Vous êtes sur la page 1sur 28

Operation Manual

HONET MD5500 Multi-service Distribution Module

Table of Contents

Table of Contents
Example of Integrated Networking Configuration................................................................

26.1 Networking Description.........................................................................................

26.2 Configuration Procedure......................................................................................... 7


26.2.1 Configuring MD5500..................................................................................... 7
26.2.2 Configuring UA5000-1..............................................................................

18

26.2.3 Configuring UA5000-2..............................................................................

20

26.2.4 Configuring UA5000-3..............................................................................

21

26.2.5 Configuring UA5000-4..............................................................................

24

26.2.6 Verifying Configuration Result................................................................... 26

Huawei Technologies Proprietary


i

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

Example of Integrated Networking Configuration


This chapter makes use of examples of integrated networking configuration to introduce the
configuration process of the main services provided by the UA5000.
There are three kinds of networking modes in the examples. In case there is only one networking
mode adopted in the actual situation, you can refer to the relevant part.
In case the UA5000 and the MD5500 are used together to form the network, the narrowband
services should be configured on the MD5500. To describe the data relationship between the
different equipment in detail, this chapter introduces the configuration commands of the MD5500.

26.1 Networking Description


Figure 1.2 is the networking diagram mentioned above, which includes three kinds of
networking modes between the MD5500 and the UA5000, as shown in Table 1.1 .
Table 1.1 List of networking modes between the MD5500 and the UA5000
Networki

Networking description

Cable connection

ng type
IMA

Broadband services of the

The IMA subboard of the APM board of the

networkin

UA5000 are transmitted

UA5000-1 is connected with the AIU board (slot

g mode

upstream to the MD5500


through the IMA links, and
narrowband services of the
UA5000 are transmitted

0) of the MD5500.
The PV8 board of the UA5000-1 is connected
with the CES board (slot 4) of the MD5500.

upstream to the MD5500


through the E1 links.
Detached

Broadband services of the

networkin

UA5000 are transmitted

The APM board of the UA5000-2 is connected


with the AIC board (slot 10) of the MD5500.

g mode of

upstream to the MD5500

broadban

through the 155Mbit/s optical

d and

interface, and narrowband

narrowba

services of the UA5000 are

nd

transmitted upstream to the

The PV8 boards of the UA5000-2 are connected


with the CES boards (slots 5 and 6) of the
MD5500.

MD5500 through the E1 links.

Huawei Technologies Proprietary


1

Operation Manual
HONET MD5500 Multi-service Distribution Module

Networki

Example of Integrated Networking Configuration

Networking description

Cable connection

VP Ring

The MD5500 and the UA5000

The optical interface 0 of the APM board of the

networkin

form the network through VP

UA5000-3 is connected with the optical interface

g mode

Ring. Narrowband and

of the AIC board (slot 11) of the MD5500.

ng type

broadband services of the


UA5000 are transmitted
upstream to the MD5500
together through circuit
emulation.

The optical interface 0 of the APM board of the


UA5000-4 is connected with the optical interface
of the AIC board (slot 12) of the MD5500.
The optical interface 1 of the APM board of the
UA5000-3 is connected with the optical interface
1 of the APM board of the UA5000-4.
The PV4 board of the UA5000-3 is connected
with the CES subboard of the APM board of the
UA5000-3.
The PV4 board of the UA5000-4 is connected
with the CES subboard of the APM board of the
UA5000-4.

Huawei Technologies Proprietary


2

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

NMS
ATM

PSTN

IP

MD5500
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15

UA5000-1
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17

P T C A
W S S S
X S L L

D
S
L

A
I
U

P P A
V V P
8 8 M

C C C A A
E E E S S
S S S X X

A A A A E I
I I I I P P
C C C C U U

IMA E1
E1
UA5000-2
00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17

P T CA
W S S S
X S L L

D
S
L

P P A
V V P
8 8 M

VP Ring 622M
UA5000-3

UA5000-4

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17

P T A A
W S D S
X S L L

Splitter
Modem

D
S
L

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17

P T AA
W S DS
X S L L

P P A
V V P
4 4 M

D
S
L

H P P A
W V V P
C 4 4 M

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17

RSP

Figure 1.2

P
W
X

A A
3 3
2 2

D
S
L

R R
S S
P P

Integrated networking diagram of the UA5000 and the MD5500

Some associated data of the MD5500 and the UA5000 in this networking application is shown in
Table 2.1
Table 2.1

Data planning

Equipmen

MD5500

UA5000-1

UA5000-2

UA5000-3

UA5000-4

t
Frame No.

frame 0

frame 1

frame 2

frame 3

frame 4

Frame type

MD5500B

UAM_V(HUBM)

UAM_V(HUBM)

UAM_V(HUBM)

UAM_V(HUBM)

NMS

10.11.104.1

10.11.104.1

10.11.104.1

10.11.104.1

10.11.104.1

ETH

10.11.104.2

169.254.39.1

169.254.39.1

169.254.39.1

169.254.39.1

interface

Huawei Technologies Proprietary


3

Operation Manual
HONET MD5500 Multi-service Distribution Module

Equipmen

MD5500

Example of Integrated Networking Configuration

UA5000-1

UA5000-2

IPoA: 10.50.1.2

IPoA: 10.50.1.3

UA5000-3

UA5000-4

t
Inband NM

IPoA:

