Overload
underload (dry running)
temperature
missing phase
phase sequence
overvoltage
undervoltage
power factor (cos )
current unbalance.
Warnings
Overload
underload
temperature
overvoltage
undervoltage
power factor (cos )
run capacitor (single-phase operation)
starting capacitor (single-phase operation)
loss of communication in network
harmonic distortion.
Learning function
Phase sequence (three-phase operation)
run capacitor (single-phase operation)
starting capacitor (single-phase operation)
identification and measurement of Pt100/Pt1000 sensor
circuit.

TM03 0150 4204

MP 204

Description

Control MP 204
The Control MP 204 is supplied as a plug-and-play control cabinet solution.
The main switch and LED panel showing power consumption are all you see on the front. Inside you find the MP 204
unit and optional communication interface units.
Cabinet type

Description

Functions

The Control MP 204 control cabinets are


supplied with all necessary components.
Three types of control cabinets are available,
depending on functions and starting method.
The control cabinets are designed for
installation in a control cabinet for outdoor use.
The Control MP 204 control cabinets have a
built-in main switch and a thermal magnetic
circuit breaker.

Digital input
Float switch or pressure relay (if no IO 112 is used).
Analog input
Too high motor temperature (Tempcon)
thermistor/PTC, pump
pressure sensor, 4-20 mA (with IO 112).
Relay output
Pump alarm.
Communication
Grundfos Remote Management.
GSM/GPRS
(IO 112 not supported)
Modbus RTU wired
(IO 112 not supported)
PROFIBUS DP
(IO 112 not supported).
Protection
Protects the pump against short-circuit.

TM04 9512 4410

Control MP 204

For more information about the MP 204 and Control MP 204, see the data booklet "Control MP 204", publication
number 97770915.

161

25

TP, TPD, TPE

MI 202 and MI 204


The MI 202 and MI 204 are add-on modules with
built-in infrared and radio communication. The MI 202
can be used in conjunction with Apple iPod Touch 4,
iPhone 4 and 4S.
The MI 204 can be used in conjunction with Apple iPod
Touch 5G, iPhone 5 or later.

Fig. 75 Potentiometer

MI 202

Potentiometer for setpoint setting and start/stop of the


pump.
Product

Product number

External potentiometer with cabinet for wall


mounting.

625468

Grundfos GO Remote

Fig. 77 MI 202 and MI 204

The Grundfos GO Remote is used for wireless infrared


or radio communication with the pumps.
Various Grundfos GO Remote variants are available.
The variants are described in the following.
MI 201

Supplied with the product:


Grundfos MI 202 or 204
sleeve
quick guide
charger cable.
MI 301
The MI 301 is a module with built-in infrared and radio
communication. The MI 301 must be used in
conjunction with an Android or iOS-based smartphone
with a Bluetooth connection. The MI 301 has
rechargeable Li-ion battery and must be charged
separately.

TM05 3890 1712

TM05 3886 1712

The MI 201 is a complete solution, consisting of an


Apple iPod touch 4G and a Grundfos cover for infrared
and radio communication with Grundfos pumps or
systems.

Fig. 76 MI 201

Supplied with the product:


Apple iPod touch 4G incl. accessories
Grundfos MI 201 cover
battery charger
quick guide.

162

MI 204

TM05 3887 1612 - TM05 7704 1513

TM02 1630 5102

Accessories

Potentiometer

Fig. 78 MI 301

Supplied with the product:


Grundfos MI 301
sleeve
battery charger
quick guide.

25

TP, TPD, TPE

Grundfos GO Remote variant


Grundfos
Grundfos
Grundfos
Grundfos

MI
MI
MI
MI

Accessories

CIU communication interface units

Product numbers
Product number

201
202
204
301

98140638
98046376
98424092
98046408

HTC

Desire S
Sensation
Galaxy S II

Samsung
LG

Galaxy Nexus
Google Nexus 4

iOS 6.0 or later

Android 2.3.3 or
later

Android 2.3.4 or
later

Android 4.0 or
later
Android 4.2 or
later

Note: Similar Android and iOS-based devices may


work as well, but are not supported by Grundfos.

