Design Data:
𝐿𝑜𝑎𝑑
Uniformly distributed partition wall load over the slabs = 𝐹𝑙𝑜𝑜𝑟 𝐴𝑟𝑒𝑎
𝐿𝑜𝑎𝑑
20% Reduction gives = 0.8 𝑥 𝐹𝑙𝑜𝑜𝑟 𝐴𝑟𝑒𝑎
𝑃𝑒𝑟𝑖𝑚𝑒𝑡𝑒𝑟 2 × (𝑙𝑎 + 𝑙𝑏 )
𝑚𝑖𝑛 = =
180 180
la
1|Page
CE 334 Lecture 1
𝑆𝑙𝑎𝑏 𝑡𝑖𝑐𝑘𝑛𝑒𝑠𝑠
o Self-weight= × 150 𝑝𝑠𝑓
12
o Floor Finish = 20 psf Dead Load
o Partition Wall = 100 psf (after Calculation)
Mb, neg
Factored Dead Load WU,DL= 1.4WDL
Factored Live Load WU, LL= 1.7 WLL
Factored Load = 1.4WDL + 1.7 WLL
Mb, pos
Step 3: Calculation of Moment
Mb, neg
𝑀𝑎,𝑝𝑜𝑠 = 𝑀𝑎,𝑝𝑜𝑠 ,𝑑𝑙 + 𝑀𝑎,𝑝𝑜𝑠 ,𝑙𝑙 = 𝐶𝑎,𝑝𝑜𝑠 ,𝑑𝑙 × 𝑊𝑢,𝑑𝑙 × 𝑙𝑎2 + 𝐶𝑎,𝑝𝑜𝑠 ,𝑙𝑙 × 𝑊𝑢,𝑙𝑙 × 𝑙𝑎2
𝑀𝑏,𝑝𝑜𝑠 = 𝑀𝑏,𝑝𝑜𝑠 ,𝑑𝑙 + 𝑀𝑏,𝑝𝑜𝑠 ,𝑙𝑙 = 𝐶𝑏,𝑝𝑜𝑠 ,𝑑𝑙 × 𝑊𝑢,𝑑𝑙 × 𝑙𝑏2 + 𝐶𝑏,𝑝𝑜𝑠 ,𝑙𝑙 × 𝑊𝑢,𝑙𝑙 × 𝑙𝑏2
Where,
𝑊𝑢 = 𝐹𝑎𝑐𝑡𝑜𝑟𝑒𝑑 𝐿𝑜𝑎𝑑
2|Page
CE 334 Lecture 1
4 8 8 8 8 8 8 8 3 7
9 2 2 2 2 2 2 9
9 8 8 8 8 8 8 4
5
6
CHARTS
Chart A1: Coefficients (Ca, neg) moment in slab along shorter direction
3|Page
CE 334 Lecture 1
Chart A2: Coefficients (Cb, neg) moment in slab along longer direction
Chart A3: Coefficients (Ca, dl) for dead load positive moment in slab along shorter direction
4|Page
CE 334 Lecture 1
Chart A4: Coefficients (Cb, dl) for dead load positive moment in slab along longer direction
Chart A5: Coefficients (Ca,ll) for live load positive moment in slab along shorter direction
5|Page
CE 334 Lecture 1
Chart A6: Coefficients (Cb,ll) for live load positive moment in slab along longer direction
𝑀𝑢
𝑑𝑟𝑒𝑞𝑢𝑖𝑟𝑒𝑑 = 𝑓𝑦
∅𝜌𝑓𝑦 𝑏(1 − 0.59𝜌 𝑓 ′ )
𝑐
dprovided>drequired; Ok
𝑀
𝑀𝑎𝑖𝑛 𝑟𝑒𝑖𝑛𝑓𝑜𝑟𝑐𝑒𝑚𝑒𝑛𝑡 = 𝐴𝑠 = 𝑎
∅𝑓𝑦 (𝑑 − 2 )
𝐴𝑠 𝑓𝑦
Check, 𝑎 = 0.85𝑓 ′ 𝑏
𝑐
6|Page
CE 334 Lecture 1
𝐴𝑠 𝑚𝑖𝑛𝑖𝑚𝑢𝑚 = 0.002 × 𝑏𝑡; (For Grade 40 bar); 𝐴𝑠 𝑚𝑖𝑛𝑖𝑚𝑢𝑚 = 0.0018 × 𝑏𝑡; (For Grade 60 bar)
o Special reinforcement should be provided at exterior corners in both the bottom and top of
the slab, for a distance in each direction from the corner equal to one-fifth the longer span
of the corner panel.
o The reinforcement at the top of the slab should be parallel to the diagonal from the corner,
while that at the bottom should be perpendicular to the diagonal.
Diagonal Type
Grid Type
L/4 L/2
L/4
Middle Strip
End Strip
End Strip
7|Page
CE 334 Lecture 1
8|Page