l l l l

E-UTRAN: Evolved UMTS Terrestrial Radio Access Network EPC: Evolved Packet Core network MME: Mobility Management Entity S-GW: Server Gateway Functions of NEs eNodeB p Radio resource management, including radio bearer control, radio admission control, connection mobility control, and scheduling p Packet compression and ciphering p Routing of user plane data towards an S-GW p MME selection p Scheduling and transmission of broadcast information and paging messages p Measurement and measurement reporting configuration MME p Paging message distribution p Security control p Mobility management in idle mode p SAE bearer control p Ciphering and integrity protection of Non-Access Stratum (NAS)signaling S-GW p Termination of user plane packets that are generated for paging reason p Support for user plane handovers caused by UE mobility

l l

Confidential Information of Huawei. No Spreading Without Permission

Page 4 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:03 PM

eNodeB LTE TDD V100R004 Product Description

eNodeBs are designed based on a distributed architecture. Each eNodeB consists of two basic types of component: baseband unit BBU3900 and Radio Frequency (RF) unit RRU or RFU.

Confidential Information of Huawei. No Spreading Without Permission

Page 5 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:03 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 6 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:03 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 7 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:03 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 8 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:04 PM

eNodeB LTE TDD V100R004 Product Description

The BBU3900 implements OM management, signaling processing, and radio resource management of the entire eNodeB system and provides ports for data communication between the eNodeB and the MME/S-GW. The BBU3900 performs the following functions: p Provides ports for data communication between the eNodeB and the MME/SGW. p Provides CPRI (Common Public Radio Interface) ports for communication between the BBU3900 and the RRUs. p Provides USB ports, which facilitate eNodeB upgrade when a USB disk is inserted into the LMPT during software installation and data configuration. p Provides the OM channel for connection to the M2000. p Processes uplink and downlink data. p Manages the entire eNodeB system in terms of OM and signaling processing. p Provides ports for the system clock. p Provides ports for alarm monitoring. The BBU3900 features a compact case structure that only requires a 19-inch-wide and 2 U-high space. It can be installed on an indoor wall, on the staircase, in the storeroom, or in an outdoor cabinet of the existing network. The BBU3900 is configured with the following basic hardware units: p LTE Main Processing & Transmission unit (LMPT) p LTE BaseBand Processing unit (LBBP) p Fan module, that is, FAN p Power module, that is, Universal and Environment interface Unit (UPEU) Confidential Information of Huawei.Power No Spreading Without Permission

Page 9 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:04 PM

eNodeB LTE TDD V100R004 Product Description

LMPT The LTE Main Processing&Transmission Unit (LMPT) is the main control and transmission unit of the BBU3900. It manages the entire eNodeB in terms of OM and signaling processing and provides clock signals for the BBU3900. LBBP The LTE Baseband Processing Unit (LBBP) is the baseband processing unit of the BBU3900. It processes baseband signals and CPRI signals. FAN The FAN module controls the fan speed and monitors the temperature of the module. It dissipates heat for boards and modules of the BBU3900. UPEU The Universal Power and Environment interface Unit (UPEU) is the power module of the BBU3900. It converts +24 V DC or -48 V DC power into the power required for boards and modules of the BBU3900 and provides ports for transmission of external monitoring signals and eight dry contact signals.

Confidential Information of Huawei. No Spreading Without Permission

Page 10 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:04 PM

eNodeB LTE TDD V100R004 Product Description

Control Subsystem : The functions of the control subsystem are implemented by the LMPT. This subsystem performs OM functions, processes signaling, and provides the system clock. It manages the entire eNodeB p The OM functions include configuration management, fault management, performance management, security management, and deployment. p The signaling involves Packet Data Convergence Protocol (PDCP) signaling on the Uu interface and Stream Control Transmission Protocol (SCTP) signaling on the S1 and X2 interfaces. p The system clock can be one of the following types: Global Positioning System (GPS), IEEE1588 V2, synchronous Ethernet, or Clock over IP Transport Subsystem : The functions of the transport subsystem are implemented by the LMPT and UTRP p Provides ports for communication between the eNodeB and the EPC p Provides the OM channel between the eNodeB and the Local Maintenance Terminal (LMT) or M2000 p Provides ports for communication between the eNodeB and 2G/3G base stations so that the E1/T1 transmission resources can be shared by the eNodeB and the 2G/3G base stations

