Académique Documents
Professionnel Documents
Culture Documents
Company History
1991 Establishment of Seojin Industry Co.,Ltd.
2006 Won the 30 million USD Export Tower Award granted by the Ministry of Knowledge Economy
2006 Earned recognition by Hyundai Mipo Dockyard Co., Ltd. as one of the excellent suppliers.
2007 Won the 70 million USD Export Tower Award granted by the Ministry of Knowledge Economy
2007 Received the High quality supplier Certification from DSME
2007 Achieved Korean world-class product award 2007
2008 Won the 100 million USD Export Tower Award granted by the Ministry of Knowledge Economy
2008 OHSAS 18001 Certification by LRQA (for Health, Safety and Environment)
2009 Awarded the Q-Mark as a Silver grade for Offshore Cable supplier by Samsung Heavy Industries
2010 Awarded the Best Supplier for Offshore & Marine Cable by Ocean Rig
2010 Earned recognition by DSME as one of the excellent supplier
2011
2011
Awarded the Best Supplier for Offshore & Marine Cable by Stena Sphere
KEPIC Certification by KEA (Manufacture of Class 1E cable)
2012 Won the 200 million USD Export Tower Award granted by the Ministry of Knowledge Economy
Certificates
Type Approval Certification for shipboard cables : ABS, BV, CCS, DNV, GL, KR, LR, NK and RINA
Type Approval Certification for NEK 606(2004) offshore cables : ABS, DNV and LR
Type Approval Certification by ABS for offshore cables and listed on ETL
Type Approval Certification for Passenger ships cables : ABS, DNV,LR, BV and CCS
Obtained Patent of Paint Resistant Shipboard Cables (Patent N0. 10-0627241)
Type Approval Certification for IEEE1580 Type P cables : ABS and DNV and listed on ETL
Type Approval Certification for LNG Carrier cables : ABS, DNV, LR and BV
Gost-R Certification for NEK 606(2004) offshore cables by GOSSTANDART
Type Approval Certification for Marine Optical Fiber Cables : ABS and DNV
Code Designation
Materials
Insulation
Bedding / inner
covering inner sheath
Armor / screen
No armour
Outer sheath
Added abbreviation
(i)
Individual screen
(c)
Collective screen
( i&c)
Example
0.6/1kV BFOU
Voltage
Fire resisting layer + insulation(HF EPR)
Inner covering(HFC)
Armor(Copper)
Sheath(SHF2 or SHF mud)
Index
Designation
Page
Flame retardant
06 ~ 09
Flame retardant
Fire resistance
Flame retardant
Instrumentation &
Communication cable
3.6/6kV RFOU
P2
P2/P9
6/10kV RFOU
P3
P3/P10
P4/P11
0.6/1kV RU
11 ~ 14
8.7/15kV RFOU
P4
15 ~ 18
0.6/1kV RFOU
P1
P1/P8
0.6/1kV BU
19 ~ 22
0.6/1kV BFOU
P5
P5/P12
23 ~ 26
0.6/1kV RU
P18
28 ~ 36
0.6/1kV BU
P17
37 ~ 39
0.6/1kV UX
P15
40 ~ 42
250V RFOU(i)
S1
S1/S5
43 ~ 45
250V RFOU(c)
S2
S2/S6
46 ~ 54
250V BFOU(i)
S3
S3/S7
55 ~ 57
250V BFOU(c)
S4
S4/S8
58 ~ 60
250V RU(i)
S11
S12
Designation
61 ~ 63
250V RU(c)
Flame retardant
65 ~ 66
250V BU(i)
S13
Flame retardant
68 ~ 69
250V BU(c)
S14
Fire resistance
70 ~ 71
Note.
73 ~ 93
HV Power Cable
06 ~ 09
HV Power Cable
Application Standard
- Design guide
- Flame retardant
6/10kV RFOU
- Halogen content
- Mud resistant
: UL 1581
Construction
Sectional view
Classification
Code
Construction detail
Conductor
Conductor screen
Insulation
Insulation screen
Cabling
Inner covering
Armor
Sheath
Core identification
Note. Flexible cable (Class5 Conductor) can be supplied
06
Offshore Cable
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C)
U
HV Power Cable
EA
mm
mm
mm
mm
Dia. of
wire for
armour
mm
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
mm
Conductor
Resistance
(at 20)
(Max.)
Test
Voltage
Cable
Weight
mm
/km
V/5min.
kg/km
10
4.2
2.5
0.3
1.0
15.7
0.3
1.5
21.0
1.1
1.840
12.5
740
16
5.3
2.5
0.3
1.0
16.7
0.3
1.6
22.2
1.2
1.160
12.5
850
25
6.6
2.5
0.3
1.0
18.0
0.3
1.6
23.5
1.2
0.734
12.5
1,000
35
7.9
2.5
0.3
1.0
19.2
0.3
1.7
24.9
1.3
0.529
12.5
1,160
50
19
9.1
2.5
0.3
1.0
20.5
0.3
1.7
26.2
1.3
0.391
12.5
1,340
70
19
11.0
2.5
0.3
1.0
22.3
0.3
1.8
28.2
1.4
0.270
12.5
1,630
95
19
12.9
2.5
0.3
1.0
24.2
0.3
1.9
30.3
1.5
0.195
12.5
1,980
120
37
14.5
2.5
0.3
1.0
25.8
0.3
1.9
31.9
1.6
0.154
12.5
2,290
150
37
16.2
2.5
0.3
1.2
27.8
0.3
2.0
34.1
1.7
0.126
12.5
2,680
185
37
18.0
2.5
0.3
1.2
29.6
0.3
2.1
36.1
1.7
0.100
12.5
3,130
240
61
20.6
2.6
0.3
1.2
32.5
0.4
2.2
39.7
1.9
0.0762
12.5
3,940
300
61
23.1
2.8
0.4
1.2
35.7
0.4
2.3
43.1
2.0
0.0607
12.5
4,800
400
61
26.1
3.0
0.4
1.4
39.9
0.4
2.5
47.7
2.2
0.0475
12.5
6,050
500
61
29.2
3.2
0.4
1.4
43.0
0.4
2.6
51.0
2.3
0.0369
12.5
7,090
630
91
33.2
3.2
0.4
1.4
47.2
0.4
2.8
55.6
2.5
0.0286
12.5
8,810
10
4.2
2.5
0.3
1.2
31.9
0.4
2.2
39.1
1.9
1.840
12.5
2,360
16
5.3
2.5
0.3
1.2
34.1
0.4
2.3
41.5
2.0
1.160
12.5
2,740
25
6.6
2.5
0.3
1.2
36.9
0.4
2.4
44.5
2.1
0.734
12.5
3,280
35
7.9
2.5
0.3
1.4
39.9
0.4
2.5
47.7
2.2
0.529
12.5
3,860
50
19
9.1
2.5
0.3
1.4
42.7
0.4
2.6
50.7
2.3
0.391
12.5
4,500
70
19
11.0
2.5
0.3
1.4
46.5
0.4
2.8
54.9
2.5
0.270
12.5
5,520
6,770
95
19
12.9
2.5
0.3
1.6
51.0
0.4
2.9
59.6
2.7
0.195
12.5
120
37
14.5
2.5
0.3
1.6
54.5
0.4
3.1
63.5
2.8
0.154
12.5
7,910
150
37
16.2
2.5
0.3
1.6
57.9
0.4
3.2
67.1
3.0
0.126
12.5
9,080
185
37
18.0
2.5
0.3
1.6
61.8
0.4
3.4
71.4
3.2
0.100
12.5
10,630
240
61
20.6
2.6
0.3
1.8
68.5
0.4
3.6
78.5
3.4
0.0762
12.5
13,190
0.3
1.2
36.9
0.4
2.4
44.5
2.1
0.734
12.5
3,460
0.3
1.4
40.5
0.4
2.5
48.3
2.2
0.529
12.5
4,180
0.3
1.4
43.0
0.4
2.6
51.0
2.3
0.391
12.5
4,800
0.3
1.4
47.0
0.4
2.8
55.4
2.5
0.270
12.5
5,930
0.3
1.6
51.8
0.4
3.0
60.6
2.7
0.195
12.5
7,350
0.3
1.6
55.8
0.4
3.1
64.8
2.9
0.154
12.5
8,710
0.3
1.6
59.8
0.4
3.3
69.2
3.1
0.126
12.5
10,220
0.3
1.8
63.8
0.4
3.5
73.6
3.2
0.100
12.5
11,830
0.3
1.8
70.1
0.4
3.7
80.3
3.5
0.0762
12.5
14,540
2C
25
6.6
2.5
Earth
16
5.3
1.0
2C
35
7.9
2.5
Earth
25
6.6
1.2
2C
50
19
9.1
2.5
Earth
25
6.6
1.2
2C
70
19
11.0
2.5
Earth
35
7.9
1.2
2C
95
19
12.9
2.5
Earth
50
19
9.1
1.4
2C
120
37
14.5
2.5
Earth
70
19
11.0
1.4
2C
150
37
16.2
2.5
Earth
95
19
12.9
1.6
2C
185
37
18.0
2.5
Earth
95
19
12.9
1.6
2C
240
61
20.6
2.6
Earth
120
37
14.5
1.6
Offshore Cable
mm2
Thickness
of
Insulation
Instrumentation &
Communication Cable
Max.
overall
dia.
Min.
No. of
wires
VFD Cable
No.
Conductor
Nominal
Area
Technical Information
No. of
Cores
HV Power Cable
07
HV Power Cable
6/10kV RFOU, 6/10kV RFBU
No. of
Cores
No.
Conductor
Nominal
Area
Min.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
Thickness
of
Insulation
Dia of
copper
wire
for braid
Thickness
of
inner
covering
Nominal
dia.
inner
covering
Dia. of
wire for
armour
Thickness
of
sheath
mm
mm
mm
mm
mm
mm
Overall diameter
Nominal
Tolerance
mm
mm
Conductor
Resistance
(at 20)
(Max.)
Test
Voltage
Cable
Weight
/km
V/5min.
kg/km
16
5.3
3.4
0.3
1.0
18.5
0.3
1.6
24.0
1.3
1.160
21.0
960
25
6.6
3.4
0.3
1.0
19.8
0.3
1.7
25.5
1.3
0.734
21.0
1,130
35
7.9
3.4
0.3
1.0
21.0
0.3
1.7
26.7
1.4
0.529
21.0
1,280
50
19
9.1
3.4
0.3
1.0
22.3
0.3
1.8
28.2
1.4
0.391
21.0
1,480
70
19
11.0
3.4
0.3
1.0
24.1
0.3
1.8
30.0
1.5
0.270
21.0
1,770
95
19
12.9
3.4
0.3
1.0
26.0
0.3
1.9
32.1
1.6
0.195
21.0
2,130
120
37
14.5
3.4
0.3
1.2
28.0
0.3
2.0
34.3
1.7
0.154
21.0
2,500
150
37
16.2
3.4
0.3
1.2
29.6
0.3
2.1
36.1
1.7
0.126
21.0
2,860
185
37
18.0
3.4
0.3
1.2
31.4
0.4
2.2
38.6
1.8
0.100
21.0
3,410
240
61
20.6
3.4
0.4
1.2
34.5
0.4
2.3
41.9
2.0
0.0762
21.0
4,220
300
61
23.1
3.4
0.4
1.2
36.9
0.4
2.4
44.5
2.1
0.0607
21.0
4,960
400
61
26.1
3.4
0.4
1.4
40.7
0.4
2.5
48.5
2.2
0.0475
21.0
6,140
500
61
29.2
3.4
0.4
1.4
43.4
0.4
2.6
51.4
2.4
0.0369
21.0
7,140
630
91
33.2
3.4
0.4
1.4
47.6
0.4
2.8
56.0
2.5
0.0286
21.0
8,870
16
5.3
3.4
0.3
1.4
38.4
0.4
2.4
46.0
2.1
1.160
21.0
3,230
25
6.6
3.4
0.3
1.4
41.2
0.4
2.6
49.2
2.3
0.734
21.0
3,820
35
7.9
3.4
0.3
1.4
43.7
0.4
2.7
51.9
2.4
0.529
21.0
4,370
50
19
9.1
3.4
0.3
1.4
46.5
0.4
2.8
54.9
2.5
0.391
21.0
5,040
70
19
11.0
3.4
0.3
1.6
50.8
0.4
2.9
59.4
2.7
0.270
21.0
6,140
95
19
12.9
3.4
0.3
1.6
54.9
0.4
3.1
63.9
2.9
0.195
21.0
7,400
120
37
14.5
3.4
0.3
1.6
58.4
0.4
3.2
67.6
3.0
0.154
21.0
8,540
150
37
16.2
3.4
0.3
1.6
61.8
0.4
3.4
71.4
3.2
0.126
21.0
9,780
185
37
18.0
3.4
0.3
1.8
66.1
0.4
3.5
75.9
3.3
0.100
21.0
11,410
240
61
20.6
3.4
0.4
1.8
72.8
0.4
3.8
83.2
3.6
0.0762
21.0
14,240
2C
25
6.6
3.4
0.3
1.4
41.2
0.4
2.6
49.2
2.3
0.734
21.0
4,020
Earth
16
5.3
1.0
2C
35
7.9
3.4
0.3
1.4
44.0
0.4
2.7
52.2
2.4
0.529
21.0
4,680
0.3
1.4
46.5
0.4
2.8
54.9
2.5
0.391
21.0
5,320
0.3
1.6
50.9
0.4
2.9
59.5
2.7
0.270
21.0
6,520
0.3
1.6
55.4
0.4
3.1
64.4
2.9
0.195
21.0
7,940
0.3
1.6
59.2
0.4
3.3
68.6
3.0
0.154
21.0
9,340
0.3
1.8
63.8
0.4
3.5
73.6
3.2
0.126
21.0
10,990
0.3
1.8
67.3
0.4
3.6
77.3
3.4
0.100
21.0
12,520
0.4
1.8
74.0
0.4
3.9
84.6
3.7
0.0762
21.0
15,560
Earth
25
6.6
1.2
2C
50
19
9.1
3.4
Earth
25
6.6
1.2
2C
70
19
11.0
3.4
Earth
35
7.9
1.2
2C
95
19
12.9
3.4
Earth
50
19
9.1
1.4
2C
120
37
14.5
3.4
Earth
70
19
11.0
1.4
2C
150
37
16.2
3.4
Earth
95
19
12.9
1.6
2C
185
37
18.0
3.4
Earth
95
19
12.9
1.6
2C
240
61
20.6
3.4
Earth
120
37
14.5
1.6
08
Offshore Cable
HV Power Cable
mm
2C
6.6
mm
4.5
mm
0.3
mm
1.0
mm
22.0
Dia. of
wire for
armour
mm
0.3
Conductor
Resistance
(at 20)
(Max.)
Test
Voltage
mm
/km
V/5min.
kg/km
1.4
0.734
30.5
1,300
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.8
mm
27.9
Cable
Weight
35
7.9
4.5
0.3
1.0
23.2
0.3
1.8
29.1
1.5
0.529
30.5
1,460
50
19
9.1
4.5
0.3
1.0
24.5
0.3
1.9
30.6
1.5
0.391
30.5
1,660
70
19
11.0
4.5
0.3
1.0
26.3
0.3
1.9
32.4
1.6
0.270
30.5
1,960
95
19
12.9
4.5
0.3
1.2
28.6
0.3
2.0
34.9
1.7
0.195
30.5
2,370
120
37
14.5
4.5
0.3
1.2
30.2
0.4
2.1
37.2
1.8
0.154
30.5
2,810
150
37
16.2
4.5
0.3
1.2
31.8
0.4
2.2
39.0
1.9
0.126
30.5
3,180
185
37
18.0
4.5
0.3
1.2
33.6
0.4
2.2
40.8
1.9
0.100
30.5
3,630
240
61
20.6
4.5
0.4
1.2
36.7
0.4
2.4
44.3
2.1
0.0762
30.5
4,490
300
61
23.1
4.5
0.4
1.4
39.5
0.4
2.5
47.3
2.2
0.0607
30.5
5,290
400
61
26.1
4.5
0.4
1.4
42.9
0.4
2.6
50.9
2.3
0.0475
30.5
6,450
500
61
29.2
4.5
0.4
1.4
45.6
0.4
2.7
53.8
2.5
0.0369
30.5
7,460
630
91
33.2
4.5
0.4
1.6
50.2
0.4
2.9
58.8
2.7
0.0286
30.5
9,270
25
6.6
4.5
0.3
1.4
45.9
0.4
2.7
54.1
2.5
0.734
30.5
4,430
35
7.9
4.5
0.3
1.6
48.9
0.4
2.9
57.5
2.6
0.529
30.5
5,110
50
19
9.1
4.5
0.3
1.6
51.7
0.4
3.0
60.5
2.7
0.391
30.5
5,810
70
19
11.0
4.5
0.3
1.6
55.6
0.4
3.1
64.6
2.9
0.270
30.5
6,900
95
19
12.9
4.5
0.3
1.6
59.7
0.4
3.3
69.1
3.1
0.195
30.5
8,210
120
37
14.5
4.5
0.3
1.6
63.1
0.4
3.4
72.7
3.2
0.154
30.5
9,380
150
37
16.2
4.5
0.3
1.8
67.0
0.4
3.6
77.0
3.4
0.126
30.5
10,750
185
37
18.0
4.5
0.3
1.8
70.8
0.4
3.7
81.0
3.5
0.100
30.5
12,330
240
61
20.6
4.5
0.4
1.8
77.5
0.4
4.0
88.3
3.8
0.0762
30.5
15,260
25
6.6
4.5
0.3
1.4
45.9
0.4
2.7
54.1
2.5
0.734
30.5
4,670
0.3
1.6
48.9
0.4
2.9
57.5
2.6
0.529
30.5
5,420
0.3
1.6
51.7
0.4
3.0
60.5
2.7
0.391
30.5
6,140
0.3
1.6
55.6
0.4
3.1
64.6
2.9
0.270
30.5
7,320
0.3
1.6
59.7
0.4
3.3
69.1
3.1
0.195
30.5
8,730
0.3
1.8
63.9
0.4
3.5
73.7
3.2
0.154
30.5
10,250
0.3
1.8
68.0
0.4
3.6
78.0
3.4
0.126
30.5
11,830
0.3
1.8
71.5
0.4
3.8
81.9
3.6
0.100
30.5
13,430
0.4
1.8
78.3
0.4
4.0
89.1
3.9
0.0762
30.5
16,540
Earth
16
5.3
1.0
2C
35
7.9
4.5
Earth
25
6.6
1.2
2C
50
19
9.1
4.5
Earth
25
6.6
1.2
2C
70
19
11.0
4.5
Earth
35
7.9
1.2
2C
95
19
12.9
4.5
Earth
50
19
9.1
1.4
2C
120
37
14.5
4.5
Earth
70
19
11.0
1.4
2C
150
37
16.2
4.5
Earth
95
19
12.9
1.6
2C
185
37
18.0
4.5
Earth
95
19
12.9
1.6
2C
240
61
20.6
4.5
Earth
120
37
14.5
1.6
HV Power Cable
EA
25
mm2
Thickness
of
Insulation
Instrumentation &
Communication Cable
Max.
overall
dia.
Min.
No. of
wires
VFD Cable
No.
Conductor
Nominal
Area
Technical Information
No. of
Cores
Offshore Cable
09
0.6/1kV RU
11 ~ 14
15 ~ 18
0.6/1kV BU
19 ~ 22
23 ~ 26
HV Power Cable
0.6/1kV RU
Application Standard
- Design guide
- Flame retardant
- Halogen content
- Mud resistant
: UL 1581
Instrumentation &
Communication Cable
0.6/1kV RU
Sectional view
Classification
Code
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Conductor
Insulation
Construction
R
Cabling
Core identification
VFD Cable
1C
Off-white or Black
2C
Off-white, Black
3C / 2C + E
4C / 3C + E
5C / 4C + E
6C and over
Technical Information
Sheath
Offshore Cable
11
No.
