USER GUIDE & SAFETY MANUAL USER GUIDE & SAFETY MANUAL
CONDUX
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
Read and understand all procedure and safety instructions before using a Condux Running Line
Tensiometer. Observe all safety information on this page and note specific safety requirements as
explained by procedures called out in this manual. Failure to follow these instructions could result in
serious personal injury or death.
ADVERTENCIA:
Favor de leer y comprender todas las instrucciones de operación y seguridad antes de usar la máquina.
Si Ud. no comprende las instrucciones favor de consultarle a su jefe.
(Twist plug/outlet)
(Standard plug/outlet and adapter)
Extension Cords
2. Use only 3-wire extension cords that have 3-prong grounding-type plugs and 3-pole receptacles
that accept the Running Line Tensiometer Electronic Control Box's plug.
Outdoor Use Extension Cords
3. If used outdoors, the extension cord must be marked with the suffix W-A following the cord type
designation (e.g., STJW-A).
4. Use an extension cord with the proper wire size for the length of the cord. An undersized cord will
cause a drop in line voltage, resulting in loss of power and overheating (See Chart below).
Total Amps 0 - 2.0 2.1 - 3.4 3.5 - 5.0 5.1 - 7.0 7.1 - 12.0 12.1 - 16.0 16.1 - 20.0
Ext. Cord Length Wire Size
25 ft. 18 18 18 18 16 14 12
50ft. 18 18 18 16 14 12 10
75 ft. 18 18 16 14 12 10 8
100 ft. 18 16 14 12 10 8 8
150 ft. 16 14 12 12 8 8 6
200 ft. 16 14 12 10 8 6 4
300 ft. 14 12 10 8 6 4 4
400 ft. 12 10 8 6 4 4 2
500 ft. 12 10 8 6 4 2 2
600 ft. 10 8 6 4 2 2 1
800 ft. 10 8 6 4 2 1 0
1000 ft. 8 6 4 2 1 0 0
5. Position the cord so that it will be clear of any rotating parts and will not be a trip hazard to the
operator.
Don't Abuse Electrical Cord
6. Never lift or carry the Running Line Tensiometer Electronic Control Box by the cord, and never
yank the cord to disconnect it from the receptacle. Keep the cord away from heat, oil, and sharp
edges.
7. Do not use the Running Line Tensiometer if the switch is malfunctioning. Have it replaced by an
authorized service center.
Disconnect Tools
8. Always disconnect the power when not in use and before installing, removing, or servicing the
Electronic Control Box.
5
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
General Information
The Condux Running Line Tensiometer, used with the Condux CableGlider®
1.
cable puller (or other rope capstan pullers) will give accurate measurements of
the force exerted on a cable as it is installed. It consists of two components: the
Mechanical Sensing Unit (which mounts directly to the cable puller) and the
Electronic Control Box.
Mechanical Electronic
Sensing Unit Control Box
serial number serial number
Figure 1 Figure 2
RLT w/Chart Recorder 08674212 08674240 08674225 08674240 08674230 08674242 08674232
RLT 08674222 08674241 08674228 08674241 08674235 08674243 08674233
Voltage 110 VAC 60 Hz 220 VAC 60 Hz 110 VAC 60 Hz 220 VAC 60 Hz 110 VAC 60 Hz 220 VAC 60 Hz 12 volt DC
Amperage 20 AMP 11 AMP 10 AMP 5 AMP 10 AMP 5 AMP
Electronic Control Box
Chart Speed 24" (61 cm) per hour 24" (61 cm) per hour 24" (61 cm) per hour 24" (61 cm) per hour
Accuracy ± 5% of full scale ± 5% of full scale ± 5% of full scale ± 5% of full scale
Lbs Accuracy ± 600 lbs (2,669 N) ± 325 lbs (1,445 N) ± 325 lbs (1,445 N) ± 325 lbs (1,445 N)
Length 13.25" (34 cm) 13.25" (34 cm) 13.25" (34 cm) 13.25" (34 cm)
Width 9.25" (24 cm) 9.25" (24 cm) 9.25" (24 cm) 9.25" (24 cm)
Height 12.75" (32 cm) 12.75" (32 cm) 12.75" (32 cm) 12.75" (32 cm)
Weight 18 lbs (8.2 kg) 18 lbs (8.2 kg) 18 lbs (8.2 kg) 18 lbs (8.2 kg)
Rope Dia. .625" - .875" .625" - .875" .625" - .875" .625" - .875"
Sensing Unit
(15 mm - 22 mm) Dia. (15 mm - 22 mm) Dia. (15 mm - 22 mm) Dia. (15 mm - 22 mm) Dia.