Confidential Information of Huawei. No Spreading Without Permission

Page 11 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:04 PM

eNodeB LTE TDD V100R004 Product Description

Baseband Subsystem : The functions of the baseband subsystem are implemented by the LBBP. The baseband subsystem performs the functions for the user plane of the Uu interface, including uplink and downlink scheduling and data processing. In addition, this subsystem provides the Common Public Radio Interface (CPRI) for communication between the BBU3900 and Radio Frequency (RF) units p According to the indication of uplink scheduling result, the uplink processing module receives data over uplink channels, demodulates and decodes the data, assembles the data into packets, and then transmits the data to the MME or SGW through the transport subsystem. In addition, the module performs measurements on uplink channels. p According to the indication of downlink scheduling result, the downlink processing module assembles the data received from the transport subsystem into packets, encodes and modulates the data, performs Multiple Input Multiple Output (MIMO) and Orthogonal Frequency Division Multiplex (OFDM) processing, and then transmits the signals over the CPRI interface. p The CPRI interface is used for transmission of data between the BBU3900 and RF units Power and Environment Monitoring Subsystem :The functions of the power and environment monitoring subsystem are implemented by the UPEU and environment monitoring unit p Supplies power to the BBU3900. p Monitors the power status of the BBU3900. p Provides ports for connections to the environment monitoring unit and receives and forwards the signals from the environment monitoring unit

Confidential Information of Huawei. No Spreading Without Permission

Page 12 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:04 PM

eNodeB LTE TDD V100R004 Product Description

Ports on the LMPT


Label Connector Type Quantity Function

SFP 0 and SFP 1 USB TST ETH

LC

Ethernet optical port, used for connecting Transmission equipment or gateway Equipment Used for loading software to the board. Used for testing. Used for local commissioning. Ethernet electrical port, used for connecting Transmission equipment or gateway Equipment Used for receiving GPS signals. Used for resetting the BBU3900.

USB USB RJ-45

1 1 1 2 1 1

FE/GE0 and RJ-45 FE/GE1 GPS RST SMA -

Confidential Information of Huawei. No Spreading Without Permission

Page 13 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:04 PM

eNodeB LTE TDD V100R004 Product Description

Ports on the LBBP


Label CPRI0 to CPRI5 Connector SFP female Quantity Description 6 The CPRI ports connect to the LRRUs or LRFUs for transmitting service data, clock signals, and synchronization information

Label Color TX RX

LEDs for the ports of the LBBP


Status Red/G Steady green reen Steady red

Description The CPRI link is available. The optical module may fail to send or receive signals. (The failure may be caused by a faulty optical module or disconnected optical fiber.)

Blinking red (on for The RRU in the CPRI link has a hardware fault. 0.125s and off for 0.125s) Blinking red (on for The CPRI link is out of lock (The fault may be caused by mutual lock 1s and off for 1s) of dual-mode clock sources or mismatched data rate over CPRI interfaces, and you are advised to check the system configuration) or the VSWR alarm is reported on the RRUs in the CPRI link (because the USB storage disk is under test). Off The SFP module is not in position or the optical module is powered off.

Confidential Information of Huawei. No Spreading Without Permission

Page 14 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:04 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 15 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:04 PM

eNodeB LTE TDD V100R004 Product Description

LEDs on the FAN module


LED Color Status Blinking at 4 Hz (ON for 0.125s and OFF for 0.125s) Blinking at 0.5 Hz (ON for 1s and OFF for 1s) Red ON Description The module is not registered and does not report alarms. The module works properly. The module is reporting alarms.

Green STATE

Confidential Information of Huawei. No Spreading Without Permission

Page 16 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:04 PM

eNodeB LTE TDD V100R004 Product Description

The UPEU is classified into three types: Universal Power and Environment Interface Unit Type A (UPEUa), Universal Power and Environment Interface Unit Type B (UPEUb), and Universal Power and Environment Interface Unit Type C (UPEUc). The UPEUa and UPEUc convert -48 V DC power into +12 V DC, and the UPEUb converts +24 V DC power into +12 V DC. LED on the panel of the UPEU
Label RUN Color Green State On Off Meaning The UPEU is working properly. The board is powered on but is faulty.

