INSTRUCTION MANUAL INSTALLATION, OPERATION & MAINTENANCE

HYDRODYNE NON SEAL CANNED MOTOR PUMP TYPE HD BASIC PUMP

PRECAUTIONS
Please read this manual carefully prior to using the pump. Keep the manual in a location easily accessible to anyone using the equipment. The manufacturer bears no responsibility of using the Equipment at specifications other than original specifications
1

Page

-0-

DO NOT RUN DRY FOR MORE THAN 3 SECONDS


Overheating and internal failure will occur if the pump is run dry for more than 3 seconds.

CHECK DIRECTION OF ROTATION AND BEARING MONITOR


Allow sufficient space at the rear of the motor for viewing direction of rotation and check the dial of bearing monitor regularly.

VENTING BEFORE START


Before start, be sure to vent (air and vapors) entire pump and motor unit properly by opening the air vent valve provided on rear bearing housing. Failure to do so may block circulation flow resulting in excessive heat and wear of motor.

USE PUMP ONLY FOR THE SERVICE OUTLINED ON THE DATA SHEET
Avoid for operating conditions other than those mentioned on the specification data sheet for safe operation of the pump.

PROVIDE PROPER PIPE SUPPORTS


The pump base is designed to support motor weight during operation and maintenance will not support piping loads.

THERMOSTATS MUST BE CONNECTED


If the thermostats are not connected, overheating and burnout of the motor windings may occur due to loss of suction, blocked discharge, loss of cooling flow to jackets etc.

DISASSEMBLY
Turn off or before disassembly to avoid electrical shock. If the pump is handling corrosive or hazardous fluid complete flushing with water to be done before disassembly.

DO NOT OPERATE UNDER FOLLOWING CONDITIONS


Bearing monitor red zone Fluid leakage from any joints Blocked discharge and suction lines Below minimum flow rate as specified in the specification data sheet Without solving out the cause when the protective device works and pump is stopped

-1-

TABLE OF CONTENTS
TITLE INTRODUCTION Basic Type HD Construction SECTION 1 INSTALLATION Inspection Suction & Discharge Piping Electrical Wiring SECTION 2 OPERATION Preparation for starting Start up Procedure Routine Inspection during Operation Procedure to stop Starting after extended period of non use Minimum Flow Rate SECTION 3 MAINTENANCE Daily Check Periodic check Bearing Replacement SECTION 4 SAFETY FEATURES Bearing Monitor (Mechanical) E-Monitor Dry run protection Thermowell SECTION 5 ASSEMBLY AND DISASSEMBLY SECTION 6 TROUBLESHOOTING CHART 36 27 23 24 25 20 21 22 15 15 17 17 18 19 6 7 9 PAGE 3 3

-2-

INTRODUCTION
The instructions in this manual are provided to aid in installation, operation and servicing of the pump. The manual should be read entirely for proper and safe handling of the pump before any maintenance and start up is attempted.

BASIC TYPE HD CONSTRUCTION


The type HD Basic pump is the standard model of Hydrodyne non-seal canned motor pump and is suitable for a broad range of clean, non-volatile liquids for moderate temperatures (upto 80C) and low vapour pressure. It generally consists of a hollow shaft which provides return passage for the motor coolant medium to the suction end of the pump and prevents vapour collection at the bearing. The basic pump has large variety of applications which includes water, acids, chemicals, alcohol, salts solution etc. The shaft is protected on both the ends by hardened shaft sleeves that fit inside the two journal bearings. Thrust washers are installed on either end of the rotor shaft to center the rotor during start up and shut down and during the process of operation. Axial thrust is balanced during normal operation by impeller feedback holes and fixed and variable orifices. The shaft sleeves are available in variety of materials to suit the sprcific fluid applications. Replaced when bearings are changed for maintaining new wear surfaces and clearances The rotor and stator windings are sealed by SS316L or Hastalloy can. A Mechanical bearing monitor is installed in the motor end of the pump. The monitor helps to detect the bearing wear and corrosion. In all instances, a heat exchanger is required for motor cooling. The motor is protected by thermostat embedded in the windings. The operating point of thermostat is determined by the insulation class of the motor.