2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
12
Conductor
Nominal
Area
Min.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
Offshore Cable
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
Thickness
of
Insulation
Thickness
of
sheath
mm
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
Overall diameter
Nominal
Tolerance
mm
mm
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.1
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.7
1.9
2.0
2.2
2.3
2.5
2.8
3.0
1.1
1.1
1.2
1.2
1.3
1.4
1.5
5.8
6.2
6.7
7.3
8.2
9.4
11.1
12.4
14.4
16.1
18.6
20.3
22.4
25.1
28.3
31.5
9.6
10.4
11.6
12.8
14.8
17.0
20.6
23.0
26.8
30.8
35.6
39.0
43.0
48.4
55.0
61.0
10.2
11.0
12.3
13.6
15.7
18.1
21.3
0.5
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.8
0.9
0.9
1.0
1.1
1.1
1.2
0.6
0.6
0.6
0.7
0.7
0.8
0.9
1.0
1.1
1.2
1.4
1.5
1.6
1.8
2.0
2.1
0.6
0.6
0.7
0.7
0.8
0.8
0.9
1.6
24.1
1.0
1.8
27.7
1.1
1.9
31.6
1.2
2.1
36.7
1.4
2.2
40.2
1.5
2.4
44.9
1.6
2.6
49.7
1.8
2.8
56.0
2.0
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
/km
-km
V/5min.
kg/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
60
70
90
110
160
230
340
450
600
810
1,100
1,360
1,650
2,070
2,690
3,340
140
170
230
290
390
550
840
1,090
1,450
2,000
2,690
3,300
4,000
5,030
6,550
8,090
160
210
270
360
510
730
1,000
1,360
1,730
2,350
3,190
3,970
4,970
5,980
7,660
4C+E
4C+E
4C+E
4C+E
4C+E
4C+E
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
mm
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
Thickness
of
sheath
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
mm
1.1
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.8
1.9
2.1
2.3
2.4
2.7
2.9
3.2
1.1
1.2
1.2
1.3
1.4
1.5
1.6
Overall diameter
Nominal
mm
10.2
11.0
12.3
13.6
15.7
18.1
21.9
24.5
29.0
32.9
38.2
41.9
46.1
52.1
59.0
65.6
11.1
12.3
13.5
15.1
17.5
20.1
23.8
Tolerance
mm
0.6
0.6
0.7
0.7
0.8
0.8
1.0
1.0
1.2
1.3
1.4
1.6
1.7
1.9
2.1
2.3
0.6
0.7
0.7
0.8
0.8
0.9
1.0
1.7
26.9
1.1
1.9
31.2
1.2
2.0
35.3
1.4
2.3
41.3
1.5
2.4
45.2
1.7
2.6
50.3
1.8
2.8
55.9
2.0
3.1
63.2
2.2
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.7
1.9
2.1
2.3
2.5
2.6
2.9
3.2
3.4
1.2
1.2
1.3
1.4
1.4
1.6
1.7
11.1
12.3
13.5
15.1
17.5
20.1
24.4
27.3
32.2
36.7
42.7
46.7
51.5
58.1
65.9
73.1
12.3
13.4
15.0
16.8
19.2
22.3
26.6
0.6
0.7
0.7
0.8
0.8
0.9
1.0
1.1
1.3
1.4
1.6
1.7
1.8
2.0
2.3
2.5
0.7
0.7
0.8
0.8
0.9
1.0
1.1
1.8
30.1
1.2
2.0
34.8
1.3
2.2
39.6
1.5
2.4
46.0
1.7
2.6
50.5
1.8
2.8
56.2
2.0
3.0
62.5
2.2
3.3
70.7
2.4
Conductor
Resistance
(at 20)
(Max.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
Insulation
Resistance
(at 20)
(Min.)
-km
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
Test
Voltage
Cable
Weight
V/5min.
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
kg/km
160
210
270
360
510
730
1,110
1,450
1,990
2,700
3,670
4,520
5,480
6,930
8,970
11,140
200
260
340
450
650
930
1,330
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
Thickness
of
Insulation
1,780
Instrumentation &
Communication Cable
3C+E
3C+E
3C+E
3C+E
3C+E
3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
EA
Max.
overall
dia.
2,330
3,140
4,300
5,330
6,620
8,060
10,400
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
Min.
No. of
wires
200
260
340
450
650
930
1,430
1,880
2,570
3,510
4,790
5,880
7,140
9,010
11,720
14,500
240
310
420
560
790
1,150
1,670
VFD Cable
No.
Conductor
Nominal
Area
2,250
2,940
4,000
Technical Information
No. of
Cores
HV Power Cable
0.6/1kV RU
5,430
6,750
8,350
10,230
13,220
Offshore Cable
13
No.
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
14
Conductor
Nominal
Area
Min.
No. of
wires
mm2
EA
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4
4
4
4
Offshore Cable
Max.
overall
dia.
mm
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
Thickness
of
Insulation
Thickness
of
sheath
mm
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.9
1.2
1.2
1.3
1.4
1.4
1.5
1.5
1.7
1.7
1.7
1.8
2.0
1.2
1.3
1.4
1.5
1.5
1.6
1.6
1.8
1.8
1.8
1.9
2.1
1.3
1.3
1.5
1.5
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.2
Overall diameter
Nominal
Tolerance
mm
mm
11.5
12.5
14.7
16.5
17.6
18.5
19.7
23.2
23.7
24.6
26.7
30.6
12.3
13.4
15.8
18.0
18.9
20.1
21.2
25.2
25.8
26.7
29.2
33.2
13.4
14.8
17.5
19.8
20.9
22.2
23.4
27.8
28.4
29.7
32.2
36.6
15.0
16.3
19.5
21.9
23.3
24.6
26.1
31.2
31.9
33.3
36.1
40.8
0.6
0.7
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.1
1.1
1.1
1.2
1.3
0.7
0.7
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.2
1.3
1.4
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
/km
-km
V/5min.
kg/km
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
940
940
940
940
940
940
940
940
940
940
940
940
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
190
240
310
390
450
500
580
740
800
870
1,060
1,300
230
290
380
480
550
620
710
920
1,000
1,090
1,340
1,620
290
390
490
640
720
820
950
1,210
1,330
1,480
1,780
2,150
390
510
660
850
980
1,100
1,290
1,660
1,830
2,030
2,450
2,920
HV Power Cable
Application Standard
- Design guide
- Flame retardant
- Halogen content
- Mud resistant
: UL 1581
Instrumentation &
Communication Cable
0.6/1kV RFOU
Sectional view
Classification
Code
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Conductor
Insulation
Construction
R
Cabling
Sheath
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C)
U
Core identification
VFD Cable
Armor
1C
Off-white or Black
2C
Off-white, Black
3C / 2C + E
4C / 3C + E
5C / 4C + E
6C and over
Technical Information
Inner covering
Offshore Cable
15
No.
2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
16
Conductor
Nominal
Area
Min.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
Offshore Cable
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
Thickness Thickness
of
of
Insulation
inner
covering
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
mm
Nominal
dia.
inner
covering
mm
Dia. of Thickness
Overall diameter
wire for
of
Nominal
Tolerarmour
sheath
ance
mm
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
mm
mm
mm
/km
-km
V/5min.
kg/km
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0
5.6
6.0
6.5
7.1
8.0
9.0
10.7
11.8
13.6
15.3
17.6
19.1
21.0
23.5
26.5
30.1
9.2
10.0
11.0
12.2
14.0
16.0
19.4
21.6
25.2
29.4
34.0
37.0
41.2
46.2
52.8
58.4
9.8
10.6
11.7
13.0
14.9
17.1
20.1
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.1
1.1
1.1
1.1
1.2
1.2
1.3
1.3
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.1
1.2
1.3
1.3
1.3
1.4
1.5
1.6
1.7
1.9
2.0
2.2
2.3
2.5
2.7
3.0
3.2
1.2
1.3
1.3
1.4
1.4
1.5
1.7
9.3
9.7
10.2
10.8
11.9
12.9
14.8
15.9
17.9
19.8
22.3
23.8
25.9
28.6
31.8
36.2
13.1
14.1
15.1
16.3
18.3
20.5
24.1
26.5
30.5
34.9
40.3
43.5
48.1
53.5
60.7
66.7
13.7
14.7
15.8
17.3
19.2
21.6
25.0
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.8
0.8
0.9
1.0
1.0
1.1
1.2
1.3
1.4
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.1
1.2
1.3
1.5
1.6
1.7
1.9
2.1
2.3
0.7
0.7
0.8
0.8
0.9
0.9
1.1
22.7
0.3
1.8
27.8
1.1
1.0
25.9
0.3
1.9
31.2
1.2
1.2
30.2
0.4
2.1
36.3
1.4
1.2
34.9
0.4
2.3
41.4
1.5
1.4
38.6
0.4
2.4
45.3
1.7
1.4
42.9
0.4
2.6
50.0
1.8
1.4
47.3
0.4
2.8
54.8
1.9
1.6
53.8
0.4
3.0
61.7
2.2
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
150
170
200
230
290
370
520
630
810
1,060
1,380
1,650
1,970
2,430
3,090
3,940
290
340
400
480
610
790
1,120
1,390
1,820
2,450
3,320
3,950
4,800
5,910
7,630
9,260
320
380
460
570
730
980
1,300
1.0
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
1,690
2,090
2,920
3,830
4,730
5,790
6,870
8,760
4C+E
4C+E
4C+E
4C+E
4C+E
4C+E
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
EA
mm
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0
mm
9.8
10.6
11.7
13.0
14.9
17.1
20.7
23.1
27.0
31.5
36.4
40.1
44.1
50.1
56.6
62.6
10.7
11.7
12.9
14.3
16.5
18.9
22.4
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.2
1.3
1.3
1.4
1.4
1.5
1.7
1.8
1.9
2.1
2.3
2.5
2.6
2.9
3.1
3.4
1.3
1.3
1.4
1.4
1.5
1.6
1.7
mm
13.7
14.7
15.8
17.3
19.2
21.6
25.6
28.2
32.3
37.6
42.9
47.0
51.2
57.8
64.7
71.3
14.8
15.8
17.2
18.6
21.0
23.6
27.3
mm
0.7
0.7
0.8
0.8
0.9
0.9
1.1
1.1
1.3
1.4
1.6
1.7
1.8
2.0
2.2
2.4
0.7
0.8
0.8
0.9
0.9
1.0
1.1
1.0
25.3
0.3
1.9
30.6
1.2
1.2
29.8
0.3
2.0
35.3
1.4
1.2
33.7
0.4
2.2
40.0
1.5
1.4
39.5
0.4
2.4
46.2
1.7
1.4
43.2
0.4
2.6
50.3
1.8
1.4
47.9
0.4
2.8
55.4
2.0
1.6
53.7
0.4
3.0
61.6
2.1
1.6
60.4
0.4
3.3
68.9
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.6
1.8
1.0
1.0
1.0
1.0
1.0
1.0
1.0
10.7
11.7
12.9
14.3
16.5
18.9
23.0
25.7
30.8
34.9
40.9
44.5
49.7
55.7
62.9
70.1
11.7
12.8
14.2
15.8
18.2
20.9
25.0
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.3
1.3
1.4
1.4
1.5
1.6
1.8
1.9
2.1
2.3
2.5
2.6
2.9
3.1
3.4
3.7
1.3
1.4
1.4
1.5
1.6
1.7
1.9
14.8
15.8
17.2
18.6
21.0
23.6
28.1
31.0
36.9
41.4
47.8
51.6
57.4
63.8
71.6
79.4
15.8
17.1
18.5
20.3
22.9
25.8
30.3
0.7
0.8
0.8
0.9
0.9
1.0
1.1
1.2
1.4
1.5
1.7
1.8
2.0
2.2
2.4
2.7
0.8
0.8
0.9
0.9
1.0
1.1
1.2
1.2
28.9
0.3
2.0
34.4
1.3
1.2
33.2
0.4
2.2
39.5
1.5
1.2
37.6
0.4
2.4
44.3
1.6
1.4
44.0
0.4
2.6
51.1
1.8
1.4
48.1
0.4
2.8
55.6
2.0
1.6
54.0
0.4
3.0
61.9
2.2
1.6
59.9
0.4
3.3
68.4
2.4
1.8
67.9
0.4
3.6
77.0
2.6
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
-km
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
Test
Voltage
Cable
Weight
V/5min.
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
kg/km
320
380
460
570
730
980
1,420
1,790
2,340
3,290
4,340
5,290
6,320
7,960
10,120
12,380
380
450
550
680
900
1,210
1,640
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
2,150
Instrumentation &
Communication Cable
3C+E
3C+E
3C+E
3C+E
3C+E
3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
Max.
overall
dia.
2,790
3,770
5,040
6,160
7,520
9,150
11,610
Min.
No. of
wires
380
450
550
680
900
1,210
1,770
2,250
3,150
4,160
5,580
6,700
8,200
10,140
12,960
16,000
430
520
640
810
1,070
1,450
2,030
VFD Cable
No.
Conductor
Nominal
Area
2,720
3,550
4,680
Technical Information
No. of
Cores
HV Power Cable
6,270
7,660
9,460
11,460
14,670
Offshore Cable
17
No.
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
18
Conductor
Nominal
Area
Min.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4
4
4
4
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
Thickness Thickness
of
of
Insulation
inner
covering
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
Nominal
dia.
inner
covering
mm
10.9
11.9
13.9
15.7
16.6
17.5
18.5
21.8
22.3
23.2
25.1
29.2
11.7
12.8
15.0
17.0
17.9
18.9
20.0
23.6
24.2
25.1
28.0
31.6
12.8
14.0
16.5
18.6
19.7
20.8
22.0
26.0
26.6
28.5
30.8
34.8
14.2
15.5
18.3
20.7
21.9
23.2
24.5
29.8
30.5
31.7
34.3
39.2
Dia. of Thickness
Overall diameter
wire for
of
Nominal
Tolerarmour
sheath
ance
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
mm
mm
1.3
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.7
1.8
1.9
2.0
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.9
1.9
2.0
2.1
2.3
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
2.1
2.2
2.4
15.0
16.0
18.2
20.2
21.1
22.2
23.2
26.7
27.2
28.3
30.4
34.7
15.8
17.1
19.5
21.5
22.6
23.6
24.9
28.7
29.3
30.4
33.5
37.7
17.1
18.3
21.0
23.3
24.4
25.7
26.9
31.3
31.9
34.0
36.9
41.3
18.5
20.0
23.0
25.6
26.8
28.3
29.6
35.3
36.6
37.8
40.6
45.9
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
mm
/km
-km
V/5min.
kg/km
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.1
1.1
1.2
1.3
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.2
1.2
1.2
1.3
1.4
0.8
0.8
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.3
1.4
1.5
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.4
1.4
1.4
1.5
1.7
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
940
940
940
940
940
940
940
940
940
940
940
940
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
360
430
520
630
690
770
850
1,040
1,120
1,220
1,420
1,750
410
500
610
730
820
900
1,010
1,250
1,340
1,460
1,800
2,190
500
600
740
910
1,010
1,120
1,260
1,570
1,700
1,940
2,370
2,790
610
750
930
1,160
1,290
1,440
1,630
2,130
2,410
2,600
3,070
3,680
HV Power Cable
0.6/1kV BU
Application Standard
- Design guide
- Flame retardant
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
- Mud resistant
: UL 1581
Instrumentation &
Communication Cable
0.6/1KV BU
Sectional view
Classification
Code
Insulation
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Conductor
Fire resisting layer
Construction
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Insulated cores shall be cabled
Cabling
Core identification
VFD Cable
1C
Off-white or Black
2C
Off-white, Black
3C / 2C + E
4C / 3C + E
5C / 4C + E
6C and over
Technical Information
Sheath
Offshore Cable
19
No.
2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
20
Conductor
Nominal
Area
Min.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
Offshore Cable
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
Thickness
of
Insulation
Thickness
of
sheath
mm
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
Overall diameter
Nominal
Tolerance
mm
mm
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.4
1.5
1.6
1.7
1.8
1.9
1.1
1.2
1.2
1.2
1.3
1.4
1.5
1.6
1.8
1.9
2.1
2.2
2.4
2.5
2.8
3.0
1.2
1.2
1.2
1.3
1.4
1.4
1.6
6.3
6.7
7.2
7.8
8.9
9.9
11.8
12.9
14.9
16.8
19.1
20.9
22.9
25.4
28.6
31.8
10.6
11.6
12.6
13.8
15.8
18.0
21.6
24.0
28.0
31.8
36.8
40.2
44.2
49.0
55.6
61.6
11.4
12.3
13.4
14.9
17.0
19.2
22.6
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7
0.8
0.9
0.9
1.0
1.1
1.2
1.3
0.6
0.6
0.7
0.7
0.8
0.8
0.9
1.0
1.1
1.3
1.4
1.5
1.6
1.8
2.0
2.1
0.6
0.7
0.7
0.7
0.8
0.9
1.0
1.7
25.4
1.1
1.8
29.0
1.2
1.9
32.6
1.3
2.1
37.8
1.4
2.3
41.7
1.6
2.4
46.0
1.7
2.6
50.4
1.8
2.8
56.8
2.0
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
/km
-km
V/5min.
kg/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
60
80
100
120
170
240
350
460
610
830
1,120
1,370
1,670
2,080
2,690
3,350
170
210
260
330
430
590
870
1,120
1,510
2,050
2,770
3,370
4,090
5,070
6,580
8,130
200
250
310
410
560
770
1,060
1,420
1,800
2,400
3,250
4,080
5,040
6,020
7,720
4C+E
4C+E
4C+E
4C+E
4C+E
4C+E
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
mm
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
Thickness
of
sheath
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
mm
1.2
1.2
1.2
1.3
1.4
1.4
1.6
1.7
1.8
2.0
2.2
2.3
2.5
2.7
2.9
3.2
1.2
1.2
1.3
1.3
1.4
1.5
1.7
mm
11.4
12.3
13.4
14.9
17.0
19.2
23.2
25.8
30.1
34.1
39.5
43.1
47.4
52.8
59.6
66.3
12.5
13.5
14.9
16.3
18.7
21.3
25.3
mm
0.6
0.7
0.7
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.5
1.6
1.7
1.9
2.1
2.3
0.7
0.7
0.7
0.8
0.9
0.9
1.1
1.8
28.3
1.1
1.9
32.4
1.3
2.1
36.7
1.4
2.3
42.5
1.6
2.5
46.8
1.7
2.6
51.5
1.8
2.8
56.7
2.0
3.1
64.0
2.2
1.2
1.2
1.3
1.3
1.4
1.5
1.7
1.8
2.0
2.1
2.4
2.5
2.7
2.9
3.2
3.5
1.2
1.3
1.3
1.4
1.5
1.6
1.8
12.5
13.5
14.9
16.3
18.7
21.3
25.8
28.7
33.6
37.9
44.1
48.1
52.9
58.8
66.7
74.0
13.7
15.0
16.3
18.1
20.8
23.7
28.1
0.7
0.7
0.7
0.8
0.9
0.9
1.1
1.2
1.3
1.4
1.6
1.7
1.9
2.1
2.3
2.5
0.7
0.8
0.8
0.8
0.9
1.0
1.1
1.9
31.7
1.3
2.1
36.3
1.4
2.2
40.9
1.5
2.5
47.6
1.7
2.7
52.3
1.9
2.9
57.8
2.0
3.1
63.6
2.2
3.4
71.8
2.5
Overall diameter
Nominal
Tolerance
Conductor
Resistance
(at 20)
(Max.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
Insulation
Resistance
(at 20)
(Min.)
-km
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
Test
Voltage
Cable
Weight
V/5min.
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
kg/km
200
250
310
410
560
770
1,160
1,510
2,040
2,770
3,760
4,600
5,580
6,970
9,010
11,190
240
300
390
500
710
990
1,400
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
Thickness
of
Insulation
1,850
Instrumentation &
Communication Cable
3C+E
3C+E
3C+E
3C+E
3C+E
3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
EA
Max.
overall
dia.
2,390
3,230
4,370
5,460
6,710
8,110
10,460
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
Min.
No. of
wires
240
300
390
500
710
990
1,500
1,950
2,650
3,580
4,890
5,980
7,260
9,060
11,770
14,600
290
370
470
620
870
1,230
1,750
VFD Cable
No.
Conductor
Nominal
Area
2,340
3,030
4,070
Technical Information
No. of
Cores
HV Power Cable
0.6/1kV BU
5,560
6,910
8,500
10,330
13,340
Offshore Cable
21
No.
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
22
Conductor
Nominal
Area
Min.