IPoA: 10.50.1.4

IPoA: 10.50.1.5

10.50.1.1
0/0
groupindex=0
VPI=0

0/11
groupindex=0
VPI=0 VCI=100

VCI=100
0/10/0

0/11/0

VPI=0

VPI=0 VCI=100

VCI=100
0/11/0

0/11/0

VPI=1

VPI=1 VCI=100

VCI=100
0/11/0

0/11/0

VPI=5

VPI=5 VCI=100

VCI=100
Clock

Clock source
0: bits0,

Clock source 0:

Clock source 0:

Clock source 0:

Clock source 1:

ATM port 0/11/2

ATM port

ATM port 0/11/0

ATM port 0/11/0

0/11/0

Clock source 1:

Clock source 2:

ATM port 0/11/1

ATM port 0/11/1

Clock source
1: bits1,
Clock source
2: E1 port
0/4/16
(connected
with LE),
Clock source
3: E1 port
0/5/16
(connected
with LE)
Inter-frame

0/4/24

1/9/01/9/3

link

0/4/27,

1/10/01/10/3

0/4/280/4/31
0/5/200/5/23

2/9/02/9/3

0/6/200/6/23

2/10/02/10/3

Huawei Technologies Proprietary


4

Operation Manual
HONET MD5500 Multi-service Distribution Module

Equipmen

MD5500

Example of Integrated Networking Configuration

UA5000-1

UA5000-2

UA5000-3

UA5000-4

t
0/6/00/6/3,

3/9/03/9/3,

0/6/40/6/7

3/10/03/10/3

PVC: 0/11/0

PVC: 0/11/0

VPI=13

VPI=13 VCI=32

VCI=3239

39

Inter-frame

0/6/80/6/11,

4/9/04/9/3,

link

0/6/120/6/15

4/10/04/10/3

PVC: 0/11/0

PVC: 0/11/0

VPI=14

VPI=14

VCI=3239
IMA

VCI=3239

groupindex=0

groupindex=0

version1.1

version1.1

minTxLinks=
1
minRxLinks=
1
clock=ctc
imaid=0
Framelength
=128
clockmode=s
ystem

minTxLinks=1
minRxLinks=1
clock=itc
imaid=0
Framelength=1
28
clockmode=line

Link: 07

Link: 07

Huawei Technologies Proprietary


5

Operation Manual
HONET MD5500 Multi-service Distribution Module

Equipmen

MD5500

Example of Integrated Networking Configuration

UA5000-1

UA5000-2

UA5000-3

UA5000-4

t
VP Ring

Working

Working entity:

Working entity:

entity: 0/11/0,

0/11/0

0/11/0

Protection

Protection entity:

Protection

entity: 0/12/0

0/11/1

entity: 0/11/1

VPG: 1

VPG: 1

Point-to-Point

VPI: 1, 2, 3,

VPI: 1, 2, 3, 13

13

Channel: VPI=1

Channel:

Service PVC:

VPI=1

(PP) channel:
VPI=1
PP PVP: VPI=1,
13

VPI=1, 13

Service PVC:
VPI=1, 13
VPG: 2

PP channel:
VPI=5

VPI: 5, 6, 7,
14

PP PVP: VPI=5,
14

Channel:

VPG: 2
VPI: 5, 6, 7, 14
Channel: VPI=5
Service PVC:

VPI=5

VPI=5, 14

Service PVC:
VPI=5, 14
Process of

Transmitted

Transmitted

Transmitted

ADSL

through AIC

upstream after

upstream after the

upstream after

service on

board

the EPU

IPU terminates

the IPU

PVC

terminates PVC

the

terminates PVC

Transmitted

MD5500

The type of the frame marked as RSP in the networking diagram is RSP_14
(HIB), and its serial number on the MD5500 is frame 5.

NMS is connected with the ETH interface of the ASX board of the MD5500.

Based on the above data planning, the H512CESH must be installed at slot 6
of the MD5500, and H511CESH, H512CESH or H511DT16 can be installed at
slots 4 and 5 of the MD5500.

In the command line prompt, the PV4 board is shown as PV8.

Huawei Technologies Proprietary


6

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

26.2 Configuration Procedure


26.2.1

Configuring MD5500
I. Confirming board
MD5500>enable
MD5500#configure terminal
MD5500(config)#board confirm 0

II.

Configuring VP Ring

Configure ports 0/11/0 and 0/12/0 of the MD5500 as VP Ring port. Two VPGs are configured.
The VPG with vp_group_id of 1 corresponds to the UA5000-3. Set the VPI of the VPL as 1, 2, 3,
and 13, and set the VPI of the channel as 1.
The VPG with vp_group_id of 2 corresponds to the UA5000-4. Set the VPI of the VPL as 5, 6, 7,
and 14, and set the VPI of the channel as 5.
MD5500(config)#vpring add 0 0 0/11/0 0/12/0
MD5500(config)#aps
MD5500(config-aps)#aps vpg 1 work-if 0/11/0 protect-if 0/12/0
MD5500(config-aps)#aps vpl 1 1
MD5500(config-aps)#aps vpl 1 2
MD5500(config-aps)#aps vpl 1 3
MD5500(config-aps)#aps vpl 1 13

MD5500(config-aps)#aps channel 1 interface atm 0/11/0 w_leaf 1


MD5500(config-aps)#aps channel 1 interface atm 0/12/0 p_leaf 1
MD5500(config-aps)#aps enable 1

MD5500(config-aps)#aps vpg 2 work-if 0/11/0 protect-if 0/12/0


MD5500(config-aps)#aps vpl 2 5

Huawei Technologies Proprietary


7

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

MD5500(config-aps)#aps vpl 2 6
MD5500(config-aps)#aps vpl 2 7
MD5500(config-aps)#aps vpl 2 14

MD5500(config-aps)#aps channel 5 interface atm 0/11/0 w_leaf 2


MD5500(config-aps)#aps channel 5 interface atm 0/12/0 p_leaf 2
MD5500(config-aps)#aps enable 2

MD5500(config-aps)#exit

III.

