Digital pulse laser power supply touch screen operation instruction

Beijing BOAO laser Tech. Co. Ltd Address : Room 1201, Building 2, Yard 1, Shangdi International Pioneer Park, 7th Street ,Shangdi, Haidian District,Beijing, 100085, China Tel:0086-10-82895905 Fax:0086-10-82895922

Touch screen pulse control power introduction


This power supply consist upper computer touch screen and lower computer pulse power supply panel of two parts,the parameters of the pulse control power stored in memory in touch screen,total of 100 set of discharge parameters.Lower position machine uses 32-bit ARM series CPU quickly implement pulse power control,current control precision can reach 0.1 A, the power more stable. Touch screen page has 11 pages, 1st and 2nd page are mainly used to display manufacturer information, 2nd page stay 10s after , enter the monitor page automatically, if want to immediately enter the monitor in the second boot page , you can stay on page 2, press the touch screen anywhere, can enter the page of monitoring. Monitoring, parameter, light and other pages can press the corresponding button, switch to each other. Page switching diagram:
1st open machine page

2nd open machine page

Monitoring

Parameter

Light spot

other

IO input test

IO output test

Change langue

Setting

Choose xenon lamp

gas valve delay

Cleared time

Technical index
1.Control current: 40A-300A 2.Pulse width:0.1ms-20ms

3.Laser frequence:0.1Hz-100Hz 0HZ is inching. Each grade 1Hz 4.Power output frequence 6KW 5.Work environment : input power triphase 220V10%,Use it at the environment temperature below 30 and dry condition , airborne dust <0.01g/m3. Operation method () open machine When the power supply through long-distance transport, the machine should be checked before starting again. 1. Whether printing plate loose or not; 2. Are there signs of falling off the device; 3. At the contact line of the nose whether to loosen; 4. All external connections (power cord, power connection between box) whether correct. When it is determined that all connections are correct, first close the air switch,connect motive power then control circuit connect power, then the touch screen enter the start state, the first thing is the customer's own LOGO, wait 30 seconds then the operation page will appear, first look at the top right corner of the newsletter is bright green, if there are flashing green indicates normal communication, Each parameter is zero or not, if it is zero ,cannot boot up normally. Need to adjust the parameters into the parameter interface then can open machine, press the open the high pressure start,in the process of start will appear ,generatrix charge test fire signal test, beep sound ,work normally,indicate LEM signal normal, fire success ,the machine enter work state normally,it can be used. () each Interface operation method : 1. Monitoring page

1:The whole interface top left is current time ,middle is the name the interface, right is current date,middle left is information of machine work,include the alarm message . Alarm message prompt include not open machine ,use time limit, the firefailure, charging test fault,no hydraulic pressure, over current, Overheating, over-voltage, generatrix charging test, firesignal test,Conduction time is more than the cycle time,close the machine,LEM1 the signal wire break,LEM2 the signal wire break,power too big, work normally. 2: Middle right is the communication information,the below is the xenon lamp choice,have Single lamp 1,Single lamp 2 and Double lamp 3:Left bottom show each parameter ,if need change the parameter you can enter the page of change parameter page,right is the name of each interface,

press can start power high pressure make power work normally

if press show the below window

Press OK can close the power high pressure,wait 1 minute then can close the main power, cannt press OK then close the power immediately,press the cancel can cancel the window.

press the button can enter the interface modification parameter page, as below:

Mainly used to edit various parameters of the discharge parameters number, setup program also established a correspondent name,can determine a product need parameters more convenient and fast, A program number corresponds to a set of parameters, you want to increase the segments number of discharge ,first set up the the segments of discharge,then show the corresponding discharge parameters input box. After change the current parameter,need to press save parameter to save the current the current parameters.

show parameter number, can via the


corresponding parameters of discharge parameters.

button jump out of the

each parameter have a corresponding name, show this group of process


parameters corresponding to the product name. Can show by English and spell

The discharge frequency of current parameters Customers according to their own product material feature to set of the
discharge parameters ,can set arbitrary waveforms in order to achieve welding effect, Choose one at the normal case, if increase or decrease segments of discharge,must change the data first,then can show the corresponding segments input box

The current discharge parameters are saved to the memory button

This one can adjust the motor torque, Generally used for the optical path of the beam expander automatic adjustment, Its minimum is 0.1, the maximum can be adjusted to 3.0, at the motor set,the numerator and denominator of the electronic gear ratio is directly related to the motor in the above beam adjustment box ,the size of the rotation distance adjust 0.1. The larger the ratio adjusting 0.1 every time ,the motor shaft the greater distance.Users can setting up the ideal molecular denominator parameters according to themself needed.

