Vous êtes sur la page 1sur 8

Here is Your Customized Document

Your Configuration is: 1. Initialize your VNX Model - VNX5300 Storage Type - VNX for Block (SAN) Server Operating System - Windows Server 2008 Document ID - 1361552946453

Reporting Problems To send comments or report errors regarding this document, please email: usercustomizeddocs@emc.com. For Issues not related to this document, contact your service provider. Refer to Document ID: 1361552946453 Content Creation Date February 22, 2013

Initializing Your VNX

This document describes how to initialize your EMC VNX platform. Major topics include:
Initializing the storage system...............................................................................................................................3

Initializing the storage system

Initializing the storage system


After the storage system is fully powered up for the first time, use the Unisphere Storage System Initialization Wizard to initialize the storage system. Initialization sets the network parameters for storage-system management and creates a management user account for the storage system so you can manage it over the LAN.

Before you start


To complete this procedure, you will need:

The management port and login information in the Planning Worksheets section of the system install guide that shipped with your system. This information includes:
Note: The worksheets can also be obtained from the Recommended Resources section of the Support By Product Page located on the Support.EMC.com website.

A static IP address for each storage processor in the system (for example, http://123.45.6.7). The IPv6 global prefix and gateway for each SP if your network supports the IPv6 Internet Protocol and you want to manually configure IPv6 for the management ports. The subnet mask of the LAN to which the system is connected. The default gateway address of the LAN to which the system is connected.

The system hardware product ID/serial number (TLA S/N) on the tag that is hanging from the back top right corner of a disk processor enclosure (Figure 1 on page 3).

Figure 1. Location of the storage-system product ID/serial number on the DPE

A host on the same subnet as the storage-system management ports. This requirement is for initialization only. The host should support a minimum screen resolution of 1024 x 768 and 256 colors with small fonts. If the host is behind a firewall, the UDP port 2162 (outgoing) and 2163 (incoming), which the initialization wizard uses, must be open for the wizard to function properly. Contact your network administrator to determine if

Initializing the storage system

Initializing the storage system

these ports are open. If these two ports are not open, have your network administrator open the ports.

Installing the Unisphere Storage System Initialization Wizard


Installation prerequisites To initialize a system using the Unisphere Storage System Initialization Wizard, the server must:

Be running a supported version of the operating system. Be connected to the same subnet as the 10 / 100 management ports of the system that you want to initialize. This server may also have Fibre Channel connections to the system.

If you have an earlier version of the initialization wizard installed, you must uninstall it before installing an updated version. Installing the Unisphere Storage System Initialization Wizard on a Windows host or a Windows virtual machine We recommend that you download and install the most recent version of the Unisphere Storage System Initialization Wizard software from the VNX Series support by product page on the EMC Online Support website. 1. Log in as the administrator (or someone who has administrative privileges) to the Windows host or a Windows virtual machine that is on the same subnet as the system. 2. Download the software: a. From the EMC Online Support website search for the link to download the software. b. Select the initialization wizard, and then select the option to save the zip file to your host. c. Double-click the following executable file to start the installation wizard: UnisphereInitTool-Win-32-x86-language-version-build.exe where:
language is either en_US, when only the English version is available, or loc, when

the localized versions are available (including English).


version and build are the version number and the build number of the software.

3. Follow the instructions on the installation screens to install the initialization wizard. A user interface (UI) and a text-based version and a command line version of the wizard are installed.

Initializing Your VNX

Initializing the storage system

4. When the installation is complete, click Done to exit the wizard. 5. If your host is behind a firewall, open the UDP port 2162 (outgoing) and port 2163 (incoming). These ports are used by the initialization wizard. If these ports are not opened, the initialization wizard will not function properly. Contact your network administrator to determine if these ports are open. If these two ports are not open, have your network administrator open the ports.

Running the Unisphere Storage System Initialization Wizard


You can start the initialization wizard from the server on which it is installed. The initialization wizard has three methods for executing commands a user interface (UI) version, a command line interface that can be scripted, or a text-based utility that cannot be scripted. Before continuing, make sure that the system is powered up completely.
Note: For system initialization, connect the server from which you are running the wizard and the system to the same network subnet. Once you have assigned an IP address to the system, the server and system can be on different subnets.