Mechanical
Length 21.84" (55 cm) 16.25" (40 cm) 16.25" (40 cm) 16.25" (40 cm)
Width 4.00" (10 cm) 3.25" (8 cm) 3.25" (8 cm) 3.25" (8 cm)
Height 11.00" (26 cm) 8.00" (20 cm) 8.00" (20 cm) 8.00" (20 cm)
Weight 60 lbs (27.3 kg) 32 lbs (14.5 kg) 32 lbs (14.5 kg) 32 lbs (14.5 kg)
Figure 3
6
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
The unit will accommodate pull tape and rope up to and including 7/8" diameter
with an accuracy of ±5% of full scale. Load handling capabilities and other specifi-
cations are determined by the model used. Locate your model (figure 3) and
familiarize yourself with its capabilities.
The Electronic Control Box has a large LED display and programmable overload
setpoint with both an audible and visual indication of an overload condition. The
unit also has the capability to disengage the cable puller when an overload occurs.
A chart recorder (optional) will give you a permanent record of the pull.
Equipment Set-up
Installation of the Mechanical Sensing Unit
2.
The Mechanical Sensing Unit is designed to mount directly to the frame of Condux
CableGlider® cable pullers. Two distinct mounting mechanisms are used for four
cable puller models. Be aware of the model of CableGlider that the
tensiometer is to be used on (CableGlider STD, HD, Plus, and HYD) and follow the
specific instructions for that model. The Mechanical Sensing Unit can also be used
with other rope capstan cable pullers, however, mounting will vary.
Rope Installation
!CAUTION: Running Line Tensiometer is not for use with steel cables
or steel ropes.
Rope must follow a straight path over the cable puller sheaves and through
the tensiometer. Avoid contact between rope and cable puller frame.
Install rope without removing the Mechanical Sensing Unit side plates or
removing the sensing unit from the puller. Simply insert through the unit (figure
6). Arrows indicate direction of travel for inserting rope.
Figure 6
Electronics Connection
!DANGER: The Electronic Control Box is an electrical device. Electric
shock hazards exist that could result in severe personal injury or
death. Observe the following precautions:
• The Electronic Control Box power switch should be in the off position
before connecting or disconnecting any cords.
Connect one end of the sensing cord from the Electronic Control Box to the load
cell mounted on the Mechanical Sensing Unit (figure 7). The 6-pin female con-
nector on the end of the cord mates with the male receptacle located on the
Mechanical Sensing Unit. Connect the other end of the cord to the Electronic
Control Box (figure 8). Before making these connections, ensure the receptacles
are free of dirt and moisture. Do not modify this cord’s length.
Tighten the connector collars over the threaded portion of the receptacles. This
prevents the cord from coming loose during operation. This cord is necessary to
measure the tensions sensed by the load cell.
8
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
Sensing Cord
Connector
Figure 7 Figure 8
Power Connection
Electrical power is supplied to the Electronic Control Box through the power cords
located on the side of the unit. Located directly adjacent to the inlet is an outlet
intended to supply power to the cable puller (figure 8). Plug your puller into this
outlet! The outlet can be programmed to stop the puller when an overload occurs
or it can supply uninterrupted power. With power supplied to the inlet, the outlet is
energized.
The tension limit and other settings are entered using the buttons on the left side
of the Electronic Control Box face plate (figure 9). Follow steps 1-6 to
program the unit. See also figure 10 for a quick reference. For operator
convenience, this figure is reproduced as a label on the inside cover of the
Electronic Control Box.
1. Push the power switch on the Electronic Control Box to the ON position. Be
sure that the sensor and power cords are properly connected (see “Sensor
Connection” and “Power Connection” sections).
2. Select the Rope Size. Press the ROPE DIAMETER SET button until the
correct diameter LED is lit. The meter automatically calibrates to the selected
rope size.
9
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
Figure 9
3. Set the cable Tension Limit. Press and hold the SET TENSION LIMIT UP or
DN buttons to set the desired value. The system resets to the run mode after 5
seconds. Holding a button down will put it into a fast change mode, where the
numbers will ramp up or down quickly.
4. Zero the Display. Press and hold the ZERO DISPLAY button for 1 to 2
seconds to zero the display.
5. Select Audible Alarm. Press the ALARM button ON (LED light is lit) to activate
audible alarm when pulling tensions exceeds preset limit. Press the ALARM
button OFF (LED light is not lit) to disable audible alarm.
6. Select the Puller Control Required. Press the TENSION LIMIT CONTROL
button ON (LED light is lit) to activate the stop the cable puller should the
tension limit is reached. Press the TENSION LIMIT CONTROL button OFF
(LED light is not lit) to disable this function.
