Vous êtes sur la page 1sur 4

DIGITAL PRESSURE TRANSMITTER DTM

28

Features
Compact and robust stainless steel assembly 1.4435 (316L) Piezoresistive measuring element Gauge, absolute or sealed gauge Standard DIN pressure ranges from 0100 mbar to 01000 bar Calibration available for all common pressure units Complies with the EMC directive 89/336/EEC High reliability Short delivery time Customized versions due to modular assembly Reverse polarity and short circuit protected Media temperature up to 150 C (optional) Interface RS232C or RS485

Typical applications Drucktransmitter mit


Machine installations piezoresitivem Messelement. Industrial process control Heating and ventilation Environmental monitoring Food industry Mobile hydraulics Test and calibration systems Gas density control

- feel the Dif ference

Specifications
Pressure range Overpressure [bar] 0.1 0.5 3 bar > 0.5 2 3 x FS
(min. 3 bar)

> 2 25 3 x FS

> 25 600 3 x FS
(max. 850 bar, optional 1500 bar)

> 600 1000 1500 bar

Burst pressure Accuracy1) Thermal shift Zero Span

[bar] [ % FS] [ % FS/C] 070C -2585C 070C -2585C

> 200 0.25 0.06 0.08 0.015 0.02 < 4 mbar

> 200 0.1 0.03 0.04 0.015 0.02 < 4 mbar

> 200 0.1 0.015 0.02 0.015 0.02 < 0.2% FS

> 850
(optional 1500 bar)

1500 0.1 0.015 0.02 0.015 0.02 < 0.2% FS

0.1 0.015 0.02 0.015 0.02 < 0.2% FS

Long term stability (1 year)


1)

Zero based non-conformity according to DIN 16086, including hysteresis and repeatability

Interface Power supply Current consumption Circuit diagram


P RS232C

RS232C 530 V DC < 7 mA


+Vin GND RxD T xD GND +Vin

RS485 530 V DC < 7 mA


P RS485

GND +RS485 - RS485

Resolution Integration time Identification

< 0.01 % FS 1 ms 20 s, adjustable

< 0.01 % FS 1 ms 20 s, adjustable

Each DTM has a serial number and a customer programmable mark Materials

Process connection, diaphragm, housing Seals (standard)

Stainless steel 1.4435 (316L) Viton

(other materials on request) (other materials see ordering information)

Electromagnetic compability
Standard Emission: EN 50081-1:1992 EN 55022:1994 Immunity: EN 50082-2:1995 EN 61000-4-2:1995 ENV 50140:1993 ENV 50204:1995 EN 61000-4-4:1995 ENV 50141:1993 Generic emission standard Emission, class B Level Typical interferences

Generic immunity Electrostatic discharge Radiated electro-magnetic field Radiated electro-magnetic field (GSM) Fast transients (burst) Conducted radio-frequency

4kV contact, 8kV air 10V/m, 80-1000 MHz, 80% AM 1kHz 10V/m, 950 MHz, 200Hz on/off 2 kV 10V, 0.15-80 MHz, 80% AM 1kHz

Cellular phones, radio sets Digital portable phones Motors, valves Cellular phones, radio sets

The pressure transmitter DTM fulfill the emission and immunity requirements described in the EMC directive 89/336/EEC.

Ordering Information
Type Pressure type DTM Gauge Absolute Sealed gauge 0100 mbar 0160 mbar 0250 mbar 0400 mbar 0600 mbar 01.0 bar 01.6 bar 02.5 bar 04.0 bar 06.0 bar 010 bar 016 bar 025 bar 040 bar 060 bar 0100 bar 0160 bar 0250 bar 0400 bar 0600 bar 01000 bar Special calibration G 1/4 female G 1/4 M G 1/4 M, Manometer DIN 16288 G 1/2 M G 1/2 M, frontal diaphragm G 1/2 M, flush diaphragm G 1/2 M, Manometer DIN 16288 1/4 NPT M 1/2 NPT M Special process connection Connector DIN 43650 (screwed on) 3) Connector Binder 723, 5-pin 3) Connector MIL C26482, (10-6) 3) PE cable 4) 5) PUR cable 4) Teflon cable 4) Special electrical connection RS232C RS485 0.25% FS (for pressure ranges 500 mbar) 0.1 % FS (for pressure ranges > 500 mbar) Compensated 070C (media temperature 0 80C) Compensated -2585C (media temperature -25100C) Compensated -2585C (media temperature -25150C) Special temperature range Throttle 2) Electronics packed in gel: Gauge pressure Absolute and sealed gauge pressure Temperature measurement (ambient temperature) Special oil filling: ASEOL Food Halocarbon Seals: EPDM Kalrez Special options
5)

28 X . XXXX . XXXX . XX . XXX


28 1 2 3 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 99 00 11 12 13 14 15 16 10 19 99 IP 65 IP 67 IP 40 IP 67 IP 67 IP 67 01 03 06 13 15 21 99 61 62

Pressure range

3 3 3 3 3 3 3 3 (Fig. 1) (Fig. 2) (Fig. 3) (Fig. 4) (Fig. 5) (Fig. 6) (Fig. 7) (Fig. 8) (Fig. 10) (Fig. 11) (Fig. 13) (Fig. 14) (Fig. 14) (Fig. 14)

Process connection

Electrical connection

Interface

Accuray

1 2

Temperature range

0 1 2 9 A C D E G H S T Z

Options

2) 3)

Available only with fig. 2, fig. 4 or fig. 7 Cable socket connector not included 4) Please specify the required cable length

Suitable for drinking water (food approved)

Pressure Connection

Dimensions
Version for media temperature up to 100C

Electrical Connection
46.5

Pin RS232C RS485 1 +Vin 2 RxD 3 GND


TxD

G 1/4 F

SW27

24

+Vin +RS485 GND


-RS485

32,5

Fig. 1

Fig. 10
12

3 1 2

L = 94 mm for connector DIN 43650 (Fig. 10)


G 1/4 M SW27

32,5 16

Fig. 2
Version for media temperature up to 150C

G 1/4 M

Fig. 11
24

68

SW27

35,5 13,5

Fig. 3
L

Cable socket connector


3 2 1 4 5

G 1/2 M

SW27

L = 121 mm for connector DIN 43650 (Fig. 10) Pin RS232C RS485

32,5
20,5

Fig. 4

74.5
G 1/2 M 18,4 SW27

1 2 3 4

RxD TxD +Vin GND

+RS485 - RS485 +Vin GND

Fig. 12 Fig. 5
Cable socket connector
A B F E D

34,5

19,5

G 1/2 M

18,4

SW27

33,5

Fig. 6
62.5

Pin RS232C RS485 A B C D +Vin GND RxD TxD +Vin GND +RS485 - RS485

25
G 1/2 M

Fig. 13
SW27

43

Fig. 7

Colour RS232C RS485 white yellow brown green +Vin GND RxD TxD +Vin GND +RS485 - RS485

17
1/2 NPT M

PG9
SW27

Fig. 14

31,5

Fig. 8

Vous aimerez peut-être aussi