EI Manual
EI Manual
Page 3
Table of Contents
EI Front Cover and Drive Assembly................................................................................................................................... 4 Regeneration and Error Screens.......................................................................................................................................... 5 User Displays ...................................................................................................................................................................... 6 Installer Display Settings .................................................................................................................................................... 7 Setting Regeneration Cycle Times ...................................................................................................................................... 9 Congurations Settings ..................................................................................................................................................... 10 Alternator Programming Guide ........................................................................................................................................ 13 Diagnostics........................................................................................................................................................................ 14
Page 4
EI Manual
EI Front Cover and Drive Assembly Drawing No. 1 2 3 4 5 6 Order No. V3175EI-01 V3107-01 V3106-01 V3408EI-02BOARD V3110 V3109 V3186 V3186EU V3186UK V3186-01 V3178 Description WS1EI FRONT COVER ASSEMBLY WS1 MOTOR WS1 DRIVE BRACKET & SPRING CLIP WS1THRU2L EI PCBRD MAV/ALT REPL WS1 DRIVE REDUCING GEAR 12X36 WS1 DRIVE GEAR COVER WS1 AC ADAPTER 110V-12V WS1 AC ADAPTER 220-240V-12V EU WS1 AC ADAPTER 220-240V-12V UK WS1 AC ADAPTER CORD ONLY WS1 Drive Back Plate Quantity 1 1 1 1 3 1
Not Shown
Not Shown
Refer to Control Valve Service Manual for other drawings and part numbers. AC Adapter Supply Voltage Supply Frequency Output Voltage Output Current
When replacing the battery, align positives and push down to fully seat. Correct Battery Orientation Battery Fully Seated Battery replacement is 3 volt lithium coin cell type 2032.
4 1 6 5
EI Manual
Page 5
Regen Screen
Displays the time remaining in the current cycle. Pressing REGEN advances to the next cycle.
Error Screen
Alternated ashing Err and error code every 3 seconds. Clear by dissconnecting the power supply at the PC board and reconneting, or press the NEXT and REGEN buttons simutaneously for 3 seconds.
Pressing once and releasing will schedule a regeneration at the preset delayed regeneration time. Pressing again and releasing will cancel the regeneration. Pressing and holding for 3 seconds will initiate an immediate regeneration Pressing while in regeneration will advance to the next cycle. Pressing in the program levels will go backwards to the previous screen Changes variable being displayed.
Holding for 3 seconds intitiates a control reset. The software version is displayed and the piston returns to the home/service position, resynchronizing the valve.
Page 6
EI Manual
User Displays
General Operation
When the system is operating, one of ve displays may be shown. Pressing NEXT will alternate between the displays shown below.
User 1
Typical user display. If volume is selected in Conguration Settings Step 3CS, shows volume remaining to regeneration. If volume is not selected in Conguration Settings Step 3CS, this screen will not be shown. If a meter is not used this display will not change.
User 2
Displays number of days to next regeneration.
User 3
Displays ow rate M3/Hour. If a meter is not used this display will be shown but 0 will be displayed.
User 4
Displays total ow in cubic meters since last reset. If a meter is not used this display will be shown but 0 will be displayed. PRESS THE DOWN ARROW FOR 3 SECONDS TO RESET TO 0.
User 5
Shows current time.
EI Manual
Page 7
Step 1I - To enter Installer Display press the NEXT and buttons simultaneously for 5 seconds and release. Step 2I - Volumetric capacity in cubic meters to regeneration. Press NEXT to go to Step 3I. Press REGEN to exit Installer Display.
Step 2I
Step 3I
Step 3I - Adjust day override from 1 - 28 or OFF. Press NEXT to go to Step 4I. Press REGEN to return to previous step.
Step 4I
Step 4I - Use or buttons to set the regen hour. Press NEXT to go to Step 5I. Press REGEN to return to the previous step.
Step 5I
Step 5I - Use or buttons to set the regen minutes. Press NEXT to exit Installer Display. Press REGEN to return to previous step.