Configuring IMA service

Add an IMA group to the AIU board (at slot 0) with both IMA groupindex and IMA ID of 0, clock
mode of CTC and IMA frame length of 128. After that, add IMA links 07 to IMA group 0.
MD5500(config)#interface aiu 0/0
MD5500(config-if-aiu-0/0)#sub-interface ima
MD5500(config-if-aiu-0/0.ima)#ima group add 0 version1.1 1 1 ctc 0 128
MD5500(config-if- aiu-0/0.ima)#ima group mode clockmode 0 system
MD5500(config-if-aiu-0/0.ima)#ima link add 0 0
MD5500(config-if-aiu-0/0.ima)#ima link add 0 1

MD5500(config-if-aiu-0/0.ima)#ima link add 0 7


MD5500(config-if-aiu-0/0.ima)#exit
MD5500(config-if-aiu-0/0)#exit

IV.

Configuration NMS

MD5500(config)#atmlan ip-address ethernet 10.11.104.2 255.255.255.0


MD5500(config)#atmlan netif 10.50.1.1 255.255.255.0
MD5500(config)#atmlan ip-access 10.50.1.1 10.50.1.10 255.255.255.0
MD5500(config)#atmlan ip-access 10.11.104.1 10.11.104.255 255.255.255.0

Huawei Technologies Proprietary


8

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

MD5500(config)#atmlan firewall ethernet


MD5500(config)#atmlan arp ipoa 10.50.1.2 0/0 groupindex 0 0 100 2 2
MD5500(config)#atmlan arp ipoa 10.50.1.3 0/10/0 0 100 2 2
MD5500(config)#atmlan arp ipoa 10.50.1.4 0/11/0 1 100 2 2
MD5500(config)#atmlan arp ipoa 10.50.1.5 0/11/0 5 100 2 2
MD5500(config)#nms name huawei 10.11.104.1 public private
MD5500(config)#nms activate name huawei

V.

Configuring working mode and port mode of CES board


MD5500(config)#interface ces 0/4
MD5500(config-if-ces-0/4)#runmode tdm
MD5500(config-if-ces-0/4)#crc4 16 off
MD5500(config-if-ces-0/4)#crc4 17 off
MD5500(config-if-ces-0/4)#crc4 18 off
MD5500(config-if-ces-0/4)#crc4 19 off
MD5500(config-if-ces-0/4)#exit

MD5500(config)#interface ces 0/5


MD5500(config-if-ces-0/5)#runmode tdm
MD5500(config-if-ces-0/5)#crc4 16 off
MD5500(config-if-ces-0/5)#crc4 17 off
MD5500(config-if-ces-0/5)#crc4 18 off
MD5500(config-if-ces-0/5)#crc4 19 off
MD5500(config-if-ces-0/5)#exit
MD5500(config)#interface ces 0/6
MD5500(config-if-ces-0/6)#runmode tdm
MD5500(config-if-ces-0/6)#exit

Huawei Technologies Proprietary


9

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

VI. Configuring system clock


MD5500(config)#clock source 0 bits0 e1
MD5500(config)#clock source 1 bits1 e1
MD5500(config)#clock source 2 0/4/16
MD5500(config)#clock source 3 0/5/16
MD5500(config)#clock priority tdm 0/1/2/3
MD5500(config)#clock priority sdh 0/1/2/3

VII. Configuring V5 interfaces


MD5500(config)#interface v5 0
MD5500(config-if-v5-0)#if-v5 attribute an_v5 v52 0 0
MD5500(config-if-v5-0)#link add 0/4/16 1
MD5500(config-if-v5-0)#link add 0/4/17 3
MD5500(config-if-v5-0)#link add 0/4/18 5
MD5500(config-if-v5-0)#link add 0/4/19 7
MD5500(config-if-v5-0)#link add 0/5/16 2
MD5500(config-if-v5-0)#link add 0/5/17 4
MD5500(config-if-v5-0)#link add 0/5/18 6
MD5500(config-if-v5-0)#link add 0/5/19 8
MD5500(config-if-v5-0)#c-channel add 0/4/16 tsno 16 1:protc1_act 0
MD5500(config-if-v5-0)#c-channel add 0/5/16 tsno 16 2:protc1_std
MD5500(config-if-v5-0)#c-channel add 0/4/17 tsno 16 3:protc2_act 1
MD5500(config-if-v5-0)#c-channel add 0/5/17 tsno 16 4:protc2_std
MD5500(config-if-v5-0)#isdn-channel add isdn_ds 1
MD5500(config-if-v5-0)#reset
MD5500(config-if-v5-0)#exit