Slot Label Connector Description on the ports Slot 19 +24 V or -48 V 3V3 EXT-ALM0 RJ-45 EXT-ALM1 RJ-45 MON0 RJ-45 MON1 RJ-45 Slot 18 +24 V or -48 V 3V3 EXT-ALM0 RJ-45 EXT-ALM1 RJ-45 MON0 RJ-45 MON1 RJ-45

Quantity 1 1 1 1 1 1 1 1 1 1

Description Introducing +24 V DC or -48 V DC power Port for Boolean inputs 0 to 3 Port for Boolean inputs 4 to 7 Port for RS485 input 0 Port for RS485 input 1 Introducing +24 V DC or -48 V DC power Port for Boolean inputs 0 to 3 Port for Boolean inputs 4 to 7 Port for RS485 input 0 Port for RS485 input 1

Confidential Information of Huawei. No Spreading Without Permission

Page 17 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:04 PM

eNodeB LTE TDD V100R004 Product Description

Ports on the UEIU


Label EXT-ALM1 EXT-ALM0 MON1 MON0 Connector Type RJ-45 RJ-45 RJ-45 RJ-45 Function No.4 to 7 Boolean signal input ports No.0 to 3 Boolean signal input ports Used to provide transmission of one RS485 monitoring signal Used to provide transmission of one RS485 monitoring signal

Confidential Information of Huawei. No Spreading Without Permission

Page 18 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 19 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

Ports on UTRP
Label Port Quantity Connector

E1/T1

E1/T1

DB26 connector

Confidential Information of Huawei. No Spreading Without Permission

Page 20 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

Ports on USCU
Port 1. GPS 2. RGPS 3. TOD0 3. TOD1 4. M1PPS 5. BITS Connector SMA coaxial connector PCB welded wiring terminal RJ-45 RJ45 SMA coaxial connector SMA coaxial connector Receives GPS signals Receives RGPS signals Receives or transmits 1PPS+TOD signals Receives or transmits 1PPS+TOD signals, and receives TOD signals from the IP clock server Receives 1PPS signals from the Metro1000 Receives BITS clock signals and supports adaptive input of 2.048 MHz and 10 MHz clock reference source Description

Confidential Information of Huawei. No Spreading Without Permission

Page 21 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 22 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

l l l l

RRU3231: for India project RRU3232 and RRU3233: for China Mobile project RRU3235: for Japan project RRU3236: for Japan project, now is pending.

Confidential Information of Huawei. No Spreading Without Permission

Page 23 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

l l

The RRU3211 is a type of remote radio unit supporting the TDD mode(2T2R). The RRU3211 implements the following functions: p Performs low noise amplification and down-conversion for the signals received from the antenna, performs analog-to-digital conversion, digital downconversion, filtering, and Automatic Gain Control (AGC) for the received analog Intermediate Frequency (IF) signals, and then transmits the processed baseband digital signals to the baseband unit through the high-speed transmission link. p Receives downlink baseband data from the BBU, preforms matched filtering, digital upconversion,and Crest Factor Reduction (CFR), modulates the Inphase Quadrature (IQ) differential signals to the TX band before amplifying the signals, and sends the signals from the antenna. p Multiplexes RX and TX signals, which enables these signals to share the same antenna path. It also filters RX and TX signals.

Confidential Information of Huawei. No Spreading Without Permission

Page 24 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 25 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

Ports and LEDs on the RRU3211 panel


Item Label ANTA_TX/RX ANTC_TX/RX Bottom panel PGND RET TX RX CPRI0 TX RX CPRI1 RTN0(+) Cabling cavity NEG0(-) panel RTN1(+) NEG1(-) ETH Description Main TX/RX port Diversity TX/RX port PGND port Communication port of the RET antenna Optical port Main power supply socket Power supply socket for cascading RRUs Port for local maintenance

SN

Confidential Information of Huawei. No Spreading Without Permission

Page 26 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description


l

LEDs on the RRU3211


Color Green On Off Blinking (on for 1s and off for 1s) Blinking (on for 0.125s and off for 0.125s) Status Description There is power supply, but the board is faulty. There is no power supply. The board is working properly.

Label RUN

The software is being loaded to the board, or the board is not started. Alarms are generated, and the module needs to be replaced. No alarm is generated. Alarms are reported. The alarms may be caused by the faults of the related boards or ports. Therefore, whether the module needs to be replaced cannot be decided. The RRU is working properly. The software version is being checked or the version check fails. The software version check is successful, but the TX channel is disabled. No VSWR alarm is reported. A VSWR alarm is reported. The CPRI link is available. The RRU is not configured or not communicating with the BBU. The CPRI link is available. The RRU is not configured or does not communicate with the BBU.

