Product Information
Sw
Dw
DESCRIPTION Worlds most popular expanding shield anchor. Easy to use with good load carrying capacity. Ideal general purpose anchor bolt with excellent tolerance to variation in hole size. The collapsible ferrule ensures positive clamping force is transmitted to the fixture.
ho
FEATURES 1. Provides a projecting stud to support fixture during installation and removal. 2. Ferrule marked with hole diameter for correct installation. 3. Pressed steel segments ensure consistent dimensional accuracy. 4. Optimum taper nut angle for maximum expansion in all substrates.
REFERENCE
PRODUCT CODE
NEW CODE
(Tinst)
(Tinst)
M6 10P M6 25P M6 60P M8 10P M8 25P M8 60P M10 15P M10 30P M10 60P M12 15P M12 30P M12 75P M16 15P M16 35P M16 75P M20 15P M20 30P M20 100P M24 75P M24 120P
M6
M8
M10
M12
M16
M20 M24
65 80 15 75 90 125 90 105 135 110 125 170 150 170 210 170 185 255 255 300
10
12.5
45
13
17
50
17
21
60
19
24
75
24
30
115
30 36
37 50
130 150
10 25 60 10 25 60 15 30 60 15 30 75 15 35 75 15 30 100 75 120
6.5
12
50
35
70
6.5
5.0
9.0
14
55
40
80
15
7.5
11
16
65
50
100
27
13
0 0 10 35 0 10 30 0 75
13
20
85
60
120
50
23
17
25
125
95
190
120
22 26
32 38
140 160
115 125
220 240
230 400
44-505 44-510 44-515 44-555 44-560 44-565 44-605 44-610 44-615 44-655 44-660 44-665 44-705 44-710 44-715 44-755 44-760 44-765 44-805 44-810
PM-06010P PM-06025P PM-06060P PM-08010P PM-08025P PM-08060P PM-10015P PM-10030P PM-10060P PM-12015P PM-12030P PM-12075P PM-16015P PM-16035P PM-16075P PM-20015P PM-20030P PM-20100P PM-24075P PM-24150P
Installation
1. Drill a hole of required diameter and depth. Note: When fixing into brickwork, mortar joints should be avoided.
2. Remove debris and thoroughly clean hole with brush and pump.
3. Remove nut and washer and insert anchor into hole. Position fixture over the thread.
36
Tel: 086 100 RAWL (7295), Fax: +27 (0) 11 894 5189
RAWLBOLT
Specification Data
SIZE
Reduction Factors - Edge and Spacing Distances for Rawlbolt Bolt Projecting The full characteristic edge and spacing distances shown in the table above are the minimum allowable for the quoted DESIGN RESISTANCE or RECOMMENDED LOAD, depending on your design method. Where these dimensions are not achievable,
the appropriate reduction factor/s from the tables below must be applied to the DESIGN RESISTANCE or RECOMMENDED LOAD. Choose the required bolt diameter across the top of the appropriate table and read down the left hand column until actual edge or spacing distance is found. Read off the reduction factor where the two lines intersect (interpolate as required).
Multiply this factor by the DESIGN RESISTANCE or RECOMMENDED LOAD quoted in the table. On the occasion that multiple close edge and/or spacing distances occur, the appropriate reduction factors must be applied.
0.70 0.80 0.70 0.90 0.80 0.70 1.00 0.90 0.80 0.70 1.00 0.90 0.78 1.00 0.85 0.93 1.00
0.50 0.64 0.76 0.50 1.00 0.75 0.50 1.00 0.69 0.50 1.00 0.85 0.93 0.50 1.00 0.55 0.76 0.50 1.00 0.75 0.50 1.00 0.75 1.00
60 80 100 120 150 180 210 250 290 330 370 420
0.70 0.80 0.70 0.90 0.80 0.70 1.00 0.90 0.80 0.70 1.00 0.90 0.78 1.00 0.85 0.93 1.00
Brickwork Application
When installing into brickwork and there is a combined load in tension and shear, the resultant load must not exceed the quoted performance figure. Technical Advisory Service e-mail: rawlsales@rawl.co.za OR rawltechnical@rawl.co.za 37