Basic Model Cut Section -3-

PRINCIPLE OF OPERATION OF BASIC PUMP

-4-

-5-

CROSS SECTIONAL DRAWING OF BASIC PUMP

I. INSTALLATION
1. INSPECTION :
At the time of unloading the pump inspect the shipping container for any damage if any visible damage is seen it should be note. If possible photograph the damage which would be helpful if the extent of damage is uncertain. While receiving the pump, check if required spares, accessories and instruction manual are made available. Note the item no of spares and accessories. Do not remove the seal at the pump suction and discharge side, to avoid entry of foreign particle into the pump. Care should be taken while unloading the pump for any damage.

2. SUCTION AND DISCHARGE PIPING:


The pump should be located as near to the supply tank as possible to lower the NPSH required. Also allow sufficient working area around the pump for maintenance and disassembly. All piping must be supported independent of the pump. Please take care not to load the pump with the weight of piping. Avoid all unnecessary elbow, bends and fittings as they increase frictional losses in the piping. For pipes of different diameter, use expander or reducer as required to prevent air pocket. Fix a pressure gauge on the suction and discharge side of the pump to monitor operation as shown in fig. 1(b). It is extremely helpful at the time of start up and for monitoring the performance of the pump. Use a strainer of 60 to 80 meshes if entry of particles is expected at steady operation. Since Strainer will offer resistance to the flow it is important to select strainer of proper mesh. Depending on particle sizes and it should be cleaned at suitable intervals to prevent clogging of the strainer. Special attention should be paid to keep suction piping air tight in order to avoid air entrapment and also to satisfy the condition of NPSH. The use of elbows near the suction flange should be avoided. When used, elbows should have a large radius. A straight pipe run of atleast ten times the diameter of pipe is recommended between and elbow and the suction flange.

-6-

Fig. 1(a) Example of Pipe Supports

Fig. 1(b): Typical Piping Arrangement

3. ELECTRICAL WIRING:
Normally, direct line starting is used for the canned motor pump because starting current is low and start up time is short. If a low starting current must be maintained because of other existing electrical equipment or for some other reason, transformer starting or reactor starting may be used instead. Starter type:A magnetic type contact switch should be used as the main control switch. This Arrangement not only provides protection in the event of overload, but also thermal protection of the motor windings can be achieved by connecting the thermostats in series with exciting coil in the switch. Properly sized circuit breakers and fuses must be uses on all 3 phases. Motor full load amp. Value is shown in the specification data sheet
3 AC

MCCB F MC A THR OFF THR ON MC

CONTROL POWER SOURCE

M C C B --- MOLDED CASE CIRCUIT BREAKER F MC THR A --- FUSE --- ELECTROMAGNATIC COTRACTOR --- THERMAL RELAY --- AMMETER

THERMOSTAT

MC

SEALLESS PUMP

Fig. 2: Electrical Wiring

-7-

B. Thermostat Protection: A thermostat is located in the hot spots of the windings where the winding temperature is the highest, the purpose of which is to protect the motor windings from overheating. Thermostat is usually of closed contact type which will open out as at the precautionary preset temperature causing the motor protection circuit to trip off the motor. It is installed in canned motor pump as a standard feature Class of insulation Class H Class C Thermostat operating temperature 180 5C 210 5C

TABLE-2 THERMOSTAT OPERATING TEMPERATURE The thermostat has normally closed contact (NC) contacts that open when the motor winding temperature reaches the rated value.

Fig.3 : Thermostat
11 KW - 15 KW (TWO THERMOSTATS)
18.5 KW - 75 KW (THREE THERMOSTATS)

0.75 KW - 2.2 KW (ONE THERMOSTAT)

3.7 KW - 9 KW (ONE THERMOSTAT)

T1

T2

Terminals to be used U. V. W. T1. T2.

T1

T2

T1

T2

T3

T1 T2

T3 T4

Terminals to be used U. V. W. T1. T2.

Terminals to be used U. V. W. T1 - T3.

Terminals to be used U. V. W. T1 - T4.

Fig. 4: Connection Diagram of Motor Winding and Thermostat

-8-

C. Terminal Box :
Figure: 7 Shows the standard terminal box of the HYDRODYNE SEALLESS PUMP. 1. The terminal assembly and terminal designation are as shown below.

