Académique Documents
Professionnel Documents
Culture Documents
(For Input/Output)
Applicable Fieldbus protocols
New
RoHS
Reduction in wiring time with SPEEDCON (Phoenix Contact). Just insert and make 1/2 rotation!
IP67
Note) Some products are IP40.
Handheld Terminal
Series SY3000/5000
Series SV1000/2000/3000
Series VQC1000/2000/4000
IP67
IP67
IP40
IP67
Series EX600
CAT.NA02-24C
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fieldbus System
Analog Unit
M12 connector (5 pins) Input Unit Output Unit Input/ Output Unit
SI Unit
Input device EtherCAT added to compatible communication networks
New
Flow sensor
2CH 2CH
2CH/ 2CH
Pressure sensor
Output device
IP67
Handheld Terminal
Parameter setting and I/O monitor tool
IP67 IP67
Input Unit
Input Unit
Power supply
End Plate
Digital Unit
Analog Unit
SI Unit
For detailed specifications of connectable device, refer to the catalog of each device and select the right device for your application. If anything is unclear, contact us.
Digital Unit
M12 connector (5 pins) Input Unit Output Unit Input/ Output Unit M8 connector (3 pins) D-sub connector Spring type terminal block
8 inputs 8 outputs
16 inputs
8 inputs
16 inputs 16 outputs
8 inputs/ 8 outputs
16 inputs 16 outputs
8 inputs/ 8 outputs
IP67
IP67
IP67
IP40
IP40
Pressure switch Others Proximate sensor Flow switch Photoelectric switch Auto switch
Limit switch
Input device
Output device
Features 1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
Parameters
A parameter is a set value to change the function and operation of the product through a PLC or Handheld Terminal. The desired operation for the customers application is realized by the set values. There are some parameters that can only be set using the Handheld Terminal of this series.
SI Unit
Unit to connect various Fieldbus with the EX600 system
How to Order Specifications Parts Description Dimensions
P. 1 P. 3 P. 9 P. 11
Digital Unit
Unit to input or output digital (switch) signals
Series SY (IP67)
P. 1 P. 5 P. 10 P. 12
Analog Unit
P. 17
Series SV (IP67)
P. 2 P. 7 P. 10 P. 12
End Plate
Unit to supply power to the EX600 system
How to Order Specifications Parts Description Dimensions
P. 25
P. 2 P. 8 P. 10 P. 11
Handheld Terminal
Parameter setting and I/O monitor tool
How to Order Specifications Parts Description Dimensions
P. 33
P. 2 P. 8 P. 9 P. 11
Accessories
Options including a power supply cable, etc. for the EX600 series
P. 13
P. 37
Safety Instructions Specific Product Precautions
Back cover
P. 49
Features 2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fieldbus System
Connection using D-sub connector
Cable with D-sub connector
IP40
These units are capable of connection using a D-sub connector. There are three types of units, for digital input, output, and input/output. The Digital Output Unit can be connected with an SMC manifold solenoid valve F kit (D-sub connector).
Manifold solenoid valve can be connected using cable with D-sub connector. Series SY Series S0700 Series SJ Series SQ Series SV Series VQC Series VQ
Please limit the number of valve connections to 16 stations for single and 8 stations for double. Refer to the catalog for each product for pin assignment details.
IP40
IP67
These terminal block units are compatible with individual wiring configurations. There are three types of units, for digital input, output, and input/output. Wiring connection to a sensor connector box, etc., can be carried out easily using only a flat head screwdriver.
These units input or output analog (voltage/current) signals. A single unit performs both input and output, allowing feedback control where analog signals are received from a pressure sensor and sent to a pressure controller. Installation space is minimized as well.
Counter function
It is possible to ascertain the maintenance period and identify the parts that require maintenance by an input and output signal ON/OFF counter function. When the counter function is enabled and a certain number of contact operations is reached, the display of counter will flash in red.
Note) The counter function is not provided with the Analog Unit.
Green ON Normal
Features 3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
Individual units can be connected and removed one by one.
A unique clamping method is adopted to prevent screws from falling out. It is easy to separate the unit just by loosening bracket screws.
It is also possible to add and remove stations of solenoid valves on the manifold one by one, but the method is different.
Handheld Terminal
Forced input and output function
The input and output signals are controlled forcedly without a PLC. The startup time after facility introduction can be shortened.
Can be used for the adjustment of internal parameters and the monitoring of input and output signal status.
Parameters: Analog data format Analog measurement range Input filter selection Counter function Open circuit detection function, etc.
Simple operation
Cursor button: Mode and setting change, etc. Function key: Value and command entry, etc.
Features 4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fieldbus System
Series EX600
How to Order
RoHS
SI Unit
EX600 S
Protocol
Symbol
Version
Symbol Description Nil When MJ or EN or EC is selected A When PR or DN is selected
PR DN MJ EN EC
Output type
Symbol
1 2
EX600 DX
Input type
Symbol
P N
B C C1 D E F
Number of Open circuit Connector inputs detection 8 inputs No M12 connector (5 pins) 4 pcs. 8 inputs No M8 connector (3 pins) 8 pcs. 8 inputs Yes M8 connector (3 pins) 8 pcs. 16 inputs No M12 connector (5 pins) 8 pcs. 16 inputs No D-sub connector (25 pins) Note1) 2) Spring type terminal block (32 pins) Note1) 2) 16 inputs No
EX600 DY
Output type
Symbol
P N
B E F
Number of Connector outputs 8 outputs M12 connector (5 pins) 4 pcs. 16 outputs D-sub connector (25 pins) Note1) 2) 16 outputs Spring type terminal block (32 pins) Note1) 2)
EX600 DM
Input/Output type
Symbol
P N
Note 1) Cannot be communicated with the EX600-HT1-. Refer to page 15 for a table of mountable units. Note 2) Cannot be connected with the EX600-SPR1, EX600-SPR2, EX600-SDN1, or EX600-SDN2. Refer to page 15 for a table of mountable units.
1
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fieldbus System
Series EX600
How
rder
EX600 AX
Analog input Number of input channels and connector
Symbol
EX600 AY
Analog output Number of output channels and connector
Symbol
EX600 AM
Analog input/output Number of input/output channels and connector
Symbol Number of input Number of output channels channels 2 channels 2 channels Connector M12 connector (5 pins) 4 pcs. Note1) 2)
End Plate
EX600 ED
Power connector
Symbol
Mounting method
Symbol Nil Description Without DIN rail mounting bracket With DIN rail mounting bracket With DIN rail mounting bracket (Specialized for Series SY)
2 3
2 3
Handheld Terminal
EX600 HT1A
Version Cable length
Symbol Nil Description No cable 1m 3m
1 3
Note 1) Cannot be communicated with the EX600-HT1-. Refer to page 15 for a table of mountable units. Note 2) Cannot be connected with the EX600-SPR1, EX600-SPR2, EX600-SDN1, or EX600-SDN2. Refer to page 15 for a table of mountable units.
2
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
SI Unit Specifications
All Units Common Specifications
Environmental resistance Operating temperature range Storage temperature range Operating humidity range Withstand voltage Note) Insulation resistance Note) 14 to 122F 4 to 140F 35 to 85% RH (No dew condensation) 500 VAC for 1 minute between external terminals and FE 500 VDC, 10 M or more between external terminals and FE
SI Unit (EX600-SPRA)
Model Protocol Communication Device type Communication speed Configuration file I/O occupation area (Inputs/Outputs)
EX600-SPR1A
PROFIBUS DP Slave
EX600-SPR2A
PROFIBUS DP (DP-V0) 9.6/19.2/45.45/93.75/187.5/500 kbps 1.5/3/6/12 Mbps GSD file Max. (512 inputs/512 outputs) Internally implemented 80 mA or less PNP (Negative common) NPN (Positive common)
EX600-SPRA
Terminating resistor Internal current consumption (Power supply for Control/Input) Output type Number of outputs Output Load Power supply Fail safe Protection Enclosure Standards Weight
32 outputs (8/16/24/32 outputs selectable) Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC) 24 VDC, 2 A HOLD/CLEAR/Forced power ON Short-circuit protection IP67 (Manifold assembly) CE marking, UL (CSA), RoHS recognition 0.6 lbs (300 g)
SI Unit (EX600-SDNA)
Model Protocol Device type Communication Communication speed Configuration file I/O occupation area (Inputs/Outputs)
EX600-SDN1A
Group 2 Only Server 125/250/500 kbps EDS file
EX600-SDN2A
Max. (512 inputs/512 outputs) Duplicate MAC ID Check Message Group 2 Only Unconnected Explicit Message Explicit Message (Group 2) Poll I/O Message (Predefined M/S Connection set) 11 to 25 VDC 55 mA or less PNP (Negative common) NPN (Positive common) 32 outputs (8/16/24/32 outputs selectable) Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC) 24 VDC, 2 A HOLD/CLEAR/Forced power ON Short-circuit protection IP67 (Manifold assembly) CE marking, UL (CSA), RoHS recognition 0.6 lbs (300 g)
EX600-SDNA
Applicable messages
DeviceNet power supply Internal current consumption (Power supply for Control/Input) Output type Number of outputs Output Load Power supply Fail safe Protection Enclosure Standards Weight
3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fieldbus System
Series EX600
SI Unit (EX600-SMJ)
Model
EX600-SMJ1
Remote Device Station 156/625 kbps 2.5/5/10 Mbps
EX600-SMJ2
Communication
Max. (512 inputs/512 outputs) 1/2/3/4 stations occupied 75 mA or less PNP (Negative common) NPN (Positive common) 32 outputs (8/16/24/32 outputs selectable) Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC) 24 VDC, 2 A HOLD/CLEAR/Forced power ON Short-circuit protection IP67 (Manifold assembly) CE marking, UL (CSA), RoHS recognition 0.6 lbs (300 g)
EX600-SMJ
Output
Number of outputs Load Power supply Fail safe Protection Enclosure Standards Weight
SI Unit (EX600-SEN)
Model Protocol Media Communication speed Communication method Configuration file I/O occupation area (Inputs/Outputs) IP address setting range Device information Internal current consumption (Power supply for Control/Input) Output type Number of outputs PNP (Negative common)
EX600-SEN1
100 BASE-TX
EX600-SEN2
EtherNet/IP (Conformance version: Composite 6) 10/100 Mbps (Automatic/Manual) Full duplex/Half duplex (Automatic/Manual) EDS file Max. (512 inputs/512 outputs) SI Unit switch settings: 192.168.0 or 1.1 to 254 Through DHCP server: Optional address Vendor ID: 7 (SMC Corporation) Product type: 12 (Communication Adapter) Product code: 126 120 mA or less NPN (Positive common)
EX600-SEN
Communication
32 outputs (8/16/24/32 outputs selectable) Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC) 24 VDC, 2 A HOLD/CLEAR/Forced power ON Short-circuit protection IP67 (Manifold assembly) CE marking, UL (CSA), RoHS recognition 0.6 lbs (300 g)
Output
SI Unit (EX600-SEC)
Model
EX600-SEC1
100 Mbps XML file
EX600-SEC2
Communication
Max. (512 inputs/512 outputs) 100 mA or less PNP (Negative common) NPN (Positive common)
Internal current consumption (Power supply for Control/Input) Output type Number of outputs
32 outputs (8/16/24/32 outputs selectable) Solenoid valve with surge voltage suppressor 24 VDC, 1.5 W or less (SMC) 24 VDC, 2 A HOLD/CLEAR/Forced power ON Short-circuit protection IP67 (Manifold assembly) CE marking, UL (CSA), RoHS recognition 0.6 lbs (300 g)
Output
EX600-SEC
4
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
Digital Unit Specifications
Digital Input Unit
Model Input type Input connector Number of inputs Supplied voltage Max. supplied current 0.5 A/connector 2 A/unit
EX600-DXB
Input
Protection Input current (at 24 VDC) ON voltage OFF voltage Open circuit detection current
EX600-DXC
Note 1) M12 (4-pin) connector can be connected. Note 2) Function only applies to the EX600-DXC1.
EX600-DXPE
PNP
EX600-DXNE
NPN
EX600-DXPF
PNP
EX600-DXNF
NPN
Spring type terminal block (32 pins) 16 inputs (2 inputs x 8 blocks) 24 VDC 0.5 A/block 2 A/unit
EX600-DXD
Input
Supplied voltage Max. supplied current Protection Input current (at 24 VDC) ON voltage OFF voltage Applicable wire 2 A/unit
Short-circuit protection 5 mA or less 17 V or more (At NPN input, between the pin for input terminal and supplied voltage of +24 V) (At PNP input, between the pin for input terminal and supplied voltage of 0 V) 5 V or less (At NPN input, between the pin for input terminal and supplied voltage of +24 V) (At PNP input, between the pin for input terminal and supplied voltage of 0 V) 50 mA or less IP40 (Manifold assembly) CE marking, UL (CSA), RoHS recognition 0.6 lbs (300 g) 0.08 to 1.5 mm2 (AWG16 to 28) 55 mA or less
EX600-DXE
EX600-DXF
5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fieldbus System
Series EX600
EX600-DYB
EX600-DYE EX600-DME
EX600-DMPE
PNP
EX600-DMNE
NPN
EX600-DMPF
PNP
EX600-DMNF
NPN
Spring type terminal block (32 pins) 8 inputs (2 inputs x 4 blocks) 24 VDC 0.5 A/block 2 A/unit
EX600-DYF EX600-DMF
Protection Input current (at 24 VDC) ON voltage OFF voltage Number of outputs
Output
6
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
Analog Unit Specifications
Analog Input Unit
Model Input type Input connector Input channel Supplied voltage Max. supplied current Input Protection
12 bit resolution Input signal range 16 bit resolution
EX600-AXA
Voltage input M12 (5-pin) socket Note 1) 2 channels (1 channel/connector) 24 VDC 0.5 A/connector Short-circuit protection 0 to 10 V, 1 to 5 V, 0 to 5 V 10 to 10 V, 5 to 5 V 15 V 100 k 0.05% F.S. 0.15% F.S. 0.5% F.S. 70 mA or less IP67 (Manifold assembly) CE marking, UL (CSA), RoHS recognition 0.6 lbs (290 g) 0.6% F.S. 0 to 20 mA, 4 to 20 mA 20 to 20 mA 22 mA Note 2) 50 Current input
EX600-AXA
Max. rated input signal Input impedance Linearity (77F) Repeatability (77F) Absolute accuracy (77F) Current consumption Enclosure Standards Weight
Note 1) M12 (4-pin) connector can be connected. Note 2) When input signal exceeds 22 mA, the protection function activates and the input signal is interrupted.