GrA 6118

iOS 5.0 or later

MI 301

Apple

iPod touch 4G
iPhone 4, 4S
iPod touch 5G
iPhone 5

Operating
system

MI 204

Model

MI 202

Make

MI 201

Supported units

Fig. 79 Grundfos CIU communication interface unit

The CIU units enable communication of operating


data, such as measured values and setpoints, between
TPE pumps and a building management system.
The CIU unit incorporates a 24-240 VAC/VDC power
supply module and a CIM module. It can either be
mounted on a DIN rail or on a wall.
We offer the following CIU units:
CIU 100
For communication via LON.
CIU 150
For communication via PROFIBUS DP.
CIU 200
For communication via Modbus RTU.
CIU 250
For communication via GSM/GPRS.
CIU 271
For communication via Grundfos Remote Management
(GRM).
CIU 300
For communication via BACnet MS/TP.
Description

Fieldbus protocol

Product number

CIU
CIU
CIU
CIU
CIU
CIU

LON
PROFIBUS DP
Modbus RTU
GSM/GPRS
GRM
BACnet MS/TP

96753735
96753081
96753082
96787106
96898819
Contact Grundfos

100
150
200
250*
271*
300

* Antenna not included. See below.

Antennas for CIU 250 and 270


Description

Product number

Antenna for roof


Antenna for desk

97631956
97631957

For further information about data communication via


CIU units and fieldbus protocols, see the CIU
documentation available in WebCAPS.

163

25

TP, TPD, TPE

Accessories

CIM communication interface


modules

Antennas for CIM 250 and 270


Description

Product number

Antenna for roof


Antenna for desk

97631956
97631957

For further information about data communication via


CIM modules and fieldbus protocols, see the CIM
documentation available in WebCAPS.

EMC filter
GrA 6121

EMC (electromagnetic compatibility to EN 61800-3)

Fig. 80 Grundfos CIM communication interface module

The CIM modules enable communication of operating


data, such as measured values and setpoints, between
11-22 kW TPE pumps and a building management
system. The CIM modules are add-on communication
modules which are installed in the terminal box of
11-22 kW TPE pumps.
Note: CIM modules must be installed by authorised
personnel.
We offer the following CIM modules:
CIM 100
For communication via LON.
CIM 150

Motor [kW]
2-pole

4-pole

0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
15
18.5
22

0.37
0.55
0.75
1.1
1.5
2.2
3.0
4.0
5.5
7.5
11
15
18.5
-

For communication via PROFIBUS DP.

Emission/immunity

Emission:
Motors may be installed in residential areas
(first environment), unrestricted distribution,
corresponding to CISPR11, group 1, class B.
Immunity:
Motors fulfil the requirements for both the first
and second environment.

Emission:
The motors are category C3, corresponding to
CISPR11, group 2, class A, and may be
installed in industrial areas (second
environment).
If equipped with an external Grundfos EMC
filter, the motors are category C2,
corresponding to CISPR11, group 1, class A,
and may be installed in residential areas (first
environment).

CIM 200
For communication via Modbus RTU.
TM02 9198 1203

CIM 250
For wireless communication via GSM/GPRS.
CIM 271
For communication via Grundfos Remote Management
(GRM).
CIM 300
For communication via BACnet MS/TP.
Description

Fieldbus protocol

Product number

CIM 100
CIM 150
CIM 200
CIM 250*
CIU 271*
CIM 300

LON
PROFIBUS DP
Modbus RTU
GSM/GPRS
GRM
BACnet MS/TP

96824797
96824793
96824796
96824795
96898815
Contact Grundfos

164

Antenna not included. See below.

Fig. 81 EMC filter

The EMC filter for residential areas is available as a


complete kit ready for installation.
Product
EMC filter (TPE 5.5 kW and 7.5 kW, 4-pole)
EMC filter (TPE 11-22 kW)

Product number
96041047
96478309

26

TP, TPD, TPE

Minimum inlet pressure - NPSH

26. Minimum inlet pressure - NPSH


To ensure optimum and noiseless operation we
recommend the minimum inlet pressure values shown
on pages 166 to 168.
A minimum inlet pressure is required to avoid pressure
drops that may cause cavitation.
The minimum inlet pressure (ps) in bar relative
(pressure gauge value on the pump suction side) can
be calculated using the following formula.
Note: Calculation of the minimum inlet pressure
should be based on the maximum required flow.
2
1
p ( NPSH + H ) g --- c 0.00001 p + p
2