For power For thermostat

U, V, W T1, T2, T3, T4

Lead opening the terminal box has two openings for power and thermostat connections. Each standard port size is shown in table as follows For Thermostat BSP QTY 1 2 1 1 1 1 18 12 24 12 4 4 Fig.5: Flameproof Terminal box

Motor Kw 0.75 - 15 18.5 - 75 NO. 27A 27B 27C 61 62 65 66 67 68 69 123 124

For Power 1 BSP 2 BSP

DESCRIPTION TERMINAL BOX GASKET GASKET COVER TERMINAL SUPPORT TERMINAL PLATE WASHER NUT WASHER NUT ALLEN CAP SCREW ALLEN CAP SCREW

-9-

D. Insulation & Winding Resistance:Measure the following insulation resistance Use a 500 V meager for measuring Insulation resistances before carrying out wiring. 1) Points at which insulation resistance is to be measured (a) Winding (b) Thermostat (c) Thermostat 2) : To ground : To ground : To winding

The allowable insulation resistance should be more than 2 M NOTE : At the time of shipment Insulation resistance should be higher than 100 M

Measuring Winding Resistance:During operations if the overload relay or thermostat is activated and motor trips, determine the cause before attempting to restart the pump. Measure the insulation resistance and winding resistance only after removing the cause.

Fig. 8: Measurement of Winding Resistance

Fig. 6: Measuring Winding Resistance

- 10 -

E. Wiring: Connect the power supply Red wire to U, Yellow wire to V and Blue wire to W Check direction of rotation as shown in Section : 3 Operation Use cable gland to prevent ingress of rain water Take care to prevent entry of water into the terminal box in case of outdoor installation. After completing wiring start the pump only as describe in the section operation.

Fig. 7: Power Supply Phases and Terminal Connection

Fig. 8: Example of Cable Gland

- 11 -

Motor Size

Motor Output KW
0.75 1.5 2.2 2.6 3.7 5.5 7.5 9 11 12 15 18.5 22 26 30 37 45 50 60

Voltage

Rated Current

Apparent input KVA


1.74 3.45 5.67 4.89 5.73 8.94 10.89 12.94 15.84 18.70 21.57 26.67 32.0 37.36 43.4 53.16 65.37 71.84 89.75 107.67

Starting Current A
8.4 15.6 22.1 27.2 32 43.75 69.92 81 99 110 135 148 160 182 234 245 270 340 400 488

Starting Input KVA


6.10 11.21 19.84 19.56 22.93 31.31 50.09 58.24 71.29 84.17 97.05 106.68 118.72 130.76 169.26 175.96 196.11 244.26 297.08 349.93

Starting Time Sec

Insulation Class

A
2.4 4.8 6.3 6.8 8 12.5 15.2 18 22 24 30 37 44 52 60 74 90 100 120 150

FRAME I FRAME II

Within 0.5 sec

FRAME III

Within 0.7 sec H,C

415

FRAME IV

Within 1 sec

FRAME V

75

TABLE 3:- 2-POLE MOTOR ELECTRICAL CHARACTERISTICS

- 12 -

III. Operations of Canned Motor Pump


Dry Running of Canned Pump is not permitted (Refer to Figure)

Do not operate under the following conditions : Blocked discharge and suction lines Below minimum flow rate Insufficient NPSH due to clogged suction Strainer, low tank level, flow too high, etc. Reverse rotation.

Do not run dry !


Fig. 9: Dry Running

Shutoff operation should be limited to less than 1 min (Refer to Figure)


shut-off operation

Fig. 10: Shut-off operation

The normal direction of rotation of the standard SEALLESS PUMP is Counterclockwise as viewed from the pump side and clockwise as viewed from the motor side. The direction of rotation is reverse if shutoff pressure is below sixty to seventy percent of that give in the test result table. In this case, stop operation immediately and connect the power leads correctly interchange the two leads.

Direction of Rotation

Fig. 11: Direction of Rotation - 13 -

1. Preparation for starting : Verify that suction & discharge valves are closed. Open the suction valve, allowing the suction piping and pump to fill with liquid to fill with liquid. Open the discharge valve slightly to bleed air from the pump.

Suction valve fully-opened

Fig.12: Venting out air inside pump


B ut to n

2. Start-up procedure : Open the suction valve fully. With the discharge side valve closed, jog the motor 3 times at about 30 second intervals. Jog is an operation which is stopping immediately after applying. Power for 2 ~ 3 seconds. Apply power continuously after making sure there is no unusual noise or vibration during jogging operation. . Make sure that the discharge pressure reaches the rated pressure of the pump with the pressure gauge in the discharge line. Open the discharge valve slowly allowing the discharge capacity to increase to the specified capacity.