In this page you can look at updated version of touch screen and the control panel,can be used interchange both English and Chinese, and the single Point Compensation,the test of signal input and output,the button of set,

There are :foot switch,over current,overheating,water press signal test,when there is no signal input red light will not change,the red light will be red, green, alternate flash when have signal ,Here we can detect the external input signal whether have foot

switch , overheating, the water pressure. over current, parameters of we use now, 1, 2, 3, 4, can be ignored if dont use.

On this page you can see the entire sequence of operation of the machine,and the good and bad of the control panel,Run led signal light will display whether normal communication between panel and touch screen, Light spot direction : Light spot motor drive signal quality,if display green light when input and charge denote the machine high pressure have started and signal have be sent out, Fire 1.2.3.4 We only use the two-way at double lamp the Fire 1 and fire2 will have a signal output, If it is single light just the fire1 have the signal output,gas valve and Shutter,We can see whether the signal output until depress the foot switch. Buzzer: it will Chirping and red light flicker when the machine break down

This provide clients with a single lamp repair function, now widespread in front of a few relatively strong power, in the case of low frequency can be improved, if the front of points is strong , you can adjust small the percent of the front points,if certain point need stronger you can adjust the percent big. Total points is the number of points of need to marking a products, at the frequency lower case , Single point total multiples: if 14 points are not enough, you can use this function,such as 2 times is 28 points, can be adjusted Product time interval: the time interval after you finished the first products to mark the second product.

This page include 3 parts 1: Reset times : press this button can make the times of monitor page change to zero. The machine begin recounts at next work start 2: Set the gas valve delay ,press the foot switch the gas valve open immediately, after delay gas valve delaycorresponding time,the laser will output.After loose the foot switch, laser stop to output , after the delay set time , gas valve close.

3:

single lamp 1. single lamp 2

Double lamp change-over button, if the single lamp power cannt be changed ,just can use the single lamp 1. In other pages blank key long press 3 seconds, a dialog box will appear

Manufacture set password,the default password is 0 ,press OK enter the page of input limited

In this page customers can change the parameter of the current, frequency, pulse width to make the machine reasonable use.

The installment plan You can set three stages password on this page, you can set a password at every stages,you should notice the data setup , the time of last stage must smaller than the later stage, manufacture set password: can set the manufacture input password,The default password is 0

Supper password : It is a universal password, you use this password when forget other password. Prompt day number:This is the first phase of the password from time to set the number of days If the password does not be relieved , every day have the prompt:

If the time has finished ,not unlock password, program will automatically stop working ,just input the password for this issue will be released can be used normally. Finish these set ,choose the Period of use passwordthen press the OK,the set is successful Control panel connector 1:Shutter directly from the on-board terminal A1 1,2 feet drawn two lines to the Shutter is ok, no external power supply. 2: Drive motor can lead to 5V pulse and direction from the A2 directly to the driver is OK, drive only connect 24V power supply ok, dont worry COM. 5V is cited from the board to the drive

Shutter

Drive Drive signal

To touch screen

(2,3,5 foot)

Motherboard Empty Empty Empty Empty Sensor signal

A1 is the power input end of Motherboard, A2 is the data lines of connecting to touch screenA3 connect the Shutter,just connect 12V and GATE ok. A4 connect the drive motor, 5V PLUSDIR is ok, Adjustable light spot motor torque , A5A6 connect drive signal, A7, A8 connect sensor signal.if is the single lamp power drive signal just connect A5 , Sensor signal only connect A7. IO board connection port

Empty Empty Empty Empty

Remotesensing control area

Data down Data up Cursor up

IO board
Gas valve Fire2 Fire 1 Charge 1 Main input

Cursor down

foot Pressure protection Heat protection

IO board,B1 connect the signal output end ,B2 connect the control of the remote end,B3 connect the signal input end Wiring method of the single lamp power supply

stop
stop

start

empty

Pressure protection

Foot

220V Interface

Gas valve 220V

Fan

Fan

Fan

Xenon lamp