EX600-AYA
Current output
EX600-AYA
7
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fieldbus System
Series EX600
EX600-AMB
Current input
EX600-AMB
Note 1) M12 (4-pin) connector can be connected. Note 2) When input signal exceeds 22 mA, the protection function activates and the input signal is interrupted.
End Plate
Model
Power specification
EX600-ED2-
M12 (5-pin) plug 24 VDC 10%, Class 2, 2 A 24 VDC +10/5%, Class 2, 2 A
EX600-ED3-
7/8 inch (5-pin) plug 24 VDC 10%, 8 A 24 VDC +10/5%, 8 A
Power connector Power supply (for Control/Input) Power supply (for Output)
IP67 (Manifold assembly) CE marking, UL (CSA), RoHS recognition 0.4 lbs (175 g)
EX600-ED3- EX600-ED2-
Handheld Terminal
Model Power supply Current consumption Display Connection cable Enclosure
EX600-HT1A-
Power supplied from SI Unit connector (24 VDC) 50 mA or less LCD with backlight Handheld Terminal cable (1 m EX600-AC010-1, 3 m EX600-AC030-1) IP20 CE marking, RoHS recognition 0.35 lbs (160 g)
EX600-HT1A-
Standards Weight
8
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
Parts Description
SI Unit w q
e r t y
No. 1 2 3 4 Description Status indication LED Indication cover Indication cover set screw Connector (BUS OUT) Marker groove Connector (PCI) Use Displays unit status. Open for setting the switch. Loosen for opening the indication cover. Connects to the fieldbus output cable. Can be used to mount a marker. Connects to the Handheld Terminal cable.
!1 !0
EX600-SPRA EX600-SMJ EX600-SDNA
u i qw
t y !2
7 8 9 10 11
Valve Plate mounting holes Fixes Valve Plate in place. Valve Plate mounting groove Inserts Valve Plate. Joint bracket Connector for unit (Plug) Connector (BUS IN) MAC address name plate Seal cap Links units to one another. Transmits signals to the neighboring unit and supplies power. Connects to the cable for fieldbus input. Displays a unique 12-digit MAC address for each SI Unit. Mounted on the connectors (BUS OUT and PCI) at the time of shipment.
q w
e r t y !1 !0
u i o EX600-SEN !3
12 13
!1 !0 q
EX600-SEC
u i o
Handheld Terminal
No. Description LCD Connector Handheld Terminal cable Use Displays operation and unit information. Connects to the Handheld Terminal cable. Connects the SI Unit to the Handheld Terminal. From the selection screen, goes to the screen for the item selected. On the settings screen, registers the settings that have been made so far. Moves the cursor on the LCD up, down, left or right. Moves the cursor on the selection screen up, down, left or right to make selections. On the settings screen, increases or decreases the value of settings or turns settings on and off. Functions in accordance with on-screen display or instructions. Functions in accordance with on-screen display or instructions. On the selection screen, goes back to the previous screen. On the settings screen, cancels the settings that have been made so far and goes back to the previous screen. Lights up red when the EX600 diagnosis errors occur. Connects to the EX600 SI Unit, and lights up green when control/input power supply is on.
1 2 3
Enter button (
w r
Cursor button ( )
!0 o
6 7
F2 button ( F1 button (
) )
t
8 Escape button ( )
ERROR LED
10
POWER LED
u 9
Operation buttons
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Fieldbus System
Series EX600
Digital Unit
No.
Description Status indication LED Connector Marker groove Lock screw Joint bracket Connector for unit (Plug)
Use Displays unit status. Connects with input or output devices. Can be used to mount a marker. Fixes the D-sub connector in place. (No.4-40 UNC) Links units to one another. Transmits signals to the neighboring unit and supplies power.
1 2 3 4 5 6
y
EX600-DXB EX600-DYB
y t q
EX600-DXC
t q w e r q w e
w e
y
EX600-DXD
y t
EX600-DXE EX600-DYE EX600-DME
y t
EX600-DXF EX600-DYF EX600-DMF
Analog Unit
No. 1 2 3 4 5
Description Status indication LED Connector Marker groove Joint bracket Connector for unit (Plug)
Use Displays unit status. Connects with input or output devices. Can be used to mount a marker. Links units to one another. Transmits signals to the neighboring unit and supplies power.
t
EX600-AXA EX600-AYA
t r
EX600-AMB
End Plate
No. 1
Description Power connector Fixing hole for direct mounting Fixing hole for DIN rail FE terminal Connector (Unused)
Use Supplies power to the unit and/or input/output devices. Connects directly to equipment. Converts to manifold or for DIN rail mounting. Connects for grounding to FE (Functional Earth). This connector has not yet been used. Do not remove the seal cap.
2 3 4
e r w
e r e w
EX600-ED2-
EX600-ED3-
10
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
Dimensions
SI Unit
EX600-SPRA EX600-SDNA EX600-SMJ
55.2 47 26 10.7
EX600-SEN EX600-SEC
55.2 47 26
10.7
106
22
106
11.5
22
56.4
56.4
106.5
End Plate
EX600-ED2
85.1 8 20.5 5.5 8
22.1
22.1
23.7
EX600-ED3
42.5 26 20.5
5.5
106 90
30.35
Handheld Terminal
11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
76
Fieldbus System
Series EX600
(mm)
Digital Unit
EX600-DXB EX600-DYB
10.7 52.5 47 20
EX600-DXC
EX600-DXD
10.7
52.5 47 23
10.7
52.5 47 20
106
106
106 81 27
0.3
43.5 14.5
37
56.4
56.4
56.4
22.1
22.1
56.4
3 22.1
Analog Unit
EX600-DXF EX600-DYF EX600-DMF
10.7 10.7 52.5 47
EX600-AXA EX600-AYA
52.5 47 20 10.7
EX600-AMB
106
106
106
2.2
56.4
22.1
56.4
56.4
22.1
22.1
37
22.1 52.5 47 20
106
12
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
Accessories
Power supply cable with M12 connector I/O cable with connector Seal cap (M8) Communication cable with connector
Reinforcing brace (for DIN rail mounting) End Plate bracket 7/8 inch fieldwireable connector
EX600-ZMA2
EX600-ZMA3
(Specialized for Series SY)
Enclosed parts
Round head screw (M4 x 20) 1 pc. P-tight screw (4 x 14) 2 pcs.
Enclosed parts
Round head screw with washer (M4 x 20) 1 pc. P-tight screw (4 x 14) 2 pcs.
Valve Plate
EX600-ZMV1
EX600-ZMV2
(Specialized for Series SY)
Enclosed parts
Round head screw (M4 x 6) 2 pcs. Round head screw (M3 x 8) 4 pcs.
Enclosed parts
Round head screw (M4 x 6) 2 pcs. Round head screw (M3 x 8) 4 pcs.
13
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Accessories
Reinforcing brace
Series EX600
This bracket is used on the bottom of the unit at the intermediate position for connecting 6 units or more.
EX600-ZMB1
EX600-ZMB2
Enclosed parts
Round head screw (M4 x 5) 2 pcs.
Enclosed parts
Round head screw (M4 x 6) 2 pcs.
EX9-AWES
For M8
EX9-AWTS
For M12
EX600-ZT1
Note) For M12 connector, description of B-coded for a reverse type is used as a connector shape.
Straight 5 m PCA-1446566
The communication cable with connector and the communication connector that can be used on this series other than EtherNet/IP and EtherCAT are found in the M8/M12 connector catalog.
14
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
Table of Mountable Units
The units that can be connected differ depending on the product number. Before mounting, please be sure to confirm the types of units that can be connected.
Product number SI Unit
EX600-SPR
(PROFIBUS DP)
EX600-SPRA
(PROFIBUS DP)
EX600-SEN EX600-SMJ
(CC-Link) Version Nil (EtherNet/IP)
EX600-SDN
(DeviceNet)
EX600-SDNA
(DeviceNet) Version
EX600-SEC
(EtherCAT) Version Nil
Version Nil
Product number
EX600-HT1-
Version Nil
EX600-HT1A-
Version
EX600-SPRA
(PROFIBUS DP)
EX600-SDN
(DeviceNet) SI Unit
EX600-SDNA
(DeviceNet)
EX600-SMJ
(CC-Link)
EX600-SEN
Product number (EtherNet/IP)
EX600-SEC
(EtherCAT)
Digital Input/Output Unit Analog Input Unit Analog Output Unit Analog Input/Output Unit
EX600-DXB EX600-DXC EX600-DXD EX600-DXE EX600-DXF EX600-DYB EX600-DYE EX600-DYF EX600-DME EX600-DMF EX600-AXA EX600-AYA EX600-AMB
15
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SY3000/5000
P. 17
Series SV1000/2000/3000
P. 25
Series S0700
P. 33
Series VQC1000/2000/4000
P. 37
16
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
RoHS
Series SY3000/5000
How to Order Manifold
Refer to the SY3000/5000 series catalog (CAT.ES11-103) for Type 11/Bottom ported dimensions. Series
3 5
SY3000 SY5000
SS5Y 3
10 S6 Q
05 U C6
Valve stations
Symbol Stations
02
2 stations
Type
10 11
Side ported Bottom ported
Nil
2 4
3 5
The SY5000 manifold base is used for mixed mounting of the SY3000/5000 and bottom ported of the SY3000. When ordering, refer to How to Order Manifold (for plug-in mixed mounting) in the SY series catalog.
1 9
SI Unit
Without SI Unit For DeviceNet For PROFIBUS DP For CC-Link For EtherNet/IP For EtherCAT Note 1) I/O Unit cannot be mounted without SI Unit. Note 2) Valve Plate which connects manifold and SI Unit is not mounted to a valve without SI Unit. Refer to page 51 for mounting method.
0 Q N V ZE D
Note 1) Without SI Unit, the symbol is nil. Note 2) SI Unit is not included in I/O Unit stations. Note 3) When I/O Unit is selected, it is shipped separately, and assembled by customer. Refer to the attached operation manual for mounting method. Note 4) Refer to page 50 for details on enclosure.
Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold stations. Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly.
External pilot
P, E port entry U side (2 to 10 stations) P, E port entry D side (2 to 10 stations) P, E port entry both sides (2 to 24 stations)
U D B
C E F
G H J
3/5 (E) port is plugged for the built-in silencer type. When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. Refer to the page on the right for .
B A B A B A B A B A
14 A
14 A
14 A
14 A
14 A
D side
PWR OUT
0 4 5 2
1 3 BUS IN
12 B 12 B 12 B 12 B 12 B
U side
PCI BUS OUT
Mounting
Nil
Valve stations
SS5Y3-10S6Q42-05B-C6 1 set (Type 10 5-station manifold base part no.) SY3100-5U1 3 sets (2-position single part no.) SY3200-5U1 2 sets (2-position double part no.) EX600-DXPD 1 set I/O Unit part number (Station 1) EX600-DYPB 1 set I/O Unit part number (Station 2) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the valve, etc. The valve arrangement is numbered as the 1st station from the D side. Under the manifold part number, state the valves to be mounted, then the I/O Units in order from the 1st station as shown in the figure above. If the arrangement becomes complicated, specify on a manifold specification sheet. Note 1) Do not enter the SI Unit part number and the End Plate part number together. Note 2) When mixing top ported configurations, select from page 24. Specify on a manifold specification sheet if plugs are reguired on the A and B port on the manifold.
D D0 D3 D24
Direct mounting DIN rail mounting (With DIN rail) DIN rail mounting (Without DIN rail) For 3 stations Specify a longer rail than the standard length. For 24 stations
Only direct mounting is available for Type 11 (Bottom ported). When it is necessary to mount a DIN rail without an SI Unit, select D0 and order the DIN rail with required length separately by referring to L3 in the dimensions. When selecting the DIN rail mounting (with DIN rail) of the SY5000 series with the End Plate to a power supply 7/8 inch connector, 9 I/O Unit stations will result in a total of 23 valve stations. With 24 stations, the DIN rail mounting (with DIN rail) cannot be indicated, so please exercise caution. (Refer to DIN Rail Overall Length on pages 19 to 22.)
Refer to the catalog of each series for details on manifold solenoid valve specifications, Common Precautions and Specific Product Precautions.