CONDUX
®
desired value. The system resets to run mode after five seconds.
N
0 24000 48000
PULLING TENSION
TENSION
LIMIT
CONTROL
• Tension Limit Control: Press ON (LED lit) to activate puller over-
LB
load cutout. Press OFF (LED not lit) to disable puller overload cutout.
N
ON / OFF • Limit Reset: Press button to reset puller overload cutout and
UP
DN LIMIT
RESET audible alarm. This can be done only when the tension is below the
SET TENSION LIMIT PEAK
DISPLAY
ZERO
DISPLAY preset tension limit.
• Alarm: Press ON (LED lit) to activate audible alarm when tension
3/8 1/2 5/8 in ALARM
ROPE DIAMETER
15.88 mm
exceeds preset limit. Press OFF (LED not lit) to disable audible alarm.
9.52 12.7
SET
POWER
ON / OFF
• Zero Display: Press and hold button for two seconds to zero display.
ON
10 Figure 10
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
!NOTE: The Electronic Control Box is factory set to display all pulling forces in
pounds. To change the display to newtons (N), turn the control box off, press and
hold the Limit Reset button while turning the power on. Hold the button down until
the LED light next to the N on the display lights.
Figure 11 Figure 12
PAPER LOADING
1. Turn Chart Recorder power switch OFF and open access door.
2. Press black release latch on right side below scales, pull paper cassette
straight out (figure 12).
3. Remove used paper from front feed tray.
4. Open rear cassette cover and front paper guide / tear bar.
5 Place the new Z-fold paper in the rear feed tray with red line down and
printed side face up (figure 13).
6. Unfold the first few paper leaves and pull them over the steel cylinder
(figure 14).
7. Feed paper between the front paper guide / tear bar and steel cylinder.
8. Place the paper squarely on the steel cylinder and sprockets (figure 15) and
close front paper guide / tear bar. Close the rear cassette cover.
9. Reinstall the paper cassette by sliding the cassette into the chart recorder
and snapping it into place.
11
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
10. Press “E” button to feed Extra paper and ensure the paper is feeding
correctly. Close the access door.
Figure 13 Figure 14
PEN REPLACEMENT
1. Turn Chart Recorder power switch OFF and open access door.
2. Remove paper cassette (see paper loading instructions).
3. Swing lower scale upwards.
4. Carefully pull pen cartridge straight out with fingers or needle nose pliers.
5. Remove cap on new pen cartridge (figure 16).
6. Slide new pen cartridge into holder until it stops. Swing lower scale down.
7. Replace paper cassette. Make sure pen tip contacts paper.
8. Close access door and turn power switch ON.
Figure 15 Figure 16
12
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
Operation Instructions
To operate the Running Line Tensiometer safely and efficiently, the user must
have a working knowledge of the Condux CableGlider Cable puller.
EQUIPMENT PREPARATION
3.
1. Verify that the rope is properly inserted in the sheave grooves (figure 6).
2. Manually tension the rope.
3. Verify that the Mechanical Sensing Unit does not interfere with the cable puller
frame (figure 4, 5).
4. Turn the Electronic Control Box power switch to ON.
5. Verify that the tension limit has been set correctly.
6. Verify that the tension limit control is ON, if overload control is required.
7. Verify that the tension overload alarm is ON, if desired.
8. Verify that the Chart Recorder power switch is ON if a chart recorder is to be
used.
CABLE PULLING PROCEDURES
1. Press the foot switch to start the puller. Slowly remove any slack or excess
pull line. Attend the line coming off the capstan to avoid any tangles, and
keep some tension on the line so that the capstan grips the pull line.
2. Stand at least 3 to 4 feet (0.9 to 1.2 m) away and at a 30 degree angle from
the cable puller capstan. Wear gloves to avoid rope burns and abrasions.
• Do not wrap the pull line around a hand, arm, foot, or leg.
• Always be ready to release the pull line.
3. When the TENSION LIMIT CONTROL is ON, the puller will stop pulling if the
cable tension exceeds the programmed limit of the Electronic Control Box and
the puller is plugged into the Electronic Control Box. Release the foot switch
and the cable or pull-line tension will slowly release.
Many pull lines build up tension from stretching. Never approach or service a
pull line under tension. Always release tension before proceeding.
4. If the pulling operation exceeds the electronic tension limit, correct the cause
for high tension.
13
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
Synthetic fibers are susceptible to degradation and damage in many ways that
are not controllable by the manufacturer. Therefore, it is imperative that the rope
be inspected before use, and if it shows signs of excessive wear it should be
replaced. See rope guidelines on page 5.
