Vous êtes sur la page 1sur 18

STT 3000 Series STT250

Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010
Introduction
Honeywells STT 3000 family of microprocessor based smart temperature transmitters includes both the Series STT250 described in this specification sheet and the higher performance STT350 described in Product Specification Sheet EN0I-5222. The STT350 offers high performance and advanced functionality. The STT250 units offer competitive performance in a more compact module and with a wider range of smart communications protocols. STT25H with HART protocol when this popular protocol is preferred. Configuration of the HART unit can be made with any of the listed HART Communication Foundation tools. STT25S with HART 6 protocol and TUV SIL 2 approval. Configuration of the HART unit can be made with any of the listed HART tools STT25M for 4-20mA operation and local/ remote configuration via Honeywells digital DE protocol from the Smart Field Communicator (SFC) or Smart Configuration Toolkit PC based software (SCT). STT25D with digital DE protocol for either 4-20mA operation or digital integration into the TDC 3000/ TPS 3000 control system. Note that the latest addition to the STT250 family is the Dual Input STT25T. The two sensor inputs may be used for sensor cross checking or for sensor redundancy. This is described in separate Product Specification Sheet EN0I-6091. All units support the same wide range of primary sensor types, are 2 wire powered and give an output linerarized to temperature over the 2 power wires. Lead wire compensation is provided for RTD (Resistance Temperature Detectors) and internal digital cold junction compensation is provided for Thermocouples,.Millivolt and Ohms sensor inputs can also be accepted. Smart communication protocols available include HART or DE Honeywell. Direct sensor head mounting in DIN Form A housing. Housing materials available include plastic, aluminum, 316SS and cast iron. Mounting options include wall, pipe, DIN rail or direct sensor head mounting with or without a housing. Single model accepts input signal from a wide choice of primary sensors to satisfy varying application requirements with minimum transmitter inventory. Suitable for 4, 3 or 2 wire Pt100 and Pt200 RTD measurement. Hard wired upscale/ downscale failsafe link to ensure secure operation in the event of a failure. Open circuit sensor analysis carried out in every measurement cycle. Selectable latching/non-latching failsafe operation for open circuit sensor. Integral analogue or digital indication meter option. Analogue to Digital converter validated frequently

Features

ST 3000 Smart Pressure Transmitter

Description
The STT250 transmitters are suitable as replacements for any conventional or most smart temperature transmitters in use today. The memory contains the characteristics of most commonly used temperature sensors. You can easily use the hand held communicator or PC tool to configure the transmitter for any of these sensors and it will automatically correct for their associated non-linearitys. Accuracies stated below are available merely by selecting the sensor type and range (i.e. without user calibration). Calibration of the LRV/URV end points will typically give accuracy improvements of 2 times. Sensor errors can be calibrated out by calibration to the specific sensor either by having it at the LRV/URV temperatures or by simulation of the known values. In addition, all units pass through Environmental Stress Screening by fast cycling between -40C and +85C to ensure maximum product reliability. During this process the ambient temperature coefficients are determined for each unit and burned into memory to ensure temperature compensation over a wide range of operating conditions. Configuration adjustments and diagnostics checks can be made either locally or remotely over the signal wires from anywhere along their route. This enables major savings in manpower time during commissioning, start up and maintenance activities.

Performance Under Rated Conditions


Sensor Digital Accuracy over Normal Range D/A Accuracy % of span 0.025% 0.025% 0.025% 0.025% 0.025% 0.025% 0.025% 0.025% 0.025% 0.025% 0.025% 0.025% 0.025% Digital Accuracy over Maximum Range Standards

C
Pt100 Pt200 Pt100J mV B E J K N R S T 0.15C for -200 to 450 0.30C for -200 to 450 0.15C for -200 to 450 0.40 for 0 to 1000 15V for -20 to 120mV

(F)

C
0.25C for -200 to 850C 0.40C for -200 to 850C 0.25C for -200 to 640C 0.40 for

(F) (-328 to 1562) (-328 to 1562) (-328 to 1184) IEC751(ITS-90)(=0.00385) IEC751(ITS-90)(=0.00385) JISC1604-81(=0.00392)

(-328 to 842) (-328 to 842) (-328 to 842)

