A. CIRCUIT BREAKERS Sl. No.

1 2 3 4 5 6 7 8 9 10 11 a) b) Description Manufacturers Name and Country Manufacturers type designation Applicable Technical Standards (a) Type of circuit breaker (b) Type of tank (live/dead) Rated frequency Number of poles Whether 3 pole or single pole unit No. of breaks per pole Type -Outdoor Rated continuous current at design temperature of 38 deg. C Rated short circuit breaking current RMS value of AC component Percentage DC component Unit Guaranteed Particulars 132 kV 33 kV

(Hz) (Nos.)

(Amp)

(kA) (%) (kA) (Yes/No) (kA)

c) Asymmetrical breaking current at highest system voltage d) Is it possible to increase the rupturing capacity at a later date 12 Short time current rating for 1 sec. 13 Rated operating duty cycle 14 Rated short circuit making current 15 First pole to clear factor 16 Rated characteristics for short time faults and rated breaking capacity

(kA peak) (kA peak)

(kA) 17 Rated line charging breaking current with temporary over voltage upto 1.4 p.u. (kA, kV) 18 Rated out of phase breaking current and corresponding transient recovery voltage 19 Rated small inductive breaking current (Amp, p.u) with corresponding switching over voltage

-1Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars 132 kV 33 kV

20 Rated cable charging breaking current (Amp, p.u) and corresponding over voltages recorded during test 21 (a) Maximum period between first contact and last contact in a pole (b) Maximum pole descrepancy 22 Rated (single) capacitor bank breaking current and corresponding over voltages recorded during test 23 Data on re-striking voltage for terminal faults a) Amplitude factor 100% capacity 60% capacity 30% capacity 10% capacity b) Phase factor 100% capacity 60% capacity 30% capacity 10% capacity c) Rate of rise of re-striking voltage 100% capacity 60% capacity 30% capacity 10% capacity d) Transient recovery voltage 100% capacity 60% capacity 30% capacity 10% capacity 24 a) Is circuit breaker re-strike free under all conditions of operation. b) Means adopted if any to check the voltage rise 25 Max. arcing time under any duty condition with limiting conditions of voltage and pressure
(Amp, p.u)

(kV peak) (kV peak) (kV peak) (kV peak) (Yes/No)

(ms)

-2Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars 132 kV 33 kV

(ms) 26 Maximum total break time under any duty condition for any current up to rated breaking current with limiting conditions of voltage and pressure (ms) 27 Maximum closing time (ms) 28 Minimum opening time under any duty condition with limiting voltage and pressure (ms) 29 Maximum close open time under any condition with limiting voltage and pressure (ms) 30 Minimum re-closing time at rated interrupting capacity from instant of trip coil energisation 31 Minimum dead time for (ms) a) Three phase reclosing (ms) b) Single phase reclosing (ms) c) Limits of adjustment of dead time for three phase reclosing 32 Difference in the instants of closing opening of contacts at rated voltage and pressure (ms) a) Within a pole (ms) b) Between poles 33 Type of device, if any, used to obtain uniform voltage distribution between contacts 34 Maximum temperature rise for (Deg.C) a) Main contacts over ambient temperature at site (Deg.C) b) Terminals to be connected to the external conductor 35 One minute power frequency withstand test voltage for complete (kV rms) a) Between line terminal and ground objects with circuit breaker contacts closed (kV rms) b) Between terminals with breaker contacts open 36 1.2/50 microsecond lightning impulse withstand test voltage for complete circuit breaker a) Between line terminal and ground with (kV peak) circuit breaker contacts closed

-3Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars 132 kV 33 kV

b) Across terminals with circuit breaker contacts open - one terminal lightning impulse - opposite terminal power frequency 37 Corona extinction voltage 38 i) Radio Interference Voltage at a) 0.5 MHz b) 1.0 MHz c) 1.5 MHz d) 2.0 MHz ii) Partial discharge level Whether the circuit breaker is fixed trip or trip free a) Rated voltage of closing coils b) Range of pick up value a) Rated voltage of tripping coil b) Range of pick up value Normal power consumption at rated voltage for Trip coil Closing coil Number of trip coils Type of main contact Whether arcing contact provided Material of Main contact Arcing contact Whether contacts silver plated Minimum thickness of silver plating Contact pressure of main contact Number of auxiliary contacts per pole provided for Purchasers use. NO NC Rated voltage of auxiliary contacts Current capacity of auxiliary contacts Continuous Breaking Whether auxiliary contacts silver plated SF6 circuit breakers

(kV peak) (kV peak) (kV rms) (mV) (mV) (mV) (mV) (mC) Yes/No (Volts) (Volts) (Volts) (Volts)

39 40 41 42 a) b) 43 44 45 46 a) b) c) d) e) 47 a) b) 48 49 a) b) 50 51

(Watts) (Watts) (Nos.) (Yes/No)

(Yes/No) (mm) (kg/sq. cm)

(Nos.) (Nos.) (Volts) (Amp) (Amp) (Yes/No)

-4Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description (a) Quantity of SF6 gas required for each pole of circuit breaker (b) Guaranteed maximum leakage rate of SF6 gas per year (c) Rated pressure of SF6 in opeerating chamber (d) SF6 density monitor provided (e) Limits of pressure of SF6 gas at which breaker operate correctly Number of operations after which SF6 gas replacement is necessary At full rupturing capacity At 50% of rated rupturing capacity At 10% of rated rupturing capacity At rated current Number of operations after which main and auxiliary contacts replacement is necessary. At full rupturing capacity At 50% of rated rupturing capacity At 10% of rated rupturing capacity At rated current Number of operations at rated current after which routine inspection / maintenance of breaker is necessary. Number of operations at full rupturing capacity after which routine inspection/maintenance of circuit breaker is necessary. Parameters of SF6 gas required for initial filling and satisfactory operation Density Dielectric strength

Unit
(kg) (%) (kg/sq. cm) (Yes/No) (kg/sq. cm)

Guaranteed Particulars 132 kV 33 kV

52 a) b) c) d) 53

(Nos.) (Nos.) (Nos.) (Nos.)

a) b) c) d) 54

(Nos.) (Nos.) (Nos.) (Nos.) (Nos.)

55

(Nos.)

56 a) b)

(kg/sq. cm) (kV/mm) (ppm) (ppm) (ppm) (Deg. C) (Ohm-m)

c) Acidity d) Water content e) Oil content f) Condensation temperature g) 57 a) b) c) Resistivity Support insulators column/units Make and type Numbers per pole Weight -5Section - IX : Guaranteed & other Technical Particulars

(Nos.) (Kg)

Sl. No.

Description

Unit
(mm x mm x mm) (kV rms) (kV peak) (kV rms) (mm) (Kg) (kV)

Guaranteed Particulars 132 kV 33 kV

d) Transport dimensions e) One minute power frequency withstand voltage f) Lightning impulse withstand voltage g) Corona extinction voltage h) Creepage distance i) Permissible safe cantilever strength j) Insulation class k) Flash over voltage 58 Type of operating mechanism for a) Closing b) Opening

(kg/sq. cm) 59 Rated pressure and limits of pressure of operating mechanism in case of pneumatic and hydraulic mechanism 60 Pneumatic operating mechanism (kg/sq. cm) a) Rated operating pressure b) Range of pressure for (kg/sq. cm) i) Closing (kg/sq. cm) ii) Opening c) Air consumption at rated pressure for (m3) i) Closing (m3) ii) Opening (m3) iii) Close - Open (m3) d) Number and capacity of local air receiver (minutes) e) Time required for filling the air receiver to its rated pressure from atmospheric pressure (kg/cm2 ) f) Design pressure of air receiver (Nos.) g) Number of closing opening operations possible without charging the air receiver h) Arrangement provided for preventing the operation of breaker with insufficient air pressure i) Compressor i) Make and type (Nos.) ii) Number of compression stages (kg/sq. cm ) iii) Compression pressure

-6Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit
(Yes/No)

Guaranteed Particulars 132 kV 33 kV

iv) Whether compressor is provided with its own filter. If so give type and make v) Effectively delivered air in liters per hr. at atmospheric pressure. j) Compressed air piping i) Material ii) Inner & outer diameter

(Ltr/hr)

(mm, mm)

61 a) b) c) d) e)

62 a) b) c) d) e)

f) g) 63 a) b)

(kg/sq. cm ) iii) Working pressure Spring charged mechanism Name of Manufacturer (Volts) Rating of motor (Sec) Time required for charging the closing spring (Nos.) Number of CO operation possible after failure of auxiliary supply Whether indication for spring charged (Yes/No) condition provided in central control cabinet. Hydraulic operating mechanism (kg/sq. cm ) Rated pressure of oil in operating cylinder (kg/sq. cm ) Limits of operating pressure (litres) Specification of oil and quantity required per breaker (Nos.) Number of CO operation possible after loss of hydraulic pressure. Details of arrangement to prevent change of position of breaker in the event of loss of hydraulic pressure. Details of motoring arrangement for hydraulic pressure Details of hand pump set provided for emergency operation Control cabinet Manufacturers Name (mm) Thickness of sheet steel

c) Degree of protection provided d) Colour of finish paint i) Outside

-7Section - IX : Guaranteed & other Technical Particulars

Sl. No. ii) Inside

Description

Unit

Guaranteed Particulars 132 kV 33 kV

e) Control wiring i) Rated voltage ii) Size f) Terminal Block i) Make ii) Current rating 64 Terminal clamps and connector a) Manufacturers Name b) Applicable standard c) Material i) Clamp body ii) Bolts and nuts iii) Spring washer iv) Liner if any d) Rated current e) i) Rated terminal load ii) Factor of Safety f) Radio interference voltage g) Corona extinction voltage h) Maximum allowable span for aluminum tube of 114.2 mm outer diameter and 97.18 mm inside diameter on equipment terminal pad with rated fault current and 7 m and 4.5 m, phase to phase spacing . 65 Over all dimensions a) Height b) Width c) Length 66 Clearances a) Between poles b) Between live part and earth 67 Weight of a) Each pole b) Complete Breaker for foundation design 69 Impact loading on foundation design 70 Noise level a) At base b) At 50 m distance from base

(Volts) (Sq. mm)

(Amp)

(Amp) (Kg or N)

(mV) (kV rms) (m)

(mm) (mm) (mm) (mm) (mm) (Kg) (Kg)

(dB) (dB)

-8Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars 132 kV 33 kV

71 Seismic level for which breaker is designed 72 Compliance to technical specification w.r.t. parameters specified for (a) Control cabinet (b) Bushing/support insulator (c) Terminal connector (d) SF6 Gas 72 Enclosures Whether the following are enclosed: i) Type test reports for main equipment and auxiliaries ii) Drawings as per specification iii) Technical literature for circuit breaker, SF6 gas, support insulators and operating mechanism

Yes/No Yes/No Yes/No Yes/No

(Yes/No) (Yes/No) (Yes/No)

-9Section - IX : Guaranteed & other Technical Particulars

B. Sl. No. 1 2 3 4 5 6 7

ISOLATORS / DISCONNECTORS AND EARTHING SWITCHES (145 & 36 kV) Description Manufacturers Name and Address Type Designation Applicable standard
(kV) (Hz) (Nos.) (Yes/No) Unit

Guaranteed Particulars
3 /2/1 Pole

Rated voltage Rated frequency No. of Poles Whether all three poles are ganged together mechanically/electrically 8 Rated normal current a) Under site conditions b) Under normal conditions as per 9 IS/IEC Rated short time withstand current for 1 Sec. 10 Rated peak short circuit current of a) Isolator b) Earthing switch 11 Rated short circuit making current for isolator only 12 Rated magnetizing current and capacitive current make and break 13 capacity Temperature rise over ambient temperature at site corresponding to a) Maximum continuous current b) Short time current 14 Rated Insulation levels a) 1.2/50 microsecond lightning impulse withstand voltage i) to earth i) across the open isolator - one terminal lightning impulse - opposite terminal power frequency b) 1 minute power frequency withstand voltage i) to earth ii) across the terminal of open isolator 15 Corona extinction voltage 16 Radio Interference Voltage at 1.0 MHz at 105 kV rms for 132 kV system.

(Amp) (Amp) (kA rms)

(kA peak) (kA peak) (kA)

(Amp)

(Deg. C) (Deg. C)

(kV peak) (kV peak) (kV peak)

(kV rms) (kV rms) (kV rms) (mV)

-16Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars
3 /2/1 Pole

17 Rated mechanical terminal loads for horizontal break isolator a) Longitudinal b) Transverse 18 Total operating time of Isolator & earth switch a) Opening time b) Closing time 20 Dielectric withstand capacity of completely assembled isolator/earth switch 21 Main contacts (fixed and moving) a) Type b) c) d) e) f) g) Material Whether contacts are silver plated Thickness of silver coating Contact area Contact pressure Max. Current density under normal current carrying capacity

(N) (N)

(Sec) (Sec)

(Yes/No) (Microns) (Sq. mm) (kg/sq. cm) (A/sq. cm) (Nos.)

h) Number of operations which the isolator can make without deterioration of contacts. 22 Auxiliary contacts a) Isolator i) Total number of spare contacts provided for purchasers use a) NO b) NC ii) Rated voltage iii) Rated continuous current iv) Rated breaking current b) Earth Switch i) Total number of spare contacts provided for Purchasers use a) NO b) NC ii) Rated voltage iii) Rated continuous current iv) Rated breaking current c) Whether arcing contacts provided and if so give type and material used. 23 Insulators

(Nos.) (Nos.) (Volts) (Amp) (Amp)

(Nos.) (Nos.) (Volts) (Amp) (Amp) (Yes/No)

-17Section - IX : Guaranteed & other Technical Particulars

Sl. No. a) Make

Description

Unit

Guaranteed Particulars
3 /2/1 Pole

b) Type (solid core) c) Applicable Standard d) Number of insulator stacks per pole e) Number of insulators per stack f) 1 minute power frequency withstand voltage g) Lightning impulse withstand voltage h) Visible corona extinction voltage i) Creepage distance j) Weight of each post insulator per stack k) Tensile strength l) Compressive strength m) Torsional strength n) Cantilever strength o) Bolt circle dia 24 Minimum phase to phase clearance 25 a) Minimum phase to ground clearance b) Minimum distance between phases when isolator is open 26 Types of bearings 27 Locations of bearings 28 Type of lubricant for bearings 29 Terminal Clamps & Connectors a) Manufacturers name b) Applicable standard c) Material i) Clamp body ii) Bolts and nuts iii) Spring washer iv) Liners if any d) Rated current e) Rated terminal load f) g) h) i) Weight of clamp complete with hardware Radio Interference Voltage Corona extinction voltage Maximum allowable span for aluminum tube with applicable size with rated fault current and applicable phase to phase spacing for Operating Mechanism Type of operating mechanism Name of manufacturer
(Nos.) (Nos.) (kV rms) (kV peak) (kV rms) (mm) (Kg) (Kg) (Kg) (Kg-m) (Kg) (mm) (mm) (mm) (mm)

(Amp) (Kg) (Kg) (mV) (kV rms) (m)

30 a) b)

-18Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit (Yes/No)

Guaranteed Particulars
3 /2/1 Pole

c) Whether inter-pole cabling included in scope of supply (Yes/No) d) Whether separate operating mechanism provided for operation of isolator pole and earthing switch. e) Electrical operation (AC/DC) i) Motor type ii) Applicable standard (V, A) iii) Rated voltage and current iv) Type of enclosure and method of cooling (Watts) v) Power required for closing and opening operation (Sec) vi) Running time of motor for closing and opening operation (Volts) vii) Control supply for motor control center f) Type of manual operating mechanism for isolator pole (Kg) g) Force required to operate manual operating mechanism (Yes/No) h) Whether padlocking included as per the specification i) Type of manual device for Earthing Switch (Kg) j) Force required to operate manual device for earthing switch 31 Interlocking (Yes/No) a) Details of mechanical interlock between isolator and earth switch (Yes/No) b) Details of electrical interlock for isolator and earth switch enclosed (Yes/No) c) Details of electrical interlock provided to satisfy relevant clause of Section-Major Substation Equipment. d) Details of electrical scheme to provide (Yes/No) remote alarm for pole discrepancy. e) Details of electrical interlock to bring (Yes/No) back all three poles to open position in case any pole fails to close within specified time f) Details of provisions to cut off supply (Yes/No) to the motor during manual operation and provision for declutching the

-19Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit (Yes/No)

Guaranteed Particulars
3 /2/1 Pole

g) Arrangement provided to prevent electrical or manual operation unless interlock conditions are satisfied. 32 Control Cabinets / Marshalling box a) Manufacturers name b) Thickness of sheet c) Degree of protection provided d) Colour of finish paint i) Outside ii) Inside e) Control wiring i) Voltage rating ii) Size and material of conductor f) Terminal block i) Make ii) Current rating Space heater rating at 240 volts Whether all cabling for wiring out contacts to control cabinet included in scope of supply Size and Weight Weight of each pole

(mm)

(Volts) (Sq. mm / SWG)

(Amp) (Watts) (Yes/No)

g) h)

33 a)

(Kg) (mm) (mm)

b) Space requirement i.e. length. c) Height of 3 phase isolator without earth switch. d) Dimension of the isolators i) without earthing switch ii) with earth switch on one side

iii) with earth switch on both sides 34 Enclosures Whether the following are enclosed i) Type test report for main equipment and auxiliaries ii) Drawings as per specification iii) Technical literature for isolator, operating mechanism and support insulators. 35 Compliance to Technical Specification w.r.t. (a) MOM box (b) Support insulators

(mm x mm x mm) (mm x mm x mm) (mm x mm x mm)

(Yes/No) (Yes/No) (Yes/No)

Yes/No Yes/No

-20Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description (c) Terminal connectors

Unit Yes/No

Guaranteed Particulars
3 /2/1 Pole

36 A. a) b) c) B. a) b) c)

Tandem Pipe Size ( internal diameter) Class Material Down pipe Internal dia. Class Material

(mm)

(mm)

-21Section - IX : Guaranteed & other Technical Particulars

C. CURRENT TRANSFORMERS (145 kV & 36 kV) Sl. Description No. 1 Manufacturers Name and Address 2 Manufacturers type designation 3 Type of CT (Live or dead tank type) 4 5 6 7 8 a) b) c) d) e) f) g) h) i) j) k) l) a) b) c) d) e) f) g) h) i) Rated voltage Max. Continuous rated voltage Standards applicable Rated frequency Core Details - Core 1 Rated primary current Rated secondary current Rated output (Burden) Rated output at 0.8 lagging power Class of accuracy Accuracy limit factor Saturation factor Knee point voltage at different taps C.T. Resistance of secondary winding corrected to 70 Deg. C Magnetizing current at knee-point voltage Secondary limiting voltage Instrument Security Factor (ISF) Core Details - Core 2 Rated primary current Rated secondary current Rated output (Burden) Rated output at 0.8 lagging power factor Class of accuracy Accuracy limit factor Saturation factor Knee point voltage at different taps
Unit

Guaranteed Particulars

(kV) (kV) (Hz) (Amp) (Amp) (VA) (VA)

(Volts) (Ohms) (mA) (kV)

(Amp) (Amp) (VA) (VA)

(Volts) (Ohms) (mA) (kV)

C.T. Resistance of secondary winding corrected to 70 Deg. C j) Magnetizing current at knee-point k) voltage Secondary limiting voltage l) Instrument Security Factor (ISF) Core Details - Core 3 a) Rated primary current b) Rated secondary current c) Rated output (Burden) d) Rated output at 0.8 lagging power factor -33Section - IX : Guaranteed & other Technical Particulars

(Amp) (Amp) (VA) (VA)

Sl. No. e) f) g) h) i) j) k) l) a) b) c) d)

Description Class of accuracy Accuracy limit factor Saturation factor Knee point voltage at different taps C.T. Resistance of secondary winding corrected to 70 Deg. C Magnetizing current at knee-point voltage Secondary limiting voltage Instrument Security Factor (ISF) Core Details - Core 4 Rated primary current Rated secondary current Rated output (Burden) Rated output at 0.8 lagging power factor Class of accuracy

Unit

Guaranteed Particulars

(Volts) (Ohms) (mA) (kV)

(Amp) (Amp) (VA) (VA)

e) f) Accuracy limit factor g) Saturation factor h) Knee point voltage at different taps i)

(Volts) (Ohms) (mA) (kV)

C.T. Resistance of secondary winding corrected to 70 Deg. C j) Magnetizing current at knee-point k) voltage Secondary limiting voltage l) Instrument Security Factor (ISF) Core Details - Core 5 a) Rated primary current b) Rated secondary current c) Rated output (Burden) d) Rated output at 0.8 lagging power factor e) Class of accuracy f) Accuracy limit factor g) Saturation factor h) Knee point voltage at different taps C.T. Resistance of secondary winding corrected to 70 Deg. C j) Magnetizing current at knee-point k) voltage Secondary limiting voltage l) Instrument Security Factor (ISF) 9 One minute power frequency withstand test voltage of i) Primary winding ii) Secondary winding -34Section - IX : Guaranteed & other Technical Particulars

(Amp) (Amp) (VA) (VA)

(Volts) (Ohms) (mA) (kV)

i)

(kVrms ) (kV)

Sl. Description No. 10 1.2/50 microsecond lightning impulse wave withstand voltage of primary winding 11 One minute dry power frequency withstand voltage 12 Creepage distance 13 Rated continuous thermal current 14 Ratios available at different taps 15 16 17 18 19 20

Unit (kV peak)

Guaranteed Particulars

(kV rms) (mm) (Amp)

21 d) 24 25

(kA rms) Rated short time thermal current (Sec) Rated time for above (kA peak) Rated dynamic current for primary Class of insulation (Deg. C) Maximum temperature rise over ambient of 38 Deg. C at any part or oil (kV rms) a) Corona extinction voltage (mV) b) Radio Interference Voltage at 1 (pC) c) Partial discharge level (Kg) Total weight Standard to which oil conforms (litres) Quantity of oil (mm x mm Overall dimensions x mm) (mm) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

26 Heights of supporting structure 27 Drawings enclosed i) Magnetization curve ii) Ratio and phase angle characteristics at least up to accuracy limit factor iii) Ratio Correction Factor curve iv) Limits of composite error at rated primary saturation current (for protection core) v) Base plan vi) Maximum safe loading as per drawing vii) Foundation plan showing details of foundation bolts viii) Foundation loading ix) Support structure 28 Temperature Rise after passing short time Thermal current for one second 29 Current density in primary winding a) Normal rating at different taps b) Short time rating of 1 sec c) Dynamic rating 30 Type of primary winding 31 Number of primary turns -35Section - IX : Guaranteed & other Technical Particulars

(Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Deg. C)

(A/ sq. m) (A/ sq. m) (A/ sq. m)

(Nos.)