Huawei Technologies Proprietary


10

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

VIII. Configuring PVCs required by inter-frame link between the MD5500


and the UA5000
The VPI corresponding to ports 0/5/00/5/7 is 13, which is used to connect the UA5000-3. The
VPI corresponding to ports 0/6/00/6/7 is 14, which is used to connect the UA5000-4.
MD5500(config)#pvc ces-udt 0/6/0 atm 0/11/0 vpi 13 vci 32 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/1 atm 0/11/0 vpi 13 vci 33 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/2 atm 0/11/0 vpi 13 vci 34 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/3 atm 0/11/0 vpi 13 vci 35 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/4 atm 0/11/0 vpi 13 vci 36 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/5 atm 0/11/0 vpi 13 vci 37 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/6 atm 0/11/0 vpi 13 vci 38 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/7 atm 0/11/0 vpi 13 vci 39 rx-cttr 1 upc off tx-cttr 1 upc off

MD5500(config)#pvc ces-udt 0/6/8 atm 0/11/0 vpi 14 vci 32 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/9 atm 0/11/0 vpi 14 vci 33 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/10 atm 0/11/0 vpi 14 vci 34 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/11 atm 0/11/0 vpi 14 vci 35 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/12 atm 0/11/0 vpi 14 vci 36 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/13 atm 0/11/0 vpi 14 vci 37 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/14 atm 0/11/0 vpi 14 vci 38 rx-cttr 1 upc off tx-cttr 1 upc off
MD5500(config)#pvc ces-udt 0/6/15 atm 0/11/0 vpi 14 vci 39 rx-cttr 1 upc off tx-cttr 1 upc off

IX. Adding frames


MD5500(config)#frame add 1 18
MD5500(config)#frame add 2 18
MD5500(config)#frame add 3 18
MD5500(config)#frame add 4 18
MD5500(config)#frame add 5 2

Huawei Technologies Proprietary


11

Operation Manual
HONET MD5500 Multi-service Distribution Module

X.

Example of Integrated Networking Configuration

Configuring frame links


MD5500(config)#frame link start 0/4/24 end 1/9/0
MD5500(config)#frame link start 0/4/25 end 1/9/1
MD5500(config)#frame link start 0/4/26 end 1/9/2
MD5500(config)#frame link start 0/4/27 end 1/9/3
MD5500(config)#frame link start 0/4/28 end 1/10/0
MD5500(config)#frame link start 0/4/29 end 1/10/1
MD5500(config)#frame link start 0/4/30 end 1/10/2
MD5500(config)#frame link start 0/4/31 end 1/10/3

MD5500(config)#frame link start 0/5/20 end 2/9/0


MD5500(config)#frame link start 0/5/21 end 2/9/1
MD5500(config)#frame link start 0/5/22 end 2/9/2
MD5500(config)#frame link start 0/5/23 end 2/9/3
MD5500(config)#frame link start 0/6/20 end 2/10/0
MD5500(config)#frame link start 0/6/21 end 2/10/1
MD5500(config)#frame link start 0/6/22 end 2/10/2
MD5500(config)#frame link start 0/6/23 end 2/10/3
MD5500(config)#frame link start 0/6/0 end 3/9/0
MD5500(config)#frame link start 0/6/1 end 3/9/1
MD5500(config)#frame link start 0/6/2 end 3/9/2
MD5500(config)#frame link start 0/6/3 end 3/9/3
MD5500(config)#frame link start 0/6/4 end 3/10/0
MD5500(config)#frame link start 0/6/5 end 3/10/1
MD5500(config)#frame link start 0/6/6 end 3/10/2
MD5500(config)#frame link start 0/6/7 end 3/10/3

Huawei Technologies Proprietary


12

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

MD5500(config)#frame link start 0/6/8 end 4/9/0


MD5500(config)#frame link start 0/6/9 end 4/9/1
MD5500(config)#frame link start 0/6/10 end 4/9/2
MD5500(config)#frame link start 0/6/11 end 4/9/3
MD5500(config)#frame link start 0/6/12 end 4/10/0
MD5500(config)#frame link start 0/6/13 end 4/10/1
MD5500(config)#frame link start 0/6/14 end 4/10/2
MD5500(config)#frame link start 0/6/15 end 4/10/3

MD5500(config)#frame link start 4/9/16 end 5/9/0


MD5500(config)#frame link start 4/9/17 end 5/9/1
MD5500(config)#frame link start 4/9/18 end 5/10/0
MD5500(config)#frame link start 4/9/19 end 5/10/1

XI. Configuring subscriber boards


MD5500(config)#board add 1/3 asl
MD5500(config)#board add 1/4 asl
MD5500(config)#board add 1/6 dsl

MD5500(config)#board add 2/3 asl


MD5500(config)#board add 2/4 asl
MD5500(config)#board add 2/6 dsl

MD5500(config)#board add 3/4 asl


MD5500(config)#board add 3/6 asl

MD5500(config)#board add 4/4 asl

Huawei Technologies Proprietary


13

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

MD5500(config)#board add 4/6 dsl

MD5500(config)#board add 5/3 a32


MD5500(config)#board add 5/4 a32
MD5500(config)#board add 5/6 dsl

MD5500(config)#board confirm 1
MD5500(config)#board confirm 2
MD5500(config)#board confirm 3
MD5500(config)#board confirm 4
MD5500(config)#board confirm 5

XII. Configuring test groups


MD5500(config)#test
MD5500(config-test)#testgroup set 1/2
MD5500(config-test)#testgroup set 2/2
MD5500(config-test)#testgroup set 3/2
MD5500(config-test)#testgroup set 4/2
MD5500(config-test)#exit
MD5500(config)#frame set 1 testgroup 1
MD5500(config)#frame set 2 testgroup 2
MD5500(config)#frame set 3 testgroup 3
MD5500(config)#frame set 4 testgroup 4
MD5500(config)#frame set 5 testgroup 4

XIII.

