TANK SUPPORT
Values from frame analysis for water test greatest moment 24" piling, 42" Deck, 48" Pile Cap ENGINEERING with the SPREADSHEET Copyright 2006 American Society of Civil Engineers
A B C D E F G H I J
Page 53 - 1
53
K L M
Christy 3:16
03/13/14
216516739.xls.ms_office
N
CONCRETE BEAM DESIGN fy 60 ksi f'c 4 ksi d' 5 in bw d depth_OA 84 in 40.0 in 42 in Bar Qty Bar Size# 22.00 7 22.00 7 936.0 k-ft 1341.0 k-ft ult
I gross 575,967 in^4 / I cracked 123,858 in^4 / I effective 575,967 in^4 yield strength of reinforcing compessive strength of concrete depth of compression reinforcing width depth of tension reinforcing overall depth As 13.20 in2 13.20 in2 required service level moment required ultimate/factored moment
90
80 70 60 50
40 30 20 10 0
0 20 40 60 80
row 20
MU prov 2964.67 k-ft ultimate provided OK Beam stressed to 45 % OK As min 11.20 < As provided 13.20 OK x balance 14.87 4.264 required
100
Figure 53-1 Beam cross-section with Whitney's stress block and reinforcing. row 30 Bar Size # in American nomenclature, bar size is given as a number which equates to 8 th's of an inch hence, a #6 bar is 6/8 inch = 3/4" fy f'c ultimate tensile strength of reinforcing, k/in ultimate compression strength of concrete, k/in2
2
Length t c flange
39 4.5 78 0
ft in in logic
Ig I cracked Ie t
in in4 4 in unitless
min -- Minimum Reinforcement in Flexural Members As min 1 3 f'C /fy bw d 02 ACI 10.5.1 (10-3) 10.63 in2 3 * 4 *1000 * 84.0 * 40.0 /60 /1000 As min 2 11.20 in2 200 * w * d /fy /1000 02 ACI 10.5.1 200 * 84.0 * 40.0 /60 /1000 MAX(11.20, 10.63) 13.20
As logic
1 logic
When the area of tension reinforcing steel is less than +As minimum, the amount of reinforcing provided must be increased by 1/3 beyond that needed for tensile reinforcement. 02 ACI 10.5.3 When the beam is stressed to 75% and +As = 1.33 x As provided, the minimum requirements of reinforcement have been met. For Seismic Resistance As min 11.20 in2
row 60 negative reinforcing - usually the top steel, in2 positive reinforcing - usually the bottom steel, in2
row 70
Page 53 - 2
53
K L M
Christy 3:16
03/13/14
216516739.xls.ms_office
N
PHOTOGRAPHS
row 90
Splicing
Splicing adds to the congestion. 1" spacing is generally required to allow the 3/4" aggregate to pass down through the upper and lower mats. This mat is made up of #7's @ 4" each way. Because the cross-section of reinforcing bar is oblong and with lugs, about 1" to 1 1/8" of space is required to accomodate the bar.
1 1/2" 2"
Figure 53-4 #7's @ 4." For some serious reinforcing, try #8's @ 4."
The contractor did specify a specialized mix to make sure that the concrete would place easily.