Sl. Description No. 32 Number of secondary turns 33 Flux density at knee point voltage (knee point defined at the point at which 10% increase in voltage produces a 50% increase in 34 Radio interference voltage a) With terminal connector mounted b) Under test condition 35 Variation in ratio and phase angle error due to variation in a) Voltage by 1% b) Frequency by 1 Hz 36 Source/grade of oil and standard with which it complies 37 Whether pressure relief device is provided 38 Mounting details 39 Whether the following are enclosed with tender: a) All type test reports b) Drawings as per the specification c) Technical literature for current transformer and marshalling box. 40 Weight of CT with oil

Unit (Nos.) (Tesla)

Guaranteed Particulars

(mV) (mV)

(%, %) (%, %)

(Yes/No) (Yes/No)

(Yes/No) (Yes/No) (Yes/No) (Kg)

-36Section - IX : Guaranteed & other Technical Particulars

D. POTENTIAL TRANSFORMERS (145 kV and 36 kV) Sl. No. 1 2 3 4 a) b) 5 6 7 8 9 10 11 12 a) b) c) d) 13 a) b) c) d) 14 a) b) c) d) 15 Description Manufacturers Name and address Manufacturers type designation Applicable standard Rated voltage Nominal Maximum Rated frequency Number of secondary windings No. of phases Maximum temperature rise over ambient of 38 Deg.C Reference range of frequency Reference range of temperature Rated primary burden Winding details - Windings 1 Rated primary voltage Rated secondary voltage Rated secondary burden Accuracy class Winding details - Windings 2 Rated primary voltage Rated secondary voltage Rated secondary burden Accuracy class Winding details - Windings 3 Rated primary voltage Rated secondary voltage Rated secondary burden Accuracy class Rated voltage factor and corresponding rated time Unit Guaranteed Particulars

(KV rms) (KV rms) (Hz) (Nos. ) (Nos.) (Deg. C) (Hz) (Deg. C) (VA) (kV) (V) (VA)

(kV) (V) (VA)

(kV) (V) (VA)

16 Rated total thermal burden 17 Rated insulation levels a) 1.2/50 micro-second Lightning impulse withstand voltage b) 1 minute dry power frequency withstand test voltage 18 Creepage distance 19 Radio Interference Voltage at 1 MHz at 105 kV rms for 132 kV system 20 Corona extinction voltage 21 a) b) c) 22 Overall dimensions & weights Width Height Weight Rated total thermal burden (Attach curve & state curve reference numbers)

(VA) (kV peak) (kV rms) (mm) (V) (kV rms) (mm) (mm) (Kg) (VA)

-40Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit (Deg. C)

Guaranteed Particulars

23 Temperature rise at 1.2 times rated primary voltage Continuous with rated burden after steady state conditions at normal rated voltage and burden 24 Temperature rise at 1.5 times rated voltage for 30 sec. 25 One minute power frequency withstand voltage on secondaries a) Winding No. I b) Winding No. II c) Winding No. III 35 One minute power frequency withstand voltage of HF terminal 36 Partial discharge level 37 Value of pressure for sealing test 38 Weight of oil and the standard to which it conforms a) In measuring unit 39 Quantity of oil 40 Total weight 41 Minimum center to center recommended spacing between PTs. 42 Clearance required from grounded equipment at various heights of PTs. 43 Mounting flange dimensional details 44 Compliance to technical specification (a) Bushing insulator (b) Control cabinet (c) Terminal connectors 45 Enclosures: Whether the following are enclosed with the tender i) All type test reports ii) Drawings as per specification iii) Technical literature for potential transformer and marshalling box.

(Deg. C)

(kV rms) (kV rms) (kV rms)

(pC) (kN/sq. m)

(Kg) (litres) (Kg) (mm) (mm)

(Yes/No) (Yes/No) (Yes/No)

(Yes/No) (Yes/No) (Yes/No)

-41Section - IX : Guaranteed & other Technical Particulars

F. METAL OXIDE SURGE ARRESTERS (120 kV & 30 kV) Sl. Description No. 1 Manufacturers Name and Address 2 Manufacturers type designation 3 Applicable technical standard 4 Arrester class and type 5 6 7 8 9 10 Rated voltage of arrester Rated system voltage Rated frequency Continuous Operating Voltage (COV) Nominal Discharge Current (8/20 micro sec.) a) No. of units in complete arrester b) Voltage rating of each unit c) Height of longest unit 11 Long duration discharge class 12 a) Minimum energy dissipation capability (kJ/kV of rated voltage of arrester) b) Power frequency over voltage withstand capability immediately after discharging energy equivalent to the minimum capability of arrester . 13 Leakage current at COV and ambient temperature a) Resistive component b) Capacitive component c) Total 14 Reference voltage and corresponding reference current guaranteed by manufacturer 15 Watt loss per kV at COV 16 Temporary power frequency over voltage withstand capability a) 0.03 sec (for 390 kV only) b) 0.1 sec c) 1.0 sec d) 10 sec e) 100 sec 17 Maximum residual voltage for a) Lightning impulse current (8/20 micro sec.) of - 5 kA - 10 kA - 20 kA b) Steep current impulse (1/20 micro sec) at Nominal Discharge Current 18 High current short duration impulse (4/10 micro sec) value 19 Low current long duration impulse current (2000 microsec.) 20 Whether pressure relief devices provided 21 Current for pressure relief test
(kV rms) (kV rms) (Hz) (kV rms) (kA) (Nos.) (kV rms) (mm)

Unit

Guaranteed Particulars

(kJ/kV) (kV rms)

(mA) (mA) (mA) (kV rms, kA rms) (Watts)

(kV rms) (kV rms) (kV rms) (kV rms) (kV rms)

(kV peak) (kV peak) (kV peak) (kV peak) (kA peak)

(Yes/No) (kA)

-46Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 22 Pressure relief class (As per IEC-99) 23 Prospective symmetrical fault current 24 a) High current value employed for pressure relief b) Low current value employed for pressure relief 25 Metal oxide discs: a) Country of manufacture b) Size of discs (Diameter & Thickness) c) How the electrical contact is ensured between blocks d) Medium of heat dissipation from the blocks to the surrounding 26 Arrester Housing: a) Name of manufacturer b) Wet power frequency with stand voltage c) Lightning impulse (1.2/50 micro sec.) withstand d) Total creepage distance e) Dry arcing distance f) Cantilever strength g) Internal diameter h) Thickness 27 Partial discharge level 28 Radio Interference level at 1.1 COV 29 30 31 a) b) c) Total height of arrester Toal weight of complete arrester unit Surge Monitor Type Minimum lightning impulse current (8/20 micro sec.) to which surge counter will respond faithfully Whether the surge monitor has been successfully tested for high current impulses, long duration current impulse & low current response test Scale range of leakage current meter Recommended protective distance from transformer Compliance to technical specification w.r.t. Surge Monitor Support insulator Terminal connectors Whether following curves/drawings enclosed with Volt time characteristic Voltage current characteristic of arrester Type test has been conducted as per IEC 60099 - 4 (latest edition) Type test report submitted along with the offer Drawing of outline dimensions for installation Drawing of mounting flange dimension detail Drawing of Earthing arrangement provided Details for surge monitor enclosed

Unit
(kA rms) (kA) (Amp)

Guaranteed Particulars

(mm, mm)

(kV rms) (kV peak) (mm) (mm) (N - m) (mm) (mm) (pC) (mV) (mm) (Kg)

(mA Amp) (Yes/No)

d) 32 33 a) b) c) 34 a) b) c) d) e) f) g) h)

(mA) (m) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

-47Section - IX : Guaranteed & other Technical Particulars

DC STATION BATTERY AND BATTERY CHARGERS I Sl. No. 1 2 3 4 i) ii) DC BATTERY Description Manufacturer's Name and Address Applicable standard Cell designation Plates: Type of positive plate Type of negative plate (Nos.) (mm) Unit Guaranteed Particulars

iii) Number of plates per cell 5 a) Thickness, type and material of separators b)Type of vent plug 6 7 8 i) ii) 9 10 11 12 13 14 15 i) ii) 16 i) ii) 17 18 19 a) Type of container b) Material of container Sediment space Open Circuit Voltage of each cell when completely discharged at 27 Deg. C At 10-hour discharge rate At one-hour discharge rate a) Trickle charging voltage range b) Trickle charging current Recommended Trickle charging voltage per cell and maximum variation Voltage per cell at the end of trickle charging. Boost charging voltage range Recommended boost charging rate at starting and finishing Voltage per cell at the end of boost charging and time taken for boost charging Capacity of battery at Ten hour discharge rate to 1.85 V per cell at 27 Deg. C One hour discharge rate to 1.75 V per cell at 27 Deg. C Internal resistance of each cell Fully charged Fully discharged Quantity and specific gravity of electrolyte for cell required for first filling at 27 Deg. C Specific gravity of electrolyte of fully charged cell at 27 Deg. C Maximum electrolyte temperature that cell shall withstand continuously without affecting the service life of cell Average life of cell in years

(mm)

(Volts) (Volts) (Volts) (Amps) (Volts, %) (Volts) (Volts)

(Volts, Hr) (AH) (AH)

(Ohms) (Ohms) (Litres)

(Deg. C)

20

(Years) (mm x mm) x mm) (mm)

21 Overall dimension of each cell 22 Distance between the centres of cell when

-94Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 23 Weight of cell complete with electrolyte 24 Size and material of connectors with method of connecting cells 25 Recommended period of storage before first charging 26 Size of cable recommended for connections of battery-to-battery charger, DC distribution board 27 Insulator material for rack and cells. 28 Battery racks i) Type of material ii) Whether anti-acid coating provided iii) Net weight 29 Short circuit current at battery terminals 30 Recommended maximum rating of fuse for protection of battery

Unit (Kg) (mm) (hr) (sq. mm)

Guaranteed Particulars

(Yes/No) (Kg) (Amps) (Amps)

31 Time for which the battery can withstand short (Sec) circuit at terminals 32 Amount of hydrogen evolved during boost 33 charging Recommended interval at which battery should be discharged at 10 hour discharge rate and boost charged. AH efficiency WH efficiency Equalizer charging current and frequency of equalizing charge recommended a) Type of inter cell connector (bolted/burnt) b) Material of inter cell connector During initial charging Recommended starting rate of charge Recommended finishing rate of charge Voltage of cell at the end of charge at finishing Enclosures Whether all the drawings and technical literature of Battery enclosed Whether type test reports enclosed

34 35 36 37 38 a) b) c) 39 a) b)

(%) (%) (Amp, Hz)

(Volts) (Yes/No) (Yes/No)

-95Section - IX : Guaranteed & other Technical Particulars

DC STATION BATTERY AND BATTERY CHARGERS II Sl. No. 1 2 3 4 BATTERY CHARGER Description Manufacturer's Name and Address Charger rated output current Charger rated output voltage Capacity of battery chargers Unit Guaranteed Particulars Float cum Float Boost

(Amp) (Volts) (AH)

5 Rectifier assembly a) Type of semi conductor material b) c) d) e) f) g) h) i) j) k) l) 6 7 a) b) c) d) 8 a) b) 9 10 a) b) c) d) e) f) g) h) i) j) 11 a) b) c) d) e) Rated direct current Rated direct voltage Continuous rating Rated input voltage Type of connection of rectifier elements (Full wave half/full controlled bridge) Maximum temperature rise over ambient of 38 Deg. C outside Short time rating and duration Short circuit current on the output terminal Peak inverse voltage of rectifier elements Overload capacity Applicable standard Load limiter current setting range for float charger Automatic voltage regulator (Float/Boost charger) Type Percentage stabilisation of the out put DC voltage Voltage setting range Response time Manual voltage regulator (Float/Boost charger). Type Voltage setting range a) Boost charging current setting range b) Boost charging voltage limit setting range Rectifier transformer Type Rated kVA and % impedance Turns ratio Primary winding connection in vector representation Secondary winding connection in vector representation Class of insulation One minute power frequency withstand voltage Over load capacity Applicable standard Whether short circuit test has been conducted Instruments Type DC voltmeter range DC Ammeter range Accuracy class as per IS Dial size -96Section - IX : Guaranteed & other Technical Particulars (Amp) (Volts) (Amp) (Volts)

(Deg. C) (Amp, Sec) (Amps) (Volts) (%) (Amp, %)

(%) (Volts, %) (ms)

(Amp, %) (Volts, %)

(kVA, %)

(kV rms) (%) (Yes/No)

(Volts) (Amp) (mm x mm)

Sl. No. 12 Contactor a) Type b) c) d) e) f) g) 13 a) b) c) 14 a) b) c) d) e) f) g) 15 a) b) c) 16 a) b) c) d) 17 a) b) 18 19 a) b) c) d) e) f) g) 20 a) b)

Description

Unit

Guaranteed Particulars Float cum Float Boost

Rated voltage Rated current No. of Power contacts Number, type and rating of auxiliary contacts Operating coil voltage Dropout voltage Thermal over load relay Tripping current range Whether single phasing protection provided Applicable standard Air break switches Type Rated voltage Rated current Type and material of contacts Applicable Standards Maximum through fault current withstand Rated making and breaking capacity Fuses Type Rupturing capacity Applicable standard Blocking diode Continuous rating Short time current rating Peak inverse voltage Type of semi conducting material Ripple content in DC output With battery Without battery Guaranteed efficiency at rated load Whether chargers provided with following features Automatic voltage regulators Automatic current regulators Soft start feature Smoothing resistor/capacitor filter circuit Selector switch for automatic and manual mode of operation Load linking circuitory Necessary RC network for protection of rectifier elements Enclosure : Whether all the drawings and technical literature for chargers enclosed Whether type test reports enclosed

(Volts) (Amp) (V, A, AC/DC) (Volts) (Volts) (Amp) (Yes/No)

(Volts) (Amp)

(kA) (kA)

(kA)

(Amp) (Amp) (Volts)

(%) (%) (%) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

(Yes/No) (Yes/No)

-97Section - IX : Guaranteed & other Technical Particulars

CONTROL AND RELAY PANELS Sl. No. A. 1 2 3 4 a) b) c) 5 6 7 Description Unit Guaranteed Parameters

CONTROL AND RELAY PANELS Name & Address of the manufacturer Make & Type Type of sheet steel Thickness of sheet steel Front Back Sides Degree of Protection Weight of each panel section Overall dimensions of each panel section (width x depth x height) 8 Total weight of all panels 9 Space required for installation of all panels 10 Details of tropicalization 11 Largest package for transport a) Gross Weight b) Overall Dimensions 12 a) b) 13 14 15 16 17 B. 1 2 3 4 5 6 7 8 9 C. 1 2 3 4 5 6 7 Details of painting Exterior Interior a) Lightning impulse withstand voltage b) Power frequency withstand voltage Descriptive literature/leaflet enclosed Ref. No. and date of type test certificate submitted Standards to which the panel conforms Details of foundation / embedment in foundation SEMAPHORE INDICATORS Make Type Diameter of the disc Operating voltage Burden Whether latch in mechanism provided Descriptive literature/ leaflet enclosed Ref. No. and date of type test certificate submitted Standard to which it conforms

(mm) (mm) (mm) (Kg) ( mm x mm x mm) (Kg) (Sq. m)

(Kg) (mm x mm x mm)

(kV peak) (kV rms) (Yes/No)

(mm) (Volts) (VA) (Yes/ No) (Yes/ No)

TERMINAL BLOCK Make Type & construction Applicable standard No. of terminal studs per way Rated current Rated voltage Materials used i) Body ii) Terminal -53-

(Nos.) (Amp) (Volts)

Section - IX : Guaranteed & other Technical Particulars

Sl. No. iii) iv) v) vi) vii) 8 9

Description

Unit

Guaranteed Parameters

Connecting Links Support springs Cover Label End stop Weight in kgs. Minimum No. of conductors of area 2.5 sq. mm suitable for connection i) All circuits except CT ii) CT circuits (4 sq. mm) 10 % of spare terminals on each panels 11 Whether shrouding provided for terminals of voltages more than 110 V AC / DC 12 Whether stud type brass terminals provided 13 Marking 14 Descriptive literature/ leaflet enclosed 15 Ref. No. and date of type test certificate submitted D. CONTROL SWITCHES 1 Make 2 Type of the switch 3 Type of handle (stay put or otherwise) 4 No. of possible positions of the handle with a) diagrams No. of contacts available in each position i) Open ii) Close b) Maximum No. of contacts which can be accommodated for each position 5 Rating of contacts a) Voltage b) Make and carry current continuously c) Make and carry current for 0.5 sec d) Break resistive load e) Break inductive load with L/R = 40 m. sec 6 Whether locking arrangement provided 7 Mounting details and Drawing No. 8 Dimensions 9 Other information, if any 10 No. of slip contacts (lost motion type) a) After close b) After trip c) Maximum No. of slip contacts possible 11 Standard to which it conforms 12 Detailed technical literature furnished 13 Ref. No. and date of type test certificate submitted E. INDICATING LAMPS 1 Make 2 Type 3 Ratings a) Current b) Voltage -54-

(Kg)

(Nos.) (Nos.) (%) (Yes/No) (Yes/No) (Yes/No)

(Nos.) (Nos.) (Nos.)

