Académique Documents
Professionnel Documents
Culture Documents
139
OVERVIEW
High performance steel anchors
M8 - M12
High performance anchor FH II-S, zinc plated steel High performance anchor FH II-SK, zinc plated steel High performance anchor FH II-H, zinc plated steel High performance anchor FH II-B, zinc plated steel High performance anchor FH-S A4*), stainless steel A4
Approved for: Cracked and non-cracked concrete C20/25 to C50/60. Also suitable for: Concrete C12/15 Natural stone with dense structure. For xing of: Steel constructions Railings Consoles Ladders Cable trays Machines Staircases Gates Facades Window elements *) not part of the approval
DESCRIPTION
Heavy-duty sleeve anchor for push-through installation. When the hexagon nut or bolt is tightened, the cone is pulled into the expansion sleeve and expands it against the hole wall. FH version made from A4 stainless steel for outdoor use and in damp conditions (not part of the approval).
FH II - ADVANTAGES AT A GLANCE
The unit of cone and expansion clip leads to the highest tensile strength and smallest edge distances and axial spacings in cracked and non-cracked concrete. Fixing with four dierent head designs - hexagon head screw - countersunk screw - cap nut - bolts
Advantages/benets
For stylish xings. Highest tensile and shear loads for push-trough installation. Simple and easy setting: Anchor setting with a few, light hammer blows. Surface ush removal. Minimum axial and edge distances. Anchor versions for xings with sophisticated design: FH-S (hexagon head screw), FH-H (cap nut) and FH-SK (countersunk screw). All anchors can be removed ush with the surface.
The black plastic ring provides highest performance and takes a torque slippage (so called internal expansion). Any turning of the anchor is prevented.
The high tensile strength of the steel (strength class 8.8) and the optimum interaction of screw and sleeve (enlargement of the shear area) allows the highest shear loads.
INSTALLATION
Type of installation
Push-through installation
STANDARDS
You will find everything that has standards on page 34 under the keywird approvals.
ETA
do [mm]
l [mm]
t x [mm]
FH 10/10 S FH 10/25 S FH 10/50 S FH II 12/10 S FH II 12/25 S FH II 12/50 S FH II 15/10 S FH II 15/25 S FH II 15/50 S FH II 18/10 S FH II 18/25 S FH II 18/50 S FH II 24/25 S FH II 24/50 S FH II 28/30 S FH II 28/60 S FH II 32/30 S FH II 32/60 S
45030 45031 45032 44884 44885 44886 44887 44888 44889 46847 44894 44896 44898 44900 44901 44902 44903 44904
7 4 1 7 4 1 8 5 2 0 6 0 4 4 1 8 5 2
10 10 10 12 12 12 15 15 15 18 18 18 24 24 28 28 32 32
85 100 125 90 105 130 100 115 140 115 130 155 150 175 185 215 210 210
84 99 124 90 105 130 106 121 146 118 132 157 160 185 192 222 215 245
10 25 50 10 25 50 10 25 50 10 25 50 25 50 30 60 30 60
M6 M6 M6 M8 M8 M8 M 10 M 10 M 10 M 12 M 12 M 12 M 16 M 16 M 20 M 20 M 24 M 24
10 10 10 13 13 13 17 17 17 19 19 19 24 24 30 30 36 36
50 50 50 50 50 25 25 25 25 20 20 20 10 10 4 4 4 4
ETA
do [mm]
l [mm]
SW pcs.
2 9 6 2 9 6 3 0 7
12 12 12 15 15 15 18 18 18
60 60 60 70 70 70 80 80 80
15 25 50 15 25 50 15 25 50
M8 M8 M8 M 10 M 10 M 10 M 12 M 12 M 12
5 5 5 6 6 6 8 8 8
25 25 25 25 25 25 20 20 20
D [mm] 22 22 32
counter bore 90 90 90
ETA
do [mm]
l [mm]
t x [mm]
FH 10/10 H FH 10/25 H FH 10/50 H FH II 12/10 H FH II 12/25 H FH II 12/50 H FH II 15/10 H FH II 15/25 H FH II 15/50 H FH II 18/25 H FH II 18/50 H
45055 45056 45057 44905 44906 44907 44908 44909 44910 44915 44916
0 7 4 9 6 3 0 7 3 8 5
10 10 10 12 12 12 15 15 15 18 18
50 50 50 60 60 60 70 70 70 80 80
10 25 50 10 25 50 10 25 50 25 50
M6 M6 M6 M8 M8 M8 M 10 M 10 M 10 M 12 M 12
13 13 13 17 17 17 17 17 17 19 19
50 50 50 50 50 25 25 25 25 20 20
FIRE PREVENTION
Red hot: You will find fire prevention information on page 31.