0 to 2,000 *

15V for -20 to 120mV 3.0C for 200 to 1,820C 0.60C for -200 to 1,000C 0.70C for -200 to 1,200C 0.90C for -200 to 1370C 1.5C for -200 to 1300C 1.0C for -50 to 1760C 1.0C for -50 to 1760C 0.5C for -250 to 400C (392 to 3308) (-328 to 1832) (-328 to 2192) (-328 to 2498) (-328 to 2372) (-58 to 3200) (-58 to 3200) ( -418 to 752) IEC 584-1(ITS-90) IEC 584-1(ITS-90) IEC 584-1(ITS-90) IEC 584-1(ITS-90) IEC 584-1(ITS-90) IEC 584-1(ITS-90) IEC 584-1(ITS-90) IEC 584-1(ITS-90)

1.0C for 550 to 1820 (1022 to 3308) 0.30C for 0 to 1000 0.30C for 0 to 800 (32 to 1832) (32 to 1472)

0.60C for -120 to 1370 (-191 to 2498) 0.40C for 0 to 1300 (32 to 2372)

0.60C for 500 to 1760 (932 to 3200) 0.60C for 500 to 1760 (932 to 3200) 0.30C for -100 to 400 (-148 to 752)

* * 4 wire ohms input only and limited to 0 to 1,000 Ohms for model STT25D

ST 3000 Smart Pressure Transmitter

Specifications
Operation Conditions
Parameter Ambient temperature C Humidity Rack mounted % RH In field housing % RH Supply voltage Output current Load resistance Vibration Shock 10 to 55 10 to 55 5 to 95 5 to 100 5 to 100 5 to 100 5 to 100 5 to 100 Reference Condition 23 C 2 Rated Condition -40 to +85 Operative Limits -40 to +85 Transportation And Storage -50 to +100

Voltage range 10.8 to 35 Vdc at the transmitter terminals Current over range 3.8 to 20.8 mA. Failsafe limits < 3.8 and 21.8 mA 0 to 1110 Maximum of 4g over 15 to 200Hz (restricted to 3g with indication meter). Maximum of 40g.

Performance Specifications

Output D/A accuracy: 0.025% of span Cold Junction accuracy: 0.5C Total reference accuracy: Analogue 420mA mode = Digital accuracy + Output D/A accuracy + CJ accuracy (T/Cs only) Total reference accuracy: Digital DE mode = Digital accuracy + CJ accuracy (T/Cs only). (example: transmitter operating in analogue mode with Pt100 sensor and 0 to 200C range. Total reference accuracy = 0.15+(200/100)*0.025 = 0.2C. Digital ambient temperature effect (per 10C change from 23C ref.): RTDs or Ohms : 0.050% of reading in Ohms. : T/Cs or mV : 0.080% of reading in mV. Output D/A ambient temp. effect (per 10C change from 23C ref.): 0.045% of span. Cold Junction ambient temperature effect: 40: 1 rejection for ambient temperature changes from 23C reference. Total Reference Accuracy (Reference Includes combined effects of linearity, hysteresis, and repeatability)

Output update time 0.5 secs approximately. Input/ output galvanic isolation Withstands 500Vac dielectric strength test for 1 minute. Sensor open circuit Open circuit/ burnout detection is user selectable. Upscale or downscale with critical status message. Latching or non-latching sensor burnout action. Common mode rejection 120dB (1 million to 1) from 50Hz to 50 kHz. Output: 4-20mA or Honeywell digital DE protocol. HART and DE available Series mode rejection 40dB (100 to 1) for 50 or 60Hz with 4-20mA output. 0.5Hz. (with internal software filter Adjustment range: No limits to set to local power line frequency). adjustments within the Maximum Range except minimum span limit of 1 EMC compliance In compliance with2004/108/EC, engineering unit e.g. 1C Electromagnetic Compatibility (EMC) Damping time constant: Adjustable Directive. from 0 to 102 seconds digital damping. Radiated RF Immunity: 0.15% of Output response time: 1 second to reach 63% of final value span at 10V/m over 80 to 1,000MHz. with 0 secs damping.