(Volts) (Amp) (Amp) (Amp) (Amp) (Yes/No) (mm)

(Nos.) (Nos.) (Nos.) (Yes/No)

(Amp) (Volts)

Section - IX : Guaranteed & other Technical Particulars

Sl. No. c) 4 5 6 a) b) 7 8 9 10 11 12 13 14 15 F. 1 2 3 4 5 6 7 8 9 10 G. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 H. 1 2

Description Wattage Colour of lamp Permissible voltage variation Whether series resistance is provided, if so Ohmic value Power loss Life of lamp in burning hours Other information, if any Size of lens Identification inscription Dimension and mounting details Voltage withstand on continuous basis as a percentage of rated voltage Descriptive literature/ leaflet enclosed Ref. No. and date of type test certificate submitted Standard to which it conforms PUSH BUTTONS Make Contact type (momentary/maintained) Whether shrouding provided to prevent inadvertent operation Whether integral engraved inscription plates provided No. of NO/NC contacts Make and carry capacity at 250 VDC Break inductive load capacity Descriptive literature/ leaflet enclosed Ref. No. and date of type test certificate submitted Standard to which it conforms ANNUNCIATORS Make and type No. of windows Dimensions of each window (length x height x depth) No. of lamps per window Auxiliary supply voltage Power consumption Details of auxiliary equipment such as relays etc. furnished Required instantaneous making capacity of initiating contacts Type of reset - (manual / self) Over all dimensions of annunciator Particulars of wiring enclosed Technical literature enclosed Brief write up of the scheme furnished Applicable standard INDICATING METERS Make and type Type of movement -55-

Unit
(Watts) (%) (Yes/No) (Ohms) (Watts) (Hours) (mm) (mm) (%) (Yes/No)

Guaranteed Parameters

(Yes/No) (Yes/No) (Nos.) (Amp) (Amp) (Yes/No)

(Nos.) (mm x mm x mm) (Nos.) (Volts) (Watt) (Yes/No) (Amp)

(mm x mm x mm) (Yes/No) (Yes/No) (Yes/No)

Section - IX : Guaranteed & other Technical Particulars

Sl. No. 3 4 a) 5 6 7 a) b) 8 9 10 11 12 13 14 15 16 a) b) 17 a) b) 18 a) b) c) 19 20 21 22 23 a) b) 24 25 26 27 I. 1 2 3 4 5 6 7 8 a) b) 9

Description

Unit

Guaranteed Parameters

Type of mounting Range Effective range CT ratio PT ratio Details of shunt, if any (Amp) Rated current (Volts) Rated voltage drop Accuracy class (Degrees) Total deflection angle Total scale length (mm) Dimension Reference condition of influencing quantities Limits of influencing quantities for its application Limit of error for variation of each of the influencing quantities Limits of error in effective range Power consumption Current coil Potential coil Burden Current coil Voltage coil Short time rating Current coil Voltage coil Time Other details Detailed literature furnished Weight Whether magnetically shielded or not Continuous over loading Current coil Potential coil Temperature at which the instruments are calibrated Ref. No. and date of type test certificate submitted Standard to which the instrument conforms. Descriptive literature/ leaflet enclosed ENERGYMETERS Make and size Type of measurement Measuring range CT ratio PT Ratio Current coil rating Voltage coil rating Accuracy at 125% , 10% and 25% of rated Active energy measurement Reactive energy measurement Power Consumption -56-

(Watts) (Watts) (VA) (VA) (Amp) (Volts) (Sec) (Yes /No) (Kg) (Yes /No) (Amp) (Volts) (Deg. C)

(Yes /No)

(Amp) (Volts)

Section - IX : Guaranteed & other Technical Particulars

Sl. No. a) b) 10 11 12 a) b) c) d) 13 a) b) c) d) 14 a) b) 15 a) b) 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 J. 1 2 3 4 5 6

Description Current coil Potential coil VA burden of current coil VA burden of potential coil Limits of error at UPF and Rated current 125% of rated current 25% of rated current 10% of rated current Limits of error at 0.5 PF (lag) and Rated current 125% of rated current 25% of rated current 10% of rated current Continuous overload rating of current coil For thermal limit For accuracy limit Short time overload rating of current coil Current Time Continuous over voltage rating of potential coil Reverse running stop provided Short time over voltage rating of potential coil

Unit
(Watts) (Watts) (VA) (VA)

Guaranteed Parameters

(Amp) (Amp) (Amp) (Sec) (Volts) (Yes/No) (Volts, Sec)

Standard to which it conforms Mounting details (Yes/No) Whether tropicalized (Volts) Auxiliary supply (Yes/No) Suitability for measurement on unbalanced 3 phase, 3wire System (Nos.) No. of digits on the meter (Watts) Starting watts at UPF Reference condition of influencing quantities Limits of influencing quantities for its application Temperature at which calibrated Weight Whether magnetically shielded or not? Limits of error in the effective range Descriptive literature/ leaflets submitted Testing facilities and other details, if any. Ref. No. & date of type test certificate submitted. RECORDING INSTRUMENTS Make and type Type of mounting Range of parameter that can be recorded Range of basic movement (in case of transducer operated system) Accuracy Range and choice of speeds -57(Deg. C) (Kg) (Yes/No)

(Yes/No)

Section - IX : Guaranteed & other Technical Particulars

Sl. No. 7 8 9 a) b) c) 10 11 12 13 14 15 16 17 K. 1 2 3 4 5 6 i) ii) iii) iv)

Description Paper width Length of chart Auxiliary supply Voltage Current Watts Permissible variation in auxiliary supply Burden Type of case (draw out/non draw out) Detailed technical literature furnished Particulars of drive Form of reserve drive Details of arrangement for time synchronization Standard to which the recorder conforms DISTURBANCE RECORDER Name of manufacturer Manufacturers type designation Standards according to which disturbance recorders and event recorder are manufactured Over rated voltage Frequency Data Acquisition Unit Resolution time for data acquisition Whether micro processor based or not Rate of scanning of analogue and digital quantities Analysis of recording of analogue quantities Type of channel AC/DC Current AC/DC Volts Watts / VAR / carrier Zero seq. voltage Multiphase voltage Period/frequency Negative sequence voltage Rate of sampling Sensor details i) Current swing ii) Voltage swing iii) 3 phase under voltage iv) 3 phase over voltage v) 1 phase under voltage vi) 1 phase over voltage vii) 3 & 1 phase over current viii) Rate of change of voltage ix) 3 phase. Neg. sequence voltage x) 3 phase zero sequence voltage xi) Over/under frequency xii) DC over/under level Stability of sensor trip setting Recorder: -58-

Unit
(mm) (mm) (Volts) (Amp) (Watts) (%) (VA) (Yes/No)

Guaranteed Parameters

(Volts) (Hz) (ms) (Yes/No) (Hz / Channel)

v) 7 a)

b) 8

(%)

Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. i) Type ii) Type of paper used iii) Recorder chart speed (% of rated speed for prefault & postfault period)

Unit

Guaranteed Parameters

-59Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. iv) Response time a) Transient response time suitable to resolve breaker pole timing and restrike wave forms b) % over shoot v) Phase accuracy at 50 Hz vi) vii) viii) ix) x) xi) xii) xiii) L. i) ii) iii) 1 i) ii) iii) iv) v) vi) vii) 2 i) 50 Hz interference (P-P) Fluctuations due to zero trace noise (peak to Full scale & division Trace width Record clarity Gain stability Linearity & distortion Amplitude resolution Details of event Logger/ Recorder Type Width space occupied on chart Operating input current Isolation levels Isolation levels Circuit breaker AC input Events DC power Alarms AC sync. Overload ratings of Channel AC Current a)Continuous Rating b)1 min. Rating c)1 sec. Rating AC Potential a)Continuous Rating b)1 min. Rating c)1 sec. Rating Printer Characteristics Type Type of paper used Test frequency of oscillation Test pulse repetition period Test duration Peak test voltage Calibration Devices Current Voltage Accuracy Real time clock Type Accuracy Type of controls provided for maintenance and calibration Power supply -60Section - IX : Guaranteed & other Technical Particulars

Unit
(ms) (%) (%)

Guaranteed Parameters

(mm) (%)

(Amp) (Amp) (Amp) (Volts) (Volts) (Volts)

ii)

3 i) ii) iii) iv) v) vi) 4 i) ii) iii) 5 a) b) 6 7

(Hz) (ms) (Sec) (kV)

Sl. Description No. i) Power Consumption ii) Frequency Variation iii) Voltage Fluctuation for AC - % and for DC - % 8 Service life of the equipment 9 Overall dimensions of the equipment 10 Weight 11 Whether type test certificates submitted 12 Whether details of principles, details of individual equipment have been submitted 13 Descriptive literature/ leaflets enclosed. M. FAULT LOCATORS 1 Make 2 Type 3 4 5 6 7 8 9 i) ii) 10 11 12 13 i) ii) iii) Reference standards Rated current & or voltage Rated DC voltage Operating principle Solid state / electro mechanical / Numerical Thermal rating Number of contacts Normally Open Normally Closed Contacts self reset / hand reset Burden Operation indicator provided Contact rating Make and carry continuously Make and carry for 0.5 sec Break a) Resistive load b) Inductive load (with L/R = 40 milli sec.)

Unit
(Watts) (%) (%) (%) (Years) (mm) (Kg) (Yes/No) (Yes/No) (Yes/No)

Guaranteed Parameters

(A, V) (V DC)

(Amp) (Nos.) (Nos.) (VA) (Yes/No) (Amp) (Amp) (Amp) (Amp) (ms) (ms) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

14 i)Maximum registering time ii) Time to locate Fault 15 Whether direct display unit provided? If so, details to be given. 16 Whether a printer included? If so, details to be given 17 DC/DC converter included? 18 Separate phase and each fault features provided 19 Descriptive literature enclosed N. DIRECTIONAL COMPARISON RELAY 1 2 3 Scheme Type/Designation Operating time (min & max.) VA burden a) Current circuits b) Voltage circuits c) DC Circuits -61Section - IX : Guaranteed & other Technical Particulars

(ms) (VA) (VA) (VA)

Sl. Description No. 4 Type of Directional comparison provided (Continuous / Discontinuous) 5 Full details of literature, illustrations & application checks submitted 6 Type of carrier channel required. 7 Particulars of carrier channel required a) Transmitter frequency range b) Center frequency c) Transmitter output power 8 Power supply required with variation tolerance 9 10 11 12 13 14 15 16 Size of the equipment Weight of the equipment Type of operational phase selector Ambient temperature range Dielectric test voltage Impulse withstand test voltage Disturbance test voltage Type of operation mode of relay (independent / dependent) 17 The following details for Main I & II protection schemes shall be submitted with the tender. i) Detailed block diagram ii) Detailed internal Circuit diagram with terminal details for external wiring and power supply iii) details Drawings giving details of dimensions & iv) installation Type test reports v) Is it suitable for 220 V DC vi) Phase selector distance included for single and three phase tripping? vii) DC/DC converter included? viii) Operating time (maximum ) of phase selector relays for Zs/Z1 = 15. 18 The relay shall not mal operate for CVT 19 transients Stability angle limit range 20 Particulars of time/current, voltage setting ranges and steps etc. as well as any other data required for guaranteeing performance of the remaining relays included in the specification (inclusive of dead line charging relays, synchronizing check relays, neutral displacement relays, over fluxing relays etc.) shall be submitted herein. Standards to which the relays conform. The Sensitivity and selectivity of receiver. DISTANCE RELAYS Make Type Type of distance measuring and number of measuring elements Starting unit -62Section - IX : Guaranteed & other Technical Particulars

Unit

Guaranteed Parameters

(Yes/No)

(Hz) (Hz) (Watts) (Volts, %) (mm) (kg) (Deg. C) (kV) (kV) (kV)

(Yes/No) (Yes/No)

(Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (ms) (Yes/No) (Degrees)

21 22 O. 1 2 3 4

Sl. No. a) b) c) 5 b) 6 7 8 9 a) b) c) 10 a)

Description Is a separate directional relay provided or The distance element is directional Type and number of starting unit a)Number of zones First zone element taps are variable in steps of Second zone element taps are variable in steps of Third zone element taps are variable in steps of If Mho unit has any OFF SET setting possible and if so, range Operating time First zone timing Second zone timing adjustable between Third zone time adjustable between Contact ratings First zone

Unit
(Yes/No) (Yes/No)

Guaranteed Parameters

(Yes/No)

(ms) (ms) (ms) (V, A, AC/DC) (V, A, AC/DC) (V, A, AC/DC) (VA) (VA) (VA) (Yes/No) (Yes/No) (Degrees) (Yes/No) (Ohms) (ms) (%) (%) (Amp) (Amp, Sec) (Volts) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Nos.) (Yes/No)

b) Second zone c) Third zone 11 a) b) c) 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 P. 1 2 3 4 5 6 7 8 VA burden of each phase Current coil Potential coil DC circuits Whether seal in contacts are provided? Technical literature furnished Setting range of characteristic angle Whether under voltage relays are provided Continuously variable ohmic range Maximum resetting time Range of adjustable offset features Residual compensation range Continuous current rating Short time current rating and time Continuous voltage rating Whether high- speed trip relays are included. Whether power swing blocking incorporated. Whether CVT fuse failure protection included. Whether out of step tripping relays included. Number of potential free contacts provided. Whether continuous DC supply supervision provided. Standard to which the relays conform. AUTO RECLOSE RELAY Make Type Reference standards Rated current and/or voltage Rated DC voltage Operating principle Electromechanical/static/Numerical Thermal rating -63Section - IX : Guaranteed & other Technical Particulars

(A, V) (Volts)

(Amp)

Sl. No. 9 a) b) 10 11 12 13 i) ii) iii)

Description Number of contacts Normally Open Normally Closed Contacts - (self reset / hand reset) Burden Operating indicator provided? Contact ratings and configuration Make and carry continuously Make and carry for 0.5 sec. Break Resistive load Inductive load (with L/R = 40 ms) Suitable for single and three phase (single phase/ three phase) Single phase dead time setting range Three phase dead time setting range Reclaim time setting range Whether check synchronizing and dead line charging relays included as a part of the auto reclose scheme. Whether four position selector switch is included ? Whether single shot or multi shot. Whether pole discrepancy relay included Descriptive literature/ leaflet enclosed Whether lock out facility provided Any other relevant information DIFFERENTIAL RELAYS Makers name Type Current coil rating Maximum VA burden Operating coil Restraining coil Power consumption of Operating coil Restraining coil Is the slope setting variable Harmonic restraint provided or not with details. Is 5th harmonic by pass provided? Range of HT/LT ratios over which the relay can be used Details of auxiliary CTs. Operating time At 2 x In At 10 x In At 5 x In Descriptive literature/ leaflet enclosed Contact rating Make and carry continuously Make and carry for 0.5 sec.

Unit
(Nos.) (Nos.) (VA) (Yes/No) (Amp) (Amp) (Amp) (Amp)

Guaranteed Parameters

14 15 16 17 18 19 20 21 22 23 24 Q. 1 2 3 4 i) ii) 5 i) ii) 6 7 8 9 10 11 a) b) c) 12 13 a) b)

(Sec) (Sec) (Sec) (Yes/No) (Yes/No)

(Yes/No) (Yes/No) (Yes/No)

(Amp) (VA) (VA) (Watts) (Watts) (Yes/No) (Yes/No) (Yes/No)

(ms) (ms) (ms) (Yes/No) (Amp) (Amp)

-64Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. c) Break Resistive load and inductive load (with L/R = 40 milli sec.) 14 Type of mounting 15 No. of pair of make and break contacts 16 Pick up/drop off ratio 17 Resetting time 18 Normal voltage 19 Permissible variation in voltage 20 Nominal current (in case of current operated 21 relays) Permissible variation in current 22 23 24 25 R. 1 2 3 4 5 6 7 8 9 i) ii) 10 11 12 13 i) ii) iii) Type of casing and available number of terminal Standards to which the relays conform. Whether Disturbance Recorder provided No. of instantaneous high set over current units TRANSFORMER OVER FLUXING RELAY Make Type Reference standards Rated current & or voltage Rated DC voltage Operating principle Solid state or electro mechanical or Numerical

Unit
(Amp)

Guaranteed Parameters

(Nos.) (ms) (Volts) (%) (Amp) (%) (Nos.)

(Yes/No) (Nos.)

(A, V) (Volts)

14 a) b) c) 15 16 17 S.

1 2

(Amp) Thermal rating Number of contacts (Nos.) Normally open (Nos.) Normally closed Contacts self reset / hand reset (VA) Burden (Yes/No) Operation indicator provided Contact rating (Amp) Make and carry continuously (Amp) Make and carry for 0.5 sec Break (Amp) a) Resistive load (Amp) b) Inductive load (with L/R = 40 ms) Setting ranges (%) V/f (Sec) Time for alarm (ms) Time for tripping (Yes/No) Detailed literature enclosed (%) Resetting Ratio Whether provided on both HV and IV sides of the (Yes/No) transformers OVER CURRENT AND EARTH FAULT RELAY I. NON - DIRECTIONAL Makers name Type & reference standard

-65Section - IX : Guaranteed & other Technical Particulars

Sl. No. 3 4 i) ii) 5 6 7 8 9 i) ii) 10 i) ii) 11 12 13 i) ii) iii) 14 15 16 i) ii) 17 1 2 3 i) ii) 4 5 6 i) ii) iii) iv) 7 i) ii) 8 9 10 11 T. 1 2

Description Current coil rating VA burden Highest tap Lowest tap Rated DC voltage Operating principle Thermal rating Rated current & or voltage Power consumption Highest tap Lowest tap Time of operation at 5 times tap setting current 10 times tap setting current Type of characteristics Descriptive literature/leaflets enclosed Contact ratings Make and carry continuously Make and carry for 0.5 sec Break resistive load and inductive load with 40 milli sec. time constants No. of pair of make and break contacts Directional sensitivity Over current unit setting range Inverse time High set instantaneous unit Maximum torque angle II. DIRECTIONAL Makers name Type Polarization Current Potential Current coil rating Potential coil rating VA burden Current coil Highest tap Lowest tap Potential coil Time of operation at 5 times tap setting 10 times tap setting Type of characteristic Descriptive literature / leaflet enclosed Applicable standards Dimensions / weights RESTRICTED EARTH FAULT RELAY Make Type -66-

Unit
(Amp) (VA) (VA) (Volts) (Amp) (A, V) (Watts) (Watts) (ms) (ms) (ms) (Yes/No) (Amp) (Amp) (Amp) (Nos.) (%) (ms) (Degrees)

Guaranteed Parameters

(Amp) (Volts) (VA) (VA) (VA) (VA) (ms) sec (Yes/No) (mm, Kg)

Section - IX : Guaranteed & other Technical Particulars

Sl. No. 3 4 5 6 7 8 9 i) ii) 10 11 12 13 14 15 16

Description Reference standards Rated current & or voltage Rated DC voltage Operating principle Solid state or electro mechanical or Numerical Thermal rating Number of contacts Normally Open Normally Closed Case dimensions (Overall )

Unit
(A, V) (Volts)

Guaranteed Parameters

(Amp) (Nos.) (Nos.) (mm x mm x mm) (mm x mm) (Kg) (VA) (Yes/No) (Amp) (Amp) (Amp) (Amp) (ms) (Yes/No) (%) (Ohms)

Cut out dimensions (height x width) Weight Contacts self reset/ hand reset Burden Operation indicator provided Contacts ratings i) Make and carry continuously ii) Make and carry for 0.5 secs iii) Break a) Resistive load b) Inductive load (with L/R = 40 ms) 17 Operating time at 2 x setting current 18 Tuned to system frequency? 19 Setting range 20 Is it with high impedance with stabilizing resistor or not? If so, value / range of stabilizing resistor 21 22 23 24 25 U. 1 2 3 4 5 Detailed literature / leaflet enclosed Current setting range Operating time Voltage setting range No. of alarm and trip output contacts BUS BAR PROTECTION RELAY Make and type designation General design (Static modular / EM / Numerical) Impedance type (Low / High/ moderately high)

(Yes/No) (%) (ms) (%) (Nos.)

Principle of operation Time of operation (ms) i) At 5 times the setting (ms) ii) At 10 times the setting if applicable (Amp, VA) 6 Current rating and burden (Volts) 7 DC supply (Yes/No) 8 Whether relay is suitable for all types of faults (Yes/No) 9 Whether separate CT core required? (Yes/No) 10 Whether aux. CTs required and if yes state whether these are built in or to be provided separately? 11 Whether relays can perform correctly even under (Yes/No) CT saturation condition?