17
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SY3000/5000
A, B port 2 One-touch fitting Straight 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting Straight port, mixed sizes Downward Upward 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting
Symbol
A, B port 1/8" One-touch fitting Straight 5/32" One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting Straight port, mixed sizes Downward Upward 5/32" One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting 5/32" One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting
C2 C3 C4 C6 C8 CM L4 L6 L8 B4 B6 B8 LM
b b b b
Elbow
b b b
b b
b b b b b b b b b b b
10
b b b b
10
b b b
b b b
b b b b
b b b b
3/8"
Elbow
b b
b b
b b b
3/8"
b
5/16"
b
8
Indicate the sizes on the manifold specification sheet in the case of CM and LM. The direction of P, E port fittings is the same as for A, B port. If selecting LM, indicate it on the manifold specification sheet for the P, E port fitting direction.
SY 3 1 0 0
Series
3 5 1 2 3 4 5 A B C
SY3000 SY5000
1
Manual override
Nil: NonD: Push-turn F: Slide locking locking slotted locking push type type type
Type of actuation
2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.)
B K
Only metal seal type is available for the high pressure type.
Coil type
Nil Standard
With power saving circuit (Continuous duty type)
Only rubber seal type is available for 4-position dual 3-port valves.
Seal type
0 1
Rubber seal Metal seal
Be sure to select the power saving circuit type when the valve is continuously energized for long periods of time. The product with power saving circuit is not available for the quick response type.
Rated voltage
5
24 VDC
B K H
Pilot type
Nil
With mounting screw (Round head combination screw) With mounting screw (Hexagon socket head cap screw) With mounting screw (Round head combination screw, falling-out-prevention type) With mounting screw (Hexagon socket head cap screw, falling-out-prevention type)
For K and H, mounting screws do not fall out from the valve. (An apparatus to prevent falling-out is provided on the valve body cover.) When ordering a valve individually, the base gasket is not included. Since the base gasket is attached to the manifold, please order the base gasket separately if it is needed for maintenance service. Refer to the SY3000/5000 series catalog (CAT.ES11-103) for details. B and H cannot be selected for the individual SUP/EXH spacer assembly or double check spacer assembly with residual pressure release valve.
None Built-in
Only rubber seal type. Manifold installed type is available if the back pressure check valve is required for a valve with metal seal, Refer to the SY3000/5000 series catalog (CAT.ES11-103) for details. However, it is not recommended to use the built-in valve type and the manifold installed type at the same time because it will reduce the flow. The built-in valve type back pressure check valve is not available for the 3-position type.
Only Z and NZ types are available for the product with power saving circuit. Select a valve from R, U, S or Z when the SI Unit common is positive common. Select a valve from R, U, NS or NZ when the SI Unit common is negative common.
18
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SY3000/5000
Dimensions: Type 10/For EX600 (M12 Connector)/Series SY3000
C3, N1 SS5Y3-10S6 2 4 - Stations D - C4, N3 (D)
D side 5.3 (mm)
U C2
B C6, N7
L3 L4
(DIN rail mounting hole pitch: 12.5)
U side
(L5)
DIN rail holding screw 5.5 (For DIN rail mounting) Power connector 85.1
L1 L6
Communication connector 2 x M4 mounting hole Marker groove 47 8
L2
DIN rail holding screw 1.5 (For DIN rail mounting) Light/surge voltage suppressor
Manual override Note 2) Push-turn locking slotted type: Press, then rotate it. 4(A) port side : Blue (For rubber seal) : Gray (For metal seal) 2(B) port side : Yellow
B A B A B A B A B A
35
106
0 4 5 2
1
12 B 12 B 12 B 12 B 12 B
BUS IN 8 7
PCI
BUS OUT
4.6
40.9
PWR OUT
90
86.6
5.4 End Plate Digital Input Unit Input connector Output connector Digital Output Unit
(4.9)
4 x M4 mounting hole (Fitting for the type with P/E ports on the U and/or D sides)
Valve Plate SI Unit Connector for Handheld Terminal One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 2 : 3.2, 1/8" : 4, 5/32" : 6, 1/4"
11.5
(Station 1) 8
(Station n)
56.6
13.2
3/5
B2
B2
B2
B2
3/5
A4
A4
A4
A4
10.6
7.5
18.3 15.5
(Pitch) P = 10.5
(17.8)
Note 1) These figures show the SS5Y3-10S6Q22-05D-C6. Note 2) Refer to the SY3000/5000 series catalog (CAT.ES11-103) for dimensions of external pilot, silencer, elbow fittings and slide locking manual override. Note 3) Refer to the SY3000/5000 series catalog (CAT.ES11-103) for dimensions of A or B port top-ported type.
6
223
10
11
12
13
14
15
16
17
18
348
19
20
13.6
21
18
1.7
22
83
14 A
14 A
14 A
14 A
14 A
92.6
5.5
5.1
23
24
0 1 2 3 4 5 6 7 8 9
285.5 285.5 298 323 335.5 348 385.5 398 435.5 448 473
335.5 348
385.5 385.5 398 435.5 448 485.5 498 535.5 548 573
285.5 285.5 298 335.5 348 385.5 398 435.5 448 473
510.5 510.5 523 560.5 573 610.5 623 660.5 673 698
410.5 410.5 423 460.5 473 510.5 523 560.5 573 598
510.5 510.5 523 560.5 573 610.5 623 660.5 673 698
635.5 635.5 648 685.5 698 735.5 748 785.5 798 835.5 835.5
710.5 723
19
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SY3000/5000
(mm)
U C2
C6, N7
U side
L3 L4
(L5)
5.5 DIN rail holding screw (For DIN rail mounting)
L1 L6
47 2 x M4 mounting hole Marker groove 8
L2
DIN rail holding screw 1.5 (For DIN rail mounting) Light/surge voltage suppressor
Manual override Note 2) Push-turn locking slotted type: Press, then rotate it. 4(A) port side : Blue (For rubber seal) : Gray (For metal seal) 2(B) port side : Yellow
B A B A B A B A B A
35
106
90
0 4 5 2
1
12 B 12 B 12 B 12 B 12 B
53
BUS IN 8 7
PCI
BUS OUT
4.6
40.9
(4.9)
FE terminal 5.4 End Plate Digital Input Unit Input connector Output connector Digital Output Unit 11.5
(Fitting for the type with P/E ports on the U and/or D sides) Valve Plate SI Unit Connector for Handheld Terminal (Station 1) (Station n) One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 2 : 3.2, 1/8" : 4, 5/32" : 6, 1/4"
56.6
13.2
3/5
B2
B2
B2
B2
3/5
A4
A4
A4
A4
1.7
4 x M4 mounting hole
10.6
7.5
18.3 15.5
(Pitch) P = 10.5
(17.8)
Note 1) These figures show the SS5Y3-10S6Q32-05D-C6. Note 2) Refer to the SY3000/5000 series catalog (CAT.ES11-103) for dimensions of external pilot, silencer, elbow fittings and slide locking manual override. Note 3) Refer to the SY3000/5000 series catalog (CAT.ES11-103) for dimensions of A or B port top-ported type.
2
198 248 298 348
10
11
12
13
14
323
15
16
17
18
19
20
13.6
21
18
22
83
14 A
14 A
14 A
14 A
14 A
92.6
5.5
PWR
5.1
23
24
435.5 485.5 523
0 1 2 3 4 5 6 7 8 9
260.5 260.5 273 310.5 323 360.5 373 410.5 423 448
310.5 323
385.5 385.5 398 423 435.5 448 485.5 498 535.5 548
385.5 385.5 398 435.5 448 485.5 498 535.5 548 573
485.5 485.5 498 535.5 548 585.5 598 635.5 648 673
560.5 573 610.5 623 660.5 673 710.5 710.5 760.5 810.5 860.5
385.5 398 435.5 448 485.5 498 535.5 548 573 623
610.5 610.5 623 660.5 673 710.5 723 760.5 773 798
810.5 823
20
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SY3000/5000
Dimensions: Type 10/For EX600 (M12 Connector)/Series SY5000
SS5Y5-10S6 2 4 - Stations D - C6, N7 (D)
B C8, N9
D side 5.3 DIN rail holding screw (For DIN rail mounting) Power connector DIN rail 2 x M4 mounting hole 85.1 Marker groove
0 1
(mm)
C4, N3
L3 L4
(DIN rail mounting hole pitch: 12.5)
U side
(L5)
5.5
L1 L6
Communication connector 47 8
L2
DIN rail holding screw (For DIN rail mounting) 1.5
Manual override Note 2) Push-turn locking slotted type: Press, then rotate it. 4(A) port side : Blue (For rubber seal) : Gray (For metal seal) 2(B) port side : Yellow
35
BA 14 A
BA 14 A
BA 14 A
BA 14 A
BA 14 A
5.5
PWR OUT
0 4 5 2
1 3 BUS IN
PCI
7.4
12 B
12 B
12 B
12 B
12 B
15.4
86.6 FE terminal
5.4 End Plate Digital Input Unit Input connector Output connector Digital Output Unit 11.5
(8.3)
(5.9)
(Fitting for the type with P/E ports on the U and/or D sides) One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 4, 5/32" : 6, 1/4" : 8, 5/16"
56.6
B2
B2
B2
B2
B 3/5 E
13.2
3/5
E 4 A4 A4 A4 A4 A
7.5
One-touch fitting [1(P), 3/5(E) port] Applicable tube O.D.: 10, 3/8"
20
18
(Pitch) P = 16
(20.5)
Note 1) These figures show the SS5Y5-10S6Q22-05D-C8. Note 2) Refer to the SY3000/5000 series catalog (CAT.ES11-103) for dimensions of external pilot, silencer, elbow fittings and slide locking manual override. Note 3) Refer to the SY3000/5000 series catalog (CAT.ES11-103) for dimensions of A or B port top-ported type.
12.4
8.7
(mm)
2
198 248 298 348
3
223
6
273
10
11
12
13
14
398 448
15
16
17
448
18
19
20
21
22
23
0 1 2 3 4 5 6 7 8 9
485.5 510.5 523 535.5 548 585.5 598 698 748 573 623
535.5 560.5 585.5 598 635.5 648 748 785.5 835.5 885.5
385.5 410.5 423 435.5 448 485.5 498 535.5 548 573 623 598 648
21
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
73.2
4.7
4 x M5 mounting hole
5.5
BUS OUT
24
113.4
90
Series SY3000/5000
(mm)
U C4, N3
L3 L4
(DIN rail mounting hole pitch: 12.5)
U side
(L5)
5.5 DIN rail holding screw (For DIN rail mounting) DIN rail 16.5
L1 L6
2 x M4 mounting hole Communication connector Marker groove
0 1
L2
47 8 DIN rail holding screw (For DIN rail mounting) 1.5
Manual override Note 2) Push-turn locking slotted type: Press, then rotate it. 4(A) port side : Blue (For rubber seal) : Gray (For metal seal) 2(B) port side: Yellow
90
35
BA 14 A
BA 14 A
BA 14 A
BA 14 A
BA 14 A
5.5
0 4 5 2
1 3 BUS IN
60.4
BUS OUT 12 B 12 B 12 B 12 B 12 B
7.4
15.4
(8.3)
(5.9)
FE terminal
5.4 End Plate Digital Input Unit Valve Plate Input connector Output connector Digital Output Unit SI Unit Connector for Handheld Terminal (Station 1) (Station n)
4 x M5 mounting hole (Fitting for the type with P/E ports on the U and/or D sides) One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 4, 5/32" : 6, 1/4" : 8, 5/16"
11.5
56.6
B2
B2
B2
B2
13.2
A4
A4
A4
A4
8.7
12.4
7.5
One-touch fitting [1(P), 3/5(E) port] Applicable tube O.D.: 10, 3/8"
20
18
(Pitch) P = 16
(20.5)
Note 1) These figures show the SS5Y5-10S6Q32-05D-C8. Note 2) Refer to the SY3000/5000 series catalog (CAT.ES11-103) for dimensions of external pilot, silencer, elbow fittings and slide locking manual override. Note 3) Refer to the SY3000/5000 series catalog (CAT.ES11-103) for dimensions of A or B port top-ported type.
14.1
29.1
3/5
3/5
(mm)
2
223
5
273
10
11
12
13
14
15
16
448
17
18
19
20
21
22
23
24
0 1 2 3 4 5 6 7 8 9
235.5 248
535.5 560.5 573 585.5 598 635.5 648 748 623 660.5 710.5 760.5
260.5 285.5 298 310.5 335.5 348 360.5 373 410.5 423 460.5 473 498 548 598 648 523 398
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
73.2
4.7
5.5
61.7
PCI
81.2
22
113.4
PWR
RoHS
Series SY3000/5000
How to Order Manifold
Refer to the SY3000/5000 series catalog (CAT.ES11103) for Type 12/Top ported dimensions. Series
3 5
SY3000 SY5000
SS5Y 3 12S6 Q
I/O Unit stations
Nil
05 U
Valve stations
Symbol Stations 02 2 stations Note Double wiring Note 1)
1 9
Note 1) Without SI Unit, the symbol is nil. Note 2) SI Unit is not included in I/O Unit stations. SI Unit Note 3) When I/O Unit is selected, it is 0 Without SI Unit shipped separately, and assembled Q For DeviceNet by customer. Refer to the attached N For PROFIBUS DP operation manual for mounting V For CC-Link method. ZE For EtherNet/IP Note 4) Refer to page 50 for details on D For EtherCAT enclosure. Note 1) I/O Unit cannot be mounted without SI Unit. Note 2) Valve Plate which connects manifold and SI Unit is not mounted to a valve without SI Unit. Refer to page 51 for mounting method.
For mixed mounting of the SY3000/5000 series, refer to How to Order Manifold (for plug-in mixed mounting) in the SY series catalog.
16 02 24
Note 1) Double wiring: 2-position single, double, 3-position and 4-position valves can be used on all manifold stations. Use of a 2-position single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that 2-position double, 3-position and 4-position valves cannot be used where single wiring has been specified.) Note 3) This also includes the number of blanking plate assembly.