Starting the initialization wizard UI on a Windows server or a Windows virtual machine To start the initialization wizard, select Start All Programs EMC Unisphere Unisphere Storage System Initialization . Using the UI version of the initialization wizard on a Windows host or a Windows virtual machine After you start the wizard, it automatically scans the subnet for supported systems. When this system discovery operation is complete, the utility lists, by hardware product ID/serial number, all uninitialized and initialized systems it found. The hardware product ID/serial number is on a hanging tag at the rear of the system. If the discovery operation did not find the system you are installing, verify that the systems management ports are properly cabled to the LAN on which the host resides. The management ports and the host must both reside on the same physical subnet. Proceed through the wizard screens, providing information where required. For more information about completing the wizard, click Help in the wizards menu bar. If you entered an SP IP address for the first time or changed an SP IP address, the utility reboots the system, and the SP fault light on the back of each SP starts blinking. The reboot takes several minutes to complete. When it has completed, the SP fault light (LED) on each SP stops blinking and remains off.

Running the Unisphere Storage System Initialization Wizard

Initializing the storage system

Starting the text-based or command line initialization wizard on a Windows server or a Windows virtual machine

To start the text-based version, at a command prompt enter cd C:\Program


Files\EMC\Unisphere Storage System Initialization or cd C:\Program Files (x86)\EMC\Unisphere Storage System Initialization; then enter InitToolCLI.exe.

To start the command line version, at a command prompt enter cd C:\Program


Files\EMC\Unisphere Storage System Initialization or cd C:\Program Files (x86)\EMC\Unisphere Storage System Initialization; then enter InitToolCLI.exe

and any of the command line switches listed for the initialization wizard in the EMC VNX Command Line Interface Reference for Block .

Verifying the storage-system initialization


Verify that the storage system was initialized successfully by logging into Unisphere .

Starting Unisphere
1. Log in to a host (which can be a server) that is connected through a network to the systems management ports and that has an Internet browser: Microsoft Internet Explorer, Netscape, or Mozilla. 2. Start the browser. 3. In the browser window, enter the IP address of one of the following that is in the same domain as the systems that you want to manage:

A system SP with the most recent version of the VNX Operating Environment (OE) installed
Note: This SP can be in one of the systems that you want to manage.

A Unisphere management station with the most recent Unisphere Server and UIs installed

Note: If you do not have a supported version of the JRE installed, you will be directed to the Sun website where you can select a supported version to download. For information on the supported JRE versions for your version of Unisphere, refer to Environment and System Requirements in the Unisphere release notes on the EMC Online Support website.

4. Enter your user name and password.

Initializing Your VNX

Initializing the storage system

5. Select Use LDAP if you are using an LDAP-based directory server to authenticate user credentials. If you select the Use LDAP option, do not include the domain name. When you select the LDAP option, the username / password entries are mapped to an external LDAP or Active Directory server for authentication. Username / password pairs whose roles are not mapped to the external directory will be denied access. If the user credentials are valid, Unisphere stores them as the default credentials. 6. Select Options to specify the scope of the systems to be managed.
Global (default) indicates that all systems in the domain and any remote domains can be managed. Local indicates that only the targeted system can be managed.

7. Click Login. When the user credentials are successfully authenticated, Unisphere stores them as the default credentials and the specified system is added to the list of managed systems in the Local domain. 8. If you are prompted to add the system to a domain, add it now. The first time that you log in to a system, you are prompted to add the system to a Unisphere domain. If the system is the first one, create a domain for it. If you already have systems in a domain, you can either add the new system to the existing domain or create a new domain for it. For details on adding the system to a domain, use the Unisphere help.

Initializing the storage system

Copyright 2012 EMC Corporation. All rights reserved. Published 2012 EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS." EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. For the most up-to-date regulatory document for your product line, go to the Technical Documentation and Advisories section on EMC Powerlink. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. All other trademarks used herein are the property of their respective owners. Corporate Headquarters: Hopkinton, MA 01748-9103

Initializing Your VNX

Vous aimerez peut-être aussi