ALM

Red

On Off blinking (on for 1s and off for 1s)

TX_ACT

Green

On Off Blinking (on for 1s and off for 1s)

VSWR

Red

Off On

CPRI0

Green

On Off

CPRI1

Green

On Off

Confidential Information of Huawei. No Spreading Without Permission

Page 27 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 28 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

l l

The RRU3233 is a type of radio remote unit supporting the TDD mode(8T8R). The RRU3233 implements the following functions: p Performs low noise amplification and down-conversion for the signals received from the antenna, performs analog-to-digital conversion, digital downconversion, filtering, and Automatic Gain Control (AGC) for the received analog Intermediate Frequency (IF) signals, and then transmits the processed baseband digital signals to the baseband unit through the high-speed transmission link. p Receives the downlink baseband data from the BBU, performs matched filtering, digital up-conversion, Crest Factor Reduction (CFR), modulates the Inphase Quadrature (IQ) differential signals to the TX band before amplifying the signals, and sends the signals from the antenna. p Multiplexes the RX and TX signals, which enables these signals to share the same antenna path. It also filters RX and TX signals.

Confidential Information of Huawei. No Spreading Without Permission

Page 29 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 30 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

Ports and LEDs on the RRU3233 panel


Port Label ANT1-ANTA8 Description TX/RX port RET antenna port

Item (1) Bottom port

RS485/EXT_ALM TX RX CPRI0/IR0

Optical port (2) Cabling cavity port TX RX CPRI1/IR1 RTN(+)0 NEG(-)0 ETH Power port Local maintenance port

Confidential Information of Huawei. No Spreading Without Permission

Page 31 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description


l

LEDs on the RRU3233


Label RUN Color Green Status On Off Blinking (on for 1s and off for 1s) Blinking (on for 0.125s and off for 0.125s) ALM Red On Off Blinking (on for 1s and off for 1s) Description There is power supply, but the board is faulty. There is no power supply, or the board is faulty. The board is working properly. The software is being loaded to the board, or the board is not started. Alarms are generated, and the module needs to be replaced. No alarm is generated. Alarms are reported. The alarms may be caused by the faults of the related boards or ports. Therefore, whether the module needs to be replaced cannot be decided. The board is working properly with the TX channel enabled. The board is working properly with the TX channel disabled. No VSWR alarm is reported. A VSWR alarm is reported. The CPRI link is available. The optical module fails to receive signals. The CPRI link is out of lock. The Small Form-Factor Pluggable (SFP) module is not in position or the optical module is powered off. The CPRI link is functional. The optical module fails to receive signals. The CPRI link is out of lock. The SFP module is not in position or the optical module is powered off.

ACT

Green

On Blinking (on for 1s and off for 1s)

VSWR

Red

Off On

CPRI0/I R0

Red/Gr een

Steady green Steady red Blinking red (on for 1s and off for 1s) Off

CPRI1/I R1

Red/Gr een

On Off Blinking red (on for 1s and off for 1s) Off

Confidential Information of Huawei. No Spreading Without Permission

Page 32 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 33 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:05 PM

eNodeB LTE TDD V100R004 Product Description

STMA (Smart Tower-mounted Amplifier) mode. In this mode, the distance between the RRU and the RCU is longer than 20 m and the TMA is required for the eNodeB. p A command is sent to the BBU on the M2000 or the LMT, and then the BBU transfers that command to the RRU. The RRU transfers the DC power and the OOK (On-Off-Keying ) signals to the STMA from the connector on top of the cabinet. The STMA demodulates the OOK signals to RS485 signals and then supplies the RS485 signals and part of the DC power to the RCU. SBT( Smart Bias-Tee ) mode. In this mode, the distance between the RRU and the RCU is longer than 20 m and the TMA is not required for the eNodeB. p A command is sent to the BBU on the M2000 or the LMT, and then the BBU transfers that command to the RRU. The RRU transfer the DC power and the OOK signals to the SBT from the connector on top of the cabinet. The SBT demodulates the OOK signals to RS485 signals and then supplies the RS485 signals and part of the DC power to the RCU. Direct connection through multi-core cables. In this mode, the distance between the RRU and the RCU( Remote Control Unit ) is shorter than 20 m. p A command is sent to the BBU on the M2000 or the LMT, and then the BBU transfers that command to the RRU. The RRU modulates the command to RS485 signals, and then transfers the signals and the DC power to the RCU through multi-core cables.