141
TECHNICAL DATA
High performance anchor FH II-B - zinc plated steel
Type Art.-No. ID approval drill min. drill-hole depth for through xings td [mm] eect. anchoring depth hef [mm] total length max. usable length thread
ETA
do [mm]
l [mm]
t x [mm]
FH 10/10 B FH 10/25 B FH 10/50 B FH II 12/10 B FH II 12/25 B FH II 12/50 B FH II 12/100 B FH II 15/10 B FH II 15/25 B FH II 15/50 B FH II 15/100 B FH II 18/25 B FH II 18/50 B FH II 18/100 B FH II 24/25 B FH II 24/50 B FH II 24/100 B FH II 28/30 B FH II 28/60 B FH II 32/30 B FH II 32/60 B
45001 45002 45003 48773 48774 48775 46832 48776 48777 48778 46835 48779 48780 46841 48886 48887 46842 47547 47548 47549 47550
7 4 1 0 7 4 6 1 8 5 7 2 8 8 7 4 5 8 5 2 8
10 10 10 12 12 12 12 15 15 15 15 18 18 18 24 24 24 28 28 32 32
80 95 120 90 105 130 190 100 115 140 190 130 155 205 150 175 225 180 210 230 260
85 100 125 90 105 130 184 110 125 150 200 135 160 214 167 192 242 196 226 250 280
M6 M6 M6 M8 M8 M8 M8 M 10 M 10 M 10 M 10 M 12 M 12 M 12 M 16 M 16 M 16 M 20 M 20 M 24 M 24
10 10 10 13 13 13 13 17 17 17 17 19 19 19 24 24 24 30 30 36 36
50 50 50 50 50 25 25 25 25 25 20 20 20 10 10 10 5 4 4 4 4
do [mm]
l [mm]
t x [mm]
6 0 1 4 5 2 9 6
10 12 12 15 15 15 18 18
50 60 60 70 70 70 100 100
10 10 25 10 25 50 25 50
M6 M8 M8 M 10 M 10 M 10 M 12 M 12
10 13 13 17 17 17 19 19
50 50 20 50 20 10 10 10
Mean ultimate loads, design resistant and recommended loads for single anchors of scher High performance anchor FH II and FH 10 with large axial and edge distance.
Anchor size FH 10 M6 gvz 50 75 (70)3) 10 16.0 13.5* 9.5 10.8 6.8 7.7 6.9 FH II 12 M8 gvz 60 80 12 29.3* 30.6* (36.1*)2) 15.6 19.2 (23.2)2) 11.2 13.7 (16.6)2) 17.1 FH II 15 M 10 gvz 70 90 15 39.5 48.7* (56.9*)2) 19.7 31.2 (36.8)2) 14.1 22.3 (26.3)2) 34.3 Non-cracked concrete FH II 18 M 12 gvz 80 105 18 48.3 71.1* (82.5*)2) 26.4 45.6 (52.8)2) 18.9 32.6 (37.7) 2) 60.0 = 3 x hef = 1.5 x hef 50 100 50 100 100 12 10 60 100 60 100 120 14 22.5 (17.5)3) 70 100 70 140 140 17 40 (38) 2) 80 160 80 200 160 20 80 100 200 100 220 200 26 160 (123)3) 120 220 120 240 250 30 180 160 360 180 380 300 34 200 FH II 24 M 16 gvz 100 125 24 67.5 148.6* 37.0 73.9 26.4 52.8 152.0 FH II 28 M 20 gvz 125 150 28 94.3 170.4* 51.7 96.8 (103.3)2) 36.9 69.1 (73.8)2) 296.0 FH II 32 M 24 gvz 150 180 32 124.0 223.1* 67.9 119.2 (135.8)2) 48.5 85.1 (97.0)2) 512.0
Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile Shear Design resistant loads NRd and VRd [kN] Tensile Shear Recommended loads Nrec and Vrec [kN] Tensile Shear Recommended bending moment Mrec [Nm] 0 90 0 90 0 90
hef [mm] h1 [mm] d0 [mm] Nu [kN] Vu [kN] NRd [kN] VRd [kN] Nrec [kN] Vrec [kN] Mrec [Nm]
Anchor characteristics Characteristic axial spacing Characteristic edge distance Minimum axial spacing1) Minimum edge distance 1) Minimum structural component thickness Clearance-hole in fixture to be attached Installation torque
Anchor size
Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile Shear Design resistant loads NRd and VRd [kN] Tensile Shear Recommended loads Nrec and Vrec [kN] Tensile Shear Recommended bending moment Mrec [Nm] 0 90 0 90 0 90