Step 1I - To enter Installer Display press the NEXT and buttons simultaneously for ve seconds and release.
Step 2I
Step 2I - Adjust days from 1 - 28. Press NEXT to go to Step 3I. Press REGEN to exit Installer Display.
Step 3I
Step 3I - Use or buttons to set time of the regen hour. Press NEXT to go to Step 4I. Press REGEN to return to previous step.
Step 4I
Step 4I - Use and buttons to set the regen minutes. Press NEXT to exit Installer Display. Press REGEN to return to previous step.
Page 8
EI Manual
Step 1I - To enter Installer Display press the NEXT and buttons simultaneously for 5 seconds and release. Step 2I - Use or buttons to set the current day of
the week.
Default = 2 (Monday) 1 = SUNDAY 2 = MONDAY 3 = TUESDAY 4 = WEDNESDAY 5 = THURSDAY 6 = FRIDAY 7 = SATURDAY
Step 2I
Step 3I - Scroll through days 1 to 7 using the NEXT button. Use the or buttons to turn regen on or off for each individual day (regen indicator on means regeneration will happen). After completing the 7th day, press NEXT to go to Step 4I. Press REGEN to go to previous display.
Step 4I
Step 4I - Use the or buttons to set the regen hour. Press NEXT to go to Step 5I. Press REGEN to go to previous display.
Step 5I
Step 5I - Use the or buttons to set the regen minutes. Press NEXT to exit Installer Display. Press REGEN to return to previous display.
EI Manual
Page 9
Step 1CT - Press NEXT and simultaneously for 5 seconds and release. If
screen in Step 2CT does not appear, the lock on the valve is activated. To unlock press , NEXT, REGEN, in sequence, then press NEXT and simultaneously for 5 seconds and release.
Step 2CT
3 Remaining M /Hour Time
M3
Step 3CT
Step 3CT - Adjust the length of the backwash from 1-20 minutes or OFF using the or buttons.
Press NEXT to go to Step 4CT. Press REGEN to return to previous step.
Step 4CT
Step 4CT - Adjust the length of the regenerant draw from 1-99 minutes or OFF using the or buttons.
Press NEXT to go to Step 5CT. Press REGEN to return to previous step.
Step 5CT
Step 5CT - Adjust the length of the second backwash from 1-20 minutes or OFF using the or buttons.
Press NEXT to go to Step 6CT. Press REGEN to return to previous step.
Step 6CT
Step 6CT - Adjust the length of rinse from 1-20 minutes or OFF using the or
buttons. Press NEXT to go to Step 7CT. Press REGEN to return to previous step.
Step 7CT
Step 7CT - Adjust the length of ll from 0.1-99.9 minutes or OFF. WS2 valves are shipped from the factory with a rell ow control of 2.2 gpm (8.3 lpm). All other control valves are shipped from the factory with a rell ow control of 0.5 gpm (1.9 lpm).
Press NEXT to exit Regeneration Cycle Times. Press REGEN to return to previous step.
Page 10
EI Manual
Conguration Settings
Step 1CS
Step 1CS Press and buttons simultaneously for 5 seconds and release. If screen in Step 2CS does not appear, the lock on the valve is activated. To unlock press , NEXT, REGEN, in sequence, then press and buttons simultaneously for 5 seconds and release. Step 2CS Select 25 for 1 (25 mm), 32 for 1.25 (32 mm), 38 for 1.5 (38 mm), 50L for 2L (50mm) or 50 for 2 (50mm). Press NEXT to go to Step 3CS. Press REGEN to exit Conguration Settings.