S
R
S
b
d

Temp.
[C]

Ps

NPSH

Pd
[bar]

150

4.76

140

3.61

130

2.70

120

1.99

110

1.43

100

1.01

90

0.70

80

0.47

70

0.31

60

0.20

50

0.12

40

0.07

30

0.04

20

0.02

10

0.01

TM02 8491 0204 - TM03 0371 5004

ps
= Minimum inlet pressure in bar.
NPSHR = The required Net Positive Suction Head
in metres head.
(To be read from the NPSH curve at the
highest flow the pump will be delivering).
Hs
= Safety margin = minimum 0.5 metres
head.
Note: A safety margin of 0.5 metres
prevents pressure drop.
r
= Density of the pumped liquid measured in
kg/m3.
g
= Gravitational acceleration measured in
m/s. For estimated calculations, use the
value 9.81 m/s2.
c
= Flow velocity of the pumped liquid at the
pressure gauge. Insert the flow velocity
as the unit [m/s].
(See individual curve charts from page
80).
= Barometric pressure in bar.
pb
(Set the barometric pressure to 0.97 bar).
Note: Only occasionally is the pressure
as high as 1 bar. Furthermore, this value
is at sea level.
pd
= Vapour pressure in bar.
(See fig. 82).

[bar relative]

Fig. 82 Minimum inlet pressure

165

26
Minimum inlet pressure - NPSH
166

TP, TPD, TPE

TP, TPD 2-pole, PN 6, 10, 16


Pump type

p [bar]