No. of
wires
mm2
EA
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4
4
4
4
Offshore Cable
Max.
overall
dia.
mm
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
Thickness
of
Insulation
Thickness
of
sheath
mm
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.3
1.3
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
1.2
1.3
1.4
1.5
1.5
1.6
1.6
1.8
1.8
1.9
1.9
2.1
1.3
1.3
1.5
1.5
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.2
1.3
1.4
1.5
1.6
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.4
Overall diameter
Nominal
Tolerance
mm
mm
12.9
14.2
16.5
18.8
20.0
21.1
22.4
26.4
27.0
28.2
30.8
34.8
13.7
15.1
17.8
20.2
21.3
22.7
23.9
28.4
29.2
30.5
32.9
37.4
15.0
16.3
19.5
21.9
23.3
24.6
26.1
31.2
31.9
33.3
36.1
40.8
16.3
18.0
21.3
24.2
25.7
27.1
29.0
34.4
35.2
36.7
39.8
45.2
0.7
0.7
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.2
1.2
1.2
1.3
1.4
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
0.8
0.8
0.9
1.0
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.7
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
/km
-km
V/5min.
kg/km
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
940
940
940
940
940
940
940
940
940
940
940
940
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
230
300
370
480
550
610
710
900
980
1,090
1,330
1,580
270
350
450
580
650
740
850
1,090
1,210
1,340
1,600
1,920
340
440
580
730
840
940
1,100
1,430
1,570
1,730
2,090
2,480
440
580
740
960
1,110
1,250
1,480
1,880
2,070
2,290
2,770
3,320
HV Power Cable
Application Standard
- Design guide
- Flame retardant
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
- Mud resistant
: UL 1581
Instrumentation &
Communication Cable
0.6/1kV BFOU
Sectional view
Classification
Code
Insulation
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Conductor
Fire resisting layer
Construction
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Insulated cores shall be cabled
Cabling
Sheath
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C)
U
Core identification
1C
Off-white or Black
2C
Off-white, Black
3C / 2C + E
4C / 3C + E
5C / 4C + E
6C and over
Technical Information
Armor
VFD Cable
Offshore Cable
23
No.
2C+E
2C+E
2C+E
2C+E
2C+E
2C+E
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
2C
Earth
24
Conductor
Nominal
Area
Min.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
Offshore Cable
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
mm
mm
Dia. of
wire for
armour
mm
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
mm
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.4
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0
6.1
6.5
7.0
7.6
8.5
9.5
11.2
12.3
14.1
15.8
18.1
19.7
21.5
23.8
26.8
30.4
10.2
11.0
12.0
13.2
15.0
17.0
20.4
22.6
26.2
30.4
35.0
38.6
42.2
46.8
53.4
59.0
10.8
11.7
12.8
14.1
16.0
18.2
21.2
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.1
1.1
1.1
1.2
1.2
1.2
1.3
1.3
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.1
1.3
1.3
1.3
1.4
1.5
1.5
1.7
1.8
1.9
2.1
2.3
2.4
2.6
2.7
3.0
3.2
1.3
1.3
1.4
1.4
1.5
1.6
1.7
9.8
10.2
10.7
11.5
12.4
13.4
15.3
16.4
18.4
20.3
22.8
24.4
26.4
28.9
32.1
36.5
14.3
15.1
16.1
17.5
19.5
21.5
25.3
27.7
31.5
36.5
41.5
45.3
49.3
54.1
61.3
67.3
14.9
15.8
17.1
18.4
20.5
22.9
26.1
0.6
0.6
0.6
0.6
0.7
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
1.4
0.7
0.8
0.8
0.8
0.9
0.9
1.1
1.1
1.2
1.4
1.5
1.7
1.8
1.9
2.1
2.3
0.7
0.8
0.8
0.9
0.9
1.0
1.1
1.0
23.8
0.3
1.8
28.9
1.2
1.0
27.0
0.3
1.9
32.3
1.3
1.2
31.2
0.4
2.1
37.3
1.4
1.2
36.0
0.4
2.3
42.5
1.6
1.4
39.9
0.4
2.5
46.8
1.7
1.4
44.0
0.4
2.6
51.1
1.8
1.4
48.0
0.4
2.8
55.5
2.0
1.6
54.6
0.4
3.1
62.7
2.2
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
/km
-km
V/5min.
kg/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
170
190
210
250
310
390
530
650
830
1,080
1,410
1,680
2,000
2,440
3,100
3,960
330
380
450
540
660
840
1,170
1,450
1,870
2,620
3,410
4,130
4,900
5,950
7,670
9,310
370
430
520
630
800
1,050
1,360
1,750
2,150
2,990
3,910
4,850
5,880
6,920
8,860
4C+E
4C+E
4C+E
4C+E
4C+E
4C+E
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
4C
Earth
EA
mm
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
1.7
2.2
2.7
3.3
4.2
5.3
6.6
5.3
7.9
6.6
9.1
6.6
11.0
7.9
12.9
9.1
14.5
11.0
16.2
12.9
18.0
12.9
20.6
14.5
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
7
7
7
7
7
7
7
7
7
7
19
7
19
7
19
19
37
19
37
19
37
19
61
37
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.2
1.2
1.4
1.2
1.4
1.2
1.6
1.4
1.6
1.4
1.8
1.6
2.0
1.6
2.2
1.6
Dia. of
wire for
armour
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.6
1.0
1.0
1.0
1.0
1.0
1.0
1.0
mm
10.8
11.7
12.8
14.1
16.0
18.2
21.8
24.2
28.9
32.5
37.5
41.3
45.2
50.8
57.2
63.3
11.9
12.9
14.1
15.5
17.7
20.1
23.7
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
mm
1.3
1.3
1.4
1.4
1.5
1.6
1.7
1.8
2.0
2.2
2.4
2.5
2.7
2.9
3.2
3.4
1.3
1.4
1.4
1.5
1.6
1.7
1.8
mm
14.9
15.8
17.1
18.4
20.5
22.9
26.7
29.3
34.4
38.8
44.2
48.2
52.5
58.5
65.5
72.0
16.0
17.2
18.4
20.0
22.4
25.0
28.8
mm
0.7
0.8
0.8
0.9
0.9
1.0
1.1
1.2
1.3
1.5
1.6
1.7
1.9
2.1
2.3
2.5
0.8
0.8
0.9
0.9
1.0
1.1
1.2
1.0
26.5
0.3
1.9
31.8
1.3
1.2
31.0
0.4
2.1
37.1
1.4
1.2
34.9
0.4
2.3
41.4
1.5
1.4
40.7
0.4
2.5
47.6
1.7
1.4
44.6
0.4
2.7
51.9
1.9
1.6
49.7
0.4
2.9
57.4
2.0
1.6
54.5
0.4
3.0
62.4
2.2
1.6
61.2
0.4
3.3
69.7
2.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.6
1.8
1.0
1.0
1.0
1.0
1.0
1.0
1.0
11.9
12.9
14.1
15.5
17.7
20.1
24.2
26.9
32.0
36.1
42.1
45.9
50.9
56.4
63.7
70.8
13.1
14.2
15.5
17.1
19.6
22.3
26.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
1.3
1.4
1.4
1.5
1.6
1.7
1.8
1.9
2.1
2.3
2.6
2.7
2.9
3.1
3.4
3.7
1.4
1.4
1.5
1.5
1.6
1.7
1.9
16.0
17.2
18.4
20.0
22.4
25.0
29.3
32.2
38.1
42.6
49.2
53.2
58.6
64.5
72.4
80.1
17.4
18.5
20.0
21.6
24.3
27.2
31.6
0.8
0.8
0.9
0.9
1.0
1.1
1.2
1.3
1.4
1.6
1.8
1.9
2.1
2.2
2.5
2.7
0.8
0.9
0.9
0.9
1.0
1.1
1.2
1.2
30.3
0.4
2.1
36.4
1.4
1.2
34.5
0.4
2.2
40.8
1.5
1.4
39.3
0.4
2.4
46.0
1.7
1.4
45.4
0.4
2.7
52.7
1.9
1.6
50.3
0.4
2.9
58.0
2.0
1.6
55.4
0.4
3.1
63.5
2.2
1.6
60.8
0.4
3.3
69.3
2.4
1.8
68.8
0.4
3.6
77.9
2.6
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
/km
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
12.2
7.56
4.70
3.110
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
12.2
7.56
4.70
3.110
1.840
1.160
0.734
1.160
0.529
0.734
0.391
0.734
0.270
0.529
0.195
0.391
0.154
0.270
0.126
0.195
0.100
0.195
0.0762
0.154
-km
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
1,320
1,110
940
800
650
540
520
450
440
380
370
330
330
330
320
310
1,320
1,110
940
800
650
540
520
540
450
520
440
520
380
450
370
440
330
380
330
370
330
370
320
330
Test
Voltage
Cable
Weight
V/5min.
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
kg/km
370
430
520
630
800
1,050
1,470
1,850
2,510
3,380
4,440
5,390
6,440
8,010
10,200
12,440
430
510
610
750
980
1,290
1,730
mm2
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
1.5
2.5
4
6
10
16
25
16
35
25
50
25
70
35
95
50
120
70
150
95
185
95
240
120
2,220
Instrumentation &
Communication Cable
3C+E
3C+E
3C+E
3C+E
3C+E
3C+E
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
3C
Earth
Max.
overall
dia.
2,970
3,870
5,160
6,310
7,770
9,220
11,680
Min.
No. of
wires
430
510
610
750
980
1,290
1,830
2,320
3,230
4,240
5,700
6,850
8,310
10,200
13,030
16,060
500
590
720
880
1,160
1,540
2,110
VFD Cable
No.
Conductor
Nominal
Area
2,910
3,640
4,840
Technical Information
No. of
Cores
HV Power Cable
6,420
7,950
9,630
11,540
14,760
Offshore Cable
25
No.
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
5
7
9
12
14
16
19
24
27
30
37
44
26
Conductor
Nominal
Area
Min.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
4
4
4
4
4
4
4
4
4
4
4
4
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
2.7
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
mm
12.3
13.4
15.7
17.8
18.8
19.9
21.0
24.8
25.4
26.4
29.4
33.2
13.1
14.3
16.8
19.0
20.1
21.3
22.5
26.6
28.0
29.1
31.5
35.6
14.2
15.5
18.3
20.7
21.9
23.2
24.5
29.8
30.5
31.7
34.3
39.2
15.5
17.0
20.1
22.8
24.1
25.5
27.0
32.8
33.6
34.9
37.8
43.2
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.3
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.2
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.0
2.1
2.3
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
2.1
2.2
2.4
1.5
1.5
1.7
1.8
1.8
1.9
1.9
2.2
2.2
2.3
2.4
2.6
mm
16.4
17.7
20.2
22.5
23.5
24.6
25.9
29.9
30.7
31.7
34.9
39.5
17.4
18.6
21.3
23.7
25.0
26.2
27.6
31.9
33.5
34.6
37.6
42.1
18.5
20.0
23.0
25.6
26.8
28.3
29.6
35.3
36.6
37.8
40.6
45.9
20.0
21.5
25.0
27.9
29.2
30.8
32.3
39.1
39.9
41.4
44.5
50.3
mm
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.5
0.8
0.9
0.9
1.0
1.1
1.1
1.1
1.3
1.3
1.3
1.4
1.6
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.4
1.4
1.4
1.5
1.7
0.9
0.9
1.1
1.1
1.2
1.2
1.3
1.5
1.5
1.5
1.6
1.8
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
/km
-km
V/5min.
kg/km
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
18.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
12.2
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
7.56
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
4.70
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,490
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,320
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
1,110
940
940
940
940
940
940
940
940
940
940
940
940
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
420
500
610
750
820
900
1,010
1,240
1,350
1,450
1,790
2,200
480
570
700
850
950
1,050
1,180
1,460
1,670
1,800
2,190
2,580
560
680
840
1,040
1,150
1,280
1,440
1,890
2,140
2,310
2,710
3,250
680
830
1,040
1,300
1,450
1,620
1,830
2,500
2,700
2,940
3,460
4,160
250V RU(c)
28 ~ 30
250V RU(i)
31 ~ 33
250V RU(i&c)
34 ~ 36
37 ~ 39
40 ~ 42
43 ~ 45
250V BU(c)
46 ~ 48
250V BU(i)
49 ~ 51
250V BU(i&c)
52 ~ 54
55 ~ 57
58 ~ 60
61 ~ 63
Application Standard
- Design guide
- Flame retardant
250V RU(c)
- Halogen content
- Mud resistant
: UL 1581
Construction
Sectional view
Classification
Code
Conductor
Insulation
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Twisting
Cabling
Collective screen
(c)
Sheath
Core identification
28
Offshore Cable
mm
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.0
1.1
1.1
1.2
1.2
1.3
1.3
1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.8
1.0
1.1
1.2
1.2
1.3
1.3
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.8
1.0
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.7
1.9
2.1
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.7
1.7
1.7
1.8
1.9
2.0
2.2
Overall diameter
Nominal
Tolerance
mm
mm
7.0
10.4
11.1
12.0
13.4
14.5
14.5
15.4
17.5
18.2
18.8
20.4
21.3
24.3
27.9
7.4
11.1
12.1
12.8
14.5
15.5
15.5
16.5
18.7
19.7
20.4
21.9
23.1
26.3
30.2
8.4
13.0
14.1
15.0
17.0
18.2
18.2
19.6
22.2
23.1
24.0
26.0
27.2
31.4
36.0
9.4
14.6
15.6
16.8
18.8
20.4
20.4
21.8
24.9
25.9
26.9
29.4
30.9
35.2
40.4
0.5
0.6
0.6
0.7
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
0.5
0.6
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.2
0.6
0.7
0.7
0.8
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.4
0.6
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.2
1.4
1.5
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
80
140
170
210
240
280
310
340
420
470
530
600
680
850
1,110
90
160
200
240
290
330
360
400
490
570
640
720
830
1,030
1,350
110
210
270
320
390
450
490
560
680
780
870
1,000
1,140
1,460
1,900
150
270
340
430
510
600
660
740
930
1,060
1,200
1,390
1,610
2,000
2,620
Offshore Cable
EA
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Thickness
of
Insulation
Instrumentation &
Communication Cable
mm2
Max.
overall
dia.
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
Max.
No. of
wires
VFD Cable
No.
Conductor
Nominal
Area
Technical Information
No. of
Pairs
HV Power Cable
250V RU(c)
29
No.
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
30
Conductor
Nominal
Area
Max.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
Insulation
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.0
1.2
1.2
1.2
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
2.0
1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.9
2.1
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.4
1.1
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.0
2.0
2.2
2.3
2.6
Overall diameter
Nominal
Tolerance
mm
mm
7.4
11.6
12.3
13.5
15.1
17.1
17.1
18.3
20.8
22.2
23.1
24.5
26.6
29.7
34.3
7.8
12.3
13.1
14.5
16.0
18.2
18.2
19.7
22.4
23.6
24.6
26.4
28.6
32.0
36.9
9.1
14.5
15.4
17.1
18.9
21.5
21.5
23.2
26.4
28.1
29.5
31.5
34.2
38.0
44.0
10.0
16.0
17.3
19.0
21.3
24.2
24.2
26.1
30.0
31.9
33.4
35.5
38.7
43.0
49.8
0.5
0.6
0.7
0.7
0.8
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.3
0.5
0.7
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.3
1.4
0.6
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.6
0.6
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
100
180
220
270
330
390
430
470
580
680
760
850
1,000
1,250
1,630
110
210
260
320
380
460
500
570
710
810
910
1,030
1,210
1,510
1,980
140
270
340
430
520
620
680
780
960
1,120
1,290
1,460
1,710
2,100
2,780
180
350
460
570
700
840
930
1,070
1,340
1,560
1,790
2,010
2,380
2,930
3,880
HV Power Cable
250V RU(i)
Application Standard
- Design guide
- Flame retardant
- Halogen content
- Mud resistant
: UL 1581
Instrumentation &
Communication Cable
250V RU(i)
Sectional view
Classification
Code
Conductor
Insulation
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Twisting
Individual screen
Construction
(i)
Cabling
VFD Cable
Sheath
Core identification
Technical Information
Offshore Cable
31
No.
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
32
Conductor
Nominal
Area
Max.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
Insulation
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.0
1.1
1.2
1.2
1.3
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.0
1.2
1.2
1.2
1.3
1.3
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.0
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
1.1
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.8
1.8
1.9
1.9
2.2
2.3
Overall diameter
Nominal
Tolerance
mm
mm
7.0
11.1
11.9
13.0
14.7
15.2
15.2
16.8
19.0
20.0
20.9
22.6
23.1
27.0
29.6
7.4
12.0
12.7
13.8
15.6
16.2
16.2
17.9
20.5
21.3
22.6
24.2
24.9
29.3
31.9
8.4
13.7
14.7
16.1
18.2
18.9
18.9
20.9
24.0
25.1
26.4
28.5
29.3
34.4
37.5
9.4
15.3
16.2
18.0
20.3
21.1
21.1
23.4
26.8
28.0
29.7
32.0
32.7
38.6
42.0
0.5
0.6
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.2
0.5
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.2
1.3
0.6
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
0.6
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.3
1.5
1.6
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
40
70
110
140
170
200
240
270
340
400
470
540
630
800
1,060
90
180
230
280
350
400
440
510
630
720
830
930
1,080
1,380
1,760
120
230
300
370
450
520
570
660
820
960
1,080
1,240
1,430
1,820
2,330
150
290
380
490
600
690
760
880
1,090
1,280
1,470
1,680
1,920
2,470
3,170
mm
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.1
1.0
1.2
1.2
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.2
1.1
1.3
1.3
1.4
1.5
1.6
1.6
1.6
1.8
1.8
1.9
1.9
2.0
2.2
2.4
1.1
1.3
1.4
1.5
1.5
1.7
1.7
1.7
1.9
1.9
2.0
2.1
2.2
2.4
2.6
Overall diameter
Nominal
Tolerance
mm
mm
7.4
12.0
12.8
14.2
15.7
17.9
17.9
19.1
21.7
23.2
24.2
25.8
28.0
31.4
36.2
7.8
12.8
13.5
15.1
16.9
19.0
19.0
20.5
23.3
24.9
25.9
27.7
30.0
33.6
38.8
9.1
14.9
15.8
17.6
19.7
22.4
22.4
24.0
27.6
29.3
30.8
32.7
35.5
39.6
45.7
10.0
16.5
17.7
19.7
21.9
25.1
25.1
26.9
31.1
32.9
34.5
36.9
40.0
44.6
51.4
0.5
0.7
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.4
0.5
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.5
0.6
0.7
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.7
0.6
0.8
0.8
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
150
280
340
420
490
590
630
700
850
980
1,100
1,230
1,430
1,760
2,360
110
220
280
360
450
520
580
660
820
970
1,090
1,250
1,460
1,830
2,410
150
290
370
480
590
710
780
880
1,110
1,300
1,490
1,670
1,960
2,460
3,220
190
370
500
640
770
950
1,060
1,190
1,510
1,750
2,020
2,290
2,690
3,370
4,420
Offshore Cable
EA
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Thickness
of
Insulation
Instrumentation &
Communication Cable
mm2
Max.
overall
dia.
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
Max.
No. of
wires
VFD Cable
No.
Conductor
Nominal
Area
Technical Information
No. of
Triads
HV Power Cable
250V RU(i)
33
Cable Designation
250V RU(i&c)
Application Standard
- Design guide
- Flame retardant
250V RU(i&c)
- Halogen content
- Mud resistant
: UL 1581
Construction
Sectional view
Classification
Code
Conductor
Insulation
Twisting
Individual screen
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
Cabling
Collective screen
(c)
Sheath
Core identification
34
Offshore Cable
mm
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.2
1.2
1.2
1.3
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.2
1.2
1.3
1.3
1.3
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.8
1.8
1.9
1.9
2.2
2.3
Overall diameter
Nominal
Tolerance
mm
mm
11.4
12.0
13.1
14.8
15.3
15.3
16.9
19.1
20.1
21.0
22.7
23.2
27.1
29.7
12.1
12.8
14.1
15.7
16.3
16.3
18.0
20.6
21.4
22.7
24.3
25.0
29.4
32.0
13.8
14.8
16.2
18.3
19.0
19.0
21.0
24.1
25.2
26.5
28.6
29.4
34.5
37.6
15.4
16.3
18.1
20.4
21.2
21.2
23.5
26.9
28.1
29.8
32.1
32.8
38.7
42.1
0.6
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.2
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.3
1.5
1.6
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
170
210
260
310
350
380
440
530
620
700
800
900
1,130
1,470
200
250
310
370
420
460
530
650
740
860
960
1,110
1,410
1,800
240
320
390
470
540
590
680
840
980
1,110
1,270
1,460
1,850
2,360
320
400
510
620
710
790
910
1,120
1,310
1,510
1,710
1,960
2,510
3,210
Offshore Cable
EA
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Thickness
of
Insulation
Instrumentation &
Communication Cable
mm2
Max.
overall
dia.
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
Max.
No. of
wires
VFD Cable
No.
Conductor
Nominal
Area
Technical Information
No. of
Pairs
HV Power Cable
250V RU(i&c)
35
No.