O
ON

-O

FF

Fig. 13: Jogging

Note: The direction of rotation is reverse if shut-off head is below sixty or seventy percent of that given in the test results table. In this case, stop operation immediately and connect the power leads correctly; interchange the two phases of power leads.

- 14 -

F st irst ar o jo t f f a gg ro ll, in m g.

Pay attention to the clog of strainer by checking the pressure change at suction side. The operation of SEALLESS PUMP, under normal use, is so quiet and vibrations so low little that it can hardly be judged whether the pump is operating or not. When operating the pump, check the following points.

(a) Check that the flow rate and discharge pressure are correct as specified. (b) Check for any abnormal noise. Note: When pump suction is under vacuum, open the discharge valve partly and leave it for 15 min. (c) Check the pump for cavitations conditions. When opening the discharge valve gradually, the abnormal sound and vibration will occur in the pump, and the flow rate will not increase even if the discharge valve is opened further; this is known as CAVITATION. Note: Never operate the SEALLESS PUMP under the condition of cavitations. (d) Check that the electric current of the motor is under the rated value. SEALLESS PUMP motor is selected so as not to be overloaded against the specifications required. If the flow rate exceeds the specified value, the pump may be overloaded. Then, reduce the flow rate and adjust the current within the rated current value. (e) Ensure that cooling line of motor, is working correctly. Check the difference of temperature at the out let and inlet. When operating the heating medium pump at a ambient temperature with high viscosity, reduce the discharge valve opening and adjust the current within the rated current value until the temperature reaches to the specified level. When abnormal condition occurs, stop the pump operation immediately and follow the troubleshooting chart.

3. Routine Inspection during operation

:-

The following items should be checked on a routine schedule to verify pump operation. Check discharge pressure against original design specification. Check ammeter readings compared to initial readings start up readings. Check for abnormal noise and any increase in vibration levels. Check the bearing monitor to ensure that it is in the safe operating range and not in the red zone. Check the cooling water in and out line for a temperature differential.

- 15 -

4. Procedure to Stop :-

The Fig. is self explanatory which describes the procedure to stop the pump.

Fig. 14: Procedure to stop

5. Starting after extended period of non-use :When the pump is started after extended period of non use check motor insulation and Winding resistance of the motor. Then start the pump by initial starting procedure.

Fig. 15: Start after non-use

- 16 -

6. Minimum Flow Rate:Flow rates vary, depending on the type of pump, NPSH available and fluid characteristics shown on the specification data sheet. The flow rate specified is a minimum value and the pump should always run above this rate. If the operating flow rate required by the customer is less than the minimum flow rate of the pump, it will be necessary to make by-pass line that will be able to recycle the balance flow to the suction vessel. Do not return the balance flow to the suction pipe directly.

Suction tank Discharge side valve By-pass piping Liquid By pass flow control valve or orifice Pressure gauge

SEALLESS

Fig. 16: Example of By-Pass Passing

- 17 -

III. Maintenance
1. Daily Check
Check if the pointer of the bearing monitor is in the white zone. If the pointer is in the red zone disassemble and check the bearing wear. In continuous operation check out the following time to time during continuous operations, check the following items at least once a day. Pump differential pressure, flow, and ampere drawn should be near specification sheet values Condition of the suction strainer should be verified to assure that NPSH not being reduced. Abnormal sounds or vibrations? Check temperature of pump components. Whether cooling water is flowing normally Whether there is any leakage from gasket, O ring packing, and Circulation tube, etc.

Fig. 17: Daily Check

- 18 -

2. PERIODICAL CHECKS :Carry out periodical checks at least once a year. Items to be checked: a) Check the wear condition of bearing, shaft sleeve, and Thrust washer; compare these with the permissible wear value shown in Table-4. if the wear exceed limit or estimated to exceed on further operation period replace them with new ones. b) Check rotor and stator contact. If there is any damage, replace it with new one. c) Check impeller and casing contact. If the clearance of fixed orifices shown in Fig.-1 exceeds 0.5 mm on radius, replace them with new ones.
One year
Annual check

Fig. 18: Periodical Check

0.5mm on radius

0.5mm on radius

FIG. - 1

Fig. 19: Clearance of fixed orifice d) e) f) g) h) i) j) Check whether lock washer for impeller bolts, liner disc bolts, etc. are loose. Check scale deposit in stator jacket. Disassemble and clean if scale is adhering. Check and clean filter mounted on pump discharge nozzle for circulation Check pump suction side strainer and clean it. Change used lock washers with new ones. Check and bend the tongue of washers firmly for preventing looseness. Check deflection of rotor shaft. If deflection exceeds 0.1 mm, repair or replace it with new one. Check corrosion and/or erosion condition.