Pump type

20 C 60 C 90 C 110 C 120 C 140 C

p [bar]
20 C 60 C 90 C 110 C 120 C 140 C

TP 32-80/2

0.4

0.4

0.4

1.2

1.7

3.4

TP 80-160/2

2.1

2.3

2.8

3.6

4.1

5.8

TP 32-160/2

0.4

0.6

1.1

1.9

2.4

4.1

TP, TPD 80-200/2

0.5

0.7

1.2

1.9

2.5

4.1

TP 32-220/2

0.7

0.9

1.4

2.2

2.7

4.4

TP, TPD 80-240/2

0.1

0.2

0.7

1.4

2.0

3.6

TP 32-260/2

0.7

0.9

1.4

2.2

2.7

4.4

TP, TPD 80-290/2

0.1

0.3

0.8

1.5

2.1

3.7

0.2

0.4

0.9

1.7

2.2

3.8

TP 32-330/2

0.7

0.9

1.4

2.2

2.7

4.4

TP, TPD 80-330/2

TP, TPD 32-300/2

0.1

0.1

0.1

0.7

1.2

2.8

TP, TPD 80-400/2

0.6

0.8

1.3

2.1

2.6

4.2

TP, TPD 32-360/2

0.1

0.1

0.1

0.7

1.2

2.8

TP, TPD 80-480/2

0.1

0.3

0.8

1.5

2.1

3.7

TP, TPD 32-450/2

0.1

0.1

0.1

0.7

1.2

2.8

TP, TPD 80-530/2

0.2

0.4

0.9

1.6

2.1

3.8

0.6

0.8

1.3

2.0

2.6

4.2

TP, TPD 32-550/2

0.1

0.1

0.1

0.7

1.2

2.9

TP, TPD 80-640/2

TP, TPD 32-680/2

0.1

0.1

0.1

0.8

1.4

3.1

TP, TPD 80-750/2

0.6

0.8

1.3

2.0

2.6

4.2

TP, TPD 32-820/2

0.5

0.7

1.2

1.9

2.5

4.1

TP, TPD 100-230/2

0.4

0.6

1.1

1.9

2.4

4.0

TP 40-80/2

0.1

0.3

0.8

1.6

2.1

3.8

TP, TPD 100-300/2

0.2

0.4

0.9

1.6

2.2

3.8

0.3

0.5

1.0

1.7

2.3

3.9

TP 40-160/2

0.1

0.2

0.7

1.5

2.0

3.7

TP, TPD 100-370/2

TP 40-240/2

0.4

0.6

1.1

1.9

2.4

4.1

TP, TPD 100-350/2

0.9

1.1

1.6

2.3

2.9

4.5

TP 40-270/2

0.7

0.9

1.4

2.2

2.7

4.4

TP, TPD 100-380/2

1.2

1.4

1.9

2.6

3.2

4.8

TP 40-330/2

0.7

0.9

1.4

2.2

2.7

4.4

TP, TPD 100-530/2

1.7

1.9

2.4

3.2

3.7

5.3

1.4

1.6

2.1

2.8

3.3

5.0

3.0

3.2

3.7

4.4

5.0

6.6

TP 40-390/2

0.7

0.9

1.4

2.2

2.7

4.4

TP, TPD 100-630/2

TP, TPD 40-370/2

0.1

0.1

0.1

0.8

1.3

2.9

TP, TPD 100-700/2

TP, TPD 40-450/2

0.1

0.1

0.1

0.8

1.4

3.0

TP, TPD 40-550/2

0.1

0.1

0.1

0.8

1.4

3.0

TP, TPD 40-740/2

0.1

0.1

0.3

1.0

1.6

3.2

TP, TPD 40-850/2

0.1

0.1

0.6

1.3

1.9

3.5

TP, TPD 40-930/2

0.3

0.5

1.0

1.7

2.3

3.9

TP 50-80/2

0.1

0.1

0.6

1.4

1.9

3.6

TP 50-160/2

0.4

0.6

1.1

1.9

2.4

4.1

TP 50-240/2

0.3

0.5

1.0

1.8

2.3

4.0

TP, TPD 50-250/2

0.1

0.1

0.2

1.0

1.5

3.1

TP, TPD 50-300/2

0.1

0.1

0.3

1.0

1.6

3.2

TP, TPD 50-350/2

0.1

0.1

0.3

1.0

1.6

3.2

TP, TPD 50-410/2

0.1

0.1

0.4

1.1

1.6

3.3

TP, TPD 50-440/2

0.1

0.1

0.5

1.2

1.8

3.4

TP, TPD 50-540/2

0.1

0.2

0.7

1.4

2.0

3.6

TP, TPD 50-720/2

0.1

0.3

0.8

1.6

2.1

3.7

TP, TPD 50-790/2

0.5

0.7

1.2

1.9

2.5

4.1

TP, TPD 50-880/2

0.8

1.0

1.5

2.2

2.8

4.4

TP 50-1050/2

1.1

1.3

1.8

2.5

3.1

4.7

TP 65-80/2

0.6

0.8

1.3

2.1

2.6

4.3

TP 65-160/2

1.1

1.3

1.8

2.6

3.1

4.8

TP 65-240/2

0.9

1.1

1.6

2.4

2.9

4.6

TP, TPD 65-220/2

0.1

0.1

0.2

0.9

1.4

3.1

TP, TPD 65-260/2

0.1

0.1

0.2

0.9

1.5

3.1

TP, TPD 65-340/2

0.1

0.1

0.2

1.0

1.5

3.1

TP, TPD 65-390/2

0.1