Nil
2 4
3 5
P, E port entry U side (2 to 10 stations) P, E port entry D side (2 to 10 stations) P, E port entry both sides (2 to 24 stations)
U D B
C Note) E Note)
G H J
For built-in silencer type, P and E ports are available on the U and D sides. 3/5(E) port is plugged. The silencer discharge port is located on the opposite side of P, E port entry. (Example: When the P, E port entry is D side, the silencer discharge port is U side.) When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids. Note) When ordering the SUP/EXH block assembly with the built-in silencer, the P port will be located on either the U or D side.
SY3000
8 5/16"
SY5000
10 3/8"
PE X 3/5E
N
U side
D side
PWR OUT
0 4 5 2
1 3 BUS IN 1P PCI
2B 2B 2B 2B 2B
1P
Mounting
Nil
BUS OUT
Valve stations
D D0 D3 D24
SS5Y3-12S6Q42-05B 1 set (Type 12 5-station manifold base part no.) SY3130-5U1-C6 3 sets (2-position single part no.) SY3230-5U1-C6 2 sets (2-position double part no.) EX600-DXPD 1 set I/O Unit part number (Station 1) EX600-DYPB 1 set I/O Unit part number (Station 2) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the valve, etc. The valve arrangement is numbered as the 1st station from the D side. Under the manifold part number, state the valves to be mounted, then the I/O Units in order from the 1st station as shown in the figure above. If the arrangement becomes complicated, specify on a manifold specification sheet. Note) Do not enter the SI Unit part number and the End Plate part number together.
Direct mounting DIN rail mounting (With DIN rail) DIN rail mounting (Without DIN rail) For 3 stations Specify a longer rail than the standard length. For 24 stations
When it is necessary to mount a DIN rail without an SI unit, select D0 and order the DIN rail with required length separately by referring to L3 in the dimensions. When selecting the DIN rail mounting (with DIN rail) of the SY5000 series with the End Plate to a power supply 7/8 inch connector, 9 I/O Unit stations will result in a total of 23 valve stations. With 24 stations, the DIN rail mounting (with DIN rail) cannot be indicated, so please exercise caution. (Refer to DIN Rail Overall Length on pages 19 to 22.)
Refer to the catalog of each series for details on manifold solenoid valve specifications, Common Precautions and Specific Product Precautions.
23
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SY3000/5000
How
SY 3 1 3 0
Top mounted Series
3 5
SY3000 SY5000
1 C6
A, B port size
Thread piping
Symbol
B K
Standard (102 psi) Quick response type (102 psi) High pressure type (145 psi)
Type of actuation
1 2 3 4 5 A B C
2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.)
Only metal seal type is available for the high pressure type.
M5 01
Symbol
Port size M5 x 0.8 1/8 A, B port 2 One-touch fitting 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting A, B port
SY3000 SY5000
Coil type
Nil
Only rubber seal type is available for 4-position dual 3-port valves.
Be sure to select the power saving circuit type when the valve is continuously energized for long periods of time. The product with power saving circuit is not available for the quick response type.
C2 C3 C4 C6 C8
Symbol
b b b b
b b b
SY3000 SY5000
Seal type
0 1
Rubber seal Metal seal
Rated voltage
5
24 VDC
N1 1/8" One-touch fitting N3 5/32" One-touch fitting N7 1/4" One-touch fitting N9 5/16" One-touch fitting
b b b
b b b
Pilot type
Nil
Thread type
Internal pilot External pilot
Nil
F N T
Rc G NPT NPTF
None Built-in
Only rubber seal type. Manifold installed type is available if the back pressure check valve is required for a valve with metal seal. Refer to the SY3000/5000 series catalog (CAT.ES11-103) for details. However, it is not recommended to use the built-in valve type and the manifold installed type at the same time because it will reduce the flow. The built-in valve type back pressure check valve is not available for the 3-position type.
Only Z and NZ types are available for the product with power saving circuit. Select a valve from R, U, S or Z when the SI Unit common is positive common. Select a valve from R, U, NS or NZ when the SI Unit common is negative common.
B K H
With mounting screw (Round head combination screw) With mounting screw (Hexagon socket head cap screw) With mounting screw (Round head combination screw, falling-out-prevention type) With mounting screw (Hexagon socket head cap screw, falling-out-prevention type)
Manual override
Nil: Non-locking push type D: Push-turn locking slotted type F: Slide locking type
For K and H, mounting screws do not fall out from the valve. (An apparatus to prevent falling-out is provided on the valve port block.) When ordering a valve individually, the base gasket is not included. Since the base gasket is attached to the manifold, please order the base gasket separately if it is needed for maintenance service. Refer to the SY3000/5000 series catalog (CAT.ES11-103) for details. B and H cannot be selected for the individual SUP/EXH spacer assembly.
24
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
RoHS
Series SV1000/2000/3000
When I/O Unit EX600-DE or EX600-DF are selected, enclosure is IP40. Refer to page 50 for details.
How
rder Manifold
b Tie-rod Base
SS5V 1
Series
1 2 3 0 Q N V ZE D
SV1000 SV2000 SV3000
10S6 Q
Enclosure
Nil
D 05 U
Nil
C6
Mounting
D D0 Note 1) D3 D20
Direct mounting DIN rail mounting (With DIN rail) DIN rail mounting (Without DIN rail) For 3 stations When a longer DIN rail is desired For 20 stations length.)
IP40 IP67
SI Unit
Without SI Unit For DeviceNet For PROFIBUS DP For CC-Link For EtherNet/IP For EtherCAT
than the specified stations. (Specify a longer rail than the standard
When Without SI Unit is specified, I/O Unit cannot be mounted. When Without SI Unit is specified, Valve Plate to connect the valve manifold and SI Unit is not mounted. Refer to page 51 for mounting method.
2 3
No End Plate Power supply with M12 connector (Max. supplied current 2 A) Power supply with 7/8 inch connector (Max. supplied current 8 A)
SI Unit common
Nil
Note 1) In the case of D0, only DIN rail mounting bracket is attached. Note 2) DIN rail is not attached (but shipped together) on the manifold in the case of with DIN rail. Refer to the SV series catalog for mounting method. Note 3) When selecting the DIN rail mounting (with DIN rail) of the SV3000 series, and 9 I/O Unit stations will result in a total of 18 valve stations. With 19 and 20 stations, the DIN rail mounting (with DIN rail) cannot be indicated, so please exercise caution. (Refer to DIN Rail Overall Length on page 31 and 32.) Note 4) Please consult SMC when changing from direct mounting to DIN rail mounting. Note 5) When it is necessary to mount a DIN rail without an SI Unit, select D0 and order the DIN rail with required length separately by referring to L1 in the dimensions.
1 9
Symbol Stations 2 stations
Note 1) Without SI Unit, the symbol is nil. None Note 2) SI Unit is not included in I/O Unit stations. 1 station Note 3) When I/O Unit is selected, it is shipped separately
9 stations
and assembled by customer. Refer to the attached operation manual for mounting method.
S Note) Internal pilot, Built-in silencer External pilot R RS Note) External pilot, Built-in silencer
Note) When the built-in silencer type is used, keep the exhaust port from coming in direct contact with water or other liquids.
Valve stations
Note Double wiring Note 1)
02 16 02 20
Note 1) Double wiring: single, double, 3-position and 4-position valves can be used on all manifold stations. Use of a single solenoid will result in an unused control signal. If this is not desired, order with a specified layout. Note 2) Specified layout: Indicate the wiring specifications on the manifold specification sheet. (Note that double, 3-position and 4-position valves cannot be used where single wiring has been specified.)
P, E port entry
U D B
U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 20 stations)
C3 C4 C6 C4 C6 C8 C6 C8 C10 M
A, B port 3.2 One-touch fitting 4 One-touch fitting 6 One-touch fitting 4 One-touch fitting 6 One-touch fitting 8 One-touch fitting 6 One-touch fitting 8 One-touch fitting 10 One-touch fitting A, B port mixed
10 One-touch fitting
SV2000
12 One-touch fitting
SV3000
N1 N3 N7 N3 N7 N9 N7 N9 N11 M
A, B port 1/8" One-touch fitting 5/32" One-touch fitting 1/4" One-touch fitting 5/32" One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting 1/4" One-touch fitting 5/16" One-touch fitting 3/8" One-touch fitting A, B port mixed
SV2000
SV3000
In the case of mixed specifications (M), indicate separately on the mani fold specification sheet. The X and PE port size of External pilot type (R), and X port size of External pilot, Built-in silencer type (RS) are 4 (mm) or 5/32" (inch) for the SV1000/2000 series, and 6 (mm) or 1/4" (inch) for the SV3000 series.
25
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series SV
1 2 3 4 5
Serial transmission kit SS5V1-W10S6Q2N2D-05B-C6 1 set SV1100-5FU 3 sets SV1200-5FU 2 sets EX600-DXPD 1 set EX600-DYPB 1 set
Manifold base part number Valve part number (Stations 1 to 3) Valve part number (Stations 4 to 5) I/O Unit part number (Station 1) I/O Unit part number (Station 2)
Enter in order starting from the first station on the D side. If the arrangement becomes complicated, specify on a manifold specification sheet. Enter in order starting from the first station on the D side. If the arrangement becomes complicated, specify on a manifold specification sheet. Note) Do not enter the SI Unit part number and the End Plate part number together.
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
SV 1 1 0 0
Series
1 2 3
SV1000 SV2000 SV3000
5FU
Made to Order
Nil
X90
Type of actuation
1 2 3 4 5 A B C
2-position single 2-position double 3-position closed center 3-position exhaust center 3-position pressure center 4-position dual 3-port valve (N.C./N.C.) 4-position dual 3-port valve (N.O./N.O.) 4-position dual 3-port valve (N.C./N.O.)
Manual override
Nil: Non-locking push type
4-position dual 3-port valves are applicable to the SV1000/2000 series only.
Pilot type
Nil
External pilot specification is not available for 4-position dual 3-port valves.
Rated voltage
5
24 VDC
None Built-in
The built-in back pressure check valve type is applicable to the SV1000 series only. The product with back pressure check valve is not available for 3-position valves.
Refer to the catalog of each series for details on manifold solenoid valve specifications, Common Precautions and Specific Product Precautions.