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
36
Conductor
Nominal
Area
Max.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
Insulation
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.2
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.1
1.2
1.2
1.3
1.4
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.2
1.3
1.3
1.4
1.5
1.6
1.6
1.6
1.8
1.8
1.9
1.9
2.0
2.2
2.4
1.4
1.4
1.5
1.6
1.7
1.7
1.7
1.9
2.0
2.0
2.1
2.2
2.4
2.6
Overall diameter
Nominal
Tolerance
mm
mm
12.1
12.9
14.3
15.8
18.0
18.0
19.2
21.8
23.3
24.3
25.9
28.1
31.5
36.3
12.9
13.6
15.2
17.0
19.1
19.1
20.6
23.4
25.0
26.0
27.8
30.1
33.7
38.9
15.0
15.9
17.7
19.8
22.5
22.5
24.1
27.7
29.4
30.9
32.8
35.6
39.7
45.8
16.8
17.8
19.8
22.2
25.2
25.2
27.0
31.2
33.2
34.6
37.0
40.1
44.7
51.5
0.7
0.7
0.7
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.4
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.5
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.7
0.8
0.8
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
200
260
320
380
460
510
570
700
820
920
1,050
1,230
1,540
2,010
240
300
380
470
550
600
690
850
990
1,120
1,270
1,490
1,870
2,450
310
390
500
610
730
810
900
1,140
1,330
1,520
1,700
2,000
2,490
3,270
400
520
660
810
980
1,080
1,220
1,550
1,810
2,050
2,330
2,730
3,410
4,470
HV Power Cable
Application Standard
- Design guide
- Flame retardant
- Halogen content
- Mud resistant
: UL 1581
Instrumentation &
Communication Cable
250V RFOU(c)
Sectional view
Classification
Code
Conductor
Insulation
Construction
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
R
Twisting
Cabling
Inner covering
Armor
Sheath
(c)
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C)
U
VFD Cable
Core identification
Technical Information
Offshore Cable
37
Conductor
Nominal
Area
Max.
No. of
wires
Max.
overall
dia.
No.
mm2
EA
mm
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4Pi
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
38
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
mm
6.8
10.0
10.7
11.4
12.8
13.7
13.7
14.6
16.5
17.2
17.8
19.2
20.1
22.9
26.1
7.2
10.7
11.5
12.2
13.7
14.7
14.7
15.7
17.7
18.5
19.2
20.7
21.7
24.7
29.0
8.2
12.4
13.3
14.2
16.0
17.2
17.2
18.4
20.8
21.7
22.6
24.4
25.6
30.0
34.2
9.0
13.8
14.8
15.8
17.8
19.2
19.2
20.6
23.3
24.3
25.3
28.2
29.5
33.6
38.8
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.1
1.3
1.3
1.3
1.4
1.4
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.1
1.3
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.7
1.8
2.0
1.2
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
1.9
2.1
2.2
1.2
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.0
2.2
2.4
mm
10.5
14.1
14.8
15.5
17.1
18.0
18.0
18.9
21.0
21.7
22.5
23.9
25.0
28.0
31.4
10.9
14.8
15.6
16.3
18.0
19.0
19.0
20.2
22.4
23.2
23.9
25.6
26.6
29.8
34.5
12.1
16.5
17.6
18.5
20.5
21.7
21.7
23.1
25.7
26.6
27.7
29.5
30.9
35.7
40.5
12.9
18.1
19.1
20.3
22.5
23.9
23.9
25.5
28.4
29.4
30.6
33.7
35.0
39.9
45.5
mm
0.6
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
0.6
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.3
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.1
1.2
1.2
1.4
1.5
0.7
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.2
1.3
1.4
1.5
1.7
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
200
300
340
380
450
490
520
560
660
730
800
880
980
1,190
1,470
210
340
380
430
500
550
580
650
760
840
920
1,030
1,140
1,370
1,820
250
400
470
530
630
700
740
820
980
1,090
1,210
1,340
1,510
1,940
2,510
290
480
570
660
780
880
940
1,050
1,250
1,400
1,560
1,850
2,070
2,630
3,380
mm2
EA
mm
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
mm
7.2
11.0
11.7
12.9
14.3
16.1
16.1
17.3
19.6
20.8
21.7
23.1
25.0
28.5
32.7
7.6
11.7
12.5
13.7
15.2
17.2
17.2
18.5
21.0
22.2
23.2
24.8
26.8
30.6
35.1
8.7
13.7
14.6
16.1
17.9
20.3
20.3
21.8
24.8
26.3
28.3
30.1
32.6
36.2
42.0
9.6
15.2
16.3
18.0
20.1
22.8
22.8
24.5
28.8
30.5
31.8
33.9
36.7
41.2
47.4
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.2
1.2
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
1.9
2.1
2.3
1.2
1.4
1.4
1.5
1.6
1.7
1.7
1.7
1.8
1.9
2.0
2.1
2.2
2.3
2.5
1.2
1.5
1.5
1.6
1.7
1.8
1.8
1.8
2.0
2.1
2.1
2.2
2.3
2.5
2.8
mm
10.9
15.1
15.8
17.2
18.6
20.6
20.6
21.8
24.3
25.7
26.6
28.2
30.3
34.0
39.0
11.5
15.8
16.8
18.0
19.7
21.7
21.7
23.2
25.9
27.1
28.3
29.9
32.1
36.7
41.6
12.6
18.0
18.9
20.6
22.6
25.2
25.2
26.7
29.9
31.6
33.8
36.2
38.9
42.7
48.9
13.5
19.7
20.8
22.7
25.0
27.9
27.9
29.6
34.3
36.6
37.9
40.2
43.2
48.1
54.9
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
mm
/km
-km
V/5min.
kg/km
0.6
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.1
1.2
1.3
1.5
0.6
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.5
0.7
0.8
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.8
0.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.7
1.9
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
220
350
400
470
540
630
670
730
870
980
1,070
1,190
1,360
1,710
2,240
240
390
460
530
620
710
760
840
1,000
1,120
1,250
1,380
1,580
2,090
2,620
290
480
570
670
790
930
990
1,090
1,310
1,490
1,750
2,030
2,320
2,770
3,560
340
590
710
850
1,010
1,180
1,270
1,410
1,800
2,140
2,370
2,640
3,020
3,730
4,770
Offshore Cable
No.
Instrumentation &
Communication Cable
Max.
overall
dia.
Max.
No. of
wires
VFD Cable
Conductor
Nominal
Area
Technical Information
No. of
Triads
HV Power Cable
39
Application Standard
- Design guide
- Flame retardant
250V RFOU(i)
- Halogen content
- Mud resistant
: UL 1581
Construction
Sectional view
Classification
Code
Conductor
Insulation
Twisting
Individual screen
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
Cabling
Inner covering
Armor
Sheath
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C)
U
Core identification
40
Offshore Cable
mm2
EA
mm
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
mm
6.8
10.7
11.3
12.4
13.9
14.4
14.4
15.8
18.0
18.8
19.7
21.2
21.7
25.4
28.4
7.2
11.4
12.1
13.2
14.8
15.4
15.4
16.9
19.3
20.1
21.2
22.8
23.3
28.1
30.5
8.2
13.1
13.9
15.3
17.2
17.9
17.9
19.7
22.6
23.5
24.8
26.7
28.1
32.8
35.7
9.0
14.5
15.4
17.0
19.1
19.9
19.9
22.0
25.2
26.2
28.5
30.6
31.3
36.6
40.2
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.1
1.3
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.7
1.9
2.0
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
1.2
1.4
1.4
1.5
1.5
1.6
1.6
1.6
1.8
1.8
1.8
1.9
2.0
2.2
2.3
1.2
1.4
1.5
1.5
1.6
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.1
2.3
2.5
mm
10.5
14.8
15.4
16.5
18.2
18.7
18.7
20.3
22.7
23.5
24.4
26.1
26.6
30.7
33.9
10.9
15.5
16.2
17.5
19.1
19.9
19.9
21.4
24.0
25.0
26.1
27.9
28.4
33.6
36.6
12.1
17.4
18.2
19.8
21.7
22.6
22.6
24.4
27.7
28.6
29.9
32.0
33.6
39.1
42.2
12.9
18.8
19.9
21.5
23.8
24.6
24.6
26.9
30.5
31.5
34.0
36.7
37.4
43.1
47.1
mm
0.6
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.3
0.6
0.8
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
0.7
0.8
0.8
0.9
1.0
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.5
1.6
0.7
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.7
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
200
330
380
430
510
550
590
660
790
880
960
1,080
1,190
1,480
1,900
210
360
420
490
570
640
680
760
910
1,020
1,130
1,270
1,410
1,830
2,340
260
440
510
610
710
790
850
940
1,150
1,280
1,430
1,600
1,890
2,430
2,980
300
510
620
740
880
970
1,050
1,190
1,460
1,640
1,940
2,260
2,510
3,110
3,950
Offshore Cable
No.
Instrumentation &
Communication Cable
Max.
overall
dia.
Max.
No. of
wires
VFD Cable
Conductor
Nominal
Area
Technical Information
No. of
Pairs
HV Power Cable
41
Conductor
Nominal
Area
Max.
No. of
wires
Max.
overall
dia.
No.
mm2
EA
mm
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
42
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.4
1.6
mm
7.2
11.4
12.2
13.4
14.9
16.9
16.9
18.1
20.5
21.8
22.8
24.2
26.2
30.0
34.4
7.6
12.2
12.9
14.3
15.9
18.0
18.0
19.3
21.9
23.3
24.3
25.9
28.8
32.0
36.8
8.7
14.1
15.0
16.6
18.5
21.0
21.0
22.6
25.8
28.1
29.4
31.3
33.9
37.6
43.7
9.6
15.7
16.7
18.5
20.7
23.5
23.5
25.3
29.7
31.5
32.9
35.1
38.4
42.6
49.6
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.8
1.9
2.1
2.2
1.2
1.3
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.3
1.2
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.0
2.1
2.2
2.4
2.6
1.2
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.6
2.9
mm
10.9
15.5
16.3
17.7
19.2
21.4
21.4
22.8
25.4
26.7
27.9
29.3
31.5
35.7
40.7
11.5
16.3
17.2
18.6
20.4
22.7
22.7
24.0
26.8
28.4
29.4
31.2
34.3
38.1
43.3
12.6
18.4
19.5
21.1
23.2
25.9
25.9
27.7
31.1
33.6
34.9
37.4
40.2
44.3
50.8
13.5
20.2
21.2
23.2
25.6
28.6
28.6
30.6
35.2
37.6
39.2
41.6
45.1
49.7
57.3
mm
0.6
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.2
1.4
1.5
0.6
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.2
1.3
1.4
1.6
0.7
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
0.7
0.9
0.9
1.0
1.1
1.2
1.2
1.2
1.4
1.4
1.5
1.5
1.7
1.8
2.0
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
220
370
430
510
590
690
740
820
980
1,110
1,230
1,360
1,560
1,990
2,590
240
410
490
580
680
800
860
940
1,130
1,290
1,430
1,600
1,930
2,410
3,060
290
500
610
720
860
1,010
1,080
1,210
1,460
1,760
1,950
2,260
2,590
3,140
4,060
340
610
750
910
1,080
1,270
1,380
1,550
1,970
2,350
2,630
2,940
3,440
4,180
5,480
HV Power Cable
Cable Designation
LV Power & Lighting Cable
Application Standard
- Design guide
- Flame retardant
- Halogen content
- Mud resistant
: UL 1581
Instrumentation &
Communication Cable
250V RFOU(i&c)
Sectional view
Classification
Code
Conductor
Insulation
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Twisting
Individual screen
Construction
(i)
Cabling
Collective screen
(c)
Inner covering
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
Armor
Sheath
(B,C)
U
VFD Cable
Technical Information
Core identification
Offshore Cable
43
Conductor
Nominal
Area
Max.
No. of
wires
Max.
overall
dia.
No.
mm2
EA
mm
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
44
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
mm
10.8
11.4
12.5
14.0
14.5
14.5
15.9
18.1
18.9
19.8
21.3
21.8
25.5
28.5
11.5
12.2
13.3
14.9
15.5
15.5
17.0
19.4
20.2
21.3
22.9
23.4
28.2
30.6
13.2
14.0
15.4
17.3
18.0
18.0
19.8
22.7
23.6
24.9
26.8
28.2
32.9
35.8
14.6
15.5
17.1
19.2
20.0
20.0
22.1
25.3
26.3
28.6
30.7
31.4
36.7
40.3
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.3
1.3
1.4
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.7
1.9
2.0
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.1
1.4
1.4
1.5
1.5
1.6
1.6
1.6
1.8
1.8
1.8
1.9
2.0
2.2
2.3
1.4
1.5
1.5
1.6
1.7
1.7
1.7
1.9
1.9
2.0
2.1
2.1
2.3
2.5
mm
14.9
15.5
16.8
18.3
18.8
18.8
20.4
22.8
23.6
24.5
26.2
26.7
30.8
34.0
15.6
16.3
17.6
19.2
20.0
20.0
21.5
24.1
25.1
26.2
28.0
28.5
33.7
36.7
17.5
18.3
19.9
21.8
22.7
22.7
24.5
27.8
28.7
30.0
32.1
33.7
39.2
42.3
18.9
20.0
21.6
23.9
24.9
24.9
27.0
30.6
31.6
34.1
36.8
37.5
43.2
47.2
mm
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.3
0.8
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
0.8
0.8
0.9
1.0
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.5
1.6
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.7
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
340
390
460
530
570
600
680
810
900
990
1,100
1,210
1,500
1,930
380
440
510
590
660
700
780
930
1,050
1,160
1,300
1,430
1,870
2,370
450
530
630
730
810
870
970
1,180
1,310
1,460
1,630
1,920
2,460
3,020
540
640
760
900
1,010
1,090
1,220
1,490
1,670
1,970
2,290
2,550
3,150
3,990
mm2
EA
mm
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.4
1.6
mm
11.5
12.3
13.5
15.0
17.0
17.0
18.2
20.6
21.9
22.9
24.3
26.3
30.1
34.5
12.3
13.0
14.4
16.0
18.1
18.1
19.4
22.0
23.4
24.4
26.0
28.9
32.1
36.9
14.2
15.1
16.7
18.6
21.1
21.1
22.7
25.9
28.2
29.5
31.4
34.0
37.7
43.8
15.8
16.8
18.6
20.8
23.6
23.6
25.4
29.8
31.6
33.0
35.2
38.5
42.7
49.7
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
1.9
2.1
2.2
1.3
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.2
2.3
1.4
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.0
2.1
2.2
2.4
2.6
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.3
2.4
2.6
2.9
mm
15.6
16.4
17.8
19.5
21.5
21.5
22.9
25.5
26.8
28.0
29.4
31.6
36.2
40.8
16.4
17.3
18.7
20.5
22.8
22.8
24.1
26.9
28.5
29.5
31.3
34.4
38.4
43.4
18.5
19.6
21.2
23.3
26.0
26.0
27.8
31.2
33.7
35.0
37.5
40.3
44.4
50.9
20.3
21.3
23.3
25.7
28.7
28.7
30.7
35.3
37.7
39.3
41.7
45.2
49.8
57.4
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
mm
/km
-km
V/5min.
kg/km
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.2
1.4
1.5
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.2
1.3
1.5
1.6
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.8
0.9
0.9
1.0
1.1
1.2
1.2
1.2
1.4
1.4
1.5
1.6
1.7
1.8
2.0
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
380
450
530
620
710
760
840
1,010
1,130
1,260
1,390
1,590
2,100
2,630
430
510
600
700
820
880
970
1,160
1,320
1,460
1,630
1,960
2,470
3,100
520
630
740
880
1,030
1,110
1,240
1,490
1,790
1,980
2,300
2,630
3,180
4,110
640
770
930
1,110
1,300
1,410
1,580
2,010
2,380
2,670
2,980
3,490
4,230
5,530
Offshore Cable
No.
Instrumentation &
Communication Cable
Max.
overall
dia.
Max.
No. of
wires
VFD Cable
Conductor
Nominal
Area
Technical Information
No. of
Triads
HV Power Cable
45
Application Standard
- Design guide
- Flame retardant
250V BU(c)
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
- Mud resistant
: UL 1581
Construction
Sectional view
Classification
Code
Conductor
Fire resisting layer
Insulation
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Twisting
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad
- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used
Cabling
Collective screen
(c)
Sheath
Core identification
46
Offshore Cable
EA
mm
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.0
1.2
1.2
1.2
1.3
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.6
1.7
1.9
1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
2.0
1.1
1.3
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.2
1.1
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.3
Overall diameter
Nominal
Tolerance
mm
mm
7.6
11.6
12.4
13.2
15.0
16.0
16.0
17.2
19.5
20.3
21.1
22.8
23.9
27.2
31.4
8.0
12.3
13.2
14.2
15.9
17.2
17.2
18.3
20.8
21.6
22.6
24.3
25.6
29.4
33.7
9.2
14.2
15.2
16.2
18.4
19.9
19.9
21.2
24.1
25.3
26.2
28.4
29.9
34.3
39.3
10.0
15.6
16.9
18.0
20.4
21.9
21.9
23.6
26.7
28.1
29.4
31.8
33.5
38.1
43.7
0.5
0.6
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.2
0.5
0.7
0.7
0.7
0.8
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
0.6
0.7
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.5
0.6
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.3
1.3
1.4
1.6
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
90
170
200
240
290
330
360
410
500
570
630
720
820
1,020
1,360
100
190
230
280
340
390
430
470
580
660
760
850
980
1,240
1,620
130
240
300
360
440
520
560
630
770
900
1,010
1,150
1,330
1,680
2,190
160
300
390
470
580
660
730
830
1,030
1,200
1,370
1,560
1,810
2,250
2,940
Offshore Cable
mm2
Thickness
of
Insulation
Instrumentation &
Communication Cable
Max.
overall
dia.
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
Max.
No. of
wires
VFD Cable
No.
Conductor
Nominal
Area
Technical Information
No. of
Pairs
HV Power Cable
250V BU(c)
47
No.
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
48
Conductor
Nominal
Area
Max.
No. of
wires
mm2
EA
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Offshore Cable
Max.
overall
dia.
mm
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
Insulation
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.8
2.0
2.1
1.1
1.2
1.3
1.3
1.4
1.5
1.5
1.5
1.7
1.7
1.8
1.8
1.9
2.1
2.3
1.1
1.4
1.4
1.5
1.6
1.7
1.7
1.7
1.9
1.9
2.0
2.1
2.2
2.3
2.6
1.1
1.4
1.4
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.1
2.1
2.3
2.4
2.7
Overall diameter
Nominal
Tolerance
mm
mm
8.0
12.7
13.5
15.0
16.5
18.8
18.8
20.3
23.1
24.4
25.6
27.2
29.7
33.2
38.1
8.7
13.6
14.6
16.0
17.9
20.4
20.4
21.8
25.0
26.4
27.8
29.7
32.2
35.9
41.4
9.8
17.1
18.1
20.0
22.2
25.0
25.0
26.7
30.7
32.3
33.9
36.5
39.4
43.6
50.2
10.6
17.3
18.4
20.5
22.9
26.1
26.1
28.1
32.2
34.3
36.0
38.2
41.6
46.2
53.5
0.5
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.4
0.6
0.7
0.7
0.8
0.8
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.5
0.6
0.8
0.8
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
0.6
0.8
0.9
0.9
1.0
1.1
1.1
1.1
1.3
1.3
1.4
1.4
1.5
1.7
1.9
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
110
200
250
320
380
460
500
570
700
800
920
1,020
1,220
1,520
1,960
130
230
300
370
450
540
600
660
830
960
1,090
1,240
1,450
1,810
2,360
160
330
410
520
630
750
820
920
1,170
1,330
1,520
1,730
2,020
2,480
3,260
200
390
510
650
790
950
1,050
1,200
1,500
1,750
2,010
2,250
2,660
3,290
4,340
HV Power Cable
250V BU(i)
Application Standard
- Design guide
- Flame retardant
IEC 60331-1,-2(120min)
- Halogen content
- Mud resistant
: UL 1581
Instrumentation &
Communication Cable
250V BU(i)
- Fire resistance
Sectional view
Classification
Code
Conductor
Fire resisting layer
Insulation
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Twisting
Individual screen
Construction
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
Cabling
Sheath
VFD Cable
Technical Information
Offshore Cable
49
No.