-67Section - IX : Guaranteed & other Technical Particulars

Sl. Description Unit No. (Yes/No) 12 Whether relay remains stable for severe through faults? (Yes/No) 13 Whether check feature available built in (Yes/No) 14 Type of indicators provided? (Amp) 15 Output contact ratings and configuration? (Nos.) 16 Maximum number of feeders/circuits that can be connected to the relay (Yes/No) 17 Whether CT secondary open circuit supervision facility available (Yes/No) 18 Whether isolator auxiliary contact monitoring provided (Yes/No) 19 Non linear voltage limiting resistors included for each zone? (Yes/No) 20 Does the scheme give 100 % security and reliability during all system operating conditions? 21 Any other relevant information 22 Applicable standards (Yes/No) 23 Whether high speed hand reset tripping relay provided (Yes/No) 24 Whether protection in/out switch provided (Yes/No) 25 Whether DC supply supervision / DC fail alarm included (Yes/No) 26 Whether lockout trip relay provided (Yes/No) 27 Is the relay self-monitoring (Yes/No) 28 Whether on line testing facility provided (Yes/No) 29 Descriptive literature / leaflets enclosed (mm, Kg) 30 Dimensions / weights of the relay V. CIRCUIT BREAKER FAILURE RELAY 1 2 3 4 5 6 7 8 i) ii) 9 a) b) 10 11 i) ii) 12 Make Type Reference standards Rated current & or voltage Rated DC voltage Operating principle Thermal rating Number of contacts Normally Open Normally Closed VA Burden At lowest tap At highest tap Operation indicator provided? Contact ratings Make and carry continuously Make and carry for 0.5 secs Solid state or electro mechanical or numerical

Guaranteed Parameters

(A, V) (Volts) (Amp) (Nos.) (Nos.) (VA) (VA) (Yes/No) (Amp) (Amp)

13 Operating time a) At 5 times tap setting b) At 10 times tap setting

(ms) (ms)

-68Section - IX : Guaranteed & other Technical Particulars

Sl. No. 14 15 a) b) 16 a)

Description

Unit
(ms) (%) (%) (Yes/No) (Sec) (Yes/No) (%)

Guaranteed Parameters

Resetting time Setting range for current for : Phase over current Ground over current Timers Whether separate timers are provided for each phase? b) Setting range of timers. 17 Descriptive literature / leaflets enclosed 18 Reset / pick up ratio of the relay W. TRIP CIRCUIT SUPERVISION RELAY 1 2 3 4 5 6 7 8 9 i) ii) 10 11 12 13 i) ii) iii) Make Type Reference standards Rated current & or voltage Rated DC voltage Operating principle Solid state or electro mechanical or numerical Thermal rating Number of contacts Normally Open Normally Closed Contacts - (self reset/ hand reset) Burden Operation indicator provided? Contact ratings Make and carry continuously Make and carry for 0.5 secs Break a) Resistive Load b) Inductive Load (with L/R=40 ms) Whether pre closing and post closing supervision provided? Time delay Whether external resistors are provided. If yes, the value of the resistor Descriptive literature / leaflet enclosed AUXILIARY CTs AND VTs Make Type and standard to which it conforms Ratio Rated output Class of accuracy Short time rating Current Voltage Knee point voltage for Class PS Excitation current for Class PS duty at

(A, V) (Volts)

(Amp) (Nos.) (Nos.) (VA) (Yes/No) (Amp) (Amp) (Amp) (Amp) (Yes/No) (ms) (Yes/No) (Yes/No)

14 15 16 17 X. 1 2 3 4 5 6 a) b) 7 8

(VA)

(Amp) (Volts) (Volts)

a) KPV -69Section - IX : Guaranteed & other Technical Particulars

(mA)

Sl. No. b) 9 a) b) 10 11 12 13 14 15 16 17 Y. 1 2 i) ii) iii) iv) 3 4 5 6 7 8 9 Z 1 2 3 4 5 6

Description 50 percent KPV Internal impedance of Primary Secondary Temperature rise Mounting details Overall dimensions Any other details One minute power frequency withstand voltage Weight Location where these are to be used / mounted. Descriptive literature / leaflets enclosed PANEL WIRING Insulation of wiring Size of wiring conductor for the following PT circuits CT circuits DC supply circuits Other circuits Size of earthing bar for safety earthing Type of terminal provided on wiring Wiring conductor (aluminum/copper) Whether ferrules and insulated sleeves provided? Type and size of lugs provided Applicable standards Descriptive literature / leaflets / circuit diagrams enclosed? TRANSDUCER Make Type Applicable standards Rated input Rated output

Unit
(mA) (Ohms) (Ohms) (Deg. C) (mm) (kV rms) (Kg) (Yes/No)

Guaranteed Parameters

(sq. mm) (sq. mm) (sq. mm) (sq. mm) ( sq. mm)

(Yes/No) (sq. mm) (Yes/No)

(A, V, AC/DC) (A, V, AC/DC) (Nos.) (Nos.) (Sec) (%) (Ohms) (Deg. C) (mm, Kg) (Yes/No)

Terminal connectors a) No. of input terminal connectors b) No. of output terminal connectors 7 Response time 8 Accuracy class 9 AC ripple content 10 Suitable for load resistance 11 Temperature range 12 Dimensions/weight 13 Descriptive literature / leaflets enclosed? AA. RELAY TESTING SET 1 Makers name 2 Type 3 Capacity of loading transformer 4 Primary voltage 5 Secondary current and voltage 6 Electric / electronic timing meters -70Section - IX : Guaranteed & other Technical Particulars

(kVA) (Volts) (A, V)

Sl. No. a) b) 7 a) b) c) d) e) 8 9 10 AB. 1 2 3 4 5 6 7 8 AC. 1 2 3 4 5 6 AD. 1 2 3 4 5 6 7 8 9 AE. 1 2 3 4 5 6 7 8 9 AF. 1

Description Operating voltage Accuracy Instruments Make Current range Voltage range Accuracy class Standards to which applicable Descriptive literature enclosed Relay test kit supplied Distance Relay test kits supplied BUS BAR TRIP RELAY Make & type designation General design Operating Time Number & rating of trip contacts Burden Any other feature Applicable standards Descriptive literature / leaflet enclosed? TRIP CIRCUIT SUPERVISION RELAY Make & type designation General design DC rating Burden Type of indication Any other relevant details DC SUPPLY SUPERVISION RELAY Manufacturers Name & Country Type of Relay DC rating VA Burden No. of potential free output contacts Any other data Time delay on drop off Operation indication / flag provided? Applicable standards MASTER TRIP RELAY FOR TRANSFORMERS (for HV & LV intertrip) Manufacturers Name & Country Type of Relay DC rating VA Burden Operating time Number of output contacts and contact rating Any other details Applicable standards Descriptive literature / leaflets enclosed? ENERGY METER Make & type designation -71-

Unit
(Volts)

Guaranteed Parameters

(Amp) (Volts)

(Yes/No) (Yes/No) (Yes/No)

(ms) (A, V, AC / DC) (VA)

(Yes/No)

(A, V) (VA)

(A, V) (VA) (Nos.) (ms) (Yes/No)

(A, V) (VA) (ms) (A, V, AC/DC)

(Yes/No)

Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 2 Type 3 Accuracy 4 Whether suitable for 3 phase balanced and unbalanced loads 5 Any other relevant data AG. SELECTOR SWITCHES 1 Make & type designation 2 Current rating of contacts 3 Number of contacts in each position a) Open b) Closed 4 Number of ways 5 Number of positions 6 Type of handle 7 Whether stay put type 8 Whether locking facility provided. 9 Applicable standards 10 Descriptive literature / leaflets enclosed? AH. BREAKER / ISOLATOR AUXILIARY CONTACT MULTIPLICATION RELAY 1 Make & type designation 2 Rating & burden 3 No. of NO/NC contacts 4 Rating of contacts 5 Applicable standards 6 Descriptive literature / leaflets enclosed? AI. EARTHING 1 Material of conductor 2 Size 3 Type of end connection 4 Whether sufficient number of terminal connectors and clamps are supplied? 5 Size of copper wires for earthing 6 Detailed earthing scheme enclosed? AJ. CIRCUIT LABELS 1 Material, size, colour 2 Size and colour of lettering AK. MISCELLANEOUS 1 Tools Whether following tools included in the scope i) Special erection tools ii) Maintenance tools 2 Spares Whether list of recommended spares for normal maintenance for a period of 5 years furnished 3 Drawings Whether following items submitted. i) General arrangement drawings ii) Schematic drawings iii) Technical & descriptive literatures of all the components supplied -72Section - IX : Guaranteed & other Technical Particulars

Unit

Guaranteed Parameters

(Yes/No)

(Amp) (Nos.) (Nos.) (Nos.) (Nos.) (Yes/No) (Yes/No) (Yes/No)

(A, V, VA) (Nos.) (A, V) (Yes/No)

(sq. mm) (Yes/No) (sq. mm) (Yes/No) (mm x mm) (mm)

(Yes/No) (Yes/No) (Yes/No)

(Yes/No) (Yes/No) (Yes/No)

Sl. Description No. 4 Test Certificates Whether all the test certificates as listed below are furnished: i) Type test certificates for the following a) Relays b) ICTs c) IVTs AL. TIME SYNCHRONISATION EQUIPMENT 1 Manufacturers Name & country 2 Manufacturers type & designation 3 Reference standards 4 Name of satellite system & type of time signal 5 Number of satellites that can be tracked 6 a) Accuracy b) Minimum number of satellites required to be tracked for 1 (ms) accuracy 7 Acquisition time a) Cold start b) Warm start 8 Number of output ports 9 Whether able to give real time IST (Indian Standard Time) corresponding to (taking into consideration all factors like voltage temperature variation & propagation processing delay 10 Periodicity of time correction facility 11 Whether equipment is compatible for synchronization of event logger, disturbance recorder & SCADA at Substation 12 Whether output signal programmable at site 13 Separate time delay unit provided? 14 Operating temperature range 15 Storage temperature range 16 Dimensions of equipment / weight 17 Power supply (in volts, with permissible 18 Power consumption 19 Size of antenna 20 Weight of antenna 21 Accuracy of the equipment 22 Whether all accessories (e.g. cables, processing equipment, etc.) supplied? 23 Various combinations of outputs selectable by the customers 24 Whether real time display in hour, minute and seconds (24 hour mode) provided? 25 Whether spares consisting of 1 set of PCB cards of each type supplied? 26 Descriptive literature / leaflets enclosed?

Unit

Guaranteed Parameters

(Yes/No) (Yes/No) (Yes/No)

(Nos.) (mSec) (Nos.)

(ms) (ms) (Nos.) (Yes/No)

(Sec) (Yes/No)

(Yes/No) (Yes/No) (Deg. C) (Deg. C) (mm, Kg) (Volts, %) (Watts) (mm) (Kg) (mS) (Yes/No)

(Yes/No) (Yes/No) (Yes/No)

-73Section - IX : Guaranteed & other Technical Particulars

AY PANELS Guaranteed Parameters

-74Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-75Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-76Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-77Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-78Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-79Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-80Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-81Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-82Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-83Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-84Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-85Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-86Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-87Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-88Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-89Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-90Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-91Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-92Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-93Section - IX : Guaranteed & other Technical Particulars

Guaranteed Parameters

-94Section - IX : Guaranteed & other Technical Particulars

C. Sl. No. I. 1 2 3 a) b) 4 5 a) b) 6 a) b) c) 7 8 9 10 11 12 a) b) II. 1 2 3 4 5 6 7 8 9 10 III. 1 2 3 4 5 6 7 8 9 IV.

AC/DC DISTRIBUTION BOARD. Description GENERAL Rated Voltage Symmetrical short circuit withstand current of switchgear cubicle Degree of protection as per IS: 13947 Breaker / AC & DC distribution cubicles. Bus bar chamber. Cubicle sheet metal thickness for front, rear, sides and top. Painting shade as per IS:5 External surface Internal surface Standard height, width & depth of typical panel. Air circuit breaker panel Switch fuse cubicle. AC/DC Distribution Board. Width of cable alley Earth bus bar size and material. Recommended dynamic loading for foundation design. Approximate weight of AC/DC Distribution Is extension possible in future. Clearance in air Between phases Between phase and earth CURRENT TRANSFORMERS Manufacturer's Name Applicable standard Ratio Rated output Accuracy class Instrument Security Factor (ISF). Insulation level Nominal rated voltage Short time thermal rating for 1 sec. Class of insulation. POTENTIAL TRANSFORMERS Manufacturer's Name Applicable standard Rated primary voltage Rated Secondary voltage Accuracy class Insulation level Rated Burden Over voltage factor Class of insulation AIR CIRCUIT BREAKER -98Unit Guaranteed Particulars ACDB
(Volts) (kA)

DCDB

(mm)

(mm) (mm) (mm) (mm) (mm x mm) (N) (Kg) (Yes/No) (mm) (mm)

(kV rms) (kV) (kA rms )

(Volts) (Volts) (kV rms) (VA)

Section - IX : Guaranteed & other Technical Particulars

Sl. No. 1 2 3 4 5 6 7 8 9 10 11 12 13

Description Name of manufacturer and country Manufacturer's type designation Applicable standard Rated voltage Rated current at design ambient temperature Continuous current at site ambient temperature. Rated symmetrical breaking current Rated making current Short time current rating Short circuit performance category Temperature rise of main contacts when carrying continuous current Thickness of silver coating for main contacts Number of operations circuit breaker can make without inspection replacement of contacts or other parts at 100% rated breaking current. a) Number of auxiliary contacts provided and their rating. b) Total operating time c) Whether trip free or fixed trip type Operating mechanism (for ACB only.) Motor rating Time for fully charging the closing spring Emergency manual charging facility provided Limits of voltage for satisfactory operation of following devices, as percentage of normal voltage. i) Motor ii) Closing Coil iii) Tripping Coil Air break switches Type, make Rated voltage Rated current Type and material of contacts Applicable standard Maximum through fault current withstand Door inter locks provided Rated making and breaking capacity Fuses Make Type Rupturing capacity Peak cut-off current Whether mounted on insulated carrier Rated operating Duty BUS BARS AND INSULATORS Material and applicable standard

Unit

Guaranteed Particulars ACDB DCDB

(kV) (Amps) (Amps) (kA) (kA) (kA, sec) (Deg. C) (microns)

14

(Amps)

(ms)

15 a) b) c) d)

(V, A, Watts) (Sec) (Yes/No)

(%) (%) (%)

16 a) b) c) d) e) f) g) h) 17 a) b) c) d) e) 18 V. 1

(Volts) (Amps)

(kA) (Yes/No) (kA)

(kA) (kA) (Yes/ No)

-99Section - IX : Guaranteed & other Technical Particulars

Sl. No. 2 3 a) b) 4 5 a) b) 6 7 8

Description Bare/Painted/Epoxy insulated/Sleeved Minimum clearance Phase to phase Phase to earth Continuous current rating at ambient temperature Minimum Cross section provided for Horizontal bus bar Vertical bus bar Short time current rating for 1 sec. Material of the support insulators.

Unit

Guaranteed Particulars ACDB DCDB

(mm) (mm) (Deg. C) (sq. mm) (sq. mm) (kArms) (Deg. C) (Yes / No) (kApeak)

Temperature rise over ambient temperature for continuous current rating 9 Whether bus joints are silver faced 10 Dynamic current withstand rating VI. CONTACTORS 1 Make 2 Type and applicable standard 3 No. of poles 4 Rated voltage of main and auxiliary contacts. 5 Limits of operation a) Supply voltage variation b) Supply frequency variation for closing. c) Drop out voltage 6 Rated breaking capacity 7 Rated making capacity 8 Rated thermal current 9 Maximum recommended back up HRC fuse size. 10 Rated operating duty 11 Rated voltage of coils VII. AUXILIARY CONTACTOR 1 Make 2 Type 3 Coil voltage 4 Coil burden 5 No. of contacts and their rating VIII. 1 2 3 4 5 6 7 IX. 1 2 3 CONTROL / SELECTOR SWITCH Make Type Type of handle Number of contacts Rating of contacts No. of positions Contact material and plating PUSH BUTTONS Make Contact type Number of contacts ( NO+ NC) -100Section - IX : Guaranteed & other Technical Particulars

(Nos.) (Volts) (+/-%) (+/-%) (Volts) (kA) (kA) (kA) (Amp) (Volts)

(Volts) (VA) (V, A, AC/DC)

(Nos.) (V, A, AC/DC) (Nos.)

(Nos.)

Sl. No. 4 X. 1 2 3 4 5 XI. 1 2 a) b) 3 a) b) 4 5 6 7 XII. 1 2 3 4 5 6 7 8 9 10 11 XIII. 1 2 3 4 XIV. 1 a) b) c) d) e) f) g) h) 2 Contact rating

Description

Unit
(V, A, AC/DC)

Guaranteed Particulars ACDB DCDB

SPACE HEATERS Make Type Rated Voltage Thermostat setting range Heater output WIRING AND TERMINAL BLOCKS Voltage grade of wires Minimum size of conductor for Power wiring Control wiring Type of control terminal block on:Fixed portion and draw out portion Switchgear and breaker Make and type of terminal blocks Current rating of terminal blocks Insulation of wires Conductor material RELAYS Make Type Application Operating principle Coil burden Setting range Number of contacts Contact rating Contacts - (self reset or hand reset) Operation indicator provided Time of operation INDICATING LAMPS Make Type Voltage Series resistor value and rating INDICATING INSTRUMENTS Voltmeter Make Type Accuracy class Voltage coil rating Voltage coil burden Case size Angle of defelection Scale length Ammeter

(Volts) (Deg. C) (Watts) (Volts) (sq. mm) (sq. mm)

(Amp)

(VA) (%) (Nos.) (V, A, AC/DC) (Yes/No) (ms)

(Volts) (Ohms, Amp)

(Volts) (VA) (mm x mm) (Degrees)

-101Section - IX : Guaranteed & other Technical Particulars

Sl. No. a) b) c) d) e) f) g) h) XV. 1 2 3 4

Description Make Type Accuracy class Current coil rating Current coil burden Case size Angle of defelection Scale length ENCLOSURES Whether all the drawings as indicated in the specification enclosed. Whether all type test reports enclosed Whether characteristics of various types of relays for MCCB enclosed. Whether calculations furnished in support of adequacy of bus bar size (AC bus/DC bus) for specified current rating.

Unit

Guaranteed Particulars ACDB DCDB

(Amp) (VA) (mm x mm) (Degrees)

(Yes/No) (Yes/No) (Yes/No) (Yes/No)

-102Section - IX : Guaranteed & other Technical Particulars

D.
Sl. No. 1 2 3 4 5 a) b) c) d)

POWER AND CONTROL CABLE - XLPE CABLE Description


Unit 3Cx300 3.5Cx240

6 7 a) b)

Name & Address of the manufacturer Applicable standard Cable type designation Voltage rating (Volts) Conductor Material of conductor and flexibility class as per IS:8130 Size of conductor (sq. mm) Is conductor stranded (Yes/No) Stranded conductor i) Number of strands in each core ii) Size of strand (sq. mm) iii) Shape of the stranded conductor iv) Maximum DC resistance at 20 deg C (Ohms)/ Km) Number of cores Insulation Insulation material and type designation Minimum thickness of insulation (mm) (%) (Ohm-cm)

c) Tolerance on the measured value of thickness d) Minimum volume resistivity at 27 deg. C, 70 deg. C and 90 deg. C 8

Sheath a) Material for inner sheath, type of sheathing (extruded or wrapped) and type designation as per IS:5831. b) Material for outer sheath, type of sheathing (extruded or wrapped) and type designation as per IS:5831. c) Thickness of inner sheath and tolerance on measured (mm, %) value. d) Thickness of outer sheath and tolerance on measured (mm, %) values. 9 Armour a) Material b) Shape c) Dimension (mm) 10 a) Overall diameter of cable (mm) b) Tolerance on diameter (%) 11 a) Minimum tensile strength of insulation (kg/sq. cm) b) Minimum elongation at break. (%) 12 a) Minimum tensile strength of sheath. (kg/sq. cm) b) Minimum elongation at break (%) 13 a) Tensile strength of the armour b) Elongation after break 14 High voltage test and duration (PVC cables) a) At room temperature b) Under water 15 XLPE cable a) High voltage test b) Short circuit current rating for 1 sec. c) Short circuit current rating for armour a) Current carrying capacity in air and corresponding assumptions/conditions of installation (kg/sq. cm) (%) (kV, mins.) (kV, mins.) (kV, mins.) (kA) (kA, Secs) (Amp)

16

-103Section - IX : Guaranteed & other Technical Particulars

D.
Sl. No.

POWER AND CONTROL CABLE - XLPE CABLE Description


b) Current carrying capacity under following conditions: i) Ambient temperature of 38 Deg. C ii) Cable laid in covered cable trenches iii) 3 to 4 cable trays / racks in trench . iv) 5 to 6 cables per tray and touching each other. Insulation resistance at 27 Deg. C Capacitive reactance per Km. Inductive reactance per Km. Minimum bending radius. Short circuit current rating for 1 sec. Conductor temperature rise during Normal operation Short circuit Weight of cable per Km a) Standard length of cable per drum b) Tolerance on length of cable per drum Net weight of drum length of cable Method of core identification for Cable upto five cores Cable with more than five cores Please indicate writing YES or NO whether the following tests have been carried out. i) Ageing test ii) Loss of mass test iii) Cold bend test iv) Cold impact test v) Heat shock test vi) Thermal stability as per IEC-540 vii) Oxygen index test and temperature index test as per ASTM D-2863. viii) Rodent and termite proof test ix) Fire retardant test Enclosures Whether all type test reports enclosed Whether technical literature enclosed Whether tables giving rating factors for variation in standard conditions of installation enclosed Whether relevant drawings enclosed (Amp) (Amp) (Amp) (Amp) (Ohm/km) (Ohm/km) (Ohm/km) (mm) (kA) (Deg. C) (Deg. C) (Kg/km)\ (m) (%) (Kg) Unit 3Cx300 3.5Cx240

17 18 19 20 21 22 a) b) 23 24 25 26 a) b) 27

(Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

28 a) b) c) d)

-104Section - IX : Guaranteed & other Technical Particulars

D.

POWER AND CONTROL CABLE - POWER CABLE


4Cx16 4Cx6 2Cx6

Unit 3.5Cx70 3.5Cx35 Sl. No. Description 1 Name of the manufacturer and country. 2 Applicable standard 3 Cable type designation (Volts) 4 Voltage rating 5 Conductor a) Material of conductor and flexibility class as per IS:8130 (sq. mm) b) Size of conductor (Yes/No) c) Is conductor stranded d) Stranded conductor i) Number of strands in each core (sq. mm) ii) Size of strand iii) Shape of the stranded conductor iv) Maximum DC resistance at (Ohms) / Km 20 deg C 6 Number of cores 7 Insulation a) Insulation material and type designation (mm) b) Minimum thickness of (%) c) Tolerance on the measured value of thickness d) Minimum volume resistivity at (Ohm-cm) 27 deg. C, 70 deg. C and 90 8 Sheath

Section - IX : Guaranteed & other Technical Particulars

-105-

D.

POWER AND CONTROL CABLE - POWER CABLE


Unit 3.5Cx70 3.5Cx35 4Cx16 4Cx6 2Cx6

Sl. No. Description a) Material for inner sheath, type of sheathing (extruded or wrapped) and type designation as per IS:5831. b) Material for outer sheath, type of sheathing (extruded or wrapped) and type designation as per IS:5831. c) Thickness of inner sheath and tolerance on measured value. d) Thickness of outer sheath and tolerance on measured values. 9 Armour a) Material b) Shape c) Dimension 10 a) Overall diameter of cable b) Tolerance on diameter 11 a) Minimum tensile strength of insulation b) Minimum elongation at 12 a) Minimum tensile strength of sheath. b) Minimum elongation at break 13 a) Tensile strength of the b) Elongation after break

(mm, %) (mm, %)

(mm) (mm) (%) (kg/sq. cm) (%) (kg/sq. cm) (%) (kg/sq. cm) (%)

Section - IX : Guaranteed & other Technical Particulars

-106-

D.