Calibration
4.
!NOTE: The Condux Running Line Tensiometer, as with many mea-
suring devices, must be calibrated regularly to ensure its accuracy.
We recommend both the Mechanical Sensing Unit and the Electronic Control Box
be returned to Condux at least once a year for calibration.
The running line tensiometer will be calibrated and shipped back within 48 hours
of receipt. There may be a nominal charge for the recalibration of your running
line tensiometer.
14
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
Troubleshooting Guide
5.
PROBLEM: SOLUTION:
Digital display is not functioning. • Turn Electronic Control Box power switch ON
Digital display does not display expected • If LED light next to “N” is lit, the display is
values. displaying the force in Newtons. Switch the
display to pounds by turning the control box
off, press and hold the LIMIT RESET button
while turning the power on. Hold the button
down until the LED light next to the “lbs” on
the display lights.
Numbers on digital display start counting up • Load cell is not properly connected to the
and do not stop with no load on the rope. electronic control box. Verify all connections
are made and are tight.
Cable puller does not stop when • TENSION LIMIT CONTROL is OFF. Press
programmed tension limit is reached. the TENSION LIMIT CONTROL button ON
(LED light is lit).
Cable puller stops before line tension reaches • Tension limit is not set to desired load. Press
preset load limit programmed into Electronic and hold the SET TENSION LIMIT UP or DN
Control Box. buttons to set the desired value.
Chart paper does not advance. • Check the chart recorder cassette installation.
Chart recorder is not functioning. • Remove the chart recorder from the
Electronic Control Box (4 screws on face
plate) and check pigtail connector for proper
connection.
15
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
6.
User’s Guide & Safety Manual 08674268
User’s Video 08674267
Z-fold paper, 0 to 6,500 lb (0 to 28,900 N)* 02245600
Z-fold paper, 0 to 12,000 lb (0 to 53,400 N)* 02245700
Ink Cartridge, 3 pack (Chessell recorder) 02245800
Ink Cartridge, single (Jumo recorder) 02246001
* Z-fold paper comes 2 paper bundles per package. Each paper bundle is approximately
26 feet (7.8 m) long. At a chart speed of 2 feet (60 cm) per hour, each bundle will last
for approximately 13 hours of continuous operation.
Contact Condux Customer Service for other accessories that may have been added after
the printing of this manual. Additional accessories may be available upon request.
16
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
NOTES
17
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
NOTES
18
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com
5 Blue Heron Drive
Comstar Supply, INC Collegeville, PA 19426
Think Cable... Think Comstar Phone: 610-831-5020
Fax: 610-831-5012
1-866-326-6782 www.comstarsupply.com
Warranty Information
A. FACTORY ASSISTANCE
Condux International can provide further advise regarding any problems with the
installation, service, assembly, or disassembly of the Running Line Tensiometer. Call toll
free at 1-800-533-2077 (USA and Canada) or 1-507-387-6576 and ask for assistance. The
Running Line Tensiometer can be returned to the factory at any time for service or repair;
however, obtain a Return Material Authorization (RMA) must be obtained from Condux
before shipping. Condux will not accept returned items without an RMA.
The running line tensiometer will be calibrated and shipped back within 48 hours of
receipt. There may be a nominal charge for the recalibration of your running line ten-
siometer.
C. LIMITED WARRANTY
Condux International, Inc. extends the following warranty to the original purchaser of these
goods for use, subject to the qualifications indicated:
Condux International, Incorporated warrants to the original purchaser for use that the goods
or any component thereof manufactured by Condux International will be free from defects in
workmanship for a period of one year from the date of purchase, provided such goods are
installed, maintained, and used in accordance with Condux’s written instructions.
Components not manufactured by Condux International but used within the assembly
provided by Condux International are subject to the warranty period as specified by the indi-
vidual manufacturer of said component, provided such goods are installed, maintained, and
used in accordance with Condux’s and the original manufacturer’s written instructions.
Condux’s sole liability and the purchaser’s sole remedy for a failure of goods under this limit-
ed warranty, and for any and all claims arising out of the purchase and use of the goods,
shall be limited to the repair or replacement of the goods that do not conform to this warranty.
To obtain repair or replacement service under the limited warranty, the purchaser must con-
tact the factory for a Return Material Authorization (RMA). Once obtained, send the RMA
along with the defective part or goods, transportation prepaid, to:
Condux International, Inc.
145 Kingswood Road
Mankato, MN 56001 USA
5 Blue Heron Drive Collegeville, PA 19426 (610) 831-5020 Fax: (610) 831-5012
www.comstarsupply.com