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
50
Conductor
Nominal
Area
Max.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
Insulation
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.0
1.2
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.8
1.9
1.0
1.2
1.2
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.7
1.9
2.0
1.1
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
1.9
2.1
2.2
1.1
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.0
2.3
2.4
Overall diameter
Nominal
Tolerance
mm
mm
7.6
12.3
13.0
14.5
16.1
16.9
16.9
18.5
21.2
22.2
23.3
25.2
25.7
30.2
32.9
8.0
13.0
13.8
15.3
17.3
17.9
17.9
19.8
22.7
23.6
24.9
26.7
27.3
32.3
35.2
9.2
15.0
15.9
17.6
19.9
20.6
20.6
22.8
26.1
27.2
28.7
31.2
31.9
37.5
40.8
10.0
16.4
17.6
19.5
21.8
22.8
22.8
25.3
29.1
30.5
32.0
34.5
35.3
41.7
45.3
0.5
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
0.5
0.7
0.7
0.8
0.8
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.1
1.3
1.4
0.6
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.5
0.6
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.6
1.7
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
90
180
230
290
340
400
430
490
610
710
800
910
1,030
1,320
1,680
100
200
260
330
410
460
510
590
730
830
960
1,070
1,230
1,580
2,030
130
260
330
420
520
590
650
750
930
1,070
1,230
1,420
1,620
2,060
2,630
160
320
430
540
660
770
850
980
1,230
1,440
1,640
1,860
2,130
2,740
3,510
EA
mm
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.0
1.2
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.2
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.3
1.1
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.3
2.6
1.1
1.4
1.4
1.5
1.6
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.3
2.5
2.8
Overall diameter
Nominal
Tolerance
mm
mm
8.0
13.1
14.1
15.5
17.3
19.7
19.7
21.1
24.0
25.6
26.7
28.6
31.2
34.6
40.0
8.7
14.2
15.1
16.8
18.5
21.1
21.1
22.8
26.0
27.7
29.0
31.0
33.6
37.4
43.1
9.8
16.1
17.4
19.1
21.4
24.4
24.4
26.3
30.2
32.1
33.7
36.0
39.0
43.4
50.2
10.6
17.7
18.9
21.0
23.5
26.8
26.8
29.1
33.4
35.3
37.1
39.6
42.9
47.9
55.4
0.5
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.5
0.6
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.6
0.6
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
0.6
0.8
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.7
2.0
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
110
220
290
350
430
520
580
640
800
940
1,060
1,200
1,430
1,770
2,320
130
260
330
420
510
610
680
770
960
1,130
1,290
1,470
1,720
2,130
2,790
160
320
430
530
660
790
880
1,000
1,260
1,480
1,700
1,930
2,260
2,790
3,700
200
410
550
700
860
1,040
1,160
1,340
1,680
1,950
2,240
2,550
2,990
3,740
4,940
Offshore Cable
mm2
Thickness
of
Insulation
Instrumentation &
Communication Cable
Max.
overall
dia.
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
Max.
No. of
wires
VFD Cable
No.
Conductor
Nominal
Area
Technical Information
No. of
Triads
HV Power Cable
250V BU(i)
51
Cable Designation
250V BU(i&c)
Application Standard
- Design guide
- Flame retardant
250V BU(i&c)
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
- Mud resistant
: UL 1581
Construction
Sectional view
Classification
Code
Conductor
Fire resisting layer
Insulation
Twisting
Individual screen
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
Cabling
Collective screen
(c)
Sheath
Core identification
52
Offshore Cable
EA
mm
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.2
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.9
2.0
1.2
1.3
1.3
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.7
1.8
1.9
2.0
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
1.9
2.1
2.2
1.3
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.0
2.3
2.4
Overall diameter
Nominal
Tolerance
mm
mm
12.4
13.1
14.6
16.2
17.0
17.0
18.6
21.3
22.3
23.4
25.3
25.8
30.5
33.2
13.1
14.1
15.4
17.4
18.0
18.0
19.9
22.8
23.7
25.0
26.8
27.6
32.4
35.3
15.1
16.0
17.7
20.0
20.7
20.7
22.9
26.2
27.3
29.0
31.3
32.0
37.6
40.9
16.5
17.7
19.6
21.9
22.9
22.9
25.4
29.2
30.6
32.1
34.6
35.4
41.8
45.4
0.7
0.7
0.7
0.8
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
0.7
0.7
0.8
0.8
0.8
0.8
0.9
1.0
1.0
1.1
1.1
1.1
1.3
1.4
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.5
0.8
0.8
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.4
1.6
1.7
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
190
240
300
360
410
450
510
630
730
820
940
1,060
1,370
1,740
220
290
350
430
480
530
610
750
860
980
1,100
1,270
1,620
2,060
280
350
440
540
610
670
770
960
1,100
1,280
1,450
1,650
2,090
2,670
340
450
570
680
790
880
1,010
1,270
1,480
1,670
1,900
2,170
2,780
3,560
Offshore Cable
mm2
Thickness
of
Insulation
Instrumentation &
Communication Cable
Max.
overall
dia.
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
Max.
No. of
wires
VFD Cable
No.
Conductor
Nominal
Area
Technical Information
No. of
Pairs
HV Power Cable
250V BU(i&c)
53
No.
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
54
Conductor
Nominal
Area
Max.
No. of
wires
mm2
EA
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
Offshore Cable
Max.
overall
dia.
mm
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
Thickness
of
Insulation
Thickness
of
sheath
mm
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
1.2
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
2.0
2.2
1.3
1.3
1.4
1.4
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.3
1.3
1.4
1.4
1.5
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.2
2.3
2.6
1.4
1.4
1.5
1.6
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.3
2.5
2.8
Overall diameter
Nominal
Tolerance
mm
mm
13.2
14.2
15.6
17.4
19.8
19.8
21.2
24.1
25.7
26.8
28.7
31.3
34.7
40.1
14.3
15.2
16.9
18.6
21.2
21.2
22.9
26.1
27.8
29.1
31.1
33.7
37.5
43.2
16.2
17.5
19.2
21.5
24.5
24.5
26.4
30.5
32.2
33.8
36.1
39.1
43.5
50.3
17.8
19.0
21.1
23.6
26.9
26.9
29.2
33.5
35.4
37.2
39.7
43.0
48.0
55.5
0.7
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.5
0.7
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.6
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.3
1.3
1.4
1.5
1.6
1.8
0.8
0.9
0.9
1.0
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.7
2.0
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
310
380
460
550
650
700
780
950
1,100
1,220
1,380
1,610
2,050
2,630
280
350
440
530
640
700
800
990
1,160
1,320
1,500
1,760
2,160
2,830
340
450
560
680
820
910
1,030
1,310
1,510
1,730
1,960
2,300
2,830
3,740
440
570
730
890
1,070
1,190
1,370
1,720
1,990
2,280
2,590
3,030
3,780
4,990
HV Power Cable
Application Standard
- Design guide
- Flame retardant
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
- Mud resistant
: UL 1581
Instrumentation &
Communication Cable
250V BFOU(c)
Sectional view
Classification
Code
Conductor
Fire resisting layer
Insulation
Construction
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
B
Twisting
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad
- Twisted pairs / triads shall be cabled
- Flame retardant & non-hygroscopic fillers may be used
Cabling
Collective screen
(c)
Inner covering
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
Armor
Sheath
(B,C)
U
VFD Cable
Technical Information
Core identification
Offshore Cable
55
Conductor
Nominal
Area
Max.
No. of
wires
Max.
overall
dia.
No.
mm2
EA
mm
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
56
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
mm
7.4
11.0
11.8
12.6
14.2
15.2
15.2
16.2
18.3
19.1
19.9
21.4
22.5
25.6
30.0
7.8
11.7
12.6
13.4
15.1
16.2
16.2
17.3
19.6
20.4
21.2
22.9
24.0
28.2
32.1
8.8
13.4
14.4
15.4
17.4
18.7
18.7
20.0
22.7
23.7
24.6
26.6
28.7
32.7
37.3
9.6
14.8
15.9
17.0
19.2
20.7
20.7
22.2
25.1
26.3
28.2
30.4
31.9
36.3
41.9
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.1
1.3
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.6
1.6
1.7
1.8
1.9
2.1
1.2
1.3
1.4
1.4
1.5
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.8
2.0
2.2
1.2
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.8
1.9
2.0
2.2
2.4
1.2
1.4
1.5
1.5
1.6
1.7
1.7
1.7
1.9
1.9
2.0
2.1
2.1
2.3
2.5
mm
11.1
15.1
15.9
16.9
18.5
19.7
19.7
20.7
23.0
23.8
24.6
26.3
27.6
30.9
35.7
11.7
15.8
16.9
17.7
19.6
20.7
20.7
21.8
24.3
25.3
26.1
28.0
29.1
33.7
38.4
12.7
17.7
18.7
19.9
21.9
23.4
23.4
24.9
27.8
28.8
29.7
31.9
34.2
39.0
44.0
13.5
19.1
20.4
21.5
23.9
25.6
25.6
27.1
30.4
31.6
33.7
36.5
38.0
42.8
48.8
mm
0.6
0.8
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.4
0.7
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.1
1.2
1.3
1.5
0.7
0.8
0.9
0.9
1.0
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.3
1.5
1.6
0.7
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.8
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
210
340
390
440
510
570
600
650
770
850
920
1,030
1,150
1,390
1,840
240
370
430
490
570
630
670
730
870
970
1,060
1,180
1,310
1,700
2,220
270
450
520
600
700
790
840
930
1,110
1,230
1,350
1,510
1,800
2,290
2,870
320
520
630
720
860
970
1,040
1,150
1,390
1,560
1,830
2,130
2,390
2,920
3,750
mm2
EA
mm
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.4
1.6
mm
7.8
12.1
12.9
14.2
15.7
17.8
17.8
19.1
21.7
23.0
24.0
25.6
28.5
31.6
36.3
8.3
13.0
13.8
15.2
16.9
19.2
19.2
20.6
23.4
24.8
26.0
28.5
30.8
34.1
39.6
9.4
14.9
15.9
17.6
19.6
22.2
22.2
23.9
28.1
29.7
31.1
33.1
35.8
40.2
46.2
10.2
16.3
17.4
19.3
21.5
24.5
24.5
26.3
30.8
32.7
34.2
36.4
39.8
44.2
51.5
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.2
1.3
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.3
1.2
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.8
1.9
2.0
2.1
2.2
2.5
1.2
1.4
1.5
1.6
1.6
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.3
2.5
2.7
1.3
1.5
1.5
1.6
1.7
1.8
1.8
1.9
2.1
2.2
2.2
2.3
2.5
2.6
2.9
mm
11.7
16.2
17.2
18.5
20.2
22.5
22.5
23.8
26.6
28.1
29.1
30.9
34.0
37.7
42.8
12.2
17.3
18.1
19.7
21.4
23.9
23.9
25.5
28.5
29.9
31.3
34.0
36.9
40.4
46.5
13.3
19.2
20.4
22.3
24.3
27.1
27.1
29.0
33.6
35.2
37.2
39.4
42.3
47.1
53.5
14.3
20.8
21.9
24.0
26.4
29.6
29.6
31.6
36.9
39.0
40.5
42.9
46.7
51.3
59.2
mm
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.6
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.1
1.2
1.2
1.2
1.3
1.4
1.5
1.7
0.7
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.3
1.4
1.4
1.5
1.6
1.7
1.9
0.7
0.9
1.0
1.0
1.1
1.2
1.2
1.2
1.4
1.5
1.5
1.6
1.7
1.8
2.1
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
240
390
460
540
620
730
770
850
1,010
1,140
1,250
1,390
1,680
2,090
2,620
270
440
510
610
700
820
870
970
1,160
1,300
1,450
1,710
2,030
2,420
3,130
310
530
640
760
880
1,030
1,100
1,230
1,590
1,780
2,070
2,300
2,620
3,230
4,070
370
640
770
930
1,100
1,290
1,390
1,560
2,080
2,360
2,620
2,920
3,430
4,130
5,400
Offshore Cable
No.
Instrumentation &
Communication Cable
Max.
overall
dia.
Max.
No. of
wires
VFD Cable
Conductor
Nominal
Area
Technical Information
No. of
Triads
HV Power Cable
57
Application Standard
- Design guide
- Flame retardant
250V BFOU(i)
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
- Mud resistant
: UL 1581
Construction
Sectional view
Classification
Code
Conductor
Fire resisting layer
Insulation
Twisting
Individual screen
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
Cabling
Inner covering
Armor
Sheath
- Braid of tinned copper wire (O) / bronze wire (B) /galvanized steel wire (C)
(B,C)
U
Core identification
58
Offshore Cable
mm2
EA
mm
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
1P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
mm
7.4
11.7
12.4
13.7
15.3
15.9
15.9
17.5
20.0
20.8
21.9
23.6
24.1
29.0
31.5
7.8
12.4
13.2
14.5
16.3
16.9
16.9
18.6
21.3
22.2
23.3
25.1
25.7
30.9
33.6
8.8
14.2
15.1
16.6
18.7
19.4
19.4
21.4
24.5
25.6
26.9
29.8
30.5
35.7
39.2
9.6
15.6
16.6
18.3
20.6
21.4
21.4
23.7
27.9
29.1
30.6
32.9
33.7
39.9
43.3
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.1
1.3
1.3
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.7
1.8
1.8
2.0
2.1
1.2
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
1.9
2.1
2.2
1.2
1.4
1.5
1.5
1.6
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.1
2.3
2.4
1.2
1.5
1.5
1.6
1.7
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.2
2.5
2.6
mm
11.1
15.8
16.5
18.0
19.8
20.4
20.4
22.2
24.9
25.7
26.8
28.7
29.2
34.5
37.6
11.7
16.5
17.5
18.8
20.8
21.4
21.4
23.3
26.2
27.1
28.4
30.4
31.0
37.0
39.9
12.7
18.5
19.6
21.1
23.4
24.1
24.1
26.3
29.6
30.9
32.2
35.3
36.6
42.2
45.9
13.5
20.1
21.1
23.0
25.5
26.3
26.3
28.8
33.4
34.6
36.7
39.2
40.0
46.8
50.4
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
mm
/km
-km
V/5min.
kg/km
0.6
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.0
1.1
1.1
1.2
1.2
1.3
1.4
0.7
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.2
1.4
1.5
0.7
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.7
0.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.5
1.7
1.8
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
220
360
420
490
580
630
670
760
910
1,000
1,110
1,240
1,370
1,790
2,280
240
400
470
550
650
710
760
860
1,030
1,150
1,280
1,440
1,600
2,170
2,650
280
480
570
670
790
870
930
1,050
1,270
1,440
1,590
1,880
2,190
2,710
3,390
320
560
670
810
970
1,070
1,160
1,310
1,690
1,900
2,210
2,480
2,760
3,510
4,340
Offshore Cable
No.
Instrumentation &
Communication Cable
Max.
overall
dia.
Max.
No. of
wires
VFD Cable
Conductor
Nominal
Area
Technical Information
No. of
Pairs
HV Power Cable
59
Conductor
Nominal
Area
Max.
No. of
wires
Max.
overall
dia.
No.
mm2
EA
mm
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
1T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
60
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.6
mm
7.8
12.5
13.3
14.7
16.3
18.5
18.5
19.9
22.6
24.0
25.1
26.8
29.8
33.0
38.4
8.3
13.4
14.3
15.8
17.5
19.9
19.9
21.4
24.4
25.9
27.0
29.6
32.0
35.6
41.3
9.4
15.3
16.4
18.1
20.2
23.0
23.0
24.7
29.0
30.7
32.1
34.2
37.0
41.6
47.8
10.2
16.7
17.9
19.8
22.1
25.2
25.2
27.9
31.8
33.7
35.3
37.6
41.1
45.7
53.2
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.2
1.4
1.4
1.4
1.5
1.6
1.6
1.6
1.8
1.8
1.9
1.9
2.0
2.2
2.4
1.2
1.4
1.4
1.5
1.6
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.1
2.3
2.5
1.2
1.5
1.5
1.6
1.7
1.8
1.8
1.8
2.0
2.1
2.2
2.2
2.3
2.5
2.8
1.3
1.5
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.7
3.0
mm
11.7
16.8
17.6
19.0
20.8
23.2
23.2
24.6
27.7
29.1
30.4
32.1
35.3
39.3
45.1
12.2
17.7
18.6
20.3
22.2
24.6
24.6
26.3
29.5
31.2
32.3
35.1
38.1
42.1
48.2
13.3
19.8
20.9
22.8
25.1
28.1
28.1
29.8
34.5
36.8
38.4
40.5
43.5
48.5
55.3
14.3
21.2
22.6
24.5
27.0
30.5
30.5
33.4
37.9
40.0
41.8
44.3
48.0
53.0
61.1
mm
0.7
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.7
0.7
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.7
0.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.5
1.5
1.6
1.8
2.0
0.7
0.9
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.6
1.7
1.9
2.1
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
240
420
490
570
680
790
840
930
1,130
1,270
1,420
1,570
1,900
2,380
3,080
270
460
550
660
780
900
960
1,080
1,300
1,480
1,640
1,930
2,300
2,780
3,590
310
560
670
810
960
1,130
1,220
1,350
1,730
2,060
2,300
2,540
2,910
3,600
4,590
370
660
820
990
1,180
1,400
1,520
1,800
2,260
2,580
2,890
3,230
3,780
4,600
6,020
HV Power Cable
Cable Designation
LV Power & Lighting Cable
Application Standard
- Design guide
- Flame retardant
IEC 60331-1,-2(120min)
- Halogen content
- Mud resistant
: UL 1581
Instrumentation &
Communication Cable
250V BFOU(i&c)
- Fire resistance
Sectional view
Classification
Code
Conductor
Fire resisting layer
Insulation
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Twisting
Individual screen
Construction
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Two/Three Insulated cores shall be twisted together to form a pair/Triad
(i)
Cabling
VFD Cable
(c)
Inner covering
- Braid of tinned copper wire (O) / bronze wire (B) / galvanized steel wire (C)
Armor
Sheath
(B,C)
U
Technical Information
Offshore Cable
61
Conductor
Nominal
Area
Max.
No. of
wires
Max.
overall
dia.
No.
mm2
EA
mm
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
2P
3P
4P
5P
6P
7P
8P
10P
12P
14P
16P
19P
24P
32P
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
62
Offshore Cable
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
mm
11.8
12.5
13.8
15.4
16.0
16.0
17.6
20.1
20.9
22.0
23.7
24.2
29.1
31.6
12.5
13.3
14.6
16.4
17.0
17.0
18.7
21.4
22.3
23.4
25.2
25.8
31.0
33.7
14.3
15.2
16.7
18.8
19.5
19.5
21.5
24.6
25.7
27.0
29.9
30.6
35.8
39.3
15.7
16.7
18.4
20.7
21.5
21.5
23.8
28.0
29.2
30.7
33.0
33.8
40.0
43.4
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.3
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.7
1.8
1.8
2.0
2.1
1.4
1.4
1.4
1.5
1.5
1.5
1.6
1.7
1.7
1.8
1.9
1.9
2.1
2.2
1.4
1.5
1.5
1.6
1.6
1.6
1.7
1.8
1.9
1.9
2.0
2.1
2.3
2.4
1.5
1.5
1.6
1.7
1.7
1.7
1.8
2.0
2.0
2.1
2.2
2.2
2.5
2.6
mm
15.9
16.8
18.1
19.9
20.5
20.5
22.3
25.0
25.8
26.9
28.8
29.3
34.6
37.7
16.8
17.6
18.9
20.9
21.5
21.5
23.4
26.3
27.2
28.5
30.5
31.1
37.1
40.0
18.6
19.7
21.2
23.5
24.2
24.2
26.4
29.7
31.0
32.3
35.4
36.7
42.3
46.0
20.2
21.2
23.1
25.6
26.4
26.4
28.9
33.5
34.7
36.8
39.3
40.1
46.9
50.5
mm
0.8
0.8
0.8
0.9
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.2
1.3
1.4
0.8
0.8
0.9
0.9
0.9
0.9
1.0
1.1
1.1
1.2
1.2
1.2
1.4
1.5
0.9
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.4
1.6
1.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.3
1.4
1.5
1.5
1.7
1.8
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
380
440
510
600
650
690
780
930
1,030
1,130
1,270
1,400
1,820
2,310
420
490
570
670
730
780
880
1,060
1,170
1,310
1,470
1,630
2,200
2,690
500
590
690
810
890
950
1,080
1,300
1,470
1,630
1,920
2,230
2,750
3,440
590
700
840
990
1,100
1,180
1,340
1,720
1,930
2,250
2,520
2,800
3,550
4,390
mm2
EA
mm
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
2T
3T
4T
5T
6T
7T
8T
10T
12T
14T
16T
19T
24T
32T
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
1.7
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
mm
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
mm
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.6
mm
12.6
13.4
14.8
16.4
18.6
18.6
20.0
22.7
24.1
25.2
26.9
29.9
33.1
38.5
13.5
14.4
15.9
17.6
20.0
20.0
21.5
24.5
26.0
27.9
29.7
32.1
35.7
41.4
15.4
16.5
18.2
20.3
23.1
23.1
24.8
29.1
30.8
32.2
34.3
37.1
41.7
47.9
16.8
18.0
19.9
22.2
25.3
25.3
28.0
31.9
33.8
35.4
37.7
41.2
45.8
53.3
Dia. of
wire for
armour
mm
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4
0.4
0.4
0.4
0.4
0.4
0.4
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
1.4
1.4
1.4
1.5
1.6
1.6
1.7
1.8
1.8
1.9
1.9
2.0
2.2
2.4
1.4
1.4
1.5
1.6
1.7
1.7
1.7
1.8
1.9
2.0
2.0
2.2
2.3
2.5
1.5
1.5
1.6
1.7
1.8
1.8
1.8
2.0
2.1
2.2
2.2
2.4
2.5
2.8
1.5
1.6
1.6
1.7
1.9
1.9
2.0
2.1
2.2
2.3
2.4
2.5
2.7
3.0
mm
16.9
17.7
19.1
20.9
23.3
23.3
24.9
27.8
29.2
30.5
32.2
35.4
39.4
45.2
17.8
18.7
20.4
22.3
24.9
24.9
26.4
29.6
31.3
33.4
35.2
38.4
42.2
48.3
19.9
21.0
22.9
25.2
28.2
28.2
29.9
34.6
36.9
38.5
40.6
43.8
48.6
55.4
21.3
22.7
24.6
27.1
30.6
30.6
33.5
38.0
40.1
41.9
44.4
48.1
53.1
61.2
mm
0.8
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.7
0.8
0.9
0.9
1.0
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.7
0.9
0.9
1.0
1.1
1.1
1.1
1.2
1.3
1.4
1.5
1.5
1.6
1.8
2.0
0.9
1.0
1.0
1.1
1.2
1.2
1.3
1.4
1.5
1.6
1.6
1.7
1.9
2.1
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
Approx.