POWER AND CONTROL CABLE - POWER CABLE


Unit 3.5Cx70 3.5Cx35 4Cx16 4Cx6 2Cx6

Sl. No. Description 14 High voltage test and duration (PVC cables) a) At room temperature b) Under water 15

(kV, mins.) (kV, mins.)

XLPE cable (kV, mins.) a) High voltage test (kA, Secs) b) Short circuit current rating c) Short circuit current rating for (kA, Secs) armour (Amp) 16 a) Current carrying capacity in air and corresponding assumptions/conditions of installation b) Current carrying capacity under following conditions: (Amp) i) Ambient temperature of 50 Deg. C (Amp) ii) Cable laid in covered cable trenches (Amp) iii) 3 to 4 cable trays / racks in trench . (Amp) iv) 5 to 6 cables per tray and touching each other. 17 Insulation resistance at 27 Deg. (Ohm/km) (Ohm/km) 18 Capacitive reactance per Km. (Ohm/km) 19 Inductive reactance per Km. (mm) 20 Minimum bending radius.

Section - IX : Guaranteed & other Technical Particulars

-107-

D.

POWER AND CONTROL CABLE - POWER CABLE


Unit (kA) 3.5Cx70 3.5Cx35 4Cx16 4Cx6 2Cx6

Sl. No. Description 21 Short circuit current rating for 1 sec. for PVC cable. 22 Conductor temperature rise a) during Normal operation b) Short circuit 23 Weight of cable per Km 24 a) Standard length of cable per drum b) Tolerance on length of cable per drum 25 Net weight of drum length of cable (approx.) 26 Method of core identification a) Cable upto five cores b) Cable with more than five cores 27 Please indicate writing YES or NO whether the following tests have been carried out. i) Ageing test ii) Loss of mass test iii) Cold bend test iv) Cold impact test v) Heat shock test vi) Thermal stability as per IEC540

(Deg. C) (Deg. C) (Kg/km)\ (m) (%) (Kg)

(Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

Section - IX : Guaranteed & other Technical Particulars

-108-

D. Sl. No.

POWER AND CONTROL CABLE - POWER CABLE Description vii) Oxygen index test and temperature index test as per ASTM D-2863. viii) Rodent and termite proof ix) Fire retardant test Enclosures Whether all type test reports enclosed Whether technical literature enclosed Whether tables giving rating factors for variation in standard conditions of installation Whether relevant drawings enclosed
Unit (Yes/No) 3.5Cx70 3.5Cx35 4Cx16 4Cx6 2Cx6

(Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

28 a) b) c)

d)

(Yes/No)

Section - IX : Guaranteed & other Technical Particulars

-109-

POWER AND CONTROL CABLE - CONTROL CABLE D. Unit 2Cx2.5 5Cx2.5 7Cx2.5 10Cx2.5 14Cx2.5 Sl. No. Description 1 Name of the manufacturer and country. 2 Applicable standard 3 Cable type designation (Volts) 4 Voltage rating 5 Conductor a) Material of conductor and flexibility class as per IS:8130 (sq. mm) b) Size of conductor (Yes/No) c) Is conductor stranded d) Stranded conductor i) Number of strands in each core (Before stranding) (sq. mm) ii) Size of strand iii) Shape of the stranded conductor iv) Maximum DC resistance at (Ohms/ Km) 20 deg C 6 Number of cores 7 Insulation a) Insulation material and type designation (mm) b) Minimum thickness of (%) c) Tolerance on the measured value of thickness d) Minimum volume resistivity at (Ohm-cm) 27 deg. C, 70 deg. C and 90 deg. 8 Sheath

19Cx2.5

27Cx2.5

-110Section - IX : Guaranteed & other Technical Particulars

POWER AND CONTROL CABLE - CONTROL CABLE D. Unit 2Cx2.5 5Cx2.5 7Cx2.5 10Cx2.5 14Cx2.5 Sl. No. Description a) Material for inner sheath, type of sheathing (extruded or wrapped) and type designation as per IS:5831. b) Material for outer sheath, type of sheathing (extruded or wrapped) and type designation as per IS:5831. (mm, %) c) Thickness of inner sheath and tolerance on measured value. (mm, %) d) Thickness of outer sheath and tolerance on measured values. 9 Armour a) Material b) Shape (mm) c) Dimension (mm) 10 a) Overall diameter of cable (%) b) Tolerance on diameter 11 a) Minimum tensile strength of (kg/sq. cm) insulation (%) b) Minimum elongation at 12 a) Minimum tensile strength of (kg/sq. cm) sheath. (%) b) Minimum elongation at break (kg/sq. cm) 13 a) Tensile strength of the (%) b) Elongation after break 14 High voltage test and duration (PVC cables)

19Cx2.5

27Cx2.5

-111Section - IX : Guaranteed & other Technical Particulars

D. Sl. No. a) b) 15 a) b) c) 16

POWER AND CONTROL CABLE - CONTROL CABLE Description At room temperature Under water XLPE cable High voltage test Short circuit current rating Short circuit current rating for armour a) Current carrying capacity in air and corresponding assumptions/conditions of installation b) Current carrying capacity under following conditions: i) Ambient temperature of 50 Deg. C ii) Cable laid in covered cable trenches iii) 3 to 4 cable trays / racks in trench . iv) 5 to 6 cables per tray and touching each other. Insulation resistance at 27 Deg. Capacitive reactance per Km. Inductive reactance per Km. Minimum bending radius. Short circuit current rating for 1 sec. for PVC cable. Conductor temperature rise during
Unit (kV, mins.) (kV, mins.) (kV, mins.) (kA, Secs) (kA, Secs) (Amp) 2Cx2.5 5Cx2.5 7Cx2.5 10Cx2.5 14Cx2.5 19Cx2.5 27Cx2.5

(Amp) (Amp) (Amp) (Amp) (Ohm/km) (uF/km) (Ohm/km) (mm) (kA)

17 18 19 20 21 22

-112Section - IX : Guaranteed & other Technical Particulars

D. Sl. No. a) b) 23 24

POWER AND CONTROL CABLE - CONTROL CABLE


Unit (Deg. C) (Deg. C) (Kg/km)\ (m) (%) (Kg) 2Cx2.5 5Cx2.5 7Cx2.5 10Cx2.5 14Cx2.5 19Cx2.5 27Cx2.5

Description Normal operation Short circuit Weight of cable per Km a) Standard length of cable per drum b) Tolerance on length of cable per drum 25 Net weight of drum length of cable of core identification 26 Method a) Cable upto five cores b) Cable with more than five cores 27 Please indicate writing YES or NO whether the following tests have been carried out. i) Ageing test ii) Loss of mass test iii) Cold bend test iv) Cold impact test v) Heat shock test vi) Thermal stability as per IEC540 vii) Oxygen index test and temperature index test as per ASTM D-2863. viii) Rodent and termite proof ix) Fire retardant test 28 Enclosures

(Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

(Yes/No) (Yes/No)

-113Section - IX : Guaranteed & other Technical Particulars

POWER AND CONTROL CABLE - CONTROL CABLE D. Unit 2Cx2.5 5Cx2.5 7Cx2.5 10Cx2.5 14Cx2.5 Sl. No. Description (Yes/No) a) Whether all type test reports enclosed (Yes/No) b) Whether technical literature enclosed (Yes/No) c) Whether tables giving rating factors for variation in standard conditions of installation (Yes/No) d) Whether relevant drawings enclosed

19Cx2.5

27Cx2.5

-114Section - IX : Guaranteed & other Technical Particulars

E. STRUCTURE Sl. Description No. A SUBSTATION STRUCTURE 1 Total Guaranteed Weight of Structure in Metric Tonnes a) Columns (Each type separately) b) Beams (Each type separately) 2 Maximum stress employed in design a) Tension in net sectional area b) Compression on gross sectional area at maximum slenderness ratio c) Shearing stress on steel bolts d) Bearing stress on steel bolts 3 Other Particulars a) Maximum Slenderness Ratio i) Main leg members of columns ii) Main boom members of beam iii) Lattice members having calculated stress iv) Redundant members having nominal stress v) Members under tensions only vi) Strut formula used b) Standards according to which properties of sections have been adopted c) Standard specification to which quality of steel for the sections would conform and technical properties of the type of steel offered. d) Standard to which galvanising shall conform e) Minimum sheared edge distances f) Minimum rolled edge distance g) Quality of zinc used for galvanising h) Weight of zinc coating per MT of structure weight and min. thickness of zinc coating i) Sizes of bolts and bolt holes j) Standard to which bolt and nuts conforms k) Name of manufacturer of bolts and nuts 4 Factor of Safety a) Normal condition b) Abnormal condition of broken wire B EQUIPMENT SUPPORT STRUCTURE 1 Circuit Breaker a) Type (Lattice / Pipe) b) Guaranteed weight c) Factor of Safety i) Normal Condition ii) Abnormal Condition d) Weight of zinc coating per MT of structure weight and min. thickness of zinc coating e) Size of bolts & bolt holes 2 Current Transformer a) Type (Lattice / Pipe) -115Section - IX : Guaranteed & other Technical Particulars

Unit

Guaranteed Particulars 132 KV 33 KV

(MT) (MT) (N/sq. mm) (N/sq. mm) (N/sq. mm) (N/sq. mm)

(mm) (mm) (%) (gm/MT, gm/sq. m) (mm)

MT

(gm/MT, gm/sq. m) (mm)

Sl. Description No. b) Guaranteed weight c) Factor of Safety i) Normal Condition ii) Abnormal Condition d) Weight of zinc coating per MT of structure weight and min. thickness of zinc coating e) Size of bolts & bolt holes 3 Isolator Structure 3 Pole a) Type (Lattice / Pipe) b) Guaranteed weight c) Factor of Safety i) Normal Condition ii) Abnormal Condition d) Weight of zinc coating per MT of structure weight and min. thickness of zinc coating e) Size of bolts & bolt holes Isolator Structure 1 Pole a) Type (Lattice / Pipe) b) Guaranteed weight Guaranteed weight ( for 2 Pole Isolator ) c) Factor of Safety i) Normal Condition ii) Abnormal Condition d) Weight of zinc coating per MT of structure weight and min. thickness of zinc coating e) Size of bolts & bolt holes CVT a) Type (Lattice / Pipe) b) Guaranteed weight c) Factor of Safety i) Normal Condition ii) Abnormal Condition d) Weight of zinc coating per MT of structure weight and min. thickness of zinc coating e) Size of bolts & bolt holes Post Insulator a) Type (Lattice / Pipe) b) Guaranteed weight c) Factor of Safety i) Normal Condition ii) Abnormal Condition d) Weight of zinc coating per MT of structure weight and min. thickness of zinc coating e) Size of bolts & bolt holes

Unit MT

Guaranteed Particulars

(gm/MT, gm/sq. m) (mm)

MT

(gm/MT, gm/sq. m) (mm)

MT MT

(gm/MT, gm/sq. m) (mm)

MT

(gm/MT, gm/sq. m) (mm)

MT

(gm/MT, gm/sq. m) (mm)

-116Section - IX : Guaranteed & other Technical Particulars

Sl. No. 7 a) b) c)

Description

Unit

Guaranteed Particulars

Surge Arrestor Type (Lattice / Pipe) Guaranteed weight Factor of Safety i) Normal Condition ii) Abnormal Condition d) Weight of zinc coating per MT of structure weight and min. thickness of zinc coating e) Size of bolts & bolt holes Potential Transformer a) Type (Lattice / Pipe) b) Guaranteed weight c) Factor of Safety i) Normal Condition ii) Abnormal Condition d) Weight of zinc coating per MT of structure weight and min. thickness of zinc coating e) Size of bolts & bolt holes

MT

(gm/MT, gm/sq. m) (mm)

MT

(gm/MT, gm/sq. m) (mm)

-117Section - IX : Guaranteed & other Technical Particulars

LIGHTING SYSTEM Sl. No. Description (i)Lighting fixtures & Accessories 1 Manufacturer's Name and Address a) Fixtures b) Accessories 2 Applicable standards for a) Fixtures b) Accessories 3 Manufacturer's type and catalogue no. for a) Fixtures b) Accessories 4 5 a) b) 6 7 8 9 10 11
(Volts) Nominal working voltage Maximum permissible supply voltage variation for satisfactory operation of (+ %) Fixtures (+ %) Accessories Power factor at nominal working voltage and frequency (Amps) Full load output current at nominal working voltage (Watts) Power loss per ballast at nominal working voltage & frequency Maximum hot spot temperatures of ballast (Deg. C) case (Deg. C) Maximum average ballast winding temperature (Deg. C) Ambient temperature within the fitting in continuous operation at the design ambient air temperature Insulation class of ballast winding Average life expectancy of (hours) Ballast (hours) Capacitors (hours) Lamps Lamp output at the design temperature (Lumens) After 100 burning hours (Lumens) After 1000 burning hours Lamp output at the end of the expected life (Lumens) period

Unit

Guaranteed Particulars

12 13 a) b) c) 14 a) b) 15

-118Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 16 Average light output of the fitting as a percentage of lamp output. a) Downwards b) Upwards 17 Beam angle for flood lights in a) Horizontal plane b) Vertical plane 18 a) Cable/conduit entry size b) Size and type of cable 19 Earthing terminal a) Material b) Suitable for earthing conductor of size 20 Weights of fixtures 21 Starting current & PF for lamp 22 Operating current 23 Time vs Mains current & PF characteristics during starting enclosed 24 Reference catalogue No. (ii) Receptacles with Switches 1 2 3 4 a) b) 5 6 1 2 3 4 a) b) 5 6 1 2 3 4

Unit

Guaranteed Particulars

(%) (%) (Degrees) (Degrees) (mm) (sq. mm)

(mm x mm) (Kg) (Amps) (Amps) (Yes/No)

Manufacturer's Name and Address Manufacturer's type designation. (Volts) Voltage grade Current rating at specified ambient temperature of 38 Degrees C (Amps) Make and carry (Amps) Break Applicable standards Whether descriptive pamphlet is enclosed? (Yes/No) (iii) Lighting control switches Manufacturer's Name and Address Manufacturer's type designation (Volts) Voltage grade Current rating at specified ambient temperature of 38 Deg. C (Amps) Make and carry (Amps) Break Applicable standards Whether descriptive pamphlet is enclosed? (Yes/No) (iv) Conduits & Accessories Manufacturer's Name and Address Manufacturer's type designation. Applicable standards Whether descriptive pamphlet is enclosed? (Yes / No)

-119Section - IX : Guaranteed & other Technical Particulars

Sl. No. 1 2 3 4 5 a) b) c) d) e) 6 1 2 3 4 5

Description (v) Junction Boxes Manufacturer's Name and Address Manufacturer's type designation. Material specification Type of enclosure Terminals Make Current rating Voltage rating Stud type Complete with insulated barriers Whether descriptive pamphlet is enclosed? (vi) Pull out Boxes Manufacturer's Name and Address Manufacturer's type designation. Material specification Type of enclosure Whether descriptive pamphlet is enclosed (vii) Lighting Panels (a) General Manufacturer's Name and Address

Unit

Guaranteed Particulars

(Amp) (Volts) (Yes/No) (Yes/No) (Yes/No)

(Yes/No)

1 2 3 4 5

Indoor/outdoor application Design ambient air temperature Thickness of sheet steel Degree of protection provided (as per IS: 13947 or equivalent) 6 Bill of material for various equipment 7 Colour of finish paint i) Outside ii) Inside 8 Busbars i) Material ii) Temperature rise at rated current over iii) Continuous current rating at 38 deg. C ambient temperature iv) Whether suitable for one second current rating of 20 kA (AC) or 5 kA (DC) as applicable v) Cross section vi) Applicable standard

(Deg. C) (mm)

(Yes/No)

(Deg. C) (Amp) (Yes/No)

-120Section - IX : Guaranteed & other Technical Particulars

Sl. No. 9 i) ii) 10 11 i) ii)

Description

Unit

Guaranteed Particulars

12

1 2 3 4 5 6 7

Control wiring Material of conductor (mm) Size of conductor/dia of wire Conductor (Solid / Stranded.) Terminal blocks Make Current Rating (Amp) (a) Power terminal (Amp) (b) Other terminal All tests as specified in specifications will (Yes/No) be carried out. (b) Air Break Switches (if applicable) Manufacturer's Name and Address Manufacturer's type description Applicable standard (Volts, Hz) Rated voltage & frequency Rated current Rated breaking current Maximum through fault current withstand, derating factor for use under site ambient conditions Temperature rise of contacts when carrying continuous rated current under site conditions. (c) Fuses Manufacturer's Name and Address Manufacturer's type designation Applicable standard Rated voltage Rated current Whether fuse is mounted in an insulated carrier Whether fuse carrier has an aperture for fuse failure indication. Category of duty (IS:2208) Rupturing capacities (Prospective current) Maximum let through current for 1 sec. Whether time/current characteristics are enclosed? (d) Miniature circuit breaker Manufacturer's Name and Address Type Rated voltage No. of poles Frequency Current rating a) Continuous at 38 Deg. C ambient temperature b) 1 sec.
(Amps) (Amps) (Amps)

(Deg. C)

1 2 3 4 5 6 7 8 9 10 11

(Volts) (Amp) (Yes/No) (Yes/No)

(kA) (kA) (Yes/No)

1 2 3 4 5 6

(Volts) (Nos.) (Hz) (Amp) (Amp) (kA rms)

-121Section - IX : Guaranteed & other Technical Particulars

Sl. Description Unit No. 7 Breaking capacity for Single Phase / Double Pole / Triple Pole a) Symmetrical (kA rms at volt) b) Asymmetrical(kA rms at volt) (Cycle) 8 Total interrupting time 9 Type of blow out device 10 Type of overload (terminal/magnetic) (sq. mm) 11 Terminal suitable for cable size (kA) 12 Upto what fault current discrimination between incomer fuse & MCB will be obtained? 13 Standards to which Miniature Circuit Breaker conforms (e) Contactors (For each type DC/AC) 1 Manufacturer's Name and Address (Volts, %) 2 Rated voltage & permissible variation 3 4 5 6 7 8 9 10 Rated burden Rated current (thermal) of main contacts No. & type of Aux. Contacts (if any) Rated voltage of coil Pick up voltage Rated duty class Drop off voltage Applicable standard (f) Emergency portable lighting fixture Manufacturer's Name and Address Applicable standards Manufacturer's type & catalogue no. Nominal working voltage Rated duration for providing useful luminous output Lamp wattage Battery capacity Battery voltage Bulb voltage Whether rectifier circuits are solid state Type of charging device used Time interval required for charging Whether tropicalised Weight of unit without batteries Weight of battery Make of battery Expected life of fixture Whether descriptive pamphlets are enclosed? (g) Street Lighting Poles Manufacturer's Name and Address Manufacturer's type designation Applicable standard
(VA) (Amp) (Volts) (Volts) (Volts)

Guaranteed Particulars

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 1 2 3

(Volts) (hours) (Watts) (AH) (Volts) (Volts) (Yes/No) (hours) (Yes/No) (Kg) (Kg) (hours) (Yes/No)

-122Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 4 Dimensions 5 Whether sketch and descriptive pamphlet is enclosed? (h) Lighting Wires 1 Manufacturer's Name and Address 2 Standard applicable 3 Rated voltage 4 Continuous current rating when laid in conduit in ambient condition 5 Conductor a) Material b) Nominal cross sectional area c) Number & diameter of wires 6 a) b) c) d) 7 8 1 2 3 4

Unit
(Yes/No)

Guaranteed Particulars

(Volts) (Amp)

(sq. mm) (Nos. / mm)

1 a) b) c) 2 a) b) 3

Insulation Composition of insulation (mm) Thickness of insulation (%) Tolerance on thickness of insulation Specific insulation resistance at 60C Colour scheme for identification of wires (Yes/No) Whether descriptive pamphlet is (i) Ladders Manufacturer's Name and Address Manufacturer's type designation Applicable standard Whether drawing and descriptive pamphlet (Yes/No) is enclosed. (j) Painting Paints (for each type) Manufacturer's Name and Address Manufacturer's type designation/brand Shade. Number of coats provided for (Nos.) Lighting poles & other fabricated steel (Nos.) Junction boxes Applicable standards

-123Section - IX : Guaranteed & other Technical Particulars

Sl. No. 1 a) b) c) d) e) f) g) h) i) j) k)

Description (k) Ceiling fan and regulator Ceiling fan Manufacturer's Name and Address Manufacturer's type designation Applicable standard Material of the winding Class of insulation Temperature rise above ambient Maximum and minimum speed (with regulator) Rated voltage Rated frequency Power factor Air delivery at test voltage

Unit

Guaranteed Particulars

(Deg. C) (RPM) (Volts) (Hz) (m3 / min/W) (m3 / min/W) (Yes/No)

l) Service value at rated voltage m) n) 2 a) b) c) d) e) f) g) h) Number of blades Whether descriptive pamphlet is enclosed? Fan Regulator Manufacturer's Name and Address Manufacturer's type designation/brand name Applicable standard Type of regulator Smooth control or step control If step controlled, no. of steps provided to control the speed Power loss in regulator Whether descriptive pamphlet is enclosed.