0.1

0.3

1.0

1.5

3.2

TP, TPD 65-480/2

0.1

0.1

0.3

1.0

1.6

3.2

TP, TPD 65-540/2

0.1

0.1

0.3

1.1

1.6

3.2

TP, TPD 65-630/2

0.1

0.1

0.4

1.1

1.7

3.3

TP, TPD 65-740/2

0.1

0.1

0.6

1.3

1.9

3.5

TP, TPD 65-910/2

0.1

0.2

0.7

1.5

2.0

3.6

TP, TPD 65-920/2

0.1

0.2

0.7

1.4

2.0

3.6

TP, TPD 65-1050/2

0.1

0.2

0.7

1.5

2.0

3.6

26

TP, TPD, TPE

Pump type
TP 32-40/4
TP 32-80/4
TP, TPD 32-120/4
TP, TPD 32-140/4
TP, TPD 32-190/4
TP 40-40/4
TP 40-80/4
TP, TPD 40-120/4
TP, TPD 40-160/4
TP, TPD 40-190/4
TP, TPD 40-220/4
TP 50-40/4
TP 50-80/4
TP, TPD 50-110/4
TP, TPD 50-120/4
TP, TPD 50-140/4
TP, TPD 50-190/4
TP, TPD 50-240/4
TP, TPD 50-270/4
TP, TPD 50-340/4
TP 65-40/4
TP 65-80/4
TP, TPD 65-130/4
TP, TPD 65-150/4
TP, TPD 65-190/4
TP, TPD 65-230/4
TP, TPD 65-310/4
TP, TPD 65-330/4
TP 80-40/4
TP 80-80/4
TP, TPD 80-110/4
TP, TPD 80-150/4
TP, TPD 80-170/4
TP, TPD 80-230/4
TP, TPD 80-280/4
TP, TPD 80-340/4
TP, TPD 80-410/4
TP, TPD 80-460/4
TP, TPD 80-510/4
TP 100-40/4
TP, TPD 100-100/4
TP, TPD 100-130/4
TP, TPD 100-150/4
TP, TPD 100-170/4
TP, TPD 100-200/4
TP, TPD 100-240/4
TP, TPD 100-260/4
TP, TPD 100-290/4
TP, TPD 100-340/4
TP, TPD 100-350/4
TP, TPD 100-390/4
TP, TPD 100-470/4
TP 125-100/4
TP 125-120/4
TP 125-140/4
TP, TPD 125-130/4
TP, TPD 125-160/4
TP, TPD 125-210/4
TP, TPD 125-230/4
TP, TPD 125-260/4
TP, TPD 125-320/4
TP, TPD 125-360/4
TP, TPD 125-430/4
TP, TPD 125-490/4
TP 150-170/4
TP, TPD 150-180/4
TP 150-190/4

p [bar]

Pump type

20 C 60 C 90 C 110 C 120 C 140 C


0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.4
0.7
0.1
0.1
0.1
0.1
0.1
0.1
1.5
1.6
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
1.4
0.1
0.1
0.1
0.1
0.1
0.1
0.6
0.5
0.6
0.2
0.7
0.9
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.4
0.1
0.1

0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.6
0.9
0.1
0.1
0.1
0.1
0.1
0.1
1.7
1.8
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
1.6
0.1
0.1
0.1
0.1
0.1
0.1
0.8
0.7
0.8
0.4
0.9
1.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.3
0.6
0.2
0.2

0.1
0.5
0.1
0.1
0.1
0.3
0.2
0.1
0.1
0.1
0.2
0.3
0.3
0.1
0.1
0.1
0.1
0.2
0.3
0.7
1.1
1.4
0.1
0.1
0.1
0.1
0.1
0.1
2.2
2.3
0.1
0.1
0.1
0.3
0.2
0.3
0.5
0.6
0.7
2.1
0.2
0.3
0.6
0.6
0.4
0.6
1.3
1.2
1.3
0.9
1.4
1.6
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.4
0.5
0.8
1.1
0.7
0.7

0.9
1.3
0.7
0.7
0.8
1.1
1.0
0.5
0.6
0.7
0.9
1.1
1.1
0.6
0.7
0.7
0.8
0.9
1.0
1.4
1.9
2.2
0.6
0.6
0.6
0.7
0.7
0.3
3.0
3.1
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.3
1.5
2.9
0.9
1.0
1.3
1.3
1.1
1.3
2.1
2.0
2.0
1.7
2.1
2.3
1.0
1.0
1.0
1.0
1.1
1.0
1.1
1.2
1.1
1.1
1.3
1.5
1.8
1.4
1.4

1.4
1.8
1.3
1.3
1.4
1.6
1.5
1.1
1.2
1.2
1.4
1.6
1.6
1.2
1.2
1.3
1.4
1.5
1.6
2.0
2.4
2.7
1.2
1.2
1.2
1.3
1.3
0.8
3.5
3.6
1.4
1.3
1.3
1.6
1.5
1.6
1.8
1.9
2.0
3.4
1.5
1.6
1.9
1.9
1.7
1.9
2.7
2.5
2.6
2.3
2.7
2.9
1.6
1.6
1.6
1.6
1.6
1.6
1.7
1.7
1.6
1.7
1.8
2.1
2.4
1.9
2.0