Configuring EMU
MD5500(config)#emu add 0 h303esc 1 30 random
MD5500(config)#emu add 1 h303esc 2 30 random
MD5500(config)#emu add 2 h303esc 3 30 random

Huawei Technologies Proprietary


14

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

MD5500(config)#emu add 3 h303esc 4 30 random

XIV. Configuring the type of power supply to be monitored (suppose all


the power supplies are 4810 power supply)
MD5500(config)#interface emu 0
MD5500(config-if-h303esc-0)#esc power powertype 2:4810
MD5500(config-if-h303esc-0)#exit
MD5500(config)#interface emu 1
MD5500(config-if-h303esc-1)#esc power powertype 2:4810
MD5500(config-if-h303esc-1)#exit
MD5500(config)#interface emu 2
MD5500(config-if-h303esc-2)#esc power powertype 2:4810
MD5500(config-if-h303esc-2)#exit
MD5500(config)#interface emu 3
MD5500(config-if-h303esc-3)#esc power powertype 2:4810
MD5500(config-if-h303esc-3)#exit

XV. Configuring narrowband subscribers


MD5500(config)#narrow user
MD5500(config-narrow-user)#pstnuser add 1/3/0 0 1000 telno 1000000

MD5500(config-narrow-user)#pstnuser add 2/3/0 0 2000 telno 2000000

MD5500(config-narrow-user)#pstnuser add 3/4/0 0 3000 telno 3000000

MD5500(config-narrow-user)#pstnuser add 4/4/0 0 4000 telno 4000000

MD5500(config-narrow-user)#pstnuser add 5/3/0 0 5000 telno 5000000

Huawei Technologies Proprietary


15

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

MD5500(config-narrow-user)#exit

XVI.

Configuring flow control parameters

MD5500(config)#traffic table index 5 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr 2048


cdvt 10000000 enpPDisc off enePDisc off
MD5500(config)#traffic table index 6 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr 8000
cdvt 10000000 enpPDisc off enePDisc off
UA5000(config)#traffic table index 7 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr
20000 cdvt 10000000 enpPDisc off enePDisc off
UA5000(config)#traffic table index 8 srvcategory cbr tdtype noClpNoScr clp01Pcr 20000

XVII. Configuring EPU board


MD5500(config)#interface epu-fast-ethernet 0/14/0
MD5500(config-if-fast-ethernet-epu-0/14/0)#port np
MD5500(config-if-fast-ethernet-epu-0/14/0)#mode 100full
MD5500(config-if-fast-ethernet-epu-0/14/0)#no shutdown
MD5500(config-if-fast-ethernet-epu-0/14/0)#exit

XVIII. Configuring subscriber data transmitted upstream through EPU


MD5500(config)#pvc atm 0/9/0 vpi 0 vci 32 atm 0/14/8 vpi 0 vci 256 cast-type p2p rx-cttr 6
upc off tx-cttr 6 upc off
MD5500(config)#interface epu-fast-ethernet 0/14/0
MD5500(config-if-fast-ethernet-epu-0/14/0)#pvc 0 256
MD5500(config-if-pvc(0,256))#no shutdown
MD5500(config-if-pvc(0,256))#exit
MD5500(config-if-fast-ethernet-epu-0/14/0)#exit

XIX. Configuring PPPoE subscriber data transmitted upstream through


IPU
MD5500(config)#interface fast-ethernet 0/15/0
MD5500(config-if-fast-ethernet-0/15/0)#ip address 10.1.1.1 255.255.255.0 //The interface

Huawei Technologies Proprietary


16

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

address is configured according to the planned data.


MD5500(config-if-fast-ethernet-0/15/0)#ip address 10.1.2.1 255.255.255.0 secondary
MD5500(config-if-fast-ethernet-0/15/0)#exit
MD5500(config)#ip route 0.0.0.0 0.0.0.0 10.1.1.2

//The interface address is configured

according to the planned data.


MD5500(config)#pvc atm 0/11/0 vpi 1 vci 32 atm 0/15/8 vpi 0 vci 256 cast-type p2p rx-cttr 6
upc off tx-cttr 6 upc off
MD5500(config)#interface virtual-template 1
MD5500(config-if-virtual-template-1)#ppp authentication chap
MD5500(config-if-virtual-template-1)#exit
MD5500(config)#vpdn-group 1
MD5500(config-vpdn)#accept dialin PPPoE virtual-template 1
MD5500(config-vpdn)#exit
MD5500(config)#aaa
MD5500(config-aaa)#ip-pool 1 10.1.10.1 10 255.255.255.0

//The IP address pool is

configured according to the planned data.


MD5500(config-aaa)#exit
MD5500(config)#interface atm 0/15/8.1
MD5500(config-if-atm-0/15/8.1)#pvc 0 256
MD5500(config-if-pvc(0,256))#protocol PPPoE
MD5500(config-if-pvc(0,256))#exit
MD5500(config-if-atm-0/15/8.1)#exit
MD5500(config)#user-group name huawei

//The user group is configured according to the

actual planning.
MD5500(config-usergroup-huawei)#use ip-pool 1
MD5500(config-usergroup-huawei)#dns primary 10.10.1.1

//The IP address of DNS is

configured according to the actual planning.