Total output ambient temperature effect : Analogue 4-20mA mode = Digital effect + Output D/A effect + CJ effect (T/Cs only). Total output ambient temperature effect: Digital DE mA mode = Digital effect + CJ effect (T/Cs only). Power supply voltage effect: 0.005% of Max span per Volt. Stability/time drift: 0.05% of max span per year. Additional Parameters

ST 3000 Smart Pressure Transmitter

Physical Mounting and Construction

The STT250 Temperature Transmitter is designed to be mounted in a DIN Form A housing for direct installation with the temperature sensor or can be provided in a remote pipe or wall mount housing. Details for the various housings available are referenced in the table below. The STT250 Temperature Transmitter module can also be DIN rail mounted to a top hat or G rail via a clip. Integral meters available

Integral Meters

Honeywells Series STT250 Temperature Transmitters can be supplied with local or remote indication. An Analogue, Engineering Units or a Smart meter can be mounted integral to the transmitter inside the field mount housing. Order an integral meter as part of the model number; Table II _ _ M, _ _ E and _ _ S, respectively. Order a remote meter as model RMA300. The analogue meter is a 4-20mA moving coil type and displays the temperature in 0 to 100% span. The E. U. meter displays temperature in engineering units with the STT25H, STT25T and STT25S HART units. Refer to 34-ST-25-08D for more details. The Smart meter accepts 4-20mA or DE protocol and displays temperature on a LCD in engineering units or 0 to 100% span. The remote digital meter reads DE protocol and displays temperature on a LCD in 0 to 100% span. Refer to 34ST-25-07A for details.

STT250 Module Dimensions (in/mm)


52

29.2

50

33

STT250 Connections

White

White
RTD

White
RTD

White

+
RTD

Red

Red

Red

Red 2 wires RTD or 2 wires ohm 3 wires RTD or 3 wires ohm Red 4 wires RTD or 4 wires ohm

Single T/C

Materials of Construction Terminal Block Connection Screws Module Housing Weight Noryl M3 Nickel plated brass Cycoloy (PC/ABS) with metallized interior surface 0.075 kg (0.2 lbs)

ST 3000 Smart Pressure Transmitter

Approvals The STT250 Temperature Transmitter module is Intrinsically Safe to ATEX, IECEx , SAEx, FM and CSA standards when used with a suitable safety barrier. It is zone 2 and explosion-proof to ATEX, IECEx, SAEx, FM and CSA standards when installed in a suitable housing. See the Model Selection Guide Table VII in this Specification Sheet for detailed safety approvals covering both the STT250 module only or for the STT250 module supplied in a housing Probe and Thermo well Availability STT250 can be supplied complete with a wide range of thermo wells, thermocouples or RTD sensors. See documents listed in the table below. STT820 Series STT830 Series STT840 Series 34-44-16-08 34-44-16-09 34-44-16-10 Rigid Probe Assemblies. Threaded and Socket Weld Thermo well Assemblies with Transmitter Option. Drilled Flange Thermo well Assemblies

ST 3000 Smart Pressure Transmitter

Model Selection Guides are subject to change and are inserted into the specifications as guidance only. Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at: http://hpsweb.honeywell.com/Cultures/en-US/Products/Instrumentation/ProductModelSelectionGuides/default.htm Model Selection Guide

ST 3000 Smart Pressure Transmitter

ST 3000 Smart Pressure Transmitter

ST 3000 Smart Pressure Transmitter

10

ST 3000 Smart Pressure Transmitter

ST 3000 Smart Pressure Transmitter

11

This page has been intentionally left blank

12

ST 3000 Smart Pressure Transmitter

For More Information Learn more about how Honeywells STT3000 Smart Temperature Transmitters can increase performance, reduce downtime and decrease configuration costs, visit our website www.honeywell.com/ps or contact your Honeywell account manager. Automation & Control Solutions Process Solutions Honeywell 2500 W. Union Hills Dr. Phoenix, AZ 85027 Tel: 877.466.3993 or 602.313.6665 www.honeywell.com/ps
EN0l-6031 March 2010 2008-10 Honeywell International Inc.

Honeywell
Housings for STT 3000 Series STT250
SMART TEMPERATURE TRANSMITTER
EN0I-6032 01/98
OVERVIEW
Honeywells STT250 range of Temperature Transmitters can be supplied with a wide variety of enclosures for direct sensor head, 2 pipe or wall mounting. Available materials include Aluminium, Plastic, Cast Iron and 316 Stainless Steel. Select the most suitable housing for lowest installed cost, lightweight, corrosive environments or for safety approvals - whichever is most important to match your requirements.