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
A B
For the I/O Unit part number mounted, refer to the following pages. Digital Input Unit P .1 Digital Output Unit P .1 Digital Input/Output Unit P .1 Analog Input Unit P .2 Analog Output Unit P .2 Analog Input/Output Unit P .2
D side
U side
Valve stations
Fluororubber specification
D: Push-turn locking
slotted type
26
Series SV
Dimensions: Series SV1000
Power supply with M12 connector
Manual override Press and turn for the locking type 4(A) port side: Orange 2(B) port side: Green Marker groove (mm)
L4
47 8
L5 L3
54.2
5.5
106
35
90
39.9
A A
29.6 83 10.8 DIN rail holding screw (For DIN rail mounting) (4.9) 92.6 U side
FE terminal DIN rail holding screw (For DIN rail mounting) 2 x 4.6 (For mounting) 5.5
L7 L2
(Rail mounting hole pitch: 12.5)
L6
5
L1
D side
One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 3.2, 1/8" 4, 5/32" 6, 1/4"
(Station 1) (Station n)
(3.2)
Input connector
Output connector
SI Unit
B 2
B 2
B 2
B 2
A 4
A 4
A 4
A 4
8.6
10
23
3/5
3/5
24.6
45.5
18.3
L2 = L1 10.5 L3 = 10.5 x n1 + 53 L4 = L3 + 81 + 47 x n2 L5 = (L1 L4)/2 L6 = 10.5 x n1 + 42 L7 = 47 x n2 + 81
18.3
2
185.5 235.5 273 323 373 423 460.5 510.5 560.5 610.5
3
198 248 285.5 335.5 385.5 435.5 473 523 573 623
4
210.5 248 298 348 398 435.5 485.5 535.5 585.5 623
5
210.5 260.5 310.5 360.5 398 448 498 548 598 635.5
6
223 273 323 373 410.5 460.5 510.5 560.5 598 648
7
235.5 285.5 335.5 373 423 473 523 560.5 610.5 660.5
8
248 298 335.5 385.5 435.5 485.5 535.5 573 623 673
9
260.5 310.5 348 398 448 498 535.5 585.5 635.5 685.5
10
273 310.5 360.5 410.5 460.5 498 548 598 648 685.5
11
273 323 373 423 473 510.5 560.5 610.5 660.5 698
12
285.5 335.5 385.5 435.5 473 523 573 623 660.5 710.5
13
298 348 398 435.5 485.5 535.5 585.5 623 673 723
14
310.5 360.5 410.5 448 498 548 598 635.5 685.5 735.5
15
323 373 410.5 460.5 510.5 560.5 598 648 698 748
16
335.5 373 423 473 523 560.5 610.5 660.5 710.5 760.5
17
348 385.5 435.5 485.5 535.5 573 623 673 723 760.5
7.5
18
348 398 448 498 535.5 585.5 635.5 685.5 723 773
59.5
0 1 2 3 4 5 6 7 8 9
27
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
A B
19
360.5 410.5 460.5 498 548 598 648 698 735.5 785.5
20
373 423 473 510.5 560.5 610.5 660.5 698 748 798
Series SV
(mm)
L4
47 8
L5 L3
54.2
5.5
106
35
90
39.9
A A
29.6 10.8 DIN rail holding screw (For DIN rail mounting) (4.9) 92.6 U side 83
FE terminal DIN rail holding screw (For DIN rail mounting) 2 x 4.6 (For mounting) 5.5 Digital Input Unit
L7 L2
(Rail mounting hole pitch: 12.5)
L6
5
L1
D side
One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 3.2, 1/8" 4, 5/32" 6, 1/4"
(3.2)
Power connector
Input connector
Output connector
SI Unit
(Station 1)
(Station n)
56.6
B 2
B 2
B 2
B 2
A 4
A 4
A 4
A 4
8.6
10
7.5
23
3/5
3/5
24.6
45.5
18.3
L2 = L1 10.5 L3 = 10.5 x n1 + 53 L4 = L3 + 97.5 + 47 x n2 L5 = (L1 L4)/2 L6 = 10.5 x n1 + 42 L7 = 47 x n2 + 81
18.3
2
198 248 298 348 385.5 435.5 485.5 535.5 573 623
3
210.5 260.5 310.5 348 398 448 498 535.5 585.5 635.5
4
223 273 310.5 360.5 410.5 460.5 498 548 598 648
5
235.5 285.5 323 373 423 473 510.5 560.5 610.5 660.5
6
248 285.5 335.5 385.5 435.5 473 523 573 623 660.5
7
248 298 348 398 435.5 485.5 535.5 585.5 635.5 673
8
260.5 310.5 360.5 410.5 448 498 548 598 635.5 685.5
9
273 323 373 410.5 460.5 510.5 560.5 598 648 698
10
285.5 335.5 373 423 473 523 573 610.5 660.5 710.5
11
298 348 385.5 435.5 485.5 535.5 573 623 673 723
12
310.5 348 398 448 498 535.5 585.5 635.5 685.5 723
13
310.5 360.5 410.5 460.5 510.5 548 598 648 698 735.5
14
323 373 423 473 510.5 560.5 610.5 660.5 698 748
15
335.5 385.5 435.5 473 523 573 623 660.5 710.5 760.5
16
348 398 448 485.5 535.5 585.5 635.5 673 723 773
17
360.5 410.5 448 498 548 598 635.5 685.5 735.5 785.5
18
373 410.5 460.5 510.5 560.5 598 648 698 748 798
59.5
0 1 2 3 4 5 6 7 8 9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
A B
19
385.5 423 473 523 573 610.5 660.5 710.5 760.5 798
20
385.5 435.5 485.5 535.5 573 623 673 723 760.5 810.5
28
Series SV
Dimensions: Series SV2000
Power supply with M12 connector
Manual override Press and turn for the locking type 4(A) port side: Orange 2(B) port side: Green (mm)
Marker groove
L4
47 8
L5 L3
54.2
5.5
29.6
A A
106
90
35
FE terminal DIN rail holding screw (For DIN rail mounting) 2 x 4.6 (For mounting) 5.5
Valve Plate
Communication connector
(4.9)
Input connector
L7 L2
(Rail mounting hole pitch: 12.5)
L6
6 5
L1
D side
One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 4, 5/32" 6, 1/4" 8, 5/16"
(Station 1) (Station n)
One-touch fitting [1(P), 3/5(E) port] Applicable tube O.D.: 10, 3/8"
2 B
2 B
2 B
2 B
2 3/5
4 A
4 A
4 A
4 A
2
198 248 298 348 385.5 435.5 485.5 535.5 573 623
3
223 260.5 310.5 360.5 410.5 448 498 548 598 635.5
4
235.5 285.5 323 373 423 473 510.5 560.5 610.5 660.5
5
248 298 348 385.5 435.5 485.5 535.5 585.5 623 673
6
260.5 310.5 360.5 410.5 460.5 498 548 598 648 685.5
7
285.5 335.5 373 423 473 523 560.5 610.5 660.5 710.5
8
298 348 398 435.5 485.5 535.5 585.5 623 673 723
9
310.5 360.5 410.5 460.5 498 548 598 648 685.5 735.5
10
335.5 373 423 473 523 560.5 610.5 660.5 710.5 748
11
348 398 435.5 485.5 535.5 585.5 623 673 723 773
12
360.5 410.5 460.5 498 548 598 648 685.5 735.5 785.5
13
373 423 473 523 560.5 610.5 660.5 710.5 760.5 798
14
398 435.5 485.5 535.5 585.5 635.5 673 723 773 823
15
410.5 460.5 510.5 548 598 648 698 735.5 785.5 835.5
16
423 473 523 573 610.5 660.5 710.5 760.5 798 848
17
448 485.5 535.5 585.5 635.5 673 723 773 823 860.5
18
460.5 510.5 548 598 648 698 735.5 785.5 835.5 885.5
19
473 523 573 610.5 660.5 710.5 760.5 798 848 898
0 1 2 3 4 5 6 7 8 9
29
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
20.5
11.9
12
7.5
25.2
3/5
30.6
52.5
63.5
115.5
12.2
20
485.5 535.5 585.5 635.5 673 723 773 823 860.5 910.5
Series SV
(mm)
L4
47 8
L5 L3
54.2
5.5
29.6
A A
106
90
35
Power connector FE terminal DIN rail holding screw (For DIN rail mounting) 2 x 4.6 (For mounting) 5.5
Communication connector
(4.9)
L7 L2
(Rail mounting hole pitch: 12.5)
L6
6 5
L1
D side
One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 4, 5/32" 6, 1/4" 8, 5/16"
U side One-touch fitting [1(P), 3/5(E) port] Applicable tube O.D.: 10, 3/8"
(Station 1)
(Station n)
56.6
2 B
2 B
2 B
2 B
4 A
4 A
4 A
4 A
12
7.5
2
223 260.5 310.5 360.5 410.5 448 498 548 598 648
3
235.5 285.5 323 373 423 473 523 560.5 610.5 660.5
4
248 298 348 398 435.5 485.5 535.5 585.5 623 673
5
273 310.5 360.5 410.5 460.5 498 548 598 648 685.5
6
285.5 335.5 373 423 473 523 560.5 610.5 660.5 710.5
7
298 348 398 435.5 485.5 535.5 585.5 623 673 723
8
310.5 360.5 410.5 460.5 498 548 598 648 685.5 735.5
9
335.5 373 423 473 523 560.5 610.5 660.5 710.5 748
10
348 398 435.5 485.5 535.5 585.5 623 673 723 773
11
360.5 410.5 460.5 498 548 598 648 698 735.5 785.5
12
373 423 473 523 573 610.5 660.5 710.5 760.5 798
13
398 448 485.5 535.5 585.5 635.5 673 723 773 823
14
410.5 460.5 510.5 548 598 648 698 735.5 785.5 835.5
15
423 473 523 573 610.5 660.5 710.5 760.5 798 848
16
448 485.5 535.5 585.5 635.5 673 723 773 823 860.5
17
460.5 510.5 548 598 648 698 735.5 785.5 835.5 885.5
18
473 523 573 610.5 660.5 710.5 760.5 798 848 898
19
485.5 535.5 585.5 635.5 673 723 773 823 873 910.5
0 1 2 3 4 5 6 7 8 9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
20.5
11.9
25.2
3/5
3/5
30.6
52.5
63.5
115.5
12.2
20
510.5 548 598 648 698 748 785.5 835.5 885.5 935.5
30
Series SV
Dimensions: Series SV3000
Power supply with M12 connector
Manual override Press and turn for the locking type 4(A) port side: Orange 2(B) port side: Green (mm)
Marker groove 47
L4
8
L5 L3
54.2 35 5.5
8
A A
29.6 47.2 5 DIN rail holding screw (For DIN rail mounting) U side One-touch fitting [1(P), 3/5(E) port] Applicable tube O.D.: 12, 3/8"
2 4 E 3/5
FE terminal DIN rail holding screw (For DIN rail mounting) 2 x 4.6 (For mounting) 5.5
Input connector
L7 L2
(Rail mounting hole pitch: 12.5)
L6
L1
D side
One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 6, 1/4" 8, 5/16" 10, 3/8"
(Station 1)
(5.3)
(Station n)
2 B
2 B
2 B
2 B
3/5 A
4 A
4 A
4 A
4 A
25
(Pitch) P = 20.5
21.3 23.5
2
223 273 310.5 360.5 410.5 460.5 498 548 598 648
3
248 285.5 335.5 385.5 435.5 473 523 573 623 660.5
4
260.5 310.5 360.5 398 448 498 548 598 635.5 685.5
5
285.5 335.5 373 423 473 523 560.5 610.5 660.5 710.5
6
298 348 398 448 498 535.5 585.5 635.5 685.5 723
7
323 373 423 460.5 510.5 560.5 610.5 648 698 748
8
348 398 435.5 485.5 535.5 585.5 623 673 723 773
9
360.5 410.5 460.5 510.5 548 598 648 698 735.5 785.5
10
385.5 435.5 485.5 523 573 623 673 710.5 760.5 810.5
11
410.5 448 498 548 598 635.5 685.5 735.5 785.5 835.5
12
423 473 523 573 610.5 660.5 710.5 760.5 798 848
13
448 498 535.5 585.5 635.5 685.5 735.5 773 823 873
14
473 510.5 560.5 610.5 660.5 698 748 798 848 885.5
15
485.5 535.5 585.5 635.5 673 723 773 823 860.5 910.5
16
510.5 560.5 598 648 698 748 785.5 835.5 885.5 935.5
17
535.5 573 623 673 723 760.5 810.5 860.5 910.5 948
18
548 598 648 685.5 735.5 785.5 835.5 873 923 973
19
573 623 660.5 710.5 760.5 810.5 848 898 948
20
585.5 635.5 685.5 735.5 773 823 873 923 973
0 1 2 3 4 5 6 7 8 9
31
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
12
10 11.6 13.5
(5.1)
SI Unit Output Connector for connector Handheld Terminal Digital Input Unit Digital Output Unit
83.8 128.8
106 90
14.3
5
B B A
Series SV
(mm)
Marker groove
L4
47 8
L5 L3
54.2 35 5.5
8
A A
29.6 47.2 5 DIN rail holding screw (For DIN rail mounting) U side One-touch fitting [1(P), 3/5(E) port] Applicable tube O.D.: 12, 3/8"
2 4 E 3/5
Power connector FE terminal DIN rail holding screw (For DIN rail mounting) 2 x 4.6 (For mounting)
Input connector
Output connector
SI Unit Connector for Handheld Terminal Digital Output Unit Valve Plate Communication connector
L7 L2
(Rail mounting hole pitch: 12.5)
L6
L1
D side
One-touch fitting [4(A), 2(B) port] Applicable tube O.D.: 6, 1/4" 8, 5/16" 10, 3/8"
(Station 1)
(5.3)
(Station n)
2 B
2 B
2 B
2 B
3/5 A
4 A
4 A
4 A
4 A
25
(Pitch) P = 20.5
21.3 23.5
2
235.5 285.5 335.5 385.5 423 473 523 573 610.5 660.5
3
260.5 310.5 348 398 448 498 535.5 585.5 635.5 685.5
4
285.5 323 373 423 473 510.5 560.5 610.5 660.5 698
5
298 348 398 435.5 485.5 535.5 585.5 623 673 723
6
323 373 410.5 460.5 510.5 560.5 598 648 698 748
7
335.5 385.5 435.5 485.5 523 573 623 673 723 760.5
8
360.5 410.5 460.5 498 548 598 648 685.5 735.5 785.5
9
385.5 423 473 523 573 623 660.5 710.5 760.5 810.5
10
398 448 498 548 585.5 635.5 685.5 735.5 773 823
11
423 473 523 560.5 610.5 660.5 710.5 748 798 848
12
448 485.5 535.5 585.5 635.5 673 723 773 823 860.5
13
460.5 510.5 560.5 610.5 648 698 748 798 835.5 885.5
14
485.5 535.5 573 623 673 723 760.5 810.5 860.5 910.5
15
510.5 548 598 648 698 735.5 785.5 835.5 885.5 923
16
523 573 623 660.5 710.5 760.5 810.5 860.5 898 948
17
548 598 635.5 685.5 735.5 785.5 823 873 923 973
18
560.5 610.5 660.5 710.5 760.5 798 848 898 948 985.5
19
585.5 635.5 685.5 723 773 823 873 910.5 960.5
0 1 2 3 4 5 6 7 8 9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
12
10 11.6 13.5
71.3
(5.1)
83.8 128.8
106 90
14.3
5
B B A
20
32
RoHS
Series S0700
How to Order Manifold
SS0750 08 C4 SD6Q 2 N 1
Stations
Symbol
B
Option
01
Stations 1 station
24 Note) 24 stations
Note) Max. number of stations depends on the wiring specifications.
C2 C3 C4 CM N1 N3 NM
Port size With 2 One-touch fitting With 3.2 One-touch fitting With 4 One-touch fitting Mixed sizes and with port plug Note) With 1/8" One-touch fitting With 5/32" One-touch fitting Mixed sizes and with port plug Note)
Symbol Option None Nil B Note 2) With back pressure check valve (All stations) With DIN rail (Rail length: Standard) D Without DIN rail (with bracket) D0 D Note 3) With DIN rail (Rail length specified, : Stations) K Note 4) Special wiring specifications (Except double wiring) With name plate N External pilot R Built-in silencer S
Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BKN Note 2) When the back pressure check valve is used only for specified station, specify the back pressure check valve part number, and specify the station number to which the valve is mounted, on the manifold specification sheet. Note 3) Specified station number shall be longer than manifold station number. Note 4) When single wiring and double wiring are mixed, specify wiring type of each station on the manifold specification sheet.
Metric
Inch
Note) Indicate the sizes on the manifold specification sheet in the case of CM and NM.