MD5500(config-usergroup-huawei)#ppp-user temp0 123456
MD5500(config-usergroup-huawei)#exit

Huawei Technologies Proprietary


17

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

MD5500(config)#pvc atm 0/11/0 vpi 1 vci 33 atm 0/15/8 vpi 0 vci 257 cast-type p2p rx-cttr 6
upc off tx-cttr 6 upc off
MD5500(config)#interface atm 0/15/8.1
MD5500(config-if-atm-0/15/8.1)# pvc 0 257
MD5500(config-if-pvc(0,257))#protocol PPPoE
MD5500(config-if-pvc(0,257))#exit
MD5500(config-if-atm-0/15/8.1)#exit
MD5500(config)#user-group name huawei
MD5500(config-usergroup-huawei)#ppp-user temp1 123456
MD5500(config-usergroup-huawei)#exit

XX. Configuring subscriber data transmitted upstream through AIC


MD5500(config)#pvc ima 0/0 groupindex 0 vpi 0 vci 32 atm 0/13/0 vpi 1 vci 32 cast-type p2p
rx-cttr 6 upc off tx-cttr 6 upc off

MD5500(config)#save

26.2.2

Configuring UA5000-1
I. Confirming board
UA5000>enable
UA5000#configure terminal
UA5000(config)#board confirm 0

II.

Configuring IMA service

Add an IMA group to the APM board with both IMA groupindex and IMA ID of 0, clock mode of
ITC and IMA frame length of 128. After that, add IMA links 07 to IMA group 0.
UA5000(config)#interface apm 0/11
UA5000(config-if-apm-0/11)#sub-interface ima
UA5000(config-if-apm-0/11.ima)#ima group add 0 version1.1 1 1 itc 0 128 2 2 1

Huawei Technologies Proprietary


18

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

UA5000(config-if-apm-0/11.ima)#ima group mode clockmode 0 line


UA5000(config-if-apm-0/11.ima)#ima link add 0 0
UA5000(config-if-apm-0/11.ima)#ima link add 0 1

UA5000(config-if-apm-0/11.ima)#ima link add 0 7


UA5000(config-if-apm-0/11.ima)#exit
UA5000(config-if-apm-0/11)#exit

III. Configuring NMS


UA5000(config)#atmlan ip-address ethernet 169.254.39.1 255.255.255.0
UA5000(config)#atmlan netif 10.50.1.2 255.255.255.0
UA5000(config)#atmlan ip-access 10.50.1.1 10.50.1.10 255.255.255.0
UA5000(config)#atmlan ip-access 169.254.39.1 169.254.39.255 255.255.255.0
UA5000(config)#atmlan firewall ethernet
UA5000(config)#atmlan arp ipoa 10.50.1.1 0/11 groupindex 0 0 100 2 2
UA5000(config)#nms name huawei 10.11.104.1 public private
UA5000(config)#nms activate name huawei
UA5000(config)#atmlan ip-route 10.11.104.0 255.255.255.0 10.50.1.1
UA5000(config)#atmlan ip-access 10.11.104.1 10.11.104.10 255.255.255.0

IV. Configuring system clock


UA5000(config)#clock source 0 0/11/2
UA5000(config)#clock priority 0

V.

Configuring flow control parameters

UA5000(config)#traffic table index 5 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr 2048


cdvt 10000000 enpPDisc off enePDisc off
UA5000(config)#traffic table index 6 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr 8000
cdvt 10000000 enpPDisc off enePDisc off

Huawei Technologies Proprietary


19

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

VI. Configuring subscriber data transmitted upstream through AIC of the


MD5500
UA5000(config)#pvc adsl 0/3/0 vpi 0 vci 35 ima 0/11 groupindex 0 vpi 0 vci 32 rx-cttr 6 upc
off tx-cttr 6 upc off

UA5000(config)#save

26.2.3

Configuring UA5000-2
I. Confirming board
UA5000>enable
UA5000#configure terminal
UA5000(config)#board confirm 0

II.

Configuring NMS

UA5000(config)#atmlan ip-address ethernet 169.254.39.1 255.255.255.0


UA5000(config)#atmlan netif 10.50.1.3 255.255.255.0
UA5000(config)#atmlan ip-access 10.50.1.1 10.50.1.10 255.255.255.0
UA5000(config)#atmlan ip-access 169.254.39.1 169.254.39.255 255.255.255.0
UA5000(config)#atmlan firewall ethernet
UA5000(config)#atmlan arp ipoa 10.50.1.1 0/11/0 0 100 2 2
UA5000(config)#nms name huawei 10.11.104.1 public private
UA5000(config)#nms activate name huawei
UA5000(config)#atmlan ip-route 10.11.104.0 255.255.255.0 10.50.1.1
UA5000(config)#atmlan ip-access 10.11.104.1 10.11.104.10 255.255.255.0

III. Configuring system clock


UA5000(config)#clock source 0 0/11/0
UA5000(config)#clock priority 0

Huawei Technologies Proprietary


20

Operation Manual
HONET MD5500 Multi-service Distribution Module

IV.

Example of Integrated Networking Configuration

Configuring flow control parameters

UA5000(config)#traffic table index 5 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr 2048


cdvt 10000000 enpPDisc off enePDisc off
UA5000(config)#traffic table index 6 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr 8000
cdvt 10000000 enpPDisc off enePDisc off

V.