Confidential Information of Huawei. No Spreading Without Permission

Page 34 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

In the case, RCU of Huawei and the SBT of Kathrein are configured. The RCU (Remote Control Unit) is the motor drive of the phase shifter inside the electrical antenna. It receives and runs the control commands from the base station and drives the stepper motor. The stepper motor drives the phase shifter inside the antenna device, and the phase shifter adjusts the antenna tilt. Interface RS485 functions as the control interface of the RCU. The SBT (Smart Bias-Tee) provides DC power supply and control commands through the feeder for the RCU. The SBT is installed on the RET antenna side. The SBT provides the following functions: p The SBT converts the control commands that are modulated with OOK by the feeder into the RS485 signals and transfers the signals to the RCU. p The SBT converts the RS485 signals from the RCU into OOK signals and transfers the signals to the feeder. p The SBT divides and sends the RF signals and control signals from the feeder to the antenna and the RCU. p The SBT transmits the direct current from the feeder to the RCU.

Confidential Information of Huawei. No Spreading Without Permission

Page 35 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 36 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

To meet requirements in different outdoor environments, multiple cabinets with different functions are provided by Huawei for distributed macro base stations. The Advanced Power module with heat exchanger (APM30H) provides space and surge protection and enables power distribution and heat dissipation for the BBU3900 and RFU. The Integrated Battery Backup System with direct ventilation (IBBS200D) and Integrated Battery Backup System with TEC cooler (IBBS200T) provides long-duration backup power for a base station. The Transmission Cabinet of 11 U high with heat exchanger (TMC11H) provides space for customer equipment.

Confidential Information of Huawei. No Spreading Without Permission

Page 37 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

l l

The advanced power module APM30 is a power backup system for outdoor applications. It provides the DBS3900 with 48 V DC power and backup batteries. It also provides space for the BBU3900 and customer equipment to facilitate rapid network deployment. With -48V 24Ah build-in batteries:5U space Without build-in batteries:7U space The APM30 can provide the following functions: p DC power supply p Battery management p Power system monitoring p Power distribution p Surge protection p Temperature control p Power backup p Accommodation of customer equipment The APM30, small and light, can be configured with built-in 24 Ah batteries and dissipates heat using a breathable film and fans. The APM30H can be configured in low-air-quality areas. The APM30H dissipates heat using a heat exchanger and outer and inner air circulation fans.

Confidential Information of Huawei. No Spreading Without Permission

Page 38 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

Components in the APM30H cabinet


Optional or Mandatory Max. Configurati on per Cabinet 1 Remarks

Module

1. Fan box

Mandatory

The fan box is configured with the fan, Hert Power Monitoring Interface unit (HPMI), and Central Monitoring Unit type A (CMUA). It is used to dissipate heat in the cabinet. The Signal Lightning Protection Unit (SLPU) is installed in the top 1 U space of the cabinet, providing protection for trunk signals as a mandatory component. The SLPU is configured with the Universal E1/T1 Lightning Protection unit (UELP) or Universal FE Lightning Protection unit (UFLP). The SLPU is an optional component, which is used to protect monitoring signals, is installed in the 1 U space below the BBU. It contains two Universal Signal Lightning Protection unit 2 (USLP2s). The power supply unit (PSU) converts 110 V/220 V AC power into -48 V DC power. The EPS provides functions of AC and DC power distribution for the cabinet. There are two types of EPSs, which are used in 110 V AC and 220 V AC power supply scenarios.

2. SLPU

Mandatory

3. PSU (AC/ DC) 4. EPS subrack

Mandatory

Mandatory

Confidential Information of Huawei. No Spreading Without Permission

Page 39 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

Components in the IBBS200D cabinet


Max. Configurati on per Cabinet 2

Module

Optional or Mandatory

Remarks

1. Fan box

Mandatory

The FAN is installed on the front door of the cabinet, dissipating heat in the cabinet. The CMUA provides functions of temperature control, Boolean alarm detection, and ELU identification of the cabinet. The power distribution box is installed on the upper right of the cabinet, transferring and distributing power to the TEC or fan and to the batteries. The battery provides long-duration backup power for a base station.

2. CMUA 3. Power distribution box 4. Battery

Mandatory

Mandatory

Mandatory

Confidential Information of Huawei. No Spreading Without Permission

Page 40 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

Components in the IBBS200T cabinet


Optional or Mandatory Max. Configurati on per Cabinet Remarks

Module

1. TEC

Mandatory

The TEC is installed in the protecting hood for the TEC on the front door of the cabinet. The TEC consists of the TEC module, inner air circulation fan, outer air circulation fan, heat-dissipation piece, and monitoring board. The CMUA provides functions of temperature control, Boolean alarm detection, and ELU identification of the cabinet. The power distribution box is installed on the upper right of the cabinet, transferring and distributing power to the TEC or fan and to the batteries. The battery provides long-duration backup power for a base station.