Housing Specifications and Dimensional Drawings

All the housings for direct For FM or CSA Explosion-Proof If the temperature transmitter is sensor head mounting include applications, choose the pipe or wall mounted, a housing the facilities for spring loading Aluminium or 316 SS field can be supplied with a sensor of the STT250 transmitter mount housing. and a terminal block installed module at a 33mm pitch (DIN for connection to the remote 43729). mounted transmitter. The housings can be supplied When integral meter is Order sensor and thermowells with the STT250 transmitter required, choose the pipe or for this direct sensor head installed by specifying from the wall (field) mount housing. mounting by referring to STT250 Model Selection Guide Specification EN0I-6033 (nonincluded in Sales Specification For Flame-Proof EEx d North America) and 34-44-29Sheet EN0I-6031. applications, choose the Cast 01 (North America). Iron housing and ensure that the sensor connection is sealed with an approved flametrap by ordering the sensor assembly with the transmitter and housing.

Housing Specifications (in mm)


Aluminium Direct Head Mount Housing
Suitable for general purpose or Intrinsically Safe applications. Dimensions shown in Fig. 1. Housing entry length = 41 mm Material : LM24 Aluminium die casting. Sensor entry : 1/2NPT Cable / conduit entry : 1/2NPT or M20x1.5. Weight : 0.3kg (0.7 lb) Paint cover : beige polyester/ epoxy hybrid. Enclosure classification : IP65 Order as STT250 Table II selection A _ _.
1/2" NPT or M20
33

40 2 x M3
2 x M4

41

1/2" NPT

B-B section Figure 1

A-A section

Plastic Direct Head Mount Housing


Suitable for lightweight installation in salt air environments and for general purpose or Intrinsically Safe installations. Maximum temperature = 70 C (158 F) Dimensions shown in Fig. 2. Housing entry length = 26,5 mm Material : ABS Sensor entry : 1/2BSP (equivalent to 1/2NPT) Cable/ conduit entry : M20x1.5 Colour : light beige Weight : 0.1kg (0.2 lb) Enclosure classification : IP67 Order as STT250 Table II selection P _ _.
33

A
85

2 x M4
26.5

1/2" NPT

C-C section Figure 2

A-A section

Cast Iron Direct Head Mount Housing


Suitable for Flame-Proof EEx d applications when sensor with flame trap is included in total assembly. Dimensions shown in Fig. 3. Housing entry length = 41 mm Material : Cast Iron Sensor entry : 1/2NPT Cable/ conduit entry : M20x1.5 paint cover : light beige Weight : 2.5kg (5.5 lb) Enclosure classification : IP68 Conforms to the applicable requirements of NEMA 7 and 9. Order as STT250 Table II selection B _ _.
33 2 x M4

104)

2 x M4
1/2" NPT or M20 1/2" NPT

B-B section Figure 3

41

111

A-A section

EN0I-6032

1/2" NPT or M20

57

316 Stainless Steel Direct Head Mount Housing


Suitable for corrosive/ salt spray environments and for general purpose or Intrinsically Safe applications. Dimensions shown in Fig. 4. Housing entry length = 40 mm Material : 316SS Sensor entry : 1/2NPT Cable/ conduit entry : 1/2NPT or M20x1.5 Paint cover : none. Weight : 1.6kg (3.5 lb) Enclosure classification IP65 Order as STT250 Table II selection S _ _. Flame-Proof version available.

33
100

2 x M4

80

40

1/2" NPT

B-B section Figure 4

A-A section

Meters
Honeywells Series STT250 Temperature Transmitters can be supplied with local or remote indication. An Analogue or Smart meter can be mounted integral to the transmitter inside the field mount housing. Order an integral meter as part of the model number; Table II _ _ M and _ _ S, respectively. Order a remote meter as model RMA300. The analogue meter is a 4-20mA moving coil type and displays the temperature in 0 to 100% span. The Smart meter accepts 4-20mA or DE protocol and displays temperature on a LCD in engineering units or 0 to 100% span. The Smart meter displays temperature in 0 to 100% span with the STT25H HART unit. Refer to 34-ST25-08D for more details. The remote digital meter reads DE protocol and displays temperature on a LCD in 0 to 100% span. Refer to 34-ST-2507A for details.

STT250 Dimensions
Aluminium Pipe or Wall (Field) Mount Housing
Suitable for pipe or wall mounting remote from the temperature sensor, for direct sensor head mounting (in North America), for local indication and for Explosion-Proof (FM/ CSA and Cenelec), Intrinsically Safe or general purpose applications. Dimensions shown in Fig. 5 and 6. Material : Low copper Aluminium alloy Cable/ Conduit entries : 1/2NPT. Paint cover : Beige polyester/ epoxy hybrid or beige epoxy painted. Weight : 1.1kg (2.4 lb) Enclosure classification : IP65. Conforms to the applicable requirements of NEMA 7and 9 for FM/ CSA Explosion-Proof applications. Order as STT250 Table II selection E _ _ or X _ _, respectively.

