hecked by Date Floor / room area Element Sub element Types of defects Categories of defects Causes

: Ahmad Fadli Mohammad : 7.12.2012 : Office room Wall Wall finishes Peeling of paint Thermal agent

Time

: 10:00 a.m.

Legend of defect colour in building plan

Remedies

1. Poor quality of the paint used. 2. The vandalism or maybe was hit by the hard thing during the work. 3. The extreme change of the temperature of the building had make some of the paint being loses it function due the not suitable paint 1. Take off the paint at the affected area and paint it with the suitable paint. 2. Install the skirting. Image/photo Others information Peeling of paint The defect at this area can be considered as a minor defect that it dont give a large affect to the performance, appearance and the functional of the building and the action need to be taken in order to avoid this defect from being serious or spread.

Image and Others information

Condition Assessment Legend :

A A : Good B : Fair

B C : Poor

C D : Very Poor

Checked by Date Floor / room area Element Sub element Types of defects Categories of defects Causes

: Ahmad Fadli Mohammad : 7.12.2012 : Internal wall Wall Wall finishes Crockery Building user

Time

: 09.05a.m.

Legend of defect colour in building plan

1. Accidently hit by the hard thing by the human around it. 2. Vandalism can also be the causes. 1. Refer to the responsible contractor.

Remedies Image/photo Others information Crockery This type of defect sometime because of the human error that accidently makes this defect.

Image and Others information

Condition Assessment Legend :

A A : Good B : Fair

B C : Poor

C D : Very Poor

Checked by Date Floor / room area Element Sub element Types of defects Categories of defects Causes

: Ahmad Fadli Mohammad : 7.12.2012 : Apron Floor Floor finishes Crack Thermal agent 1. 2. 3. 1. 2. 3. 4.

Time

: 09.07a.m.

Legend of defect colour in building plan

Remedies

The changes of the temperature due to the heat and cooling of the sun light. The shrinkage of the cement render also can be causes of this crack. The wrong ration of mixture or poor workmanship. Hack off the parts that crack. Form a shape for the joint with the cement render. Damp that area about 24 hours before applying with the new layer of cement render. Replace that part with the new cement render. Image/photo Others information Crack The cracks on the floor are the defect that was obviously gives the effect to the appearance of the building. These cracks need to be repairing it immediately in order to prevent it from spread.

Image and Others information

Condition Assessment Legend :

A A : Good B : Fair

B C : Poor

C D : Very Poor

Checked by Date Floor / room area Element Sub element Types of defects Categories of defects Causes

: Ahmad Fadli Mohammad : 7.12.2012 : Emergency Exit WALL Wall finishes Bleeding of paint Thermal agent 1. 2. 3. 1.

Time

: 11.30a.m.

Legend of defect colour in building plan

Frequent brushing on the same spot Use of incompatible coats or thinner Leaching out of the existing paint film. Allow drying before painting over with an appropriate buffer coat (refer to manufacturers recommendation)

Remedies Image/photo Others information Bleeding of paint This defect type was not really affect the building because the defect occurs can be considered as the minor defect. This defect can be bad if we dont treat it earlier

Image and Others information

Condition Assessment Legend :

A A : Good B : Fair

B C : Poor

C D : Very Poor

Checked by Date Floor / room area Element Sub element Types of defects Categories of defects Causes Remedies

: Ahmad Fadli Mohammad : 7.12.2012 : Toilet Wall Internal wall Water seepage Chemical agent 1. Water seepage through roof,toilets

Time

: 09.50a.m.

Legend of defect colour in building plan

1. Arrest moisture source 2. Prepare and treat the surface 3. Repaint on receiving surface with moisture content not exceeding 6% (or refer to manufacturers recommendation) Image/photo Others information Preventive Measure Install proper waterproofing system before painting

Image and Others information

Condition Assessment Legend :

A A : Good B : Fair

B C : Poor

C D : Very Poor

Checked by Date Floor / room area Element Sub element Types of defects Categories of defects Causes

: Ahmad Fadli Mohammad : 7.12.2012 : 5th floor Floor tiles Finishes Stains or discoloration Thermal agent 1. 2. 1. 2. 3. 4.

Time

: 10.30a.m.

Legend of defect colour in building plan

Remedies

Water from spills, water from continual source Improper maintenance with water or harsh chemicals. Correct water source, let dry. Maximize sunlight. Relocate area rugs. Correct maintenance procedures and products Image/photo

Others information

Image and Others information

Condition Assessment Legend :

A A : Good B : Fair

B C : Poor

C D : Very Poor

Checked by Date Floor / room area Element Sub element Types of defects Categories of defects Causes

: Ahmad Fadli Mohammad : 7.12.2012 : Courtyard Floor Floor finishes Chipping of tiles Thermal agent 1. 2. 1. 2.

Time

: 09.55a.m.

Legend of defect colour in building plan

Dropping any hard, sharp, heavy object onto a tile can chip the surface Scrape out all the grout around the affected (chipped) tile Replace the tile and grout
Image/photo Others information

Remedies

Image and Others information

Condition Assessment Legend :

A A : Good B : Fair

B C : Poor

C D : Very Poor