3.1
3.5
2.9
2.9
3.0
3.3
3.2
2.7
2.8
2.8
3.1
3.3
3.3
2.8
2.8
2.9
3.0
3.1
3.2
3.6
4.1
4.4
2.8
2.8
2.8
2.9
2.9
2.5
5.2
5.3
3.0
2.9
3.0
3.2
3.1
3.2
3.4
3.5
3.6
5.1
3.1
3.2
3.5
3.5
3.3
3.5
4.3
4.1
4.2
3.9
4.3
4.5
3.2
3.2
3.2
3.2
3.2
3.2
3.3
3.3
3.2
3.3
3.4
3.7
4.0
3.6
3.6

TP, TPD 150-210/4


TP 150-230/4
TP, TPD 150-240/4
TP 150-250/4
TP, TPD 150-300/4
TP, TPD 150-340/4
TP 150-360/4
TP 150-400/4
TP 150-440/4
TP 150-480/4
TP 150-610/4
TP 150-700/4
TP 200-80/4
TP 200-110/4
TP 200-140/4
TP 200-190/4
TP 200-210/4
TP 200-250/4
TP 200-280/4
TP 200-320/4
TP 200-360/4
TP 200-390/4
TP 200-400/4
TP 200-430/4
TP 200-440/4
TP 200-490/4
TP 200-500/4
TP 200-540/4
TP 200-600/4
TP 200-680/4
TP 200-770/4
TP 250-450/4
TP 250-530/4
TP 250-580/4

Minimum inlet pressure - NPSH

TP, TPD 4-pole, PN 6, 10, 16


p [bar]
20 C 60 C 90 C 110 C 120 C 140 C
0.1
0.1
0.1
0.1
0.1
0.1
0.3
0.1
0.1
0.1
0.1
0.1
0.9
0.5
0.3
0.2
0.1
0.9
0.7
0.6
0.4
0.3
0.1
0.1
0.1
0.1
0.2
0.1
0.1
0.1
0.1
1.5
1.5
1.4

0.2
0.1
0.2
0.1
0.3
0.3
0.5
0.1
0.1
0.1
0.2
0.3
1.1
0.6
0.5
0.4
0.2
1.0
0.9
0.8
0.6
0.5
0.1
0.1
0.2
0.1
0.4
0.1
0.1
0.1
0.2
1.7
1.7
1.6

0.7
0.6
0.7
0.5
0.8
0.8
1.0
0.1
0.4
0.5
0.7
0.8
1.6
1.1
1.0
0.9
0.7
1.5
1.4
1.3
1.1
1.0
0.6
0.6
0.7
0.1
0.9
0.1
0.1
0.1
0.7
2.2
2.2
2.1

1.4
1.3
1.5
1.2
1.5
1.5
1.8
0.8
1.1
1.3
1.4
1.5
2.3
1.9
1.7
1.6
1.4
2.3
2.1
2.0
1.8
1.7
1.3
1.4
1.5
0.8
1.6
0.8
0.8
0.8
1.4
2.9
2.9
2.9

2.0
1.9
2.0
1.8
2.1
2.1
2.3
1.4
1.7
1.8
2.0
2.1
2.9
2.4
2.3
2.2
2.0
2.8
2.7
2.6
2.4
2.2
1.9
1.9
2.0
1.4
2.2
1.4
1.4
1.4
2.0
3.5
3.5
3.4

3.6
3.5
3.6
3.4
3.7
3.7
4.0
3.1
3.3
3.4
3.6
3.7
4.5
4.0
3.9
3.8
3.6
4.4
4.3
4.2
4.0
3.9
3.6
3.6
3.7
3.1
3.9
3.1
3.1
3.1
3.7
5.2
5.2
5.1

