The purpose of this set of notes is to give a brief overview of common construction systems for domestic and commercial applications, typically used in the Irish construction industry
Residential Construction
Houses:
Traditionally constructed (in Ireland) using Masonry walls Timber Decking on one way spanning timber joists. (Precast concrete flooring such as T beam and block are also regularly used, mainly for sound-proofing benefit) Duo pitch prefabricated timber roof trusses. (For dormer construction and complicated one off houses, cut roofs with structural steel purlins are commonly used).
In recent years, sustainability issues, improved thermal performance and speed of erection have increased the popularity of timber frame construction.
Structural Design 1
Structural Systems
LVL Joist
Non reinforced masonry is adequate for structures up to 4 stories high. For 5 stories high and above, robustness must be addressed, so masonry (which has no tensile strength) is inadequate. Timber Joists Sizes are adequate for spans up to 6.0m. LVL joists and eco joists are available in deeper sizes than cut timber and hence can span further up to 8.0m see load tables on web sites below;
http://www.dontim-eng.co.uk/products_timber.php4 http://www.gangnail.co.uk/index.php/products/ecojoist
Apartment Blocks
Generally constructed using reinforced masonry walls or insitu/precast concrete walls. Floors are constructed using precast prestressed systems such as, hollowcore or wideslab. Prestressing allows shallower construction than normally reinforced concrete. As floor plans are usually identical for multiple floors of apartment buildings, this type of construction is particularly suitable for precast construction techniques. Heavy construction, such as the systems above, have in-built fire proofing and sound proofing qualities. Some timber frame apartment buildings have been constructed in the UK, currently up to a maximum of 6 stories tall. Fire proofing and Sound proofing are issues which must be overcome in this type of construction.
Structural Design 1
Structural Systems
Hollowcore Units
Wideslab Units
Structural Systems
Commercial clients like to have maximum flexibility to arrange their business they would prefer to have no columns at all if possible. This can be achieved in single storey buildings, but can prove impractical for multi-storey structures For office space over basement carparks, grids in the region of 7.5m X 7.5m are typical. In a retail application, this arrangement may not be desirable to the client. Larger anchor tenants, such as Tesco, Dunnes etc may require minimum grids in the order of 12m X 12m or a rectangular arrangement, say 8m X 16m over a basement carpark. For light industrial/warehousing/manufacturing units, single storey buildings with minimum internal columns are generally employed. Clear spans in excess of 50m are achievable.
Structural Systems
Maximum 2.0 L
1.0
Expensive to construct extra formwork and complicated steel fixing Relatively deep solution Allows good flexibility in terms of possible ope sizes and locations Suitable for heavily loaded areas, such as plant and storage
Structural Systems
Structural Design 1
Structural Systems
Economic to construct Relatively shallow solution Poor flexibility in terms of possible ope sizes and locations May have issues with shear around column locations, when slab subject to heavy loading
Structural Systems
Very expensive to construct Use of bespoke fibreglass formwork Lightweight solution suitable for longer spans than solid reinforced concrete slabs Good flexibility in terms of possible ope sizes and locations Good finish can be achieved no need for false ceiling
Structural Design 1
Structural Systems
Table below by IStructE: Manual for the design of concrete building structures to Eurocode 2 applies to reinforced concrete. It does not apply to prestressed or post tension concrete design
Structural Systems
Precast prestressed slabs on precast (sometimes prestressed) beams/walls supported by precast columns; Flooring Unit Types T beam (pre-stressed) and block has maximum span of up to 6m Wideslab (pre-stressed) has a maximum span of approx. 8m Hollowcore (pre-stressed) and Double Tees (pre-stressed) can span up to 18m Katzenberger / Omnia (reinforced) slabs can span up to 6m
Structural Screeds of 75mm minimum are usually added to the top of precast flooring units. For robustness, horizontal and peripheral ties are generally contained within the screed.
Structural Design 1
Structural Systems
Fast construction time Precast units provide working surface for follow on trades Very economic for multi storey buildings with identical floor plans Reduces trades on site very little shuttering/carpentry required Building design must be finalised prior to fabrication of units little flexibility for change, once production has begun
Structural Systems
Steel Frames can be very similar to precast concrete frames that is precast flooring units spanning onto steel beams, supported by steel columns.
Structural Design 1
Structural Systems
Structural Design 1
Composite Construction
Structural Systems
Alternatively, the steel beams and the concrete screed may be designed as a composite element, if; All beams are designed as simply supported There is sufficient depth and width of screed over the entire length of the beam. Shear Studs are installed to provide the shear connection between the steel and the concrete. When simply supported and subject to vertical load, the top of a beam will be in compression, while the bottom is in tension. Concrete is good in compression, but poor in tension, while steel is very good in tension. Composite design therefore makes efficient use of the material properties of both concrete and steel to produce an economic solution.
Shear Studs welded to top of Composite Steel Beams Slabs can also be designed compositely, by combining a permanent steel shutter (Comflor etc) to resist tension, while the concrete screed resists the compressive stresses.
Structural Design 1
Structural Systems
Engineering G.A. Plan of Composite Deck Floor Fast construction time Very economic for multi storey buildings with identical floor plans Reduces trades on site very little shuttering/carpentry required Decking units are easily cut on site for complex or non-square layouts
Reference Websites for Steel Frame Construction below; http://www.tata.com http://www.amse.ie/index.htm http://www.siac.co.uk/index.jsp?b=0-93&pID=99&nID=133 http://www.duggansteel.ie/ http://www.asdwestok.co.uk/ http://www.kingspanpanels.ie/common/structural/htm/main_index.htm