- 19 -

Checking of Bearing:In case of SEALLESS PUMP, bearing wear beyond its limit cause contact of the rotor sleeve and stator liner and result in serious damage of motor finally. Pay attention to check bearing monitor. Periodical checks are essential for bearing maintenance. The same sized bearing is adopted at front and rear side of pump. 1) Life of Bearing Since bearings are used in the liquid, its life depends on the characteristic, temperature, Etc. of the liquid. Usually, the bearings are durable enough for more than one year (Approx. 8,500 Hours) of continuous operation in liquid equivalent to water. Check the wearing condition of the bearings after a year or 8,500 hours operation and Estimate the life under the individual condition. Dont fail to check the bearing after disassembling pump when a strange sound or Vibration is found during operation, and when periodical check of pump is made limit of bearing wear is shown in Table as follows, and according to this table, replace the worn out bearings with new ones. Maximum Value of Bearing Inside Dia. D (mm) 28.4 34.5 41.5 54.5 80.4

Motor Size (kW) 0.75 - 2.2 2.6 5.5 7.5 - 15 18.5 - 50 ABOVE 50

Minimum Value of overall Length L (mm) 39.5 59.5 79.5 105 109.5

TABLE 4: BEARING WEAR LIMIT


THRUST WASHER BEARING

SHAFT

SLEEVE

Fig. 20: Bearing wear limit

main impeller starts to contact the liner disc before reaching to L size on the Table above. When replacing bearing, check also shaft sleeves and thrust washers. When there is any damage on the surface of shaft sleeve and thrust washer, replace them, too.

Note: When the thrust supporting surface of the bearing on the rear side, the

- 20 -

IV. SAFETY FEATURES


1. Bearing Monitor (Mechanical) :When a bearing monitor is delivered separately, a dummy plug is inserted in the hole for bearing monitor on rear bearing housing. Remove the dummy plug, then install the bearing monitor to pump before operation.

Mounting Method of Bearing Monitor


Remove dummy plug A. After inserting the tip of sensor in to an eccentric hole of end nut (40) while slanting bearing monitor (29), place it on RB housing (21) in the correct position and fit the monitor in socket portion of RB housing, and after that, mount the monitor straightly at the centre of the pump and tighten nut (28), where mounting of monitor is completed.

21

RB HOUSING DUMMY PLUG A

29 BEARING MONITOR

Fig. 21: Mounting of Bearing Monitor

Function of Bearing Monitor:The Bearing Monitor signals that the bearing wear is close to breaking point allowing for bearings to be replaced in time, thus preventing excessive damage. The monitor is a gauge filled with gas and mounted on the rear bearing housing. The probe or the bearing monitor is inserted into the end nut of the shaft. When the bearing wear exceeds the set limit the probe strikes against the end nut and breaks realizing the gas and reducing the pressure in the monitor, indicating an abnormal state on the indicator. The monitor which indicates the red zone cannot be used again as shown in fig.24. Use a new one.

- 21 -

2. E - MONITOR : If the bearing is worn, causing the rotor to rotate off-center or shifted axially, a voltage proportional to the eccentricity or degree of wear is produced at the sensor embedded in the stator. The voltage produced indicates the conditions of bearing wear on the Emonitor LED display section. It also indicates reverse rotation as well.

Fig. 22: Principle of operation of E-Monitor

An E-MONITOR display section is mounted on the terminal box of the pump main unit. The pump main unit and E-MONITOR display section are supplied with wiring already connected.