2. CMUA 3. Power distribution box 4. Battery

Mandatory

Mandatory

Mandatory

Confidential Information of Huawei. No Spreading Without Permission

Page 41 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

l l l

The TMC can be configured when more space is required for transmission equipment. The cabinet, used outdoors, is small in size and easy to transport. The TMC dissipates heat through a breathable film and fans. The BBU3900 can be installed in the TMC. A TMC can provide a maximum of 11 U space for customer equipment. TMC11H providing space for the transmission equipment, as shown in A TMC11H configured with the BBU3900 in the -48 V DC power supply scenario, as shown in B

Confidential Information of Huawei. No Spreading Without Permission

Page 42 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

When long-term power backup is required, the battery cabinet (BBC) can be configured. The cabinet, used outdoors, is small in size and easy to transport. The BBC dissipates heat in direct-ventilation mode. Configured with built-in battery groups, a BBC can provide a maximum of 48 V DC 184 Ah backup power.

Confidential Information of Huawei. No Spreading Without Permission

Page 43 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

l l l

It can be installed on the ground. It supports the installation of six RRUs. The upper and lower adjustable beams on an IFS06 can be moved up and down to fit for heights of RRUs.

Confidential Information of Huawei. No Spreading Without Permission

Page 44 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 45 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 46 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

A x B MHz indicates that an eNodeB is configured with A cells of B MHz bandwidth. xTyR indicates that each cell uses x TX channels and y RX channels. For example, "3 x 10 MHz, 2T2R" indicates that the eNodeB is configured with three cells of 10 MHz bandwidth, and each cell uses two TX channels and two RX channels.

Confidential Information of Huawei. No Spreading Without Permission

Page 47 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:06 PM

eNodeB LTE TDD V100R004 Product Description

Star topology p Advantage: Each eNodeB is connected directly to the MME through the transport network. Therefore, this simple topology features easy engineering, maintenance, and capacity expansion; Each eNodeB exchanges data with the MME directly. Signals travel through only a few nodes, and therefore network reliability is high p Disadvantage: Compared with the other two topologies, the star topology requires more transmission resources Chain topology & Tree topology p Advantage: The costs of transmission equipment, engineering, and transport line lease are relatively low p Disadvantage: Signals travel through many nodes, and therefore network reliability is low. Each lower-level eNodeB occupies some transmission bandwidth of its upper-level eNodeB. Reliability of the upper-level eNodeB affects operation of the lower-level eNodeB.

Confidential Information of Huawei. No Spreading Without Permission

Page 48 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:07 PM

eNodeB LTE TDD V100R004 Product Description

Star topology p Advantage: This topology features high reliability. Faults in an RRU/RFU or optical cable affect one sector at most. This simple topology facilitates installation and maintenance. p Disadvantage: Compared with the other two topologies, the star topology requires more transmission resources. Chain topology p Advantage: This topology requires relatively low costs of transmission equipment. p Disadvantage: Limitations are applied to the number of levels in a chain and the distance between units in a chain; LRRUs in different duplex modes cannot be cascaded in a chain. A faulty LRRU may affect operation of lower-level LRRUs. p Remarks: Cascading between LRFU and LRRU is not supported. An LRRU chain can contain a maximum of three LRRUs. (Cascading is applicable only when the channel bandwidth is 1.4 MHz, 3 MHz, or 5 MHz.). A chain supports only one rate at a time, because interconnected CPRI ports on two LRRUs in a chain must work at the same rate. Tree topology p Advantage: The ring topology provides high transmission reliability. p Disadvantage: Limitations are applied to the number of levels in a chain and the distance between units in a chain; LRRUs in different duplex modes cannot be cascaded in a chain. A faulty LRRU may affect operation of lower-level LRRUs.
Confidential Information of Huawei. No Spreading Without Permission

Page 49 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:07 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 50 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

6/23/2012 4:39:07 PM

eNodeB LTE TDD V100R004 Product Description

Confidential Information of Huawei. No Spreading Without Permission

Page 51 of 51 PDF created with pdfFactory Pro trial version www.pdffactory.com

Vous aimerez peut-être aussi