/km
-km
V/5min.
kg/km
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
26.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
19.3
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
12.9
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
8.02
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,170
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,050
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
1,020
850
850
850
850
850
850
850
850
850
850
850
850
850
850
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
430
510
590
690
810
870
970
1,160
1,300
1,450
1,600
1,930
2,420
3,110
480
570
680
800
940
1,000
1,110
1,330
1,510
1,780
1,960
2,350
2,820
3,630
580
690
830
990
1,160
1,250
1,380
1,770
2,090
2,330
2,580
2,970
3,640
4,640
680
850
1,010
1,200
1,430
1,560
1,830
2,290
2,620
2,930
3,270
3,830
4,650
6,080
Offshore Cable
No.
Instrumentation &
Communication Cable
Max.
overall
dia.
Max.
No. of
wires
VFD Cable
Conductor
Nominal
Area
Technical Information
No. of
Triads
HV Power Cable
63
0.6/1kV UX, FX - UX
0.6/1kV RX
65 ~ 66
HV Power Cable
0.6/1kV UX, FX - UX , RX
Application Standard
- Design guide
- Flame retardant
- Halogen content
: UL 1581
Instrumentation &
Communication Cable
0.6/1KV RX
Construction
Classification
Code
Construction detail
Conductor
Insulation
RX
UX
Sectional view
No.
Conductor
Nominal
Area
Min.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
7
7
7
7
7
7
7
7
7
19
19
19
37
37
37
61
61
1.4
1.7
2.2
2.7
3.3
4.2
5.3
6.6
7.9
9.1
11.0
12.9
14.5
16.2
18.0
20.6
23.1
Thickness
of
Insulation
mm
2.0
2.0
2.0
2.0
2.0
2.0
2.1
2.4
2.4
2.7
3.0
3.0
3.1
3.4
3.7
4.0
4.3
Overall diameter
Nominal
Tolerance
mm
mm
5.5
5.8
6.2
6.7
7.3
8.2
9.4
11.3
12.4
14.4
16.7
18.6
20.3
22.4
24.9
28.1
31.0
0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.8
0.8
0.9
1.0
1.0
1.1
1.2
1.3
1.4
1.5
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
/km
-km
V/5min.
kg/km
18.2
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
22
20
18
15
13
11
10
9
8
8
7
6
6
6
6
5
5
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
3,500
50
58
71
89
114
160
230
350
450
600
840
1,110
1,360
1,660
2,080
2,690
3,330
Offshore Cable
Technical Information
No. of
Cores
VFD Cable
65
No.
Conductor
Nominal
Area
Min.
No. of
wires
Max.
overall
dia.
mm2
EA
mm
1.0
0.21
Thickness
of
Insulation
mm
1.5
Overall diameter
Nominal
Tolerance
mm
mm
2.0
5.5
0.5
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
/km
-km
V/5min.
kg/km
20.0
22
3,500
50
1.5
0.26
1.8
2.0
5.8
0.5
13.7
20
3,500
58
2.5
0.26
2.4
2.0
6.3
0.6
8.21
17
3,500
72
0.31
3.0
2.0
6.8
0.6
5.09
15
3,500
91
0.31
3.9
2.0
7.4
0.6
3.39
13
3,500
115
10
0.41
5.1
2.0
8.3
0.6
1.95
11
3,500
160
16
0.41
6.3
2.1
10.0
0.7
1.24
3,500
230
25
0.41
7.8
2.4
12.1
0.8
0.795
3,500
340
35
0.41
9.2
2.4
13.3
0.8
0.565
3,500
450
50
0.41
11.0
2.7
15.5
0.9
0.393
3,500
630
70
0.51
13.1
3.0
18.0
1.0
0.277
3,500
880
95
0.51
15.1
3.1
19.9
1.1
0.210
3,500
1,110
120
0.51
17.0
3.1
21.7
1.2
0.164
3,500
1,370
150
0.51
19.0
3.4
24.1
1.3
0.132
3,500
1,710
185
0.51
21.0
3.7
26.2
1.3
0.108
3,500
2,060
240
0.51
24.0
4.0
29.5
1.5
0.0817
3,500
2,680
300
0.51
27.0
4.3
32.7
1.6
0.0654
3,500
3,360
Conductor
Resistance
(at 20)
(Max.)
Insulation
Resistance
(at 20)
(Min.)
Test
Voltage
Cable
Weight
/km
-km
V/5min.
kg/km
0.6/1kV RX
No. of
Cores
No.
66
Conductor
Nominal
Area
Min.
No. of
wires
mm2
EA
Max.
overall
dia.
mm
Thickness
of
Insulation
mm
Overall diameter
Nominal
Tolerance
mm
mm
1.0
1.4
2.0
5.5
0.5
18.2
22
3,500
47
1.5
1.7
2.0
5.8
0.5
12.2
20
3,500
54
2.5
2.2
2.0
6.2
0.5
7.56
18
3,500
67
2.7
2.0
6.7
0.6
4.70
15
3,500
85
3.3
2.0
7.3
0.6
3.11
13
3,500
109
10
4.2
2.0
8.2
0.6
1.84
11
3,500
150
16
5.3
2.1
9.4
0.7
1.16
10
3,500
220
25
6.6
2.3
11.1
0.7
0.734
3,500
330
35
7.9
2.4
12.4
0.8
0.529
3,500
440
50
19
9.1
2.7
14.4
0.9
0.391
3,500
590
70
19
11.0
2.9
16.5
1.0
0.270
3,500
810
95
19
12.9
3.0
18.6
1.0
0.195
3,500
1,090
120
37
14.5
3.1
20.3
1.1
0.154
3,500
1,340
150
37
16.2
3.4
22.4
1.2
0.126
3,500
1,630
185
37
18.0
3.7
24.9
1.3
0.100
3,500
203
240
61
20.6
4.0
28.1
1.4
0.0762
3,500
2,640
300
61
23.1
4.3
31.0
1.5
0.0607
3,500
3,270
Offshore Cable
VFD Cable
68 ~ 69
70 ~ 71
VFD Cable
Cable Designation
0.6/1kV(1.8/3kV) RFOU(VFD), FX-RFOU(VFD)
Application Standard
- Design guide
- Flame retardant
0.6/1kV(1.8/3kV)
RFOU(VFD)
- Halogen content
- Mud resistant
: UL 1581
Construction
Sectional view
Classification
Code
Conductor
Insulation
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
Cabling
Inner covering
F
(VFD)
Armor (Screen)
Sheath
Core identification
Note. 1. Flexible cable (Class5 Conductor) can be supplied
68
Offshore Cable
VFD Cable
0.6/1kV(1.8/3kV) RFOU(VFD)
mm2
25
6
35
6
50
10
70
16
95
16
120
25
150
25
185
35
240
50
ea.
7
7
7
7
19
7
19
7
19
7
37
7
37
7
37
7
61
19
mm
6.6
3.3
7.9
3.3
9.1
4.2
11.0
5.3
12.9
5.3
14.5
6.6
16.2
6.6
18.0
7.9
20.6
9.1
2.2
1.0
2.2
1.0
2.2
1.0
2.2
1.0
2.4
1.0
2.4
1.2
2.4
1.2
2.4
1.2
2.4
1.4
mm
mm
Dia. of
wire for
armour
mm
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
mm
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
mm
/km
-km
V/5min.
kg/km
1.0
25.7
0.3
1.9
31.7
1.6
28.7
0.3
2.0
34.9
1.7
1.2
31.5
0.4
2.2
38.5
1.8
1.2
35.4
0.4
2.3
42.6
2.0
1.4
40.7
0.4
2.5
48.3
2.2
1.4
44.2
0.4
2.7
52.2
2.4
1.4
47.6
0.4
2.8
55.8
2.5
1.6
51.9
0.4
3.0
60.5
2.7
1.6
57.7
0.4
3.2
66.7
3.0
830
790
730
790
640
640
550
530
510
530
460
510
420
510
380
440
340
440
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
1,970
1.2
0.734
3.110
0.529
3.110
0.391
1.840
0.270
1.160
0.195
1.160
0.154
0.734
0.126
0.734
0.1000
0.5290
0.0762
0.3910
HV Power Cable
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
Max.
Dia.
2,420
3,160
4,150
No.
Conductor
Nominal
Min.
Area
Number of
wires
5,330
6,540
7,590
9,230
11,690
Instrumentation &
Communication Cable
No. of
Cores
0.6/1kV(1.8/3kV) FX-RFOU(VFD)
mm2
25
6
35
6
50
10
70
16
95
16
120
25
150
25
185
35
240
50
Max.
overall
dia.
mm
mm
0.41
0.31
0.41
0.31
0.41
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41
7.8
3.9
9.2
3.9
11.0
5.1
13.1
6.3
15.1
6.3
17.0
7.8
19.0
7.8
21.0
9.2
24.0
11.0
2.2
1.0
2.2
1.0
2.2
1.0
2.2
1.0
2.4
1.0
2.4
1.2
2.4
1.2
2.4
1.2
2.4
1.4
mm
mm
Dia. of
wire for
armour
mm
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
mm
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
mm
/km
-km
V/5min.
kg/km
1.2
28.3
0.3
2.0
34.5
1.7
31.3
0.4
2.1
38.1
1.8
1.2
34.7
0.4
2.3
41.9
2.0
1.4
39.2
0.4
2.5
46.8
2.2
1.4
44.0
0.4
2.7
52.0
2.4
1.4
47.8
0.4
2.8
56.0
2.5
1.6
52.1
0.4
3.0
60.7
2.7
1.6
56.2
0.4
3.1
65.0
2.9
1.6
63.1
0.4
3.4
72.5
3.2
750
790
650
790
570
630
490
470
470
470
420
450
380
450
350
390
310
380
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
2,140
1.2
0.795
3.390
0.565
3.390
0.393
1.950
0.277
1.240
0.210
1.240
0.164
0.795
0.132
0.795
0.108
0.565
0.0817
0.393
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
Max.
dia. of
wires
2,710
3,520
4,550
5,640
6,880
8,120
VFD Cable
No.
Conductor
Nominal
Area
9,620
12,390
Technical Information
No. of
Cores
Offshore Cable
69
VFD Cable
Cable Designation
0.6/1kV(1.8/3kV) BFOU(VFD), FX-BFOU(VFD)
Application Standard
- Design guide
- Flame retardant
0.6/1kV(1.8/3kV)
BFOU(VFD)
- Fire resistance
: IEC 60331-21(90min)
IEC 60331-1,-2(120min)
- Halogen content
- Mud resistant
: UL 1581
Construction
Sectional view
Classification
Code
Conductor
Fire resisting layer
Insulation
Construction detail
- Stranded tinned annealed copper wires as per IEC 60228, Class 2
- Mica/glass tape
- HF EPR as per IEC 60092-351
- Insulated cores shall be cabled
- Flame retardant & non-hygroscopic fillers may be used
Cabling
Inner covering
F
(VFD)
Armor (Screen)
Sheath
Core identification
Note. 1. Flexible cable (Class5 Conductor) can be supplied
70
Offshore Cable
VFD Cable
0.6/1kV(1.8/3kV) BFOU(VFD)
mm2
25
6
35
6
50
10
70
16
95
16
120
25
150
25
185
35
240
50
ea.
7
7
7
7
19
7
19
7
19
7
37
7
37
7
37
7
61
19
mm
6.6
3.3
7.9
3.3
9.1
4.2
11.0
5.3
12.9
5.3
14.5
6.6
16.2
6.6
18.0
7.9
20.6
9.1
2.2
1.0
2.2
1.0
2.2
1.0
2.2
1.0
2.4
1.0
2.4
1.2
2.4
1.2
2.4
1.2
2.4
1.4
mm
mm
Dia. of
wire for
armour
mm
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
mm
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
mm
/km
-km
V/5min.
kg/km
1.0
26.8
0.3
2.0
33.0
1.6
29.8
0.4
2.1
36.6
1.8
1.2
32.8
0.4
2.2
39.8
1.9
1.2
36.7
0.4
2.4
44.1
2.1
1.4
42.0
0.4
2.6
49.8
2.3
1.4
45.5
0.4
2.7
53.5
2.4
1.6
49.3
0.4
2.9
57.7
2.6
1.6
53.4
0.4
3.0
62.0
2.8
1.6
59.0
0.4
3.3
68.2
3.0
830
790
730
790
640
640
550
530
510
530
460
510
420
510
380
440
340
440
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
2,070
1.2
0.734
3.110
0.529
3.110
0.391
1.840
0.270
1.160
0.195
1.160
0.154
0.734
0.126
0.734
0.100
0.529
0.0762
0.391
HV Power Cable
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
Max.
Dia.
2,630
3,270
4,300
No.
Conductor
Nominal
Min.
Area
Number of
wires
5,490
6,690
7,800
9,420
11,900
Instrumentation &
Communication Cable
No. of
Cores
0.6/1kV(1.8/3kV) FX-BFOU(VFD)
mm2
25
6
35
6
50
10
70
16
95
16
120
25
150
25
185
35
240
50
Max.
overall
dia.
mm
mm
0.41
0.31
0.41
0.31
0.41
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41
0.51
0.41
7.8
3.9
9.2
3.9
11.0
5.1
13.1
6.3
15.1
6.3
17.0
7.8
19.0
7.8
21.0
9.2
24.0
11.0
2.2
1.0
2.2
1.0
2.2
1.0
2.2
1.0
2.4
1.0
2.4
1.2
2.4
1.2
2.4
1.2
2.4
1.4
mm
mm
Dia. of
wire for
armour
mm
Thickness
Overall diameter
of
Nominal
Tolersheath
ance
mm
mm
Conductor Insulation
Resistance Resistance
(at 20)
(at 20)
(Max.)
(Min.)
Test
Voltage
Cable
Weight
mm
/km
-km
V/5min.
kg/km
1.2
29.3
0.3
2.1
35.7
1.7
32.4
0.4
2.2
39.4
1.9
1.2
35.8
0.4
2.3
43.0
2.0
1.4
41.6
0.4
2.6
49.4
2.3
1.4
45.0
0.4
2.7
53.0
2.4
1.6
50.2
0.4
2.9
58.6
2.6
1.6
53.2
0.4
3.0
61.8
2.8
1.6
57.3
0.4
3.2
66.3
3.0
1.8
65.6
0.4
3.5
75.2
3.3
750
790
650
790
570
630
490
470
470
470
420
450
380
450
350
390
310
380
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
6,500
3,500
2,240
1.2
0.795
3.390
0.565
3.390
0.393
1.950
0.277
1.240
0.210
1.240
0.164
0.795
0.132
0.795
0.108
0.565
0.0817
0.393
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
3C
+3E
Max.
dia. of
wires
2,840
3,640
4,870
5,770
7,210
8,300
VFD Cable
No.
Conductor
Nominal
Area
9,840
12,830
Technical Information
No. of
Cores
Offshore Cable
71
Technical Information
Electrical Data
73 ~ 81
82
83
Installation Recommendations
85 ~ 89
Core Identification
90
91
Certificates Approved
92
93
Technical Information
Technical Information
ELECTRICAL DATA
Conductor temperature
HV Power Cable
Two core
(A)
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
18
23
30
40
52
72
96
127
157
196
242
293
339
389
444
522
601
15
20
26
34
44
61
82
108
133
167
206
249
288
331
377
444
511
13
16
21
28
36
50
67
89
110
137
169
205
237
273
311
366
420
Instrumentation &
Communication Cable
NOTES)
No. of cores
1.0SQMM
1.5SQMM
2.5SQMM
5
7
9
12
14
16
19
24
30
37
44
11
9
9
8
7
7
7
6
6
5
5
13
12
11
10
10
9
9
8
7
7
7
18
16
14
13
12
12
11
10
10
9
8
VFD Cable
I1
3
Maximum conductor
temperature
35
40
45
50
55
60
65
70
75
80
90
1.10
1.05
1.00
0.94
0.88
0.82
0.74
0.67
0.58
0.47
Technical Information
I=
Offshore Cable
73
Technical Information
ELECTRICAL DATA
2. Capacitance, Inductance, Reactance, Impedance Data
3.6/6kV RFOU, 3.6/6kV RFCU, 3.6/6kV RFBU
Single core cable
Nominal Capacitance
Area
C
mm2
/km
10
16
25
35
50
70
95
120
150
185
240
300
0.247
0.284
0.328
0.362
0.408
0.466
0.528
0.581
0.624
0.695
0.742
0.770
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
/km
/km
/km
0.144
0.136
0.128
0.123
0.118
0.112
0.108
0.104
0.102
0.099
0.097
0.096
0.173
0.164
0.154
0.148
0.142
0.135
0.129
0.125
0.123
0.119
0.117
0.115
2.351
1.485
0.945
0.686
0.512
0.362
0.273
0.224
0.193
0.165
0.140
0.126
2.353
1.488
0.949
0.691
0.518
0.370
0.282
0.234
0.205
0.177
0.154
0.141
0.247
0.284
0.328
0.362
0.408
0.466
0.528
0.581
0.624
0.695
0.742
-
0.458
0.434
0.409
0.393
0.375
0.358
0.343
0.332
0.326
0.317
0.310
0.305
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
/km
/km
0.102
0.096
0.091
0.088
0.085
0.082
0.079
0.077
0.076
0.074
0.073
-
0.122
0.115
0.109
0.106
0.102
0.098
0.095
0.093
0.091
0.089
0.088
-
2.348
1.482
0.940
0.680
0.506
0.354
0.263
0.213
0.181
0.151
0.125
-
2.349
1.484
0.942
0.683
0.509
0.358
0.268
0.219
0.187
0.159
0.134
-
0.324
0.306
0.290
0.281
0.270
0.260
0.252
0.246
0.242
0.237
0.234
-
Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90
/km
16
25
35
50
70
95
120
150
185
240
300
0.228
0.261
0.287
0.321
0.365
0.411
0.450
0.484
0.535
0.591
0.651
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
/km
/km
/km
0.141
0.134
0.128
0.123
0.116
0.111
0.109
0.106
0.104
0.101
0.098
0.170
0.160
0.153
0.147
0.140
0.134
0.130
0.127
0.124
0.121
0.117
1.486
0.945
0.687
0.513
0.363
0.275
0.226
0.195
0.167
0.143
0.128
1.489
0.950
0.692
0.520
0.371
0.284
0.237
0.207
0.181
0.158
0.143
0.228
0.261
0.287
0.321
0.365
0.411
0.450
0.484
0.535
0.591
-
0.450
0.425
0.407
0.390
0.370
0.355
0.346
0.337
0.330
0.321
0.311
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
/km
/km
0.105
0.099
0.096
0.092
0.088
0.085
0.083
0.081
0.079
0.077
-
0.126
0.119
0.115
0.110
0.106
0.102
0.099
0.097
0.095
0.092
-
1.483
0.941
0.681
0.507
0.355
0.265
0.215
0.183
0.153
0.127
-
1.484
0.943
0.684
0.511
0.360
0.271
0.222
0.190
0.162
0.137
-
0.335
0.316
0.305
0.292
0.280
0.270
0.263
0.258
0.251
0.245
-
Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90
/km
25
35
50
70
95
120
150
185
240
300
0.215
0.235
0.261
0.295
0.330
0.360
0.386
0.424
0.468
0.514
74
Offshore Cable
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
/km
/km
/km
0.139
0.133
0.128
0.121
0.117
0.114
0.111
0.107
0.104
0.102
0.167
0.160
0.153
0.145
0.140
0.137
0.133
0.129
0.125
0.122
0.946
0.688
0.515
0.365
0.277
0.229
0.198
0.169
0.145
0.131
0.951
0.693
0.522
0.374
0.288
0.241
0.211
0.184
0.161
0.147
0.215
0.235
0.261
0.295
0.330
0.360
0.386
0.424
0.468
-
0.443
0.424
0.406
0.386
0.371
0.362
0.353
0.341
0.332
0.324
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
/km
/km
0.108
0.104
0.099
0.095
0.091
0.088
0.086
0.084
0.082
-
0.130
0.125
0.119
0.114
0.109
0.106
0.104
0.101
0.098
-
0.942
0.682
0.508
0.357
0.267
0.217
0.185
0.156
0.130
-
0.945
0.686
0.513
0.363
0.274
0.225
0.194
0.166
0.141
-
0.344
0.330
0.316
0.302
0.290
0.281
0.275
0.267
0.260
-
Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90
Technical Information
0.6/1kV(1.8/3kV) RFOU(VFD)
Capacitance
C
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
Impedance
Z
at 50 Hz 90
Impedance
Z
at 60 Hz 90
No.