hef [mm] h1 [mm] d0 [mm] Nu [kN] Vu [kN] NRd [kN] VRd [kN] Nrec [kN] Vrec [kN] Mrec [Nm]
FH II 12 M8 gvz 60 80 12 21.0 30.6* (36.1*)2) 9.8 19.2 (22.3)2) 7.0 13.7 (15.9)2) 17.1
Cracked concrete FH II 18 M 12 gvz 80 105 18 33.8 71.1* (82.5*)2) 17.1 34.3 12.2 24.5 60.0 = 3 x hef = 1.5 x hef
FH II 24 M 16 gvz 100 125 24 47.3 148.6* 24.0 48.0 17.1 34.3 152.0
FH II 28 M 20 gvz 125 150 28 66.0 170.4* 33.5 67.1 24.0 47.9 296.0
FH II 32 M 24 gvz 150 180 32 86.8 223.1* 44.1 88.2 31.5 63.0 512.0
Anchor characteristics Characteristic axial spacing Characteristic edge distance Minimum axial spacing1) Minimum edge distance 1) Minimum structural component thickness Clearance-hole in fixture to be attached Installation torque
All values apply for non-cracked concrete C20/25 without edge or spacing influences. Design resistant loads: material safety factor M is included. Material safety factor M depends on the type of anchor. Recommended loads: material safety factor M and safety factor for load L = 1.4 are included. * Steel failure decisive. 1) For minimum spacing and minimum edge distance the above described loads have to be reduced (See fischer Technical Handbook or design software CC-COMPUFIX)!
143
LOADS
High performance steel anchors
Mean ultimate loads, design resistant and recommended loads for single anchors of scher High performance anchor FH A4 with large spacing and edge distance.
Anchor type Effective anchorage depth Drill hole depth Drill hole diameter Mean ultimate loads Nu and Vu [kN] Tensile Shear Design resistant loads NRd and VRd [kN] Tensile Shear Recommended loads Nrec and Vrec [kN] Tensile Shear Recommended bending moment Mrec [Nm] Mrec [kN] Anchor characteristics Characteristic spacing Characteristic edge distance Minimum spacing1) Minimum edge distance 1) Minimum structural component thickness Clearance-hole in fixture to be attached Installation torque scr, N ccr, N smin for c cmin for s hmin df T inst [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm] 4.8 12.0 = 3 x hef = 1.5 x hef 50 100 50 100 100 12 10 60 120 60 100 130 14 25 70 190 80 180 140 18 40 80 200 80 240 200 20 80 24.0 42.0 0 90 0 90 0 90 hef [mm] h1 [mm] d0 [mm] Nu [kN] Vu [kN] NRd [kN] VRd [kN] Nrec [kN] Vrec [kN] FH 10 A4 M6 50 75 10 14.1* 19.8* 7.5 7.5 5.4 5.4 FH 12 A4 M8 60 85 12 22.3 29.5* 11.6 11.1 8.3 8.0 FH 15 A4 M 10 70 100 15 34.3 48.3* 18.0 18.2 12.9 13.0 FH 18 x 100 A4 M 12 100 135 18 55.8 71.6* 25.4 26.8 18.1 19.2
All values apply for non-cracked concrete C20/25 without edge or spacing influences. Design resistant loads: material safety factor M is included. Material safety factor M depends on the type of anchor. Recommended loads: material safety factor M and safety factor for load L = 1.4 are included. * Steel failure decisive. 1) For minimum spacing and minimum edge distance the above described loads have to be reduced (See fischer Technical Handbook or design software CC-COMPUFIX)!