Step 2CS
Step 3CS
Step 3CS Press the or buttons to select one of the following: If Volume (M3) is selected the regeneration will occur after the specic volume has been used or on the day override (if selected) whichever comes rst. If 28 is selected the regeneration will occur on the day (1 through 28) selected in Installer Display Settings. The total ow and ow rate user displays and the volume display in Diagnostics will not be shown even if a meter is used. If 28/Volume (M3) is selected the regeneration will occur on the day (1 through 28) selected in Installer Display Settings. If a meter is not used the total ow and ow rate user displays and the volume display in Diagnostics will be shown as 0. If 7 is selected the regeneration will occur on the selected day(s) of the week (see instructions contained in Installer Display Settings). The total ow and ow rate user displays and the volume display in Diagnostics will not be shown even if a meter is used. If 7/Volume (M3) is selected the regeneration will occur on the selected day(s) of the week (see instructions contained in Installer Display Settings). If a meter is not used the total ow and ow rate user displays and the volume display in Diagnostics will be shown as 0. Press NEXT to go to Step 4CS. Press REGEN to return to previous step.
Step 4CS
Step 4CS Press the or buttons to select to regenerate immediately on 0 or at delayed time. Immediately on 0 can only be selected if Volume (M3) was selected in step 3CS and a meter must be installed. Delay is the only option for the other Step 3CS selections. Press NEXT to go to Step 5CS. Press REGEN to return to previous step.
When using the WS2 control valve, the circuit board software must have meter selection choices of 50 and 50L. The WS2 valve must be set for the 50 meter selection during programming. If the software version does not have both the 50 and 50L selections, consult your equipment supplier for a replacement circuit board. When using the WS2L valve with older version software that does not have both 50 and 50L selection choices, the valve must be set to 50 during programming. If a WS2L valve is being used with newer version software that has both 50 and 50L selection choices, the valve must be set for 50L during programming.
EI Manual
Step 5CS
Page 11
Step 5CS Allows selection of one of the following: the Control Valve to act as an alternator; or the Control Valve to have no hard water bypass. Selecting the Control Valve to act as an alternator: NOTE: In step 3CS you must select Volume, Step 4CS select Regeneration Time Option on 0 and in Step 3I select Day Override oFF. Select oFF when feature not used. Select ALTA for the control valve that has the two pin connector labeled DRIVE connected to the alternator valve motor. Select ALTb for the control valve that will not be connected to the alternator valve motor. 1/1.25 2-Way MAV (FF or FM) Conguring the Control Valve for No Hard Water Bypass Operation: nHbP - Selection requires that a connection from a Clack Motorized No Hard Water Bypass Valve (NHBP) is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board. The A port of the NHBP must be connected to the outlet of the control valve. The NHBP will be driven closed before the rst regeneration cycle that is not FILL or SOFTENING or FILTERING, and be driven open after the last regeneration cycle that is not FILL. NOTE: If the control valve is in an error state during regeneration mode the no hard water bypass valve will remain closed until the error is corrected and reset. 1/1.25 3-Way MAV (FF or FM) Conguring the Control Valve for Separate Source Backwash Operation: During programming nHbP must be selected. This selection requires that a connection from a Clack Motorized Alternator Valve (MAV) is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board. The Common port of the MAV must be connected to the inlet of the control valve. The A port will become the inlet for the separate source backwash water supply. The B port will become the inlet for the untreated water supply. The MAV will be driven closed before the rst regeneration cycle that is not FILL or SOFTENING or FILTERING, and be driven open after the last regeneration cycle that is not FILL. NOTE: If the control valve is in an error state during regeneration mode the 3-Way MAV Motorized Alternator Valve will close the B port and keep open the A port until the error is corrected and reset. 1.5 MAV/ 2 MAV (Old Style MAV and REV 2 New Style) Conguring the Control Valve for No Hard Water Bypass Operation: nHbP - Selection requires that a connection from a Clack Motorized Alternator Valve (MAV) is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board. The A port of the MAV must be plugged and the valve outlet connected to the B port. The MAV will be driven closed before the rst regeneration cycle that is not FILL or SOFTENING or FILTERING, and be driven open after the last regeneration cycle that is not FILL. NOTE: If the control valve is in an error state during regeneration mode the no hard water bypass valve will remain closed until the error is corrected and reset. 1.5 3-Way MAV/ 2 MAV (Old Style MAV and REV 2 New Style) Conguring the Control Valve for Separate Source Backwash Operation: During programming nHbP must be selected. This selection requires that a connection from a Clack Motorized Alternator Valve (MAV) is made to the two pin connector labeled ALTERNATOR DRIVE located on the printed circuit board. The Common port of the MAV must be connected to the inlet of the control valve. The A port will become the inlet for the separate source backwash water supply. The B port will become the inlet for the untreated water supply. The MAV will be driven closed before the rst regeneration cycle that is not FILL or SOFTENING or FILTERING, and be driven open after the last regeneration cycle that is not FILL. NOTE: If the control valve is in an error state during regeneration mode the 3-Way MAV Motorized Alternator Valve will close the B port and keep open the A port until the error is corrected and reset. Press NEXT to go to Step 6CS. Press REGEN to return to previous step.