(Watts) (Yes/No)

-124Section - IX : Guaranteed & other Technical Particulars

G. DIESEL GENERATOR SET Sl. Description No. (a) GENERAL 1 Bidders Name and Address 2 Manufactures Name, type, model and address for a) Diesel Engine along with accessories b) Alternator c) Exciter d) Battery e) Battery charger f) DG control panel for site condition (b) ENGINE 1 Rating a) Manufacturers Rating b) At site condition 2 Revolutions per minute 3 Number and arrangement of cylinders, cylinder box and stroke 4 Method of starting 5 Time required for starting from cold conditions 6 Auxiliary power consumption 7 a) Type of Governor

Unit

Guaranteed Particulars

(kVA) (kVA) (RPM) (mm)

(Sec) (kW)

b) Relevant standard c) Confirm portions of mechanical over speed tripping at 110% d) Class of governor 8 Guaranteed limits of governing a) Permanent variation i) Full load thrown off ii) Full load put on b) Temporary variation i) Full load thrown off ii) Full load put on c) Fuel injection i) at full load ii) at no load d) Fly wheel details (mm) i) Diameter (mm) ii) Width of rim (Kg) iii) Weight (mm) iv) Thickness of rim (RPM) 9 Rated RPM (%) 10 Total speed variation 11 Specification of fuel oil 12 Specification of lube oil 13 Guaranteed fuel consumption (ml/kWh) a) At full load (ml/kWh) b) At 3/4 load (ml/kWh) c) At 1/2 load

-125Section - IX : Guaranteed & other Technical Particulars

Sl. No. d) e) f) g) h) 14 15 16 17 18 19 20 21 22

Description

Unit

Guaranteed Particulars

(ml/kWh) At 1/4 load (ml/kWh) Specific fuel consumption Compression ratio (kg/sq. mm) Compression pressure (kg/sq. mm) Maximum cylinder pressure (ml/kWh) Lubricating oil consumption (litres) Capacity of fuel tank (%) Mechanical efficiency (%) Thermal efficiency Cyclic variation (Yes/No) Safety protection provided Direction of rotation Method of aspiration Method of cooling of engine and lubrication oil (litres) 23 Amount of water required for cooling system (Kg) 24 Total weight

25 Space requirement including clearance 26 Makers name type and technical particulars for 27 Air-Filter-Cum-Silencer a) Rated capacity b) Clear area c) Maximum particle size removed 28 Coupling a) Type of flexible coupling provided & length b) Shaft sealing arrangement 29 Piping and fitting a) Material b) Design pressure c) Temperature rise d) Applicable standard 30 Thermometers a) Type b) Manufacturers name c) Least count d) Range e) Accuracy f) Number supplied 31 Pressure Gauges a) Type b) Manufacturers name c) Least count d) Range e) Accuracy f) Location g) Dial size h) Number supplied 32 Level indicator -126Section - IX : Guaranteed & other Technical Particulars

(m x m x m)

(mm) (mm) (m)

(kg/sq. mm) (Deg. C)

(Deg. C) (Deg. C) (%)

(kg/sq. mm) (kg/sq. mm) (%) (mm x mm) (Nos.)

Sl. No. a) b) c) d) e) 33 a) b) c) d) e) 34

Description

Unit

Guaranteed Particulars

Type Manufacturers name Range Location Number supplied Tachometer Type Manufacturers name Reduction ratio Range Accuracy Mechanical auxiliary loads connected on main shaft with rating 35 Any hand barring gear provided 36 Permissible voltage range (c) STORAGE TANK 1 Type and shape 2 Capacity 3 Number supplied 4 Material of construction 5 Overall dimensions 6 7 8 Overall internal dimensions Plate thickness Design pressure and temperature

(Nos.)

(%) (kW) (Yes/No) (Volts, %)

(litres) (Nos.) (mm x mm x mm) (mm x mm x mm) (mm) (kg/sq. mm, Deg. C) (Kg) (Yes/No)

9 Type of welding and joints 10 Weight of completely fabricated tank including all supports and fittings 11 Whether hand pump and accessories supplied. (d) ALTERNATOR 1 Type 2 Manufacturers name 3 4 5 6 7 8 9 10 11 12 a) b) c) 13 Rated kW capacity Rated kVA capacity Type of insulation Rated terminal voltage Rated power factor Rated stator current Rated speed Rated frequency Excitation current and voltage at rated power output and power factor Efficiency at rated power factor at Full load 3/4 load 1/2 load Efficiencies and power factor at the following values of full load -127Section - IX : Guaranteed & other Technical Particulars

(kW) (kVA)

(Volts) (Amp) (RPM) (Hz) (Amp, Volts) (%) (%) (%)

Sl. No. a) b) c) d) e) 14 15 16 17 a) b) c) d) e) f) g) h) i) 18 19 a) b) c) d) e) 20 a) b) c) d) e) f) g) 21 a) b) c) d) e) f) g) 22 23 24

Description 110% 100% 75% 50% 25% Inherent voltage regulation Are damper windings fitted Air gap between starter and rotor Percentage impedance Xd" saturated Xd" unsaturated Xd" (Sub transient reactance) Xd (Synchronous reactance) X0 (Zero sequence reactance) X2 (Negative sequence reactance) Open circuit field time constant Short Circuit Ratio Resistance of field winding at operating temperature Transient resistances Generator performance Full load losses Armature copper losses Rotor copper loss Core loss Stray losses Exciter Type of excitation system Continuous capacity Short time capacity Continuous voltage Short time voltage Weight of exciter excluding foundation Applicable standard Automatic voltage Regulator Manufacturers name & address Type Time constant Sensitivity from no load to full load Setting provided Characteristic curve for AVR furnished Applicable standard Class of insulation Total weight Applicable standards

Unit (%, pf) (%, pf) (%, pf) (%, pf) (%, pf) (%) (Yes/No) (mm) (Ohms, %) (Ohms, %) (Ohms, %) (Ohms, %) (Ohms, %) (Ohms, %)

Guaranteed Particulars

(Ohms) (%) (kW) (kW) (kW) (kW) (kW)

(Volts) (Volts) (Kg)

(%) (Yes/No)

(Kg)

25 Peripheral speed of the rotor 26 Critical speed of the rotor 27 Direction of rotation

(RPM) (RPM)

-128Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 28 Method of lubrication 29 Method of cooling 30 Maximum temperature rise of stator core over ambient temperature 31 Electrical auxiliary loads connected to generator terminals with rating 32 Alternator parameters (e) ENGINE ALTERNATOR SET 1 Starting time 2 Interval between starting impulse 3 4 1 2 3 4 5 6 7 8 No. of starting impulses Time for picking up the full load (f) CONTROL PANEL / BOARD Manufacturers name and address Sheet steel thickness Method of vermin proofing and making dust proof Outline dimensions (LxWxH) Weight Type of mounting Cable termination details Door with locking arrangement provided

Unit

Guaranteed Particulars

(Deg. C) (kW)

(Sec) (Sec)

(Sec)

(mm)

(mm x mm x mm) (Kg)

(Yes/No)

9 Colour shade as per IS:5 10 Degree of protection 11 Make, type, technical specification and catalogues for each type of component to be mounted in control panel enclosed 12 Current Transformers a) Type and make b) Rated transformation ratio c) Rated output d) Class of accuracy e) Accuracy Limit Factor f) g) h) i) 13 a) b) c) d) e) f) Applicable standard Instrument Security Factor Short time thermal current rating Rated continuous thermal current Wiring Voltage grade Insulation Conductor material Size of conductor No. of conductors Maximum current rating

(Yes/No)

(VA)

(Amp, Sec) (Amp) (Volts)

(sq. mm) (Nos.) (Amp)

-129Section - IX : Guaranteed & other Technical Particulars

Sl. No. g) h) i) j) 14 a) b) c) d) e)

Description Colour code used Type of terminals Size of terminals Applicable standards Indicating Instruments Make and type Size Scale size Accuracy class VA burden i) Current coil ii) Voltage coil Relevant catalogue enclosed Angle of deflection Scale length Current coil rating Voltage coil rating (g) BATTERY CHARGER Manufacturers name and address Type of rectifier Rated output current Output voltage range Applicable standards, complete technical specification & literature furnished Type of circuit Rated AC input voltage with percentage permissible variation (h) BATTERY Type Name of manufacturer and address No. of cells Capacity in AH at 10 hour rate Current Capacity of Full charged battery Fully discharged battery Average life in years Applicable standard Weight of the battery Overall dimensions of each cell

Unit

Guaranteed Particulars

(sq. mm)

(mm x mm) (Degrees)

(VA) (VA) (Yes/No) (Degrees) (mm) (Amp) (Volts)

f) g) h) i) j) 1 2 3 4 5 6 7

(Amp) (Volts) (Yes/No)

(Volts, %)

1 2 3 4 5 a) b) 6 7 8 9

(Nos.) (AH) (Amp) (Amp) (Years) (Kg) (mm x mm x mm)

10 Rated specific gravity of electrolyte when fully charged at the room temperature of 27 deg. C 11 Rated specific gravity of electrolyte when fully discharged at the room temperature of 27 deg. C 12 Charging current of the battery 13 Voltage of each battery cell during a) Full charge b) Floating condition

(Amp) (Volts) (Volts)

-130Section - IX : Guaranteed & other Technical Particulars

Sl. No. 1 2 3 4 5 6 7 8 9

Description (i) PROTECTIVE RELAYS Make Type Coil rating Setting range Burden Reset ratio Characteristic of time vs current enclosed Descriptive pamphlet enclosed Applicable standard (j) EQUIPMENT MOUNTED The complete list of flush mounted and other equipment mounted inside the control panel with quantity against each is to be furnished by the tenderer with the tenders. (k) WEIGHT SCHEDULE Weight of engine less fly wheel including standard accessories Weight of fly wheel Weight of generator Weight of exciter Weight of control panel Weight of sub-base Total equipment weight Heaviest single piece to be handled during erection and maintenance and its weight.

Unit

Guaranteed Particulars

(V, A, AC/DC) (VA) (Yes/No) (Yes/No)

1 2 3 4 5 6 7 8

(Kg) (Kg) (Kg) (Kg) (Kg) (Kg) (Kg) (Kg)

-131Section - IX : Guaranteed & other Technical Particulars

H Sl. No. (a)

FIRE FIGHTING EQUIPMENT Description Fire Water Pumps / Jockey Pumps


Unit

Guaranteed Particulars HYDRANT Motor Engine Driven SPRAY Motor Engine Driven JOCKEY

Manufacturer Type & model No. Number of pumps Number of stages Capacity of pumps a) Rated capacity b) Min. capacity at which the pump may run continuously c) Max. capacity at which the pump can run continuously. 6 Total dynamic head a) At rated capacity b) At 150% of rated capacity c) At shut off 7 Max. section lift the pump can accept a) At rated capacity b) At max. capacity 8 NPSH required 9 Power consumed by the pump at a) Rated max. condition b) Shut off condition 10 Rating of the drive motor provided 11 Efficiency at rated capacity

1 2 3 4 5

(Nos.) (Nos.) (m3/hr) (m3/hr) (m3/hr)

(mwc) (mwc) (mwc) (mwc) (mwc) (mwc) (kW) (kW) (kW) (%)

-132Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 12 Speed 13 Specific speed = (3.65 NQ1/2)/H3/4 where N= Speed Q= Capacity in m3/sec H= Head per stage, m 14 15 16 17 Size of suction Size of discharge Diameter of impeller Material of construction a) Pump casing b) Impeller c) Pump shaft d) Shaft sleeve e) Wear rings f) Stuffing box g) Coupling h) Gland packing i) Base Plate j) Sole plate Radial bearing a) Type b) Numbers c) Location Thrust bearing a) Type b) Numbers c) Location Method of balancing axial/thrust Lubrication particulars

Unit (RPM)

Guaranteed Particulars

(mm) (mm) (mm)

18

(Nos.)

19

(Nos.)

20 21

-133Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 22 Internal bypass for maintaining minimum flow 23 Coupling a) Type-direct/flexible b) Manufacturer c) Coupling guard provided 24 Base plates, sole plates, lifting lugs and eye bolts, foundation anchor bolts supplied 25 Pressure switch provided 26 Pressure gauges at suction and delivery provided 27 Air release valves and drain plug etc. provided 28 Performance testing of the pumps possible at manufacturers work. 29 Standard applicable for pumps 30 Pumps suitable for parallel operation 31 Pumps suitable for service proposed 32 Pumps & drives approved by TAC 33 Weight a) Weight of pump b) Weight of the motor c)Weight of heaviest piece to be handled during erection and maintenance 34 Lifting arrangement 35 Illustrative leaflets attached (b) Sump Pump 1 Manufacturer 2 Type & model No.

Unit (Yes/No)

Guaranteed Particulars

(Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

(Yes/No) (Yes/No) (Yes/No) (Kg) (Kg) (Kg)

(Yes/No)

-134Section - IX : Guaranteed & other Technical Particulars

Sl. No. 3 4 5 6 7 8 9 10 11 12 13

Description

Unit (Nos.) (Nos.) (m3/hr) (mwc) (RPM) (kW) (mwc) (%) (Deg. C)

Guaranteed Particulars

Number of pumps Number of stages Guaranteed Capacity Guaranteed head at guaranteed capacity Rated speed Power consumed at guaranteed capacity Head developed at rated speed and closed discharge Guaranteed efficiency at guaranteed capacity Pump axial thrust Maximum temperature of water, the pump can Material of construction a) Pump casing b) Casing wearing rings c) Impeller d) Impeller wearing rings e) Shaft f) Shaft sleeve g) Bearings h) Stuffing box i) Base plate/supporting structure j) Coupling k) Gland packing 14 Bearings a) Type of thrust bearings & method of lubrication b) Type of main pump bearings & method of lubrication c) Type of motor bearings & method of lubrication

-135Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 15 Type of flexible coupling provided 16 Type of shaft sealing 17 Weights a) Weight of pump b) Weight of the motor c) Weight of heaviest piece to be handled during erection and maintenance 18 Illustrative leaflets attached (c) DIESEL ENGINE & ACCESSORIES (i) DIESEL ENGINE 1 Manufacturers name 2 Type & model No. 3 No. of cylinders 4 Arrangement of cylinders (vertical or horizontal) 5 Cylinder bore & stroke 6 Method of starting 7 a)Rated speed b)No. of strokes per cycle 8 a) Rated H.P. b) Engine rating at site taking into account the derating factor considered c) Derating factor considered by the bidder for the following: 1. Altitude 2. Inlet air temperature 3. Humidity 4. Any other

Unit

Guaranteed Particulars

(Kg) (Kg) (Kg) (Yes/No)

(Nos.) (mm) (RPM) (Nos.) (HP)

-136Section - IX : Guaranteed & other Technical Particulars

Sl. No. 9 10 11 12 13

Description Compression ratio Compression pressure Max. cylinder pressure Method of fuel injection Fuel injection pressure a) At full load b) At no load Fly wheel details a) Diameter b) Width c) Weight d) Thickness of rim Cycle variation Time required for starting from cold Type of governor Guaranteed limits of governing a) Permanent variation 1. Full load put on 2. Full load thrown off b) Temporary variation 1. Full load put on 2. Full load thrown off Rating for site condition Total speed variation Specification of fuel oil Specification of lube oil Guaranteed fuel consumption

Unit

Guaranteed Particulars

(kg/sq. cm) (kg/sq. cm)

(kg/sq. cm) (kg/sq. cm) (mm) (mm) (Kg) (mm) (Sec)

14

15 16 17 18

(%) (%) (%) (%) (RPM)

19 20 21 22 23

-137Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars

24 25 26 27 28 29 30 31 32 33

34 35

(ml/kWh) a) At full load (ml/kWh) b) At load (ml/kWh) c) At load (ml/kWh) d) At load (litres) Lube oil consumption at rated load, 1 engine hr. (Deg. C) a) Jacket water temperature in & out (Deg. C) b) Lube oil temperature in & out (%) Mechanical Efficiency (%) Thermal Efficiency (Yes/No) Safety protection provided Direction of rotation Method of aspiration Method of cooling (Yes/No) Whether capable of operating continuously on full load at the site elevation for a period of 6 hrs. (Kg) a) Total Weight (Kg) b)Heaviest single piece to be handled during erection & maintenance and its weight (m x m x m) Space requirement Material of construction of the following: a) Engine b) Piston c) Crank case d) Crank shaft e) Connecting rod f) Fly wheel (ii) Air filter cum silencer

-138Section - IX : Guaranteed & other Technical Particulars

Sl. No. 1 2 3 4 5 6 7 1 2 1 2 3 4 1 2 3 4 5 6 1 2 3 4

Description Type Name of manufacturer Rated capacity Clear area Maximum particle size removed Back pressure after fitting the silencer Reference to descriptive literature (iii) Coupling Type of flexible coupling provided and length Shaft sealing arrangement (iv) Piping and fitting Material Design pressure Temperature rating Applicable standard (v) Thermometer Type & model No. Manufacturer Range Accuracy Least count Number supplied (vi) Pressure Gauge Type & Manufacturer Range Accuracy Least count

Unit

Guaranteed Particulars

(m3) (m2) (mm) (kg/sq. cm)

(m)

(kg/sq. cm) (Deg. C)

(Deg. C) (%) (Deg. C) (Nos.)

(kg/sq. cm) (%) (kg/sq. cm)

-139Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 5 Location 6 Dial size 7 Number supplied (vii) Level Indicator 1 Type 2 Manufacturer 3 Range 4 Location 5 Number supplied (viii) Fuel oil storage tank 1 Type and shape 2 Capacity 3 Number supplied 4 Material of construction 5 Overall external dimensions 6 7 8 Overall internal dimension Plate thickness Design pressure and temperature

Unit

Guaranteed Particulars

(mm x mm) (Nos.)

(Nos.)

(litres) (Nos.) (mm x mm x mm) (mm x mm x mm) (mm) (kg/sq. cm, Deg. C) (Kg) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

9 ix) Type of welding and joints 10 Weight of completely fabricated supports & fittings 11 Whether following accessories are provided a) A sludge and sediment trap b) A fuel level gauge c) An inspection and cleaning hole d) A filter between the fuel tank and fuel pump

-140Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description e) Means of bleeding of air in the fuel system (ix) Tachometer Manufacturer Type & model No. Reduction ratio Range Accuracy (x) Hand barring gear provided (xi) Gear Box Type Name of the Manufacturer Gear ratio Whether gear cover is in two halves Material of construction a) Gear b) Housing for gears c) Bearings Service factor for gear drive (d) AIR COMPRESSORS FOR PRESSURISED WATER TANK & DETECTOR AIR NETWORK Manufacturer Type & Model No. Number offered Number of cylinders Number of stages

Unit (Yes/No)

Guaranteed Particulars

1 2 3 4 5

(Yes/No)

1 2 3 4 5

(Yes/No) (Yes/No)

1 2 3 4 5

(Nos.) (Nos.) (Nos.)

