Vous êtes sur la page 1sur 6

Applicator Sizing - Flow

Project :
Customer: Contact person: Phone: eMail: C.Project No.: Fax:

TAG : --Timestamp: Sales order number: --Review number: ---

Sizing Sheet
General Parameters
Fluid State Character Abrasivity Fluid Group (PED) Steam, superheated -MODIFIEDSteam Superheated Clean Not abrasive Normal Fluid (Fluid group 2) Atmospheric Pressure Standard 1.0132 bar_a EN/DIN/ISO

Operating Conditions
minimum Requested Flow Pressure Temperature Density Viscosity Sound Velocity Pressure (min/max) Temp. (min/max) 15 250 10 nominal 20 25 310 10 0.02047 571.6 25 310 maximum 20 ton_metric/h bar_a C kg/m3 cP m/s bar_a C

Flowmeter : Prowirl 72F


Flow Principle Meter Size Minimum Flow Maximum Flow Material (sensor) * Process connection* PED category ** : Vortex (Prowirl) DN 150 1.34 ton_metric/h 72.621 ton_metric/h SS 1.4408 / CF3M PN 40 EN 1092-1 B1 / 1.4404/316L Flange Application is Cat. II

Extended order code


Qty 1 Item Flowmeter Prowirl 72F Description 72F1F-SE***P Extended order code

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ** The PED category is an Endress+Hauser recommendation and depends on the fluid category, process data as well from the max. permissible pressure of the selected pressure rating.The fluids of the Applicator data base are classified to 67/548/EWG.

Print date: 07.10.2013 11:44 PM Applicator: 10.16.02 / 127

-1/6-

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - Flow


Project :
Customer: Contact person: Phone: eMail: C.Project No.: Fax:

TAG : --Timestamp: Sales order number: --Review number: ---

Sizing Sheet
Sizing and Calculated Results
Requested Flow Pressure loss Velocity (meas. tube) Measured error Vol.*** Reynolds No. Frequency minimum 10 18.5 16.52 1 1 181 120 103.1 nominal 20 74 33.05 1 2 362 240 206.3 maximum 20 74 33.05 1 2 362 240 206.3 Hz ton_metric/h mbar m/s %

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.

Print date: 07.10.2013 11:44 PM Applicator: 10.16.02 / 127

-2/6-

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - Flow


Project :
Customer: Contact person: Phone: eMail: C.Project No.: Fax:

TAG : --Timestamp: Sales order number: --Review number: ---

Fluid properties sheet


Fluid
Fluid name Steam, superheated -MODIFIED State Calculation standard Steam Superheated IAPWS

Fluid description
Medium character Fluid group (PED) Fluid stability Tc (Critical temperature) Pc (Critical pressure) Clean Normal Fluid (Fluid group 2) Stable 374 C 221.2 bar Tm (Melting point) Tb (Boiling point) Kappa -0.01 C 117.8 C 1.29

Calculated results
Density nominal Viscosity nom. Sound velocity nom. Vapor pressure nom. 10 kg/m3 0.02047 cP 571.6 m/s 98.647 bar_a 1.0132 bar_a Pressure nominal Temperature nom. 25 bar_a 310 C

Reference values: Normal conditions (SI):


Atmospheric pressure

Standard conditions (US):


Atmospheric pressure

1.0132 bar_a

Print date: 07.10.2013 11:44 PM Applicator: 10.16.02 / 127

-3/6-

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - Flow


Project :
Customer: Contact person: Phone: eMail: C.Project No.: Fax:

TAG : --Timestamp: Sales order number: --Review number: ---

Tri-Size Sheet
General Parameters
Fluid State Character Abrasivity Fluid Group (PED) Steam, superheated -MODIFIEDSteam Superheated Clean Not abrasive Normal Fluid (Fluid group 2) Next Smaller Size Prowirl 72F Vortex (Prowirl) DN 100 PN 40 EN 1092-1 B1 / 1.4404/316L 0.589 31.924 0.589 95 380 380 37.59 75.18 75.18 1 2 2 3 562 843 707.8 Atmospheric Pressure Standard 1.0132 bar_a EN/DIN/ISO

Sizing and Calculated Results


Flow meter Flow Principle Meter Size Process connection* Minimum Flow Maximum Flow Linear Flow Pressure loss at req. Flow min. Pressure loss at req. Flow nom. Pressure loss at req. Flow max. Velocity (meas. tube) at req. Flow min. Velocity (meas. tube) at req. Flow nom. Velocity (meas. tube) at req. Flow max. Meas. error Vol. at req. Flow min.*** Meas. error Vol. at req. Flow nom.*** Meas. error Vol. at req. Flow max.*** Reynolds No. Frequency

Current Size Prowirl 72F Vortex (Prowirl) DN 150 PN 40 EN 1092-1 B1 / 1.4404/316L 1.34 72.621 1.34 18.5 74 74 16.52 33.05 33.05 1 1 1 2 362 240 206.3

Next Bigger Size Prowirl 72F Vortex (Prowirl) DN 200 PN 40 EN 1092-1 B1 / 1.4404/316L 2.572 139.406 2.572 6.49 25.99 25.99 8.608 17.22 17.22 1 1 1 1 704 962 77.6 ton_metric/ h ton_metric/ h ton_metric/ h mbar mbar mbar m/s m/s m/s % % %

*The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. ***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.

Print date: 07.10.2013 11:44 PM Applicator: 10.16.02 / 127

-4/6-

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - Flow


Project :
Customer: Contact person: Phone: eMail: C.Project No.: Fax:

TAG : --Timestamp: Sales order number: --Review number: ---

Chart Sheet
Flowmeter : Prowirl 72F
Flow Principle Meter Size Minimum Flow Maximum Flow Vortex (Prowirl) DN 150 1.34 ton_metric/h 72.621 ton_metric/h

***For error calculation, the specified reference conditions for the calibration of the flowmeter according to ISO/IEC 17025 apply. Further information in technical documentation.

Print date: 07.10.2013 11:44 PM Applicator: 10.16.02 / 127

-5/6-

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Applicator Sizing - Flow


Project :
Customer: Contact person: Phone: eMail: C.Project No.: Fax:

TAG : --Timestamp: Sales order number: --Review number: ---

Corrosion Information
General Parameters
Fluid State Character Steam, superheated -MODIFIEDSteam Superheated Clean Abrasivity Flow Principle Not abrasive Vortex (Prowirl)

Interpretation of Data, (M) Material:


A: B: C: NR: U: resistant, unsufficent resistant, not resistant, not recommended unknown 0.05 mm/y (0.002 inches/y) 0.5 mm/y (0.02 inches/y) 1.3 mm/y (0.05 inches/y)

Interpretation of Data, (P) Plastics:


A: B: C: NR: U: Material (Sensor) * resistant, unsufficent resistant, not resistant, not recommended unknown Temperature minimum250C nominal : 310C maximum : 310C *The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Endress+Hauser makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above. 15% vol. Swelling/y; 30% vol. Swelling/y; 50% vol. Swelling/y; 15% Loss of Tensile Strength/y 30% Loss of Tensile Strength/y 60% Loss of Tensile Strength/y

Print date: 07.10.2013 11:44 PM Applicator: 10.16.02 / 127

-6/6-

Under no circumstances is Endress+Hauser liable for errors, neither in the Software and in its documentation, nor for any errors and consequential damage which may arise out of their use. The results in Applicator apply to parameters entered by the user. A change in these parameters could lead to different results. Mandatory data are in the according technical information (TI).

Vous aimerez peut-être aussi