167

26

TP, TPD, TPE

Minimum inlet pressure - NPSH

TP Series 400, 2-pole, PN 25


Pump type

p [bar]
20 C

60 C

90 C

110 C 120 C 140 C

TP 100-1000/2

0.5

0.7

1.2

1.9

2.5

4.2

TP 100-1100/2

0.4

0.6

1.1

1.9

2.4

4.1

TP 100-1250/2

0.4

0.6

1.1

1.8

2.4

4.1

TP 100-1350/2

0.3

0.5

1.0

1.8

2.3

4.0

TP 100-1450/2

0.6

0.8

1.3

2.1

2.6

4.3

TP 100-1560/2

0.6

0.8

1.3

2.0

2.6

4.3

TP 100-1700/2

0.5

0.7

1.2

2.0

2.5

4.2

TP 100-2100/2

0.5

0.7

1.2

1.9

2.5

4.2

TP 100-2350/2

0.4

0.6

1.1

1.8

2.4

4.1

TP Series 400, 4-pole, PN 25


Pump type
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP

168

100-210/4
100-250/4
100-330/4
100-360/4
100-420/4
100-450/4
100-530/4
100-590/4
125-240/4
125-270/4
125-310/4
125-370/4
125-350/4
125-440/4
125-500/4
125-570/4
125-620/4
150-330/4
150-370/4
150-450/4
150-490/4
150-710/4
150-800/4
150-930/4
200-220/4
200-250/4
200-310/4
200-350/4
200-370/4
200-520/4
200-560/4
200-670/4
200-760/4
200-840/4
200-930/4
250-430/4
250-500/4
250-550/4
250-720/4
250-800/4
250-910/4
250-1020/4

p [bar]
20 C

60 C

90 C

0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
0.3
0.2
0.2
0.4
0.4
0.4
0.4

0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.2
0.2
0.2
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.4
0.4
0.4
0.4
0.5
0.4
0.4
0.6
0.6
0.6
0.6

0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.7
0.7
0.7
0.7
0.6
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.6
0.9
0.9
0.9
0.9
1.0
0.9
0.9
1.1
1.1
1.1
1.1

110 C 120 C 140 C


0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.5
1.5
1.4
1.4
1.4
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
1.3
1.7
1.6
1.6
1.6
1.7
1.7
1.7
1.8
1.8
1.8
1.8

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
2.0
2.0
2.0
2.0
1.9
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.9
2.2
2.2
2.2
2.2
2.3
2.2
2.2
2.4
2.4
2.4
2.4

3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.7
3.7
3.7
3.7
3.6
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.1
3.6
3.9
3.9
3.9
3.9
4.0
3.9
3.9
4.1
4.1
4.1
4.1

27

TP, TPD, TPE

Key application data

27. Key application data


Dear customer, if an ATEX certificate is needed or if pump selection cannot be made on the basis of the guidelines in
Pumped liquids, please fill in the following form in cooperation with a Grundfos representative. This will help to ensure
that Grundfos supplies you with a pump solution adapted to meet exactly your needs in terms of pump type, pump
materials, shaft seal type, elastomers and accessories.
This form is also available under "Literature" in WebCAPS and WinCAPS.
Customer information
Company name:
Customer number:
Phone number:
Fax number:
E-mail address:

Project title:
Reference number:
Customer contact:

Quotation made by:


Company name:
Phone number:
Fax number:
E-mail address:

Prepared by:
Date:

Page 1 of

Quotation number:

Operating conditions
Pumped liquid
Type of liquid:
Chemical composition (if available):
Distilled/demineralised water?
Conductivity of distilled/demineralised water:
Minimum liquid temperature:
Maximum liquid temperature:
Vapour pressure of liquid:
Liquid concentration:
Liquid pH value:
Dynamic liquid viscosity:
Kinematic liquid viscosity:
Liquid density:
Specific heat capacity of liquid:
Air/gas in liquid?
Solids in liquid?
Contents of solids in liquid (if available):
Additives in liquid?
Does the liquid crystallise?
When does crystallisation happen?

Yes:

No:
[S/cm]
[C]
[C]
[bar]
%

Yes:
Yes:
Yes:
Yes:

[cP] = [mPa s]
[cSt] = [mm2/s]
[kg/m3]
[kJ/(kgK)]
No:
No:
% of mass
No:
No:

Does the liquid get sticky when volatiles evaporate from the pumped liquid?
Description of sticky circumstances:

Yes:

No:

Is the liquid hazardous/poisonous?