HYDRODYNE

HYDRODYNE Fig. 25: Various Zones of E-Monitor

HYDRODYNE

electronic

electronic

electronic

Fig. 23: Various Zones of E-Monitor

- 22 -

Various Zones of E-Monitor: Green: - The LED of this zone indicates normal or good condition of the bearing. Yellow: - When the LED of this zone blinks it indicates that the bearing has begun to wear out and its the time for replacement. Red: It indicates the bearing has weared out and the pump has to be stopped to prevent other working parts of the pump from being damaged. Power: - It indicates that the pump is running. Reverse: - It indicates the reverse direction of rotation of the pump.

3. DRY RUN PROTECTION :It is a low current sensing device, to protect the pump from cavitations condition when the suction flow drops to unsafe levels. This protective device automatically trips off the pump avoiding any damages. In other words the device prevents dry run of the pump. The fall in the suction flow may be due to following reasons:Choking of the strainer. Unforeseen closure of the suction and discharge valve. Suction flow affected by vapor lock and available NPSH at any point of time. This instrument consists of two parts i.e.: Current converter, Current sensor. The instrument is connected in the circuit as indicated in the circuit Diagram a) CURRENT CONVERTOR: Run all three leads connecting motor to starter in the same direction. Number of turns depends on rated current for which under current trip is to be provided. Wires can be run through any hole and there is no correspondence between these holes, and the three wires.

Fig. 24: Wiring Turns to Current Converter

- 23 -

Current sensor Rated Current Current Scale (current multiplying setting range) factor decal (A) No. 1 to 2.5 0.25 2 to 5 0.5 4 to 10 1 8 to 20 2 16 to 40 4 32 to 80 8 64 to 160 16

Current Converter Numbers of Conductor Setting Tap Type runs through holes. 8 20 4 20 2 20 SET 3A 1 20 1 40 1 80 1 Fixed SET 3B

Determine the number of primary conductor runs through the holes and Setting tap from Table 6 above.

EXAMPLE For a Dry Run Protection to be provided for a motor trip below 4Amps. Motor current, the current setting range should be 2 5 A, the Number of runs through the holes is 4 and setting tap is 20. The Current scale multiplying factor is 0.5. In the tap setting, insert a setting Screw into the required tap hole with a screw driver. After setting, be sure to replace the cover. b) CURRENT SENSOR : Current sensor front and rear view are shown in the enclosed drawing. Leads 1,2,3,4,5,6,7 & 8 of the current sensor are connected in the Manner as shown in the circuit diagram of Dry Run Protection . Start the pump with liquid and note the SHUTT OFF current. The DRP should than be set to 0.5 AMP. Reading below SHUTT OFF current.

4. THERMOWELL :Thermowell/thermocouples are installed in the construction for measurement of fluid temperature. This enables switching off the pump assembly if the temperature crosses acceptable limits, preventing excessive damage to the pump.

- 24 -

V. ASSEMBLY AND DISASSEMBLY


DISASSEMBLY METHOD:The disassembly method is given below, The part numbers in the text correspond to the part numbers in the assembly sectional views in Fig.1-1 Before starting assembly, completely drain all liquid from the pump if appropriate for the liquid being handled, rinse the pump interior. Failure to do so with certain liquids may result in injury to the eyes or other injuries. When removing the entire pump, the procedures given in (1), (2) and (3) of this section will allow you to remove the entire pump, except the base. When disassembling the pump for an internal check, carry out the procedures given in (1), (4), and (5) of this section. Make sure that power to the motor is OFF before removing electrical wiring From the motor. Failure to do so may Result in electric shock. 1) To remove leads for the power and Thermostat, use a temporary fixing pin for inverting so that the terminal section of the terminal assembly. 2) Affix labels such as U, V, W, T1 and T2 to the leads to be removed. After affixing the labels, remove the motor wires Remove the piping at the pump suction/discharge.

T2

T1

U V

Fig. 25: Labelling for electrical wiring

- 25 -

3) Remove the pump and base In the case of the H (horizontal) type, remove the connection bolt [122A] between the stand [36] and base [37]. (Refer to Figure as follows).

Stand

Base
Fig. 26: Removing pump from base 4) Remove the pump casing fixing bolt [112] lets you pull out the backward while the casing [12 ] remains the pump suction/discharge piping.( Refer to Figure)

Fig. 27: Removing pump casing from motor Disassemble of the pump up to this point allows you to check the casing interior and impeller [11]. Proceed with disassembly to check the bearing [22] inside the rotor [16] chambers, as follows: 5) Removing the impeller (refer to figure) Unfold the impeller bolt (108), Washer assembly attached to the end of the shaft (15), and remove the impeller bolt (108). This allows you to pull out the impeller (11).