Configuring subscriber data transmitted upstream through EPU of the


MD5500

UA5000(config)#pvc adsl 0/3/0 vpi 0 vci 35 atm 0/11/0 vpi 0 vci 32 cast-type p2p rx-cttr 6
upc off tx-cttr 6 upc off

UA5000(config)#save

26.2.4

Configuring UA5000-3
I. Confirming board
UA5000>enable
UA5000#configure terminal
UA5000(config)#board confirm 0

II.

Configuring VP Ring

Configure the ports 0/11/0 and 0/11/1 of the UA5000-2 as VP Ring ports.
Configure one VPG with vp_group_id of 1. Set the VPI of the VPL as 1, 2, 3, and 13, and set the
VPI of the channel as 1.
Configure PP channel with vp_group_id of 2 and VPI of 5, corresponding to the UA5000-3.
UA5000(config)#vpring add 0 1 0/11/0 0/11/1
UA5000(config)#aps
UA5000(config-aps)#aps vpg 1 work-if 0/11/0 protect-if 0/11/1
UA5000(config-aps)#aps vpl 1 1
UA5000(config-aps)#aps vpl 1 2
UA5000(config-aps)#aps vpl 1 3

Huawei Technologies Proprietary


21

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

UA5000(config-aps)#aps vpl 1 13

UA5000(config-aps)#aps channel 1 interface atm 0/11/0 w_leaf 1


UA5000(config-aps)#aps channel 1 interface atm 0/11/1 p_leaf 1
UA5000(config-aps)#aps enable 1

UA5000(config-aps)#aps channel 5 interface atm 0/11/0 p2p 2


UA5000(config-aps)#aps channel 5 interface atm 0/11/1 p2p 2
UA5000(config-aps)#exit

III. Configuring NMS


UA5000(config)#atmlan ip-address ethernet 169.254.39.1 255.255.255.0
UA5000(config)#atmlan netif 10.50.1.4 255.255.255.0
UA5000(config)#atmlan ip-access 10.50.1.1 10.50.1.10 255.255.255.0
UA5000(config)#atmlan ip-access 169.254.39.1 169.254.39.255 255.255.255.0
UA5000(config)#atmlan firewall ethernet
UA5000(config)#atmlan arp ipoa 10.50.1.1 0/11/0 1 100 2 2
UA5000(config)#nms name huawei 10.11.104.1 public private
UA5000(config)#nms activate name huawei
UA5000(config)#atmlan ip-route 10.11.104.0 255.255.255.0 10.50.1.1
UA5000(config)#atmlan ip-access 10.11.104.1 10.11.104.10 255.255.255.0

IV. Configuring system clock


UA5000(config)#clock source 0 0/11/0
UA5000(config)#clock source 1 0/11/1
UA5000(config)#clock priority 0/1

V.

Configuring PVC corresponding to frame link

UA5000(config)#pvc atm 0/11/0 vpi 13 vci 32 ces-udt 0/11/2 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 13 vci 33 ces-udt 0/11/3 rx-cttr 1 upc off tx-cttr 1 upc off
Huawei Technologies Proprietary
22

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

UA5000(config)#pvc atm 0/11/0 vpi 13 vci 34 ces-udt 0/11/4 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 13 vci 35 ces-udt 0/11/5 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 13 vci 36 ces-udt 0/11/6 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 13 vci 37 ces-udt 0/11/7 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 13 vci 38 ces-udt 0/11/8 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 13 vci 39 ces-udt 0/11/9 rx-cttr 1 upc off tx-cttr 1 upc off

VI.

Configuring flow control parameters

UA5000(config)#traffic table index 5 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr 2048


cdvt 10000000 enpPDisc off enePDisc off
UA5000(config)#traffic table index 6 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr 8000
cdvt 10000000 enpPDisc off enePDisc off
UA5000(config)#traffic table index 7 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr
20000 cdvt 10000000 enpPDisc off enePDisc off
UA5000(config)#traffic table index 8 srvcategory cbr tdtype noClpNoScr clp01Pcr 20000

VII. Configuring PP PVP


UA5000(config)#pvp atm 0/11/0 vpi 5 atm 0/11/1 vpi 5 cast-type p2p rx-cttr 7 upc off tx-cttr 7
upc off
UA5000(config)#pvp atm 0/11/0 vpi 14 atm 0/11/1 vpi 14 cast-type p2p rx-cttr 8 upc off txcttr 8 upc off

VIII. Configuring PPPoE subscriber data transmitted upstream through


IPU of the MD5500
UA5000(config)#pvc adsl 0/3/0 vpi 0 vci 35 atm 0/11/0 vpi 1 vci 32 cast-type p2p rx-cttr 6
upc off tx-cttr 6 upc off

UA5000(config)#save

Huawei Technologies Proprietary


23

Operation Manual
HONET MD5500 Multi-service Distribution Module

26.2.5

Example of Integrated Networking Configuration

Configuring UA5000-4
I. Confirming board
UA5000>enable
UA5000#configure terminal
UA5000(config)#board confirm 0

II.

