Vous êtes sur la page 1sur 9

4 Outdoor Cabinets

4.1 Outdoor Cabinets General Information


There are four classes of outdoor cabinets available to house the 9100 BTS equipment: COME/CODE - three-door outdoor cabinet COMI/CODI/CPT2/MBO2/MBO2E/MBO2EDC - two-door outdoor cabinet COEP/MBOE/MBOEDC/MBOEEDC - one-door outdoor extension cabinet MBO1/MBO1DC/MBO1T/MBO1E/MBO1EDC - one-door outdoor cabinet CBO/CBIE/CBOE - one-door outdoor cabinet. The COEP is designed to allow the extension in the field of a COMI to a COME and a CODI to a CODE. The MBOE/MBOEE is designed to extend an MBO1/MBO1E to an MBO2/MBO2E. The MBOEDC/MBOEEDC is designed to extend an MBO1DC/MBO2EDC to an MBO2DC/MBO2EDC. All outdoor cabinets support both omnidirectional and sectorized configurations. The following figures show the possible positions of the main modules. The positions of the modules in the subracks are configuration dependent; for more information; refer to Configurations - Rack Layouts (Section 2) . COME/COMI/CODE/CODI/CPT2 cabinets have two or three compartments: Side compartment BTS compartment 1 BTS compartment 2. MBO1/MBO1E/MBO2/MBO2E cabinets have one or two compartments: MBO1/MBO1E MBOE/MBOEE. MBO1DC/MBO1EDC/MBO2DC/MBO2EDC cabinets have one or two compartments: MBO1DC/MBO1EDC MBOEDC/MBOEEDC. The MBO1T, CBO and CBIE/CBOE cabinets have one compartment.

530 / 1056

3BK 21642 AAAA TQZZA Ed.22

4 Outdoor Cabinets

4.1.1 COME/COMI/COEP with Modules


COME COMI
Service Light and AC Power Socket

COEP

Side Compartment

BTS Compartment 1

BTS Compartment 2

Smoke Detector Service Light and AC Power Socket (not neces sarily equipped)

Equipment Labels Door Alarms Override Key Switch Interconnection Panel SRACDC or ACSR Document Holder BTSRIOUT Battery (2 BU41s or BU100) Flood De tector (installation on left or right posi tion) STASR 1 STASR 3 Electricity Meter Option Option STASR 5

ACSB

DCDP

STASR 2

STASR 4

Not neces sarily equipped

Door Alarm Switch (installation on upper or lower posi tion)

Front View

HEAT2 HEAT2

HEAT2

HEAT2

HEAT2

HEX2

HEX2

HEX2

Top View

Figure 360: COME/COMI/COEP Module Positions

3BK 21642 AAAA TQZZA Ed.22

531 / 1056

4 Outdoor Cabinets

4.1.2 CODE/CODI/COEP with Modules


CODE CODI COEP

Service Light and AC Power Socket Equipment Labels Door Alarms Override Key Switch (Busbar) Interconnection Panel Document Holder

Side Compartment

BTS Compartment 1

BTS Compartment 2 Smoke Detector

ACSU STASR 3 STASR 7 STASR 6

Options or 2nd Battery

STASR 2

STASR 5

Battery

STASR 1

STASR 4 Door Alarm Switch

LPFU Flood Detector

BTSRIOUT

Front View

HEAT2 HEX2

HEAT2

HEAT2

HEX2

HEX2

Top View

Figure 361: CODE/CODI/COEP Module Positions

532 / 1056

3BK 21642 AAAA TQZZA Ed.22

4 Outdoor Cabinets

4.1.3 CPT2 with Modules


Service Light and AC Power Socket Equipment Labels Door Alarms Override Key Switch (Busbar) OUTC Document Holder STASR 5 STASR 2 Side Compartment BTS Compartment 1 Smoke Detector

ACSU STASR 6 STASR 3

Door Alarm Switch

Battery

STASR 4

LPFU Flood Detector

Front View

HEAT2 HEX2

HEAT2

HEX2

Top View

Figure 362: CPT2 Module Positions

3BK 21642 AAAA TQZZA Ed.22

533 / 1056

4 Outdoor Cabinets

4.1.4 MBO1 with Modules


Service Light Smoke Detektor AC Switch Unit (ACMU) LPFM ADAM4

STASR 7 HEX Breaker Options Area (e.g. Microwaves) Door Alarms Override Key Switch

STASR 3 Batteries

Document Holder Battery Cover STASR 2

OUTC

Batteries

STASR 1

Door Alarm Switch Flood Detector

Front View

HEAT2

HEX4

Top View

Figure 363: MBO1 Module Positions

534 / 1056

3BK 21642 AAAA TQZZA Ed.22

4 Outdoor Cabinets

4.1.6 MBO1E with Modules


Service Light

Document Holder

Smoke Detektor

Options Area (e.g. Microwaves)

HEX Breaker STASR 3 Door Alarms Override Key Switch

Batteries

STASR 2 OUTC

Battery Cover

ACDUE

STASR 1

PM 18

Door Alarm Switch Flood Detector

Front View

HEAT2

HEX9

Top View

Figure 365: MBO1E Module Positions

536 / 1056

3BK 21642 AAAA TQZZA Ed.22

4 Outdoor Cabinets

4.1.9 MBO2 with Modules


MBO2 Service Light Smoke Detektor AC Switch Unit (ACMU) LPFM ADAM4 MBO1 MBOE

STASR 7

STASR 0

HEX Breaker

Options Area (e.g. Microwaves)

Door Alarms Override Key Switch STASR 3 STASR 6

Batteries OUTC Document Holder Battery Cover STASR 2 STASR 5

Batteries

Door Alarm Switch STASR 1 STASR 4 Flood Detector

Front View

HEAT2

HEAT2 HEX4 HEX3

Top View

Figure 368: MBO2 Module Positions

3BK 21642 AAAA TQZZA Ed.22

539 / 1056

4 Outdoor Cabinets

4.1.10 MBO2E with Modules


MBO2E Service Light MBO1E MBOEE

Smoke Detektor Document Holder HEX Breaker

STASR 3 Options Area (e.g. Microwaves)

STASR 6

Door Alarms Override Key Switch

Batteries

STASR 2

STASR 5

ACDUE

OUTC

Battery Cover STASR 1 Batteries PM 18 STASR 4 Door Alarm Switch Flood Detector

Front View

HEAT2 HEAT2 HEX9

HEX8

Top View

Figure 369: MBO2E Module Positions

540 / 1056

3BK 21642 AAAA TQZZA Ed.22

4 Outdoor Cabinets

4.1.13 CBO with Modules


CBO Options Area (e.g. Microwaves) Door Switch

DCUC ACUC STASR 2 OUTC

ADAM 2

LPFC

External Batteries Breaker STASR 1 Cables Entry

Front View

HEAT3

HEX5

Top View

Figure 372: CBO Module Positions

3BK 21642 AAAA TQZZA Ed.22

543 / 1056

Vous aimerez peut-être aussi