-141Section - IX : Guaranteed & other Technical Particulars

Sl. No. 6 7 8 9 10 11 12 13 14 15 16

Description Capacity Pressure rating Provided with intercoolers Type of inter cooler, if provided Provided with after cooler Temperature of the compressed air at the entry of air receiver Shaft H.P. of the compressor Rating of the drive motor Type of drive (Direct or V-belt) Coupling guard provided Material of construction a) Air receiver b) Crank case c) Piston d) Connecting rod e) Compressor cylinder f) Crank shaft g) Fly wheel h) Valves i) Bearings Type of lubrication for bearing and sliding Air filter cum silencer Type Manufacturers Name Rated capacity Noise level with silencer

Unit (m3/hr) (kg/sq. cm) (g) (Yes/No) (Yes/No) (Deg. C) (kW) (kW) (Yes/No)

Guaranteed Particulars

17 18 a) b) c) d)

(cu. m) (dB)

-142Section - IX : Guaranteed & other Technical Particulars

Sl. No. 19 a) b) c) d)

Description

Unit

Guaranteed Particulars

e)

f)

g) h) i) j) 20

1 2 3

Air Receiver Manufacturer (Nos.) Number offered (cu. m) Capacity Dimensions (mm) i)Diameter (mm) ii)Straight length Thickness (mm) i)Shell (mm) ii)Dished ends Material of construction i)Shell ii)Dished ends (Yes/No) Provided with safety valve, pressure switch, pressure gauge etc. (kg/sq. cm) (g) Receiver design pressure (kg/sq. cm) (g) Receiver hydraulic test pressure Standard Applicable (Yes/No) Illustrative leaflets of compressor & air receiver attached (e) PRESSURISED WATER TANK Manufacturer Standard applicable for design & fabrication Capacity (cu. m) a) Overall capacity (cu. m) b) Water holding capacity (Yes/No) Is the capacity of tank adequate for ultimate capacity

-143Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 5 Dimensions a)Diameter b)Straight length 6 Thickness a)Shell b)Dished ends 7 Material of construction a)Shell b)Dished ends 8 Direction of tank centre line (horizontal/vertical) 9 Provided with safety valve, pressure gauge, water level indicator, level switch, vent & drain etc. 10 Furnished supporting structure, base plate, anchor bolts, nuts etc. 11 Design pressure 12 Hydraulic test pressure 13 Painting as described in the specification provided 14 Illustrative leaflets attached (f) BURIED WATER PIPES AND FITTINGS 1 Manufacturer 2 Material 3 4 5 6 7 Class Type of joint Applicable standard Velocity of flow of water considered Type of protective coating/painting on the outside of the piping provided

Unit

Guaranteed Particulars

(mm) (mm) (mm) (mm)

(Yes/No) (Yes/No) (kg/sq. cm) (g) (kg/sq. cm) (g) (Yes/No) (Yes/No)

(m/sec)

-144Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 8 Bill of material attached (g) OVERGROUND PIPES & FITTINGS NORMALLY FULL OF WATER 1 Manufacturer 2 Material 3 4 5 6 7 8 Class Type of joint Applicable standard Velocity of flow of water considered Type of protective coating/painting on the outside of the piping provided Bill of material attached (h) OVERGROUND PIPES NORMALLY EMPTY BUT PERIODIC CHARGE OF WATER & AIR Manufacturer Material Class Type of joint Applicable standard Velocity of flow of water considered Type of protective coating/painting on the outside of the piping provided Bill of material attached (i) GATE VALVE (AIR/WATER) Manufacturer

Unit (Yes/No)

Guaranteed Particulars

(m/sec)

(Yes/No)

1 2 3 4 5 6 7 8 1

(m/sec)

(Yes/No)

-145Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 2 Type 3 Material of construction a) Body b) Valve trim 4 Flange particulars 5 Direction of hand wheel operation to close 6 Standard to which it confirms 7 Approved by TAC 8 Bill of material indicating no., size, type & pressure rating enclosed with the offer 9 Illustrative leaflets attached (j) NON-RETURN VALVE (AIR / WATER) 1 Manufacturer 2 Type 3 Material of construction a)Body b)Valve trim 4 Flange particulars 5 Standard to which it confirms 6 Approved by TAC 7 Bill of material indicating no., size, type & pressure rating enclosed with the offer 8 Illustrative leaflets attached (k) BASKET STRAINER 1 Manufacturer 2 Type 3 Number provided

Unit

Guaranteed Particulars

(Yes/No) (Yes/No) (Yes/No)

(Yes/No) (Yes/No) (Yes/No)

(Nos.)

-146Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 4 Capacity of each strainer 5 Material of construction: a)Body b)Strainer 6 Pressure drop in clean condition 7 Standard to which it conforms 8 Approved by TAC 9 Illustrative leaflets attached. (l) FIRE HYDRANT (SINGLE / DOUBLE HEADED) 1 Manufacturer 2 Type 3 Number provided 4 Material of construction: a)Body b)Trim c)Handwheel d)Washer, gasket etc. e)Quick coupling connection f)Spring g)Cap with chain 5 Standard to which it conform 6 Approved by TAC 7 Illustrative leaflets attached (m) BRANCH PIPES & NOZZLES 1 Manufacturer 2 Type

Unit (cu. m)

Guaranteed Particulars

(kg/sq. cm) (Yes/No) (Yes/No)

(Yes/No) (Yes/No)

-147Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 3 Number provided 4 Diameter of the nozzle 5 Material of construction: a)Branch Pipe b)Nozzle 6 Standard to which it conform 7 Approved by TAC 8 Illustrative leaflets attached (n) HOSE PIPES & INSTANTANEOUS SPRING TYPE COUPLING 1 Manufacturer 2 Type 3 Number provided a)63mm, 7.5m long hose b)63mm, 15m long hose 4 Material of construction a)Hose pipe b)Coupling 5 Standard to which it conforms 6 Approved by TAC 7 Illustrative leaflets attached (o) HOSE CABINETS (FOR INDOOR HYDRANTS) 1 Overall dimensions 2 Material of construction 3 Accessories included 4 Total number provided

Unit

Guaranteed Particulars

(mm)

(Yes/No) (Yes/No)

(Yes/No) (Yes/No)

(mm) (Yes/No)

-148Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 5 Standard to which it conforms 6 Approved by TAC 7 Illustrative leaflets attached (p) CENTRAL HOSE STATION 1 Overall dimensions 2 List of accessories included 3 Total number provided 4 Standard to which it conforms 5 Approved by TAC 6 Illustrative leaflets attached (q) AUTOMATIC SMOKE DETECTOR 1 Name of manufacturer and address 2 Type of detector 3 Brief description of the principle of detection 4 Sensitivity range 5 Whether sensitivity is adjustable 6 Whether adjustment stipulated above is stepless 7 Type of mounting (wall/column etc.) 8 Recommended mounting height 9 Details of enclosure for detector 10 Whether detector is plug in type 11 Type of output contact 12 Rating of output contact 13 Area covered by single detector 14 Configuration of area covered/zone of protection 15 Whether response indicator is provided

Unit

Guaranteed Particulars

(Yes/No) (Yes/No) (mm) (Yes/No) (Nos.) (Yes/No) (Yes/No)

(Yes/No) (Yes/No) (mm) (Yes/No) (V, A, AC/DC) (sq. m) (Yes/No)

-149Section - IX : Guaranteed & other Technical Particulars

Sl. Unit Description No. 16 Details of painting, ordinary / chlorinated rubber / epoxy 17 Specific maintenance requirement, if any 18 Details of coating/plating for corrosion resistance (Yes/No) 19 Whether detectors are certified by DAE 20 Applicable Standard (Yes/No) 21 Test certificates copies enclosed (Yes/No) 22 Whether flame proof cable gland is included (r) AUTOMATIC DELUGE VALVE FOR HVW SPRAY SYSTEM 1 Name of manufacturer 2 Type 3 Material of construction a)Body b)Valve internal c)Seat seal d)Diaphragm (kg/sq. cm) (g) 4 Air/Water pressure required for actuation (kg/sq. cm) (g) 5 Operating water pressure required 6 Water motor gong: a)Type and number b)Manufacturer c)Material of construction 7 Standard to which it conforms (Yes/No) 8 Auxiliary contacts for indicating Low air pressure Fire and Tripping of the equipment in the event of fire provided

Guaranteed Particulars

-150Section - IX : Guaranteed & other Technical Particulars

Sl. Unit Description No. (Yes/No) 9 Whether capable of resetting manually? 10 Whether provided with manual/mechanical operating (Yes/No) device? (Yes/No) 11 Whether indicating device provided to indicate if valve is in close or open position? (Yes/No) 12 Whether flow control valve complete with testing drain valves, manual operation arrangement, supporting structures and bidder necessary 13 Number & Size of the deluge valves provided with each of the equipment to be protected. (Yes/No) 14 Whether approved by TAC? (Yes/No) 15 Whether approved by UL/FM/VDS (Yes/No) 16 Illustrative leaflets attached (s) PROJECTOR / NOZZLE FOR HVW SPRAY SYSTEM 1 Name of manufacturer 2 Type 3 Material of construction a)Outside Body b)Internal/external deflectors 4 Standard to which it conforms 5 Flow capacity, at rated pressure (may be furnished as (cu.m/hr) capacity v/s pressure graph) - size wise (kg/sq. cm) (g) 6 Min. pressure required at projector/nozzle inlet for proper formation of spray (Degrees) 7 Nozzle angle

Guaranteed Particulars

-151Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 8 Range and effective coverage of each size of projector/nozzle at the acceptable min. pressure. 9 No. & Size of projector/nozzle provided for each type of risk a) Risk b) Projector Size No. c) Nozzle Size No. 10 Projector/nozzle approved by TAC 11 Projector/nozzle approved by UL/FM/VDS 12 Illustrative leaflets attached (t) QUARTZOID BULB FOR HVW SPRAY SYSTEM 1 Manufacturer 2 Type 3 Material used for sensing element 4 Element dimensions 5 Operating temperature limit 6 Percentage of sensing discrimination 7 Life of the element 8 Max. withstanding discriminating force 9 Duration of sensing at rated temperature for actuation of the element 10 No. of heat detector provided for each type of transformer/equipment to be protected 11 Heat detectors/Quartzoid bulb approved by TAC 12 Heat detector/Quartzoid bulb approved by UL/FM/VDS

Unit (m, sq. m)

Guaranteed Particulars

(Yes/No) (Yes/No) (Yes/No)

(mm) (Deg. C) (%) (hours) (N)

(Yes/No) (Yes/No)

-152Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 13 Illustrative leaflets attached (u) SAND / WATER BUCKETS 1 Manufacturer 2 Standard to which it conforms 3 Capacity 4 Number provided 5 Provided with hanging arrangement 6 Whether approved by TAC? (v) DRY POWDER TYPE EXTINGUISHER 1 Manufacturer 2 Principle of operation 3 Capacity 4 Type of extinguisher (Low/High pressure) 5 Shape 6 Material of construction a) Body b) Inner shell c) Neck ring d) Cap e) Plunger f) Cartridge holder and sealing device g) Piercer h) Spring i) Syphon tube j) Nozzle and discharge fittings k) Cartridge l) Hose

Unit (Yes/No)

Guaranteed Particulars

(cu. m) (Yes/No) (Yes/No)

(cu. m)

-153Section - IX : Guaranteed & other Technical Particulars

Sl. No. 7 8 9 10 11 12 13 14 15 16 17

Description Range of throw of jet Whether dry powder charge conforms to IS 4308 Max. period of discharging 95% of chemical Test pressure for extinguisher body Whether handle provided Whether seal provided to indicate that extinguisher has not been used Whether anti-corrosive treatment provided? Whether First charge of chemical supplied? List of accessories provided Painting Whether extinguisher is capable of discharging not less than 85% by mass of the actual rated capacity of dry powder at an angle of 45 degree from horizontal

Unit (m) (Yes/No) (Sec) (kg/sq. cm) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

Guaranteed Particulars

18 19 20 21

List of Test certificate provided Standard to which it conforms Whether approved by TAC? Whether each extinguisher has the marking as per IS 2171 22 Whether approved by the chief inspector of explosives Govt, of India 23 Whether illustrative leaflets attached (w) PORTABLE CARBON DIOXIDE EXTINGUISHER 1 Manufacturer 2 Capacity

(Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

(cu. m)

-154Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 3 Number provided 4 Material of construction: a) Brass tube b) Siphon or discharge tube c) Wheel of operating head d) Body e) Discharge valve or operating head f) Hose g) Discharge horn h) Carrying handle 5 Type of valve provided 6 Standard to which it conforms 7 Provided with handling arrangement 8 Whether seal to indicate that extinguisher has not been used provided? 9 Whether safety release provided? 10 Whether supplied with first charge of extinguisher agent? 11 Whether each extinguisher has the marking as per IS 2878 12 Whether approved by TAC? 13 Whether approved by the chief inspector of explosive Govt. of India 14 Whether illustrative leaflets attached 15 List of Test certificate provided 16 Standard to which CO2 extinguisher conforms

Unit (Nos.)

Guaranteed Particulars

(Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

-155Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description (x) FOAM TYPE PORTABLE EXTINGUISHER Manufacturer Standard to which it conforms Type Capacity Number provided Max. effective range when tested in still air Min. period during which jet shall be maintained at a length of not less than 10 m. Max. period for discharging 95% solution Test pressure for extinguisher body Test pressure for hose Whether handle is provided? Whether provided with hanging arrangement Whether provided seal to indicate that extinguisher has not been used Supplied with first charge of chemical List of accessories provided Whether each extinguisher has the marking as per IS Whether approved by TAC? Whether illustrative leaflets attached Test Certificates enclosed (y) SIREN Name of the manufacturer Range Duration of sounding

Unit

Guaranteed Particulars

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1 2 3

(cu. m) (Nos.) (m) (Sec) (Sec) (kg/sq. cm) (kg/sq. cm) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

(m)

-156Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit (Sec) (Sec) (Yes/No) (Yes/No) (Yes/No) (Yes/No)

Guaranteed Particulars

a) Minimum b) Maximum 4 Whether operationable from fire control room 5 Whether associated switchgear provided 6 Whether luminous coloured lamp over siren provided as per specification 7 Whether all accessories provided (aa) BCF (HALON 1211) TYPE PORTABLE EXTINGUISHER 1 Manufacturer 2 Standard to which it conforms 3 Capacity 4 Number provided 5 Whether each container provided with the following accessories a) Siphon tube b) Hose c) Discharge horn d) Carrying handle 6 Type of valve provided 7 Standard to which the valve shall conform 8 Provided with handling arrangement 9 Whether provided with seal to indicate that extinguisher has not been used. 10 Whether safety release provided? 11 Whether supplied with first charge of extinguisher agent?

(cu. m) (Nos.)

(Yes/No) (Yes/No) (Yes/No) (Yes/No)

(Yes/No) (Yes/No) (Yes/No) (Yes/No)

-157Section - IX : Guaranteed & other Technical Particulars

Sl. No. 12 13 14 15 16

Description

Unit (kg/cu. m) (%) (Sec) (Yes/No)

Guaranteed Particulars

Fill density of cylinder Toxicity level of halon 1211 Time required for supplying a fresh charge of BCF Whether each extinguisher has the marking Whether approved by TAC?/any other recognized International agency 17 Name of international agency 18 Whether illustrative leaflets attached (ab) HOISTING EQUIPMENT 1 2 3 4 5 6 7 8 Name of the manufacturer Lift Lifting capacity Runway Duty class of chain pulley block as per IS: 3832 Applicable standard Total weight Chain Pulley Block a) Name of the manufacturer b) Type c) Safe working load d) Lift e) No. of falls f) Load chain grade/size g) Material of construction of each component h) Factor of safety i) Velocity Ratio

(Yes/No)

(m) (tonnes) (m)

(Kg)

(tonnes) (m)

-158Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit (Yes/No)

Guaranteed Particulars

j) Hand chain required to be passed over for lifting load through one (1) meter height k) Applicable Standard l) Weight of chain pulley block 9 Type of bearings (furnish component/sub assembly wise details) 10 Hook a) Type b) Safe working load c) Material of construction as per IS:1875 d) Factor of safety e) Type of bearings provided f) Whether the hook shall be free to swivel in the loaded condition without twisting the load chain g) Applicable Standard 11 Load Chain a) Grade of the chain b) Size of the chain c) Material of construction d) Whether pitched and polished e) Chain Link dimensions i) Pitch (inside length) ii) Outside width f) Applicable Standard 12 Hand Chain a) Grade b) Size

(Kg)

(tonnes)

(Yes/No)

(mm) (Yes/No) (mm) (mm)

(mm)

-159Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars

c) Material (Yes/No) d) Whether pitched and polished e) Chain Link dimensions (mm) i) Pitch (inside length) (mm) ii) Outside width (Kg) f) Maximum pull on hand chain required for specific capacity g) Applicable Standard (Yes/No) 13 Whether means have been provided to ensure effective guidance of the load chain into chain wheel (Yes/No) 14 Whether chain pulley block have been provided with idler wheels to avoid twisting of the chain while passing around, if yes, indicate pitch dia of idler Note = Technical particulars for blank spaces will be forwarded

-160Section - IX : Guaranteed & other Technical Particulars

IV. ANCILLIARY ITEMS ( 132 & 33 KV ) Sl. Description No. A. INSULATORS / STRINGS (I) DISC INSULATOR UNITS (a) Physical Characteristics 1 Type 2 Colour (Porcelain insulator) 3 Surface 4 Locking device 5 Diameter 6 Spacing 7 Size and desgnation of pin ball shank 8 Minimum creepage distance 9 Minimum Electro-mechanical strength (b) Electrical characteristics 1 Minimum impulse dry withstand test voltage (+Ve Wave) 2 Minimum power frequency puncture withstand test voltage 3 Minimum power frequency one minute withstand voltage i) Dry ii) Wet 4 Minimum visible discharge test voltage 5 Maximum RIV at 10 kV (rms) (II) COMPLETE INSULATOR STRINGS 1 Number of Insulator discs a)Suspension string b)Double tension string 2 Lightning impulse withstand voltage 3 Power frequency wet one minute withstand voltage 4 Corona extinction voltage 5 RIV at 1 MHz for complete string i.e., including grading/corona rings, arcing horns, clamps etc., and 105 kVrms for 132 kV system (not exceeding) 6 Mechanical failing load a)Suspension b)Double Tension 7 Maximum length of suspension string from ball hook attachment at hanger to centre line of conductor (approx.) a)Suspension b)Double Tension 8 Maximum voltage across any disc. B. INSULATOR HARDWARE (I) Free centre type suspension clamp 1 Clamp Body/ keeper piece a)Material b)Process of treatment

Unit

Guaranteed Particulars

(mm) (mm) (mm) (mm) (kN) (kV peak) (kV rms)

(kV rms) (kV rms) (kV rms) ( m V)

(kV peak) (kV rms) (microvolts)

(kN) (kN)

(mm) (mm) (%)

-161Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars

c)Reference standard 2 Cotter bolts, Hangers, Shackles, Brackets a)Material b)Process of treatment c)Reference standard 3 U Bolts a)Material b)Process of treatment c)Reference standard 4 Preformed Armour Rods (Min. tensile strength of 35 kg/sq. mm) a)Material b)Process of treatment c)Reference standard 5 AGS Clamp (i)Supporting House a)Material b)Process of treatment c)Reference standard (ii)Al. Insert & retaining strap a)Material b)Process of treatment c)Reference standard 6 Elastomer Cushion a)Material b)Process of treatment c)Reference standard (II) Tension Clamp 1 Type 2 Material i) Outer sleeve ii) Inner sleeve 3 Minimum failing load (No deformation) (III) Dimensions and dimensional tolerance of the cross section of aluminium and steel ends. 1 For MOOSE (If applicable) (a)Al. Sleeve (i) Dimension before compression - Inner dia
(kN)

(mm)

-162Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

Guaranteed Particulars

- Outer dia (ii) Dimension after compression - Corner to corner width - Face to face width (b)Steel Sleeve (i) Dimension before compression - Inner dia - Outer dia (ii) Dimension after compression - Corner to corner width - Face to face width 2 For ZEBRA (a)Al. Sleeve (i) Dimension before compression - Inner dia - Outer dia (ii) Dimension after compression - Corner to corner width - Face to face width (b)Steel Sleeve (i) Dimension before compression - Inner dia - Outer dia (ii) Dimension after compression - Corner to corner width - Face to face width (IV) Arcing Horns 1 Type 2 Material

(mm) (mm) (mm) (mm)

(mm) (mm) (mm) (mm)

(V) Grading/Corona Ring 1 Material 2 Capacity to withstand load for one minute 3 Supporting Brackets and Mounting Bolts
(kN or Kg)

(VI) Other String Hardwares 1 Material i) Socket ended items ii) Sag adjustment device iii) Ball ended components, U-clevis and chain link iv) Yoke Plates 2 Security clips

-163Section - IX : Guaranteed & other Technical Particulars

Sl. No. i) Type (ii) Material 3 C. 1 2 3 4 5 6 7

Description

Unit

Guaranteed Particulars

Rated Strength of fittings TUBULAR BUS CONDUCTOR Voltage class Size Outer Diameter Inner diameter Thickness Cross sectional area Type designation

(kV) (mm) (mm) (mm) (sq. mm)

8 Tensile strength 9 10 D. 1 Weight Current rating at 75 Deg. C CLAMPS AND CONNECTORS For connecting ACSR conductors and aluminium tubes

(Kg/mm ) (Kg/m ) (Amp)

2 Suspension clamps 3 Dead end compression clamps for connecting GI shield wire: 4 i)Bolts, Nuts ii)Mild steel plain washers below M12. iii)Spring washers 5 For connecting equipment terminals made of copper with ACSR conductors. E. MARSHALLING KIOSKS 1 Type 2 No. of terminals 3 Thickness of sheet steel 4 Conductor for internal wiring and size 5 Incoming supplies 6 Outgoing supplies 7 Terminal blocks 8 Degree of protection 9 Painting 10 Other provision F. BUS POST INSULATORS 1 Rated Voltage 2 Type 3 Dry & wet one minute power frequency with stand voltage.
(kV) (kV rms) (mm) (sq. mm) (V, A, sq. mm) (V, A, sq. mm)

-164Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 4 1.2/50 micro second Lightning impulse withstand voltage 5 Minimum total creepage distance 6 Total cantilever strength 7 Top p.c.d 8 Corona extinction voltage 9 Guaranteed loads a)Bending b)Torsion c)Compression 10 RIV for frequency between 0.5 MHz and 1 MHz and at 1.1x rated phase to earth voltage G. CONDUCTORS AND ACCESSORIES 1 Conductor 2 IS applicable 3 Wire diameter (a) Aluminium (b) Steel 4 Number of strands: (a) Steel centre (b) 1st steel layer (c) 1st Aluminium layer (d) 2nd Aluminium layer (e) 3rd Aluminium layer 5 Sectional Area of Aluminium 6 Total Sectional Area 7 Overall diameter 8 Approximate weight 9 Calculated D.C. resistance at 20 degrees C, maximum. 10 11 12 13 Ultimate tensile strength Final modulus of elasticity Coefficient of Linear expansion. Lay-Ratio Steel core 6 wire layer Aluminium 1st layer (12 wire) 2nd layer (18 wire) 3rd layer (24 wire) 14 Technical particulars of Aluminium and Steel strands a) Diameter Standard Maximum Minimum b) Cross-sectional area c) Weight