Configuring VP Ring

Configure the ports 0/11/0 and 0/11/1 of the UA5000-3 as VP Ring ports.
Configure one VPG with vp_group_id of 2. Set the VPI of the VPL as 5, 6, 7, and 14, and set the
VPI of the channel as 5.
Configure PP channel with vp_group_id of 1 and VPI of 1, corresponding to the UA5000-2.
UA5000(config)#vpring add 0 2 0/11/0 0/11/1
UA5000(config)#aps
UA5000(config-aps)#aps vpg 2 work-if 0/11/0 protect-if 0/11/1
UA5000(config-aps)#aps vpl 2 5
UA5000(config-aps)#aps vpl 2 6
UA5000(config-aps)#aps vpl 2 7
UA5000(config-aps)#aps vpl 2 14

UA5000(config-aps)#aps channel 5 interface atm 0/11/0 w_leaf 2


UA5000(config-aps)#aps channel 5 interface atm 0/11/1 p_leaf 2
UA5000(config-aps)#aps enable 2
UA5000(config-aps)#aps channel 1 interface atm 0/11/0 p2p 1
UA5000(config-aps)#aps channel 1 interface atm 0/11/1 p2p 1
UA5000(config-aps)#exit

III. Configuring NMS


UA5000(config)#atmlan ip-address ethernet 169.254.39.1 255.255.255.0

Huawei Technologies Proprietary


24

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

UA5000(config)#atmlan netif 10.50.1.5 255.255.255.0


UA5000(config)#atmlan ip-access 10.50.1.1 10.50.1.10 255.255.255.0
UA5000(config)#atmlan ip-access 169.254.39.1 169.254.39.255 255.255.255.0
UA5000(config)#atmlan firewall ethernet
UA5000(config)#atmlan arp ipoa 10.50.1.1 0/11/0 5 100 2 2
UA5000(config)#nms name huawei 10.11.104.1 public private
UA5000(config)#nms activate name huawei
UA5000(config)#atmlan ip-route 10.11.104.0 255.255.255.0 10.50.1.1
UA5000(config)#atmlan ip-access 10.11.104.1 10.11.104.10 255.255.255.0

IV. Configuring system clock


UA5000(config)#clock source 0 0/11/0
UA5000(config)#clock source 1 0/11/1
UA5000(config)#clock priority 0/1

V.

Configuring PVC corresponding to frame link

UA5000(config)#pvc atm 0/11/0 vpi 14 vci 32 ces-udt 0/11/2 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 14 vci 33 ces-udt 0/11/3 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 14 vci 34 ces-udt 0/11/4 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 14 vci 35 ces-udt 0/11/5 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 14 vci 36 ces-udt 0/11/6 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 14 vci 37 ces-udt 0/11/7 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 14 vci 38 ces-udt 0/11/8 rx-cttr 1 upc off tx-cttr 1 upc off
UA5000(config)#pvc atm 0/11/0 vpi 14 vci 39 ces-udt 0/11/9 rx-cttr 1 upc off tx-cttr 1 upc off

VI.

Configuring flow control parameters

UA5000(config)#traffic table index 5 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr 2048


cdvt 10000000 enpPDisc off enePDisc off
UA5000(config)#traffic table index 6 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr 8000
cdvt 10000000 enpPDisc off enePDisc off

Huawei Technologies Proprietary


25

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

UA5000(config)#traffic table index 7 srvcategory ubr tdtype noclpnoScrcdvt clp01Pcr


20000 cdvt 10000000 enpPDisc off enePDisc off
UA5000(config)#traffic table index 8 srvcategory cbr tdtype noClpNoScr clp01Pcr 20000

VII. Configuring PP PVP


UA5000(config)#pvp atm 0/11/0 vpi 1 atm 0/11/1 vpi 1 cast-type p2p rx-cttr 7 upc off tx-cttr 7
upc off
UA5000(config)#pvp atm 0/11/0 vpi 13 atm 0/11/1 vpi 13 cast-type p2p rx-cttr 8 upc off txcttr 8 upc off

VIII. Configuring PPPoE subscriber data transmitted upstream through


IPU of the MD5500
UA5000(config)#pvc adsl 0/3/0 vpi 0 vci 35 atm 0/11/0 vpi 5 vci 32 cast-type p2p rx-cttr 6
upc off tx-cttr 6 upc off

UA5000(config)#save

26.2.6

Verifying Configuration Result


I. Verifying NMS
MD5500>enable
MD5500#ping b 10.50.1.2
MD5500#ping b 10.50.1.3
MD5500#ping b 10.50.1.4
MD5500#ping b 10.50.1.5

In addition, pinging the network segment 10.50.1.110.50.1.5 from the NMS should be
successful.

II.

Showing clock
MD5500#show clock mode tdm
MD5500#show clock mode sdh
UA5000#show clock mode
Huawei Technologies Proprietary
26

Operation Manual
HONET MD5500 Multi-service Distribution Module

Example of Integrated Networking Configuration

All clocks should work in trace mode.

III. Verifying frame link


MD5500#show frame info
Check if all frames are in normal state.

IV.

Verifying service

By using ADSL terminal, the user can ping the upstream interface of the MD5500 successfully.
The POTS subscribers can make calls normally.

V.

Verifying V5 interface protection switchover

Perform protection switchover to logic C channel of the V5 interface. The operation should be
implemented successfully.
MD5500#configure terminal
MD5500(config)#interface v5 0
MD5500(config-if-v5-0)#switch-over 0 2 16

VI. Verifying VP Ring protection function


MD5500(config-if-v5-0)#exit
MD5500(config)#aps
MD5500(config-aps)#aps control 1 ms-w
MD5500(config-aps)#aps control 1 ms-p
MD5500(config-aps)#aps control 2 ms-w
MD5500(config-aps)#aps control 2 ms-p
The service shall be switched normally.

Huawei Technologies Proprietary


27

Vous aimerez peut-être aussi