mm2
/km
mH / km
/km
/km
/km
/km
3C
3E
3C
3E
3C
3E
3C
3E
3C
3E
95
16
120
25
150
25
185
35
240
50
0.582
0.255
0.080
0.096
0.264
0.269
0.667
0.249
0.078
0.094
0.213
0.219
0.715
0.244
0.077
0.092
0.181
0.188
0.736
0.238
0.075
0.090
0.151
0.159
0.794
0.233
0.073
0.088
0.125
0.134
Nominal
Area
HV Power Cable
0.6/1kV(1.8/3kV) BFOU(VFD)
Capacitance
C
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
Impedance
Z
at 50 Hz 90
Impedance
Z
at 60 Hz 90
No.
mm2
/km
mH / km
/km
/km
/km
/km
3C
3E
3C
3E
3C
3E
3C
3E
3C
3E
95
16
120
25
150
25
185
35
240
50
0.550
0.262
0.082
0.099
0.264
0.270
0.603
0.255
0.080
0.096
0.214
0.220
0.658
0.250
0.079
0.094
0.182
0.189
0.715
0.244
0.077
0.092
0.152
0.160
0.770
0.238
0.075
0.090
0.126
0.135
Nominal
Area
Instrumentation &
Communication Cable
/km
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
0.199
0.237
0.282
0.326
0.401
0.490
0.509
0.588
0.591
0.705
0.713
0.813
0.793
0.799
0.832
0.857
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
0.171
0.159
0.148
0.138
0.128
0.119
0.113
0.107
0.104
0.099
0.096
0.093
0.092
0.091
0.089
0.090
0.206
0.191
0.177
0.166
0.154
0.143
0.136
0.129
0.125
0.119
0.116
0.111
0.110
0.109
0.106
0.108
0.546
0.506
0.471
0.441
0.409
0.379
0.360
0.342
0.332
0.315
0.307
0.296
0.293
0.289
0.282
0.286
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90
/km
/km
/km
mH / km
/km
/km
/km
/km
15.557
9.641
5.995
3.968
2.350
1.484
0.943
0.683
0.509
0.358
0.269
0.219
0.188
0.160
0.134
0.122
15.558
9.642
5.996
3.969
2.351
1.486
0.946
0.687
0.514
0.364
0.276
0.228
0.197
0.171
0.147
0.136
0.305
0.345
0.379
0.435
0.477
0.500
0.589
0.685
0.705
0.715
0.770
0.834
0.834
0.834
0.848
0.848
0.356
0.329
0.307
0.291
0.272
0.257
0.254
0.245
0.245
0.236
0.235
0.230
0.231
0.232
0.230
0.230
0.112
0.103
0.096
0.091
0.085
0.081
0.080
0.077
0.077
0.074
0.074
0.072
0.072
0.073
0.072
0.072
0.134
0.124
0.116
0.110
0.102
0.097
0.096
0.092
0.092
0.089
0.089
0.087
0.087
0.088
0.087
0.087
15.557
9.640
5.994
3.967
2.348
1.481
0.939
0.679
0.504
0.352
0.262
0.211
0.179
0.150
0.124
0.109
15.557
9641
5.994
3.967
2.348
1.482
0.941
0.681
0.507
0.356
0.266
0.216
0.185
0.158
0.133
0.119
VFD Cable
mm2
Inductance
L
Technical Information
Offshore Cable
75
Technical Information
0.6/1kV BFOU, 0.6/1kV BFCU, 0.6/1kV BFBU
Single core cable * )
Nominal Capacitance
Area
C
mm2
/km
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
0.172
0.203
0.239
0.276
0.336
0.436
0.461
0.531
0.542
0.644
0.660
0.749
0.738
0.749
0.784
0.811
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
0.175
0.162
0.151
0.142
0.131
0.121
0.115
0.109
0.106
0.101
0.098
0.094
0.093
0.092
0.089
0.090
0.210
0.195
0.181
0.171
0.157
0.146
0.138
0.131
0.127
0.121
0.117
0.113
0.112
0.110
0.107
0.108
0.556
0.516
0.480
0.453
0.417
0.387
0.367
0.348
0.337
0.320
0.311
0.301
0.296
0.291
0.284
0.288
/km
15.557
9.641
5.995
3.968
2.350
1.484
0.943
0.683
0.510
0.359
0.269
0.220
0.188
0.160
0.135
0.122
15.558
9.642
5.996
3.969
2.351
1.486
0.946
0.687
0.515
0.365
0.277
0.228
0.198
0.171
0.147
0.136
/km
0.278
0.309
0.345
0.385
0.435
0.500
0.527
0.556
0.589
0.695
0.715
0.758
0.758
0.782
0.807
0.820
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
0.382
0.353
0.328
0.309
0.288
0.271
0.265
0.255
0.253
0.243
0.242
0.237
0.236
0.235
0.233
0.232
0.120
0.111
0.103
0.097
0.090
0.085
0.083
0.080
0.080
0.076
0.076
0.074
0.074
0.074
0.073
0.073
0.144
0.133
0.124
0.117
0.108
0.102
0.100
0.096
0.096
0.092
0.091
0.089
0.089
0.089
0.088
0.087
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
0.112
0.103
0.096
0.091
0.085
0.081
0.080
0.077
0.077
0.074
0.074
0.072
0.072
0.073
0.072
0.072
0.134
0.124
0.116
0.110
0.102
0.097
0.096
0.092
0.092
0.089
0.089
0.087
0.087
0.088
0.087
0.087
Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90
/km
/km
15.557
9.640
5.994
3.967
2.348
1.482
0.940
0.679
0.505
0.353
0.262
0.212
0.180
0.151
0.125
0.110
15.557
9641
5.994
3.967
2.349
1.483
0.941
0.681
0.508
0.356
0.267
0.217
0.186
0.158
0.134
0.120
0.6/1kV RU
Single core cable * )
Nominal Capacitance
Area
C
mm2
/km
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
0.199
0.237
0.282
0.326
0.401
0.490
0.509
0.588
0.591
0.705
0.713
0.813
0.793
0.799
0.832
0.857
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
0.142
0.131
0.121
0.114
0.105
0.099
0.095
0.092
0.091
0.086
0.085
0.083
0.083
0.083
0.081
0.081
0.170
0.157
0.146
0.137
0.126
0.119
0.114
0.110
0.109
0.103
0.102
0.100
0.099
0.099
0.098
0.097
0.451
0.417
0.387
0.363
0.334
0.316
0.303
0.292
0.288
0.274
0.271
0.264
0.264
0.263
0.259
0.258
76
Offshore Cable
/km
15.557
9.641
5.994
3.967
2.349
1.482
0.941
0.681
0.507
0.355
0.265
0.215
0.183
0.155
0.130
0.115
15.557
9.641
5.995
3.968
2.350
1.484
0.943
0.683
0.510
0.359
0.271
0.222
0.192
0.165
0.141
0.127
/km
0.305
0.345
0.379
0.435
0.477
0.500
0.589
0.685
0.705
0.715
0.770
0.834
0.834
0.834
0.848
0.848
0.356
0.329
0.307
0.291
0.272
0.257
0.254
0.245
0.245
0.236
0.235
0.230
0.231
0.232
0.230
0.230
Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90
/km
/km
15.557
9.640
5.994
3.967
2.348
1.481
0.939
0.679
0.504
0.352
0.262
0.211
0.179
0.150
0.124
0.109
15.557
9.641
5.994
3.967
2.348
1.482
0.941
0.681
0.507
0.356
0.266
0.216
0.185
0.158
0.133
0.119
Technical Information
0.6/1kV BU
/km
Reactance
X
50 Hz
Reactance
X
60 Hz
mH / km
/km
/km
1.5
0.172
0.468
0.147
0.176
15.557
2.5
0.203
0.432
0.136
0.163
9.641
4
0.239
0.401
0.126
0.151
5.994
6
0.276
0.376
0.118
0.142
3.967
10
0.336
0.351
0.110
0.132
2.349
16
0.436
0.326
0.102
0.123
1.483
25
0.461
0.315
0.099
0.119
0.941
35
0.531
0.300
0.094
0.113
0.681
50
0.542
0.295
0.093
0.111
0.507
70
0.644
0.283
0.089
0.107
0.356
95
0.660
0.276
0.087
0.104
0.266
120
0.749
0.270
0.085
0.102
0.216
150
0.738
0.268
0.084
0.101
0.184
185
0.749
0.266
0.083
0.100
0.156
240
0.784
0.261
0.082
0.098
0.130
CABLE
TYPE
:
0.6/1kV(1.8/3kV)
BFOU(VFD)
300
0.811
0.260
0.082
0.098
0.116
Inductance
L
Reactance
X
50 Hz
Reactance
X
60 Hz
Impedance Impedance
Z
Z
at 50 Hz 90 at 60 Hz 90
/km
/km
mH / km
/km
/km
/km
/km
15.557
9.641
5.995
3.968
2.350
1.484
0.943
0.684
0.511
0.360
0.272
0.223
0.192
0.165
0.141
0.128
0.278
0.309
0.345
0.385
0.435
0.500
0.527
0.556
0.589
0.695
0.715
0.758
0.758
0.782
0.807
0.820
0.382
0.353
0.328
0.309
0.288
0.271
0.265
0.255
0.253
0.243
0.242
0.237
0.236
0.235
0.233
0.232
0.120
0.111
0.103
0.097
0.090
0.085
0.083
0.080
0.080
0.076
0.076
0.074
0.074
0.074
0.073
0.073
0.144
0.133
0.124
0.117
0.108
0.102
0.100
0.096
0.096
0.092
0.091
0.089
0.089
0.089
0.088
0.087
15.557
9.640
5.994
3.967
2.348
1.482
0.940
0.679
0.505
0.353
0.262
0.212
0.180
0.151
0.125
0.110
15.557
9.641
5.994
3.967
2.349
1.483
0.941
0.681
0.508
0.356
0.267
0.217
0.186
0.158
0.134
0.120
HV Power Cable
mm2
Inductance
L
Instrumentation &
Communication Cable
Size
1.0mm2
1.5mm2
2.5mm2
Individual screen
nF/km
100
100
120
120
Collective screen
nF/km
80
80
90
90
mH/km
0.75
0.73
0.68
0.68
Inductance
VFD Cable
0.75mm2
Technical Information
Mutual
capacitance
unit
Offshore Cable
77
Technical Information
ELECTRICAL DATA
3. Short circuit current rating
The short circuit currents quoted here are for cables operating normally at maximum conductor temperature of 90.
HF EPR insulation is actually capable of withstanding short-term Temperature up to 250
According to ICEA P-32-382 Curves based on formula
Is = A x
(T2 + 234)
(T1 + 234)
0.115 log
t
T1 = 90, T2 = 250
Short circuit currents (kA)
Nominal
Area
mm2
78
0.05
0.07
0.1
0.14
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.5
1.3
1.0
0.8
0.7
0.6
0.5
0.4
0.3
0.3
0.3
0.3
0.2
0.2
0.2
2.5
2.0
1.6
1.3
1.1
0.9
0.8
0.6
0.6
0.5
0.5
0.4
0.4
0.4
0.3
3.2
2.5
2.1
1.8
1.5
1.3
1.0
0.9
0.8
0.7
0.7
0.6
0.6
0.6
4.9
3.8
3.2
2.7
2.3
1.9
1.5
1.3
1.2
1.1
1.0
0.9
0.9
0.8
10
8.2
6.3
5.4
4.5
3.8
3.2
2.6
2.2
2.0
1.8
1.7
1.6
1.5
1.4
16
13.0
10.1
8.5
7.1
6.0
5.0
4.1
3.6
3.2
2.9
2.7
2.5
2.4
2.2
25
20.6
15.9
13.5
11.3
9.5
8.0
6.5
5.6
5.0
4.6
4.3
4.0
3.8
3.6
35
28.5
22.1
18.7
15.6
13.2
11.1
9.0
7.8
7.0
6.4
5.9
5.5
5.2
4.9
50
38.6
29.9
25.3
21.2
17.9
15.0
12.2
10.6
9.5
8.6
8.0
7.5
7.1
6.7
70
55.9
43.3
36.6
30.6
25.9
21.6
17.7
15.3
13.7
12.5
11.6
10.8
10.2
9.7
95
77.5
60.0
50.7
42.4
35.9
30.0
24.5
21.2
19.0
17.3
16.0
15.0
14.1
13.4
120
97.9
75.8
64.1
53.6
45.3
37.9
31.0
26.8
24.0
21.9
20.3
19.0
17.9
17.0
150
120.3
93.1
78.7
65.9
55.7
46.6
38.0
32.9
29.5
26.9
24.9
23.3
22.0
20.8
185
150.8
116.8
98.8
82.6
69.8
58.4
47.7
41.3
36.9
33.7
31.2
29.2
27.5
26.1
240
198.3
153.6
129.8
108.6
91.8
76.8
62.7
54.3
48.6
44.3
41.0
38.4
36.2
34.3
300
248.7
192.6
162.8
136.2
115.1
96.3
78.6
68.1
60.9
55.6
51.5
48.2
45.4
43.1
400
329.3
255.1
215.6
180.4
152.5
127.6
104.1
90.2
80.7
73.6
68.2
63.8
60.1
57.0
500
401.0
310.6
262.5
219.6
185.6
155.3
126.8
109.8
98.2
89.7
83.0
77.7
73.2
69.5
Offshore Cable
Technical Information
4. Voltage drop
Rdc x 2L x I
V
2) A.C. circuit
Voltage drop rate of single-phase A.C.=
Voltage drop rate of three-phase A.C.=
x 100(%)
Rac x 2L x I
V
Rac x 2L x I
V
x x 100(%)
3
x 2
x x 100(%)
Where L
I
V
Rdc
Rac
Nominal
Area
R-dc
(at 20)
R-dc
(at 90)
R-ac
(at 90)
mm2
/km
/km
/km
100%
95%
90%
85%
80%
75%
70%
10
16
25
35
50
70
95
120
150
185
240
1.840
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
2.346
1.479
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
2.346
1.479
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.97
0.98
1.00
1.02
1.04
1.07
1.11
1.15
1.18
1.23
1.31
0.93
0.95
0.97
1.00
1.02
1.07
1.12
1.17
1.23
1.30
1.40
0.89
0.91
0.94
0.97
1.00
1.06
1.12
1.18
1.25
1.33
1.46
0.84
0.87
0.90
0.93
0.97
1.04
1.11
1.18
1.25
1.35
1.49
0.80
0.82
0.86
0.90
0.94
1.01
1.09
1.17
1.25
1.35
1.51
0.75
0.78
0.82
0.86
0.90
0.98
1.07
1.15
1.24
1.35
1.53
Instrumentation &
Communication Cable
R-dc
(at 90)
R-ac
(at 90)
mm2
/km
/km
/km
16
25
35
50
70
95
120
150
185
240
1.160
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
1.479
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
1.479
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
95%
0.99
1.00
1.02
1.04
1.08
1.12
1.16
1.19
1.25
1.32
90%
0.95
0.97
1.00
1.03
1.08
1.13
1.19
1.24
1.31
1.42
85%
0.91
0.94
0.97
1.01
1.06
1.13
1.20
1.26
1.35
1.48
80%
0.87
0.90
0.94
0.98
1.04
1.12
1.19
1.27
1.37
1.52
75%
0.83
0.86
0.90
0.95
1.02
1.10
1.19
1.26
1.38
1.54
70%
0.78
0.82
0.86
0.91
0.99
1.08
1.17
1.25
1.38
1.55
VFD Cable
R-dc
(at 20)
1) D.C. circuit
HV Power Cable
Calculate fomula
Nominal
Area
R-dc
(at 20)
R-dc
(at 90)
R-ac
(at 90)
mm2
/km
/km
/km
100%
95%
90%
85%
80%
75%
70%
25
35
50
70
95
120
150
185
240
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.01
1.02
1.05
1.08
1.12
1.17
1.20
1.26
1.34
0.98
1.00
1.03
1.08
1.14
1.20
1.25
1.33
1.44
0.94
0.97
1.01
1.07
1.14
1.21
1.28
1.37
1.50
0.91
0.94
0.98
1.05
1.13
1.21
1.29
1.39
1.54
0.87
0.91
0.95
1.03
1.12
1.21
1.29
1.40
1.57
0.83
0.87
0.92
1.00
1.10
1.19
1.28
1.40
1.58
Offshore Cable
Technical Information
79
Technical Information
ELECTRICAL DATA
0.6/1Kv(1.8/3kV) RFOU(VFD)
Nominal
Area
R-dc
(at 20)
R-dc
(at 90)
R-ac
(at 90)
mm2
95
16
120
25
150
25
185
35
240
50
ohm/km
0.195
1.160
0.154
0.734
0.126
0.734
0.100
0.529
0.076
0.391
ohm/km
0.249
1.479
0.196
0.936
0.161
0.936
0.128
0.675
0.097
0.499
ohm/km
0.251
1.479
0.198
0.936
0.164
0.936
0.131
0.675
0.101
0.499
95%
1.07
90%
1.07
85%
1.05
80%
1.03
75%
1.00
70%
0.97
1.00
1.10
1.11
1.10
1.08
1.06
1.04
1.00
1.13
1.15
1.15
1.14
1.12
1.10
1.00
1.16
1.20
1.21
1.21
1.20
1.19
1.00
1.22
1.28
1.31
1.32
1.33
1.32
Nominal
Area
R-dc
(at 20)
R-dc
(at 90)
R-ac
(at 90)
mm2
ohm/km
ohm/km
ohm/km
100%
95%
90%
85%
80%
75%
70%
95
16
120
25
150
25
185
35
240
50
0.195
1.160
0.154
0.734
0.126
0.734
0.100
0.529
0.076
0.391
0.249
1.479
0.196
0.936
0.161
0.936
0.128
0.675
0.097
0.499
0.251
1.479
0.198
0.936
0.164
0.936
0.131
0.675
0.101
0.499
1.00
1.07
1.07
1.06
1.04
1.01
0.98
1.00
1.10
1.11
1.11
1.09
1.07
1.05
1.00
1.13
1.15
1.15
1.15
1.13
1.11
1.00
1.17
1.21
1.22
1.22
1.21
1.20
1.00
1.23
1.29
1.32
1.33
1.34
1.33
Nominal
Area
R-dc
(at 20)
R-dc
(at 90)
R-ac
(at 90)
mm2
ohm/km
ohm/km
ohm/km
100%
95%
90%
85%
80%
75%
70%
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
12.2
7.56
4.70
3.11
1.84
1.16
0734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
0.0820
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.95
0.96
0.96
0.96
0.97
0.98
1.00
1.01
1.03
1.06
1.09
1.13
1.16
1.21
1.28
1.36
0.91
0.91
0.91
0.92
0.93
0.94
0.96
0.98
1.01
1.05
1.10
1.15
1.19
1.26
1.36
1.47
0.86
0.86
0.87
0.87
0.88
0.90
0.93
0.95
0.98
1.03
1.09
1.15
1.20
1.29
1.41
1.54
0.81
0.81
0.82
0.83
0.84
0.86
0.89
0.91
0.95
1.01
1.08
1.14
1.20
1.30
1.43
1.59
0.76
0.76
0.77
0.78
0.79
0.81
0.85
0.88
0.92
0.98
1.05
1.12
1.20
1.30
1.45
1.62
0.71
0.71
0.72
0.73
0.75
0.77
0.80
0.84
0.88
0.95
1.03
1.10
1.18
1.29
1.45
1.64
80
Offshore Cable
Technical Information
Nominal
Area
R-dc
(at 20)
R-dc
(at 90)
R-ac
(at 90)
mm2
ohm/km
ohm/km
ohm/km
100%
95%
90%
85%
80%
75%
70%
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
0.0820
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.95
0.96
0.96
0.96
0.97
0.98
1.00
1.01
1.03
1.06
1.10
1.13
1.16
1.21
1.28
1.36
0.91
0.91
0.91
0.92
0.93
0.94
0.96
0.98
1.01
1.05
1.10
1.15
1.20
1.26
1.36
1.48
0.86
0.86
0.87
0.87
0.89
0.90
0.93
0.95
0.98
1.03
1.10
1.15
1.21
1.29
1.41
1.55
0.81
0.81
0.82
0.83
0.84
0.86
0.89
0.92
0.95
1.01
1.08
1.14
1.21
1.30
1.44
1.59
0.76
0.76
0.77
0.78
0.79
0.82
0.85
0.88
0.92
0.98
1.06
1.13
1.20
1.30
1.45
1.62
0.71
0.71
0.72
0.73
0.75
0.77
0.81
0.84
0.88
0.95
1.03
1.11
1.19
1.30
1.46
1.64
HV Power Cable
0.6/1kV RU
R-dc
(at 20)
R-dc
(at 90)
R-ac
(at 90)
mm2
ohm/km
ohm/km
ohm/km
100%
95%
90%
85%
80%
75%
70%
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
12.2
7.56
4.70
3.11
1.84
1.16
0734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.249
0.196
0.161
0.128
0.0972
0.0774
15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
0.0820
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.95
0.96
0.96
0.96
0.97
0.98
0.99
1.00
1.02
1.04
1.08
1.11
1.14
1.19
1.25
1.32
0.90
0.91
0.91
0.92
0.92
0.94
0.95
0.97
1.00
1.03
1.08
1.12
1.16
1.23
1.32
1.42
0.86
0.86
0.86
0.87
0.88
0.89
0.91
0.94
0.96
1.01
1.06
1.11
1.17
1.25
1.36
1.48
0.81
0.81
0.81
0.82
0.83
0.85
0.87
0.90
0.93
0.98
1.04
1.10
1.16
1.25
1.38
1.51
0.76
0.76
0.77
0.77
0.79
0.80
0.83
0.86
0.89
0.95
1.02
1.08
1.15
1.25
1.39
1.54
0.71
0.71
0.72
0.72
0.74
0.76
0.79
0.82
0.86
0.91
0.99
1.06
1.13
1.24
1.39
1.55
Instrumentation &
Communication Cable
Nominal
Area
0.6/1kV BU
Inductive voltage drop coefficient
Nominal
Area
R-dc
(at 20)
R-dc
(at 90)
R-ac
(at 90)
mm2
ohm/km
ohm/km
ohm/km
100%
95%
90%
85%
80%
75%
70%
1.5
2.5
4
6
10
16
25
35
50
70
95
120
50
185
240
300
12.2
7.56
4.70
3.11
1.84
1.16
0.734
0.529
0.391
0.270
0.195
0.154
0.126
0.100
0.0762
0.0607
15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0344
0.249
0.196
0.161
0.128
0.0972
0.0774
15.6
9.64
5.99
3.97
2.35
1.48
0.936
0.675
0.499
0.344
0.251
0.198
0.164
0.131
0.1010
0.0820
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.95
0.96
0.96
0.96
0.97
0.98
0.99
1.00
1.02
1.05
1.08
1.11
1.14
1.19
1.25
1.32
0.90
0.91
0.91
0.92
0.92
0.94
0.96
0.97
1.00
1.03
1.08
1.12
1.17
1.23
1.32
1.42
0.86
0.86
0.86
0.87
0.88
0.89
0.92
0.94
0.97
1.01
1.07
1.12
1.18
1.25
1.36
1.48
0.81
0.81
0.82
0.82
0.83
0.85
0.88
0.90
0.93
0.99
1.05
1.11
1.17
1.26
1.38
1.52
0.76
0.76
0.77
0.77
0.79
0.80
0.83
0.86
0.90
0.95
1.02
1.09
1.16
1.25
1.39
1.54
0.71
0.71
0.72
0.73
0.74
0.76
0.79
0.82
0.86
0.92
1.00
1.07
1.14
1.24
1.40
1.55
Offshore Cable
Technical Information
VFD Cable
81
Technical Information
VOLTAGE RATING SELECTION
Selection cable for A.C systems
System voltage (kV)
Supply
system
3-Phase 4-Wire
3-Phase 4-Wire
3-Phase 3-Wire
3-Phase 3-Wire
2-Phase 3-Wire
or 2-Phase 4-Wire
Supply
category
A&B
C
A&B
A&B
2-Phase 3-Wire
or 2-Phase 4-Wire
1-Phase 3-Wire
A&B
1-Phase 3-Wire
1-Phase 2-Wire
or
1-Phase 1-Wire
Note)
Phase to earth
(Uo)