Unit (kV peak) (mm) (kN or Kg ) (mm) (kV rms) (N) ( N-m ) (N-m ) ( m V)

Guaranteed Particulars

(mm) (mm)

(sq. mm) (sq. mm) (mm) (Kg/km ) (Ohms/km)

(kN) (Kg/sq. cm) (per Deg. C) (max, min) (max, min) (max, min) (max, min)

(mm) (mm) (mm) (sq. mm) (Kg/km)

-165Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars

d) Minimum breaking load Before stranding After stranding 15 D.C. Resistance at 20 Degrees C 16 Zinc coating of steel core a) Number of 1 minute dips b) Minimum weight of Zinc coating c) Process of Galvanizing d) Quality of Zinc 17 Joints in strands a) Steel b) Aluminium c) Method of making joint d) Ultimate tensile strength of joint 18 Chemical composition of high carbon steel wire Element i) Carbon ii) Manganese iii) Phosphorus iv) Sulphur v) Silicon H. GALVANISED STRANDED STEEL EARTHWIRE 1 Material 2 Purity of Material 3 Stranding and wire diameter 4 No. of strands 5 Weight 6 Single wire before stranding a) Diameter of wire strand Maximum Minimum b) Minimum elongation in 200 mm length c) Minimum tensile strength d) D.C. resistance at 20 Deg. C 7 Stranded wire a) Length of lay Maximum Minimum b) Minimum breaking load c) Overall diameter d) Modulus of elasticity e) Coefficient of linear expansion f) D.C. resistance at 20 degC

(kN) (kN) (Ohms/km)

(gm/sq. m) (%)

(Kg/sq. m )

(%) (%) (%) (%) (%)

(%) (mm) (Nos.) (Kg/km) (mm) (mm) (mm) ( %) (N/sq. mm) (Ohms/km)

(mm) (mm) (kN) (mm) (Kg/sq. mm) (per Deg. C) (Ohms/km)

-166Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description g) Total sectional area

Unit (sq. mm)

Guaranteed Particulars

8 Direction of lay of outer layer 9 Zinc coating a) Number of one minute b) Number of half minute dips c) Quality of Zinc d) Weight of coating on wire e) Process of galvanising 10 Joints 11 Oiling 12 Chemical composition Element i) Carbon ii) Manganese iii) Phosphorus iv) Sulphur v) Silicon I. SPACERS/SPACER DAMPERS 1 Type 2 Sub-conductor spacing 3 Arrangement of sub-conductors in the bundle 4 Galvanisation a)Spring washers b)Other ferrous parts 5 Elastomers 6 Clamp bolt strength 7 Short-circuit rating 8 Equivalent compressive and tensile strength requirements 9 Slip strength of clamps (Both for bolted and rubber surfaced type) 10 Mechanical Movements a)Longitudinal parallel to conductors b)Vertical perpendicular to conductors c)Torsional angular movement in a vertical plane parallel to the conductors. 11 Vibration Requirement a) Radio Interference voltage at phase to ground voltage of 105 kV(rms) for 132 kV system and frequency 1MHz b) Corona extinction voltage J. TENSION CLAMPS FOR EARTHWIRE 1 Type 2 Material -167Section - IX : Guaranteed & other Technical Particulars

(%) (gm/sq. m)

(%) (%) (%) (%) (%)

(mm)

(kN) (kA, Sec)

(kN)

(mm) (mm) (Deg.)

(microvolts)

(kV rms)

Sl. No.

Description a)Body b)Bolts & Nuts Minimum failing load Minimum slip strength Galvanisation a)Spring washers b)Other ferrous parts FLEXIBLE COPPER BONDS Material Strand & Wire diameter Length HRH MS bolt hot-dip galvanised with nut & lock washer TERMINAL BLOCKS Voltage grade No. of spare terminals

Unit

Guaranteed Particulars

3 4 5

(Kg) (Kg)

K. 1 2 3 4 L. 1 2

(mm) (mm)

(Volts) (Nos.) (Yes/No)

3 Whether it is suitable for connecting CTs & PTs circuits & all other circuits 4 Clearance a)Between first row of terminal block & cable gland plate or side of box b)Between two rows of terminal blocks 5 Connecting lugs suitable for M. EARTHING MAT 1 General a) Specification / Standards followed b) Design ambient temperature c) Areas of switchyard (L x W) d) Average soil resistivity e) Type of soil (homogenous / non-homogenous) f) Degree of corrosive nature of soil 2 Earthing mat data a) Area under which the mat will be laid (L x W) b) Termination distance of earthing mat with reference to switchyard fencing c) Depth of burial of earthing mat d) Size of earthing mat grids (L x W) e) Details of switchyard earthing mat conductor i) Size material and shape ii) Allowance made for corrosion

(mm) (mm) (sq. mm)

(Deg. C) (m x m) (Ohm-m)

(m x m) (m) (m) (m x m)

(mm) (%)

-168Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description iii) Length of conductor

Unit (m) (Kg) (Sq.mm) (%) (m)

Guaranteed Particulars

iv) Weight f) Detail of risers i) Size material and shape ii) Allowance made for corrosion iii) Length of conductor

iv) Weight g) Details of conductor for connections to earthing points of current carrying parts i) Size material and shape ii) Allowance made for corrosion iii) Length of conductor iv) Weight h) Details of conductors for connection to non-current carrying parts i) Size material and shape ii) Allowance made for corrosion iii) Length of conductor iv) Weight 3 Equipment earthing electrode systems a) Details of earthing system for potential transformers i) Number and material of earthing electrodes ii) Diameter and length of electrode iii) Size and material of conductors b) Details of earthing system for capacitor voltage transformers i) Number and material of earthing electrodes ii) Diameter and length of electrode iii) Size and material of conductors c) Details of earthing system for lightning arrestors i) Number and material of earthing electrodes ii) Diameter and length of electrode iii) Size and material of conductors 4 Fault current for which the earthing mat is designed 5 Duration of fault assumed for design 6 Duration of shock

(Kg)

(Sq.mm) (%) (m) (Kg)

(Sq.mm) (%) (m) (Kg)

(Nos.) (mm, mm) (mm)

(Nos.) (mm, mm) (mm)

(Nos.) (mm, mm) (mm) (kA) (seconds) (seconds)

-169Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 7 Resistivity of surface layer 8 Size of crushed rock and thickness of layer 9 Estimated value of earthing mat resistance 10 Estimated values of a) Touch potential b) Step potential c) Ground potential rise d) Transferred potential 11 Measures envisaged to be taken to limit the various potentials within safe limits, if the estimated values are found to exceed the safe limits. 12 Size of weld for welded joints 13 Number of diameter of bolts for bolted joints 14 Locations where bolted joints shall be provided 15 Protection measures against corrosion of a) Welds b) Earthing mat conductors c) Bolted connections d) Risers and other connectors 16 Drawings (Attach drawings showing details of earthing mat, arrangements for connections to various system, equipment fence etc., details of welds, bolted joints etc., and bill of materials as per this specification ) 17 Tests 18 List of tests that the bidder will carry out N. DIRECT STROKE LIGHTNING PROTECTION SYSTEM 1 General a) Type of protection system b) Applicable specification and standards 2 Lightning Masts a) Number of lightning masts required for shielding the entire switchyard and transformer yard b) Height of lightning masts c) Does the total mast height consists of switchyard structure and pipe fixed on the top of masts d) If yes, give the breakup of heights i) Switchyard structure ii) Pipe

Unit (Ohm-m) (mm) (Ohms)

Guaranteed Particulars

(Volts) (Volts) (Volts) (Volts)

(mm) (m)

(Nos.)

(m) (Yes/No)

(m) (m)

-170Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. e) Diameter and material of pipe and weight / unit length f) Size of shield wire 3 Drawings (Please enclose calculations, drawing, bill of materials etc., as stipulated in this specifications) O. CONNECTORS 1 TEE connectors i) Arrangement of the offered connectors for a) Single conductor bus b) Bundle conductor bus c) Clamps associated with bundle conductor bus and tapping d) Rated terminal load and factor of safety ii) Material a) Clamp body b) Spacer member c) Bolts, nuts and washers d) Lock nuts e) Liners, if any iii) Rated current iv) Maximum temperature rise over specified design ambient temperature when carrying rated current v) Minimum failing load vi) Minimum slip strength of clamps/connector vii) Minimum thickness of any part viii) Weight of connector complete with hardware a) Suitable for single conductor per phase b) Suitable for bundle conductor per phase ix) Corrosion protection treatment provided 2 Parallel groove clamps i) Type ii) Material a) Clamp body b) Bolts, nuts & washers c) Lock nuts iii) Rated current iv) Features incorporated to ensure proper clamping of conductor without injury to aluminimum strands v) Recommended torque for tightening the bolts to prevent conductor slippage

Unit (mm, Kg) (mm)

Guaranteed Particulars

(kN)

(Amp) (Deg. C) (kN) (kN) (mm)

(Kg) (Kg) (Yes/No)

(Amp)

(N-m)

-171Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. vi) Maximum temperature rise over specified design ambient temperature when carrying rated current vii) Maximum contact resistance when installed with the recommended torque viii) ix) x) xi) 3 i) ii) a) Number and diameter of bolts per clamp Weight of clamp complete with hardware Minimum thickness Corrosion protection treatment provided Post insulator clamp Type Material Clamp body

Unit (Deg. C) (Ohms)

Guaranteed Particulars

(Nos.., mm) (Kg) (mm) (Yes/No)

b) Bolts, nuts and washers c) Bolts, nuts and washers iii) Rated current iv) Maximum temperature rise over specified design ambient temperature when carrying rated current v) Recommended torque for tightening the bolts to ensure proper gripping of conductor without injury to aluminimum stands vi) Maximum contact resistance when installed with the recommended torque vii) Number and diameter of bolts per clamp viii) Weight of clamp complete with hardware ix) Minimum thickness x) Corrosion protection treatment provided P. CABLE TRAYS, TRAY COVERS & ACCESSORIES 1 Manufacturer's Name & Address 2 Manufacturer's type designation 3 Material specification 4 Thickness of sheet steel for cable trays and fittings like elbows tees, crosses etc. 5 Maximum permissible loading for 2.5 m long tray simply supported at the ends 6 Corresponding deflection at centre for the loading 7 Whether hot dip galvanized 8 Weight of zinc coating & minimum thickness of zinc deposit at any spot Q. JUNCTION BOXES
(mm)

(Amp) (Deg. C) (N-m)

(Ohms)

(Nos.., mm) (Kg) (mm) (Yes/No)

(Kg or kN)

(mm, mm) (Yes/No) (gm/sq. m)

-172Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 1 Manufacturer's Name & Address 2 Manufacturer's type designation 3 Material specification 4 Type of enclosure with degree of protection 5 Thickness of GI sheet 6 Terminal a) Make b) c) d) e) f) Current rating Voltage rating Stud type Complete with insulated barriers Whether suitable for 2 Nos. 2.5 mm copper conductor g) Whether descriptive pamphlet is enclosed

Unit

Guaranteed Particulars

(mm)

(Amp) (Volts) (Yes/No) (Yes/No) (Yes/No)

R. COMPRESSION TYPE CABLE GLAND 1 Manufacturer's Name & Address 2 Manufacturer's type designation 3 Material 4 Whether passivated or not S. CABLE LUGS 1 Manufacturer's Name & Address 2 Manufacturer's type designation 3 Current rating 4 Material specification 5 6 T. 1 Tinned Solder less crimping type STRAIGHT THROUGH JOINTS Manufacturer's Name & Address
(Yes/No) (Yes/No) (Amp) (Yes/No)

2 heat shrinkable type taped type/premoulded type 3 Whether bill of materials of the kit furnished 4 Whether straight through joint kit is complete with all accessories U. CABLE CLAMPS 1 Manufacturer's Name & Address
(Yes/No) (Yes/No)

-173Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 2 Material specification, size and type of clamps / cords a) For single core cables b) For multi core cables c) For cable in trefoil formation V. ENCLOSURES 1 Whether the drawings for various ancillary items enclosed 2 Whether all the type test report for various items enclosed 3 Whether descriptive technical literature for various items enclosed

Unit

Guaranteed Particulars

(mm) (mm) (mm)

(Yes/No)

(Yes/No) (Yes/No)

-174Section - IX : Guaranteed & other Technical Particulars

V. Sl. No. 1 2 3 4 5 6 7 8 Description

POWER TRANSFORMER
Unit

Guaranteed Particulars

10 11

12

13 14 15

16

17

Name and Address of the Manufacturer Governing standard Service (Hz) Rated frequency (Nos.) No. of phases Type of cooling (Nos.) No. of windings Rating (MVA) a) With ONAN cooling (MVA) b) With ONAF cooling Rated voltages (kV) a) HV (kV) b) LV Connection Symbol. Temperature rise of oil above reference peak ambient temperature (Deg. C) a)At full ONAN rating (Deg. C) b)At full ONAF rating Temperature rise of windings, above reference peak ambient temperature (Deg. C) a)At full ONAN rating (Deg. C) b)At full ONAF rating (Deg. C) Temperature gradient between windings and oil. (Deg. C) Limit of hot spot temperature for which the transformer is designed Time in minutes for which the transformer can be run at full load without exceeding the maximum permissible temperature at reference ambient temperature when : (minutes) a)Supply to fans is cut off. (kW) a)Guaranteed no load losses at rated voltage, normal ratio and rated frequency and 75 Degree Centigrade average winding (%) temperature. b)State whether the losses are firm or subject to tolerance. In a case it is subject to tolerance indicate the ceiling for tolerance. a)Guaranteed load losses at rated output, rated frequency, corrected for 75 degree centigrade winding temperature for the: (kW) i)Principal Tap (kW) ii)Lowest tap (kW) iii)Highest tap (%) b)State whether the losses are firm or subject to tolerance. In a case it is subject to tolerance indicate the ceiling for tolerance.

-176Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 18 a)Guaranteed cooler losses at rated output, normal ratio, rated voltage, rated frequency at ambient temperature of 38 degree centigrade. b)State whether the losses are firm or subject to tolerance. In a case it is subject to tolerance indicate the ceiling for tolerance. 19 Withstand time for three phase short circuit at terminals 20 Over Excitation withstand time. a)125% b)140% c)150% 21 Positive sequence impedence on rated MVA base, at rated current and frequency and 75 Degree Centigrade winding temperature at HVLV a)Principal Tap b)Lowest tap c)Highest tap 22 Zero sequence impedance at principal tap 23 Leakage reactance for HV and LV 24 Capacitance to earth for HV and LV 25 Efficiency at 75 Degree centigrade winding temperature at Unity Power Factor (UPF) and 0.85 PF (lagging) a)On 100% Load b)On 75% Load c)On 50% Load 26 Regulation at full load at 75 Degree centigrade expressed as a percentage of normal voltage, at a)Unity power factor b)0.85 power factor (Lagging) 27 Core data a)Material for core laminations. b)Thickness of laminations c)Insulation between core lamination d)Insulation of core bolts, washers, end plates etc. e)Maximum flux density in steel at rated voltage, frequency and at 90%, 100% and 110% voltage f)Number of limbs of the core. g)Magnetizing inrush current h)No-load current at normal ratio and frequency for (i) 85 Percent of rated voltage (ii) 100 Percent of rated voltage (iii) 105 Percent of rated voltage

Unit (kW)

Guaranteed Particulars

(%)

(Sec)

(Sec) (Sec) (Sec)

(Ohms, pu) (Ohms, pu) (Ohms, pu) (Ohms, pu) (Ohms, pu) (pF, pu)

(%) (%) (%)

(%) (%)

(mm)

(Tesla)

(mA)

(Amp) (Amp) (Amp)

-177Section - IX : Guaranteed & other Technical Particulars

Sl. Description No. 28 Core bolt insulation withstands voltage for one minute 29 Data on windings i)Maximum current density at CMR and conductor area a)HV b)LV ii)Conductor material a)HV b)LV iii)Insulating material used for a)HV winding/LV Winding iv)Insulating material used between a)IV and LV winding b)LV winding and core v)Details of special arrangement provided to improve surge voltage distribution in the winding. vi)Whether HV winding interleaved vii)Position of tapping on the winding viii)Maximum current density under short circuit a)HV b)LV 30 Test Voltages i)Lightning withstand test voltage ii)Power frequency withstand test voltage 31 Partial discharge level 32 Noise level when energized at normal voltage and frequency without load 33 Whether the offered transformer can be transported on Indian Railways to destination 34 Cooling System a) Make and type i) Radiators ii) Fans iii) Pumps b) Number of cooler banks c) Number of fan per cooler bank d) Number of standby fans e) Rated power input capacity f) Rated voltage g) Efficiency of motor at full load h) Temperature rise of motor at full load i) BHP of driven equipment j) Temperature range over which cooler control is adjustable k) Whether fans are suitable for continuous operation at 85 percent of their rated voltage

Unit (kV)

Guaranteed Particulars

(A/sq. mm) (A/sq. mm)

(Yes/No)

(A/sq. mm) (A/sq. mm) (kV peak) (kV rms) (pC) (dB) (Yes/No)

(kW) (Volts) (%) (Deg. C) (BHP) (Deg. C) (Yes/No)

-178Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars

l) Calculated time constant i) Natural cooling ii) Forced air cooling 35 On-Load tap changing Gear a) Make and type b) Rated current c) Rated voltage d) Number of steps e) Step voltage f) Whether control suitable for i) Remote/local operation ii) Auto/manual operation iii) Parallel operation g) Rated voltage of drive motor h) Rated voltage of control devices provided i) Particulars of protective devices provided j) Whether control panel complete with OLTC control equipment for installation in the control room included in the scope of supply at no extra cost. k) Time taken to change one step 36 Bushings a) Make and type b) Rated current c) Lightning impulse withstand voltage d) Power frequency withstand voltage i) Wet for one minute ii) Dry for one minute f) Visible corona discharge voltage g) Partial discharge level h) Creepage distance in air i) Quantity of oil in bushing and specification of oil used j) Weight of assembled bushing k) Free space required above the transformer tank top for removal of tank l) Whether terminal connector for all bushings included in the scope of supply m ) Are bushing dimensions as per n ) Whether test tap provided or not 37 Conservator a) Total volume b) Volume between the highest and lowest visible oil levels c) Material of air cell d) Continuous temperature withstand capacity of air cell 38 Tank

(hours (hours

(Amp) (Volts) (Nos.) (Volts) (Yes/No) (Yes/No) (Yes/No) (Volts) (Volts) (Yes/No)

(Sec)

(Amp) (kV peak) (kV rms) (kV rms) (kV rms) (pC) (mm) (litres) (Kg) (mm) (Yes/No) (Yes/No) (Yes/No) (cu. m) (cu. m)

(Deg. C)

-179Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description a) Material and thickness of plate for tank construction b) Tank cover conventional or Bell type c) No. of Pressure relief devices provided d) Operating pressure of relief device Bushing Type Current Transformers a) Voltage class b) Number of cores c) Ratio d) Accuracy class e) Burden f) Accuracy limit factor g) Maximum resistance of secondary winding h) Knee point voltage i) Current rating of secondaries Vacuum withstand capacity of a) Main tank b) Radiators and accessories Pressure withstand capacity of a) Main tank b) Radiators and accessories Oil a) Quantity of oil (Before filling & Before commissioning) b) Moisture content c) Tan delta at 90 Degrees centigrade d) Resistivity e) Breakdown strength f) Interfacial tension at 20 Degree centigrade g) Quantity supplied h) Applicable standard

Unit

Guaranteed Particulars

(kN/sq. m) (kV)

39

40

(mm Hg) (mm Hg) (kN/sq. m) (kN/sq. m) (litres) (%) (Ohm-cm) (kV) (N/m) (litres)

41

42

43 Temperature Indicators a) OTI i)Range ii)Accuracy b) WTI i)Range ii)Accuracy c) RWTI i)Range ii)Accuracy 44 Minimum clearance a) HV i) In oil Between phases Phase to ground ii) In air Between phases Phase to ground

(mm) (mm) (mm) (mm)

-180Section - IX : Guaranteed & other Technical Particulars

Sl. No.

Description

Unit

Guaranteed Particulars

b) LV i) In oil Between phases Phase to ground ii) In air Between phases Phase to ground 45 Weights and Dimensions i) Weights a) Core b) Windings c) Tank d) Fittings e) Oil f) Total weights of complete transformers with oil and fittings ii) Dimensions a) Overall Height above track b) Overall length c) Overall breadth d) Minimum bay width required for installation of the transformer iii)Weight of the heaviest package of the transformer arranged for transportation 46 Lifting Jacks a) Number of jacks included b) Type and Make c) Capacity d) Pitch e)Lift f)Height in close position 47 Rail Track gauges a) 2 Rails or 4 rails b) Distance between adjacent rails on shorter axis c) Distance between adjacent rails on longer

(mm) (mm) (mm) (mm)

(Kg) (Kg) (Kg) (Kg) (Kg) (Kg)

(mm) (mm) (mm) (mm) (Kg)

(tonnes) (m) (m)

(mm) (mm)

-181Section - IX : Guaranteed & other Technical Particulars