Kit type
Kit type Symbol Specifications Stations Max. number of Max. number stations for special of solenoids wiring specifications
Note 5) When Without SI Unit (SD60) is specified, With DIN rail (D) cannot be selected.
S kit
SD60 Without SI Unit SD6Q For DeviceNet SD6N For PROFIBUS DP 1 to 12 stations SD6V For CC-Link SD6ZE For EtherNet/IP SD6D For EtherCAT
1
24 stations 24
Note) Max. number of stations depends on the number of solenoids. Add the option symbol -K when the combination of single wiring and double wiring is specified. When Without SI Unit is specified, Valve Plate to connect the manifold and SI Unit is not mounted. Refer to page 51 for mounting method. When Without SI Unit is specified, I/O Unit cannot be mounted.
Note 1) Without SI Unit, the symbol is nil. Note 2) SI Unit is not included in I/O Unit stations. Note 3) When I/O Unit is selected, it is shipped separately and assembled by customer. Refer to the attached operation manual for mounting method.
SI Unit common
Type of actuation Number of solenoids Single type 1 Double, dual 3-port type 2
Nil
2 3
No End Plate Power supply with M12 connector (Max. supplied current 2 A) Power supply with 7/8 inch connector (Max. supplied current 8 A)
Refer to the catalog of each series for details on manifold solenoid valve specifications, Common Precautions and Specific Product Precautions.
33
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series S0700
Digital Input Unit EX600-DXPD Digital Output Unit EX600-DYPB SI Unit Note) EX600-SDN1A
D side For the I/O Unit part number mounted, refer to the following pages. Digital Input Unit P.1 Digital Output Unit P.1 Digital Input/Output Unit P.1 Analog Input Unit P.2 Analog Output Unit P.2 Analog Input/Output Unit P.2
12 12 12 12
Serial transmission kit SS0750-08C4SD6Q2N2 1 set Manifold base part number S0710-5 3 sets Valve part number (Stations 1 to 3) S0720-5 4 sets Valve part number (Stations 4 to 7) SS0700-10A-1 1 set Blanking plate part number (Station 8) EX600-DXPD 1 set I/O Unit part number (Station 1) EX600-DYPB 1 set I/O Unit part number (Station 2)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Enter in order starting from the first station on the D side. If the arrangement becomes complicated, specify on a manifold specification sheet. Enter in order starting from the first station on the D side. If the arrangement becomes complicated, specify on a manifold specification sheet. Note) Do not enter the SI Unit part number and the End Plate part number together.
S07 1 0
Type of actuation
2-position single
(A)(B) 4 2
5
Coil voltage
5
24 VDC
1
5 1 3 (R1) (P) (R2)
4 (A) 5 (R1)
2 (B)
Function
Specification Symbol Standard Nil External pilot Note) R
Note) Not applicable for dual 3-port valves
1 (P)
3 (R2)
2-position double
(A)(B) 4 2
2
5 1 3 (R1) (P) (R2)
4 (A) 5 (R1)
2 (B)
1 (P)
3 (R2)
4 (A) 5 (R1)
2 (B)
1 (P)
3 (R2)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
14
14
14
14
14
14
14
U side
Valve stations
34
Series S0700
Dimensions
Power supply with M12 connector
L1
(5.25) 5.5 26 Power connector Marker groove Indicator light (mm)
L6
(n1) x 8.5 8.5 Manual override 1.5
4.4 12.8
(5.5) (35) 62
14 12 14 12
106
90
(51.8)
12
12
12
Valve Plate FE terminal 2 x M4 mounting hole End Plate Input connector SI Unit Digital Output Unit Output connector Digital Input Unit Communication connector Connector for Handheld Terminal
L3
L5
C8, N9: 3(R) port C8: 8 One-touch fitting N9: 5/16" One-touch fitting D side Station 30 8
1 2 3 4 5 6 7 8 n U side
11.5
56.6
(12)
(7.5)
C8, N9: 1(P) port C8: 8 One-touch fitting N9: 5/16" One-touch fitting DIN rail clamping screw
8.5
17.2
2n x C2, C3, C4, N1, N3 <4(A), 2(B) port> C2: 2 One-touch fitting C3: 3.2 One-touch fitting C4: 4 One-touch fitting N1: 1/8" One-touch fitting N3: 5/32" One-touch fitting
17.5
6.5
9.6
4 (mm)
1
173 223
10
11
12
13
14
15
16
17
18
19
20
21
22
72
0 1 2 3 4 5 6 7 8 9
260.5 260.5 273 298 348 310.5 323 360.5 373 448
285.5 285.5 298 323 373 335.5 348 385.5 398 473 523
310.5 310.5 323 360.5 360.5 373 398 410.5 423 498 548
260.5 273 310.5 323 360.5 373 448 498 548 598
285.5 285.5 298 335.5 335.5 348 373 385.5 398 473 523
460.5 460.5 473 510.5 510.5 523 548 560.5 573 648
35
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
14
14
14
14
14
14
23
24
485.5 485.5 498 535.5 535.5 548 573 585.5 598 673 723
Series S0700
(mm)
Dimensions
Power supply with 7/8 inch connector
L1
(5.25) 5.5 Power connector 26 Marker groove Indicator light
L6
(n 1) x 8.5 8.5 Manual override 1.5
4.4 12.8
(5.5) (35) 62
14 12 14 12
106
90
(51.8)
12
12
12
Valve Plate FE terminal 2 x M4 mounting hole End Plate Input connector SI Unit Digital Output Unit Output connector Digital Input Unit Communication connector Connector for Handheld Terminal
L3
L5
C8, N9: 3(R) port C8: 8 One-touch fitting N9: 5/16" One-touch fitting 11.5 D side Station 8
1 2 3 4 5 6 7 8 n U side
DIN rail clamping screw 56.6 33.6 (7.5) C8, N9: 1(P) port C8: 8 One-touch fitting N9: 5/16" One-touch fitting 8.5 17.2 2n x C2, C3, C4, N1, N3 <4(A), 2(B) port> C2: 2 One-touch fitting C3: 3.2 One-touch fitting C4: 4 One-touch fitting N1: 1/8" One-touch fitting N3: 5/32" One-touch fitting DIN rail clamping screw 17.5 (mm) 6.5 60
(12)
10
11
12
13
14
15
16
17
18
19
20
21
22
9.6
23
72
0 1 2 3 4 5 6 7 8 9
285.5 285.5 298 323 373 335.5 348 385.5 398 473
310.5 310.5 323 348 398 360.5 373 410.5 423 498 548
335.5 335.5 348 385.5 385.5 398 423 435.5 448 523 573
310.5 310.5 323 360.5 360.5 373 398 410.5 423 498 548
485.5 485.5 498 535.5 535.5 548 573 585.5 598 673
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
14
14
14
14
14
14
24
385.5 435.5 473
510.5 510.5 523 560.5 560.5 573 598 610.5 623 660.5 660.5 698 748 710.5 760.5 810.5
36
RoHS
Series VQC1000
How to Order Manifold
VV5QC 1 1 08 C6 SD6Q 2 N 1
Series VQC1000 Option Base mounted plug-in Stations
Symbol Nil None With back pressure check valve (All stations) With DIN rail (Rail length: Standard) Without DIN rail (with bracket) With DIN rail (Rail length specified, : Stations) Special wiring specifications (Except double wiring) With name plate External pilot Built-in silencer, Direct exhaust
01 24 Note)
Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS Note 2) When the back pressure check valve is used only for specified station, specify the back pressure check valve part number, and specify the station number to which the valve is mounted, on the manifold specification sheet. Note 3) Specified station number shall be longer than manifold station number. Note 4) When single wiring and double wiring are mixed, specify wiring type of each station on the manifold specification sheet. Note 5) When the external pilot type is selected, also specify the external pilot type for valves. Note 6) Built-in silencer type dose not satisfy IP67. Note 7) When specification change from no DIN rail type to DIN rail mounting type, please consult SMC. Note 8) When "Without SI Unit (SD60)" is specified, With DIN rail (D) cannot be selected. Note 9) DIN rail is not attached (but shipped together) on the manifold in the case of with DIN rail. Refer to the VQC series catalog (CAT.ES11101) for mounting method.
Note 1) Indicate the sizes on the manifold specification sheet in the case of CM and LM. Note 2) Symbols for inch size are as follows. N1: 1/8" N3: 5/32" N7: 1/4" NM: Mixed sizes The top ported elbow is LN and the bottom ported elbow is BN. For NM, specify it on the manifold specification sheet.
1 9
Kit type
Kit type Symbol Specifications Stations Max. number of stations for special wiring specifications Max. number of solenoids
Note 1) Without SI Unit, the symbol is nil. Note 2) SI Unit is not included in I/O Unit stations. Note 3) When I/O Unit is selected, it is shipped separately and assembled by customer. Refer to the attached operation manual for mounting method. Note 4) Refer to page 50 for details on enclosure.
S kit
SD60 Without SI Unit SD6Q For DeviceNet SD6N For PROFIBUS DP SD6V For CC-Link SD6ZE For EtherNet/IP SD6D For EtherCAT
1 to 12 stations
24 stations
24
SI Unit common
Nil
Note) Max. number of stations depends on the number of solenoids. Add the option symbol -K when the combination of single wiring and double wiring is specified. When Without SI Unit is specified, I/O Unit cannot be mounted. When Without SI Unit is specified, Valve Plate to connect the manifold and SI Unit is not mounted. Refer to page 51 for mounting method.
Refer to the catalog of each series for details on manifold solenoid valve specifications, Common Precautions and Specific Product Precautions.
2 3
No End Plate Power supply with M12 connector (Max. supplied current 2 A) Power supply with 7/8 inch connector (Max. supplied current 8 A)
37
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VQC1000
For the I/O Unit part number mounted, refer to the following pages. Digital Input Unit P.1 Digital Output Unit P.1 Digital Input/Output Unit P.1 Analog Input Unit P.2 Analog Output Unit P.2 Analog Input/Output Unit P.2
D side
Serial transmission kit VV5QC11-08C6SD6Q2N2 1 set Manifold base part number VQC1100N-51 2 sets Valve part number (Stations 1 to 2) VQC1200N-51 5 sets Valve part number (Stations 3 to 7) VVQ1000-10A-1 1 set Blanking plate part number (Station 8) EX600-DXPD 1 set I/O Unit part number (Station 1) EX600-DYPB 1 set I/O Unit part number (Station 2)
The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.
Enter in order starting from the first station on the D side. If the arrangement becomes complicated, specify on a manifold specification sheet. Enter in order starting from the first station on the D side. If the arrangement becomes complicated, specify on a manifold specification sheet. Note) Do not enter the SI Unit part number and the End Plate part number together.
VQC 1 1 0 0
Series VQC1000 Type of actuation
2-position single (A) (B) 4 2 4-position dual 3-port valve (A) (B) (A) 4 2 Note)
5
5
1
Manual override
Nil: Non-locking push type (Tool required)
A B
Coil voltage
24 VDC
1
5 1 3 (R1) (P) (R2) 2-position double (Metal) (A) (B) 4 2
A
5 (R1)
N.C.
1 (P)
3 (R2)
Function
Nil
N.C.
B
5 1 3 (R1) (P) (R2) 5 (R1)
N.O.
1 (P)
3 (R2)
Standard (0.4 W) Quick response type (0.95 W) High pressure type (145 psi) Negative common External pilot
N.O.
Note)
C
5 1 3 (R1) (P) (R2) 3-position closed center (A) (B) 4 2
N.C.
1 (P)
N.O.
