Vous êtes sur la page 1sur 48

City of Kitchener Standard Drawings Index

100 Roads
100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 18.0m Local Road 20.0m Minor Collector 26.0m Major Collector 30.0m Secondary Arterial Residential Cul-De-Sac & Standard Utility Locations Flexible Pavement Design Curve Selection Data Flexible Pavement Design Frost Value Flexible Pavement Design Thickness Design Curves Perforated Sub-Drain Under Curb and Gutter Standard Drop Curb and Driveway Ramp Details Construction Details of Sidewalk Curb and Gutters Public Walkway Details Boulevard Tree Planting Concrete Paving - Sidewalk/Boulevard Adjacent to Boulevard Tree Walkway/Emergency Access Detail Temporary Road Detail Typical Curb and Intersection Sidewalk Ramp Detail Curb and Gutter with Adjacent Sidewalk Asphalt Joint Restoration Detail

200 Watermains
200 201 202 203 204 205 206 Dimensional Standards for Precast Valve Chamber for 300mm Gate Valve Dimensional Standards for Poured Valve Chamber for 450mm Gate Valve Dimensional Standards for Poured Valve Chamber for 600mm Gate Valve Standard Hydrant Installation Standard As Built Measurement for Watermain Construction Standard As Built Measurement for Watermain Construction Standard As Built Measurement for Watermain Construction

300 Sewers
300 301 302 303 304 305 306 307 308 Rainfall Intensity Curve Pipe Strength and Bedding Design Chart Type 'C' Manhole Poured Concrete Manhole Max. 6.10m Depth Precast Manhole Tee Precast Ditch Inlet with Sump Concrete Endwall with Apron for Storm Sewer Outlet Internal Grate (Oulets Only) for Corrugated Metal Pipe 750mm Diameter and Larger Downspout Connection Detail for Front Yard Infiltration Galleries Front Yard Infiltration Facility Detail

400 Lot Grading


400 401 402 403 404 Urban Lot Grading Type 'A' - Back to Front Drainage Urban Lot Grading Type 'B' - Split Drainage with Walkout Urban Lot Grading Type 'C' - Back to Front Drainage with Walkout Urban Lot Grading Type 'D' - Split Drainage Cross Section of Grass Swales

500 Parks and Community Trails


500 501 502 503 504 505 506 Fence Footing Backstop Layout Major Backstop Community Trail - Asphalt Community Trail - Stonedust Community Trail - Woodland Condition Walkway Block Sidewalk Terminus at Parkland

COMPUTED BY TYPE OF SEWER

CHECKED

PIPE STRENGTH AND BEDDING DESIGN PROJECT LOCATION


DEPTH OF COVER WIDTH OF TRENCH (top of pipe) BACKFILL MATERIAL TYPE
WEIGHT (kg/m)

DATE SHEET NO. OF

LOCATION

FROM M.H.

TO M.H.

STATIC LOAD (kg/m)

SUPERIMPOSED LOAD (kg/m)

TOTAL LOAD (kg/m)

SAFTY DESIGN FACTOR LOAD (kg/m)

BEDDING TYPE FACTOR

PIPE STRENGTH REQ'D


(kg/m)

PIPE SECTION DIA. TYPE CLASS

The Corporation Of The

SCALE: DATE: NO. REVISION DATE STANDARD NO.:

N.T.S. Jul-10 301

PIPE STRENGTH AND BEDDING DESIGN CHART

CITY OF KITCHENER