Arthur Holzknecht Vice President, General Manager ETEL, Inc. 333 E. State Parkway Schaumburg, IL 60173 Aholzknecht@etelusa.com Tel: 847.519.3380
Introduction
As the requirements for machine tool productivity, accuracy and dynamic performance have increased, direct drive technology has emerged as an ideal way to meet these demands. Direct drive torque motors, in particular, have been demonstrated to provide significant machine tool performance improvements. In addition to providing high dynamic performance, torque motors can reduce machine cost of ownership, simplify the machine design, and reduce wear and maintenance.
From the point of view of general electrical theory of operation, torque motors are not different from their more conventional counterparts. Therefore, the electrical control requirements are fundamentally the same. However, in many ways the similarities end there. It is their specific differences that give torque motors their unique advantages for machine tool applications. The most unique feature of a torque motor concerns the physical dimensions. They have a relatively large diameter to length ratio, and they also have a rather short axial length. Additionally, torque motors can simultaneously have both a very large OD (outer diameter) and ID (inner diameter), resulting in a motor that is a thin ring. One important outcome of this Fig. 1: Torque motors are frameless kit motors. They characteristic is that the mass is quite low as a consist of a permanent magnet rotor and a laminated function of the diameter. Also, the large stator. diameter allows very high torque to be developed. As an extreme example, a torque motor for a telescope drive was constructed with a diameter of 2.5m, and a length of less than 50mm. This motor produces a continuous torque exceeding 10,000 N-m (1) . For most machine tool applications, diameters of 1m or less are more typically encountered. Torque motors are a type of frameless motor. This means that the motor does not include a housing, bearings, or feedback device. In this sense the motor is a kit motor, meant to be an integral part of the machine structure. To assist in integrating torque motors, they can be provided with a reusable assembly aid called a bridge. The bridge is set at the factory to ensure the proper alignment of the rotor and stator
for assembly. The bridge also keeps the magnetic field contained within the motor, thereby eliminating the need for a special non-ferrous area for assembly, and protecting the rotor from damage from metal scraps or loose screws.
Bridge
Rotor
Stator
Measured stiffness (in the moving direction) of an ETEL motor with a DSA2-PL-D servodrive and a moving mass of 250kg
Torque-Speed Characteristics
Their relatively large number of magnetic pole-pairs distinguishes torque motors. There are consequently a large number of permanent magnets on the rotor. It is this characteristic that enables the motor to be constructed as a thin ring. It also enables torque motors to achieve very smooth velocity regulation, with low ripple. However, eddy current
Stiffness in N/um
1000
Fig. 4: Direct drives increase the dynamic stiffness of machine tools (in this example: >400 N/m at all frequencies, and >1000 N/m below 20 hz)
losses in a brushless motor increase with increased pole-pairs, so this sets a design constraint on their maximum practical number. As a result, torque motors are primarily designed for low speed applications, generally below 1000 RPM. However, this is more than adequate for many machine tool axis drives. Torque motors can produce very high torque at stall, and they are capable of high dynamic stiffness. Hence the common name of torque motor. However, the motor alone does not determine high dynamic stiffness and precision. The benefits of a direct drive motor system are only realized if the machine tool is built to the necessary standards of precision and stiffness, and if the system incorporates a high performance control system.
TMA 0760-070 TMA 0530-150 TMA 0990-030 TMA 0760-050 TMA 0530-100 TMA 0760-030 TMA 0530-070 TMA 0360-150 TMA 0530-050 TMA 0360-100 TMA 0530-030 0 500 1000 1500 2000 2500 3000 3500 4000
cont. Torque @ 80
with cooling
peak torque
Fig 5: Example torque ratings (N-m) for motors with Diameter from 565mm to 795mm and Stator Length from 90mm to 210mm (Courtesy ETEL S.A.)