Note 1) When two or more symbols are specified, indicate them alphabetically. However, combination of B and K is not possible. Note 2) Only metal seal type Note 3) When negative common is specified for the SI Unit, select and mount the valve of negative common. Note 4) Not applicable for dual 3-port valves
3
5 1 3 (R1) (P) (R2) 3-position exhaust center (A) (B) 4 2
Seal type
0 1
Metal seal Rubber seal
4
5 1 3 (R1) (P) (R2) 3-position pressure center (A) (B) 4 2
5
5 1 3 (R1) (P) (R2)
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
B: Locking type
(Tool required)
A B
C: Locking type
(Manual)
38
Series VQC1000
Dimensions
Power supply with M12 connector
(5.25) 5.5 26 (mm)
L6
28 P = 10.5 1.5 Indicator light Manual override
(12)
85
Power connector
106
71
90
66 (5.5) (35) (40) Valve Plate Connector for Handheld Terminal Output connector SI Unit Digital Input Unit Input connector
(51.8)
75 40.5
17.5
4 x M4 mounting hole
L3
Digital Output Unit
L5
1 2 3 4 5 6 7 8
n U side
C8 [3(R) EXH port] C8: 8 One-touch fitting DIN rail clamping screw 8
R R
11.5
2 18.5 25
56.6
3 X 12 P 1A
B B B B B B B B
3 X 12 P 1
7.5
(12)
7.5
C3, C4, C6, M5 [4(A), 2(B) port] C3: 3.2 One-touch fitting C4: 4 One-touch fitting C6: 6 One-touch fitting M5: M5 thread C8 [1(P) SUP port] C8: 8 One-touch fitting 20.5 P = 10.5 34
1
198
2
198
10
11
12
13
14
15
16
17
18
19
20
21
398
9.5
22
23
24
435.5 485.5 523
0 1 2 3 4 5 6 7 8 9
260.5 260.5 273 298 310.5 323 360.5 373 410.5 423
235.5 248 285.5 298 335.5 348 423 473 523 573
360.5 360.5 373 410.5 423 460.5 473 510.5 523 548
460.5 460.5 473 510.5 523 560.5 573 610.5 623 648
360.5 360.5 373 410.5 423 460.5 473 510.5 523 548
560.5 560.5 573 610.5 623 660.5 673 710.5 710.5 748 760.5 810.5 860.5
585.5 585.5 598 635.5 648 685.5 698 735.5 748 773
485.5 485.5 498 535.5 548 585.5 598 635.5 648 673
610.5 623
685.5 698
39
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
63.5
Series VQC1000
(mm)
Dimensions
Power supply with 7/8 inch connector
(5.25) 5.5 26 (12)
L6
28 P = 10.5 1.5 Indicator light Manual override
106
71
90
66 (5.5) (35) (40) Valve Plate Connector for Handheld Terminal Output connector Digital Input Unit Input connector SI Unit
(51.8)
75 40.5
17.5
4 x M4 mounting hole
L3
Digital Output Unit
L5
1 2 3 4 5 6 7 8
U side C8 [3(R) EXH port] C8: 8 One-touch fitting DIN rail clamping screw
11.5
2 18.5 25
56.6
3 X 12 P 1A
B B B B B B B B
3 X 12 P 1
(7.5)
(12)
C3, C4, C6, M5 [4(A), 2(B) port] C3: 3.2 One-touch fitting C4: 4 One-touch fitting C6: 6 One-touch fitting M5: M5 thread C8 [1(P) SUP port] C8: 8 One-touch fitting 20.5 P = 10.5 34
10
298
11
12
13
14
15
16
17
373
18
19
20
7.5
21
9.5
22
23
24
0 1 2 3 4 5 6 7 8 9
235.5 235.5 248 273 285.5 298 335.5 348 385.5 398 423
285.5 298
435.5 435.5 448 485.5 498 535.5 548 585.5 598 623 635.5 685.5 735.5 785.5
335.5 335.5 348 385.5 398 435.5 448 485.5 498 523
460.5 460.5 473 510.5 523 560.5 573 610.5 623 648
560.5 560.5 573 610.5 623 660.5 673 710.5 723 748
460.5 460.5 473 510.5 523 560.5 573 610.5 623 648
660.5 673
40
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
63.5
RoHS
Series VQC2000
How to Order Manifold
VV5QC 2 1 08 C8 SD6Q 2 N 1
Series VQC2000 Option Base mounted plug-in Stations
Symbol Nil None With back pressure check valve (All stations) With DIN rail (Rail length: Standard) Without DIN rail (with bracket) With DIN rail (Rail length specified, : Stations) Special wiring specifications (Except double wiring) With name plate External pilot Built-in silencer, Direct exhaust P and R ports included on both sides of the U side
01 24 Note)
Note 1) Indicate the sizes on the manifold specification sheet in the case of CM and LM. Note 2) Symbols for inch size are as follows. N3: 5/32" N7: 1/4" N9: 5/16" NM: Mixed sizes The top ported elbow is LN and the bottom ported elbow is BN. For NM, specify it on the manifold specification sheet.
Kit type
Kit type Symbol Specifications Stations Max. number of stations for special wiring specifications Max. number of solenoids
Note 1) When two or more symbols are specified, indicate them alphabetically. Example) -BRS Note 2) When the back pressure check valve is used only for specified station, specify the back pressure check valve part number, and specify the station number to which the valve is mounted, on the manifold specification sheet. Note 3) When selecting the DIN rail mounting (with DIN rail) of the VQC2000 series with the End Plate to a power supply 7/8 inch connector, 9 I/O Unit stations will result in a total of 23 valve stations. With 24 stations, the DIN rail mounting (with DIN rail) cannot be indicated, so please exercise caution. (Refer to DIN Rail Overall Length on page 44.) Note 4) Specified station number shall be longer than manifold station number. Note 5) When single wiring and double wiring are mixed, specify wiring type of each station on the manifold specification sheet. Note 6) When the external pilot type is selected, also specify the external pilot type for valves. Note 7) Built-in silencer type does not satisfy IP67. Note 8) 2 ports for SUP and EXH are included on both sides of U side (cylinder port and coil side) with 12 one-touch fittings. Note 9) When specification change from no DIN rail type to DIN rail mounting type, please consult SMC. Note 10) When Without SI Unit (SD60) is specified, With DIN rail (D) cannot be selected. Note 11) DIN rail is not attached (but shipped together) on the manifold in the case of with DIN rail. Refer to the VQC series catalog (CAT.ES11-101) for mounting method.
S kit
Without SI Unit SD60 SD6Q For DeviceNet SD6N For PROFIBUS DP SD6V For CC-Link SD6ZE For EtherNet/IP SD6D For EtherCAT
1
1 to 12 stations 24 stations 24
Note 1) Without SI Unit, the symbol is nil. Note 2) SI Unit is not included in I/O Unit stations. Note 3) When I/O Unit is selected, it is shipped separately and assembled by customer. Refer to the attached operation manual for mounting method. Note 4) Refer to page 50 for details on enclosure.
Note) Max. number of stations depends on the number of solenoids. Add the option symbol -K when the combination of single wiring and double wiring is specified. When Without SI Unit is specified, I/O Unit cannot be mounted. When Without SI Unit is specified, Valve Plate to connect the manifold and SI Unit is not mounted. Refer to back page 51 for mounting method.
SI Unit common
Nil
2 3
No End Plate Power supply with M12 connector (Max. supplied current 2 A) Power supply with 7/8 inch connector (Max. supplied current 8 A)
41
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VQC2000
VQC 2 1 0 0
Series VQC2000 Type of actuation
2-position single (A) (B) 4 2 4-position dual 3-port valve (A) (B) (A) 4 2 Note)
1
Manual override
Nil: Non-locking push type (Tool required)
1
5 1 3 (R1) (P)(R2) 2-position double (Metal) (A) (B) 4 2
A
5 (R1)
N.C.
1 (P)
3 (R2)
N.C.
B: Locking type
(Tool required)
Note)
B
5 1 3 (R1) (P)(R2)
N.O.
1 (P)
N.O.
Note)
C: Locking type
(Manual)
C
5 1 3 (R1) (P)(R2) 3-position closed center (A) (B) 4 2
N.C.
1 (P)
N.O.
3
5 1 3 (R1) (P) (R2) 3-position exhaust center (A) (B) 4 2
Seal type
0 1
Metal seal Rubber seal
4
5 1 3 (R1) (P) (R2) 3-position pressure center (A) (B) 4 2
Function
Nil
5
5 1 3 (R1) (P) (R2)
Standard (0.4 W) Quick response type (0.95 W) High pressure type (145 psi) Negative common External pilot
Note 1) When two or more symbols are specified, indicate them alphabetically. However, combination of B and K is not possible. Note 2) Only metal seal type Note 3) When negative common is specified for SI Unit, select and mount the valve of negative common. Note 4) Not applicable for dual 3-port valves
Coil voltage
5
24 VDC
Refer to the catalog of each series for details on manifold solenoid valve specifications, Common Precautions and Specific Product Precautions.
42
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VQC2000
Dimensions
Power supply with M12 connector
(5.25) 5.5 26 (12) 85 74 Power connector (mm)
L6
38.5 1 Indicator light Manual override
(51.8)
17.5
3.5
(53.5)
(5.5)
(35)
105.5 49.5
106
71
90
80
FE terminal 2 x M4 mounting hole End Plate Input connector Digital Input Unit Output connector D side Station DIN rail clamping screw 30 C10 [3(R) EXH port] C10: 10 One-touch fitting 11.5 8
R
L3
Valve Plate SI Unit Connector for Handheld Terminal Digital Output Unit
L5
4 x M5 mounting hole
C10 [3(R) EXH port] (Double sided type: C12) C10: 10 One-touch fitting (C12: 12 One-touch fitting)
1 2 3 4 5 6 7 8 n
56.6
12 X
3
B B B B B B B B
3 X 12
P 1
A A A A A A A A
(12)
(7.5)
C10 [1(P) SUP port] C10: 10 One-touch fitting C4, C6, C8 [4(A), 2(B) port] C4: 4 One-touch fitting C6: 6 One-touch fitting C8: 8 One-touch fitting
25 P = 16 45
C10 [1(P) SUP port] (Double sided type: C12) C10: 10 One-touch fitting (C12: 12 One-touch fitting)
13.5
10
25
30 798
(mm)
8
323
10
11
373
12
13
14
15
16
17
18
19
498 548
20
21
22
548
23
24
0 1 2 3 4 5 6 7 8 9
43
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
76.5
5.5
120
Series VQC2000
(mm)
Dimensions
Power supply with 7/8 inch connector
(5.25) 5.5 26 (12) 74
L6
38.5 P = 16 0.9 1 Indicator light Manual override
(51.8)
17.5
3.5
(5.5)
(35)
(53.5)
105.5 49.5
106
71
90
80
Power connector FE terminal 2 x M4 mounting hole End Plate Input connector Digital Input Unit Valve Plate SI Unit Connector for Handheld Terminal Digital Output Unit Output connector D side Station DIN rail clamping screw 11.5 C10 [3(R) EXH port] C10: 10 One-touch fitting 8
R
L3
L5
4 x M5 mounting hole
C10 [3(R) EXH port] (Double sided type: C12) C10: 10 One-touch fitting (C12: 12 One-touch fitting)
1 2 3 4 5 6 7 8 n
56.6
12 X
B B B B B B B B
3 X 12
P 1
A A A A A A A A
10
(12)
(7.5)
C10 [1(P) SUP port] C10: 10 One-touch fitting C4, C6, C8 [4(A), 2(B) port] C4: 4 One-touch fitting C6: 6 One-touch fitting C8: 8 One-touch fitting
25 P = 16 45
C10 [1(P) SUP port] (Double sided type: C12) C10: 10 One-touch fitting (C12: 12 One-touch fitting)
13.5
25
30
(mm)
1
223 273 323
7
323
10
373
11
12
13
14
15
16
17
18
19
20
21
548
22
23
24
585.5 635.5 685.5 735.5 785.5 823 873 923 973
0 1 2 3 4 5 6 7 8 9
335.5 348
360.5 385.5 398 410.5 423 460.5 473 510.5 523 548 598 648 573
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
76.5
5.5
120
44
RoHS
Series VQC4000
How to Order Manifold
VV5QC 4 1 16 02
Series VQC4000 Base mounted plug-in Stations
Symbol
SD6Q 2 N 1
Option
Nil
K Note)
Stations 1 station
01
Note) When single wiring and double wiring are mixed, specify wiring type of each station on the manifold specification sheet.
16 Note) 16 stations
Note) Max. number of stations depends on the wiring specifications.
1 9
Note 2) SI Unit is not included in I/O Unit stations. Note 3) When I/O Unit is selected, it is shipped separately and assembled by customer. Refer to the attached operation manual for mounting method. Note 4) Refer to page 50 for details on enclosure.
Thread type
Nil
F T
Rc G NPT/NPTF
SI Unit common
Nil
Kit type
Kit type Symbol Specifications Max. number of Max. number Stations stations for special of solenoids wiring specifications Nil 16 stations 24
S kit
SD60 Without SI Unit SD6Q For DeviceNet SD6N For PROFIBUS DP 1 to 12 stations SD6V For CC-Link SD6ZE For EtherNet/IP SD6D For EtherCAT
Note) Max. number of stations depends on the number of solenoids. Add the option symbol -K when the combination of single wiring and double wiring is specified. When Without SI Unit is specified, I/O Unit cannot be mounted. When Without SI Unit is specified, Valve Plate to connect the manifold and SI Unit is not mounted. Refer to page 51 for mounting method.
Refer to the catalog of each series for details on manifold solenoid valve specifications, Common Precautions and Specific Product Precautions.
45
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VQC4000
VQC 4 1 0 0
Series VQC4000 Type of actuation
2-position single (A) (B) 4 2
5
Manual override
Nil: Non-locking push type (Tool required)
1
5 1 3 (R1) (P) (R2) 2-position double (Metal) (A) (B) 4 2
B: Locking type
(Tool required)
3
5 1 3 (R1) (P) (R2) 3-position exhaust center (A) (B) 4 2
4
5 1 3 (R1) (P) (R2) 3-position pressure center (A) (B) 4 2
Coil voltage
5
24 VDC
5
5 1 3 (R1) (P) (R2) 3-position double check (A) (B) 4 2
Function
Nil
6
5 1 3 (R1) (P) (R2)
R Y Note 2)
Note 1) When two or more symbols are specified, indicate them alphabetically. Note 2) Suitable for continuously energizing for long periods of time.
Seal type
0 1
Metal seal Rubber seal
46
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series VQC4000
Dimensions
Power supply with M12 connector
L2
5.5 Digital Input Unit Input connector Power connector FE terminal 9 47 m + 86 Output connector Digital Output Unit Communication connector SI Unit (n 1) x 25 Indicator light Manual override 25 65.5 6.5 (mm)
L1
(163)
106
78.5
D side Station 3/4 [3(R) port] 3/4: 3/4" female thread (Rc, G, NPT/NPTF) 1/2 [1(P) port] 1/2: 1/2" female thread (Rc, G, NPT/NPTF) 30
R4
26
47 m
47
Valve Plate
U side
10
.5
163
90
11.5
56.6
20.6
1/8 (External pilot port) 1/8: 1/8" female thread (Rc, G, NPT/NPTF)
11.5
1/8 (Pilot EXH port) 1/8: 1/8" female thread (Rc, G, NPT/NPTF)
1/4, 3/8, C8, C10, C12 [4(A), 2(B) port] 1/4: 1/4" female thread (Rc, G, NPT/NPTF) 3/8: 3/8" female thread (Rc, G, NPT/NPTF) C8: 8 One-touch fitting C10: 10 One-touch fitting C12: 12 One-touch fitting
Formulas L1 = 25n + 106 L2 = 25n + 184 L2 is the dimension without I/O Unit. Add 47 mm for each additional I/O Unit s. m is number of I/O Units.