Yes:
No:
Special measures to be taken into account when dealing with this hazardous/poisonous liquid:

Special measures for handling this liquid:

CIP liquid (cleaning-in-place)


Type of liquid:
Chemical composition (if available):
Liquid temperature during operation:
Maximum liquid temperature:
Vapour pressure of liquid:
Liquid concentration:
Liquid pH value:

[C]
[C]
[bar]
%

169

27

TP, TPD, TPE

Key application data

Pump sizing
Main duty point:
Max. duty point:
Min. duty point:

[m3/h]
[m3/h]
[m 3/h]

Q:
Q:
Q:

H:
H:
H:

[m]
[m]
[m]

Ambient operating conditions


Ambient temperature:
Altitude above sea level:

[C]
[m]

Pressure
Minimum inlet pressure:
Maximum inlet pressure:
Discharge pressure (inlet pressure + head):

[bar]
[bar]
[bar]

ATEX marking
Required marking of the pump
Customers equipment group (e.g. II):
Customers equipment category (e.g. 2, 3):
Gas (G) and/or dust (D):

Gas (G):

Dust (D):

Gas and dust (G/D):

Required marking of the motor


Protection type (e.g. d, de, e, nA):
Maximum experimental safe gap (e.g. B, C):
Temperature class
- gas (e.g. T3, T4, T5):
- dust (e.g. 125 C):

[C]

Description/sketch
Detailed description of ATEX application
(attach a drawing if possible):

ATEX certificate required

Yes:

No:

Frequency converter
Frequency converter option wanted?
Control parameter:
Detailed description of requirements
(attach a drawing if possible):

Yes:
Pressure:

No:
Temperature:

Flow rate:

Other:

System information
Please provide us with information about your system and maybe a simple sketch. This will give us hints as to whether
you need accessories or monitoring equipment, or whether you already have a suitable system which makes it
unnecessary to attach any further equipment.

170

28

TP, TPD, TPE

Further product documentation

28. Further product documentation


WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
220,000 Grundfos products in more than
30 languages.
Information in WebCAPS is divided into six sections:
Catalogue
Literature
Service
Sizing
Replacement
CAD drawings.

Catalogue
Based on fields of application and pump types, this section
contains the following:
technical data
curves (QH, Eta, P1, P2, etc.) which can be adapted to the
density and viscosity of the pumped liquid and show the
number of pumps in operation
product photos
dimensional drawings
wiring diagrams
quotation texts, etc.

Literature
This section contains all the latest documents of a given pump,
such as
data booklets
installation and operating instructions
service documentation, such as Service kit catalogue and
Service kit instructions
quick guides
product brochures.

Service
This section contains an easy-to-use interactive service
catalogue. Here you can find and identify service parts of both
existing and discontinued Grundfos pumps.
Furthermore, the section contains service videos showing you
how to replace service parts.

171

28

TP, TPD, TPE

Further product documentation

Sizing

This section is based on different fields of application and


installation examples and gives easy step-by-step instructions in
how to size a product:
Select the most suitable and efficient pump for your
installation.
Carry out advanced calculations based on energy,
consumption, payback periods, load profiles, life cycle costs,
etc.
Analyse your selected pump via the built-in life cycle cost tool.
Determine the flow velocity in wastewater applications, etc.

Replacement
In this section you find a guide to selecting and comparing
replacement data of an installed pump in order to replace the
pump with a more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.
Based on an easy step-by-step guide, you can compare
Grundfos pumps with the one you have installed on your site.
When you have specified the installed pump, the guide will
suggest a number of Grundfos pumps which can improve both
comfort and efficiency.

CAD drawings
In this section, it is possible to download 2-dimensional (2D) and
3-dimensional (3D) CAD drawings of most Grundfos pumps.
These formats are available in WebCAPS:
2-dimensional drawings:
.dxf, wireframe drawings
.dwg, wireframe drawings.
3-dimensional drawings:
.dwg, wireframe drawings (without surfaces)
.stp, solid drawings (with surfaces)
.eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed
information on more than 220,000 Grundfos products
in more than 30 languages.
The program contains the same features and
functions as WebCAPS, but is an ideal solution if no
internet connection is available.
WinCAPS is available on DVD and updated once a
year.
Fig. 83 WinCAPS DVD

172

28

TP, TPD, TPE

Further product documentation

GO CAPS
Mobile solution for professionals on the GO!
CAPS functionality on the mobile
workplace.

173

174

175

V7152685 1013

GRUNDFOS A/S
DK-8850 Bjerringbro . Denmark
Telephone: +45 87 50 14 00
www.grundfos.com

The name Grundfos, the Grundfos logo, and be think innovate are registered trademarks owned by Grundfos Holding A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

ECM: 1121244
Copyright Grundfos Holding A/S

Vous aimerez peut-être aussi