TMA 0210-050-3TB
180 160 140 Torque [Nm] 120 100 80 60 40 20 0 0 200 400 600 Speed [rpm] Tcw105 [Nm] Drive 300V Tp [Nm] Drive 300V Tcw105 [Nm] Drive 600V Tp [Nm] Drive 600V 800 1000 1200
Intermittent duty
Continuous duty
TMA 0530-100-3VD
Intermittent duty
Continuous duty
500 0 0 20 40 60 80 100 120 140 160 180 Speed [rpm] Tcw105 [Nm] Drive 600V Tp [Nm] Drive 600V
Torque motor with OD = 565mm and Length = 160mm Fig 6: Two examples of Torque-Speed curves for torque motors typically used for machine tool applications. Data is for liquid cooled motors and 600 VDC bus amplifier. (Courtesy ETEL S.A.)
Feedback Considerations
High precision, high-resolution feedback is essential for optimal performance of a direct drive. Because the load is directly coupled to the drive higher accuracy is possible, but the positioning resolution is also in direct relation to the resolution of the feedback system. One needs an optical encoder with a high line count (typically 9000 lines per revolution and above), combined with a high-resolution interpolation factor. Such feedback devices are available from several manufacturers. System resolution below 1 arc-sec is generally required.
Thermal Considerations
Like all DC servomotors, torque motors generate heat in operation. This heat must be effectively removed to eliminate thermally induced machine distortions. Machine tool grade torque motors include provision for liquid cooling to remove heat generated in the stator. Since the liquid flows in close proximity to the stator windings, this is a very efficient method to remove heat. The use of liquid cooling also effectively increases the continuous torque rating of the motor. Air-cooling is also an option. However, it is much less effective than liquid for heat transfer.
Customer housing A Etel Stator Frame B Water Cooling Inlet / Outlet
Seal ( O-Ring )
An important difference between a direct drive system and one driven by a conventional DC servomotor and gearbox, for example, is that the torque motor is mounted internally in the axis and is an integral part of the machine. Therefore, it is much more important to remove the heat. The conventional motor is typically mounted in a less critical location (e.g. at the end of the worm gear), so the heat removal is less of an issue, and the motor can be allowed to run at a higher temperature.
Dynamic torque:
(Nm) (kgm2)
Friction, machining torque, axis configuration (static force due to the weight of offset loads) and external perturbations generate additional torque: Tadd (Nm) Total Torque: Peak torque: Ttot = Tdyn + Tadd (Nm) Tmax = MAX( Ttot ) (Nm)
t cycle
Tcont =
T
0
2 tot
dt
t cycle
(Nm)
For many systems, the motion can be considered as taking place over discrete intervals, allowing the following calculation:
Tcont =
T
k =1
2 k
tk
t cycle
(Nm)
of torque #k
Tk:
discrete
element
Tmax Pp = K m
Tcont Pc = K m
Km =
(W )
(W )
Continuous power :
The heat produced by motor power dissipation must be removed by the cooling system to avoid heating of the machine elements. Under static conditions with an applied load, one must perform more detailed calculations to be sure that one motor phase does not get disproportionately hot, since power dissipation is not shared equally among all three phases in this case.
Cost (normalized at conventional drive = 100%) Mounting/assembly time Position Index time Position repeatability Feedback system resolution Stiffness
Conventional Mechanical Drive 100% 88 hr. 1 sec 2.5 arc-sec 7.2 x 106 N-m/rad
Direct Drive 97% 12 hr. 0.33 sec 1 arc-sec 0.18 arc-sec 13 x 106 N-m/rad
Summary of Key Torque Motor Characteristics for Machine Tool Applications Direct Drive (Direct coupling of the load to the motor, without intervening power transmission elements) High accuracy and repeatability High dynamic performance Servo stiffness High bandwidth No hysteresis Eliminates mechanical power transmission elements (gearboxes, worm gear drives, etc.) High reliability Reduced wear and maintenance High torque and low speed Very smooth motion, with excellent velocity regulation Ultra-low speed operation possible High torque at stall and over the complete speed range Large Diameter to length ratio, short axial length Ring configuration enables optimal configuration of the machine Low mass and inertia Liquid cooling to eliminate heat transfer to the machine structure
Fig. 9: View of the direct drive rotary table on a midsized gear grinder, with an example workpiece.