Dimensions
L n
1
131 209
2
156 234
3
181 259
4
206 284
5
231 309
6
256 334
7
281 359
8
306 384
9
331 409
10
356 434
11
381 459
12
406 484
13
431 509
14
456 534
15
481 559
16
506 584
L1 L2
47
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
42.7
43.5
77.3
72
101.2
15.7
95.5
Series VQC4000
(mm)
Dimensions
Power supply with 7/8 inch connector
16.5 5.5 47 m + 86 Communication connector Digital Output Unit Output connector SI Unit
L2 L1
(n 1) x 25 Indicator light Manual override 25 65.5 6.5
(163)
.5
3/4 [3(R) port] 3/4: 3/4" female thread (Rc, G, NPT/NPTF) 1/2 [1(P) port] 1/2: 1/2" female thread (Rc, G, NPT/NPTF) 11.5
R4
26
47 m
47
Valve Plate
U side
10
163
90
56.6
20.6
11.5
1/8 (External pilot port) 1/8: 1/8" female thread (Rc, G, NPT/NPTF)
1/8 (Pilot EXH port) 1/8: 1/8" female thread (Rc, G, NPT/NPTF)
1/4, 3/8, C8, C10, C12 [4(A), 2(B) port] 1/4: 1/4" female thread (Rc, G, NPT/NPTF) 3/8: 3/8" female thread (Rc, G, NPT/NPTF) C8: 8 One-touch fitting C10: 10 One-touch fitting C12: 12 One-touch fitting
Formulas L1 = 25n + 106 L2 = 25n + 184 L2 is the dimension without I/O Unit. Add 47 mm for each additional I/O Unit s. m is number of I/O Units.
Dimensions
L n
1
131 209
2
156 234
3
181 259
4
206 284
5
231 309
6
256 334
7
281 359
8
306 384
9
331 409
10
356 434
11
381 459
12
406 484
13
431 509
14
456 534
15
481 559
16
506 584
L1 L2
42.7
43.5
77.3
72
48
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
101.2
15.7
95.5
Series EX600
Design/Selection
Mounting
Warning
1. Use this product within the specification range.
Using beyond the specified specifications range can cause fire, malfunction, or damage to the system. Check the specifications before operation.
Caution
2. Do not drop, bump, or apply excessive impact.
Otherwise, the unit can become damaged, malfunction, or fail to function.
2. When using for an interlock circuit: Provide a multiple interlock system which is operated by another system (such as mechanical protection function). Perform an inspection to confirm that it is working properly.
This may cause possible injury due to malfunction.
4. When lifting a large size manifold solenoid valve unit, take care to avoid causing stress to the valve connection joint.
The connection parts of the unit may be damaged. Because the unit may be heavy, carrying and installation should be performed by more than one operator to avoid strain or injury.
Caution
1. When applicable to UL, use a Class 2 power supply unit conforming to UL1310 for direct current power supply. 2. Use this product within the specified voltage range.
Using beyond the specified voltage range is likely to cause the units and connecting devices to be damaged or to malfunction.
3. The power supply for the unit should be 0 V as the standard for both power supply for output as well as power supply for control/input.
+24 V Power supply for output 0V Power supply for control/input +24 V Power supply for control/input 24 V Power supply for output 0V +24 V
Wiring
Caution
1. Check the grounding to maintain the safety of the reduced wiring system and for anti-noise performance.
Provide a specific grounding as close to the unit as possible to minimize the distance to grounding.
2. Avoid repeatedly bending or stretching the cable and applying a heavy object or force to it.
Wiring applying repeated bending and tensile stress to the cable can break the circuit.
3. Avoid miswiring.
If miswired, there is a danger of malfunction or damage to the reduced wiring system.
5. Avoid wiring the power line and high pressure line in parallel.
Noise or surge produced by signal line resulting from the power line or high pressure line could cause malfunction. Wiring of the reduced wiring system or input/output device and the power line or high pressure line should be separated from each other.
Mounting
Caution
1. When handling and assembling units: Do not touch the sharp metal parts of the connector or plug. Do not apply excessive force to the unit when disassembling.
The connecting portions of the unit are firmly joined with seals.
When joining units, take care not to get fingers caught between units.
49
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
Wiring
Operating Environment
Caution
7. When a reduced wiring system is installed in machinery/equipment, provide adequate protection against noise by using noise filters, etc.
Noise in signal lines may cause malfunction.
Caution
3. Do not use in an environment where oil and chemicals are used.
Operating in environments with coolants, cleaning solvents, various oils or chemicals may cause adverse effects (damage, malfunction) to the unit even in a short period of time.
8. When connecting wires of input/output device or Handheld Terminal, prevent water, solvent or oil from entering inside from the connecter section.
This can cause damage, equipment failure or malfunction.
4. Do not use in an environment where the product could be exposed to corrosive gas or liquid.
This may damage the unit and cause it to malfunction.
Operating Environment
Warning
1. Do not use in an atmosphere containing an inflammable gas or explosive gas.
Use in such an atmosphere is likely to cause a fire or explosion. This system is not explosion-proof.
6. Use the product type that has an integrated surge absorption element when directly driving a load which generates surge voltage by relay, solenoid valves or lamp.
When a surge generating load is directly driven, the unit may be damaged.
Caution
1. Select the proper type of enclosure according to the environment of operation.
IP65/67 is achieved when the following conditions are met. 1) Provide appropriate wiring between all units using electrical wiring cables, communication connectors and cables with M12 connectors. 2) Suitable mounting of each unit and manifold valve. 3) Be sure to mount a seal cap on any unused connectors. If using in an environment that is exposed to water splashes, please take measures such as using a cover. When the enclosure is IP40, do not use in an operating environment or atmosphere where it may come in contact with corrosive gas, chemical agents, seawater, water, or water vapor. When connected to the EX600-DE or EX600DF, manifold enclosure is IP40. Also, the Handheld Terminal conforms to IP20, so prevent foreign matter from entering inside, and water, solvent or oil from coming in direct contact with it.
7. The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes in your system. 8. Keep dust, wire scraps and other extraneous material from getting inside the product.
This may cause malfunction or damage.
10. Do not use in places where there are cyclic temperature changes.
In case that the cyclic temperature is beyond normal temperature changes, the internal unit is likely to be adversely effected.
12. Use this product within the specified ambient temperature range.
This may cause malfunction.
13. Do not use in places where there is radiated heat around it.
Such a place is likely to cause malfunction.
50
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Series EX600
Adjustment/Operation
Maintenance
Warning
1. Do not perform operation or setting with wet hands.
There is a risk of electrical shock.
Warning
1. Do not disassemble, modify (including circuit board replacement) or repair this product.
Such actions are likely to cause injuries or breakage.
3. The forced input/output function is used to change the signal status forcibly. When operating this function, be sure to check the safety of the surroundings and installation.
Otherwise, injury or equipment damage could result.
2. When an inspection is performed, Turn off the power supply. Stop the air supply, exhaust the residual pressure in piping and verify that the air is released before performing maintenance work.
Unexpected malfunction of system components and injury can result.
4. Incorrect setting of parameters can cause malfunction. Be sure to check the settings before use.
This may cause injury or equipment damage.
Caution
1. When handling and replacing the unit: Do not touch the sharp metal parts of the connector or plug. Do not apply excessive force to the unit when disassembling.
The connecting portions of the unit are firmly joined with seals.
Caution
1. Use a watchmakers screwdriver with thin blade for the setting of each switch of the SI Unit. When setting the switch, do not touch other unrelated parts.
This may cause parts damage or malfunction due to a short circuit.
When joining units, take care not to get fingers caught between units.
Injury can result.
3. For details on programming and address setting, refer to the manual from the PLC manufacturer.
The content of programming related to protocol is designed by the manufacturer of the PLC used.
<Handheld Terminal> 4. Do not press the setting buttons with a sharp pointed object.
This may cause damage or malfunction.
Other
Caution
1. Refer to the catalog of each series for Common Precautions and Specific Product Precautions on manifold solenoid valves.
Valve Plate
Trademark
DeviceNet is a trademark of ODVA. EtherNet/IP is a trademark of ODVA. EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany.
51
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Safety Instructions
These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger. They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)1), and other safety regulations.
1) ISO 4414: Pneumatic fluid power General rules relating to systems. ISO 4413: Hydraulic fluid power General rules relating to systems. IEC 60204-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) ISO 10218-1: Manipulating industrial robots - Safety. etc.
Warning
1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment.
Caution
1. The product is provided for use in manufacturing industries.
The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch.
2. Only personnel with appropriate training should operate machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced.
product
and
1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions.
1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation.
Compliance Requirements
1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited. 2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulations of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed.
Revision history
Edition B EtherNet/IP communication protocol added. Analog Output Unit and Input/Output Unit added. D-sub connector and spring type terminal block added. Applicable solenoid valve SY3000/5000 series added. Number of pages decreased from 64 to 60. Edition C EtherCAT communication protocol added. OW PX
Safety
Be sure to read Handling Precautions for SMC Products (M-E03-3) before using.
52
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Asia/Oceania
SRI LANKA (Distributor) Electro-Serv(Pvt.)Ltd. IRAN (Distributor) Abzarchian Co. Ltd. U.A.E. (Distributor) Machinery People Trading Co. L.L.C. KUWAIT (Distributor) Esco Kuwait Equip & Petroleum App. Est. SAUDI ARABIA (Distributor) Assaggaff Trading Est. BAHRAIN (Distributor) Mohammed Jalal & Sons W.L.L. Technical & Automative Services SYRIA (Distributor) Miak Corporation JORDAN (Distributor) Atafawok Trading Est. BANGLADESH (Distributor) Chemie International AUSTRALIA SMC Pneumatics(Australia)Pty.Ltd. NEW ZEALAND SMC Pneumatics(N.Z.)Ltd. JAPAN SMC Corporation
Europe/Africa
CZECH REPUBLIC SMC Industrial Automation CZ s.r.o. HUNGARY SMC Hungary Ipari Automatizlsi Kft. POLAND SMC Industrial Automation Polska Sp. z o.o. SLOVAKIA SMC Priemyseln Automatizcia Spol s.r.o. SLOVENIA SMC Industrijska Avtomatika d.o.o. BULGARIA SMC Industrial Automation Bulgaria EOOD CROATIA SMC Industrijska Automatika d.o.o. BOSNIA AND HERZEGOVINA(Distributor) A.M. Pneumatik d.o.o. SERBIA(Distributor) Best Pneumatics d.o.o. UKRAINE(Distributor) PNEUMOTEC Corp. FINLAND SMC Pneumatics Finland Oy NORWAY SMC Pneumatics Norway AS SWEDEN SMC Pneumatics Sweden AB ESTONIA SMC Pneumatics Estonia O LATVIA SMC Pneumatics Latvia SIA LITHUANIA(LIETUVA) UAB SMC Pneumatics ROMANIA SMC Romania S.r.l. RUSSIA SMC Pneumatik LLC. KAZAKHSTAN SMC Kazakhstan, LLC. TURKEY (Distributor) Entek Pnmatik Sanayi ve. Ticaret S irketi MOROCCO (Distributor) Soraflex TUNISIA (Distributor) Byms EGYPT (Distributor) Saadani Trading & Industrial Services NIGERIA (Distributor) Faraday Engineering Company Ltd. SOUTH AFRICA (Distributor) Hyflo Southern Africa (Pty.) Ltd.
Asia/Oceania
CHINA SMC(China)Co.,Ltd. CHINA SMC Pneumatics (Guangzhou) Ltd. HONG KONG SMC Pneumatics(Hong Kong)Ltd. TAIWAN SMC Pneumatics(Taiwan)Co.,Ltd. KOREA SMC Pneumatics Korea Co., Ltd. SINGAPORE SMC Pneumatics(S.E.A.)Pte.Ltd. MALAYSIA SMC Pneumatics(S.E.A.)Sdn.Bhd. THAILAND SMC (Thailand) Ltd. PHILIPPINES Shoketsu SMC Corporation INDIA SMC Pneumatics(India)Pvt.Ltd. ISRAEL (Distributor) Baccara Geva A.C.S. Ltd. INDONESIA (Distributor) PT. Sinar Mutiara Cemerlang VIETNAM (Distributor) Dy Dan Trading Co.,Ltd. PAKISTAN (Distributor) Jubilee Corporation
Europe/Africa
GERMANY SMC Pneumatik GmbH SWITZERLAND SMC Pneumatik AG U.K. SMC Pneumatics (U.K.) Ltd. FRANCE SMC Pneumatique SA SPAIN / PORTUGAL SMC Espaa S.A. ITALY SMC Italia S.p.A. GREECE SMC HELLAS E.P.E IRELAND SMC Pneumatics (Ireland) Ltd. NETHERLANDS (Associated company) SMC Pneumatics BV BELGIUM (Associated company) SMC Pneumatics N.V./S.A. DENMARK SMC Pneumatik A/S AUSTRIA SMC Pneumatik GmbH (Austria)
Chicago Cincinnati Cleveland Detroit Indianapolis Milwaukee Minneapolis St. Louis Toronto Windsor
Atlanta Birmingham Boston Charlotte Nashville New Jersey Richmond Rochester Tampa Montreal
Vancouver
Toronto Detroit
Montreal
Boston Chicago
Livermore
Indianapolis
Atlanta
PY-10M-RRD