Page 12
Step 6CS
Remaining M /Hour Time
3
EI Manual
Step 6CS Set duration of the special rinse cycle to be performed prior to a valve returning to Service. Selectable from 1-20 minutes or OFF. Only viewed if 50 is set in 2CS, and ALTA or ALTb is set in 5CS. Press NEXT to go to Step 7CS. Press REGEN to return to previous step.
Step 7CS
Step 7CS Selecting the use of an outside signal to initiate a regeneration: Selection only matters if a connection is made to the two pin connector labeled DP SWITCH located on the printed circuit board. Following is an explanation of the options: oFF - feature not used on0 - If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur immediately. dELy - If the dP switch is closed for an accumulative time of 2 minutes a regeneration will occur at the scheduled regeneration time. HoLd - If the dP switch is closed a regeneration will be prevented from occurring. Not viewed if Step 5CS is set to ALTA or ALTb. Press NEXT to exit Conguration Settings. Press REGEN to return to previous step.
EI Manual
Page 13
Page 14
EI Manual
Diagnostics
Step 1D
Step 1D - Press and buttons simultaneously for 5 seconds and release. Then press and buttons simultaneously for 2 seconds and release. If screen in Step 2D does not appear the lock on the valve is activated. To unlock press , NEXT, REGEN, in sequence, then press and buttons simultaneously for 5 seconds and release. Then press and buttons simultaneously for 2 seconds and release.
Step 2D
Step 2D - Display shows the number of days since a regeneration last occurred. Press NEXT to go to Step 3D. Press REGEN to exit Diagnostics.
Step 3D
Step 3D - Display shows the volume of water treated in M3 treated since the last regeneration. If Volume (M3), 28/Volume (M3), or 7/Volume (M3) was selected in Step 3CS and no meter is installed this display will read 0. Press NEXT to go to Step 4D. Press REGEN to return to previous step.
Step 4D
Step 4D - Display shows the days in service since start up. Press NEXT to go to Step 5D. Press REGEN to return to previous step.
Step 5D
Step 5D - Display shows the total number of regeneration cycles since start up. Press NEXT to exit Diagnostics. Press REGEN to return to previous step.
EI Manual
Page 15
Page 16
EI Manual
Revision History:
5/29/08 Moved common valve drawings to V3435 WS1.5/2L Drawing and Service Manual. 7/08/08 PAGE 8: Added Softening or Filtering selection (Step 2CT). PAGE 9: Added 32mm option (Step 2CS). PAGE 8: Added special Rinse cycle (Step 2CT). 8/01/08 PAGE 6: Updated display for Step2I PAGE 7: Updated display for Step2I and Step3I PAGE 8: Updated display for Step2CT PAGE 9: Step2CS: Select 25 for 1 (25 mm), 32 for 1.25 (32 mm), 38 for 1.5 (38 mm), 50L for 2L (50mm) or 50 for 2 (50mm). PAGE 10: Updated display for Step7CS 10/13/08 PAGE 10: Revised No Hard Water Bypass instructions. PAGE 12: Added MAV instructions.