The use of the direct drive torque motor enables the rotary table to achieve typical dynamic following errors of less than 0.00020 deg (0.72 arc-sec) at a rotational speed of 400 deg/min., which is a typical gear grinding speed. The torque motor has been tested with servo drives from Siemens, Bosch and ETEL.
Fig. 10: Example of the large gears one can grind on a direct drive table. Gears weighing more than 5000kg can be machined. Fig. 11: Example of gear grinder for parts up to 100kg. The B-axis incorporates a torque motor
Case Study 2: Precision multi-axis machining center (O.M.V. S.r.l., Caltana di S. Maria di Sala, Italy) In this application the use of multiple torque motor driven axes enables double milling in a single machine structure with either synchronous machining (two identical workpieces), or independent machining. The machine incorporates a unique double-rotary table configuration. This table is driven by four torque motors with a gantry-mode balanced tilting movement. The 480mm diameter tables can support workpieces of up to 775mm diameter.
Fig. 13: Milling machine incorporating a Double Tilt-rotary table with torque motor drive
Typical applications of the machine include the precision machining of turbofans, and other complex parts in hard to machine alloys. Case Study #3: Combination CNC machining and turning center (Deckel Maho Gildemeister) This application demonstrates the innovative ways machine tool builders are implementing torque motors to expand the versatility of machining centers in ways that were previously unattainable with conventional drives. In this case, the torque motor enables a single machine that is capable of both multi-axis CNC machining and turning. This revolutionary machine has many benefits, including reduced setup time and higher productivity.
Torque in Nm 2000 1800 1600 1400 1200 1000 800
680
Power in kW
S1-100 %
22 19,4
22,5
21,4
20
18,8
100
200
400
RPM
Fig. 15: Both high torque machining and high power turning are accomplished using torque motors
The machine tool builder carefully engineered the integration of the torque motor in the machine. The result is a compact, high performance axis that is an ideal example of the enabling technology benefits of torque motors.
Torque Motor
300
500
References: 1. 2. 3. 4. 5. 6. Wavre, N., et.al. Drive Systems for Demanding Applications, Swiss Quality Production, Carl Hanser Verlag, Munich, Germany, 1998 Raskin, C. Designing with Motion Handbook, Technology 80, Inc. Minneapolis, MN, USA, 1997 Zirn, O. and Baldini, G., Direct Drives in Machine Tools (Direktantriebe in Werkzeugmaschinen), Werkstatt und Betrieb, Vol. 130, No. 4, Carl Hanser Verlag, Munich, Germany, 1997 Favre, E., et.al. Permanent Magnet Syncronous Motors: A Comprehensive Approach to Cogging Torque Suppression, IEEE Transactions on Industry Applications, Vol. 29, No. 6, Nov./Dec. 1993. Direct Drive Motors: Fast and Accurate, Machine Design Magazine, Basics of Design Engineering, February 11, 1999 Banon, L., Feusi, H., Servos with High Torque Motors for Direct Drive, Automation, Motion Drives and Control (AMD&C) International Magazine, May 1997
Acknowledgements: The author would like to gratefully acknowledge the support and cooperation of Hoefler Maschinenbau GmbH, of Ettlingen, Germany, O.M.V. S.r.l., of Caltana di S. Maria di Sala, Italy, and Deckel Maho Gildemeister for the case studies presented in this paper.
About the author: Arthur Holzknecht is the Vice President and General Manager of ETEL, Inc., a leading supplier of direct drive motion control solutions for machine tools and other high tech applications. Prior to joining ETEL, Mr. Holzknecht held positions of Vice President, Sales and Marketing at Etec, a manufacturer of test equipment for MEMS devices, and Director of Marketing and Business Development at Anorad Corp., a manufacturer of sub-micron positioning systems for the semiconductor industry. Mr. Holzknecht holds a B.S.M.E. from the University of Michigan at Ann Arbor.
10