Fig. 28: Removing the impeller

- 26 -

When pulling out the impeller, avoid the bending the shaft, and take care to avoid misplacing the impeller bolt, washer assembly; instead, replace with a new one. 6) Removing RB housing (refer to fig. 4-6) Remove the fixing bolt (105) of the RB housing (21) and pull it out backward.

Fig. 29: Removing R.B.H & Mechanical Bearing Monitor 7) Removing the mechanical bearing monitor (refer to figure) Loosen the nut (28), tilt the bearing monitor, and pull out backward.

Fig. 30: Removing bearing monitor

8) Removing liner disc and adapter Remove the nut (102), then remove the adapter (13) and liner disc (52) together. The adapter and liner disc are integrated together as a one piece unit. The O ring (33) comes off with these units. 9) Removing FB housing Remove the spacer (25) from the rotor assembly (16) and pull out the auxiliary impeller (11). Then remove the FB housing (20).

Fig. 31: Pulling out rotor assembly

- 27 -

10) Pulling out the rotor assembly (refer to figure) Disassembly up to this point will allow you to pull out the rotor assembly (16) gently pull out the rotor assembly. Pull straight back, without applying excessive force.

Fig. 32: Removing End - Nut 11) When removing the bearing sleeve (23), loosen the end nut (40) at the back of the shaft (15). Since this end nut is threaded with a left-handed thread, turn clockwise to loosen. (Refer to figure)

ASSEMBLY METHOD:Assembly can be performed in the reverse order of disassembly. However, keep in mind the following points. 1) When replacing the bearing (22), insert the seat into the notch on the circumference of the bearing before introducing it into bearing housing. Then insert the bearing into bearing housing and holt in place until the fixing screw contacts the seat to the extent that the bearing slightly moves to the right and left. (Refer to figure)

Fig. 33: Inserting the Bearing in housing

- 28 -

2) When replacing the thrust washer [24]. Fit the washer so that the plate surface will face outside. The bearing [22] will wear out prematurely unless the lustrous plated surface face in the direction shown in Figure Fir the bearing sleeve [23].(The above applies for hard chrome-plated items.)
14

Key

23

Shaft sleeve

24

Thrust washer

Plated part

Plated part

Fig. 34: Orientation of Thrust Washer

3) Attach the key, auxiliary impeller [46], and spacer .Make sure that the blade side of the impeller faces the stator assembly. 4) When attaching the RB housing [21] and adapter [13], do not forget the O ring. Also be sure to firmly and evenly tighten the bolt [102]. 5) When mounting the impeller [11], make sure there is no backlash in the key [14].

Fig. 36: Fixing Impeller

- 29 -

6) Securely tighten the impeller bolt [108] or inducer with the torque. Tightening the impeller simply by holding with one hand will be insufficient. Try to tighten the impeller bolt while inserting a lever (Refer to Figure). After tightening the impeller bolt, correctly fold the washer of the washer assembly along one side of the hexagonal-head bolt. Refer to Figure). When the impeller has been mounted, turn the impeller by hand to determine if it turns smoothly before attaching the casing. If it is not possible to turn the impeller by hand, disassemble it once again and confirm that the FB housing and RB housing are correctly mounted and that the shaft is not bent

Fig. 37: Folding the impeller washer

7) To avoid uneven tightening of the casing fixing bolts [111], tighten the bolts evenly, in the sequence of opposing bolt Shown in Figure

Fig. 38: Bolt tightening sequence

- 30 -

- 31 -

VI. TROUBLE SHOOTING CHART

- 32 -

HYDRODYNE CANNED MOTOR PUMP TYPE HD BASIC PUMP INSTRUCTION MANUAL NO PART OF THIS PUBLICATION MAY BE REPRODUCED OR MODIFIED OR TRANSMITTED IN ANY FORM OR BY ANY MEANS WITHOUT PRIOR CONSENT FROM HYDRODYNE INDIA PVT. LTD.

MANUAL NO. : HD-2010 REVISED EDITION: - June 7, 2010 PUBLISHER: HYDRODYNE (INDIA) PVT. LTD. B-47, PARAMOUNT, NEW LINK ROAD, ANDHERI (W) MUMBAI-400053