Recommended (kV)
Phase to phase
(U)
Above
Up to and
including
Above
Up to and
including
Maximum
sustained
voltage
(Um)
IEC
standard
BS
standards
UO / U
UO / U
0.15 / 0.25
0.15
0.25
0.28
0.15 / 0.25
0.15
0.6
0.25
1.2
0.6 / 1
0.6 / 1
0.15
0.15 / 0.25
0.15 / 0.25
0.15
0.6
0.6 / 1
0.6 / 1
0.15
0.25
0.28
0.15 / 0.25
0.15 / 0.25
0.15
0.6
0.25
1.2
0.6 / 1
0.6 / 1
0.6
1.9
3.3
3.6
1.8 / 3
1.9 / 3.3
1.9
3.8
3.3
6.6
7.2
3.6 / 6
3.8 / 6.6
3.8
6.35
6.6
11
12
6 / 10
6.35 / 11
6.35
8.7
11
15
17
8.7 / 15
8.7
12.7
15
22
24
12 / 20
12.7 / 22
0.15 / 0.25
0.15
0.15 / 0.25
0.15
0.6
0.6 / 1
0.6 / 1
0.6
1.9
1.8 / 3
1.9 / 3.3
1.9
3.3
3.6
3.6 / 6
3.8 / 6.6
3.3
6.6
7.2
6 / 10
6.35 / 11
6.6
11
12
8.7 / 15
11 / 11
11
15
17.5
12 / 20
12.7 / 22
0.15
0.21
0.15 / 0.25
0.15 / 0.25
0.15
0.6
0.84
0.6 / 1
0.6 / 1
0.15
0.15 / 0.25
0.15 / 0.25
0.15
0.a6
0.6 / 1
0.6 / 1
0.6
1.9
1.8 / 3
1.9 / 3.3
0.15
0.25
0.28
0.15 / 0.25
0.15 / 0.25
0.15
0.6
0.25
1.2
0.6 / 1
0.6 / 1
0.15 / 0.25
0.15
0.15 /0.25
0.25
0.6
0.6 / 1
0.6 / 1
0.15
0.15 /0.25
0.15 / 0.25
0.15
0.6
0.6 / 1
0.6 / 1
0.6
1.9
1.8 / 3
19. / 3.3
1.9
3.3
3.6
3.6 / 6
3.8 / 6.6
3.3
6.6
7.2
6 / 10
6.35 / 11
6.6
11
12
8.7 / 15
11
15
17.5
12 / 20
12.7 / 22
The rated voltage of the cable for a given application shall be suitable for the operating condition in the system in which the cable is used. To facilitate the
choice of the cable, the system are divided into the following three categories
Category A : This category comprises those systems in which any phase conductor than comes in contact with earth or an earth conductor , is
automatically disconnected from the system within 1 minute.
Category B : This category comprises those systems in which, under fault conditions, are operated for a short time, not exceeding 8 hours on any
occasion, faults in any year should not exceed 125 hours.
Category C : This category comprises all systems which do not fall into categories A and B.
82
Offshore Cable
Technical Information
ASTM D 2863
Instrumentation &
Communication Cable
Technical Information
VFD Cable
HV Power Cable
Offshore Cable
83
Technical Information
7. Mud resistant test
ud resistant cables shall be designed with sheathing compounds suitable for installation and operation in contact with MUD
M
unless otherwise specified. Type SHF Mud.
The variation in the tensile strength and elongation at break values from those values obtained on the
unaged sample shell not exceed 25%.
The volume swell and weight increase shell not exceed 20%and 15% respectively.
2) Drilling fluid mud test requirements for sheathing compound SHF mud
Test shall be carried out on dumbbells as specified in IEC 60092-359 Table clause 3 except that the test fluids and
conditions shall be as given in Table 1.
Tesa fluid
Temperature
Duration
100
7d
70
56d
70
56d
8. Oil resistance
All thermoset sheathed cables shall be suitable for an oil production installation. The oil resistance properties shall be
demonstrated by a test according to IEC 60092-359 Table clause 3, type SHF2.
84
Offshore Cable
Technical Information
INSTALLATION RECOMMENDATIONS
HV Power Cable
The following installation recommendations are in accordance with IEC regulation and practice.
Different regulations may apply in other countries.
Type of cable
The bending radius for the installation of cables should be not less than the values given as follows;
Minimum bending radius
Unarmored or unbraided
1.8/3kV
3.6/6kV
above
D 25mm
4XD
D 25mm
6XD
6XD
Tape screened
8XD
Single core
12 X D
3-core
9XD
r
Instrumentation &
Communication Cable
Up to
Note) For cables rated at 3.6/6(7.2)kV and above employing flexible conductor
stranding(Class5) and braid insulation shields indicating a minimum bend radius of 6D
for unarmoured cables and 8D for armoured cables in concurrence with the approval
of the cable manufacturer.
2. Installation temperature
Minimum recommended installation temperature for cables shall be -20.
But, if the ambient temperature were below -20, the cable should be installed after maintained at room temperature
(about 15~25) for 24 hours or more.
VFD Cable
3. Pulling tension
The cable pulling tension during installation can be estimated by means of the following formula:
p=5kg x total cross section of conductors in the armoured cable or,
p=2.5kg x total cross section of conductors in the unarmoured cable
Technical Information
Additional tension will be supplied from the braid and the insulation and sheathing compound.
Offshore Cable
85
Technical Information
4. Explosion risk areas
1) Areas
The areas on board are usually classified in two main categories with regards to the explosion risk :
Hazardous areas : Areas in which explosive gas-air mixtures are, or may be expected to be,present in
quantities such as to require special precautions for the construction and use of electrical apparatus.
Safe areas(non-hazardous areas ) : Area in which explosive gas-air mixtures are not expected to be, present in
quantities such as to required special precautions for the construction and use of electrical apparatus.
A hazardous area is divided into three zones :
Zone 0 : in which an explosive gas-air mixture is continuously present or present for long periods.
Zone 1 : in which an explosive gas-air mixture is likely to occur in normal operation
Zone 2 : in which an explosive gas-air mixture is not likely to occur, and if occurs it will only exist for a short time
2) Installation of cables
For cables to be used in zone 0 and zone 1, one of the following types of protection is required:
A non-metallic outer sheath in combination with braiding or other metallic covering for earth fault
detection and mechanical protection. A non-metallic outer sheath is, however, not required if the
screen or armouring consists of a corrosion resistant bronze alloy.
A
lead sheathing in addition to further mechanical protection, for example armour braiding or
non-metallic impervious sheath.
For mineral insulated cables, a copper or stainless steel sheath.
Single core cables in installations with A.C or D.C. current with a high ripple content should be of types
without screen of armouring. where mechanical damage is possible, such cables should otherwise be
mechanically protected or installed in ducts or similar.
For installations in zone 2, cables without screen or armour can be used.
86
Offshore Cable
Technical Information
1) General requirements
All metal coverings of cables, armouring or shielding shall be earthed. Earthing must be provided at both ends except
for final sub-circuits where earthing at only one end(the supply end)is sufficient.
Earthing at one end is permitted where it is required for technical or safety reasons, control and instrumentation cables,
mineral insulated cables, intrinsically safe circuits, control circuits etc.
Metal covering of single core cable for AC and single core cable for DC with ripple content exceeding 10% and having
a current rating exceeding 20A is to be earthed at one and only.
when single core cables for AC and DC with ripple content higher than 10% are installed in or passing through
hazardous areas, the metal screen or armour is to be earthed inside the hazardous area to avoid dangerous potential
between screen armour and earthed part of the installation
Instrumentation &
Communication Cable
Earth connections for metal coverings shall be carried out with conductors having cross sectional areas related to the
cross sectional areas of the phase conductors and the current ratings of the cables, or at least the same cross sectional
areas as the metal covering it self.
Metal coverings of cables may be earthed through clamps. The clamps must grip the metal covering of the cable and must
be connected to the hull and provide a good conductive connection between the metal covering and the hull. The metal
clamps must be corrosion resistant.
VFD Cable
The metal coverings of cables may be earthed by means of glands intended for the purpose and so designed as to
ensure an effective earth connection. The glands shall be firmly attached to, and in effective electrical contact with, a
metal structure earthed in accordance with these regulations.
Offshore Cable
Technical Information
Metal pipes and cable conduits are to be earthed. Pipes and conduits may be earthed by being screwed into a metal
enclosure, or by nuts in both sides of the wall of metallic enclosure, provided that the surface is clean and free from rust,
scale or print.
Comments : For intrinsically safe circuits it is important to separate the earth conductor from the protective earthing.
The resistance between a zener barrier earth and protective earth must be max.
1ohm and preferably less than. 0.1ohm to avoid that possible fault current does not lead to a potential increase in the
system.
87
Technical Information
6. Fixing of cables
Cables are to be suitably fixed to the supports. In order to guard against the effects of
electrodynamics forces developing on the occurrence of a short circuit, single core cables should
be firmly fixed by using supports of a strength adequate to withstand forces corresponding to the values of prospective
short circuit current.
The requirement concerning fixing can normally be fulfilled when the cables are clamped as follows:
For cables entering enclosures and conduits the nearest clamp is to be placed at a minimum distance from the entry of 10
times the diameter the cable concerned from the entry.
At other points the distance between the clamps must not exceed the in the following table:
Above
Up to
200
250
13
250
300
12
20
300
350
20
30
350
400
30
400
450
88
Offshore Cable
Technical Information
Cables must at least meet the flame retardant requirements. On board passenger ships, cargo-ships
and mobile offshore units, where requirements are considered to be satisfied if the cables have
characteristics complying withe the cable bunch test IEC-Publication 60332-3, or fire stops are installed in accordance with
the following recommendations:When cable complying with single-cable test, but not the cable-bunch-test, are installed, fire
stops are to be provided in enclosed or semi-enclosed spaces except for cargo rooms and tunnels in cargo areas.
a) For vertical cable runs
- with a max. distance between fire stops of two decks or 6 meters, unless installed in totally enclosed cable ducts
- at the main and emergency switchboard
- where cables enter into an engine control room
- at centralized control panels for propulsion machinery and essential auxiliaries
- at the entrance to cables ducts
- Fire stops shall be as specified in item a) above but the maximum. distance between fire stops may be increased to 14m.
Instrumentation &
Communication Cable
When choosing cable types special attention should be paid to reduce possible damage due to corrosion in case of a fire.
Non-halogen free cables(materials)will give off corrosive gases during a fire.
The corrosion effect depends on the amount of halogens in the materials used.
Flame retardant cables are to give characteristics complying with the test requirements in IEC-Publication 60332-1, with
amendments.
Fire resistant cables are to give characteristics complying with the requirements in IEC-Publication 60331.
Cables and flexible cables for intrinsically safe circuits must have screen or similar of a conducting material and the outer
sheath must be of an insulating material. A non-metallic outer sheath is, however, not required if the screen or armour
consists of a corrosion resistant bronze alloy. Where there is no danger of interference from the external electrical or
magnetic fields, short flexible cables may be used without screen.
a) Associated equipment
Associated equipment(e.g.power supply units) shall be situated in a safe area or has protection as mentioned in "Explosion risk areas."
b) Connection of equipment
Within limitations laid down in 3., ordinary non-explosion protected equipment may be connected to intrinsically safe equipment, provided that it is designed
to meet regulations in other respects.
VFD Cable
With intrinsically safe circuits special considerations must be given to ensure that the circuits characteristics (including connected equipment, cables,
conductors etc.) satisfy any limitations in the test certificate.
Such limitations may be maximum values for capacitance and inductance etc. It is pointed out there is a danger of damage to i.s equipment when using
normal equipment for insulation testing
d) Adjacent location
Conductors for i.s safe circuits and conductors for non-i.s safe circuits shall not be run together in the same cable, flexible cable, conduit, cables bunch etc.
Technical Information
Where i.s circuits are exposed to magnetic or electrical field that may destroy the intrinsic safety of the system.
Precautions must be taken during installation. Such precautions may be:
- cables for i.s circuits and non-i.s circuits to be installed a minimum distance of 50mm apart.
The minimum distance to heavy current cables using D.C with a high ripple content should be 300mm.
- cables for i.s circuits and non-i.s circuits to be separated panel of conducting material which is earthed.
- cables for i.s circuits to have effective transposition.
f) Marking
The marking may be a marking plate or by colour marking of the cables when using colour marking, the colour should be light blue.
Offshore Cable
89
Technical Information
CORE IDENTIFICATION
1. High voltage power cables
The individual cores shall be identified by the colored semi-conducting tape or colored ribbon tape run
longitudinally on the non-metallic part of insulation screening and the colour scheme shall be as follows:
1 core : Off-white (Grey)
3 core : Off-white (Grey), Black, Red, or Off-white(Grey), Red, Blue
3C
Green / Yellow
Blue
Brown
4C
Green / Yellow
Brown
Black
5C
Green / Yellow
Blue
Brown
Black
2C
Blue
Brown
3C
Brown
Black
Grey
Grey
4C
Blue
Brown
Black
Grey
Grey
5C
Blue
Brown
Black
Grey
90
Offshore Cable
Black
Technical Information
HV Power Cable
Right
Wrong
Shaft
2. In case of a forklift
Drums should not be damaged by a forklift.
Instrumentation &
Communication Cable
Right
Wrong
Storage
Technical Information
Dont leave the protecting packing materials and outside package until remove it for setting up cables.
Should construct a fence to protect against damages by moving machines.
Keep it inside or in depository when safekeeping in long term.
(For reference, drums and packages can stand against dry whether outside the house)
Must seal both sides of cables remaining in the drums the cap and heat-contracting tube so that moisture
doesnt soak in after finishing the removal of exterior packing materials and cutting and installing cables.
Offshore Cable
91
Certificates Approved
92
Offshore Cable
BV
GOST-R
Instrumentation &
Communication Cable
DNV
ABS
VFD Cable
HV Power Cable
Technical Information
Technical Information
Offshore Cable
93
Memo
94
Offshore Cable
Technical Information
VFD Cable
Instrumentation &
Communication Cable
HV Power Cable
Technical Information
Offshore Cable
95
www.tmc-cable.com
Head Office / Ipjang Factory
#368-7, gasan-ri, Ipjang-Myeon, Cheonan-si, Chungnam, Korea
Tel. +82-41-589-6500 Fax. +82-41-589-6400
Bukmyeon Factory
#330-852, Maesong-ri, Buk-Myeon, Cheonan-si, Chungnam, Korea
Tel. +82-41-554-0630 Fax. +82-41-553-7166
Seoul Office
#100-704,13F Danam Building, Namdaemunno 5-ga, Jung-gu, Seoul, Korea
Tel. +82-2-771-3434 Fax. +82-2-771-3003
Geoje Office
KHAN Building 1F, 915 Aju-dong, Geoje-si, Gyeongsangnam-do, Korea
Tel. +82-55-688-5261 Fax. +82-55-688-5262
Dalian Office(China)
Changjiang Office Building No.123 Changjiang Road. Zhongshan District 939/940 Room Dalian,China.
Tel. +86-411-8252-9669, 9769 Fax. +86-411-8269-8316
TMC1309-1000