316 Stainless Steel Pipe or Wall (Field) Mount Housing


Suitable for corrosive/ salt spray environments and for pipe or wall mounting remote from the temperature sensor, for direct sensor head mounting (in North America), for local indication and for Explosion-Proof (FM/ CSA and Cenelec), Intrinsically Safe or general purpose applications. Dimensions shown in Fig. 5 and 6. Material : 316SS Cable/ Conduit entries : 1/2NPT. 3/4 NPT or M20 available via an adaptor. Paint cover : none. Weight : 3.2 kg (6.9 lb) Enclosure classification : IP65 Order as STT250 Table II selection T _ _.

EN0I-6032

1/2" NPT or M20

Dimensions in Figures 5 and 6 Without integral meter With integral meter

Aluminium Field Mount Housing A B 70 mm 120.8 mm 2.76 inch 4.76 inch 127 mm 210.8 mm 5.00 inch 8.30 inch

316 Stainless Steel Field Mount Housing A B 95.5 mm 146.3 mm 3.76 inch 5.76 inch 127 mm 210.8 mm 5.00 inch 8.30 inch

A B

A B

With meter

Without meter

142 (5.59) 40 (1.57)


OPTIONAL 316 SS WIRED ON TAG

59.5 (2.34)

PROCESS/SENSOR ENTRY : 1/2" NPT OPTIONAL M20 OR 3/4" NPT ADAPTOR

PANEL CABLE/CONDUIT ENTRY 1/2" NPT OPTIONAL M20 OR 3/4" NPT ADAPTOR PROVIDE 2 BOLTS AND NUTS M8 TO THE FIXATION

60 (2.36)

FIELD MOUNT HOUSING

115 (4.53)

94 (3.7)

Figure 5 - STT250 Wall Mounting Dimensions

EN0I-6032

A B CLEARANCE FOR CAP REMOVAL


B

CLEARANCE FOR CAP REMOVAL

With meter

Without meter

142 (5.59)

14.9 (0.59)

40 (1.57)

191.5 (7.54)

61.8 (2.43)

OPTIONAL 316 SS WIRED ON TAG OPTIONAL MOUNTING BRACKET FOR 2" PIPE CABLE/CONDUIT ENTRY 1/2" NPT OPTIONAL M20 OR 3/4" NPT ADAPTOR FIELD MOUNT HOUSING

PROCESS/SENSOR ENTRY : 1/2" NPT OPTIONAL M20 OR 3/4" NPT ADAPTOR

39 (1.54)

60 (2.36)

14.9 (0.59)

94 (3.7) 115 (4.53) 129.5 (5.1)

Figure 6 - STT250 Pipe Mounting Dimensions

29.2 (1.15)

36.7 (1.44)

39.2 (1.56)

G DIN RAIL

TOP HAT / DIN RAIL

EN0I-6032

TOP HAT /

DIN RAIL

33 (1.3)
"G" DIN RAIL

24.1 (0.95)

Optional DIN rail clip

STT250

52 (2.05)

STT250 MODULE

INSTALLATION WITH DIN RAIL

Figure 7 - STT250DIN Rail Mounting Dimensions

Distributor :

Honeywell
Industrial Automation and Control Honeywell Inc.
In the U.S.A.: In Europe:

Helping You Control Your World

Honeywell Industrial Automation and Control, 16404 North Black Canyon Hwy., Phoenix, AZ 85023, (602) 313-5000 Honeywell Pace, 1 Avenue du Bourget, B-1140 Brussels, Belgium, (32-2) 728-211 Honeywell S.A., Zone Industrielle de Longpr, F-80084 Amiens Cdex 2, France, (33-3) 22-54-56-56 In Asia: Honeywell Asia Pacific Inc., N 19, Toa Payoh, Lorong 8 #06-00, Singapore 1231, 354-6768 In the Mediterranean: Africa & Middle East Region, Honeywell SpA, Via Vittor Pisani 13, 20124 Milano, Italy, (39-2) 67731 In Canada: The Honeywell Centre, 155 Gordon Baker Rd., North York, Ontario M2H 3N7, 1-800-461-0013 In Latin America: Honeywell Inc., 14505 Commerce Way, Suite 500, Miami Lakes, Florida 33016-1556, (305) 3642300